1.Scope
This Regulation applies to gas-discharge light sources shown in Annex 1 to this Regulation and intended for use in approved gas-discharge lamp units of power-driven vehicles.
2.Administrative provisions
Definitions
The term "category" is used in this Regulation to describe different basic design of standardized gas-discharge light sources. Each category has a specific designation, as for example: "D2S".
"Gas-discharge light sources of different types"1 are gas-discharge light sources within the same category which differ in such essential respects as:
Trade name or mark; that means:
(a) Gas-discharge light sources bearing the same trade name or mark but produced by different manufacturers are considered as being of different types.
(b) Gas-discharge light sources produced by the same manufacturer differing only by the trade name or mark may be considered to be of the same type;
Bulb and/or cap design, in so far as these differences affect the optical results.
Application for approval
Application for approval shall be submitted by the owner of the trade name or mark, or by his duly accredited representative.
Every application for approval shall be accompanied (see also paragraph 2.4.2. below) by:
Drawings in triplicate, sufficiently detailed to permit identification of the type;
A technical description including, if the ballast is not integrated with the light source, ballast identification;
Three samples of each colour which has been applied for;
One sample of the ballast in case the ballast is not integrated with the light source.
In the case of a type of gas-discharge light source differing only by the trade name or mark from a type that has already been approved it shall be sufficient to submit:
A selective yellow bulb or an additional selective yellow outer bulb, solely intended to change the colour but not the other characteristics of a gas-discharge light source emitting white light, does not constitute a change of type of the gas-discharge light source.
A declaration by the manufacturer that the type submitted is identical (except in the trade name or mark) to and has been produced by the same manufacturer as, the type already approved, the latter being identified by its approval code;
Two samples bearing the new trade name or mark.
The Type Approval Authority shall verify the existence of satisfactory arrangements for ensuring effective control of the conformity of production before type approval is granted.
Inscriptions
Gas-discharge light sources submitted for approval shall bear on the cap or bulb:
The trade name or mark of the applicant;
The international designation of the relevant category;
The rated wattage; this need not to be indicated separately if it is part of the international designation of the relevant category;
A space of sufficient size to accommodate the approval mark.
The space mentioned in paragraph 2.3.1.4. above shall be indicated in the drawings accompanying the application for approval.
Other inscriptions than those covered by paragraphs 2.3.1. above and 2.4.4. below may be affixed on the cap.
In case the ballast is not integrated with the light source, the ballast used for the type approval of the light source shall be marked with type and trade mark identification and with the rated voltage and wattage, as indicated on the relevant lamp data sheet.
Approval
If all samples of a type of gas-discharge light source which are submitted in accordance with paragraphs 2.2.2.3. or 2.2.3.2. above comply with the requirements of this Regulation, when tested with the ballast according to paragraph 2.2.2.4. in case the ballast is not integrated with the light source, approval shall be granted.
An approval code shall be assigned to each type approved. Its first character shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. This will be followed by an identification code comprising not more than three characters. Only the Arabic numerals and capital letters listed in footnote2 shall be used. The same Contracting Party may not assign the same code to another type of gas-discharge light source. If the applicant so desires the same approval code
0123456789 ABCDEFGHJKLMNPRSTUVWXYZ
may be assigned to both gas-discharge light sources emitting white and selective yellow light (see paragraph 2.1.2. above).
Notice of approval or of extension or refusal or withdrawal of approval or production definitively discontinued of a type of gas-discharge light source pursuant to this Regulation shall be communicated to the Parties of the Agreement which apply this Regulation by means of a form conforming to the model in Annex 2 to this Regulation and of a drawing, supplied by the applicant for approval in a format not exceeding A4 (210 x 297 mm) and on a scale of at least 2 : 1.
To every gas-discharge light source conforming to a type approved under this Regulation there shall be affixed in the space referred to in paragraph 2.3.1.4. above, in addition to the inscriptions required under paragraph 2.3.1. above, an international approval mark consisting of:
A truncated circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval;3
The approval code, placed close to the truncated circle.
If the applicant has obtained the same approval code for several trade names or marks, one or more of them will suffice to meet the requirements of paragraph 2.3.1.1 above.
