Skip to content

Compare versions of (EU) 134/2014

Supplementing Regulation (EU) No 168/2013 of the European Parliament and of the Council with regard to environmental and propulsion unit performance requirements and amending Annex V thereof Text with EEA relevance

30 changed · 603 added · 452 deleted
Gerekce (preamble)deleted
2014R0134 — EN — 16.10.2016 — 001.001 This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document ►B | COMMISSION DELEGATED REGULATION (EU) No 134/2014 of 16 December 2013 supplementing Regulation (EU) No 168/2013 of the European Parliament and of the Council with regard to environmental and propulsion unit performance requirements and amending Annex V thereof (Text with EEA relevance) (OJ L 053 21.2.2014, p. 1) Amended by: Official Journal No | page | date ►M1 | COMMISSION DELEGATED REGULATION (EU) 2016/1824 of 14 July 2016 | L 279 | 1 | 15.10.2016
2.changed
It shall apply from 1 January 2016. This Regulation shall be binding in its entirety and directly applicable in all Member States. LIST OF ANNEXES Annex Number | Annex title I | List of UNECE regulations which apply on a compulsory basis II | Test type I requirements: tailpipe emissions after cold start III | Test type II requirements: tailpipe emissions at (increased) idle and free acceleration IV | Test type III requirements: emissions of crankcase gases V | Test type IV requirements: evaporative emissions VI | Test type V requirements: durability of pollution-control devices VII | Test type VII requirements on energy efficiency: CO2 emissions, fuel consumption, electric energy consumption and electric range VIII | Test type VIII requirements: OBD environmental tests IX | Test type IX requirements: sound level X | Testing procedures and technical requirements as regards propulsion unit performance XI | Vehicle propulsion family with regard to environmental performance demonstration testing XII | Amendment of Part A of Annex V to Regulation (EU) No 168/2013
LIST OF ANNEXESdeleted
Annex Number | Annex title I | List of UNECE regulations which apply on a compulsory basis II | Test type I requirements: tailpipe emissions after cold start III | Test type II requirements: tailpipe emissions at (increased) idle and free acceleration IV | Test type III requirements: emissions of crankcase gases V | Test type IV requirements: evaporative emissions VI | Test type V requirements: durability of pollution-control devices VII | Test type VII requirements on energy efficiency: CO2 emissions, fuel consumption, electric energy consumption and electric range VIII | Test type VIII requirements: OBD environmental tests IX | Test type IX requirements: sound level X | Testing procedures and technical requirements as regards propulsion unit performance XI | Vehicle propulsion family with regard to environmental performance demonstration testing XII | Amendment of Part A of Annex V to Regulation (EU) No 168/2013
Test type I requirements: tailpipe emissions afte…added
Appendix Number | Appendix title 1 | Symbols used in Annex II 2 | Reference fuels 3 | Chassis dynamometer system 4 | Exhaust dilution system 5 | Classification of equivalent inertia mass and running resistance 6 | Driving cycles for type I tests 7 | Road tests of L-category vehicles equipped with one wheel on the driven axle or with twinned wheels for the determination of test bench settings 8 | Road tests of L-category vehicles equipped with two or more wheels on the powered axle for the determination of test bench settings 9 | Explanatory note on the gearshift procedure for a type I test 10 | Type-approval tests of a replacement pollution-control device type for L-category vehicles as a separate technical unit 11 | Type I test procedure for hybrid L-category vehicles 12 | Type I test procedure for L-category vehicles fuelled with LPG, NG/biomethane, flex fuel H2NG or hydrogen 13 | Type I test procedure for L-category vehicles equipped with a periodically regenerating system
ANNEX IIdeleted
Appendix Number | Appendix title 1 | Symbols used in Annex II 2 | Reference fuels 3 | Chassis dynamometer system 4 | Exhaust dilution system 5 | Classification of equivalent inertia mass and running resistance 6 | Driving cycles for type I tests 7 | Road tests of L-category vehicles equipped with one wheel on the driven axle or with twinned wheels for the determination of test bench settings 8 | Road tests of L-category vehicles equipped with two or more wheels on the powered axle for the determination of test bench settings 9 | Explanatory note on the gearshift procedure for a type I test 10 | Type-approval tests of a replacement pollution-control device type for L-category vehicles as a separate technical unit 11 | Type I test procedure for hybrid L-category vehicles 12 | Type I test procedure for L-category vehicles fuelled with LPG, NG/biomethane, flex fuel H2NG or hydrogen 13 | Type I test procedure for L-category vehicles equipped with a periodically regenerating system
1.1.added
This Annex sets out the procedure for type I testing, as referred to in Part A of Annex V to Regulation (EU) No 168/2013.
1. Introductiondeleted
1.1. This Annex sets out the procedure for type I testing, as referred to in Part A of Annex V to Regulation (EU) No 168/2013. 1.2. This Annex provides a harmonised method for the determination of the levels of gaseous pollutant emissions and particulate matter, the emissions of carbon dioxide and is referred to in Annex VII to determine the fuel consumption, energy consumption and electric range of the L-category vehicle within the scope of Regulation (EU) No 168/2013 that are representative for real world vehicle operation. 1.1.1. The ‘WMTC stage 1’ was introduced in EU type-approval legislation in 2006, which allowed manufacturers from then on to demonstrate the emission performance of the L3e motorcycle type by using the world harmonised motorcycle test cycle (WMTC) set out in UN GTR No 2 as alternative type I test to the use of the conventional European Driving Cycle (EDC) set out in Chapter 5 of Directive 97/24/EC. 1.1.2. The ‘WMTC stage 2’ is equal to ‘WMTC stage 1’ with additional enhancements in the area of gear shift prescriptions and shall be used as compulsory type I test to approve Euro 4 compliant (sub-)categories L3e, L4e, L5e-A and L7e-A vehicles. 1.1.3. The ‘revised WMTC’ or ‘WMTC stage 3’ is equal to ‘WMTC stage 2’ for L3e motorcycles, but contains also custom-tailored driving cycles for all other (sub-) category vehicles, used as type I test to approve Euro 5 compliant L-category vehicles. 1.2. The results may form the basis for limiting gaseous pollutants…
1.2.added
This Annex provides a harmonised method for the determination of the levels of gaseous pollutant emissions and particulate matter, the emissions of carbon dioxide and is referred to in Annex VII to determine the fuel consumption, energy consumption and electric range of the L-category vehicle within the scope of Regulation (EU) No 168/2013 that are representative for real world vehicle operation.
2. General requirementsdeleted
2.1. The components liable to affect the emission of gaseous pollutants, carbon dioxide emissions and fuel consumption shall be so designed, constructed and assembled as to enable the vehicle in normal use, despite the vibration to which it may be subjected, to comply with the provisions of this Annex. Note 1: The symbols used in Annex II are summarised in Appendix 1. 2.2. Any hidden strategy that ‘optimises’ the powertrain of the vehicle running the relevant emission laboratory test cycle in an advantageous way, reducing tailpipe emissions and running significantly differently under real-world conditions, is considered a defeat strategy and is prohibited, unless the manufacturer has documented and declared it to the satisfaction of the approval authority.
1.1.1.added
The ‘WMTC stage 1’ was introduced in EU type-approval legislation in 2006, which allowed manufacturers from then on to demonstrate the emission performance of the L3e motorcycle type by using the world harmonised motorcycle test cycle (WMTC) set out in UN GTR No 2 as alternative type I test to the use of the conventional European Driving Cycle (EDC) set out in Chapter 5 of Directive 97/24/EC.
1.1.2.added
The ‘WMTC stage 2’ is equal to ‘WMTC stage 1’ with additional enhancements in the area of gear shift prescriptions and shall be used as compulsory type I test to approve Euro 4 compliant (sub-)categories L3e, L4e, L5e-A and L7e-A vehicles.
1.1.3.added
The ‘revised WMTC’ or ‘WMTC stage 3’ is equal to ‘WMTC stage 2’ for L3e motorcycles, but contains also custom-tailored driving cycles for all other (sub-) category vehicles, used as type I test to approve Euro 5 compliant L-category vehicles.
1.2.added
The results may form the basis for limiting gaseous pollutants, carbon dioxide and for the fuel consumption, energy consumption and electric range indicated by the manufacturer within the environmental performance type-approval procedures.
2.1.added
The components liable to affect the emission of gaseous pollutants, carbon dioxide emissions and fuel consumption shall be so designed, constructed and assembled as to enable the vehicle in normal use, despite the vibration to which it may be subjected, to comply with the provisions of this Annex. Note 1: The symbols used in Annex II are summarised in Appendix 1.
2.2.added
Any hidden strategy that ‘optimises’ the powertrain of the vehicle running the relevant emission laboratory test cycle in an advantageous way, reducing tailpipe emissions and running significantly differently under real-world conditions, is considered a defeat strategy and is prohibited, unless the manufacturer has documented and declared it to the satisfaction of the approval authority.
4.5.3. Exhaust gas measurement systemchanged
4.5.3.1. | The gas-collection device shall be a closed-type device that can collect all exhaust gases at the vehicle exhaust outlets on condition that it satisfies the backpressure condition of ± 125 mm H2O. An open system may be used if it is confirmed that all the exhaust gases are collected. The gas collection shall be such that there is no condensation which could appreciably modify the nature of exhaust gases at the test temperature. An example of a gas-collection device is illustrated in Figure 1-2: Figure 1-2 Equipment for sampling the gases and measuring their volume 4.5.3.2. | A connecting tube shall be placed between the device and the exhaust gas sampling system. This tube and the device shall be made of stainless steel, or of some other material which does not affect the composition of the gases collected and which withstands the temperature of these gases. 4.5.3.3. | A heat exchanger capable of limiting the temperature variation of the diluted gases in the pump intake to ± 5 K shall be in operation throughout the test. This exchanger shall be equipped with a preheating system capable of bringing the exchanger to its operating temperature (with the tolerance of ± 5 K) before the test begins. 4.5.3.4. | A positive displacement pump shall be used to draw in the diluted exhaust mixture. This pump shall be equipped with a motor with several strictly controlled uniform speeds. The pump capacity shall be large enough to ensure the intake of the exhaust gases. A device using a critical-flow venturi (CFV) may also be used. 4.5.3.5. | A device (T) shall be used for the continuous recording of the temperature of the diluted exhaust mixture entering the pump. 4.5.3.6. | Two gauges shall be used, the first to ensure the pressure depression of the dilute exhaust mixture entering the pump relative to atmospheric pressure, and the second to measure the dynamic pressure variation of the positive displacement pump. 4.5.3.7. | A probe shall be located near to, but outside, the gas-collecting device, to collect samples of the dilution air stream through a pump, a filter and a flow meter at constant flow rates throughout the test. 4.5.3.8. | A sample probe pointed upstream into the dilute exhaust mixture flow, upstream of the positive displacement pump, shall be used to collect samples of the dilute exhaust mixture through a pump, a filter and a flow meter at constant flow rates throughout the test. The minimum sample flow rate in the sampling devices shown in Figure 1-2 and in point 4.5.3.7. shall be at least 150 litre/hour. 4.5.3.9. | Three-way valves shall be used on the sampling system described in points 4.5.3.7. and 4.5.3.8. to direct the samples either to their respective bags or to the outside throughout the test. 4.5.3.10. | Gas-tight collection bags 4.5.3.10.1. For dilution air and dilute exhaust mixture the collection bags shall be of sufficient capacity not to impede normal sample flow and shall not change the nature of the pollutants concerned. 4.5.3.10.2. The bags shall have an automatic self-locking device and shall be easily and tightly fastened either to the sampling system or the analysing system at the end of the test. 4.5.3.10.1. | For dilution air and dilute exhaust mixture the collection bags shall be of sufficient capacity not to impede normal sample flow and shall not change the nature of the pollutants concerned. 4.5.3.10.2. | The bags shall have an automatic self-locking device and shall be easily and tightly fastened either to the sampling system or the analysing system at the end of the test. 4.5.3.11. | A revolution counter shall be used to count the revolutions of the positive displacement pump throughout the test. Note 2: Attention shall be paid to the connecting method and the material or configuration of the connecting parts, because each section (e.g. the adapter and the coupler) of the sampling system can become very hot. If the measurement cannot be performed normally due to heat damage to the sampling system, an auxiliary cooling device may be used as long as the exhaust gases are not affected. Note 3: With open type devices, there is a risk of incomplete gas collection and gas leakage into the test cell. There shall be no leakage throughout the sampling period. Note 4: If a constant volume sampler (CVS) flow rate is used throughout the test cycle that includes low and high speeds all in one (i.e. part 1, 2 and 3 cycles), special attention shall be paid to the higher risk of water condensation in the high speed range. 4.5.3.12. | Particulate mass emissions measurement equipment4.5.3.12.1 Specification 4.5.3.12.1.1. System overview 4.5.3.12.1.1.1. The particulate sampling unit shall consist of a sampling probe located in the dilution tunnel, a particle transfer tube, a filter holder, a partial-flow pump, and flow rate regulators and measuring units. 4.5.3.12.1.1.2. It is recommended that a particle size pre-classifier (e.g. cyclone or impactor) be employed upstream of the filter holder. However, a sampling probe, used as an appropriate size-classification device such as that shown in Figure 1-6, is acceptable. 4.5.3.12.1.2. General requirements 4.5.3.12.1.2.1. The sampling probe for the test gas flow for particulates shall be so arranged within the dilution tract that a representative sample gas flow can be taken from the homogeneous air/exhaust mixture. 4.5.3.12.1.2.2. The particulate sample flow rate shall be proportional to the total flow of diluted exhaust gas in the dilution tunnel to within a tolerance of ±5 percent of the particulate sample flow rate. 4.5.3.12.1.2.3. The sampled dilute exhaust gas shall be maintained at a temperature below 325,2 K (52 °C) within 20 cm upstream or downstream of the particulate filter face, except in the case of a regeneration test, where the temperature shall be below 465,2 K (192 °C). 4.5.3.12.1.2.4. The particulate sample shall be collected on a single filter mounted in a holder in the sampled diluted exhaust gas flow 4.5.3.12.1.2.5. All parts of the dilution system and the sampling system from the exhaust pipe up to the filter holder which are in contact with raw and diluted exhaust gas shall be designed to minimise deposition or alteration of the particulates. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects. 4.5.3.12.1.2.6. If it is not possible to compensate for variations in the flow rate, provision shall be made for a heat exchanger and a temperature control device as specified in Appendix 4 so as to ensure that the flow rate in the system is constant and the sampling rate accordingly proportional. 4.5.3.12.1.3. Specific requirements 4.5.3.12.1.3.1. Particulate matter (PM) sampling probe 4.5.3.12.1.3.1.1. The sample probe shall deliver the particle-size classification performance described in point 4.5.3.12.1.3.1.4. It is recommended that this performance be achieved by the use of a sharp-edged, open-ended probe facing directly in the direction of flow, plus a pre-classifier (cyclone impactor, etc.). An appropriate sampling probe, such as that indicated in Figure 1-1, may alternatively be used provided it achieves the pre-classification performance described in point 4.5.3.12.1.3.1.4. 4.5.3.12.1.3.1.2. The sample probe shall be installed near the tunnel centreline between ten and 20 tunnel diameters downstream of the exhaust gas inlet to the tunnel and have an internal diameter of at least 12 mm. If more than one simultaneous sample is drawn from a single sample probe, the flow drawn from that probe shall be split into identical sub-flows to avoid sampling artefacts. If multiple probes are used, each probe shall be sharp-edged, open-ended and facing directly into the direction of flow. Probes shall be equally spaced at least 5 cm apart around the central longitudinal axis of the dilution tunnel. 4.5.3.12.1.3.1.3. The distance from the sampling tip to the filter mount shall be at least five probe diameters, but shall not exceed 1 020 mm. 4.5.3.12.1.3.1.4. The pre-classifier (e.g. cyclone, impactor, etc.) shall be located upstream of the filter holder assembly. The pre-classifier 50 percent cut point particle diameter shall be between 2.5 μm and 10 μm at the volumetric flow rate selected for sampling particulate mass emissions. The pre-classifier shall allow at least 99 percent of the mass concentration of 1 μm particles entering the pre-classifier to pass through the exit of the pre-classifier at the volumetric flow rate selected for sampling particulate mass emissions. However, a sampling probe, used as an appropriate size-classification device, such as that shown in Figure 1-6, is acceptable as an alternative to a separate pre-classifier. 4.5.3.12.1.3.2. Sample pump and flow meter 4.5.3.12.1.3.2.1. The sample gas flow measurement unit shall consist of pumps, gas flow regulators and flow measuring units. 4.5.3.12.1.3.2.2. The temperature of the gas flow in the flow meter may not fluctuate by more than ±3 K, except during regeneration tests on vehicles equipped with periodically regenerating after-treatment devices. In addition, the sample mass flow rate shall remain proportional to the total flow of diluted exhaust gas to within a tolerance of ± 5 percent of the particulate sample mass flow rate. Should the volume of flow change unacceptably as a result of excessive filter loading, the test shall be stopped. When the test is repeated, the rate of flow shall be decreased. 4.5.3.12.1.3.3. Filter and filter holder 4.5.3.12.1.3.3.1. A valve shall be located downstream of the filter in the direction of flow. The valve shall be responsive enough to open and close within one second of the start and end of the test. 4.5.3.12.1.3.3.2. It is recommended that the mass collected on the 47 mm diameter filter (Pe) is ≥ 20 μg and that the filter loading is maximised in line with the requirements of points 4.5.3.12.1.2.3. and 4.5.3.12.1.3.3. 4.5.3.12.1.3.3.3. For a given test, the gas filter face velocity shall be set to a single value within the range 20 cm/s to 80 cm/s, unless the dilution system is being operated with sampling flow proportional to CVS flow rate. 4.5.3.12.1.3.3.4. Fluorocarbon coated glass fibre filters or fluorocarbon membrane filters are required. All filter types shall have a 0,3 μm DOP (di-octylphthalate) or PAO (poly-alpha-olefin) CS 68649-12-7 or CS 68037-01-4 collection efficiency of at least 99 percent at a gas filter face velocity of 5,33 cm/s. 4.5.3.12.1.3.3.5. The filter holder assembly shall be of a design that provides an even flow distribution across the filter stain area. The filter stain area shall be at least 1 075 mm2. 4.5.3.12.1.3.4. Filter weighing chamber and balance 4.5.3.12.1.3.4.1. The microgram balance used to determine the weight of a filter shall have a precision (standard deviation) of 2 μg and resolution of 1 μg or better. It is recommended that the microbalance be checked at the start of each weighing session by weighing one reference weight of 50 mg. This weight shall be weighed three times and the average result recorded. The weighing session and balance are considered valid if the average result of the weighing is within ± 5 μg of the result from the previous weighing session. The weighing chamber (or room) shall meet the following conditions during all filter conditioning and weighing operations: — Temperature maintained at 295,2 ± 3 K (22 ± 3 °C); — Relative humidity maintained at 45 ± 8 percent; — Dew point maintained at 282,7 ± 3 K (9,5 ± 3 °C). It is recommended that temperature and humidity conditions be recorded along with sample and reference filter weights. 4.5.3.12.1.3.4.2. Buoyancy correctionAll filter weights shall be corrected for filter buoyancy in air. The buoyancy correction depends on the density of the sample filter medium, the density of air, and the density of the calibration weight used to calibrate the balance. The density of the air is dependent on the pressure, temperature and humidity. It is recommended that the temperature and dew point of the weighing environment be controlled to 295,2 K ± 1 K (22 °C ± 1 °C) and 282,7 ± 1 K (9,5 ± 1 °C) respectively. However, the minimum requirements stated in point 4.5.3.12.1.3.4.1. will also result in an acceptable correction for buoyancy effects. The correction for buoyancy shall be applied as follows: Equation 2-1: where: mcorr = PM mass corrected for buoyancy muncorr = PM mass uncorrected for buoyancy ρair = density of air in balance environment ρweight = density of calibration weight used to span balance ρmedia = density of PM sample medium (filter) with filter medium Teflon coated glass fibre (e.g. TX40): ρmedia = 2,300 kg/m3 ρair can be calculated as follows: Equation 2-2: where: Pabs = absolute pressure in balance environment Mmix = molar mass of air in balance environment (28,836 gmol-1) R = molar gas constant (8,314 Jmol-1K-1) Tamb = absolute ambient temperature of balance environment The chamber (or room) environment shall be free of any ambient contaminants (such as dust) that would settle on the particulate filters during their stabilisation. Limited deviations from weighing room temperature and humidity specifications shall be allowed provided their total duration does not exceed 30 minutes in any one filter conditioning period. The weighing room shall meet the required specifications prior to personal entrance into the weighing room. No deviations from the specified conditions are permitted during the weighing operation. 4.5.3.12.1.3.4.3. The effects of static electricity shall be nullified. This may be achieved by grounding the balance through placement on an antistatic mat and neutralisation of the particulate filters prior to weighing using a Polonium neutraliser or a device of similar effect. Alternatively, nullification of static effects may be achieved through equalisation of the static charge. 4.5.3.12.1.3.4.4. A test filter shall be removed from the chamber no earlier than an hour before the test begins. 4.5.3.12.1.4. Recommended system description Figure 1-3 is a schematic drawing of the recommended particulate sampling system. Since various configurations can produce equivalent results, exact conformity with this figure is not required. Additional components such as instruments, valves, solenoids, pumps and switches may be used to provide additional information and coordinate the functions of component systems. Further components that are not needed to maintain accuracy with other system configurations may be excluded if their exclusion is based on good engineering judgment. Figure 1-3 Particulate sampling system A sample of the diluted exhaust gas is taken from the full flow dilution tunnel (DT) through the particulate sampling probe (PSP) and the particulate transfer tube (PTT) by means of the pump (P). The sample is passed through the particle size pre-classifier (PCF) and the filter holders (FH) that contain the particulate sampling filters. The flow rate for sampling is set by the flow controller (FC). 4.5.3.12.1.1.1. | The particulate sampling unit shall consist of a sampling probe located in the dilution tunnel, a particle transfer tube, a filter holder, a partial-flow pump, and flow rate regulators and measuring units. 4.5.3.12.1.1.2. | It is recommended that a particle size pre-classifier (e.g. cyclone or impactor) be employed upstream of the filter holder. However, a sampling probe, used as an appropriate size-classification device such as that shown in Figure 1-6, is acceptable. 4.5.3.12.1.2.1. | The sampling probe for the test gas flow for particulates shall be so arranged within the dilution tract that a representative sample gas flow can be taken from the homogeneous air/exhaust mixture. 4.5.3.12.1.2.2. | The particulate sample flow rate shall be proportional to the total flow of diluted exhaust gas in the dilution tunnel to within a tolerance of ±5 percent of the particulate sample flow rate. 4.5.3.12.1.2.3. | The sampled dilute exhaust gas shall be maintained at a temperature below 325,2 K (52 °C) within 20 cm upstream or downstream of the particulate filter face, except in the case of a regeneration test, where the temperature shall be below 465,2 K (192 °C). 4.5.3.12.1.2.4. | The particulate sample shall be collected on a single filter mounted in a holder in the sampled diluted exhaust gas flow 4.5.3.12.1.2.5. | All parts of the dilution system and the sampling system from the exhaust pipe up to the filter holder which are in contact with raw and diluted exhaust gas shall be designed to minimise deposition or alteration of the particulates. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects. 4.5.3.12.1.2.6. | If it is not possible to compensate for variations in the flow rate, provision shall be made for a heat exchanger and a temperature control device as specified in Appendix 4 so as to ensure that the flow rate in the system is constant and the sampling rate accordingly proportional. 4.5.3.12.1.3.1.1. | The sample probe shall deliver the particle-size classification performance described in point 4.5.3.12.1.3.1.4. It is recommended that this performance be achieved by the use of a sharp-edged, open-ended probe facing directly in the direction of flow, plus a pre-classifier (cyclone impactor, etc.). An appropriate sampling probe, such as that indicated in Figure 1-1, may alternatively be used provided it achieves the pre-classification performance described in point 4.5.3.12.1.3.1.4. 4.5.3.12.1.3.1.2. | The sample probe shall be installed near the tunnel centreline between ten and 20 tunnel diameters downstream of the exhaust gas inlet to the tunnel and have an internal diameter of at least 12 mm. If more than one simultaneous sample is drawn from a single sample probe, the flow drawn from that probe shall be split into identical sub-flows to avoid sampling artefacts. If multiple probes are used, each probe shall be sharp-edged, open-ended and facing directly into the direction of flow. Probes shall be equally spaced at least 5 cm apart around the central longitudinal axis of the dilution tunnel. 4.5.3.12.1.3.1.3. | The distance from the sampling tip to the filter mount shall be at least five probe diameters, but shall not exceed 1 020 mm. 4.5.3.12.1.3.1.4. | The pre-classifier (e.g. cyclone, impactor, etc.) shall be located upstream of the filter holder assembly. The pre-classifier 50 percent cut point particle diameter shall be between 2.5 μm and 10 μm at the volumetric flow rate selected for sampling particulate mass emissions. The pre-classifier shall allow at least 99 percent of the mass concentration of 1 μm particles entering the pre-classifier to pass through the exit of the pre-classifier at the volumetric flow rate selected for sampling particulate mass emissions. However, a sampling probe, used as an appropriate size-classification device, such as that shown in Figure 1-6, is acceptable as an alternative to a separate pre-classifier. 4.5.3.12.1.3.2.1. | The sample gas flow measurement unit shall consist of pumps, gas flow regulators and flow measuring units. 4.5.3.12.1.3.2.2. | The temperature of the gas flow in the flow meter may not fluctuate by more than ±3 K, except during regeneration tests on vehicles equipped with periodically regenerating after-treatment devices. In addition, the sample mass flow rate shall remain proportional to the total flow of diluted exhaust gas to within a tolerance of ± 5 percent of the particulate sample mass flow rate. Should the volume of flow change unacceptably as a result of excessive filter loading, the test shall be stopped. When the test is repeated, the rate of flow shall be decreased. 4.5.3.12.1.3.3.1. | A valve shall be located downstream of the filter in the direction of flow. The valve shall be responsive enough to open and close within one second of the start and end of the test. 4.5.3.12.1.3.3.2. | It is recommended that the mass collected on the 47 mm diameter filter (Pe) is ≥ 20 μg and that the filter loading is maximised in line with the requirements of points 4.5.3.12.1.2.3. and 4.5.3.12.1.3.3. 4.5.3.12.1.3.3.3. | For a given test, the gas filter face velocity shall be set to a single value within the range 20 cm/s to 80 cm/s, unless the dilution system is being operated with sampling flow proportional to CVS flow rate. 4.5.3.12.1.3.3.4. | Fluorocarbon coated glass fibre filters or fluorocarbon membrane filters are required. All filter types shall have a 0,3 μm DOP (di-octylphthalate) or PAO (poly-alpha-olefin) CS 68649-12-7 or CS 68037-01-4 collection efficiency of at least 99 percent at a gas filter face velocity of 5,33 cm/s. 4.5.3.12.1.3.3.5. | The filter holder assembly shall be of a design that provides an even flow distribution across the filter stain area. The filter stain area shall be at least 1 075 mm2. 4.5.3.12.1.3.4.1. | The microgram balance used to determine the weight of a filter shall have a precision (standard deviation) of 2 μg and resolution of 1 μg or better. It is recommended that the microbalance be checked at the start of each weighing session by weighing one reference weight of 50 mg. This weight shall be weighed three times and the average result recorded. The weighing session and balance are considered valid if the average result of the weighing is within ± 5 μg of the result from the previous weighing session. The weighing chamber (or room) shall meet the following conditions during all filter conditioning and weighing operations: — Temperature maintained at 295,2 ± 3 K (22 ± 3 °C); — Relative humidity maintained at 45 ± 8 percent; — Dew point maintained at 282,7 ± 3 K (9,5 ± 3 °C). It is recommended that temperature and humidity conditions be recorded along with sample and reference filter weights. 4.5.3.12.1.3.4.2. | Buoyancy correctionAll filter weights shall be corrected for filter buoyancy in air. The buoyancy correction depends on the density of the sample filter medium, the density of air, and the density of the calibration weight used to calibrate the balance. The density of the air is dependent on the pressure, temperature and humidity. It is recommended that the temperature and dew point of the weighing environment be controlled to 295,2 K ± 1 K (22 °C ± 1 °C) and 282,7 ± 1 K (9,5 ± 1 °C) respectively. However, the minimum requirements stated in point 4.5.3.12.1.3.4.1. will also result in an acceptable correction for buoyancy effects. The correction for buoyancy shall be applied as follows: Equation 2-1: where: mcorr = PM mass corrected for buoyancy muncorr = PM mass uncorrected for buoyancy ρair = density of air in balance environment ρweight = density of calibration weight used to span balance ρmedia = density of PM sample medium (filter) with filter medium Teflon coated glass fibre (e.g. TX40): ρmedia = 2,300 kg/m3 ρair can be calculated as follows: Equation 2-2: where: Pabs = absolute pressure in balance environment Mmix = molar mass of air in balance environment (28,836 gmol-1) R = molar gas constant (8,314 Jmol-1K-1) Tamb = absolute ambient temperature of balance environment The chamber (or room) environment shall be free of any ambient contaminants (such as dust) that would settle on the particulate filters during their stabilisation. Limited deviations from weighing room temperature and humidity specifications shall be allowed provided their total duration does not exceed 30 minutes in any one filter conditioning period. The weighing room shall meet the required specifications prior to personal entrance into the weighing room. No deviations from the specified conditions are permitted during the weighing operation. mcorr | = | PM mass corrected for buoyancy muncorr | = | PM mass uncorrected for buoyancy ρair | = | density of air in balance environment ρweight | = | density of calibration weight used to span balance ρmedia | = | density of PM sample medium (filter) with filter medium Teflon coated glass fibre (e.g. TX40): ρmedia = 2,300 kg/m3 Pabs | = | absolute pressure in balance environment Mmix | = | molar mass of air in balance environment (28,836 gmol-1) R | = | molar gas constant (8,314 Jmol-1K-1) Tamb | = | absolute ambient temperature of balance environment 4.5.3.12.1.3.4.3. | The effects of static electricity shall be nullified. This may be achieved by grounding the balance through placement on an antistatic mat and neutralisation of the particulate filters prior to weighing using a Polonium neutraliser or a device of similar effect. Alternatively, nullification of static effects may be achieved through equalisation of the static charge. 4.5.3.12.1.3.4.4. | A test filter shall be removed from the chamber no earlier than an hour before the test begins.
4.5.4.2. Vehicle speed toleranceschanged
4.5.4.2.1. | The vehicle speed tolerance at any given time on the test cycles prescribed in point 4.5.4.1. is defined by upper and lower limits. The upper limit is 3,2 km/h higher than the highest point on the trace within one second of the given time. The lower limit is 3,2 km/h lower than the lowest point on the trace within one second of the given time. Vehicle speed variations greater than the tolerances (such as may occur during gear changes) are acceptable provided they occur for less than two seconds on any occasion. Vehicle speeds lower than those prescribed are acceptable provided the vehicle is operated at maximum available power during such occurrences. Figure 1-4 shows the range of acceptable vehicle speed tolerances for typical points. Figure 1-4 Drivers trace, allowable range 4.5.4.2.2. | If the acceleration capability of the vehicle is not sufficient to carry out the acceleration phases or if the maximum design speed of the vehicle is lower than the prescribed cruising speed within the prescribed limits of tolerances, the vehicle shall be driven with the throttle fully open until the set speed is reached or at the maximum design speed achievable with fully opened throttle during the time that the set speed exceeds the maximum design speed. In both cases, point 4.5.4.2.1. is not applicable. The test cycle shall be carried on normally when the set speed is again lower than the maximum design speed of the vehicle. 4.5.4.2.3. | If the period of deceleration is shorter than that prescribed for the corresponding phase, the set speed shall be restored by a constant vehicle speed or idling period merging into succeeding constant speed or idling operation. In such cases, point 4.5.4.2.1. is not applicable. 4.5.4.2.4. | Apart from these exceptions, the deviations of the roller speed from the set speed of the cycles shall meet the requirements described in point 4.5.4.2.1. If not, the test results shall not be used for further analysis and the run must be repeated.
