Skip to content
UN R37 Latest version

Uniform provisions concerning the approval of filament light sources for use in approved lamps of power-driven vehicles and of their trailers

Ask about UN R37

1.Scope

This Regulation applies to filament lamps shown in Annex 1 and intended for use in approved lamp units of power-driven vehicles and of their trailers.

2.Administrative provisions

2.1.

Definitions

2.1.1.

Definition of "category"

The term "category" is used in this Regulation to describe different basic design of standardised filament lamps. Each category has a specific designation, as for example: "H4", "P21W", "T4W", "PY21W"or "RR10W".

2.1.2.

Definition of "type"

Filament lamps of different1 "types" are filament lamps within the same category which differ in such essential respects as:

2.1.2.1.

Trade name or mark (Filament lamps bearing the same trade name or mark but produced by different manufacturers are considered as being of different types. Filament lamps produced by the same manufacturer differing only by the trade name or mark may be considered to be of the same type);

2.1.2.2.

Bulb design and/or cap design, in so far as these differences affect the optical results;

2.1.2.3.

Rated voltage;

2.1.2.4.

Halogen.

2.2.

Application for approval

2.2.1.

Application for approval shall be submitted by the owner of the trade name or mark, or by his duly accredited representative.

2.2.2.

Every application for approval shall be accompanied (see also paragraph 2.4.2.) by:

2.2.2.1.

Drawings in triplicate, sufficiently detailed to permit identification of the type;

2.2.2.2.

A brief technical description;

2.2.2.3.

Five samples of each colour which has been applied for;

2.2.3.

In the case of a type of filament lamp differing only by the trade name or mark from a type that has already been approved it shall be sufficient to submit:

A selective-yellow bulb or an additional selective-yellow outer bulb, solely intended to change the colour but not the other characteristics of a filament lamp emitting white light, does not constitute a change of type of the filament lamp.

2.2.3.1.

A declaration by the manufacturer that the type submitted is identical (except in the trade name or mark) with and has been produced by the same manufacturer as, the type already approved, the latter being identified by its approval code;

2.2.3.2.

Two samples bearing the new trade name or mark.

2.2.4.

The competent authority shall verify the existence of satisfactory arrangements for ensuring effective control of the conformity of production before type approval is granted.

2.3.

Inscriptions

2.3.1.

Filament lamps submitted for approval shall bear on the cap or bulb2:

2.3.1.1.

The trade name or mark of the applicant;

2.3.1.2.

The rated voltage. However, for filament lamps for which only a 12 V type is standardised and the maximum allowed bulb diameter of which does not exceed 7.5 mm, the rated voltage need not be marked;

2.3.1.3.

The international designation of the relevant category. The wattage character "W" of this designation need not be marked when the maximum allowed bulb diameter of the filament lamp type does not exceed 7.5 mm;

2.3.1.4.

The rated wattage (in the sequence, high wattage/low wattage filament for dual-filament lamps); this need not be indicated separately if it is part of the international designation of the relevant filament lamp category;

2.3.1.5.

A space of sufficient size to accommodate the approval mark.

2.3.2.

The space mentioned in paragraph 2.3.1.5. above shall be indicated in the drawings accompanying the application for approval.

2.3.3.

Halogen filament lamps meeting the requirements of paragraph 3.7. below shall be marked with a "U".

2.3.4.

Inscriptions other than those covered by paragraphs 2.3.1. and 2.4.3. may be affixed, on the condition that they do not adversely affect the luminous characteristics.

2.4.

Approval

2.4.1.

If all samples of a type of filament lamp which are submitted in pursuance of paragraphs 2.2.2.3. or 2.2.3.2. above meet the requirements of this Regulation, approval shall be granted.

2.4.2.

An approval code shall be assigned to each type approved. Its first character (at present 2, corresponding to the 02 series of amendments which entered into force on 27 October 1983 and to the 03 series of amendments (not requiring changes in the approval number), which entered into force on 1 June 1984) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. This will be followed by an identification code comprising not more than two characters. Only the Arabic numerals and capital letters listed in footnote3 shall be used. The same Contracting Party

In the latter case, the luminous characteristics shall not be adversely affected. 0123456789 ABCDEFGHJKLMNPRSTUVWXYZ

may not assign the same code to another type of filament lamp. Notice of approval or of extension or refusal or withdrawal of approval or production definitively discontinued of a type of filament lamp pursuant to this Regulation shall be communicated to the Parties of the Agreement which apply this Regulation by means of a form conforming to the model in Annex 2 to this Regulation and of a drawing, supplied by the applicant for approval in a format not exceeding A4 (210 x 297 mm) and on a scale of at least 2: 1. If the applicant so desires, the same approval code may be assigned to the filament lamp emitting white light and to the filament lamp emitting selective-yellow light (see para. 2.1.2.3.).

2.4.3.

To every filament lamp conforming to a type approved under this Regulation there shall be affixed in the space referred to in paragraph 2.3.1.5., in addition to the inscriptions required under paragraph 2.3.1., an international approval mark consisting of:

2.4.3.1.

A truncated circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval4;

2.4.3.2.

The approval code, placed close to the truncated circle.

2.4.4.

If the applicant has obtained the same approval code for several trade names or marks, one or more of them will suffice to meet the requirements of paragraph 2.3.1.1.

2.4.5.

The marks and inscriptions specified in paragraphs 2.3.1. and 2.4.3. shall be clearly legible and be indelible.

2.4.6.

Annex 3 to this Regulation gives an example of arrangement of the approval mark.

3.Technical requirements

3.1.

Definitions

3.1.1.

Rated voltage: voltage (in volts) marked on the filament lamp;

3.1.2.

Rated wattage: wattage (in watts) marked on the filament lamp which may be incorporated into the international designation of the relevant category;

3.1.3.

Test voltage: voltage, at the filament lamp terminals for which the electrical and photometric characteristics of the filament lamp are intended and are to be tested.

3.1.4.

Objective values: values to be achieved, within the specified tolerances, when the filament lamp is supplied with current at its test voltage;

3.1.5.

Standard (étalon) filament lamp: a filament lamp emitting white or amber or red light with reduced dimensional tolerances, used for the photometric testing of lighting and light-signalling devices. Standard filament lamps are specified in only one voltage rating for each category;

The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document TRANS/WP.29/78/Rev.2/Amend.1.

3.1.6.

Reference luminous flux: specified luminous flux of a standard filament lamp to which the optical characteristics of a lighting device shall be referred;

3.1.7.

Measuring luminous flux: specified value of the luminous flux for testing a filament lamp in a standard headlamp as specified in paragraph 3.8.;

3.1.8.

Reference axis: an axis defined with reference to the cap and to which certain dimensions of the filament lamp are referred;

3.1.9.

Reference plane: a plane defined with reference to the cap and to which certain dimensions of the filament lamp are referred.

3.1.10.

Filament light source (filament lamp): a light source where the element for visible radiation is one or more heated filaments producing thermal radiation.

3.2.

General specifications

3.2.1.

Each sample submitted shall conform to the relevant specifications of this Regulation.

3.2.2.

Filament lamps shall be so designed as to be and to remain in good working order when in normal use. They shall moreover exhibit no fault in design or manufacture.

3.2.3.

The filament(s) as specified in the data sheet of the relevant category in Annex 1 shall be the only element(s) of the filament lamp that generate and emit light when energised.

3.3.

Manufacture

3.3.1.

Filament lamp bulbs shall exhibit no scores or spots which might impair their efficiency and their optical performance.

3.3.2.

Filament lamps shall be equipped with standard caps complying with the cap data sheets of IEC Publication 60061, third edition, as specified on the individual data sheets of Annex 1.

3.3.3.

The cap shall be strong and firmly secured to the bulb.

3.3.4.

To ascertain whether filament lamps conform to the requirements of paragraphs 3.3.1. to 3.3.3. above, a visual inspection, a dimension check and, where necessary, a trial fitting shall be carried out.

3.4.

Tests

3.4.1.

Filament lamps shall first be aged at their test voltage for approximately one hour. For dual-filament lamps, each filament shall be aged separately. In the case of filament lamps, for which more than one test voltage is specified, the highest test voltage value shall be used for ageing.

3.4.2.

In the case of a filament lamp having a coated bulb, after the ageing period corresponding to paragraph 3.4.1., the surface of the bulb shall be lightly wiped with a cotton cloth soaked in a mixture of 70 vol. per cent of n-heptane and 30 vol. per cent of toluol. After about five minutes, the surface shall be inspected visually. It shall not show any apparent changes.

3.4.3.

The position and dimensions of the filament shall be measured with the filament lamps being supplied with current at from 90 per cent to 100 per cent of the test voltage. In the case of filament lamps, for which more than one test voltage is specified, the highest test voltage value shall be used for measurement of the position and dimensions of the filament.

3.4.4.

Unless otherwise specified, electrical and photometric measurements shall be carried out at the test voltage(s).

3.4.5.

Electrical measurements shall be carried out with instruments of at least class 0.2.

3.4.6.

The luminous flux (in lumen) specified on the filament lamp data sheets of Annex 1 is valid for filament lamps emitting white light unless a special colour is stated there. In the case where the selective-yellow colour is allowed, the luminous flux of the filament lamp with the selective-yellow outer bulb shall be at least 85 per cent of the specified luminous flux of the relevant filament lamp emitting white light.

3.5.

Filament position and dimensions

3.5.1.

The geometric shapes of the filament shall in principle be as specified on the filament lamp data sheets of Annex 1.

3.5.2.

For line filaments the correct position and shape shall be checked as specified in the relevant data sheets.

3.5.3.

If the filament is shown on the filament lamp data sheet in at least one view as a point, the position of the luminous centre shall be determined in conformity with Annex 4.

3.5.4.

The length of a line filament shall be determined by its ends, defined - unless otherwise specified on the relevant data sheet - as the apices of the first and the last filament turn as seen in projection perpendicular to the reference axis of the filament lamp. Such an apex shall comply with the requirement that the angle formed by the legs shall not exceed 90°. In the case of coiled-coil filaments the apices of the secondary turns shall be taken into account.

3.5.4.1.

For axial filaments the extreme position of the apices considered shall be determined by rotating the filament lamp about its reference axis. The length shall then be measured in a direction parallel to the reference axis.

3.5.4.2.

For transverse filaments the filament axis shall be placed perpendicular to the direction of projection. The length shall be measured in a direction perpendicular to the reference axis.

3.6.

Colour

3.6.1.

The colour of the light emitted by the filament lamp shall be white unless otherwise specified on the relevant data sheet.

3.6.2.

The definitions of the colour of the light emitted, given in Regulation No. 48 and its series of amendments in force at the time of application for type approval, shall apply to this Regulation.

3.6.3.

The colour of the light emitted shall be measured by the method specified in Annex 5. Each measured value shall lie within the required tolerance area5. Moreover, in the case of filament lamps emitting white light, the measured values shall not deviate more than 0.020 unit in the x and/or y direction from

For Conformity of Production purposes of amber and red colour only, at least 80 per cent of the measuring results shall lie within the required tolerance area.

a point of choice on the Planckian locus (IEC Publication 15.2 Colorimetry, 1986). Filament lamps for use in light signalling devices shall meet the requirements as specified in paragraph 2.4.2. of IEC Publication 60809, Amendment 5 to Edition 2.

3.7.

UV radiation

The UV radiation of a halogen lamp shall be such that: 400 nm ∫ Ee()∙d =315 nm k1 = ____________________ ≤ 2 ∙ 10-4 W/lm 780 nm km ∙ ∫ Ee()∙V()∙d =380 nm

315 nm ∫ Ee()∙d =250 nm k2 = ____________________ ≤ 2 ∙ 10-6 W/lm 780 nm km ∙ ∫ Ee()∙V()∙d =380 nm where: Ee () (W/nm) is the spectral distribution of the radiant flux; V () (1) is the spectral luminous efficiency; km = 683 (lm/W) is the photometric radiation equivalent;  (nm) is the wave length. This value shall be calculated using intervals of five nanometres.

3.8.

Observation concerning selective-yellow colour

An approval of a filament lamp type under this Regulation may be granted, pursuant to paragraph 3.6. above, for a filament lamp emitting white light as well as selective-yellow light; Article 3 of the Agreement to which this Regulation is annexed shall not prevent the Contracting Parties from prohibiting, on vehicles registered by them, filament lamps emitting either white or selective-yellow light.

3.9.

Check on optical quality (Applies only to filament lamps of categories R2, H4 and HS1).

3.9.1.

This check on optical quality shall be carried out at a voltage such that the measuring luminous flux is obtained; the specifications of paragraph 3.4.6. are to be observed accordingly.

3.9.2.

For 12-Volt filament lamps emitting white light: The sample which most nearly conforms to the requirements laid down for the standard filament lamp shall be tested in a standard headlamp as specified in paragraph 3.9.5. and it shall be verified whether the assembly comprising the aforesaid headlamp and the filament lamp being tested meets the light- distribution requirements laid down for the passing beam in the relevant Regulation.

3.9.3.

For 6-Volt and 24-Volt filament lamps emitting white light: The sample which most nearly conforms to the nominal dimension values shall be tested in a standard headlamp as specified in paragraph 3.9.5. and it shall be verified whether the assembly comprising the aforesaid headlamp and the filament lamp being tested meets the light-distribution requirements laid down for the passing beam in the relevant Regulation. Deviations not exceeding 10 per cent of the minimum values will be acceptable.

3.9.4.

Filament lamps emitting selective-yellow light shall be tested in the same manner as described in paragraphs 3.9.2. and 3.9.3. in a standard headlamp as specified in paragraph 3.9.5. to ensure that the illumination complies with at least 85 per cent for 12-Volt filament lamps, and at least 77 per cent for 6-Volt and 24-Volt filament lamps, with the minimum values of the light- distribution requirements laid down for the passing beam in the relevant Regulation. The maximum illumination limits remain unchanged. In the case of a filament lamp having a selective-yellow bulb, this test shall be left out if the approval is also given to the same type of filament lamp emitting white light.

3.9.5.

A headlamp shall be deemed to be a standard headlamp if:

3.9.5.1.

It satisfies the pertinent conditions of approval;

3.9.5.2.

It has an effective diameter of not less than 160 mm;

3.9.5.3.

With a standard filament lamp it produces at the various points and in the various zones specified for the headlamp type concerned, illumination equal to:

3.9.5.3.1.

Not more than 90 per cent of the maximum limits;

3.9.5.3.2.

Not less than 120 per cent of the minimum limits prescribed for the headlamp type concerned.

3.10.

Standard filament lamps

Additional requirements for standard (étalon) filament lamps are given on the relevant data sheets of Annex 1. Bulbs of standard (étalon) filament lamps emitting white light shall not alter the CIE trichromatic coordinates of a luminous source having a colour temperature of 2,856 K by more than 0.010 units in the x and/or y direction. For standard (étalon) filament lamps emitting amber or red light, changes of the bulb temperature shall not affect the luminous flux which might impair photometric measurements of signalling devices.

4.Conformity of production

4.1.

Filament lamps approved to this Regulation shall be so manufactured as to conform to the type approved by meeting the inscriptions and technical requirements set forth in paragraph 3. above and Annexes 1, 3 and 4 to this Regulation.

4.2.

In order to verify that the requirements of paragraph 4.1. are met, suitable controls of the production shall be carried out.

4.3.

The holder of the approval shall in particular:

4.3.1.

Ensure existence of procedures for the effective control of the quality of products,

4.3.2.

Have access to the control equipment necessary for checking the conformity to each approved type,

4.3.3.

Ensure that data of test results are recorded and that related documents shall remain available for a period to be determined in accordance with the administrative service,

4.3.4.

Analyse the results of each type of test, applying criteria of Annex 7, in order to verify and ensure the stability of the product characteristics making allowance for variation of an industrial production,

4.3.5.

Ensure that for each type of filament lamp, at least the tests prescribed in Annex 6 to this Regulation are carried out,

4.3.6.

Ensure that any collecting of samples giving evidence of non-conformity with the type of test considered shall give rise to another sampling and another test. All the necessary steps shall be taken to re-establish the conformity of the corresponding production.

4.4.

The competent authority which has granted type-approval may at any time verify the conformity control methods applicable to each production unit.

4.4.1.

In every inspection, the test books and production survey records shall be presented to the visiting inspector.

4.4.2.

The inspector may take samples at random which will be tested in the manufacturer's laboratory. The minimum number of samples may be determined according to the results of the manufacturer's own verification.

4.4.3.

When the quality level appears unsatisfactory or when it seems necessary to verify the validity of the tests carried out in application of paragraph 4.4.2. above, the inspector shall select samples, to be sent to the Technical Service which has conducted the type approval tests.

4.4.4.

