Skip to content

Compare versions of UN R149

Road illumination devices (lamps) and systems for power-driven vehicles

244 changed · 202 added · 240 deleted
1.changed
This Regulation applies to the following road illumination devices: devices (lamps): • Headlamps emitting a driving-beam and/or an asymmetrical passing-beam passing- beam for vehicles of categories L, M, N and T • Adaptive front-lighting systems (AFS) for vehicles of categories M and N • Adaptive Driving-Beam (ADB) for vehicles of category L3 • Headlamps emitting a driving-beam and/or a symmetrical passing-beam for vehicles of categories L and T • Front fog lamps for vehicles of categories L3, L4, L5, L7, M, N and T • Cornering lamps for vehicles of categories M, N and T 1 Agreement concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions for Reciprocal Recognition of Approvals Granted on the Basis of these United Nations Regulations (E/ECE/TRANS/505/Rev.3)
Introductiondeleted
This Regulation combines the provisions of the individual UN Regulations Nos. 19, 98, 112, 113, 119 and 123 into a single regulation, and is the outcome of the WP.29 decision to simplify the UN lighting and light-signalling regulations based on the initial proposal by the European Union and Japan. The objective of this Regulation is to increase the clarity, consolidate and streamline the complexity of requirements in UN Regulations Nos. 19, 98, 112, 113, 119 and 123 and prepare for the future transition to performance based requirements, by reducing the number of regulations through an editorial exercise without changing any of the detailed technical requirements already in force up to the date of entry into force of this Regulation. Although this Regulation departs from the traditional approach of having a separate regulation for each device, by combining all road illumination devices into a single regulation, this simplified regulation contains all provisions and operates according to the existing structure of series of amendments, their transitional provisions and supplements. The transitional provisions associated with a new series of amendments of this Regulation will be identified for each device as applicable, this also includes a list of devices and their applicable change indexes relating to the series of amendments. It is expected that all Contracting Parties to the 1958 Agreement will adopt this Regulation and shall provide detailed explanation in case they are no…
2.changed
For the purpose purposes of this Regulation:
2.1.changed
Nos. 48 in force at the time of application for type approval shall apply, unless otherwise specified. specified in this Regulation or in the pertinent installation UN Regulations Nos. 53, 74 and 86.
2.2.changed
"Road illumination devices (lamps) of different types" means road illumination devices which differ in such essential respects as:
2.2.1.changed
The trade name or mark: (a) Lamps Road illumination devices (lamps) bearing the same trade name or mark but produced by different manufacturers shall be considered as being of different types; (b) Lamps Road illumination devices (lamps) produced by the same manufacturer differing only by the trade name or mark shall be considered as being of the same type;
2.2.4.changed
Suitability The suitability for right-hand or left-hand traffic or for both traffic systems;
2.2.5.changed
For headlamps: the kind of beam produced (passing beam, driving beam (passing-beam, driving-beam or both);
2.2.6.changed
For AFS: the front-lighting function(s), function(s) produced (passing-beam, driving-beam and adaptive main-beam); the change of mode(s) and classes produced; and/or class(es) does not constitute a change of type;
2.2.7.changed
For AFS: The category of light source(s) used and/or the characteristic(s) light source module specific identification code(s); the use of the signal(s), specified for the system; LED substitute light source(s) does not constitute a change of type, however, paragraph 4.6.1. applies;
2.2.8.changed
The category However, a device intended for the installation on the left side of light source(s) used and/or the LED module specific identification code(s); vehicle and the corresponding device intended for the installation on the right side of the vehicle shall be considered to be of the same type.
2.3.added
“Main mode” means: - in case of a headlamp: principal passing-beam if present, otherwise front fog lamp if present, otherwise driving-beam; - in case of AFS: passing-beam mode which draws the highest total wattage.
2.2.9.deleted
However, a device intended for the installation on the left side of the vehicle and the corresponding device intended for the installation on the right side of the vehicle shall be considered to be of the same type.
3.1.2.1.changed
drawings, sufficiently detailed to permit identification of the type and, if applicable, of the class of the lamp, showing: (a) Geometrically in what position(s) the lamp(s) and/or the lighting units may be mounted on the vehicle in relation to ground and vehicle longitudinal median plane; (b) The axis of observation to be taken as the axis of reference in the tests (horizontal angle H = 0°, vertical angle V = 0°) or in the case of lighting units showing each of them in vertical (axial) section and in front elevation, with main details of the optical design including the axis/axes of reference; and the point to be taken as the centre of reference during the tests; (c) The limit of the apparent surface of the function(s); (d) The position space reserved and the arrangement intended for the approval mark marking or the “Unique Identifier”; Unique Identifier; (e) In case of LED replaceable light source module(s), the module(s) also and the space reserved for the specific identification code(s) of the module(s) on the lamp and on the module(s); (f) A frontal view, with details of lens ribbing if any, and the cross section and any optical features, of the lens, if applicable;
3.1.2.2.added
A brief technical description stating in particular: (a) In the case of lamps with replaceable UN approved light sources, the category or categories of light source(s) prescribed; (b) In the case of lamps with replaceable light source modules, the light source module specific identification code; (c) The make and type of electronic light source control gear(s), if any and if not being part of an installation unit; (d) In the case the lamp shall also be approved with the LED substitute light source(s) according to UN Regulation No. 128, the category or categories of light source(s) prescribed; (e) If the device (lamp) is equipped with an adjustable reflector, the mounting position(s) of the lamp in relation to the ground and the longitudinal median plane of the vehicle;
3.1.2.2.1.added
In the case of a headlamp, it shall specify: (a) Whether the headlamp is intended to provide both a passing-beam and a driving-beam or only one of these beams; (b) If the headlamp is intended to provide a passing-beam, whether it is designed for both left-hand and right-hand traffic or for either left-hand or right-hand traffic only; (c) To which Class(es) (passing-beam and/or driving-beam) the headlamp belongs; (d) In the case of light source module(s) this shall include: (i) A brief technical specification of the light source module(s); (ii) A drawing with dimensions and the basic electrical and photometric values and the objective luminous flux and for each light source module a statement whether it is replaceable or not; (iii) In case of electronic light source control gear, information on the electrical interface necessary for approval testing; (e) Whether the left and the right headlamps are operating as matched pair;
3.1.2.2.2.added
In the case of an AFS, it shall specify: (a) The lighting function(s) and their modes to be provided by the system; 1 (b) The lighting units contributing to each of them and the signals2 with the technical characteristics relevant to their operation; (c) Which categories of the bending mode requirements apply, if any; (d) Which additional data set(s) of Class E passing-beam provisions according to Table 12, if any; (e) Which set(s) of Class W passing-beam provisions according to paragraph 5.3.2., if any; (f) Which lighting units2 provide or contribute to one or more passing- beam cut-off(s); (g) The indication(s)2 according to the provisions of paragraph 5.3.5.1. with respect to paragraph 6.22. of UN Regulation No. 48; (h) Which lighting units are designed to provide the minimum passing- beam illumination according to paragraph 5.3.2.8.1.; (i) Mounting and operation requirements for test purposes; 1 To be indicated in a form conforming to the model of Annex 1. 2 To be indicated in a form conforming to the model of Annex 14. (j) Any other relevant information; (k) In the case of light source module(s) this shall include, for each module: (i) A brief technical specification of the light source module(s); (ii) A drawing with dimens…
3.1.3.1.deleted
In the case of a headlamp, it shall specify: (a) Whether the headlamp is intended to provide both a passing-beam and a driving-beam or only one of these beams; (b) If the headlamp is intended to provide a passing-beam, whether it is designed for both left-hand and right-hand traffic or for either left-hand or right-hand traffic only; (c) To which Class the headlamp belongs; (d) In the case of LED module(s) this shall include: (i) A brief technical specification of the LED module(s); (ii) A drawing with dimensions and the basic electrical and photometric values and the objective luminous flux and for each LED module a statement whether it is replaceable or not; (iii) In case of electronic light source control gear, information on the electrical interface necessary for approval testing;
3.1.2.2.3.added
In the case of adaptation of the driving-beam, which lighting units2 provide or contribute to the gradual adaptation of the driving-beam and of the sensor system along with the technical characteristics relevant to their operation.
3.1.3.2.deleted
In the case of an AFS, it shall specify: (a) The lighting function(s) and their modes to be provided by the system; 2 (b) The lighting units contributing to each of them1 and the signals3 with the technical characteristics relevant to their operation; 2 To be indicated in a form conforming to the model of Annex 1. 3 To be indicated in a form conforming to the model of Annex 14. (c) Which categories1 of the bending mode requirements apply, if any; (d) Which additional data set(s) of Class E passing-beam provisions according to Table 14 of paragraph 5.3.2., if any; (e) Which set(s) of Class W passing-beam provisions according to paragraph 5.3.2., if any; (f) Which lighting units2 provide or contribute to one or more passing- beam cut-off(s); (g) The indication(s)1 according to the provisions of paragraph 5.3.5.1. with respect to paragraph 6.22. of UN Regulation No. 48; (h) Which lighting units are designed to provide the minimum passing- beam illumination according to paragraph 5.3.2.8.1.; (i) Mounting and operation requirements for test purposes; (j) Any other relevant information; (k) In the case of LED module(s) this shall include: (i) A brief technical specification of the LED module(s); (ii) A drawing with dimensions and the basic electrical and photometric values and the objective luminous flux and for each LED module a statement whether it is rep…
3.1.2.2.3.1.added
The safety concept as laid down in the documentation, which, to the satisfaction of the Technical Service responsible for type approval tests: (a) Describe the measures designed into the system to ensure compliance with the provisions of paragraphs 4.11.1.2. and 5.3.2.5.4.; and (b) Indicates the instructions for their verification according to paragraph 5.3.2.6.; and/or (c) Gives access to the relevant documents demonstrating the system’s performance concerning sufficient reliability and safe operation of the measures specified according to paragraph 3.1.2.2.3.1. a), e.g. FMEA ("Failure Mode and Effect Analysis"), FTA ("Fault Tree Analysis") or any similar process appropriate to system safety considerations.
3.1.3.3.deleted
In the case of adaptation of the driving-beam, which lighting units2 provide or contribute to the gradual adaptation of the driving-beam and of the sensor system along with the technical characteristics relevant to their operation.
3.1.2.3.added
In the case of Driver Assistance Projection according to UN Regulation No. 48, it shall specify the size (horizontal and vertical angular limits) of the zone used for performing said projections.
3.1.3.3.1.deleted
The safety concept as laid down in the documentation, which, to the satisfaction of the Technical Service responsible for type approval tests: (a) Describe the measures designed into the system to ensure compliance with the provisions of paragraphs 4.11.2.1. and 5.3.2.5.4.; and (b) Indicates the instructions for their verification according to paragraph 5.3.2.6.; and/or (c) Gives access to the relevant documents demonstrating the system’s performance concerning sufficient reliability and safe operation of the measures specified according to paragraph 3.1.3.3.1. a), e.g. FMEA ("Failure Mode and Effect Analysis"), FTA ("Fault Tree Analysis") or any similar process appropriate to system safety considerations.
3.1.2.4.added
If not otherwise specified, two complete samples, one sample intended for the installation on the left side of the vehicle and one sample intended for the installation of the right side of the vehicle.
3.1.3.4.deleted
If not otherwise specified, two complete samples, one sample intended for the installation on the left side of the vehicle and one sample intended for the installation of the right side of the vehicle.
3.1.2.5.added
For all lamps with plastic outer lenses, except for cornering lamps, samples of the plastic material of which the lenses are made (see Annex 8).
3.1.3.5.deleted
For all lamps with plastic outer lenses, except for cornering lamps, samples of the plastic material of which the lenses are made (see Annex 8).
3.1.2.6.added
In the case of an AFS system, one set of samples of the system, for which approval is sought, including the mounting devices, supply and operating devices, and signal generators if any;
3.1.3.6.deleted
In the case of an AFS System, one set of samples of the system, for which approval is sought, including the mounting devices, supply and operating devices, and signal generators if any;
3.1.2.7.added
In the case of a type of lamp differing only by the trade name or mark from a type that has already been approved it is sufficient that the application is accompanied by:
3.1.3.7.deleted
In the case of a type of lamp differing only by the trade name or mark from a type that has already been approved it is sufficient that the application is accompanied by:
3.1.2.7.1.added
A declaration by the lamp manufacturer that the type submitted is identical (except in the trade name or mark) with and has been produced by the same manufacturer as the type already approved, the latter being identified by its approval number;
3.1.3.7.1.deleted
A declaration by the lamp manufacturer that the type submitted is identical (except in the trade name or mark) with and has been produced by the same manufacturer as the type already approved, the latter being identified by its approval number;
3.1.2.7.2.added
Two samples bearing the new trade name or mark or equivalent documentation.
3.1.3.7.2.deleted
Two samples bearing the new trade name or mark or equivalent documentation.
3.1.3.changed
A brief technical description stating in particular: (a) In the case of cornering lamps equipped with replaceable light sources, the category or categories of non-replaceable filament light source(s) prescribed; this or light source category(s) shall be one of those contained in UN Regulations Nos. 37, 99 or 128 (b) In the case of lamps with replaceable light source modules, the light source module specific identification code; (c) The make and type of supply and operating device(s), if any and if not being part of an installation unit; (d) If the device (lamp) is module(s) equipped with an adjustable reflector, non-replaceable filament light source(s), the mounting position(s) of the lamp in relation applicant shall annex to the ground and the longitudinal median plane of the vehicle; type approval documentation a report according to paragraph 4.5.2.5.
3.2.added
A separate approval is required for each lamp (function) listed in Table 1. When two or more lamps are part of the same assembly of grouped, combined or reciprocally incorporated lamps, approval is granted only if each of these lamps satisfies the requirements of this Regulation or of another Regulation. Lamps not satisfying any one of those Regulations shall not be part of such an assembly of grouped, combined or reciprocally incorporated lamps.
3.2.4.changed
If approval is sought for an AFS which is not intended to be included as part of the approval of a vehicle type according to UN Regulation No. 48, 48 or if approval is sought for an ADB for vehicles of category L3 which is not intended to be included as part of the approval of a vehicle type according to UN Regulation No. 53,
3.2.4.1.changed
The applicant shall submit sufficient documentation to prove the capability of the system to comply with the provisions of paragraph 6.22. of UN Regulation No. 48 or paragraph 6.16. of UN Regulation No. 53 when correctly installed, and
3.2.4.3.deleted
The symbols identifying the road illumination function for which type approval has been granted.
3.2.5.added
The symbols identifying the road illumination function for which type approval has been granted.
Table 1changed
Symbol if device is part Lamp (function) Symbol Driving beam of a matched pair Driving-beam headlamp of Class A R Passing beam YR Passing-beam headlamp of Class A V (asymmetrical) C Driving beam V YV Driving-beam headlamp of Class B HR Passing beam YHR Passing-beam headlamp of Class B C (asymmetrical) HC Driving beam headlamp C YC Auxiliary driving-beam of Class D (GDL) DR Passing beam headlamp of Class D (GDL asymmetrical) DC Lamp (function) Symbol RA RA - Adaptive Front lighting System (AFS): (Class AFS-C): basic passing passing-beam XC3 - Adaptive Front lighting System (Class AFS-E): motorway passing- - beam XC XCE3, 4 3 In the case of a single installation unit the symbol "XC" is marked only once. 4 In the case of more installation units each providing one or more AFS function(s) each unit is marked with the symbol "X" followed by the identification symbol(s) of the specific AFS function(s) provided. Symbol if device is part Lamp (function) Symbol of a matched pair Adaptive Front lighting System (Class AFS-V): town passing-beam XCV3, 4 - Adaptive Front lighting System (Class AFS-W): adverse weather - passing-beam XCW3, 4 Adaptive Front lighting System (AFS): motorway passing beam XCE5 Adaptive Front lighting System (AFS): town passing beam XCV4 Adaptive Front lighting System (AFS): adverse weather passing beam XCW4 Adaptive Front lighting System (AFS): driving beam XR4 Passing beam (Class AFS-R): driving-beam XR3 - Passing-beam headlamp of Class AS (symmetrical) C-AS Passing beam YC-AS Passing-beam headlamp of Class BS (symmetrical) C-BS Passing beam YC-BS Passing-beam headlamp of Class CS (symmetrical) WC-CS Passing beam YC-CS* Passing-beam headlamp of Class DS (symmetrical) WC-DS Passing beam headlamp of Class ES (GDL symmetrical) WC-ES Driving beam YC-DS* Driving-beam headlamp of Class BS R-BS Driving beam YR-BS* Secondary driving-beam headlamp of Class CS WR-CS Driving beam YR-CS* Secondary driving-beam headlamp of Class DS WR-DS Driving beam headlamp YR-DS* Adaptive driving-beam (ADB) for vehicles of Class ES (GDL) WR-ES category L3 ADB YADB Front fog lamp of Class F3 F3 YF3 Cornering lamp of Class K K - * The minimum value symbol “W” is not indicated because deemed unnecessary for “a” in these classes as part 1 of Annex 13 shall be at least 5 mm for front fog lamps and cornering lamps and, for all other devices, at least 5 mm in case of with plastic lenses and at least 8 mm in case of glass lenses. a matched pair
3.2.4.4.deleted
The applicable change indexes for each device relating to the series of amendments shall be as follows (see also paragraph 6.1.1.): 4 In the case of a single installation unit the symbol "XC" is marked only once. 5 In the case of more installation units each providing one or more AFS function(s) each unit is marked with the symbol "X" followed by the identification symbol(s) of the specific AFS function(s) provided.
3.2.6.added
The applicable change indexes for each device relating to the series of amendments shall be as follows (see also paragraph 6.1.1.):
Table 2changed
Series of amendments to the Regulation 00 01 Change Index for the Lamp (Function) specific Function (Lamp) function (lamp) Driving beam Lamp (Function) Driving-beam headlamp of Class A 0 Passing beam 1 Passing-beam headlamp of Class A (asymmetrical) 0 Driving beam - Passing-beam headlamp of Class V (asymmetrical) - 0 Driving-beam headlamp of Class B 0 Passing beam 1 Passing-beam headlamp of Class B (asymmetrical) 0 Driving beam - Passing-beam headlamp of Class C (asymmetrical) - 0 Auxiliary driving-beam of Class RA - 0 Adaptive driving-beam 0 1 Adaptive driving-beam (ADB) for vehicles of category L3 - 0 Driving-beam headlamp of Class D (GDL) 0 Passing beam - Passing-beam headlamp of Class D (GDL (GDL) 0 asymmetrical) - Adaptive Front lighting System (AFS): (Class AFS-C): basic 0 passing beam 1 passing-beam Adaptive Front lighting System (AFS): (Class AFS-E): motorway 0 passing beam 1 passing-beam Series of amendments to the Regulation 00 01 Change Index for the Lamp (Function) specific Lamp (Function) Adaptive Front lighting System (AFS): (Class AFS-V): town 0 passing beam 1 passing-beam Adaptive Front lighting System (AFS): (Class AFS-W): adverse 0 1 weather passing beam passing-beam Adaptive Front lighting System (AFS): driving (Class AFS-R): driving- 0 1 beam Passing beam Passing-beam headlamp of Class AS (symmetrical) 0 Passing beam 1 Passing-beam headlamp of Class BS (symmetrical) 0 Passing beam 1 Passing-beam headlamp of Class CS (symmetrical) 0 Passing beam 1 Passing-beam headlamp of Class DS (symmetrical) 0 Passing beam 1 Passing-beam headlamp of Class ES (GDL (symmetrical) 0 symmetrical) Driving beam - Driving-beam headlamp of Class BS 0 Driving beam 1 Secondary driving-beam headlamp of Class CS 0 Driving beam 1 Secondary driving-beam headlamp of Class DS 0 Driving beam 1 Driving-beam headlamp of Class ES (GDL) 0 - Front fog lamp of Class F3 0 1 Cornering lamp of Class K 0 1 Notes to Table 2: A dash “-” means that this lamp (function) is not available for type approvals according to the corresponding series of amendments.
3.3.1.1.changed
Every device belonging to an approved type shall comprise a space of sufficient size for the Unique Identifier (UI) as referred to in the 1958 Agreement and other markings as defined in paragraph 3.3.2.6. or, if technically not possible, 3.3.4. or the approval marking with the additional symbols and other markings as defined in paragraph 3.3.2. respectively. 3.3.4.
3.3.1.1.1.added
All markings shall be clearly legible and indelible.
3.3.1.3.deleted
The space for the UI or the approval mark shall be shown in the drawings mentioned in paragraph 3.1.2.
3.3.1.4.deleted
The UI or the approval mark with the additional symbols, shall be clearly legible and indelible. It may be placed on an inner or outer part (transparent or not) of the lamp which cannot be separated from the transparent part of the lamp emitting the light. In any case the marking shall be visible when the lamp is fitted on the vehicle or when a movable part such as the hood or boot lid or a door is opened.
3.3.1.2.1.added
The value for “a” in part 1 of Annex 13 shall be at least 5 mm on plastic material and at least 8 mm on glass.
3.3.1.5.deleted
UI or approval mark may be applied, provided that all the grouped, combined or reciprocally incorporated lamps satisfy the pertinent Regulation and that the following requirements are also fulfilled: (a) Requirements of paragraph 3.3.2. apply; (b) No part of the grouped, combined or reciprocally incorporated lamps that transmits light can be removed without at the same time removing the approval mark; (c) The symbols for each lamp, appropriate to each Regulation under which approval has been granted, shall be marked: (i) Either on the appropriate light-emitting surface; (ii) Or in a group, in such a way that each lamp of the grouped, combined or reciprocally incorporated lamps may be clearly identified; (d) The size of the components of a single approval mark shall not be less than the minimum size required for the smallest of the individual marks by the pertinent Regulation.
3.3.1.6.deleted
In the case of different types of lamps complying with the requirements of several Regulations, which use the same outer lens having the same or different colour, a single approval mark may be used provided that: (a) The symbols for each lamp, appropriate to each Regulation under which approval has been granted, are marked in conformity to paragraph 3.3.2.; (b) The main body of the lamp shall bear the approval mark of the actual function(s); (c) The size of the components of a single approval mark shall not be less than the minimum size required for the smallest of the individual marks by the pertinent Regulation.
3.3.2.1.changed
A The approval mark, i.e. a circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval.6 approval. 5
3.3.1.7.deleted
In the case of lamps grouped, combined or reciprocally incorporated with other lamps the lens of which may also be used for other types of lamps the provisions of paragraph 3.3. apply.
3.3.2.2.changed
The four to six-digit sequential number being part of the approval number prescribed in paragraph 3.2.2.
3.3.2.3.changed
The number of this Regulation followed by the letter 'R' and the two digits indicating the series of amendments in force at the time of issue of the approval. 5 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.6).
3.3.2.4.changed
Additional symbols for headlamps, AFS and front fog lamps: Symbol(s), according to Table 1, and, if applicable, the following additional symbol(s):
3.3.2.4.2.changed
In the case of headlamps/AFS installation unit designed to meet the requirements of both traffic systems by means of with or without an appropriate adjustment of the setting of the optical unit or the light source(s) or LED light source module(s), a horizontal arrow with a head on each end, the heads pointing respectively to the left and to the right;
3.3.2.4.4.changed
In the case of front fog lamps, headlamps and AFS installation unit road illumination devices incorporating a an outer lens of plastic material, the group of letters "PL" to be affixed near the symbols identifying the lighting; function(s);
3.3.2.4.5.changed
In the case of headlamps/AFS installation unit meeting the requirements of the driving-beam, an indication, placed near the circle surrounding the letter "E", of the maximum luminous intensity expressed by a reference mark (I' M), as defined in paragraph 5.1.3.6. 5.1.4.2. In the case of grouped or reciprocally incorporated driving-beam headlamps/AFS lighting unit, indication of the maximum luminous intensity of the driving-beams as a whole shall be expressed as above.
3.3.2.4.6.changed
In the case of headlamps/AFS AFS, a score above the letter(s) indicates that the AFS function(s) is(are) provided by more than one installation unit so designed on that side of the light source(s) or LED module(s) producing the principal passing-beam shall not be lit simultaneously with that of any other lighting function with which it may be reciprocally incorporated: an oblique stroke (/) shall be placed behind the symbol indicating the headlamp producing the passing beam in the approval mark. system.
3.3.2.4.7.changed
In the case of AFS, a score above in addition the letter(s) indicates that symbol “T”, after the AFS symbol(s) of all lighting function(s) is(are) provided by more than one installation unit on that side of and/or class(es) designed to comply with the system. respective bend lighting provisions, with said symbol(s) arranged together and leftmost to the symbol “T”.
3.3.2.5.changed
The approval number number, the symbols and the additional symbols shall be placed close to the circle and either above or below the letter “E”, or to the right or left of that letter. 6 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.6). The digits of the approval number shall be on the same side of the letter “E” and face the same direction.
3.3.2.4.6.1.deleted
This requirement shall not apply to headlamps meeting the requirements of Class D headlamps which are so designed that the passing beam and the driving beam are provided by the same gas-discharge light source.
3.3.3.1.added
The approval marking as defined in paragraph 3.3.2. may be replaced by the Unique Identifier, if available. The Unique Identifier mark shall follow the format in the example shown below: Figure I Unique Identifier (UI) The above Unique Identifier marked on the lamp shows that the type concerned has been approved and that the relevant information on that type approval can be accessed on the UN secure internet database by using 163210 as the Unique Identifier.
3.3.4.added
Road illumination functions or systems shall bear the approval marking or the Unique Identifier, the trade name or mark of the applicant and the following markings:
3.3.4.1.added
In the case of devices including a passing-beam designed to satisfy the requirements both of right-hand and of left-hand traffic, markings indicating the two settings of the optical unit on the vehicle or of the light source on the reflector; these markings shall consist of the letters "R/D" for the position for right-hand traffic and the letters "L/G" for the position for left-hand traffic;
3.3.2.6.deleted
Road illumination functions or systems shall bear, in indelible and clearly legible manner, the trade name or mark of the applicant and the following markings:
3.3.4.2.added
In the case of lamps with replaceable UN approved light source(s) or with replaceable light source modules, a marking indicating: (a) The category or categories of light source(s) prescribed; in the case where lamps have been approved for LED substitute light source(s), also the category or categories of the LED substitute light source(s); and/or (b) The specific identification code(s) of light source module(s) and (c) The rated voltage(s) (i.e. 6V, 12V or 24V) or the range of voltage.
3.3.2.6.1.deleted
In the case of devices including a passing beam designed to satisfy the requirements both of right-hand and of left-hand traffic, markings indicating the two settings of the optical unit on the vehicle or of the light source on the reflector; these markings shall consist of the letters "R/D" for the position for right-hand traffic and the letters "L/G" for the position for left-hand traffic;
3.3.4.3.added
In the case of lamps with non-replaceable light source modules a marking indicating the rated voltage(s) or the range of voltage;
3.3.2.6.2.deleted
In the case of lamps with replaceable light source(s) or with replaceable light source modules, a marking indicating: (a) The category or categories of light source(s) prescribed for headlamps of Classes AS, BS, CS, DS, ES and cornering lamps; and/or (b) The light source module specific identification code; and /or (c) The rated voltage(s), the rated wattage(s) and specific identification code of LED module(s) for headlamps, front fog lamps and AFS;
3.3.4.4.added
In the case of lamps with light source module(s), a marking on the light source module(s) indicating: (a) The trade name or mark of the applicant; (b) The specific identification code of the module. This specific identification code shall comprise the starting letters “MD” for “MODULE” followed by the markings as described in paragraphs
3.3.2.6.3.deleted
In the case of lamps with light source module(s), a marking on the light source module(s) indicating: (a) The trade name or mark of the applicant; (b) The specific identification code of the module. This specific identification code shall comprise the starting letters “MD” for “MODULE” followed by the approval mark without the circle as prescribed in paragraph 3.3.2.1.; this identification code shall be shown in the drawings mentioned in paragraph 3.1.2. The approval mark does not have to be the same as the one on the lamp in which the module is used, but both marks shall be from the same applicant; (c) In case of cornering lamps, the rated voltage or the range of voltage. In the case where the light-source module(s) is non-replaceable, it does not need to be marked.
3.3.2.1.added
(without the circle) and 3.3.2.2. and, in case several non- identical light source modules are used, followed by additional symbols or characters. This identification code shall be shown in the drawings mentioned in paragraph 3.1.2.1. The approval mark does not have to be the same as the one on the lamp in which the module is used, but both marks shall be from the same applicant; (c) The rated voltage or the range of voltage. In the case where the light-source module(s) is non-replaceable, it does not need to be marked;
3.3.2.6.4.deleted
In the case of cornering lamps with: (a) An electronic light source control gear; or (b) Non-replaceable light sources; and/or (c) Light source module(s); marking of the rated voltage or range of voltage;
3.3.4.5.added
In the case an electronic light source control gear, which is part of the lamp but not included into the lamp body, is used to operate a light source or a light source module(s), it shall be marked with its specific identification code and the rated input voltage or range of voltage;
3.3.2.6.5.deleted
On an electronic light source control gear:
3.3.4.6.added
In the case of AFS, front fog lamps and headlamps except Class AS, BS, CS, and DS meeting the requirements of Annex 7 only when supplied with a voltage of 12V, a marking consisting of the Number 24 crossed out by an oblique cross (X) near the holders of the light source(s) as shown in Annex 12;
3.3.2.6.5.1.deleted
In case of headlamps, AFS systems and front fog lamps: If an electronic light source control gear which is not part of a LED module is used to operate a LED module(s), it shall be marked with its specific identification code(s), the rated input voltage and wattage.
3.3.4.7.added
In the case of a headlamp having additional lighting unit(s) for vehicles of categories L and T:
3.3.2.6.5.2.deleted
In case of cornering lamps: An electronic light source control gear being part of the lamp but not included into the lamp body shall bear the name of the manufacturer and its identification number.
3.3.4.7.1.added
The headlamps producing the principal passing-beam shall bear specific identification code of the additional lighting unit(s) mentioned in paragraph
3.3.2.6.6.deleted
In the case of AFS, front fog lamps and headlamps except Class AS, BS, CS, DS and ES meeting the requirements of Annex 7 only when supplied with a voltage of 12V, a marking consisting of the Number 24 crossed out by an oblique cross (X) near the holders of the light source(s);
3.3.2.6.7.deleted
In the case of a headlamp having additional lighting unit(s) for vehicles of categories L and T:
3.3.4.7.2.added
Additional lighting unit(s) shall bear the trade name or mark of the applicant and the following markings:
3.3.2.6.7.1.deleted
The headlamps producing the principal passing beam shall bear specific identification code of the additional lighting unit(s) mentioned in paragraph
3.3.4.7.2.1.added
In the case of light source(s), their category(ies); in the case where the lamp has been approved for the use of LED substitute light source(s) in the additional lighting unit(s), also the category or categories of the LED substitute light source(s); and/or In the case of light source module(s), the rated voltage and rated wattage and the specific identification code(s) of the light source module(s).
3.3.4.7.2.2.added
The specific identification code(s) of the additional lighting unit(s). This marking shall be clearly legible and indelible. This specific identification code shall be comprised of starting letters "ALU" for "Additional Lighting Unit" followed by approval marking without the circle and in the case where several non-identical additional lighting units are used, additional symbols or characters shall follow. This specific identification code shall be shown in the drawings. The approval marking does not have to be the same as the one on the lamp in which the additional lighting unit(s) is used, but both markings shall be from the same applicant.
3.3.2.6.7.2.deleted
Additional lighting unit(s) shall bear the trade name or mark of the applicant and the following markings:
3.3.4.8.added
Road Illumination Devices may bear on their light-emitting surface a centre of reference as shown in Annex 11.
3.3.2.6.7.2.1.deleted
In the case of LED module(s), the rated voltage and rated wattage and the specific identification code(s) of the LED module(s).
3.3.2.6.7.2.2.deleted
The specific identification code(s) of the additional lighting unit(s). This marking shall be clearly legible and indelible. This specific identification code shall be comprised of starting letters "ALU" for "Additional Lighting Unit" followed by approval marking without the circle and in the case where several non-identical additional lighting units are used, additional symbols or characters shall follow. This specific identification code shall be shown in the drawings. The approval marking does not have to be the same as the one on the lamp in which the additional lighting unit(s) is used, but both markings shall be from the same applicant.
3.3.5.1.added
The Unique Identifier or the approval marking shall be placed on an inner or outer part (transparent or not) of the lamp.
3.3.3.deleted
The approval marking may be replaced by the Unique Identifier (UI), if available. The Unique Identifier mark shall follow the format in the example shown below: Figure I Unique Identifier (UI) The above Unique Identifier (UI) marked on the lamp shows that the type concerned has been approved and that the relevant information on that type approval can be accessed on the UN secure internet database by using 163210 as the Unique Identifier.
3.3.5.2.added
In any case, the Unique Identifier or the approval marking as well as the category or categories of LED substitute light source(s) prescribed, if any, shall be visible when the lamp is fitted on the vehicle or when a movable part such as the hood or boot lid or a door is opened.
3.3.5.3.added
If the outer lens of a device is designed to be separated from the main body, the Unique Identifier or the approval marking shall be placed on both, the detachable lens and the main body.
3.3.5.4.added
In case an outer lens is used for several devices and bearing different approval markings, the main body of each device shall bear only the approval marking of the function(s) of that device.
3.3.6.1.added
Unique Identifier or approval mark may be applied, provided that all the grouped, combined or reciprocally incorporated lamps satisfy the pertinent Regulation and that the following requirements are also fulfilled: (a) Requirements of paragraph 3.3.2. apply; (b) No part of the grouped, combined or reciprocally incorporated lamps that transmits light can be removed without at the same time removing the approval mark; (c) The symbols for each lamp, appropriate to each UN Regulation under which approval has been granted, shall be marked: (i) Either on the appropriate light-emitting surface; (ii) Or in a group, in such a way that each lamp of the grouped, combined or reciprocally incorporated lamps may be clearly identified.
3.5.1.deleted
Road illumination devices approved under this Regulation shall be so manufactured as to conform to the type approved by meeting the requirements set forth in paragraphs 4.16. and 5.
