Compare versions of UN R118
Uniform technical prescriptions concerning the burning behaviour and/or the capability to repel fuel or lubricant of materials used in the construction of certain categories of motor vehicles
1.2.changed
Part I - Approval of a vehicle type with regard to the burning behaviour and/or the capability to repel fuel or lubricant of the components used in the interior compartment, the engine compartment and any separate heating compartment. compartment and with regard to the burning behaviour of electric cables and cable sleeves or cable conduits used for protecting electric cables in the vehicle
2.2.changed
"Interior compartment" means any compartment intended for passengers, drivers and/or crew. crew bounded by the interior facing surface(s) of: The interior compartment shall be bounded by: (a) The roof; ceiling; (b) The floor; (c) The front, rear and side walls; walls, (d) The doors; (e) The outside glazing; (f) The rear compartment bulkhead, or the plane of the rear seat; (g) Back support.
2.5.changed
"Production materials" means products, in the form of bulk materials (e.g. rolls of upholstery) or preformed components, supplied to a manufacturer for incorporation in a vehicle type approved under this Regulation, or to a workshop for use in the business of vehicle maintenance or repair. As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.2, para. 2. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
2.6.changed
"Seat" means a structure which may or may not be integral with the vehicle structure, complete with trim, intended to seat one adult person. The term covers both an individual seat or part of a bench seat intended to seat one adult person. 1 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2.
2.10.added
"Electrical cable" means a single-core or multi-core cable, when applicable
sheathed, screened and unscreened, two or more cores running side by side
and bonded, twisted, or braided together, including cores to form a single
assembly enabling the transfer of electrical signals from one device to the
other.
2.11.added
"Cable sleeve" means any component that enfolds single cables to a multi-
core cable or electrical harness.
2.12.added
"Cable conduit" means any component that covers electrical cables to guide
or route the cables (e.g. tubes, channels, ducts) or fasten electrical cables to
the vehicle.
3.3.changed
The following must shall be submitted to the Technical Service responsible for conducting the type approval tests:
4.1.changed
If the type submitted for approval to this Regulation meets the requirements of the relevant part(s) of this Regulation, approval of that type shall be granted. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
4.2.changed
An approval number shall be assigned to each type approved. Its first two digits (at present 02 03 corresponding to the 02 03 series of amendments) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party shall not assign the same number to another type of vehicle or component as defined in this Regulation.
4.4.2.changed
The number of this Regulation, followed by the letter "R", "I" to indicate Part I of this Regulation, a dash and the approval number, to the right of the circle prescribed in paragraph 4.4.1.
4.5.changed
Production materials do not need to be individually marked. However, the packaging with which they are supplied must shall be marked with an international approval mark consisting of:
4.5.3.changed
In the vicinity of the circle: 2 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.6/.
4.5.3.1.changed
Symbols indicating the direction which the material may be installed: ↔ For the horizontal direction (see para. 6.2.1.), ↕ For the vertical direction (see paras. 6.2.3. and 6.2.4.), The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.2/Amend.1. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 For the horizontal and vertical directions (see paras. 6.2.1., 6.2.3. and 6.2.4.);
5.changed
Part I: Approval of a vehicle type with regard to the burning behaviour of the components used in the interior compartment, the engine compartment and any separate heating compartment and with regard to the burning behaviour of electric cables and cable sleeves or cable conduits used in the vehicle and/or the capability to repel fuel or lubricant of insulation materials used in the engine compartment and any separate heating compartment
5.2.1.changed
The materials inside and no more than 13 mm beyond the interior compartment, materials of the interior engine compartment, the engine compartment and materials of any separate heating compartment and electric cables, cable sleeves or cable conduits used in the vehicle to be type approved shall meet the requirements of Part II of this Regulation.
5.2.2.changed
The materials and/or equipment used in the interior compartment, the engine compartment and any separate heating compartment and/or in devices approved as components components, electric cables and cable sleeves or cable conduits used in the vehicle shall be so installed as to minimize the risk of flame development and flame propagation.