The competent authority may carry out any tests prescribed in this Regulation. Where the competent authority decides to carry out spot checks, criteria of Annexes 8 and 9 to this Regulation shall be applied.

4.4.5.

The normal frequency of inspection authorised by the competent authority shall be one every two years. In the case where negative results are recorded during one of these visits, the competent authority shall ensure that all necessary steps are taken to re-establish the conformity of production as rapidly as possible.

5.Penalties for non-conformity of production

5.1.

The approval granted in respect of a filament lamp pursuant to this Regulation may be withdrawn if the requirements are not met or if a filament lamp bearing the approval mark does not conform to the type approved.

5.2.

If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously granted, it shall forthwith so notify the other Contracting Parties applying this Regulation, by means of a communication form conforming to the model in Annex 2 to this Regulation.

6.Production definitively discontinued

If the holder of the approval completely ceases to manufacture a type of filament lamp approved in accordance with this Regulation, he shall so inform the Type Approval Authority which has granted the approval. Upon receiving the relevant communication, that Type Approval Authority shall inform thereof the other Parties to the 1958 Agreement applying this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.

7.

Names and addresses of the Technical Services responsible for conducting approval tests, and of Type Approval Authorities The Parties to the 1958 Agreement which apply this Regulation shall communicate to the United Nations secretariat the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, or production definitively discontinued issued in other countries, are to be sent.

8.Transitional provisions

8.1.

Approvals granted under the preceding series of amendments shall remain valid, except that for conformity of production, current production filament lamps shall comply with the requirements of the latest series of amendments starting 12 months from the date of application of this amendment 6. 8.2 The correspondence between the former designations and the new ones is indicated in the following table:

New designations in the 03 series Old designations of amendments

P25-1 P21W P25-2 P21/5W R19/5 R5W R19/10 R10W C11 C5W C15 C21W T8/4 T4W W10/5 W5W W10/3 W3W

The amended text of this paragraph was introduced by Supplement 14 to the 03 series of amendments. This supplement entered into force on 3 September 1997 and it also introduced in the text of the Regulation new paragraphs 2.3.3. and 3.7. and in Annex 1 new sheets HIR1 and PY27/7W.

8.3.

No filament lamps of the categories listed below shall be used in lamps submitted for type approval after the period following the entry into force of Supplements to 03 series of amendments, as indicated for each category in the table below:

Category Supplement Period

C21W 28 12 months P19W 37 60 months PC16W 37 60 months PCR16W 37 12 months PCY16W 37 60 months PR19W 37 12 months PR24W 37 12 months PSR19W 37 12 months PSR24W 37 12 months PY19W 37 60 months R2 28 12 months S1 28 12 months

8.4.

However, Contracting Parties applying this Regulation may continue to grant approvals for lamps in which filament lamps of categories listed below are used, provided that these lamps are intended as replacement parts for installation on vehicles in use for the period after entry into force of the Supplements to the 03 series of amendments as indicated below:

Category Supplement Period

C21W 28 unlimited P19W 37 unlimited PC16W 37 unlimited PCR16W 37 unlimited PCY16W 37 unlimited PR19W 37 unlimited PR24W 37 unlimited PSR19W 37 unlimited PSR24W 37 unlimited PY19W 37 unlimited R2 28 unlimited S1 28 unlimited

Annex 1

Annex 1 — Sheets* for filament lamps

List of categories of filament lamps, grouped and their sheet numbers:

Group 1

Without general restrictions:

Category Sheet number(s)

H1 H1/1 to 3 H3 H3/1 to 4 H4 H4/1 to 5 H7 H7/1 to 4 H8 H8/1 to 4 H8B H8/1 to 4 H9 *** H9/1 to 4 H9B *** H9/1 to 4 H10 H10/1 to 3 H11 H11/1 to 4 H11B H11/1 to 4 H12 H12/1 to 3 H13 H13/1 to 4 H13A H13/1 to 4 H14 H14/1 to 4 H15 H15/1 to 5 H16 H16/1 to 4 H16B H16/1 to 4 H21W ** H21W/1 to 2 H27W/1 H27W/1 to 3 H27W/2 H27W/1 to 3 HB3 HB3/1 to 4 HB3A HB3/1 to 4 HB4 HB4/1 to 4 HB4A HB4/1 to 4 HIR1 *** HIR1/1 to 3 HIR2 HIR2/1 to 3 HS1 HS1/1 to 5 HS2 HS2/1 to 3 HS5 HS5/1 to 4 HS5A ***** HS5A/1 to 3 HS6 **** HS6/1 to 4 PSX24W ** P24W/1 to 3 PSX26W ** PSX26W1 to 3 PX24W ** P24W/1 to 3 S2 S1/S2/1 to 2 S3 S3/1

Annex 1

Group 2

Only for use in signalling lamps, cornering lamps, reversing lamps and rear registration plate lamps:

Category Sheet number(s)

C5W C5W/1 H6W H6W/1 H10W/1 H10W/1 to 2 HY6W H6W/1 HY10W H10W/1 to 2 HY21W H21W/1 to 2 P13W P13W/1 to 3 P21W P21W/1 to 2 P21/4W P21/4W/1 (P21/5W/2 to 3) P21/5W P21/5W/1 to 3 P24W P24W/1 to 3 P27W P27W/1 to 2 P27/7W P27/7W/1 to 3 PR21W PR21W/1 (P21W/2) PR21/4W PR21/4W/1 (P21/5W/2 to 3) PR21/5W PR21/5W/1 (P21/5W/2 to 3) PR27/7W PR27/7W/1 (P27/7W/2 to 3) PS19W P19W/1 to 3 PS24W P24W/1 to 3 PSY19W P19W/1 to 3 PSY24W P24W/1 to 3 PW13W P13W/1 to 3 PW16W PC16W/1 to 3 PWR16W PC16W/1 to 3 PWY16W PC16W/1 to 3 PW19W P19W/1 to 3 PWR19W P19W/1 to 3 PWY19W P19W/1 to 3 PW24W P24W/1 to 3 PWR24W P24W/1 to 3 PWY24W P24W/1 to 3 PY21W PY21W/1 (P21W/2) PY24W P24W/1 to 3 PY27/7W PY27/7W/1 (P27/7W/2 to 3) R5W R5W/1 R10W R10W/1 RR5W R5W/1 RR10W R10W/1

Category Sheet number(s)

RY10W R10W/1 T1.4W T1.4W/1 T4W T4W/1 W2.3W W2.3W/1 W3W W3W/1 W5W W5W/1 W10W W10W/1 W15/5W W15/5W/1 to 3 W16W W16W/1 W21W W21W/1 to 2 W21/5W W21/5W/1 to 3 WP21W WP21W/1 to 2 WPY21W WP21W/1 to 2 WR5W W5W/1 WR21/5W WR21/5W/1 (W21/5W/2 to 3) WY2.3W WY2.3W/1 WY5W W5W/1 WY10W W10W/1 WY16W W16W/1 WY21W WY21W/1 to 2

Annex 1

Group 3

For replacement purposes only (see transitional provisions of paragraphs 8.3. and 8.4.):

Category Sheet number(s)

C21W C21W/1 to 2 P19W P19W/1 to 3 PC16W PC16W/1 to 3 PCR16W PC16W/1 to 3 PCY16W PC16W/1 to 3 PR19W P19W/1 to 3 PR24W P24W/1 to 3 PSR19W P19W/1 to 3 PSR24W P24W/1 to 3 PY19W P19W/1 to 3 R2 R2/1 to 3 S1 S1/S2/1 to 2

* Tables, Electrical and Photometric characteristics: Voltage is expressed in V; Wattage is expressed in W; Luminous flux is expressed in lm. In a case that for a category of filament lamp more than one value of reference luminous flux is specified, the value at approximately 12 V for approval of a lighting device and 13.5 V for approval of a light-signalling device shall be applied unless otherwise specified by the regulation used for the approval of the device. ** Not for use in passing beam headlamps. *** Not for use in front fog lamps marked "B" as defined in Regulation No. 19. **** Not for use in Regulation No. 112 headlamps. ***** Not for use in headlamps other than Regulation No.113 class C headlamps.

List of sheets for filament lamps and their sequence in this annex:

Sheet number(s)

C5W/1 C21W/1 to 2 H1/1 to 3 H3/1 to 4 H4/1 to 5 H7/1 to 4 H8/1 to 4 H9/1 to 4 H10/1 to 3 H11/1 to 4 H12/1 to 3 H13/1 to 4 H14/1 to 4 H15/1 to 5 H16/1 to 4 H6W/1 H10W/1 to 2 H21W/1 to 2 H27W/1 to 3 HB3/1 to 4 HB4/1 to 4 HIR1/1 to 3 HIR2/1 to 3 HS1/1 to 5 HS2/1 to 3 HS5/1 to 4 HS5A/1 to 3 HS6/1 to 4 P13W/1 to 3 P19W/1 to 3 P21W/1 to 2 P21/4W/1 P21/5W/1 to 3 P24W/1 to 3 P27W/1 to 2 P27/7W/1 to 3 PC16W/1 to 3 PR21W/1

Annex 1

Sheet number(s)

PR21/4W/1 PR21/5W/1 PR27/7W/1 PSX26W/1 to 3 PY21W/1 PY27/7W/1 R2/1 to 3 R5W/1 R10W/1 S1/S2/1 to 2 S3/1 T1.4W/1 T4W/1 W2.3W/1 W3W/1 W5W/1 W10W/1 W15/5W/1 to 3 W16W/1 W21W/1 to 2 W21/5W/1 to 3 WP21W/1 to 2 WR21/5W/1 WY2.3W/1 WY21W/1 to 2

Category C5W Sheet C5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

b 1/ 34.0 35.0 36.0 35.0  0.5 2/,3/ 4/ 5/ f 7.5 15 9  1.5 Cap SV8.5 in accordance with IEC Publication 60061 (sheet 7004-81-4)

Electrical and photometric characteristics

Volts 6 12 24 12 Rated values Watts 5 5 Test voltage Volts 6.75 13.5 28.0 13.5

Objective Watts 5.5 max. 7.7 max. 5.5 max. values Luminous flux 45  20 % Reference luminous flux: 45 lm at approximately 13.5 V 1/ This dimension corresponds to a distance between two apertures of 3.5 mm diameter each bearing against one of the caps. 2/ The filament shall be housed in a cylinder 19 mm long co-axial with the filament lamp and placed symmetrically about the filament lamp centre. The diameter of the cylinder is for 6 V and 12 V filament lamps: d + 4 mm (for standard filament lamps: d + 2 mm) and for 24 V filament lamps: d + 5 mm, "d" being the nominal diameter of the filament as stated by the manufacturer. 3/ The deviation of the filament centre from the centre of the filament lamp shall not be more than ±2.0 mm (for standard filament lamps: ±0.5 mm) measured in the direction of the reference axis. 4/ 4.5 mm for 6 V filament lamps. 5/ 16.5 mm for 24 V filament lamps.

Annex 1

Category C21W Sheet C21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamp for reversing lamp only

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

b 1/ 40.0 41.0 42.0 41.0  0.5 f 2/ 7.5 10.5 8  1.0 Cap SV8.5 in accordance with IEC Publication 60061 (sheet 7004-81-4)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 21 21 Test voltage Volts 13.5 13.5

Objective Watts 26.5 max. 26.5 max. values Luminous flux 460  15 % Reference luminous flux: 460 lm at approximately 13.5 V 1/ This dimension corresponds to a distance between two apertures of 3.5 mm diameter. 2/ The position of the filament is checked by means of a "Box-System"; sheet C21W/2.

Category C21W Sheet C21W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and to the centre of the filament lamp's length, whether a filament lamp complies with the requirements.

12 V a h k

Filament lamps of normal production 4.0 + d 14.5 2.0

Standard filament lamp 2.0 + d 14.5 0.5

d = nominal filament diameter as stated by the manufacturer.

Test procedure and requirements

1.

The filament lamp is placed in a holder (socket) capable of being so rotated through 360° about the reference axis that the front elevation is seen on the screen on to which the image of the filament is projected. The reference plane on the screen shall coincide with the centre of the filament lamp. The central axis sought on the screen shall coincide with the centre of the filament lamp length.

2.Front elevation

2.1.

The projection of the filament shall lie entirely within the rectangle when the filament lamp is rotated through 360°.

2.2.

The centre of the filament shall not be offset by more than distance "k" from the central axis sought.

Annex 1

Category H1 Sheet H1/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference axis is perpendicular to the reference plane and passes through the point defined by the dimensions marked with 1. 2/ Both current lead-in electrodes shall be positioned in the bulb, the longer electrode above the filament (the filament lamp being viewed as shown in the figure). The internal design should be then such that stray light images and reflections are reduced to the minimum, e.g. by fitting cooling jackets over the non-coiled parts of the filament. 3/ The cylindrical portion of the bulb over length "f" shall be such as not to deform the projected image of the filament to such an extent as appreciably to affect the optical results. 4/ The colour of the light emitted shall be white or selective-yellow.

Category H1 Sheet H1/2

Filament lamps of normal production Standard filament lamp

Dimensions in mm 6V 12 V 24 V 12 V 6/,10/ 9/ e 25.0 25.0  0.15

f 6/,10/ 4.5  1.0 5.0  0.5 5.5  1.0 5.0 + 0.50 / -0.00

g 7/,8/ 0.5 d  0.5 d 0.5 d  0.25 d 9/ h1 0  0.20 5/ 9/ h2 0  0.25 5/

 45  12 45  3

Cap P14.5s in accordance with IEC Publication 60061 (sheet 7004-46-2)

Electrical and photometric characteristics

Volts 6 12 24 12 Rated values Watts 55 70 55

Test Voltage Volts 6.3 13.2 28.0 13.2

Watts 63 max. 68 max. 84 max. 68 max. Objective Luminous flux 1,350 1,550 1,900 values % 15

12 V 1,150 Reference luminous flux at approximately 13.2 V 1,550 5/ The eccentricity is measured only in the horizontal and vertical directions of the filament lamp as shown in the figure. The points to be measured are those where the projections of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 6/ The viewing direction is the perpendicular to the reference axis contained in the plane defined by the reference axis and the centre of the second pin of the cap. 7/ Offset of filament in relation to bulb axis measured at 27.5 mm from the reference plane. 8/ d: diameter of filament. 9/ To be checked by means of a "Box System", sheet H1/3. 10/ The ends of the filament are defined as the points where, when the viewing direction is as defined in footnote 6/ above, the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the reference axis.(special instructions for coiled-coil filaments are under consideration).

Annex 1

Category H1 Sheet H1/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

a1 a2 b1 b2 c1 c2

6V 6 3.5

12 V 1.4d 1.9 d 0.25 6 4.5

24 V 7 4.5 d = diameter of filament.

The filament position is checked solely in directions A and B as shown on sheet H1/1. The filament shall lie entirely within the limits shown. The beginning of the filament as defined on sheet H1/2, footnote 10/, shall lie between lines Z1 and Z2.

Category H3 Sheet H3/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The colour of the light emitted shall be white or selective-yellow. 2/ Minimum length above the height of the light emitting centre ("e") over which the bulb shall be cylindrical. 3/ The distortion of the base-end portion of the bulb shall not be visible from any direction outside the obscuration angle of 80° max. The shields shall produce no inconvenient reflections. The angle between the reference axis and the plane of each shield, measured on the bulb side, shall not exceed 90°.

Annex 1

Category H3 Sheet H3/2

4/ The permissible deviation of the ring centre from the reference axis is 0.5 mm in the direction perpendicular to the Z-Z line and 0.05 mm in the direction parallel to the Z-Z line. 5/ The cap shall be pressed in these directions.

Category H3 Sheet H3/3

Filaments lamps of normal production Standard filament lamp

Dimensions in mm 6V 12 V 24 V 12 V

e 18.0 6/ 18.0 f 8/ 3.0 min. 4.0 min. 5.0  0.50 k 0 6/ 0  0.20 h1, h3 0 6/ 0  0.15 7/ h2, h4 0 6/ 0  0.25 7/ Cap PK22s in accordance with IEC Publication 60061 (sheet 7004-47-4)

Electrical and photometric characteristics

Volts 6 12 24 12 Rated values Watts 55 70 55 Test voltage Volts 6.3 13.2 28.0 13.2 Watts 63 max. 68 max. 84 max. 68 max. Objective Luminous flux 1,050 1,450 1,750 values % 15 12 V 1,100 Reference luminous flux at approximately 13.2 V 1,450 6/ To be checked by means of a "Box-System"; sheet H3/4. 7/ For standard filament lamps the points to be measured are those where the projection of the outside of the end turns crosses the filament axis. 8/ The positions of the first and the last turn of the filament are defined by the intersections of the outside of the first and of the last light emitting turn, respectively, with the plane parallel to and 18 mm distant from the reference plane. (Additional instructions for coiled-coil filament are under consideration).