3.5.1.1.deleted
The minimum requirements for conformity of production control procedures set forth in Annex 2 shall be complied with;
3.5.1.2.deleted
The minimum requirements for sampling by an inspector set forth in Annex 3 shall be complied with;
3.5.2.deleted
The Type Approval Authority which has granted type approval may at any time verify the conformity control methods applied in each production facility. The normal frequency of these verifications shall be once every two years.
3.5.changed
The conformity of production procedures shall comply with those set out in the 1958 Agreement, Schedule 1 (E/ECE/TRANS/505/Rev.3), with the following requirements: requirements set forth in paragraph 6.
3.5.3.deleted
For devices in accordance with paragraph 5.6. only (Cornering Lamps) and in the case of non-replaceable filament light source(s) or light source module(s) equipped with non-replaceable filament light source(s), the applicant shall annex to the type approval documentation a report (by the light source manufacturer indicated in the type approval documentation), acceptable to the Authority responsible for type approval that demonstrates compliance of these non-replaceable filament light source with the requirements as specified in paragraph 4.11 of IEC 60809, Edition 3.
3.5.4.deleted
Road illumination devices with apparent defects are disregarded.
3.5.5.deleted
The reference mark is disregarded.
3.5.6.deleted
The measuring points in Table 8 Part B are disregarded.
3.5.7.deleted
The measuring points 8 to 15 in Table 35 are disregarded.
4.2.changed
Lamps shall be so made that they give adequate illumination without dazzle when emitting the passing-beam, and good illumination when emitting the driving-beam. Bend lighting may be produced by activating one additional filament light source, one or more additional LED light source(s), or one or more additional LED module(s) being part of a lamp producing a passing beam.
4.3.changed
Lamps shall be fitted with a device enabling them to be so adjusted on the vehicles as to comply with the rules applicable to them. In case of the headlamps of classes AS, BS, CS, DS and ES, such a device may or may not provide horizontal adjustment, provided that the headlamps are so designed that they can maintain a proper horizontal aiming even after the vertical aiming adjustment. Such a device need not be fitted on units in which the reflector and the diffusing lens cannot be separated, provided the use of such units is confined to vehicles on which the lamp setting can be adjusted by other means.
4.3.1.added
In case of headlamps of classes AS, BS, CS, DS and of front fog lamps, such a device may or may not provide horizontal adjustment, provided that the headlamps are so designed that they can maintain a proper horizontal aiming even after the vertical aiming adjustment.
4.3.2.added
In case of cornering lamps, such a device is not required.
4.4.changed
Where a lamp producing a principal passing-beam and a lamp producing a driving-beam, each equipped with its own light source(s) or LED light source module(s), are assembled to form one unit, the adjusting device shall enable the principal passing-beam and the driving- beam driving-beam to be adjusted individually. However, these provisions shall not apply to assemblies whose reflectors optical units are indivisible.
4.5.1.added
The lamp shall only be equipped with: - replaceable light source(s) approved according to UN Regulations Nos. 37, 99 and/or 128, provided that no restriction on the use is made at the time of application for type approval, and/or - light source module(s) and/or - non-replaceable light source(s).
4.5.2.2.changed
In case of replaceable UN approved light source(s), (a) The design of the lamp shall be such that the light source(s) can be fixed in no other position but the correct one; (b) The light source(s) holder shall conform to the characteristics given in IEC Publication 60061. The holder data sheet relevant to the category of light source(s) used, prescribed, applies. In addition, where a category of LED substitute light source(s) is also prescribed, the holder data sheet relevant to the category of LED substitute light source(s) applies.
4.5.1.1.deleted
The lamp shall only be equipped with light source(s) approved according to UN Regulations Nos. 37, 99 and/or 128, provided that no restriction on the use is made in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 99 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 128 and its series of amendments in force at the time of application for type approval, and/or LED module(s), and/or light source module(s) (for cornering lamps only) and/or non-replaceable light source(for cornering lamps only).
4.5.2.3.changed
Electronic light source control gear(s), if applicable, Road illumination devices shall be considered to be part not generate radiated or power line disturbances, which cause a malfunction of other electric/electronic systems of the lamp; they may be part of the LED module(s). vehicle.6
4.5.1.2.deleted
Front fog lamps, irrespective of whether the light sources can be replaced or not, shall only be equipped with one or more light sources approved according to: (a) UN Regulation No. 37, or (b) UN Regulation No. 99, or (c) UN Regulation No. 128, And/or, one or more LED modules where the requirements of Annex 9 shall apply; compliance with these requirements shall be tested.
4.5.2.4.changed
The headlamp In case of class D and/or class ES and its ballast system or replaceable light source control gear shall not generate radiated or power line disturbances, which cause a malfunction of other electric/electronic systems module(s), the design of the vehicle. 7 light source module(s) shall be such that (a) it can only be fitted in the designated and correct position and can only be removed with the use of tool(s); and (b) it is tamperproof; and (c) regardless of the use of tool(s), it is not mechanically interchangeable with: - any replaceable UN approved light source; and/or, - any other replaceable light source module having different characteristics that is located in the same lamp housing. (d) when the light source module is removed and replaced by another module provided by the applicant and bearing the same light source module identification code, the photometric requirements of the lamp or AFS system shall be met.
4.5.1.3.deleted
Headlamps of class D shall only be equipped with:
4.5.2.4.1.added
If applicable, light source modules shall comply with the requirements specified in Annex 9.
4.5.1.3.1.deleted
In case of the principal passing beam, one gas-discharge light source. A maximum of two additional light sources are permitted for the passing beam as follows: (a) One additional filament light source approved according to UN Regulation No. 37, one or more additional LED light source(s) approved according to UN Regulation No. 128 or one or more additional LED module(s) may be used inside the passing beam headlamp to contribute to bend lighting. (b) One additional filament light source approved according to UN Regulation No. 37, one or more additional LED light source(s) approved according to UN Regulation No. 128 and/or one or more LED module(s) inside the passing beam headlamp, may be used for the purposes of generating infrared radiation. It/they shall only be activated at the same time as the gas discharge light source. In the event that the gas-discharge light source fails, this additional filament light source, LED light source(s) and/or LED module(s) shall be automatically switched off. In the event of failure of an additional filament or LED light source or LED module, the headlamp shall continue to fulfil the requirements of the passing beam.
4.5.2.5.changed
Front fog lamps, designed In the case of lamps equipped with non-replaceable filament light source(s) or light source module(s) equipped with non-replaceable filament light source(s), the applicant shall annex to operate permanently the type approval documentation a report, acceptable to the Authority responsible for type approval, that demonstrates compliance of these non-replaceable filament light source(s) with an additional system to control the intensity requirements as specified in paragraph 4.11 of the light emitted, or which are reciprocally incorporated with another function, using a common light source, and designed to operate permanently with an additional system to control the intensity of the light emitted, are permitted. IEC 60809, Edition 4.
4.5.1.3.2.deleted
In case of the driving beam, one or more filament light sources approved according to UN Regulation No. 37, one or more gas-discharged light source approved according to UN Regulation No. 99, one or more LED light sources approved according to UN Regulation No. 128 and/or LED module(s). Where more than one light source is used to provide the driving beam, these light sources shall be operated simultaneously. It is also possible that a part of the driving beam produced by one of these light sources will be used exclusively for short time signals (flash to pass) as declared by the applicant. This shall be indicated in the relevant drawing and a remark shall be made in the communication form.
4.5.1.4.deleted
Headlamps of classes A and B shall only be equipped with:
4.5.3.1.changed
In case of cornering lamps equipped with light source module(s), the design The luminous flux of the light source module(s) source(s), or the luminous flux of the principal passing-beam, shall be such as: (a) That each light source module(s) can only be fitted determined according to the provisions in no other position than the designated and correct one and can only be removed with the use of tool(s); (b) If there are more than one light source module(s) used in the housing for a device, light source module(s) having different characteristics cannot be interchanged within the same lamp housing; (c) The light source module(s) shall be tamperproof; (d) A light source module(s) shall be so designed that regardless of the use of tool(s), it shall not be mechanically interchangeable with any replaceable approved light source. paragraph
4.5.1.4.1.deleted
In case of the principal passing beam, one filament light source approved according to UN Regulation No. 37, one or more LED light source(s) approved according to UN Regulation No. 128 or one or more LED module(s). Additional light sources are permitted for the passing beam as follows: (a) One additional filament light source approved according to UN Regulation No. 37, one or more additional LED light source(s) approved according to UN Regulation No. 128, or one or more additional LED module(s) may be used inside the passing beam headlamp to contribute to bend lighting; (b) One additional filament light source approved according to Regulation No. 37, one or more additional LED light source(s) approved according to UN Regulation No. 128 and/or one or more LED module(s), inside the passing beam headlamp, may be used for the purposes of generating infrared radiation. It/they shall only be activated at the same time as the principal passing beam. In the event that the principal light beam fails, this/these additional light source(s) and/or LED module(s) shall be automatically switched off. In the event of failure of an additional filament light source, one of more additional LED light source(s) or one or more additional LED module(s), the headlamp shall continue to fulfil the requirements of the passing beam.
4.5.1.4.2.deleted
In case of the driving beam, irrespective of the type of light source (LED module(s) or filament or LED light source(s)) used to produce the principal passing-beam, one or more filament light sources approved according to UN Regulation No. 37, one or more LED light source(s) approved according to UN Regulation No. 128 or one or more LED module(s).
4.5.3.2.changed
For headlamps, AFS In case of the principal passing-beam either: (a) the total objective luminous flux of all light sources (UN approved light sources, light source modules and front fog lamp equipped with LED non-replaceable light source(s) and/or LED module(s): 7 Compliance with sources) producing the requirements for electromagnetic compatibility is relevant to principle passing-beam shall be equal or greater than the vehicle type. minimum values shown in Table 3a
4.5.1.5.deleted
Headlamps of classes AS, BS, CS, DS shall only be equipped with:
Table 3aadded
Principle passing-beam classes Minimum luminous flux in lm V, C, AFS-C, DS 1.00∙103 AS 1.50∙102 BS 3.50∙102 CS 5.00∙102 or (b) the luminous flux in the principal passing-beam shall meet the requirements in zones I and II, as specified in Table 3b, when aimed according to paragraphs 3.2. (for classes V, C, AFS-C) and 3.3. (for all the other classes) in Annex 5. 6 Compliance with the requirements for electromagnetic compatibility is relevant to the vehicle type.
4.5.1.5.1.deleted
In case of the principal passing beam, one or two filament light sources approved according to UN Regulation No. 37, one or more LED light source(s) approved according to UN Regulation No. 128 and/or one or more LED module(s). In the case of the use of additional light source(s) and/or additional lighting unit(s) to provide bend lighting, only filament light sources approved according to UN Regulation No. 37, LED light sources approved according to UN Regulation No. 128 and/or LED modules(s) shall be used.
Table 3badded
Minimum values of the luminous flux in the principal passing-beam in Zones I and II Minimum luminous flux Beam classes Zone Forward field in field in lm V, C, AFS-C, I 30°L to 30°R and 15°D to1°U 4.00∙102 DS II 30°L to 30°R and 3.5°D to1°U 2.00∙102 AS I 30°L to 30°R and 15°D to1°U 6.0∙101 II 30°L to 30°R and 3.5°D to1°U 3.0∙101 BS I 30°L to 30°R and 15°D to1°U 1.40∙102 II 30°L to 30°R and 3.5°D to1°U 7.0∙101 CS I 30°L to 30°R and 15°D to1°U 2.00∙102 II 30°L to 30°R and 3.5°D to1°U 1.00∙102
4.5.1.5.2.deleted
In case of the driving beam, irrespective of the type of light source (LED module(s) or filament or LED light source(s)) used to produce the principal passing-beam, one or more filament light sources approved according to UN Regulation No. 37, one or more LED light sources approved according to UN Regulation No. 128 or one or more LED module(s).
4.5.3.3.changed
In case of headlamps of classes AS, BS, CS and DS, the reference principle passing-beam the total objective luminous flux at 13.2 V of each filament all light sources (UN approved light sources, light source for modules and non- replaceable light sources) producing the principal passing beam does not exceed 900 lm for classes AS and BS and 2,000 lm for classes CS and DS. principle passing-beam shall be equal or smaller than the maximum values shown in Table 4, if any.
4.5.1.6.deleted
Headlamps of class ES shall only be equipped with:
Table 4changed
Headlamps Class ES Passing beam minimum 2,000 lumen Principle passing-beam classes Maximum luminous flux in lm AS 9.00∙102 BS 1.00∙103 CS 2.00∙103
4.5.1.6.1.deleted
In case of the principal passing beam, one gas-discharge light source approved according to UN Regulation No. 99, one or more LED light source(s) approved according to UN Regulation No. 128 or one or more LED module(s). In the case of the use of additional light source(s) and/or additional lighting unit(s) to provide bend lighting, only filament light sources approved according to UN Regulation No. 37, LED light sources approved according to UN Regulation No. 128 and/or LED modules(s) shall be used.
4.5.3.4.added
Front fog lamps, designed to operate permanently with an additional system to control the intensity of the light emitted, or which are reciprocally incorporated with another function, using a common light source, and designed to operate permanently with an additional system to control the intensity of the light emitted, are permitted.
4.5.1.6.2.deleted
In case of the driving beam, irrespective of the type of light source (LED module(s) or gas-discharge or LED light source(s)) used to produce the principal passing-beam, one or more gas-discharged light sources approved according to UN Regulation No. 99, one or more LED light sources approved according to UN Regulation No. 128 or one or more LED module(s).
4.5.3.5.added
Except for AFS and cornering lamps, in case of a lamp incorporating one or more light source(s) or light source module(s) producing the principal passing- beam or the front fog beam and having a total objective luminous flux which exceeds 2.00∙103 lumens, a reference shall be made in the communication form in Annex 1.
4.5.1.7.deleted
Cornering lamps shall only be equipped with one or a combination of: (a) Filament light sources approved according to UN Regulation No. 37; (b) LED light sources approved according to UN Regulation No. 128; (c) LED module(s); (d) Light Source module(s); (e) Non-replaceable light source.
4.5.3.6.added
In case of an AFS incorporating light sources and/or light source module(s) producing the basic passing-beam and having a total objective luminous flux of the lighting units as indicated under item 9.2.3.(a) of the communication form which exceeds 2.00∙103 lumen per side, a reference shall be made in the communication form in Annex 1.
4.5.1.8.deleted
AFS of classes C, E, V, W, R shall only be equipped with one or a combination of: (a) Filament light sources approved according to UN Regulation No. 37; (b) Gas-discharge light sources approved according to UN Regulation No. 99; (c) LED light sources approved according to UN Regulation No. 128; (d) LED module(s). However, the class C (basic) passing beam shall be equipped only with replaceable light sources or replaceable or non-replaceable LED modules.
4.6.1.changed
In All measurements, photometric and colorimetric, shall be made with respect to the case following conditions (Particulars of replaceable filament light sources: the methods of measurement to be used are given in Annex 4):
4.6.1.1.changed
In the case of filament replaceable UN approved light sources operating directly under vehicle voltage system conditions: The lamp sources, all measurements shall be checked by means of colourless made using standard (étalon) filament light sources as specified in UN Regulation No. 37. During the testing of the lamp, except for cornering lamps, the power supply to the filament light source(s) shall be regulated so as to obtain the reference luminous flux at 13.2 V as indicated on the relevant data sheet of UN Regulation No. 37. During the testing of cornering lamps, the power supply to the filament light source(s) shall be regulated so as to obtain the reference luminous flux at 13.2 V or 13.5 V as indicated on the relevant data sheet of UN Regulation No. 37. However, if a filament light source of category H9 or H9B is used for the principal passing-beam, the applicant may choose the reference luminous flux at 12.2 V or 13.2 V as indicated in the relevant data sheet of UN Regulation No. 37 and a reference stating which voltage was chosen for type approval shall be made in item 9 in the communication form of Annex 1. R.E.5.
4.6.1.1.1.added
Additionally, in the case of replaceable UN approved light source(s) controlled by an electronic light source control gear or variable intensity control, the standard light source(s) shall have a luminous flux value that does not deviate more than 5 per cent from its reference/objective luminous flux value when test voltage is applied.
4.6.1.2.changed
In order to protect the standard (étalon) filament case of a lamp equipped with light source during the process of photometric measurement it is permissible to carry out the module(s) or non-replaceable light source(s), all measurements at a luminous flux that differs from the reference luminous flux at 13.2 V. If the Technical Service chooses to carry out measurements in such a manner, the luminous intensity shall be corrected by multiplying the measured value by the individual factor F lamp of the standard (étalon) filament light source in order to verify the compliance made with the photometric requirements where: F lamp = Φ reference / Φ test Φ reference is the reference luminous flux at 13,2 V as specified light source(s) present in the relevant data sheet of UN Regulation No. 37 Φ test is the actual luminous flux used for the measurement. However, where the reference luminous flux of 12.2 V as specified in the data sheet for the category H9 or H9B is chosen, this procedure is not permitted. lamp.
4.6.1.3.added
In case of a lamp (function) using light sources which are subject to more than one of the conditions prescribed in paragraph 4.6., the photometric measurements may be made separately, in accordance with each applicable condition(s) set forth in paragraph 4.6. All separate measurement results, if any, shall be added together. The test laboratory may require from the applicant samples allowing to supply the different light source(s) separately.
4.6.1.4.added
During photometric measurements, stray reflections shall be avoided by appropriate masking.
4.5.2.6.deleted
Except for AFS and cornering lamps, in case of a lamp incorporating one or more light source(s) or LED module(s) producing the principal passing-beam or the front fog beam and having a total objective luminous flux which exceeds 2,000 lumens, a reference shall be made in the communication form in Annex 1. In case of an AFS incorporating light sources and/or LED module(s) producing the basic passing beam and having a total objective luminous flux of the lighting units as indicated under item 9.3.2.3. of the communication form which exceeds 2,000 lumen per side, a reference shall be made in the communication form in Annex 1. The objective luminous flux of LED modules shall be measured as described in paragraph 5. of Annex 9.
4.6.1.5.added
In the case where a front fog lamp or a cornering lamp may be installed on the vehicle in more than one or in a field of different positions the photometric measurements shall be repeated for each position or for the extreme positions of the field of the reference axis specified by the manufacturer.
4.5.2.7.deleted
A LED module shall be: (a) Only removable from its device with the use of tools, unless it is stated in the communication sheet that the LED module is non-replaceable; and (b) So designed that regardless of the use of tool(s), it is not mechanically interchangeable with any replaceable approved light source.
4.6.1.6.added
In the case where the lamp shall also be approved with LED substitute light source(s), all measurements, photometric and colorimetric, shall be repeated using the LED substitute light source(s) prescribed.
4.6.2.added
Unless otherwise specified, the voltage supplied at the lamp shall be either 6.3 V (6 Volt-Systems), 13.2 V (12 Volt-Systems) or 28.0 V (24 Volt- Systems).
4.6.2.1.added
In case of a lamp and/or a light source module controlled by an electronic light source control gear, the lamp shall be operated as specified by the applicant. The test laboratory may require from the manufacturer the electronic light source control gear.
4.6.2.2.added
In case of a lamp not controlled by an electronic light source control gear:
4.5.3.2.1.deleted
Electronic light source control gear(s) associated with the operation of LED module(s), if applicable, shall be considered to be part of the lamp; they may be part of the LED module(s).
4.6.2.2.1.added
in case of light source module(s) or non-replaceable light source(s) the voltage supplied at the input terminals of the lamp shall be operated as specified by the applicant;
4.5.3.2.2.deleted
The lamp and the LED module(s) themselves shall comply with the relevant requirements specified in Annex 9 to this Regulation. The compliance with the requirements shall be tested.
4.6.2.2.2.added
in the case of replaceable UN approved light sources the light sources shall be operated at the reference/objective luminous flux or alternatively at a different luminous flux with a proportional correction on the measured luminous intensities.
4.5.3.2.3.deleted
In case of the headlamp of classes A, B, D and AFS, the total objective luminous flux of all LED light sources and/or LED modules producing the principal passing beam and measured as described in paragraph 5. of Annex 9 (LED modules only) shall be equal or greater than 1,000 lumens.
4.6.2.3.added
In case of lamps equipped with multiple replaceable UN approved light sources:
4.5.3.2.4.deleted
In case of the headlamp of classes AS, BS, CS and DS, the total objective luminous flux of all LED light sources and/or LED modules producing the principal passing beam and measured as described in paragraph 5. of Annex 9 (LED modules only) shall be within the following limits.
4.6.2.3.1.added
shall be operated at a voltage or electrical current setting such that the actual luminous fluxes of the light sources do not deviate by more than 5 per cent from the average luminous flux of the light sources. The measured luminous intensities shall be corrected proportionally for the difference between the average luminous flux and the applicable reference/objective luminous flux.
Table 3deleted
Headlamps Headlamps Headlamps Headlamps Class AS Class BS Class CS Class DS Passing beam 150 lumen 350 lumen 500 lumen 1,000 lumen minimum Passing beam 900 lumen 1,000 lumen 2,000 lumen 2,000 lumen maximum
4.6.2.3.2.added
alternatively, can be tested by using one light source in each of the individual lamp holder positions operating at the reference/objective luminous flux and application of the sum of the measured luminous intensities for each direction.
4.5.3.2.5.deleted
In case of headlamps of class ES, the total objective luminous flux of all LED light sources and/or LED modules producing the principal passing beam and measured as described in paragraph 5. of Annex 9 shall be within the following limits:
4.6.2.4.added
The identification of an electronic light source control gear if applicable and/or the voltage applied, including the tolerances, shall be noted in the communication form in Annex 1.
4.6.3.changed
In the case of replaceable LED light sources: The lamp shall be checked by means of a standard light source as specified in UN Regulation No. 128. During testing of the lamp, the voltage supplied to the light source(s) shall be regulated to maintain 13.2 V or 13.5 V (optionally Tests for cornering lamps only) for a 12 V system or 28 V for a 24 V system, or at the vehicle voltage as specified by the applicant, with a tolerance of ±0.1 V. The luminous intensity values produced shall be corrected. The correction factor is the ratio between the objective luminous flux and the value compliance of the luminous flux found at the voltage applied. In the case of more than one LED light source, the mean value of the correction factors intensities and colorimetric characteristics shall be applied, while each individual correction factor shall not deviate more than 5 per cent from this mean value. carried out according to Annex 10.
4.5.3.2.6.deleted
In the case of a replaceable LED module the removal and replacement of this LED module, as described in Annex 9, paragraph 1.4.1. shall be demonstrated to the satisfaction of the Technical Service.
4.6.3.1.added
For lamps (functions) using different light source technologies, the colorimetric characteristics shall be checked for each light source technology separately according to the applicable provisions in paragraphs 4.6.1. and
4.5.3.2.7.deleted
UN Regulation No. 48 defines that LED modules may contain holders for other light sources.
4.6.2.added
The test laboratory may require from the applicant samples allowing to supply the different light source(s) separately.
4.6.deleted
Depending on the light source used, the following conditions shall apply.
4.7.2.changed
The UV resistance of light transmitting components located inside a front fog lamp and made of plastic material shall be tested according to Annex 8, paragraph 3.4. 3.3.
4.8.changed
The sharpness and linearity of the cut-off, if applicable, shall be tested according to the requirements in Annex 5 or 6 respectively. 6.
4.6.2.deleted
In the case of a gas-discharge light source: A standard light source shall be used as specified in UN Regulation No. 99, which has been aged during at least 15 cycles, in accordance with paragraph 4. of Annex 4 to UN Regulation No. 99. During testing of the lamp the voltage at the terminals of the ballast or at the terminals of the light source in case the ballast is integrated with the light source shall be regulated to maintain 13.2 V for a 12 V system, or at the vehicle voltage as specified by the applicant, with a tolerance of ±0.1 V. The objective luminous flux of the gas-discharge light source may differ from that specified in UN Regulation No. 99. In this case, the luminous intensity values shall be corrected accordingly.
4.10.changed
Lamps Passing-beam headlamps and AFS with asymmetrical "cut-off" line designed to satisfy the requirements both of right hand and of left hand left-hand traffic may be adapted for traffic on a given side of the road either by an appropriate initial setting when fitted on the vehicle or by selective setting by the user. Such initial or selective setting may consist, for example, of fixing either the optical unit at a given angle on the vehicle or the light source(s) producing the principal passing-beam at a given angle/position in relation to the optical unit. In all cases, only two different and clearly distinct settings, one for right hand and one for left-hand traffic, shall be possible, and the design shall preclude inadvertent shifting from one setting to the other or setting in an intermediate position. Where two different setting positions are provided for the light source(s) producing the principal passing-beam, the components for attaching this light source(s) to the reflector must be so designed and made so that, in each of its two settings, this light source(s) will be held in position with the precision required for headlamps designed for traffic on only one side of the road. Conformity with the requirements of this paragraph shall be verified by visual inspection and, where necessary, by a test fitting.
4.6.4.deleted
In the case of LED modules: All measurements on lamps equipped with LED module(s) shall be made at 6.3 V, 13.2 V or 28.0 V respectively, if not otherwise specified within this Regulation. LED modules operated by an electronic light source control gear shall be measured with the input voltage as specified by the applicant or with a supply and operating device which replace this control gear for the photometric test.
4.6.5.deleted
In the case of non-replaceable light sources, only, if allowed according to the requirements of paragraph 4: All measurements on lamps equipped with non-replaceable light sources shall be made at 6.3 V or 6.75 V (optionally for cornering lamps only), 13.2 V or 13.5 V (optionally for cornering lamps only) or 28.0 V or at other vehicle voltage as specified by the applicant. The test laboratory may require from the applicant the special power supply needed to supply the light sources. The test voltages shall be applied to the input terminals of the lamp.
4.11.1.changed
On headlamps or a system AFS designed to provide alternately a driving-beam and a passing-beam, or a passing-beam and/or a driving-beam designed to become bend lighting, any mechanical, electromechanical or other device incorporated in the headlamp and lighting unit(s) for these purposes shall be so constructed that:
4.6.6.deleted
In the case of a lamp that uses a light source control gear being part of the lamp, the voltage declared by the applicant shall be applied to the input terminals of that lamp.
4.6.7.deleted
In the case of a lamp that uses a light source control gear not being part of the lamp the voltage declared by the applicant shall be applied to the input terminals of that light source control gear. The test laboratory shall require from the applicant the special light source control gear needed to supply the light source and the applicable functions. The identification of that light source control gear if applicable and/or the voltage applied, including the tolerances, shall be noted in the communication form in Annex 1.
4.11.1.2.added
In the case of failure, the luminous intensity above the line H-H shall not exceed the values of a passing-beam according to paragraph 5.2.; in addition, on headlamps designed to provide a passing and/or a driving-beam to become a bend lighting, a minimum luminous intensity of at least 2.50∙103 cd. shall be fulfilled in test point 25V (V-V line, 1.72°D).
4.6.8.deleted
In the case of headlamps or AFS equipped with different kinds of light sources, the part of the lamp equipped: (a) With replaceable filament light sources shall be tested according to paragraph 4.6.1.; (b) With a gas-discharge light source shall be tested according to paragraph 4.6.2.; (c) With replaceable LED light sources shall be tested according to paragraph 4.6.3.; (d) With LED modules shall be tested according to paragraph 4.6.4. and then added to the previous result obtained from the light sources tested.
4.11.1.3.added
Either the principal passing-beam or the driving-beam shall always be obtained without any possibility of the mechanism stopping in between two positions.
4.11.2.1.changed
In Except for additional light source(s) and additional lighting unit(s) used to produce bend lighting, in the case of failure, the luminous intensity above the line H-H shall not exceed the values of failure it must be possible to obtain automatically a passing-beam according or a state with respect to paragraph 5.2.; the photometric conditions which yields values not exceeding 1.20∙103 cd in addition, on headlamps designed to provide a passing and/or a driving-beam to become a bend lighting, a minimum luminous intensity of Zone 1 and at least 2,500 cd. shall be fulfilled in test point 25 V (VV line, 1.72D). 2.40∙103 cd at 0.86D-V by such means as e.g. switching off, dimming, aiming downwards, and/or functional substitution;
4.11.2.2.changed
Either Except for additional light source(s) and additional lighting unit(s) used to produce bend lighting, either the principal passing-beam or the driving-beam shall always be obtained without any possibility of the mechanism stopping in between the two positions; positions.
4.11.3.1.changed
Except for additional light source(s) and additional lighting unit(s) used to produce bend lighting, in the case of failure it adaptation of the driving-beam, either the passing-beam or the driving-beam shall always be obtained, without any possibility of remaining in an intermediate or undefined state; if this is not possible, such a state must be possible covered by the provisions according to obtain automatically a passing beam or a state with respect to the photometric conditions which yields values not exceeding 1,200 cd in Zone 1 and at least 2400 cd at 0,86D-V by such means as e.g. switching off, dimming, aiming downwards, and/or functional substitution; paragraph 4.11.3.2.;
4.11.3.2.changed
Except for additional light source(s) and additional lighting unit(s) used In the case of failure, it must be possible to produce bend lighting, either the passing obtain automatically a passing- beam or a state with respect to the driving beam photometric conditions which yields values not exceeding 1.30∙103 cd in the zone III b as defined in paragraph 5.3. and at least 3.40∙103 cd in a point of "segment Imax", by such means as e.g. switching off, dimming, aiming downwards, and/or functional substitution; When performing the tests to verify compliance with these requirements, the Technical Service responsible for approval tests shall always be obtained without any possibility of refer to the mechanism stopping in between instructions supplied by the two positions; applicant.
4.11.4.changed
AFS: The user cannot, with ordinary tools, change the shape or position of the moving parts, or influence the switching device.
4.12.changed
Illumination configuration of lamps with asymmetrical "cut-off" line only for different traffic conditions conditions.
4.12.1.changed
In the case of lamps designed to meet the requirements of traffic moving on one side of the road (either right or left) only, appropriate measures shall be taken to prevent discomfort to road-users in a country where traffic moves on the side of the road opposite to that of the country for which the headlamp was designed8.Such designed7. Such measures may be: (a) Occulting a part of the outer lens area; (b) Downward movement of the beam. Horizontal movement is allowed; 8 Instructions on the installation of lamps fitted with the measures are given in UN Regulation No. 48. (c) Any other measure to remove or reduce the asymmetrical part of the beam.
4.11.2.deleted
Headlamps of classes A, B and D:
4.12.2.1.changed
Passing-beam designed for right-hand traffic and adapted to left-hand traffic: at 0.86D-1.72L 0.86°D - 1.72°L at least 2,500 2.50∙103 cd; 7 Instructions on the installation of lamps fitted with the measures are given in UN Regulation No. 48. at 0.57U-3.43R 0.57°U - 3.43°R not more than 880 8.80∙102 cd.
4.12.2.2.changed
Passing-beam designed for left-hand traffic and adapted to right-hand traffic: at 0.86D-1.72R 0.86° D -1.72°R at least 2,500 2.50∙103 cd; at 0.57U-3.43L 0.57°U - 3.43°L not more than 880 8.80∙102 cd.
4.13.changed
If applicable, the lamp shall be so made that that, if a light source and/or a LED module has failed, a failure signal in order to comply with the relevant provisions of UN Regulation No. 48 or UN Regulation No. 53 is provided.
4.11.3.deleted
Headlamps of classes AS, BS, CS, DS and ES:
4.15.changed
For photometric adjustment and measuring conditions, see Annex 4. 4.15.1 In the case of lamps with replaceable light sources, the lamp shall be considered acceptable if it meets the requirements of paragraph 5. with at least one standard (étalon) light source, which may be submitted with the lamp.
4.15.1.added
In the case of lamps with replaceable light sources, the lamp shall be considered acceptable if it meets the requirements of paragraph 5. with at least one standard (étalon) light source, which may be submitted with the lamp.
4.16.changed
Colour of light emitted: The colour of the light emitted shall be white for all lamps. However, for front fog lamps the colour of the light emitted may be selective yellow if requested by the applicant. For cornering lamps the colour of the light emitted inside the field of the light distribution grid defined in Annex 4, Figure A4-XII shall be white. Outside this field, no sharp variation of colours shall be observed.
4.11.4.1.deleted
Except in the case of adaptation of the driving-beam, either the passing-beam or the driving-beam shall always be obtained, without any possibility of remaining in an intermediate or undefined state; if this is not possible, such a state must be covered by the provisions according to paragraph 4.11.4.2.;
4.17.changed
In the case of headlamps or AFS with adjustable reflector the requirements of paragraphs 5.1. to 5.4. are applicable for each mounting position indicated according to paragraph 3.1.3. 3.1.2.2. For verification the following procedure shall be used:
4.11.4.2.deleted
In the case of failure it must be possible to obtain automatically a passing-beam or a state with respect to the photometric conditions which yields values not exceeding 1,300 cd in the zone III b as defined in paragraph 5.3 and at least 3,400 cd in a point of "segment Imax", by such means as e.g. switching off, dimming, aiming downwards, and/or functional substitution; When performing the tests to verify compliance with these requirements, the Technical Service responsible for approval tests shall refer to the instructions supplied by the applicant.
4.17.1.changed
Each applied position is realized on the test goniometer with respect to a line joining the centre of the light source and point HV on a an aiming screen. The adjustable reflector/system or part(s) thereof is then moved into such a position that the light pattern on the screen corresponds to the relevant aiming prescriptions;
4.11.5.deleted
The user cannot, with ordinary tools, change the shape or position of the moving parts, or influence the switching device.
4.17.3.changed
Additional tests shall be made after the reflector/system or part(s) thereof has been moved vertically ±2° or at least into the maximum position, if less than 2°, from its initial position by means of the headlamps/systems or part(s) thereof adjusting device. Having re-aimed the headlamp/system or part(s) thereof as a whole (by means of the goniometer for example) in the corresponding opposite direction the light output in the following directions shall be controlled and lie within the required limits: passing-beam: for headlamp points B50L and 75 R 75R (B50R and 75 L, 75L, respectively); for AFS points B50L and 75R, or 50R if applicable; for class AS, BS, CS, CS and DS, and ES, points HV and 0.86D- V; 0.86D-V; driving-beam: IM Imax and point HV (percentage of IM). Imax).
4.18.added
A matched pair is allowed for: - passing-beams of class C, V, AS, BS, CS or DS, - driving-beams of class A, B, BS, CS, DS or ADB, - front fog lamps.