5.2.4.changed
Any adhesive agent used to affix the interior material to its supporting structure shall not, as far as possible, exacerbate the burning behaviour of the material. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
6.2.1.changed
The following materials shall undergo the test described in Annex 6 to this Regulation: (a) Material(s) and composite material(s) installed in a horizontal position in the interior compartment and, (b) Insulation material(s) installed in a horizontal position in the engine compartment and any separate heating compartment. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 The result of the test shall be considered satisfactory if, taking the worst test results into account, the horizontal burning rate is not more than 100 mm/minute or if the flame extinguishes before reaching the last measuring point. Materials fulfilling the requirements of paragraph 6.2.3. are considered to fulfil the requirements in this paragraph.
6.2.7.1.deleted
6.2.6.changed
6.2.7.2.deleted
6.2.7.changed
6.2.7.3.deleted
6.2.8.added
Materials which are not required to undergo the tests described in Annexes 6
to 8 are:
6.2.7.3.1.deleted
6.2.8.1.added
Parts made of metal or glass;
6.2.7.3.2.deleted
6.2.8.2.added
Each individual seat accessory with a mass of non-metallic material less than
200 g. If the total mass of these accessories exceeds 400 g of non-metallic
material per seat, then each material shall be tested;
6.2.7.4.deleted
6.2.8.3.added
Elements of which the surface area or the volume does not exceed
respectively:
6.2.8.3.1.added
100 cm2 or 40 cm3 for the elements which are connected to an individual
seating place;
6.2.8.3.2.added
300 cm2 or 120 cm3 per seat row and, at a maximum, per linear metre of the
interior of the interior compartment for these elements which are distributed
in the vehicle and which are not connected to an individual seating place;
6.2.8.4.added
Elements for which it is not possible to extract a sample in the prescribed
dimensions as specified in paragraph 3.1. of Annex 6, paragraph 3. of
Annex 7, and paragraph 3.1. of Annex 8.
8.changed
The conformity of production procedures shall comply with those set out in the Agreement, Appendix 2 (E/ECE/324-E/ECE/TRANS/505/Rev.2), Schedule 1 (E/ECE/TRANS/505/Rev.3), with the following requirements:
8.1.changed
Vehicles/components approved under this Regulation shall be so manufactured as to conform to the type approved by meeting the requirements of the relevant part(s) of this Regulation. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
12.2.changed
As from 24 months after the official date of entry into force of the 01 series of amendments, Contracting Parties applying this Regulation shall grant approvals only if the vehicle type or component type to be approved meet the requirements of this Regulation as amended by the 01 series of amendments. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
12.10.changed
Even after the date of entry into force of the 02 series of amendments, approvals of the components to the preceding series of amendments to the regulation shall remain valid and Contracting Parties applying the Regulation shall continue to accept them. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 1
12.11.added
As from the official date of entry into force of the 03 series of amendments,
no Contracting Parties applying this Regulation shall refuse to grant approval
under this Regulation as amended by the 03 series of amendment.
12.12.added
As from 1 September 2019, Contracting Parties applying this Regulation
shall grant approvals only if the vehicle type or component type to be
approved meet the requirements of this Regulation as amended by the 03
series of amendments.
12.13.added
As from 1 September 2021, Contracting Parties applying this Regulation
may refuse first national registration (first entry into service) of a vehicle
which does not meet the requirements of this Regulation as amended by the
03 series of amendments.
12.14.added
Even after the date of entry into force of the 03 series of amendments,
approvals of the components to the preceding series of amendments to the
regulation shall remain valid and Contracting Parties applying the
Regulation shall continue to accept them.