The marks and inscriptions specified in paragraphs 2.3.1. and 2.4.3. above shall be clearly legible and be indelible.
Annex 3 to this Regulation gives an example of arrangement of the approval mark.
3.Technical requirements
Definitions
"Gas-discharge light source": light source in which the light is produced by a stabilized discharge arc.
"Ballast": Specific electrical supply for the gas-discharge light source, optionally integrated with the light source.
"Rated voltage": Input voltage marked on the ballast or on the light source in the case that the ballast is integrated with the light source.
"Rated wattage": Wattage marked on the gas-discharge light source and ballast.
"Test voltage": Voltage, at the input terminals of the ballast or at the terminals of the light source in the case that the ballast is integrated with the light source, for which the electrical and photometric characteristics of the gas-discharge light source are intended and are to be tested.
The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev. 3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
"Objective value": Design value of an electrical or photometric characteristic. To be achieved, within the specified tolerances, when the gas-discharge light source is energized by the ballast, optionally integrated with the light source, and operated at test voltage.
"Standard (etalon) gas-discharge light source": Special gas-discharge light source used for the testing of headlamps. It has reduced dimensional, electrical and photometric characteristics as specified on the relevant data sheet.
"Reference axis": An axis defined with reference to the cap and to which certain dimensions of the gas-discharge light source are referred.
"Reference plane": a plane defined with reference to the cap and to which certain dimensions of the gas-discharge light source are referred.
General specifications
Each sample submitted shall conform to the relevant specifications of this Regulation when tested, in the case the ballast is not integrated with the light source with the ballast according to paragraph 2.2.2.4 above.
Gas-discharge light sources shall be so designed as to be and to remain in good working order when in normal use. They shall moreover exhibit no fault in design or manufacture.
Manufacture
The bulb of the gas-discharge light source shall exhibit no scores or spots which might impair their efficiency and their optical performance.
In the case of a coloured (outer) bulb, after an operating period of 15 hours with the ballast or the light source with the ballast integrated at test voltage, the surface of the bulb shall be lightly wiped with a cotton cloth soaked in a mixture of 70 volume per cent of n-heptane and 30 volume per cent of toluol. After about five minutes, the surface shall be inspected visually. It shall not show any apparent changes.
Gas-discharge light sources shall be equipped with standard caps complying with the cap data sheets of IEC Publication 60061, third edition, as specified on the individual data sheets of Annex 1 to this Regulation.
The cap shall be strong and firmly secured to the bulb.
To ascertain whether gas-discharge light sources conform to the requirements of paragraphs 3.3.3. to 3.3.4. above, a visual inspection, a dimension check and, where appropriate, a trial fitting shall be carried out.
Tests
Gas-discharge light sources shall be aged as indicated in Annex 4 to this Regulation.
All samples shall be tested with the ballast, according to paragraph 2.2.2.4. above, in case the ballast is not integrated with the light source.
Electrical measurements shall be carried out with instruments of at least class
(0.2 per cent full scale accuracy).
Position and dimensions of electrodes, arc and stripes
The geometric position of the electrodes shall be as specified on the relevant data sheet. An example of a method of measuring arc and electrodes position is given in Annex 5 to this Regulation. Other methods may be used.
The position and dimensions of the light source electrodes shall be measured before the ageing period, the gas-discharge light source unlit and using optical methods through the glass envelope.
The shape and the displacement of the arc shall conform to the requirements as given on the relevant data sheet.
The measurement shall be made after ageing with the light source supplied by the ballast at test voltage or the light source with the ballast integrated at test voltage.
The position and dimension and transmission of the stripes shall comply with the requirements as given on the relevant data sheet.
The measurement shall be made after ageing with the light source supplied by the ballast at test voltage or the light source with the ballast integrated at test voltage.
Starting, run-up and hot-restrike characteristics
Starting
When tested according to the conditions specified in Annex 4 to this Regulation, the gas-discharge light source shall start directly and remain alight.