4.19.added
For any road illumination devices listed in paragraph 1, in order to verify the visibility of white light towards the rear of a vehicle required in UN Regulation No. 48, the applicant may request a test, to show that in the angular field from 165° to 180° outboard in horizontal direction and -2.5° to +5° in vertical direction, the maximum luminous intensity is not more than 2.5∙10-1 cd. This additional test may be conducted taking into account the influence of the vehicle body.
5.1.changed
Technical requirements concerning driving-beam of the Class A, B, D (GDL), RA, ADB, BS, CS, CS or DS or ES (GDL) (symbols “R”, "HR", “DR”, "XR”, "R-BS”, “WR- CS”, “WR-DS” “HR”, “RA”, “XR”, “ADB”, “R-BS”, “WR-CS” or “WR-ES”) “WR-DS”)
5.1.1.changed
In the case of a road illumination device designed to provide a driving-beam and a passing-beam, measurements of the luminous intensity of the driving- beam The headlamp shall be taken with aimed according to Annex 5, paragraph 3.1. including the same alignment as for measurements under paragraphs 5.2. to 5.4. In the case allowed specific tolerances of a road illumination device providing a driving-beam only, it shall be so adjusted that the area of maximum luminous intensity is centred on the point of intersection of lines H-H and V-V; such a device needs to meet only the requirements referred to in paragraph 5.1.3. 4. For devices where more than one light source is used to provide the driving- beam, these light sources shall be operated simultaneously to determine the maximum value of the luminous intensity (IM). It is also possible that a part of the driving beam produced by one of these light sources will be used exclusively for short time signals "flash to pass" as declared by the applicant. This shall be indicated in the relevant drawing and a remark shall be made in the communication form. (Imax).
5.1.2.changed
Irrespective It is also possible that a part of the type driving-beam produced by one of light source used to produce the principal passing- beam, several these light sources are allowed to will be used exclusively for each individual driving- beam. short time signals "flash to pass" as declared by the applicant. This shall be indicated in the relevant drawing and a remark shall be made in the communication form.
5.1.3.changed
Requirements For the coordinates of any measuring point/line/zone a 0.25 tolerance is allowed independently at each test point for the luminous intensity distribution of the driving-beams: photometry unless indicated otherwise.
5.1.4.added
A4-II, A4-III or A4-IV, shall meet the requirements of Table 5.
4.16.1.deleted
The colorimetric characteristics of the lamps incorporating LED modules shall be measured according to paragraph 4.3.2. of Annex 9.
Table 5changed
Angular coordinates Minimum luminous intensity in cd in deg. Element Class RA Class CS Class DS vertical horizontal Class A Headlamp Class B Headlamp Class D Headlamp Angular Required luminous Required luminous Required luminous Test coordinates intensity intensity intensity BS (Auxiliary) (Secondary) (Secondary) 2U-V 2°U 0° 1.00∙103 1.70∙103 - - 1.00∙103 1.70∙103 H-12L 0° 12°L 6.00∙102 1.50∙103 - - - - H-9L 0° 9°L 2.00∙103 3.40∙103 - - - - H-6L 0° 6°L 3.40∙103 5.00∙103 - 2.50∙103 3.40∙103 5.00∙103 H-3L 0° 3°L 1.20∙104 1.75∙104 - 9.00∙103 1.20∙104 1.75∙104 H-V a 0° 0° 0.8×Imax 0.8×Imax 0.8×Imax 1.60∙104 2.00∙104 3.00∙104 H-3R 0° 3°R 1.20∙104 1.75∙104 - 9.00∙103 1.20∙104 1.75∙104 H-6R 0° 6°R 3.40∙103 5.00∙103 - 2.50∙103 3.40∙103 5.00∙103 H-9R 0° 9°R 2.00∙103 3.40∙103 - - - - H-12R 0° 12°R 6.00∙102 1.50∙103 - - - - Imax - - 2.70∙104 4.00∙104 1.00∙104 2.00∙104 2.70∙104 4.00∙104 Notes: In Table 5 a In case of a matched pair, the contribution of each lamp on H-V point Degrees cd cd cd Min Min Min IM 27,000 40,500 43,800 H-5L 0.0, 5.0 L 3,400 5,100 6,250 H-2.5L 0.0, 2.5 L 13,500 20,300 25,000 H-2.5R 0.0, 2.5 R 13,500 20,300 25,000 H-5R 0.0, 5.0 R 3,400 5,100 6,250 shall not be less than 40 per cent of the relevant beam class minimum Imax required.
5.1.4.1.added
H-H and V-V shall be situated within the isocandela 80 per cent of maximum luminous intensity (Imax)
5.1.4.2.added
The maximum value (Imax) shall not exceed 2.15∙105 cd in any direction.
5.1.4.2.1.added
The reference mark (I′M) of the maximum luminous intensity shall be obtained by the ratio: I′M = Imax /4,300 This value shall be rounded off to the value 2.5 - 5 - 7.5 - 10 - 12.5 - 17.5 - 20 - 25 - 27.5 - 30 - 37.5 - 40 - 45 - 50.
5.2.changed
Technical requirements concerning headlamps to provide a passing-beam of the Class A, B C and D (GDL) V (symbols “C”, “HC” “C” and “DC”) “V”)
4.17.4.deleted
If the applicant has indicated more than one mounting position, the procedure of paragraphs 4.17.1. to 4.17.3. shall be repeated for all other positions;
5.2.1.changed
The headlamp shall be aimed according to Annex 5, paragraph 1.2. 3.2. including the allowed specific tolerances of paragraph 4. If, however, vertical adjustment cannot be performed repeatedly to the required position within the allowed tolerances, the instrumental method of Annex 5, 6, paragraph 2. shall be applied to test compliance with the required minimum quality of the asymmetric "cut-off" line and to perform the beam vertical adjustment.
4.17.5.deleted
If the applicant has not asked for special mounting positions, the headlamp/system or part(s) thereof shall be aimed for measurements of paragraphs 5.1. to 5.4. with the relevant adjusting device(s) in its mean position. The additional test of paragraph 4.17.3. shall be made with the reflector/system or part(s) thereof moved into its extreme positions (instead of ±2°) by means of the relevant adjusting device(s).
5.2.1.1.changed
When so aimed, the headlamp shall: (i) If its approval is sought solely for provision of a passing-beam9, passing-beam8, comply with the requirements set out in paragraph 5.2.2.; (ii) If it is intended to provide both a passing-beam and a driving-beam, comply with the requirements set out in paragraphs 5.2.2. and 5.1.
5.2.2.changed
The passing-beam shall meet the luminous intensities at the test points referred to in Table 8 6 and in Figures A4-V or A4-VI. Passing-beam headlamps with gas-discharge light sources shall meet these luminous intensities only after more than 10 minutes after ignition. Figure A4-V.
Table 6changed
Required luminous beam (indicated for right-hand traffic) Luminous intensity [cd] Test Test point in cd Angular coordinates in deg. Element Class C Class V vertical horizontal min max min max Zone III As specified in part C - 6.25∙102 - 6.25∙102 S50+S50LL+S50RR As specified in part B 1.90∙102 b - - - S100+S100LL+S100RR As specified in part B 3.75∙102 b - - - BR 1°U 2.5°R 1.75∙103 1.75∙103 Segment BLL 0.57°U 8°L to 20°L 6.25∙102 - 6.25∙102 B50L 0.57°U 3.43°L 3.50∙102 3.50∙102 P 0° 7°L 6.3∙101 6.3∙101 75 R 0.57°D 1.15°R 1.21∙104 - - - 50 L 0.86°D 3.43°L 5.00∙103 a 3.70∙104 3.55∙103 a 3.70∙104 Part A 50 V 0.86°D 0° 5.10∙103 a - 5.10∙103 - 50 R 0.86°D 1.72°R 1.01∙104 - 5.10∙103 - Segment 50 0.86°D 6.84°L to 6.84°R 2.54∙103 - 1.80∙103 - Segment 40LL 1.07°D 14°L to 9°L 8.50∙102 - 6.00∙102 - 40L 1.07°D 9°L 2.80∙103 - 1.95∙103 - 40R 1.07°D 9°R 2.80∙103 - 1.95∙103 - Segment 40RR 1.07°D 9°R to 14°R 8.50∙102 - 6.00∙102 - 25V 1.72°D 0° 2.50∙103 - 1.75∙103 - Segment 25L 1.72°D 16°L to 9°L 1.18∙103 - 8.25∙102 - Segment 25 1.72°D 9°L to 9°R 1.70∙103 - 1.20∙103 - Segment 25R 1.72°D 9°R to 16°R 1.18∙103 - 8.25∙102 - Segment 15 2.86°D 20°L to 20°R 4.25∙102 - 3.00∙102 - Segment 10 4°D 4.5°L to 2°R 5.00∙102 3.50∙102 8 Such a special "passing-beam" headlamp may incorporate a driving beam not subject to requirements. 0,8 x the 0,8 x the actual actual Segment 10 and below 4°D 4.5°L to 2°R measured measured value at 50R value at 25V Imax - - 4.41∙104 Overhead sign requirements, angular point position of measurement points Element S50LL S50 S50RR S100LL S100 S100RR Part B Angular coordinates - Class BS Class CS Class DS, ES number degrees* MIN MAX MIN MAX MIN MAX 1 H-V 16,000 --- 20,000 --- 30,000 --- H-2.5°R in deg. vertical 4°U 4°U 4°U 2°U 2°U 2°U horizontal 8°L 0° 8°R 4°L 0° 4°R Zone III (bounded by the following coordinates) Angular coordinates in deg. Part C vertical 1°U 4°U 4°U 2°U 1.5°U 1.5°U 0° 0° horizontal 8°L 8°L 8°R 8°R 6°R 1.5°R 0° 4°L Notes: In Table 6, Part A, B and 2 9,000 --- 10,000 --- 20,000 --- 2.5°L 3 H-5°R and 5°L 2,500 --- 3,500 --- 5,000 --- 4 H-9°R and 9°L --- --- 2000 --- 3,400 --- 5 H-12°R and 12°L --- --- 600 --- 1,000 --- 6 2°U-V --- --- 1000 --- 1,700 --- MIN luminous intensity C: a In case of a matched pair the contribution of each lamp shall not be less than 50% of the 20,000 --- 25,000 --- 40,000 --- maximum (IM) MAX luminous intensity required minimum value. b One pair of position lamps, being incorporated with the headlamp or being intended to be installed together with the headlamp may be activated according to the indications of the --- 215,000 --- 215,000 --- 215,000 maximum (IM) * 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. applicant.
5.2.3.changed
There shall be no lateral variations detrimental to good visibility in any of the zones I, III and IV. zone III..
5.2.4.changed
Headlamps designed to meet the requirements of both right-hand and left-hand traffic shall, in each of the two setting positions of the optical unit, light source(s) or LED light source module(s) producing the principal passing-beam, meet the requirements set forth above for the corresponding direction of traffic.
5.2.5.changed
The requirements in paragraph 5.2.2. shall also apply to headlamps designed to provide bend lighting and/or that include the additional light source(s) or LED light source module(s) referred to in paragraph 5.2.6.2. In the case of a headlamp designed to provide bend lighting its alignment may be changed, provided that the axis of the beam is not displaced vertically by more than 0.2°. 5.2.6.
5.1.3.1.deleted
Referring to Figure A4-II the luminous intensity distribution of the driving- beam shall meet the following requirements.
5.2.5.1.1.changed
Swivelling the passing-beam or moving horizontally the kink of the elbow of the cut-off, the measurements shall be carried out after the complete headlamp assembly has been reaimed re-aimed horizontally, e.g. by means of a goniometer;
5.1.3.2.deleted
Referring to Figure A4-III the luminous intensity distribution of a primary driving-beam shall meet the following requirements.
5.2.5.1.3.changed
Means of additional light source(s) or LED light source module(s) without moving horizontally the kink of the elbow of the cut-off, measurements shall be carried out with this/these light source(s) or LED light source module(s) activated.
5.1.3.3.deleted
Referring to Figure A4-IV the luminous intensity distribution of a secondary driving-beam shall meet the following requirements.
5.2.6.changed
LED light source(s) or one or more LED module(s) are permitted for the principal passing-beam. Additional UN approved light sources or LED modules are permitted only as follows: and/or additional light source module(s) may be used inside the passing-beam headlamp to contribute to bend lighting;
5.2.7.added
Additional UN approved light sources and/or additional light source module(s), inside the passing-beam headlamp, may be used for the purposes of generating infrared radiation. It/they shall only be activated at the same time as the principal light source(s) or light source module(s). In the event that (one of) the principal light source(s) or (one of) the principal light source module(s) fails, this (these) additional light source(s) and/or light source module(s) shall be automatically switched OFF;
5.1.3.4.deleted
Except for classes BS, CS, DS and ES, the point of intersection (HV) of lines h h and v v shall be situated within the isocandela 80 per cent of maximum luminous intensity (Imax)
5.2.8.added
In the event of failure of one or more additional light source(s), or one or more additional light source module(s) as described in paragraphs 5.2.6. and 5.2.7., the headlamp shall continue to fulfil the requirements of the passing-beam.
5.1.3.5.deleted
The maximum value (IM) shall in no circumstances exceed 215,000 cd.
5.3.changed
Technical requirements concerning adaptive front-lighting systems (AFS) and concerning adaptive driving-beam (ADB) for vehicles of category L3 (symbols “XC”, “XCE”, “XCV”, “XCW” “XCW”, “XR” and “XR”) “ADB”)
5.1.3.6.deleted
The reference mark (I′M) of the maximum luminous intensity shall be obtained by the ratio: I′M = IM /4,300 This value shall be rounded off to the value 5 - 7.5 - 10 - 12.5 - 17.5 - 20 - 25 - 27.5 - 30 - 37.5 - 40 - 45 - 50.
5.3.1.1.changed
Each system shall provide a Class C passing-beam according to paragraph 5.3.2.4. and one or more passing-beam(s) of additional class(es); it may incorporate one or more additional modes within each class of passing- beam and the front-lighting functions according to paragraph 5.3.3. and/or 3.1.3.2.l.
5.3.1.1.1.added
Notwithstanding paragraph 5.3.1.1., ADB for vehicles of category L3 shall only comply with the requirements set out in paragraph 5.3.3. and its subparagraphs.
5.2.1.2.deleted
Where a headlamp so aimed does not meet the requirements set out in paragraphs 5.2.2. and 5.1., its alignment may be changed according to the provisions in Annex 5, paragraph 1.2.3. 9 Such a special "passing beam" headlamp may incorporate a driving beam not subject to requirements.
5.2.6.1.deleted
One additional filament light source according to UN Regulation No. 37, one or more additional LED light source(s) according to UN Regulation No. 128 or one or more additional LED module(s) may be used inside the passing-beam headlamp to contribute to bend lighting;
5.3.2.2.changed
The system or part(s) thereof shall be aimed according to the requirements of paragraph 1. of Annex 5 paragraph 3.2. including the allowed specific tolerances of paragraph 4 so that the position of the cut-off complies with the requirements indicated in the Table 10. If, however, vertical adjustment cannot be performed repeatedly to the required position within the allowed tolerances, the instrumental method of Annex 5, paragraph 2. shall be applied to test compliance with the required minimum quality of the "cut-off" line and to perform the beam vertical adjustment.
5.2.6.2.deleted
One additional filament light source according to UN Regulation No. 37, one or more additional LED light source(s) according to UN Regulation No. 128 and/or one or more LED module(s), inside the passing-beam headlamp, may be used for the purposes of generating infrared radiation. It/they shall only be activated at the same time as the principal light source or LED module(s). In the event that the principal light source or (one of) the principal LED module(s) fails, this additional light source and/or LED module(s) shall be automatically switched off;
Table 8changed
Headlamps for RH traffic***, Passing beam If, however, vertical adjustment cannot be performed repeatedly to the required position within the allowed tolerances, the instrumental method of Class A Class B Class D See beam pattern in Annex 4 Figure A4-V Figure A4-V Figure A4-VI Position in degrees horizontal vertical No. Element at/from to at min max min max min max 1 B50L 3.43 L 0.57 U 350 350 350 2 BR 2.50 R 1.00 U 1,750 1,750 3 Zone III (see Part C) 625 625 625 4 50R 1.72 R 0.86 D 5,100 10,100 12,500 5 75R 1.15 R 0.57 D 5,100 10,100 12,500 6 50V V 0.86 D 5,100 7,500 7 50L 3.43 L 0.86 D 3,550 13,200* 6,800 13,200* 18,480 8 75L 3.43 L 0.57 D 10,600 10,600 9 25L1 3.43L 1.72 D 18,800 10 25L2 9.00 L 1.72 D 1,250 1,700 2,500 11 25R1 9.00 R 1.72 D 1,250 1,700 2,500 Part A 12 25L3 15.00 L 1.72 D 1,250 13 25R2 15.00 R 1.72 D 1,250 14 15L 20.00 L 2.86 D 625 15 15R 20.00 R 2.86 D 625 Segment I A to B 5.15 L 5.15 R 0.86 D 3,750 Segment I C to D 2.50 R 1.00 U 1,750 Segment III and under 9.37 L 8.50 R 4.29 D 12,500 Zone IV 5.15 L to 5.15 R – 1,700 2,500 0.86D to 1.72D Zone I 9.00 L to 9.00 R – 17,600 < 2I** 1.72 D to 4.00 D Emax R Vertical above 1.72D, 43,800 right of V-V line Emax L Left of V-V line 31,300 Headlamps for RH traffic*** Test point Angular coordinates Degrees Required luminous intensity in cd B1 4.00 U – 8.00 L Points B1+B2+B3 B2 4.00 U – 0 190 min. B3 4.00 U – 8.00 R Part B B4 2.00 U – 4.00 L Points B4+B5+B6 B5 2.00 U – 0 375 min. B6 2.00 U – 4.00 R B7 0 – 8.00 L 65 min. B8 0 – 4.00 L 125 min. Zone III (bounded by the following coordinates in degree) 8.00 L 8.00 L 8.00 R 8.00 R 6.00 R 1.50 R V-V 4.00 L Part C 1.00 U 4.00 U 4.00 U 2.00 U 1.50 U 1.50 U H-H H-H Notes: In the Table 8, Part A, B and C: Letter L means that the point is located on the left of VV line. Letter R means that the point is located on the right of VV line. Letter U means the point is located above HH line. Letter D means the point or segment is located below HH line. * In case where a headlamp in which LED modules are producing a passing-beam in conjunction with an electronic light source control gear, the measured value shall not be more than 18,500 cd. ** Actual measured value at points 50R / 50L respectively. *** For left-hand traffic, the letter R 6, paragraph 2. shall be replaced by letter L applied to test compliance with the required minimum quality of the asymmetric "cut-off" line and vice versa. to perform the beam vertical adjustment.
5.2.6.3.deleted
In the event of failure of an additional filament light source, one or more additional LED light source(s) or one or more additional LED module(s), the headlamp shall continue to fulfil the requirements of the passing-beam.
5.3.2.3.changed
When so aimed, the system or part(s) thereof, (a) If its approval is sought solely for provision of the passing-beam, needs to comply with the requirements set out in the relevant paragraphs below; paragraphs; (b) If it is intended to provide additional lighting or light signalling functions according to the scope of this Regulation, it shall comply in addition with the requirements set out in the relevant paragraphs below, paragraphs, if not being adjustable independently.
5.3.2.4.changed
When emitting a specified mode of the passing-beam, the system shall meet the requirements in the respective section (C, V, E, W) of part A of Table 9 7 (photometric values) and in Table 10 8 (Imax and "cut-off" positions), as well as paragraph 1 ("cut-off" requirements) 2.1. (asymmetric "cut-off" definition) of Annex 5.
5.3.2.5.1.changed
The system meets the respective requirements of part B of Table 9 7 (photometric values) and item B of Table 10 8 ("cut-off" provisions), when measured according to the procedure indicated in paragraph 5.3.4., relevant to the category (either category 1 or category 2) of the bending mode, for which approval is sought;
5.3.2.5.2.changed
When the T-signal corresponds to the vehicle's smallest turn radius to the left (or right), the sum of the luminous intensity values provided by all contributors of the right or the left side of the system shall be at least 2,500 2.50∙103 cd at one or more points in the zone extending from H-H to 2 degrees 2° below H-H and from 10 10° to 45 degrees 45° left (or right). right);
5.3.2.5.4.changed
If approval is sought for a category 1 bending mode, the system is designed so that, in the case of a failure affecting the lateral movement or modification of the illumination, it must be possible to obtain automatically either photometric conditions corresponding to paragraph 5.3.2.4. or a state with respect to the photometric conditions which yields values not exceeding 1,300 1.30∙103 cd in the zone IIIb, as defined in Table 11, 9, and at least 3,400 3.40∙103 cd in a point of "segment I max"; Imax"; However, this is not needed if, for positions relative to the system reference axis up to 5 degrees left, 5°L, at 0.3 degree up 0.3°U from H-H, and greater than 5 degrees left, 5°L, at 0.57 degree up, 0.57°U, a value of 880 8.80∙102 cd is in no case exceeded.
5.3.2.6.changed
The system shall be checked on the basis of the relevant instructions of the manufacturer, indicated in the safety concept according to paragraph 3.1.3.3.1.
5.3.1.4.4.deleted
In case of a headlamp using a gas-discharge light source with the ballast not integrated with the light source, four seconds after ignition of a headlamp that has not been operated for 30 minutes or more:
5.3.1.4.4.1.deleted
At least 37,500 cd shall be attained at point HV, for a system producing driving-beam only.
5.3.2.8.1.changed
Any specified passing-beam mode provides at least 2,500 2.50∙103 cd at point 50V from each side of the system; The mode(s) of the Class V passing-beam are exempted from this requirement;
5.3.1.4.4.2.deleted
At least 3,100 cd shall be attained at point 50 V when the Class C passing- beam is activated, for systems producing passing-beam only or alternately producing passing-beam and driving-beam functions as described in paragraphs 4.11.1. and 4.11.4.
5.3.2.8.2.changed
Other modes: When signal inputs according to paragraph 5.3.1.5.3. 5.3.1.4.2. apply, the requirements of the paragraph 5.3.2. shall be fulfilled.
5.3.1.4.4.3.deleted
In either case the power supply shall be sufficient to secure the required rise of the high current pulse.
Table 7changed
Required in conjunction with Figure A4-VI (indicated for right-hand traffic) Angular coordinates in Luminous intensity in cd deg. Element Class C Class V Class E Class W b vertical horizontal min max min max min max min max Zone III As specified in Table 9 - 6.25∙102 - 6.25∙102 - 8.80∙102 - 8.80∙102 S50+S50LL+S50RR As specified in Table 11 1.90∙102 d - - - 1.90∙102 d - 1.90∙102 d - S100+S100LL+S100RR As specified in Table 11 3.75∙102 d - - - 3.75∙102 d - 3.75∙102 d - BR 1°U 2.5°R - 1.75∙103 1.75∙103 - 1.75∙10 3 - 2.65∙103 Segment BLL 0.57°U 20°L to 8°L - 6.25∙102 - 6.25∙102 - 8.80∙102 - 8.80∙102 B50L 0.57°U 3.43°L - 3.50∙102 -- 3.50∙102 - 6.25∙102 e - 6.25∙102 P 0° 7°L 6.3∙101 - 6.3∙101 - - - - - 125R 0.34°D 1.15°R - - - - 1.20∙104 - - - 75R 0.57°D 1.15°R 1.21∙104 - - - 1.52∙104 - 1.52∙104 - 50L 0.86°D 3.43°L 5.00∙103 f 3.70∙104 3.55∙103 f 3.70∙104 6.80∙103 f - 6.80∙103 f 3.70∙104 50V 0.86°D 0° 5.10∙103 f - 5.10∙103 - 1.01∙10 4a - 1.01∙104 a - 50R 0.86°D 1.72°R 1.01∙104 - 5.10∙103 - - - - 6.84°L to 2.54∙103 1.80∙103 2.54∙103 2.54∙103 Part A Segment 50 0.86°D - - - - 6.84°R Segment 40LL 1.07°D 14°L to 9°L 8.50∙102 - 6.00∙102 - 8.50∙10 2 - 8.50∙102 - 40L 1.07°D 9°L 2.80∙103 - 1.95∙103 - 2.80∙103 - 2.80∙103 - 40R 1.07°D 9°R 2.80∙103 - 1.95∙103 - 2.80∙103 - 2.80∙103 - Segment 40RR 1.07°D 9°R to 14°R 8.50∙102 - 6.00∙102 - 8.50∙102 - 8.50∙102 - 25V 1.72°D 0° 2.50∙103 - 1.75∙103 - 2.50∙103 - - - Segment 25L 1.72°D 16°L to 9°L 1.18∙103 - 8.25∙102 - 1.18∙103 - 1.18∙103 - Segment 25 1.72°D 9°L to 9°R 1.70∙103 - 1.20∙103 - 1.70∙103 - - - Segment 25R 1.72°D 9°R to 16°R 1.18∙103 - 8.25∙102 - 1.18∙103 - 1.18∙103 - Segment 20 and below 2°D 3.5°L to 0° - - - - - - - 1.76∙104 b Segment 15 2.86°D 20°L to 20°R 4.25∙102 - 3.00∙102 - 4.25∙102 - - - Segment 10 4°D 4.5°L to 2°R 5.00∙102 - 3.50∙102 - 5.00∙102 - - - 0.8 x the 0.8 x the 0.8 x the actual actual actual Segment 10 and below 4°D 4.5°L to 2°R measured - measured - measured - 7.10∙103 value at value at value at 50R 25V 50R Imax c - - - - 4.41∙104 - - - - Part B (bending mode): Table 7 applies, however the requirements for point B50L, Zone III and point 50L are indicated hereunder: Angular coordinates in deg. Luminous intensity in cd Element Class C Class V Class E Class Wb vertical horizontal Part B min max min max min max min max Zone III As specified in Table 9 - 8.80∙102 - 8.80∙102 - 8.80∙102 - 8.80∙102 B50L 0.57°U 3.43°L - 5.30∙10 2 - 5.30∙10 2 - - - 7.90∙102 50L 0.86°D 3.43°L 1.70∙103 - 1.70∙103 - 3.40∙103 - 3.40∙103 - Notes: In Table 7, Part A and B: a The contribution of each side of the system shall not be less than 2.50∙103 cd. b Requirements according to the provisions indicated in Table 10 apply in addition. c Position requirements according to the provisions of Table 8 ("Segment I max"). d One pair of position lamps, being incorporated with the system or being intended to be installed together with the system may be activated according to the indications of the applicant. e Requirements according to the provisions indicated in Table 12 apply in addition. f The contribution of each side of the system shall not be less than 50% of the required minimum value. Passing-beam elements angular position/extend, additional requirements (indicated for right-hand traffic) Angular coordinates in deg. Beam part designation and requirement vertical horizontal Angular position / extend for segment Imax 0.3 ° D 0.5 ° L A to to The maximum luminous intensity [cd] Test point in "Segment Imax" as indicated in 1.72°D 3°R this Table shall be within the limits as prescribed in “Imax” in Table 7. For Class BS Class CS Classes DS, ES Test point number angular coordinates C passing-beams the "cut-off" and part(s) of shall: B (a) comply with the requirements of paragraph 1. of Annex 5 and (b) be positioned with its "flat horizontal part" at 0.57°D - degrees* MIN MAX MIN MAX MIN MAX 1 H-V 16,000 --- 20,000 --- 30,000 --- 2 H-2.5°R and 2.5°L 9,000 --- 10,000 --- 20,000 --- 3 H-5°R and 5°L 2,500 --- 3,500 --- 5,000 --- 6 2°U-V --- --- 1,000 --- 1,700 --- MIN luminous intensity of the 20,000 --- 25,000 --- 40,000 --- maximum (IM) MAX luminous intensity of the --- 215,000 --- 215,000 --- 215,000 maximum (IM) * 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise.
Table 9changed
Position / (indicated for right-hand traffic) Angular coordinates in deg. Passing beam Tabled requirements expressed in cd horizontal Element Corner point No. 1 2 3 4 5 6 7 8 Zone III a vertical 1°U 4°U 4°U 2°U 1.5°U 1.5°U 0° 0° for Class C or Class V Passing-beam horizontal 8°L 8°L 8°R 8°R 6°R 1.5°R 0° 4°L Zone III b vertical 1°U 4°U 4°U 2°U 1.5°U 1.5°U 0.34°U 0.34°U for Class W or Class E Class W No. Element At/from to at min max min max min max min max 1 B50L L 3.43 - U 0.57 504 350 50 350 50 6257 50 625 3 BR R 2.50 - U 1.00 50 1 750 50 880 50 1 750 50 2 650 4 Segment BRR R 8.00 R 20 U 0.57 504 3 550 - 880 - 3 550 - 5 300 5 Segment BLL L 8.00 L 20 U 0.57 504 625 - 880 - 880 - 880 6 P L 7.00 - H 63 - - - - - 63 - 7 Zone III As specified in Table 11 - 625 - 625 - 880 - 880 8a S50+S50LL+S50RR5 - - U 4.00 1906 - - - 1906 - 1906 - 5 6 6 9a S100+S100LL+S100RR - - U 2.00 375 - - - 375 - 3756 - Part A 10 50 R R 1.72 - D 0.86 - - 5 100 - - - - 11 75 R R 1.15 - D 0.57 10 100 - - - 15 200 - 20 300 - 12 50 V V - D 0.86 5 100 - 5 100 - 10 100 - 10 100 - 13 50 L L 3.43 - D 0.86 3 550 13 2008 3 550 13 2008 6 800 - 6 800 26 4008 14 25 LL L 16.00 - D 1.72 1 180 - 845 - 1 180 - 3 400 - 15 25 RR R 11.00 - D 1.72 1 180 - 845 - 1 180 - 3 400 - 16 Segment 20 and below L 3.50 V D 2.00 - - - - - - - 17 6002 17 Segment 10 and below L 4.50 R 2.00 D 4.00 - 12 3001 - 12 3001 - 12 3001 - 7 1002 18 Imax - - - 16 900 44 100 8 400 44 100 16 900 79 300 29 530 70 5002 Part B (bending mode): Table 9 applies, however with the lines Nos. 1,7,13 and 18 being replaced by those listed hereunder 1 B50L L 3.43 - U 0.57 504 530 50 350 50 625 50 625 Part B 7 Zone III As specified in Table 11 - 880 - 880 - 880 - 880 13 50 L L 3.43 - D 0.86 1 700 - 1 700 - 3 400 - 3 400 - 18 Imax - - - 10 100 44 100 5 100 44 100 10 100 79 3007 20 300 70 5002 Notes: In the Table 9, Part A and B: 1 Max 15 900 cd, if the system is designed to provide also a Class W passing-beam. 2 Requirements according to the provisions indicated in Table 12 apply in addition. 3 Position requirements according to the provisions of Table 10 ("Segment Imax"). 4 The contribution of each side of the system (for segment BLL and BRR: of at least one point), when measured according to the provisions of Annex 4 shall not be less than 50 cd. 5 Position requirements according to the provisions of Table 13. 6 One pair of position lamps, being incorporated with the system or being intended to be installed together with the system may be activated according to the indications of the applicant. 7 Requirements according to the provisions indicated in Table 14 apply in addition. 8 The max. value may be multiplied by 1.4, if it is guaranteed according to the manufacturer's description that this value will not be exceeded in use, either by means of the system or, if the system's use is confined to vehicles, providing a corresponding stabilization/limitation of the system's supply, as indicated in the communication form. Passing-beam horizontal 8°L 8°L 8°R 8°R 6°R 1.5°R 0.5°L 4°L
Table 10changed
Class C passing- Class V passing- Class E passing- Class W passing- beam beam beam beam Beam part designation and requirement Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. (indicated for right-hand traffic) Angular position / extend coordinates in degrees for segment Imax 0.5 L 0.3 D 0.3 D 0.5 L 0.1 D 0.5 L 0.3 D The maximum deg. Max. luminous intensity Element vertical horizontal in A cd E 10°U 20°L to 20°R F1 10°L 1.75∙102 F2 10°U to to to to to to "Segment Imax" as indicated in this Table 3R 1.72D 1.72D 3R 1.72D 3R 1.72D shall be within the limits as prescribed in B The "cut-off" and part(s) of shall: (a) comply with the requirements of paragraph 1. of Annex 5 and (b) be positioned with its "flat horizontal part" not above not above not above at V = 0.57D 0.23D1 0.23D 0.57 D not below not below not below 1.3D 0.57D 0.57D Note to Table 10: 1 Requirements according to the provisions indicated in Table 9 apply in addition. 60°U 0° F3 10°R
Table 11changed
(indicated for right-hand traffic) Element S50LL S50 S50RR S100LL S100 S100RR Angular position coordinates in degrees Corner point No. 1 2 3 4 5 6 7 8 Zone III a deg. vertical 4°U 4°U 4°U 2°U 2°U 2°U horizontal 8L 8L 8R 8R 6R 1.5 R V-V 4L for Class C or Class V Passing Beam vertical 1U 4U 4U 2U 1.5 U 1.5 U H-H H-H Zone III b horizontal 8L 8L 8R 8R 6R 1.5 R 0.5 L 4L for Class W or Class E Passing Beam vertical 1U 4U 4U 2U 1.5 U 1.5 U 0.34 U 0.34 U 8°L 0° 8°R 4°L 0° 4°R
Table 12changed
Definition and requirements (indicated for segments E, F1, F2, and F3 (not shown right-hand traffic) Part A of Table 7 applies, however the requirement for point B50L is replaced as indicated hereunder: Angular coordinates in Table 9 and Figure A4-VII of Annex 4). Not more than 175 deg. Max. luminous intensity Data Set in cd is allowed: a) on a segment E extending at U 10 deg from L 20 to R 20 deg and b) on three vertical segments F1, F2 and F3 at horizontal positions L10 degrees, V and R 10 degrees, each extending from U 10 to U 60 degrees. Alternative/ Additional set of requirements for I max, segment 20 and segment 10: by those indicated hereunder. If, according to the applicants specification according to paragraph 3.1.3.2.(e) a Class W passing-beam is designed to produce on segment 20 and below it not more than 8,800 cd and on segment 10 and below it not more than 3,550 cd, the design value for Imax of that beam shall not exceed 88,100 cd. E1 5.30∙102 E2 0.57°U 3.43°L 4.40∙102 E3 3.50∙102
5.3.3.2.changed
When measured according to the provisions laid down in paragraph 5.1. the luminous intensity shall meet the requirements of Class B in Table 5 and of paragraph 5.1.3.4. 5.1.4.2.