Annex 1
3.3.changed
Materials used for insulation in the engine compartment and/or separate heating compartment, stating for each material 1 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), Annex 7 (document TRANS/WP.29/78/Rev.2, TRANS/WP.29/78/Rev.6, para. 2). 2 Strike out what does not apply. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
3.4.4.changed
4.changed
1 Strike out what does not apply. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 3
Annex 3changed
(Maximum format: A4 (210 x 297 mm)) issued by : Name of administration: concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a vehicle type pursuant to UN Regulation No. 118 Approval No. ……………………. . Extension No. ………………………………… Section I General
1.3.changed
1 Distinguishing number of the country which has granted/extended/refused or withdrawn approval. 2 Strike out what does not apply (there are cases where nothing needs to be deleted, when more than one entry is applicable) b If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered in this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC??123??) c As defined in Annex 7 to the Consolidated Resolution on the Construction of Vehicles (R.E.3) (document TRANS/WP.29/78/Rev.2, TRANS/WP.29/78/Rev.6, para. 2). E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Section II
9.changed
Authority, which may be obtained on request, is attached. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 4
Annex 4changed
(Maximum format: A4 (210 x 297 mm)) issued by : Name of administration: concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a component type pursuant to UN Regulation No. 118 Approval No. ……………………….. Extension No. …………………………………... Section I General 1 Distinguishing number of the country which has granted/extended/refused or withdrawn approval. 2 Strike out what does not apply (there are cases where nothing needs to be deleted, when more than one entry is applicable) b If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered in this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC??123??). E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Section II
9.changed
Authority, which may be obtained on request, is attached. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 4 – Appendix 1
Annex 4 - Appendix 1changed
concerning the type approval of a component type pursuant to UN Regulation No. 118
2.changed
Annex 5changed
Example 1 (See Part I of this Regulation) 021234 031234 a = 8 mm min The above approval mark affixed to a vehicle shows that the type concerned was approved in the Netherlands (E4) pursuant to Part I of UN Regulation No. 118 under approval No. 021234. 031234. The first two digits (02) (03) of the approval number indicate that the approval was granted in accordance with the requirements of the 02 03 series of amendments to UN Regulation No. 118. Example 2 (See part II of this Regulation) 021234 031234 118RII - 001234 a = 8 mm min 2/3 a CD V 2/3 a The above approval mark affixed to a component shows that the type concerned was approved in the Netherlands (E4) pursuant to Part II of UN Regulation No. 118 under approval number 021234. 031234. The first two digits (02) (03) of the approval number indicate that the approval was granted in accordance with the requirements of the 02 03 series of amendments to UN Regulation No. 118. The additional symbol indicates the direction which the component may be installed. The symbol V indicates that the component fulfils the requirements in paragraph 6.2.2. CD The symbol CD indicates an approval as a complete device such as seats, separation walls, etc. The additional symbols are only used if applicable. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 6
2.1.changed
Combustion chamber (Figure 1), preferably of stainless steel and having the dimensions given in Figure 2. The front of the chamber contains a flame-resistant flame- resistant observation window, which may cover the front and which can be constructed as an access panel. The bottom of the chamber has vent holes, and the top has a vent slot all around. The combustion chamber is placed on four feet, 10 mm high. The chamber may have a hole at one end for the introduction of the sample holder containing the sample; in the opposite end, a hole is provided for the gas line. Melted material is caught in a pan (see Figure 3) which is placed on the bottom of the chamber between vent holes without covering any vent hole area. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
Figure 2changed
(Dimensions in millimetres) E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 6
Figure 4changed
(Dimensions in millimetres) E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
3.1.1.changed
The shape and dimensions of samples are given in Figure 6. The thickness of the sample corresponds to the thickness of the product to be tested. It shall not be more than 13 mm. When taking the sample permits, the sample shall have a constant section over its entire length. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 6
3.2.changed
The samples shall be conditioned for at least 24 hours but not more than 7 days at a temperature of 23 °C + ± 2 °C and a relative humidity of 50 + ± 5 per cent and shall be maintained under these conditions until immediately prior to testing.
3.1.3.added
The size of the sample shall be mentioned in the test report.
4.6.changed
Measurement of burning time is completed when the flame has come to the last measuring point or when the flame extinguishes before coming to the last measuring point. If the flame does not reach the last measuring point, measure the burnt distance up to the point where the flame extinguished. Burnt distance is the decomposed part of the sample, which is destroyed on its surface or in the interior by burning. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
5.changed
The burning rate, B1, in millimetres per minute, is given by the formula: B = 60 s/t where: s = the burnt distance, in millimetres; t = the time, in seconds, to burn distance s. 1 The burning rate (B) for each sample is only calculated in the case where the flame reaches the last measuring point or the end of the sample. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 7
2.1.changed
The source of heat is an electric radiator with a useful output of 500 W. The radiating surface must shall be made of a transparent quartz plate with a diameter of 100 + ± 5 mm. The radiated heat from the apparatus, measured on a surface which is situated parallel to the surface of the radiator at a distance of 30 mm, shall be 3 W/cm2.