4.5.5.2.1.1. Step 1 — Calculation of shift speedschanged
Upshift speeds (v1→2 and vi→i + 1) in km/h during acceleration phases shall be calculated using the following formulae: Equation 2-3: Equation 2-4: where: ‘i’ is the gear number (≥ 2) ‘ng’ is the total number of forward gears ‘Pn’ is the rated power in kW ‘mk’ is the reference mass in kg ‘nidle’ is the idling speed in min–1 ‘s’ is the rated engine speed in min–1 ‘ndvi’ is the ratio between engine speed in min–1 and vehicle speed in km/h in gear ‘i’ 4.5.5.2.1.2. | Downshift speeds (vi→i – 1) in km/h during cruise or deceleration phases in gears 4 (4th gear) to ng shall be calculated using the following formula: Equation 2-5: , i = 4 to ngwhere: i is the gear number (≥ 4) ng is the total number of forward gears Pn is the rated power in kW mk is the reference mass in kg nidle is the idling speed in min–1 s is the rated engine speed in min–1 ndvi-2 is the ratio between engine speed in min–1 and vehicle speed in km/h in gear i – 2 The downshift speed from gear 3 to gear 2 (v3→2) shall be calculated using the following equation: Equation 2-6: where: Pn is the rated power in kW mk is the reference mass in kg nidle is the idling speed in min–1 s is the rated engine speed in min–1 ndv1 is the ratio between engine speed in min–1 and vehicle speed in km/h in gear 1 The downshift speed from gear 2 to gear 1 (v2→1) shall be calculated using the following equation: Equation 2-7: where: ndv2 is the ratio between engine speed in min–1 and vehicle speed in km/h in gear 2 Since the cruise phases are defined by the phase indicator, slight speed increases could occur and it may be appropriate to apply an upshift. The upshift speeds (v1→2, v2→3 and vi→i + 1) in km/h during cruise phases shall be calculated using the following equations: Equation 2-7a: Equation 2-8: Equation 2-9: , i = 3 to ng 4.5.5.2.1.3. | Step 2 — Gear choice for each cycle sampleIn order to avoid different interpretations of acceleration, deceleration, cruise and stop phases, corresponding indicators are added to the vehicle speed pattern as integral parts of the cycles (see tables in Appendix 6). The appropriate gear for each sample shall then be calculated according to the vehicle speed ranges resulting from the shift speed equations of point 4.5.5.2.1.1. and the phase indicators for the cycle parts appropriate for the test vehicle, as follows: Gear choice for stop phases: For the last five seconds of a stop phase, the gear lever shall be set to gear 1 and the clutch shall be disengaged. For the previous part of a stop phase, the gear lever shall be set to neutral or the clutch shall be disengaged. Gear choice for acceleration phases: gear 1, if v ≤ v1→2 gear 2, if v1→2 < v ≤ v2→3 gear 3, if v2→3 < v ≤ v3→4 gear 4, if v3→4 < v ≤ v4→5 gear 5, if v4→5 < v ≤ v5→6 gear 6, if v > v5→6 Gear choice for deceleration or cruise phases: gear 1, if v < v2→1 gear 2, if v < v3→2 gear 3, if v3→2 ≤ v < v4→3 gear 4, if v4→3 ≤ v < v5→4 gear 5, if v5→4 ≤ v < v6→5 gear 6, if v ≥ v4→5 The clutch shall be disengaged, if: (a) the vehicle speed drops below 10 km/h, or (b) the engine speed drops below ; (c) there is a risk of engine stalling during cold-start phase.
Equation 2-4:added
where: 4.5.5.2.1.2. | Downshift speeds (vi→i – 1) in km/h during cruise or deceleration phases in gears 4 (4th gear) to ng shall be calculated using the following formula: Equation 2-5: , i = 4 to ngwhere: i is the gear number (≥ 4) ng is the total number of forward gears Pn is the rated power in kW Mref is the reference mass in kg nidle is the idling speed in min–1 s is the rated engine speed in min–1 ndvi – 2 is the ratio between engine speed in min–1 and vehicle speed in km/h in geari – 2 The downshift speed from gear 3 to gear 2 (v3→2) shall be calculated using the following equation: Equation 2-6: where: Pn is the rated power in kW Mref is the reference mass in kg nidle is the idling speed in min–1 s is the rated engine speed in min–1 ndv1 is the ratio between engine speed in min–1 and vehicle speed in km/h in gear 1 The downshift speed from gear 2 to gear 1 (v2→1) shall be calculated using the following equation: Equation 2-7: where: ndv2 is the ratio between engine speed in min–1 and vehicle speed in km/h in gear 2 Since the cruise phases are defined by the phase indicator, slight speed increases could occur and it may be appropriate to apply an upshift. The upshift speeds (v1→2, v2→3 and vi→i + 1) in km/h during cruise phases shall be calculated using the following equations: Equation 2-7a: Equation 2-8: Equation 2-9: , i = 3 to ng 4.5.5.2.1.3. | Step 2 — Gear choice for each …
4.5.6.1.2. Inertia mass settingchanged
4.5.6.1.2.1. | The equivalent inertia mass mi for the chassis dynamometer shall be the flywheel equivalent inertia mass, mfi, closest to the sum of the mass in running order of the vehicle and the mass of the driver (75 kg). Alternatively, the equivalent inertia mass mi can be derived from Appendix 5. 4.5.6.1.2.2. | If the reference mass mref cannot be equalised to the flywheel equivalent inertia mass mi, to make the target running resistance force F* equal to the running resistance force FE (which is to be set to the chassis dynamometer), the corrected coast-down time ΔTE may be adjusted in accordance with the total mass ratio of the target coast-down time ΔTroad in the following sequence: Equation 2-10: Equation 2-11: Equation 2-12: Equation 2-13: with where: mr1 may be measured or calculated, in kilograms, as appropriate. ►M2 As an alternative, mr1 may be estimated as f 4 percent of m. ◄
5.1.1. Type I test (verifying the average emissio…changed
5.1.1.1. | The test shall be carried out by the method described in point 5.2. The gases shall be collected and analysed by the prescribed methods. 5.1.1.2. | Number of tests 5.1.1.2.1. The number of tests shall be determined as shown in figure 1-5. Ri1 to Ri3 describe the final measurement results for the first (No 1) test to the third (No 3) test and the gaseous pollutant, carbon dioxide emission, fuel / energy consumption or electric range as laid down in Annex VII. ‘Lx’ ‘Lx ’ represents the limit values L1 to L5 as defined in Parts A, B and C of Annex VI to Regulation (EU) No 168/2013. 5.1.1.2.2. In each test, the masses of the carbon monoxide, hydrocarbons, nitrogen oxides, carbon dioxide and the fuel consumed during the test shall be determined. The mass of particulate matter shall be determined only for those (sub-)categories referred to in Parts A and B of Annex VI to Regulation (EU) No 168/2013 (see explanatory notes 8 and 9 at the end of Annex VIII to that Regulation). Figure 1-5 Flowchart for the number of type I tests 5.1.1.2.1. | The number of tests shall be determined as shown in figure 1-5. Ri1 to Ri3 describe the final measurement results for the first (No 1) test to the third (No 3) test and the gaseous pollutant, carbon dioxide emission, fuel / energy consumption or electric range as laid down in Annex VII. ‘Lx’ ‘Lx ’ represents the limit values L1 to L5 as defined in Parts A, B and C of Annex VI to Regulation (EU) No 168/2013. 5.1.1.2.2. | In each test, the masses of the carbon monoxide, hydrocarbons, nitrogen oxides, carbon dioxide and the fuel consumed during the test shall be determined. The mass of particulate matter shall be determined only for those (sub-)categories referred to in Parts A and B of Annex VI to Regulation (EU) No 168/2013 (see explanatory notes 8 and 9 at the end of Annex VIII to that Regulation).
5.2.2.2.3. Total friction losschanged
The total friction loss Ff(v0) Ff(v0 ) at the reference speed v0 is calculated using the following equation: Equation 2-18:
5.2.2.2.5.4. Chassis dynamometer with f* 0, f* …changed
In the case of a chassis dynamometer with a coefficient digital setter, where a central processor unit is incorporated in the system, the target running resistance force is automatically set on the chassis dynamometer. In this case, the coefficients f* 0 and f* 2 are directly input digitally; the coast-down is performed and the coast-down time Δti is measured. Fpau is automatically calculated and set at vehicle speed intervals of 0,06 km/h, in the following sequence: Equation 2-25: Equation 2-26: Equation 2-27:
5.2.2.2.6.2. Calculation of setting errorchanged
The setting error ε is calculated by the following equation: Equation 2-29: The chassis dynamometer shall be readjusted if the setting error does not satisfy the following criteria: ε ≤ 2 percent for v0≥ 50 km/h ε ≤ 3 percent for 30 km/h ≤ v0< 50 km/h ε ≤ 10 percent for v0< 30 km/h The procedure in points 5.2.2.2.6.1. to 5.2.2.2.6.2. shall be repeated until the setting error satisfies the criteria. The chassis dynamometer setting and the observed errors shall be recorded. Specimen record forms are provided in the template of the test report laid down in accordance with Article 32(1) of Regulation (EU) No 168/2013.
5.2.3. Calibration of analyserschanged
5.2.3.1. | The quantity of gas at the indicated pressure compatible with the correct functioning of the equipment shall be injected into the analyser with the aid of the flow metre and the pressure-reducing valve mounted on each gas cylinder. The apparatus shall be adjusted to indicate as a stabilised value the value inserted on the standard gas cylinder. Starting from the setting obtained with the gas cylinder of greatest capacity, a curve shall be drawn of the deviations of the apparatus according to the content of the various standard cylinders used. The flame ionisation analyser shall be recalibrated periodically, at intervals of not more than one month, using air/propane or air/hexane mixtures with nominal hydrocarbon concentrations equal to 50 percent and 90 percent of full scale. 5.2.3.2. | Non-dispersive infrared absorption analysers shall be checked at the same intervals using nitrogen/ CO and nitrogen/ CO2 mixtures in nominal concentrations equal to 10, 40, 60, 85 and 90 percent of full scale. 5.2.3.3. | To calibrate the NOX chemiluminescence analyser, nitrogen/nitrogen oxide (NO) mixtures with nominal concentrations equal to 50 percent and 90 percent of full scale shall be used. The calibration of all three types of analysers shall be checked before each series of tests, using mixtures of the gases, which are measured in a concentration equal to 80 percent of full scale. A dilution device can be applied for diluting a 100 percent calibration gas to required concentration. 5.2.3.4. | Heated flame ionisation detector (FID) (analyser) hydrocarbon response check procedure5.2.3.4.1. Detector response optimisation The FID shall be adjusted according to the manufacturer’s specifications. To optimise the response, propane in air shall be used on the most common operating range. 5.2.3.4.2. Calibration of the hydrocarbon analyser The analyser shall be calibrated using propane in air and purified synthetic air (see point 5.2.3.6.). A calibration curve shall be established as described in point 5.2.3.1 to 5.2.3.3. 5.2.3.4.3. Response factors of different hydrocarbons and recommended limits The response factor (Rf) for a particular hydrocarbon species is the ratio of the FID C1 reading to the gas cylinder concentration, expressed as ppm C1. The concentration of the test gas shall be at a level to give a response of approximately 80 percent of full-scale deflection for the operating range. The concentration shall be known to an accuracy of 2 percent in reference to a gravimetric standard expressed in volume. In addition, the gas cylinder shall be pre-conditioned for 24 hours at a temperature of between 293,2 K and 303,2 K (20 °C and 30 °C). Response factors shall be determined when introducing an analyser into service and thereafter at major service intervals. The test gases to be used and the recommended response factors are: Methane and purified air: 1,00 < Rf < 1,15 or 1,00 < Rf < 1,05 for NG/biomethane-fuelled vehicles Propylene and purified air: 0,90 < Rf < 1,00 Toluene and purified air: 0,90 < Rf < 1,00 These are relative to a response factor (Rf) of 1,00 for propane and purified air. 5.2.3.5. | Calibration and verification procedures of the particulate mass emissions measurement equipment5.2.3.5.1. Flow meter calibration The technical service shall check that a calibration certificate has been issued for the flow meter demonstrating compliance with a traceable standard within a 12-month period prior to the test, or since any repair or change which could influence calibration. 5.2.3.5.2. Microbalance calibration The technical service shall check that a calibration certificate has been issued for the microbalance demonstrating compliance with a traceable standard within a 12-month period prior to the test. 5.2.3.5.3. Reference filter weighing To determine the specific reference filter weights, at least two unused reference filters shall be weighed within eight hours of, but preferably at the same time as, the sample filter weighing. Reference filters shall be of the same size and material as the sample filter. If the specific weight of any reference filter changes by more than ± 5 μg between sample filter weighings, the sample filter and reference filters shall be reconditioned in the weighing room and then reweighed. This shall be based on a comparison of the specific weight of the reference filter and the rolling average of that filter’s specific weights. The rolling average shall be calculated from the specific weights collected in the period since the reference filters were placed in the weighing room. The averaging period shall be between one day and 30 days. Multiple reconditioning and reweighings of the sample and reference filters are permitted up to 80 hours after the measurement of gases from the emissions test. If, within this period, more than half the reference filters meet the ± 5 μg criterion, the sample filter weighing can be considered valid. If, at the end of this period, two reference filters are used and one filter fails to meet the ± 5 μg criterion, the sample filter weighing may be considered valid provided that the sum of the absolute differences between specific and rolling averages from the two reference filters is no more than 10 μg. If fewer than half of the reference filters meet the ± 5 μg criterion, the sample filter shall be discarded and the emissions test repeated. All reference filters shall be discarded and replaced within 48 hours. In all other cases, reference filters shall be replaced at least every 30 days and in such a manner that no sample filter is weighed without comparison with a reference filter that has been in the weighing room for at least one day. If the weighing room stability criteria outlined in point 4.5.3.12.1.3.4. are not met but the reference filter weighings meet the criteria listed in point 5.2.3.5.3, the vehicle manufacturer has the option of accepting the sample filter weights or voiding the tests, fixing the weighing room control system and re-running the test. Figure 1-6 Particulate sampling probe configuration 5.2.3.6. | Reference gases5.2.3.6.1. Pure gases The following pure gases shall be available, if necessary, for calibration and operation: Purified nitrogen: (purity: ≤ 1 ppm C1, ≤ 1 ppm CO, ≤ 400 ppm CO2, ≤ 0,1 ppm NO); Purified synthetic air: (purity: ≤ 1 ppm C1, ≤ 1 ppm CO, ≤ 400 ppm CO2, ≤ 0,1 ppm NO); oxygen content between 18 and 21 percent by volume; Purified oxygen: (purity > 99,5 percent vol. O2); Purified hydrogen (and mixture containing helium): (purity ≤ 1 ppm C1, ≤400 ppm CO2); Carbon monoxide: (minimum purity 99,5 percent); Propane: (minimum purity 99,5 percent). 5.2.3.6.2. Calibration and span gases Mixtures of gases with the following chemical compositions shall be available: (a) C3H8 and purified synthetic air (see point 5.2.3.5.1.); (b) CO and purified nitrogen; (c) CO2 and purified nitrogen; (d) NO and purified nitrogen (the amount of NO2 contained in this calibration gas shall not exceed 5 percent of the NO content). The true concentration of a calibration gas shall be within ± 2 percent of the stated figure. 5.2.3.6. | Calibration and verification of the dilution systemThe dilution system shall be calibrated and verified and shall comply with the requirements of Appendix 4.
—deleted
the concentrations of hydrocarbons, carbon monoxide, nitrogen oxides and carbon dioxide in the sample of dilution air contained in bag(s) B;
—deleted
the concentrations of hydrocarbons, carbon monoxide, nitrogen oxides and carbon dioxide in the sample of diluted exhaust gases contained in bag(s) A.
6.1.1.4.1. Total volume of diluted gaschanged
The total volume of diluted gas, expressed in m3/cycle part, adjusted to the reference conditions of 273,2 K (0 °C ) and 101,3 kPa, is calculated by Equation 2-32: where: V0 is the volume of gas displaced by pump P during one revolution, expressed in m3/revolution. This volume is a function of the differences between the intake and output sections of the pump; N is the number of revolutions made by pump P during each part of the test; Pa is the ambient pressure in kPa; Pi is the average under-pressure during the test part in the intake section of pump P, expressed in kPa; TP is the temperature (expressed in K) of the diluted gases during the test part, measured in the intake section of pump P.
6.1.1.4.2. Hydrocarbons (HC)changed
The mass of unburned hydrocarbons emitted by the exhaust of the vehicle during the test shall be calculated using the following formula: Equation 2-33: where: HCm is the mass of hydrocarbons emitted during the test part, in mg/km; S is the distance defined in point 6.1.1.3.; V is the total volume, defined in point 6.1.1.4.1.; dHC is the density of the hydrocarbons at reference temperature and pressure (273,2 K and 101,3 kPa); dHC | = | 0,631 · 103 mg/m3 for petrol (E5) (C1H1,89O0,016); = 932 · 103 mg/m3 for ethanol (E85) (C1H2,74O0,385); = 622 · 103 mg/m3 for diesel (B5) (C1Hl,86O0,005); = 649 · 103 mg/m3 for LPG (C1H2,525); = 714 · 103 mg/m3 for NG/biogas (C1H4); = mg/m3 for H2NG (with A = NG/biomethane quantity within the H2NG mixture in (volume %)). HCc is the concentration of diluted gases, expressed in parts per million (ppm) of carbon equivalent (e.g. the concentration in propane multiplied by three), corrected to take account of the dilution air by the following equation: Equation 2-34: where: HCe is the concentration of hydrocarbons expressed in parts per million (ppm) of carbon equivalent, in the sample of diluted gases collected in bag(s) A; HCd is the concentration of hydrocarbons expressed in parts per million (ppm) of carbon equivalent, in the sample of dilution air collected in bag(s) B; DiF is the coefficient defined in point 6.1.1.4.7. The non-methane hydrocarbon (NMHC) concentration is calculated as follows: Equation 2-35: CNMHC = CTHC – (Rf CH4 · CCH4) where: CNMHC = corrected concentration of NMHC in the diluted exhaust gas, expressed in ppm carbon equivalent; CTHC = concentration of total hydrocarbons (THC) in the diluted exhaust gas, expressed in ppm carbon equivalent and corrected by the amount of THC contained in the dilution air; CCH4 = concentration of methane (CH4) in the diluted exhaust gas, expressed in ppm carbon equivalent and corrected by the amount of CH4 contained in the dilution air; Rf CH4 is the FID response factor to methane as defined in point 5.2.3.4.1.
6.1.1.4.3. Carbon monoxide (CO)changed
The mass of carbon monoxide emitted by the exhaust of the vehicle during the test shall be calculated using the following formula: Equation 2-36: where: COm is the mass of carbon monoxide emitted during the test part, in mg/km; S is the distance defined in point 6.1.1.3.; V is the total volume defined in point 6.1.1.4.1.; dCO is the density of the carbon monoxide, dCO = 1,25 · 106 mg/m3 at reference temperature and pressure (273,2 K and 101,3 kPa); COc is the concentration of diluted gases, expressed in parts per million (ppm) of carbon monoxide, corrected to take account of the dilution air by the following equation: Equation 2-37: where: COe is the concentration of carbon monoxide expressed in parts per million (ppm), in the sample of diluted gases collected in bag(s) A; COd is the concentration of carbon monoxide expressed in parts per million (ppm), in the sample of dilution air collected in bag(s) B; DiF is the coefficient defined in point 6.1.1.4.7.
6.1.1.4.4. Nitrogen oxides (NOx)changed
The mass of nitrogen oxides emitted by the exhaust of the vehicle during the test shall be calculated using the following formula: Equation 2-38: where: NOxm is the mass of nitrogen oxides emitted during the test part, in mg/km; S is the distance defined in point 6.1.1.3.; V is the total volume defined in point 6.1.1.4.1.; is the density of the nitrogen oxides in the exhaust gases, assuming that they will be in the form of nitric oxide, = 2,05 · 106 mg/m3 at reference temperature and pressure (273,2 K and 101,3 kPa); NOxc is the concentration of diluted gases, expressed in parts per million (ppm), corrected to take account of the dilution air by the following equation: Equation 2-39: where: NOxe is the concentration of nitrogen oxides expressed in parts per million (ppm) of nitrogen oxides, in the sample of diluted gases collected in bag(s) A; NOxd is the concentration of nitrogen oxides expressed in parts per million (ppm) of nitrogen oxides, in the sample of dilution air collected in bag(s) B; DiF is the coefficient defined in point 6.1.1.4.7. Kh is the humidity correction factor, calculated using the following formula: Equation 2-40: where: H is the absolute humidity in g of water per kg of dry air: Equation 2-41: where: U is the humidity as a percentage; Pd is the saturated pressure of water at the test temperature, in kPa; Pa is the atmospheric pressure in kPa.
6.1.1.4.5. Particulate matter masschanged
Particulate emission Mp (mg/km) is calculated by means of the following equation: Equation 2-42: where exhaust gases are vented outside the tunnel; Equation 2-43: where exhaust gases are returned to the tunnel; where: Vmix | = | volume V of diluted exhaust gases under standard conditions; Vep | = | volume of exhaust gas flowing through particulate filter under standard conditions; Pe | = | particulate mass collected by filter(s) in mg; S | = | is the distance defined in point 6.1.1.3.; Mp | = | particulate emission in mg/km. Where correction for the particulate background level from the dilution system has been used, this shall be determined in accordance with point 5.2.1.5. In this case, the particulate mass (mg/km) shall be calculated as follows: Equation 2-44: where exhaust gases are vented outside the tunnel; Equation 2-45: where exhaust gases are returned to the tunnel; where: Vap = volume of tunnel air flowing through the background particulate filter under standard conditions; Pa = particulate mass collected by background filter; DiF is the coefficient defined in point 6.1.1.4.7. Where application of a background correction results in a negative particulate mass (in mg/km), the result shall be considered to be zero mg/km particulate mass.
6.1.1.4.6. Carbon dioxide (CO2)changed
The mass of carbon dioxide emitted by the exhaust of the vehicle during the test shall be calculated using the following formula: Equation 2-46: where: CO2m is the mass of carbon dioxide emitted during the test part, in g/km; S is the distance defined in point 6.1.1.3.; V is the total volume defined in point 6.1.1.4.1.; is the density of the carbon monoxide, = 1,964 · 103 g/m3 at reference temperature and pressure (273,2 K and 101,3 kPa); CO2c is the concentration of diluted gases, expressed as a percentage of carbon dioxide equivalent, corrected to take account of the dilution air by the following equation: Equation 2-47: where: CO2e is the concentration of carbon dioxide expressed as a percentage of the sample of diluted gases collected in bag(s) A; CO2d is the concentration of carbon dioxide expressed as a percentage of the sample of dilution air collected in bag(s) B; DiF is the coefficient defined in point 6.1.1.4.7.
6.1.1.4.7. Dilution factor (DiF)changed
The dilution factor is calculated as follows: For each reference fuel, except hydrogen: Equation 2-48: For a fuel of composition CxHyOz, the general formula is: Equation 2-49: For H2NG, the formula is: Equation 2-50: For hydrogen, the dilution factor is calculated as follows: Equation 2-51: For the reference fuels contained in Appendix x, the values of ‘X’ are as follows: Table 1-8 Factor ‘X’ in formulae to calculate DiF Fuel | X Petrol (E5) | 13,4 Diesel (B5) | 13,5 LPG | 11,9 NG/biomethane | 9,5 Ethanol (E85) | 12,5 Hydrogen | 35,03 In these equations: = concentration of CO2 in the diluted exhaust gas contained in the sampling bag, expressed in percent by volume, CHC | = | concentration of HC in the diluted exhaust gas contained in the sampling bag, expressed in ppm carbon equivalent, CCO | = | concentration of CO in the diluted exhaust gas contained in the sampling bag, expressed in ppm, = concentration of H2O in the diluted exhaust gas contained in the sampling bag, expressed in percent by volume, = concentration of H2O in the air used for dilution, expressed in percent by volume, = concentration of hydrogen in the diluted exhaust gas contained in the sampling bag, expressed in ppm, A | = | quantity of NG/biomethane in the H2NG mixture, expressed in percent by volume.
6.1.1.5. Weighting of type I test resultschanged
6.1.1.5.1. | With repeated measurements (see point 5.1.1.2.), the pollutant (mg/km), and CO2 emission results obtained by the calculation method described in point 6.1.1. and fuel / energy consumption and electric range determined according to Annex VII are averaged for each cycle part. 6.1.1.5.1.1 ►M1 Weighting of results from ECE R40 and ECE R47 test cycles ◄ The (average) result of the cold phase of UNECE regulation No 40 and of regulation No 47 test cycle is called R1; the (average) result of the warm phase of UNECE regulation No 40 and of regulation No 47 test cycle is called R2. Using these pollutant (mg/km) and CO2 (g/km) emission results, the final result R, depending on the vehicle class as defined in point 6.3., shall be calculated using the following equations: Equation 2-52: where: w1 = weighting factor cold phase w2 = weighting factor warm phase 6.1.1.5.1.2 Weighting of WMTC results The (average) result of Part 1 or Part 1 reduced vehicle speed is called R1, the (average) result of Part 2 or Part 2 reduced vehicle speed is called R2 and the (average) result of Part 3 or part 3 reduced vehicle speed is called R3. Using these emission (mg/km) and fuel consumption (litres/100 km) results, the final result R, depending on the vehicle category as defined in point 6.1.1.6.2., shall be calculated using the following equations: Equation 2-53: where: w1 = weighting factor cold phase w2 = weighting factor warm phase Equation 2-54: where: wn = weighting factor phase n (n=1, 2 or 3) w1 | = | weighting factor cold phase w2 | = | weighting factor warm phase w1 | = | weighting factor cold phase w2 | = | weighting factor warm phase wn | = | weighting factor phase n (n=1, 2 or 3) 6.1.1.6.2. | For each pollutant emission constituent, the carbon dioxide emission weightings shown in Tables 1-9 (Euro 4) and 1-10 (Euro 5) shall be used. 6.1.1.6.2.1. Table 1-9 Type I test cycles (also applicable for test types VII and VIII) for Euro 4 compliant L-category vehicles, applicable weighting equations and weighting factors Vehicle category Vehicle category name Test cycle Equation number Weighting factors L1e-A Powered cycle ECE R47 2-52 w1 = 0,30 w2 = 0,70 L1e-B Two-wheel moped L2e Three-wheel moped L6e-A Light on-road quad L6e-B Light quadri-mobile L3e L4e Two-wheel motorcycle with and without side-car vmax < 130 km/h WMTC, stage 2 2-53 w1 = 0,30 w2 = 0,70 L5e-A Tricycle vmax < 130 km/h L7e-A Heavy on-road quad vmax < 130 km/h L3e L4e Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h WMTC, stage 2 2-54 w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A Tricycle vmax ≥ 130 km/h L7e-A Heavy on-road quad vmax ≥ 130 km/h L5e-B Commercial tricycle ECE R40 2-52 w1 = 0,30 w2 = 0,70 L7e-B All-terrain vehicles L7e-C Heavy quadri-mobile 6.1.1.6.2.2. Table 1-10 Type I test cycles (also applicable for test types VII and VIII) for Euro 5 compliant L-category vehicles, applicable weighting equations and weighting factors Vehicle category Vehicle category name Test cycle Equation # Weighting factors L1e-A Powered cycle WMTC stage 3 2-53 w1 = 0,50 w2 = 0,50 L1e-B Two-wheel moped L2e Three-wheel moped L6e-A Light on-road quad L6e-B Light quadri-mobile L3e L4e Two-wheel motorcycle with and without side-car vmax < 130 km/h 2-53 ►M2 w1 = 0,50 0,30 w2 = 0,50 0,70 ◄ L5e-A Tricycle vmax < 130 km/h L7e-A Heavy on-road quad vmax < 130 km/h L3e L4e Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h 2-54 w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A Tricycle vmax ≥ 130 km/h L7e-A Heavy on-road quad vmax ≥ 130 km/h L5e-B Commercial tricycle 2-53 w1 = 0,30 w2 = 0,70 L7e-B All-terrain vehicles L7e-C Heavy quadri-mobile 6.1.1.6.2.1. | Table 1-9 Type I test cycles (also applicable for test types VII and VIII) for Euro 4 compliant L-category vehicles, applicable weighting equations and weighting factors Vehicle category Vehicle category name Test cycle Equation number Weighting factors L1e-A Powered cycle ECE R47 2-52 w1 = 0,30 w2 = 0,70 L1e-B Two-wheel moped L2e Three-wheel moped L6e-A Light on-road quad L6e-B Light quadri-mobile L3e L4e Two-wheel motorcycle with and without side-car vmax < 130 km/h WMTC, stage 2 2-53 w1 = 0,30 w2 = 0,70 L5e-A Tricycle vmax < 130 km/h L7e-A Heavy on-road quad vmax < 130 km/h L3e L4e Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h WMTC, stage 2 2-54 w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A Tricycle vmax ≥ 130 km/h L7e-A Heavy on-road quad vmax ≥ 130 km/h L5e-B Commercial tricycle ECE R40 2-52 w1 = 0,30 w2 = 0,70 L7e-B All-terrain vehicles L7e-C Heavy quadri-mobile Vehicle category | Vehicle category name | Test cycle | Equation number | Weighting factors L1e-A | Powered cycle | ECE R47 | 2-52 | w1 = 0,30 w2 = 0,70 L1e-B | Two-wheel moped L2e | Three-wheel moped L6e-A | Light on-road quad L6e-B | Light quadri-mobile L3e L4e | Two-wheel motorcycle with and without side-car vmax < 130 km/h | WMTC, stage 2 | 2-53 | w1 = 0,30 w2 = 0,70 L5e-A | Tricycle vmax < 130 km/h L7e-A | Heavy on-road quad vmax < 130 km/h L3e L4e | Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h | WMTC, stage 2 | 2-54 | w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A | Tricycle vmax ≥ 130 km/h L7e-A | Heavy on-road quad vmax ≥ 130 km/h L5e-B | Commercial tricycle | ECE R40 | 2-52 | w1 = 0,30 w2 = 0,70 L7e-B | All-terrain vehicles L7e-C | Heavy quadri-mobile 6.1.1.6.2.2. | Table 1-10 Type I test cycles (also applicable for test types VII and VIII) for Euro 5 compliant L-category vehicles, applicable weighting equations and weighting factors Vehicle category Vehicle category name Test cycle Equation # Weighting factors L1e-A Powered cycle WMTC stage 3 2-53 w1 = 0,50 w2 = 0,50 L1e-B Two-wheel moped L2e Three-wheel moped L6e-A Light on-road quad L6e-B Light quadri-mobile L3e L4e Two-wheel motorcycle with and without side-car vmax < 130 km/h 2-53 ►M2 w1 = 0,50 0,30 w2 = 0,50 0,70 ◄ L5e-A Tricycle vmax < 130 km/h L7e-A Heavy on-road quad vmax < 130 km/h L3e L4e Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h 2-54 w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A Tricycle vmax ≥ 130 km/h L7e-A Heavy on-road quad vmax ≥ 130 km/h L5e-B Commercial tricycle 2-53 w1 = 0,30 w2 = 0,70 L7e-B All-terrain vehicles L7e-C Heavy quadri-mobile Vehicle category | Vehicle category name | Test cycle | Equation # | Weighting factors L1e-A | Powered cycle | WMTC stage 3 | 2-53 | w1 = 0,50 w2 = 0,50 L1e-B | Two-wheel moped L2e | Three-wheel moped L6e-A | Light on-road quad L6e-B | Light quadri-mobile L3e L4e | Two-wheel motorcycle with and without side-car vmax < 130 km/h | 2-53 | ►M2 w1 = 0,50 0,30 w2 = 0,50 0,70 ◄ L5e-A | Tricycle vmax < 130 km/h L7e-A | Heavy on-road quad vmax < 130 km/h L3e L4e | Two-wheel motorcycle with and without side-car vmax ≥ 130 km/h | 2-54 | w1 = 0,25 w2 = 0,50 w3 = 0,25 L5e-A | Tricycle vmax ≥ 130 km/h L7e-A | Heavy on-road quad vmax ≥ 130 km/h L5e-B | Commercial tricycle | 2-53 | w1 = 0,30 w2 = 0,70 L7e-B | All-terrain vehicles L7e-C | Heavy quadri-mobile
Symbols used in Annex IIdeleted
Symbol | Definition | Unit a | Coefficient of polygonal function | — aT | Rolling resistance force of front wheel | N b | Coefficient of polygonal function | — bT | Coefficient of aerodynamic function c | Coefficient of polygonal function | — CCO | Concentration of carbon monoxide | percent vol. CCOcorr | Corrected concentration of carbon monoxide | percent vol. CO2c | Carbon dioxide concentration of diluted gas, corrected to take account of diluent air | percent CO2d | Carbon dioxide concentration in the sample of diluent air collected in bag B | percent CO2e | Carbon dioxide concentration in the sample of diluent air collected in bag A | percent CO2m | Mass of carbon dioxide emitted during the test part | g/km COc | Carbon monoxide concentration of diluted gas, corrected to take account of diluent air | ppm COd | Carbon monoxide concentration in the sample of diluent air, collected in bag B | ppm COe | Carbon monoxide concentration in the sample of diluent air, collected in bag A | ppm COm | Mass of carbon monoxide emitted during the test part | mg/km d0 | Standard ambient relative air density | — dCO | Density of carbon monoxide | mg/m3 dCO2 | Density of carbon dioxide | mg/m3 ▼M1 DiF | Dilution factor | — ▼B dHC | Density of hydrocarbon | mg/m3 S / d | Distance driven in a cycle part | km dNOX | Density of nitrogen oxide | mg/m3 dT | Relative air density under test condition | — Δt | Coast-down time | s Δtai | Coast-down time measured in the first road test | s Δtbi | Co…
1. Specifications of reference fuels for testin…deleted
1.1. The following tables list the technical data on liquid reference fuels to be used for environmental performance testing. ►M1 The fuel specifications in this Appendix are consistent with the reference fuel specifications in Annex 10 to UNECE regulation No 83 Revision 4 ( 5 ). ◄ Type: Petrol (E5) Parameter | Unit | Limits (1) | Test method Minimum | Maximum Research octane number, RON | 95,0 | — | EN 25164 / prEN ISO 5164 Motor octane number, MON | 85,0 | — | EN 25163 / prEN ISO 5163 Density at 15 °C | kg/m3 | 743 | 756 | EN ISO 3675 / EN ISO 12185 Vapour pressure | kPa | 56,0 | 60,0 | EN ISO 13016-1 (DVPE) Water content | % v/v | 0,015 | ASTM E 1064 Distillation: — Evaporated at 70 °C | % v/v | 24,0 | 44,0 | EN ISO 3405 — Evaporated at 100 °C | % v/v | 48,0 | 60,0 | EN ISO 3405 — Evaporated at 150 °C | % v/v | 82,0 | 90,0 | EN ISO 3405 — Final boiling point | °C | 190 | 210 | EN ISO 3405 Residue | % v/v | — | 2,0 | EN ISO 3405 Hydrocarbon analysis: — Olefins | % v/v | 3,0 | 13,0 | ASTM D 1319 — Aromatics | % v/v | 29,0 | 35,0 | ASTM D 1319 — Benzene | % v/v | — | 1,0 | EN 12177 — Saturates | % v/v | Report | ASTM 1319 Carbon/hydrogen ratio | Report Carbon/oxygen ratio | Report Induction period (2) | minutes | 480 | — | EN ISO 7536 Oxygen content (3) | % m/m | Report | EN 1601 Existent gum | mg/ml | — | 0,04 | EN ISO 6246 Sulphur content (4) | mg/kg | — | 10 | EN ISO 20846 / EN ISO 20884 Copper corrosion | — | Class 1 | EN ISO 2160 Lead content | mg/l | — | 5 | E…
1.1. General requirementsdeleted
1.1.1. The dynamometer shall be capable of simulating road load within one of the following classifications:
(a)deleted
dynamometer with fixed load curve, i.e. a dynamometer whose physical characteristics provide a fixed load curve shape;
(b)deleted
dynamometer with adjustable load curve, i.e. a dynamometer with at least two road load parameters that can be adjusted to shape the load curve. 1.1.2. Dynamometers with electric inertia simulation shall be demonstrated to be equivalent to mechanical inertia systems. The means by which equivalence is established are described in point 4. 1.1.3. Where the total resistance to progress on the road cannot be reproduced on the chassis dynamometer between speeds of 10 km/h and 120 km/h, it is recommended that a chassis dynamometer with the characteristics defined in point 1.2. should be used. 1.1.3.1. The load absorbed by the brake and the chassis dynamometer (internal frictional effects) between the speeds of 0 and 120 km/h is as follows: Equation Ap3-1: where: F | = | total load absorbed by the chassis dynamometer (N); a | = | value equivalent to rolling resistance (N); b | = | value equivalent to coefficient of air resistance (N/(km/h)2); v | = | vehicle speed (km/h); F80 | = | load at 80 km/h (N). Alternatively for vehicles that cannot attain 80 km/h the load at the reference vehicle speeds vj in table Ap8-1 in Appendix 8 shall be determined.