5.1.4.2.added
with each lighting unit measured according to the relevant procedure indicated in paragraph 5.3.4.
5.3.3.4.changed
The system shall be so made that: that the lighting unit(s) of the right side and of the left side each provide at least 1.62∙104 cd at the point HV. In case of ADB for vehicles of category L3, each installation unit(s) shall provide at least 1.62∙104 cd at the point HV.
5.3.3.5.changed
If the specified beam requirements are not met, a re-aiming of the beam position within 0.5 degree up or down and/or 1 degree to the right or left, with respect to its initial aiming specific tolerances of Annex 5, paragraph 4, is allowed; in the revised position all photometric requirements shall be met. These provisions do not apply to lighting units as indicated under paragraph 5.3.3.1.1.
5.3.3.7.changed
During adaptation, the driving-beam function shall meet the requirements for all the cases of right-hand and left-hand traffic specified in Part A of Table 15. 13. These requirements shall be verified during the type approval testing in conjunction with a signal generator to be provided by the applicant. This signal generator shall reproduce the signals provided by the vehicle and cause the adaptation of the driving-beam and in particular shall represent the settings so that the photometric compliance can be verified.
5.3.3.7.1.changed
If the driving-beam function meets the requirements in Part A of Table 15 13 specified for line 1 to line 3 for oncoming and preceding vehicles (symmetrical beam) the relevant information shall be noticed in the communication document in Annex 1.
Table 13changed
Point designation S50LL S50 S50RR S100LL S100 S100RR Type approval photometric requirements concerning the adaptation of the driving-beam Angular position coordinates in degrees 4U/8L deg. Max. luminous Element vertical horizontal intensity b in cd Line 1 Left Oncoming vehicle at 50 m in 0.57°U 4.8°L to 2°L 6.25∙102 the case of right-hand traffic Line 1 Right Oncoming vehicle at 50 m in 0.57°U 2°R to 4.8°R 6.25∙102 the case of left-hand traffic Line 2 Left Oncoming vehicle at 100 m in 0.3°U 2.4°L to 1°L 1.75∙103 the case of right-hand traffic Line 2 Right Oncoming vehicle at 100 m in 0.3°U 1°R to 2.4°R 1.75∙103 the case of left-hand traffic Line 3 Left Oncoming vehicle at 200 m in 0.15°U 1.2°L to 0.5°L 5.45∙103 the case of right-hand traffic Part A Line 3 Right Oncoming vehicle at 200 m in 0.15°U 0.5°R to 1.2°R 5.45∙103 the case of left-hand traffic Line 4 U / V-V 4U/8R 2U/4L 2 U / V-V 0U/4R 1.7°L to 1°R 1.85∙103 Preceding vehicle at 50 m in the case of right-hand traffic > 1°R to 1.7°R 2.50∙103 0.3°U Line 4 1.7°R to 1°L 1.85∙103 Preceding vehicle at 50 m in the case of left-hand traffic > 1°L to 1.7°L 2.50∙103 Line 5 0.9°L to 0.5°R 5.30∙103 Preceding vehicle at 100 m in the case of right-hand traffic > 0.5°R to 0.9°R 7.00∙103 0.15°U Line 5 0.9°R to 0.5°L 5.30∙103 Preceding vehicle at 100 m in the case of left-hand traffic > 0.5°L to 0.9°L 7.00∙103 Line 6 Preceding vehicle at 200 m in 0.45°L to 0.1°U 1.60∙104 the case of left-hand traffic and 0.45°R right-hand traffic Angular coordinates in deg. Min. luminous Element a intensity b in cd vertical horizontal 50L 0.86°D 3.43°L 2.55∙103 Part B 50V 0.86°D 0° 5.10∙103 50R 0.86°D 1.72°R 5.10∙103 25LL 1.72°D 16°L 1.18∙103 25RR 1.72°D 11°R 1.18∙103 Notes: In Table 13, Part A and B a Angular positions are indicated for right-hand traffic. b The photometric requirements for each single measuring point or line (angular position) of this lighting function apply to half of the sum of the respective measured values from all lighting units of the system applied for this function. In case of class ADB for vehicle of category L3, not being part of a matched pair, this provision does not apply. Each of the lines defined in Part A of Table 13, in conjunction with the test points as prescribed in Part B of Table 13 shall be measured individually corresponding to the signal provided by the signal generator. In the case where the passing-beam, which meets the requirements of paragraph 5.3.2., is continuously operated in conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of Table 13 shall not be applied. For vehicles of category L3, in the case where the passing-beam which meets the requirements of paragraph 5.4.3.3. is continuously operated in conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of Table 13 shall not be applied.
5.3.3.8.added
The Driver Assistance Projection according to UN Regulation No. 48, paragraph 6.22.9.3.2., may be part of the driving-beam light distribution within a zone limited by the following angles: vertically: - 1.2° and below horizontally: ± 25° The Driver Assistance Projection may be produced by modifying the beam pattern in the zone defined above, where the luminous intensity in any point of the entire driving beam shall not exceed the maximum value (IM) according to paragraph 5.1.4.2. and not less than the minimum intensities prescribed in
5.3.3.8.1.added
The colour of the light emitted for Driver Assistance Projection shall be white.
5.3.4.1.changed
In the case of a system or part(s) thereof, which provide a bending mode, the requirements of paragraphs 5.3.2. (passing-beam), and /or and/or 5.3.3. (driving- beam) apply for all states, corresponding to the turn radius of the vehicle. For verification with respect to the passing-beam and the driving-beam the following procedure shall be used:
5.3.4.1.2.changed
When testing a category 1 or category 2 bending mode, for a turn radius of the vehicle other than specified in paragraph 5.3.4.1.1. it shall be observed whether the light distribution is substantially uniform and no undue glare occurs. If this cannot be confirmed the compliance with the requirement laid down in Table 9 7 shall be checked.
5.3.5.1.changed
It shall be stated by means of a form conforming to the model in Annex 1, which lighting unit(s) provide a "cut-off" as defined in Annex 5, that projects into a zone extending from 6 degrees left 6°L to 4 degrees right 4°R and upwards from a horizontal line positioned at 0.8 degrees down. 0.8°D.
5.3.3.3.1.deleted
The system meets the requirements of the paragraphs 5.1.3.1. class B and 5.1.3.4. above with each lighting unit measured according to the relevant procedure indicated in paragraph 5.3.4.
5.4.changed
Technical requirements concerning headlamps to provide a passing-beam of the Class AS, BS, CS, CS and DS and ES (symbols “C-AS”, “C-BS”, “WC-CS”, “WC-CS” and “WC- DS” and “WC-ES” DS”).
5.3.3.4.1.deleted
16,200 cd at the point HV:
5.4.1.1.changed
For a correct aiming The headlamp shall be aimed according to Annex 5, paragraph 3.3. including the passing beam shall produce a sufficiently sharp "cut- off" allowed specific tolerances of paragraph 4. If, however, vertical adjustment cannot be performed repeatedly to permit a satisfactory visual adjustment with its aid as indicated in paragraph 1 the required position within the allowed tolerances, the instrumental method of Annex 6. The aiming 6, paragraph 2. shall be carried out using a flat vertical screen set up at a distance of 10 or 25 m forward applied to test compliance with the required minimum quality of the headlamp symmetric "cut-off" line and at right angles to perform the H-V. The screen shall be sufficiently wide to allow examination and adjustment of the "cut-off" of the passing beam over at least 3° on either side of the V-V line. The "cut-off" shall be substantially horizontal and shall be as straight as possible from at least 3° L to 3° R. vertical adjustment.
5.4.2.changed
When so aimed, the headlamp must, if its approval is sought solely for provision of a passing beam,10 passing-beam, comply with the requirements set out in paragraphs 5.4.4.; 5.4.3.; if it is intended to provide both a passing beam passing-beam and a driving beam, driving-beam, it shall comply with the requirements set out in paragraphs 5.4.4. 5.4.3. and 5.1.
5.4.3.changed
Where a headlamp so aimed does not The passing-beam shall meet the requirements set out as shown in paragraphs 5.4.4. the applicable table below and 5.1., its alignment may be changed, except for headlamps that have no mechanism to adjust horizontal aim, on condition that 10 Such a special "passing beam" headlamp may incorporate a driving beam not subject to requirements. the axis of the beam is not displaced laterally by more than 0.5 degree to the right or left and vertically by not more than 0.25 degree up or down. To facilitate alignment by means of the "cut-off", the headlamp may be partially occulted applicable figure as shown in order to sharpen the "cut-off". However, the "cut-off" should not extend beyond the line H-H. Annex 4.
Table 14changed
10 being replaced as indicated hereunder Designation Line 1 of Table 9, Part No.18 of Table 9, Part A or B Item B of Table 10 A or B Data Set EB50L Angular coordinates in deg. a Luminous intensity in cd Imax Element vertical horizontal min max Any point in cd cut-off flat part aimed in degrees max max Zone 1 0° to 15°U 5°L to 5°R 3.20∙102 Any point on line 25L to 25R 1.72°D 5°L to 5°R 1.10∙103 b Any point on line 12.5L to 12.5R 3.43°D 5°L to 5°R 5.50∙102 Notes: In Table 14 a 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. b In case of a matched pair the contribution of each lamp shall not above E1 530 70500 0.34 D E2 440 61700 0.45 D E3 350 52900 0.57 D be less than 50% of the required minimum value on 25V (1.72°D- V)
Table 15changed
Requirements concerning the adaptation of the driving-beam according Angular coordinates in deg. a Luminous intensity in cd Element vertical horizontal min max Any point in Zone 1 0°to 15°U 5°L to paragraph 5.3.3.7. Part A Position / Deg. Max. intensity** Test 5°R 7.00∙102 Any point Horizontal Vertical (cd) Line 1 Left Oncoming vehicle on line 50L to 50R 0.86°D 2.5°L to 2.5°R 1.10∙103 except 50V Point 50V 0.86°D 0° 2.20∙103 b Any point on line 25L to 25R 1.72°D 5°L to 5°R 2.20∙103 Any point in Zone 2 0.86°D to 1.72°D 5°L to 5°R 1.10∙103 Notes: In Table 15 a 0.25 tolerance allowed independently at 50 m in the 4.8°L to 2°L 0.57°Up 625 each test point for photometry unless indicated otherwise. b In case of right-hand traffic Line 1 Right Oncoming vehicle at 50 m in a matched pair the 2°R to 4.8°R 0.57°Up 625 case contribution of left-hand traffic Line 2 Left Oncoming vehicle at 100 m in 2.4°L to 1°L 0.3°Up 1 750 the case of right-hand traffic Line 2 Right Oncoming vehicle at 100 m in 1°R to 2.4°R 0.3°Up 1 750 the case of left-hand traffic Line 3 Left 1.2°L to Oncoming vehicle at 200 m in 0.15°Up 5 450 0.5°L the case of right-hand traffic Line 3 Right 0.5°R to Oncoming vehicle at 200 m in 0.15°Up 5 450 1.2°R the case of left-hand traffic Line 4 1.7°L to1.0°R 1 850 Preceding vehicle at 50 m in the >1.0° R to case of right-hand traffic 2 500 1.7°R 0.3°Up Line 4 1.7°R to1.0°L 1 850 Preceding vehicle at 50 m in the >1.0° L to case of left-hand traffic 2 500 1.7°L Line 5 0.9° L to 5 300 Preceding vehicle at 100 m in the 0.5°R case of right-hand traffic >0.5°R to 7 000 0.9°R 0.15°Up Line 5 0.9° R to 5 300 Preceding vehicle at 100 m in the 0.5°L case of left-hand traffic >0.5°L to 7 000 0.9°L Line 6 Preceding vehicle at 200 m in the 0.45°L to 0.1°Up 16 000 case of left-hand traffic and 0.45°R right-hand traffic Part B Position /degrees* Min. Intensity** Test Point Horizontal Vertical (cd) 50R 1.72 R D 0.86 5 100 50V V D 0.86 5 100 50L 3.43 L D 0.86 2 550 25LL 16 L D 1.72 1 180 25RR 11 R D 1.72 1 180 * Angular positions are indicated for right-hand traffic. ** The photometric requirements for each single measuring point (angular position) of this lighting function apply to half of the sum of the respective measured values from all lighting units of the system applied for this function. Each of the lines defined in part A of Table 15, in conjunction with the test points as prescribed in part B of Table 15 shall be measured individually corresponding to the signal provided by the signal generator. In the case where the passing-beam, which meets the requirements of paragraph 5.3.2., is continuously operated in conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of the Table 15 lamp shall not be applied. less than 50% of the required minimum value for this test point.
Table 16changed
"Multiple Modes"- Condition "Bending Modes" passing-beam Angular coordinates in deg. a Luminous intensity in cd Element vertical horizontal min max Class CS Class DS Classes CS, DS Zone 2 > 4°U to 15°U 8°L to 8°R -- -- 7.00∙102 1°U/8°L-4°U/8°L-4°U/8°R- Zone 1 1°U/8°R-0°/4°R-0°/1°R- -- -- 9.00∙102 0.6°U/0°-0°/1°L-0°/4°L-1°U/8°L P8 4°U 8°L 7.00∙102 P9 4°U 0° ∑ 8 + 9 + 10 ≧ 1.50∙102 b 7.00∙102 P10 4°U 8°R 7.00∙102 P11 2°U 4°L 9.00∙102 P12 2°U 0° ∑ 11 + 12 + 13 ≧ 3.00∙102 b 9.00∙102 P13 2°U 4°R 9.00∙102 P14L 0° 8°L 5.0∙101 b 5.0∙101 b - Condition * if more than one mode P15L 0° 4°L 1.00∙102 b 1.00∙102 b 9.00∙102 P7 0° 0° -- -- 1.70∙103 P15R 0° 4°R 1.00∙102 b 1.00∙102 b 9.00∙102 P14R 0° 8°R 5.0∙101 b 5.0∙101 b - P3 0.86°D 3.5°L 1.38∙104 P2 0.86°D 0° 2.45∙103 c 4.90∙103 c - P1 0.86°D 3.5°R 1.38∙104 Segment 123 0.86°D 3.5°R to 3.5°L 2.00∙103 2.00∙103 - Segment 4LL 1.07°D 9°L to 3.5°L 4.25∙102 8.50∙102 - Segment 4RR 1.07°D 3.5°R to 9°R 4.25∙102 8.50∙102 - Segment 5 2°D 15°L to 15°R 5.50∙102 1.10∙103 -- 0.8 x the actual Segment 6 4°D 20°L to 20°R 1.50∙102 3.00∙102 measured value at point 1.72°D-V Notes: In Table 16 a 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. b The position lamp(s), being incorporated with the headlamp or being intended to be installed together with the headlamp may be activated according to the indications of the if applicant. c In case of a matched pair the system uses the same functional units to applicable Class exist only the mode obtain bending modes for more contribution of each lamp shall not be less than one class: which represents the worst condition has to be tested in non-bending mode Yes No according to Class C Table 17 * Category 1 ** the bending modes shall Table 18 bending mode only be tested in the Class which represents the worst  condition Category 2 Test category 2 bending mode according bending mode to Table 19 Class V Table 20 * Non Bending Mode Class V see ** Table 21 Category 1 bending mode  Class V Table 22 Category 2 bending mode "Multiple Modes"- Condition "Bending Modes" - Condition * if more than one mode 50% of the if the system uses the same functional units to applicable Class exist only the mode obtain bending modes for more than one class: which represents the worst condition has to be tested in non-bending mode Yes No according to Class W Table 23 * Non-bending mode Class W see ** Table 24 Category 1 bending mode  Class W Table 25 Category 2 bending mode Class E if more than one mode of Class E No additional testing of Category 1 and/or exists only the mode Class E Category 2 is necessary which relates to the highest cut-off position has to be tested in non- bending mode according to corresponding Table 26 to Table required minimum value.
5.4.3.3.1.added
The light shall be as evenly distributed as possible within zones 1 and 2 for Class CS or DS headlamps.
5.4.4.changed
The passing beam shall meet the requirements as shown in the applicable table below Additional light source(s) and/or additional lighting unit(s) used to produce bend lighting is (are) permitted for vehicles of categories L and the applicable figure as shown in Annex 4. Notes: For Class ES headlamps the voltage applied to the terminals of the ballast(s) is either 13.2 V ± 0.1 V for 12 V systems or as otherwise specified (see Annex 12). "D" means under the H-H line. "U" means above the H-H line. "R" means right of the V-V line. "L" means left of the V-V line. T, provided that:
5.4.4.1.changed
For Class AS headlamps (Figure A4-VIII The following requirement regarding illumination shall be met, when the principal passing-beam(s) and corresponding additional light source(s) used to produce bend lighting are activated simultaneously: (a) Left bank (when the motorcycle is rotated to the left about its longitudinal axis) the luminous intensity values shall not exceed 9.00∙102 cd in Annex 4): the zone extending from H-H to 15°U and from V-V to 10°L. (b) Right bank (when the motorcycle is rotated to the right about its longitudinal axis) the luminous intensity values shall not exceed 9.00∙102 cd in the zone extending from H-H to 15°U and from V-V to 10°R.
5.4.4.2.changed
For Class BS headlamps (Figure A4-IX in Annex 4): This test shall be carried out with the minimum bank angle specified by the applicant simulating the condition by means of the test fixture etc.
5.4.4.3.changed
For Class CS, DS or ES headlamp (Figure A4-X in Annex 4): this measurement, at the request of the applicant, principal passing-beam and additional light source(s) used to produce bend lighting, may be measured individually and the photometric values obtained combined to determine compliance with the specified luminous intensity values.
5.3.6.1.deleted
The general requirements for the Production Conformity tests are defined in Annex 2 and Annex 3. Additionally the specific tests described in relation to the photometric requirements concerning adaptive front-lighting systems (AFS) shall apply as described below. These requirements apply only for the entire system and apply to half of the sum of the respective measured values from all lighting units of the system applied for this function or mode, or, from all lighting units as indicated in the respective requirement. As an alternative to the re-alignment procedure as described in paragraph 1.2.3. of Annex 2, the intensity requirement of column A, B or C of Tables 17 to 32 for a particular direction of observation shall be deemed to be satisfied if that requirement is met in a direction deviating by not more than one-quarter of a degree from the direction of observation.
5.5.1.1.changed
The front fog lamp shall be aimed according to Annex 6 5, paragraph 3. 3.4. including the allowed specific tolerances of paragraph 4. If, however, vertical adjustment cannot be performed repeatedly to the required position within the allowed tolerances, the instrumental method of Annex 6, paragraphs 4. and 5. paragraph 2. shall be applied to test compliance with the required minimum quality of the symmetric "cut-off" line and to perform the beam vertical adjustment.
5.5.1.2.changed
The When so adjusted the front fog lamp shall meet the requirements as shown in Table 36 and Figure A4-XI in Annex 4.
5.5.2.changed
When so adjusted, the Type approval photometric requirements for front fog lamp shall meet Luminous intensity Angular coordinates in deg. Element in cd To comply vertical horizontal min max P1 and P2 60°U 45°L and 45°R P3 and P4 40°U 30°L and 30°R P5 and P6 30°U 60°L and 60°R - 8.5∙101 All points P7 and P10 20°U 40°L and 40°R P8 and P9 20°U 15°L and 15°R Line 1 8°U 26°L to 26°R - 1.30∙102 All line Line 2 4°U 26°L to 26°R - 1.50∙102 All line Line 3 2°U 26°L to 26°R - 2.45∙102 All line Line 4 1°U 26°L to 26°R - 3.60∙102 All line Line 5 0° 10°L to 10°R - 4.85∙102 All line from 5° inwards Line 6 a 2.5°D 2.70∙103 - All line to 10° outward 0.5 x the photometric requirements in actual from 5° inwards Line 7 a 6°D - measured max. All line to 10° outward value on Line 6 Line 8L and 8R 1.5°D to 3.5°D 22°L and 22°R 1.10∙103 - One or more points Line 9L and 9R 1.5°D to 4.5°D 35°L and 35°R 4.50∙102 - One or more points Zone D 1.5°D to 3.5°D 10°L to 10°R - 1.20∙104 Whole zone Notes: In Table 36 (refer also 17 a In case of lamps constituting a matched pair, the half of the sum of the respective measured values from both lamps together does not apply to Figure A4-XI this element (see paragraph 1.5. of Annex 4): 4)
5.3.6.3.1.deleted
If there is more than one mode of the driving beam only the mode corresponding to the neutral state shall be tested for CoP according to Table 30
5.5.2.1.changed
The luminous intensity shall be measured either with white light or coloured light as prescribed by the applicant for use of the fog lamp in normal service. Variations in homogeneity detrimental to satisfactory visibility in the zone above the line 5 from 10 degrees left 10°L to 10 degrees right 10°R are not permitted.
5.3.6.3.1.1.deleted
Driving Beam –bending mode –if applicable: If the system uses the same functional units to obtain bending modes for more than one class, no further testing of the bending modes of Category 1 and/or Category 2) is necessary If not, the system shall be tested according to Table 31.
5.5.2.2.changed
At Inside the request of field between lines 1 to 5 in Figure A4-X, the applicant, two front fog lamps constituting a matched pair corresponding beam pattern should be substantially uniform. Discontinuities in intensities detrimental to paragraph 3.3.2.4.3. may be tested separately. In this case satisfactory visibility between the specified requirements for lines 6, 7, 8, 8 and 9 and the Zone D in Table 36 apply to half the sum of readings of the right-hand and left-hand side front fog lamp. However each of the two front fog lamps shall meet at least 50 per cent of the minimum value required for line 6. Additionally, each of the two front fog lamps that constitute the matched pair are only required to meet the requirements of line 6 and line 7 from 5° inwards to 10° outwards. not permitted.
5.3.6.3.2.deleted
Adaptive Driving Beam–if applicable: During adaptation, the driving-beam function shall meet the requirements for all the cases of Right-Hand and/or Left-Hand traffic specified in Part A of
5.5.2.3.changed
Inside In the field between lines light-distribution as specified in Table 17, single narrow spots or stripes inside the area including the measuring points 1 to 5 in Figure A4-XI 10 and line 1 or inside the area of Annex 4, the beam pattern should line 1 and line 2 with not more than 1.75∙102 cd are allowed, if not extending beyond a conical angle of 2° aperture or a width of 1°. If multiple spots or stripes are present, they shall be substantially uniform. Discontinuities in intensities detrimental to satisfactory visibility between the lines 6, 7, 8 and 9 are not permitted. separated by a minimum angle of 10°.
Table 17deleted
Class C – non-bending mode Position/deg Column A Column B Column C Tabled requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd. No Element at/ from to at min max min max min max 1 B50L L 3.43 U 0.57 50 350 25 520 10 605 3 BR R 2.5 U 1 50 1750 25 2100 10 2275 4 Point BRR R 8 U 0.57 50 3550 25 4260 10 4615 5 Point BLL L 8 U 0.57 50 625 25 880 10 1005 7 Line III L 4 V V H 625 880 1005 8a S50+S50LL+S50RR3 U 4 1902 1875 952 2250 452 2440 9a S100+S100LL+S100RR3 U 2 3752 1875 1852 2250 902 2440 10 50 R R 1.72 D 0.86 44100 52920 57330 11 75 R …
5.5.3.1.changed
In To adapt to dense fog or similar conditions of reduced visibility, it is permitted to automatically vary the case of luminous intensities provided that: (a) An active electronic light source control gear is incorporated into the front fog lamps equipped with gas-discharge light sources with lamp function system; (b) All intensities are varied proportionately. The system, when checked for compliance according to the ballast not integrated with the light source, provisions of paragraph 4.6.2.1., is considered acceptable if the luminous intensity shall exceed 1,080 cd in the measuring point at 0° horizontal intensities remain within 60 per cent and 2° D vertical four seconds after activation 100 per cent of the fog lamp which has not been operated for 30 minutes or more. values specified in Table 17.
5.5.3.1.1.added
An indication shall be inserted in the communication form (Annex 1, item 9).
5.5.3.1.2.added
The Technical Service responsible for type approval shall verify that the system provides automatic modifications, such that good road illumination is achieved and no discomfort is caused to the driver or to other road users.
5.5.3.1.3.added
Photometric measurements shall be performed according to the applicant's description.
5.6.1.added
The cornering lamp shall be installed on the goniometer according to Annex 5, paragraph 3.5. including the allowed specific tolerances of paragraph 4. For a left side lamp, the intensity of the light at the specified measuring points and zones shall be as indicated in Table 18.
Table 18changed
Class C – Bendlight Cat. 1 Position/deg Column A Column B Column C Tabled Type approval photometric requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed for cornering lamp (left side lamp) Angular coordinates in deg.a Luminous intensity in cd No Element at/ from to at vertical horizontal min max min max min max Zone 1 B50L L 3.43 U 0.57 530 700 785 Above 1°U 90°L to 90°R - 3.00∙102 Zone 2 0° to 1°U 90°L to 90°R - 6.00∙102 Zone 3 BR R 2.5 U 1 1750 2100 2275 4 Point BRR R 8 U 0.57 3550 4260 4615 5 Point BLL L 8 U 0.57 625 880 1005 7 Line III L 4 V V H 880 1135 1260 10 50 R R 1.72 D 0.86 44100 52920 57330 11 75 R R 1.15 D 0.57 10100 44100 8080 52920 7070 57330 12 50 V V D 0.86 5100 44100 4080 52920 3570 57330 Class C – Bendlight Cat. 1 Position/deg Column A Column B Column C Tabled requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from Below 0° 90°L to 90°R - 1.40∙104 P1 2.5°D 30°L 3.75∙102 - P2 2.5°D 45°L 6.25∙102 - P3 2.5°D 60°L 3.75∙102 - Notes: In Table 18 a 0.25 tolerance allowed independently at min max min max min max 13 50 L L 3.43 D 0.86 1700 132001 2840 158401 2485 171601 Note to Table 18: 1 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as each test point for photometry, unless indicated in the communication form. otherwise.
5.6.2.added
In the case of a single lamp containing more than one light source when all light sources are illuminated the maximum intensities shall not be exceeded.
5.6.3.changed
Photometric measurement Failure of lamps equipped with several a single lamp containing more than one light sources. The photometric performance shall be checked: source:
5.6.3.1.changed
In case a single lamp containing more than one light source, a group of non-replaceable light sources, with wired so that the failure of any one of them causes all of them to stop emitting light, shall be considered to be one light sources present in the lamp, in accordance with paragraph 4.6. source.
5.6.3.2.changed
In case of replaceable failure of any one light sources, source in addition to a single lamp containing more than one light source, at least one of the following provisions shall apply: (a) The light intensity complies with the minimum intensity required in the table of standard light distribution in space as shown in Table 18; or (b) A signal for activation of a tell-tale indicating failure, as indicated in paragraph 4.6. The 6.20.8. of UN Regulation No. 48, is produced, provided that the luminous intensity values produced shall at 2.5°D 45°L for a left-side lamp (the L angle should be corrected. (a) For filament light sources substituted for the correction factor R angle for a right-side lamp) is the ratio between the reference luminous flux and the mean value at least 50 per cent of the luminous flux found at minimum intensity required. In this case a note in the voltage applied (13.2 V or 13.5 V); (b) For LED light sources communication form states that the correction factor lamp is the ratio between the objective luminous flux and the mean value of the luminous flux found at the voltage applied (6.75 V, 13.5 V or 28.0 V). The actual luminous fluxes of each light source used shall not deviate more than ±5 per cent from the mean value. Alternatively and in case of filament light sources only, only for use on a standard filament light source may be used in turn, in each of the individual positions, operated at its reference flux, the individual measurements in each position being added together. vehicle fitted with a tell-tale indicating failure.
5.6.4.1.added
Measuring points expressed in degrees of angle with the axis of reference are shown in Figure A4-XI.
5.6.4.2.added
Horizontal and vertical angles for the field of geometric visibility are shown in Figures A4-XII and A4-XIII. The directions H = 0° and V = 0° correspond to the axis of reference. On the vehicle they are horizontal, parallel to the median longitudinal plane of the vehicle and oriented in the required direction of visibility. They pass through the centre of reference.
6.1.1.changed
Contracting Parties applying Road illumination devices approved under this Regulation shall continue be so manufactured as to accept type approvals of the lamps (functions), to any of the preceding series of amendments to this Regulation, which are not affected by the changes introduced by the latest series of amendments. To verify this, the change index applicable conform to the pertinent lamp (function) shall not differ from its change index as indicated type approved by meeting the requirements set forth in the latest series of amendments. paragraphs 4.16. and 5.
6.1.1.1.added
The minimum requirements for conformity of production control procedures set forth in Annex 2 shall be complied with;
5.4.1.2.deleted
The headlamp shall be aimed according to paragraph 3. of Annex 6. If, however, vertical adjustment cannot be performed repeatedly to the required position within the allowed tolerances, the instrumental method of Annex 6, paragraphs 4 and 5 shall be applied to test compliance with the required minimum quality of the "cut-off" line and to perform the beam vertical adjustment.
6.1.1.2.added
The minimum requirements for sampling by an inspector set forth in Annex 3 shall be complied with.
6.1.2.changed
Contracting Parties applying this Regulation The Type Approval Authority which has granted type approval may at any time verify the conformity control methods applied in each production facility. The normal frequency of these verifications shall not refuse to grant extensions to type approvals according to any preceding series of amendments to this Regulation. be once every two years.
6.1.3.added
Road illumination devices with apparent defects are disregarded.
6.1.4.added
The reference mark is disregarded.
6.1.5.added
The measuring points in Table 6 Part B are disregarded.
6.1.6.added
The measuring points P8 to P15 in Table 16 are disregarded.
6.1.7.added
Testing with LED substitute light sources is exempted from conformity of production control
6.1.8.added
The conformity requirements shall be considered satisfied from a mechanical and a geometric standpoint, in accordance with the requirements of this Regulation, if any, if the differences do not exceed inevitable manufacturing deviations.
6.1.9.added
In the case of cornering lamps using non-replaceable filament light source(s) or light source module(s) equipped with non-replaceable filament light sources, at any conformity of production check:
6.1.9.1.added
the holder of the approval mark shall demonstrate the use in normal production and show the identification of the non-replaceable filament light source(s) as indicated in the type approval documentation;
6.1.9.2.added
in the case where doubt exists in respect to compliance of the non-replaceable filament light source(s) with lifetime requirements and/or, in the case of colour coated filament light sources, with colour endurance requirements, as specified in paragraph 4.11 of IEC 60809, Edition 4, conformity shall be checked as specified in paragraph 4.11 of IEC 60809, Edition 4.
5.4.4.4.deleted
The light shall be as evenly distributed as possible within zones 1 and 2 for Class CS, DS or ES headlamps.
5.4.4.5.deleted
Either one or two filament light sources (Classes AS, BS, CS, DS) or one gas discharge light source (Class ES) or one or more LED light source(s) or LED module(s) (Classes AS, BS, CS, DS, ES) are permitted for the passing beam.
6.2.1.added
With respect to photometric performances, the conformity of mass-produced lamps shall not be contested if, when testing photometric performances of any lamp chosen at random and equipped with a standard (étalon) light source and/or non-replaceable light source(s) and/or light source module(s), as present in the lamp;
5.4.5.deleted
Additional light source(s) and/or additional lighting unit(s) used to produce bend lighting is (are) permitted for vehicles of categories L and T, provided that:
6.2.1.1.added
If not otherwise specified, no measured value deviates unfavorably by more than 20 per cent from the value prescribed in this Regulation.
5.4.5.1.deleted
The following requirement regarding illumination shall be met, when the principal passing beam(s) and corresponding additional light source(s) used to produce bend lighting are activated simultaneously: (a) Left bank (when the motorcycle is rotated to the left about its longitudinal axis) the luminous intensity values shall not exceed 900cd in the zone extending from HH to 15 deg above HH and from VV to 10 deg left. (b) Right bank (when the motorcycle is rotated to the right about its longitudinal axis) the luminous intensity values shall not exceed 900cd in the zone extending from HH to 15 deg above HH and from VV to 10 deg right.
6.2.1.1.1.added
For class C and V passing-beam corresponding to paragraph 5.2. of this Regulation the conformity of mass-produced lamps shall not be contested if:
5.4.5.2.deleted
This test shall be carried out with the minimum bank angle specified by the applicant simulating the condition by means of the test fixture etc.
6.2.1.1.1.1.added
the maximum unfavorable deviation for the point B50L (or R) and zone III, may be respectively: B50L (or R): 1.70∙102 cd equivalent 20 per cent 2.55∙102 cd equivalent 30 per cent Zone III: 2.55∙102 cd equivalent 20 per cent 3.80∙102 cd equivalent 30 per cent and no measured value deviates unfavorably by more than 20 per cent from the value prescribed in Table 6 for all other elements (points, segments and zones). or:
5.4.5.3.deleted
For this measurement, at the request of the applicant, principal passing beam and additional light source(s) used to produce bend lighting, may be measured individually and the photometric values obtained combined to determine compliance with the specified luminous intensity values.
6.2.1.1.1.2.added
at one point within a circle of 0.35 degrees radius around points B50L (or R) (with a tolerance of 85 cd), 75R (or L), 50V, 40R, 40L, and in the entire segment 50, the values prescribed in Table 6 are met (the deviation of 20 per cent from the values prescribed does not apply).
6.2.1.1.1.2.1.added
and if, for the driving-beam, HV being situated within the isocandela 0.75 Imax a tolerance of + 20 per cent for maximum values and -20 per cent for minimum values is observed for the photometric values at any measuring point specified in paragraph 5.1. of this Regulation
6.2.1.1.1.3.added
If the results of the test described above do not meet the requirements, the alignment of the headlamp may be changed according to the provisions in Annex 5, paragraph 4.1.