2.2.changed
For calibration of the radiator, a heat flux meter (radiometer) of the Gardon (foil) type with a design range not exceeding 10 W/cm2 shall be used. The target receiving radiation, and possibly to a small extent convection, shall be flat, circular, not more than 10 mm in diameter and coated with a durable matt black finish. The target shall be contained within a water cooled body the front face of which shall be of highly polished metal, flat, coinciding with the plane of the target and circular, with a diameter of about 25 mm. Radiation shall not pass through any window before reaching the target. The instrument shall be robust, simple to set up and use, insensitive to draughts, and stable in calibration. The instrument shall have an accuracy of within +3 ±3 per cent and a repeatability within 0.5 per cent. The calibration of the heat flux meter shall be checked whenever a recalibration of the radiator is carried out, by comparison with an instrument held as a reference standard and not used for any other purpose. The reference standard instrument shall be fully calibrated at yearly intervals in accordance with a national standard. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
3.changed
The test samples shall measure: 70 mm x 70 mm. Samples shall be taken in the same way from finished products, when the shape of the product permits. When the thickness of the product is more than 13 mm, it shall be reduced to 13 mm by a mechanical process applied to the side which does not face the respective compartment (interior, engine or separate heating compartment). If it is impossible, the test shall be carried out, in accordance with the Technical Service, on the initial width of the material which shall be mentioned in the test report. Composite materials (see paragraph 6.1.3. of the Regulation) shall be tested as if they were of uniform construction. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 7 In the case of materials made of superimposed layers of different composition which are not composite materials, all the layers of material included within a depth of 13 mm from the surface facing towards the respective passenger compartment (interior, engine or separate heating compartment) shall be tested individually. The total mass of the sample to be tested shall be at least 2 g. If the mass of one sample is less, a sufficient number of samples shall be added. If the two faces of the material differ, both faces must shall be tested, which means that eight samples are to be tested. The samples and the cotton wool shall be conditioned for at least 24 hours at a temperature 23 °C ± 2 °C and a relative humidity of 50 ± 5 per cent and shall be maintained under these conditions until immediately prior to testing.
5.changed
Observed phenomena shall be noted in the test-report, such as: (i) The fall of drops, if any, whether flaming or not; (ii) If ignition of the cotton wool has taken place. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
Figure 1changed
2.1.changed
The specimen holder shall consist of a rectangular frame of 560 mm high and shall have two rigidly connected parallel rods spaced 150 mm apart on which pins shall be fitted for mounting the test specimen which is located in a plane at least 20 mm from the frame. The mounting pins shall be not greater than 2 mm in diameter and at least 27 40 mm long. The pins shall be located on the parallel rods at locations shown in Figure 1. The frame shall be fitted onto a suitable support to maintain the rods in a vertical orientation during testing (for the purpose of locating the specimen on the pins in a plane away from the frame, spacer stubs 2 mm in diameter may be provided adjacent to the pins). The specimen holder shown in Figure 1 may be modified in width to allow the fixation of the sample. To fix the sample in a vertical position, a support may be provided consisting of 0.25 mm diameter heat resistant wires that horizontally span the sample at 25 mm intervals along the complete height of the specimen holder. Alternatively, the sample may be fixed by additional clamps to the specimen holder.
2.3.changed
The test apparatus may be placed in a fume cupboard assembly provided that the internal volume is at least 20 times, but not more than 110 times, greater than the volume of the test apparatus assembly. The size and provided that: no single height, width, or length dimension shape of the fume cupboard is greater than 2.5 times either of shall be such that the other two dimensions. test results are not affected. Before the test, the vertical velocity of the air through the fume cupboard shall be measured 100 mm in front of and behind the final position where the test apparatus will be located. It shall be E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 between 0.10 and 0.30 m/s in order to avoid possible discomfort, by combustion products, to the operator. It is possible to use a fume cupboard with a natural ventilation and an appropriate air velocity.