Run-up
For gas-discharge light sources having an objective luminous flux which exceeds 2000 lm: When measured according to the conditions specified in Annex 4 to this Regulation, the gas-discharge light source shall emit at least: After 1 second: 25 per cent of its objective luminous flux; After 4 seconds: 80 per cent of its objective luminous flux. The objective luminous flux as indicated on the relevant data sheet.
For gas-discharge light sources having an objective luminous flux which does not exceed 2000 lm: When measured according to the conditions specified in Annex 4 to this Regulation, the gas-discharge light sources shall emit at least 800 lm after 1 second and at least 1000 lm after 4 seconds. The objective luminous flux as indicated on the relevant data sheet.
Hot-restrike
When tested according to the conditions specified in Annex 4 to this Regulation, the gas-discharge light source shall restart directly after being switched-off for a period as indicated on the data sheet. After one second the light source shall emit at least 80 per cent of its objective luminous flux.
Electrical characteristics
When measured according to the conditions specified in Annex 4 to this Regulation, the voltage and wattage of the light source shall be within the limits given on the relevant data sheet.
Luminous flux
When measured according to the conditions specified in Annex 4 to this Regulation, the luminous flux shall be within the limits given on the relevant data sheet. In the case where white and selective yellow is specified for the same type, the objective value applies to light sources emitting white light, whereas the luminous flux of the light source emitting selective yellow light shall be at least 68 per cent of the specified value.
Colour
The colour of the light emitted shall be white or selective yellow. Moreover, the colorimetric characteristics, expressed in CIE chromaticity coordinates, shall lie within the boundaries given on the relevant data sheet.
The definitions of the colour of the light emitted, given in Regulation No. 48 and its series of amendments in force at the time of application for type approval shall apply to this Regulation.
The colour shall be measured according to the conditions specified in Annex
4 to this Regulation, paragraph 10.
The minimum red content of a gas-discharge light source shall be such that: 780 nm ∫ Ee(λ).V(λ).dλ λ=610 nm ____________________ kred = ≥ 0.05 780 nm ∫ Ee(λ).V(λ).dλ λ=380 nm Where: Ee (λ) [W/nm] is the spectral distribution of the radiant flux; V (λ) [1] is the spectral luminous efficiency; λ [nm] is the wave length. This value shall be calculated using intervals of one nanometre.
UV radiation
The UV radiation of the gas-discharge light source shall be such that the gas discharge light source is of the low UV type complying with: 400 nm ∫ Ee(λ)·S(λ)·dλ λ=250 nm ____________________ -5 kuv = ≤ 10 W/lm 780 nm km · ∫ Ee(λ)·V(λ)·dλ λ=380 nm
Where: S (λ) [1] is the spectral weighting function; km = 683 [lm/W] is the photometric radiation equivalent; (For definitions of other symbols see paragraph 3.9.5. above). This value shall be calculated using intervals of one nanometre. The UV-radiation shall be weighted according to the values as indicated in the following table.
λ S(λ) λ S(λ) λ S(λ)
250 0.430 305 0.060 355 0.00016 255 0.520 310 0.015 360 0.00013 260 0.650 315 0.003 365 0.00011 265 0.810 320 0.001 370 0.000090 270 1.000 325 0.00050 375 0.000077 275 0.960 330 0.00041 380 0.000064 280 0.880 335 0.00034 385 0.000053 285 0.770 340 0.00028 390 0.000044 290 0.640 345 0.00024 395 0.000036 295 0.540 350 0.00020 400 0.000030 300 0.300
Wavelengths chosen are representative; other values should be interpolated. Values according to "IRPA/INIRC Guidelines on limits of exposure to ultraviolet radiation".
Standard gas-discharge light sources
Standard (etalon) gas-discharge light sources shall comply with the requirements applicable to type approval light sources and to the specific requirements as stated in the relevant data sheet. In case of a type emitting white and selective yellow light, the standard light source shall emit white light.
4.Conformity of production
Gas-discharge light sources approved to this Regulation shall be so manufactured as to conform to the type approved by meeting the inscriptions and technical requirements set forth in paragraph 3. above and Annexes 1 and 3 to this Regulation.