6.2.1.1.2.added
For class BS, CS and DS headlamps corresponding to paragraph 5.4. of this Regulation for values in zone I, the maximum unfavorable deviation may be respectively: Zone I: 2.55∙102 cd equivalent 20 per cent 3.80∙102 cd equivalent 30 per cent
6.2.1.1.2.1.added
If the results of the test described above do not meet the requirements, the alignment of the headlamp may be changed according to the provisions in Annex 5, paragraph 4.1.
6.2.1.1.3.added
For front fog lamps corresponding to paragraph 5.5. of this Regulation,
Table 19changed
Class C – Bendlight Cat. 2 Position/deg Column A Column B Column C Tabled Conformity of production, photometric requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed for front fog lamp Luminous intensity in cd No Angular coordinates in deg. Equivalent Equivalent Element at/ from to at To comply 20 per cent 30 per cent vertical horizontal min max min max min max P1 and P2 60°U 45°L and 45°R P3 and P4 40°U 30°L and 30°R P5 and P6 30°U 60°L and 60°R - 1.15∙102 - 1.30∙102 All points P7 and P10 20°U 40°L and 40°R P8 and P9 20°U 15°L and 15°R Line 1 B50L L 3.43 U 0.57 530 700 785 8°U 26°L to 26°R - 1.60∙102 - 1.70∙102 All line Line 2 4°U 26°L to 26°R - 1.80∙102 - 1.95∙102 All line Line 3 BR 2°U 26°L to 26°R - 2.95∙102 - 3.20∙102 All line Line 4 1°U 26°L to 26°R - 4.35∙102 - 4.70∙102 All line Line 5 0° 10°L to 10°R - 5.85∙102 - 6.30∙102 All line from 5° inwards Line 6 a 2.5°D 2.16∙103 - 1.89∙103 - All line to 10° outward Line 8L One or 1.5°D to 3.5°D 22°L and 22°R 8.80∙102 - 7.70∙102 - and 8R more points Line 9L One or 1.5°D to 4.5°D 35°L and 35°R 3.60∙102 - 3.15∙102 - and 9 R 2.5 U more points Zone D 1.5°D to 3.5°D 10°L to 10°R - 1.44∙104 - 1.56∙104 Whole zone Notes: In Table 19 a In case of lamps constituting a matched pair, the half of the sum of the respective measured values from both lamps together does not apply to this element (see paragraph 1.5. of Annex 4) 6.2.1.1.3.1 In the light-distribution as specified in Table 19, single narrow spots or stripes inside the area including the measuring points 1 1750 2100 2275 4 Line BRR R 8 R 20 U 0.57 3550 4260 4615 5 Line BLL L 8 L 20 U 0.57 625 880 1005 7 Line III L 4 V V H 880 1135 1260 to 10 and line 1 or inside the area of line 1 and line 2 with not more than 2.10∙102 cd are allowed, if not extending beyond a conical angle of 2° aperture or a width of 1°. If multiple spots or stripes are present, they shall be separated by a minimum angle of 10°.
6.2.1.1.3.2.added
If the results of the test described above do not meet the requirements, the alignment of the front fog lamp may be changed according to the provisions in Annex 5, paragraph. 4.1.
6.2.1.1.4.added
For AFS corresponding to paragraph 5.3. no value measured and corrected according to the prescriptions of paragraph 4.6., deviates unfavourably from the value prescribed in column B of Tables 21 to 36, if applicable.
5.5.2.4.deleted
In the light-distribution as specified in Table 36, single narrow spots or stripes inside the area including the measuring points 1 to 10 and line 1 or inside the area of line 1 and line 2 with not more than 175 cd are allowed, if not extending beyond a conical angle of 2° aperture or a width of 1°. If multiple spots or stripes are present they shall be separated by a minimum angle of 10°.
Table 20changed
"Bending Modes" - Condition "Multiple Modes"- Condition if the system uses the same functional units to obtain bending modes for more than one class: Yes No Class C Table 21a Category 1 See b Table 22 bending mode → Category 2 Test category 2 bending mode according to bending mode Table 23 Class V -non-bending Non-Bending Table 24a Mode Class V Category 1 Table 25 bending mode Position/deg Column A Column B Column C Tabled requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed → see b Class V Category 2 Table 26 bending mode Class W Non-bending Table 27a mode Class W Category 1 Table 28 bending mode → see b Class W Category 2 Table 29 bending mode if more than one mode of Class E exists only the mode Class E which relates to the No additional testing of Category 1 and/or Class E highest cut-off position has to be tested in cd No Element at/ from to at min max min max min max 1 B50L L 3.43 U 0.57 350 520 605 3 BR R 2.5 U 1 880 1135 1260 4 Point BRR R 8 U 0.57 880 1135 1260 5 Point BLL L 8 U 0.57 880 1135 1260 7 Line III L 4 V V H 625 880 1005 10 50 R R 1.72 D 0.86 5100 44100 4080 52920 3570 57330 13 50 L L 3.43 D 0.86 3550 132001 2840 158401 2485 171601 Note to Table 20: 1 The maximum value may be multiplied by 1.4, if it Category 2 is guaranteed necessary non-bending mode according to the manufacturer’s description that value will not be exceeded in use, either by means corresponding Table 30 to Table 33 Notes: In Table 20: a If more than one mode of the system or, if applicable Class exists, only the system’s use is confined mode which represents the worst condition has to vehicles, providing a corresponding stabilization/limitation of be tested in non-bending mode according to Tables 21, 24 or 27. b the system’s supply, as indicated bending modes shall only be tested in the communication form. Class which represents the worst condition
5.5.2.5.deleted
If the specified luminous intensity requirements are not met, a re-aim of the cut-off position within ±0.5° vertical and/or ±2° horizontal is allowed. In the re-aimed position all photometric requirements shall be met.
Table 21changed
Class V – Bendlight Cat. 1 Position/deg (indicated for right-hand traffic) Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Tabled requirements horizontal vertical Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at vertical horizontal min max min max min max 1 B50L L 3.43 U 0.57 530 700 785 3 S50+S50LL+ As specified in Table 11 1.90∙102 a - 9.5∙101 a - 4.5∙101 a - S50RR S100+S100LL As specified in Table 11 3.75∙102 a - 1.85∙102 a - 9.0∙101 a - +S100RR BR R 2.5 U 1 880 1135 1260 4 Point BRR R 8 U 0.57 880 1135 1260 5 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL L 8 U 0.57 880 1135 1260 7 0.57°U 8°L - 6.25∙102 - 8.80∙102 - 1.01∙103 B50L 0.57°U 3.43°L - 3.50∙102 - 5.20∙102 - 6.05∙102 Line III L 4 V V H 880 1135 1260 0° 4°L to 0° - 6.25∙102 - 8.80∙102 - 1.01∙103 75R 0.57°D 1.15°R 1.21∙104 - 9.68∙103 - 8.47∙103 - 50L 0.86°D 3.43°L 5.00∙103 3.70∙104 4.00∙103 4.44∙104 3.50∙103 4.81∙104 50V 0.86°D 0° 5.10∙103 - 4.08∙103 - 3.57∙103 - 50R 0.86°D 1.72°R 1.01∙104 - 8.08∙103 - 7.07∙103 - 25LL 1.72°D 16°L 1.18∙103 - 9.44∙102 - 8.26∙102 - 25RR 1.72°D 11°R 1.18∙103 - 9.44∙102 - 8.26∙102 - 0,8 x the 0,8 x the 0,8 x the actual actual actual Segment 10 50 R R 1.72 D 0.86 5100 44100 4080 52920 3570 57330 13 50 L L 3.43 D 0.86 1700 132001 2840 158401 2485 171601 Note 4°D 4.5°L to 2°R measured measured measured value at 50R value at 50R value at 50R Notes: In Table 21: 1 The maximum value a One pair of position lamps, being incorporated with the system or being intended to be installed together with the system may be multiplied by 1.4, if it is guaranteed activated according to the manufacturer’s description that this value will not be exceeded in use, either by means indications of the system or, of the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. applicant.
Table 22changed
Class V – Bendlight Cat. 2 Position/deg (indicated for right-hand traffic) Luminous intensity in cd Angular coordinates Column A Column B Column C Tabled requirements horizontal vertical Element in deg. ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at vertical horizontal min max min max min max 1 BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 6.25∙102 - 8.80∙102 - 1.01∙103 B50L L 3.43 U 0.57 530 700 785 3 BR R 2.5 U 1 880 1135 1260 4 Line BRR R 8 R 20 U 0.57 880 1135 1260 5 Line BLL L 8 L 20 U 0.57 880 1135 1260 7 0.57°U 3.43°L - 5.30∙102 - 7.00∙102 - 7.85∙102 Line III L 4 V V H 880 1135 1260 0° 4°L to 0° - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.21∙104 - 9.68∙103 - 1.21∙104 - 50L 0.86°D 3.43°L 1.70∙103 - 1.36∙103 - 1.19∙103 - 50V 0.86°D 0° 5.10∙103 - 4.08∙103 - 5.10∙103 - 50R 0.86°D 1.72°R 1.01∙104 - 8.08∙103 - 7.07∙103 -
Table 23changed
Class W – non-bending mode Position/deg (indicated for right-hand traffic) Luminous intensity in cd Angular coordinates Column A Column B Column C Tabled requirements horizontal vertical Element in deg ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at vertical horizontal min max min max min max 1 BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Line BLL 0.57° U 20°L to 8°L - 6.25∙102 - 8.80∙102 - 1.01∙103 B50L L 3.43 0.57° U 0.57 625 880 1005 3 BR R 2.5 U 1 2650 3180 3445 4 Point BRR R 8 U 0.57 5300 6360 6890 5 Point BLL L 8 U 0.57 880 1135 1260 7 3.43°L - 5.30∙102 - 7.00∙102 - 7.85∙102 Line III b 0° 4° L 4 L 0.5 U 0.34 880 1135 1260 Class W – non-bending mode Position/deg Column A Column B Column C Tabled requirements horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at min max min max min max 11 75 R R 1.15 D 0.57 20300 705001 16240 846001 14210 916501 13 50 L L 3.43 D 0.86 6800 264002 5440 316802 4760 343202 14 25 LL L 16 D 1.72 3400 705001 2720 846001 2380 916501 15 25 RR R 11 D 1.72 3400 705001 2720 846001 2380 916501 16 Segment 20 L 3.5 V D 2 176001 211201 228801 17 Segment 10 L 4.5 R 2.0 D 4 123001 147601 159901 Line E L 20 R 20 U 10 175 260 300 Notes to Table 23: 1 If, according to the applicants specification according to paragraph 3.1.3.2. (e) of this Regulation a class W passing beam is designed to produce on segment 20 and below it not more than 8,800 cd (10,560 cd corresponds to 20% CoP, 11,440 cd corresponds to 30% CoP) and on segment 10 and below it not more than 3,550 cd (4,260 cd corresponds to 20% CoP and 4,615 cd corresponds to 30% CoP), the design value for I max of that beam shall not exceed 88,100 cd (105,720 corresponds to 20% CoP, 114,530 cd corresponds to 30% CoP). 2 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 0° - 8.80∙102 - 1.14∙103 - 1.26∙103
5.5.3.2.deleted
To adapt to dense fog or similar conditions of reduced visibility, it is permitted to automatically vary the luminous intensities provided that: (a) An active electronic light source control gear is incorporated into the front fog lamp function system; (b) All intensities are varied proportionately. The system, when checked for compliance according to the provisions of paragraph 4.6.6., is considered acceptable if the luminous intensities remain within 60 per cent and 100 per cent of the values specified in Table 36.
Table 24changed
Class W – Bendlight Cat. 1 Position/deg (indicated for right-hand traffic) Luminous intensity in cd Angular coordinates Column A Column B Column C Tabled requirements horizontal vertical Element in deg ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at vertical horizontal min max min max min max 1 B50L L 3.43 U 0.57 790 960 1045 3 BR R 2.5 U 1 2650 3180 3445 4 Point BRR R 8 U 0.57 5300 6360 6890 5 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL L 8 U 0.57 880 1135 1260 7 0.57°U 8°L - 6.25∙102 - 8.80∙102 - 1.01∙103 B50L 0.57°U 3.43°L - 3.50∙102 - 5.20∙102 - 6.05∙102 Line III b L 4 L 0.5 U 0.34 880 1135 1260 11 75 R R 1.15 D 0.57 20300 705001 16240 846001 14210 916501 13 50 L L 3.43 D 0.86 3400 132002 2720 158402 2380 171602 Notes 0° 4°L to Table 24: 1 If, according to the applicants specification according to paragraph 3.1.3.2 (e) of this Regulation a class W passing beam is designed to produce on segment 20 and below it mot more than 8,800 cd (10,560 cd corresponds to 20% CoP, 11,440 cd corresponds to 30% CoP) and on segment 10 and below it not more than 3,550 cd (4,260 cd corresponds to 20% CoP and 4,615 cd corresponds to 30% CoP), the design value for I max of that beam shall not exceed 88,100 cd (105,720 corresponds to 20% CoP, 114,530 cd corresponds to 30% CoP). 2 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 0° - 6.25∙102 - 8.80∙102 - 1.01∙103 50L 0.86°D 3.43°L 3.55∙103 3.70∙104 2.84∙103 4.44∙104 2.49∙103 4.81∙104 50R 0.86°D 1.72°R 5.10∙103 4.41∙104 4.08∙103 5.29∙104 3.57∙103 5.73∙104
5.5.3.2.1.deleted
An indication shall be inserted in the communication form (Annex 1, item 9).
Table 25changed
Class W – Bendlight Cat. 2 Position/deg (indicated for right-hand traffic) Luminous intensity in cd Angular coordinates Column A Column B Column C Tabled requirements horizontal vertical Element in deg ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd N Element o at/ from to at vertical horizontal min max min max min max 1 BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L L 3.43 U 0.57 790 960 1045 3 BR R 2.5 U 1 2650 3180 3445 4 Line BRR R 8 R 20 U 0.57 5300 6360 6890 5 Line BLL L 8 L 20 U 0.57 880 1135 1260 7 0.57°U 3.43°L - 5.30∙102 - 7.00∙102 - 7.85∙102 Line III b L 4 L 0.5 U 0.34 880 1135 1260 0° 4°L to 0° - 8.80∙102 - 1.14∙103 - 1.26∙103 50L 0.86°D 3.43°L 1.70∙103 - 1.36∙103 - 1.19∙103 - 50R 0.86°D 1.72°R 5.10∙103 4.41∙104 4.08∙103 5.29∙104 3.57∙103 5.73∙104
5.5.3.2.2.deleted
The Technical Service responsible for type approval shall verify that the system provides automatic modifications, such that good road illumination is achieved and no discomfort is caused to the driver or to other road users.
Table 26changed
Class E - non-bending mode Position/deg (indicated for right-hand traffic) Luminous intensity in cd Angular coordinates Column A Column B Column C Tabled requirements horizontal vertical Element in deg ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP expressed in cd No Element at/ from to at vertical horizontal min max min max min max 1 BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Line BLL 0.57° U 20°L to 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L L 3.43 0.57° U 0.57 625 880 1005 3 BR R 2.5 U 1 1750 2100 2275 4 Point BRR R 8 U 0.57 3550 2100 2275 5 Point BLL L 8 U 0.57 880 1135 1260 7 3.43°L - 5.30∙102 - 7.00∙102 - 7.85∙102 Line III b 0° 4° L 4 L 0.5 U 0.34 880 1135 1260 11 75 R R 1.15 D 0.57 15200 79300 12160 95160 10640 103090 12 50 V V D 0.86 10100 79300 8080 95160 7070 103090 13 50 L L 3.43 D 0.86 6800 793001 5440 951601 4760 1030901 Note to Table 26: 1 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 0° - 8.80∙102 - 1.14∙103 - 1.26∙103
5.5.3.2.3.deleted
Photometric measurements shall be performed according to the applicant's description.
Table 27changed
Class E1 – non-bending Position/degrees (indicated for right-hand traffic) Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C mode Tabled requirements expressed in cd horizontal vertical Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP No Element at/ from to at vertical horizontal min max min max min max 1 B50L L 3.43 U 0.57 530 700 785 3 BR R 2.5 U 1 1750 2100 2275 4 Point BRR R 8 U 0.57 3550 2100 2275 5 1°U 2.5°R - 2.65∙103 - 3.18∙103 - 3.45∙103 Point BLL L 8 U 0.57 880 1135 1260 Class E1 – non-bending Position/degrees Column A Column B Column C mode Tabled requirements expressed in cd horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP No Element at/ from to at min max min max min max 7 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 6.25∙102 - 8.80∙102 - 1.01∙103 Line III b L 4 L 0.5 U 0.34 880 1135 1260 11 75 R R 1.15 D 0.57 15200 70500 12160 84600 10640 91650 12 50 V V D 0.86 10100 70500 8080 84600 7070 91650 13 50 L 84600 L 3.43 D 0.86 6800 705001 5440 1 4760 916501 Note 0.34°U 4°L to Table 27: 1 The maximum value may be multiplied by 1.4, if it is guaranteed according 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 6.80∙103 3.70∙104 5.44∙103 4.44∙104 4.76∙103 4.81∙104 25LL 1.72°D 16°L 1.18∙103 - 9.44∙102 - 8.26∙102 - 25RR 1.72°D 11°R 1.18∙10 3 - 9.44∙10 2 - 8.26∙102 - Segment 20 2°D 3.5°L to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined 0° - 1.76∙104 - 2.11∙104 - 2.29∙104 Segment 10 4°D 4.5°L to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 2°R - 7.10∙103 - 8.52∙103 - 9.23∙103
5.5.4.deleted
Tolerance requirements for conformity of production control procedure:
Table 28changed
Class E2 – non-bending mode Position/degrees (indicated for right-hand traffic) Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Tabled requirements expressed in cd horizontal vertical Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP No Element at/ from to at vertical horizontal min max min max min max 1 B50L L 3.43 U 0.57 440 610 695 3 BR R 2.5 U 1 1750 2100 2275 4 Point BRR R 8 U 0.57 3550 2100 2275 5 1°U 2.5°R - 7.90∙102 - 9.60∙102 - 1.05∙103 Point BLL L 8 U 0.57 880 1135 1260 7 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 7.90∙102 - 9.60∙102 - 1.05∙103 Line III b L 4 L 0.5 U 0.34 880 1135 1260 11 75 R R 1.15 D 0.57 15200 61700 12160 74040 10640 80210 12 50 V V D 0.86 10100 61700 8080 74040 7070 80210 13 50 L L 3.43 D 0.86 6800 617001 5440 740401 4760 802101 Note 0.34°U 4°L to Table 28: 1 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 3.40∙103 - 2.72∙103 - 2.38∙103 -
5.5.4.1.deleted
When testing the photometric performances of any front fog lamp chosen at random according to paragraph 5.5., no measured value of the luminous intensity may deviate unfavourably by more than 20 per cent
Table 29changed
Class E3 - non-bending mode Position/degrees (indicated for right-hand traffic) Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Tabled requirements expressed in cd horizontal vertical Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP No Element at/ from to at vertical horizontal min max min max min max 1 BR 1°U 2.5°R - 7.90∙102 - 9.60∙102 - 1.05∙103 Line BLL 0.57°U 20°L to 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L L 3.43 U 0.57 350 520 605 3 BR R 2.5 U 1 1750 2100 2275 4 Point BRR R 8 U 0.57 3550 2100 2275 Class E3 0.57°U 3.43°L - non-bending mode Position/degrees Column A Column B Column C Tabled requirements expressed in cd horizontal vertical ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP No Element at/ from to at min max min max min max 5 Point BLL L 8 U 0.57 880 1135 1260 7 7.90∙102 - 9.60∙102 - 1.05∙103 Line III b L 4 L 0.5 U 0.34 880 1135 1260 11 75 R R 1.15 D 0.57 15200 52900 12160 63480 10640 68770 12 50 V V D 0.86 10100 52900 8080 63480 7070 68770 13 50 L L 3.43 D 0.86 6800 529001 5440 634801 4760 687701 Note 0.34°U 4°L to Table 29: 1 The maximum value may be multiplied by 1.4, if it is guaranteed according to the manufacturer’s description that this value will not be exceeded in use, either by means of the system or, if the system’s use is confined to vehicles, providing a corresponding stabilization/limitation of the system’s supply, as indicated in the communication form. 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103
5.5.4.2.deleted
For the measured values in Table 36 the respective maximum deviations may be:
Table 30changed
Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Required luminous Required luminous Required luminous Driving Beam Straight Ahead Angular Coordinates intensity intensity intensity Test Point (degrees) (cd) Element ≙ 0% CoP (cd) ≙ 20% CoP (cd) ≙ 30% CoP Min Max Min Max Min Max HV H,V 32,400 215,000 26,000 258,000 23,000 279,500 H-5L 0.0, 5.0 L 5,100 215,000 4,080 258,000 3,570 279,500 H-2.5L 0.0, 2.5 L 20,300 215,000 16,240 258,000 14,210 279,500 H-2.5R 0.0, 2.5 R 20,300 215,000 16,240 258,000 14,210 279,500 H-5R 0.0, 5.0 R 5,100 215,000 4,080 258,000 3,570 279,500 vertical horizontal min max min max min max BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 6.25∙102 - 8.80∙102 - 1.01∙103 Line III b 0.34°U 4°L to 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 6.80∙103 - 5.44∙103 - 4.76∙103 - 50V 0.86°D 0° 1.01∙104 - 8.08∙103 - 7.07∙103 -
Table 37deleted
Luminous intensity candela Vertical position* Horizontal position* Designated lines or above h + left of v: - To comply zones Equivalent Equivalent below h - right of v: + 20 per cent 30 per cent Point 1, 2** +60° ±45° 115 max 130 max Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° All points Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 160 max 170 max All line Line 2** +4° -26° to +26° 180 max 195 max All line Line 3 +2° -26° to +26° 295 max 320 max All line Line 4 +1° -26° to +26° 435 max 470 max All line Line 5 0° -10° to +10° 585 max 630 max All line Line 6*** -2.5° from 5° inwards 1,890 min All line …
Table 31changed
Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Required luminous Required luminous Required luminous Driving Beam Bendlight Angular Coordinates intensity intensity intensity Test Point (degrees) (cd) ≙ 0% CoP (cd) ≙ 20% CoP (cd) ≙ 30% CoP Min Max Min Max Min Max HV H,V 32,400 215,000 26,000 258,000 23,000 279,500 H-5L 0.0, 5.0 L 4,080 215,000 3,264 258,000 2,856 279,500 H-2.5L 0.0, 2.5 L 16,240 215,000 12,992 258,000 11,368 279,500 H-2.5R 0.0, 2.5 R 16,240 215,000 12,992 258,000 11,368 279,500 H-5R 0.0, 5.0 R 4,080 215,000 3,264 258,000 2,856 279,500 Class R – Adaptive Driving Beam – COP Values Column A Column B Column C Max. Max. Max. Position/Deg. Intensity** Intensity** Intensity** Test Point Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP Horizontal Vertical (cd) (cd) (cd) vertical horizontal min max min max min max BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 5.30∙102 - 7.00∙102 - 7.85∙102 Line 1 Left Oncoming vehicle at 50 m in the case of Right- 4.8°L III b 0.34°U 4°L to 2°L 0.57°Up 625 880 1003 Hand Traffic Line 1 Right Oncoming vehicle at 50 m in the case of Left-Hand 2°R to 4.8°R 0.57°Up 625 880 1003 Traffic Line 2 Left Oncoming vehicle at 100 m in the case of Right- 2.4°L to 1°L 0.3°Up 1750 2100 2275 Hand Traffic Line 2 Right Oncoming vehicle at 100 m in the case of Left- 1°R to 2.4°R 0.3°Up 1750 2100 2275 Hand Traffic Line 3 Left 1.2°L to Oncoming vehicle at 200 m in the case of Right- 0.15°Up 5450 6540 7085 0.5°L Hand Traffic Part A Line 3 Right 0.5°R to Oncoming vehicle at 200 m in the case of Left- 0.15°Up 5450 6540 7085 1.2°R Hand Traffic 1.7°L to Line 4 1850 2220 2405 1.0°R Preceding vehicle at 50 m in the case of Right- Hand Traffic >1.0°R to 2500 3000 3250 1.7°R 0.3°Up 1.7°R to Line 4 1850 2220 2405 1.0°L Preceding vehicle at 50 m in the case of Left-Hand Traffic >1.0°L to 2500 3000 3250 1.7°L 0.9°L to Line 5 5300 6360 6890 0.5°R Preceding vehicle at 100 m in the case of Right- Hand Traffic >0.5°R to 7000 8400 9100 0.9°R 0.15°Up 0.9°R to Line 5 5300 6360 6890 0.5°L Preceding vehicle at 100 m in the case of Left- Hand Traffic >0.5°L to 7000 8400 9100 0.9°L Line 6 0.45°L to Preceding vehicle at 200 m in the case of Left- 0.1°Up 16000 19200 20800 0.45°R Hand Traffic and Right-Hand Traffic Column A Column B Column C Position /degrees* Min. Intensity**≙ 0% Min. Intensity** ≙ Min. Intensity** ≙ Test Point CoP 20% CoP 30% CoP Horizontal Vertical (cd) (cd) (cd) Part B 50R 1.72 R D 0.86 5 100 4080 3570 - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 6.80∙103 - 5.44∙103 - 4.76∙103 - 50V V D 0.86 5 100 4080 3570 50L 3.43 L D 0.86 2 550 2040 1785 25LL 16 L D 1.72 1 180 944 826 25RR 11 R D 1.72 1 180 944 826 Notes to Table 32 * Angular positions are indicated for right-hand traffic. ** The photometric requirements for each single measuring point (angular position) of this lighting function apply to half of the sum of the respective measured values from all lighting units of the system applied for this function. Each of the lines defined in part A of Table 32, in conjunction with the test points as prescribed in part B of Table 32 shall be measured individually corresponding to the signal provided by the signal generator. In the case where the passing beam, which meets the requirements of paragraph 5.3.6.2., is continuously operated in conjunction with the adaptation of the driving beam, the photometric requirements in Part B of Table 32 shall not be applied. 0.86°D 0° 1.01∙104 - 8.08∙103 - 7.07∙103 -
Table 32changed
beam only Angular coordinates Luminous intensity in cd in deg. Column A Column B Column C Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP vertical horizontal min max min max min max BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 4.40∙102 -- 6.10∙102 - 6.95∙102 Line 1 and Line 4 of Table 32 have III b 0.34°U 4°L to be measured. In the case where the passing beam, which meets the requirements of 5.3.6.2 is continuously operated in conjunction with the adaptation of the driving beam, the photometric requirements in Part B Table 32 shall not be applied. 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 6.80∙103 - 5.44∙103 - 4.76∙103 - 50V 0.86°D 0° 1.01∙104 - 8.08∙103 - 7.07∙103 -
Table 33changed
Passing-beam Class AS Required luminous Test point / line / zone Angular coordinates - degrees* Luminous intensity in cd Any point in Zone 1 deg. Column A Column B Column C Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP vertical horizontal min max min max min max BR 1°U 2.5°R - 1.75∙103 - 2.10∙103 - 2.28∙103 Point BLL 0.57°U 8°L - 8.80∙102 - 1.14∙103 - 1.26∙103 B50L 0.57°U 3.43°L - 3.50∙102 - 5.20∙102 - 6.05∙102 Line III b 0.34°U 4°L to 0.5°L - 8.80∙102 - 1.14∙103 - 1.26∙103 75R 0.57°D 1.15°R 1.52∙104 - 1.22∙104 - 1.06∙104 - 50L 0.86°D 3.43°L 6.80∙103 - 5.44∙103 - 4.76∙103 - 50V 0.86°D 0° to 15°U 5°L to 5°R ≤ 320 cd Any point on line 25L to 25R 1.72°D 5°L to 5°R ≥ 1,100 cd Any point on line 12.5L to 12.5R 3.43°D 5°L to 5°R ≥ 550 cd Note to Table 33 * 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. 1.01∙104 - 8.08∙103 - 7.07∙103 -
5.6.1.1.deleted
For the left-hand device, the minimum intensity of the light at the specified measuring points shall be as follows: (a) 2.5D – 30L: 240 cd (b) 2.5D – 45L: 400 cd (c) 2.5D – 60L: 240 cd The same values apply symmetrically for a right-hand device. (Shown in Annex 4 Figure A4-XII)
5.6.1.2.deleted
The intensity of the light emitted in all directions shall not exceed: (a) 300 cd above the 1.0U, L and R line; (b) 600 cd between the horizontal plane and the 1.0U, L and R Line; and (c) 14,000 cd below the 0.57 D, L and R line.
6.2.1.1.4.2.1.added
If there is more than one mode of the driving-beam only the mode corresponding to the neutral state shall be tested for CoP according to Table 34. 6.2.1.1.4.2.1.1. Driving-beam –bending mode –if applicable: If the system uses the same functional units to obtain bending modes for more than one class, no further testing of the bending modes of Category 1 and/or Category 2 is necessary. If not, the system shall be tested according to Table 35.
5.6.1.3.deleted
In the case of a single lamp containing more than one light source when all light sources are illuminated the maximum intensities shall not be exceeded.
6.2.1.1.4.2.2.added
Adaptive Driving-beam–if applicable: During adaptation, the driving-beam function shall meet the requirements for all the cases of Right-Hand and/or Left-Hand traffic specified in Part A of
5.6.1.4.deleted
Failure of a single lamp containing more than one light source:
Table 36changed
Vertical position* Horizontal position* Designated lines or above h + left If the system uses the same functional units for the adaptation of v: - Luminous intensity zones below h - right of v: + (in cd) To comply Point 1, 2** +60° ±45° Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° 85 max All points Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° the driving- beam only Line 1** +8° -26° to +26° 130 max All line Line 2** +4° -26° to +26° 150 max All line Vertical position* Horizontal position* Designated lines or above h + left of v: - Luminous intensity zones below h - right of v: + (in cd) To comply Line 3 +2° -26° to +26° 245 max All line 1 and Line 4 +1° -26° to +26° 360 max All line Line 5 0° -10° to +10° 485 max All line Line 6 *** -2.5° -10° to +10° 2700 min All line < 50 per cent of Line 7 *** -6.0° -10° to +10° max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 min One or more points Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 max Whole zone Notes to Table 36 * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 5.5.2.4. *** See paragraph 5.5.2.2. have to be measured.
5.6.1.4.1.deleted
In a single lamp containing more than one light source, a group of light sources, wired so that the failure of any one of them causes all of them to stop emitting light, shall be considered to be one light source.
Table 34changed
Required Test/point/ luminous intensity line/zone Angular coordinates - degrees* Luminous intensity in cd Any point in Zone 1 0°to 15°U 5°L to 5°R ≤ 700 cd Any point on line 50L to 50R except 50V 0.86°D 2.5°L to 2.5°R ≥ 1,100 cd Point 50V 0.86°D 0 ≥ 2,200 cd Any point on line 25L to 25R 1.72°D 5°L to 5°R ≥ 2,200 cd Any point in Zone 2 0.86°D to 1.72°D 5°L to 5°R ≥ 1,100 cd Note to Table 34 * 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. deg. Column A Column B Column C Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP vertical horizontal min max min max min max 2U-V 2°U 0° 1.70∙103 1.30∙103 1.10∙103 H-12L 0° 12°L 1.50∙103 1.20∙103 1.00∙103 H-9L 0° 9°L 3.40∙103 2.70∙103 2.30∙103 H-6L 0° 6°L 5.00∙103 4.00∙103 3.50∙103 H-3L 0° 3°L 1.75∙104 1.40∙104 1.22∙104 2.15∙105 2.58∙105 2.80∙105 H-V 0° 0° 3.20∙104 2.56∙104 2.24∙104 H-3R 0° 3°R 1.75∙104 1.40∙104 1.22∙104 H-6R 0° 6°R 5.00∙103 4.00∙103 3.50∙103 H-9R 0° 9°R 3.40∙103 2.70∙103 2.30∙103 H-12R 0° 12°R 1.50∙103 1.20∙103 1.00∙103
5.6.1.4.2.deleted
In case of failure of any one light source in a single lamp containing more than one light source, at least one of the following provisions shall apply: (a) The light intensity complies with the minimum intensity required in the table of standard light distribution in space as shown in Annex 4, Figure L; or (b) A signal for activation of a tell-tale indicating failure, as indicated in paragraph 6.20.8. of Regulation No. 48, is produced, provided that the luminous intensity at 2.5°D 45°L for a left-side lamp (the L angle should be substituted for the R angle for a right-side lamp) is at least 50 per cent of the minimum intensity required. In this case a note in the communication form states that the lamp is only for use on a vehicle fitted with a tell-tale indicating failure.