3.1.changed
Materials according to paragraph 6.2.3. of this Regulation: The samples dimensions are: are 560 mm x 170 mm. If the dimensions of a material do not permit taking a sample of the given dimensions the test shall be carried out, out taking a sample having the dimensions of at least 380 mm in accordance with height and at least 3 mm in width. Cable sleeves and cable conduits: The samples dimensions are: length: 560 mm, but at least 380 mm if the Technical Service, on the fitted size dimensions of a material do not permit taking a sample of the material which shall be mentioned in the test report. given dimensions; width: actual component dimension.
3.2.changed
Materials according to paragraph 6.2.3. of this Regulation: When the thickness of the sample is more than 13 mm, it shall be reduced to 13 mm by a mechanical process applied to the side which does not face the respective compartment (interior, engine or separate heating compartment). If it is impossible, the test shall be carried out in accordance with the Technical Service the initial thickness of the material, which shall be mentioned in the test report. Composite materials (see paragraph 6.1.3.) shall be tested as if they were of uniform construction. In the case of materials made of superimposed layers of different composition which are not composite materials, all the layers of material included within a depth of 13 mm from the surface facing towards the respective compartment shall be tested individually.
3.3.changed
The samples size of the sample shall be conditioned for at least 24 hours at a temperature of 23 °C + 2 °C and a relative humidity of 50 + 5 per cent and shall be maintained under these conditions until immediately prior to testing. mentioned in the test report.
3.4.added
The samples shall be conditioned for at least 24 hours at a temperature of
23 °C ± 2 °C and a relative humidity of 50 ± 5 per cent and shall be maintained
under these conditions until immediately prior to testing.
Figure 1deleted
4.2.changed
The burner shall be preheated for 2 minutes. The flame height shall be adjusted to 40 + ± 2 mm measured as the distance between the top of the burner tube and the tip of the yellow part of the flame when the burner is vertically oriented and the flame is viewed in dim light. Annex 8
4.4.changed
The marker threads shall be attached horizontally in front of and behind the specimen at the locations shown in Figure 1. At each location, a loop of thread shall be mounted so that the two segments are spaced 1 mm and 5 mm from the front and rearface of the specimen. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 8 Each loop shall be attached to a suitable timing device. Sufficient tension shall be imposed to the threads to maintain their position relative to the specimen.
5.changed
The observed phenomena shall be written down in the test-report, to include: (a) The durations of combustion: t1, t2 and t3 in seconds, and (b) The corresponding burnt distances: d1, d2 and d3 in mm. The burning rate V1 and the rates V2 and V3, if applicable, shall be calculated (for each sample if the flame reaches at least one of the first marker threads) as follows: Vi = 60 di/ti (mm/min) The highest burning rate of V1, V2 and V3 shall be taken into account. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
Figure 2changed
Figure 3changed
(Dimensions in millimetres) E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1
2.3.changed
The test liquid shall be diesel fuel according to standard EN 590:1999 (Market fuels). or alternatively diesel fuel according to UN Regulation No. 83 (Annex 10: Specification of reference fuels).
4.5.changed
Remove the test liquid and the test sample from the apparatus. If residue of the test liquid is found on the test sample it shall be removed without compressing the test sample. E/ECE/TRANS/505/ Rev.2/Add.117/Rev.1 Annex 9
Annex 10added
Test to determine the resistance to flame propagation of
electrical cables
1.added
This annex defines prescriptions to test the resistance to flame propagation of
electrical cables used in the vehicle.
3.1.added
Test samples shall have a length of at least 600 mm of insulation.
4.added
Determine the resistance to flame propagation using a Bunsen burner with an
appropriate gas, having a combustion tube of 9 mm internal diameter, where
the flame temperature at the tip of the inner blue cone shall be (950 +/- 50) °C.
Suspend the test sample in a draught-free chamber and expose the test sample
to the tip of the inner cone of the flame, as shown in Figure 1. The upper end
of the cable shall point away from the closest wall of the chamber. The sample
shall be subject to a stress, e.g. by means of a weight over a pulley, in order to
keep it straight at all times. The angle of the cable shall be 45° ± 1° relative to
the vertical line. In any case, the shortest distance of any part of the sample
shall be 100 mm minimum from any wall of the chamber. Apply the flame
with the tip of the inner blue cone touching the insulation (500 ± 5) mm from
the upper end of the insulation.
Figure 1added
Key
1 test sample
2 Bunsen burner