In order to verify that the requirements of paragraph 4.1. are met, suitable controls of the production shall be carried out.
The holder of the approval shall in particular:
Ensure existence of procedures for the effective control of the quality of products,
Have access to the control equipment necessary for checking the conformity to each approved type,
Ensure that data of test results are recorded and that related documents shall remain available for a period to be determined in accordance with the administrative service,
Analyse the results of each type of test, applying criteria of Annex 7 to this Regulation, in order to verify and ensure the stability of the product characteristics making allowance for variation of an industrial production,
Ensure that for each type of gas-discharge light source, at least the tests prescribed in Annex 6 to this Regulation are carried out,
Ensure that any collecting of samples giving evidence of non-conformity with the type of test considered shall give rise to another sampling and another test. All the necessary steps shall be taken to re-establish the conformity of the corresponding production.
The Type Approval Authority which has granted type-approval may at any time verify the conformity control methods applicable to each production unit.
In every inspection, the test books and production survey records shall be presented to the visiting inspector.
The inspector may take samples at random which will be tested in the manufacturer's laboratory. The minimum number of samples may be determined according to the results of the manufacturer's own verification.
When the quality level appears unsatisfactory or when it seems necessary to verify the validity of the tests carried out in application of paragraph 4.4.2. above, the inspector shall select samples, to be sent to the Technical Service which has conducted the type approval tests.
The Type Approval Authority may carry out any tests prescribed in this Regulation. These tests will be on samples selected at random without causing distortion of the manufacturer’s delivery commitments and in accordance with criteria of Annex 8 to this Regulation.
The Type Approval Authority shall strive to obtain a frequency of inspection of once every two years. However, this is at the discretion of the Type Approval Authority and their confidence in the arrangements for ensuring effective control of conformity of production. In the case where negative results are recorded, the Type Approval Authority shall ensure that all necessary steps are taken to re-establish the conformity of production as rapidly as possible.
5.Penalties for non-conformity of production
The approval granted in respect of a gas-discharge light source pursuant to this Regulation may be withdrawn if the prescribed conformity of production requirements are not met.
If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously granted, it shall forthwith so notify the other
Contracting Parties applying this Regulation, by means of a communication form conforming to the model in Annex 2 to this Regulation.
6.Production definitively discontinued
If the holder of the approval completely ceases to manufacture a type of gas- discharge light source approved in accordance with this Regulation, he shall so inform the authority which had granted the approval. Upon receiving the relevant communication, that authority shall inform thereof the other Parties to the Agreement applying this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.
Names and addresses of the Technical Services responsible for conducting approval tests, and of Type Approval Authorities The Contracting Parties to the Agreement which apply this Regulation shall communicate to the United Nations Secretary-General the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, or production definitively discontinued issued in other countries, are to be sent.
Annex 1
Annex 1 — Sheets for gas-discharge light sources
List of categories of gas-discharge light sources and their sheet numbers:
Light source category Sheet numbers
D1R DxR/1 to 7 D1S DxS/1 to 6 D2R DxR/1 to 7 D2S DxS/1 to 6 D3R DxR/1 to 7 D3S DxS/1 to 6 D4R DxR/1 to 7 D4S DxS/1 to 6 D5S D5S/1 to 5 D6S D6S/1 to 5 D8S D8S/1 to 5
List of sheets for gas-discharge light sources and their sequence in this annex:
Sheet numbers
DxR/1 to 7 (Sheet DxR/6: two pages) DxS/1 to 6 D5S/1 to 5 D6S/1 to 5 D8S/1 to 5
Categories D1R, D2R, D3R and D4R Sheet DxR/1
The drawings are intended only to illustrate the essential dimensions (in mm) of the gas-discharge light source
Annex 2 — Communication
(Maximum format: A4 (210 x 297 mm))
issued by: Name of administration:
Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued
of a type of cornering lamp pursuant to Regulation No. 99
(In case the ballast is not integrated with the light source.)
10.Approval granted/refused/extended/withdrawn2
Distinguishing number of the country which has granted/extended/refused/ withdrawn approval (see approval provisions in the Regulation). Strike out what does not apply.