Annex 1

Category H3 Sheet H3/4

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament complies with the requirements.

a c k g

6V 2.0

12 V 1.8 d 1.6 d 1.0 2.8

24 V 2.9 d = diameter of filament

The filament shall lie entirely within the limits shown. The centre of the filament shall lie within the limits of dimension k.

Category H4 Sheet H4/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane formed by the seating points of the three lugs of the cap ring. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the circle of diameter "M". 3/ The colour of the light emitted shall be white or selective-yellow. 4/ The bulb and supports shall not exceed the envelope as in Figure 2. However, where a selective-yellow outer bulb is used the bulb and supports shall not exceed the envelope as in Figure 3. 5/ The obscuration shall extend at least as far as the cylindrical part of the bulb. It shall also overlap the internal shield when the latter is viewed in a direction perpendicular to the reference axis.

Annex 1

Category H4 Sheet H4/2

Filament lamps of normal production Standard filament lamp

Dimensions in mm 12 V 24 V 12 V

e 28.5 +0.35/-0.25 29.0  0.35 28.5 + 0.20 / -0.00 p 28.95 29.25 28.95  max. 40° max. 40° Cap P43t in accordance with IEC Publication 60061 (sheet 7004-39-6) Electrical and photometric characteristics

Volts 12 6/ 24 6/ 12 6/ Rated values Watts 60 55 75 70 60 55 Test voltage Volts 13.2 28.0 13.2 Watts 75 max. 68 max. 85 max. 80 max. 75 max. 68 max. Objective Luminous flux 1,650 1,000 1,900 1,200 values % 15

Measuring flux 7/ lm - 750 - 800 12 V 1,250 750 Reference luminous flux at approximately 13.2 V 1,650 1,000 6/ The value indicated in the left hand column relate to the driving beam filament. Those indicated in the right- hand column relate to the passing beam filament. 7/ Measuring luminous flux for measuring according to paragraph 3.9. of this Regulation.

Category H4 Sheet H4/3

Annex 1

Category H4 Sheet H4/4

Table of the dimensions (in mm) referred to in the drawings on sheet H4/3

Tolerance

Filaments lamps of Standard filament Reference* Dimension** normal production lamp

12 V 24 V 12 V 24 V 12 V 24 V 12 V

a/26 0.8 0.35 0.20

a/23.5 0.8 0.60 0.20

b1/29.5 30.0 0 0.30 0.35 0.20

b1/33 b1/29.5 mv b1/30.0 mv 0.30 0.35 0.15

b2/29.5 30.0 0 0.30 0.35 0.20

b2/33 b2/29.5 mv b2/30.0 mv 0.30 0.35 0.15

c/29.5 30.0 0.6 0.75 0.35 0.20

c/33 c/29.5 mv c/30.0 mv 0.35 0.15

d min. 0.1 - - +0.35 +0.20 e 13/ 28.5 29.0 0.35 -0.25 -0.00

+0.50 +0.30 f 11/,12/,13/ 0.40 1.7 2.0 -0.30 -0.10

g/26 0 0.50 0.30

g/23.5 0 0.70 0.30

h/29.5 30.0 0 0.50 0.30

h/33 h/29.5 mv h/30.0 mv 0.35 0.20

IR 11/,14/ 4.5 5.25 0.80 0.40

IC 11/,14/ 5.5 5.25 0.50 0.80 0.35

p/33 Depends on the shape of the shield - -

q/33 (p+q)/2 0.60 0.30

* "../26" means dimension to be measured at the distance from the reference plane indicated in mm after the stroke. ** "29.5 mv" or "30.0 mv" means the value measured at a distance of 29.5 or 30.0 mm from the reference plane.

Category H4 Sheet H4/5

8/ Plane V-V is the plane perpendicular to the reference plane and passing through the reference axis and through the intersection of the circle of diameter "M" with the axis of the reference lug. 9/ Plane H-H is the plane perpendicular to both the reference plane and plane V-V and passing through the reference axis. 10/ 30.0 mm for the 24-Volt type. 11/ The end turns of the filament are defined as being the first luminous turn and the last luminous turn that are at substantially the correct helix angle. For coiled-coil filaments, the turns are defined by the envelope of the primary coil. 12/ For the passing beam filament, the points to be measured are the intersections, seen in direction 1, of the lateral edge of the shield with the outside of the end turns defined under footnote 11/. 13/ "e" denotes the distance from the reference plane to the beginning of the passing beam filament as defined above. 14/ For the driving beam filament the points to be measured are the intersections, seen in direction 1, of a plane, parallel to plane H-H and situated at a distance of 0.8 mm below it, with the end turns defined under footnote 11/.

Additional explanations to sheet H4/3 The dimensions below are measured in three directions: 1 For dimensions a, b1, c, d, e, f, IR and IC; 2 For dimensions g, h, p and q; 3 For dimension b2. Dimensions p and q are measured in planes parallel to and 33 mm away from the reference plane. Dimensions b1, b2, c and h are measured in planes parallel to and 29.5 mm (30.0 mm for 24 V filament lamps) and 33 mm away from the reference plane. Dimensions a and g are measured in planes parallel to and 26.0 mm and 23.5 mm away from the reference plane. Note: For the method of measurement, see Appendix E of IEC Publication 60809.

Annex 1

Category H7 Sheet H7/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the points on the surfaces of the holder on which the three supporting bosses of the cap ring will rest. 2/ The reference axis is perpendicular to the reference plane and crosses the intersection of the two perpendiculars as indicated in Figure 3. 3/ The colour of the light emitted shall be white or selective-yellow. 4/ Notes concerning the filament diameter.
(a) No actual diameter restrictions apply but the objective for future developments is to have d max. = 1.3 mm for 12 V and d max. = 1.7 for 24V filament lamps.
(b) For the same manufacturer, the design diameter of standard (étalon) filament lamp and filament lamp of normal production shall be the same. 5/ Glass bulb and supports shall not exceed the envelope as indicated in Figure 2. The envelope is concentric to the reference axis.

Category H7 Sheet H7/2

6/ Glass bulb shall be optically distortion free within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2. 7/ The obscuration shall extend at least to the cylindrical part of the bulb on the whole bulb top circumference. It shall moreover extend at least to a plane parallel to the reference plane where 3 crosses the outer bulb surface (view B as indicated on sheet H7/1). 8/ The internal design of the lamp shall be such that stray light images and reflections are only located above the filament itself seen from the horizontal direction. (View A as indicated in Figure 1 on sheet H7/1). No metal parts other than filament turns shall be located in the shaded area as seen in Figure 5.

Annex 1

Category H7 Sheet H7/3

Standard Filaments lamps of normal production filament lamp

Dimensions in mm 12 V 24 V 12 V

e 9/ 25.0 10/ 25.0  0.1 f 9/ 4.1 10/ 4.9 10/ 4.1  0.1 12/ g 0.5 min. u.c. 11/ 10/ h1 0 0  0.10 h2 11/ 0 10/ 0  0.15 1 40° min. 40° min. 2 50° min. 50° min. 3 30° min. 30° min. Cap PX26d in accordance with IEC Publication 60061 (sheet 7004-5-6)

Electrical and photometric characteristics

Rated Volts 12 24 12 values Watts 55 70 55 Test Volts 13.2 28.0 13.2 voltage Watts 58 max. 75 max. 58 max. Objective values Luminous 1,500  10 % 1,750  10 % flux 12 V 1,100 Reference luminous flux at approximately 13.2 V 1,500 9/ The ends of the filament are defined as the points where, when the viewing direction is direction A as shown in Figure 1 on sheet H7/1, the projection of the outside of the end turns crosses the filament axis. (Special instructions for coiled-coil filaments are under consideration). 10/ To be checked by means of a "Box System", sheet H7/4. 11/ The offset of the filament with respect to the reference axis is measured only in viewing directions A and B as shown in Figure 1 in sheet H7/1. The points to be measured are those where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 12/ Offset of filament in relation to bulb axis measured in two planes parallel to the reference plane where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis.

Category H7 Sheet H7/4

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements. Dimensions in mm

a1 a2 b1 b2 c1 c2

12 V d + 0.30 d + 0.50 0.2 4.6 4.0

24V d + 0.60 d + 1.00 0.25 5.9 4.4 d = diameter of filament

The filament position is checked solely in directions A and B as shown on sheet H7/1,

Figure 1 — .
Figure 2 — - Maximum lamp outline 3/
1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament;

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Annex 1

Categories H27W/1 and H27W/2 Sheet H27W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the plane formed by the underside of the bevelled lead-in flange of the cap. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the 13.10 mm cap diameter. 3/ Glass bulb and supports shall not exceed the size of a theoretical cylinder centred on the reference axis. 4/ The obscuration shall extend over the whole bulb top including the bulb cylindrical portion up to the intersection with 1.

Categories H27W/1 and H27W/2 Sheet H27W/2

Filament dimensions and position (Dimensions f for all filament lamps) (Dimensions h1, h2, h3, h4 and k for standard filament lamps only)

Dimensions in mm Filament lamp of normal production Standard filament lamp 6/ e 31.75 31.75  0.25 8/ f 4.8 max. 4.2  0.20 6/ k 0 0.0  0.25 h1, h2, h3, h4 7/ 0 6/ 0.0  0.25 5/ 1 38° nom. 38° nom. 5/ 2 44° nom. 44° nom. H27W/1: PG13 Cap: in accordance with IEC Publication 60061 (sheet 7004-107-4) H27W/2: PGJ13

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 27 27 Test voltage Volts 13.5 13.5 Objective Watts 31 max. 31 max. values Luminous flux 477  15 % 12 V 350 lm Reference luminous flux at approximately 13.2 V 450 lm 13.5 V 477 lm 5/ Glass bulb shall be optically distortion free within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2. 6/ To be checked by means of a "Box System", sheet H27W/3. 7/ For standard filament lamps, the points to be measured are those where the projection of the outside of the end turns crosses the filament axis. 8/ The ends of the filament are defined by the intersections of the outside of the first and of the last light emitting turn, respectively, with the plane parallel to and 31.75 mm from the reference plane.

Annex 1

Categories H27W/1 and H27W/2 Sheet H27W/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements. Dimensions in mm

Reference a c k g

Dimensions d + 1.2 d + 1.0 0.5 2.4 d = actual diameter of filament

The filament shall lie entirely within the limits shown. The centre of the filament shall lie within the limits of dimension k.

Categories HB3 and HB3A Sheet HB3/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane defined by the meeting points of cap-holder fit. 2/ The reference axis is perpendicular to the reference plane and concentric with the reference diameter of the cap. 3/ Glass bulb and supports shall not exceed the envelope and shall not interfere with insertion past the lamp key. 4/ The keyway is mandatory for category HB3A and optional for category HB3. 5/ The filament lamp shall be rotated in the measuring holder until the reference lug contacts plane C of the holder.

Annex 1

Categories HB3 and HB3A Sheet HB3/2

6/ The colour of the light emitted shall be white or selective-yellow. 7/ Glass bulb periphery shall be optically distortion-free axially within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2.

Categories HB3 and HB3A Sheet HB3/3

Tolerances

Filament lamps of normal Standard filament lamp Dimensions in mm 12/ production

e 9/, 11/ 31.5 10/  0.16 f 9/, 11/ 5.1 10/  0.16 10/ h1, h2 0  0.15 8/ 10/ h3 0  0.08 8/ 1 45° min. - - 2 52° min. - - Cap P20d in accordance with IEC Publication 60061 (sheet 7004-31-2) 13/

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 60 60 Test voltage Volts 13.2 13.2 Watts 73 max. 73 max. Objective values Luminous flux 1,860  12 % 12 V 1,300 Reference luminous flux at approximately 13.2 V 1,860 8/ The eccentricity is measured only in viewing directions* A and B as shown in the figure on sheet HB3/1. The points to be measured are those where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 9/ The viewing direction is direction* B as shown in the figure on sheet HB3/1. 10/ To be checked by means of a "Box-System"; sheet HB3/4*. 11/ The ends of the filament are defined as the points where, when the viewing direction* as defined in footnote 9/ above, the projection of the outside of the end turns crosses the filament axis. 12/ Dimensions shall be checked with O-ring removed. 13/ Filament lamp HB3 shall be equipped with the right-angle cap and filament lamp HB3A with the straight cap. * Manufacturers may choose another set of perpendicular viewing directions. The viewing directions specified by the manufacturer are to be used by the testing laboratory when checking filament dimensions and position.

Annex 1

Categories HB3 and HB3A Sheet HB3/4

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

p q r s t u v

12 V 1.3 d 1.6 d 3.0 2.9 0.9 0.4 0.7 d = diameter of filament

The filament position is checked solely in directions A and B as shown on sheet HB3/1. The filament shall lie entirely within the limits shown. The beginning of the filament, as defined on sheet HB3/3, footnote 11/, shall lie in volume "B" and the end of the filament in volume "C". Volume "A" does not involve any filament centre requirement.

Categories HB4 and HB4A Sheet HB4/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane defined by the meeting points of cap-holder fit. 2/ The reference axis is perpendicular to the reference plane and concentric with the reference diameter of the cap. 3/ Glass bulb and supports shall not exceed the envelope and shall not interfere with insertion past the lamp key. The envelope is concentric to the reference axis. 4/ The keyway is mandatory for category HB4A and optional for category HB4. 5/ The filament shall be rotated in the measuring holder until the reference lug contacts plane C of the holder.

Annex 1

Categories HB4 and HB4A Sheet HB4/2

6/ The colour of the light emitted shall be white or selective-yellow. 7/ Glass bulb periphery shall be optically distortion-free axially and cylindrically within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2 and does not need to be verified in the area covered by the obscuration. 8/ The obscuration shall extend to at least angle 3 and shall be at least as far as the undistorted part of the bulb defined by angle 1.

Categories HB4 and HB4A Sheet HB4/3

Tolerances

Filament lamps of normal Standard filament lamp Dimensions in mm 13/ production

e 10/, 12/ 31.5 11/ 0.16 f 10/, 12/ 5.1 11/ 0.16 11/ h1, h2 0 0.15 9/ 11/ h3 0 0.08 9/ g 10/ 0.75 0.5 0.3 1 50° min. - - 2 52° min. - - 3 45° 5° 5° Cap P22d in accordance with IEC Publication 60061 (sheet 7004-32-2) 14/

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 51 51 Test voltage Volts 13.2 13.2 Watts 62 max. 62 max. Objective values Luminous flux 1,095  15 % 12 V 825 Reference luminous flux at approximately 13.2 V 1,095 9/ The eccentricity is measured only in viewing directions* A and B as shown in the figure on sheet HB4/1. The points to be measured are those where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 10/ The viewing direction is direction* B as shown in the figure on sheet HB4/1. 11/ To be checked by means of a "Box-System"; sheet HB4/4*. 12/ The ends of the filament are defined as the points where, when the viewing direction* as defined in footnote 10/ above, the projection of the outside of the end turns crosses the filament axis. 13/ Dimensions shall be checked with O-ring removed. 14/ Filament lamp HB4 shall be equipped with the right-angle cap and filament lamp HB4A with the straight cap. * Manufacturers may choose another set of perpendicular viewing directions. The viewing directions specified by the manufacturer are to be used by the testing laboratory when checking filament dimensions and position.

Annex 1

Categories HB4 and HB4A Sheet HB4/4

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

p q r s t u v

12 V 1.3 d 1.6 d 3.0 2.9 0.9 0.4 0.7 d = diameter of filament

The filament position is checked solely in directions A and B as shown on sheet HB4/1. The filament shall lie entirely within the limits shown. The beginning of the filament as defined on sheet HB4/3 footnote 12/ shall lie in volume "B" and the end of the filament in volume "C". Volume "A" does not involve any filament centre requirement.

Category HIR1 Sheet HIR1/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane defined by the three supporting bosses on the cap flange. 2/ The reference axis is perpendicular to the reference plane and concentric with the reference diameter of the cap. 3/ Glass bulb and supports shall not exceed the envelope. The envelop is concentric to the reference axis. 4/ The keyway is mandatory. 5/ The filament shall be rotated in the measuring holder until the reference lug contacts plane C of the holder. 6/ Glass bulb periphery shall be optically distortion-free axially within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2.