Table 35changed
Required luminous Angular coordinates Luminous intensity in cd Test point / Test point angular in deg. Column A Column B Column C Element ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP vertical horizontal min max min max min max 2U-V 2°U 0° 1.30∙103 1.08∙103 9.50∙102 H-12L 0° 12°L 1.20∙103 9.60∙102 8.40∙102 H-9L 0° 9°L 2.70∙103 2.17∙103 1.90∙103 H-6L 0° 6°L 4.00∙103 3.20∙103 2.80∙103 H-3L 0° 3°L 1.40∙104 1.12∙104 9.80∙103 2.15∙105 2.58∙105 2.80∙105 H-V 0° 0° 3.20∙104 2.56∙104 2.24∙104 H-3R 0° 3°R 1.40∙104 1.12∙104 9.80∙103 H-6R 0° 6°R 4.00∙103 3.20∙103 2.80∙103 H-9R 0° 9°R 2.70∙103 2.17∙103 1.90∙103 H-12R 0° 12°R 1.20∙103 9.60∙102 8.40∙102 Class R – Adaptive Driving-beam – System Requirements Max. luminous intensity b in cd Angular coordinates line / zone degrees* Minimum Maximum Class Class Classes Class ES CS DS CS, DS, ES 1 0.86°D 3.5°R 2,000 2,000 2,500 13,750 2 0.86°D 0 2,450 4,900 4,900 - 3 0.86°D 3.5°L 2,000 2,000 2,500 13,750 4 0.50°U 1.50°L and 1.50°R -- -- -- 900 5 2.00°D 15°L and 15°R 550 1,100 1,100 -- 6 4.00°D 20°L and 20°R 150 300 600 - 7 0 0 -- -- -- 1,700 in deg Element Column A Column B Column C vertical horizontal ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP Line 1 2.00°D 9°L Left Oncoming vehicle at 50 m in the case 0.57°U 4.8°L to 9°R 1,350 1,350 1,900 - 8** 4.00°U 8.0°L 700 9** 4.00°U 0 ∑ 8 + 9 + 10 ≧ 150 2°L 6.25∙102 8.80∙102 1.00∙103 of Right-Hand Traffic Line 1 Right Oncoming vehicle at 50 m in the case 0.57°U 2°R to 4.8°R 6.25∙102 8.80∙102 1.00∙103 of Left-Hand Traffic Line 2 Left Oncoming vehicle at 100 m in the case 0.3°U 2.4°L to 1°L 1.75∙103 2.10∙103 2.28∙103 of Right-Hand Traffic Line 2 Right Oncoming vehicle at 100 m in the case 0.3°U 1°R to 2.4°R 1.75∙103 2.10∙103 2.28∙103 of Left-Hand Traffic Line 3 Left Oncoming vehicle at 200 m in the case 0.15°U 1.2°L to 0.5°L 5.45∙103 6.54∙103 7.09∙103 of Right-Hand Traffic Part A Line 3 Right Oncoming vehicle at 200 m in the case 0.15°U 0.5°R to 1.2°R 5.45∙103 6.54∙103 7.09∙103 of Left-Hand Traffic Line 4 1.7°L to 1.0°R 1.85∙103 2.22∙103 2.41∙103 Preceding vehicle at 50 m in the case of Right-Hand Traffic > 1.0°R to 1.7°R 2.50∙103 3.00∙103 3.25∙103 0.3°U Line 4 1.7°R to 1.0°L 1.85∙103 2.22∙103 2.41∙103 Preceding vehicle at 50 m in the case of Left-Hand Traffic > 1.0°L to 1.7°L 2.50∙103 3.00∙103 3.25∙103 Line 5 0.9°L to 0.5°R 5.30∙103 6.36∙103 6.89∙103 Preceding vehicle at 100 m in the case of Right-Hand Traffic > 0.5°R to 0.9°R 7.00∙103 8.40∙103 9.10∙103 0.15°U Line 5 0.9°R to 0.5°L 5.30∙103 6.36∙103 6.89∙103 Preceding vehicle at 100 m in the case of Left-Hand Traffic > 0.5°L to 0.9°L 7.00∙103 8.40∙103 9.10∙103 Line 6 Preceding vehicle at 200 m in the case 0.1°U 0.45°L to 0.45°R 1.60∙104 1.92∙104 2.08∙104 of Left-Hand Traffic and Right-Hand Traffic Angular coordinates Max. luminous intensity b in cd ** 700 10** 4.00°U 8.0°R 700 11** 2.00°U 4.0°L 900 12** 2.00°U 0 ∑ 11 + 12 + 13 ≧ 300 cd ** 900 13** 2.00°U 4.0°R 900 14** 0 8.0°L and 8.0°R 50 cd** 50 cd** 50 cd** - 15** 0 4.0°L and 4.0°R 100 cd** 100 cd** 100 cd** 900 1°U/8°L-4°U/8°L-4°U/8°R- Zone 1 1°U/8°R-0/4°R-0/1°R-0.6°U/0- -- -- -- 900 0/1°L-0/4°L-1°U/8°L >4U a in deg. Element Column A Column B Column C vertical horizontal ≙ 0% CoP ≙ 20% CoP ≙ 30% CoP Part B 50L 0.86°D 3.43°L 2.55∙103 2.04∙103 1.79∙103 50V 0.86°D 0° 5.10∙103 4.08∙103 3.57∙103 50R 0.86°D 1.72°R 5.10∙103 4.08∙103 3.57∙103 25LL 1.72°D 16°L 1.18∙103 9.44∙102 8.26∙102 25RR 1.72°D 11°R 1.18∙103 9.44∙102 8.26∙102 Notes: In Table 36 a Angular positions are indicated for right-hand traffic. b The photometric requirements for each single measuring point (angular position) of this lighting function apply to Zone 2 8°L to 8°R -- -- -- 700 <15 U Notes to Table 35 * 0.25 tolerance allowed independently at each test point for photometry unless indicated otherwise. ** On request half of the applicant during measurement sum of these points, the front position lamp approved respective measured values from all lighting units of the system applied for this function. In case of class ADB for vehicle of category L3, not being part of a matched pair, this provision does not apply. Each of the lines defined in Part A of Table 36, in conjunction with the test points as prescribed in Part B of Table 36 shall be measured individually corresponding to UN Regulation No. 50, UN Regulation No. 7 or UN Regulation No. 148; if combined, grouped, or reciprocally incorporated-shall the signal provided by the signal generator. In the case where the passing-beam, which meets the requirements of paragraph 6.2.1.1.4.1, is continuously operated in conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of Table 36 shall not be switched ON. applied. For vehicles of category L3, in the case where the passing-beam, which meets the requirements of paragraph 5.4.3.3. as specified in Annex 2, is continuously operated in conjunction with the adaptation of the driving-beam, the photometric requirements in Part B of Table 36 shall not be applied.
6.2.1.1.4.3.added
If the results of the test described above do not meet the requirements, the alignment of the AFS may be changed according to the provisions in Annex 5, paragraph 4.1.
5.6.2.1.deleted
When photometric measurements are taken, stray reflections shall be avoided by appropriate masking.
6.2.1.1.4.4.added
As an alternative to the re-alignment procedure as described in paragraph 4.1. of Annex 5, the intensity requirement of column A, B or C of Tables 23 to 38 for a particular direction of observation shall be deemed to be satisfied if that requirement is met in a direction deviating by not more than one-quarter of a degree from the direction of observation.
5.6.2.2.deleted
In the event that the results of measurements are challenged, measurements shall be taken in such a way as to meet the following requirements:
6.3.added
With respect to the verification of the change in vertical position of the cut-off line under the influence of heat, the following procedure shall be applied: One of the sampled lamps or systems shall be tested according to the procedure described in paragraph 3.1. of Annex 7 after being subjected three consecutive times to the cycle described in paragraph 3.2.2. of Annex 7 A headlamp or system shall be considered as acceptable if r does not exceed 1.5 mrad upwards and does not exceed 2.5 mrad downwards. If this value exceeds 1.5 mrad but is not more than 2.0 mrad upwards or exceeds 2.5 mrad but is not more than 3.0 mrad downwards, a second sample shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards. However, if this value of 1.5 mrad upwards and 2.5 mrad downwards on these two systems is not complied with, another two systems shall be subjected to the same procedure and the value of r for each of them shall not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards. A front fog lamp shall be considered as acceptable if r does not exceed 3.0 mrad. If this value exceeds 3.0 mrad but is not more than 4.0 mrad, a second front fog lamp shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 3.0 mrad.
5.6.2.2.1.deleted
The distance of measurement shall be such that the law of the inverse of the square of the distance is applicable;
6.4.added
The chromaticity coordinates shall be complied with.
5.6.2.2.2.deleted
The measuring equipment shall be such that the angle subtended by the receiver from the reference centre of the light is between 10′ and 1°;
5.6.2.2.3.deleted
The intensity requirement for a particular direction of observation shall be satisfied if the required intensity is obtained in a direction deviating by not more than one quarter of a degree from the direction of observation.
5.6.2.3.deleted
Measuring points expressed in degrees of angle with the axis of reference are shown in Annex 4, Figure A4-XII. The values shown in the table give, for the various directions of measurement, the minimum intensities in cd.
7.1.1.added
Contracting Parties applying this Regulation shall continue to accept type approvals of the lamps (functions), to any of the preceding series of amendments to this Regulation, which are not affected by the changes introduced by the latest series of amendments. To verify this, the change index applicable to the pertinent lamp (function) shall not differ from its change index as indicated in the latest series of amendments.
5.6.2.4.deleted
Horizontal and vertical angles for the field of geometric visibility are shown in Annex 4, Figures A4-XIII. The directions H = 0° and V = 0° correspond to the axis of reference. On the vehicle they are horizontal, parallel to the median longitudinal plane of the vehicle and oriented in the required direction of visibility. They pass through the centre of reference.
7.1.2.added
Contracting Parties applying this Regulation shall not refuse to grant extensions to type approvals according to any preceding series of amendments to this Regulation.
7.2.1.added
As from the official date of entry into force of the 01 series of amendments, no Contracting Party applying this Regulation shall refuse to grant or refuse to accept UN type approvals under this Regulation as amended by the 01 series of amendments.
7.2.2.added
As from 1 September 2026 Contracting Parties applying this Regulation shall not be obliged to accept UN type approvals to the preceding series of amendments, first issued after 1 September 2026.
5.6.3.3.deleted
For any cornering lamp except those equipped with filament light source(s), the luminous intensities, measured after one minute and after 10 minutes of operation, shall comply with the minimum and maximum requirements. The luminous intensity distributions after one and after 10 minutes of operation shall be calculated from the luminous intensity distribution measured after photometric stability has occurred by applying at each test point the ratio of luminous intensities measured at 45°L 2.5°D for a left-side lamp (the L angle should be substituted for the R angle for a right-side lamp): (a) After one minute; (b) After 10 minutes; and (c) After photometric stability has occurred. Photometric stability has occurred means the variation of the luminous intensity for the specified test point is less than 3 per cent within any 15 minute period.
7.2.3.added
Contracting Parties applying this Regulation shall continue to accept type approvals to the preceding series of amendments to this Regulation, first issued before 1 September 2026.
7.2.4.added
Contracting Parties applying this Regulation shall continue to grant and accept type approvals for devices (equipment and parts) on the basis of any previous series of amendments, provided that the devices (equipment and parts) are intended as replacements for fitting to vehicles in use and that it is not technically feasible for the devices (equipment and parts) in question to satisfy the new requirements contained in this Regulation as amended by the 01 series of amendments.
7.2.5.added
Notwithstanding the transitional provisions above, Contracting Parties whose application of this Regulation comes into force after the date of entry into force of the 01 series of amendments are not obliged to accept UN type approvals which were granted in accordance with any of the preceding series of amendments to this Regulation.
7.2.6.added
Contracting Parties applying this Regulation shall continue to accept UN type approvals to the preceding series of amendments to this Regulation, for the equipment or parts which are not affected by the changes introduced by the 01 series of amendments.
7.2.7.added
Contracting Parties applying this Regulation shall not refuse to grant type approvals according to any preceding series of amendments to this Regulation or extensions thereof.
Annex 1changed
(Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of device or system pursuant to UN Regulation No. 149 Class of the device: lamp (function): ……… Change index: ………. Approval No. ……………………………. Unique Identifier (UI) (If applicable): … …
9.changed
Brief description: 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the regulation). 2 Strike out what does not apply. Annex 1
9.1.added
For passing-beam headlamps of Classes C and V and driving-beam headlamps of Classes A, B and RA The driving-beam of Class RA (auxiliary driving-beam) shall only be operated together with driving-beams of Classes A, B or AFS-R . 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the regulation). 2 Strike out what does not apply. 3 Indicate the appropriate marking(s) based on the symbols listed on Table 1 combined with the relevant additional symbol(s) described in paragraph 3.3.2.4. if any (examples are provided in Annex 13).
9.1.6.added
Number and specific identification code(s) of light source module(s) and for
9.1.8.changed
Total objective luminous flux as described in paragraph 4.5.6. 4.5.3.5. of this Regulation exceeds 2,000 2.00∙103 lumens: yes/no/does not apply1 apply2
9.1.9.changed
The determination of the minimum sharpness of the "cut-off" has been carried out at: 10 m/25 m/does not apply1 apply2
9.2.2.deleted
The passing beam light source may/may not1 be lit simultaneously with the driving beam light source and/or another reciprocally incorporated headlamp. 3 Indicate the appropriate marking selected from the list below: C, C, C , R, R PL, CR, CR, CR , C/R, C/R, C/R , C/ , C/ , C/ , C, PL, C PL, C PL, CR PL, CR PL, CR PL, C/R PL, C/R PL, C/R PL, C/PL, C/PL, C/PL HC, HC, HC , HR, HR PL, HCR, HCR, HCR, HC/R, HC/R, HC/R, HC/, HC/, HC/, HC PL, HC PL, HC PL, HCR PL, HCR PL, HCR PL, HC/R PL, HC/R PL, HC/R PL, HC/PL, HC/PL, HC/PL 4 Indicate the appropriate marking selected from the list below: DC, DC/, DC/PL, DR, DCR, DC/R, DC PL, DR PL, DCR DC/R DC, DCR, DC/R, DC/, DC PL, DCR PL, DC/R DC/PL, PL, PL, PL, DC, DCR, DC/R, DC/, DC PL, DCR PL, DC/R DC/PL, PL,
9.1.10.added
Trade name and identification number of separate ballast(s) or part(s) of
9.2.4.1.deleted
If more than one objective luminous flux value is specified:
9.2.4.2.deleted
If more than one objective luminous flux value is specified:
9.1.12.added
The light source(s) producing the principal passing beam may be lit simultaneously with that of any other lighting function in the same body: yes/no2
9.2.2.1.added
Number and specific identification code(s) of light source module(s) and for each light source module a statement whether it is replaceable or not: yes/no 2
9.2.2.3.added
Total objective luminous flux as described in paragraph 4.5.3.6. of this Regulation exceeds 2.00∙103 lumens: yes/no2
9.3.2.1.deleted
Number and specific identification code(s) of LED module(s) and for each LED module a statement whether it is replaceable or not: yes/no1
9.2.3.added
(a) Indications according to paragraph 5.3.5.1. of this Regulation (which lighting unit(s) provide a "cut-off" as defined in Annex 5 of this Regulation, that projects into a zone extending from 6 degrees left to 4 degrees right and (b) The adjustment of the "cut-off" has been determined at 10 m / 25 m.2 4 Indicate the appropriate marking as foreseen according to this Regulation for each installation unit or assembly of installation units. (c) The determination of the minimum sharpness of the "cut-off" has been carried out at 10 m / 25 m.2
9.2.5.changed
Trade name and identification number Whether approval is sought for an AFS or ADB which is not intended to be included as part of separate ballast(s) the approval of a vehicle type according to UN Regulation No. 48 or part(s) of UN Regulation No. 53: yes/no 2
9.3.2.3.deleted
Total objective luminous flux as described in paragraph 4.5.2.6. of this Regulation exceeds 2,000 lumen: yes/no1
9.2.5.1.added
If in the affirmative: information sufficient to identify the vehicle(s) for which
9.3.3.deleted
(a) Indications according to paragraph 5.3.5.1. of this Regulation (which lighting unit(s) provide a "cut-off" as defined in Annex 5 of this Regulation, that projects into a zone extending from 6 degrees left to 4 degrees right and (b) The adjustment of the "cut-off" has been determined at 10 m / 25 m1 (c) The determination of the minimum sharpness of the "cut-off" has been carried out at 10 m / 25 m1
9.2.6.changed
The determination Indications according to paragraph 5.3.5.2. of the minimum sharpness this Regulation (which class E passing-beam mode(s), if any, comply with a "data set" of the "cut-off" has been carried out at 10 m/25 m. 1 Table 12 of this
9.3.5.deleted
Whether approval is sought for a system which is not intended to be included as part of the approval of a vehicle type according to UN Regulation No. 48: yes/no1
9.2.7.added
Whether approval is sought for a system intended to be installed on vehicles only, which provide means for a stabilization/limitation of the system's supply: yes/no2
9.3.5.1.deleted
If in the affirmative: information sufficient to identify the vehicle(s) for which 5 Indicate the appropriate marking as foreseen according to this Regulation for each installation unit or assembly of installation units. Annex 1
9.2.8.changed
Distributed lighting system with one common gas-discharge light source: Yes/No1 The determination of the minimum sharpness of the "cut-off" has been carried out at 10 m / 25 m. 2
9.3.8.deleted
The determination of the minimum sharpness of the "cut-off" has been carried out at 10 m / 25 m. 1
9.2.9.2.added
Mode No. C 1 Mode No. V … Mode No. E … Mode No. W … Mode No. C … Mode No. V … Mode No. E … Mode No. W … Mode No. C … Mode No. V … Mode No. E … Mode No. W … (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (b) If bend lighting of category 1 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (c) if bend lighting of category 2 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  Note: Indications according to paragraph (a) through (c) above are needed additionally for each further mode.
9.2.9.4.added
The lighting units marked below are energized, when the system is in its neutral state5, 7 Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12 
9.2.9.5.added
The lighting units marked below are energized, when the system is in its traffic change function5, 6, 7 5 Mark with an X where applicable. 6 To be extended if more modes are provided. 7 To be continued if more units are provided. (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (b) If bend lighting of category 1 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (c) If bend lighting of category 2 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  5, 6, 7
9.3.9.2.deleted
Mode No. C 1 Mode No. V … Mode No. E … Mode No. W … Mode No. C … Mode No. V … Mode No. E … Mode No. W … Mode No. C … Mode No. V … Mode No. E … Mode No. W … (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (b) If bend lighting of category 1 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (c) if bend lighting of category 2 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  Note: Indications according to paragraph (a) through (c) above are needed additionally for each further mode.
9.2.10.added
The system is designed to provide a main beam :
9.3.9.4.deleted
The lighting units marked below are energized, when the system is in its neutral state5, 7 Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12 
9.3.9.5.deleted
The lighting units marked below are energized, when the system is in its traffic change function5, 6, 7 (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  6 Mark with an X where applicable. 7 To be extended if more modes are provided. 8 To be continued if more units are provided. (b) If bend lighting of category 1 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (c) If bend lighting of category 2 applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  5, 6, 7
9.2.10.2.added
With the following mode(s), identified by the designation(s), if it applies: Main beam mode No. M 1 Main beam mode No. M … Main beam mode No. M … (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (b) If bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  Note: Indications according to this paragraph (a) through (b) above are needed additionally for each further mode.
9.3.10.deleted
The system is designed to provide a main beam :
9.2.10.4.added
The lighting units marked below are energized, when the system is in its neutral state5 Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12 
9.2.10.5.added
The system is designed to provide an adaptation of the driving-beam for: Right-Hand and Left-Hand traffic: yes  no  Right-Hand traffic only: yes  no  Left-Hand traffic only: yes  no 
9.3.10.2.deleted
With the following mode(s), identified by the designation(s), if it applies: Main beam mode No. M 1 Main beam mode No. M … Main beam mode No. M … (a) If no bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  (b) If bend lighting applies: Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12  Note: Indications according to this paragraph (a) through (b) above are needed additionally for each further mode.
9.2.10.6.added
ADB system intended to be included as part of the approval of a vehicle type of category L3 according to UN Regulation No. 53: yes/no2
9.3.10.4.deleted
The lighting units marked below are energized, when the system is in its neutral state6,8 Left side No.1  No.3  No.5  No.7  No. 9  No.11  Right side No.2  No.4  No.6  No.8  No.10  No.12 
9.3.10.5.deleted
The system is designed to provide an adaptation of the driving beam for: Right-Hand and Left-Hand traffic: yes  no  Right-Hand traffic only: yes  no  Left-Hand traffic only: yes  no 
9.2.12.added
The light source(s) producing the principal passing beam may be lit simultaneously with that of any other lighting function in the same body: yes/no 2
9.4.deleted
9 Indicate the appropriate marking selected from the list below: C-AS, C- BS, R- BS, CR- BS, C/ -BS, C/R-BS, C-BS PL, R-BS PL, CR-BS PL, C/ -BS PL, C/R-BS PL, WC-CS, WC-DS, WR-CS WR-DS, WCR-CS, WCR-DS, WC/-CS, WC/-DS, WC/R-CS, WC/R-DS, WC-CS PL, WC-DS PL, WR-CS PL, WR-DS PL, WCR-CS PL, WCR-DS PL, Annex 1
9.4.6.deleted
Trade name and identification number of separate ballast(s) or part(s) of
9.3.6.changed
Indications according to paragraph 5.3.5.2. Trade name and identification number of this Regulation (which class E passing beam mode(s), if any, comply with a "data set" separate ballast(s) or part(s) of Table 14 of this
9.3.7.changed
Whether approval is sought for a system intended to The light source(s) producing the principal passing beam may be installed on vehicles only, which provide means for a stabilization/limitation lit simultaneously with that of any other lighting function in the system's supply: yes/no1 same body: yes/no 2
9.4.9.deleted
Secondary Driving Beam: yes / no1 The Secondary Driving Beam shall only be operated together with a passing beam or a primary driving beam.
9.3.9.added
Secondary Driving-beam of Class CS or Class DS: yes/no2 The Secondary Driving-beam shall only be operated together with a passing- beam or a driving-beam of Class A or Class B.
9.5.1.deleted
Class as described by the relevant marking: 9.5.3 LED module: yes/no1 and for each LED module a statement whether it is replaceable or not: yes/no1
9.4.1.1.added
9.4.3 light source module: yes/no2 and for each light source module a statement whether it is replaceable or not: yes/no2
9.4.7.changed
The passing beam Luminous flux of the light source may/may not1 be lit simultaneously with the driving beam light source and/or another reciprocally incorporated headlamp. (see paragraph 4.5.3.4. of this Regulation) greater than 2.00∙103 lumens: … yes/no2
9.6.5.deleted
Application of an electronic light source control gear:
9.6.7.deleted
Electronic light source control gear manufacturer and identification number (when the light source control gear is part of the lamp but is not included into the lamp body):
9.4.11.added
The light source(s) producing the front fog lamp may be lit simultaneously with that of any other lighting function in the same body: yes/no2
9.5.5.changed
In the case Application of an electronic light source control gear not being part of the lamp: WC/CS PL, WC/-DS PL, WC/R-CS PL, WC/R-DS PL, WC+-CS, WC+-DS, WC+R-CS, WC+R-DS, C+-BS, C+R-BS, WC+-CS PL, WC+-DS PL, WC+R-CS PL, WC+R-DS PL, C+-BS PL, C+R-BS PL WC-ES, WR-ES, WCR-ES, WC/-ES, WC/R-ES, WC-ES PL, WR-ES PL, WCR-ES PL, WC/-ES PL, WC/R-ES PL WC+-ES, WC+R-ES, WC+-ES PL, WC+R-ES PL 10 The voltage specifications shall include the tolerances or voltage range as specified by the manufacturer and verified by this approval. 11 The parameters of the input voltage including duty cycle, frequency, pulse shape and peak voltage shall be included. gear:
9.5.7.changed
Luminous flux Electronic light source control gear manufacturer and identification number (when the electronic light source control gear is part of the light source (see paragraph 4.5.2.6.) greater than 2,000 lumens: … yes/no1 lamp but is not included into the lamp body):
9.6.added
Whether an additional test is conducted according to the paragraph 4.19. of this Regulation: yes/no2
1.2.1.deleted
No measured value deviates unfavourably by more than 20 per cent from the value prescribed in this Regulation.
1.2.1.1.deleted
For class A, B and D headlamps corresponding to paragraphs 5.2. of this Regulation for the values B 50 L (or R) and zone III, the maximum unfavourable deviation may be respectively: B 50 L (or R): 170 cd equivalent 20 per cent 255 cd equivalent 30 per cent Zone III: 255 cd equivalent 20 per cent 380 cd equivalent 30 per cent
16.changed
The list of documents deposited with the Type Approval Authority, which has granted approval is annexed to this communication and may be obtained on request. 12 8 For cornering lamps with non-replaceable light sources indicate the number and total wattage of the light sources used. Annex 2
1.2.1.2.deleted
For AFS corresponding to paragraph 5.3. of this Regulation no value measured and corrected according to the prescriptions of paragraph 4.6. to this Regulation, deviates unfavourably from the value prescribed in column B of the Tables 17 to 32, if applicable.
1.2.1.3.deleted
For class BS, CS, DS and ES headlamps corresponding to paragraph 5.4. of this Regulation for values in zone I, the maximum unfavourable deviation may be respectively: Zone I: 255 cd equivalent 20 per cent 380 cd equivalent 30 per cent
1.2.1.3.1.deleted
If the results of the test described above do not meet the requirements, the alignment of the headlamp may be changed, provided that the axis of the beam is not displaced laterally by more than 0.5 degree, to the right or left and not by more than 0.2 degree up and down.
1.1.changed
The conformity requirements shall be considered satisfied from a mechanical and a geometric standpoint, in accordance with the requirements of this Regulation, if any, if the differences do not exceed inevitable manufacturing deviations within the requirements of this Regulation. This condition also applies to colour. deviations.
1.2.1.4.deleted
37 shall apply;
1.2.changed
With respect to photometric performances, the conformity of mass-produced lamps shall not be contested if, when testing photometric performances of any lamp chosen at random and equipped with a standard (étalon) light source and/or non-replaceable light source(s) and/or LED light source module(s), as present in the lamp; lamp: (a) No measured value deviates from the values prescribed in paragraph 6 of this Regulation; (b) If, in the case of a lamp equipped with a replaceable light source and if results of the test described above do not meet the requirements, tests on lamps shall be repeated using another standard light source.
1.2.2.deleted
or, in case of class A, B or D headlamps corresponding to paragraph 5.2. of this Regulation, if
1.3.changed
With respect to If the verification results of the change in vertical position test described above do not meet the requirements, the alignment of the cut-off line under the influence of heat, the following procedure shall lamp may be applied: One of the sampled lamps or systems shall be tested changed according to the procedure described provisions in Annex 5, paragraph 3.1. of Annex 7 after being subjected three consecutive times to the cycle described in paragraph 3.2.2. of Annex 7 A headlamp or system shall be considered as acceptable if r does not exceed 1.5 mrad upwards and does not exceed 2.5 mrad downwards. If this value exceeds 1.5 mrad but is not more than 2.0 mrad upwards or exceeds 2.5 mrad but is not more than 3.0 mrad downwards, a second sample shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards. However, if this value of 1.5 mrad upwards and 2.5 mrad downwards on these two systems is not complied with, another two systems shall be subjected to the same procedure and the value of r for each of them shall not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards. A front fog lamp shall be considered as acceptable if r does not exceed 3.0 mrad. If this value exceeds 3.0 mrad but is not more than 4.0 mrad, a second front fog lamp shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 3.0 mrad. 4.1.
1.2.2.1.deleted
For the passing-beam, the values prescribed in this Regulation are met at one point within a circle of 0.35 degrees around points: in case of class A or B headlamps B 50 L (or R) (with a tolerance of 85 cd), 75 R (or L), 50 V, 25 R, 25 L, and in the entire area of zone IV which is not more than 0.52 degrees above line 25 R and 25 L; in case of class D headlamps B 50 L (or R) (with a tolerance of 85 cd), 75 R (or L), 50 V, 25 R1, 25 L2, and on segment I;
1.4.changed
If, however, vertical adjustment cannot For AFS corresponding to paragraph 5.3. of this Regulation, if the results of the test described above do not meet the requirements, the alignment of the system may be performed repeatedly changed in each class according to the required position within the tolerances described provisions in Annex 5, paragraph 1.2.3. of Annex 5 or 4.1. These provisions do not apply to lighting units as indicated under paragraph 3.2. of Annex 6 respectively, one sample shall be tested according Annex 2 to the procedure described in paragraph 2. of Annex 5 or paragraph 4. of Annex 6 respectively.
1.2.2.2.deleted
and if, for the driving beam, HV being situated within the isocandela 0.75 Imax a tolerance of + 20 per cent for maximum values and -20 per cent for minimum values is observed for the photometric values at any measuring point specified in paragraph 5.1. of this Regulation.
1.2.2.3.deleted
If the results of the test described above do not meet the requirements, the alignment of the headlamp may be changed, provided that the axis of the beam is not displaced laterally by more than 0.5 degree to the right or left and not by more than 0.2 degree up and down.
1.5.added
Lamps with apparent defects are disregarded.
1.2.3.deleted
For AFS corresponding to paragraph 5.3. of this Regulation, if the results of the test described above do not meet the requirements, the alignment of the system may be changed in each class, provided that the axis of the beam is not displaced laterally by more than 0.5 degree to the right or left and not by more than 0.2 degree up and down, each independently and with respect to the first aiming. These provisions do not apply to lighting units as indicated under paragraph
1.2.4.deleted
If in the case of a lamp equipped with a replaceable light source the results of the tests described above do not meet the requirements, tests shall be repeated using another standard (étalon) light source.
1.5.1.deleted
With respect to photometric performances, the conformity of mass-produced lamps shall not be contested if, when testing photometric performances of any lamp chosen at random and equipped with a standard light source, or when the lamps are equipped with non-replaceable light sources (filament light sources or other), and when all measurements are made at 6.75 V, 13.5 V or 28.0 V respectively:
1.5.1.1.deleted
No measured value deviates unfavourably by more than 20 per cent from the values prescribed in this Regulation.
1.5.1.2.deleted
If, in the case of a lamp equipped with a replaceable light source and if results of the test described above do not meet the requirements, tests on lamps shall be repeated using another standard light source.
1.5.2.deleted
The chromaticity coordinates shall be complied with when the lamp is equipped with a standard light source, or for lamps equipped with non- replaceable light sources (filament light sources or other), when the colorimetric characteristics are verified with the light source present in the lamp. 1.5.3 In the case of non-replaceable filament light source(s) or light source module(s) equipped with non-replaceable filament light sources, at any conformity of production check: 1.5.3.1 the holder of the approval mark shall demonstrate the use in normal production and show the identification of the non-replaceable filament light source(s) as indicated in the type approval documentation;
1.5.3.2.deleted
in the case where doubt exists in respect to compliance of the non-replaceable filament light source(s) with lifetime requirements and/or, in the case of colour coated filament light sources, with colour endurance requirements, as specified in paragraph 4.11 of IEC 60809, Edition 3, conformity shall be checked as specified in paragraph 4.11 of IEC 60809, Edition 3.
2.4.1.1.changed
For driving-beam headlamps of Classes A and B according to paragraph 5.1. and / or passing- beam passing-beam headlamps (asymmetrical) of Classes C, V and AFS according to paragraph paragraphs 5.2. and 5.3 of this Regulation apply: to the points Imax, HV1, H-3L, H-3R in the case of a driving-beam, and to points B50L (or R), 50L (or R), 50V, 75R (or L) if applicable and 40R (or L) in the case of the passing- beam(s).
1.6.deleted
The chromaticity coordinates shall be complied with.
5.1.added
and / or passing-beam headlamps (symmetrical cut-off) according to paragraph 5.4. of this Regulation:
2.4.1.2.1.changed
For Class AS headlamps to the points HV, LH, RH, 12.5L 3.43°D/5°L and 12.5R. 3.43°D/5°R.
2.4.1.2.2.changed
For Class BS headlamps to the points I max Imax and HV1 in the case of the driving driving- beam, and to the points HV, 0.86D/3.5R, 0.86D/3.5L in the case of the passing beam. 1 When the driving-beam is reciprocally incorporated with the passing-beam, HV in the case of the driving-beam shall be the same measuring point as 0.86°D/2.5°R, 0.86°D/2.5°L in the case of the passing-beam. 2 HL and HR: points on HH located at 2.5 degrees to the left and to the right of point HV respectively. Annex 2
2.4.1.2.3.changed
For Classes CS, CS and DS and ES headlamps to the points Imax and HV1 HV in the case of the driving beam, driving-beam, and to the points HV, 0.86D/3.5R, 0.86D/3.5L point 0.86°D/V in the case of the passing beam. passing-beam.
2.4.1.3.changed
For AFS according to paragraph 5.3. to this Regulation, to 8 and 9, and the points Imax, HV1, HL lines 1, 5, 6, 8 and HR3 9 as specified in the case of a driving-beam and to points B50L, HV if applicable, 50V, 75R if applicable, and 25LL in the case of the passing- beam(s). Table 19.
2.4.2.changed
For cornering lamps according to paragraph 5.6. of this Regulation, the samples shall be subjected to photometric measurements for the minimum values at the points indicated P1, P2 and P3 as specified in Figure A4-XII in Annex 4 Table 18 and the required chromaticity coordinates.
2.5.changed
The manufacturer is responsible for carrying out a statistical study of the test results and for defining, in agreement with the competent authority, criteria governing the acceptability of his products in order to meet the requirements laid down for verification of conformity of products in paragraph 3.5.1. of this Regulation. The criteria governing the acceptability shall be such that with a confidence level of 95% the minimum probability of passing a spot check in accordance with Annex 3 (first sampling) would be 0.95. 3 HL and HR: points on HH located at 2.6 degrees to 1 When the left and to driving-beam is reciprocally incorporated with the right passing-beam, HV in the case of the driving-beam shall be the same measuring point HV respectively. as in the case of the passing-beam.
1.2.changed
With respect to photometric performance, the conformity of mass-produced lamps shall not be contested if, when testing the photometric performances of any lamp chosen at random, and equipped with a standard (étalon) light source and/or non-replaceable light source(s) and/or LED light source module(s), as present in the lamp: (a) No measured value deviates from the values prescribed in paragraph paragraph6 of this Regulation; (b) If, in the case of a lamp equipped with a replaceable light source and if results of the test described above do not meet the requirements, tests on lamps shall be repeated using another standard light source.
2.4.1.1.1.deleted
For Classes A and B (driving and/or passing-beam headlamps of Classes A and B (asymmetrical)) to the points Imax, HV1, HL, HR2 in the case of a driving- beam, and to points B 50 L (or R), HV, 50 V, 75 R (or L) and 25 L (or R) in the case of the passing-beam.
2.4.1.1.2.deleted
For Class D (driving and/or passing-beam headlamps of Class D (GDL asymmetrical)) to the points Imax, HV1, HL, HR2 in the case of the driving beam, and to points B 50 L (or R)1, HV, 50 V, 75 R (or L) and 25 L2 (or R2) in the case of the passing beam.
2.4.1.2.deleted
For driving-beam headlamps according to paragraph 5.1. and / or passing- beam headlamps (symmetrical) according to paragraph 5.4. of this Regulation apply:
3.1.changed
The conformity of mass-produced lamps is shall not be contested if the deviation of any specimen of samples C and D (all four lamps) is not more than 20 per cent. Annex 3 In the case that the deviation of both lamps of sample C is not more than 0 per cent the measurement can be closed.
2.4.1.4.deleted
8 and 9, and the lines 1, 5, 6, 8 and 9 as specified in Table 37.