1.2. Specific requirementsdeleted
1.2.1. The setting of the dynamometer shall not be affected by the lapse of time. It shall not produce any vibrations perceptible to the vehicle and likely to impair the vehicle’s normal operations. 1.2.2. The chassis dynamometer may have one roller or two rollers in the cases of three-wheel vehicles with two front wheels and quadricycles. In such cases, the front roller shall drive, directly or indirectly, the inertial masses and the power-absorption device. 1.2.3. It shall be possible to measure and read the indicated load to an accuracy of ± 5 percent. 1.2.4. In the case of a dynamometer with a fixed load curve, the accuracy of the load setting at 80 km/h or of the load setting at the reference vehicle speeds (30 km/h, respectively 15 km/h) referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h, shall be ± 5 percent. In the case of a dynamometer with adjustable load curve, the accuracy of matching dynamometer load to road load shall be ± 5 percent for vehicle speeds > 20 km/h and ± 10 percent for vehicle speeds ≤ 20 km/h. Below this vehicle speed, dynamometer absorption shall be positive. 1.2.5. The total inertia of the rotating parts (including the simulated inertia where applicable) shall be known and shall be within ± 10 kg of the inertia class for the test. 1.2.6. The speed of the vehicle shall be measured by the speed of rotation of the roller (the front roller in the case of a two-roller dynamometer). It shall be measured with an accuracy of ± 1 km/h …
Symbols used in Annex IIadded
Symbol | Definition | Unit a | Coefficient of polygonal function | — aT | Rolling resistance force of front wheel | N b | Coefficient of polygonal function | — bT | Coefficient of aerodynamic function c | Coefficient of polygonal function | — CCO | Concentration of carbon monoxide | percent vol. CCOcorr | Corrected concentration of carbon monoxide | percent vol. CO2c | Carbon dioxide concentration of diluted gas, corrected to take account of diluent air | percent CO2d | Carbon dioxide concentration in the sample of diluent air collected in bag B | percent CO2e | Carbon dioxide concentration in the sample of diluent air collected in bag A | percent CO2m | Mass of carbon dioxide emitted during the test part | g/km COc | Carbon monoxide concentration of diluted gas, corrected to take account of diluent air | ppm COd | Carbon monoxide concentration in the sample of diluent air, collected in bag B | ppm COe | Carbon monoxide concentration in the sample of diluent air, collected in bag A | ppm COm | Mass of carbon monoxide emitted during the test part | mg/km d0 | Standard ambient relative air density | — dCO | Density of carbon monoxide | mg/m3 dCO2 | Density of carbon dioxide | mg/m3 ▼M1 DiF | Dilution factor | — ▼B dHC | Density of hydrocarbon | mg/m3 S / d | Distance driven in a cycle part | km dNOX | Density of nitrogen oxide | mg/m3 dT | Relative air density under test condition | — Δt | Coast-down time | s Δtai | Coast-down time measured in the first road test | s Δtbi | Co…
2.1. Introductiondeleted
This section describes the method to be used to determine the load absorbed by a dynamometer brake. The load absorbed comprises the load absorbed by frictional effects and the load absorbed by the power-absorption device. The dynamometer is brought into operation beyond the range of test speeds. The device used for starting up the dynamometer is then disconnected; the rotational speed of the driven roller decreases. The kinetic energy of the rollers is dissipated by the power-absorption unit and by the frictional effects. This method disregards variations in the roller’s internal frictional effects caused by rollers with or without the vehicle. The frictional effects of the rear roller shall be disregarded when the roller is free. 2.2. | Calibration of the load indicator at 80 km/h or of the load indicator referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h. The following procedure shall be used for calibration of the load indicator to 80 km/h or the applicable load indicator referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h, as a function of the load absorbed (see also Figure Ap3-1): 2.2.1. Measure the rotational speed of the roller if this has not already been done. A fifth wheel, a revolution counter or some other method may be used. 2.2.2. Place the vehicle on the dynamometer or devise some other method for starting up the dynamometer. 2.2.3. Use the flywheel or any other s…
3.1. Proceduredeleted
The load-absorption curve of the dynamometer from a reference setting at a speed of 80 km/h or for vehicles that cannot attain 80 km/h at the respective reference vehicle speeds referred to in point 1.1.3.1., shall be verified as follows: 3.1.1. Place the vehicle on the dynamometer or devise some other method for starting up the dynamometer. 3.1.2. Adjust the dynamometer to the absorbed load (F80) at 80 km/h, or for vehicles that cannot attain 80 km/h to the absorbed load Fvj at the respective target vehicle speed vj referred to in point 1.1.3.1. 3.1.3. Note the load absorbed at 120, 100, 80, 60, 40 and 20 km/h or for vehicles that cannot attain 80 km/h absorbed at the target vehicles speeds vj referred to in point 1.1.3.1. 3.1.4. Draw the curve F(v) and verify that it corresponds to the requirements of point 1.1.3.1. 3.1.5. Repeat the procedure set out in points 3.1.1. to 3.1.4. for other values of F80 and for other values of inertia.
1.1.added
The following tables list the technical data on liquid reference fuels to be used for environmental performance testing. ►M1 The fuel specifications in this Appendix are consistent with the reference fuel specifications in Annex 10 to UNECE regulation No 83 Revision 4 ( 5 ). ◄ Type: Petrol (E5) Parameter | Unit | Limits (1) | Test method Minimum | Maximum Research octane number, RON | 95,0 | — | EN 25164 / prEN ISO 5164 Motor octane number, MON | 85,0 | — | EN 25163 / prEN ISO 5163 Density at 15 °C | kg/m3 | 743 | 756 | EN ISO 3675 / EN ISO 12185 Vapour pressure | kPa | 56,0 | 60,0 | EN ISO 13016-1 (DVPE) Water content | % v/v | 0,015 | ASTM E 1064 Distillation: — Evaporated at 70 °C | % v/v | 24,0 | 44,0 | EN ISO 3405 — Evaporated at 100 °C | % v/v | 48,0 | 60,0 | EN ISO 3405 — Evaporated at 150 °C | % v/v | 82,0 | 90,0 | EN ISO 3405 — Final boiling point | °C | 190 | 210 | EN ISO 3405 Residue | % v/v | — | 2,0 | EN ISO 3405 Hydrocarbon analysis: — Olefins | % v/v | 3,0 | 13,0 | ASTM D 1319 — Aromatics | % v/v | 29,0 | 35,0 | ASTM D 1319 — Benzene | % v/v | — | 1,0 | EN 12177 — Saturates | % v/v | Report | ASTM 1319 Carbon/hydrogen ratio | Report Carbon/oxygen ratio | Report Induction period (2) | minutes | 480 | — | EN ISO 7536 Oxygen content (3) | % m/m | Report | EN 1601 Existent gum | mg/ml | — | 0,04 | EN ISO 6246 Sulphur content (4) | mg/kg | — | 10 | EN ISO 20846 / EN ISO 20884 Copper corrosion | — | Class 1 | EN ISO 2160 Lead content | mg/l | — | 5 | EN 237…
4.1. Objectdeleted
The method described in this Appendix makes it possible to check that the simulated total inertia of the dynamometer is carried out satisfactorily in the running phase of the operating cycle. The manufacturer of the chassis dynamometer shall specify a method for verifying the specifications according to point 4.3.
4.2.1. Drawing-up working equationsdeleted
Since the dynamometer is subjected to variations in the rotating speed of the roller(s), the force at the surface of the roller(s) can be expressed by: Equation Ap3-3: where: F is the force at the surface of the roller(s) in N; I is the total inertia of the dynamometer (equivalent inertia of the vehicle); IM is the inertia of the mechanical masses of the dynamometer; γ is the tangential acceleration at roller surface; F1 is the inertia force. Note: An explanation of this formula with reference to dynamometers with mechanically simulated inertia is appended. Thus, total inertia is expressed as follows: Equation Ap3-4: where: Im can be calculated or measured by traditional methods; F1 can be measured on the dynamometer; γ can be calculated from the peripheral speed of the rollers. The total inertia (I) will be determined during an acceleration or deceleration test with values no lower than those obtained on an operating cycle.
4.2.2. Specification for the calculation of total…deleted
The test and calculation methods shall make it possible to determine the total inertia I with a relative error (ΔI/I) of less than ± 2 percent.
1.1.1.added
The dynamometer shall be capable of simulating road load within one of the following classifications:
4.3. Specificationdeleted
4.3.1. | The mass of the simulated total inertia I shall remain the same as the theoretical value of the equivalent inertia (see Appendix 5) within the following limits: 4.3.1.1. ± 5 percent of the theoretical value for each instantaneous value; 4.3.1.2. ± 2 percent of the theoretical value for the average value calculated for each sequence of the cycle. The limit specified in point 4.3.1.1. is brought to ± 50 percent for one second when starting and, for vehicles with manual transmission, for two seconds during gear changes.
(a)added
dynamometer with fixed load curve, i.e. a dynamometer whose physical characteristics provide a fixed load curve shape;
4.4. Verification proceduredeleted
4.4.1. | Verification is carried out during each test throughout the test cycles defined in Appendix 6 of Annex II. 4.4.2. | However, if the requirements laid down in point 4.3. are met, with instantaneous accelerations which are at least three times greater or smaller than the values obtained in the sequences of the theoretical cycle, the verification described in point 4.4.1. will not be necessary.
(b)added
dynamometer with adjustable load curve, i.e. a dynamometer with at least two road load parameters that can be adjusted to shape the load curve.
1.1.2.added
Dynamometers with electric inertia simulation shall be demonstrated to be equivalent to mechanical inertia systems. The means by which equivalence is established are described in point 4.
1.1.3.added
Where the total resistance to progress on the road cannot be reproduced on the chassis dynamometer between speeds of 10 km/h and 120 km/h, it is recommended that a chassis dynamometer with the characteristics defined in point 1.2. should be used.
1.1. System overviewdeleted
A full-flow exhaust dilution system shall be used. This requires that the vehicle exhaust be continuously diluted with ambient air under controlled conditions. The total volume of the mixture of exhaust and dilution air shall be measured and a continuously proportional sample of the volume shall be collected for analysis. The quantities of pollutants are determined from the sample concentrations, corrected for the pollutant content of the ambient air and the totalised flow over the test period. The exhaust dilution system shall consist of a transfer tube, a mixing chamber and dilution tunnel, a dilution air conditioning, a suction device and a flow measurement device. Sampling probes shall be fitted in the dilution tunnel as specified in Appendices 3, 4 and 5. The mixing chamber described in this point shall be a vessel, such as those illustrated in Figures Ap4-1 and Ap4-2, in which vehicle exhaust gases and the dilution air are combined so as to produce a homogeneous mixture at the chamber outlet.
1.1.3.1.added
The load absorbed by the brake and the chassis dynamometer (internal frictional effects) between the speeds of 0 and 120 km/h is as follows: Equation Ap3-1: where: F | = | total load absorbed by the chassis dynamometer (N); a | = | value equivalent to rolling resistance (N); b | = | value equivalent to coefficient of air resistance (N/(km/h)2); v | = | vehicle speed (km/h); F80 | = | load at 80 km/h (N). Alternatively for vehicles that cannot attain 80 km/h the load at the reference vehicle speeds vj in table Ap8-1 in Appendix 8 shall be determined.
1.2. General requirementsdeleted
1.2.1. | The vehicle exhaust gases shall be diluted with a sufficient amount of ambient air to prevent any water condensation in the sampling and measuring system under any conditions which may occur during a test. 1.2.2. | The mixture of air and exhaust gases shall be homogeneous at the point where the sampling probe is located (see point 1.3.3.). The sampling probe shall extract a representative sample of the diluted exhaust gas. 1.2.3. | The system shall enable the total volume of the diluted exhaust gases to be measured. 1.2.4. | The sampling system shall be gas-tight. The design of the variable dilution sampling system and the materials that go to make it up shall be such that they do not affect the pollutant concentration in the diluted exhaust gases. Should any component in the system (heat exchanger, cyclone separator, blower, etc.) change the concentration of any of the pollutants in the diluted exhaust gases and the fault cannot be corrected, sampling for that pollutant shall be carried out upstream from that component. 1.2.5. | All parts of the dilution system that are in contact with raw and diluted exhaust gas shall be designed to minimise deposition or alteration of the particulates or particles. All parts shall be made of electrically conductive materials that do not react with exhaust gas components and shall be electrically grounded to prevent electrostatic effects. 1.2.6. | If the vehicle being tested is equipped with an exhaust pipe comprising several bran…
1.2.1.added
The setting of the dynamometer shall not be affected by the lapse of time. It shall not produce any vibrations perceptible to the vehicle and likely to impair the vehicle’s normal operations.
1.3.1. Connection to vehicle exhaustdeleted
The connecting tube between the vehicle exhaust outlets and the dilution system shall be as short as possible and satisfy the following requirements:
1.2.2.added
The chassis dynamometer may have one roller or two rollers in the cases of three-wheel vehicles with two front wheels and quadricycles. In such cases, the front roller shall drive, directly or indirectly, the inertial masses and the power-absorption device.
(a)deleted
the tube shall be less than 3,6 m long, or less than 6,1 m long if heat insulated. Its internal diameter may not exceed 105 mm;
1.2.3.added
It shall be possible to measure and read the indicated load to an accuracy of ± 5 percent.
(b)deleted
it shall not cause the static pressure at the exhaust outlets on the test vehicle to differ by more than ± 0,75 kPa at 50 km/h, or more than ± 1,25 kPa for the whole duration of the test, from the static pressures recorded when nothing is connected to the vehicle exhaust outlets. The pressure shall be measured in the exhaust outlet or in an extension having the same diameter, as near as possible to the end of the pipe. Sampling systems capable of maintaining the static pressure to within ± 0,25 kPa may be used if a written request from a manufacturer to the technical service substantiates the need for the closer tolerance;
1.2.4.added
In the case of a dynamometer with a fixed load curve, the accuracy of the load setting at 80 km/h or of the load setting at the reference vehicle speeds (30 km/h, respectively 15 km/h) referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h, shall be ± 5 percent. In the case of a dynamometer with adjustable load curve, the accuracy of matching dynamometer load to road load shall be ± 5 percent for vehicle speeds > 20 km/h and ± 10 percent for vehicle speeds ≤ 20 km/h. Below this vehicle speed, dynamometer absorption shall be positive.
(c)deleted
it shall not change the nature of the exhaust gas;
1.2.5.added
The total inertia of the rotating parts (including the simulated inertia where applicable) shall be known and shall be within ± 10 kg of the inertia class for the test.
(d)deleted
any elastomeric connectors employed shall be as thermally stable as possible and have minimum exposure to the exhaust gases.
1.2.6.added
The speed of the vehicle shall be measured by the speed of rotation of the roller (the front roller in the case of a two-roller dynamometer). It shall be measured with an accuracy of ± 1 km/h at vehicle speeds over 10 km/h. The distance actually driven by the vehicle shall be measured by the movement of rotation of the roller (the front roller in the case of a two-roller dynamometer).
1.3.2. Dilution air conditioningdeleted
The dilution air used for the primary dilution of the exhaust in the CVS tunnel shall be passed through a medium capable of reducing particles in the most penetrating particle size of the filter material by ≥ 99,95 percent, or through a filter of at least class H13 of EN 1822:1998. This represents the specification of High Efficiency Particulate Air (HEPA) filters. The dilution air may be charcoal scrubbed before being passed to the HEPA filter. It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal scrubber, if used. At the vehicle manufacturer’s request, the dilution air may be sampled according to good engineering practice to determine the tunnel contribution to background particulate mass levels, which can then be subtracted from the values measured in the diluted exhaust.
1.3.3. Dilution tunneldeleted
Provision shall be made for the vehicle exhaust gases and the dilution air to be mixed. A mixing orifice may be used. In order to minimise the effects on the conditions at the exhaust outlet and to limit the drop in pressure inside the dilution-air conditioning device, if any, the pressure at the mixing point shall not differ by more than ± 0,25 kPa from atmospheric pressure. The homogeneity of the mixture in any cross-section at the location of the sampling probe shall not vary by more than ±2 percent from the average of the values obtained for at least five points located at equal intervals on the diameter of the gas stream. For particulate and particle emissions sampling, a dilution tunnel shall be used which:
2.1. Introductionadded
This section describes the method to be used to determine the load absorbed by a dynamometer brake. The load absorbed comprises the load absorbed by frictional effects and the load absorbed by the power-absorption device. The dynamometer is brought into operation beyond the range of test speeds. The device used for starting up the dynamometer is then disconnected; the rotational speed of the driven roller decreases. The kinetic energy of the rollers is dissipated by the power-absorption unit and by the frictional effects. This method disregards variations in the roller’s internal frictional effects caused by rollers with or without the vehicle. The frictional effects of the rear roller shall be disregarded when the roller is free. 2.2. | Calibration of the load indicator at 80 km/h or of the load indicator referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h. The following procedure shall be used for calibration of the load indicator to 80 km/h or the applicable load indicator referred to in point 1.1.3.1. for vehicles that cannot attain 80 km/h, as a function of the load absorbed (see also Figure Ap3-1): 2.2.1. Measure the rotational speed of the roller if this has not already been done. A fifth wheel, a revolution counter or some other method may be used. 2.2.2. Place the vehicle on the dynamometer or devise some other method for starting up the dynamometer. 2.2.3. Use the flywheel or any other s…
(a)deleted
shall consist of a straight tube of electrically-conductive material, which shall be earthed;
(b)deleted
shall be small enough in diameter to cause turbulent flow (Reynolds number ≥ 4 000 ) and of sufficient length to cause complete mixing of the exhaust and dilution air;
3.1. Procedureadded
The load-absorption curve of the dynamometer from a reference setting at a speed of 80 km/h or for vehicles that cannot attain 80 km/h at the respective reference vehicle speeds referred to in point 1.1.3.1., shall be verified as follows: Place the vehicle on the dynamometer or devise some other method for starting up the dynamometer. Adjust the dynamometer to the absorbed load (F80) at 80 km/h, or for vehicles that cannot attain 80 km/h to the absorbed load Fvj at the respective target vehicle speed vj referred to in point 1.1.3.1. Note the load absorbed at 120, 100, 80, 60, 40 and 20 km/h or for vehicles that cannot attain 80 km/h absorbed at the target vehicles speeds vj referred to in point 1.1.3.1. Draw the curve F(v) and verify that it corresponds to the requirements of point 1.1.3.1. Repeat the procedure set out in points 3.1.1. to 3.1.4. for other values of F80 and for other values of inertia.
(c)deleted
shall be at least 200 mm in diameter;
(d)deleted
may be insulated.
4.1. Objectadded
The method described in this Appendix makes it possible to check that the simulated total inertia of the dynamometer is carried out satisfactorily in the running phase of the operating cycle. The manufacturer of the chassis dynamometer shall specify a method for verifying the specifications according to point 4.3.
1.3.4. Suction devicedeleted
This device may have a range of fixed speeds to ensure sufficient flow to prevent any water condensation. This result is generally obtained if the flow is either:
(a)deleted
twice the maximum flow of exhaust gas produced by accelerations of the driving cycle; or
4.2.1. Drawing-up working equationsadded
Since the dynamometer is subjected to variations in the rotating speed of the roller(s), the force at the surface of the roller(s) can be expressed by: Equation Ap3-3: where: Note: An explanation of this formula with reference to dynamometers with mechanically simulated inertia is appended. Thus, total inertia is expressed as follows: Equation Ap3-4: where: The total inertia (I) will be determined during an acceleration or deceleration test with values no lower than those obtained on an operating cycle.
(b)deleted
sufficient to ensure that the CO2 concentration in the dilute exhaust sample bag is less than 3 percent by volume for petrol and diesel, less than 2,2 percent by volume for LPG and less than 1,5 percent by volume for NG/biomethane.
4.2.2. Specification for the calculation of total…added
The test and calculation methods shall make it possible to determine the total inertia I with a relative error (ΔI/I) of less than ± 2 percent.
1.3.5. Volume measurement in the primary dilution…deleted
The method for measuring total dilute exhaust volume incorporated in the constant volume sampler shall be such that measurement is accurate to ± 2 percent under all operating conditions. If the device cannot compensate for variations in the temperature of the mixture of exhaust gases and dilution air at the measuring point, a heat exchanger shall be used to maintain the temperature to within ± 6 K of the specified operating temperature. If necessary, some form of protection for the volume measuring device may be used, e.g. a cyclone separator, bulk stream filter, etc. A temperature sensor shall be installed immediately before the volume measuring device. This sensor shall have an accuracy and a precision of ± 1 K and a response time of 0,1 s at 62 percent of a given temperature variation (value measured in silicone oil). The difference from atmospheric pressure shall be measured upstream and, if necessary, downstream from the volume measuring device. The pressure measurements shall have a precision and an accuracy of ± 0,4 kPa during the test.
4.3. Specificationadded
4.3.1. | The mass of the simulated total inertia I shall remain the same as the theoretical value of the equivalent inertia (see Appendix 5) within the following limits: 4.3.1.1. ± 5 percent of the theoretical value for each instantaneous value; 4.3.1.2. ± 2 percent of the theoretical value for the average value calculated for each sequence of the cycle. The limit specified in point 4.3.1.1. is brought to ± 50 percent for one second when starting and, for vehicles with manual transmission, for two seconds during gear changes.
1.4. Recommended system descriptionsdeleted
Figure Ap 4-1 and Figure Ap 4-2 are schematic drawings of two types of recommended exhaust dilution systems that meet the requirements of this Annex. Since various configurations can produce accurate results, exact conformity with these figures is not essential. Additional components such as instruments, valves, solenoids and switches may be used to provide additional information and coordinate the functions of the component system.
4.4. Verification procedureadded
4.4.1. | Verification is carried out during each test throughout the test cycles defined in Appendix 6 of Annex II. 4.4.2. | However, if the requirements laid down in point 4.3. are met, with instantaneous accelerations which are at least three times greater or smaller than the values obtained in the sequences of the theoretical cycle, the verification described in point 4.4.1. will not be necessary.
Positive displacement pump dilution systemdeleted
The positive displacement pump (PDP) full-flow dilution system satisfies the requirements of this Annex by metering the flow of gas through the pump at constant temperature and pressure. The total volume is measured by counting the revolutions of the calibrated positive displacement pump. The proportional sample is achieved by sampling with pump, flow meter and flow control valve at a constant flow rate. The collecting equipment consists of: 1.4.1.1. A filter (refer to DAF in Figure Ap 4-1) for the dilution air shall be installed, which can be preheated if necessary. This filter shall consist of the following filters in sequence: an optional activated charcoal filter (inlet side) and a high efficiency particulate air (HEPA) filter (outlet side). It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal filter, if used. The purpose of the charcoal filter is to reduce and stabilise the hydrocarbon concentrations of ambient emissions in the dilution air; 1.4.1.2. A transfer tube (TT) by which vehicle exhaust is admitted into a dilution tunnel (DT) in which the exhaust gas and dilution air are mixed homogeneously; 1.4.1.3. The positive displacement pump (PDP), producing a constant-volume flow of the air/exhaust-gas mixture. The PDP revolutions, together with associated temperature and pressure measurement, are used to determine the flow rate; 1.4.1.4. A heat exchanger (HE) of a capacity sufficient to ensure that through…
1.1. System overviewadded
A full-flow exhaust dilution system shall be used. This requires that the vehicle exhaust be continuously diluted with ambient air under controlled conditions. The total volume of the mixture of exhaust and dilution air shall be measured and a continuously proportional sample of the volume shall be collected for analysis. The quantities of pollutants are determined from the sample concentrations, corrected for the pollutant content of the ambient air and the totalised flow over the test period. The exhaust dilution system shall consist of a transfer tube, a mixing chamber and dilution tunnel, a dilution air conditioning, a suction device and a flow measurement device. Sampling probes shall be fitted in the dilution tunnel as specified in Appendices 3, 4 and 5. The mixing chamber described in this point shall be a vessel, such as those illustrated in Figures Ap4-1 and Ap4-2, in which vehicle exhaust gases and the dilution air are combined so as to produce a homogeneous mixture at the chamber outlet.
1.2. General requirementsadded
1.2.1. | The vehicle exhaust gases shall be diluted with a sufficient amount of ambient air to prevent any water condensation in the sampling and measuring system under any conditions which may occur during a test. 1.2.2. | The mixture of air and exhaust gases shall be homogeneous at the point where the sampling probe is located (see point 1.3.3.). The sampling probe shall extract a representative sample of the diluted exhaust gas. 1.2.3. | The system shall enable the total volume of the diluted exhaust gases to be measured. 1.2.4. | The sampling system shall be gas-tight. The design of the variable dilution sampling system and the materials that go to make it up shall be such that they do not affect the pollutant concentration in the diluted exhaust gases. Should any component in the system (heat exchanger, cyclone separator, blower, etc.) change the concentration of any of the pollutants in the diluted exhaust gases and the fault cannot be corrected, sampling for that pollutant shall be carried out upstream from that component. 1.2.5. | All parts of the dilution system that are in contact with raw and diluted exhaust gas shall be designed to minimise deposition or alteration of the particulates or particles. All parts shall be made of electrically conductive materials that do not react with exhaust gas components and shall be electrically grounded to prevent electrostatic effects. 1.2.6. | If the vehicle being tested is equipped with an exhaust pipe comprising several bran…
Critical-flow venturi dilution systemdeleted
The use of a critical-flow venturi (CFV) for the full-flow dilution system is based on the principles of flow mechanics for critical flow. The variable mixture flow rate of dilution and exhaust gas is maintained at sonic velocity which is directly proportional to the square root of the gas temperature. Flow is continually monitored, computed and integrated throughout the test. The use of an additional critical-flow sampling venturi ensures the proportionality of the gas samples taken from the dilution tunnel. As pressure and temperature are both equal at the two venturi inlets, the volume of the gas flow diverted for sampling is proportional to the total volume of diluted exhaust-gas mixture produced, and thus the requirements of this Annex are met. The collecting equipment consists of: 1.4.2.1. A filter (DAF) for the dilution air which can be preheated if necessary. This filter shall consist of the following filters in sequence: an optional activated charcoal filter (inlet side) and a high efficiency particulate air (HEPA) filter (outlet side). It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal filter, if used. The purpose of the charcoal filter is to reduce and stabilise the hydrocarbon concentrations of ambient emissions in the dilution air; 1.4.2.2. A mixing chamber (MC) in which exhaust gas and air are mixed homogeneously and which may be located close to the vehicle so that the length of the transfer tu…
1.3.1. Connection to vehicle exhaustadded
The connecting tube between the vehicle exhaust outlets and the dilution system shall be as short as possible and satisfy the following requirements:
2.1. General requirementsdeleted
The CVS system shall be calibrated by using an accurate flow-meter and a restricting device. The flow through the system shall be measured at various pressure readings and the control parameters of the system measured and related to the flows. The flow-meter shall be dynamic and suitable for the high flow-rate encountered in CVS testing. The device shall be of certified accuracy traceable to an approved national or international standard. 2.1.1. | Various types of flow-meter may be used, e.g. calibrated venturi, laminar flow-meter, calibrated turbine-meter, provided that they are dynamic measurement systems and can meet the requirements of point 1.3.5. of this Appendix. 2.1.2. | The following points give details of methods of calibrating PDP and CFV units, using a laminar flow-meter which gives the required accuracy, together with a statistical check on the calibration validity.
(a)added
the tube shall be less than 3,6 m long, or less than 6,1 m long if heat insulated. Its internal diameter may not exceed 105 mm;
2.2. Calibration of the positive displacement pum…deleted
2.2.1. | The following calibration procedure outlines the equipment, the test configuration and the various parameters that are measured to establish the flow-rate of the CVS pump. All the parameters relating to the pump are simultaneously measured with the parameters relating to the flow-meter which is connected in series with the pump. The calculated flow rate (given in m3/min at pump inlet, absolute pressure and temperature) can then be plotted against a correlation function that is the value of a specific combination of pump parameters. The linear equation that relates the pump flow and the correlation function is then determined. If a CVS has a multiple speed drive, a calibration shall be performed for each range used. 2.2.2. | This calibration procedure is based on the measurement of the absolute values of the pump and flow-meter parameters that relate to the flow rate at each point. Three conditions shall be maintained to ensure the accuracy and integrity of the calibration curve: 2.2.2.1. The pump pressures shall be measured at tappings on the pump rather than at the external piping on the pump inlet and outlet. Pressure taps that are mounted at the top centre and bottom centre of the pump drive head plate are exposed to the actual pump cavity pressures and therefore reflect the absolute pressure differentials; 2.2.2.2. Temperature stability shall be maintained during the calibration. The laminar flow-meter is sensitive to inlet temperature oscillations which…
(b)added
it shall not cause the static pressure at the exhaust outlets on the test vehicle to differ by more than ± 0,75 kPa at 50 km/h, or more than ± 1,25 kPa for the whole duration of the test, from the static pressures recorded when nothing is connected to the vehicle exhaust outlets. The pressure shall be measured in the exhaust outlet or in an extension having the same diameter, as near as possible to the end of the pipe. Sampling systems capable of maintaining the static pressure to within ± 0,25 kPa may be used if a written request from a manufacturer to the technical service substantiates the need for the closer tolerance;
2.3. Calibration of the critical-flow venturi (CF…deleted
2.3.1. | Calibration of the CFV is based on the flow equation for a critical-flow venturi: Equation Ap 4-4: where: Qs = flow; Kv = calibration coefficient; P = absolute pressure (kPa); T = absolute temperature (K). Gas flow is a function of inlet pressure and temperature. The calibration procedure described in points 2.3.2. to 2.3.7. shall establish the value of the calibration coefficient at measured values of pressure, temperature and air flow. 2.3.2. | The manufacturer’s recommended procedure shall be followed for calibrating electronic portions of the CFV. 2.3.3. | Measurements for flow calibration of the critical-flow venturi are required and the following data shall be found within the limits of precision given: Barometric pressure (corrected) (Pb) ± 0,03 kPa LFE air temperature, flow-meter (ETI) ± 0,15 K Pressure depression upstream of LFE (EPI) ± 0,01 kPa Pressure drop across (EDP) LFE matrix ± 0,0015 kPa Air flow (Qs) ± 0,5 percent CFV inlet depression (PPI) ± 0,02 kPa Temperature at venturi inlet (Tv) ± 0,2 K. 2.3.4. | The equipment shall be set up as shown in Figure Ap 4-4 and checked for leaks. Any leaks between the flow-measuring device and the critical-flow venturi will seriously affect the accuracy of the calibration. Figure Ap4-4 CFV calibration configuration 2.3.5. | The variable-flow restrictor shall be set to the open position, the blower shall be started and the system stabilised. Data from all ins…
(c)added
it shall not change the nature of the exhaust gas;
(d)added
any elastomeric connectors employed shall be as thermally stable as possible and have minimum exposure to the exhaust gases.
3.1. General requirementsdeleted
The total accuracy of the CVS sampling system and analytical system shall be determined by introducing a known mass of a pollutant gas into the system while it is being operated as if during a normal test and then analysing and calculating the pollutant mass according to the formula in point 4, except that the density of propane shall be taken as 1,967 grams per litre at standard conditions. The two techniques described in points 3.2. and 3.3. are known to give sufficient accuracy. The maximum permissible deviation between the quantity of gas introduced and the quantity of gas measured is 5 percent.
1.3.2. Dilution air conditioningadded
The dilution air used for the primary dilution of the exhaust in the CVS tunnel shall be passed through a medium capable of reducing particles in the most penetrating particle size of the filter material by ≥ 99,95 percent, or through a filter of at least class H13 of EN 1822:1998. This represents the specification of High Efficiency Particulate Air (HEPA) filters. The dilution air may be charcoal scrubbed before being passed to the HEPA filter. It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal scrubber, if used. At the vehicle manufacturer’s request, the dilution air may be sampled according to good engineering practice to determine the tunnel contribution to background particulate mass levels, which can then be subtracted from the values measured in the diluted exhaust.