Annex 1

Category HIR1 Sheet HIR1/2

Tolerances

Dimensions in mm 11/ Filament lamps of normal production Standard filament lamp 8/, 10/ 9/ e 29 0.16 f 8/, 10/ 5.1 9/ 0.16 g 8/ 0 +0.7 / -0.0 +0.4 / -0.0 9/ h1, h2 0 0.15 7/ d 1.6 max. 1 50° min. - - 2 50° min. - - Cap PX20d in accordance with IEC Publication 60061 (sheet 7004-31-2)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 65 65 Test voltage Volts 13.2 13.2 Watts 73 max. 73 max. Objective values Luminous flux 2,500  15 % 12 V 1,840 Reference luminous flux at approximately 13.2 V 2,500 7/ The eccentricity is measured only in viewing directions A and B as shown in the figure on sheet HIR1/1. The points to be measured are those where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 8/ The viewing direction is direction B as shown in the figure on sheet HIR1/1. 9/ To be checked by means of a "Box-System"; sheet HIR1/3. 10/ The ends of the filament are defined as the points where, when the viewing direction as defined in footnote 8/ above, the projection of the outside of the end turns crosses the filament axis. 11/ Dimensions shall be checked with O-ring mounted.

Category HIR1 Sheet HIR1/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

a1 a2 b1 b2 c1 c2

12 V d + 0.4 d + 0.8 0.35 6.1 5.2 d = diameter of filament

The filament position is checked solely in directions A and B as shown on sheet HIR1/1. The ends of the filament as defined on sheet HIR1/2 footnote 10/ shall lie between lines Z1 and Z2 and between lines Z3 and Z4.

Annex 1

Category HIR2 Sheet HIR2/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane defined by the three meeting points of the cap holder fit. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the reference diameter of the cap. 3/ Glass bulb and supports shall not exceed the envelope. The envelop is concentric to the reference axis. 4/ The keyway is mandatory. 5/ The filament lamp shall be rotated in the measuring holder until the reference lug contacts plane C of the holder. 6/ Glass bulb periphery shall be optically distortion-free axially within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2.

Category HIR2 Sheet HIR2/2

Tolerances

Dimensions in mm 11/ Filament lamps of normal production Standard filament lamp 8/, 10/ 9/ e 28.7 0.16 8/, 10/ 9/ f 5.3 0.16 g 8/ 0 +0.7 / -0.0 +0.4 / -0.0 9/ h1, h2 0 0.15 7/ d 1.6 max. - - 1 50° min. - - 2 50° min. - - Cap PX22d in accordance with IEC Publication 60061 (sheet 7004-32-2)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 55 55 Test voltage Volts 13.2 13.2 Watts 63 max. 63 max. Objective values Luminous flux 1,875  15 % 12 V 1,355 Reference luminous flux at approximately 13.2 V 1,875 7/ The eccentricity is measured only in viewing directions A and B as shown in the figure on sheet HIR2/1. The points to be measured are those where the projection of the outside of the end turns nearest to or furthest from the reference plane crosses the filament axis. 8/ The viewing direction is direction B as shown in the figure on sheet HIR2/1. 9/ To be checked by means of a "Box-System"; sheet HIR2/3. 10/ The ends of the filament are defined as the points where, when the viewing direction as defined in footnote 8/ above, the projection of the outside of the end turns crosses the filament axis. 11/ Dimensions shall be checked with O-ring removed.

Annex 1

Category HIR2 Sheet HIR2/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

a1 a2 b1 b2 c1 c2

12 V d + 0.4 d + 0.8 0.35 6.6 5.7 d = diameter of filament

The filament position is checked solely in directions A and B as shown on sheet HIR2/1. The ends of the filament as defined on sheet HIR2/2 footnote 10/ shall lie between lines Z1 and Z2 and between lines Z3 and Z4.

Category HS1 Sheet HS1/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is the plane formed by the seating points of the three lugs of the cap ring. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the circle of diameter "M". 3/ The colour of the light emitted shall be white or selective-yellow. 4/ The bulb and supports shall not exceed the envelope as in Figure 2. However, where a selective-yellow outer bulb is used the bulb and supports shall not exceed the envelope as in Figure 3. 5/ The obscuration shall extend at least as far as the cylindrical part of the bulb. It shall also overlap the internal shield when the latter is viewed in a direction perpendicular to the reference axis.

Annex 1

Category HS1 Sheet HS1/2

Filament lamps of normal production Standard filament lamp

Dimensions in mm 6V 12 V 12 V

e 28.5 + 0.45 / -0.25 28.5 + 0.20 / -0.00 p 28.95 28.95  max. 40° max. 40° Cap PX43t in accordance with IEC Publication 60061 (sheet 7004-34-2)

Electrical and photometric characteristics

Volts 6 6/ 12 6/ 12 6/ Rated values Watts 35 35 35 35 35 35 Test voltage Volts 6.3 13.2 13.2

Watts 35 35 35 35 35 35

% 5 5 Objective values Luminous 700 440 825 525 flux

% 15

Measuring flux 7/ lm - - 450 12 V 700 450 Reference luminous flux at approximately 13.2 V 825 525 6/ The values indicated in the left hand column relate to the driving beam. Those indicated in the right-hand column relate to the passing beam. 7/ Measuring luminous flux according to paragraph 3.9. of this Regulation.

Category HS1 Sheet HS1/3

Annex 1

Category HS1 Sheet HS1/4

Table of the dimensions (in mm) referred to in the drawings on sheet HS1/3

Tolerance

Filaments lamps of normal Standard filament lamp Reference* Dimensions** production

6V 12 V 6V 12 V 6V 12 V 12 V

a/26 0.8 0.35 0.20 a/25 0.8 0.55 0.20 b1/29.5 0 0.35 0.20 b1/33 b1/29.5 mv 0.35 0.15 b2/29.5 0 0.35 0.20 b2/33 b2/29.5 mv 0.35 0.15 c/29.5 0.6 0.35 0.20 c/31 c/29.5 mv 0.30 0.15 d min. 0.1 / max. 1.5 - - e 13/ 28.5 +0.45 / -0.25 +0.20 / -0.00 f 11/, 12/, 13/ 1.7 +0.50 / -0.30 +0.30 / -0.10 g/26 0 0.50 0.30

g/25 0 0.70 0.30

h/29.5 0 0.50 0.30

h/31 h/29.5 mv 0.30 0.20

lR 11/, 14/ 3.5 4.0 0.80 0.40

lC 11/, 12/ 3.3 4.5 0.80 0.35

p/33 Depends on the shape of the - - shield q/33 (p+q)/2 0.60 0.30

* "../26" means dimension to be measured at the distance from the reference plane indicated in mm after the stroke. ** "29.5 mv" means the value measured at a distance of 29.5 mm from the reference plane.

Category HS1 Sheet HS1/5

8/ Plane V-V is the plane perpendicular to the reference plane and passing through the reference axis and through the intersection of the circle of diameter "M" with the axis of the reference lug. 9/ Plane H-H is the plane perpendicular to both the reference plane and plane V-V and passing through the reference axis. 10/ (Blank). 11/ The end turns of the filament are defined as being the first luminous turn and the last luminous turn that are at substantially the correct helix angle. For coiled-coil filaments, the turns are defined by the envelope of the primary coil. 12/ For the passing beam filament, the points to be measured are the intersections, seen in direction 1 , of the lateral edge of the shield with the outside of the end turns defined under footnote 11/. 13/ "e" denotes the distance from the reference plane to the beginning of the passing beam filament as defined above. 14/ For the driving beam filament the points to be measured are the intersections, seen in direction 1 , of a plane, parallel to plane H-H and situated at a distance of 0.8 mm below it, with the end turns defined under footnote 11/.

Additional explanations to sheet HS1/3 The dimensions below are measured in three directions:

1 For dimensions a, b1, c, d, e, f, IR and IC; 2 For dimensions g, h, p and q; 3 For dimension b2. Dimensions p and q are measured in planes parallel to and 33 mm away from the reference plane. Dimensions b1 and b2 are measured in planes parallel to and 29.5 mm and 33 mm away from the reference plane. Dimensions a and g are measured in planes parallel to and 25.0 mm and 26.0 mm away from the reference plane. Dimensions c and h are measured in planes parallel to and 29.5 mm and 31 mm away from the reference plane. Note: For the method of measurement, see Appendix E of IEC Publication 60809.

Annex 1

Category HS2 Sheet HS2/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference axis is perpendicular to the reference plane and passes through the intersection of this plane with the axis of the cap ring. 2/ All parts which may obscure the light or may influence the light beam shall lie within angle . 3/ Angle  denotes the position of the plane through the inner leads with reference to the reference notch. 4/ In the area between the outer legs of the angles 1 and 2, the bulb shall have no optically distorting areas and the curvature of the bulb shall have a radius not less than 50 per cent of the actual bulb diameter.

Category HS2 Sheet HS2/2

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max. 5/ e 11.0 11.0  0.15 6V 1.5 2.5 3.0 2.5  0.15 f 6/ 12 V 2.0 3.0 4.0 5/ h1, h2 0  0.15  2/ 40°  3/ 75° 90° 105° 90°  5° 1 4/ 15° 15° min. 2 4/ 40° 40° min. Cap PX13.5s in accordance with IEC Publication 60061 (sheet 7004-35-2) Electrical and photometric characteristics

Volts 6 12 6 Rated values Watts 15 15 Test voltage Volts 6.75 13.5 6.75

Objective Watts 15  6 % 15  6 % values Luminous flux 320  15 % Reference luminous flux: 320 lm at approximately 6.75 V 5/ To be checked by means of the "box system", sheet HS2/3. 6/ In order to avoid rapid filament failure, the supply voltage shall not exceed 8.5 V for 6 V filament lamps and 15 V for 12 V types.

Annex 1

Category HS2 Sheet HS2/3

Screen projection requirements This test is used to determine, by checking whether the filament lamp complies with the requirements by checking whether the filament lamp is correctly positioned relative to the reference axis and reference plane.

Reference a1 a2 b1 b2 c1 (6 V) c1 (12V) c2

Dimension d + 1.0 d + 1.4 0.25 0.25 4.0 4.5 1.75 d= actual filament diameter

The filament shall lie entirely within the limits shown. The beginning of the filament shall lie between the lines Z1 and Z2.

Category HS5 Sheet HS5/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamp for motorcycles

1/ The reference plane is defined by the three ramp inside surface. 2/ The reference axis is perpendicular to the reference plane and passing through the centre of the 23 mm cap diameter. 3/ Glass bulb and supports shall not exceed the envelope as indicated in Figure 1. The envelope is concentric to the reference axis. 4/ Glass bulb shall be optically distortion free within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2. 5/ The obscuration shall extend at least to angle 3 and shall extend at least to the cylindrical part of the bulb on the whole top circumference.

Annex 1

Category HS5 Sheet HS5/2

Category HS5 Sheet HS5/3

Filament lamps of normal production Standard filament lamp

Dimensions in mm 12V 12V

e 26 0.15 lC 7/ 4.6 0.3 k 0 0.2 h1, h3 0 0.15 6/ h2, h4 0 0.20 7/ lR 4.6 0.3 j 0 0.2 g1, g3 0 0.30 g2, g4 2.5 0.40 γ1 50 min. - - γ2 23 min. - - γ3 50 min. - - Cap P23t in accordance with IEC Publication 60061 (sheet 7004-138-2)

Electrical and photometric characteristcs

Rated Voltage V 12 12 values Wattage W 35 30 35 30 Test voltage V 13.2 13.2 Wattage W 40 max. 37 max. 40 max. 37 max. Objective lm 620 515 Values Luminous flux % 15 15 12 V 460 380 Reference luminous at approximately 13.2 V 620 515 6/ To be checked by means of a "Box-System". Sheet HS5/4. 7/ The positions of the first and the last turn of the filament are defined by the intersections of the outside of the first and the outside of the last light-emitting turn, respectively, with the plane parallel to and 26 mm distant from the reference plane.

Annex 1

Category HS5 Sheet HS5/4

Screen projection requirement This test is used to determine whether a filament lamp complies with the requirements by checking whether:
(a) The passing beam filament is correctly positioned relative to the reference axis and the reference plane; and whether
(b) The driving beam filament is correctly positioned relative to the passing beam filament.

Reference a b c d v

Dimensions d1+0.6 d1+0.8 d2+1.2 d2+1.6 2.5 d1 : Diameter of the passing beam filament d2 : Diameter of the driving beam filament

Reference h k

Dimensions 6.0 0.5

The filaments shall lie entirely within the limits shown. The centre of the filament shall lie within the limits of dimension k.

Category HS5A Sheet HS5A/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamp for motorcycles

1/ The reference plane is defined by three ramps inside surface. 2/ The reference axis is perpendicular to the reference plane and passing through the centre of the 23 mm cap diameter. 3/ Glass bulb and supports shall not exceed the envelope as indicated in Figure 1. The envelope is concentric to the reference axis. 4/ Glass bulb shall be optically distortion free within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2. 5/ The obscuration shall extend at least to angle 3 and shall extend at least to the cylindrical part of the bulb on the whole top circumference.

Annex 1

Category HS5A Sheet HS5A/2 ___________________________________________________________________________________________________________

Category HS5A Sheet HS5A/3

Filament lamps of normal production Standard filament lamp

Dimensions in mm 12 V 12 V

e 26 - -

lC 6/ 4.6 0.5 0.3

k 0 0.4 0.2

h1, h3 0 0.3 0.15

h2, h4 0 0.4 0.2

lR 6/ 4.6 0.5 0.3

j 0 0.6 0.3

g1, g3 0 0.6 0.3

g2, g4 2.5 0.4 0.2

γ1 50 min. - -

γ2 23 min. - -

γ3 50 min. - -

Cap PX23t in accordance with IEC Publication 60061 (sheet 7004-138A-1)

Electrical and photometric characteristics

Voltage V 12 7/ 12 7/ Rated values Wattage W 45 40 45 40

Test voltage V 13.2 13.2

Wattage W 50 max. 45 max. 50 max. 45 max.

Objective Values Luminous lm 750 640 flux % 15 15

12 V 550 lm 470 lm Reference luminous at approximately 13.2 V 750 lm 640 lm 6/ The positions of the first and the last turn of the filament are defined by the intersections of the outside of the first and the outside of the last light-emitting turn, respectively, with the plane parallel to and 26 mm distant from the reference plane. 7/ The values indicated in the left-hand columns relate to the driving beam filament and those indicated in the right-hand columns to the passing beam filament.

Annex 1

Category HS6 Sheet HS6/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

3/

1/ The reference plane is the plane formed by the underside of the three radiused tabs of the cap. 2/ The reference axis is perpendicular to the reference plane and crosses the intersection of the two perpendiculars as indicated in Figure 2 on sheet HS6/2. 3/ Glass bulb and supports shall not exceed the envelope as indicated. The envelope is concentric to the reference axis. 4/ The filament lamp shall be rotated in the measuring holder until the reference lug contacts plane C of the holder. 5/ Plane V-V is the plane perpendicular to the reference plane passing through the reference axis and parallel to plane C.

Category HS6 Sheet HS6/2

6/ Glass bulb shall be optically distortion-free axially and cylindrically within the angles  and . This requirement applies to the whole bulb circumference within the angles  and  and does not need to be verified in the area covered by the opaque coating. 7/ The opaque coating shall extend at least to the cylindrical part of the bulb on the whole bulb top circumference. It shall moreover extend at least to a plane parallel to the reference plane where  crosses the outer bulb surface as shown in Figure 3 (view in direction B as indicated on sheet HS6/1). 8/ Offset of passing beam filament in relation to the bulb axis is measured in two planes parallel to the reference plane where the projection of the outside end turns nearest to and farthest from the reference plane crosses the passing beam filament axis. 9/ Light shall be blocked over the cap end of the bulb extending to angle . This requirement applies in all directions around the reference axis.

Annex 1

Category HS6 Sheet HS6/3

10/ Dimensions j, k and p are measured from the centre of the passing beam filament to the centre of the driving beam filament. 11/ Dimensions m and n are measured from the reference axis to the centre of the passing beam filament. 12/ Both filaments axis are to be held within a 2 tilt with respect to the reference axis about the centre of the respective filament. 13/ Note concerning the filament diameters: for the same manufacturer, the design filament diameter of standard (étalon) filament lamp and filament lamp of normal production shall be the same. 14/ For both the driving beam and the passing beam filament distortion shall not exceed 5 per cent of filament diameter from a cylinder. 15/ The metal free zone limits the location of lead wires within the optical path. No metal parts shall be located in the shaded area as seen in Figure 6.