6.changed
With respect to the verification of the change in vertical position of the cut-off line for passing beam passing-beam under the influence of heat, the following procedure shall be applied: One of the lamps or system of sample A shall be tested according to the procedure described in paragraph 3. of Annex 7 after being subjected three consecutive times to the cycle described in paragraph 3.2.2. of Annex 7. The passing beam passing-beam or the system shall be considered as acceptable if r does not exceed 1.5 mrad upwards and does not exceed 2.5 mrad downwards. If this value exceeds 1.5 mrad but is not more than 2.0 mrad upwards or exceeds 2.5 mrad but is not more than 3.0 mrad downwards, a second system of sample A shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 1.5 m rad upwards and shall not exceed 2.5 mrad downwards. However, if this value of 1.5 mrad upwards and 2.5 mrad downwards on sample A is not complied with, another two systems of sample B shall be subjected to the same procedure and the value of r for each of them shall not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards. In the case of front fog lamps in accordance with paragraph 5.5. to this Regulation the lamp shall be considered as acceptable if r does not exceed 3.0 mrad. If this value exceeds 3.0 mrad but is not more than 4.0 mrad, the second front fog lamp of sample A shall be subjected to the test after which the mean of the absolute values recorded in both samples shall not exceed 3.0 mrad. However, if this value of 3.0 mrad on sample A is not complied with, the two front fog lamps of sample B shall be subjected to the same procedure and the value of r for each of them shall not exceed 3.0 mrad. Annex 4
1.2.deleted
of Annex 2; (b) If, in the case of a lamp equipped with a replaceable light source and if results of the test described above do not meet the requirements, tests on lamps shall be repeated using another standard light source.
Annex 4changed
locations Figure A4-I Spherical coordinate measuring system UN projection screen at 25 meter distance E25m= l(h,v)x cos γ/r2
1.4.deleted
The chromaticity coordinates shall be complied with.
1.1.changed
The RID device or part(s) thereof shall be mounted on a goniometer with a fixed horizontal axis and moveable axis perpendicular to the fixed horizontal axis.
1.1.1.changed
The luminous intensity values shall be determined by means of a photoreceptor contained within a square of 65 mm side and, except for cornering lamps, set up to a distance of at least 25 m forward of the centre of reference of each headlamp or lighting unit perpendicular to the measurement axis from the origin of the goniometer. The point HV is the centre-point of the coordinate system with a vertical polar axis. Line h is the horizontal through HV (see Figure A4-1). A4-I).
1.1.2.changed
The angular co-ordinates are specified in deg on a sphere with a vertical polar axis according to the gonio-photometer as defined in Figure A4-1. A4-I.
1.4.changed
The RID Before starting the measurements, the device or part(s) thereof shall be so aimed before starting the measurements that the position of the "cut-off" complies with the relevant requirements for the specific function as described in paragraph 5 to this Regulation. Annex 5.
1.5.changed
In Upon request of the applicant, in case of AFS: a matched pair of lamps the photometric requirements for each single measuring point, segment or zone (angular position) apply to half of the sum of the respective measured values from both lamps together.
1.5.1.changed
Any offset However, in the cases described in paragraph 5.1.4.2. of this Regulation and the centre footnotes of reference Tables 5, 6, 14, 15, 16, 17 and 19 where a provision is specified for one side only, the division by the factor of each lighting unit, with respect to the goniometer rotation axes, should be avoided. This applies especially to the vertical direction and to lighting units producing a "cut-off". 2 does not apply.
1.6.added
In case of AFS (paragraph 5.3.):
1.6.1.changed
When photometric measurements are taken, stray reflections shall Any offset of the centre of reference of each lighting unit, with respect to the goniometer rotation axes, should be avoided by appropriate masking. avoided. This applies especially to the vertical direction and to lighting units producing a "cut-off".
1.6.2.changed
In The photometric requirements for each single measuring point or segment (angular position) of a lighting function or mode as specified in this Regulation apply to half of the event that sum of the results respective measured values from each lamp, from all lighting units of measurements are challenged, measurements shall be taken in such a way as to meet the following requirements: system applied for this function or mode;
1.6.2.1.changed
The distance However, in those cases where a provision is specified for one side only, the division by the factor of measurement shall be such that the law 2 does not apply. These cases are: paragraphs 5.3.2.5.2., 5.3.2.8.1., 5.1.4.2., 5.3.3.4., 5.3.5.1. of the inverse this Regulation, and notes 1 and 7 of the square of the distance is applicable; Table 7.
1.6.3.added
The lighting units of the system shall be measured individually; however, simultaneous measurements may be performed on two or more lighting units of an installation unit, being equipped with the same light source types with respect to their power supply (either power controlled or not), if they are sized and situated such, that their illuminating surfaces are completely contained in a rectangle of not more than 300 mm in horizontal extend and not more than 150 mm vertical extend, and, if a common centre of reference is specified by the manufacturer.
1.6.4.added
The system shall prior to the subsequent test procedures be set to the neutral state.
1.6.5.added
The system or part(s) thereof shall be so aimed before starting the measurements that the position of the "cut–off" complies with the requirements indicated in Table 8. Parts of a system measured individually and having no "cut-off" shall be installed on the goniometer under the conditions (mounting position) specified by the applicant.
1.7.1.added
In the event that the results of measurements are challenged, measurements shall be taken in such a way as to meet the following requirements:
1.7.1.1.added
The distance of measurement shall be such that the law of the inverse of the square of the distance is applicable;
1.7.1.2.added
The measuring equipment shall be such that the angle subtended by the receiver from the reference centre of the light is between 10′ and 1°;
2.changed
Test point locations: Figure A4-II Driving beam test points h-h = The Figures provided in this Annex are intended for information only. The requirements for the coordinates are indicated in paragraph 5. of this Regulation. H-H is the horizontal plane, v-v = plane while V-V is the vertical plane passing through the optical axis of the headlamp Figure A4-III Primary driving beam - position headlamp. For the purpose of test points Figure A4-IV Secondary driving beam - position of test points Figure A4-V Passing-beam the Figures in this Annex, angular positions are indicated for right-hand traffic The test point locations for left-hand traffic are mirrored about traffic. For asymmetric passing-beams the VV line Annex 4 Figure A4-VI Passing beam with gas discharge light sources for right-hand traffic h-h = horizontal plane, v-v = vertical plane passing through the optical axis of the headlamp The test point locations for left-hand traffic are mirrored about the V-V line Figure A4-VII A4-II Driving-beam test points Figure A4-III Driving-beam Class BS - position of test points Figure A4-IV Secondary driving-beam Class CS and DS - position of test points Figure A4-V Classes C and V Passing-beams for right-hand traffic Figure A4-VI AFS Passing-beam for right-hand traffic* * Note: The measurement procedure is prescribed in Annex 4 For the purpose of this Annex: "above it" means vertically above, only; "below it" means vertically below, only. Angular positions of passing-beam photometric requirements are indicated for right-hand traffic and are expressed in deg up (U) or down (D) from H-H respectively right (R) or left (L) from V-V. The test point locations for left-hand traffic are mirrored about the V-V line Annex 4 Figure A4-VIII Passing beam A4-VII Passing-beam test points and zones for Class AS headlamp(s) H-H: horizontal plane passing through V-V: vertical plane focus of headlamp Figure A4-IX Passing beam A4-VIII Passing-beam test points and zones for Class BS headlamp(s) H-H: horizontal plane passing through V-V: vertical plane focus of headlamp Annex 4 Figure A4-X Passing beam A4-IX Passing-beam - position of test points and zones for Classes CS, CS and DS and ES headlamp(s) Figure A4-XI A4-X Light distribution of the Class F3 front fog lamp Annex 4 Figure A4-XII Measuring points for cornering lamps (left side lamp) Figure A4-XIII A4-XI Light distribution of the cornering lamp (Left side lamp) Figure A4-XII Horizontal geometric visibility for cornering lamps values in [°] Figure A4-XIV A4-XIII Vertical geometric visibility for cornering lamps values in [°] Annex 5
Annex 5changed
Visual aiming method of Road Illumination Devices. Definition of "cut-off" line for asymmetric passing-beams passing-beam headlamps and front fog lamps.
1.1.changed
The aiming of a road illumination device enables the luminous intensity distribution of a principal passing-beam headlamp or of at least one lighting unit for a class C passing beam of an AFS in its neutral state shall incorporate a "cut-off" (see Figure A5-I), which enables the headlamp lamp to be adjusted correctly for the photometric measurements and for the aiming on the vehicle. The "cut-off" shall provide: (a) For right hand traffic beams: (i) A straight "horizontal part" towards the left; (ii) A raised "elbow - shoulder" part towards the right. (b) For left hand traffic beams: (i) A straight "horizontal part" towards the right; (ii) A raised "elbow - shoulder" part towards the left. In each case the "elbow-shoulder" part shall have a sharp edge.
1.2.changed
Figure A5-I) as follows. The aiming shall be carried out using a flat vertical screen set up at a distance of 10 m or 25 m (as indicated in item 9 of Annex 1) forward of the headlamp or AFS device and at right angles to the H-V axis as shown in Annex 4. The screen shall be sufficiently wide to allow examination and adjustment of the "cut-off" of the passing-beam device over at least 5° on either side of the V-V line.
1.5.2.deleted
The photometric requirements for each single measuring point (angular position) of a lighting function or mode as specified in this Regulation apply to half of the sum of the respective measured values from all lighting units of the system applied for this function or mode, or, from all lighting units as indicated in the respective requirement;
1.5.2.1.deleted
However in those cases where a provision is specified for one side only, the division by the factor of 2 does not apply. These cases are: paragraphs 5.3.2.5.2., 5.3.2.8.1., 5.1.3.5., 5.1.3.6., 5.3.3.4.1., 5.3.5.1. of this Regulation, and note 4 of Table 9.
2.1.changed
In the case where paragraph 1.2.4. applies, the quality The luminous intensity distribution of the "cut-off" line a principal passing-beam headlamp or of at least one lighting unit for a class C passing-beam of an AFS or of a front fog lamp in its neutral state shall be tested according to the requirements set out in paragraph 2.2. and the instrumental vertical and horizontal adjustment of the beam shall be performed according to the requirements set out in paragraph 2.3. Before carrying out the measurement of the quality of "cut-off", and the instrumental aiming procedure, incorporate a visual pre-aim in accordance with paragraphs 1.2.1. and 1.2.2. is required. "cut-off”.
1.5.3.deleted
The lighting units of the system shall be measured individually; however, simultaneous measurements may be performed on two or more lighting units of an installation unit, being equipped with the same light source types with respect to their power supply (either power controlled or not), if they are sized and situated such, that their illuminating surfaces are completely contained in a rectangle of not more than 300 mm in horizontal extend and not more than 150 mm vertical extend, and, if a common centre of reference is specified by the manufacturer.
2.1.1.added
The asymmetric "cut-off" line shall provide: (a) For right hand traffic beams (see Figure A5-I): (i) A straight "horizontal part" towards the left; (ii) A raised "elbow - shoulder" part towards the right. (b) For left hand traffic beams: (i) A straight "horizontal part" towards the right; (ii) A raised "elbow - shoulder" part towards the left. In each case the "elbow-shoulder" part shall have a sharp edge. Figure A5-I Visual aiming of the asymmetric cut-off line (right hand traffic passing- beam) Note: The scales are different for vertical and horizontal lines.
1.5.4.deleted
The system shall prior to the subsequent test procedures be set to the neutral state.
2.1.2.added
The symmetric "cut-off" line shall provide a straight "horizontal part" towards the left and the right (see Figure A5-II) Figure A5-II Visual aiming of the symmetric cut-off line Note: The scales are different for vertical and horizontal lines.
1.5.5.deleted
The system or part(s) thereof shall be so aimed before starting the measurements that the position of the "cut–off" complies with the requirements indicated in the Table 10. Parts of a system measured individually and having no "cut-off" shall be installed on the goniometer under the conditions (mounting position) specified by the applicant.
3.1.added
Aiming of device designed to provide a driving-beam of the Class A, B, RA, BS, CS or DS (symbols “R”, "HR", “RA”, "XR”, "R-BS”, “WR-CS” or “WR- DS”)
3.1.1.added
In the case of a road illumination device designed to provide a driving-beam not being adjustable independently from the passing-beam, measurements of the luminous intensity of the driving-beam shall be taken with the same alignment as for the measurements of the passing-beam. The passing-beam shall be aimed according to paragraph 3.2.
3.1.2.added
In the case of a road illumination device providing a driving-beam being adjustable independently from the passing-beam, it shall be so adjusted that the area of maximum luminous intensity is centered on the point of intersection of lines H-H and V-V
3.2.added
Aiming of device designed to provide a passing-beam (asymmetric “cut-off” line) of the Classes C and V
1.6.2.2.deleted
The measuring equipment shall be such that the angle subtended by the receiver from the reference centre of the light is between 10′ and 1°;
3.2.1.added
In the case of a road illumination device providing a principal passing-beam headlamp or at least one lighting unit for a class C passing-beam of an AFS, the device shall be visually aimed by means of the "cut-off" (see Figure A5-I) as follows.
1.6.2.3.deleted
The intensity requirement for a particular direction of observation shall be satisfied if the required intensity is obtained in a direction deviating by not more than one quarter of a degree from the direction of observation. Annex 4
3.2.1.1.added
For vertical adjustment: the horizontal part of the "cut-off" is moved upward from below line B and adjusted to its nominal position one per cent (0.57°) below the H-H line;
3.2.1.2.added
For horizontal adjustment: the "elbow – shoulder" part of the "cut-off" shall be moved from: - right to left for right hand traffic; or - left to right for left hand traffic and shall be horizontally positioned after its movement so that: (a) Above the line 0.2°D its "shoulder" shall not exceed the line A: - to the left for right hand traffic; or - to the right for left hand traffic (b) The line 0.2°D or below its "shoulder" should cross the line A; and (c) The kink of the "elbow" is basically located within +/-0.5° to the left or right of the V-V line;
3.2.2.added
In the case of a headlamp designed to provide bend lighting its alignment may be changed, provided that the axis of the beam is not displaced vertically by more than 0.2°.
3.3.added
Aiming of device designed to provide a passing-beam (symmetric “cut-off” line) of the Classes AS, BS, CS and DS (see Figure A5-II)
3.3.1.added
In the case of a road illumination device providing a principal passing-beam headlamp, the device shall be visually aimed by means of the "cut-off" (see Figure A5-II) as follows.
3.3.1.1.added
For vertical adjustment: according to paragraph 3.2.1.1.
1.2.1.deleted
For vertical adjustment: the horizontal part of the "cut-off" is moved upward from below line B and adjusted to its nominal position one per cent (0.57 degrees) below the H-H line; Figure A5-I Visual aiming of the cut-off Note: The scales are different for vertical and horizontal lines.
3.3.1.2.added
For horizontal adjustment: the cut-off line shall be so positioned that the projected beam pattern appears approximately symmetrical to the V-V line.
1.2.2.deleted
For horizontal adjustment: the "elbow – shoulder" part of the "cut-off" shall be moved: For right hand traffic from right to left and shall be horizontally positioned after its movement so that: (a) Above the line 0.2° D its "shoulder" shall not exceed the line A to the left; (b) The line 0.2° D or below its "shoulder" should cross the line A; and (c) The kink of the "elbow" is basically located within +/-0.5 degrees to the left or right of the V-V line; or For left hand traffic from left to right and shall be horizontally positioned after its movement so that: (a) Above the line 0.2° D its "shoulder" shall not exceed the line A to the right; (b) On the line 0.2° or below its "shoulder" cross the line A; and (c) The kink of the "elbow" should be primarily on the V-V line;
3.4.added
Aiming of device designed to provide a front fog lamp (symmetric “cut-off” line) of Class F3 (see Figure A5-II).
1.2.3.deleted
Where a headlamp or AFS so aimed does not meet the requirements set out in paragraphs this Regulation 5.2. to 5.4. of this Regulation respectively, its alignment may be changed, provided that the axis of the beam is not displaced: Horizontally from line A by more than: (a) 0.5° to the left or 0.75° to the right, for right hand traffic; or (b) 0.5° to the right or 0.75° to the left, for left hand traffic; and Annex 5 Vertically not more than 0.25° up or down from line B.
3.4.1.added
In the case of a road illumination device providing a front fog lamp, the device shall be visually aimed by means of the "cut-off" (see Figure A5-II) as follows.
1.2.4.deleted
If, however, vertical adjustment cannot be performed repeatedly to the required position within the tolerances described in paragraph 1.2.3., the instrumental method of paragraph 2. shall be applied to test compliance with the required minimum quality of the "cut-off" and to perform the vertical and horizontal adjustment of the beam.
3.4.1.1.added
For vertical adjustment: the "cut-off" is moved upward from below line B and adjusted to its nominal position 1 degrees below the H-H line;
1.2.5.deleted
When so aimed, a headlamp, if its approval is sought solely for provision of a passing-beam9, need comply only with the requirements set out in paragraphs
3.4.1.2.added
For horizontal adjustment: according to paragraph 3.3.1.2. When the front fog lamp is designed for use in pairs or has otherwise an asymmetric beam pattern, it shall be horizontally aligned according to the specification of the applicant, or otherwise in such a way that the cut-off line appears symmetrical to the V-V line.
5.2.deleted
to 5.4. of this Regulation; if it is intended to provide both a passing-beam and a driving-beam, it shall comply with the requirements set out in paragraphs
5.1.deleted
to 5.4. of this Regulation.
3.5.1.added
In the case of a road illumination device providing a cornering lamp the device shall be installed on the goniometer in the axis of reference according to requirements set out in paragraph 3.1.2.1. (a) and (b) of this Regulation.
4.1.added
Where a road illumination device aimed as described in paragraph 3. does not meet the device specific requirements set out in paragraphs 5. or 6.2. of this Regulation, its alignment may be changed, provided that the axis of the beam is not displaced: Horizontally not more than: (a) 0.75° to the left or to the right for device designed to provide a passing-beam or a driving-beam not being adjustable independently from the passing-beam; or (b) 1° to the left or to the right for device designed to provide a driving- beam being adjustable independently from the passing-beam; or (c) 2° to the left or to the right for device designed to provide a front fog lamp or a cornering lamp Vertically not more than: (a) 0.25° up or down for device designed to provide a passing-beam or a driving-beam not being adjustable independently from the passing-beam; or (b) 0.5° up or down for device designed to provide a driving-beam being adjustable independently from the passing-beam; or (c) 0.5° up or down for device designed to provide a front fog lamp or a cornering lamp
2.2.deleted
To determine the minimum sharpness, measurements shall be performed by vertically scanning through the horizontal part of the "cut-off" in angular steps of 0.05° at either a measurement distance of: (a) 10 m with a detector having a diameter of approximately 10 mm; or (b) 25 m with a detector having a diameter of approximately 30 mm. The measuring distance at which the test was carried out shall be recorded in item 9. of the communication form (see Annex 1 to this Regulation). To determine the maximum sharpness, measurements shall be performed by vertically scanning through the horizontal part of the "cut-off" in angular steps of 0.05° exclusively at a measurement distance of 25 m and with a detector having a diameter of approximately 30 mm. The "cut-off" quality shall be considered acceptable if the requirements of paragraphs 2.2.1. to 2.2.3. comply with at least one set of measurements.
4.1.1.added
Where a driving-beam not being adjustable independently from the passing- beam aimed as described in paragraph 3 does not meet the specific requirements set out in paragraph 5.1. or 6.2. of this Regulation the alignment of the device may be changed with respect to the passing-beam first aiming.
4.1.2.added
Where an AFS aimed as described in paragraph 3. does not meet the specific requirements set out in paragraph 5.3. or 6.2. of this Regulation the alignment of the system may be changed in each class independently with respect to the first aiming.
2.2.2.deleted
The sharpness factor G is determined by scanning vertically through the horizontal part of the "cut-off" at 2.5° from the V-V where: G = (log Eβ - log E(β + 0.1°)) where β = the vertical position in degrees and E = the illumination on the aiming screen. 1 This paragraph should be amended when an objective test method is available. The value of G shall not be less than 0.13 (minimum sharpness) and not greater than 0.40 (maximum sharpness).
4.2.added
If, however, vertical adjustment of the device providing a passing-beam or a front fog lamp cannot be performed repeatedly to the required position within the tolerances described in paragraph 4.1., the instrumental method of Annex 6 shall be applied to test compliance with the required minimum quality of the "cut-off" and to perform the vertical and horizontal adjustment of the beam.
2.2.3.deleted
The part of the horizontal "cut-off" that serves for vertical adjustment shall be horizontal between 1.5° and 3.5° from the V-V line (see Figure A5-II). The inflection points of the "cut-off" gradient at the vertical lines at 1.5°, 2.5° and 3.5° shall be determined by the equation: The maximum vertical distance between the inflection points determined shall not exceed 0.2°. (d2 (log E) / dβ2 = 0).
Annex 6changed
Definition and sharpness of the horizontal "cut-off" line and Instrumental aiming procedure by means of this "cut-off" line method for symmetrical passing beam headlamps and a device providing a passing-beam or a front fog lamps lamp and requirements for "cut- off" line
1.1.changed
The aiming of a road illumination device enables the luminous intensity distribution of the symmetrical passing-beam headlamps and front fog lamp shall incorporate a "cut-off" line which enables the lamp to be adjusted correctly for the photometric measurements and for the aiming on the vehicle. The characteristics of the "cut-off" line shall comply with the requirements set out in paragraphs 2. to 4.:
1.2.added
The instrumental aiming method shall be applied to test compliance with the required minimum quality of the "cut-off" and to perform the vertical and horizontal adjustment of the beam only if the vertical adjustment of the device providing a passing-beam or a front fog lamp cannot be performed repeatedly to the required position and tolerances described in Annex 5.
1.3.added
The “cut-off” definition is given in Annex 5, paragraph 2.
2.1.changed
For visual adjustment In the case where paragraph 1.2. applies, the quality of the lamp the "cut-off" line shall provide: be tested according to the requirements set out in paragraph 2.2. and the instrumental vertical and horizontal adjustment of the beam shall be performed according to the requirements set out in paragraph 2.3. Before carrying out the measurement of the quality of "cut-off", and the instrumental aiming procedure, a visual pre-aim in accordance with device specific paragraph(s) of Annex 5 is required.
2.2.added
To determine the minimum sharpness, measurements shall be performed by vertically scanning through the horizontal part of the "cut-off" in angular steps of 0.05° at either a measurement distance of: (a) 10 m with a detector having a diameter of approximately 10 mm; or (b) 25 m with a detector having a diameter of approximately 30 mm. The measuring distance at which the test was carried out shall be recorded in item 9. of the communication form (see Annex 1 to this Regulation). To determine the maximum sharpness, measurements shall be performed by vertically scanning through the horizontal part of the "cut-off" in angular steps of 0.05° exclusively at a measurement distance of 25 m and with a detector having a diameter of approximately 30 mm. The "cut-off" quality shall be considered acceptable if the requirements of paragraphs 2.2.1. to 2.2.3. comply with at least one set of measurements.
2.2.2.added
The sharpness factor G is determined by scanning vertically through the horizontal part of the "cut-off" at: (a) 2.5° from the V-V line for passing-beam designed to provide asymmetric “cut-off” line; or 1 This paragraph should be amended when an objective test method is available. (b) 2.5° left and right from the V-V line for passing-beam and front fog lamp designed to provide symmetric “cut-off” line where: G = (log Eβ - log E(β + 0.1°)) where β = the vertical position in degrees and E = the illumination on the aiming screen. The value of G shall not be less than: (a) 0.13 (minimum sharpness) for passing-beam designed to provide asymmetric “cut-off” line; or (b) 0.08 (minimum sharpness) for passing-beam and front fog lamp designed to provide symmetric “cut-off” line and not greater than 0.40 (maximum sharpness) for passing-beam designed to provide asymmetric “cut-off” line.
2.2.3.1.added
Inflection points of the "cut-off" gradient (a) For passing-beam designed to provide asymmetric “cut-off” line the part of the horizontal "cut-off" that serves for vertical adjustment shall be horizontal between 1.5° and 3.5° from the V-V line (see Figure A6- I). (b) For passing-beam and front fog lamp designed to provide symmetric “cut-off” line the part of the horizontal "cut-off" shall be horizontal between 3° left and right from the V-V line (see Figure A6-II). The inflection points of the "cut-off" gradient at the vertical lines at 1.5°, 2.5° and 3.5° shall be determined by the equation: (d2 (log E) / dβ2 = 0). The maximum vertical distance between the inflection points determined shall not exceed: (a) 0.2° for passing-beam designed to provide asymmetric “cut-off” line; or (b) 0.5° for passing-beam and front fog lamp designed to provide symmetric “cut-off” line Figure A6-I Measurement of the asymmetric "cut-off" quality Note: The scales are different for vertical and horizontal lines. Figure A6-II Measurement of the symmetric "cut-off" quality and instrumental vertical adjustment Note: The scales are different for vertical and horizontal lines.
2.3.added
If the "cut-off" complies with the quality requirements of paragraph 2.2. the beam adjustment may be performed instrumentally.
2.3.1.added
Moving upward from below the line B, a vertical scan is carried out through the horizontal part of the "cut-off": (a) at 2.5° from V-V line for passing-beam headlamp designed to provide asymmetric “cut-off” line (see Figure A6-III) on the left side of V-V line for right hand traffic and on the right side of V-V line for left hand traffic (b) on the V-V line for passing-beam and front fog lamp designed to provide symmetric “cut-off” line (see Figure A6-II) The inflection point (where d2 (log E) / dβ2 = 0) is determined and positioned on the line B situated: (a) 0.57° (1 per cent) below H-H line for passing-beam headlamp (b) 1° below H-H line for front fog lamp
2.3.2.1.added
Horizontal adjustment of passing-beam headlamp designed to provide asymmetric “cut-off” line The applicant shall specify one of the following horizontal aim methods: (a) The "0.2°D line" method (see Figure A6-III). A single horizontal line at 0.2°D shall be scanned from 5° left to 5° right after the lamp has been aimed vertically. The maximum gradient "G" determined using the formula G = (log Eβ - log E(β + 0.1°)) where β is the horizontal position in degrees, shall not be less than 0.08. The inflection point found on the 0.2°D line shall be positioned on the line A. Figure A6-III Instrumental vertical and horizontal adjustment for asymmetric “cut-off” line- horizontal line scan method Note: The scales are different for vertical and horizontal lines. (b) The "3 line" method (see Figure A5-IV) Three vertical lines shall be scanned from 2°D to 2°U at 1°R, 2°R, and 3°R after the lamp has been aimed vertically. The respective maximum gradients "G" determined using the formula: G = (log Eβ – log E(β + 0.1°)) where β is the vertical position in degrees, shall not be less than 0.08. The inflection points found on the three lines shall be used to derive a straight line. The intersection of this line and the line B found while performing vertical aim shall be placed on the V line. Figure A6-IV Instrumental vertical and horizontal adjustment for asymmetric “cut-off” line - Three-line scan method Note: The scales are different for vertical and horizontal lines.
2.3.2.2.added
Horizontal adjustment of passing-beam headlamp or front fog lamp designed to provide symmetric “cut-off” line: The cut-off line shall be so positioned that the projected beam pattern appears approximately symmetrical to the V-V line.
2.3.2.2.1.added
In case of front fog lamps designed for use in pairs or has otherwise an asymmetric beam pattern, the “cut-off” line shall be horizontally aligned according to the specification of the applicant, or otherwise in such a way that the cut-off line appears symmetrical to the V-V line.
1.changed
Once the photometric values have been measured according to this Regulation: (a) In the case of a headlamp with an asymmetrical passing-beam pattern: at the point for or AFS: Imax for driving-beam and in points 25L, 50 R, B 50 L 40L, 50R, B50L for passing-beam (or 25R, 50 L, B 50 R 40R, 50L, B50R for headlamps designed for left-hand traffic); (b) In the case of a headlamp with a symmetrical beam pattern: at the point for passing-beam: Imax for driving beam driving-beam and in points 0.50U/1.5L 0.50°U/1.5°L and 0.50U/1.5R, 0.50°U/1.5°R, 50R, 50L for Class B passing beam BS passing-beam and in points 0.86D- 3.5R, 0.86D-3.5L, 0.50U-1.5L and 0.50U-1.5R 0.86°D-3.5°R, 0.86°D-3.5°L, for Classes C, D CS and E, for passing beam; DS passing-beams; (c) In the case of a front fog lamps: at the point of maximum illumination in zone D (I max) and in the point HV; (d) In the case of an AFS: at the point for Imax for driving-beam and in points 25L, 50V, B 50 L (or R), whichever applies for passing-beam; A complete sample shall be tested for stability of photometric performance in operation.
1.1.changed
In the case of headlamps or front fog lamps: "Complete sample" shall be understood to mean the complete lamp itself including ballast(s) and those surrounding body parts, light sources or LED light source module(s) which could influence its thermal dissipation.
1.2.changed
In the case of an AFS: (a) "Complete sample" shall be understood to mean the complete right and left side of a system itself including electronic light source control- gear(s) and/or supply and operating device(s) and those surrounding body parts and lamps which could influence its thermal dissipation. Each installation unit of the system and lamp(s) and/or LED light source module, if any, of the complete system may be tested separately. (b) "Test sample" in the following text means correspondingly either the "complete sample" or the installation unit under test. (c) The expression "light source" shall be understood to comprise also any single filament of a filament light source, LED light source, LED modules or light emitting parts of a LED light source or LED module Annex 7
2.1.1.1.changed
The device shall be operated for a period according to the specified time, so that: (a) In the case where a device is designed to provide only one lighting function (driving beam (driving-beam or passing beam passing-beam or front fog lamp) and not more than one class in case of passing beam, passing-beam, the corresponding light source(s) emitting element (s) is/are lit for the time,2 time2 specified in paragraph 2.1.; (b) In the case where a device is designed to provide a passing-beam and one two or more driving-beams or in lighting functions, the case of a headlamp with a passing- beam and a front fog lamp: (i) The device shall be subjected to the following cycle until the time specified is reached as follows: - 15 minutes, principal passing-beam main mode lit - 5 minutes, all other functions which, according to the manufacturer's specifications, in the same body are intended to be used simultaneously2 and which, in combination draw the highest total wattage lit 1 For the test schedule see Annex 7, Appendix 1. 2 When the tested headlamp includes signaling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. (c) In the case of a direction indicator lamp, it passing-beam designed to provide bend lighting with the addition of light source(s) or light source module(s), it/they shall be lit in flashing mode with an on/ off time switched ON for one minute, and switched OFF for nine minutes during the activation of approximately one to one. (ii) the passing-beam only. If the applicant declares that the headlamp is has several additional light sources used to be used with only the passing-beam lit or only the driving-beam(s) lit3 at a time, produce bend lighting, the test shall be carried out in accordance with this condition, activating1 successively the passing-beam half combination of light source(s) that represents the time and the driving-beam(s) (simultaneously) for half the time specified in paragraph 2.1. (iii) most severe operating condition. (d) In the case of a passing beam headlamp equipped with cornering lamp with the addition of light source(s) or light source module(s), it /they shall be switched ON for one minute, and a driving beam provided by switched OFF for nine minutes during the same gas-discharge activation of the passing-beam only. (e) In the case that the driving-beam uses several light source, the cycle will be: - 15 minutes, passing beam lit - 5 minutes, all driving beam contributors lit. (c) In case of an AFS, (i) Where a test sample provides more than one function or class of passing beam according to this Regulation: sources and if the applicant declares that each specified function or class of passing beam a part of the test sample has its own driving-beam (one of these additional light source(s), being sources) will be used exclusively lit2 at a time, for short time signals (flash to pass), the test shall be carried out in accordance with without this condition, activating1 the most power consuming mode of each specified function or class of passing beam successively for the same (equally divided) part of the time specified in paragraph driving-beam.
2.1.1.2.changed
The voltage shall be applied to the terminals of the test sample as follows: (a) In case of replaceable filament light source(s) operated directly under vehicle voltage system conditions: The test shall be performed at 6.3 V, 13.2 V or 28.0 V as applicable except if the applicant specifies that the test sample may be used at a 1 For the test schedule see Annex 7, Appendix 1. 2 When the tested headlamp includes signaling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing mode with an on/ off time of approximately one to one. different voltage. In this case, the test shall be carried out with the filament light source operated at the highest voltage that can be used. (b) In case of replaceable gas discharge light source(s): The test voltage for the electronic light source control-gear or the light source In source, in case the ballast is integrated with the light source source, is 13.2 ± 0.1 ±0.1 volts for 12 V vehicle voltage system, or otherwise specified in the application for approval. (c) In the case of non-replaceable light source operated directly under vehicle voltage system conditions: All measurements on lighting units equipped with non-replaceable light sources (filament light sources and/ or others) shall be made at 6.3 V, 13.2 V or 28.0 V or at other voltages according to the vehicle voltage system as specified by the applicant respectively. (d) In the case of light sources, replaceable or non-replaceable, being operated independently from vehicle supply voltage and fully controlled by the system, or, in the case of light sources supplied by a supply and operating device, the test voltages as specified above shall be applied to the input terminals of that device. The test laboratory may require from the manufacturer the supply and operating device or a special power supply needed to supply the light source(s). (e) LED light source(s) and LED light source module(s) shall be measured at 6.75 6.3 V, 13.2 V or 28.0 V respectively, if not otherwise specified within the pertinent Regulation. LED light source(s) and LED light source module(s) operated by an electronic light source control gear, shall be measured as specified by the applicant. (f) Where signalling lamps are grouped, combined or reciprocally incorporated into the test sample and operating at voltages other than the nominal rated voltages of 6 V, 12 V or 24 V respectively, the voltage shall be adjusted as declared by the manufacturer for the correct photometric functioning of that lamp. (g) For a gas-discharge light source, the test voltage for the ballast or for the light source in case the ballast is integrated with the light source is 13.2 ± 0.1 volts for 12 V network system, or otherwise specified in the application for approval.
2.1.2.1.changed
Annex 7 Once the headlamp has been stabilized to the ambient temperature, the headlamp lens and the external lens, if any, shall be cleaned with a clean, damp cotton cloth. It shall then be inspected visually; no distortion, deformation, cracking or change in colour of either the headlamp lens or the external lens, if any, shall be noticeable.