1.3.3. Dilution tunneladded
Provision shall be made for the vehicle exhaust gases and the dilution air to be mixed. A mixing orifice may be used. In order to minimise the effects on the conditions at the exhaust outlet and to limit the drop in pressure inside the dilution-air conditioning device, if any, the pressure at the mixing point shall not differ by more than ± 0,25 kPa from atmospheric pressure. The homogeneity of the mixture in any cross-section at the location of the sampling probe shall not vary by more than ±2 percent from the average of the values obtained for at least five points located at equal intervals on the diameter of the gas stream. For particulate and particle emissions sampling, a dilution tunnel shall be used which:
3.2.1. Metering a constant flow of pure gas (CO o…deleted
3.2.2. | A known quantity of pure gas (CO or C3H8) is fed into the CVS system through the calibrated critical orifice. If the inlet pressure is high enough, the flow-rate (q), which is adjusted by means of the critical-flow orifice, is independent of orifice outlet pressure (critical flow). If deviations exceeding 5 percent occur, the cause of the malfunction shall be determined and corrected. The CVS system is operated as in an exhaust emission test for about five to ten minutes. The gas collected in the sampling bag is analysed by the usual equipment and the results compared to the concentration of the gas samples which was known beforehand.
(a)added
shall consist of a straight tube of electrically-conductive material, which shall be earthed;
(b)added
shall be small enough in diameter to cause turbulent flow (Reynolds number ≥ 4 000 ) and of sufficient length to cause complete mixing of the exhaust and dilution air;
3.3.1. Metering a limited quantity of pure gas (C…deleted
3.3.2. | The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ± 0,01 g. For about five to ten minutes, the CVS system is operated as in a normal exhaust emission test, while CO or propane is injected into the system. The quantity of pure gas involved is determined by means of differential weighing. The gas accumulated in the bag is analysed using the equipment normally used for exhaust-gas analysis. The results are then compared to the concentration figures computed previously.
(c)added
shall be at least 200 mm in diameter;
(d)added
may be insulated.
1.deleted
The chassis dynamometer can be set using the running resistance table instead of the running resistance force obtained by the coast-down methods set out in Appendices 7 or 8. In this table method, the chassis dynamometer shall be set by the reference mass regardless of particular L-category vehicle characteristics.
1.3.4. Suction deviceadded
This device may have a range of fixed speeds to ensure sufficient flow to prevent any water condensation. This result is generally obtained if the flow is either:
2.deleted
The flywheel equivalent inertia mass mref shall be the equivalent inertia mass mi specified in point 4.5.6.1.2. The chassis dynamometer shall be set by the rolling resistance of front wheel ‘a’ and the aerodynamic drag coefficient ‘b’ specified in the following table. Table Ap5-1 Classification of equivalent inertia mass and running resistance used for L-category vehicles Reference mass mref (kg) | Equivalent inertia mass mi (kg) | Rolling resistance of front wheel a (N) | Aero drag coefficient b 20 | 1,8 | 0,0203 30 | 2,6 | 0,0205 40 | 3,5 | 0,0206 50 | 4,4 | 0,0208 60 | 5,3 | 0,0209 70 | 6,8 | 0,0211 80 | 7,0 | 0,0212 90 | 7,9 | 0,0214 100 | 8,8 | 0,0215 110 | 9,7 | 0,0217 120 | 10,6 | 0,0218 130 | 11,4 | 0,0220 140 | 12,3 | 0,0221 150 | 13,2 | 0,0223 160 | 14,1 | 0,0224 170 | 15,0 | 0,0226 180 | 15,8 | 0,0227 190 | 16,7 | 0,0229 200 | 17,6 | 0,0230 210 | 18,5 | 0,0232 220 | 19,4 | 0,0233 230 | 20,2 | 0,0235 240 | 21,1 | 0,0236 250 | 22,0 | 0,0238 260 | 22,9 | 0,0239 270 | 23,8 | 0,0241 280 | 24,6 | 0,0242 290 | 25,5 | 0,0244 300 | 26,4 | 0,0245 310 | 27,3 | 0,0247 320 | 28,2 | 0,0248 330 | 29,0 | 0,0250 340 | 29,9 | 0,0251 350 | 30,8 | 0,0253 360 | 31,7 | 0,0254 370 | 32,6 | 0,0256 380 | 33,4 | 0,0257 390 | 34,3 | 0,0259 400 | 35,2 | 0,0260 410 | 36,1 | 0,0262 420 | 37,0 | 0,0263 430 | 37,8 | 0,0265 440 | 38,7 | 0,0266 450 | 39,6 | 0,0268 460 | 40,5 | 0,0269 470 | 41,4 | 0,0271 480 | 42,2 | 0,0272 490 | 43,1 | 0,0274 500 | 44,0 | 0,0275 At every 10 kg | At every 10…
(a)added
twice the maximum flow of exhaust gas produced by accelerations of the driving cycle; or
(b)added
sufficient to ensure that the CO2 concentration in the dilute exhaust sample bag is less than 3 percent by volume for petrol and diesel, less than 2,2 percent by volume for LPG and less than 1,5 percent by volume for NG/biomethane.
1.3.5. Volume measurement in the primary dilution…added
The method for measuring total dilute exhaust volume incorporated in the constant volume sampler shall be such that measurement is accurate to ± 2 percent under all operating conditions. If the device cannot compensate for variations in the temperature of the mixture of exhaust gases and dilution air at the measuring point, a heat exchanger shall be used to maintain the temperature to within ± 6 K of the specified operating temperature. If necessary, some form of protection for the volume measuring device may be used, e.g. a cyclone separator, bulk stream filter, etc. A temperature sensor shall be installed immediately before the volume measuring device. This sensor shall have an accuracy and a precision of ± 1 K and a response time of 0,1 s at 62 percent of a given temperature variation (value measured in silicone oil). The difference from atmospheric pressure shall be measured upstream and, if necessary, downstream from the volume measuring device. The pressure measurements shall have a precision and an accuracy of ± 0,4 kPa during the test.
1. Description of the ECE R47 test cycledeleted
The ECE R47 test cycle to be used on the chassis dynamometer shall be as depicted in the following graph:
1.4. Recommended system descriptionsadded
Figure Ap 4-1 and Figure Ap 4-2 are schematic drawings of two types of recommended exhaust dilution systems that meet the requirements of this Annex. Since various configurations can produce accurate results, exact conformity with these figures is not essential. Additional components such as instruments, valves, solenoids and switches may be used to provide additional information and coordinate the functions of the component system.
ECE R47-based test cycledeleted
The ECE R47-based test cycle lasts 896 seconds and consists of eight elementary cycles to be carried out without interruption. Each cycle shall comprise of seven driving condition phases (idling, acceleration, steady speed, deceleration, etc.) as set out in points 2 and 3. The truncated vehicle speed trace restricted to maximum 25 km/h is applicable for L1e-A and L1e-B vehicles with a maximum design speed of 25 km/h. 2. | The following elementary cycle characteristic in the shape of the dynamometer-roller speed profile versus test time shall be repeated eight times in total. The cold phase means the first 448 s (four cycles) after cold start of the propulsion and warming-up of the engine. The warm or hot phase is the last 448 s (four cycles), when the propulsion is further warming up and finally running at operating temperature. Table Ap6-1 ECE R47 single cycle characteristic vehicle speed profile versus test time No. of operation Operation Acceleration (m/s2) Roller speed (km/h) Duration of operation (s) Total duration of one cycle (s) 1 Idling — — 8 2 Acceleration full throttle 0-max 8 3 Constant speed full throttle max 57 4 Deceleration 0,56 max -20 65 5 Constant speed — 20 36 101 6 Deceleration …
Positive displacement pump dilution systemadded
The positive displacement pump (PDP) full-flow dilution system satisfies the requirements of this Annex by metering the flow of gas through the pump at constant temperature and pressure. The total volume is measured by counting the revolutions of the calibrated positive displacement pump. The proportional sample is achieved by sampling with pump, flow meter and flow control valve at a constant flow rate. The collecting equipment consists of: A filter (refer to DAF in Figure Ap 4-1) for the dilution air shall be installed, which can be preheated if necessary. This filter shall consist of the following filters in sequence: an optional activated charcoal filter (inlet side) and a high efficiency particulate air (HEPA) filter (outlet side). It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal filter, if used. The purpose of the charcoal filter is to reduce and stabilise the hydrocarbon concentrations of ambient emissions in the dilution air; A transfer tube (TT) by which vehicle exhaust is admitted into a dilution tunnel (DT) in which the exhaust gas and dilution air are mixed homogeneously; The positive displacement pump (PDP), producing a constant-volume flow of the air/exhaust-gas mixture. The PDP revolutions, together with associated temperature and pressure measurement, are used to determine the flow rate; A heat exchanger (HE) of a capacity sufficient to ensure that throughout the test the temperature of the …
1. Description of the test cycledeleted
The ECE R40 test cycle to be used on the chassis dynamometer shall be as depicted in the following graph:
ECE R40-based test cycledeleted
The ECE R40-based test cycle lasts 1 170 seconds and consists of six elementary urban operating cycle cycles to be carried out without interruption. Each elementary urban cycle shall comprise fifteen driving condition phases (idling, acceleration, steady speed, deceleration, etc.) as set out in points 2 and 3. 2. | The following cycle characteristic dynamometer-roller speed profile versus test time shall be repeated 6 times in total. The cold phase means the first 195 s (one elementary urban cycle) after cold start of the propulsion and warming up. The warm phase is the last 975 s (five elementary urban cycles), when the propulsion is further warming up and finally running at operating temperature. 2.1 Table Ap6-2 ECE R40 elementary urban cycle characteristic, vehicle speed profile versus test time No Nature of operation Phase Acceleration (m/s2) Speed (km/h) Duration of each Cumulative time (s) Gear to be used in the case of a manual-shift gearbox Operation (s) Phase (s) 1 Idling 1 0 0 11 11 11 6 s PM + 5 s K (1) 2 Acceleration 2 1,04 0-15 4 4 15 According to manufacturer’s instructions 3 Steady speed 3 0 15 8 8 23 4 Deceleration 4 0,69 15-10 2 5 25 …
Critical-flow venturi dilution systemadded
The use of a critical-flow venturi (CFV) for the full-flow dilution system is based on the principles of flow mechanics for critical flow. The variable mixture flow rate of dilution and exhaust gas is maintained at sonic velocity which is directly proportional to the square root of the gas temperature. Flow is continually monitored, computed and integrated throughout the test. The use of an additional critical-flow sampling venturi ensures the proportionality of the gas samples taken from the dilution tunnel. As pressure and temperature are both equal at the two venturi inlets, the volume of the gas flow diverted for sampling is proportional to the total volume of diluted exhaust-gas mixture produced, and thus the requirements of this Annex are met. The collecting equipment consists of: A filter (DAF) for the dilution air which can be preheated if necessary. This filter shall consist of the following filters in sequence: an optional activated charcoal filter (inlet side) and a high efficiency particulate air (HEPA) filter (outlet side). It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal filter, if used. The purpose of the charcoal filter is to reduce and stabilise the hydrocarbon concentrations of ambient emissions in the dilution air; A mixing chamber (MC) in which exhaust gas and air are mixed homogeneously and which may be located close to the vehicle so that the length of the transfer tube (TT) is minimis…
1. Description of the test cycledeleted
The WMTC stage 2 to be used on the chassis dynamometer shall be as depicted in the following graph:
2.1. General requirementsadded
The CVS system shall be calibrated by using an accurate flow-meter and a restricting device. The flow through the system shall be measured at various pressure readings and the control parameters of the system measured and related to the flows. The flow-meter shall be dynamic and suitable for the high flow-rate encountered in CVS testing. The device shall be of certified accuracy traceable to an approved national or international standard. 2.1.1. | Various types of flow-meter may be used, e.g. calibrated venturi, laminar flow-meter, calibrated turbine-meter, provided that they are dynamic measurement systems and can meet the requirements of point 1.3.5. of this Appendix. 2.1.2. | The following points give details of methods of calibrating PDP and CFV units, using a laminar flow-meter which gives the required accuracy, together with a statistical check on the calibration validity.
2.2. Calibration of the positive displacement pum…added
2.2.1. | The following calibration procedure outlines the equipment, the test configuration and the various parameters that are measured to establish the flow-rate of the CVS pump. All the parameters relating to the pump are simultaneously measured with the parameters relating to the flow-meter which is connected in series with the pump. The calculated flow rate (given in m3/min at pump inlet, absolute pressure and temperature) can then be plotted against a correlation function that is the value of a specific combination of pump parameters. The linear equation that relates the pump flow and the correlation function is then determined. If a CVS has a multiple speed drive, a calibration shall be performed for each range used. 2.2.2. | This calibration procedure is based on the measurement of the absolute values of the pump and flow-meter parameters that relate to the flow rate at each point. Three conditions shall be maintained to ensure the accuracy and integrity of the calibration curve: 2.2.2.1. The pump pressures shall be measured at tappings on the pump rather than at the external piping on the pump inlet and outlet. Pressure taps that are mounted at the top centre and bottom centre of the pump drive head plate are exposed to the actual pump cavity pressures and therefore reflect the absolute pressure differentials; 2.2.2.2. Temperature stability shall be maintained during the calibration. The laminar flow-meter is sensitive to inlet temperature …
WMTC stage 2deleted
1.1. | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The WMTC stage 2 lasts 1 800 seconds and consists of three parts to be carried out without interruption. The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.). are set out in the following points and tables.
2.3. Calibration of the critical-flow venturi (CF…added
2.3.1. | Calibration of the CFV is based on the flow equation for a critical-flow venturi: Equation Ap 4-4: where: Qs = flow; Kv = calibration coefficient; P = absolute pressure (kPa); T = absolute temperature (K). Gas flow is a function of inlet pressure and temperature. The calibration procedure described in points 2.3.2. to 2.3.7. shall establish the value of the calibration coefficient at measured values of pressure, temperature and air flow. 2.3.2. | The manufacturer’s recommended procedure shall be followed for calibrating electronic portions of the CFV. 2.3.3. | Measurements for flow calibration of the critical-flow venturi are required and the following data shall be found within the limits of precision given: Barometric pressure (corrected) (Pb) ± 0,03 kPa LFE air temperature, flow-meter (ETI) ± 0,15 K Pressure depression upstream of LFE (EPI) ± 0,01 kPa Pressure drop across (EDP) LFE matrix ± 0,0015 kPa Air flow (Qs) ± 0,5 percent CFV inlet depression (PPI) ± 0,02 kPa Temperature at venturi inlet (Tv) ± 0,2 K. 2.3.4. | The equipment shall be set up as shown in Figure Ap 4-4 and checked for leaks. Any leaks between the flow-measuring device and the critical-flow venturi will seriously affect the accuracy of the calibration. Figure Ap4-4 CFV calibration configuration 2.3.5. | The variable-flow restrictor shall be set to the open position, the blower shall be started and the system stabilised. Data from all instruments shall be recorded…
3.1. General requirementsadded
The total accuracy of the CVS sampling system and analytical system shall be determined by introducing a known mass of a pollutant gas into the system while it is being operated as if during a normal test and then analysing and calculating the pollutant mass according to the formula in point 4, except that the density of propane shall be taken as 1,967 grams per litre at standard conditions. The two techniques described in points 3.2. and 3.3. are known to give sufficient accuracy. The maximum permissible deviation between the quantity of gas introduced and the quantity of gas measured is 5 percent.
WMTC stage 2, part 1deleted
2.1 | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, cycle part 1 is set out in the following tables. 2.2.1. Table Ap6-3 WMTC stage 2, cycle part 1, reduced speed for vehicle classes 1 and 2-1, 0 to 180 s. time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,0 X 9 0,0 X 10 0,0 X 11 0,0 X 12 0,0 X 13 0,0 X 14 0,0 X 15 0,0 X 16 0,0 X 17 0,0 X 18 0,0 X …
3.2.1. Metering a constant flow of pure gas (CO o…added
3.2.2. | A known quantity of pure gas (CO or C3H8) is fed into the CVS system through the calibrated critical orifice. If the inlet pressure is high enough, the flow-rate (q), which is adjusted by means of the critical-flow orifice, is independent of orifice outlet pressure (critical flow). If deviations exceeding 5 percent occur, the cause of the malfunction shall be determined and corrected. The CVS system is operated as in an exhaust emission test for about five to ten minutes. The gas collected in the sampling bag is analysed by the usual equipment and the results compared to the concentration of the gas samples which was known beforehand.
WMTC stage 2, part 2deleted
3.1. | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, part 2 is set out in the following tables. 3.1.1. Table Ap6-11 WMTC stage 2, cycle part 2, reduced speed for vehicle class 2-1, 0 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,0 X 9 2,3 X 10 7,3 X 11 13,6 X 12 18,9 X 13 23,6 X 14 27,8 X 15 31,8 X 16 35,6 X 17 39,3 X 18 42,7 X …
3.3.1. Metering a limited quantity of pure gas (C…added
3.3.2. | The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ± 0,01 g. For about five to ten minutes, the CVS system is operated as in a normal exhaust emission test, while CO or propane is injected into the system. The quantity of pure gas involved is determined by means of differential weighing. The gas accumulated in the bag is analysed using the equipment normally used for exhaust-gas analysis. The results are then compared to the concentration figures computed previously.
WMTC stage 2, part 3deleted
4.1 | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, part 3 is set out in the following tables. 4.1.1. Table Ap6-19 WMTC stage 2, cycle part 3, reduced speed for vehicle class 3-1, 1 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,9 X 9 3,2 X 10 7,3 X 11 12,4 X 12 17,9 X 13 23,5 X 14 29,1 X 15 34,3 X 16 38,6 X 17 41,6 X 18 43,9 X …
1.added
The chassis dynamometer can be set using the running resistance table instead of the running resistance force obtained by the coast-down methods set out in Appendices 7 or 8. In this table method, the chassis dynamometer shall be set by the reference mass regardless of particular L-category vehicle characteristics.
2.added
The flywheel equivalent inertia mass mref shall be the equivalent inertia mass mi specified in point 4.5.6.1.2. The chassis dynamometer shall be set by the rolling resistance of front wheel ‘a’ and the aerodynamic drag coefficient ‘b’ specified in the following table. Table Ap5-1 Classification of equivalent inertia mass and running resistance used for L-category vehicles Reference mass mref (kg) | Equivalent inertia mass mi (kg) | Rolling resistance of front wheel a (N) | Aero drag coefficient b 20 | 1,8 | 0,0203 30 | 2,6 | 0,0205 40 | 3,5 | 0,0206 50 | 4,4 | 0,0208 60 | 5,3 | 0,0209 70 | 6,8 | 0,0211 80 | 7,0 | 0,0212 90 | 7,9 | 0,0214 100 | 8,8 | 0,0215 110 | 9,7 | 0,0217 120 | 10,6 | 0,0218 130 | 11,4 | 0,0220 140 | 12,3 | 0,0221 150 | 13,2 | 0,0223 160 | 14,1 | 0,0224 170 | 15,0 | 0,0226 180 | 15,8 | 0,0227 190 | 16,7 | 0,0229 200 | 17,6 | 0,0230 210 | 18,5 | 0,0232 220 | 19,4 | 0,0233 230 | 20,2 | 0,0235 240 | 21,1 | 0,0236 250 | 22,0 | 0,0238 260 | 22,9 | 0,0239 270 | 23,8 | 0,0241 280 | 24,6 | 0,0242 290 | 25,5 | 0,0244 300 | 26,4 | 0,0245 310 | 27,3 | 0,0247 320 | 28,2 | 0,0248 330 | 29,0 | 0,0250 340 | 29,9 | 0,0251 350 | 30,8 | 0,0253 360 | 31,7 | 0,0254 370 | 32,6 | 0,0256 380 | 33,4 | 0,0257 390 | 34,3 | 0,0259 400 | 35,2 | 0,0260 410 | 36,1 | 0,0262 420 | 37,0 | 0,0263 430 | 37,8 | 0,0265 440 | 38,7 | 0,0266 450 | 39,6 | 0,0268 460 | 40,5 | 0,0269 470 | 41,4 | 0,0271 480 | 42,2 | 0,0272 490 | 43,1 | 0,0274 500 | 44,0 | 0,0275 At every 10 kg | At every 10…
1. Description of the WMTC stage 3 test cycle f…deleted
The WMTC stage 3 to be used on the chassis dynamometer shall be as depicted in the following graph for (sub-)category L3e, L4e, L5e-A, L7e-A, L7e-B and L7e-C vehicles:
WMTC stage 3 for L3e, L4e, L5e-A, L7e-A, L7e-B an…deleted
The ‘revised WMTC’ also referred to as ‘WMTC stage 3’ as shown in Figure Ap 6-9 is applicable for L3e, L4e, L5e-A, L7e-A, L7e-B and L7e-C vehicles and the vehicle speed trace of WMTC stage 3 is equivalent to WMTC stages 1 and 2. The WMTC stage 3 lasts 1 800 seconds and consists of two parts for vehicles with a low maximum design vehicle speed and three parts for the other L-category vehicles to be carried out without interruption if allowed by maximum vehicle speed limitation. The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.) of WMTC stage 3 are laid down in chapter 3, which sets out the detailed vehicle speed trace of the WMTC stage 2.
2. Description of the WMTC stage 3 for L1e-A, L…deleted
The WMTC stage 3 to be used on the chassis dynamometer shall be a depicted in the following graph for (sub-)category L1e-A, L1e-B, L2e, L6e-A and L6e-B vehicles with a low maximum vehicle design speed:
1. Description of the ECE R47 test cycleadded
The ECE R47 test cycle to be used on the chassis dynamometer shall be as depicted in the following graph:
WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A …deleted
2.1 | The cold and warm vehicle speed traces are identical.
ECE R47-based test cycleadded
The ECE R47-based test cycle lasts 896 seconds and consists of eight elementary cycles to be carried out without interruption. Each cycle shall comprise of seven driving condition phases (idling, acceleration, steady speed, deceleration, etc.) as set out in points 2 and 3. The truncated vehicle speed trace restricted to maximum 25 km/h is applicable for L1e-A and L1e-B vehicles with a maximum design speed of 25 km/h. 2. | The following elementary cycle characteristic in the shape of the dynamometer-roller speed profile versus test time shall be repeated eight times in total. The cold phase means the first 448 s (four cycles) after cold start of the propulsion and warming-up of the engine. The warm or hot phase is the last 448 s (four cycles), when the propulsion is further warming up and finally running at operating temperature. Table Ap6-1 ECE R47 single cycle characteristic vehicle speed profile versus test time No. of operation Operation Acceleration (m/s2) Roller speed (km/h) Duration of operation (s) Total duration of one cycle (s) 1 Idling — — 8 2 Acceleration full throttle 0-max 8 3 Constant speed full throttle max 57 4 Deceleration 0,56 max -20 65 5 Constant speed — 20 36 101 6 Deceleration …
1. Description of the test cycleadded
The ECE R40 test cycle to be used on the chassis dynamometer shall be as depicted in the following graph:
WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A …deleted
3.1. | The vehicle speed trace WMTC stage 3 shown in Figure Ap 6-10 is applicable for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B (sub-)category vehicles and is equivalent to the vehicle speed trace WMTC stages 1 and 2, part 1 for class 1 vehicles, driven once cold followed by the same vehicle speed driven with a warmed-up propulsion. The WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B (sub-)category vehicles lasts 1 200 seconds and consists of two equivalent parts to be carried out without interruption. 3.2. | The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.) of WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B vehicles are set out in the following points and tables. 3.2.1. Table Ap6-27 WMTC stage 3, part 1, class 1, applicable for L1e-A and L1e-B (vmax ≤ 25 km/h) sub-category vehicles, cold or warm, 0 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0 X 1 0 X 2 0 X 3 0 X 4 0 X 5 0 X 6 0 X 7 0 X 8 0 X …
ECE R40-based test cycleadded
The ECE R40-based test cycle lasts 1 170 seconds and consists of six elementary urban operating cycle cycles to be carried out without interruption. Each elementary urban cycle shall comprise fifteen driving condition phases (idling, acceleration, steady speed, deceleration, etc.) as set out in points 2 and 3. 2. | The following cycle characteristic dynamometer-roller speed profile versus test time shall be repeated 6 times in total. The cold phase means the first 195 s (one elementary urban cycle) after cold start of the propulsion and warming up. The warm phase is the last 975 s (five elementary urban cycles), when the propulsion is further warming up and finally running at operating temperature. 2.1 Table Ap6-2 ECE R40 elementary urban cycle characteristic, vehicle speed profile versus test time No Nature of operation Phase Acceleration (m/s2) Speed (km/h) Duration of each Cumulative time (s) Gear to be used in the case of a manual-shift gearbox Operation (s) Phase (s) 1 Idling 1 0 0 11 11 11 6 s PM + 5 s K (*1) 2 Acceleration 2 1,04 0-15 4 4 15 According to manufacturer’s instructions 3 Steady speed 3 0 15 8 8 23 4 Deceleration 4 0,69 15-10 2 5 25 …
1. Requirements for the riderdeleted
1.1. The rider shall wear a well-fitting (one-piece) suit or similar clothing and a protective helmet, eye protection, boots and gloves. 1.2. The rider, dressed and equipped as described in point 1.1., shall have a mass of 75 kg ± 5 kg and be 1,75 m ± 0,05 m tall. 1.3. The rider shall be seated on the seat provided, with his feet on the footrests and his arms extended normally. This position shall allow the rider to have proper control of the vehicle at all times during the tests.
2. Requirement for the road and ambient conditi…deleted
2.1. The test road shall be flat, level, straight and smoothly paved. The road surface shall be dry and free of obstacles or wind barriers that might impede the measurement of the running resistance. The slope of the surface shall not exceed 0,5 percent between any two points at least 2 m apart. 2.2. During data collecting periods, the wind shall be steady. The wind speed and the direction of the wind shall be measured continuously or with adequate frequency at a location where the wind force during coast-down is representative. 2.3. The ambient conditions shall be within the following limits:
1. Description of the test cycleadded
The WMTC stage 2 to be used on the chassis dynamometer shall be as depicted in the following graph:
—deleted
maximum wind speed: 3 m/s
—deleted
maximum wind speed for gusts: 5 m/s
WMTC stage 2added
1.1. | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The WMTC stage 2 lasts 1 800 seconds and consists of three parts to be carried out without interruption. The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.). are set out in the following points and tables.
—deleted
average wind speed, parallel: 3 m/s
—deleted
average wind speed, perpendicular: 2 m/s
—deleted
maximum relative humidity: 95 percent
WMTC stage 2, part 1added
2.1 | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, cycle part 1 is set out in the following tables. 2.2.1. Table Ap6-3 WMTC stage 2, cycle part 1, reduced speed for vehicle classes 1 and 2-1, 0 to 180 s. time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,0 X 9 0,0 X 10 0,0 X 11 0,0 X 12 0,0 X 13 0,0 X 14 0,0 X 15 0,0 X 16 0,0 X 17 0,0 X 18 0,0 X …
—deleted
air temperature: 278,2 K to 308,2 K 2.4. Standard ambient conditions shall be as follows:
—deleted
pressure, P0: 100 kPa
—deleted
temperature, T0: 293,2 K
WMTC stage 2, part 2added
3.1. | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, part 2 is set out in the following tables. 3.1.1. Table Ap6-11 WMTC stage 2, cycle part 2, reduced speed for vehicle class 2-1, 0 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,0 X 9 2,3 X 10 7,3 X 11 13,6 X 12 18,9 X 13 23,6 X 14 27,8 X 15 31,8 X 16 35,6 X 17 39,3 X 18 42,7 X …
—deleted
relative air density, d0: 0,9197
—deleted
air volumetric mass, ρ0: 1,189 kg/m3 2.5. The relative air density when the vehicle is tested, calculated in accordance with the formula Ap 7-1, shall not differ by more than 7,5 percent from the air density under the standard conditions. 2.6. The relative air density, dT, shall be calculated using the following formula: Equation Ap 7-1: where: d0 is the reference relative air density at reference conditions (1,189 kg/m3) pT is the mean ambient pressure during the test, in kPa; p0 is the reference ambient pressure (101,3 kPa); TT is the mean ambient temperature during test, in K; T0 is the reference ambient temperature (293,2 K).
3. Condition of the test vehicledeleted
3.1. | The test vehicle shall comply with the conditions described in point 1 of Appendix 8. 3.2. | When installing the measuring instruments on the test vehicle, care shall be taken to minimise their effects on the distribution of the load across the wheels. When installing the speed sensor outside the vehicle, care shall be taken to minimise the additional aerodynamic loss. 3.3. | ChecksThe following checks shall be made in accordance with the manufacturer’s specifications for the use considered: wheels, wheel rims, tyres (make, type and pressure), front axle geometry, brake adjustment (elimination of parasitic drag), lubrication of front and rear axles, adjustment of the suspension and vehicle ground clearance, etc. Check that during freewheeling, there is no electrical braking.
WMTC stage 2, part 3added
4.1 | The WMTC stage 2 includes the same vehicle speed trace as WMTC stage 1 with supplemental gear shift prescriptions. The characteristic roller speed versus test time of WMTC stage 2, part 3 is set out in the following tables. 4.1.1. Table Ap6-19 WMTC stage 2, cycle part 3, reduced speed for vehicle class 3-1, 1 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0,0 X 1 0,0 X 2 0,0 X 3 0,0 X 4 0,0 X 5 0,0 X 6 0,0 X 7 0,0 X 8 0,9 X 9 3,2 X 10 7,3 X 11 12,4 X 12 17,9 X 13 23,5 X 14 29,1 X 15 34,3 X 16 38,6 X 17 41,6 X 18 43,9 X …
4. Specified coast-down speedsdeleted
4.1. The coast-down times must be measured between v1 and v2 as specified in Table Ap 7-1, depending on the vehicle class as defined in point 4.3. of Annex II. 4.2. Table Ap7-1 Coast-down time measurement beginning speed and ending speed Maximum design speed (km/h) | Specified target vehicle speed vj in (km/h) | v1 in (km/h) | v2 in (km/h) ≤ 25 km/h 20 | 25 | 15 15 | 20 | 10 10 | 15 | 5 ≤ 45 km/h 40 | 45 | 35 30 | 35 | 25 20 | 25 | 15 45 < maximum design speed ≤ 130 km/h and > 130 km/h 120 | 130*/ | 110 100 | 110*/ | 90 80 | 90*/ | 70 60 | 70 | 50 40 | 45 | 35 20 | 25 | 15 4.3. When the running resistance is verified in accordance with point 5.2.2.3.2., the test can be executed at vj ± 5 km/h, provided that the coast-down time accuracy referred to in point 4.5.7. of Annex II is ensured.
5. Measurement of coast-down timedeleted
5.1. After a warm-up period, the vehicle shall be accelerated to the coast-down starting speed, at which point the coast-down measurement procedure shall be started. 5.2. Since shifting the transmission to neutral can be dangerous and complicated by the construction of the vehicle, the coasting may be performed solely with the clutch disengaged. Vehicles that have no means of cutting the transmitted engine power off prior to coasting may be towed until they reach the coast-down starting speed. When the coast-down test is reproduced on the chassis dynamometer, the drive train and clutch shall be in the same condition as during the road test. 5.3. The vehicle steering shall be altered as little as possible and the brakes shall not be operated until the end of the coast-down measurement period. 5.4. The first coast-down time Δtai corresponding to the specified speed vj shall be measured as the time taken for the vehicle to decelerate from vj + Δv to vj – Δv. 5.5. The procedure described in points 5.1. to 5.4. shall be repeated in the opposite direction to measure the second coast-down time Δtbi. 5.6. The average Δti of the two coast-down times Δtai and vtbi shall be calculated using the following equation: Equation Ap 7-2: 5.7. At least four tests shall be performed and the average coast-down time ΔTj calculated using the following equation: Equation Ap 7-3: 5.8. Tests shall be performed until the statistical accuracy P is equal to or less than 3 percent (P ≤ 3 percent). The st…
1. Description of the WMTC stage 3 test cycle f…added
The WMTC stage 3 to be used on the chassis dynamometer shall be as depicted in the following graph for (sub-)category L3e, L4e, L5e-A, L7e-A, L7e-B and L7e-C vehicles:
6.1. Calculation of running resistance forcedeleted
6.1.1. The running resistance force Fj, in Newton, at the specified speed vj shall be calculated using the following equation: Equation Ap7-6: where: mref = reference mass (kg); Δv = vehicle speed deviation (km/h); Δt = calculated coast down time difference (s); 6.1.2. The running resistance force Fj shall be corrected in accordance with point 6.2.
WMTC stage 3 for L3e, L4e, L5e-A, L7e-A, L7e-B an…added
The ‘revised WMTC’ also referred to as ‘WMTC stage 3’ as shown in Figure Ap 6-9 is applicable for L3e, L4e, L5e-A, L7e-A, L7e-B and L7e-C vehicles and the vehicle speed trace of WMTC stage 3 is equivalent to WMTC stages 1 and 2. The WMTC stage 3 lasts 1 800 seconds and consists of two parts for vehicles with a low maximum design vehicle speed and three parts for the other L-category vehicles to be carried out without interruption if allowed by maximum vehicle speed limitation. The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.) of WMTC stage 3 are laid down in chapter 3, which sets out the detailed vehicle speed trace of the WMTC stage 2.