Category HS6 Sheet HS6/4

Tolerance

Filaments lamps of normal Standard filament lamp Dimensions in mm production

d1 13/, 17/ 1.4 max. - - 13/, 17/ d2 1.4 max. - - 16/ e 29.45 0.20 0.10 f1 16/ 4.4 0.50 0.25 16/ f2 4.4 0.50 0.25 8/, 17/ g 0.5 d1 0.50 0.30 8/ h 0 0.40 0.20 j 10/ 2.5 0.30 0.20 10/ k 2.0 0.20 0.10 11/ m 0 0.24 0.20 11/ n 0 0.24 0.20 p 10/ 0 0.30 0.20  42° min. - -  52° min. - -  43° +0° / -5° +0° / -5°  9/ 41° 4° 4° Cap PX26.4t in accordance with IEC Publication 60061 (sheet 7004-128-3)

Electrical and photometric characteristics 18/

Rated Volts 12 12 values Watts 40 35 40 35 Test voltage Volts 13.2 13.2

Objective Watts 45 max. 40 max. 45 max. 40 max. values Luminous flux 900  15 % 600  15 % 12 V 630/420 Reference luminous flux at approximately 13.2 V 900/600 16/ The ends of the filament are defined as the points where, when the viewing direction is direction A as shown on sheet HS6/1, the projection of the outside of the end turns crosses the filament axis. 17/ d1 is the actual diameter of the passing beam filament. d2 is the actual diameter of the driving beam filament. 18/ The values indicated in the left-hand columns relate to the driving beam filament and those in the right-hand columns to the passing beam filament.

Annex 1

Categories P13W and PW13W Sheet P13W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.0 mm. 3/ No opaque parts other than filament turns shall be located in the shaded area indicated in Figure 2. This applies to the rotational body within the angles 1 + 2.

Categories P13W and PW13W Sheet P13W/2

Dimensions in mm Filament lamps of normal production Standard filament lamp 5/ 4/ e P13W 25.0 25.0  0.25 PW13W 19.25 4/ 19.25  0.25 5/ 4/ f 4.3 4.3  0.25 6/ 1 30.0° min. 30.0° min. 2 6/ 58.0° min. 58.0° min. P13W Cap PG18.5d-1 in accordance with IEC Publication 60061 (sheet 7004-147-1) PW13W Cap WP3.3x14.5-7 in accordance with IEC Publication 60061 (sheet 7004-164-1)

Electrical and photometric characteristics

Rated Voltage V 12 12 values Wattage W 13 13 Test voltage V 13.5 13.5 Wattage W 19 max. 19 max. Objective Luminous lm 250 values flux  +15% / –20% Reference luminous flux at approximately 13.5V 250 lm 4/ To be checked by means of a "Box-System"; sheet P13W/3. 5/ The ends of the filament are defined as the points where, when the viewing direction is perpendicular to the plane through the filament lead-in wires, the projection of the outside of the end turns crosses the filament axis. 6/ No part of the cap beyond the reference plane shall interfere with angle 2 as shown in These requirements apply to the whole bulb circumference.

Annex 1

Categories P13W and PW13W Sheet P13W/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

p q u1,u2 r,s t,v

Filament lamps of normal production 1.7 1.9 0.3 2.6 0.9

Standard filament lamps 1.5 1.7 0.25 2.45 0.6

The filament position is checked in two mutually perpendicular planes, one of them being the plane through the lead-in wires. The ends of the filament as defined on sheet P13W/2, footnote 4/, shall lie between Z1 and Z2 and between the lines Z3 and Z4. The filament shall lie entirely within the limits shown.

Sheet P19W/1 Categories P19W, PY19W, PR19W, PS19W, PSY19W, PSR19W, PW19W, PWY19W and PWR19W

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ The light emitted from normal production lamps shall be white for categories P19W, PS19W and PW19W; amber for categories PY19W, PSY19W and PWY19W; red for categories PR19W, PSR19W and PWR19W (see also footnote 8/).

Annex 1

Sheet P19W/2 Categories P19W, PY19W, PR19W, PS19W, PSY19W, PSR19W, PW19W, PWY19W and PWR19W

Filament lamps of normal production Standard filament lamp 4/ 8/ Dimensions in mm min. nom. max. e 5/, 6/ P19W, PS19W, PY19W, PSY19W, 24.0 24.0 PR19W, PSR19W PW19W, PWY19W, 18.1 18.1 PWR19W f 5/, 6/ 4.0 4.0  0.2 7/  58° 58° min. P19W Cap PGU20-1 PY19W Cap PGU20-2 PR19W Cap PGU20-5 in accordance with IEC Publication 60061 (sheet 7004-127-2) PS19W Cap PG20-1 PSY19W Cap PG20-2 PSR19W Cap PG20-5 PW19W Cap WP3.3x14.5-1 PWY19W Cap WP3.3x14.5-2 in accordance with IEC Publication 60061 (sheet 7004-164-1) PWR19W Cap WP3.3x14.5-5 Electrical and photometric characteristics

Rated values Volts 12 12 Watts 19 19 Test voltage Volts 13.5 13.5 Watts 20 max. 20 max. P19W 350  15 % PS19W PW19W Objective values Luminous PY19W PSY19W 215  20 % flux PWY19W PR19W PSR19W 80  20 % PWR19W White: 350 lm Reference luminous flux at approximately 13.5 V Amber: 215 lm Red: 80 lm 4/ For categories PS19W, PSY19W and PSR19W, dimensions may be checked with O-ring removed to assure the correct mounting during testing. 5/ The filament position is checked by means of a "Box-System"; sheet P19W/3. 6/ The ends of the filament are defined as the points where, when the viewing direction is perpendicular to the plane through the filament lead-in wires as showed in the drawing on sheet P19W/1, the projection of the outside of the end turns crosses the filament axis. 7/ No part of the cap beyond the reference plane shall interfere with angle . The bulb shall be optically distortion free within the angle 2 + 180°. 8/ The light emitted from standard filament lamps shall be white for categories P19W, PS19W and PW19W; white or amber for categories PY19W, PSY19W and PWY19W; white or red for categories PR19W, PSR19W and PWR19W.

Sheet P19W/3 Categories P19W, PY19W, PR19W, PS19W, PSY19W, PSR19W, PW19W, PWY19W and PWR19W

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

P19W, PY19W, PR19W, PS19W, PSY19W, PSR19W a1 a2 b1, b2 c1 c2

Filament lamps of normal 2.9 3.9 0.5 5.2 3.8 production Standard filament lamps 1.5 1.7 0.25 4.7 3.8

PW19W, PWY19W and PWR19W a1 a2 b1, b2 c1 c2

Filament lamps of normal 2.5 2.5 0.4 5.2 3.8 production Standard filament lamps 1.5 1.7 0.25 4.7 3.8

The filament position is checked in two mutually perpendicular planes, one of them being the plane through the lead-in wires. The ends of the filament as defined on sheet P19W/2, footnote 6/, shall lie between Z1 and Z2 and between the lines Z3 and Z4. The filament shall lie entirely within the limits shown.

Annex 1

Category P21W Sheet P21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max. 3/ 6, 12 V 31.8 31.8  0.3 e 24 V 30.8 31.8 32.8 12 V 5.5 6.0 7.0 6.0  0.5 f 6V 7.0 3/ Lateral 6, 12 V 0.3 max. deviation 1/ 24 V 1.5  75° 90° 105° 90°  5° Cap BA15s in accordance with IEC Publication 60061 (sheet 7004-11A-9) 2/ Electrical and photometric characteristics

Rated Volts 6 12 24 12 values Watts 21 21 Test voltage Volts 6.75 13.5 28.0 13.5

Objective Watts 27.6 max. 26.5 max. 29.7 max. 26.5 max. values Luminous flux 460  15 % Reference luminous flux: 460 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the pins. 2/ Filament lamps with cap BA15d may be used for special purposes; they have the same dimensions. 3/ To be checked by means of a "Box-System"; sheet P21W/2. 4/ In this view the filament of the 24 V type may be straight or V-shaped. This shall be indicated in the application of approval. If it is straight, the screen projection requirements, sheet P21W/2, apply. If it is V-shaped, the filament ends shall be at the same distance within ±3 mm from the reference plane.

Category P21W Sheet P21W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within 15°, to the plane through the centre line of the pins (P21W) or of the reference pin (PY21W and PR21W) and the reference axis, whether a filament lamp complies with the requirements. Side elevation Front elevation

Reference a b h k

Dimension 3.5 3.0 9.0 1.0

Test procedures and requirements

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Annex 1

Category P21/4W Sheet P21/4W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. 1/ e 31.8 31.8  0.3 f 7.0 7.0 + 0 /- 2 1/ Lateral deviation 0.3 max. 2/ 1/ x,y 2.8  0.5 1/ 1/ 1/  75° 90° 105° 90°  5° Cap BAZ15d in accordance with IEC Publication 60061 (sheet 7004-11C-3) Electrical and photometric characteristics

Rated Volts 12 24 12 values Watts 21 4 21 4 21/4 Test Volts 13.5 28.0 13.5 voltage Watts 26.5 max. 5.5 max. 29.7 max. 8.8 max. 26.5/5.5 max. Objective Luminous flux 440 15 440 20 values % 15 20 15 20

Reference luminous flux: 440 lm and 15 lm at approximately 13.5 V 1/ These dimensions shall be checked by means of a "Box-System"3 based on the dimensions and tolerances shown above. "x" and "y" refer to the major (high-wattage) filament, not to the reference axis. Means of increasing the positioning accuracy of the filament and of the cap-holder assembly are under consideration. 2/ Maximum lateral deviation of the major filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 3/ The "Box-System" is the same as for filament lamp P21/5W.

Category P21/5W Sheet P21/5W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Standard filament Filament lamps of normal production lamp Dimensions in mm min. nom. max. 1/ e 6, 12 V 31.8 31.8  0.3 24 V 30.8 31.8 32.8 f 6, 12 V 7.0 7.0 + 0 /- 2 1/ 6, 12 V 0.3 max. Lateral deviation 2/ 24 V 1.5 1/ x, y 6, 12 V 2.8  0.3 3/ x 24 V -1.0 0 1.0 3/ y 24 V 1.8 2.8 3.8  75° 90° 105° 90°  5° Cap BAY15d in accordance with IEC Publication 60061 (sheet 7004-11B-7) Electrical and photometric characteristics

Rated Volts 6 12 24 12 values Watts 21 5 21 5 21 5 21/5 Test voltage Volts 6.75 13.5 28.0 13.5 Watts 27.6 max. 6.6 max. 26.5 max. 6.6 max. 29.7 max. 11.0 max. 26.5 and 6.6 max. Luminous 440 35 440 35 440 40 Objective flux values % 15 20 15 20 15 20

Reference luminous flux: 440 and 35 lm at approximately 13.5 V

For the notes see sheet P21/5W/2

Annex 1

Category P21/5W Sheet P21/5W/2 1/ These dimensions shall be checked by means of a "box-system". See sheets P21/5W/2 and P21/5W/3. "x" and "y" refer to the major (high-wattage) filament, not to the reference axis. 2/ Maximum lateral deviation of the major (high wattage) filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 3/ In this view the filaments of the 24 V type may be straight or V-shaped. This shall be indicated in the application of approval. If the filaments are straight, the screen projection requirements apply. If they are V-shaped, the ends of each filament shall be at the same distance within ±3 mm from the reference plane. Screen projection requirements This test is used to determine, by checking whether:
(a) The major (high wattage) filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within ±15°, to the plane through the centres of the pins and the reference axis; and whether
(b) The minor (low wattage) filament is correctly positioned relative to the major (high wattage) filament, whether a filament lamp complies with the requirements. Test procedure and requirements

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. (i.e. 15°). The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical, the reference pin to the right and the major filament seen end-on:

2.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;

2.2.

The projection of the minor filament shall lie entirely:

2.2.1.

Within a rectangle of width "c" and height "d" having its centre at a distance "v" to the right of and at a distance "u" above the theoretical position of the centre of the major filament;

2.2.2.

Above a straight line tangential to the upper edge of the projection of the major filament and rising from left to right at an angle of 25°.

2.2.3.

To the right of the projection of the major filament.

3.Front elevation

The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:

3.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;

3.2.

The centre of the major filament shall not be offset by more than distance "k" from the reference axis.

3.3.

The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps).

Category P21/5W Sheet P21/5W/3

Dimensions in mm

Reference a b c d u v

Dimensions 3.5 3.0 4.8 2.8

Reference a h k

Dimensions 3.5 9.0 1.0

Annex 1

Sheet P24W/1 Categories P24W, PX24W, PY24W, PR24W, PS24W, PSX24W, PSY24W, PSR24W, PW24W, PWY24W and PWR24W

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ The light emitted from normal production lamps shall be white for categories P24W, PX24W, PS24W, PSX24W and PW24W; amber for categories PY24W, PSY24W and PWY24W; red for categories PR24W, PSR24W and PWR24W (see also footnote 8/).

Sheet P24W/2 Categories P24W, PX24W, PY24W, PR24W, PS24W, PSX24W, PSY24W, PSR24W, PW24W, PWY24W and PWR24W

Filament lamps of normal production Standard filament lamp Dimensions in mm 4/ min. nom. max. 8/

e 5/, 6/ P24W, PY24W, PR24W, PS24W, 24.0 24.0 PSY24W, PSR24W, PX24W, PSX24W PW24W, PWY24W, PWR24W 18.1 18.1 f 5/, 6/ P24W, PY24W, PR24W, PS24W, PSY24W, 4.0 4.0 PSR24W, PW24W, PWY24W, PWR24W PX24W, PSX24W 4.2 4.2 7/  58.0 ° 58.0° min. P24W Cap PGU20-3 PX24W Cap PGU20-7 PY24W Cap PGU20-4 PR24W Cap PGU20-6 PS24W Cap PG20-3 in accordance with IEC Publication 60061 (sheet 7004-127-2) PSX24W Cap PG20-7 PSY24W Cap PG20-4 PSR24W Cap PG20-6 PW24W Cap WP3.3x14.5-3 PWY24W Cap WP3.3x14.5-4 in accordance with IEC Publication 60061 (sheet 7004-164-1) PWR24W Cap WP3.3x14.5-6 Electrical and photometric characteristics

Rated values Volts 12 12 Watts 24 24 Test voltage Volts 13.5 13.5 Watts 25 max. 25 max. P24W 500 +10/-20 % PS24W PW24W PX24W 500 +10/-15 % Objective values Luminous PSX24W flux PY24W 300 +15/-25 % PSY24W PWY24W PR24W 115 +15/-25 % PSR24W PWR24W 12 V White: 345 lm

13.2 V White: 465 lm Reference luminous flux at approximately White: 500 lm 13.5 V Amber: 300 lm Red: 115 lm 4/ For categories PS24W, PSX24W, PSY24W and PSR24W, dimensions may be checked with O-ring removed to assure the correct mounting during testing. 5/ The filament position is checked by means of a "box-system"; sheet P24W/3. 6/ The ends of the filament are defined as the points where, when the viewing direction is perpendicular to the plane through the filament lead- in wires as showed in the drawing on sheet P24W/1, the projection of the outside of the end turns crosses the filament axis. 7/ No part of the cap beyond the reference plane shall interfere with angle . The bulb shall be optically distortion free within the angle 2 + 180°. 8/ The light emitted from standard filament lamps shall be white for categories P24W, PX24W, PS24W, PSX24W and PW24W; white or amber for categories PY24W, PSY24W and PWY24W; white or red for categories PR24W, PSR24W and PWR24W.

Annex 1

Sheet P24W/3 Categories P24W, PX24W, PY24W, PR24W, PS24W, PSX24W, PSY24W, PSR24W, PW24W, PWY24W and PWR24W

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

P24W, PY24W, PR24W, PS24W, PSY24W, PSR24W a1 a2 b1, b2 c1 c2

Filament lamps of normal production 2.9 3.9 0.5 5.2 3.8 Standard filament lamps 1.5 1.7 0.25 4.7 3.8

PW24W, PWY24W, PWR24W a1 a2 b1, b2 c1 c2

Filament lamps of normal production 2.5 2.5 0.4 5.0 3.8 Standard filament lamps 1.5 1.7 0.25 4.7 3.8

PX24W, PSX24W a1 a2 b1, b2 c1 c2

Filament lamps of normal production 1.9 1.9 0.35 5.0 4.0 Standard filament lamps 1.5 1.5 0.25 4.7 4.0

The filament position is checked in two mutually perpendicular planes, one of them being the plane through the lead-in wires. The ends of the filament as defined on sheet P24W/2, footnote 6/, shall lie between Z1 and Z2 and between the lines Z3 and Z4. The filament shall lie entirely within the limits shown.

Category P27W Sheet P27W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 27.9 3/ 27.9  0.3 f 9.9 9.9 + 0 / - 2 Lateral deviation 2/ 3/ 0.0  0.4  75°3/ 90° 105°3/ 90°  5° Cap W2.5x16d in accordance with IEC Publication 60061 (sheet 7004-104-1)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 27 27 Test voltage Volts 13.5 13.5 Watts 32.1 max. 32.1 max. Objective values Luminous 475  15 % flux Reference luminous flux: 475 lm at approximately 13.5 V 1/ The reference axis is defined with respect to the reference keys and is perpendicular to the reference plane. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis through the reference keys. 3/ To be checked by means of a "Box System", sheet P27W/2.