The attached drawing No….. shows the entire light source.
Annex 3
Annex 3 — Example of the arrangement of the approval mark
(see paragraph 2.4.4. of this Regulation)
The above approval mark affixed to a gas-discharge light source indicates that the light source has been approved in the United Kingdom (E 11) under the approval code 0A01. The first character of the approval code indicates that the approval was granted in accordance with the requirements of Regulation No. 99 in its original form.
Annex 4 — Method of measurement of electrical and photometric
characteristics
1.General
For starting, run-up and hot-restrike tests and for the measurement of electrical and photometric characteristics, the gas-discharge light source shall be operated in free air with an ambient temperature of 25° ± 5° C.
2.Ballast
In the case the ballast is not integrated with the light source, all tests and measurements shall be carried out with the ballast as per paragraph 2.2.2.4. of this Regulation. The power supply used for the starting and run-up tests shall be qualified to secure the quick rise of the high current pulse.
3.Burning position
The burning position shall be horizontal within ±10° with the lead wire down. Ageing and testing positions shall be identical. If the lamp is accidentally operated in the wrong direction, it shall be re-aged before measurements begin. During ageing and measurements no electrically conducting objects shall be allowed within a cylinder having a diameter of 32 mm and a length of 60 mm concentric with the reference axis and symmetric to the arc. Moreover stray magnetic fields shall be avoided.
4.Ageing
All tests shall be carried out with light sources which have been aged for a minimum of 15 cycles having the following switching cycle: 45 minutes on, 15 seconds off, 5 minutes on, 10 minutes off.
5.Supply voltage
All tests shall be carried out at test voltage as indicated on the relevant data sheet.
6.Starting test
The starting test shall be applied to light sources which have not been aged and have not been used for a period of at least 24 hours prior to the test.
7.Run-up test
The run-up test shall be applied to light sources which have not been used for a period of at least 1 hour prior to the test.
8.Hot restrike test
The light source shall be started and be operated with the ballast (possibly integrated) at test voltage for a period of 15 minutes. Then the supply voltage to the ballast or the light source with the ballast integrated shall be switched off for a switch-off period as indicated on the relevant data sheet and be switched on again.
Annex 4
9.Electrical and photometric test
Before any measurement, the light source shall be stabilized for a period of 15 minutes.
10.Colour
The colour of the light source shall be measured in an integrating sphere using a measuring system which shows the CIE chromaticity co-ordinates of the received light with a resolution of ± 0.002.The following figure shows the colour tolerance area for colour white and the restricted tolerance area for the gas-discharge light sources D1R, D1S, D2R, D2S, D3R, D3S, D4R, D4S, D5S, D6S and D8S.
Annex 5
Annex 5 — Optical setup for the measurement of the position and form
of the arc and of the position of the electrodes1 The gas-discharge light source shall be positioned as shown: in figure 1 or figure 2 on sheet DxR/1 or sheet DxS/1; in figure 3 or figure 4 on sheet DxR/2 or sheet DxS/2.
An optical system shall project a real image A' of the arc A with a magnification of preferably M = s'/s = 20 on a screen. The optical system shall be aplanatic and achromatic. In the focus-length f of the optical system a diaphragm d shall cause a projection of the arc with nearly parallel observation directions. To get the angle of the half divergence not larger than μ = 0.5°, the diameter of the focus-diaphragm with respect to the focus-length of the optical system shall be not more than d = 2f tan(μ). The active diameter of the optical system shall be not more than: D = (1 + 1/M)d + c + (b1 + b2)/2. (c, b1 and b2 are given on sheet DxS/5, respectively sheet DxR/5). A scale on the screen shall enable to measure the position of the electrodes. The calibration of the arrangement advantageously can be done by using a separate projector with a parallel beam in connection with a gauge whose shadow is projected to the screen. The gauge shall show the reference axis and the plane parallel to the reference plane and at distance "e" mm from it (e = 27.1 for D1R, D1S, D2R, D2S, D3R, D3S, D4R and D4S). In the plane of the screen a receiver has to be mounted movable in a vertical direction on a line corresponding to the plane at "e" from the reference plane of the gas discharge light source. The receiver shall have the relative spectral sensitivity of the human eye. The size of the receiver shall be not more than 0.2 M mm in the horizontal and not more than 0.025 M mm
This method is an example of a measurement method; any method with equivalent measurement accuracy may be used.
in the vertical direction (M = the magnification). The range of measurable movement shall be such that the required measures of the arc bending r and arc diffusion s can be measured.