2.1.2.2.added
To comply with the requirements, the photometric values shall be verified in the following points:
2.1.2.2.1.changed
In the case of a headlamp with an asymmetrical beam passing-beam pattern: (a) Passing-beam, except for AFS system: Passing-beam: - 50 R 50R - B 50 L – 25L B50L - 40L for headlamps designed for right-hand traffic; - 50 L 50L - B 50 R – 25R B50R - 40R for headlamps designed for left-hand traffic. (b) Passing-beam, for AFS system: Class C passing beam and each specified other passing beam class: 50V, B50L, and 25RR, if applicable (c) Driving-beam: Point Imax Another aiming may be carried out to allow for any deformation of the headlamp base due to heat (the change of the position of the cut-off line is covered in paragraph 3. of this Annex). 3.). Except for point B 50 L, B50L, a 10 per cent discrepancy between the photometric characteristics and the values measured prior to the test is permissible including the tolerances of the photometric procedure. The value measured at point B 50 L B50L shall not exceed the photometric value measured prior to the test by more than 170 1.70∙102 cd.
2.1.2.2.2.changed
To comply In the case of a headlamp with a symmetrical passing-beam pattern: (a) Class BS headlamp: - Passing-beam: 50R - 50L - 0.50°U/1.5°L and 0.50°U/1.5°R. - Driving-beam: Imax (b) For Classes CS and DS headlamp: - Passing-beam: 0.86°D/3.5°R - 0.86°D/3.5°L - 0.50°U/1.5°L and 0.50°U/1.5°R. - Driving-beam: Imax Another aiming may be carried out to allow for any deformation of the requirements, headlamp base due to heat (the change of the position of the cut-off line is covered in paragraph 3.). Except for points 0.50°U/1.5°L and 0.50°U/1.5°R, a 10 per cent discrepancy between the photometric characteristics and the values measured prior to the test is permissible including the tolerances of the photometric procedure. The value measured at points 0.50°U/1.5°L and 0.50°U/1.5°R shall be verified in not exceed the following points: photometric value measured prior to the test by more than 2.55∙102 cd.
2.1.2.2.3.changed
In the case of front fog lamps on line 5 at point h = 0 HV and the point of Imax in zone D. Another aiming may be carried out to allow for any deformation of the front fog lamp base due to heat (the change of the position of the cut-off line is covered in paragraph 3. of this Annex). 3.). A 10 per cent discrepancy between the photometric characteristics and the values measured prior to the test is permissible including the tolerances of the photometric procedure.
2.2.changed
After being tested as specified in paragraph 2.1., the headlamp shall be operated for one hour as described in paragraph 2.1.1. for each function or class of passing beam5 after being prepared as prescribed in paragraph 2.2.1., and checked as prescribed in paragraph 2.1.2., after each test a sufficient cooling down period must be assured.
2.2.1.2.changed
The test mixture shall be uniformly applied to the entire light-emitting surface of the headlamp and then left to dry. This procedure shall be repeated until the illumination value has dropped to 15-20 per cent of the values measured for each following point under the conditions described below: (a) In the case of a headlamp with an asymmetrical beam pattern: pattern or AFS: (i) Point of Imax in passing-beam/driving-beam and in driving-beam only; (ii) 50 R 50R and 50 V 40L for a headlamp producing only a passing-beam, designed for right-hand traffic; (iii) 50 L 50L and 50 V 40R for a headlamp producing only a passing-beam, designed for left-hand traffic; (iv) 50V for a class C passing beam of AFS system, and each specified passing beam mode. traffic. (b) In the case of a headlamp with a symmetrical beam pattern: (i) For Class B BS headlamp: - Passing beam / driving beam Passing-beam/driving-beam and driving beam driving-beam only: Point of Imax - Passing beam Passing-beam only: B 50 50L and 50 V 50R (ii) For Class C, D Classes CS and E DS headlamp: - Passing beam/driving beam Passing-beam/driving-beam and driving beam driving-beam only: Point of Imax 5 The class W passing beam, if any, is disregarded for lighting units providing or contributing to any other passing beam class or lighting function. Annex 7 - Passing beam Passing-beam only: 0.50U/1.5L 0.50°U/1.5°L, 0.50°U/1.5°R and 1.5R and 0.86D/V 0.86°D/V (c) In the case of a front fog lamps: lamp: - point of Imax in zone D.
3.changed
Test for change in vertical position of the cut-off line under the influence of heat heat. This test consists of verifying that the vertical drift of the cut-off line under the influence of heat does not exceed a specified value for an operating headlamp producing a passing-beam, for front fog lamps, or in the case of an AFS for a system or part(s) of emitting a class C (basic) passing-beam, or each specified passing-beam mode. The device tested in accordance with paragraph 2., shall be subjected to the test described in paragraph 3.1., without being removed from or readjusted in relation to its test fixture. If the AFS consists of more than one lighting unit or more than one assembly of lighting units which provide a cut-off, each of these is understood to be a test sample for the purpose of this test and must be tested separately. If the AFS has a moving optical part, only the position closest to the average vertical angular stroke and/or the initial position according to the neutral state is chosen for this test. The test is confined to signal input conditions corresponding to a straight road, only.
3.1.2.changed
In the case of a device with an asymmetrical beam pattern: the position of the "cut-off" line in its horizontal part (between V-V and the vertical lines passing through point B 50 L B50L for right-hand traffic or B 50 R B50R for left-hand traffic) shall be verified 3 minutes (r3) and 60 minutes (r60) respectively after operation.
3.1.3.changed
In the case of a headlamp with a symmetrical beam pattern: the position of the "cut-off" line in its horizontal part (between V-V and the vertical lines passing through point 50 L 50L and 50 R 50R for Class BS headlamp, 3.5 L 3.5°L and 3.5 R 3.5°R for Class CS, CS and DS and ES headlamp) shall be verified 3 minutes (r3) and 60 minutes (r60) respectively after operation.
3.1.4.changed
In the case of a front fog lamps: the position of the "cut-off" line between a point situated 3.0 degrees 3.0° left and a point situated 3.0 degrees 3.0° right of the cut- off cut-off line V-V shall be verified 3 minutes (r3) and 60 minutes (r60) respectively after operation. The measurement of the variation in the cut-off line position as described above shall be carried out by any method giving acceptable accuracy and reproducible results.
3.2.2.changed
However, if the result does not comply with the requirements in paragraph 3.2.1. and does not exceed the values in Table A7-1, a further sample mounted on a test fixture representative of the correct installation on the vehicle shall be tested as described in paragraph 3.1. after being subjected three consecutive times to the cycle as described below, in order to stabilise the position of the mechanical parts of the device: (a) Operation of the device for one hour (the voltage shall be adjusted as specified in paragraph 2.1.1.2.); (b) One hour period with the lamp switched off. OFF. After these three cycles, the device shall be considered as acceptable if the absolute values Δr measured according to paragraph 3.2. on this further sample meet the requirements in paragraph 3.2.1. Table A7-1 Movement values Movement Device Value Headlamp or AFS 1.5 mrad Upward Front fog lamp 3.0 mrad Downward All 3.0 mrad Annex 7 – Appendix 1
Annex 7 - Appendix 1changed
of photometric performance Abbreviations: P: passing-beam lamp D: driving-beam lamp (D1 + D2 means two driving-beams) F: front fog lamp : Means continuously lit means a cycle of 15 minutes off and 5 minutes lit : means a cycle of 15 minutes lit and 5 minutes off means a cycle of 9 minutes off and 1 minute lit All the following grouped headlamps and front fog lamps together with the added marking symbols are given as examples and are not exhaustive. Figure A7-I Example of a headlamp equipped with one lighting function and bend lighting and/or cornering lamp. light source of Main mode (P or D or F) Additional light source(s) or light source module(s) of bend light and /or cornering lamp. (during the activation of the passing-beam only) Figure A7-II Example of a headlamp equipped with several lighting functions, and bend lighting and/or cornering lamp. Light source of Main mode (P or D or F) Light source of all other functions (and if possible main mode) Additional light source(s) or light source module(s) of bend light and /or cornering lamp. (during the activation of the passing-beam only)
2.changed
For devices with outer lens made of plastic material: The mixture of water and polluting agent to be applied to the device shall be composed of: (a) 9 parts by weight of silica sand with a particle size of 0-100 μm; (b) 1 part by weight of vegetal carbon dust produced from beech wood with a particle size of 0-100 μm; (c) 0.2 parts by weight of NaCMC;1 and (d) 5 parts by weight of sodium chloride (pure at 99 per cent); (e) 13 parts by weight of distilled water with a conductivity of  1 mS/m; and (f) 2 ± 1 drops by weight of surfactant.2 The mixture shall not be more than 14 days old. 1 NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall have a degree of substitution (DS) of 0.6-0.7 and a viscosity of 200-300 cP for a 2 per cent solution at 20° C. 2 The tolerance on quantity is due to the necessity of obtaining a dirt that correctly spreads out on all the plastic lens. Annex 8
1.1.changed
A test report shall be prepared on the base of this Annex, covering the test and test results as described below for the tests 3.1 3.1. to 3.5, 3.5., which will be added to the test report and the documentation to a specific device for approval. The road illumination device used for this test shall be noted in the test report.
1.2.1.1.changed
Ten of these lenses may be replaced by ten samples of material at least 60 mm x 80 mm in size, having a flat or convex outer surface and a substantially flat area (radius of curvature not less than 300 mm) in the middle measuring at least 15 mm x 15 mm;
2.2.changed
The two samples of complete road illumination devices supplied pursuant to paragraph 3.1.3.4. 3.1.2.4. of this Regulation and incorporating lenses of plastic material shall, with regard to the lens material, satisfy the requirements indicated in paragraph 3.7.
3.1.1.changed
Three new samples (lenses) shall be subjected to five cycles of temperature and humidity (RH = relative humidity) change in accordance with the following programme: (a) 3 hours at 40 °C ± 2 °C and 85-95 per cent RH; (b) 1 hour at 23 °C ± 5 °C and 60-75 per cent RH; (c) 15 hours at -30 °C ± 2 °C; (d) 1 hour at 23 °C ± 5 °C and 60-75 per cent RH; (e) 3 hours at 80 °C ± 2 °C; (f) 1 hour at 23 °C ± 5°C 5 °C and 60-75 per cent RH; Before this test, the samples shall be kept at 23 °C ± 5 °C and 60-75 per cent RH for at least four hours. Note: The periods of one hour at 23 °C ± 5 °C shall include the periods of transition from one temperature to another which are needed in order to avoid thermal shock effects.
3.1.2.2.changed
These measurements shall be made after photometric stability (as defined in UN Regulation No. 48) using a standard (étalon) light source, or with the light source(s) and/or light source and/or LED module(s), or if applicable with a standard gas-discharge light source, module(s) as present in the road illumination device, at the following points: (a) In the case of AFS, passing-beam of classes A, B C and D: V and of driving- beam of classes A and B: - B 50 L B50L and 50 R 50R for the passing-beam (B 50 R (B50R and 50 L 50L in the case of headlamps intended for left-hand traffic); - Imax for the driving-beam. (b) In the case of AFS: - B50L and 50V for the Class C passing-beam lighting; - Imax for the driving-beam of a system (c) In the case of classes BS, CS, DS CS and ES: DS: - B 50, B50, 50L and 50R for Class BS headlamp, 0.86D/3.5R, 0.86D/3.5L, 0.50U/1.5L 0.86°D/3.5°R, 0.86°D/3.5°L, 0.50°U/1.5°L and 1.5R 0.50°U/1.5°R for Class CS, CS and DS and ES headlamps for the passing beam passing-beam or a passing/driving lamp; - Imax for the driving beam driving-beam of a driving lamp or a passing/driving lamp; (d) (c) In the case of front fog lamps: - intersection VV V-V line with line 6 and Annex 8 - intersection VV V-V line with line 4.
3.2.2.2.changed
Soak a piece of cotton cloth (as per ISO 105) until saturation with the mixture defined in paragraph 3.2.2.1. and, within 10 seconds, apply it for 10 minutes to the outer face of the sample at a pressure of 50 N/cm2, corresponding to an effort of 100 N applied on a test surface of 14 mm x 14 mm. During this 10-minute period, the cloth pad shall be soaked again with the mixture so that the composition of the liquid applied is continuously identical with that of the test mixture prescribed. During the period of application, it is permissible to compensate the pressure applied to the sample in order to prevent it from causing cracks.
3.2.3.1.changed
After the test of resistance to atmospheric agents, the outer face of the samples shall be free from cracks, scratches, chipping and deformation, and the mean T2  T3 𝑇2 − 𝑇3 variation in transmission Δt = , measured on the three samples T2 𝑇2 according to the procedure described in Appendix 2 to this Annex shall not exceed 0.020 (tm (Δtm < 0.020).
3.2.3.2.changed
After the test of resistance to chemical agents, the samples shall not bear any traces of chemical staining likely to cause a variation of flux diffusion, whose T5  T4 𝑇5 − 𝑇4 mean variation Δd = , measured on the three samples according to T2 the 𝑇2 procedure described in Appendix 2 to this Annex shall not exceed 0.020 (dm < 0.020).
3.3.changed
If necessary necessary, the following test shall be done: Flat samples of each light transmitting plastic component of the road illumination device are exposed to the light of the light source(s). The parameters such as angles and distances of these samples shall be the same as in the road illumination device. These samples shall have the same colour and surface treatment, if any, as the parts of the road illumination device. After 1,500 hours of continuous operation, the colorimetric requirements of the transmitted light must be met with a new light source, and the surfaces of the samples shall be free of cracks, scratches, scalings or deformation. The UV-resistance testing of internal materials to light source radiation is not necessary if light sources according to UN Regulation No. 37 and/or low-UV- type gas discharge light sources and/or low-UV-type LED modules are being applied or if provisions are taken, to shield the relevant system components from UV radiation, e.g. by glass filters.
3.4.1.changed
The outer face of three samples (lenses or samples of material) shall be heated to 50 °C ± 5 °C and then immersed for five minutes in a mixture maintained at 23 °C ± 5 °C and composed of 99 parts distilled water containing not more than 0.02 per cent impurities and one part alkylaryl sulphonate. At the end of the test, the samples shall be dried at 50 °C ± 5 °C. The surface of the samples shall be cleaned with a moist cloth. Annex 8
3.4.3.changed
After the above two tests have been performed successively, the mean value 𝑇2 − 𝑇3 of the variation in transmission Δt = T2  T3 , measured on the three samples T2 𝑇2 according to the procedure described in Appendix 2 shall not exceed 0.010 (Δtm < 0.010).
3.5.2.changed
After this test, the variations: T2  T3 𝑇2 − 𝑇3 in transmission: Δt = , T2 T5  T4 𝑇2 𝑇5 − 𝑇4 and in diffusion: Δd = , T2 𝑇2 shall be measured according to the procedure described in Appendix 2 in the area specified in paragraph 1.2.1.1. The mean value of the three samples shall be such that: Δtm < 0.100; Δdm < 0.050.
3.7.1.2.1.added
In the case of AFS, passing-beam of classes C and V and of driving-beam of classes A and B, after the test the results of photometric measurements carried out on the headlamp in accordance with this Regulation shall not exceed: (a) By more than 30 per cent the maximum values prescribed at points B50L and HV and by more than 10 per cent below the minimum values prescribed at point 75R (in the case of headlamps intended for left-hand traffic, the points to be considered are B50R, HV and 75L) or (b) By more than 10 per cent below the minimum values prescribed for HV in the case of a headlamp producing driving-beam only.
3.7.1.2.2.changed
In the case of Classes BS, CS, DS CS and ES, DS, after the test, the results of photometric measurements carried out on the headlamp in accordance with this Regulation shall not exceed: (a) By more than 30 per cent the maximum values prescribed at point HV and not be more than 10 per cent below the minimum values prescribed at point 50 L 50L and 50 R 50R for Class BS headlamp, 0.86D/3.5R, 0.86D/3.5L 0.86°D/3.5°R, 0.86°D/3.5°L for Classes CS, CS and DS and ES headlamp or (b) By more than 10 per cent below the minimum values prescribed for HV in the case of a headlamp producing driving beam driving-beam only.
3.7.2.changed
Test of adherence of coatings, if any The lens of sample No. 2 shall be subjected to the test described in paragraph 3.6. Annex 8
Annex 8 - Appendix 1changed
A. Tests on plastic materials (lenses or samples of material supplied pursuant to paragraph 1.2.). Table A8-1 Chronological order of material tests Samples Lenses or samples of material Lenses Tests 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Limited photometry X X X Temperature change X X X Limited photometry X X X Transmission measurement X X X X X X X X X Diffusion measurement X X X X X X Atmospheric agents X X X Transmission measurement X X X Chemical agents X X X Diffusion measurements X X X Detergents X X X Hydrocarbons X X X Transmission measurement X X X Deterioration X X X Transmission measurement X X X Diffusion measurement X X X Adherence X Resistance to light source X radiations* X * This test concerns front fog lamps equipped with gas-discharge light sources, headlamps and AFS. Annex 8 – Appendix 1 Table A8-2 Tests on complete devices, systems or parts thereof (supplied pursuant to paragraph 3.1.3.4. 3.1.2.4. of this Regulation) Complete devices, systems or parts therof Tests Sample No. 1 2 Deterioration X Photometry X Adherence X
1.changed
The beam of a collimator K with a half divergence β/2 = 17.4 x 104 rd 1.74∙105rd is limited by a diaphragm Dτ with an opening of 6 mm against which the sample stand is placed. A convergent achromatic lens L2, corrected for spherical aberrations links the diaphragm Dτ with the receiver R; the diameter of the lens L2 shall be such that it does not diaphragm the light diffused by the sample in a cone with a half top angle of β/2 = 14°. An annular diaphragm DD, with angles αo/2 = 1° and αmax /2 = 12° is placed in an image focal plane of the lens L2. The non-transparent central part of the diaphragm is necessary in order to eliminate the light arriving directly from the light source. It shall be possible to remove the central part of the diaphragm from the light beam in such a manner that it returns exactly to its original position. The distance L2 Dτ and the focal length F21 of the lens L2 shall be so chosen that the image of Dτ completely covers the receiver R. When the initial incident flux is referred to 1,000 units, the absolute precision of each reading shall be better than 1 unit. 1 For L2 it is recommended to use a focal distance of about 80 mm. Annex 8 – Appendix 2 Figure A8-I Optical set up for measurement of variations in diffusion and transmission
2.changed
The following readings shall be taken: 1 For L2 it is recommended to use a focal distance of about 80 mm. Table A8-3 Readings Reading With sample With central Quantity represented part of DD T1 No No Incident flux in initial reading T2 Yes No Flux transmitted by the new (before test) material in a field of (before test) 24° T3 Yes No Flux transmitted by the tested (after test) material in a field (after test) of 24° T4 Yes Yes Flux diffused by the new material (before test) T5 Yes Yes Flux diffused by the tested material (after test)
1.1.changed
The spray gun used shall be equipped with a nozzle 1.3 mm in diameter allowing a liquid flow rate of 0.24 ± 0.02 l/minute at an operating pressure of 6.0 bars -0/+0.5 bar. Under these operation conditions the fan pattern obtained shall be 170 mm ± 50 mm in diameter on the surface exposed to deterioration, at a distance of 380 mm 380mm ± 10 mm from the nozzle.
1.2.changed
The test mixture shall be composed of: (a) Silica sand of hardness 7 on the Mohr scale, with a grain size between 0 and 0.2 mm and an almost normal distribution, with an angular factor of 1.8 to 2; (b) Water of hardness not exceeding 205 g/m3 g/m 3 for a mixture comprising 25 g of sand per litre of water.
2.changed
The outer surface of the lamp lenses shall be subjected once or more than once to the action of the sand jet produced as described above. The jet shall be sprayed almost perpendicular to the surface to be tested. The deterioration shall be checked by means of one or more samples of glass placed as a reference near the lenses to be tested. The mixture shall be sprayed until the variation in the diffusion of light on the sample or samples measured by the method described in Appendix 2, is such that: T5 − T4 d   = = 0.0250  0.0025 T2 Several reference samples may be used to check that the whole surface to be tested has deteriorated homogeneously. Annex 8 – Appendix 4
4.changed
Before the test, the sample roll of adhesive tape shall be conditioned for 24 hours in the specified atmosphere (see para. 3. above). paragraph 3.). Five test pieces each 400 mm long shall be tested from each roll. These test pieces shall be taken from the roll after the first three turns were discarded.
3.2.1.changed
All samples shall be tested under the conditions as specified in paragraph 4.6.4. of this Regulation. If not specified differently in this Annex LED modules shall be tested inside the device as submitted by the manufacturer. Annex 9 paragraphs
4.6.2.1.1.added
and 4.6.2.2.1. of this Regulation.
3.2.2.changed
All samples For the measurement of electrical and photometric characteristics, the device shall be tested under the conditions as specified operated in paragraph 4.6.3. a dry and still atmosphere at an ambient temperature of this Regulation. 23 °C ± 5 °C.
4.1.1.changed
In addition to provisions as described in paragraph 4.16. of this Regulation. The minimum red content of the light of a LED module or a device incorporating LED module(s) module, when tested (at 50 V for headlamps and AFS) outside the device, shall be such that: 780 nm  E (  ) V (  ) () V() d  = 610 nm e k red = 780 nm  0.05  E (  ) V (  ) () V() d  380 =380 nm e where: Ee() (unit: W) is the spectral distribution of the irradiance; V() (unit: 1) is the spectral luminous efficiency; () (unit: nm) is the wavelength. This value shall be calculated using intervals of one nanometre.
4.2.changed
The UV-radiation of a low-UV-type LED module module, when tested outside the device, shall be such that: 400 nm  E ( ) S ( ) d    250nm = 250 nm e k UV = 780 nm  10 5 −5 W / lm km  E ( ) V ( ) d    380nm = 380 nm e where: S() (unit: 1) is the spectral weighting function; km = 683 lm/W is the maximum value of the luminous efficacy of radiation. (For definitions of the other symbols see paragraph 4.1.1.). This value shall be calculated using intervals of one nanometre. The UV-radiation shall be weighted according to the values as indicated in Table A9- 1: A9-1: Table A9-1 Table UV Values according to "IRPA/INIRC Guidelines on limits of exposure to ultraviolet radiation". Wavelengths (in nanometres) chosen are representative; other values should be interpolated.  S()  S()  S() 250 0.430 305 0.060 355 0.000 16 255 0.520 310 0.015 360 0.000 13 260 0.650 315 0.003 365 0.000 11 265 0.810 320 0.001 370 0.000 09 270 1.000 325 0.000 50 375 0.000 077 275 0.960 330 0.000 41 380 0.000 064 280 0.880 335 0.000 34 385 0.000 053 285 0.770 340 0.000 28 390 0.000 044 290 0.640 345 0.000 24 395 0.000 036 295 0.540 350 0.000 20 400 0.000 030 300 0.300
5.1.changed
The LED module(s) shall be in the configuration as described in the technical specification as defined in paragraph 3.1.3. 3.1.2.2. of this Regulation. Optical elements (secondary optics) shall be removed by the Technical Service at the request of the applicant by the use of tools. This procedure and the conditions during the measurements as described below shall be described in the test report.
5.2.changed
One module of each type shall be submitted by the applicant with the electronic light source control gear, if applicable, and sufficient instructions. Suitable thermal management (e.g. heat sink) may be provided, to simulate similar thermal conditions as in the corresponding headlamp or AFS application. Before the test each LED module shall be aged at least for seventy-two hours under the same conditions as in the corresponding headlamp application. In the case of use of an integrating sphere, the sphere shall have a minimum diameter of one meter, and at least ten times the maximum dimension of the LED module, whichever is the largest. The flux measurements can also be performed by integration using a goniophotometer. The prescriptions in CIE - Publication 84 - 1989, regarding the room temperature, positioning, etc., shall be taken into consideration. The LED module shall be burned in for approximately one hour in the closed sphere or goniophotometer. The flux shall be measured after photometric stability has occurred, as explained in paragraph 4.3.1.2. occurred.
1.1.added
The luminous intensity distribution and the colour of the light emitted are measured and checked for compliance after photometric stability (as defined in UN Regulation No. 48).
1.2.added
For lamps (functions) using light source technologies other than incandescent technology only:
1.2.1.added
10 minutes of operation, shall comply with the minimum and maximum requirements. The luminous intensity distribution after 1 and after 10 minutes of operation may be calculated from the luminous intensity distribution measured after photometric stability has occurred by applying at each test point the ratio of luminous intensities measured at 45°L 2.5°D for a left-side lamp (the L angle should be substituted for the R angle for a right-side lamp): (a) After 1 minute; (b) After 10 minutes; and (c) After photometric stability has occurred.
1.2.2.added
For all other lamps, the luminous intensities measured after 1 min and after photometric stability shall comply with the minimum and maximum requirements. The luminous intensity distribution after 1 min of operation may be calculated from the luminous intensity distribution after photometric stability by applying at each test point the ratio of luminous intensities measured at the test point according to Table A10-1 after 1 min and after photometric stability.
2.1.added
Depending on the light source technology and on the lamp (function) the luminous intensity distribution is, in addition to paragraph 1, checked for compliance at the point in time listed in Table A10-1. The luminous intensity distributions at a point in time may be calculated from the luminous intensity distribution measured after photometric stability by applying, at each test element in the light distribution, the ratio of luminous intensities measured at the test point of the lamp (function) under consideration. Table A10-1 Points in time for additional testing Lamp (function) Time after activation (seconds) Test point Driving-beam 1 HV (Headlamp producing only driving-beam) Passing-beam a 4 50V AFS class C a 4 50V Front fog 4 H, 2.5°D Cornering lamp 1 45°L 2.5°D resp. 45°R 2.5°D a After 1 second it shall meet at least 25 % of the requirement at the test point
2.1.1.added
In case a lamp (function) uses incandescent technology only, the lamp (function) is deemed to comply with the corresponding intensity requirements at all points in time, if the values measured after photometric stability are compliant.
2.1.2.added
In case a lamp (function) uses gas-discharge technology only, a lamp (function) is deemed to comply with the corresponding intensity requirements at all points in time, if the values measured at the point in time according to Table A10-1 and after photometric stability are compliant.
2.1.3.added
In case a lamp (function) uses LED technology only, a lamp (function) is deemed to comply with the corresponding intensity requirements at all points in time, if the values measured at 1 minute after activation and after photometric stability are compliant.
2.1.4.added
In case of any other light generating technology, the corresponding intensity requirements of a lamp (function) are tested and checked for compliance at all points in time starting at the corresponding point in time listed in Table A10-1 and ending when photometric stability is reached.
Annex 11changed
In the case it is required: used: Figure A11-I Centre of reference a = 2 mm min. This optional mark of the centre of reference shall be positioned on the lens at its intersection with the reference axis of the passing beam passing-beam and also on the lenses of the driving beams driving-beams and/or cornering lamps when they are neither grouped nor combined nor reciprocally incorporated with a passing beam passing-beam and on the lens of a front fog lamp. Figure A11-I represents the mark of the centre of reference as projected on a plane substantially tangent to the lens about the centre of the circle. The lines constituting this mark may either be solid or dotted.
Annex 12changed
The following marking relates to the requirements of paragraph 3.3.4.6. of this Regulation. Figure A12-I Figure A12-II A12 Voltage marking A Voltage marking B This marking must be placed on the main This marking must be placed on the main body of each headlamp containing only gas body of each headlamp containing at least one discharge light sources and ballast, and on gas discharge light source and ballast. each external part of the ballast. The ballast(s) road illumination device(s) is(are) designed for a network The ballast(s) is(are) designed for a network system rated voltage of nn Volts. system of nn Volts. None of the filament light sources which the headlamp contains is designed for a 24 Volts network system. Annex 13
Annex 13changed
The following approval mark marking arrangements are given merely as examples and any other arrangement made in accordance with paragraph 3.3. of this Regulation is acceptable.
1.changed
Figure A13-I - Marking example 1 The device bearing the approval mark marking shown on the left is an installation unit of an AFS approved in the Netherlands (E4) under approval number 19243 pursuant to this Regulation. The number after 149R indicates that approval was granted in accordance with the requirements of this Regulation in its original form (00). The functions identification symbols show that the approval was granted in respect of the driving-beam (R) and the Class C and Class V passing-beam. The double pointed arrow shows that the passing beam passing-beam is suitable for both traffic systems by means of an appropriate adjustment of the setting of the optical element or the light source on the vehicle. Class C passing-beam, Class V passing-beam and driving- beam comply to bending bend lighting provisions, as a = see para. 3.2.4.3. of this Regulation indicated by the letter "T". The score above the letter a = see Par. 3.3.1.2.1. of this Regulation "R" indicates that the driving-beam function is provided by more than one installation unit on that side of the system. Number 30 indicates that the maximum luminous intensity of the driving-beam is between 123,625 and 145,125 candelas. Figure A13-II - Marking example 2 The lamp bearing the approval mark marking shown on the left is a gas-discharge passing beam passing-beam headlamp (DC) (C) for left-hand traffic only (arrow) using a plastic lens (PL) approved in France (E2) Austria (E12) pursuant to this Regulation (149R) 149R as set in amended by the original 01 series of amendments (00) (01) combined with a front position lamp (A) as set in the original series of amendments (00) of the Regulation on Light Signalling Devices (148R). 148R. Both lamps (functions) are approved under approval number 3223.
2.changed
Note: The vertical and horizontal lines schematize the shape of the light- signalling lamp. These lines are not part of the approval mark. marking. Figure A13-III Marking example 3 Figure A13-IV 3-a Marking example 4 3-b Note: The examples 3-a and 3-b in Figures Figure A13-III and A13-IV correspond to a lighting device bearing an approval mark marking comprising: (a) A front position lamp approved in accordance with the 00 series of amendments to UN Regulation No. 148. The horizontal arrow indicates the side on which the required photometric specifications are met up to an angle of 80° H; (b) A headlamp, Class B, with a passing-beam designed for right-hand traffic only and a driving-beam with a maximum intensity comprised between 123,625 and 145,125 candelas (as indicated by the number 30), approved in accordance with the requirements of this Regulation, as amended by the 00 series of amendments and incorporating a lens of plastic material; (c) A front fog lamp approved in accordance with the 00 series of amendments of this Regulation and incorporating a lens of plastic material; (d) A front direction indicator lamp of category 1a approved in accordance with the 00 series of amendments to UN Regulation No. 148. Figure A13-IV Marking example 4 This example corresponds to an adaptive front-lighting system composed of two installation units for the left side of the vehicle and one installation unit for the right side. The system bearing the above approval markings meets the requirements of this Regulation (original version of the Regulation) in respect of both a passing-beam for left-hand traffic and a driving-beam with a maximum intensity comprised between 123,625 and 145,125 candelas (as indicated by the number 30) grouped with a front direction indicator lamp of category 1a and a front position lamp approved in accordance with the 00 series of amendments of UN Regulation No. 148. The installation unit 1 of the system (left side) is designed to contribute to the Class C passing-beam and the Class E passing-beam. The score above the letter "C" indicates that on that side more than one installation unit contributes to the Class C passing-beam. The letter "T" to the right following the listed symbols indicates that each, the Class C passing- beam and the Class E passing-beam are providing a bending mode. The installation unit 3 of the system (left side) is designed to provide the second part of the Class C passing-beam of that side (as indicated by the score above the letter "C") and a Class W passing-beam. For this additional lighting unit, a circle surrounding the letter "E" followed by the distinguishing number of the country is not necessary. The installation unit 2 of the system (right side) is designed to contribute to the Class C passing-beam, a Class E passing-beam, both with bending mode and a Class W passing- beam. Note: In the above example, the different installation units of the system shall bear the same approval number.
3.changed
Figure A13-V Light source module marking example MD E3 17325 Annex 13 The light source module bearing the identification code shown in Figure A13- V has been approved together with a lamp approved in Italy (E3) under approval number 17325.
4.changed
Figure A13-VI Lighting unit marking example ALU E43 1234 The additional lighting unit bearing the identification code shown in Figure A13-VI has been approved together with a headlamp initially approved in Japan (E43) under approval number 1234. Annex 14
Annex 14changed
Maximum format: A4 (210 x 297 mm) Adaptive front-lighting system description form No. 1 AFS control signals relevant to the lighting functions, and modes of functions provided by the system Function/mode(s) of, being influenced by the signal1 signal 1 Passing-beam Driving-beam Technical characteristics2 Class W Class C Class V Class E AFS Control Signal (use separate sheet, if needed) None / default X V-Signal E-Signal W-Signal T-Signal Other Signals3 1 Mark in the respective box(es) with an cross (X) the combination(s) which apply. 2 To be indicated in terms of: (a) Physical nature (electrical current/ voltage, optical, mechanical, hydraulic, pneumatic, ...). (b) Information type (continuous/analogous, binary, digitally coded,..). (c) Time dependent properties (time constant, resolution, ..). (d) Signal status when the respective conditions according to paragraph 6.22.7.4. of UN Regulation No. 48 are fulfilled. (e) Signal status in case of failure (with reference to the system input). 3 According to the applicants description; use separate sheet, if needed. Adaptive front-lighting system description form No. 2 Cut-off status, adjustment devices and adjustment procedures relevant to the lighting units Cut-off status5 Adjustment device The lighting unit provides or contributes to one or vertical horizontal or more passing-beam cut-off(s), Characteristics & additional provisions(if any)8 and provisions of linked to linked to Individual Individual Lighting as defined in Annex 5 paragraph 5.3.5.1. of "master" "master" ("master")6, 9 ("master")6 ,9 unit No.4 5 to this Regulation 6 this Regulation apply6 unit No.7 unit No.7 4 Designation of each individual lighting unit of the system as indicated in Annex 1 to this Regulation and as shown in the drawing according to paragraph 3.1.2. of this Regulation; use separate sheet(s) if needed. 5 Relevant to provisions of paragraph 6.22.6.1.2. of UN Regulation No. 48. 6 Strike out what does not apply. 7 Indicate corresponding lighting unit(s) number(s), if applicable. 8 Information such as e.g.: the order of adjustment of lighting units or assemblies of lighting units, any additional provisions for the adjustment process. 9 The adjustment of a "master" lighting unit may also adjust (an) other lighting unit(s). Annex 14 "