Annex 1

Category P27W Sheet P27W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within 15°, to the plane through the centres of the keys and the reference axis, whether a filament lamp complies with the requirements.

Reference a b h k

Dimension 3.5 3.0 11.9 1.0

Test procedures and requirements.

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Category P27/7W Sheet P27/7W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max. 3/ e 27.9 27.9  0.3 f 9.9 9.9 + 0 / -2 2/ 3/ Lateral deviation 0.0  0.4 x 4/ 5.1 3/ 5.1  0.5 y 4/ 0.0 3/ 0.0  0.5  75°3/ 90° 105°3/ 90°  5° Cap W2.5x16q in accordance with IEC Publication 60061 (sheet 7004-104-1) Electrical and photometric characteristics Volts 12 12 Rated values Watts 27 7 27 7 Test voltage Volts 13.5 13.5 Watts 32.1 max. 8.5 max. 32.1 max. 8.5 max. Objective values Luminous 475  15 % 36  15 % flux Reference luminous flux: 475 and 36 lm at approximately 13.5 V 1/ The reference axis is defined with respect to the reference keys and is perpendicular to the reference plane. 2/ Maximum lateral deviation of the major (high wattage) filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis through the reference keys. 3/ To be checked by means of a "Box-System", sheets P27/7W/2 and 3. 4/ "x" and 'y" denote the offset of the axis of the minor (low wattage) filament with respect to the axis of the major (high wattage) filament.

Annex 1

Category P27/7W Sheet P27/7W/2

Screen projection requirements This test is used to determine, by checking whether:
(a) The major (high wattage) filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within ±15°, to the plane through the centres of the keys and the reference axis; and whether:
(b) The minor (low wattage) filament is correctly positioned relative to the major (high wattage) filament, whether a filament lamp complies with the requirements. Test procedure and requirements.

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical, the reference key to the right and the major filament seen end-on:

2.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;

2.2.

The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.

3.Front elevation

The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:

3.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;

3.2.

The centre of the major filament shall not be offset by more than distance "k" from the reference axis;

3.3.

The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps).

Category P27/7W Sheet P27/7W/3

Reference a b c d u

Dimension 3.5 3.0 4.8 5.1

Reference a h k

Dimension 3.5 11.9 1.0

Annex 1

Sheet PC16W/1 Categories PC16W, PCY16W, PCR16W, PW16W, PWY16W and PWR16W

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ The light emitted from normal production lamps shall be white for category PC16W and PW16W; amber for category PCY16W and PWY16W; red for category PCR16W and PWR16W. (see also footnote 7/).

Sheet PC16W/2 Categories PC16W, PCY16W, PCR16W, PW16W, PWY16W and PWR16W

Filament lamps of normal production Standard filament lamp 7/ Dimensions in mm min. nom. max.

PC16W PCY16W 18.5 18.5 e 4/, 5/ PCR16W PW16W PWY16W 17.1 17.1 PWR16W f 4/, 5/ 4.0 4.0  0.2 α 6/ 54° 54° min. PC16W Cap PU20d-1 PCY16W Cap PU20d-2 in accordance with IEC Publication 60061 (sheet 7004-157-1) PCR16W Cap PU20d-7 PW16W Cap WP3.3x14.5-8 PWY16W Cap WP3.3x14.5-9 in accordance with IEC Publication 60061 (sheet 7004-164-1) PWR16W Cap WP3.3x14.5-10 Electrical and photometric characteristics

Volts 12 12 Rated values Watts 16 16 Test voltage Volts 13.5 13.5 Watts 17 max. 17 max. PC16W 300  15 % PW16W Objective values Luminous PCY16W 180  20 % flux PWY16W PCR16W 70  20 % PWR16W White: 300 lm Reference luminous flux at approximately 13.5 V Amber: 180 lm Red: 70 lm 4/ The filament position is checked by means of a "Box-System"; sheet PC16W/3. 5/ The ends of the filament are defined as the points where, when the viewing direction is perpendicular to the plane through the filament lead-in wires as showed in the drawing on sheet PC16W/1, the projection of the outside of the end turns crosses the filament axis. 6/ No part of the cap beyond the reference plane shall interfere with angle . The bulb shall be optically distortion free within the angle 2 + 180°. 7/ The light emitted from standard filament lamps shall be white for category PC16W and PW16W; white or amber for category PCY16W and PWY16W; white or red for category PCR16W and PWR16W.

Annex 1

Sheet PC16W/3 Categories PC16W, PCY16W, PCR16W, PW16W, PWY16W and PWR16W

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

PC16W, PCY16W, PCR16W a1 a2 b1, b2 c1 c2

Filament lamps of normal 2.9 3.9 0.5 5.2 3.8 production Standard filament lamps 1.5 1.7 0.25 4.7 3.8

PW16W, PWY16W and PWR16W a1 a2 b1, b2 c1 c2

Filament lamps of normal 2.5 2.5 0.4 5.2 3.8 production Standard filament lamps 1.5 1.7 0.25 4.7 3.8

The filament position is checked in two mutually perpendicular planes, one of them being the plane through the lead-in wires. The ends of the filament as defined on sheet PC16W/2, footnote 5/, shall lie between Z1 and Z2 and between the lines Z3 and Z4. The filament shall lie entirely within the limits shown.

Category PR21W Sheet PR21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp 4/ Dimensions in mm min. nom. max.

12 V 31.8 3/ 31.8  0.3 e 24 V 30.8 31.8 32.8

f 12 V 5.5 6.0 7.0 6.0  0.5 3/ Lateral 12 V 0.3 max deviation 1/ 24 V 1.5  75° 90° 105° 90°  5° Cap BAW15s in accordance with IEC Publication 60061 (sheet 7004-11E-1)

Electrical and photometric characteristics

Volts 12 24 12 Rated values: Watts 21 21 Test voltage: Volts 13.5 28.0

Objective Watts 26.5 max. 29.7 max. 26.5 max. values: Luminous flux: 110  20 % White: 460 lm Reference luminous flux at approximately 13.5 V: Red: 110 lm 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 2/ The light emitted from normal production lamps shall be red (see also footnote 4/). 3/ To be checked by means of a "Box-System", sheet P21W/2. 4/ The light emitted from standard filament lamps shall be white or red. 5/ In this view the filament of the 24 V type may be straight or V-shaped. This shall be indicated in the application of approval. If it is straight, the screen projection requirements, sheet P21W/2, apply. If it is V-shaped, the filament ends shall be at the same distance within 3 mm from the reference plane.

Annex 1

Category PR21/4W Sheet PR21/4W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production 5/ Standard filament lamp 6/ Dimensions in mm min. nom. max.

e 31.8 1/ 31.8  0.3 f 7.0 7.0 + 0 / -2 1/ Lateral deviation 0.3 max.2/ 1/ x,y 2.8  0.5 1/ 1/  75° 90° 105°1/ 90°  5° Cap BAU15d in accordance with IEC Publication 60061 (sheet 7004-19-2) Electrical and photometric characteristics

Rated Volts 12 24 4/ 12 values Watts 21 4 21 4 21/4 Test voltage Volts 13.5 28.0 13.5 Watts 26.5 max. 5.5 max. 29.7 max. 8.8 max. 26.5/5.5 max. Objective Luminous 105 4 105 5 values flux % 20 25 20 25 White: 440 lm and 15 lm Reference luminous flux at approximately 13.5 V: Red: 105 lm and 4 lm 1/ These dimensions shall be checked by means of a "Box-System"3 based on the dimensions and tolerances shown above. "x" and "y" refer to the major (high-wattage) filament, not to the reference axis. Means of increasing the positioning accuracy of the filament and of the cap-holder assembly are under consideration. 2/ Maximum lateral deviation of the major filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 3/ The "Box-System" is the same as for filament lamp P21/5W. 4/ The 24-Volt filament lamp is not recommended for future embodiments. 5/ The light emitted from normal production lamps shall be red (see also footnote 6/). 6/ The light emitted from standard filament lamps shall be white or red.

Category PR21/5W Sheet PR21/5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production4/ Standard filament lamp 5/ Dimensions in mm min. nom. max.

e 12 V 31.8 1/ 31.8  0.3 24 V 30.8 31.8 32.8 f 12 V 7.0 7.0 + 0 / -2 1/ Lateral deviation 2/ 12 V 0.3 max. 24 V 1.5 1/ x, y 12 V 2.8  0.3 x 24 V 3/ -1.0 0 1.0 y 24 V 3/ 1.8 2.8 3.8  75° 90° 105° 90°  5° Cap BAW15d in accordance with IEC Publication 60061 (sheet 7004-11E-1)

Electrical and photometric characteristics

Volts 12 24 12 Rated values Watts 21 5 21 5 21/5 Test voltage Volts 13.5 28.0 13.5 Watts 26.5 max. 6.6 max. 29.7 max. 11.0 max. 26.5 and 6.6 max. Objective values Luminous flux 105 8 105 10 +%  % 20 25 20 25 White: 440 lm and 35 lm Reference luminous flux at approximately 13.5 V: Red: 105 lm and 8 lm 1/ See footnote 1/ on sheet P21/5W/2. 2/ See footnote 2/ on sheet P21/5W/2. 3/ See footnote 3/ on sheet P21/5W/2. 4/ The light emitted from normal production lamps shall be red (see also footnote 5/). 5/ The light emitted from standard filament lamps shall be white or red.

Annex 1

Category PR27/7W Sheet PR27/7W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp 6/ Dimensions in mm min. nom. max.

e 27.9 3/ 27.9  0.3 f 9.9 9.9 + 0 / -2 Lateral deviation2/ 3/ 0.0  0.4 x 4/ 5.1 3/ 5.1  0.5 4/ y 0.0 3/ 0.0  0.5  75°3/ 90° 105°3/ 90°  5° Cap WU2.5x16 in accordance with IEC Publication 60061 (sheet 7004-104D-1) Electrical and photometric characteristics

Rated values Volts 12 12 Watts 27 7 27 7 Test voltage Volts 13.5 13.5 Objective Watts 32.1 max. 8.5 max. 32.1 max. 8.5 max. values Luminous flux 110  20 % 9  20 % White: 475 and 36 lm Reference luminous flux at approximately 13.5 V: Red : 110 and 9 lm 1/ The reference axis is defined with respect to the reference keys and is perpendicular to the reference plane. 2/ Maximum lateral deviation of the major (high wattage) filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis through the reference keys. 3/ To be checked by means of a "Box-System", sheets P27/7W/2 and 3. 4/ "x" and 'y" denote the offset of the axis of the minor (low wattage) filament with respect to the axis of the major (high wattage) filament. 5/ The light emitted from normal production lamps shall be red (see also footnote 6/). 6/ The light emitted from standard filament lamps shall be white or red.

Category PSX26W Sheet PSX26W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ No opaque parts other than filament turns shall be located in the shaded area indicated in

Annex 1

Category PSX26W Sheet PSX26W/2

Filament lamps of normal Dimensions in mm production Standard filament lamp

e 5/ 24.0 4/ 24.0  0.25

f 5/ 4.2 4/ 4.2  0.25

1 6/ 35.0° min. 35.0° min.

2 6/ 58.0° min. 58.0° min.

Cap PG18.5d-3 in accordance with IEC Publication 60061 (sheet 7004-147-1)

Electrical and photometric characteristics

Voltage V 12 12 Rated values Wattage W 26 26

Test voltage V 13.5 13.5

Wattage W 26 max. 26 max. Objective lm 500 values Luminous flux  +10% / -10%

Reference luminous flux at approximately 12 V 345 lm

Reference luminous flux at approximately 13.2 V 465 lm

Reference luminous flux at approximately 13.5 V 500 lm

4/ To be checked by means of a "Box-System"; sheet PSX26W/3. 5/ The ends of the filament are defined as the points where, when the viewing direction is perpendicular to the plane through the filament lead-in wires, the projection of the outside of the end turns crosses the filament axis. 6/ No part of the cap beyond the reference plane shall interfere with angle 2 as shown in Figure 1 on sheet PSX26W/1. The bulb shall be optically distortion free within the angles 1+ 2. These requirements apply to the whole bulb circumference.

Category PSX26W Sheet PSX26W/3

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane, whether a filament lamp complies with the requirements.

a1 a2 b1,b2 c1 c2

Filament lamps of normal 1.7 1.7 0.30 5.0 4.0 production

Standard filament lamps 1.5 1.5 0.25 4.7 4.0

The filament position is checked in two mutually perpendicular planes, one of them being the plane through the lead-in wires. The ends of the filament as defined on sheet PSX26W/2, footnote 4/, shall lie between Z1 and Z2 and between the lines Z3 and Z4. The filament shall lie entirely within the limits shown.

Annex 1

Category PY21W Sheet PY21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp 4/ Dimensions in mm min. nom. max.

e 12 V 31.8 3/ 31.8  0.3 24 V 30.8 31.8 32.8 f 12 V 7.0 7.0 +0 / -2 Lateral deviation 1/ 12 V 3/ 0.3 max. 24 V 1.5  75° 90° 105° 90°  5° Cap BAU15s in accordance with IEC Publication 60061 (sheet 7004-19-2) Electrical and photometric characteristics

Rated values Volts 12 24 12 Watts 21 21 Test voltage Volts 13.5 28.0 13.5 Objective Watts 26.5 max. 29.7 max. 26.5 max. values Luminous flux 280  20 % White: 460 lm Reference luminous flux at approximately 13.5 V: Amber: 280 lm

1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 2/ The light emitted from production lamps shall be amber (see also footnote 4/). 3/ To be checked by means of a "Box-System"; sheet P21W/2. 4/ The light emitted from standard filament lamps shall be amber or white. 5/ In this view the filament of the 24 V type may be straight or V-shaped. This shall be indicated in the application of approval. If it is straight, the screen projection requirements, sheet P21W/2, apply. If it is V-shaped, the filament ends shall be at the same distance within ±3 mm from the reference plane.

Category PY27/7W Sheet PY27/7W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp 6/ Dimensions in mm min. nom. max.

e 27.9 3/ 27.9  0.3 f 9.9 9.9 + 0 / -2 2/ 3/ Lateral deviation 0.0  0.4 4/ 3/ x 5.1 5.1  0.5 4/ 3/ y 0.0 0.0  0.5 3/ 3/  75° 90° 105° 90°  5° Cap WX2.5x16q in accordance with IEC Publication 60061 (sheet 7004-104A-1) Electrical and photometric characteristics

Rated values Volts 12 12 Watts 27 7 27 7 Test voltage Volts 13.5 13.5 Objective Watts 32.1 max. 8.5 max. 32.1 max. 8.5 max. values Luminous flux 280  15 % 21  15 % Reference luminous flux at approximately 13.5 V: White: 475 and 36 lm Amber: 280 and 21 lm 1/ The reference axis is defined with respect to the reference keys and is perpendicular to the reference plane. 2/ Maximum lateral deviation of the major (high wattage) filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis through the reference keys. 3/ To be checked by means of a "Box-System", sheets P27/7W/2 and 3. 4/ "x" and 'y" denote the offset of the axis of the minor (low wattage) filament with respect to the axis of the major (high wattage) filament. 5/ The light emitted from filament lamps of normal production shall be amber (see also footnote 6). 6/ The light emitted from standard filament lamps shall be amber or white.

Annex 1

Category R2 Sheet R2/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Electrical and photometric characteristics

Filament lamps of normal production Standard filament lamp

Volts 6 4/ 12 4/ 24 4/ 12 4/ Rated values Watts 45 40 45 40 55 50 45 40

Test Volts 6.3 13.2 28.0 13.2 voltage Watts 53 max. 47 max. 57 max. 51 max. 76 max. 69 max. 52 46 +0 % 5 % Objective -10 % values Luminous 720 min. 570 860 min. 675 1,000 min. 860 flux 15% 15% 15% Measuring flux 5/ - 450 - 450 - 450

Reference luminous flux at approximately 12V 700 450

1/ The reference axis is perpendicular to the reference plane and passes through the centre of the 45 mm cap diameter. 2/ The colour of the light emitted shall be white or selective-yellow. 3/ No part of the cap shall, by reflection of light emitted by the passing beam filament, throw any stray rising ray when the filament lamp is in the normal operating position on the vehicle. 4/ The values indicated on the left and on the right refer to the driving beam filament and the passing beam filament respectively. 5/ Measuring luminous flux for measurements according to paragraph 3.9. of this Regulation.