Annex 6
Annex 6
Minimum requirements for quality control procedures by the manufacturer
1.General
The conformity requirements shall be considered satisfied from a photometric (including UV-radiation), geometrical, visual and electrical standpoint if the specified tolerances for production gas-discharge light sources in the relevant data sheet of Annex 1 to this Regulation and the relevant data sheet for the caps are met.
2.Minimum requirements for verification of conformity by the manufacturer
For each type of gas-discharge light source the manufacturer or the holder of the approval mark shall carry out tests, in accordance with the provisions of this Regulation, at appropriate intervals.
Nature of tests
Tests of conformity of these specifications shall cover their photometric, geometrical and optical characteristics.
Methods used in tests
Tests shall generally be carried out in accordance with the methods set out in this Regulation.
The application of paragraph 2.2.1. of this annex requires regular calibration of test apparatus and its correlation with measurements made by a Type Approval Authority.
Nature of sampling
Samples of gas-discharge light sources shall be selected at random from the production of a uniform batch. A uniform batch means a set of gas-discharge light sources of the same type, defined according to the production methods of the manufacturer.
Inspected and recorded characteristics
The gas-discharge light sources shall be inspected and test results recorded following the grouping of characteristics as listed in Annex 7 to this Regulation, table 1.
Criteria governing acceptability
The manufacturer or the holder of approval is responsible for carrying out a statistical study of the test results in order to meet the specification laid down for verification of conformity of products in paragraph 4.1. of this Regulation. Compliance shall be assured if the level of acceptable non-compliance per grouping of characteristics given in table 1 of Annex 7 to this Regulation is not exceeded. This means that the number of gas-discharge light sources not complying with the requirement for any grouping of characteristics of any
gas-discharge light source type does not exceed the qualifying limits in the relevant tables 2, 3 or 4 of Annex 7 to this Regulation. Note: Each individual gas-discharge light source requirement shall be considered as a characteristic.
Annex 7
Annex 7 — Sampling and compliance levels for manufacturer’s test
records
Characteristics
Grouping* of test Acceptable level of non-
records between gas- compliance per
Grouping of discharge light source Minimum 12 monthly grouping of
characteristics types sample per grouping* characteristics (%)
Marking, legibility All types with the
and durability same external
dimensions 315 1
Bulb quality All types with the
same bulb 315 1
External dimensions All types of the same
(excluding cap) category 315 1
Position and
dimensions of arc and All types of the same
stripes category 200 6.5
Starting, run-up and All types of the same
hot-restrike category 200 1
Lamp voltage and All types of the same
wattage category 200 1
Luminous flux,
colour and All types of the same
UV radiation category 200 1
* The assessment shall in general cover series production gas-discharge light sources from
individual factories. A manufacturer may group together records concerning the same type from
several factories, provided these operate under the same quality system and quality management.
Qualifying limits for acceptance based on different numbers of test results for each
grouping of characteristics are listed in table 2 as maximum number of non-compliances.
The limits are based on an acceptable level of 1 per cent of non-compliances, assuming an
acceptance probability of at least 0.95.Number of test results of each characteristics Qualifying limits for acceptance
- 200 5 201 - 260 6 261 - 315 7 316 - 370 8 371 - 435 9 436 - 500 10 501 - 570 11 571 - 645 12 646 - 720 13 721 - 800 14 801 - 860 15 861 - 920 16 921 - 990 17 991 - 1060 18 1061 - 1125 19 1126 - 1190 20 1191 - 1249 21 Annex 7 Qualifying limits for acceptance based on different numbers of test results for each grouping of characteristics are listed in table 3 given as maximum number of non- compliances. The limits are based on an acceptable level of 6.5 per cent of non- compliances, assuming an acceptance probability of at least 0.95.