6.2. Running resistance curve fittingdeleted
The running resistance force, F, shall be calculated as follows: 6.2.1. The following equation shall be fitted to the data set of Fj and vj obtained in points 4 and 6.1. respectively by linear regression to determine the coefficients f0 and f2, Equation Ap7-7: 6.2.2. The coefficients f0 and f2 thus determined shall be corrected to the standard ambient conditions using the following equations: Equation Ap7-8: Equation Ap7-9: where: K0 shall be determined on the basis of the empirical data for the particular vehicle and tyre tests or shall be assumed as follows, if the information is not available: .
2. Description of the WMTC stage 3 for L1e-A, L…added
The WMTC stage 3 to be used on the chassis dynamometer shall be a depicted in the following graph for (sub-)category L1e-A, L1e-B, L2e, L6e-A and L6e-B vehicles with a low maximum vehicle design speed:
6.3. Target running resistance force F* for chass…deleted
The target running resistance force F*(v0) on the chassis dynamometer at the reference vehicle speed v0, in Newton, is determined using the following equation: Equation Ap7-10:
WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A …added
2.1 | The cold and warm vehicle speed traces are identical.
1.1. Running-indeleted
The test vehicle shall be in normal running order and adjustment after having been run in for at least 300 km. The tyres shall be run in at the same time as the vehicle or shall have a tread depth within 90 and 50 percent of the initial tread depth.
1.2. Checksdeleted
The following checks shall be made in accordance with the manufacturer’s specifications for the use considered: wheels, wheel rims, tyres (make, type and pressure), front axle geometry, brake adjustment (elimination of parasitic drag), lubrication of front and rear axles, adjustment of the suspension and vehicle ground clearance, etc. Check that during freewheeling, there is no electrical braking.
WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A …added
3.1. | The vehicle speed trace WMTC stage 3 shown in Figure Ap 6-10 is applicable for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B (sub-)category vehicles and is equivalent to the vehicle speed trace WMTC stages 1 and 2, part 1 for class 1 vehicles, driven once cold followed by the same vehicle speed driven with a warmed-up propulsion. The WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B (sub-)category vehicles lasts 1 200 seconds and consists of two equivalent parts to be carried out without interruption. 3.2. | The characteristic driving conditions (idling, acceleration, steady speed, deceleration, etc.) of WMTC stage 3 for L1e-A, L1e-B, L2e, L5e-B, L6e-A and L6e-B vehicles are set out in the following points and tables. 3.2.1. Table Ap6-27 WMTC stage 3, part 1, class 1, applicable for L1e-A and L1e-B (vmax ≤ 25 km/h) sub-category vehicles, cold or warm, 0 to 180 s time in s roller speed in km/h phase indicators stop acc cruise dec 0 0 X 1 0 X 2 0 X 3 0 X 4 0 X 5 0 X 6 0 X 7 0 X 8 0 X …
1.3. Preparation for the testdeleted
1.3.1. The test vehicle shall be loaded to its test mass including driver and measurement equipment, spread in a uniform way in the loading areas. 1.3.2. The windows of the vehicle shall be closed. Any covers for air conditioning systems, headlamps, etc. shall be closed. 1.3.3. The test vehicle shall be clean, properly maintained and used. 1.3.4. Immediately before the test, the vehicle shall be brought to the normal running temperature in an appropriate manner. 1.3.5. When installing the measuring instruments on the test vehicle, care shall be taken to minimise their effects on the distribution of the load across the wheels. When installing the speed sensor outside the test vehicle, care shall be taken to minimise the additional aerodynamic loss.
2. Specified vehicle speed vdeleted
The specified speed is required for determining the running resistance at the reference speed from the running resistance curve. To determine the running resistance as a function of vehicle speed in the vicinity of the reference speed v0, running resistances shall be measured at the specified speed v. At least four to five points indicating the specified speeds, along with the reference speeds, shall be measured. The calibration of the load indicator referred to in point 2.2. of Appendix 3 shall be performed at the applicable reference vehicle speed (vj) referred to in Table Ap8-1. Table Ap8-1 Specified vehicle speeds to perform the coast-down time test as well as the designated reference vehicle speed vj depending on the maximum design speed (vmax) of the vehicle Category vmax | Vehicle speed (km/h) > 130 | 120 (2) | 100 | 80 (1) | 60 | 40 | 20 130-100 | 90 | 80 (1) | 60 | 40 | 20 | — 100-70 | 60 | 50 (1) | 40 | 30 | 20 | — 70-45 | 50 (2) | 40 (1) | 30 | 20 | — | — 45-25 | 40 | 30 (1) | 20 ≤ 25 km/h | 20 | 15 (1) | 10 (*1) Applicable reference vehicle speed vj (*2) if the vehicle speed can be attained by the vehicle.
1.1.added
The rider shall wear a well-fitting (one-piece) suit or similar clothing and a protective helmet, eye protection, boots and gloves.
3.1.1. Measurement equipment and accuracydeleted
The margin of measurement error shall be less than 0,1 second for time and less than ± 0,5 km/h for speed. Bring the vehicle and the chassis dynamometer to the stabilised operating temperature, in order to approximate the road conditions.
1.2.added
The rider, dressed and equipped as described in point 1.1., shall have a mass of 75 kg ± 5 kg and be 1,75 m ± 0,05 m tall.
3.1.2. Test proceduredeleted
3.1.2.1. | Accelerate the vehicle to a speed of 5 km/h greater than the speed at which test measurement begins. 3.1.2.2. | Put the gearbox to neutral or disconnect the power supply. 3.1.2.3. | Measure the time t1 taken by the vehicle to decelerate from: to where: Δv < 5 km/h for nominal vehicle speed < 50 km/h; Δv < 10 km/h for nominal vehicle speed > 50 km/h. 3.1.2.4. | Carry out the same test in the opposite direction, measuring time t2. 3.1.2.5. | Take the average ti of the two times t1 and t2. 3.1.2.6. | Repeat these tests until the statistical accuracy (p) of the average: Equation Ap 8-1: The statistical accuracy (p) is defined by: Equation Ap 8-2: is no more than 4 percent (p ≤ 4 percent).where: t is the coefficient in Table Ap 8-2; s is the standard deviation. Equation Ap 8-3: n is the number of tests Table Ap8-2 Factors t and t/√n depending on the number of coast-down tests performed n 4 5 6 7 8 9 10 t 3,2 2,8 2,6 2,5 2,4 2,3 2,3 t/√n 1,6 1,25 1,06 0,94 0,85 0,77 0,73 n | 4 | 5 | 6 | 7 | 8 | 9 | 10 t | 3,2 | 2,8 | 2,6 | 2,5 | 2,4 | 2,3 | 2,3 t/√n | 1,6 | 1,25 | 1,06 | 0,94 | 0,85 | 0,77 | 0,73 3.1.2.7. | Calculation of the running resistance forceThe running resistance force F at the specified vehicle speeds v is cal…
1.3.added
The rider shall be seated on the seat provided, with his feet on the footrests and his arms extended normally. This position shall allow the rider to have proper control of the vehicle at all times during the tests.
3.2. Setting of the chassis dynamometerdeleted
The purpose of this procedure is to simulate on the dynamometer the total road load power at a given speed.
3.2.1. Measurement equipment and accuracydeleted
The measuring equipment shall be similar to that used on the test track and shall comply with point 4.5.7. of Annex II and point 1.3.5 of this Appendix.
2.1.added
The test road shall be flat, level, straight and smoothly paved. The road surface shall be dry and free of obstacles or wind barriers that might impede the measurement of the running resistance. The slope of the surface shall not exceed 0,5 percent between any two points at least 2 m apart.
3.2.2. Test proceduredeleted
3.2.2.1. Install the vehicle on the chassis dynamometer. 3.2.2.2. Adjust the tyre pressure (cold) of the driving wheels as required for the chassis dynamometer. 3.2.2.3. Adjust the equivalent inertia mass of the chassis dynamometer, in accordance with Table Ap8-4. 3.2.2.3.1. Table Ap8-4 Determination of equivalent inertia mass for an L-category vehicle equipped with two or more wheels on the powered axles Reference mass (mref) (kg) | Equivalent inertia mass (mi) (kg) mref ≤ 105 | 100 105 < mref ≤ 115 | 110 115 < mref ≤ 125 | 120 125 < mref ≤ 135 | 130 135 < mref ≤ 150 | 140 150 < mref ≤ 165 | 150 165 < mref ≤ 185 | 170 185 < mref ≤ 205 | 190 205 < mref ≤ 225 | 210 225 < mref ≤ 245 | 230 245 < mref ≤ 270 | 260 270 < mref ≤ 300 | 280 300 < mref ≤ 330 | 310 330 < mref ≤ 360 | 340 360 < mref ≤ 395 | 380 395 < mref ≤ 435 | 410 435 < mref ≤ 480 | 450 480 < mref ≤ 540 | 510 540 < mref ≤ 600 | 570 600 < mref ≤ 650 | 620 650 < mref ≤ 710 | 680 710 < mref ≤ 770 | 740 770 < mref ≤ 820 | 800 820 < mref ≤ 880 | 850 880 < mref ≤ 940 | 910 940 < mref ≤ 990 | 960 990 < mref ≤ 1 050 | 1 020 1 050 < mref ≤ 1 110 | 1 080 1 110 < mref ≤ 1 160 | 1 130 1 160 < mref ≤ 1 220 | 1 190 1 220 < mref ≤ 1 280 | 1 250 1 280 < mref ≤ 1 330 | 1 300 1 330 < mref ≤ 1 390 | 1 360 1 390 < mref ≤ 1 450 | 1 420 1 450 < mref ≤ 1 500 | 1 470 1 500 < mref ≤ 1 560 | 1 530 1 560 < mref ≤ 1 620 | 1 590 1 620 < mref ≤ 1 670 | 1 640 1 670 < mref ≤ 1 730 | 1 700 1 730 < mref ≤ 1 790 | 1 760 1 790 < mref ≤ 1 870 | 1 810 …
2.2.added
During data collecting periods, the wind shall be steady. The wind speed and the direction of the wind shall be measured continuously or with adequate frequency at a location where the wind force during coast-down is representative.
2.3.added
The ambient conditions shall be within the following limits:
0. Introductiondeleted
This explanatory note explains matters specified or described in this Regulation, including its Annexes or Appendices, and matters related thereto with regard to the gearshift procedure.
1. Approachdeleted
1.1. The development of the gearshift procedure was based on an analysis of the gearshift points in the in-use data. In order to establish generalised correlations between technical specifications of the vehicles and gearshift speeds, the engine speeds were normalised to the utilisable band between rated speed and idling speed. 1.2. In a second step, the end speeds (vehicle speed as well as normalised engine speed) for upshifts and downshifts were determined and recorded in a separate table. The averages of these speeds for each gear and vehicle were calculated and correlated with the vehicles’ technical specifications. 1.3. The results of these analyses and calculations can be summarised as follows:
(a)deleted
the gearshift behaviour is engine-speed-related rather than vehicle-speed-related;
(b)deleted
the best correlation between gearshift speeds and technical data was found for normalised engine speeds and the power-to-mass ratio (maximum continuous rated power/(mass in running order + 75 kg));
(c)deleted
the residual variations cannot be explained by other technical data or by different drive train ratios. They are most probably due to differences in traffic conditions and individual driver behaviour;
(d)deleted
the best approximation between gearshift speeds and power-to-mass ratio was found for exponential functions;
(e)deleted
the gearshift mathematical function for the first gear is significantly lower than for all other gears;
2.4.added
Standard ambient conditions shall be as follows:
(f)deleted
the gearshift speeds for all other gears can be approximated by one common mathematical function;
(g)deleted
no differences were found between five-speed and six-speed gearboxes;
(h)deleted
gearshift behaviour in Japan is significantly different from the equal-type gearshift behaviour in the European Union (EU) and in the United States of America (USA). 1.4. In order to find a balanced compromise between the three regions, a new approximation function for normalised upshift speeds versus power-to-mass ratio was calculated as a weighted average of the EU/USA curve (with 2/3 weighting) and the Japanese curve (with 1/3 weighting), resulting in the following equations for normalised engine upshift speeds: Equation Ap9-1: Normalised upshift speed in 1st gear (gear 1) Equation Ap9-2: Normalised upshift speed in gears > 1
2. Calculation exampledeleted
2.1 | Figure Ap 9-1 shows an example of gearshift use for a small vehicle: (a) the lines in bold show the gear use for acceleration phases; (b) the dotted lines show the downshift points for deceleration phases; (c) in the cruising phases, the whole speed range between downshift speed and upshift speed may be used. 2.2 | Where vehicle speed increases gradually during cruise phases, upshift speeds (v1—2, v2—3and vi—i+1) in km/h may be calculated using the following equations: Equation Ap9-3: Equation Ap9-4: Equation Ap9-5: , i = 3 to ng Figure Ap9-1 Example of a gearshift sketch — Gear use during deceleration and cruise phases Gear use during acceleration phases In order to allow the technical service more flexibility and to ensure driveability, the gearshift regression functions should be considered as lower limits. Higher engine speeds are permitted in any cycle phase.
3. Phase indicatorsdeleted
3.1 | In order to avoid different interpretations in the application of the gearshift equations and thus to improve the comparability of the test, fixed-phase indicators are assigned to the speed pattern of the cycles. The specification of the phase indicators is based on the definition from the Japan Automobile Research Institute (JARI) of the four driving modes as shown in the following table: Table Ap9-1 Definition of driving modes 4 modes Definition Idle mode vehicle speed < 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) Acceleration mode acceleration > 0,5 km/h/s (0,139 m/s2) Deceleration mode acceleration < - 0,5 km/h/s (- 0,139 m/s2) Cruise mode vehicle speed ≥ 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) 4 modes | Definition Idle mode | vehicle speed < 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) Acceleration mode | acceleration > 0,5 km/h/s (0,139 m/s2) Deceleration mode | acceleration < - 0,5 km/h/s (- 0,139 m/s2) Cruise mode | vehicle speed ≥ 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) 3.2 | The indicators were then modified in order to avoid frequent changes during relatively homogeneous cycle parts and thus improve driveability. Figure Ap9-2 shows an example from cycle part 1. Figure Ap9-2 Example for modified phase indicators
2.5.added
The relative air density when the vehicle is tested, calculated in accordance with the formula Ap 7-1, shall not differ by more than 7,5 percent from the air density under the standard conditions.
4. Calculation exampledeleted
4.1. An example of input data necessary for the calculation of shift speeds is shown in Table Ap 9-2. The upshift speeds for acceleration phases for first gear and higher gears are calculated using Equations 9-1 and 9-2. The denormalisation of engine speeds can be performed using the equation . 4.2. The downshift speeds for deceleration phases can be calculated using Equations 9-3 and 9-4. The ndv values in Table Ap 9-2 can be used as gear ratios. These values can also be used to calculate the corresponding vehicle speeds ( . The results are shown in Tables Ap9-3 and Ap9-4. 4.3. Additional analyses and calculations were conducted to investigate whether these gearshift algorithms could be simplified and, in particular, whether engine shift speeds could be replaced by vehicle shift speeds. The analysis showed that vehicle speeds could not be brought in line with the gearshift behaviour of the in-use data. 4.3.1. Table Ap9-2 Input data for the calculation of engine and vehicle shift speeds Item | Input data Engine capacity in cm3 | 600 Pn in kW | 72 mk in kg | 199 s in min-1 | 11 800 nidle in min-1 | 1 150 ndv1 (1) | 133,66 ndv2 | 94,91 ndv3 | 76,16 ndv4 | 65,69 ndv5 | 58,85 ndv6 | 54,04 pmr (2) in kW/t | 262,8 (*1) ndv means the ratio between engine speed in min-1 and vehicle speed in km/h (*2) pmr means the power-to-mass ratio calculated by 1. Pn / (mk+75) · 1 000 ; Pn in kW, mk in kg 4.3.2. Table Ap9-3 Shift speeds for acceleration phases for first gear and for highe…
2.6.added
The relative air density, dT, shall be calculated using the following formula: Equation Ap 7-1: where:
3. Condition of the test vehicleadded
3.1. | The test vehicle shall comply with the conditions described in point 1 of Appendix 8. 3.2. | When installing the measuring instruments on the test vehicle, care shall be taken to minimise their effects on the distribution of the load across the wheels. When installing the speed sensor outside the vehicle, care shall be taken to minimise the additional aerodynamic loss. 3.3. | ChecksThe following checks shall be made in accordance with the manufacturer’s specifications for the use considered: wheels, wheel rims, tyres (make, type and pressure), front axle geometry, brake adjustment (elimination of parasitic drag), lubrication of front and rear axles, adjustment of the suspension and vehicle ground clearance, etc. Check that during freewheeling, there is no electrical braking.
1. Scope of the Appendixdeleted
This Appendix applies to the type-approval of separate technical units within the meaning of Article 23(10) of Regulation (EU) No 168/2013, of pollution-control devices to be fitted as replacement parts on one or more types of L-category vehicle.
2. Definitionsdeleted
2.1. ‘original equipment pollution-control devices’ mean pollution-control devices including oxygen sensors, catalytic converter types, assemblies of catalytic converters, particulate filters or carbon canisters for evaporative emission control covered by the type-approval and originally delivered for the approved vehicle; 2.2. ‘replacement pollution-control devices’ means pollution-control devices including oxygen sensors, catalytic converter types, assemblies of catalytic converters, particulate filters or carbon canisters for evaporative emission control intended to replace an original equipment pollution-control device on a vehicle type with regard to environmental and propulsion unit performance approved in accordance with this Appendix and which can be type-approved as a separate technical unit in accordance with Regulation (EU) No 168/2013;
4.1.added
The coast-down times must be measured between v1 and v2 as specified in Table Ap 7-1, depending on the vehicle class as defined in point 4.3. of Annex II.
3. Application for environmental performance ty…deleted
3.1. Applications for type-approval of a type of replacement pollution-control device as a separate technical unit shall be submitted by the manufacturer of the system or by his authorised representative. 3.2. A model for the information document is referred to in Article 27(4) of Regulation (EU) No 168/2013. 3.3. For each type of replacement pollution-control device for which approval is requested, the type-approval application shall be accompanied by the following documents in triplicate, and by the following particulars: 3.3.1. A description of the types of vehicles for which the device is intended, in terms of its characteristics; 3.3.2. The numbers or symbols specific to the propulsion and vehicle type; 3.3.3. Description of the replacement catalytic converter type stating the relative position of each of its components, together with the fitting instructions; 3.3.4. Drawings of each component to facilitate location and identification, and statement of materials used. These drawings shall also indicate the intended location of the mandatory type-approval mark. 3.4. The following shall be submitted to the technical service responsible for the type-approval test: 3.4.1. Vehicle(s) of a type approved in accordance with this Appendix equipped with a new original equipment pollution-control device type. This (these) vehicles shall be selected by the applicant with the agreement of the technical service to the satisfaction of the approval authority. It (they) shall comply wit…
4.2.added
Table Ap7-1 Coast-down time measurement beginning speed and ending speed Maximum design speed (km/h) | Specified target vehicle speed vj in (km/h) | v1 in (km/h) | v2 in (km/h) ≤ 25 km/h 20 | 25 | 15 15 | 20 | 10 10 | 15 | 5 ≤ 45 km/h 40 | 45 | 35 30 | 35 | 25 20 | 25 | 15 45 < maximum design speed ≤ 130 km/h and > 130 km/h 120 | 130*/ | 110 100 | 110*/ | 90 80 | 90*/ | 70 60 | 70 | 50 40 | 45 | 35 20 | 25 | 15
4.3.added
When the running resistance is verified in accordance with point 5.2.2.3.2., the test can be executed at vj ± 5 km/h, provided that the coast-down time accuracy referred to in point 4.5.7. of Annex II is ensured.
4.1. General requirementsdeleted
The design, construction and mounting of the replacement pollution-control device type shall be such that: 4.1.1. the vehicle complies with the requirements of this Regulation under normal conditions of use, and in particular regardless of any vibrations to which it may be subjected; 4.1.2. the replacement pollution-control device displays reasonable resistance to the corrosion phenomena to which it is exposed, with due regard to the normal conditions of use of the vehicle; 4.1.3. the ground clearance available with the original equipment pollution-control device type and the angle at which the vehicle can lean over are not reduced; 4.1.4. the surface of the device does not reach unduly high temperatures; 4.1.5. the outline of the device has no projections or sharp edges; 4.1.6. shock absorbers and suspension have adequate clearance; 4.1.7. adequate safety clearance is provided for pipes; 4.1.8. the replacement pollution-control device is impact-resistant in a way that is compatible with clearly-defined maintenance and installation requirements; 4.1.9. if the original equipment pollution-control includes thermal protection, the replacement pollution-control device shall include equivalent protection; 4.1.10. if (an) oxygen probe(s) and other sensors or actuators are originally installed on the exhaust line, the replacement pollution-control device type shall be installed at exactly the same position as the original equipment pollution-control device and the position on the e…
4.2. Requirements regarding emissionsdeleted
4.2.1. The vehicle referred to in point 3.4.1, equipped with a replacement pollution-control device of the type for which type-approval is requested, shall undergo the tests laid down in Annexes II and VI (depending on the type-approval of the vehicle) ( 6 ). 4.2.1.1. Evaluation of pollutant emissions from vehicles equipped with replacement pollution-control devices Requirements regarding tailpipe or evaporative emissions are deemed to be complied with if the test vehicle equipped with the replacement pollutant-control device complies with the limit values in Annex VI to Regulation (EU) No 168/2013 (according to the type-approval of the vehicle) (6) . 4.2.1.2. Where the type-approval application is for different types of vehicles from the same manufacturer, the type I test may be limited to as few as two vehicles selected after agreement with the technical service to the satisfaction of the approval authority, provided that the different types of vehicle are fitted with the same type of original equipment pollution-control device. 4.2.2. Requirements regarding permissible sound level The vehicles referred to in point 3.4.1, equipped with a replacement pollution-control device type that could allow worse noise emissions than the type for which type-approval is requested, shall satisfy the requirements of Annex IX (according to the type-approval of the vehicle) (6) . The test result for the vehicle in motion and for the stationary test shall be mentioned in the test report.
5.1.added
After a warm-up period, the vehicle shall be accelerated to the coast-down starting speed, at which point the coast-down measurement procedure shall be started.
4.3. Testing of the propulsion performance of the…deleted
4.3.1. The replacement pollution-control device type shall be such as to ensure that the propulsion performance of the vehicle is comparable with that achieved with the original equipment pollution-control device type. 4.3.2. The propulsion performance of the vehicle equipped with the replacement pollution-control device shall be compared with that of an original equipment pollution-control device, also in new condition, fitted in turn to the vehicle referred to in point 3.4.1. 4.3.3. This test is carried out according to the applicable procedure set out in Annex X. The maximum net power and torque as well as the maximum attainable vehicle speed, if applicable, measured with the replacement pollution-control device, shall not deviate by more than + 5 % from those measured under the same conditions with the type-approved original equipment pollution-control device type.
5.2.added
Since shifting the transmission to neutral can be dangerous and complicated by the construction of the vehicle, the coasting may be performed solely with the clutch disengaged. Vehicles that have no means of cutting the transmitted engine power off prior to coasting may be towed until they reach the coast-down starting speed. When the coast-down test is reproduced on the chassis dynamometer, the drive train and clutch shall be in the same condition as during the road test.
5.3.added
The vehicle steering shall be altered as little as possible and the brakes shall not be operated until the end of the coast-down measurement period.
1. Introductiondeleted
1.1. This Appendix defines the specific provisions regarding type-approval of hybrid electric L-category vehicles (HEV). 1.2. In principle, for the environmental type I to IX tests, hybrid electric vehicles shall be tested in accordance with this Regulation, unless otherwise provided for in this Appendix. 1.3. For the type I and type VII tests, off-vehicle charging (OVC) vehicles (as categorised in point 2) shall be tested according to Conditions A and B. Both sets of test results and the weighted values shall be reported in the test report drafted in accordance with the template referred to in Article 32(1) of Regulation (EU) No 168/2013. 1.4. The emissions test results shall comply with the limits set-out in Regulation (EU) No 168/2013 under all test conditions specified in this Regulation.
5.4.added
The first coast-down time Δtai corresponding to the specified speed vj shall be measured as the time taken for the vehicle to decelerate from vj + Δv to vj – Δv.
2. Categories of hybrid vehiclesdeleted
Table Ap11-1 Hybrid vehicle categories Vehicle charging | Off-Vehicle Charging (1) (OVC) | Not-off-vehicle Charging (2) (NOVC) Operating mode switch | Without | With | Without | With (1) Also known as ‘externally chargeable’. (2) Also known as ‘not externally chargeable’.
5.5.added
The procedure described in points 5.1. to 5.4. shall be repeated in the opposite direction to measure the second coast-down time Δtbi.
3. Type I test methodsdeleted
For the type I test, hybrid electric L-category vehicles shall be tested according to the applicable procedure in Annex VI to Regulation (EU) No 168/2013. For each test condition, the pollutant emission test result shall comply with the limits in Parts A1 and A2 of Annex VI to Regulation (EU) No 168/2013, whichever is applicable in accordance with Annex IV to Regulation (EU) No 168/2013.
5.6.added
The average Δti of the two coast-down times Δtai and vtbi shall be calculated using the following equation: Equation Ap 7-2:
3.1. Externally chargeable vehicles (OVC HEVs) wi…deleted
3.1.1. | Two tests shall be performed under the following conditions: (a) condition A: the test shall be carried out with a fully charged electrical energy/power storage device. (b) condition B: the test shall be carried out with an electrical energy/power storage device in minimum state of charge (maximum discharge of capacity). The profile of the state of charge (SOC) of the electrical energy/power storage device during different stages of the test is given in Appendix 3.1. to Annex VII. 3.1.2. | Condition A 3.1.2.1. The procedure shall start with the discharge of the electrical energy/power storage device of the vehicle while driving (on the test track, on a chassis dynamometer, etc.) in any of the following conditions: (a) at a steady speed of 50 km/h until the fuel-consuming engine starts up; (b) if a vehicle cannot reach a steady speed of 50 km/h without the fuel-consuming engine starting up, the speed shall be reduced until it can run at a lower steady speed at which the fuel-consuming engine does not start up for a defined time or distance (to be determined by the technical service and the manufacturer subject to the agreement of the approval authority); (c) in accordance with the manufacturer’s recommendation. The fuel-consuming engine shall be stopped within ten seconds of being automatically started. 3.1.2.2. Conditioning of vehicleThe vehicle shall be conditioned by driving the applicable type I driving…
5.7.added
At least four tests shall be performed and the average coast-down time ΔTj calculated using the following equation: Equation Ap 7-3:
5.8.added
Tests shall be performed until the statistical accuracy P is equal to or less than 3 percent (P ≤ 3 percent). The statistical accuracy P (as a percentage) is calculated using the following equation: Table Ap7-2 Coefficients for statistical accuracy n | t 4 | 3,2 | 1,60 5 | 2,8 | 1,25 6 | 2,6 | 1,06 7 | 2,5 | 0,94 8 | 2,4 | 0,85 9 | 2,3 | 0,77 10 | 2,3 | 0,73 11 | 2,2 | 0,66 12 | 2,2 | 0,64 13 | 2,2 | 0,61 14 | 2,2 | 0,59 15 | 2,2 | 0,57
1. Introductiondeleted
1.1. This Appendix describes the special requirements as regards the testing of LPG, NG/biomethane, H2NG or hydrogen gas for the approval of alternative fuel vehicles that run on those fuels or can run on petrol, LPG, NG/biomethane, H2NG or hydrogen. 1.2. The composition of these gaseous fuels, as sold on the market, can vary greatly and fuelling systems must adapt their fuelling rates accordingly. To demonstrate this adaptability, the parent vehicle equipped with a representative LPG, NG/biomethane or H2NG fuel system shall be tested in type I tests on two extreme reference fuels. 1.3. The requirements of this Appendix as regards hydrogen shall apply only to vehicles using hydrogen as a combustion fuel and not to those equipped with a fuel cell operating on hydrogen.
5.9.added
In repeating the test, care shall be taken to start the coast-down after observing the same warm-up procedure and at the same coast-down starting speed.
2. Granting of type-approval for an L-category …deleted
Type-approval is granted subject to the following requirements:
5.10.added
The coast-down times for multiple specified speeds may be measured in a continuous coast-down. In this case, the coast-down shall be repeated after observing the same warm-up procedure and at the same coast-down starting speed.
2.1. Exhaust emissions approval of a vehicle equi…deleted
It shall be demonstrated that the parent vehicle equipped with a representative LPG, NG/biomethane, H2NG or hydrogen fuel system can adapt to any fuel composition that may appear on the market and comply with the following: 2.1.1. In the case of LPG there are variations in C3/C4 composition (test fuel requirement A and B) and therefore the parent vehicle shall be tested on reference fuels A and B referred to in Appendix 2; 2.1.2. In the case of NG/biomethane there are generally two types of fuel, high calorific fuel (G20) and low calorific fuel (G25), but with a significant spread within both ranges; they differ significantly in Wobbe index. These variations are reflected in the reference fuels. The parent vehicle shall be tested on both reference fuels referred to in Appendix 2; 2.1.3. In the case of a flex fuel H2NG vehicle, the composition range may vary from 0 % hydrogen (L-gas) to a maximum percentage of hydrogen within the mixture (H-gas), as specified by the manufacturer. It shall be demonstrated that the parent vehicle can adapt to any percentage within the range specified by the manufacturer and the vehicle shall be tested in the type I test on 100 % H-gas and 100 % L-gas. It shall also be demonstrated that it can adapt to any NG/biomethane composition that may appear on the market, regardless of the percentage of hydrogen in the mixture. 2.1.4. For vehicles equipped with hydrogen fuel systems, compliance shall be tested on the single hydrogen reference fuel referre…
5.11.added
The coast-down time shall be recorded. A specimen record form is given in the Regulation for administrative requirements.
2.2. Exhaust emissions approval of a member of th…deleted
For the type-approval of mono-fuel gas vehicles and bi-fuel vehicles operating in gas mode, fuelled by LPG, NG/biomethane, H2NG or hydrogen, as a member of the propulsion family in Annex XI, a type I test shall be performed with one gaseous reference fuel. For LPG, NG/biomethane and H2NG vehicles, this reference fuel may be either of the reference fuels in Appendix 2. The gas-fuelled vehicle is considered to comply if the following requirements are met: 2.2.1. The test vehicle shall comply with the definition of a propulsion family member in Annex XI. 2.2.2. If the test fuel requirement is reference fuel A for LPG or G20 for NG/biomethane, the emission result shall be multiplied by the relevant factor ‘r’ if r > 1; if r < 1, no correction is needed. 2.2.3. If the test fuel requirement is reference fuel B for LPG or G25 for NG/biomethane, the emission result shall be divided by the relevant factor ‘r’ if r < 1; if r > 1, no correction is needed. 2.2.4. At the manufacturer’s request, the type I test may be performed on both reference fuels, so that no correction is needed. 2.2.5. The parent vehicle shall comply with the emission limits for the relevant category set out in Annex VI(A) to Regulation (EU) No 168/2013 and for both measured and calculated emissions. 2.2.6. If repeated tests are conducted on the same engine, an average shall first be taken of the results on reference fuel G20, or A, and those on reference fuel G25, or B; the ‘r’ factor shall then be calculated from …
1. Introductiondeleted
This Appendix contains specific provisions regarding the type-approval of vehicles equipped with a periodically regenerating system.
6.1.1.added
The running resistance force Fj, in Newton, at the specified speed vj shall be calculated using the following equation: Equation Ap7-6: where: mref = reference mass (kg); Δv = vehicle speed deviation (km/h); Δt = calculated coast down time difference (s);
2. Scope of the type-approval for vehicles with…deleted
2.1. | L-category vehicles falling within the scope of Regulation (EU) No 168/2013 that are equipped with periodically regenerating systems shall comply with the requirements in this Appendix. 2.2. | Instead of carrying out the test procedures in the following point, a fixed Ki value of 1,05 may be used if the technical service sees no reason why this value could be exceeded and after approval of the approval authority. 2.3. | During cycles where regeneration occurs, emission standards can be exceeded. If a regeneration of an anti-pollution device occurs at least once per Type I test and that has already regenerated at least once during the vehicle preparation cycle, it will be considered as a continuously regenerating system which does not require a special test procedure.
6.1.2.added
The running resistance force Fj shall be corrected in accordance with point 6.2.
3. Test proceduredeleted
The vehicle may be equipped with a switch capable of preventing or permitting the regeneration process provided that its operation has no effect on original engine calibration. This switch shall be used for the purpose of preventing regeneration only during loading of the regeneration system and during the pre-conditioning cycles. However, it shall not be used during the measurement of emissions in the regeneration phase; rather, the emission test shall be carried out with the unchanged original equipment manufacturer’s powertrain control unit / engine control unit / drive train control unit if applicable and powertrain software. 3.1. | Measurement of carbon dioxide emission and fuel consumption between two cycles where regenerative phases occur. 3.1.1. The average of carbon dioxide emission and fuel consumption between regeneration phases and during loading of the regenerative device shall be determined from the arithmetic mean of several approximately equidistant (if more than two) type I operating cycles. As an alternative, the manufacturer may provide data to show that carbon dioxide emissions and fuel consumption remain constant (+4 percent) between regeneration phases. In this case, the carbon dioxide emissions and fuel consumption measured during the regular type I test may be used. In any other case, emissions shall be measured for at least two type I operating cycles: one immediately after regeneration (before new loading) and one as immediately as …
6.2. Running resistance curve fittingadded
The running resistance force, F, shall be calculated as follows:
6.2.1.added
The following equation shall be fitted to the data set of Fj and vj obtained in points 4 and 6.1. respectively by linear regression to determine the coefficients f0 and f2, Equation Ap7-7:
6.2.2.added
The coefficients f0 and f2 thus determined shall be corrected to the standard ambient conditions using the following equations:
6.3. Target running resistance force F* for chass…added
The target running resistance force F*(v0) on the chassis dynamometer at the reference vehicle speed v0, in Newton, is determined using the following equation: Equation Ap7-10:
4.1 Components for adjusting the idling speeddeleted
4.1.1. Components for adjusting the idling speed for the purposes of this Annex refer to controls for changing the idling conditions of the engine which may be easily operated by a mechanic using only the tools referred to in point 4.1.2. In particular, devices for calibrating fuel and air flows are not considered as adjustment components if their setting requires the removal of the set-stops, an operation which can normally be performed only by a professional mechanic. 4.1.2. The tools which may be used to adjust the idling speed are screwdrivers (ordinary or cross-headed), spanners (ring, open-end or adjustable), pliers, Allen keys and a generic scan tool.