Category R2 Sheet R2/2

Position and dimensions (in mm) of shield and filaments The drawings are not mandatory with respect to the design of the shield and filaments

Annex 1

Category R2 Sheet R2/3

Filaments and shield position and dimensions 1/

Tolerance

Filament lamps of normal production Standard filament lamp

Dimensions in mm 6V 12V 24V 12V

a 0.60 0.35 0.15 b1/30.0 2/ 0.20 0.35 0.15 b1/33.0 b1/30.0 mv 3/ b2/30.0 2/ 0.20 0.35 0.15 b2/33.0 b2/30.0 mv 3/ c/30.0 2/ 0.50 0.30 0.15 c/33.0 c/30.0 mv 3/ 6, 12 V 28.5 e 0.35 0.15 24 V 28.8 6, 12 V 1.8 f 0.40 0.20 24 V 2.2 g 0 0.50 0.30 h/30.0 2/ 0 0.50 0.30 h/33.0 h/30.0 mv 3/ 1/2(p-q) 0 0.60 0.30 IC 5.5 1.50 0.50 4/  15 nom. Cap P45t-41 in accordance with IEC Publication 60061 (sheet 7004-95-5) 1/ The position and dimensions of the shield and filaments shall be checked by means of the method of measurement as described in IEC Publication 60809. 2/ To be measured at the distance from the reference plane indicated in millimetres behind the stroke. 3/ mv = measured value. 4/ The angle  is only for shield design and has not to be checked on finished filament lamps.

Category R5W and RR5W Sheet R5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm 4/ min. nom. max. e 17.5 19.0 20.5 19.0  0.3 2/ Lateral deviation 1.5 0.3 max.  60° 90° 120° 90°  5° R5W: BA15s (sheet 7004-11A-9) 1/ Cap: in accordance with IEC Publication 60061 RR5W: BAW15s (sheet 7004-11E-1)

Electrical and photometric characteristics

Volts 65/ 12 24 12 Rated values Watts 5 5 Test voltage Volts 6.75 13.5 28.0 13.5 Watts 5.5 max. 7.7 max. 5.5 max. Objective values Luminous R5W 50  20 % flux RR5W 5/ 12  25 % White: 50 lm Reference luminous flux at approximately 13.5 V: Red: 12 lm 1/ Filament lamps with cap BA15d may be used for special purposes; they have the same dimensions. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 3/ The light emitted from filament lamps of normal production shall be white for category R5W and red for category RR5W (see also footnote 4/). 4/ The light emitted from standard filament lamps shall be white for category R5W; white or red for category RR5W. 5/ Within RR5W no 6 V rated voltage type specified.

Annex 1

Categories R10W, RY10W and RR10W Sheet R10W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp.

Filament lamps of normal production Standard filament lamp 4/ Dimensions in mm min. nom. max.

e 17.5 19.0 20.5 19.0  0.3 Lateral deviation 2/ 1.5 0.3 max.  60° 90° 120° 90°  5° R10W: BA15s (sheet 7004-11A-9) 1/ Cap RY10W: BAU15s in accordance with IEC Publication 60061 (sheet 7004-19-2) RR10W: BAW15s (sheet 7004-11E-1)

Electrical and photometric characteristics

Volts 6 5/ 12 24 12 Rated values Watts 10 10 Test voltage Volts 6.75 13.5 28 13.5 R10W 11 max. 11 max. Watts RY10W 14 max. 5/ Objective RR10W 11 max. 11 max. values Luminous R10W 125  20 % flux RY10W 75  20 % 5/ RR10W 30  25 % White: 125 lm Reference luminous flux at approximately 13.5 V: Amber: 75 lm Red: 30 lm 1/ Filament lamps R10W with cap BA15d may be used for special purposes; they have the same dimensions. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of the reference pin. 3/ The light emitted from filament lamps of normal production shall be white for category R10W, amber for category RY10W and red for category RR10W (see also footnote 4/) 4/ The light emitted from standard filament lamps shall be white for category R10W; white or amber for category RY10W; white or red for category RR10W. 5/ Within RR10W no 6 V rated voltage type specified.

Categories S1 and S2 Sheet S1/S2/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp. Filament lamps for motorcycles

1/ The colour of the light emitted shall be white or selective-yellow. 2/ The reference plane is perpendicular to the reference axis and touches the upper surface of the lug having a width of 4.5 mm. 3/ Plane V-V contains the reference axis and the centre line of the lugs. 4/ Plane H-H (the normal position of the shield) is perpendicular to plane V-V and contains the reference axis.

Annex 1

Categories S1 and S2 Sheet S1/S2/2

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 32.35 32.70 33.05 32.7  0.15 f 1.4 1.8 2.2 1.8  0.2 l 4.0 5.5 7.0 5.5  0.5 5/ c 0.2 0.5 0.8 0.5  0.15 5/ b -0.15 0.2 0.55 0.2  0.15 5/ a 0.25 0.6 0.95 0.6  0.15 h -0.5 0 0.5 0  0.2 g -0.5 0 0.5 0  0.2 5/, 6/  -2°30' 0° +2°30' 0°  1° Cap BA20d in accordance with IEC Publication 60061 (sheet 7004-12-7)

Electrical and photometric characteristics

S1 6 Volts 6 7/ 12 7/ Rated S2 12 values S1 25 25 25 25 25 25 Watts S2 35 35 35 35 35 35 Test S1 6.75 13.5 6.75 Volts voltage S2 6.3 13.5 13.5 S1 25  5% 25  5% 25  5% 25  5% 25  5% 25  5% Watts Objective S2 35  5% 35  5% 35  5% 35  5% 35  5% 35  5% values Luminous S1 435  20% 315  20% 435 20 % 315  20% flux S2 650  20% 465  20% 650  20% 465  20% S1 at approximately 6V 398 284 Reference luminous 12 V 568 426 flux S2 at approximately 13.2 V 634 457 13.5 V 650 465

5/ Dimensions a, b, c and  refer to a plane parallel to the reference plane and cutting the two edges of the shield at a distance of e + 1.5 mm. 6/ Admissible angular deviation of the shield plane position from the normal position. 7/ Values in the left-hand column refer to the driving beam filament. Values in the right-hand column to the passing beam filament.

Category S3 Sheet S3/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamp for mopeds

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 2/ 19.0 19.5 20.0 19.5  0.25 6V 3.0 2.5  0.5 f 12 V 4.0 h1, h2 3/ -0.5 0 0.5 0  0.3 Cap P26s in accordance with IEC Publication 60061 (sheet 7004-36-1)

Electrical and photometric characteristics

Volts 6 12 6 Rated values Watts 15 15 Test voltage Volts 6.75 13.5 6.75 Watts 15  6% 15  6% Objective values Luminous 240  15% flux Reference luminous flux: 240 lm at approximately 6.75 V

1/ The colour of the light emitted shall be white or selective-yellow. 2/ Distance related to the luminous centre. 3/ Lateral deviation of filament axis with respect to the reference axis. It is sufficient to check this deviation in two mutually perpendicular planes.

Annex 1

Category T1.4W Sheet T1.4W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp.

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 7.6 8.3 9.0 8.3  0.35 Lateral deviation 1/ 0.7 0.35 max  55° 70° 85° 70°  5° Cap P11.5d in accordance with IEC Publication 60061 (sheet 7004-79-1)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 1.4 1.4 Test voltage Volts 13.5 13.5 Watts 1.54 max. 1.54 max. Objective values Luminous 8  15 % flux Reference luminous flux: 8 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the circle of diameter "M".

Category T4W Sheet T4W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp.

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 13.5 15.0 16.5 15.0  0.3 Lateral deviation 1/ 1.5 0.5 max  90° 90°  5° Cap BA9s in accordance with IEC Publication 60061 (sheet 7004-14-9)

Electrical and photometric characteristics

Volts 6 12 24 12 Rated values Watts 4 4 Test voltage Volts 6.75 13.5 28.0 13.5 Watts 4.4 max. 5.5 max. 4.4 max. Objective values Luminous 35  20 % flux Reference luminous flux: 35 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis of pins. 2/ Over the entire length of the cap there shall be no projections or soldering extending beyond the permissible maximum diameter of the cap.

Annex 1

Category W2.3W Sheet W2.3W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 10.3 10.8 11.3 10.8  0.3 1/ Lateral deviation 1.0 0.5 max  -15° 0° +15° 0°  5° Cap W2x4.6d in accordance with IEC Publication 60061 (sheet 7004-94-2)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 2.3 2.3 Test voltage Volts 13.5 13.5 Watts 2.5 max. 2.5 max. Objective values Luminous 18.6  20 % flux Reference luminous flux: 18.6 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X.

Category W3W Sheet W3W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 11.2 12.7.0 14.2 12.7  0.3 1/ Lateral deviation 1.5 0.5 max  -15° 0° +15° 0°  5° Cap W2.1x9.5d in accordance with IEC Publication 60061 (sheet 7004-91-3)

Electrical and photometric characteristics

Volts 6 12 24 12 Rated values Watts 3 3 Test voltage Volts 6.75 13.5 28.0 13.5 Watts 3.45 max. 4.6 max. 3.45 max. Objective values Luminous 22  30 % flux Reference luminous flux: 22 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X.

Annex 1

Category W5W, WY5W and WR5W Sheet W5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp 3/ Dimensions in mm min. nom. max.

e 11.2 12.7 14.2 12.7  0.3 1/ Lateral deviation 1.5 0.5 max.  -15° 0° +15° 0°  5° Cap W2.1x9.5d in accordance with IEC Publication 60061 (sheet 7004-91-3) Electrical and photometric characteristics

Volts 6 4/ 12 24 12 Rated values Watts 5 5 Test voltage Volts 6.75 13.5 28.0 13.5 Watts 5.5 max. 7.7 max. 5.5 max.

Objective W5W 50  20 % values Luminous WY5W 30  20 % flux 4/ WR5W 12  25 % White: 50 lm Reference luminous flux at approximately 13.5 V: Amber: 30 lm Red: 12 lm 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 2/ The light emitted from filament lamps of normal production shall be white for category W5W, amber for category WY5W and red for category WR5W (see also footnote 3.) 3/ The light emitted from standard filament lamps shall be white for category W5W; white or amber for category WY5W; white or red for category WR5W. 4/ Within WR5W no 6 V rated voltage type specified.

Categories W10W and WY10W Sheet W10W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 15.5 17.0 18.5 17.0  0.3 Lateral deviation 1/ 1.0 0.5 max.  -15° 0° +15° 0°  5° Cap W2.1x9.5d in accordance with IEC Publication 60061 (sheet 7004-91-3)

Electrical and photometric characteristics

Rated Volts 6 12 12 values Watts 10 10 Test voltage Volts 6.75 13.5 13.5

Watts 11 max. 11 max. Objective values Luminous White 125  20 % flux Amber 75  20 %

White: 125 lm Reference luminous flux at approximately 13.5 V: Amber: 75 lm

1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X.

Annex 1

Category W15/5W Sheet W15/5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamp for motorcycles a = major (high wattage) filament b = minor (low wattage) filament

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 25.0 1/ 25.0  0.3 f 7.5 7.5 + 0 / -2 Lateral deviation 2/ 1/ 0.3 max. 3/ 1/ x 2.8 2.8  0.3 3/ 1/ y 0.0 0.0  0.3 1/ 1/  -15° 0° +15° 0°  5° Cap WZ3x16q in accordance with IEC Publication 60061 (sheet 7004-151-1) Electrical and photometric characteristics Volts 12 12 Rated values Watts 15 5 15 5 Test voltage Volts 13.5 13.5

Objective Watts 19.1 max. 6.6 max. 19.1 max. 6.6 max. values Luminous flux 280  15 % 35  20 % Reference luminous flux: 280 lm and 35 lm at approximately 13.5 V 1/ To be checked by means of a "Box-System"; sheets W15/5W/2 and 3. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 3/ "x" and "y" denote the offset of the axis of the minor filament with respect to the axis of the major filament.

Category W15/5W Sheet W15/5W/2

Screen projection requirements This test is used to determine, by checking whether:
(a) The major filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within ±15°, to the plane through the axis X-X and the reference axis; and whether:
(b) The minor filament is correctly positioned relative to the major filament, whether a filament lamp complies with the requirements. Test procedure and requirements.

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits. (±15°).

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the major filament seen end-on:

2.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;

2.2.

The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.

3.Front elevation

The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:

3.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;

3.2.

The centre of the major filament shall not be offset by more than distance "k" from the reference axis.

3.3.

The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps).

Annex 1

Category W15/5W Sheet W15/5W/3

Reference a b c d u

Dimensions 3.3 2.8 4.8 2.8

Reference a h k

Dimensions 3.3 9.5 1.0

Categories W16W AND WY16W Sheet W16W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 18.3 20.6 22.9 20.6  0.3 Lateral deviation 1/ 1.0 0.5 max.  -15° 0° +15° 0°  5° Cap W2.1x9.5d in accordance with IEC Publication 60061 (sheet 7004-91-3)

Electrical and photometric characteristics

Rated Volts 12 12 values Watts 16 16 Test Volts 13.5 13.5 voltage Watts 21.35 max. 21.35 max. Objective values Luminous White 310  20 % flux Amber 190  20 %

White: 310 lm Reference luminous flux at approximately 13.5 V: Amber: 190 lm

1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X

Annex 1

Category W21W Sheet W21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 29.0 2/ 29.0  0.3 f 7.5 7.5 + 0 / -2 Lateral deviation 1/ 2/ 0.5 max. 2/ 2/  -15° 0° +15° 0°  5° Cap W3x16d in accordance with IEC Publication 60061 (sheet 7004-105-2) Electrical and photometric characteristics

Volts 12 12 Rated values Watts 21 21 Test voltage Volts 13.5 13.5 Watts 26.5 max. 26.5 max. Objective values Luminous 460  15 % flux Reference luminous flux: 460 lm at approximately 13.5 V 1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 2/ To be checked by means of a "Box-System"; see sheet W21W/2.

Category W21W Sheet W21W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within  15°, to the plane through the axis X-X and the reference axis, whether a filament lamp complies with the requirements. Side elevation Front elevation

Reference a b h k

Dimension 3.5 3.0 9.5 1.0

Test procedures and requirements

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits, i.e. 15°. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits (15°).

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament;

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Annex 1

Category W21/5W Sheet W21/5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp a = major (high wattage) filament b = minor (low wattage) filament

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 25.0 1/ 25.0  0.3 f 7.5 7.5 + 0 / -2 2/ 1/ Lateral deviation 0.3 max. x 3/ 2.8 1/ 2.8  0.3 y 3/ 0.0 1/ 0.0  0.3  -15° 1/ 0° +15° 1/ 0°  5° Cap W3x16q in accordance with IEC Publication 60061 (sheet 7004-106-3) Electrical and photometric characteristics Volts 12 12 Rated values Watts 21 5 21 5 Test voltage Volts 13.5 13.5

Objective Watts 26.5 max. 6.6 max. 26.5 max. 6.6 max. values Luminous flux 440  15 % 35  20 % Reference luminous flux: 440 and 35 lm at approximately 13.5 V 1/ To be checked by means of a "Box-System"; sheets W21/5W/2 and 3. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 3/ "x" and "y" denote the offset of the axis of the minor filament with respect to the axis of the major filament.

Category W21/5W Sheet W21/5W/2

Screen projection requirements This test is used to determine, by checking whether:
(a) The major filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within ±15°, to the plane through the axis X-X and the reference axis; and whether:
(b) The minor filament is correctly positioned relative to the major filament, whether a filament lamp complies with the requirements. Test procedure and requirements.

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits (±15°).

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the major filament seen end-on:

2.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;

2.2.

The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.

3.Front elevation

The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:

3.1.

The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;

3.2.

The centre of the major filament shall not be offset by more than distance "k" from the reference axis;

3.3.

The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps).

Annex 1

Category W21/5W Sheet W21/5W/3

Reference a b c d u

Dimension 3.5 3.0 4.8 2.8

Reference a h k

Dimension 3.5 9.5 1.0

Categories WP21W and WPY21W Sheet WP21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 27.9 3/ 27.9  0.3 f 5.5 6.0 7.0 6.0  0.5 2/ 3/ Lateral deviation 0.0  0.4 3/ 3/  75° 90° 105° 90°  5° WP21W: WY2.5x16d (sheet 7004-104B-1) Cap: in accordance with IEC Publication 60061 WPY21W: WZ2.5x16d (sheet 7004-104C-1)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 21 21 Test voltage Volts 13.5 13.5 Watts 26.5 max. 26.5 max. Objective values Luminous WP21W 460  15% flux WPY21W 280  20% White: 460 lm Reference luminous flux at approximately 13.5 V Amber: 280 lm

1/ The reference axis is defined with respect to the reference keys and is perpendicular to the reference plane. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing the axis through the reference keys. 3/ To be checked by means of a "Box-System"; sheet WP21W/2. 4/ The light emitted from filament lamps of normal production shall be white for category WP21W and amber for category WPY21W (see also footnote 5/) 5/ The light emitted from standard filament lamps shall be white for category WP21W and white or amber for category WPY21W.