Number of Number of Number of lamps in Qualifying lamps in Qualifying lamps in Qualifying records limit records limit records limit - 200 21 541 - 553 47 894 - 907 73 201 - 213 22 554 - 567 48 908 - 920 74 214 - 227 23 568 - 580 49 921 - 934 75 228 - 240 24 581 - 594 50 935 - 948 76 241 - 254 25 595 - 608 51 949 - 961 77 255 - 268 26 609 - 621 52 962 - 975 78 269 - 281 27 622 - 635 53 976 - 988 79 282 - 295 28 636 - 648 54 989 - 1002 80 296 - 308 29 649 - 662 55 1003 -1016 81 309 - 322 30 663 - 676 56 1017 - 1029 82 323 - 336 31 677 - 689 57 1030 - 1043 83 337 - 349 32 690 - 703 58 1044 - 1056 84 350 - 363 33 704 - 716 59 1057 - 1070 85 364 - 376 34 717 - 730 60 1071 - 1084 86 377 - 390 35 731 - 744 61 1085 - 1097 87 391 - 404 36 745 - 757 62 1098 - 1111 88 405 - 417 37 758 - 771 63 1112 - 1124 89 418 - 431 38 772 - 784 64 1125 - 1138 90 432 - 444 39 785 - 798 65 1139 - 1152 91 445 - 458 40 799 - 812 66 1153 - 1165 92 459 - 472 41 813 - 825 67 1166 - 1179 93 473 - 485 42 826 - 839 68 1180 - 1192 94 486 - 499 43 840 - 852 69 1193 - 1206 95 500 - 512 44 853 - 866 70 1207 - 1220 96 513 - 526 45 867 - 880 71 1221 - 1233 97 527 - 540 46 881 - 893 72 1234 - 1249 98 Qualifying limits for acceptance based on different numbers of test results for each grouping of characteristics are listed in table 4 given as a percentage of the results, assuming an acceptance probability of at least 0.95.
Qualifying limits shown as a Qualifying limits shown as a
percentage of results. percentage of results.
Number of test results of each Acceptable level of 1 per cent of Acceptable level of 6.5 per cent of
characteristic non-compliances non-compliances
1 250 1.68 7.91
2 000 1.52 7.61
4 000 1.37 7.29
6 000 1.30 7.15
8 000 1.26 7.06
10 000 1.23 7.00
20 000 1.16 6.85
40 000 1.12 6.75
80 000 1.09 6.68
100 000 1.08 6.65
1 000 000 1.02 6.55
Annex 8Annex 8 — Minimum requirements for sampling by an inspector
The conformity requirements shall be considered satisfied from a photometric, geometrical, visual and electrical standpoint if the specified tolerances for production gas-discharge light sources in the relevant data sheet of Annex 1 and the relevant data sheet for the caps are met.
The conformity of mass-produced gas-discharge light sources shall not be contested if the results are in agreement with paragraph 5 of this annex.
Conformity shall be contested and the manufacturer requested to make the production meet the requirements if the results are not in agreement with paragraph 5 of this annex.
If paragraph 3 of this annex is applied, a further sample of 250 gas-discharge light sources, selected at random from a recent production run, shall be taken within two months.
Compliance approved or disapproved shall be decided according to the values in table 1. For each grouping of characteristics gas-discharge light sources shall be either accepted or rejected according to the values in table 1*.
1 per cent** 6.5 per cent**
Sample Accept Reject Accept Reject First sample size: 125 2 5 11 16 If the number of non-conforming units 6 7 26 27 is greater than 2 (11) and less than 5 (16) take a second sample size of 125 and assess the 250 * The proposed scheme is designed to assess the compliance of gas-discharge light sources to an acceptance level of non-compliance of 1 per cent and 6.5 per cent respectively and is based on the Double Sampling Plan for Normal Inspection in IEC Publication 60410: Sampling Plans and Procedures for Inspection by Attributes. ** The gas-discharge light sources shall be inspected and test results recorded following the grouping of characteristics as listed in Annex 7 to this Regulation, table 1.