4.2 Determination of measurement points and type …deleted
4.2.1. First, a measurement is taken at the setting in accordance with the conditions fixed by the manufacturer. 4.2.2. For each adjustment component with a continuous variation, a sufficient number of characteristic positions shall be determined. The test shall be carried out with the engine at normal idling speed and at ‘high idle’ speed. High idle engine speed is defined by the manufacturer but it must be higher than 2 000 min–1. 4.2.3. The measurement of the carbon monoxide content of exhaust gases shall be carried out for all the possible positions of the adjustment components, but for components with a continuous variation only for the positions referred to in point 4.2.2. 4.2.4. The type II idle test shall be considered passed if one or both of the following conditions is met: 4.2.4.1. the values measured in accordance with point 4.2.3. shall be in compliance with the requirements set out in points 8.2.1.2. of Annex II to Directive 2009/40/EC; 4.2.4.1.1. if point 8.2.1.2. (a) is selected by the manufacturer, the specific CO level given by the manufacturer shall be entered on the certificate of conformity; 4.2.4.1.2. If point 8.2.1.2. (b) (ii) is selected by the manufacturer, the highest CO limits (at engine idle: 0,5 %, at high idle: 0,3 %) shall apply. Footnote (6) to point 8.2.1.2. (b) (ii) shall not be applicable for vehicles in the scope of Regulation (EU) No 168/2013. The measured CO value in the Type II test procedure shall be entered on the certificate of confo…
1.1. Running-inadded
The test vehicle shall be in normal running order and adjustment after having been run in for at least 300 km. The tyres shall be run in at the same time as the vehicle or shall have a tread depth within 90 and 50 percent of the initial tread depth.
1.2. Checksadded
The following checks shall be made in accordance with the manufacturer’s specifications for the use considered: wheels, wheel rims, tyres (make, type and pressure), front axle geometry, brake adjustment (elimination of parasitic drag), lubrication of front and rear axles, adjustment of the suspension and vehicle ground clearance, etc. Check that during freewheeling, there is no electrical braking.
1.3.1.added
The test vehicle shall be loaded to its test mass including driver and measurement equipment, spread in a uniform way in the loading areas.
1.3.2.added
The windows of the vehicle shall be closed. Any covers for air conditioning systems, headlamps, etc. shall be closed.
1.3.3.added
The test vehicle shall be clean, properly maintained and used.
1.3.4.added
Immediately before the test, the vehicle shall be brought to the normal running temperature in an appropriate manner.
1.3.5.added
When installing the measuring instruments on the test vehicle, care shall be taken to minimise their effects on the distribution of the load across the wheels. When installing the speed sensor outside the test vehicle, care shall be taken to minimise the additional aerodynamic loss.
2. Specified vehicle speed vadded
The specified speed is required for determining the running resistance at the reference speed from the running resistance curve. To determine the running resistance as a function of vehicle speed in the vicinity of the reference speed v0, running resistances shall be measured at the specified speed v. At least four to five points indicating the specified speeds, along with the reference speeds, shall be measured. The calibration of the load indicator referred to in point 2.2. of Appendix 3 shall be performed at the applicable reference vehicle speed (vj) referred to in Table Ap8-1. Table Ap8-1 Specified vehicle speeds to perform the coast-down time test as well as the designated reference vehicle speed vj depending on the maximum design speed (vmax) of the vehicle Category vmax | Vehicle speed (km/h) > 130 | 120 (*2) | 100 | 80 (*1) | 60 | 40 | 20 130-100 | 90 | 80 (*1) | 60 | 40 | 20 | — 100-70 | 60 | 50 (*1) | 40 | 30 | 20 | — 70-45 | 50 (*2) | 40 (*1) | 30 | 20 | — | — 45-25 | 40 | 30 (*1) | 20 ≤ 25 km/h | 20 | 15 (*1) | 10 (*1) Applicable reference vehicle speed vj (*2) if the vehicle speed can be attained by the vehicle.
2. General provisionsdeleted
2.1. The manufacturer shall provide the approval authority with technical details and drawings to prove that the engine is or engines are so constructed as to prevent any fuel, lubrication oil or crankcase gases from escaping to the atmosphere from the crankcase gas ventilation system. 2.2. Only in the following cases shall the technical service and approval authority require the manufacturer to carry out the type III test: 2.2.1. for new vehicle types with regard to environmental performance equipped with a new design of the crankcase gas ventilation system, in which case a parent vehicle, with a crankcase gas ventilation concept representative of that approved, may be selected if the manufacturer so chooses to demonstrate to the satisfaction of the technical service and approval authority that the type III test has been passed; 2.2.2. if there is any doubt that any fuel, lubrication oil or crankcase gases might escape to the atmosphere from the crankcase gas ventilation system, the technical service and the approval authority may require the manufacturer to conduct the type III test in accordance with point 4.1 or 4.2 (as chosen by the manufacturer). 2.3. In all other cases, the type III test shall be waived. 2.4. L-category vehicles equipped with a two-stroke engine containing a scavenging port between the crank case and the cylinder(s) may be exempted from the type III test requirements at the request of the manufacturer. 2.5. The manufacturer shall attach a copy of the …
3. Test conditionsdeleted
3.1. The type III test shall be carried out on a test vehicle which has been subjected to the type I testing in Annex II and the type II testing in Annex III. 3.2. The vehicle tested shall have a leak-proof engine or leak-proof engines of a type other than those so designed that even a slight leak may cause unacceptable operating faults. The test vehicle shall be properly maintained and used.
4. Test methodsdeleted
4.1. | The type III test shall be conducted according to the following test procedure: 4.1.1. Idling shall be regulated in conformity with the manufacturer’s recommendations. 4.1.2. Measurements shall be taken in the following sets of conditions of engine operation: Table 3-1 Idle operation or steady state vehicle test speeds and power absorbed by the chassis dynamometer during the type III test Condition number Vehicle speed (km/h) 1 Idling 2 Highest of: (a) 50 ±2 (in 3rd gear or ‘drive’) or (b) if (a) not achievable, 50 % of max. design vehicle speed. 3 Condition number Power absorbed by the brake 1 Nil 2 That corresponding to the setting for type I test at 50 km/h or if not achievable type I test at 50 % of max. design vehicle speed. 3 As for condition 2, multiplied by a factor of 1,7 4.1.3. For all operation conditions listed in point 4.1.2., the reliable functioning of the crankcase ventilation system shall be checked. 4.1.4. Method of verification of the crankcase ventilation system 4.1.4.1. The engine’s apertures shall be left as found. 4.1.4.2. The pressure in the crankcase shall be measured at an appropriate location. It may be measured at the dip-stick hole with an inclined-tube manometer. 4.1.4.3. The v…
3.1.1. Measurement equipment and accuracyadded
The margin of measurement error shall be less than 0,1 second for time and less than ± 0,5 km/h for speed. Bring the vehicle and the chassis dynamometer to the stabilised operating temperature, in order to approximate the road conditions.
ANNEX Vdeleted
Appendix Number | Appendix title 1 | Fuel storage permeability test procedure 2 | Fuel storage and delivery system permeation test procedure 3 | Sealed Housing for Evaporation Determination (SHED) test procedure 3.1. | Preconditioning requirements for a hybrid application before start of the SHED test 3.2. | Ageing test procedure for evaporative emission control devices 4 | Calibration of equipment for evaporative emission testing
3.1.2. Test procedureadded
3.1.2.1. | Accelerate the vehicle to a speed of 5 km/h greater than the speed at which test measurement begins. 3.1.2.2. | Put the gearbox to neutral or disconnect the power supply. 3.1.2.3. | Measure the time t1 taken by the vehicle to decelerate from: to where: Δv < 5 km/h for nominal vehicle speed < 50 km/h; Δv < 10 km/h for nominal vehicle speed > 50 km/h. 3.1.2.4. | Carry out the same test in the opposite direction, measuring time t2. 3.1.2.5. | Take the average ti of the two times t1 and t2. 3.1.2.6. | Repeat these tests until the statistical accuracy (p) of the average: Equation Ap 8-1: The statistical accuracy (p) is defined by: Equation Ap 8-2: is no more than 4 percent (p ≤ 4 percent).where: t is the coefficient in Table Ap 8-2; s is the standard deviation. Equation Ap 8-3: n is the number of tests Table Ap8-2 Factors t and t/√n depending on the number of coast-down tests performed n 4 5 6 7 8 9 10 t 3,2 2,8 2,6 2,5 2,4 2,3 2,3 t/√n 1,6 1,25 1,06 0,94 0,85 0,77 0,73 n | 4 | 5 | 6 | 7 | 8 | 9 | 10 t | 3,2 | 2,8 | 2,6 | 2,5 | 2,4 | 2,3 | 2,3 t/√n | 1,6 | 1,25 | 1,06 | 0,94 | 0,85 | 0,77 | 0,73 3.1.2.7. | Calculation of the running resistance forceThe running resistance force F at the specified vehicle speeds v is calculated as fol…
1. Introductiondeleted
1.1. This Annex describes the procedure for type IV testing, as referred to in Part A of Annex V to Regulation (EU) No 168/2013. 1.2. Appendix 1 describes the procedure for testing the permeability of non-metallic fuel tank material and shall also be used as preconditioning test cycle for fuel storage testing referred to in Number C8 of Annex II to Regulation (EU) No 168/2013. 1.3. Appendices 2 and 3 describe methods for the determination of the loss of hydrocarbons by evaporation from the fuel systems of vehicles equipped with a propulsion type that uses volatile, liquid fuel. Appendix 4 sets out the calibration procedure for evaporative emission test equipment.
3.2. Setting of the chassis dynamometeradded
The purpose of this procedure is to simulate on the dynamometer the total road load power at a given speed.
2. General requirementsdeleted
2.1. The vehicle manufacturer shall prove to the technical service and to the satisfaction of the approval authority that the fuel tank and fuelling system are leak-tight. 2.2. The fuelling system tightness shall comply with the requirements referred to in Annex II (C8) to Regulation (EU) No 168/2013. 2.3. All L-vehicle (sub-)categories equipped with a non-metallic fuel storage shall be tested according to the permeability test procedure laid down in Appendix 1. At the request of the manufacturer, the fuel permeation test set out in Appendix 2 or the SHED test set out in Appendix 3 may replace the evaporative part of the permeability test set out in Appendix 1. 2.4. L-vehicle (sub-)categories L3e, L4e, L5e-A, L6e-A and L7e-A shall be tested according to the SHED test procedure laid down in Appendix 3. 2.5. The fuel permeation test procedure set out in Appendix 2 shall be subject to the general assessment in the environmental effect study referred to in point 5(b) of Article 23 of Regulation (EU) No 168/2013. This study shall confirm whether L-vehicle (sub-)categories L1e-A, L1e-B, L2e, L5e-B, L6e-B, L7e-B and L7e-C shall be tested either according to the permeation test procedure set out in Appendix 2 or the SHED test procedure set out in Appendix 3. 2.6. If an L1e-A, L1e-B, L2e, L5e-B, L6e-B, L7e-B and L7e-C vehicle is to be subject to a SHED test procedure set out in Part C of Annex VI to Regulation (EU) No 168/2013 and in Appendix 3, it shall be exempted from the fuel per…
3.2.1. Measurement equipment and accuracyadded
The measuring equipment shall be similar to that used on the test track and shall comply with point 4.5.7. of Annex II and point 1.3.5 of this Appendix.
1. Scopedeleted
1.1. | This requirement shall apply to all L-category vehicles equipped with a non-metallic fuel tank to store liquid, volatile fuel, as applicable for vehicles equipped with a positive ignition combustion engine. 1.2. | Vehicles complying with the requirements set out in Appendix 2 or 3 or vehicles equipped with a compression ignition engine using low volatile fuel shall comply with the requirements of this Appendix only as preconditioning procedure for fuel storage testing referred to in Number C8 of Annex II to Regulation (EU) No 168/2013. The fuel tanks on those vehicles are exempted from the evaporative requirements set out in points 2.1.5, 2.1.6, 2.3. and 2.4.
3.2.2.1.added
Install the vehicle on the chassis dynamometer.
3.2.2.2.added
Adjust the tyre pressure (cold) of the driving wheels as required for the chassis dynamometer.
3.2.2.3.added
Adjust the equivalent inertia mass of the chassis dynamometer, in accordance with Table Ap8-4. Table Ap8-4 Determination of equivalent inertia mass for an L-category vehicle equipped with two or more wheels on the powered axles Reference mass (mref) (kg) | Equivalent inertia mass (mi) (kg) mref ≤ 105 | 100 105 < mref ≤ 115 | 110 115 < mref ≤ 125 | 120 125 < mref ≤ 135 | 130 135 < mref ≤ 150 | 140 150 < mref ≤ 165 | 150 165 < mref ≤ 185 | 170 185 < mref ≤ 205 | 190 205 < mref ≤ 225 | 210 225 < mref ≤ 245 | 230 245 < mref ≤ 270 | 260 270 < mref ≤ 300 | 280 300 < mref ≤ 330 | 310 330 < mref ≤ 360 | 340 360 < mref ≤ 395 | 380 395 < mref ≤ 435 | 410 435 < mref ≤ 480 | 450 480 < mref ≤ 540 | 510 540 < mref ≤ 600 | 570 600 < mref ≤ 650 | 620 650 < mref ≤ 710 | 680 710 < mref ≤ 770 | 740 770 < mref ≤ 820 | 800 820 < mref ≤ 880 | 850 880 < mref ≤ 940 | 910 940 < mref ≤ 990 | 960 990 < mref ≤ 1 050 | 1 020 1 050 < mref ≤ 1 110 | 1 080 1 110 < mref ≤ 1 160 | 1 130 1 160 < mref ≤ 1 220 | 1 190 1 220 < mref ≤ 1 280 | 1 250 1 280 < mref ≤ 1 330 | 1 300 1 330 < mref ≤ 1 390 | 1 360 1 390 < mref ≤ 1 450 | 1 420 1 450 < mref ≤ 1 500 | 1 470 1 500 < mref ≤ 1 560 | 1 530 1 560 < mref ≤ 1 620 | 1 590 1 620 < mref ≤ 1 670 | 1 640 1 670 < mref ≤ 1 730 | 1 700 1 730 < mref ≤ 1 790 | 1 760 1 790 < mref ≤ 1 870 | 1 810 1 870 < mref ≤ 1 980 | 1 930 1 980 < mref ≤ 2 100 | 2 040 2 100 < mref ≤ 2 210 | 2 150 2 210 < mref ≤ 2 320 | 2 270 2 320 < mref ≤ 2 440 | 2 380 2 440 < RM | 2 490
2.1.1. Test temperaturedeleted
The fuel tank shall be tested at a temperature of 313,2 ± 2 K (40 ± 2 °C).
3.2.2.4.added
Bring the vehicle and the chassis dynamometer to the stabilised operating temperature, in order to approximate the road conditions.
2.1.2. Test fueldeleted
The test fuel to be used shall be the reference fuel set out in Appendix 2 of Annex II. If this test procedure is used only as preconditioning for subsequent fuel storage testing referred to in Number C8 of Annex II to Regulation (EU) No 168/2013, a commercial premium-grade fuel may be used at the choice of the manufacturer and to the satisfaction of the approval authority. 2.1.3. | The tank is filled with the test fuel up to 50 % of its total rated capacity and allowed to rest in the ambient air at a temperature of 313,2 ± 2 K until there is a constant weight loss. That period shall be at least four weeks (pre-storage period). The tank is emptied and then refilled with test fuel to 50 % of its rated capacity. 2.1.4. | The tank is stored under the stabilising conditions at a temperature of 313,2 ± 2 K until its contents are at the test temperature. The tank is then sealed. The pressure rise in the tank during the test may be compensated. 2.1.5. | The weight loss due to diffusion shall be measured during the eight-week test. During that period, a maximum quantity of 20 000 mg may escape from the fuel tank, on average, every 24 hours. 2.1.6. | If the diffusion losses are greater, the fuel loss shall also be determined at a test temperature of 296,2 ± 2 K (23 ± 2 °C), all other conditions being maintained (pre-storage at 313,2 ± 2 K). The loss determined under those conditions shall not exceed 10 000 mg per 24 hours. 2.2. | All fuel tanks that will undergo this test procedure a…
3.2.2.5.added
Carry out the operations specified in point 3.1.2., with the exception of those in points 3.1.2.4. and 3.1.2.5.
3.2.2.6.added
Adjust the brake to reproduce the corrected running resistance (see point 3.1.2.8.) and to take into account the reference mass. This may be done by calculating the mean corrected road coast-down time from v1 to v2 and reproducing the same time on the dynamometer as follows: Equation Ap 8-8:
1 Scope and test limitsdeleted
1.1. | As of the date of first application laid down in Annex IV to Regulation (EU) No 168/2013, fuel system permeation shall be tested in accordance with the test procedure laid down in point 2. This base requirement shall apply to all L-category vehicles equipped with a fuel tank to store liquid, high volatile fuel, as applicable for a vehicle equipped with a positive ignition combustion engine, in accordance with Part B of Annex V to Regulation (EU) No 168/2013 and pending the results of the environmental effect study laid down in Article 23 of Regulation (EU) No 168/2013. ▼M1 In order to satisfy the evaporative emission test requirements set out in Regulation (EU) No 168/2013, only L-vehicle (sub-)categories L3e, L4e, L5e-A, L6e-A and L7e-A shall be tested. ▼B 1.2. | For the purposes of the requirements of this Appendix, the minimum fuel system components falling within the scope of this Appendix consist of a fuel storage tank and fuel line sub-assembly. Other components that form part of the fuel delivery system, fuel metering and control system are not subject to the requirements of this Appendix.
3.2.2.7.added
The power Pa to be absorbed by the bench shall be determined in order to enable the same total road load power to be reproduced for the same vehicle on different days or on different chassis dynamometers of the same type.
0. Introductionadded
This explanatory note explains matters specified or described in this Regulation, including its Annexes or Appendices, and matters related thereto with regard to the gearshift procedure.
Fuel tank permeation full and short testsdeleted
2.2. | Metallic tanks are exempted from durability testing.
3. Preconditioning fuel soak for the fuel tank …deleted
To precondition the fuel tank in the fuel tank permeation test, the following five steps shall be followed: 3.1. | The tank shall be filled with reference fuel specified in Appendix 2 to Annex II, and sealed. The filled tank shall be soaked at an ambient temperature of 301,2 ± 5 K (28 ± 5 °C) for 20 weeks or at 316,2 ± 5 K (43 ± 5 °C) for ten weeks. Alternatively, a shorter period of time at a higher -temperature may be used as soak time if the manufacturer can prove to the approval authority that the hydrocarbon permeation rate has stabilised. 3.2. | The fuel tank’s internal surface area shall be determined in square metres accurate to at least three significant figures. The manufacturer may use less accurate estimates of the surface area if it is ensured that the surface area will not be overestimated. 3.3. | The fuel tank shall be filled with the reference fuel to its nominal capacity. 3.4. | The tank and fuel shall equilibrate to 301,2 ± 5 K (28 ± 5 °C) or 316,2 ± 5 K (43 ± 5 °C) in the case of the alternative short test. 3.5. | The fuel tank shall be sealed using fuel caps and other fittings (excluding petcocks) that can be used to seal openings in a production fuel tank. In cases where openings are not normally sealed on the fuel tank (such as hose-connection fittings and vents in fuel caps), these openings may be sealed using non-permeable fittings such as metal or fluoropolymer plugs.
1.1.added
The development of the gearshift procedure was based on an analysis of the gearshift points in the in-use data. In order to establish generalised correlations between technical specifications of the vehicles and gearshift speeds, the engine speeds were normalised to the utilisable band between rated speed and idling speed.
4. Fuel tank permeation test proceduredeleted
To run the test, the following steps shall be taken for a tank preconditioned as specified in point 3. 4.1. | Weigh the sealed fuel tank and record the weight in mg. This measurement shall be taken within eight hours of filling of the tank with test fuel. 4.2. | The tank shall be placed in a ventilated, temperature-controlled room or enclosure. 4.3. | The test room or enclosure shall be closed and sealed and the test time shall be recorded. 4.4. | The test room or enclosure temperature shall be continuously maintained at ►M1 301,2 ± 5 K (28 ± 5 °C) ◄ for 14 days. This temperature shall be continuously monitored and recorded.
1.2.added
In a second step, the end speeds (vehicle speed as well as normalised engine speed) for upshifts and downshifts were determined and recorded in a separate table. The averages of these speeds for each gear and vehicle were calculated and correlated with the vehicles’ technical specifications.
5. Fuel tank permeation test result calculationdeleted
5.1. | At the end of the soak period, the weight in mg of the sealed fuel tank shall be recorded. Unless the same fuel is used in the preconditioning fuel soak and the permeation test run, weight measurements shall be recorded on five separate days per week of testing. The test is void if a linear plot of tank weight vs. test days for the full soak period for permeation testing yields a linear regression correlation coefficient r2 < 0,8. 5.2. | The weight of the filled fuel tank at the end of the test shall be subtracted from the weight of the filled fuel tank at the beginning of the test. 5.3. | The difference in mass shall be divided by the internal surface area of the fuel tank. 5.4. | The result of the calculation under point 5.3., expressed in mg/m2, shall be divided by the number of test days to calculate the mg/m2/day emission rate and rounded to the same number of decimal places as the emission standard laid down in Part C2 of Annex VI to Regulation (EU) No 168/2013. 5.5. | In cases where permeation rates during a soak period of 14 days are such that the manufacturer considers that period not long enough to be able to measure significant weight changes, the period may be extended by a maximum of 14 additional days. In this case, the test steps in points 4.5 to 4.8 shall be repeated to determine the weight change for the full 28 days. 5.6. | Determination of the deterioration factor when applying the full permeation test procedure The deterioration factor (DF) shall …
1.3.added
The results of these analyses and calculations can be summarised as follows:
6. Fuel tank durability testingdeleted
6.1. | A separate durability demonstration for each substantially different combination of treatment approaches and non-metallic tank materials shall be performed by taking the following steps: 6.1.1. Pressure cycling A pressure test shall be conducted by sealing the tank and cycling it between 115,1 kPa absolute pressure(+ 2,0 psig) and 97,9 kPa absolute pressure (– 0,5 psig) and back to 115,1 kPa absolute pressure(+ 2,0 psig) for 10 000 cycles at a rate of 60 seconds per cycle. 6.1.2. UV exposure A sunlight exposure test shall be conducted by exposing the fuel tank to an ultraviolet light of at least 24 W/m2 (0,40 W-hr/m2/min) on the tank surface for at least 450 hours. Alternatively, the non-metallic fuel tank may be exposed to direct natural sunlight for an equivalent period of time, as long as it is ensured that it is exposed to at least 450 daylight hours. 6.1.3. Slosh testing A slosh test shall be conducted by filling the non-metallic fuel tank to 40 percent of its capacity with the reference fuel set out in Appendix 2 to Annex II or with a commercial premium-grade fuel at the choice of the manufacturer and to the satisfaction of the approval authority. The fuel tank assembly shall be rocked at a rate of 15 cycles per minute until one million total cycles are reached. An angle deviation of + 15° to – 15° from level shall be used and the slosh test shall be conducted at an ambient temperature of 301,2 ± 5 K (28 ± 5 °C). 6.2. | Final fuel tank durability tes…
(a)added
the gearshift behaviour is engine-speed-related rather than vehicle-speed-related;
(b)added
the best correlation between gearshift speeds and technical data was found for normalised engine speeds and the power-to-mass ratio (maximum continuous rated power/(mass in running order + 75 kg));
7.1. Fuel line assembly permeation physical testi…deleted
The manufacturer shall conduct a fuel line assembly test, including the fuel hose clamps and the material to which the fuel lines are connected on both sides, by performing a physical test in accordance with any of the following test procedures:
(c)added
the residual variations cannot be explained by other technical data or by different drive train ratios. They are most probably due to differences in traffic conditions and individual driver behaviour;
(a)deleted
in accordance with the requirements of points 6.2 to 6.4. The piping material to which the fuel lines are connected at both sides of the fuel line shall be plugged with impermeable material. The words ‘fuel tank’ in points 6.2 to 6.4 shall be replaced with ‘fuel-line assembly’. The fuel hose clamps shall be tightened with the torque specified for series production;
(d)added
the best approximation between gearshift speeds and power-to-mass ratio was found for exponential functions;
(b)deleted
the manufacturer may use a proprietary test procedure if it can be demonstrated to the approval authority that this test is just as severe as test method (a).
(e)added
the gearshift mathematical function for the first gear is significantly lower than for all other gears;
7.2. Fuel line assembly permeation test limits in…deleted
The test limits for fuel tubing in Part C2 of Annex VI to Regulation (EU) No 168/2013 shall be met when conducting the test procedures laid down in point 7.1. 7.3. | Physical testing of fuel-line assembly permeation is not required if: (a) the fuel lines meet the R11–A or R12 permeation specifications in SAE J30, or (b) non-metallic fuel lines meet the Category 1 specifications for permeation in SAE J2260, and (c) the manufacturer can demonstrate to the approval authority that the connections between the fuel tank and other fuel system components are leak-tight thanks to robust design. If the fuel hoses fitted on the vehicle meet all three specifications, the fuel tubing test limit requirements in Part C2 of Annex VI to Regulation (EU) No 168/2013 shall be considered as fulfilled.
(f)added
the gearshift speeds for all other gears can be approximated by one common mathematical function;
(g)added
no differences were found between five-speed and six-speed gearboxes;
1. Scopedeleted
1.1. As of the application date laid down in Annex IV to Regulation (EU) No 168/2013, the evaporative emissions of sub-category L3e, L4e (only the base, original L3e vehicle of the motorcycle with side-car), L5e-A, L6e-A and L7e-A vehicles shall be tested in the environmental performance type-approval procedure according to the following SHED test procedure.
(h)added
gearshift behaviour in Japan is significantly different from the equal-type gearshift behaviour in the European Union (EU) and in the United States of America (USA).
2. Description of SHED testdeleted
The evaporative emission SHED test (Figure Ap3-1) consists of a conditioning phase and a test phase, as follows:
1.4.added
In order to find a balanced compromise between the three regions, a new approximation function for normalised upshift speeds versus power-to-mass ratio was calculated as a weighted average of the EU/USA curve (with 2/3 weighting) and the Japanese curve (with 1/3 weighting), resulting in the following equations for normalised engine upshift speeds:
(a)deleted
conditioning phase:
2. Calculation exampleadded
2.1 | Figure Ap 9-1 shows an example of gearshift use for a small vehicle: (a) the lines in bold show the gear use for acceleration phases; (b) the dotted lines show the downshift points for deceleration phases; (c) in the cruising phases, the whole speed range between downshift speed and upshift speed may be used. 2.2 | Where vehicle speed increases gradually during cruise phases, upshift speeds (v1—2, v2—3and vi—i+1) in km/h may be calculated using the following equations: Equation Ap9-3: Equation Ap9-4: Equation Ap9-5: , i = 3 to ng Figure Ap9-1 Example of a gearshift sketch — Gear use during deceleration and cruise phases Gear use during acceleration phases In order to allow the technical service more flexibility and to ensure driveability, the gearshift regression functions should be considered as lower limits. Higher engine speeds are permitted in any cycle phase.
—deleted
driving cycle;
3. Phase indicatorsadded
3.1 | In order to avoid different interpretations in the application of the gearshift equations and thus to improve the comparability of the test, fixed-phase indicators are assigned to the speed pattern of the cycles. The specification of the phase indicators is based on the definition from the Japan Automobile Research Institute (JARI) of the four driving modes as shown in the following table: Table Ap9-1 Definition of driving modes 4 modes Definition Idle mode vehicle speed < 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) Acceleration mode acceleration > 0,5 km/h/s (0,139 m/s2) Deceleration mode acceleration < - 0,5 km/h/s (- 0,139 m/s2) Cruise mode vehicle speed ≥ 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) 4 modes | Definition Idle mode | vehicle speed < 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) Acceleration mode | acceleration > 0,5 km/h/s (0,139 m/s2) Deceleration mode | acceleration < - 0,5 km/h/s (- 0,139 m/s2) Cruise mode | vehicle speed ≥ 5 km/h and -0,5 km/h/s (-0,139 m/s2) < acceleration < 0,5 km/h/s (0,139 m/s2) 3.2 | The indicators were then modified in order to avoid frequent changes during relatively homogeneous cycle parts and thus improve driveability. Figure Ap9-2 shows an example from cycle part 1. Figure Ap9-2 Example for modified phase indicators
—deleted
vehicle soak;
(b)deleted
test phase:
4.1.added
An example of input data necessary for the calculation of shift speeds is shown in Table Ap 9-2. The upshift speeds for acceleration phases for first gear and higher gears are calculated using Equations 9-1 and 9-2. The denormalisation of engine speeds can be performed using the equation .
—deleted
diurnal (breathing loss) test;
4.2.added
The downshift speeds for deceleration phases can be calculated using Equations 9-3 and 9-4. The ndv values in Table Ap 9-2 can be used as gear ratios. These values can also be used to calculate the corresponding vehicle speeds ( . The results are shown in Tables Ap9-3 and Ap9-4.
—deleted
driving cycle;
4.3.added
Additional analyses and calculations were conducted to investigate whether these gearshift algorithms could be simplified and, in particular, whether engine shift speeds could be replaced by vehicle shift speeds. The analysis showed that vehicle speeds could not be brought in line with the gearshift behaviour of the in-use data.
—deleted
hot soak loss test. Mass emissions of hydrocarbons from the tank breathing loss and the hot soak loss phases are added together to provide an overall result for the test.
4.3.1.added
Table Ap9-2 Input data for the calculation of engine and vehicle shift speeds Item | Input data Engine capacity in cm3 | 600 Pn in kW | 72 mk in kg | 199 s in min-1 | 11 800 nidle in min-1 | 1 150 ndv1 (*1) | 133,66 ndv2 | 94,91 ndv3 | 76,16 ndv4 | 65,69 ndv5 | 58,85 ndv6 | 54,04 pmr (*2) in kW/t | 262,8 (*1) ndv means the ratio between engine speed in min-1 and vehicle speed in km/h (*2) pmr means the power-to-mass ratio calculated by 1. Pn / (mk+75) · 1 000 ; Pn in kW, mk in kg
4.3.2.added
Table Ap9-3 Shift speeds for acceleration phases for first gear and for higher gears (see Table Ap9-1) EU/USA/JAPAN DRIVING BEHAVIOUR EU/USA/Japan driving behaviour | n_acc_max (1) n_acc_max (i) n_norm (*1) in percent | 24,9 | 34,9 n in min-1 | 3 804 | 4 869 (*1) n_norm means the value calculated using equations Ap9-1 and Ap9-2.
4.3.3.added
Table Ap9-4 Engine and vehicle shift speeds based on Table Ap9-2 Gearshift | EU/USA/Japan driving behaviour v in km/h | n_norm (i) in percent | n in min-1 Upshift | 1→2 | 28,5 | 24,9 | 3 804 2→3 | 51,3 | 34,9 | 4 869 3→4 | 63,9 | 34,9 | 4 869 4→5 | 74,1 | 34,9 | 4 869 5→6 | 82,7 | 34,9 | 4 869 Downshift | 2→cl (*1) | 15,5 | 3,0 | 1 470 3→2 | 28,5 | 9,6 | 2 167 4→3 | 51,3 | 20,8 | 3 370 5→4 | 63,9 | 24,5 | 3 762 6→5 | 74,1 | 26,8 | 4 005 (*1) ‘cl’ means ‘Clutch-Off’ timing.
3.1. Test vehiclesdeleted
The SHED test shall be conducted at the choice of the manufacturer with one or more degreened test vehicles equipped with: 3.1.1. degreened emission control devices; a fixed deterioration factor of 0,3 g/test shall be added to the SHED test result; 3.1.2. aged evaporative emission control devices; the ageing test procedure set-out in sub-appendix 3.2. shall apply.
3.2. Test vehiclesdeleted
The degreened test vehicle, which shall be representative of the vehicle type with regard to environmental performance to be approved, shall be in good mechanical condition and, before the evaporative test, have been run in and driven at least 1 000 km after first start on the production line. The evaporative emission-control system shall be connected and functioning correctly over this period and the carbon canister and evaporative emission control valve subjected to normal use, undergoing neither abnormal purging nor abnormal loading.
1. Scope of the Appendixadded
This Appendix applies to the type-approval of separate technical units within the meaning of Article 23(10) of Regulation (EU) No 168/2013, of pollution-control devices to be fitted as replacement parts on one or more types of L-category vehicle.
3.3. Test fueldeleted
The appropriate test fuel, as defined in Appendix 2 to Annex II, shall be used.