Annex 1

Categories WP21W and WPY21W Sheet WP21W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within 15°, to the plane through the centre line of the keys and the reference axis, whether a filament lamp complies with the requirements. Side elevation Front elevation

Reference a b h k

Dimension 3.5 3.0 9.0 1.0

Test procedures and requirements

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Category WR21/5W Sheet WR21/5W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp a = major (high wattage) filament b = minor (low wattage) filament

Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. 1/ e 25.0 25.0  0.3 f 7.5 7.5 + 0 / -2 2/ 1/ Lateral deviation 0.3 max. 3/ 1/ x 2.8 2.8  0.3 y 3/ 0.0 1/ 0.0  0.3 1/ 1/  -15° 0° 15° 0°  5° Cap WY3x16q in accordance with IEC Publication 60061 (sheet 7004-106-3) Electrical and photometric characteristics Rated Volts 12 12 values Watts 21 5 21 5 Test voltage Volts 13.5 13.5 Objective Watts 26.5 max. 6.6 max. 26.5 max. 6.6 max. values Luminous flux 105  20 % 8  25 %

Reference luminous flux at approximately 13.5 V White: 440 lm and 35 lm Red: 105 lm and 8 lm 1/ To be checked by means of a "Box-System"; sheets W21/5W/2 and 3. 2/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 3/ "x" and "y" denote the offset of the axis of the minor filament with respect to the axis of the major filament. 4/ The light emitted from normal production lamps shall be red (see also footnote 5/). 5/ The light emitted from standard filament lamps shall be white or red.

Annex 1

Category WY2.3W Sheet WY2.3W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max.

e 10.3 10.8 11.3 10.8  0.3 Lateral deviation 1/ 1.0 0.5 max  -15° 0° +15° 0°  5° Cap W2x4.6d in accordance with IEC Publication 60061 (sheet 7004-94-2)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 2.3 2.3 Test voltage Volts 13.5 13.5 Watts 2.5 max. 2.5 max. Objective values Luminous 11.2  20 % flux

White: 18.6 lm Reference luminous flux at approximately 13.5 V Amber: 11.2 lm

1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 2/ The light emitted from production lamps shall be amber (see also footnote 3/). 3/ The light emitted from standard filament lamps shall be amber or white.

Category WY21W Sheet WY21W/1

The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp.

Filament lamps of normal production Standard filament lamp

Dimensions in mm min. nom. max. 2/ e 29.0 29.0  0.3 f 7.5 7.5 + 0 / -2 Lateral deviation 1/ 2/ 0.5 max.  -15° 0° +15° 0°  5° Cap WX3x16d in accordance with IEC Publication 60061 (sheet 7004-105-2)

Electrical and photometric characteristics

Volts 12 12 Rated values Watts 21 21 Test voltage Volts 13.5 13.5 Watts 26.5 max. 26.5 max. Objective values Luminous 280  20 % flux

White: 460 lm Reference luminous flux at approximately 13.5 V: Amber: 280 lm

1/ Maximum lateral deviation of filament centre from two mutually perpendicular planes both containing the reference axis and one containing axis X-X. 2/ The light emitted from filament lamps of normal production shall be amber (see also footnote 4/). 3/ To be checked by means of a "Box-System"; sheet WY21W/2. 4/ The light emitted from standard filament lamps shall be amber or white.

Annex 1

Category WY21W Sheet WY21W/2

Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and reference plane and has an axis perpendicular, within 15°, to the plane through the axis X-X and the reference axis, whether a filament lamp complies with the requirements. Side elevation Front elevation

Reference a b h k

Dimension 3.5 3.0 9.5 1.0

Test procedures and requirements

1.

The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits, i.e. 15°. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits (15°).

2.Side elevation

The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.

3.Front elevation

The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:

3.1.

The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.

3.2.

The centre of the filament shall not be offset by more than distance "k" from the reference axis.

Annex 2 — Communication

(Maximum format: A4 (210 x 297 mm))

issued by: Name of administration

concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued

of a type of filament lamp pursuant to Regulation No. 37

Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). Strike out what does not apply.

Annex 2

Colour of the light emitted: White/selective-yellow/amber/red2 Colour coating on glass bulb: yes/no2 Halogen filament lamp: yes/no2

12.

Approval granted/refused/extended/withdrawn2:

16.

The following documents, bearing the approval mark shown above, are

Annex 3 — Example of the arrangement of the approval mark

(see paragraph 2.4.3.)

The above approval mark affixed to a filament lamp indicates that the lamp has been approved in the United Kingdom (E11) under the approval code A1. The first character of the approval code indicates that the approval was granted in accordance with the requirements of Regulation No. 37 as amended by the 02 and 03* series of amendments.

* Not requiring changes in the approval number.

Annex 4

Annex 4 — Luminous centre and shapes of filament lamps

Save as possibly otherwise stated on the filament lamp data sheets, this standard is applicable to the determination of the luminous centre of different filament shapes. The position of the luminous centre depends upon the filament shape.

No. Filament shapes Observations

With b > 1.5 h, the deviation of the filament axis with respect to a plane normal to the reference axis shall not exceed 15°

Only applicable to filaments which can be inscribed in a rectangle of b > 3h.

Applicable to filaments which can be inscribed in a rectangle of b  3h, h/3

whereby, however, k < 2h. h k

b/2 b

The side lines of the circumscribed rectangles in Nos. 2 and 3 are parallel and perpendicular, respectively, to the reference axis. The luminous centre is the intersection of the dash-dot lines. The drawings are intended only to demonstrate the essential dimensions.

Annex 5 — Checking the colour of filament lamps

1.General

1.1.

Measurements shall be made on finished lamps. Filament lamps with secondary (outer) bulb acting as colour filter shall be handled as filament lamp with primary bulb.

1.2.

Tests shall be made at an ambient temperature of 23 °C ± 5 °C.

1.3.

Tests shall be made at test voltage(s) as specified in the relevant lamp data sheet.

1.4.

Filament lamps shall be measured preferably in the normal operating position. In case of dual filament lamps the high wattage (major or driving
beam) filament shall be operated only.

1.5.

Before starting a test, the stabilisation of the temperature of the filament lamp shall be obtained by operating at test voltage for 10 minutes. In the case of filament lamps, for which more than one test voltage is specified, the relevant test voltage value shall be used for achieving stabilization.

2.Colour

2.1.

Colour tests shall be made with a measuring system that determines CIE trichromatic co-ordinates of the received light with an accuracy of ±0.002.

2.2.

The trichromatic coordinates shall be measured with a colourimetric receiver integrating over a right circular cone subtending an angle of minimum 5° and maximum 15°, at the centre of the filament.

2.3.

Measuring directions (see the figure below).

2.3.1.

Initially, the receiver shall be positioned perpendicular to the lamp axis and to the filament axis (or plane in case of a curved filament). After measurement the receiver shall be moved around the filament lamp in bi-directional steps of about 30° until the area specified in paragraphs 2.3.2. or 2.3.3. is covered. In each position a measurement shall be made. However, no measurement shall be made when:
(a) The centreline of the receiver coincides with the filament axis; or
(b) The line of sight between the receiver and the filament is blocked by opaque (non-transmitting) parts of the light source, such as lead wires or a second filament, if any.

2.3.2.

For filament lamps used in headlamps, measurements shall be made in directions around the filament lamp with the centreline of the receiver aperture located within an angle ±30°, from the plane perpendicular to the lamp axis with the origin in the centre of the filament. In case of filament lamps with two filaments, the centre of the driving beam filament shall be taken.

Annex 5

2.3.3.

For filament lamps used in light signalling devices, measurements shall be made in directions around the filament lamp with exception of:
(a) The area claimed or covered by the cap of the filament lamp; and
(b) The immediate transition area along the cap. In case of filament lamps with two filaments, the centre of the major filament shall be taken.

Figure illustrating the positions of colourimetric receiver

Annex 6

Minimum requirements for quality control procedures by the manufacturer

1.General

The conformity requirements shall be considered satisfied from a photometric, geometrical, visual and electrical standpoint if the specified tolerances for production filament lamps in the relevant data sheet of Annex 1 and the relevant data sheet for the caps are met.

2.Minimum requirements for verification of conformity by the manufacturer

For each type of filament lamp the manufacturer or the holder of the approval mark shall carry out tests, in accordance with the provisions of this Regulation, at appropriate intervals.

2.1.

Nature of tests

Tests of conformity of these specifications shall cover their photometric, geometrical and optical characteristics.

2.2.

Methods used in tests

2.2.1.

Tests shall generally be carried out in accordance with the methods set out in this Regulation.

2.2.2.

The application of paragraph 2.2.1. requires regular calibration of test apparatus and its correlation with measurements made by a competent authority.

2.3.

Nature of sampling

Samples of filament lamps shall be selected at random from the production of a uniform batch. A uniform batch means a set of filament lamps of the same type, defined according to the production methods of the manufacturer.

2.4.

Inspected and recorded characteristics

The filament lamps shall be inspected and test results recorded following the grouping of characteristics as listed in Annex 7, Table 1.

2.5.

Criteria governing acceptability

The manufacturer or the holder of approval is responsible for carrying out a statistical study of the test results in order to meet the specifications laid down for verification of conformity of production in paragraph 4.1. of this Regulation. Compliance shall be assured if the level of acceptable non-compliance per grouping of characteristics given in Table 1 of Annex 7 is not exceeded. This means that the number of filament lamps not complying with the requirement for any grouping of characteristics of any filament lamp type does not exceed the qualifying limits in the relevant Tables 2, 3 or 4 of Annex 7. Note: Each individual filament lamp requirement shall be considered as a characteristic.

Annex 7

Annex 7 — Sampling and compliance levels for manufacturer test

records

Table 1

Characteristics

Acceptable level of non-
                              Grouping*of test records   Minimum 12 monthly     compliance per grouping
Grouping of characteristics   between lamp types         sample per grouping*   of characteristics (%)

Marking, legibility           All types with the                315                        1
and durability                same external
dimensions

Bulb quality                  All types with the                315                        1
same bulb

All types
(emitting red and
 Colour of the bulb           amber light) of the                20                        1
same category and
colour technology

External lamp                 All types of the                  200                        1
dimensions (excluding         same category
cap/base)

Dimensions of caps            All types of the                  200                       6.5
and bases                     same category

Dimensions related to         All lamps of one                  200                       6.5
internal elements**           type

Initial readings, watts       All lamps of one                  200                        1
and lumens**                  type

Colour endurance test         All lamps (emitting              20***                       1
red, amber and
white light) of one
colour coating
technology
 *     The assessment shall in general cover series production filament lamps from individual
factories. A manufacturer may group together records concerning the same type from several
factories, provided these operate under the same quality system and quality management.
** In case a filament lamp has more than one inner element (filament, shield) the grouping of
characteristics (dimensions, watts, lumens) applies to each element separately.
*** Representative distribution over categories of lamps using the same colour coating technology
and finishing, and that comprises lamps of the smallest and the largest diameter of the outer bulb,
each at the highest rated wattage.

Qualifying limits for acceptance based on different numbers of test results for each
grouping of characteristics are listed in Table 2 as maximum number of non-compliance.
The limits are based on an acceptable level of 1 per cent of non-compliance, assuming an
acceptance probability of at least 0.95.
Table 2

*

Number of test results of each characteristics       Qualifying limits for acceptance

 20                                                                  0
 21 - 50                                                             1
 51 - 80                                                             2
 81 - 125                                                            3
 126 - 200                                                           5
 201 - 260                                                           6
 261 - 315                                                           7
 316 - 370                                                           8
 371 - 435                                                           9
 436 - 500                                                          10
 501 - 570                                                          11
 571 - 645                                                          12
 646 - 720                                                          13
 721 - 800                                                          14
 801 - 860                                                          15
 861 - 920                                                          16
 921 - 990                                                          17
 991 - 1,060                                                        18
 1,061 - 1,125                                                      19
 1,126 - 1,190                                                      20
 1,191 - 1,249                                                      21

*       In accordance with ISO 2859-1:1999 "Sampling procedures for inspection by
attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-
lot inspection" including Technical Corrigendum 1:2001.

Annex 7

Qualifying limits for acceptance based on different numbers of test results for each
grouping of characteristics are listed in Table 3 given as maximum number of non-
compliance. The limits are based on an acceptable level of 6.5 per cent of non-compliance,
assuming an acceptance probability of at least 0.95.
Table 3
Number of                         Number of                      Number of
lamps in          Qualifying       lamps in     Qualifying        lamps in    Qualifying
records                 limit       records           limit        records          limit

    - 200                 21     541 - 553              47        894 - 907           73
201 - 213                 22     554 - 567              48        908 - 920           74
214 - 227                 23     568 - 580              49        921 - 934           75
228 - 240                 24     581 - 594              50        935 - 948           76
241 - 254                 25     595 - 608              51        949 - 961           77
255 - 268                 26     609 - 621              52        962 - 975           78
269 - 281                 27     622 - 635              53        976 - 988           79
282 - 295                 28     636 - 648              54      989 - 1,002           80
296 - 308                 29     649 - 662              55     1,003 -,1016           81
309 - 322                 30     663 - 676              56    1,017 - 1,029           82
323 - 336                 31     677 - 689              57    1,030 - 1,043           83
337 - 349                 32     690 - 703              58    1,044 - 1,056           84
350 - 363                 33     704 - 716              59    1,057 - 1,070           85
364 - 376                 34     717 - 730              60    1,071 - 1,084           86
377 - 390                 35     731 - 744              61    1,085 - 1,097           87
391 - 404                 36     745 - 757              62    1,098 - 1,111           88
405 - 417                 37     758 - 771              63    1,112 - 1,124           89
418 - 431                 38     772 - 784              64    1,125 - 1,138           90
432 - 444                 39     785 - 798              65    1,139 - 1,152           91
445 - 458                 40     799 - 812              66    1,153 - 1,165           92
459 - 472                 41     813 - 825              67    1,166 - 1,179           93
473 - 485                 42     826 - 839              68    1,180 - 1,192           94
486 - 499                 43     840 - 852              69    1,193 - 1,206           95
500 - 512                 44     853 - 866              70    1,207 - 1,220           96
513 - 526                 45     867 - 880              71    1,221 - 1,233           97
527 - 540                 46     881 - 893              72    1,234 - 1,249           98

Qualifying limits for acceptance based on different numbers of test results for each
grouping of characteristics are listed in Table 4 given as a percentage of the results,
assuming an acceptance probability of at least 0.95.
Table 4
Qualifying limits shown as a     Qualifying limits shown as a
                                    percentage of results.           percentage of results.
Number of test results of each   Acceptable level of 1% of non-   Acceptable level of 6.5% of non-
characteristic                           compliance                        compliance

1,250                                        1.68                              7.91
2,000                                        1.52                              7.61
4,000                                        1.37                              7.29
6,000                                        1.30                              7.15
8,000                                        1.26                              7.06
10,000                                       1.23                              7.00
20,000                                       1.16                              6.85
40,000                                       1.12                              6.75
80,000                                       1.09                              6.68
100,000                                      1.08                              6.65
1,000,000                                    1.02                              6.55

Annex 8

Annex 8 — Minimum requirements for spot checks by the Type

Approval Authority

1.General

The conformity requirements shall be considered satisfied from a photometric, geometrical, visual and electrical standpoint if the specified tolerances for production filament lamps in the relevant data sheet of Annex 1 and the relevant data sheet for the caps are met.

2.

The conformity of mass-produced filament lamps shall not be contested if the results are in agreement with Annex 9 to this Regulation.

3.

Conformity shall be contested and the manufacturer requested to make the production meet the requirements if the results are not in agreement with Annex 9 to this Regulation.

4.

If paragraph 3 of this annex is applied, a further sample of 250 filament lamps, selected at random from a recent production run, shall be taken within two months.

Annex 9 — Compliance approved by spot check

Compliance approved or disapproved shall be decided according to the values in Table 1. For each grouping of characteristics filament lamps shall be either accepted or rejected according to the values in Table 1*.

Table 1

1 %** 6.5 %**

Accept           Reject       Accept             Reject

First sample size: 125                         2               5           11                 16
If the number of non-conforming                6               7           26                 27
units is greater than 2 (11) and less
than 5 (16) take a second sample
size of 125 and assess the 250
 *      The proposed scheme is designed to assess the compliance of filament lamps to an acceptance
level of non-compliance of 1 per cent and 6.5 per cent respectively and is based on the Double
Sampling Plan for Normal Inspection in IEC Publication 60410: Sampling Plans and Procedures for
Inspection by Attributes.
** The filament lamps shall be inspected and test results recorded following the grouping of
characteristics as listed in Annex 7, Table 1.