2. Definitionsadded
‘original equipment pollution-control devices’ mean pollution-control devices including oxygen sensors, catalytic converter types, assemblies of catalytic converters, particulate filters or carbon canisters for evaporative emission control covered by the type-approval and originally delivered for the approved vehicle; ‘replacement pollution-control devices’ means pollution-control devices including oxygen sensors, catalytic converter types, assemblies of catalytic converters, particulate filters or carbon canisters for evaporative emission control intended to replace an original equipment pollution-control device on a vehicle type with regard to environmental and propulsion unit performance approved in accordance with this Appendix and which can be type-approved as a separate technical unit in accordance with Regulation (EU) No 168/2013;
4. Chassis dynamometer and evaporative emission…deleted
4.1. | The chassis dynamometer shall meet the requirements of Appendix 3 of Annex II. 4.2. | Evaporative emission measurement enclosure (SHED)The evaporative emission measurement enclosure shall be a gas-tight rectangular measuring chamber able to contain the vehicle under test. The vehicle shall be accessible from all sides when inside and the enclosure when sealed shall be gas-tight. The inner surface of the enclosure shall be impermeable to hydrocarbons. At least one of the surfaces shall incorporate a flexible impermeable material or other device to allow the equilibration of pressure changes resulting from small changes in temperature. Wall design shall be such as to promote good dissipation of heat. 4.3. | Analytical systems4.3.1. Hydrocarbon analyser 4.3.1.1. The atmosphere within the chamber is monitored using a hydrocarbon detector of the flame ionisation detector (FID) type. Sample gas shall be drawn from the midpoint of one side wall or the roof of the chamber and any bypass flow shall be returned to the enclosure, preferably to a point immediately downstream of the mixing fan. 4.3.1.2. The hydrocarbon analyser shall have a response time to 90 % of final reading of less than 1,5 seconds. Its stability shall be better than 2 % of full scale at zero and at 80 ± 20 % of full scale over a 15-minute period for all operational ranges. 4.3.1.3. The repeatability of the analyser expressed as one standard deviation shall be better than 1 % of full scale defl…
3.1.added
Applications for type-approval of a type of replacement pollution-control device as a separate technical unit shall be submitted by the manufacturer of the system or by his authorised representative.
5.1. Test preparationdeleted
5.1.1. | The vehicle is mechanically prepared before the test as follows: (a) the exhaust system of the vehicle shall not exhibit any leaks; (b) the vehicle may be steam-cleaned before the test; (c) the fuel tank of the vehicle shall be equipped with temperature sensors so that the temperature of the fuel and fuel vapour in the fuel tank can be measured when it is filled to 50 % ± 2 % of its rated capacity; (d) additional fittings, adaptors or devices may optionally be fitted to allow a complete draining of the fuel tank. Alternatively, the fuel tank may be evacuated by means of a pump or siphon that prevents fuel spillage.
3.2.added
A model for the information document is referred to in Article 27(4) of Regulation (EU) No 168/2013.
5.2. Conditioning phasedeleted
5.2.1. | The vehicle shall be taken into the test area where the ambient temperature is between 293,2 K and 303,2 K (20 °C and 30 °C). 5.2.2. | The vehicle is placed on a chassis dynamometer and driven through the test cycle specified in Part A of Annex VI to Regulation (EU) No 168/2013 as appropriate for the class of vehicle being tested. Exhaust emissions may be sampled during this operation but the results shall not be used for the purpose of exhaust emission type-approval. 5.2.3. | The vehicle is parked in the test area for the minimum period stated in Table Ap3-1. Table Ap3-1 SHED test — minimum and maximum soak periods Engine capacity Minimum (hours) Maximum (hours) < 170 cm3 6 36 170 cm3 ≤ engine capacity < 280 cm3 8 36 ≥ 280 cm3 12 36 Engine capacity | Minimum (hours) | Maximum (hours) < 170 cm3 | 6 | 36 170 cm3 ≤ engine capacity < 280 cm3 | 8 | 36 ≥ 280 cm3 | 12 | 36
3.3.added
For each type of replacement pollution-control device for which approval is requested, the type-approval application shall be accompanied by the following documents in triplicate, and by the following particulars: A description of the types of vehicles for which the device is intended, in terms of its characteristics; The numbers or symbols specific to the propulsion and vehicle type; Description of the replacement catalytic converter type stating the relative position of each of its components, together with the fitting instructions; Drawings of each component to facilitate location and identification, and statement of materials used. These drawings shall also indicate the intended location of the mandatory type-approval mark.
3.4.added
The following shall be submitted to the technical service responsible for the type-approval test: Vehicle(s) of a type approved in accordance with this Appendix equipped with a new original equipment pollution-control device type. This (these) vehicles shall be selected by the applicant with the agreement of the technical service to the satisfaction of the approval authority. It (they) shall comply with the requirements of Annex II, type I test. The test vehicles shall be without emission-control system defects and be properly maintained and used; any excessively worn out or malfunctioning emission-related original part shall be repaired or replaced. The test vehicles shall be tuned properly and set to the manufacturer’s specification prior to emission testing. One sample of the type of the replacement pollution-control device type. This sample shall be clearly and indelibly marked with the applicant’s trade name or mark and its commercial designation.
5.3.1. Tank breathing (diurnal) evaporative emiss…deleted
5.3.1.1. The measuring chamber shall be vented/purged for several minutes immediately before the test until a stable background is obtainable. The chamber mixing fan(s) shall be switched on at this time also. 5.3.1.2. The hydrocarbon analyser shall be set to zero and spanned immediately before the test. 5.3.1.3. The fuel tanks shall be emptied as described in point 5.1.1 and refilled with test fuel at a temperature of between 283,2 K and 287,2 K (10 °C and 14 °C) to 50 ± 2 % of its normal volumetric capacity. 5.3.1.4. The test vehicle shall be brought into the test enclosure with the engine switched off and parked in an upright position. The fuel tank sensors and heating device shall be connected, if necessary. Immediately begin recording the fuel temperature and the air temperature in the enclosure. If a venting/purging fan is still operating, it shall be switched off at this time. 5.3.1.5. The fuel and vapour may be artificially heated to the starting temperatures of 288,7 K (15,5 °C) and 294,2 K (21,0 °C) ± 1 K respectively. An initial vapour temperature up to 5 °C above 21,0 °C may be used. For this condition, the vapour shall not be heated at the beginning of the diurnal test. When the fuel temperature has been raised to 5,5 °C below the vapour temperature by following the Tf function, the remainder of the vapour heating profile shall be followed. 5.3.1.6. As soon as the fuel temperature reaches 14,0 °C:
(1)deleted
Install the fuel filler cap(s);
4.1. General requirementsadded
The design, construction and mounting of the replacement pollution-control device type shall be such that: the vehicle complies with the requirements of this Regulation under normal conditions of use, and in particular regardless of any vibrations to which it may be subjected; the replacement pollution-control device displays reasonable resistance to the corrosion phenomena to which it is exposed, with due regard to the normal conditions of use of the vehicle; the ground clearance available with the original equipment pollution-control device type and the angle at which the vehicle can lean over are not reduced; the surface of the device does not reach unduly high temperatures; the outline of the device has no projections or sharp edges; shock absorbers and suspension have adequate clearance; adequate safety clearance is provided for pipes; the replacement pollution-control device is impact-resistant in a way that is compatible with clearly-defined maintenance and installation requirements; if the original equipment pollution-control includes thermal protection, the replacement pollution-control device shall include equivalent protection; if (an) oxygen probe(s) and other sensors or actuators are originally installed on the exhaust line, the replacement pollution-control device type shall be installed at exactly the same position as the original equipment pollution-control device and the position on the exhaust line of the oxygen probe(s) and other sensors or actuators shall…
(2)deleted
Turn off the purge blowers, if not already off at that time;
(3)deleted
Close and seal enclosure doors. As soon as the fuel reaches a temperature of 15,5 °C ± 1 °C the test procedure shall continue as follows:
4.2.1.added
The vehicle referred to in point 3.4.1, equipped with a replacement pollution-control device of the type for which type-approval is requested, shall undergo the tests laid down in Annexes II and VI (depending on the type-approval of the vehicle) ( 6 ). Evaluation of pollutant emissions from vehicles equipped with replacement pollution-control devices Requirements regarding tailpipe or evaporative emissions are deemed to be complied with if the test vehicle equipped with the replacement pollutant-control device complies with the limit values in Annex VI to Regulation (EU) No 168/2013 (according to the type-approval of the vehicle) (6) . Where the type-approval application is for different types of vehicles from the same manufacturer, the type I test may be limited to as few as two vehicles selected after agreement with the technical service to the satisfaction of the approval authority, provided that the different types of vehicle are fitted with the same type of original equipment pollution-control device.
(a)deleted
the hydrocarbon concentration, barometric pressure and the temperature shall be measured to give the initial readings CHC, i, pi and Ti for the tank heat build test;
4.2.2.added
Requirements regarding permissible sound level The vehicles referred to in point 3.4.1, equipped with a replacement pollution-control device type that could allow worse noise emissions than the type for which type-approval is requested, shall satisfy the requirements of Annex IX (according to the type-approval of the vehicle) (6) . The test result for the vehicle in motion and for the stationary test shall be mentioned in the test report.
(b)deleted
a linear heat build of 13,8 °C or 20 °C ± 0,5 °C over a period of 60 ± 2 minutes shall begin. The temperature of the fuel and fuel vapour during the heating shall conform to the function below to within ± 1,7 °C, or the closest possible function as described in 4.4: For exposed type of fuel storage tanks: Equations B.3.3-1 Tf = 0,3333 · t + 15,5 °C Tv = 0,3333 · t + 21,0 °C For non-exposed type of fuel storage tanks: Equations B.3.3-2 Tf = 0,2222 · t + 15,5 °C Tv = 0,2222 · t + 21,0 °C where: Tf | = | required temperature of fuel (°C); Tv | = | required temperature of vapour (°C); t | = | time from start of the tank heat build in minutes. 5.3.1.7. The hydrocarbon analyser is set to zero and spanned immediately before the end of the test. 5.3.1.8. If the heating requirements in point 5.3.1.6. have been met over the 60 ± 2 minute period of the test, the final hydrocarbon concentration in the enclosure is measured (CHC,f). The time or elapsed time of this measurement is recorded, together with the final temperature and barometric pressure Tf and pf. 5.3.1.9. The heat source is turned off and the enclosure door unsealed and opened. The heating device and temperature sensor are disconnected from the enclosure apparatus. The vehicle is now removed from the enclosure with the engine switched off. 5.3.1.10. To prevent abnormal loading of the canister, fuel tank caps may be removed from the vehicle during the period between the end of the diurnal test phase and the start of the drivi…
5.3.2. Driving cycledeleted
5.3.2.1. ‘Tank breathing losses’ means hydrocarbon emissions caused by temperature changes in the fuel storage and supply. Following the tank breathing losses test, the vehicle is pushed or otherwise manoeuvred onto the chassis dynamometer with the engine switched off. It is then driven through the driving cycle specified for the class of vehicle on test. At the request of the manufacturer, exhaust emissions may be sampled during this operation, but the results shall not be used for the purpose of exhaust emission type-approval.
4.3.1.added
The replacement pollution-control device type shall be such as to ensure that the propulsion performance of the vehicle is comparable with that achieved with the original equipment pollution-control device type.
5.3.3. Hot soak evaporative emissions testdeleted
The determination for evaporative emissions is concluded with the measurement of hydrocarbon emissions over a 60-minute hot soak period. The hot soak test shall begin within seven minutes of the completion of the driving cycle specified in point 5.3.2.1. 5.3.3.1. Before the completion of the test run, the measuring chamber shall be purged for several minutes until a stable hydrocarbon background is obtained. The enclosure mixing fan(s) shall also be turned on at this time. 5.3.3.2. The hydrocarbon analyser shall be set to zero and spanned immediately prior to the test. 5.3.3.3. The vehicle shall be pushed or otherwise moved into the measuring chamber with the engine switched off. 5.3.3.4. The enclosure doors are closed and sealed gas-tight within seven minutes of the end of the driving cycle. 5.3.3.5. A 60 ± 0,5 minute hot soak period begins when the chamber is sealed. The hydrocarbon concentration, temperature and barometric pressure are measured to give the initial readings CHC, i. Pi and Ti for the hot soak test. These figures are used in the evaporative emission calculation shown in chapter 6. 5.3.3.6. The hydrocarbon analyser shall be zeroed and spanned immediately before the end of the 60 ± 0,5 minute test period. 5.3.3.7. At the end of the 60 ± 0,5 minute test period, measure the hydrocarbon concentration in the chamber. The temperature and the barometric pressure are also measured. These are the final readings CHC, f. pf and Tf for the hot soak test used for the calc…
4.3.2.added
The propulsion performance of the vehicle equipped with the replacement pollution-control device shall be compared with that of an original equipment pollution-control device, also in new condition, fitted in turn to the vehicle referred to in point 3.4.1.
5.4. Alternative test proceduresdeleted
5.4.1. | At the request of the manufacturer, with the agreement of the technical service and to the satisfaction of the approval authority, alternative methods may be used to demonstrate compliance with the requirements of this Appendix. In such cases, the manufacturer shall satisfy the technical service that the results from the alternative test can be correlated with those resulting from the procedure described in this Annex. This correlation shall be documented and added to the information folder provided for in Article 27 of Regulation (EU) No 168/2013.
4.3.3.added
This test is carried out according to the applicable procedure set out in Annex X. The maximum net power and torque as well as the maximum attainable vehicle speed, if applicable, measured with the replacement pollution-control device, shall not deviate by more than + 5 % from those measured under the same conditions with the type-approved original equipment pollution-control device type.
6. Calculation of resultsdeleted
6.1. | The evaporative emission tests described in chapter 5 allow the hydrocarbon emissions from the tank breathing and hot soak phases to be calculated. Evaporative losses from each of these phases is calculated using the initial and final hydrocarbon concentrations, temperatures and pressures in the enclosure, together with the net enclosure volume. The following formula shall be used: Equation Ap3-3: where: MHC = mass of hydrocarbon emitted over the test phase (grams); CHC = hydrocarbon concentration measured in the enclosure (ppm (volume) Ci equivalent); V = net enclosure volume in cubic metres corrected for the volume of the vehicle. If the volume of the vehicle is not determined, a volume of 0,14 m3 shall be subtracted; T = ambient chamber temperature in K; p = barometric pressure in kPa; H/C = hydrogen to carbon ratio; where: i is the initial reading; f is the final reading; H/C is taken to be 2,33 for tank breathing losses; H/C is taken to be 2,20 for hot soak losses. ‘Hot soak losses’ means hydrocarbon emissions arising from the fuel system of a stationary vehicle after a period of driving (assuming a ratio of C1 H2,20 ); MHC | = | mass of hydrocarbon emitted over the test phase (grams); CHC | = | hydrocarbon concentration measured in the enclosure (ppm…
7. Limit valuesdeleted
When tested according to this Annex, overall evaporative hydrocarbon mass emission for the vehicle (Mtotal) shall be as specified in Part C of Annex VI to Regulation (EU) No 168/2013.
8. Further provisionsdeleted
At the request of the manufacturer, evaporative emission approval shall be granted without testing if a California Executive Order for the vehicle type with regard to environmental performance for which application is made can be provided to the approval authority.
1.1.added
This Appendix defines the specific provisions regarding type-approval of hybrid electric L-category vehicles (HEV).
1. Scopedeleted
1.1. The following preconditioning requirements before starting the SHED test shall apply only to L-category vehicles equipped with a hybrid propulsion.
1.2.added
In principle, for the environmental type I to IX tests, hybrid electric vehicles shall be tested in accordance with this Regulation, unless otherwise provided for in this Appendix.
2. Test methodsdeleted
2.1. Before starting the SHED test procedure, the test vehicles shall be preconditioned as follows: 2.1.1. OVC vehicles. 2.1.1.1. As regards OVC vehicles without an operating mode switch, the procedure shall start with the discharge of the electrical energy/power storage device of the vehicle while driving (on the test track, on a chassis dynamometer, etc.) in any of the following conditions:
1.3.added
For the type I and type VII tests, off-vehicle charging (OVC) vehicles (as categorised in point 2) shall be tested according to Conditions A and B. Both sets of test results and the weighted values shall be reported in the test report drafted in accordance with the template referred to in Article 32(1) of Regulation (EU) No 168/2013.
(a)deleted
at a steady speed of 50 km/h until the fuel-consuming engine of the HEV starts up;
1.4.added
The emissions test results shall comply with the limits set-out in Regulation (EU) No 168/2013 under all test conditions specified in this Regulation.
(b)deleted
if a vehicle cannot reach a steady speed of 50 km/h without the fuel-consuming engine starting up, the speed shall be reduced until it can run at a lower steady speed at which the fuel-consuming engine does not start up for a defined time or distance (to be determined by the technical service and the manufacturer);
2. Categories of hybrid vehiclesadded
Table Ap11-1 Hybrid vehicle categories Vehicle charging | Off-Vehicle Charging (1) (OVC) | Not-off-vehicle Charging (2) (NOVC) Operating mode switch | Without | With | Without | With (1) Also known as ‘externally chargeable’. (2) Also known as ‘not externally chargeable’.
(c)deleted
in accordance with the manufacturer’s recommendation. The fuel-consuming engine shall be stopped within ten seconds of being automatically started. 2.1.1.2. As regards OVC vehicles with an operating mode switch, the procedure shall start with the discharge of the electrical energy/power storage device of the vehicle while driving with the switch in pure electric position (on the test track, on a chassis dynamometer, etc.) at a steady speed of 70 percent ± 5 percent from the maximum thirty minutes speed of the vehicle. By means of derogation if the manufacturer can prove to the technical service to the satisfaction of the approval authority that the vehicle is physically not capable of achieving the thirty minutes speed the maximum fifteen minute speed may be used instead. Stopping the discharge occurs in any of the following conditions:
3. Type I test methodsadded
For the type I test, hybrid electric L-category vehicles shall be tested according to the applicable procedure in Annex VI to Regulation (EU) No 168/2013. For each test condition, the pollutant emission test result shall comply with the limits in Parts A1 and A2 of Annex VI to Regulation (EU) No 168/2013, whichever is applicable in accordance with Annex IV to Regulation (EU) No 168/2013.
(a)deleted
when the vehicle is not able to run at 65 percent of the maximum thirty minutes speed;
3.1. Externally chargeable vehicles (OVC HEVs) wi…added
3.1.1. | Two tests shall be performed under the following conditions: (a) condition A: the test shall be carried out with a fully charged electrical energy/power storage device. (b) condition B: the test shall be carried out with an electrical energy/power storage device in minimum state of charge (maximum discharge of capacity). The profile of the state of charge (SOC) of the electrical energy/power storage device during different stages of the test is given in Appendix 3.1. to Annex VII. 3.1.2. | Condition A 3.1.2.1. The procedure shall start with the discharge of the electrical energy/power storage device of the vehicle while driving (on the test track, on a chassis dynamometer, etc.) in any of the following conditions: (a) at a steady speed of 50 km/h until the fuel-consuming engine starts up; (b) if a vehicle cannot reach a steady speed of 50 km/h without the fuel-consuming engine starting up, the speed shall be reduced until it can run at a lower steady speed at which the fuel-consuming engine does not start up for a defined time or distance (to be determined by the technical service and the manufacturer subject to the agreement of the approval authority); (c) in accordance with the manufacturer’s recommendation. The fuel-consuming engine shall be stopped within ten seconds of being automatically started. 3.1.2.2. Conditioning of vehicleThe vehicle shall be co…
(b)deleted
when the standard on-board instrumentation gives the driver an indication to stop the vehicle;
(c)deleted
after 100 km. If the vehicle is not equipped with a pure electric mode, the electrical energy/power storage device discharge shall be conducted with the vehicle driving (on the test track, on a chassis dynamometer, etc.) under any of the following conditions:
(a)deleted
at a steady speed of 50 km/h until the fuel-consuming engine of the HEV starts up;
(b)deleted
if a vehicle cannot reach a steady speed of 50 km/h without the fuel-consuming engine starting up, the speed shall be reduced until it can run at a lower steady speed at which the fuel-consuming engine does not start up for a defined time or distance (to be determined by the technical service and the manufacturer);
1.1.added
This Appendix describes the special requirements as regards the testing of LPG, NG/biomethane, H2NG or hydrogen gas for the approval of alternative fuel vehicles that run on those fuels or can run on petrol, LPG, NG/biomethane, H2NG or hydrogen.
(c)deleted
in accordance with the manufacturer’s recommendation. The engine shall be stopped within ten seconds of being automatically started. By means of derogation if the manufacturer can prove to the technical service to the satisfaction of the approval authority that the vehicle is physically not capable of achieving the thirty minutes speed the maximum fifteen minute speed may be used instead. 2.1.2. NOVC vehicles. 2.1.2.1. As regards NOVC vehicles without an operating mode switch, the procedure shall start with a preconditioning of at least two consecutive complete, applicable test type I driving cycles without soak. 2.1.2.2. As regards NOVC vehicles with an operating mode switch, the procedure shall start with a preconditioning of at least two consecutive complete, applicable driving cycles without soak, with the vehicle running in hybrid mode. If several hybrid modes are available, the test shall be carried out in the mode which is automatically set after the ignition key is turned (normal mode). On the basis of information provided by the manufacturer, the technical service shall ensure that the limit values are complied with in all hybrid modes. 2.1.3. The preconditioning drive shall be carried out according to the type I test cycle in Appendix 6 to Annex II: 2.1.3.1. for OVC vehicles this shall be carried out under the same conditions as specified by Condition B of the type I test in Appendix 11 to Annex II. 2.1.3.2. for NOVC vehicles this shall be carried out under the sam…
1.2.added
The composition of these gaseous fuels, as sold on the market, can vary greatly and fuelling systems must adapt their fuelling rates accordingly. To demonstrate this adaptability, the parent vehicle equipped with a representative LPG, NG/biomethane or H2NG fuel system shall be tested in type I tests on two extreme reference fuels.
1.3.added
The requirements of this Appendix as regards hydrogen shall apply only to vehicles using hydrogen as a combustion fuel and not to those equipped with a fuel cell operating on hydrogen.
1. Test methods for ageing of evaporative emiss…deleted
The SHED test shall be conducted with aged evaporative emission control devices fitted. The ageing tests for those devices shall be conducted according to the procedures in this Appendix.
2. Granting of type-approval for an L-category …added
Type-approval is granted subject to the following requirements:
2.1. Exhaust emissions approval of a vehicle equi…added
It shall be demonstrated that the parent vehicle equipped with a representative LPG, NG/biomethane, H2NG or hydrogen fuel system can adapt to any fuel composition that may appear on the market and comply with the following: In the case of LPG there are variations in C3/C4 composition (test fuel requirement A and B) and therefore the parent vehicle shall be tested on reference fuels A and B referred to in Appendix 2; In the case of NG/biomethane there are generally two types of fuel, high calorific fuel (G20) and low calorific fuel (G25), but with a significant spread within both ranges; they differ significantly in Wobbe index. These variations are reflected in the reference fuels. The parent vehicle shall be tested on both reference fuels referred to in Appendix 2; In the case of a flex fuel H2NG vehicle, the composition range may vary from 0 % hydrogen (L-gas) to a maximum percentage of hydrogen within the mixture (H-gas), as specified by the manufacturer. It shall be demonstrated that the parent vehicle can adapt to any percentage within the range specified by the manufacturer and the vehicle shall be tested in the type I test on 100 % H-gas and 100 % L-gas. It shall also be demonstrated that it can adapt to any NG/biomethane composition that may appear on the market, regardless of the percentage of hydrogen in the mixture. For vehicles equipped with hydrogen fuel systems, compliance shall be tested on the single hydrogen reference fuel referred to in Appendix 2. If the t…
2.2. Exhaust emissions approval of a member of th…added
For the type-approval of mono-fuel gas vehicles and bi-fuel vehicles operating in gas mode, fuelled by LPG, NG/biomethane, H2NG or hydrogen, as a member of the propulsion family in Annex XI, a type I test shall be performed with one gaseous reference fuel. For LPG, NG/biomethane and H2NG vehicles, this reference fuel may be either of the reference fuels in Appendix 2. The gas-fuelled vehicle is considered to comply if the following requirements are met: The test vehicle shall comply with the definition of a propulsion family member in Annex XI. If the test fuel requirement is reference fuel A for LPG or G20 for NG/biomethane, the emission result shall be multiplied by the relevant factor ‘r’ if r > 1; if r < 1, no correction is needed. If the test fuel requirement is reference fuel B for LPG or G25 for NG/biomethane, the emission result shall be divided by the relevant factor ‘r’ if r < 1; if r > 1, no correction is needed. At the manufacturer’s request, the type I test may be performed on both reference fuels, so that no correction is needed. The parent vehicle shall comply with the emission limits for the relevant category set out in Annex VI(A) to Regulation (EU) No 168/2013 and for both measured and calculated emissions. If repeated tests are conducted on the same engine, an average shall first be taken of the results on reference fuel G20, or A, and those on reference fuel G25, or B; the ‘r’ factor shall then be calculated from these averages. For the type-approval of a…
Carbon canister gas flow diagram and portsdeleted
A carbon canister representative of the propulsion family of the vehicle as set out in Annex XI shall be selected as test canister and shall be marked in agreement with the approval authority and the technical service.
2.1. Canister ageing test proceduredeleted
In the case of a multiple canister system, each canister shall undergo the procedure separately. The number of test cycles of canister loading and discharging shall correspond to the number set-out in table Ap3.1-1, dwell time and subsequent purging of fuel vapour shall be run to age the test canister at an ambient temperature of 297 ± 2 K as follows:
2.1.1. Canister loading part of the test cycledeleted
2.1.1.1. Loading of the canister shall start within one minute of completing the purge portion of the test cycle. 2.1.1.2. The (clean air) vent port of the canister shall be open and the purge port shall be capped. A mix by volume of 50 % air and 50 % commercially available petrol or test petrol specified in Appendix 2 to Annex II shall enter through the tank port of the test canister at a flow rate of 40 grams/hour. The petrol vapour shall be generated at a petrol temperature of 313 ± 2 K. 2.1.1.3. The test canister shall be loaded each time to 2,0 ± 0,1 grams breakthrough detected by: 2.1.1.3.1. FID reading (using a mini-SHED or similar) or 5 000 ppm instantaneous reading on the FID occurring at the (clean air) vent port; or 2.1.1.3.2. Gravimetrical test method using the difference in mass of the test canister charged to 2,0 ± 0,1 grams breakthrough and the purged canister.
1. Introductionadded
This Appendix contains specific provisions regarding the type-approval of vehicles equipped with a periodically regenerating system.
2.1.2. Dwell timedeleted
A five minute dwell period between canister loading and purging as part of the test cycle shall be applied.
2. Scope of the type-approval for vehicles with…added
2.1. | L-category vehicles falling within the scope of Regulation (EU) No 168/2013 that are equipped with periodically regenerating systems shall comply with the requirements in this Appendix. 2.2. | Instead of carrying out the test procedures in the following point, a fixed Ki value of 1,05 may be used if the technical service sees no reason why this value could be exceeded and after approval of the approval authority. 2.3. | During cycles where regeneration occurs, emission standards can be exceeded. If a regeneration of an anti-pollution device occurs at least once per Type I test and that has already regenerated at least once during the vehicle preparation cycle, it will be considered as a continuously regenerating system which does not require a special test procedure.
2.1.3 Canister purging part of the test cycledeleted
2.1.3.1. The test canister shall be purged through the purge port and the tank port shall be capped. 2.1.3.2. Four hundred canister bed volumes shall be purged at a rate of 24 l/min into the vent port. 2.1.4. | Table Ap3.2-1 Amount of test cycles of charging and purging the test canister Vehicle category Vehicle category name Number of test cycles referred to in L1e-A Powered cycle 45 L3e-AxT (x=1, 2 or 3) Two-wheel trial motorcycle L1e-B Two-wheel moped 90 L2e Three-wheel moped L3e-AxE (x=1, 2 or 3) Two-wheel Enduro motorcycle L6e-A Light on-road quad L7e-B Heavy all-terrain quad L3e & L4e (vmax< 130 km/h) Two-wheel motorcycle, with and without side-car 170 L5e Tricycle L6e-B Light quadri-mobile L7e-C Heavy quadri-mobile L3e &L4e (vmax ≥ 130 km/h) Two-wheel motorcycle, with and without side-car 300 L7e-A Heavy on-road quad Vehicle category | Vehicle category name | Number of test cycles referred to in L1e-A | Powered cycle | 45 L3e-AxT (x=1, 2 or 3) | Two-wheel trial motorcycle L1e-B | Two-wheel moped | 90 L2e | Three-wheel moped L3e-AxE (x=1, 2 or 3) | Two-wheel Enduro motorcycle L6e-A | Light on-road quad L7e-B | Heavy all-terrain quad L3e & L4e (vmax< 130 km/h) | Two-wheel motorcycle, with and without side-car | 170 L5e | Tricycle L6e…
3. Test procedureadded
The vehicle may be equipped with a switch capable of preventing or permitting the regeneration process provided that its operation has no effect on original engine calibration. This switch shall be used for the purpose of preventing regeneration only during loading of the regeneration system and during the pre-conditioning cycles. However, it shall not be used during the measurement of emissions in the regeneration phase; rather, the emission test shall be carried out with the unchanged original equipment manufacturer’s powertrain control unit / engine control unit / drive train control unit if applicable and powertrain software. 3.1. | Measurement of carbon dioxide emission and fuel consumption between two cycles where regenerative phases occur. 3.1.1. The average of carbon dioxide emission and fuel consumption between regeneration phases and during loading of the regenerative device shall be determined from the arithmetic mean of several approximately equidistant (if more than two) type I operating cycles. As an alternative, the manufacturer may provide data to show that carbon dioxide emissions and fuel consumption remain constant (+4 percent) between regeneration phases. In this case, the carbon dioxide emissions and fuel consumption measured during the regular type I test may be used. In any other case, emissions shall be measured for at least two type I operating cycles: one immediately after regeneration (before new loading) and one as immediately as …
3. Ageing test procedure of evaporative emissio…deleted
3.1. The durability test shall actuate control valves, cables, and linkages, where applicable, and be representative for the operation conditions of these parts during the useful life of the vehicle if used under normal conditions and serviced in accordance with the manufacturer's recommendations. The accumulated distance and operation conditions of the type V durability test may be regarded as representative for the useful life of the vehicle. 3.2. Alternatively, the aged evaporative emission control parts tested according to point 3.1. may be replaced with ‘golden’ evaporation emission control valves, cables and linkages complying with the requirements of point 3.5. of Annex VI, to be installed on the type IV test vehicle at the choice of the manufacturer prior to start of the SHED test referred to in Appendix 3.
4. Reportingdeleted
The manufacturer shall report the results of the tests referred to in points 2 and 3 in a test report drafted according to the template referred to in Article 32(1) of Regulation (EU) No 168/2013.
1. Calibration frequency and methodsdeleted
1.1. | All equipment shall be calibrated before its initial use and then as often as necessary, and in any case in the month before type-approval testing. The calibration methods to be used are described in this Appendix.
2.1. Initial determination of enclosure internal …deleted
2.1.1. Before its initial use, the internal volume of the chamber shall be determined as follows. The internal dimensions of the chamber are carefully measured, allowing for any irregularities such as bracing struts. The internal volume of the chamber is determined from these measurements. 2.1.2. The net internal volume is determined by subtracting 0,14 m3 from the internal volume of the chamber. Alternatively, the actual volume of the test vehicle may be subtracted. 2.1.3. The chamber shall be checked as in point 2.3. If the propane mass does not tally to within ± 2 % with the injected mass, corrective action is required.
2.2. Determination of chamber background emissionsdeleted
This operation determines that the chamber contains no materials that emit significant amounts of hydrocarbons. The check shall be carried out when the enclosure is brought into service, after any operations in it which may affect background emissions and at least once per year. 2.2.1. Calibrate the analyser (if required). The hydrocarbon analyser shall be set to zero and spanned immediately before the test. 2.2.2. Purge the enclosure until a stable hydrocarbon reading is obtained. The mixing fan is turned on, if not already on. 2.2.3. Seal the chamber and measure the background hydrocarbon concentration, temperature and barometric pressure. These are the initial readings CHCi. pi and Ti used in the enclosure background calculation. 2.2.4. The enclosure is allowed to stand undisturbed with the mixing fan on for four hours. 2.2.5. The hydrocarbon analyser shall be set to zero and spanned immediately before the end of the test. 2.2.6. At the end of this time, use the same analyser to measure the hydrocarbon concentration in the chamber. The temperature and the barometric pressure are also measured. These are the final readings CHCf. Pf and Tf. 2.2.7. Calculate the change in mass of hydrocarbons in the enclosure over the time of the test in accordance with point 2.4. The background emission of the enclosure shall not exceed 0,4 g.
2.3. Calibration and hydrocarbon retention test o…deleted
The calibration and hydrocarbon retention test in the chamber provides a check on the calculated volume in point 2.1. and also measures any leak rate. 2.3.1. Purge the enclosure until a stable hydrocarbon concentration is reached. Turn on the mixing fan, if it is not already on. The hydrocarbon analyser shall be calibrated (if necessary) then set to zero and spanned immediately before the test. 2.3.2. Seal the enclosure and measure the background concentration, temperature and barometric pressure. These are the initial readings CHCi., pi and Ti used in the enclosure calibration. 2.3.3. Inject approximately 4 grams of propane into the enclosure. The mass of propane shall be measured to an accuracy of ± 2 % of the measured value. 2.3.4. Allow the contents of the chamber to mix for five minutes. The hydrocarbon analyser shall be set to zero and spanned immediately before the following test. Measure the hydrocarbon concentration, temperature and barometric pressure. These are the final readings CHCf, pf and Tf for the calibration of the enclosure. 2.3.5. Using the readings taken in accordance with points 2.3.2 and 2.3.4 and the formula in point 2.4, calculate the mass of propane in the enclosure. This shall be within ± 2 % of the mass of propane measured in accordance with point 2.3.3. 2.3.6. Allow the contents of the chamber to mix for a minimum of four hours. Then measure and record the final hydrocarbon concentration, temperature and barometric pressure. The hydrocarbon analy…
4.1.1.added
Components for adjusting the idling speed for the purposes of this Annex refer to controls for changing the idling conditions of the engine which may be easily operated by a mechanic using only the tools referred to in point 4.1.2. In particular, devices for calibrating fuel and air flows are not considered as adjustment components if their setting requires the removal of the set-stops, an operation which can normally be performed only by a professional mechanic.
2.4. Calculationsdeleted
The calculation of net hydrocarbon mass change within the enclosure shall be used to determine the chamber’s hydrocarbon background and leak rate. Initial and final readings of hydrocarbon concentration, temperature and barometric pressure are used in the following formula to calculate the mass change: Equation Ap3-5: where: MHC | = | mass of hydrocarbon in grams; CHC | = | hydrocarbon concentration in the enclosure (ppm carbon (NB: )); V | = | net enclosure volume in cubic metres as measured in accordance with point 2.1.1; T | = | ambient temperature in the enclosure, K; p | = | barometric pressure in kPa; k | = | 17,6; where: i is the initial reading; f is the final reading.
4.1.2.added
The tools which may be used to adjust the idling speed are screwdrivers (ordinary or cross-headed), spanners (ring, open-end or adjustable), pliers, Allen keys and a generic scan tool.
3.1. Detector response optimisationdeleted
The FID analyser shall be adjusted as specified by the instrument manufacturer. Propane in air shall be used to optimise the response on the most common operating range.
4.2.1.added
First, a measurement is taken at the setting in accordance with the conditions fixed by the manufacturer.
3.2. Calibration of the HC analyserdeleted
The analyser shall be calibrated using propane in air and purified synthetic air. A calibration curve shall be established as described in points 4.1 to 4.5.
4.2.2.added
For each adjustment component with a continuous variation, a sufficient number of characteristic positions shall be determined. The test shall be carried out with the engine at ‘normal idling speed’ and at ‘high idle speed’. The definition of the possible position of the adjustment components to a just ‘Normal idling speed’ is defined under point 4.2.5. High idle engine speed is defined by the manufacturer but it must be higher than 2 000 min–1. The high idle speed is reached and kept stable by manually operating the throttle pedal or throttle handle.
3.3. Oxygen interference check and recommended li…deleted
The response factor (Rf) for a particular hydrocarbon species is the ratio of the FID C1 reading to the gas cylinder concentration, expressed as ppm C1. The concentration of the test gas shall be such as to give a response of approximately 80 % of full scale deflection, for the operating range. The concentration shall be known to an accuracy of ± 2 % in reference to a gravimetric standard expressed in volume. In addition, the gas cylinder shall be preconditioned for 24 hours at between 293,2 K and 303,2 K (20 °C and 30 °C). Response factors shall be determined when introducing an analyser into service and thereafter at major service intervals. The reference gas to be used is propane balanced with purified air which shall be taken to give a response factor of 1,00. The test gas to be used for oxygen interference and the recommended response factor range are given the following response factor range for Propane and Nitrogen: 0,95 ≤ Rf ≤ 1,05.
4.2.3.added
The measurement of the carbon monoxide content of exhaust gases shall be carried out for all the possible positions of the adjustment components, but for components with a continuous variation only for the positions referred to in point 4.2.2.
4. Calibration of the hydrocarbon analyserdeleted
Each of the normally used operating ranges are calibrated by the following procedure: 4.1. Establish the calibration curve by at least five calibration points spaced as evenly as possible over the operating range. The nominal concentration of the calibration gas with the highest concentrations shall be at least 80 % of the full scale. 4.2. Calculate the calibration curve by the method of least squares. If the resulting polynomial degree is greater than 3, then the number of calibration points shall be at least the number of the polynomial degree plus 2. 4.3. The calibration curve shall not differ by more than 2 % from the nominal value of each calibration gas. 4.4. Using the coefficients of the polynomial derived from point 4.2, a table of indicated reading against true concentration shall be drawn up in steps of no greater than 1 % of full scale. This is to be carried out for each analyser range calibrated. The table shall also contain all of the following:
4.2.4.added
The type II idle test shall be considered passed if one or both of the following conditions is met: the values measured in accordance with point 4.2.3. shall be in compliance with the requirements set out in points 8.2.1.2. of Annex II to Directive 2009/40/EC; if point 8.2.1.2. (a) is selected by the manufacturer, the specific CO level given by the manufacturer shall be entered on the certificate of conformity; If point 8.2.1.2. (b) (ii) is selected by the manufacturer, the highest CO limits (at engine idle: 0,5 %, at high idle: 0,3 %) shall apply. Footnote (6) to point 8.2.1.2. (b) (ii) shall not be applicable for vehicles in the scope of Regulation (EU) No 168/2013. The measured CO value in the Type II test procedure shall be entered on the certificate of conformity; the maximum content obtained by continuously varying each of the adjustment components in turn while all other components are kept stable shall not exceed the limit value referred to in point 4.2.4.1.
(a)deleted
date of calibration;
4.2.5.added
The possible positions of the adjustment components shall be limited by any of the following: the larger of the following two values:
(b)deleted
span and zero potentiometer readings (where applicable), nominal scale;
(a)changed
the highest rotation lowest idling speed which the crankshaft of the engine can attain by activation of the idling speed components; reach;
(c)deleted
reference data of each calibration gas used;
(b)changed
the rotation speed recommended by the manufacturer, plus 250 minus 100 revolutions per minute; the smallest of the following three values:
(d)deleted
the actual and indicated value of each calibration gas used together with the percentage differences. 4.5. Alternative technology (e.g. computer, electronically controlled range switch) may be used if it can be shown to the satisfaction of the approval authority that it can ensure equivalent accuracy.
(a)added
the highest rotation speed which the crankshaft of the engine can attain by activation of the idling speed components;
(b)added
the rotation speed recommended by the manufacturer, plus 250 revolutions per minute;
1. General requirementsdeleted
1.1. The test vehicles’ powertrain and pollution-control device type fitted on the test vehicles shall be documented and listed by the manufacturer. The list shall include at a minimum such items as the specifications of the propulsion type and its powertrain, where applicable, the exhaust oxygen sensor(s), catalytic converter(s) type, particulate filter(s) or other pollution-control devices, intake and exhaust systems and any peripheral device(s) that may have an impact on the environmental performance of the approved vehicle. This documentation shall be added to the test report. 1.2. The manufacturer shall provide evidence of the possible impacts on type V test results of any modification to the emission abatement system configuration, the pollution-control device type specifications or other peripheral device(s) interacting with the pollution-control devices, in production of the vehicle type after environmental performance type-approval. The manufacturer shall provide the approval authority with this documentation and evidence upon request in order to prove that the durability performance of the vehicle type with regard to environmental performance will not be negatively affected by any change in vehicle production, retrospective changes in the vehicle configuration, changes in the specifications of any pollution-control device type, or changes in peripheral devices fitted on the approved vehicle type. 1.3. Category L4e motorcycles with side-car shall be exempted from ty…
(c)changed
the cut-in rotation speed of automatic clutches. 4.2.6. Settings incompatible with the correct running of the engine shall not be adopted as measurement settings. In particular, if the engine is equipped with several carburettors, all the carburettors shall have the same setting. 4.3. | The following parameters shall be measured and recorded at normal idling speed and at high idle speed: (a) the carbon monoxide (CO) content by volume of the exhaust gases emitted (in vol %); (b) the carbon dioxide (CO2) content by volume of the exhaust gases emitted (in vol %); (c) hydrocarbons (HC) in ppm; (d) the oxygen (O2) content by volume of the exhaust gases emitted (in vol %) or lambda, as chosen by the manufacturer; (e) the engine speed during the test, including any tolerances; (f) the engine oil temperature at the time of the test. Alternatively, for liquid cooled engines, the coolant temperature shall be acceptable. 4.3.1. With respect to the parameters under point 4.3. (d) the following shall apply: 4.3.1.1. the measurement shall only be conducted at high idle engine speed; 4.3.1.2. vehicles in the scope of this measurement are only those equipped with a closed loop fuel system; 4.3.1.3. exemptions for vehicle with: 4.3.1.3.1. engines equipped with a mechanically-controlled (spring, vacuum) secondary air system; 4.3.1.3.2. two-stroke engines operated on a mix of fuel and lubrication oil.
4.2.6.added
Settings incompatible with the correct running of the engine shall not be adopted as measurement settings. In particular, if the engine is equipped with several carburettors, all the carburettors shall have the same setting. 4.3. | The following parameters shall be measured and recorded at normal idling speed and at high idle speed: (a) the carbon monoxide (CO) content by volume of the exhaust gases emitted (in vol %); (b) the carbon dioxide (CO2) content by volume of the exhaust gases emitted (in vol %); (c) hydrocarbons (HC) in ppm; (d) the oxygen (O2) content by volume of the exhaust gases emitted (in vol %) or lambda, as chosen by the manufacturer; (e) the engine speed during the test, including any tolerances; (f) the engine oil temperature at the time of the test. Alternatively, for liquid cooled engines, the coolant temperature shall be acceptable. 4.3.1. With respect to the parameters under point 4.3. (d) the following shall apply: 4.3.1.1. the measurement shall only be conducted at high idle engine speed; 4.3.1.2. vehicles in the scope of this measurement are only those equipped with a closed loop fuel system; 4.3.1.3. exemptions for vehicle with: 4.3.1.3.1. engines equipped with a mechanically-controlled (spring, vacuum) secondary air system; 4.3.1.3.2. two-stroke engines operated on a mix of fuel and lubr…
2.1.added
The manufacturer shall provide the approval authority with technical details and drawings to prove that the engine is or engines are so constructed as to prevent any fuel, lubrication oil or crankcase gases from escaping to the atmosphere from the crankcase gas ventilation system.
2.2.added
Only in the following cases shall the technical service and approval authority require the manufacturer to carry out the type III test: for new vehicle types and new engine types with regard to environmental performance equipped with a new design of the crankcase gas ventilation system, in which case a parent vehicle, with a crankcase gas ventilation concept representative of that approved, may be selected if the manufacturer so chooses to demonstrate to the satisfaction of the technical service and approval authority that the type III test has been passed; if there is any doubt that any fuel, lubrication oil or crankcase gases might escape to the atmosphere from the crankcase gas ventilation system, the technical service and the approval authority may require the manufacturer to conduct the type III test in accordance with point 4.1 or 4.2 (as chosen by the manufacturer).
2.3.added
In all other cases, the type III test shall be waived.
2.4.added
L-category vehicles equipped with a two-stroke engine containing a scavenging port between the crank case and the cylinder(s) may be exempted from the type III test requirements at the request of the manufacturer.
2.5.added
The manufacturer shall attach a copy of the test report on the parent vehicle with the positive result from the type III test to the information folder provided for in Article 27 of Regulation (EU) No 168/2013.
3.1.added
The type III test shall be carried out on a test vehicle which has been subjected to the type I testing in Annex II and the type II testing in Annex III.
3.2.added
The vehicle tested shall have a leak-proof engine or leak-proof engines of a type other than those so designed that even a slight leak may cause unacceptable operating faults. The test vehicle shall be properly maintained and used.
4.1. Test method 1added
The type III test shall be conducted in accordance with the following test procedure: 4.1.1. | Idling shall be regulated in conformity with the manufacturer’s recommendations. 4.1.2. | Measurements shall be taken in the following sets of conditions of engine operation: Table 3-1 Idle operation or steady state vehicle test speeds and power absorbed by the chassis dynamometer during the type III test Condition number Vehicle speed (km/h) 1 Idling 2 Highest of: (a) 50 ±2 (in 3rd gear or ‘drive’) or (b) if (a) not achievable, 50 % of max. design vehicle speed. 3 Condition number Power absorbed by the brake 1 Nil 2 That corresponding to the setting for type I test at 50 km/h or if not achievable type I test at 50 % of max. design vehicle speed. 3 As for condition 2, multiplied by a factor of 1,7 Condition number | Vehicle speed (km/h) 1 | Idling 2 | Highest of: (a) 50 ±2 (in 3rd gear or ‘drive’) or (b) if (a) not achievable, 50 % of max. design vehicle speed. 3 Condition number | Power absorbed by the brake 1 | Nil 2 | That corresponding to the setting for type I test at 50 km/h or if not achievable type I test at 50 % of max. design vehicle speed. 3 | As for condition 2, multiplied by a factor of 1,7 4.1.3. | For all operation conditions listed in point 4.1.2., the reliable functioning of the crankcase ventilation …
4.2. Test method 2added
4.2.1. | The type III test shall be conducted in accordance with the following test procedure. ▼B 4.2.1.1. The engine’s apertures shall be left as found. ▼M2 4.2.1.2. A flexible bag impervious to crankcase gases and having a capacity of approximately 3 times the engine swept volume shall be connected to the dipstick hole. The bag shall be empty before each measurement. ▼B 4.2.1.3. The bag shall be closed before each measurement. It shall be opened to the crankcase for five minutes for each condition of measurement prescribed in point 4.1.2. ▼M2 4.2.1.4. The vehicle shall be deemed satisfactory if, after every condition of measurement defined in points 4.1.2. and 4.2.1.3., no visible inflation of the bag occurs. ▼B 4.2.2. | If the structural layout of the engine is such that the test cannot be performed by the methods described in point 4.2.1., the measurements shall be effected by that method modified as follows: 4.2.2.1. Before the test, all apertures other than that required for the recovery of the gases shall be closed; 4.2.2.2. The bag shall be placed on a suitable take-off which does not introduce any additional loss of pressure and is installed on the recycling circuit of the device directly at the engine-connection aperture. 4.2.2.3. Figure 3-1 Various test set-ups for type III test method No 1 ▼M2 4.2.2.4. If one or more of the conditions of the test def…
Test type IV requirements: evaporative emissionsadded
Appendix Number | Appendix title 1 | Fuel storage permeability test procedure 2 | Fuel storage and delivery system permeation test procedure 3 | Sealed Housing for Evaporation Determination (SHED) test procedure 3.1. | Preconditioning requirements for a hybrid application before start of the SHED test 3.2. | Ageing test procedure for evaporative emission control devices 4 | Calibration of equipment for evaporative emission testing
1.1.added
This Annex describes the procedure for type IV testing, as referred to in Part A of Annex V to Regulation (EU) No 168/2013.
1.2.added
Appendix 1 describes the procedure for testing the permeability of non-metallic fuel tank material and shall also be used as preconditioning test cycle for fuel storage testing referred to in Number C8 of Annex II to Regulation (EU) No 168/2013.
1.3.added
Appendices 2 and 3 describe methods for the determination of the loss of hydrocarbons by evaporation from the fuel systems of vehicles equipped with a propulsion type that uses volatile, liquid fuel. Appendix 4 sets out the calibration procedure for evaporative emission test equipment.
2.1.added
The vehicle manufacturer shall prove to the technical service and to the satisfaction of the approval authority that the fuel tank and fuelling system are leak-tight.
2.2.added
The fuelling system tightness shall comply with the requirements referred to in Annex II (C8) to Regulation (EU) No 168/2013.
2.3.added
All L-vehicle (sub-)categories equipped with a non-metallic fuel storage shall be tested according to the permeability test procedure laid down in Appendix 1. At the request of the manufacturer, the fuel permeation test set out in Appendix 2 or the SHED test set out in Appendix 3 may replace the evaporative part of the permeability test set out in Appendix 1.
2.4.added
L-vehicle (sub-)categories L3e, L4e, L5e-A, L6e-A and L7e-A shall be tested according to the SHED test procedure laid down in Appendix 3.
2.5.added
L-vehicle (sub-)categories L1e, L2e, L5e-B, L6e-B, L7e-B and L7e-C - shall be tested either in accordance with the permeation test procedure set out in Appendix 2 or the SHED test procedure set out in Appendix 3, at the choice of the manufacturer.
1. Scopeadded
1.1. | This requirement shall apply to all L-category vehicles equipped with a non-metallic fuel tank to store liquid, volatile fuel, as applicable for vehicles equipped with a positive ignition combustion engine. 1.2. | Vehicles complying with the requirements set out in Appendix 2 or 3 or vehicles equipped with a compression ignition engine using low volatile fuel shall comply with the requirements of this Appendix only as preconditioning procedure for fuel storage testing referred to in Number C8 of Annex II to Regulation (EU) No 168/2013. The fuel tanks on those vehicles are exempted from the evaporative requirements set out in points 2.1.5, 2.1.6, 2.3. and 2.4.
ANNEX VIchanged
Test type V requirements: durability of pollution-control devices Appendix Number | Appendix title 1 | The Standard Road Cycle for L-Category Vehicles (SRC-LeCV) 2 | The USA EPA Approved Mileage Accumulation durability cycle 0.1. This Annex describes the procedures for type V testing to verify the 3 | Bench ageing durability of pollution-control devices of L-category vehicles in accordance with Article 23(3) of Regulation (EU) No 168/2013. 0.2. The type V test procedure includes mileage accumulation procedures to age the test vehicles in a defined and repeatable way and also includes the frequency of applied type I emission verification test procedures conducted before, during and after the mileage accumulation of the test vehicles. 4 | Standard bench cycle (SBC)
3.3. The mathematical durability procedurechanged
L-category vehicles using the mathematical durability procedure shall refer to point 3(c) of Article 23 of Regulation (EU) No 168/2013. 3.3.1. | The emission results of the vehicle that has accumulated more than 100 km the distance prescribed in Article 23(3)(c) of Regulation (EU) No 168/2013 after it was first started at the end of the production line, the applied deterioration factors set out in Part B of Annex VII to Regulation (EU) No 168/2013, and the product of the multiplication of both and the emission limit set out in Annex VI to Regulation (EU) No 168/2013 shall be added to the test report.
3.4.2. The USA EPA Approved Mileage Accumulation …changed
At the choice of the manufacturer, the AMA durability approved mileage accumulation (AMA) durability cycle may be conducted as alternative type V mileage accumulation cycle up to and including the last date of registration set out in point 1.5.2. of Annex IV to Regulation (EU) No 168/2013. cycle. The AMA durability mileage accumulation cycle shall be conducted according to in accordance with the technical details laid down in Appendix 2. 3.4.3. | The AMA durability cycle is phased out for vehicles of class III referred to in Table AP2-1 in Appendix 2 but may be used in a transitional period up to 31 December 2024.
(a)changed
density: measured on the test fuel according to ISO 3675:1998 or an equivalent method. For petrol and diesel fuel, the density measured at 288,2 K (15 °C) and 101,3 kPa shall be used; for LPG, natural gas, H2NG and hydrogen, a reference density shall be used, as follows: 0,538 kg/litre for LPG; 0,654 kg/m3 for NG ( 8 ) / biogas; Equation 7-1: for H2NG (with A being the quantity of NG/biomethane in the H2NG mixture, expressed in percent by volume for H2NG); 0,084 kg/m3 for hydrogen
(b)changed
hydrogen-carbon ratio: fixed values will be used, as follows: C1:1,89O0,016 for E5 petrol; C1:1,86O0,005 for diesel; C1:2525 for LPG (liquefied petroleum gas); C1:4 for NG (natural gas) and biomethane; C1:2,74O0,385 for ethanol (E85).
4.1. Vehicles powered by an internal combustion e…changed
A type-approval may be extended to vehicles produced by the same manufacturer that are of the same type or of a type that differs with regard to the following characteristics in Appendix 1, provided the CO2 emissions measured by the technical service do not exceed the type-approved value by more than 4 percent: 4.1.1. reference mass; 4.1.2. maximum authorised mass.; 4.1.3. type of bodywork; 4.1.4. overall gear ratios; 4.1.5. engine equipment and accessories; 4.1.6. engine revolutions per kilometre in highest gear with an accuracy of +/– 5 %. 4.2. | Vehicles powered by an internal combustion engine only and equipped with a periodically regenerating emission-control system. The type-approval may be extended to vehicles produced by the same manufacturer that are of the same type or of a type that differs with regard to the characteristics in Appendix 1, as referred to in points 4.1.1. to 4.1.6., without exceeding the propulsion family characteristics of Annex XI, provided the CO2 emissions measured by the technical service do not exceed the type-approved value by more than 4 percent, where the same Ki factor is applicable. The type-approval may also be extended to vehicles of the same type, but with a different Ki factor, provided the corrected CO2 value measured by the technical service does not exceed the type-approved value by more than 4 percent. 4.3. | Vehicles powered by an electric powertrain onlyExtensions may be granted after agreement with the approval authority. 4.4. | Vehicles powered by a hybrid electric powertrainThe type-approval may be extended to vehicles of the same type or of a type that differs with regard to the following characteristics in Appendix 3 provided the CO2 emissions and the electric energy consumption measured by the technical service do not exceed the type-approved value by more than 4 percent: 4.4.1. reference mass; 4.4.2. maximum authorised mass; 4.4.3. type of bodywork; 4.4.4. type and number of propulsion batteries. Where multiple batteries are fitted, e.g. to extend the range extrapolation of the measurement, the base configuration, taking into account the capacities and the way in which the batteries are connected (in parallel, not in series), shall be deemed sufficient. 4.5. | Where any other characteristic is changed, extensions may be granted after agreement with the approval authority.
8. OBD environmental verification test procedur…changed
8.1. | The operating test cycle on the chassis dynamometer shall meet the requirements of Annex II. ▼M2 8.1.1. The Type I test need not be performed for the demonstration of electrical failures (short/open circuit). The manufacturer may demonstrate these failure modes using driving conditions in which the component is used and the monitoring conditions are encountered. Those conditions shall be documented in the type approval documentation. ▼B 8.1.1. | The Type I test need not be performed for the demonstration of electrical failures (short/open circuit). The manufacturer may demonstrate these failure modes using driving conditions in which the component is used and the monitoring conditions are encountered. Those conditions shall be documented in the type approval documentation. 8.2. | Vehicle preconditioning 8.2.1. According to the propulsion type and after introduction of one of the failure modes referred to in point 8.3., the vehicle shall be preconditioned by driving at least two consecutive appropriate type I tests. For vehicles equipped with a compression-ignition engine, additional preconditioning of two appropriate type I test cycles is permitted. 8.2.2. At the request of the manufacturer, alternative preconditioning methods may be used. ▼M2 8.2.3. The use of additional preconditioning cycles or alternative preconditioning methods shall be documented in the type approval documentation. ▼B 8.3. | Failure modes to be tested 8.3.1. For positive-ignition propelled vehicles: 8.3.1.1. Replacement of the catalytic converter type with a deteriorated or defective catalytic converter or electronic simulation of such a failure; 8.3.1.2. Engine misfire conditions in line with those for misfire monitoring referred to in Annex II (C11) to Regulation (EU) No 168/2013; 8.3.1.3. Replacement of the oxygen sensor with a deteriorated or defective sensor or electronic simulation of such a failure; 8.3.1.4. Electrical disconnection of any other emission-related component connected to a powertrain control unit / engine control unit (if active on the selected fuel type); 8.3.1.5. Electrical disconnection of the electronic evaporative purge control device (if equipped and if active on the selected fuel type). For this specific failure mode, the type I test need not be performed. 8.3.2. For vehicles equipped with a compression-ignition engine: 8.3.2.1. Replacement of the catalytic converter type, where fitted, with a deteriorated or defective catalytic converter or electronic simulation of such a failure; 8.3.2.2. Total removal of the particulate filter, where fitted, or, where sensors are an integral part of the filter, a defective filter assembly; 8.3.2.3. Electrical disconnection of any electronic fuel quantity and timing actuator in the fuelling system; 8.3.2.4. Electrical disconnection of any other emission-related or functional safety-relevant component connected to any control unit of the powertrain, the propulsion units or the drive train; 8.3.2.5. In meeting the requirements of points 8.3.2.3. and 8.3.2.4. and with the agreement of the approval authority, the manufacturer shall take appropriate steps to demonstrate that the OBD system will indicate a fault when disconnection occurs. 8.3.3. The manufacturer shall demonstrate that malfunctions of the EGR flow and cooler, where fitted, are detected by the OBD system during its approval test. 8.3.4. Any powertrain malfunction that triggers any operating mode which significantly reduces engine torque (i.e. by 10 % or more in normal operation) shall be detected and reported by the powertrain / engine control system. 8.4. | OBD system environmental verification tests 8.4.1. Vehicles fitted with positive-ignition engines: ▼M2 8.4.1.1. After vehicle preconditioning in accordance with point 8.2., the test vehicle is driven over the appropriate type I test. The malfunction indicator shall activate before the end of this test under any of the conditions given in points 8.4.1.2. to 8.4.1.6. The MI may also be activated during preconditioning. The approval authority may substitute those conditions with others in accordance with point 8.4.1.6. However, the total number of failures simulated shall not exceed four for the purpose of type-approval. For bi-fuelled gas vehicles, both fuel types shall be used within the maximum of four simulated failures at the discretion of the approval authority. authority; ▼B 8.4.1.2. Replacement of a catalytic converter type with a deteriorated or defective catalytic converter or electronic simulation of a deteriorated or defective catalytic converter that results in emissions exceeding the THC OBD threshold, or if applicable the NMHC OBD threshold, in Part B of Annex VI to Regulation (EU) No 168/2013; 8.4.1.3. An induced misfire condition in line with those for misfire monitoring referred to in Annex II (C11) of Regulation (EU) No 168/2013 that results in emissions exceeding any of the OBD thresholds given in Part B of Annex VI to Regulation (EU) No 168/2013; 8.4.1.4. Replacement of an oxygen sensor with a deteriorated or defective oxygen sensor or electronic simulation of a deteriorated or defective oxygen sensor that results in emissions exceeding any of OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013; 8.4.1.5. Electrical disconnection of the electronic evaporative purge control device (if equipped and if active on the selected fuel type); 8.4.1.6. Electrical disconnection of any other emission-related powertrain component connected to a powertrain control unit / engine control unit / drive train control unit that results in emissions exceeding any of the OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013 or triggers an operation mode with significantly reduced torque as compared with normal operation. 8.4.2. Vehicles fitted with compression-ignition engines. 8.4.2.1. After vehicle preconditioning in accordance with point 8.2., the test vehicle is driven in the applicable type I test. The malfunction indicator shall activate before the end of this test under any of the conditions in points 8.4.2.2. to 8.4.2.5. The approval authority may substitute those conditions by others in accordance with point 8.4.2.5. However, the total number of failures simulated shall not exceed four for the purposes of type-approval; 8.4.2.2. Replacement of a catalytic converter type, where fitted, with a deteriorated or defective catalytic converter or electronic simulation of a deteriorated or defective catalytic converter that results in emissions exceeding any of the OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013; 8.4.2.3. Total removal of the particulate filter, where fitted, or replacement of the particulate filter with a defective particulate filter meeting the conditions laid down in point 8.4.2.2. that results in emissions exceeding any of the OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013. 8.4.2.4. With reference to point 8.3.2.5., disconnection of any electronic fuel quantity and timing actuator in the fuelling system that results in emissions exceeding any of the OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013; 8.4.2.5. With reference to point 8.3.2.5., disconnection of any other powertrain component connected to a powertrain control unit / engine control / drive train control unit that results in emissions exceeding any of the OBD thresholds in Part B of Annex VI to Regulation (EU) No 168/2013 or that triggers an operation mode with a significantly reduced torque as compared with normal operation. 8.4.3. Replacement of the NOx after-treatment system, where fitted, with a deteriorated or defective system or electronic simulation of such a failure. 8.4.4. Replacement of the particulate matter monitoring system, where fitted, with a deteriorated or defective system or electronic simulation of such a failure.
2. Definitionschanged
2.1. ‘variable cam phasing or lift’ means allowing the lift, the opening and closing duration or timing of the intake or exhaust valves to be modified while the engine is in operation; 2.2. ‘communication protocol’ means a system of digital message formats and rules for messages exchanged in or between computing systems or units; 2.3. ‘common rail’ means a fuel supply system to the engine in which a common high pressure is maintained; 2.4. ‘intercooler’ means a heat exchanger that removes waste heat from the compressed air by a charger before entering into the engine, thereby improving volumetric efficiency by increasing intake air charge density; 2.5. ‘electronic throttle control’ (ETC) means the control system consisting of sensing of driver input via the accelerator pedal or handle, data processing by the control unit(s), resulting actuation of the throttle and throttle position feedback to the control unit in order to control the air charge to the combustion engine; 2.6. ‘boost control’ means a device to control the boost level produced in the induction system of a turbocharged or supercharged engine; 2.7. ‘SCR system’ means a system capable of converting gaseous pollutants into harmless or inert gases by injecting a consumable reagent, which is a reactive substance to reduce tailpipe emissions and which is adsorbed onto a catalytic converter; 2.8. ‘lean NOx adsorber’ means a storage of NOx fitted into the exhaust system of a vehicle which is purged by the release of a reactant in the exhaust flow; 2.9. ‘cold-start device’ means a device that temporarily enriches the air/fuel mixture of the engine, thus assisting the engine to start; 2.10. ‘starting aid’ means a device which assists engine start up without enrichment of the air/fuel mixture such as glow plugs, injection timing and spark delivery adaptations; ‘exhaust gas recirculation (EGR) system’ means part of the exhaust gas flow led back to or remaining in the combustion chamber of an engine in order to lower the combustion temperature;
1.changed
Part A of Annex V to Regulation (EU) No 168/2013 is replaced by the following: ‘(A) Environmental tests and requirements L-category vehicles may be type-approved only if they comply with the following environmental requirements: Test type | Description | Requirements: limit values | Subclassification criteria in addition to Article 2 and Annex I | Requirements: test procedures I | Tailpipe emissions after cold start | Annex VI (A) | Point 4.3 of Annex II to Commission Delegated Regulation (EU) No 134/2014 | Annex II to Commission Delegated Regulation (EU) No 134/2014 II | — PI or Hybrid (5) equipped with PI: emissions at idling and increased idling speed — CI or Hybrid with CI engine: free acceleration test | Directive 2009/40/EC (6) | Point 4.3 of Annex II to Commission Delegated Regulation (EU) No 134/2014 | Annex III to Commission Delegated Regulation (EU) No 134/2014 III | Emissions of crankcase gases | Zero emission, closed crankcase. Crankcase emissions shall not be discharged directly into the ambient atmosphere from any vehicle throughout its useful life. | Point 3.2 of Annex XI to Commission Delegated Regulation (EU) No 134/2014 | Annex IV to Commission Delegated Regulation (EU) No 134/2014 IV | Evaporative emissions | Annex VI (C) | Point 3.2 of Annex XI to Commission Delegated Regulation (EU) No 134/2014 | Annex V to Commission Delegated Regulation (EU) No 134/2014 V | Durability of pollution control devices | Annexes VI and VII | SRC-LeCV: point 2 of Appendix 1 to Annex VI to Commission Delegated Regulation (EU) No 134/2014 USA EPA AMA: point 2.1 of Appendix 2 to Annex VI to Commission Delegated Regulation (EU) No 134/2014 | Annex VI to Commission Delegated Regulation (EU) No 134/2014 VI | A test-type VI has not been attributed | Not applicable | Not applicable | Not applicable VII | CO2 emissions, fuel and/or electric energy consumption and electric range | Measurement and reporting, no limit value for type- approval purposes | Point 4.3 of Annex II to Commission Delegated Regulation (EU) No 134/2014 | Annex VII to Commission Delegated Regulation (EU) No 134/2014 VIII | OBD environmental tests | Annex VI (B) | Point 4.3 of Annex II to Commission Delegated Regulation (EU) No 134/2014 | Annex VIII to Commission Delegated Regulation (EU) No 134/2014 IX | Sound level | Annex VI (D) | When UNECE regulations Nos 9, 41, 63 or 92 replace the EU proprietary requirements set out in the delegated act on environmental and propulsion performance requirements, the (sub-) classification criteria laid down in those UNECE regulations (Annex 6) shall be selected with reference to test type IX sound level tests. | Annex IX to Commission Delegated Regulation (EU) No 134/2014’ ( 1 ) ‘Measurement procedure for two-wheel motorcycles equipped with a positive or compression ignition engine with regard to the emissions of gaseous pollutants, CO2 emissions and fuel consumption (UN document reference ECE/TRANS/180/Add2e of 30 August 2005)’ including amendment 1 (UNECE document reference ECE/TRANS/180a2a1e of 29 January 2008). ( 2 ) The WMTC stage 2 is equal to the WMTC stage 1 amended by corrigendum 2 of addendum 2 (ECE/TRANS/180a2c2e of 9 September 2009) and corrigendum 1 of amendment 1 (ECE/TRANS/180a2a1c1e of 9 September 2009). ( 3 ) In addition, the corrigenda and amendments identified in the environmental effect study referred to in Article 23 of Regulation (EU) No 168/2013 will be taken into account, as well as corrigenda and amendments proposed and adopted by UNECE WP29 as continuous improvement of the world-harmonised test cycle for L-category vehicles. ( 4 ) OJ L 326, 24.11.2006, p. 55. ( 5 ) OJ L 42, 12.2.2014, p. 1. ( 6 ) As provided for in this Regulation in the version applicable to the type-approval of that vehicle. ( 7 ) OJ L 141, 6.6.2009, p. 12. ( 8 ) Mean value of G20 and G25 reference fuels at 288,2 K (15 °C). ( 9 ) OJ L 317, 14.11.2012, p. 1. ( 10 ) The test may be carried out in temperature-controlled test chambers where the atmospheric conditions can be controlled. ( 11 ) The torque measuring device shall be calibrated in order to take account of frictional losses. This accuracy may be ± 2 % for the measurements carried out at power levels less than 50 % of the maximum value. It will in all cases be ± 1 % for the measurement maximum torque. ( 12 ) The complete air intake system shall be fitted as provided for the intended application: