Compare versions of (EU) 2017/2400
Implementing Regulation (EC) No 595/2009 of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles and amending Directive 2007/46/EC of the European Parliament and of the Council and Commission Regulation (EU) No 582/2011 (Text with EEA relevance. )
Consolidated text 01.03.2019 → latestConsolidated text 01.09.2020 → latestConsolidated text 01.07.2022 → latestConsolidated text 01.01.2023 → latestConsolidated text 01.01.2024 → latestConsolidated text 01.03.2025 → latest
Gerekce (preamble)deleted
Article 1changed
This Regulation complements the legal framework for the type-approval of motor vehicles and engines with regard to emissions and vehicle repair and maintenance information established by Regulation (EU) No 582/2011 by laying down the rules for issuing licences to operate a simulation tool with a view to determining CO2 emissions and fuel consumption of new vehicles to be sold, registered or put into service in the Union and for operating that simulation tool and declaring the CO2 emissions and fuel consumption values thus determined.
1.changed
Subject to the second paragraph of Article 4, second paragraph, this Regulation shall apply to vehicles of category N2, as defined in Annex II to Directive 2007/46/EC, with a technically permissible maximum laden mass exceeding 7 500 kg medium lorries, heavy lorries and to all vehicles of category N3, as defined in that Annex. heavy buses.
2.changed
In the case of multi-stage type-approvals or individual approvals of vehicles referred to in paragraph 1, medium and heavy lorries, this Regulation shall apply only to base lorries. In the case of heavy buses, this Regulation shall apply to primary vehicles, interim vehicles equipped at least with a chassis, engine, transmission, axles and tyres. to complete vehicles or completed vehicles.
3.changed
This Regulation shall not apply to off-road vehicles, special purpose vehicles and off road off-road special purpose vehicles as defined, respectively, in Part A, points 2.1., 2.2. and 2.3. of Part A 2.3., of Annex II I to Directive 2007/46/EC. Regulation (EU) 2018/858 of the European Parliament and of the Council ( 1 ).
Article 3changed
For the purposes of this Regulation, the following definitions shall apply: ‘CO2 emissions and fuel consumption related properties’ means specific properties derived for a component, separate technical unit and system which determine the impact of the part on the CO2 emissions and fuel consumption of a vehicle; ‘input data’ means information on the CO2 emissions and fuel consumption related properties of a component, separate technical unit or system which is used by the simulation tool for the purpose of determining CO2 emissions and fuel consumption of a vehicle; ‘input information’ means information relating to the characteristics of a vehicle which is used by the simulation tool for the purposes of determining their CO2 emissions and fuel consumption of the vehicle and which is not part of an input data; ‘manufacturer’ means the person or body who is responsible to the approval authority for all aspects of the certification process and for ensuring conformity of CO2 emissions and fuel consumption related properties of components, separate technical units and systems. It is not essential that the person or body be directly involved in all stages of the construction of the component, separate technical unit or system which is the subject of the certification. ‘vehicle manufacturer’ means a body or person responsible for issuing the manufacturer's records file and the customer information file pursuant to Article 9; ‘authorised entity’ means a national authority authorised by a Member State to request relevant information from the manufacturers and vehicle manufacturers on the CO2 emissions and fuel consumption related properties of a specific component, specific separate technical unit or specific system and CO2 emissions and fuel consumption of new vehicles respectively. ‘transmission’ means a device consisting of at least of two shiftable gears, changing torque and speed with defined ratios; ‘torque converter’ means a hydrodynamic start-up component either as a separate component of the driveline or transmission with serial or parallel power flow that adapts speed between engine and wheel and provides torque multiplication; ‘other torque transferring component’ or ‘OTTC’ means a rotating component attached to the driveline which produces torque losses dependent on its own rotational speed; ‘additional driveline component’ or ‘ADC’ means a rotating component of the driveline which transfers or distributes power to other driveline components and produces torque losses dependant on its own rotational speed; ‘axle’ means a central shaft for a rotating wheel or gear as drive axle of a vehicle; ‘air drag’ means characteristic of a vehicle configuration regarding aerodynamic force acting on the vehicle opposite to the direction of air flow and determined as a product of the drag coefficient and the cross sectional area for zero crosswind conditions; ‘auxiliaries’ means vehicle components including an engine fan, steering system, electric system, pneumatic system and air conditioning (AC) system whose CO2 emissions and fuel consumption properties have been defined in Annex IX; ‘component family’, ‘separate technical unit family’ or ‘system family’ means a manufacturer's grouping of components, separate technical units or systems, respectively, which through their design have similar CO2 emissions and fuel consumption related properties; ‘parent component’, ‘parent separate technical unit’ or ‘parent system’ means a component, separate technical unit or system, respectively, selected from a component, separate technical unit or system family, respectively, in such a way that its CO2 emissions and fuel consumption related properties will be the worst case for that component family, separate technical unit family or system family; ‘zero emission heavy-duty vehicle’ or ‘ZE-HDV’ means a heavy-duty vehicle without an internal combustion engine, or with an internal combustion engine that emits less than 1 g CO2/kWh; ‘vocational vehicle’ means a heavy-duty vehicle not intended for the delivery of goods and for which one of the following digits is used to supplement the bodywork codes, as listed in Appendix 2 to Annex II of Directive 2007/46/EC: 09, 10, 15, 16, 18, 19, 20, 23, 24, 25, 26, 27, 28, 31; or a tractor with a maximum speed not exceeding 79 km/h; ‘rigid lorry’ means a lorry that is not designed or constructed for the towing of a semi-trailer; ‘tractor’ means a tractor unit that is designed and constructed exclusively or principally to tow semi-trailers; ‘sleeper cab’ means a type of cabin that has a compartment behind the driver's seat intended to be used for sleeping; ‘hybrid electric heavy-duty vehicle’ or ‘He-HDV’ is as defined in Article 3(15) of Directive 2007/46/EC; ‘dual-fuel vehicle’ is as defined in Article 2(48) of Regulation (EU) No 582/2011. With regard to He-HDVs, Articles 5(3), 9(1) and 12(1) shall apply only to He-HDVs where the second highest maximum net power of all energy converters is less than 10 % of the highest maximum net power of all energy converters. Energy converters used only for the starting are in this respect not taken into consideration.
(1)changed
(2)changed
(3)changed
(4)changed
(5)changed
(6)changed
(7)changed
(8)changed
(9)changed
(10)added
‘axle’ means a component comprising all rotating parts of the driveline which transfer the driving torque coming from the prop shaft to the wheels and changes the torque and speed with a fixed ratio and including the functions of a differential gear;
(11)added
‘air drag’ means characteristic of a vehicle configuration regarding aerodynamic force acting on the vehicle in the direction of air flow and determined as a product of the drag coefficient and the cross sectional area for zero crosswind conditions;
(12)added
‘auxiliaries’ means vehicle components including an engine fan, steering system, electric system, pneumatic system and Heating, Ventilation and Air Conditioning (HVAC) system whose CO2 emissions and fuel consumption properties have been defined in Annex IX;
(13)added
‘component family’, ‘separate technical unit family’ or ‘system family’ means a manufacturer's grouping of components, separate technical units or systems, respectively, which through their design have similar CO2 emissions and fuel consumption related properties;
(14)added
‘parent component’, ‘parent separate technical unit’ or ‘parent system’ means a component, separate technical unit or system, respectively, selected from a component, separate technical unit or system family, respectively, in such a way that its CO2 emissions and fuel consumption related properties will be the worst case for that component family, separate technical unit family or system family;
(15)added
‘zero emission heavy-duty vehicle’ (Ze-HDV) means ‘zero emission heavy-duty vehicle’ as defined in Article 3, point (11), of Regulation (EU) 2019/1242 of the European Parliament and of the Council;
(16)added
‘vocational vehicle’ means a heavy-duty vehicle not intended for the delivery of goods and for which one of the following digits is used to supplement the bodywork codes, as listed in Appendix 2 to Annex I to Regulation (EU) 2018/858: 09, 10, 15, 16, 18, 19, 20, 23, 24, 25, 26, 27, 28, 31; or a tractor with a maximum speed not exceeding 79 km/h;
(17)added
‘rigid lorry’ means a ‘lorry’ as defined in Part C, point 4.1, of Annex I to Regulation (EU) 2018/858, except for the lorries designed or constructed for the towing of a semi-trailer;
(18)added
‘tractor’ means a ‘tractor unit for semi-trailer’ as defined in Part C, point 4.3, of Annex I to Regulation (EU) 2018/858
(19)added
‘sleeper cab’ means a type of cabin that has a compartment behind the driver's seat intended to be used for sleeping;
(20)added
‘hybrid electric heavy-duty vehicle’ (He-HDV) means a hybrid heavy duty vehicle that, for the purpose of mechanical propulsion, draws energy from both of the following on-vehicle sources of stored energy or power: (i) a consumable fuel, and (ii) an electrical energy or power storage device;
(21)added
‘dual-fuel vehicle’ is as defined in Article 2(48) of Regulation (EU) No 582/2011;
(22)added
‘primary vehicle’ means a heavy bus in a virtual assembly condition determined for simulation purposes, for which the input data and input information as set out in Annex III is used;
(23)added
‘manufacturer’s records file’ means a file produced by the simulation tool which contains manufacturer related information, a documentation of the input data and input information to the simulation tool and the results for CO2 emissions and fuel consumption;
(24)added
‘customer information file’ means a file produced by the simulation tool which contains a defined set of vehicle related information and the results for CO2 emissions and fuel consumption as defined in Part II of Annex IV;
(25)added
‘vehicle information file’ (VIF) means a file produced by the simulation tool for heavy buses to transfer the relevant input data, input information and simulation results to subsequent manufacturing stages following the method as described in point (2) of Annex I;
(26)added
‘medium lorry’ means a vehicle of category N2, as defined in Article 4(1), point (b)(ii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass exceeding 5 000 kg and not exceeding 7 400 kg;
(27)added
‘heavy lorry’ means a vehicle of category N2, as defined in Article 4(1), point (b)(ii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass exceeding 7 400 kg and a vehicle of category N3, as defined in Article 4(1), point (b)(iii), of that Regulation;
(28)added
‘heavy bus’ means a vehicle of category M3, as defined in Article 4(1), point (a)(iii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass of more than 7 500 kg;
(29)added
‘primary vehicle manufacturer’ means a manufacturer responsible for the primary vehicle;
(30)added
‘interim vehicle’ means any further completion of a primary vehicle where a sub-set of input data and input information as defined for the complete or completed vehicle in accordance with Table 1 and Table 3a of Annex III is added and/or modified;
(31)added
‘interim manufacturer’ means a manufacturer responsible for an interim vehicle;
(32)added
‘incomplete vehicle’ means ‘incomplete vehicle’ as defined in Article 3, point (25), of Regulation (EU) 2018/858;
(33)added
‘completed vehicle’ means ‘completed vehicle’ as defined in Article 3, point (26), of Regulation (EU) 2018/858;
(34)added
‘complete vehicle’ means ‘complete vehicle’ as defined in Article 3, point (27), of Regulation (EU) 2018/858;
(35)added
‘standard value’ is input data for the simulation tool for a component where certification of input data is applicable, but the component has not been tested to determine a specific value and which reflects the worst-case performance of a component;
(36)added
‘generic value’ is data used in the simulation tool for components or vehicle parameters where no component testing or declaration of specific values is foreseen and which reflects performance of average component technology or typical vehicle specifications;
(37)added
‘van’ means a ‘van’ as defined in Part C, point 4.2, of Annex I to Regulation (EU) 2018/858;
(38)added
‘application case’ means the different scenarios to be followed in the case of a medium lorry, heavy lorry, heavy bus that is a primary vehicle, heavy bus that is an interim vehicle, heavy bus that is a complete vehicle or completed vehicle for which different manufacturer provisions and functions are applicable in the simulation tool;
(39)added
‘base lorry’ means a medium lorry or heavy lorry equipped at least with:
Article 4changed
For the purpose of this Regulation, motor vehicles shall be classified in vehicle groups in accordance with Table Annex I, Tables 1 in Annex I. to 6. Articles 5 to 22 23 do not apply to motor vehicles heavy lorries of vehicle groups 0, 6, 7, 8, 13, 14, 15 15, 17, 18 and 17. 19 as set out in Table 1 of Annex I, and to medium lorries of vehicle groups 51, 52, 55 and 56, as set out in Table 2 of Annex I and to any vehicle with a driven front axle in the vehicle groups 11, 12 and 16 as set out in Table 1 of Annex I.
1.changed
The vehicle manufacturer Commission shall submit provide free of charge the following electronic tools in the form of downloadable and executable software: (a) a simulation tool; (b) pre-processing tools; (c) a hashing tool. The Commission shall maintain the electronic tools and provide modifications and updates to the approval authority an application for a licence to operate the simulation tool referred to in Article 5(3) with a view to determining CO2 emissions and fuel consumption of new vehicles belonging to one or more vehicle groups (‘licence’). those tools.
2.changed
The application for Commission shall make the electronic tools referred to in paragraph 1 available through a licence shall take the form of an information document drawn up in accordance with the model set out in Appendix 1 to Annex II. publicly available dedicated electronic distribution platform.
3.changed
►M3 The application for a licence simulation tool shall be accompanied by an adequate description of the processes set up by the manufacturer used for the purposes of determining CO2 emissions and fuel consumption with respect of new vehicles. ◄ The simulation tool shall be designed to all operate on the vehicle groups concerned, basis of input information as set out specified in point 1 of Annex II. It shall also be accompanied by the assessment report drafted by the approval authority after performing an assessment III, as well as input data referred to in accordance with point 2 of Annex II. Article 12(1).
4.changed
The vehicle manufacturer pre-processing tools shall submit be used for the application for purpose of verification and compilation of the testing results and performing additional calculations relating to CO2 emission and fuel consumption related properties of certain components, separate technical units or systems and converting them in a licence drawn up in accordance with paragraphs 2 and 3 to the approval authority at the latest together with the application for an EC type-approval of a vehicle with an approved engine system with regard to emissions and access to vehicle repair and maintenance information pursuant to Article 7 of Regulation (EU) No 582/2011, or with the application for an EC type-approval of a vehicle with regard to emissions and access to vehicle repair and maintenance information pursuant to Article 9 of that Regulation. The application for a licence must concern the vehicle group which includes the type of vehicle concerned format used by the application simulation tool. The pre-processing tools shall be used by the manufacturer after performing the tests referred to in point 4 of Annex V for EC type-approval. engines and in point 3 of Annex VIII for air-drag.
5.changed
1.changed
The vehicle manufacturer shall submit to the approval authority shall grant the licence if the manufacturer submits an application in accordance for a licence to operate the simulation tool for an application case with Article 6 a view to determining CO2 emissions and proves that fuel consumption of new vehicles belonging to one or more vehicle groups (‘licence’). An individual licence shall apply to only a single such application case. The application for a licence shall be accompanied by an adequate description of the requirements laid down in Annex II are met processes set up by the vehicle manufacturer with a view to the operation of the simulation tool with respect to the vehicle groups concerned. Where the requirements laid down application case concerned, as set out in point (1) of Annex II are met only with respect to some of the vehicle groups specified in the application for a licence, the licence shall be granted only with respect to those vehicle groups. II.
2.changed
The application for a licence shall be issued take the form of an information document drawn up in accordance with the model set out in Appendix 2 1 to Annex II.
3.changed
4.changed
1.changed
2.changed
The vehicle manufacturer licence shall apply for an extension of the licence be issued in accordance with Article 6 (1), (2) and (3). the model set out in Appendix 2 to Annex II.
2.changed
The vehicle manufacturer shall record the results apply for an extension of the simulation performed licence in accordance with the first subparagraph of paragraph 1 in the manufacturer's records file drawn up in accordance with the model set out in Part I of Annex IV. With the exception of the cases referred to in the second subparagraph of Article 21(3), 6 (1), (2) and in Article 23(6), any subsequent changes to the manufacturer's records file shall be prohibited. (3).
3.changed
4.changed
5.changed
1.changed
A vehicle manufacturer shall determine the CO2 emissions and fuel consumption of each new vehicle, with the exception of ZE-HDVs, He-HDVs and dual-fuel vehicles, new vehicles using vehicle technologies listed in Appendix 1 to Annex III, to be sold, registered or put into service in the Union using the latest available version of the simulation tool referred to in Article 5(3). With regard to ZE-HDVs, He-HDVs and dual-fuel vehicles heavy buses the vehicle manufacturer or interim manufacturer shall use the method set out in Annex I, point (2). For vehicle technologies listed in Appendix 1 to Annex III to be sold, registered or put into service in the Union, the vehicle manufacturer or interim manufacturer shall determine only the information input parameters specified for those vehicles in the models set out in Part I and Part II Table 5 of Annex IV III, using the latest available version of the simulation tool referred to in Article 5(3). A vehicle manufacturer may operate the simulation tool for the purposes of this Article only if in possession of a licence granted for the vehicle group application case concerned in accordance with Article 7 or extended to 7. An interim manufacturer operates the simulation tool under the licence of a vehicle group concerned in accordance with Article 8(1). manufacturer.
2.changed
3.changed
4.changed
5.changed
6.changed
2.changed
3.changed
1.changed
The manufacturer's manufacturer’s records file, the vehicle information file together with and the certificates on CO2 emissions and fuel consumption related properties of the components, systems and separate technical units shall be stored by the vehicle manufacturer for at least 20 years after the production of the vehicle and shall be available available, upon request, to the approval authority and to the Commission at their request. Commission.
2.changed
3.changed
1.changed
The simulation tool input data referred to in Article 5(3) shall include information relating to the CO2 emissions and fuel consumption related properties of the following components, separate technical units and systems: (a) engines; (b) transmissions; (c) torque converters; (d) other torque transferring components; (e) additional driveline components; (f) axles; body or trailer ▼M3 (g) air drag; ▼B (h) auxiliaries; tyres. (i) tyres; ▼M3 (j) electric powertrain components; ▼M4 (k) wheel ends.
2.changed
The CO2 emissions and fuel consumption related properties of the components, separate technical units and systems referred to in points (b) to (g), (i), (j) and (k) of paragraph 1 of this Article shall be based either on the values determined, for each component, separate technical unit, system or if applicable their respective family, in accordance with Article 14 and certified in accordance with Article 17 (‘certified values’) or, in the absence of the certified values, on the standard values for torque converters shall be determined in accordance with Appendix 9 of Annex VI. Article 13.
3.changed
The standard values for other torque-transferring components CO2 emissions and fuel consumption related properties of engines shall be based on the values determined for each engine family in accordance with Appendix 10 of Annex VI. Article 14 and certified in accordance with Article 17.
4.changed
The standard CO2 emissions and fuel consumption related properties of auxiliaries shall be based on the generic values for additional driveline components shall as implemented in the simulation tool and as allocated to a vehicle based on the input information to be determined in accordance with Appendix 11 of Annex VI. IX.
5.changed
6.changed
7.changed
2.changed
The certified standard values for engines torque converters shall be determined in accordance with point 4 Appendix 9 of Annex V. VI.
3.changed
The certified standard values for transmissions other torque-transferring components shall be determined in accordance with point 3 Appendix 10 of Annex VI.
4.changed
The certified standard values for torque converters additional driveline components shall be determined in accordance with point 4 Appendix 11 of Annex VI.
5.changed
The certified standard values for other torque-transferring component axles shall be determined in accordance with point 5 Appendix 3 of Annex VI. VII.
6.changed
7.changed
8.changed
The certified values standard value for a body or trailer air drag tyres shall be determined in accordance with Annex X, point 3 of Annex VIII. 3.2.
9.added
The standard values for electric powertrain components shall be determined in accordance with Appendices 8, 9, 10 and 11 to Annex Xb.
10.added
The standard values for wheel ends shall be determined in accordance with point 6 of Annex VIIa.
1.changed
The values determined in accordance with paragraphs 2 to 9 11 of this Article may be used by the vehicle manufacturer as the simulation tool input data if they are certified in accordance with Article 17.
2.changed
3.changed
The CO2 emissions and fuel consumption related properties certified values for transmissions shall be determined in accordance with point 3 of the parent component, parent separate technical unit or parent system shall not be better than the properties of any member of the same family. Annex VI.
4.changed
The manufacturer certified values for torque converters shall provide the approval authority be determined in accordance with evidence that the parent component, separate technical units or system fully represents the component family, separate technical unit family or system family. If, in the framework point 4 of testing for the purposes of the second subparagraph of Article 16(3), the approval authority determines that the selected parent component, parent separate technical unit or parent system does not fully represent the component family, separate technical unit family or system family, an alternative reference component, separate technical units or system may be selected by the approval authority, tested and shall become a parent component, parent separate technical unit or parent system. Annex VI.
5.changed
6.changed
7.added
The certified values for axles shall be determined in accordance with point 4 of Annex VII.
8.added
The certified values for air drag shall be determined in accordance with point 3 of Annex VIII.
9.added
The certified values for tyres shall be determined in accordance with Annex X.
10.added
The certified values for electric powertrain components shall be determined in accordance with points 4, 5 and 6 of Annex Xb.
11.added
The certified values for wheel ends shall be determined in accordance with Annex VIIa.
1.changed
Subject to paragraphs 3 to 6, the certified values determined for a parent component, parent separate technical unit or parent system shall be valid, without further testing, for all family members in accordance with the family definition as set out in: — Appendix 6 to Annex VI as regards the family concept of transmissions, torque converters, other torque transferring component and additional driveline components; — Appendix 4 to Annex VII as regards the family concept of axles; — Appendix 5 to Annex VIII as regards the family concept for the purposes of determining air drag; ▼M3 — Appendix 3 to Annex V as regards engines, the certified values for the members of an engine family created in accordance with the family definition shall be derived in accordance with points 4, 5 and 6 of Annex V; — Appendix 13 to Annex Xb as regards the family concept of electric machine systems or integrated electric powertrain components, the certified values for the members of a family created in accordance with the family definition of electric machine systems, shall be derived in accordance with point 4 of Annex Xb; ▼M4 — Annex VIIa as regards the family concept of wheel ends.
2.changed
3.changed
The application for certification shall be accompanied by an explanation of the elements of design of the component family, separate technical unit family or the system family concerned which have a non-negligible effect on the CO2 emissions and fuel consumption related properties of the components, parent component, parent separate technical units unit or systems concerned. The application parent system shall also not be accompanied by better than the relevant test reports issued by an approval authority, test results, and by a statement properties of compliance issued by an approval authority pursuant to point 1 any member of Annex X of Directive 2007/46/EC. the same family.
4.changed
The manufacturer shall provide the approval authority shall create a cryptographic hash with evidence that the parent component, separate technical units or system fully represents the component family, separate technical unit family or system family. If, in the framework of testing for the purposes of the file with test results, comprising second subparagraph of Article 16(3), the certification number, by means of the hashing tool referred to in Article 5(5). This hashing shall be done immediately after the test results are produced. The approval authority determines that the selected parent component, parent separate technical unit or parent system does not fully represent the component family, separate technical unit family or system family, an alternative reference component, separate technical units or system may be selected by the approval authority, tested and shall imprint that hash along with the certification number on the certificate on CO2 emissions and fuel consumption related properties. become a parent component, parent separate technical unit or parent system.
5.changed
6.added
Where the characteristics of the specific component, specific separate technical unit or specific system, in terms of CO2 emissions and fuel consumption related properties as determined in accordance with paragraph 5, lead to higher CO2 emissions and fuel consumption values than those of the parent component, parent separate technical unit or parent system, respectively, the manufacturer shall exclude it from the existing family, assign it to a new family and define it as the new parent component, parent separate technical unit or parent system for that family or apply for an extension of the certification pursuant to Article 18.
1.changed
The application for certification of the CO2 emissions and fuel consumption related properties of the component family, component, separate technical unit family and systems, or system family if applicable their respective families, shall be submitted to the approval authority.
2.changed
3.changed
The approval authority application for certification shall grant a certification number in accordance with be accompanied by an explanation of the numbering system set out in: The approval authority shall not assign elements of design of the same number to another component family, component, separate technical unit family and system, or system family. The certification number shall be used as if applicable their respective families concerned which have a non-negligible effect on the identifier CO2 emissions and fuel consumption related properties of the components, separate technical units or systems concerned. The application shall also be accompanied by the relevant test report. reports issued by an approval authority, test results, and by a statement of compliance issued by an approval authority pursuant to point 2 of Annex IV to Regulation (EU) 2018/858.
1.changed
If all the applicable requirements are met, the approval authority shall certify the values relating to the CO2 emissions and fuel consumption related properties of the component family, component, separate technical unit family and system, or system family if applicable their respective families concerned.
2.changed
3.changed
4.changed
The manufacturer approval authority shall create a cryptographic hash of the file with test results, comprising the certification number, by means of the hashing tool referred to in Article 5(5). This hashing shall be responsible for done immediately after the execution of test results are produced. The approval authority shall imprint that hash along with the approved plan of remedial measures. certification number on the certificate on CO2 emissions and fuel consumption related properties.
SECTION Ideleted
1.changed
At the request of the manufacturer and upon approval of the approval authority, a new component, separate technical unit or system may be included as a member of a certified component family, separate technical unit family or system family if they meet the criteria for family definition set out in: ▼M3 — Appendix 3 to Annex V as regards the family concept of engines, taking into account the requirements of Article 15(2); ▼B — Appendix 6 to Annex VI as regards the family concept of transmissions, torque converters, other torque transferring component and additional driveline components; — Appendix 4 to Annex VII as regards the family concept of axles; — Appendix 5 to Annex VIII as regards the family concept for the purposes of determining air drag; ▼M3 — Appendix 13 to Annex Xb as regards the family concept of electric machine systems or integrated electric powertrain components, taking into account the requirements of Article 15(2); ▼M4 — Annex VIIa as regards the family concept of wheel ends. ▼B In such cases, the approval authority shall issue a revised certificate denoted by an extension number. The manufacturer shall modify the information document referred to in Article 16(2) and provide it to the approval authority.
1. Additional informationdeleted
2.changed
2.changed
SECTION Ideleted
3.changed
1. Additional informationdeleted
1.changed
►M3 The vehicle manufacturer shall take the necessary measures to ensure that the processes set up for the purposes purpose of determining CO2 emissions and fuel consumption obtaining the licence for all the vehicle groups simulation tool for the application case covered by the licence granted pursuant to Article 7 or the extension to the licence pursuant to Article 8(1) continue to be adequate for that purpose. The ◄ ►M3 For medium lorries and heavy lorries, with the exception of He-HDV or PEV, the vehicle manufacturer shall, on a yearly basis, perform the verification testing procedure set out in Annex Xa on a minimum number of vehicles in accordance with that Annex, point 3 of that Annex. 3. ◄ The vehicle manufacturer shall provide, until 31 December of each year and in accordance with point 8 of Annex Xa, a test report to the approval authority for each vehicle tested, shall keep the test reports for a duration of at least 10 years and shall make them available to the Commission and approval authorities of the other Member States upon request.
2.changed
►M3 The plan approval authority shall perform, four times per year, an assessment as referred to in point 2 of remedial measures shall apply Annex II in order to verify whether the processes set up by the manufacturer for the purposes of determining CO2 emissions and fuel consumption for all the application cases and vehicle groups which have been identified covered by the licence continue to be adequate. ◄ The assessment shall also include verification of the selection of the input information and input data and repetition of the simulations performed by the manufacturer, Where a vehicle fails the verification testing procedure set out in Annex Xa, the approval authority shall start an investigation to determine the cause of that failure, in its request. accordance with Annex Xa. As soon as the approval authority determines the cause of the failure, it shall inform the approval authorities of the other Member States thereof. If the cause of the failure is linked to the operation of the simulation tool, Article 21 shall apply. If the cause of the failure is linked to the certified CO2 emissions and fuel consumption related properties of components, separate technical units and systems, Article 23 shall apply. If no irregularities could be found in the certification of components, separate technical units or systems and the operation of the simulation tool, the approval authority shall report the vehicle failure to the Commission. The Commission shall investigate whether the simulation tool or the verification testing procedure set out in Annex Xa has caused the vehicle to fail and whether an improvement of the simulation tool or the verification testing procedure is necessary.
2. Definitionsdeleted
4. Vehicle massdeleted
2.changed
The manufacturer plan of remedial measures shall provide, on an annual basis, testing reports containing the results of the procedures referred apply to in the second subparagraph of paragraph 1 to all application cases and vehicle groups which have been identified by the approval authority which certified the CO2 emissions and fuel consumption related properties of the component family, separate technical unit family or system family concerned. The manufacturer shall make the test reports available to the Commission upon in its request.
3.changed
The manufacturer shall ensure that at least one in every 25 procedures referred to in the second subparagraph of paragraph 1, or, with an exception for tyres, at least one procedure per year, relating to a component family, separate technical unit family or system family is supervised by a different approval authority than shall approve or reject the one which participated in plan of remedial measures within 30 calendar days of its receipt. The approval authority shall notify the certification manufacturer and all the other Member States of its decision to approve or reject the plan of remedial measures. The approval authority may require the vehicle manufacturer to issue a new manufacturer’s records file, vehicle information file, customer information file and certificate of conformity on the basis of a new determination of CO2 emissions and fuel consumption related properties reflecting the changes implemented in accordance with the approved plan of remedial measures. The vehicle manufacturer shall take the component family, separate technical unit family or system family concerned necessary measures to ensure that the processes set up for the purpose of obtaining the licence to operate the simulation tool for all the application cases and vehicle groups covered by the licence granted pursuant to Article 16. 7 continue to be adequate for that purpose. For medium lorries and heavy lorries the vehicle manufacturer shall, perform the verification testing procedure set out in Annex Xa on a minimum number of vehicles in accordance with that Annex, point 3.
4.changed
5.changed
1.changed
►M3 The manufacturer shall take the necessary measures in accordance with Annex IV to Annex X to Directive 2007/46/EC Regulation (EU) 2018/858 to ensure that the CO2 emissions and fuel consumption related properties of the components, separate technical units and systems listed in Article 12(1) which have been the subject of certification in accordance with Article 17 do not deviate from the certified values. ◄ Those measures shall also include the following: Where CO2 emissions and fuel consumption related properties of a member of a component family, separate technical unit family or system family have been certified in accordance with Article 15(5), the reference value for the verification of the CO2 emissions and fuel consumption related properties shall be the one certified for this family member. Where a deviation from the certified values is identified as a result of the measures referred to in the first and second subparagraphs, the manufacturer shall immediately inform the approval authority thereof.
1.1. Vehicle datadeleted
1.4. Retarder specificationsdeleted
—added
Where CO2 emissions and fuel consumption related properties of a member of a component family, separate technical unit family or system family have been certified in accordance with Article 15(5), the reference value for the verification of the CO2 emissions and fuel consumption related properties shall be the one certified for this family member.
Where a deviation from the certified values is identified as a result of the measures referred to in the first and second subparagraphs, the manufacturer shall immediately inform the approval authority thereof.
2.changed
The plan manufacturer shall provide, on an annual basis, testing reports containing the results of remedial measures shall apply the procedures referred to all in the second subparagraph of paragraph 1 to the approval authority which certified the CO2 emissions and fuel consumption related properties of the component families, family, separate technical unit families family or system families which have been identified by family concerned. The manufacturer shall make the approval authority in its test reports available to the Commission upon request.
3.changed
The manufacturer shall ensure that at least one in every 25 procedures referred to in the second subparagraph of paragraph 1, or, with an exception for tyres, at least one procedure per year, relating to a component, separate technical unit and system, or if applicable their respective families is supervised by a different approval authority shall approve or reject than the plan one which participated in the certification of remedial measures within 30 calendar days of its receipt. The approval authority shall notify the manufacturer and all the other Member States of its decision to approve or reject the plan of remedial measures. The approval authority may require the vehicle manufacturers who installed the components, separate technical units and systems concerned in their vehicles to issue a new manufacturer's records file, customers information file and certificate of conformity on the basis of the CO2 emissions and fuel consumption related properties of those components, the component, separate technical units and systems obtained by means of the measures referred unit, system or if applicable their respective families concerned pursuant to in Article 22(1). 16.
1.7. Axle specificationsdeleted
4.changed
Any approval authority may at any time perform verifications relating to the components, separate technical units and systems at any of the manufacturer's and vehicle manufacturer's facilities in order to verify whether the CO2 emissions and fuel consumption related properties of those components, separate technical units and systems do not deviate from the certified values. The manufacturer and the vehicle manufacturer shall be responsible for provide the execution approval authority within 15 working days of the approved plan of remedial measures. approval authority's request with all the relevant documents, samples and other materials in his possession and necessary to perform the verifications relating to a component, separate technical unit or system.
1.8. Aerodynamicsdeleted
2.changed
3.changed
The second subparagraph approval authority shall approve or reject the plan of Article 20(1) remedial measures within 30 calendar days of its receipt. The approval authority shall notify the manufacturer and all the second, third other Member States of its decision to approve or reject the plan of remedial measures. The approval authority may require the vehicle manufacturer to issue a new manufacturer’s records file, customer information file, vehicle information file and fourth subparagraphs certificate of Article 20(2) shall apply from 1 July 2020. Remedial measures under Articles 21(5) conformity on the basis of a new determination of CO2 emissions and 23(6) shall apply pursuant to an investigation into a vehicle failure fuel consumption reflecting the changes implemented in accordance with the verification testing procedure set out in Annex Xa as from 1 July 2023. approved plan of remedial measures.
4.added
The manufacturer shall be responsible for the execution of the approved plan of remedial measures.
5.added
The manufacturer shall keep a record of every component, separate technical unit or system recalled and repaired or modified and of the workshop which performed the repair or modification. The approval authority shall have access to such records on request during the implementation of the plan of the remedial measures and for a period of 5 years after the completion of its implementation.
The manufacturer shall store those records for 10 years.
6.added
Where the plan of remedial measures has been rejected by the approval authority, or the approval authority establishes that the remedial measures are not being correctly applied, it shall take the necessary measures to ensure the conformity of CO2 emissions and fuel consumption related properties of the component, separate technical unit and system, and if applicable their respective families concerned, or withdraw the certificate on CO2 emissions and fuel consumption related properties.
2.3. Fuel and CO2 resultsdeleted
Article 24added
Without prejudice to Article 10(3) of this Regulation, where the obligations referred to in Article 9 of this Regulation have not been complied with, Member States shall consider certificates of conformity for type approved vehicles to be no longer valid for the purposes of Article 48 of Regulation (EU) 2018/858, and, for type approved vehicles and individually approved vehicles, shall prohibit the registration, sale or entry into service of vehicles in groups 1s, 1, 2, 3, 4, 5, 9, 10, 11, 12, 16, 31 to 40, 53 and 54.
Article 26changed
Regulation (EU) No 582/2011 is amended as follows: In Article 3(1), the following subparagraph is added: ‘In order to receive an EC type-approval of a vehicle with an approved engine system with regard to emissions and vehicle repair and maintenance information, or an EC type-approval of a vehicle with regard to emissions and vehicle repair and maintenance information, the manufacturer shall also demonstrate that the requirements laid down in Article 6 and Annex II to Commission Regulation (EU) 2017/2400 ( *1 ) are met with respect to the vehicle group concerned. However, that requirement shall not apply where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of Regulation (EU) 2017/2400 for the respective vehicle group. Article 8 is amended as follows: in paragraph 1a, point (d) is replaced by the following: ‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’; in paragraph 1a, the following point is added: ‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’; Article 10 is amended as follows: in paragraph 1a, point (d) is replaced by the following: ‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’; in paragraph 1a, the following point is added: ‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’.
(1)changed
(2)added
Article 8 is amended as follows:
(a)added
in paragraph 1a, point (d) is replaced by the following:
‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’;
1.1. Vehicle datadeleted
(b)added
in paragraph 1a, the following point is added:
‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’;
(3)added
Article 10 is amended as follows:
(a)added
in paragraph 1a, point (d) is replaced by the following:
‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’;
2.1. Payload low [kg]:deleted
(b)added
in paragraph 1a, the following point is added:
‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’.
1.1 Classification of vehicles of category N
Table 1
Vehicle groups for heavy lorries
Description of elements relevant to the classification in vehicle groups | Vehicle group | Allocation of mission profile and vehicle configuration
Axle configuration | Chassis configuration | Technically permissible maximum laden mass (tons) | Long haul | Long haul EMS (1) | Regional delivery | Regional delivery EMS (1) | Urban delivery | Municipal utility | Construction>/>
4 × 2 | Rigid lorry (or tractor) (2) | > 7,4 –7,5 | 1s | R | R
Rigid lorry (or tractor) (2) | > 7,5 – 10 | 1 | R | R
Rigid lorry (or tractor) (2) | > 10 – 12 | 2 | R+T1 | R | R
Rigid lorry (or tractor) (2) | > 12 – 16 | 3 | R | R
Rigid lorry | > 16 | 4 | R+T2 | R | R | R | R
Tractor | > 16 | 5 | T+ST | T+ST+T2 | T+ST | T+ST+T2 | T+ST | T+ST
4 ×4 | Rigid lorry | > 7,5 – 16 | (6)
Rigid lorry | > 16 | (7)
Tractor | > 16 | (8)
6 ×2 | Rigid lorry | all weights | 9 | R+T2 | R+D+ST | R | R+D+ST | R | R
Tractor | all weights | 10 | T+ST | T+ST+T2 | T+ST | T+ST+T2 | T+ST
6 ×4 | Rigid lorry | all weights | 11 | R+T2 | R+D+ST | R | R+D+ST | R | R
Tractor | all weights | 12 | T+ST | T+ST+T2 | T+ST | T+ST+T2 | T+ST
6 × 6 | Rigid lorry | all weights | (13)
Tractor | all weights | (14)
8 × 2 | Rigid lorry | all weights | (15)
8 × 4 | Rigid lorry | all weights | 16 | R+T2 | R+D+ST | R | R+D+ST | R
8 ×6
8 × 8 | Rigid lorry | all weights | (17)
8 ×2
8 ×4
8 ×6
8 ×8 | Tractor | all weights | (18)
5 axles, all configurations | Rigid lorr…
1.2.added
Classification of vehicles of category M
1.2.1.added
Heavy buses
1.2.2.added
Classification of primary vehicles
Table 3
Vehicle groups for primary vehicles
Description of elements relevant to the classification in vehicle groups | Vehicle group (1) | Allocation of generic body | Vehicle sub-group | Allocation of mission profile
Number of axles | Artic-ulated | Low floor (LF) / High floor (HF) (2) | Number of decks (3) | Heavy Urban | Urban | Suburban | Interurban | Coach
2 | no | P31/32 | LF | SD | P31 SD | x | x | x | x
DD | P31 DD | x | x | x
HF | SD | P32 SD | x | x
DD | P32 DD | x | x
3 | no | P33/34 | LF | SD | P33 SD | x | x | x | x
DD | P33 DD | x | x | x
HF | SD | P34 SD | x | x
DD | P34 DD | x | x
yes | P35/36 | LF | SD | P35 SD | x | x | x | x
DD | P35 DD | x | x | x
HF | SD | P36 SD | x | x
DD | P36 DD | x | x
4 | no | P37/38 | LF | SD | P37 SD | x | x | x | x
DD | P37 DD | x | x | x
HF | SD | P38 SD | x | x
DD | P38 DD | x | x
yes | P39/40 | LF | SD | P39 SD | x | x | x | x
DD | P39 DD | x | x | x
HF | SD | P40 SD | x | x
DD | P40 DD | x | x
(1)
‘P’ indicates the primary stage of the classification; the two numbers separated by the slash indicate the numbers for vehicle groups the vehicle can be allocated in the complete or completed stage.
(2)
‘Low floor’ means vehicle codes ‘CE’, ‘CF’, ‘CG’, ‘CH’, as set out in point 3 of part C of Annex I to Regulation (EU) 2018/858.
‘High floor’ means vehicle codes ‘CA’, ‘CB’, ‘CC’, ‘CD’, as set out in point 3 of part C of Annex I to Regulation (EU) 2018/858.
(3)
‘SD’ means single d…
1.2.3.added
Classification of complete vehicles or completed vehicles
The classification of complete or completed vehicles that are heavy buses is based on the following six criteria:
(a)added
Number of axles;
(b)added
Vehicle code as set out in Annex I, part C, point 3, to Regulation (EU) 2018/858;
(c)added
Class of vehicle in accordance with paragraph 2 of UN Regulation No. 107 (
2
);
3.1.5 Engine cooling systemdeleted
(d)added
Low entry vehicle (‘yes/no’ information derived from vehicle code and type of axle) to be determined according the decision flow shown in Figure 1;
(e)added
Number of passengers in lower deck from the Certificate of Conformity as set out in Annex VIII to Commission Implementing Regulation (EU) 2020/683 (
3
) or equivalent documents in the case of individual vehicle approval;
(f)added
Height of the integrated body to be determined in accordance with Annex VIII.
Figure 1
Decision flow to determine whether a vehicle is ‘low entry’ or not:
The corresponding classification to be used is given in Tables 4, 5 and 6.
Table 4
Vehicle groups for complete vehicles and completed vehicles that are heavy buses with 2 axles
Description of elements relevant to the classification in vehicle groups | Vehicle group | Allocation of
mission profile
Number of Axles | Chassis configuration
(explanation only) | Vehicle Code (*1) | Class of vehicle (*2) | Low Entry
(Vehicle Code CE or CG only) | Passenger seats in lower deck (Vehicle Code CB or CD only) | Height of the integrated body in [mm] (Vehicles Class ‘II+III’ only)
I | I
+II
or
A | II | II
+III | III
or
B | Heavy Urban | Urban | Suburban | Interurban | Coach
2 | rigid | LF | SD | CE | x | x | x | no | — | — | 31a | x | x | x
x | x | yes | — | — | 31b1 | x | x | x
x | yes | — | — | 31b2 | x | x | x | x
DD | CF | x | x | x | — | — | — | 31c | x | x | x
open top | SD | CI | x | x | x | x | x | — | — | — | 31d | x | x | x
DD | CJ | x | x | x | x | x | — | — | — | 31e | x | x | x
HF | SD | CA | x | — | — | — | 32a | x | x
x | — | — | ≤ 3 100 | 32b | x | x
x | — | — | > 3 100 | 32c | x | x
x | — | — | — | 32d | x | x
DD | CB | x | x | x | — | ≤ 6 | — | 32e | x | x
x | x | x | — | > 6 | — | 32f | x | x
(*1)
In accordance with Regulation (EU) 2018/858.
(*2)
In accordance with paragraph 2 of UN Regulation No…
2.1.added
For heavy buses the vehicle specifications of the complete vehicle or completed vehicle including properties of the final bodywork and auxiliary units shall be reflected in the results for CO2 emissions and fuel consumption. In the case of heavy buses built in steps, more than a single manufacturer may be involved in the process of generation of input data and input information and the operation of the simulation tool. For heavy buses the CO2 emissions and fuel consumption shall be based on the following two different simulations:
(a)added
for the primary vehicle;
(b)added
for the complete vehicle or completed vehicle.
2.2.added
If a heavy bus is approved by a manufacturer as a complete vehicle, the simulations shall be performed for both the primary vehicle and the complete vehicle.
2.3.added
For the primary vehicle the input to the simulation tool covers input data regarding the engine, transmission, tyres and input information for a subset of auxiliary units (
4
). The classification into vehicle groups is performed in accordance with Table 3 based on the number of axles and the information whether the vehicle is an articulated bus or not. In the simulations for the primary vehicle the simulation tool allocates a set of four different generic bodies (high floor and low floor, single deck and double deck bodywork) and simulates the 11 mission profiles as listed in Table 3 for each vehicle group for two different loading conditions. This leads to a set of 22 results for CO2 emissions and fuel consumption for a primary heavy bus. The simulation tool produces the vehicle information file for the initial step (VIF1), which contains all necessary data to be handed over to the subsequent manufacturing step. The VIF1 comprises all non-confidential input data, the results for energy consumption (
5
) in [MJ/km], information on the primary manufacturer and the relevant hashes (
6
).
If a heavy bus is approved as a complete vehicle, only the mission profiles for the primary vehicle group related to the group of the complete vehicle as set out in Table 7 may be simulated. If the complete vehicle group changes in a subsequent manufacturing step, the primary vehicle manufacturer shall make the VIF1 with the set of 22 results available to the manufacturer responsible fo…
2.4.added
The manufacturer of the primary vehicle shall make the VIF1 available to the manufacturer responsible for the subsequent manufacturing step. Where a manufacturer of a primary vehicle provides data going beyond the primary vehicle requirements as set out in Annex III, this data does not influence the simulation results for the primary vehicle but is written into the VIF1 to be considered in later steps. For a primary vehicle the simulation tool furthermore produces a manufacturer’s records file.
2.5.added
In the case of an interim vehicle, the interim manufacturer is responsible for a sub-set of relevant input data and input information for the final bodywork (
7
). An interim manufacturer does not apply for certification of the completed vehicle. An interim manufacturer shall add or update information relevant for the completed vehicle and operate the simulation tool to produce an updated and hashed version of the vehicle information file (VIFi) (
8
). The VIFi shall be made available to the manufacturer responsible for the subsequent manufacturing step. For interim vehicles the VIFi also covers the task of documentation towards approval authorities. No simulations of CO2 emissions and/or fuel consumption are performed on interim vehicles.
2.6.added
If a manufacturer performs modifications to an interim, complete or completed vehicle, which would require updates to the input data or the input information allocated to the primary vehicle (e.g. a change of an axle or of tyres), the manufacturer performing the modification acts as a primary vehicle manufacturer with the corresponding responsibilities.
2.7.added
For a complete or completed vehicle the manufacturer shall complement and, if necessary, update the input data and input information for the final bodywork as transmitted in the VIFi from the previous manufacturing step and shall operate the simulation tool to calculate the CO2 emissions and fuel consumption. For the simulations at this stage, heavy buses are classified based on the six criteria set out in point 1.2.3 into the vehicle groups as listed in Tables 4, 5 and 6. To determine CO2 emissions and fuel consumption of complete vehicles or completed vehicles that are heavy buses the simulation tool performs the following calculation steps:
Step 1 - Selection of the primary vehicle sub-group which matches the bodywork of the complete or completed vehicle (e.g. ‘P34 DD’ for ‘34f’) and making available the corresponding results for energy consumption from the primary vehicle simulation.
Step 2 - Performing simulations to quantify the influence of the bodywork and auxiliaries of the complete vehicle or completed vehicle compared to the generic bodywork and auxiliaries, as considered in the simulations for the primary vehicle regarding energy consumption. In these simulations, generic data are used for the set of primary vehicle data, which are not part of the information transfer between different manufacturing steps as provided by the VIF (
9
).
Step 3 - Combining energy consumption results from the primary vehicle simulation as made available by step 1 with the results f…
1.1.added
The manufacturer shall set up at least the following processes:
A data management system covering sourcing, storing, handling and retrieving of the input information and input data for the simulation tool as well as handling certificates on the CO2 emissions and fuel consumption related properties of a component families, separate technical unit families and system families. The data management system shall at least:
(a)added
ensure application of correct input information and input data to specific vehicle configurations
(b)added
ensure correct calculation and application of standard values;
(c)added
verify by means of comparing cryptographic hashes that the input files of components, separate technical units, systems or if applicable their respective families, which are used for the simulation corresponds to the input data of the component, separate technical unit, system or if applicable their respective family for which the certification has been granted;
(d)added
include a protected database for storing the input data relating to the component families, separate technical unit families or system families and the corresponding certificates of the CO2 emissions and fuel consumption related properties;
(e)added
ensure correct management of the changes of specification and updates of components, separate technical units and systems;
(f)added
enable tracing of the components, separate technical units and systems after the vehicle is produced.
A data management system covering retrieving of the input information and input data and calculations by means of the simulation tool and storing of the output data. The data management system shall at least:
(a)added
ensure a correct application of cryptographic hashes;
(b)added
include a protected database for storing the output data;
Process for consulting the dedicated electronic distribution platform referred to in Article 5(2) and Article 10(1) and (2), as well as downloading and installing the latest versions of the simulation tool.
Appropriate training of staff working with the simulation tool.
2.1.added
The approval authority shall verify whether the processes set out in point 1 related to the operation of the simulation tool have been set up.
The approval authority shall also verify the following:
(a)added
the functioning of the processes set out in points 1.1.1, 1.1.2 and 1.1.3 and the application of the requirement set out in point 1.1.4;
(b)added
that the processes used during the demonstration are applied in the same manner in all the production facilities manufacturing vehicles belonging to the application case concerned;
(c)added
the completeness of the description of the data and process flows of operations related to the determination of the CO2 emissions and fuel consumption of the vehicles.
For the purpose of the second paragraph, point (a), the verification shall include determination of the CO2 emissions and fuel consumption of at least one vehicle from each production facility for which the licence has been applied for.
SECTION Iadded
1 | Name and address of vehicle manufacturer:
2 | Assembly plants for which the processes referred to in point 1 of Annex II of Regulation (EU) 2017/2400 have been set up with a view to the operation of the simulation tool:
3 | Application case covered:
4 | Name and address of the manufacturer's representative (if any)
1.1 | Data and process flow handling description (e.g. flow chart)
1.2 | Description of quality management process
1.3 | Additional quality management certificates (if any)
1.4 | Description of simulation tool data sourcing, handling and storage
1.5 | Additional documents (if any)
2. | Date: …
3. | Signature: …
Communication concerning:
— granting (1)
— extension (1)
— refusal (1)
— withdrawal (1) | Administration stamp
(1)
Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable)
of the licence to operate simulation tool with regard to Regulation (EC) No 595/2009 as implemented by Regulation (EU) 2017/2400.
Licence number:
Reason for extension: …
SECTION Iadded
0.1 | Name and address of vehicle manufacturer:
0.2 | Production facilities and/or assembly plants for which the processes referred to in point 1 of Annex II to Commission Regulation (EU) 2017/2400 (
10
) have been set up with a view to the operation of the simulation tool
0.3 | Application case covered:
1.1 | Assessment report performed by an approval authority
1.2. | Data and process flow handling description (e.g. flow chart)
1.3. | Description of quality management process
1.4. | Additional quality management certificates (if any)
1.5. | Description of simulation tool data sourcing, handling and storage
1.6 | Additional documents (if any)
2. | Approval authority responsible for carrying out the assessment
3. | Date of the assessment report
4. | Number of assessment report report
5. | Remarks (if any): see Addendum
6. | Place
7. | Date
8. | Signature
(1)added
‘parameter ID’: Unique identifier as used in the simulation tool for a specific input parameter or set of input data.
(2)added
‘type’: Data type of the parameter
string … | sequence of characters in ISO8859-1 encoding
token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date … | date and time in UTC time in the format:YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer … | value with an integral data type, no leading zeros, e.g. ‘1 800 ’
double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2 345,67 ’; for ‘double, 4’: ‘45.6780’.
(3)added
‘unit’ … physical unit of the parameter.
(4)added
‘corrected actual mass of the vehicle’ means the mass as specified under the ‘actual mass of the vehicle’ in accordance with Commission Regulation (EU) No 1230/2012 (*) with an exception for the tank(s) which shall be filled to at least 50 % of its or their capacity/ies. The liquid containing systems are filled to 100 % of the capacity specified by the manufacturer, except the liquid containing systems for waste water that must remain empty.
For medium rigid lorries, heavy rigid lorries and tractors the mass is determined without superstructure and corrected by the additional weight of the non-installed standard equipment as specified in point 4.3. The mass of a standard body, standard semi-trailer or standard trailer to simulate the complete vehicle or complete vehicle-(semi-)trailer combination are added automatically by the simulation tool. All parts that are mounted on and above the main frame are regarded as superstructure parts if they are installed only for facilitating a superstructure, independent of the necessary parts for in running order conditions.
For heavy buses that are primary vehicles ‘corrected actual mass of the vehicle’ is not applicable as the generic mass value is allocated by the simulation tool.
(5)added
‘height of the integrated body’ means the difference in ‘Z’-direction between the reference point ‘A’ of the highest point and lowest point ‘B’ of an integrated body (see Figure 1). For vehicles deviating from the standard case, the following cases are applicable (see Figure 2):
—added
For all other cases not covered by standard or special cases 1 to 4, the height of the integrated body is the difference between the highest point of the vehicle and point B. This parameter is relevant only for heavy buses.
Figure 1
Height of the integrated body – standard case
Figure 2
Height of the integrated body – special cases
(6)added
reference point ‘A’ means the highest point on the bodywork (Figure 1). Body and/or design panels, brackets for mounting e.g. HVAC systems, hatches and similar items shall not be considered.
(7)added
reference point ‘B’ means the lowest point on the lower outside edge of the bodywork (Figure 1). Brackets e.g. for axle mounting shall not be considered.
(8)added
‘vehicle length’ means the vehicle dimension in accordance with Table I of Appendix 1 of Annex I to Regulation (EU) 1230/2012. Additionally, removable load carrier devices, non-removable coupling devices and any other non-removable exterior parts which do not affect the usable space for passengers shall not be taken into account. This parameter is relevant only for heavy buses.
(9)added
‘vehicle width’ means the vehicle dimension in accordance with Table II of Appendix 1 of Annex I to Regulation (EU) 1230/2012. Deviating from these provisions and not to be considered are removable load carrier devices, non-removable coupling devices and any other non-removable exterior parts which do not affect the usable space for passengers.
(10)added
‘entrance height in non-kneeled position’ means the floor level within the first door aperture above the ground, measured at the most forward door of the vehicle when the vehicle is in non-kneeled position.
(11)added
‘fuel cell’ means an energy converter transforming chemical energy (input) into electrical energy (output) or vice versa.
(12)added
‘fuel cell vehicle’ or ‘FCV’ means a vehicle equipped with a powertrain containing exclusively fuel cell(s) and electric machine(s) as propulsion energy converter(s).
(13)added
‘fuel cell hybrid vehicle’ or ‘FCHV’ means a fuel cell vehicle equipped with a powertrain containing at least one fuel storage system and at least one rechargeable electric energy storage system as propulsion energy storage systems.
(14)added
‘pure ICE vehicle’ means a vehicle where all of the propulsion energy converters are internal combustion engines.
(15)added
‘electric machine’ or ‘EM’ means an energy converter transforming between electrical and mechanical energy.
(16)added
‘energy storage system’ means a system which stores energy and releases it in the same form as was input.
(17)added
‘propulsion energy storage system’ means an energy storage system of the powertrain which is not a peripheral device and whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
(18)added
‘category of propulsion energy storage system’ means a fuel storage system, a rechargeable electric energy storage system (REESS), or a rechargeable mechanical energy storage system.
(19)added
‘downstream’ means a position in the vehicle’s powertrain that is closer to the wheels than the actual reference position.
(20)added
‘drivetrain’ means the connected elements of the powertrain for transmission of the mechanical energy between the propulsion energy converter(s) and the wheels.
(21)added
‘energy converter’ means a system where the form of energy output is different from the form of energy input.
(22)added
‘propulsion energy converter’ means an energy converter of the powertrain which is not a peripheral device whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
6.1.17 Technical Report IDdeleted
(23)added
‘category of propulsion energy converter’ means an internal combustion engine, an electric machine, or a fuel cell.
(24)added
‘form of energy’ means electrical energy, mechanical energy, or chemical energy (including fuels).
(25)added
‘fuel storage system’ means a propulsion energy storage system that stores chemical energy as liquid or gaseous fuel.
(26)added
‘hybrid vehicle’ or ‘HV’ means a vehicle equipped with a powertrain containing at least two different categories of propulsion energy converters and at least two different categories of propulsion energy storage systems.
SECTION Ideleted
(27)added
‘hybrid electric vehicle’ or ‘HEV’ means a hybrid vehicle where one of the propulsion energy converters is an electric machine and the other one is an internal combustion engine.
SECTION IIdeleted
(28)added
‘serial HEV’ means a HEV with a powertrain architecture where the ICE powers one or more electrical energy conversion paths with no mechanical connection between the ICE and the wheels of the vehicle.
(29)added
‘internal combustion engine’ or ‘ICE’ means an energy converter with intermittent or continuous oxidation of combustible fuel transforming between chemical and mechanical energy.
(30)added
‘off-vehicle charging hybrid electric vehicle’ or ‘OVC-HEV’ means a hybrid electric vehicle that can be charged from an external source.
(31)added
‘parallel HEV’ means a HEV with a powertrain architecture where the ICE powers only a single mechanically connected path between the engine and the wheels of the vehicle.
(32)added
‘peripheral devices’ means any energy consuming, converting, storing or supplying devices, where the energy is not directly or indirectly used for the purpose of vehicle propulsion but which are essential to the operation of the powertrain.
(33)added
‘powertrain’ means the total combination in a vehicle of propulsion energy storage system(s), propulsion energy converter(s) and the drivetrain(s) providing the mechanical energy at the wheels for the purpose of vehicle propulsion, plus peripheral devices.
(1)deleted
(34)added
‘pure electric vehicle’ or ‘PEV’ means a motor vehicle pursuant to Regulation (EU) 2018/858, article 3(16), equipped with a powertrain containing exclusively electric machines as propulsion energy converters and exclusively rechargeable electric energy storage systems as propulsion energy storage systems and/or alternatively any other means for direct conductive or inductive supply of electric energy from the power network providing the propulsion energy to the motor vehicle.
(3)deleted
(35)added
‘upstream’ means a position in the vehicle’s powertrain that is further away from the wheels than the actual reference position.
(4)deleted
(36)added
‘IEPC’ means an integrated electric powertrain component in accordance with point 2(36) of Annex Xb.
(5)deleted
(37)added
‘IHPC Type 1’ means an integrated hybrid electric vehicle powertrain component Type 1 in accordance with point 2(38) of Annex Xb;
(6)deleted
(38)added
‘dynamic charging technology’ means a technology that enables the vehicle to be connected to an external electrical power supply while in motion, providing direct power to the vehicle’s propulsion and/or auxiliary systems and/or charging the batteries;
(7)deleted
(39)added
‘overhead pantograph’ means dynamic charging technology for connection and power supply with overhead contact line infrastructure on roads;
(8)deleted
(40)added
‘overhead trolley’ means dynamic charging technology with current collector poles for connection with overhead contact line infrastructure;
(41)added
‘ground rail’ means dynamic charging technology that conductively transfers the electrical energy to the vehicle through rails embedded in or on top of the road surface;
1. Spark plugsdeleted
(42)added
‘wireless’ means dynamic charging technology that inductively transfers the electrical energy to the vehicle through devices embedded in or on top of the road surface providing magnetic fields;
2. Ignition coildeleted
(43)added
‘compressed gaseous hydrogen’ means a hydrogen storage technology which stores hydrogen in gaseous form;
3. Lubricant useddeleted
(44)added
‘liquid hydrogen’ means a hydrogen storage technology which stores hydrogen in liquid form;
4. Test fuel useddeleted
(45)added
‘cryo-compressed hydrogen’ means a hydrogen storage technology which stores hydrogen at temperatures from close to liquefication up to ambient temperature and at a pressure of at least 200 bar. The hydrogen storage technology may be capable of operating at ambient temperature but its nominal capacity may only be reached close to the liquefaction temperature of hydrogen;
5. Engine-driven equipmentdeleted
(46)added
‘empty hydrogen tank condition’ means the condition of a hydrogen tank from which it is still possible to reach a full tank in a single refuelling event without venting and which meets any of the following conditions:
(a)added
below which an indication to the driver ‘empty’ or ‘almost empty’ or similar appears;
(b)added
below which a significantly limited performance is provided by the hydrogen energy conversion system;
(47)added
‘off-vehicle charging hybrid vehicle’ or ‘OVC-HV’ means a hybrid vehicle that can be charged from an external source;
(48)added
‘off-vehicle charging fuel cell hybrid vehicle’ or ‘OVC-FCHV’ means a fuel cell hybrid vehicle that can be charged from an external source;
(49)added
‘driver-selectable mode’ means a distinct driver-selectable condition which could affect emissions, or fuel and/or energy consumption;
(50)added
‘predominant mode’ means a single driver-selectable mode that is always selected when the vehicle is switched on, regardless of the driver-selectable mode in operation when the vehicle was previously shut down, which meets the following conditions:
(a)added
it cannot be redefined to another mode;
(b)added
it can only be switched to another driver-selectable mode by an intentional action of the driver after the vehicle is switched on;
(51)added
‘battery-only predominant mode’ means a predominant mode where an OVC-HV is operating with the propulsion energy being provided exclusively by the REESS.
1. General provisionsdeleted
3. Set of input parameterschanged
4. Testrun to be performeddeleted
—added
Table 1
Input parameters ‘Vehicle/General’
Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle)
Manufacturer | P235 | Token | [-] | X | X | X | X
Manufacturer Address | P252 | Token | [-] | X | X | X | X
Model_CommercialName | P236 | Token | [-] | X | X | X | X
VIN | P238 | Token | [-] | X | X | X | X
Date | P239 | Date Time | [-] | Date and time when input information and input data is created | X | X | X | X
Legislative Category | P251 | String | [-] | Allowed values: ‘N2’, ‘N3’,‘M3’ | X | X | X | X
ChassisConfiguration | P036 | String | [-] | Allowed values: ‘Rigid Lorry’, ‘Tractor’, ‘Van’, ‘Bus’ | X | X | X
AxleConfiguration | P037 | String | [-] | Allowed values: ‘4 × 2’, ‘4 × 2F’, ‘6 × 2’, ‘6 × 4’, ‘8 × 2’, ‘8 × 4’where ‘4 × 2F’ refers to 4 × 2 vehicles with a driven front axle | X | X | X
Articulated | P281 | boolean | In accordance with Article 3, point (37) | X
CorrectedActualMass | P038 | Int | [kg] | In accordance with ‘Corrected actual mass of the vehicle’ as specified in point 2(4) | X | X | X
TechnicalPermissibleMaximumLadenMass | P041 | int | [kg] | In accordance with Article 2, point (7) of Regulation (EU) No 1230/2012 | X | X | X | X
IdlingSpeed | P198 | int | [1/min] | In accordance with point 7.1
►M4
For PEV and FCHV no input is required ◄ | X | X | X
RetarderType | P052 | string | [-] | ►M4
Allowed values: ‘None’, ‘Losses…
4.1 The vehicle mass used as input for the simulation tool shall be the corrected actual mass of the vehicle.
4.2 If not all the standard equipment is installed, the manufacturer shall add the mass of the following construction elements to the corrected actual mass of the vehicle:
(a)added
Front underrun protection in accordance with Regulation (EU) 2019/2144 (**) of the European Parliament and of the Council
(b)added
Rear underrun protection in accordance with Regulation (EU) 2019/2144
1. Fandeleted
(c)added
Lateral protection in accordance with Regulation (EU) 2019/2144
(d)added
Fifth wheel in accordance with Regulation (EU) 2019/2144
4.3 The mass of the construction elements referred to in point 4.2 shall be the following:
For vehicles of groups 1s, 1, 2 and 3 as set out in Annex I, Table 1, and for vehicle groups 51 and 53 as set out in Annex I, Table 2.
Front underride protection | 45 kg
Rear underride protection | 40 kg
Lateral protection | 8,5 kg/m × wheel base [m] – 2,5 kg
For vehicles of groups 4, 5, 9 to 12 and 16 as set out in Annex I, Table 1.
Front under-ride protection | 50 kg
Rear under-ride protection | 45 kg
Lateral protection | 14 kg/m × wheel base [m] – 17 kg
Fifth wheel | 210 kg
Appendix 6deleted
In the case of vehicles equipped with: a hydraulically driven axles, the axle shall be treated as a non-drivable one and the manufacturer shall not take it into consideration for establishing an axle configuration of a vehicle; a mechanically driven axles, the axle shall be treated as a drivable one and the manufacturer shall take it into consideration for establishing an axle configuration of a vehicle;
2 Numberingdeleted
(a)added
a hydraulically driven axles, the axle shall be treated as a non-drivable one and the manufacturer shall not take it into consideration for establishing an axle configuration of a vehicle;
(b)added
a mechanically driven axles, the axle shall be treated as a drivable one and the manufacturer shall take it into consideration for establishing an axle configuration of a vehicle;
Introductiondeleted
For the highest 50 % of the gears (e.g. for gears 7 to 12 of a 12-gear transmission) the vehicle manufacturer may declare a gear dependent maximum engine torque limit which is not higher than 95 % of the maximum engine torque.
(1)deleted
6.2 Gear disablingadded
Either for the highest gear only or for both of the highest two gears (e.g. gear 5 and 6 for a 6-gear transmission) the vehicle manufacturer may declare a complete disabling of gears by providing 0 Nm as gear specific torque limit in the input to the simulation tool. Declaring such gear disabling only for the second highest gear is not allowed.
(3)deleted
Gear dependent engine torque limits in accordance with point 6.1 and gear disabling in accordance with point 6.2 are subject to verification in the verification testing procedure (VTP) as laid out in Annex Xa, point 6.1.1.1 c).
Set of input parametersdeleted
Appendix 8deleted
7.1.added
The engine idling speed has to be declared for each individual vehicle with an ICE. This declared vehicle engine idling shall be equal or higher than specified in the engine input data approval.
(1)added
Crest coasting
Approaching a crest the vehicle velocity is reduced before the point where the vehicle starts accelerating by gravity alone compared to the set speed of the cruise control so that the braking during the following downhill phase can be reduced.
(2)added
Acceleration without engine power
During downhill driving with a low vehicle velocity and a high negative slope the vehicle acceleration is performed without any engine power usage so that the downhill braking can be reduced.
(3)added
Dip coasting
During downhill driving when the vehicle is braking at the overspeed velocity, PCC increases the overspeed for a short period of time to end the downhill event with a higher vehicle velocity. Overspeed is a higher vehicle speed than the set speed of the cruise control system.
A PCC system can be declared as input to the simulation tool if either the functionalities set out in points (1) and (2) or points (1), (2) and (3) are covered.
8.2 The eleven combinations of the advanced driver assistance systems as set out in Table 12 are input parameters into the simulation tool. Combinations 2 to 11 shall not be declared for SMT transmissions. Combinations No 3, 6, 9 and 11 shall not be declared in the case of APT transmissions.
Table 12
Combinations of advanced driver assistance systems as input parameters into the simulation tool
Combination no | Engine stop-start during vehicle stops | Eco-roll without engine stop-start | Eco-roll with engine stop-start | Predictive cruise control
1 | yes | no | no | no
2 | no | yes | no | no
3 | no | no | yes | no
4 | no | no | no | yes
5 | yes | yes | no | no
6 | yes | no | yes | no
7 | yes | no | no | yes
8 | no | yes | no | yes
9 | no | no | yes | yes
10 | yes | yes | no | yes
11 | yes | no | yes | yes
8.3 Any advanced driver assistance system declared in the input into the simulation tool shall by default be set to fuel economy mode after each key-off/key-on cycle.
8.4 If an advanced driver assistance system is declared in the i…
4. Torque converter (TC)deleted
9.1.added
For vehicles of chassis configuration ‘van’ the cargo volume shall be calculated by the following equation:
where the dimensions shall be determined in accordance with Table 13 and Figure 3.
Table 13
Definitions related to cargo volume for medium lorries of type van
Formula symbol | Dimension | Definition
LC,floor | Cargo length at floor | — longitudinal distance from the most rearward point of the last seating row or the partition wall to the foremost point of the closed rear compartment projected to the zero Y-plane
— measured at the height of the cargo floor surface
LC | Cargo length | — longitudinal distance from the X-plane tangent to the most rearward point on the seatback including head restraints of the last seating row or the partition wall to the foremost X-plane tangent to the closed rear compartment i.e. the tailgate or rear doors or any other limiting surface
— measured at the height of the most rearward point of the last seating row or the partition wall
WC,max | Maximum cargo width | — maximum lateral distance of the cargo compartment
— measured between the cargo floor and 70 mm above the floor
— measurement excludes the transitional arc, local protrusions, depressions or pockets if present
WC,wheelhouse | Cargo width at wheelhouse | — minimum lateral distance between the limiting interferences (pass-through) of the wheelhouses
— measured between the cargo floor and 70 mm above the floor
— measurement excludes the transitional arc…
The following provisions shall apply only in the case of HEV, FCHV and PEV.
The configuration of the vehicle’s powertrain shall be determined in accordance with the following definitions:
In the case of a HEV:
(a)added
‘P’ in the case of a parallel HEV
(b)added
‘S’ in the case of a serial HEV
(c)added
‘S-IEPC’ in the case an IEPC component is present in the vehicle
(d)added
‘IHPC Type 1’ in the case the parameter ‘IHPCType’ of the electric machine component is set to ‘IHPC Type 1’
In the case of a PEV:
(a)added
‘E’ in the case an EM component is present in the vehicle
(b)added
‘E-IEPC’ in the case an IEPC component is present in the vehicle
In the case of a FCHV:
(a)added
‘F’ in the case an EM component is present in the vehicle
(b)added
‘F-IEPC’ in the case an IEPC component is present in the vehicle
Where the configuration of the vehicle’s powertrain in accordance with point 10.1.1 is ‘P’, ‘S’, ‘F’ or ‘E’, the position of the EM installed in the vehicle’s powertrain shall be determined in accordance with the definitions set out in Table 14.
Table 14
Possible positions of EMs in the vehicle’s powertrain
Position index of EM | Powertrain configuration in accordance with point 10.1.1 | Transmission type in accordance with Table 1 in Appendix 12 of Annex VI | Definition / Requirements (1) | Further explanations
1 | P | AMT, APT-S, APT-P | Connected to the powertrain upstream of the clutch (in the case of AMT) or upstream of the torque converter input shaft (in the case of APT-S or APT-P).
The EM is connected to the crankshaft of the ICE directly or via a mechanical connection type (e.g. belt). | Distinction of P0: EMs which can as a matter of principle not contribute to the propulsion of the vehicle (i.e. alternators) are handled in the input to auxiliary systems (see Table 3 of this Annex for lorries, Table 3a of this Annex for buses and Annex IX).
However, EMs at this position which can in principle contribute to the propulsion of the vehicle but for which the declared maximum torque in accordance with Table 9 of this Annex is set to zero shall be declared as ‘P1’.
2 | ►M4
E, S, F ◄ | AMT | The electric machine is connected to the powertrain downstream of the clutch and upstream of the transmission input shaft.
2 | E, S | AMT, APT-N, APT-S, APT-P | The electric machi…
The input value for the powertrain architecture ID required in accordance with Table 7 shall be determined based on the powertrain configuration in accordance with point 10.1.1 and the position of the EM in the vehicle’s powertrain in accordance with point 10.1.2 (if applicable) from the valid combinations of inputs into the simulation tool listed in Table 15.
In the case of the powertrain configuration in accordance with point 10.1.1 being ‘IHPC Type 1’ the following provisions shall apply:
(a)added
The powertrain architecture ID ‘P2’ shall be declared in accordance with Table 7 and the powertrain component data as indicated in Table 15 for ‘P2’ shall be the input to the simulation tool with separate component data for the EM and the transmission determined in accordance with point 4.4.3 of Annex Xb.
(b)added
The component data for the EM in accordance with subpoint (a) shall be provided to the simulation tool with the parameter ‘PowertrainPosition’ in accordance with Table 8 set to ‘2’.
Table 15
Valid inputs of powertrain architecture into the simulation tool
Powertrain type | Powertrain configuration | Architecture ID for VECTO input | Powertrain component present in vehicle | Comments
ICE | EM position GEN | EM position 1 | EM position 2 | transmission | EM position 3 | axle | EM position 4
PEV | E | E2 | no | no | no | yes | yes | no | yes | no
E3 | no | no | no | no | no | yes | yes | no
E4 | no | no | no | no | no | no | no | yes
IEPC | E-IEPC | no | no | no | no | no | no | (1) | no
HEV | P | P1 | yes | no | yes | no | yes | no | yes | no
P2 | yes | no | no | yes | yes | no | yes | no | (2)
P2.5 | yes | no | no | yes | yes | no | yes | no | (3)
P3 | yes | no | no | no | yes | yes | yes | no | (4)
P4 | yes | no | no | no | yes | no | yes | yes
S | S2 | yes | yes | no | yes | yes | no | yes | no
S3 | yes | yes | no | no | no | yes | yes | no
S4 | yes | yes | no | no | no | no | no | yes
S-IEPC | yes | yes | no | no | no | no | (1) | no
▼M4
FCHV | F | F2 | no | no | no | yes | yes | no | yes | no
F3 | no | no | no | no | no | yes | yes | no
F4 | no | no | no | no | no | no | no | yes
F-IEPC | no | no | no | no | no | no | (1) | no
(1)
‘Yes’ (i.e. axle component present) only in the case that both parameters ‘DifferentialIncluded’ and ‘DesignTypeWheelMotor’ are set to ‘false…
In case the vehicle is equipped with two powertrains where each powertrain is propelling different wheel axles of the vehicle and where these different powertrains can under no circumstances be mechanically connected, the vehicle manufacturer shall declare a second powertrain ID defined in accordance with point 10.1.3. Additionally, the two powertrains shall share the same REESS and separate electrical to mechanical energy converters.
In this regard hydraulically driven axles shall, in accordance with point 5, second subparagraph, point (a) of this Annex, be treated as non-driven axles and shall thus not be counted as a mechanically independent powertrain.
Only powertrains of configuration S, S-IEPC, F, F-IEPC and E, in accordance with point 10.1.1, shall be allowed to be declared in case of presence of a second mechanically independent powertrain. Furthermore, only the combinations of architecture IDs for the first and second powertrain indicated with ‘yes’ in Table 15a may be declared.
Table 15a
Valid inputs of powertrain architecture into the simulation tool
Architecture
ID
ArchitectureIDPwt2 | E2 | E3 | E4 | E-IEPC | S2 | S3 | S4 | S-IEPC | F2 | F3 | F4 | F-IEPC
E2 | yes | yes | yes | yes | no | no | no | no | no | no | no | no
E3 | yes | yes | yes | yes | no | no | no | no | no | no | no | no
E4 | yes | yes | yes | yes | no | no | no | no | no | no | no | no
E-IEPC | yes | yes | yes | yes | no | no | no | no | no | no | no | no
S2 | no | no | no | no | yes | yes | yes…
The vehicle manufacturer may declare limitations of the total propulsion torque of the whole powertrain referring to the transmission input shaft for a parallel HEV in order to restrict the boosting capabilities of the vehicle.
The declaration of such limitations is allowed only in the case that the powertrain configuration in accordance with point 10.1.1 is ‘P’ or ‘IHPC Type 1’.
The limitations are declared as additional torque allowed on top of the ICE full load curve dependent on the rotational speed of the transmission input shaft. Linear interpolation is performed in the simulation tool to determine the applicable additional torque between the declared values at two specific rotational speeds. In the rotational speed range from 0 to engine idling speed (in accordance with point 7.1) the full load torque available from the ICE equals only the ICE full load torque at engine idling speed due to the modelling of the clutch behaviour during vehicle starts.
Where such a limitation is declared, values for the additional torque shall be declared at least at a rotational speed of 0 and at the maximum rotational speed of the ICE full load curve. Any arbitrary number of values may be declared in between the range of zero and the maximum rotational speed of the ICE full load curve. Declared values lower than zero shall not be allowed for the additional torque.
The vehicle manufacturer may declare such limitations which match exactly the ICE full load curve by declaring values of 0 …
Where the vehicle is equipped with an engine stop-start functionality in accordance with point 8.1.1 considering the boundary conditions in point 8.4, the input parameter P271 in accordance with Table 6 shall be set to true.
11.1.added
Results of the simulation tool may be transferred to other vehicles as provided for in Article 9(6), provided that all of the following conditions are met:
(a)added
input data and input information is completely identical with exception of VIN (P238) and Date element (P239). In the case of simulations for primary heavy buses, additional input data and input information relevant for the interim vehicle and available already at the initial stage may differ, but special measures have to be taken in this case;
(b)added
the version of the simulation tool is identical.
11.2.added
For the transfer of results the following result files shall be considered:
(a)added
medium and heavy lorries: manufacturer’s records file and customer information file
(b)added
primary heavy buses: manufacturer’s records file and vehicle information file
(c)added
complete or completed heavy buses: manufacturer’s records file, customer information file and vehicle information file
11.3.added
To carry out the transfer of results the files as mentioned in 10.2. shall be modified by replacing the data elements as set out in the subpoints with updated information. Modifications are allowed only for data elements related to the current stage of completion.
(a)added
VIN (Annex IV, Part I, point 1.1.3)
(b)added
Date when the output file was created (Annex IV, Part I, point 3.2)
(a)added
VIN (Annex IV, Part II, point 1.1.1)
(b)added
Date when the output file was created (Annex IV, Part II, point 3.2)
11.3.3.1.added
In the case of a primary heavy bus:
(a)added
VIN (Annex IV, Part III, point 1.1)
(b)added
Date when the output file was created (Annex IV, Part III, point 1.3.2)
11.3.3.2.added
Where a manufacturer of a primary heavy bus provides data going beyond the primary vehicle requirements and which differs between original vehicle and transferred vehicle, the related data elements in the vehicle information file shall be updated accordingly.
11.3.3.3.added
In the case of a complete or completed heavy bus:
(a)added
VIN (Annex IV, Part III, point 2.1)
(b)added
Date when the output file was created (Annex IV, Part III, point 2.2.2)
11.3.4 | After the modifications as described above the signature elements as set out below shall be updated.
11.3.4.1. Lorries:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.6. and 3.7
(b)
Customer information file: Annex IV, Part II, points 3.3 and 3.4
11.3.4.2. Primary heavy buses:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.3 and 3.4
(b)
Vehicle information file: Annex IV, Part III, points 1.4.1 and 1.4.2
11.3.4.3. Primary heavy buses where additionally input data for the interim vehicle has been provided:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.3 and 3.4
(b)
Vehicle information file: Annex IV, Part III, points 1.4.1, 1.4.2 and 2.3.1
11.3.4.4. Complete or completed heavy buses
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.6 and 3.7
(b)
Vehicle information file: Annex IV, Part III, point 2.3.1
11.4.added
Where CO2 emissions and fuel consumption cannot be determined for the original vehicle due to a malfunction of the simulation tool, the same measures shall apply to the vehicles with transferred results.
11.5.added
If the approach to transfer results to other vehicles as laid down in this paragraph is applied by a manufacturer, the related process shall be demonstrated to the approval authority as part of granting the process licence.
For fuel storage systems containing hydrogen the usable capacity shall be determined.
The usable capacity shall be calculated based on the following equation:
where:
musable | usable capacity [kg]
VCHSS | volume of the compressed hydrogen storage technology [l]
pmin,rel | relative pressure corresponding to empty hydrogen tank condition [MPa]
ρ15°C, NWP | density of the compressed gaseous hydrogen at 15 °C and at nominal working pressure (NWP) as defined in point 2.17. of UN Regulation No 134 [g/l]
This density value shall be determined from Table 16 by linear interpolation.
ρ15°C, pmin,rel | density of the compressed gaseous hydrogen at 15 °C and at pmin,rel [g/l]
This density value shall be determined from Table 16 by linear interpolation.
Table 16
Density of compressed hydrogen at 15 °C [g/l]
Temperature (°C) | Pressure (MPa)
0,5 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 35 | 70
15 | 0,5 | 0,9 | 1,7 | 2,6 | 3,4 | 4,2 | 4,9 | 5,7 | 6,5 | 7,3 | 8,0 | 24,0 | 40,2
The usable capacity shall be calculated based on the following equation:
where:
musable | usable capacity [kg]
VLHSS | volume of the liquid hydrogen storage technology [l]
ρfull ref | density of the liquid hydrogen corresponding to full hydrogen tank condition [g/l], defined by the following operational conditions:
(a)
the vehicle is operated until the empty hydrogen tank condition is reached.
(b)
the refilling starts immediately afterwards.
(c)
with regard to the state of the hydrogen as provided by the hydrogen refuelling infrastructure, reference shall be made to international standards, if available.
ρempty | density of the liquid hydrogen corresponding to the empty hydrogen tank condition [g/l]
The calculation model of the densities shall be disclosed to the approval authority on request.
SECTION Ideleted
Appendix 2deleted
0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
Appendix 3deleted
0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
1. Method of measurementdeleted
Appendix 4deleted
0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
1. Method of measurementdeleted
Appendix 5deleted
0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
1. Method of measurementdeleted
1. Generaldeleted
1.1 Special casesdeleted
1. Markingsdeleted
2. Numberingdeleted
Appendix 8deleted
Appendix 9deleted
Generic torque ratiodeleted
Appendix 10deleted
Appendix 11deleted
Introductiondeleted
(1)deleted
(3)deleted
Set of input parametersdeleted
SECTION Ideleted
SECTION IIdeleted
Appendix 2deleted
0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
Appendix 3deleted
Appendix 4deleted
1. Markingsdeleted
2. Numbering:deleted
Introductiondeleted
(1)deleted
(3)deleted
Set of input parametersdeleted
3.4. Measurement equipmentdeleted
3.4.1. Torquedeleted
3.4.2. Vehicle speeddeleted
3.4.7. Mobile anemometerdeleted
3.7. Testing Templatedeleted
3.8. Data processingdeleted
3.10. Validity criteriadeleted
SECTION Ideleted
SECTION IIdeleted
Appendix 2deleted
0.0. GENERALdeleted
LIST OF ATTACHMENTSdeleted
1.deleted
2.deleted
3.deleted
1.deleted
2.deleted
3.deleted
4.deleted
5.deleted
1. Generaldeleted
2. Special casesdeleted
1.deleted
2.deleted
3.deleted
4.deleted
5.deleted
1.deleted
2.deleted
3.deleted
Appendix 8deleted
2 Numberingdeleted
Introductiondeleted
(1)deleted
2. Definitionschanged
For the purposes of this Annex the definitions according to UN/ECE set out in UN Regulation No. 49 Rev.06 ( 11 ) and, in addition to these, the following definitions shall apply: ‘engine CO2-family’ means a manufacturer's grouping of engines, as defined in paragraph 1 of Appendix 3; ‘CO2-parent engine’ means an engine selected from an engine CO2-family as specified in Appendix 3; ‘NCV’ means net calorific value of a fuel as specified in paragraph 3.2; ‘specific mass emissions’ means the total mass emissions divided by the total engine work over a defined period expressed in g/kWh; ‘specific fuel consumption’ means the total fuel consumption divided by the total engine work over a defined period expressed in g/kWh; ‘FCMC’ means fuel consumption mapping cycle; ‘Full load’ means the delivered engine torque/power at a certain engine speed when the engine is operated at maximum operator demand. The definitions in paragraphs 3.1.5 and 3.1.6. of Annex 4 to UN/ECE Regulation 49 Rev.06 shall not apply.
3. General requirementschanged
►M3 The calibration laboratory facilities shall comply with the requirements of either ISO/TS IATF 16949, ISO 9000 series or ISO/IEC 17025. 17025 ◄ . All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national or international standards. Engines shall be grouped into engine CO2-families defined in accordance with Appendix 3. Paragraph 4.1 explains which testruns shall be performed for the purpose of certification of one specific engine CO2-family.
The tests shall be conducted under ambient conditions meeting the following conditions over the whole testrun: The parameter fa describing the laboratory test conditions, determined in accordance with paragraph 6.1 of Annex 4 to UN/ECE Regulation 49 Rev.06, shall be within the following limits: 0,96 ≤ fa ≤ 1,04. The absolute temperature (Ta) of the engine intake air expressed in Kelvin, determined in accordance with paragraph 6.1 of Annex 4 to UN/ECE Regulation 49 Rev.06 shall be within the following limits: 283 K ≤ Ta ≤ 303 K. The atmospheric pressure expressed in kPa, determined in accordance with paragraph 6.1 of Annex 4 to UN/ECE Regulation 49 Rev.06 shall be within the following limits: 90 kPa ≤ ps ≤ 102 kPa. If tests are performed in test cells that are able to simulate barometric conditions other than those existing in the atmosphere at the specific test site, the applicable fa value shall be determined with the simulated values of atmospheric pressure by the conditioning system. The same reference value for the simulated atmospheric pressure shall be used for the intake air and exhaust path and all other relevant engine systems. The actual value of the simulated atmospheric pressure for the intake air and exhaust path and all other relevant engine systems shall be within the limits specified in subpoint (3). In cases where the ambient pressure in the atmosphere at the specific test site exceeds the upper limit of 102 kPa, tests in accordance with this Annex may still be performed. In this case tests shall be performed with the specific ambient air pressure in the atmosphere. In cases where the test cell has the ability to control temperature, pressure and/or humidity of engine intake air independent of the atmospheric conditions the same settings for those parameters shall be used for all testruns performed for the purpose of certification of one specific engine CO2-family defined in accordance with Appendix 3 to this Annex.
3.1.2 Engine installationchanged
The test engine shall be installed in accordance with paragraphs 6.3 to 6.6 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. If auxiliaries/equipment necessary for operating the engine system are not installed as required in accordance with paragraph 6.3 of Annex 4 to UN/ECE UN Regulation 49 Rev.06, No. 49, all measured engine torque values shall be corrected for the power required for driving these components for the purpose of this Annex in accordance with paragraph 6.3 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. The No. 49. Such corrections of engine torque and power values shall be performed if the sum of absolute values of additional or missing engine torque required for driving these engine components in a specific engine operation point exceeds the torque tolerances defined in accordance with paragraph 4.3.5.5 (1) subparagraph (b). Where such an engine component is operated in an intermittent manner, the engine torque values for driving the respective component shall be determined as average value over an appropriate period, reflecting the actual operating mode based on good engineering judgement and in agreement with the approval authority. For the purpose of determining whether such a correction is required or not, as well as for deriving the actual values to perform the correction, the power consumption of the following engine components components, resulting in the engine torque required for driving these engine components components, shall be determined in accordance with Appendix 5 to of this Annex: fan electrically powered auxiliaries/equipment necessary for operating the engine system
3.1.3 Crankcase emissionschanged
In the case of a closed crankcase, the manufacturer shall ensure that the engine's ventilation system does not permit the emission of any crankcase gases into the atmosphere. ►M3 If the crankcase is of an open type, the emissions shall be measured and added to the tailpipe emissions, following the provisions set out in paragraph 6.10. 6.10 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. ◄
During all testruns the charge air cooling system used on the test bed shall be operated under conditions which are representative for in-vehicle application at reference ambient conditions. The reference ambient conditions are defined as 293 K for air temperature and 101,3 kPa for pressure. The laboratory charge air cooling for tests according to this regulation Regulation should comply with the provisions specified in paragraph 6.2 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49.
3.2 Fuelschanged
The respective reference fuel for the engine systems under test shall be selected from the fuel types listed in Table 1. 1 and shall be the same as the reference fuel used for the EC type-approval in accordance with Regulation (EU) No 582/2011. The fuel properties of the reference fuels listed in Table 1 shall be those specified in Annex IX to Commission Regulation (EU) No 582/2011. 582/2011 and for hydrogen in Annex 5 of UN Regulation No 49. To ensure that the same fuel is used for all testruns performed for the purpose of certification of one specific engine CO2-family no refill of the tank or switch to another tank supplying the engine system shall occur. Exceptionally a refill or switch may be allowed if it can be ensured that the replacement fuel has exactly the same properties as the fuel used before (same production batch). The NCV for the fuel used shall be determined by two separate measurements in accordance with the respective standards for each fuel type defined in Table 1. The two separate measurements shall be performed by two different labs independent from the manufacturer applying for certification. The lab performing the measurements shall comply with the requirements of ISO/IEC 17025. The approval authority shall ensure that the fuel sample used for determination of the NCV is taken from the batch of fuel used for all testruns. If the two separate values for the NCV are deviating by more than 440 Joule per gram fuel, the values determined shall be void and the measurement campaign shall be repeated. The mean value of the two separate NCV that are not deviating by more than 440 Joule per gram fuel shall be documented in MJ/kg rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06. For gas and hydrogen fuels the standards for determining the NCV according to Table 1 contain the calculation of the calorific value based on the fuel composition. The gas or hydrogen fuel composition for determining the NCV shall be taken from the analysis of the reference gas fuel batch used for the certification tests. For the determination of the gas or hydrogen fuel composition used for determining the NCV only one single analysis by a lab independent from the manufacturer applying for certification shall be performed. For gas or hydrogen fuels the NCV shall be determined based on this single analysis instead of a mean value of two separate measurements. For gas and hydrogen fuels, switches between fuel supply tanks of different production batches are allowed exceptionally; in exceptionally. In that case, the NCV of each used fuel batch should shall be calculated and the highest value should of those values shall be documented. Table 1 Reference fuels for testing Fuel type / engine type | Reference fuel type | Standard used for determination of NCV Diesel / CI | ►M4 B7 or B100 ◄ | at least ASTM D240 or DIN 59100-1 (ASTM D4809 is recommended) Ethanol / CI | ED95 | at least ASTM D240 or DIN 59100-1 (ASTM D4809 is recommended) Petrol / PI | E10 | at least ASTM D240 or DIN 59100-1 (ASTM D4809 is recommended) Ethanol / PI | E85 | at least ASTM D240 or DIN 59100-1 (ASTM D4809 is recommended) LPG / PI | LPG Fuel B | ASTM 3588 or DIN 51612 ▼M1 ►M3 Natural gas / PI or Natural Gas / CI ◄ | G25 or GR | ISO 6976 or ASTM 3588 ▼B ▼M4 Hydrogen / PI or Hydrogen / CI | Hydrogen | ISO 6976 or ASTM 3588
3.3 Lubricantschanged
►M3 The lubricating oil for all testruns test runs performed in accordance with this Annex shall be a commercially available oil with unrestricted manufacturer approval under normal in-service conditions as defined in paragraph 4.2 of Annex 8 to UN/ECE UN Regulation 49 Rev.06. No. 49. ◄ Lubricants for which the usage is restricted to certain special operation conditions of the engine system or having an unusually short oil change interval shall not be used for the purpose of testruns in accordance with this Annex. The commercially available oil shall not be modified by any means and no additives shall be added. All testruns performed for the purpose of certification of the CO2 emissions and fuel consumption related properties of one specific engine CO2-family shall be performed with the same type of lubricating oil.
The measurement equipment shall meet the requirements of paragraph 9 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. Notwithstanding the requirements defined in paragraph 9 of Annex 4 to UN/ECE UN Regulation 49 Rev.06, No. 49, the measurement systems listed in Table 2 shall meet the limits defined in Table 2. Table 2 Requirements of measurement systems Linearity Measurement system | Intercept | xmin × (a1 – 1) + a0 | | Slope a1 | Standard error of estimate SEE | Coefficient of determination r2 | Accuracy (1) | Rise time (2) Engine speed | ≤ 0,2 % max calibration (3) | 0,999 - 1,001 | ≤ 0,1 % max calibration (3) | ≥ 0,9985 | 0,2 % of reading or 0,1 % of max. calibration (3) of speed whichever is larger | ≤ 1 s Engine torque | ≤ 0,5 % max calibration (3) | 0,995 - 1,005 | ≤ 0,5 % max calibration (3) | ≥ 0,995 | 0,6 % of reading or 0,3 % of max. calibration (3) of torque whichever is larger | ≤ 1 s Fuel mass flow for liquid fuels | ≤ 0,5 % max calibration (3) | 0,995 - 1,005 | ≤ 0,5 % max calibration (3) | ≥ 0,995 | 0,6 % of reading or 0,3 % of max. calibration (3) of flow whichever is larger | ≤ 2 s ▼M4 Fuel mass flow for gaseous and hydrogen fuels | ≤ 1 % max calibration (3) calibration(3) | 0,99 - – 1,01 | ≤ 1 % max calibration (3) | ≥ 0,995 | 1 % of reading or 0,5 % of max. calibration (3) of flow whichever is larger | ≤ 2 s ▼B Electrical Power | ≤ 1 % max calibration (3) | 0,98 - 1,02 | ≤ 2 % max calibration (3) | ≥ 0,990 | n.a. | ≤ 1 s Current | ≤ 1 % max calibration (3) | 0,98 - 1,02 | ≤ 2 % max calibration (3) | ≥ 0,990 | n.a. | ≤ 1 s Voltage | ≤ 1 % max calibration (3) | 0,98 - 1,02 | ≤ 2 % max calibration (3) | ≥ 0,990 | n.a. | ≤ 1 s ▼M3 Temperature relevant for WHR system | ≤ 1,5 % max calibration (3) | 0,98 - 1,02 | ≤ 2 % max calibration (3) | ≥ 0,980 | n.a. | ≤ 10 s Pressure relevant for WHR system | ≤ 1,5 % max calibration(3) | 0,98 - 1,02 | ≤ 2 % max calibration (3) | ≥ 0,980 | n.a. | ≤ 3 s Electrical power relevant for WHR system | ≤ 2 % max calibration (3) | 0,97 - 1,03 | ≤ 4 % max calibration (3) | ≥ 0,980 | n.a. | ≤ 1 s Mechanical power relevant for WHR system | ≤ 1 % max calibration (3) | 0,995 - 1,005 | ≤ 1,0 % max calibration (3) | ≥ 0,99 | 1,0 % of reading or 0,5 % of max. calibration (3) of power whichever is larger | ≤ 1 s (1) ‘Accuracy’ means the deviation of the analyzer reading from a reference value which is traceable to a national or international standard. (2) ‘Rise time’ means the difference in time between the 10 percent and 90 percent response of the final analyzer reading (t90 – t10). (3) The ‘max calibration’ values shall be 1,1 times the maximum predicted value expected during all testruns for the respective measurement system. ‘xmin’, used for calculation In the case of dual-fuel engines, the intercept ‘max calibration’ value in Table 2, shall be 0,9 times the minimum predicted value expected during all testruns applicable for the respective measurement system. The signal delivery rate of the measurement systems listed in Table 2, except system for the fuel mass flow measurement system, for both liquid and gaseous fuels shall be at least 5 Hz (≥ 10 Hz recommended). The signal delivery rate of defined in accordance with the fuel mass flow measurement system shall be at least 2 Hz. All measurement data shall be recorded with a sample rate of at least 5 Hz (≥ 10 Hz recommended). following provisions:
A verification of the demanded requirements defined in Table 2 shall be performed for each measurement system. At least 10 reference values between xmin and the ‘max calibration’ value defined in accordance with paragraph 3.5 shall be introduced to the measurement system and the response of the measurement system shall be recorded as measured value. For the linearity verification the measured values shall be compared to the reference values by using a least squares linear regression in accordance with paragraph A.3.2 of Appendix 3 to Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ .
4. Testing procedurechanged
All measurement data shall be determined in accordance with Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , unless stated otherwise in this Annex.
4.3.1 Engine full load curvechanged
The engine full load curve shall be recorded in accordance with paragraphs 7.4.1. to 7.4.5. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ .
4.3.2 Engine motoring curvechanged
The recording of the engine motoring curve in accordance with this paragraph shall be omitted for all other engines except the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3. In accordance with paragraph 6.1.3 the engine motoring curve recorded for the CO2-parent engine of the engine CO2-family shall also be applicable to all engines within the same engine CO2-family. In the case that upon request of the manufacturer the provisions defined in Article 15(5) of this Regulation are applied, the recording of the engine motoring curve shall be performed additionally for that specific engine. The engine motoring curve shall be recorded in accordance with option (b) in paragraph 7.4.7. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . This test shall determine the negative torque required to motor the engine between maximum and minimum mapping speed with minimum operator demand. The test shall be continued directly after the full load curve mapping according to paragraph 4.3.1. At the request of the manufacturer, the motoring curve may be recorded separately. In this case the engine oil temperature at the end of the full load curve testrun performed in accordance with paragraph 4.3.1 shall be recorded and the manufacturer shall prove to the satisfaction of the an approval authority, that the engine oil temperature at the starting point of the motoring curve meets the aforementioned temperature within ± 2 K. At the start of the testrun for the engine motoring curve the engine shall be operated with minimum operator demand at maximum mapping speed defined in paragraph 7.4.3. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . As soon as the motoring torque value has stabilized within ± 5 % of its mean value for at least 10 seconds, the data recording shall start and the engine speed shall be decreased at an average rate of 8 ± 1 min– 1/s from maximum to minimum mapping speed, which are defined in paragraph 7.4.3. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ .
4.3.3 WHTC testchanged
The WHTC test shall be performed in accordance with Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. The weighted emission test results shall meet the applicable limits defined in Regulation (EC) No 595/2009. Dual-fuel engines shall meet the applicable limits in accordance with Annex XVIII, point 5, to Regulation (EU) No 582/2011. The engine full load curve recorded in accordance with paragraph 4.3.1 shall be used for the denormalization denormalisation of the reference cycle and all calculations of reference values performed in accordance with paragraphs 7.4.6, 7.4.7 and 7.4.8 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49.
In addition to the provisions defined in Annex 4 to UN/ECE UN Regulation 49 Rev.06 No 49, the actual fuel mass flow consumed by the engine in accordance with paragraph 3.4 and the data referred to in point 4.3.5.3(5)(a) in application to the WHTC test shall be recorded.
4.3.4 WHSC testchanged
The WHSC test shall be performed in accordance with Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. The emission test results shall meet the applicable limits defined in Regulation (EC) No 595/2009. Dual-fuel engines shall meet the applicable limits in accordance with Annex XVIII, point 5, to Regulation (EU) No 582/2011. The engine full load curve recorded in accordance with paragraph point 4.3.1 shall be used for the denormalization denormalisation of the reference cycle and all calculations of reference values performed in accordance with paragraphs 7.4.6, 7.4.7 and 7.4.8 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49.
In addition to the provisions defined in Annex 4 to UN/ECE UN Regulation 49 Rev.06 No 49, the actual fuel mass flow consumed by the engine in accordance with paragraph 3.4 and the data referred to in point 4.3.5.3(5)(a) in application to the WHSC test shall be recorded.
If an after-treatment regeneration event occurs during the FCMC for engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis defined in accordance with paragraph 6.6 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , all measurements at that engine speed mode shall be void. The regeneration event shall be completed and afterwards the procedure shall be continued as described in paragraph 4.3.5.1.1. If an unexpected interruption, malfunction or error occurs during the FCMC, all measurements at that engine speed mode shall be void and one of the following options how to continue shall be chosen by the manufacturer: the procedure shall be continued as described in paragraph 4.3.5.1.1 the whole FCMC shall be repeated in accordance with paragraphs 4.3.5.4 and 4.3.5.5
The engine shall be started and warmed up in accordance with paragraph 7.4.1. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . After warm-up, the engine shall be preconditioned by operating the engine for 20 minutes at mode 9, as defined in Table 1 of paragraph 7.2.2. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . The engine full load curve recorded in accordance with paragraph 4.3.1 shall be used for the denormalization of the reference values of mode 9 performed in accordance with paragraphs 7.4.6, 7.4.7 and 7.4.8 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . Directly after completion of preconditioning, the target values for engine speed and torque shall be changed linearly within 20 to 46 seconds to the highest target torque setpoint at the next higher target engine speed setpoint than the particular target engine speed setpoint where the interruption of the FCMC occurred. If the target setpoint is reached within less than 46 seconds, the remaining time up to 46 seconds shall be used for stabilization. For stabilization the engine operation shall continue from that point in accordance with the test sequence specified in paragraph 4.3.5.5 without recording of measurement values. When the highest target torque setpoint at the particular target engine speed setpoint where the interruption occurred is reached, the recording of measurement values shall be continued from that point on in accordance with the test sequence specified in paragraph 4.3.5.5.
The 10 target engine speed setpoints are defined by 4 base target engine speed setpoints and 6 additional target engine speed setpoints. The engine speeds nidle, nlo, npref, n95h and nhi shall be determined from the engine full load curve of the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3 to this Annex and recorded in accordance with paragraph 4.3.1 by applying the definitions of characteristic engine speeds in accordance with paragraph 7.4.6. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . The engine speed n57 shall be determined by the following equation: n57 = 0,565 × (0,45 × nlo + 0,45 × npref + 0,1 × nhi – nidle) × 2,0327 + nidle The 4 base target engine speed setpoints are defined as follows: Base engine speed 1: nidle Base engine speed 2: nA = n57 – 0,05 × (n95h – nidle) Base engine speed 3: nB = n57 + 0,08 × (n95h – nidle) Base engine speed 4: n95h The potential distances between the speed setpoints shall be determined by the following equations: dnidleA_44 = (nA – nidle) / 4 dnB95h_44 = (n95h – nB) / 4 dnidleA_35 = (nA – nidle) / 3 dnB95h_35 = (n95h – nB) / 5 dnidleA_53 = (nA – nidle) / 5 dnB95h_53 = (n95h – nB) / 3 The absolute values of potential deviations between the two sections shall be determined by the following equations: dn44 = ABS(dnidleA_44 – dnB95h_44) dn35 = ABS(dnidleA_35 – dnB95h_35) dn53 = ABS(dnidleA_53 – dnB95h_53) The 6 additional target engine speed setpoints shall be determined in accordance with the following provisions: If dn44 is smaller than or equal to (dn35 + 5) and also smaller than or equal to (dn53 + 5), the 6 additional target engine speeds shall be determined by dividing each of the two ranges, one from nidle to nA and the other from nB to n95h, into 4 equidistant sections. If (dn35 + 5) is smaller than dn44 and also dn35 is smaller than dn53, the 6 additional target engine speeds shall be determined by dividing the range from nidle to nA into 3 equidistant sections and the range from nB to n95h, into 5 equidistant sections. If (dn53 + 5) is smaller than dn44 and also dn53 is smaller than dn35, the 6 additional target engine speeds shall be determined by dividing the range from nidle to nA into 5 equidistant sections and the range from nB to n95h, into 3 equidistant sections. Figure 1 exemplarily illustrates the definition of the target engine speed setpoints according to subpoint (1) above.
The 11 target torque setpoints are defined by 2 base target torque setpoints and 9 additional target torque setpoints. The 2 base target torque setpoints are defined by zero engine torque and the maximum engine full load of the CO2-parent engine determined in accordance with paragraph 4.3.1. (overall maximum torque Tmax_overall). The 9 additional target torque setpoints are determined by dividing the range from zero torque to overall maximum torque, Tmax_overall, into 10 equidistant sections. ►M3 All target torque setpoints at a particular target engine speed setpoint that exceed the limit value defined by the full load torque value (determined from the engine full load curve recorded in accordance with point 4.3.1) at this particular target engine speed setpoint minus 5 percent % of Tmax_overall, shall be replaced by one single target torque setpoint at full load torque at this particular target engine speed setpoint. ◄ Each of these replacement setpoints shall be measured only once during the FCMC test sequence defined in accordance with paragraph 4.3.5.5. Figure 2 exemplarily illustrates the definition of the target torque setpoints.
The following measurement data shall be recorded: engine speed engine torque corrected in accordance with paragraph 3.1.2 fuel mass flow consumed by the whole engine system in accordance with paragraph 3.4 Gaseous pollutants according to the definitions in UN/ECE Regulation 49 Rev.06. Particulate pollutants and ammonia emissions are not required to be monitored during the FCMC testrun. The measurement of gaseous pollutants shall be carried out in accordance with paragraphs 7.5.1, 7.5.2, 7.5.3, 7.5.5, 7.7.4, 7.8.1, 7.8.2, 7.8.4 and 7.8.5 of Annex 4 to UN/ECE Regulation 49 Rev.06. For the purpose of paragraph 7.8.4 of Annex 4 to UN/ECE Regulation 49 Rev.06, the term ‘test cycle’ in the paragraph referred to shall be the complete sequence from preconditioning in accordance with paragraph 4.3.5.4 to ending of the test sequence in accordance with paragraph 4.3.5.5.
The dilution system, if applicable, and the engine shall be started and warmed up in accordance with paragraph 7.4.1. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . After warm-up is completed, the engine and sampling system shall be preconditioned by operating the engine for 20 minutes at mode 9, as defined in Table 1 of paragraph 7.2.2. of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , while simultaneously operating the dilution system. The engine full load curve of the CO2-parent engine of the engine CO2-family and recorded in accordance with paragraph point 4.3.1 shall be used for the denormalization denormalisation of the reference values of mode 9 performed in accordance with paragraphs 7.4.6, 7.4.7 and 7.4.8 of Annex 4 to UN/ECE UN Regulation 49 Rev.06. No. 49. Directly after completion of preconditioning, the target values for engine speed and torque shall be changed linearly within 20 to 46 seconds to match the first target setpoint of the test sequence according to paragraph 4.3.5.5. If the first target setpoint is reached within less than 46 seconds, the remaining time up to 46 seconds shall be used for stabilization.
4.3.5.5 Test sequencechanged
The test sequence consists of steady state target setpoints with defined engine speed and torque at each target setpoint in accordance with paragraph 4.3.5.2 and defined ramps to move from one target setpoint to the next. The highest target torque setpoint at each target engine speed shall be operated with maximum operator demand. The first target setpoint is defined at the highest target engine speed setpoint and highest target torque setpoint. The following steps shall be performed to cover all target setpoints: The engine shall be operated for 95 ± 3 seconds at each target setpoint. The first 55 ± 1 seconds at each target setpoint are considered as a stabilization period,. During the following period of 30 ± 1 seconds the engine speed mean value shall be controlled as follows: The engine speed mean value shall be held at the target engine speed setpoint within ± 1 percent of the highest target engine speed. Except for the points at full load, the engine torque mean value shall be held at the target torque setpoint within a tolerance of ± 20 Nm or ± 2 percent of the overall maximum torque, Tmax_overall, whichever is greater. The recorded values in accordance with paragraph 4.3.5.3 shall be stored as averaged value over the period of 30 ± 1 seconds. The remaining period of 10 ± 1 seconds may be used for data post-processing and storage if necessary. During this period the engine target setpoint shall be kept. After the measurement at one target setpoint is completed, the target value for engine speed shall be kept constant within ± 20 min– 1 of the target engine speed setpoint and the target value for torque shall be decreased linearly within 20±1 seconds to match the next lower target torque setpoint. Then the measurement shall be performed according to subpoint (1). After the zero torque setpoint has been measured in subpoint (1), the target engine speed shall be decreased linearly to the next lower target engine speed setpoint while at the same time the target torque shall be increased linearly to the highest target torque setpoint at the next lower target engine speed setpoint within 20 to 46 seconds. If the next target setpoint is reached within less than 46 seconds, the remaining time up to 46 seconds shall be used for stabilization. Then the measurement shall be performed by starting the the stabilization procedure according to subpoint (1) and afterwards the target torque setpoints at constant target engine speed shall be adjusted according to subpoint (2). Figure 3 illustrates the three different steps to be performed at each measurement setpoint for the test according to subpoint (1) above.
Text of image Transition period (ramp) Transition period (ramp) Post-processing period 55 ± 1 seconds 10 ± 1 s. 30 ± 1 seconds Measurement period (Data recording) Stabilization period Phase end 95 ± 3 seconds Phase start Figure 4 exemplarily illustrates the sequence of steady state measurement setpoints to be followed for the test.
Gaseous pollutants in accordance with paragraph 4.3.5.3 shall be monitored during the FCMC. The definitions of characteristic engine speeds in accordance with paragraph 7.4.6. of Annex 4 to UN/ECE R.49.06 ►M3 UN Regulation No. 49 ◄ shall apply.
The control area defined in accordance with paragraph 4.3.5.6.1 shall be divided into a number of grid cells for emission monitoring during the FCMC. The grid shall comprise of 9 cells for engines with a rated speed less than 3 000 min– 1 and 12 cells for engines with a rated speed greater than or equal to 3 000 min– 1. The grids shall be defined in accordance with the following provisions: The outer boundaries of the grids are aligned to the control area defined according to paragraph 4.3.5.6.1. 2 vertical lines spaced at equal distance between engine speeds n30 and 1,1 times n95h for 9 cell grids, or 3 vertical lines spaced at equal distance between engine speeds n30 and 1,1 times n95h for 12 cell grids. 2 lines spaced at equal distance of engine torque (i.e. 1/3) at each vertical line of engine speed defined by subpoints (1) and (2) All engine speed values in min-1 and all torque values in Newtonmeters defining the boundaries of the grid cells shall be rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06. Figure 6 exemplarily illustrates the definition of the grid cells for the control area in the case of 9 cell grid.
The specific mass emissions of the gaseous pollutants shall be determined as average value for each grid cell defined in accordance with paragraph 4.3.5.6.2. The average value for each grid cell shall be determined as arithmetical mean value of the specific mass emissions over all engine speed and torque points measured during the FCMC located within the same grid cell. The specific mass emissions of the single engine speed and torque points measured during the FCMC shall be determined as averaged value over the 30 ± 1 30±1 seconds measurement period defined in accordance with point 4.3.5.5., subpoint (1) of paragraph 4.3.5.5. If an engine speed and torque point is located directly on a line that separates different grid cells from each other, this engine speed and load point shall be taken into account for the average values of all adjacent grid cells. The calculation of the total mass emissions of each gaseous pollutant for each engine speed and torque point measured during the FCMC, mFCMC,i in grams, over the 30 ± 1 seconds measurement period in accordance with subpoint (1) of paragraph 4.3.5.5 shall be carried out in accordance with paragraph 8 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . The actual engine work for each engine speed and torque point measured during the FCMC, WFCMC,i in kWh, over the 30 ± 1 seconds measurement period in accordance with subpoint (1) of paragraph 4.3.5.5 shall be determined from the engine speed and torque values recorded in accordance with paragraph 4.3.5.3. The specific mass emissions of gaseous pollutants eFCMC,i in g/kWh for each engine speed and torque point measured during the FCMC shall be determined by the following equation: eFCMC,i = mFCMC,i / WFCMC,i
A linear regression analysis of the actual values of engine speed (nact), engine torque (Mact) and engine power (Pact) on the respective reference values (nref, Mref, Pref) shall be performed for the FCMC. The actual values for nact, Mact and Pact shall be the determined from the values recorded in accordance with paragraph 4.3.5.3. The ramps to move from one target setpoint to the next shall be excluded from this regression analysis. To minimize the biasing effect of the time lag between the actual and reference cycle values, the entire engine speed and torque actual signal sequence may be advanced or delayed in time with respect to the reference speed and torque sequence. If the actual signals are shifted, both speed and torque shall be shifted by the same amount in the same direction. The method of least squares shall be used for the regression analysis in accordance with paragraphs A.3.1 and A.3.2 of Appendix 3 to Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , with the best-fit equation having the form as defined in paragraph 7.8.7 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . It is recommended that this analysis be performed at 1 Hz. For the purposes of this regression analysis only, omissions of points are permitted where noted in Table 4 (Permitted point omissions from regression analysis) of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06 ◄ before doing the regression calculation. Additionally, all engine torque and power values at points with maximum operator demand shall be omitted for the purposes of this regression analysis only. However, points omitted for the purposes of regression analysis shall not be omitted for any other calculations in accordance with this Annex. Point omission may be applied to the whole or to any part of the cycle. For the data to be considered valid, the criteria of Table 3 (Regression line tolerances for the WHSC) of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06 ◄ shall be met.
The data obtained from the FCMC tests is valid if the specific mass emissions of the regulated gaseous pollutants determined for each grid cell in accordance with paragraph point 4.3.5.6.3 meet the applicable following limits for gaseous pollutants defined in paragraph 5.2.2 of Annex 10 to UN/ECE Regulation 49 Rev.06. In the case that the number of engine speed and torque points within the same grid cell is less than 3, this paragraph shall not apply for that specific grid cell. pollutants:
Total engine work over a cycle or a defined period shall be determined from the recorded values of engine power determined in accordance with paragraph 3.1.2 of this Annex and paragraphs 6.3.5 and 7.4.8 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . The engine work over a complete testcycle or over each WHTC-sub-cycle shall be determined by integrating of recorded values of engine power in accordance with the following formula: where: Wact, i | = | total engine work over the time period from t0 to t1 t0 | = | time at the start of the time period t1 | = | time at the end of the time period n | = | number of recorded values over the time period from t0 to t1 Pk [0 … n] | = | recorded engine power values over the time period from t0 to t1 in chronological order, where k runs from 0 at t0 to n at t1 h | = | interval width between two adjacent recorded values defined by
The specific fuel consumption figures needed for the WHTC correction factor shall be calculated from the actual measured values for the hotstart WHTC recorded in accordance with paragraph 4.3.3 as follows: where: SFCmeas, i | = | Specific fuel consumption over the WHTC-sub-cycle i [g/kWh] Σ FCmeas, i | = | Total fuel mass consumed by the engine over the WHTC-sub-cycle i [g] determined in accordance with paragraph 5.2 Wact, i | = | Total engine work over the WHTC sub-cycle i [kWh] determined in accordance with paragraph 5.1 The 3 different sub-cycles of the WHTC – urban, rural and motorway – shall be defined as follows: urban: from cycle start to ≤ 900 seconds from cycle start rural: from > 900 seconds to ≤ 1 380 seconds from cycle start motorway (MW): from > 1 380 seconds from cycle start to cycle end
The specific fuel consumption over the WHSC shall be calculated from the actual measured values for the WHSC recorded in accordance with paragraph point 4.3.4 as follows: SFCWHSC = (Σ FCWHSC) / (WWHSC) (WWHSC + Σ E_WHRWHSC) where: SFCWHSC | = | Specific fuel consumption over WHSC [g/kWh] Σ FCWHSC | = | Total fuel consumption over the WHSC [g] determined in accordance with paragraph point 5.2 of this Annex WWHSC | = | Total engine work over the WHSC [kWh] dddetermined in accordance with point 5.1 of this Annex For engines with more than one WHR system installed E_WHRWHSC shall be calculated for each different WHR system separately. For engines without a WHR system installed E_WHRWHSC shall be set to zero. E_WHRWHSC = Total integrated E_WHR_net over the WHSC [kWh] determined in accordance with paragraph 5.1 point 5.3 Σ E_WHRWHSC = Sum of this Annex individual E_WHRWHSC of all different WHR systems installed [kWh].
The calculated specific fuel consumption over the WHSC, SFCWHSC, determined in accordance with paragraph 5.3.3 shall be adjusted to a corrected value, SFCWHSC,corr, in order to account for the difference between the NCV of the fuel used during testing and the standard NCV for the respective engine fuel technology in accordance with the following equation: where: SFCWHSC,corr | = | Corrected specific fuel consumption over WHSC [g/kWh] SFCWHSC | = | Specific fuel consumption over WHSC [g/kWh] NCVmeas | = | NCV of the fuel used during testing determined in accordance with paragraph 3.2 [MJ/kg] NCVstd | = | Standard NCV in accordance with Table 4 [MJ/kg] Table 4 Standard net calorific values of fuel types Fuel type / engine type | Reference fuel type | Standard NCV [MJ/kg] Diesel / CI | B7 | 42,7 Ethanol / CI | ED95 | 25,7 Petrol / PI | E10 | 41,5 Ethanol / PI | E85 | 29,1 LPG / PI | LPG Fuel B | 46,0 ▼M1 ►M3 Natural gas / PI or Natural Gas / CI ◄ | G25 or GR | 45,1 ▼M4 Hydrogen / PI or Hydrogen / CI | Hydrogen | 120,0 Diesel / CI | B100 | 37,2 ▼B
For engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis defined in accordance with paragraph 6.6.1 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , fuel consumption shall be adjusted to account for regeneration events by a correction factor. This correction factor, CFRegPer, shall be determined in accordance with paragraph 6.6.2 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . For engines equipped with exhaust after-treatment systems with continuous regeneration, defined in accordance with paragraph 6.6 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06, ◄ , no correction factor shall be determined and the value of the factor CFRegPer shall be set to 1. The engine full load curve recorded in accordance with paragraph 4.3.1 shall be used for the denormalization of the WHTC reference cycle and all calculations of reference values performed in accordance with paragraphs 7.4.6, 7.4.7 and 7.4.8 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . In addition to the provisions defined in Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06 ◄ the actual fuel mass flow consumed by the engine in accordance with paragraph 3.4 shall be recorded for each WHTC hot start test performed in accordance with paragraph 6.6.2 of Annex 4 to UN/ECE ►M3 UN Regulation No. 49 Rev.06. ◄ . The specific fuel consumption for each WHTC hot start test performed shall be calculated by the following equation: SFCmeas, m = (Σ FCmeas, m) / (Wact, m) where: SFCmeas, m | = | Specific fuel consumption [g/kWh] Σ FCmeas,m | = | Total fuel consumption over the WHTC [g] determined in accordance with paragraph 5.2 of this Annex Wact, m | = | Total engine work over the WHTC [kWh] determined in accordance with paragraph 5.1 of this Annex m | = | Index defining each individual WHTC hot start test The specific fuel consumption values for the individual WHTC tests shall be weighted by the following equation: where: n | = | the number of WHTC hot start tests without regeneration nr | = | the number of WHTC hot start tests with regeneration (minimum number is one test) SFCavg | = | the average specific fuel consumption from all WHTC hot start tests without regeneration [g/kWh] SFCavg,r | = | the average specific fuel consumption from all WHTC hot start tests with regeneration [g/kWh] The correction factor, CFRegPer, shall be calculated by the following equation:
The input data shall be the values of engine speed, engine torque and fuel massflow determined for the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3 to of this Annex and recorded in accordance with paragraph point 4.3.5. In the case that upon request of the manufacturer the provisions defined in Article 15(5) of this Regulation are applied, the values of engine speed, engine torque and fuel massflow determined for that specific engine recorded in accordance with paragraph point 4.3.5 shall be used as input data. The input data shall only consist of the average measurement values of engine speed, engine torque and fuel massflow over the 30 ± 1 30±1 seconds measurement period determined in accordance with subpoint (1) of paragraph point 4.3.5.5. The input data shall be provided in the file format of ‘comma “comma separated values’ values” with the separator character being the Unicode Character ‘COMMA’ (U+002C) (‘,’). The first line of the file shall be used as a header heading and not contain any recorded data. The recorded data shall start from the second line of the file. The heading of each column in the first column line of the file shall be defines the expected content of the respective column. The column for engine speed shall have the string ‘engine speed’ as heading in min– 1 the first line of the file. The data values shall start from the second line of the file in min–1 rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06. The column for torque shall have the string “torque” as heading in the first line of the file. The data values shall start from the second column shall be line of the torque file in Nm rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06. The third column shall be the for fuel massflow shall have the string “massflow fuel 1” as heading in the first line of the file. The data values shall start from the second line of the file in g/h rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06.
6.1.9 Type of test fuelchanged
The input data shall be the type of the test fuel selected in accordance with paragraph 3.2. In case of a diesel engine tested with a reference fuel type of B100 in accordance with point 3.2, ‘Diesel B100 CI’ shall be the input to the engine pre-processing tool
2. Definitionschanged
For the purposes of this Annex the following definitions shall apply: ‘Transfer case’ means a device that splits the engine power of a vehicle and directs it to the front and rear drive axles. It is mounted behind the transmission and both front and rear drive shafts connect to it. It comprises either a gearwheel set or a chain drive system in which the power is distributed from the transmission to the axles. The transfer case will typically have the ability to shift between standard drive mode (front or rear wheel drive), high range traction mode (front and rear wheel drive), low range traction mode and neutral; ‘Gear ratio’ means the forward gear ratio of the speed of the input shaft (towards prime mover) to the speed of the output shaft (towards driven wheels) without slip (i = nin/nout ); ‘Ratio coverage’ means the ratio of the largest to the smallest forward gear ratios in a transmission: φtot = imax/imin ; ‘Compound transmission’ means a transmission, with a large number of forward gears and/or large ratio coverage, composed of sub-transmissions, which are combined to use most power-transferring parts in several forward gears; ‘Main section’ means the sub-transmission that has the largest number of forward gears in a compound transmission; ‘Range section’ means a sub-transmission normally in series connection with the main section in a compound transmission. A range section usually has two shiftable forward gears. The lower forward gears of the complete transmission are embodied using the low range gear. The higher gears are embodied using the high range gear; ‘Splitter’ means a design that splits the main section gears in two (usually) variants, low- and high split gears, whose gear ratios are close compared to the ratio coverage of the transmission. A splitter can be a separate sub-transmission, an add-on device, integrated with the main section or a combination thereof; ‘Tooth clutch’ means a clutch where torque is transferred mainly by normal forces between mating teeth. A tooth clutch can either be engaged or disengaged. It is operated in load-free conditions, only (e.g., at gear shifts in a manual transmission); ‘Angle drive’ means a device that transmits rotational power between non-parallel shafts, often used with transversely oriented engine and longitudinal input to driven axle; ‘Friction clutch’ means clutch for transfer of propulsive torque, where torque is sustainably transferred by friction forces. A friction clutch can transmit torque while slipping, it can thereby (but does not have to) be operated at start-offs and at powershifts (retained power transfer during a gear shift); ‘Synchroniser’ means a type of tooth clutch where a friction device is used to equalise the speeds of the rotating parts to be engaged; ‘Gear mesh efficiency’ means the ratio of output power to input power when transmitted in a forward gear mesh with relative motion; ‘Crawler gear’ means a low forward gear (with speed reduction ratio that is larger than for the non-crawler gears) that is designed to be used infrequently, e.g., at low-speed manoeuvres or occasional up-hill start-offs; ‘Power take-off (PTO)’ means a device on a transmission or an engine to which an auxiliary driven device, e.g., a hydraulic pump, can be connected; ‘Power take-off drive mechanism’ means a device in a transmission that allows the installation of a power take-off (PTO); ‘Lock-up clutch’ means a friction clutch in a hydrodynamic torque converter; it can connect the input and output sides, thereby eliminating the slip; ‘Start-off clutch’ means a clutch that adapts speed between engine and driven wheels when the vehicle starts off. The start-off clutch is usually located between engine and transmission; ‘Synchronised Manual Transmission (SMT)’ means a manually operated transmission with two or more selectable speed ratios that are obtained using synchronisers. Ratio changing is normally achieved during a temporary disconnection of the transmission from the engine using a clutch (usually the vehicle start-off clutch); ‘Automated Manual Transmission or Automatic Mechanically-engaged Transmission (AMT)’ means an automatically shifting transmission with two or more selectable speed ratios that are obtained using tooth clutches (un-/synchronised). Ratio changing is achieved during a temporary disconnection of the transmission from the engine. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutch between engine and gearbox and the speed and torque of the engine. The system selects and engages the most suitable forward gear automatically, but can be overridden by the driver using a manual mode; ‘Dual Clutch Transmission (DCT)’ means an automatically shifting transmission with two friction clutches and several selectable speed ratios that are obtained by the use of tooth clutches. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutches and the speed and torque of the engine. The system selects the most suitable gear automatically, but can be overridden by the driver using a manual mode; ‘Retarder’ means an auxiliary braking device in a vehicle powertrain; aimed for permanent braking; ‘Case S’ means the serial arrangement of a torque converter and the connected mechanical parts of the transmission; ‘Case P’ means the parallel arrangement of a torque converter and the connected mechanical parts of the transmission (e.g. in power split installations); ‘Automatic Powershifting Transmission (APT)’ means an automatically shifting transmission with more than two friction clutches and several selectable speed ratios that are obtained mainly by the use of those friction clutches. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutches and the speed and torque of the engine. The system selects the most suitable gear automatically, but can be overridden by the driver using a manual mode. Shifts are normally performed without traction interruption (friction clutch to friction clutch); ‘Oil conditioning system’ means an external system that conditions the oil of a transmission at testing. The system circulates oil to and from the transmission. The oil is thereby filtered and/or temperature conditioned; ‘Smart lubrication system’ means a system that will affect the load independent losses (also called spin losses or drag losses) of the transmission depending on the input torque and/or power flow through the transmission. Examples are controlled hydraulic pressure pumps for brakes and clutches in an APT, controlled variable oil level in the transmission, controlled variable oil flow/pressure for lubrication and cooling in the transmission. Smart lubrication can also include control of the oil temperature of the transmission, but smart lubrication systems that are designed only for controlling the temperature are not considered here, since the transmission testing procedure has fixed testing temperatures; ‘Transmission electric auxiliary’ means an electric auxiliary used for the function of the transmission during running steady state operation. A typical example is an electric cooling/lubrication pump (but not electric gear shift actuators and electronic control systems including electric solenoid valves, since they are low energy consumers, especially at steady state operation); ‘Oil type viscosity grade’ means a viscosity grade as defined by SAE J306; ‘Factory fill oil’ means the oil type viscosity grade that is used for the oil fill in the factory and which is intended to stay in the transmission, torque converter, other torque transferring component or in an additional driveline component for the first service interval; ‘Gearscheme’ means the arrangement of shafts, gearwheels and clutches in a transmission; ‘Powerflow’ means the transfer path of power from input to output in a transmission via shafts, gearwheels and clutches.
For testing the losses of a transmission the torque loss map for each individual transmission type shall be measured. Transmissions may be grouped into families with similar or equal CO2-relevant data following the provisions of Appendix 6 to this Annex. For the determination of the transmission torque losses, the applicant for a certificate shall apply one of the following methods for each single forward gear (crawler gears excluded). Option 1: Measurement of the torque independent losses, calculation of the torque dependent losses. Option 2: Measurement of the torque independent losses, measurement of the torque loss at maximum torque and interpolation of the torque dependent losses based on a linear model Option 3: Measurement of the total torque loss. 3.1 | Option 1: Measurement of the torque independent losses, calculation of the torque dependent losses. The torque loss Tl ,in on the input shaft of the transmission shall be calculated by Tl,in (nin , Tin , gear) = T l,in,min_loss + fT * Tin + floss_corr * Tin + T l,in,min_el + fel_corr * Tin The correction factor for the torque dependent hydraulic torque losses shall be calculated by The correction factor for the torque dependent electric torque losses shall be calculated by The torque loss at the input shaft of the transmission caused by the power consumption of transmission electric auxiliary shall be calculated by where: Tl,in = Torque loss related to input shaft [Nm] Tl,in,min_loss = Torque independent loss at minimum hydraulic loss level (minimum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] Tl,in,max_loss = Torque independent loss at maximum hydraulic loss level (maximum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] floss_corr = Loss correction for hydraulic loss level depending on input torque [-] nin = Speed at the transmission input shaft (downstream of torque converter, if applicable) [rpm] fT = Torque loss coefficient = 1 – ηT Tin = Torque at the input shaft [Nm] ηT = Torque dependent efficiency (to be calculated); for a direct gear fT = 0,007 (ηT = 0,993) [-] fel_corr = Loss correction for electric power loss level depending on input torque [-] Tl,in, el = Additional torque loss on input shaft by electric consumers [Nm] Tl,in,min_el = Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] Tl,in,max_el = Additional torque loss on input shaft by electric consumers corresponding to maximum electric power [Nm] Pel = Electric power consumption of electric consumers in transmission measured during transmission loss testing [W] Tmax,in = Maximum allowed input torque for any forward gear in the transmission [Nm] 3.1.1. The torque dependent losses of a transmission system shall be determined as described in the following: In case of multiple parallel and nominally equal power flows, e.g., twin countershafts or several planet gearwheels in a planetary gear set, that can be treated as one power flow in this section. 3.1.1.1. For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed: 3.1.1.2. For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm: external – external gear meshes : ηm = 0,986 external – internal gear meshes : ηm = 0,993 angle drive gear meshes : ηm = 0,97 (Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex) 3.1.1.3. The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %. 3.1.1.4. The total torque dependent efficiency η Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n 3.1.1.5. The torque dependent loss coefficient fTg for the gear g shall be calculated by: fTg = 1 – η Tg 3.1.1.6. The torque dependent loss Tl,inTg on the input shaft for gear g shall be calculated by: Tl,inTg = fTg * Tin 3.1.1.7. The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by: where: ηm,ring = Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-] ηm,sun = Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-] zsun = Number of teeth of the sun gearwheel of the range section [-] zring = Number of teeth of the ring gearwheel of the range section [-] The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4. 3.1.1.8. For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. In this case, for each indirect gear g, the following steps shall be performed: 3.1.1.9. Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni ) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction. 3.1.1.10. For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by: Nsun–carrier = Nsun – Ncarrier Nring–carrier = Nring – Ncarrier where: Nsun = Rotational speed of sun gearwheel [rad/s] Nring = Rotational speed of ring gearwheel [rad/s] Ncarrier = Rotational speed of carrier [rad/s] 3.1.1.11. The loss-producing powers in the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the power P shall be calculated by: P 1 = N 1 · T 1 P 2 = N 2 · T 2 where: P = Power of gear mesh [W] N = Rotational speed of gearwheel [rad/s] T = Torque of gearwheel [Nm] For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by: Pv,sun = Tsun · (Nsun – Ncarrier ) = Tsun · Nsun/carrier Pv,ring = Tring · (Nring – Ncarrier ) = Tring · Nring/carrier where: Pv,sun = Virtual power of sun gearwheel [W] Pv,ring = Virtual power of ring gearwheel [W] Tsun = Torque of sun gearwheel [Nm] Tcarrier = Torque of carrier [Nm] Tring = Torque of ring gearwheel [Nm] Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm : Pi > 0 ⇒ Pi,adj = Pi Pi < 0 ⇒ Pi,adj = Pi · η mi where: Padj = Loss-adjusted powers of the gear meshes [W] ηm = Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-] For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring : Pv,i ≥ 0 ⇒ Pi,adj = Pv,i Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring where: ηmsun = Torque dependent efficiency of sun-to-planet [-] ηmring = Torque dependent efficiency of ring-to-planet [-] 3.1.1.12. All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss of the transmission system referring to the input power: Pm,loss = ΣPi,adj where: i = All gearwheels with a fix rotational axis [-] Pm,loss = Torque dependent gear mesh power loss of the transmission system [W] 3.1.1.13. The torque dependent loss coefficient for bearings, fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh shall be added to receive the total torque dependent loss coefficient fT for the transmission system: fT = fT,gearmesh + fT,bear where: fT = Total torque dependent loss coefficient for the transmission system [-] fT,bear = Torque dependent loss coefficient for the bearings [-] fT,gearmesh = Torque dependent loss coefficient for the gear meshes [-] Pin = Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W] 3.1.1.14. The torque dependent losses on the input shaft for the specific gear shall be calculated by: Tl,inT = fT * Tin where: Tl,inT = Torque dependent loss related to input shaft [Nm] Tin = Torque at the input shaft [Nm] 3.1.2. The torque independent losses shall be measured in accordance with the procedure described in the following. 3.1.2.1. General requirements The transmission used for the measurements shall be in accordance with the drawing specifications for series production transmissions and shall be new. Modifications to the transmission to meet the testing requirements of this Annex, e.g. for the inclusion of measurement sensors or adaption of an external oil conditioning system are permitted. The tolerance limits in this paragraph refer to measurement values without sensor uncertainty. ▼M1 Total tested time per transmission individual and gear shall not exceed 5 times the actual testing time per gear (allowing re-testing of transmission if needed due to measuring or rig error). ▼B The same transmission individual may be used for a maximum of 10 different tests, e.g. for tests of transmission torque losses for variants with and without retarder (with different temperature requirements) or with different oils. If the same transmission individual is used for tests of different oils, the recommended factory fill oil shall be tested first. It is not permitted to run a certain test multiple times to choose a test series with the lowest results. Upon request of the approval authority the applicant for a certificate shall specify and prove the conformity with the requirements defined in this Annex. 3.1.2.2. Differential measurements To subtract influences caused by the test rig setup (e.g. bearings, clutches) from the measured torque losses, differential measurements are permitted to determine these parasitic torques. The measurements shall be performed at the same speed steps and same test rig bearing temperature(s) ± 3 K used for the testing. The torque sensor measurement uncertainty shall be below 0,3 Nm. 3.1.2.3. Run-in On request of the applicant a run-in procedure may be applied to the transmission. The following provisions shall apply for a run-in procedure. 3.1.2.3.1. The procedure shall not exceed 30 hours per gear and 100 hours in total. 3.1.2.3.2. The application of the input torque shall be limited to 100 % of maximum input torque. 3.1.2.3.3. The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.3.4. The speed and torque profile for the run-in procedure shall be specified by the manufacturer. 3.1.2.3.5. The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority. 3.1.2.3.6. The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure. 3.1.2.4. Pre-conditioning 3.1.2.4.1. Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed. 3.1.2.4.2. The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. 3.1.2.4.3. The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.4.4. The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed 60 minutes. 3.1.2.4.5. The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures. 3.1.2.5. Test conditions 3.1.2.5.1. Ambient temperature The ambient temperature during the test shall be in a range of 25 °C ± 10 K. The ambient temperature shall be measured 1 m laterally from the transmission. The ambient temperature limit shall not apply for the run-in procedure. 3.1.2.5.2. Oil temperature Except for the oil, no external heating is allowed. During measurement (except stabilization) the following temperature limits shall apply: For SMT/AMT/DCT transmissions, the drain plug oil temperature shall not exceed 83 °C when measuring without retarder and 87 °C with retarder mounted to the transmission. If measurements of a transmission without retarder are to be combined with separate measurements of a retarder, the lower temperature limit shall apply to compensate for the retarder drive mechanism and step-up gear and for the clutch in case of a disengageable retarder. For torque converter planetary transmissions and for transmissions having more than two friction clutches, the drain plug oil temperature shall not exceed 93 °C without retarder and 97 °C with retarder. To apply the above defined increased temperature limits for testing with retarder, the retarder shall be integrated in the transmission or have an integrated cooling or oil system with the transmission. During the run-in, the same oil temperature specifications as for regular testing shall apply. Exceptional oil temperature peaks up to 110 °C are allowed for the following conditions: (1) during run-in procedure up to maximum of 10 % of the applied run-in time, (2) during stabilization time. The oil temperature shall be measured at the drain plug or in the oil sump. 3.1.2.5.3. Oil quality New, recommended first fill oil for the European market shall be used in the test. The same oil fill may be used for run-in and torque measurement. 3.1.2.5.4. Oil viscosity If multiple oils are recommended for first fill, they are considered to be equal if the oils have a kinematic viscosity within 10 % of each other at the same temperature (within the specified tolerance band for KV100). Any oil with lower viscosity than the oil used in the test shall be considered to result in lower losses for the tests performed within this option. Any additional first fill oil must fall either in the 10 % tolerance band or have lower viscosity than the oil in the test to be covered by the same certificate. 3.1.2.5.5. Oil level and conditioning The oil level shall meet the nominal specifications for the transmission. If an external oil conditioning system is used, the oil inside the transmission shall be kept to the specified volume that corresponds to the specified oil level. To guarantee that the external oil conditioning system is not influencing the test, one test point shall be measured with the conditioning system both on and off. The deviation between the two measurements of the torque loss (= input torque) shall be less than 5 %. The test point is specified as follows: (1) gear = highest indirect gear, (2) input speed = 1 600 rpm, (3) temperatures as specified under 3.1.2.5. For transmissions with hydraulic pressure control or a smart lubrication system, the measurement of torque independent losses shall be performed with two different settings: first with the transmission system pressure set to at least the minimum value for conditions with engaged gear and a second time with the maximum possible hydraulic pressure (see 3.1.6.3.1). 3.1.3. Installation 3.1.3.1. The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft shall rotate freely. 3.1.3.2. The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°. 3.1.3.3. The internal oil pump shall be included in the transmission. 3.1.3.4. If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test. 3.1.3.5 Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in Annex VII to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off. 3.1.3.6. Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test. 3.1.3.7. The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8. 3.1.4. Measurement equipmentThe calibration laboratory facilities shall comply with the requirements of either ISO/TS 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards. 3.1.4.1. Torque The torque sensor measurement uncertainty shall be below 0,3 Nm. The use of torque sensors with higher measurement uncertainties is allowed if the part of the uncertainty exceeding 0,3 Nm can be calculated and is added to the measured torque loss as described in 3.1.8. Measurement uncertainty. 3.1.4.2. Speed The uncertainty of the speed sensors shall not exceed ± 1 rpm. 3.1.4.3. Temperature The uncertainty of the temperature sensors for the measurement of the ambient temperature shall not exceed ± 1,5 K. The uncertainty of the temperature sensors for the measurement of the oil temperature shall not exceed ± 1,5 K. 3.1.4.4. Pressure The uncertainty of the pressure sensors shall not exceed 1 % of the maximum measured pressure. 3.1.4.5. Voltage The uncertainty of the voltmeter shall not exceed 1 % of the maximum measured voltage. 3.1.4.6. Electric current The uncertainty of the amperemeter shall not exceed 1 % of the maximum measured current. 3.1.5. Measurement signals and data recordingAt least the following signals shall be recorded during the measurement: (1) Input torques [Nm] (2) Input rotational speeds [rpm] (3) Ambient temperature [°C] (4) Oil temperature [°C] If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded: (5) Oil pressure [kPa] If the transmission is equipped with transmission electric auxiliary, additionally to be recorded: (6) Voltage of transmission electric auxiliary [V] (7) Current of transmission electric auxiliary [A] For differential measurements for the compensation of influences caused by the test rig setup, additionally shall be recorded: (8) Test rig bearing temperature [°C] The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to reduce measurement errors. 3.1.6. Test procedure3.1.6.1. Zero torque signal compensation: The zero-signal of the torque sensor(s) shall be measured. For the measurement the sensor(s) shall be installed in the test rig. The drivetrain of the test rig (input & output) shall be free of load. The measured signal deviation from zero shall be compensated. 3.1.6.2. Speed range: The torque loss shall be measured for the following speed steps (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , […] rpm up to the maximum speed per gear according to the specifications of the transmission or the last speed step before the defined maximum speed. The speed ramp (time for the change between two speed steps) shall not extend 20 seconds. 3.1.6.3. Measurement sequence: 3.1.6.3.1. If the transmission is equipped with smart lubrication systems and/or transmission electric auxiliaries, the measurement shall be conducted with two measurement settings of of these systems: A first measurement sequence (3.1.6.3.2. to 3.1.6.3.4.) shall be performed with the lowest power consumption by hydraulical and electrical systems when operated in the vehicle (low loss level). The second measurement sequence shall be performed with the systems set to work with the highest possible power consumption when operated in the vehicle (high loss level). 3.1.6.3.2. The measurements shall be performed beginning with the lowest up to the highest speed. 3.1.6.3.3. For each speed step a minimum of 5 seconds stabilization time within the temperature limits defined in 3.1.2.5 is required. If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. Oil and ambient temperatures shall be recorded during the stabilization. 3.1.6.3.4. After the stabilization time, the measurement signals listed in 3.1.5. shall be recorded for the test point for 05-15 seconds. 3.1.6.3.5. Each measurement shall be performed two times per measurement setting. 3.1.7. Measurement validation 3.1.7.1. The arithmetic mean values of torque, speed, (if applicable) voltage and current for the 05-15 seconds measurement shall be calculated for each of the measurements. 3.1.7.2. The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series. 3.1.7.3. The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: Tloss = Tin Pel = I * U It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.). 3.1.7.4. The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). 3.1.7.5. The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.6. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. 3.1.7.7. The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.8. If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. 3.1.8. Measurement uncertaintyThe part of the calculated total uncertainty UT,loss exceeding 0,3 Nm shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 0,3 Nm, then Tloss,rep = Tloss . Tloss,rep = Tloss + MAX (0, (UT,loss – 0,3 Nm)) The total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters: (1) Temperature effect (2) Parasitic loads (3) Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’). wpara = senspara * ipara where: Tloss = Measured torque loss (uncorrected) [Nm] Tloss,rep = Reported torque loss (after uncertainty correction) [Nm] UT,loss = Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] UT,in = Uncertainty of input torque loss measurement [Nm] uTKC = Uncertainty by temperature influence on current torque signal [Nm] wtkc = Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] uTK0 = Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 = Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] Kref = Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] ΔK = Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. Tc = Current/measured torque value at torque sensor [Nm] Tn = Nominal torque value of torque sensor [Nm] ucal = Uncertainty by torque sensor calibration [Nm] Wcal = Relative calibration uncertainty (related to nominal torque) [%] kcal = Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) upara = Uncertainty by parasitic loads [Nm] wpara = senspara * ipara Relative influence of forces and bending torques caused by misalignment senspara = Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara = Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). = A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. Figure 1 Test setup A for Option 1 = B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. Figure 2 Test setup B for Option 1 = C) 100 % for other setups Tl,in | = | Torque loss related to input shaft [Nm] Tl,in,min_loss | = | Torque independent loss at minimum hydraulic loss level (minimum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] Tl,in,max_loss | = | Torque independent loss at maximum hydraulic loss level (maximum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] floss_corr | = | Loss correction for hydraulic loss level depending on input torque [-] nin | = | Speed at the transmission input shaft (downstream of torque converter, if applicable) [rpm] fT | = | Torque loss coefficient = 1 – ηT Tin | = | Torque at the input shaft [Nm] ηT | = | Torque dependent efficiency (to be calculated); for a direct gear fT = 0,007 (ηT = 0,993) [-] fel_corr | = | Loss correction for electric power loss level depending on input torque [-] Tl,in, el | = | Additional torque loss on input shaft by electric consumers [Nm] Tl,in,min_el | = | Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] Tl,in,max_el | = | Additional torque loss on input shaft by electric consumers corresponding to maximum electric power [Nm] Pel | = | Electric power consumption of electric consumers in transmission measured during transmission loss testing [W] Tmax,in | = | Maximum allowed input torque for any forward gear in the transmission [Nm] 3.1.1. | The torque dependent losses of a transmission system shall be determined as described in the following: In case of multiple parallel and nominally equal power flows, e.g., twin countershafts or several planet gearwheels in a planetary gear set, that can be treated as one power flow in this section. 3.1.1.1. For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed: 3.1.1.2. For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm: external – external gear meshes : ηm = 0,986 external – internal gear meshes : ηm = 0,993 angle drive gear meshes : ηm = 0,97 (Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex) 3.1.1.3. The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %. 3.1.1.4. The total torque dependent efficiency η Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n 3.1.1.5. The torque dependent loss coefficient fTg for the gear g shall be calculated by: fTg = 1 – η Tg 3.1.1.6. The torque dependent loss Tl,inTg on the input shaft for gear g shall be calculated by: Tl,inTg = fTg * Tin 3.1.1.7. The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by: where: ηm,ring = Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-] ηm,sun = Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-] zsun = Number of teeth of the sun gearwheel of the range section [-] zring = Number of teeth of the ring gearwheel of the range section [-] The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4. 3.1.1.8. For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. In this case, for each indirect gear g, the following steps shall be performed: 3.1.1.9. Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni ) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction. 3.1.1.10. For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by: Nsun–carrier = Nsun – Ncarrier Nring–carrier = Nring – Ncarrier where: Nsun = Rotational speed of sun gearwheel [rad/s] Nring = Rotational speed of ring gearwheel [rad/s] Ncarrier = Rotational speed of carrier [rad/s] 3.1.1.11. The loss-producing powers in the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the power P shall be calculated by: P 1 = N 1 · T 1 P 2 = N 2 · T 2 where: P = Power of gear mesh [W] N = Rotational speed of gearwheel [rad/s] T = Torque of gearwheel [Nm] For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by: Pv,sun = Tsun · (Nsun – Ncarrier ) = Tsun · Nsun/carrier Pv,ring = Tring · (Nring – Ncarrier ) = Tring · Nring/carrier where: Pv,sun = Virtual power of sun gearwheel [W] Pv,ring = Virtual power of ring gearwheel [W] Tsun = Torque of sun gearwheel [Nm] Tcarrier = Torque of carrier [Nm] Tring = Torque of ring gearwheel [Nm] Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm : Pi > 0 ⇒ Pi,adj = Pi Pi < 0 ⇒ Pi,adj = Pi · η mi where: Padj = Loss-adjusted powers of the gear meshes [W] ηm = Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-] For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring : Pv,i ≥ 0 ⇒ Pi,adj = Pv,i Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring where: ηmsun = Torque dependent efficiency of sun-to-planet [-] ηmring = Torque dependent efficiency of ring-to-planet [-] 3.1.1.12. All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss of the transmission system referring to the input power: Pm,loss = ΣPi,adj where: i = All gearwheels with a fix rotational axis [-] Pm,loss = Torque dependent gear mesh power loss of the transmission system [W] 3.1.1.13. The torque dependent loss coefficient for bearings, fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh shall be added to receive the total torque dependent loss coefficient fT for the transmission system: fT = fT,gearmesh + fT,bear where: fT = Total torque dependent loss coefficient for the transmission system [-] fT,bear = Torque dependent loss coefficient for the bearings [-] fT,gearmesh = Torque dependent loss coefficient for the gear meshes [-] Pin = Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W] 3.1.1.14. The torque dependent losses on the input shaft for the specific gear shall be calculated by: Tl,inT = fT * Tin where: Tl,inT = Torque dependent loss related to input shaft [Nm] Tin = Torque at the input shaft [Nm] 3.1.1.1. | For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed: 3.1.1.2. | For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm: external – external gear meshes : ηm = 0,986 external – internal gear meshes : ηm = 0,993 angle drive gear meshes : ηm = 0,97 (Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex) external – external gear meshes | : | ηm = 0,986 external – internal gear meshes | : | ηm = 0,993 angle drive gear meshes | : | ηm = 0,97 3.1.1.3. | The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %. 3.1.1.4. | The total torque dependent efficiency η Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n 3.1.1.5. | The torque dependent loss coefficient fTg for the gear g shall be calculated by: fTg = 1 – η Tg 3.1.1.6. | The torque dependent loss Tl,inTg on the input shaft for gear g shall be calculated by: Tl,inTg = fTg * Tin 3.1.1.7. | The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by: where: ηm,ring = Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-] ηm,sun = Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-] zsun = Number of teeth of the sun gearwheel of the range section [-] zring = Number of teeth of the ring gearwheel of the range section [-] The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4. ηm,ring | = | Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-] ηm,sun | = | Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-] zsun | = | Number of teeth of the sun gearwheel of the range section [-] zring | = | Number of teeth of the ring gearwheel of the range section [-] 3.1.1.8. | For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. In this case, for each indirect gear g, the following steps shall be performed: 3.1.1.9. | Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni ) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction. 3.1.1.10. | For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by: Nsun–carrier = Nsun – Ncarrier Nring–carrier = Nring – Ncarrier where: Nsun = Rotational speed of sun gearwheel [rad/s] Nring = Rotational speed of ring gearwheel [rad/s] Ncarrier = Rotational speed of carrier [rad/s] Nsun | = | Rotational speed of sun gearwheel [rad/s] Nring | = | Rotational speed of ring gearwheel [rad/s] Ncarrier | = | Rotational speed of carrier [rad/s] 3.1.1.11. | The loss-producing powers in the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the power P shall be calculated by: P 1 = N 1 · T 1 P 2 = N 2 · T 2 where: P = Power of gear mesh [W] N = Rotational speed of gearwheel [rad/s] T = Torque of gearwheel [Nm] For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by: Pv,sun = Tsun · (Nsun – Ncarrier ) = Tsun · Nsun/carrier Pv,ring = Tring · (Nring – Ncarrier ) = Tring · Nring/carrier where: Pv,sun = Virtual power of sun gearwheel [W] Pv,ring = Virtual power of ring gearwheel [W] Tsun = Torque of sun gearwheel [Nm] Tcarrier = Torque of carrier [Nm] Tring = Torque of ring gearwheel [Nm] Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm : Pi > 0 ⇒ Pi,adj = Pi Pi < 0 ⇒ Pi,adj = Pi · η mi where: Padj = Loss-adjusted powers of the gear meshes [W] ηm = Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-] For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring : Pv,i ≥ 0 ⇒ Pi,adj = Pv,i Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring where: ηmsun = Torque dependent efficiency of sun-to-planet [-] ηmring = Torque dependent efficiency of ring-to-planet [-] P | = | Power of gear mesh [W] N | = | Rotational speed of gearwheel [rad/s] T | = | Torque of gearwheel [Nm] Pv,sun | = | Virtual power of sun gearwheel [W] Pv,ring | = | Virtual power of ring gearwheel [W] Tsun | = | Torque of sun gearwheel [Nm] Tcarrier | = | Torque of carrier [Nm] Tring | = | Torque of ring gearwheel [Nm] Padj | = | Loss-adjusted powers of the gear meshes [W] ηm | = | Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-] ηmsun | = | Torque dependent efficiency of sun-to-planet [-] ηmring | = | Torque dependent efficiency of ring-to-planet [-] 3.1.1.12. | All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss of the transmission system referring to the input power: Pm,loss = ΣPi,adj where: i = All gearwheels with a fix rotational axis [-] Pm,loss = Torque dependent gear mesh power loss of the transmission system [W] i | = | All gearwheels with a fix rotational axis [-] Pm,loss | = | Torque dependent gear mesh power loss of the transmission system [W] 3.1.1.13. | The torque dependent loss coefficient for bearings, fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh shall be added to receive the total torque dependent loss coefficient fT for the transmission system: fT = fT,gearmesh + fT,bear where: fT = Total torque dependent loss coefficient for the transmission system [-] fT,bear = Torque dependent loss coefficient for the bearings [-] fT,gearmesh = Torque dependent loss coefficient for the gear meshes [-] Pin = Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W] fT | = | Total torque dependent loss coefficient for the transmission system [-] fT,bear | = | Torque dependent loss coefficient for the bearings [-] fT,gearmesh | = | Torque dependent loss coefficient for the gear meshes [-] Pin | = | Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W] 3.1.1.14. | The torque dependent losses on the input shaft for the specific gear shall be calculated by: Tl,inT = fT * Tin where: Tl,inT = Torque dependent loss related to input shaft [Nm] Tin = Torque at the input shaft [Nm] Tl,inT | = | Torque dependent loss related to input shaft [Nm] Tin | = | Torque at the input shaft [Nm] 3.1.2. | The torque independent losses shall be measured in accordance with the procedure described in the following. 3.1.2.1. General requirements The transmission used for the measurements shall be in accordance with the drawing specifications for series production transmissions and shall be new. Modifications to the transmission to meet the testing requirements of this Annex, e.g. for the inclusion of measurement sensors or adaption of an external oil conditioning system are permitted. The tolerance limits in this paragraph refer to measurement values without sensor uncertainty. ▼M1 Total tested time per transmission individual and gear shall not exceed 5 times the actual testing time per gear (allowing re-testing of transmission if needed due to measuring or rig error). ▼B The same transmission individual may be used for a maximum of 10 different tests, e.g. for tests of transmission torque losses for variants with and without retarder (with different temperature requirements) or with different oils. If the same transmission individual is used for tests of different oils, the recommended factory fill oil shall be tested first. It is not permitted to run a certain test multiple times to choose a test series with the lowest results. Upon request of the approval authority the applicant for a certificate shall specify and prove the conformity with the requirements defined in this Annex. 3.1.2.2. Differential measurements To subtract influences caused by the test rig setup (e.g. bearings, clutches) from the measured torque losses, differential measurements are permitted to determine these parasitic torques. The measurements shall be performed at the same speed steps and same test rig bearing temperature(s) ± 3 K used for the testing. The torque sensor measurement uncertainty shall be below 0,3 Nm. 3.1.2.3. Run-in On request of the applicant a run-in procedure may be applied to the transmission. The following provisions shall apply for a run-in procedure. 3.1.2.3.1. The procedure shall not exceed 30 hours per gear and 100 hours in total. 3.1.2.3.2. The application of the input torque shall be limited to 100 % of maximum input torque. 3.1.2.3.3. The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.3.4. The speed and torque profile for the run-in procedure shall be specified by the manufacturer. 3.1.2.3.5. The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority. 3.1.2.3.6. The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure. 3.1.2.4. Pre-conditioning 3.1.2.4.1. Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed. 3.1.2.4.2. The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. 3.1.2.4.3. The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.4.4. The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed 60 minutes. 3.1.2.4.5. The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures. 3.1.2.5. Test conditions 3.1.2.5.1. Ambient temperature The ambient temperature during the test shall be in a range of 25 °C ± 10 K. The ambient temperature shall be measured 1 m laterally from the transmission. The ambient temperature limit shall not apply for the run-in procedure. 3.1.2.5.2. Oil temperature Except for the oil, no external heating is allowed. During measurement (except stabilization) the following temperature limits shall apply: For SMT/AMT/DCT transmissions, the drain plug oil temperature shall not exceed 83 °C when measuring without retarder and 87 °C with retarder mounted to the transmission. If measurements of a transmission without retarder are to be combined with separate measurements of a retarder, the lower temperature limit shall apply to compensate for the retarder drive mechanism and step-up gear and for the clutch in case of a disengageable retarder. For torque converter planetary transmissions and for transmissions having more than two friction clutches, the drain plug oil temperature shall not exceed 93 °C without retarder and 97 °C with retarder. To apply the above defined increased temperature limits for testing with retarder, the retarder shall be integrated in the transmission or have an integrated cooling or oil system with the transmission. During the run-in, the same oil temperature specifications as for regular testing shall apply. Exceptional oil temperature peaks up to 110 °C are allowed for the following conditions: (1) during run-in procedure up to maximum of 10 % of the applied run-in time, (2) during stabilization time. The oil temperature shall be measured at the drain plug or in the oil sump. 3.1.2.5.3. Oil quality New, recommended first fill oil for the European market shall be used in the test. The same oil fill may be used for run-in and torque measurement. 3.1.2.5.4. Oil viscosity If multiple oils are recommended for first fill, they are considered to be equal if the oils have a kinematic viscosity within 10 % of each other at the same temperature (within the specified tolerance band for KV100). Any oil with lower viscosity than the oil used in the test shall be considered to result in lower losses for the tests performed within this option. Any additional first fill oil must fall either in the 10 % tolerance band or have lower viscosity than the oil in the test to be covered by the same certificate. 3.1.2.5.5. Oil level and conditioning The oil level shall meet the nominal specifications for the transmission. If an external oil conditioning system is used, the oil inside the transmission shall be kept to the specified volume that corresponds to the specified oil level. To guarantee that the external oil conditioning system is not influencing the test, one test point shall be measured with the conditioning system both on and off. The deviation between the two measurements of the torque loss (= input torque) shall be less than 5 %. The test point is specified as follows: (1) gear = highest indirect gear, (2) input speed = 1 600 rpm, (3) temperatures as specified under 3.1.2.5. For transmissions with hydraulic pressure control or a smart lubrication system, the measurement of torque independent losses shall be performed with two different settings: first with the transmission system pressure set to at least the minimum value for conditions with engaged gear and a second time with the maximum possible hydraulic pressure (see 3.1.6.3.1). 3.1.2.3.1. | The procedure shall not exceed 30 hours per gear and 100 hours in total. 3.1.2.3.2. | The application of the input torque shall be limited to 100 % of maximum input torque. 3.1.2.3.3. | The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.3.4. | The speed and torque profile for the run-in procedure shall be specified by the manufacturer. 3.1.2.3.5. | The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority. 3.1.2.3.6. | The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure. 3.1.2.4.1. | Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed. 3.1.2.4.2. | The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. 3.1.2.4.3. | The maximum input speed shall be limited by the specified maximum speed for the transmission. 3.1.2.4.4. | The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed 60 minutes. 3.1.2.4.5. | The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures. 3.1.3. | Installation 3.1.3.1. The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft shall rotate freely. 3.1.3.2. The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°. 3.1.3.3. The internal oil pump shall be included in the transmission. 3.1.3.4. If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test. 3.1.3.5 Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in Annex VII to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off. 3.1.3.6. Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test. 3.1.3.7. The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8. 3.1.3.1. | The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft shall rotate freely. 3.1.3.2. | The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°. 3.1.3.3. | The internal oil pump shall be included in the transmission. 3.1.3.4. | If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test. 3.1.3.5 | Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in Annex VII to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off. 3.1.3.6. | Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test. 3.1.3.7. | The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8. 3.1.4. | Measurement equipmentThe calibration laboratory facilities shall comply with the requirements of either ISO/TS 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards. 3.1.4.1. Torque The torque sensor measurement uncertainty shall be below 0,3 Nm. The use of torque sensors with higher measurement uncertainties is allowed if the part of the uncertainty exceeding 0,3 Nm can be calculated and is added to the measured torque loss as described in 3.1.8. Measurement uncertainty. 3.1.4.2. Speed The uncertainty of the speed sensors shall not exceed ± 1 rpm. 3.1.4.3. Temperature The uncertainty of the temperature sensors for the measurement of the ambient temperature shall not exceed ± 1,5 K. The uncertainty of the temperature sensors for the measurement of the oil temperature shall not exceed ± 1,5 K. 3.1.4.4. Pressure The uncertainty of the pressure sensors shall not exceed 1 % of the maximum measured pressure. 3.1.4.5. Voltage The uncertainty of the voltmeter shall not exceed 1 % of the maximum measured voltage. 3.1.4.6. Electric current The uncertainty of the amperemeter shall not exceed 1 % of the maximum measured current. 3.1.5. | Measurement signals and data recordingAt least the following signals shall be recorded during the measurement: (1) Input torques [Nm] (2) Input rotational speeds [rpm] (3) Ambient temperature [°C] (4) Oil temperature [°C] If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded: (5) Oil pressure [kPa] If the transmission is equipped with transmission electric auxiliary, additionally to be recorded: (6) Voltage of transmission electric auxiliary [V] (7) Current of transmission electric auxiliary [A] For differential measurements for the compensation of influences caused by the test rig setup, additionally shall be recorded: (8) Test rig bearing temperature [°C] The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to reduce measurement errors. 3.1.6. | Test procedure3.1.6.1. Zero torque signal compensation: The zero-signal of the torque sensor(s) shall be measured. For the measurement the sensor(s) shall be installed in the test rig. The drivetrain of the test rig (input & output) shall be free of load. The measured signal deviation from zero shall be compensated. 3.1.6.2. Speed range: The torque loss shall be measured for the following speed steps (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , […] rpm up to the maximum speed per gear according to the specifications of the transmission or the last speed step before the defined maximum speed. The speed ramp (time for the change between two speed steps) shall not extend 20 seconds. 3.1.6.3. Measurement sequence: 3.1.6.3.1. If the transmission is equipped with smart lubrication systems and/or transmission electric auxiliaries, the measurement shall be conducted with two measurement settings of of these systems: A first measurement sequence (3.1.6.3.2. to 3.1.6.3.4.) shall be performed with the lowest power consumption by hydraulical and electrical systems when operated in the vehicle (low loss level). The second measurement sequence shall be performed with the systems set to work with the highest possible power consumption when operated in the vehicle (high loss level). 3.1.6.3.2. The measurements shall be performed beginning with the lowest up to the highest speed. 3.1.6.3.3. For each speed step a minimum of 5 seconds stabilization time within the temperature limits defined in 3.1.2.5 is required. If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. Oil and ambient temperatures shall be recorded during the stabilization. 3.1.6.3.4. After the stabilization time, the measurement signals listed in 3.1.5. shall be recorded for the test point for 05-15 seconds. 3.1.6.3.5. Each measurement shall be performed two times per measurement setting. 3.1.7. | Measurement validation 3.1.7.1. The arithmetic mean values of torque, speed, (if applicable) voltage and current for the 05-15 seconds measurement shall be calculated for each of the measurements. 3.1.7.2. The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series. 3.1.7.3. The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: Tloss = Tin Pel = I * U It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.). 3.1.7.4. The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). 3.1.7.5. The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.6. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. 3.1.7.7. The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.8. If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. 3.1.7.1. | The arithmetic mean values of torque, speed, (if applicable) voltage and current for the 05-15 seconds measurement shall be calculated for each of the measurements. 3.1.7.2. | The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series. 3.1.7.3. | The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: Tloss = Tin Pel = I * U It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.). 3.1.7.4. | The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). 3.1.7.5. | The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.6. | If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. 3.1.7.7. | The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.1.7.8. | If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. 3.1.8. | Measurement uncertaintyThe part of the calculated total uncertainty UT,loss exceeding 0,3 Nm shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 0,3 Nm, then Tloss,rep = Tloss . Tloss,rep = Tloss + MAX (0, (UT,loss – 0,3 Nm)) The total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters: (1) Temperature effect (2) Parasitic loads (3) Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’). wpara = senspara * ipara where: Tloss = Measured torque loss (uncorrected) [Nm] Tloss,rep = Reported torque loss (after uncertainty correction) [Nm] UT,loss = Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] UT,in = Uncertainty of input torque loss measurement [Nm] uTKC = Uncertainty by temperature influence on current torque signal [Nm] wtkc = Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] uTK0 = Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 = Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] Kref = Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] ΔK = Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. Tc = Current/measured torque value at torque sensor [Nm] Tn = Nominal torque value of torque sensor [Nm] ucal = Uncertainty by torque sensor calibration [Nm] Wcal = Relative calibration uncertainty (related to nominal torque) [%] kcal = Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) upara = Uncertainty by parasitic loads [Nm] wpara = senspara * ipara Relative influence of forces and bending torques caused by misalignment senspara = Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara = Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). = A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. Figure 1 Test setup A for Option 1 = B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. Figure 2 Test setup B for Option 1 = C) 100 % for other setups Tloss | = | Measured torque loss (uncorrected) [Nm] Tloss,rep | = | Reported torque loss (after uncertainty correction) [Nm] UT,loss | = | Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] UT,in | = | Uncertainty of input torque loss measurement [Nm] uTKC | = | Uncertainty by temperature influence on current torque signal [Nm] wtkc | = | Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] uTK0 | = | Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 | = | Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] Kref | = | Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] ΔK | = | Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. Tc | = | Current/measured torque value at torque sensor [Nm] Tn | = | Nominal torque value of torque sensor [Nm] ucal | = | Uncertainty by torque sensor calibration [Nm] Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] kcal | = | Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) upara | = | Uncertainty by parasitic loads [Nm] wpara | = | senspara * ipara Relative influence of forces and bending torques caused by misalignment senspara | = | Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara | = | Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). = | A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. Figure 1 Test setup A for Option 1 = | B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. Figure 2 Test setup B for Option 1 = | C) 100 % for other setups 3.2. | Option 2: Measurement of the torque independent losses, measurement of the torque loss at maximum torque and interpolation of the torque dependent losses based on a linear modelOption 2 describes the determination of the torque loss by a combination of measurements and linear interpolation. Measurements shall be performed for the torque independent losses of the transmission and for one load point of the torque dependent losses (maximum input torque). Based on the torque losses at no load and at maximum input torque, the torque losses for the input torques in between shall be calculated with the torque loss coefficient fTlimo . The torque loss Tl,in on the input shaft of the transmission shall be calculated by Tl,in (nin , Tin , gear) = Tl,in,min_loss + fTlimo * Tin + T l,in,min_el + fel_corr * Tin The torque loss coefficient based on the linear model fTlimo shall be calculated by where: Tl,in = Torque loss related to input shaft [Nm] Tl,in,min_loss = Drag torque loss at transmission input, measured with free rotating output shaft from testing without load [Nm] nin = Speed at the input shaft [rpm] fTlimo = Torque loss coefficient based on linear model [-] Tin = Torque at the input shaft [Nm] Tin,maxT = Maximum tested torque at the input shaft (normally 100 % input torque, refer to 3.2.5.2. and 3.4.4.) [Nm] Tl,maxT = Torque loss related to input shaft with Tin = Tin,maxT fel_corr = Loss correction for electric power loss level depending on input torque [-] Tl,in,el = Additional torque loss on input shaft by electric consumers [Nm] Tl,in,min_el = Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] The correction factor for the torque dependent electric torque losses fel_corr and the torque loss at the input shaft of the transmission caused by the power consumption of transmission electric auxiliary Tl,in,el shall be calculated as described in paragraph 3.1. 3.2.1. The torque losses shall be measured in accordance with the procedure described in the following. 3.2.1.1. General requirements: As specified for Option 1 in 3.1.2.1. 3.2.1.2. Differential measurements: As specified for Option 1 in 3.1.2.2. 3.2.1.3. Run-in As specified for Option 1 in 3.1.2.3. 3.2.1.4. Pre-conditioning As specified for Option 3 in 3.3.2.1. 3.2.1.5. Test conditions 3.2.1.5.1. Ambient temperature As specified for Option 1 in 3.1.2.5.1. 3.2.1.5.2. Oil temperature As specified for Option 1 in 3.1.2.5.2. 3.2.1.5.3. Oil quality / Oil viscosity As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.2.1.5.4. Oil level and conditioning As specified for Option 3 in 3.3.3.4. 3.2.2. InstallationAs specified for Option 1 in 3.1.3. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.4. for the measurement of the torque dependent losses. 3.2.3. Measurement equipmentAs specified for Option 1 in 3.1.4. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.5. for the measurement of the torque dependent losses. 3.2.4. Measurement signals and data recordingAs specified for Option 1 in 3.1.5 for the measurement of the torque independent losses. As specified for Option 3 in 3.3.7 for the measurement of the torque dependent losses. 3.2.5. Test procedureThe torque loss map to be applied to the simulation tool contains the torque loss values of a transmission depending on rotational input speed and input torque. To determine the torque loss map for a transmission, the basic torque loss map data shall be measured and calculated as specified in this paragraph. The torque loss results shall be complemented in accordance with 3.4 and formatted in accordance with Appendix 12 for the further processing by the simulation tool. 3.2.5.1. The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers. 3.2.5.2. Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply. 3.2.6. Measurement validationAs specified for Option 3 in 3.3.8. 3.2.7. Measurement uncertaintyAs specified for Option 1 in 3.1.8. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.9. for the measurement of the torque dependent loss. Tl,in | = | Torque loss related to input shaft [Nm] Tl,in,min_loss | = | Drag torque loss at transmission input, measured with free rotating output shaft from testing without load [Nm] nin | = | Speed at the input shaft [rpm] fTlimo | = | Torque loss coefficient based on linear model [-] Tin | = | Torque at the input shaft [Nm] Tin,maxT | = | Maximum tested torque at the input shaft (normally 100 % input torque, refer to 3.2.5.2. and 3.4.4.) [Nm] Tl,maxT | = | Torque loss related to input shaft with Tin = Tin,maxT fel_corr | = | Loss correction for electric power loss level depending on input torque [-] Tl,in,el | = | Additional torque loss on input shaft by electric consumers [Nm] Tl,in,min_el | = | Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] 3.2.1. | The torque losses shall be measured in accordance with the procedure described in the following. 3.2.1.1. General requirements: As specified for Option 1 in 3.1.2.1. 3.2.1.2. Differential measurements: As specified for Option 1 in 3.1.2.2. 3.2.1.3. Run-in As specified for Option 1 in 3.1.2.3. 3.2.1.4. Pre-conditioning As specified for Option 3 in 3.3.2.1. 3.2.1.5. Test conditions 3.2.1.5.1. Ambient temperature As specified for Option 1 in 3.1.2.5.1. 3.2.1.5.2. Oil temperature As specified for Option 1 in 3.1.2.5.2. 3.2.1.5.3. Oil quality / Oil viscosity As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.2.1.5.4. Oil level and conditioning As specified for Option 3 in 3.3.3.4. 3.2.2. | InstallationAs specified for Option 1 in 3.1.3. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.4. for the measurement of the torque dependent losses. 3.2.3. | Measurement equipmentAs specified for Option 1 in 3.1.4. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.5. for the measurement of the torque dependent losses. 3.2.4. | Measurement signals and data recordingAs specified for Option 1 in 3.1.5 for the measurement of the torque independent losses. As specified for Option 3 in 3.3.7 for the measurement of the torque dependent losses. 3.2.5. | Test procedureThe torque loss map to be applied to the simulation tool contains the torque loss values of a transmission depending on rotational input speed and input torque. To determine the torque loss map for a transmission, the basic torque loss map data shall be measured and calculated as specified in this paragraph. The torque loss results shall be complemented in accordance with 3.4 and formatted in accordance with Appendix 12 for the further processing by the simulation tool. 3.2.5.1. The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers. 3.2.5.2. Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply. 3.2.5.1. | The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers. 3.2.5.2. | Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply. 3.2.6. | Measurement validationAs specified for Option 3 in 3.3.8. 3.2.7. | Measurement uncertaintyAs specified for Option 1 in 3.1.8. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.9. for the measurement of the torque dependent loss. 3.3. | Option 3: Measurement of the total torque loss.Option 3 describes the determination of the torque loss by full measurement of the torque dependent losses including the torque independent losses of the transmission. 3.3.1. General requirements As specified for Option 1 in 3.1.2.1. 3.3.1.1 Differential measurements: As specified for Option 1 in 3.1.2.2. 3.3.2. Run-in As specified for Option 1 in 3.1.2.3. 3.3.2.1 Pre-conditioning As specified for Option 1 in 3.1.2.4. with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or target torque on the output shaft set to zero. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. or The requirements as specified in 3.1.2.4. shall apply, with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or the torque on the output shaft being within +/- 50 Nm. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. or, if the test rig includes a (master friction) clutch at the input shaft: The requirements as specified in 3.1.2.4. shall apply, with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or without applied torque to the input shaft. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. The transmission would then be driven from the output side. Those proposals could also be combined. 3.3.3. Test conditions 3.3.3.1. Ambient temperature As specified for Option 1 in 3.1.2.5.1. 3.3.3.2. Oil temperature As specified for Option 1 in 3.1.2.5.2. 3.3.3.3. Oil quality / Oil viscosity As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.3.3.4. Oil level and conditioning The requirements as specified in 3.1.2.5.5. shall apply, diverging in the following: The test point for the external oil conditioning system is specified as follows: (1) highest indirect gear, (2) input speed = 1 600 rpm, (3) input torque = maximum input torque for the highest indirect gear 3.3.4. Installation The test rig shall be driven by electric machines (input and output). Torque sensors shall be installed at the input and output side of the transmission. Other requirements as specified in 3.1.3. shall apply. 3.3.5. Measurement equipment For the measurement of the torque independent losses, the measurement equipment requirements as specified for Option 1 in 3.1.4. shall apply. For the measurement of the torque dependent losses, the following requirements shall apply: The torque sensor measurement uncertainty shall be below 5 % of the measured torque loss or 1 Nm (whichever value is larger). The use of torque sensors with higher measurement uncertainties is allowed if the parts of the uncertainty exceeding 5 % or 1 Nm can be calculated and the smaller of those parts is added to the measured torque loss. The torque measurement uncertainty shall be calculated and included as described under 3.3.9. Other measurement equipment requirements as specified for Option 1 in 3.1.4. shall apply. 3.3.6. Test procedure 3.3.6.1. Zero torque signal compensation: As specified in 3.1.6.1. 3.3.6.2. Speed range The torque loss shall be measured for the following speed steps (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , […] rpm up to the maximum speed per gear according to the specifications of the transmission or the last speed step before the defined maximum speed. The speed ramp (time for the change between two speed steps) shall not exceed 20 seconds. 3.3.6.3. Torque range For each speed step the torque loss shall be measured for the following input torques: 0 (free rotating output shaft), 200, 400, 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 3 500 , 4 000 , […] Nm up to the maximum input torque per gear according to the specifications of the transmission or the last torque step before the defined maximum torque and/or the last torque step before the output torque of 10 kNm. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply. The torque ramp (time for the change between two torque steps) shall not exceed 15 seconds (180 seconds for option 2). To cover the complete torque range of a transmission in the above defined map, different torque sensors with limited measurement ranges may be used on the input/output side. Therefore the measurement may be divided into sections using the same set of torque sensors. The overall torque loss map shall be composed of these measurement sections. 3.3.6.4. Measurement sequence 3.3.6.4.1. The measurements shall be performed beginning with the lowest up to the highest speed. 3.3.6.4.2. The input torque shall be varied according to the above defined torque steps from the lowest to the highest torque which is covered by the current torque sensors for each speed step. 3.3.6.4.3. For each speed and torque step a minimum of 5 seconds stabilization time within the temperature limits defined in 3.3.3. is required. If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds (maximum 180 seconds for option 2). Oil and ambient temperatures shall be recorded during the stabilization. 3.3.6.4.4. The measurement set shall be performed two times in total. For that purpose, sequenced repetition of sections using the same set of torque sensors is allowed. 3.3.7. Measurement signals and data recording At least the following signals shall be recorded during the measurement: (1) Input and output torques [Nm] (2) Input and output rotational speeds [rpm] (3) Ambient temperature [°C] (4) Oil temperature [°C] If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded: (5) Oil pressure [kPa] If the transmission is equipped with transmission electric auxiliary, additionally to be recorded: (6) Voltage of transmission electric auxiliary [V] (7) Current of transmission electric auxiliary [A] For differential measurements for compensation of influences by test rig setup, additionally to be recorded: (8) Test rig bearing temperature [°C] The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to avoid measurement errors. 3.3.8. Measurement validation 3.3.8.1. The arithmetic mean values of torque, speed, if applicable voltage and current for the 05-15 seconds measurement shall be calculated for each of the two measurements. 3.3.8.2. The measured and averaged speed at the input shaft shall be below ± 5 rpm of the speed set point for each measured operating point for the complete torque loss series. ►M1 The measured and averaged torque at the input shaft shall be below ± 5 Nm or ± 0,5 % of the torque set point whichever value is larger for each measured operating point for the complete torque loss series. ◄ 3.3.8.3. The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: Pel = I * U It is allowed to subtract influences caused by the test rig setup from the torque losses (3.3.2.2.). 3.3.8.4. The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). 3.3.8.5. The deviation between the averaged torque losses of the two measurement sets shall be below ± 5 % of the average or ± 1 Nm (whichever value is larger). The arithmetic average of the two averaged torque loss values shall be taken. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. 3.3.8.6. The deviation between the averaged electric power consumption (voltage*current) values of the two measurement sets shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.3.8.7. If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. 3.3.9. Measurement uncertainty The part of the calculated total uncertainty UT,loss exceeding 5 % of Tloss or 1 Nm (ΔUT,loss ), whichever value of ΔUT,loss is smaller, shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 5 % of Tloss or 1 Nm, then Tloss,rep = Tloss . Tloss,rep = Tloss + MAX (0, ΔUT,loss ) ΔUT,loss = MIN ((UT,loss – 5 % * Tloss ), (UT,loss – 1 Nm)) For each measurement set, the total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters: (1) Temperature effect (2) Parasitic loads (3) Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’). wpara = senspara * ipara where: Tloss = Measured torque loss (uncorrected) [Nm] Tloss,rep = Reported torque loss (after uncertainty correction) [Nm] UT,loss = Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] uT,in/out = Uncertainty of input/output torque loss measurement separately for input and output torque sensor[Nm] igear = Gear ratio [-] uTKC = Uncertainty by temperature influence on current torque signal [Nm] wtkc = Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] uTK0 = Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 = Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] Kref = Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] ΔK = Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. Tc = Current/measured torque value at torque sensor [Nm] Tn = Nominal torque value of torque sensor [Nm] ucal = Uncertainty by torque sensor calibration [Nm] Wcal = Relative calibration uncertainty (related to nominal torque) [%] kcal = calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) upara = Uncertainty by parasitic loads [Nm] wpara = senspara * ipara Relative influence of forces and bending torques caused by misalignment [%] senspara = Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara = Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). = A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 3. Figure 3 Test setup A for Option 3 = B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 4. Figure 4 Test setup B for Option 3 = C) 100 % for other setups 3.3.6.4.1. | The measurements shall be performed beginning with the lowest up to the highest speed. 3.3.6.4.2. | The input torque shall be varied according to the above defined torque steps from the lowest to the highest torque which is covered by the current torque sensors for each speed step. 3.3.6.4.3. | For each speed and torque step a minimum of 5 seconds stabilization time within the temperature limits defined in 3.3.3. is required. If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds (maximum 180 seconds for option 2). Oil and ambient temperatures shall be recorded during the stabilization. 3.3.6.4.4. | The measurement set shall be performed two times in total. For that purpose, sequenced repetition of sections using the same set of torque sensors is allowed. 3.3.8.1. | The arithmetic mean values of torque, speed, if applicable voltage and current for the 05-15 seconds measurement shall be calculated for each of the two measurements. 3.3.8.2. | The measured and averaged speed at the input shaft shall be below ± 5 rpm of the speed set point for each measured operating point for the complete torque loss series. ►M1 The measured and averaged torque at the input shaft shall be below ± 5 Nm or ± 0,5 % of the torque set point whichever value is larger for each measured operating point for the complete torque loss series. ◄ 3.3.8.3. | The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: Pel = I * U It is allowed to subtract influences caused by the test rig setup from the torque losses (3.3.2.2.). 3.3.8.4. | The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). 3.3.8.5. | The deviation between the averaged torque losses of the two measurement sets shall be below ± 5 % of the average or ± 1 Nm (whichever value is larger). The arithmetic average of the two averaged torque loss values shall be taken. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. 3.3.8.6. | The deviation between the averaged electric power consumption (voltage*current) values of the two measurement sets shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. 3.3.8.7. | If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. Tloss | = | Measured torque loss (uncorrected) [Nm] Tloss,rep | = | Reported torque loss (after uncertainty correction) [Nm] UT,loss | = | Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] uT,in/out | = | Uncertainty of input/output torque loss measurement separately for input and output torque sensor[Nm] igear | = | Gear ratio [-] uTKC | = | Uncertainty by temperature influence on current torque signal [Nm] wtkc | = | Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] uTK0 | = | Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 | = | Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] Kref | = | Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] ΔK | = | Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. Tc | = | Current/measured torque value at torque sensor [Nm] Tn | = | Nominal torque value of torque sensor [Nm] ucal | = | Uncertainty by torque sensor calibration [Nm] Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] kcal | = | calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) upara | = | Uncertainty by parasitic loads [Nm] wpara | = | senspara * ipara Relative influence of forces and bending torques caused by misalignment [%] senspara | = | Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara | = | Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). = | A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 3. Figure 3 Test setup A for Option 3 = | B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 4. Figure 4 Test setup B for Option 3 = | C) 100 % for other setups 3.4. | Complement of input files for the simulation toolFor each gear a torque loss map covering the defined input speed and input torque steps shall be determined with one of the specified testing options or standard torque loss values. For the input file for the simulation tool, this basic torque loss map shall be complemented as described in the following: 3.4.1. In the cases the highest tested input speed was the last speed step below the defined maximum permissible transmission speed, an extrapolation of the torque loss shall be applied up to the maximum speed with linear regression based on the two last measured speed steps. 3.4.2. In the cases the highest tested input torque was the last torque step below the defined maximum permissible transmission torque, an extrapolation of the torque loss shall be applied up to the maximum torque with linear regression based on the two last measured torque steps for the corresponding speed step. In order to handle engine torque tolerances, etc., the simulation tool will, if required, perform an extrapolation of the torque loss for input torques up to 10 % above said defined maximum permissible transmission torque. 3.4.3. In the case of extrapolation of the torque loss values for maximum input speed and maximum input torque at the same time, the torque loss for the combined point of highest speed and highest torque shall be calculated with two-dimensional linear extrapolation. 3.4.4. If the maximum output torque exceeds 10 kNm (for a theoretical loss free transmission), and/or for all speed and torque points with input power higher than the specified maximum input power, the manufacturer may choose to take the torque loss values for all torques higher than 10 kNm, and/or for all speed and torque points with input power higher than the specified maximum input power, respectively, from one of: (1) Calculated fallback values (Appendix 8) (2) Option 1 (3) Option 2 or 3 in combination with a torque sensor for higher output torques (if required) For cases (i) and (ii) in Option 2, the torque losses at load shall be measured at the input torque that corresponds to output torque 10 kNm and/or the specified maximum input power. 3.4.5. For speeds below the defined minimum speed and the additional input speed step of 0 rpm, the reported torque losses determined for the minimum speed step shall be copied. 3.4.6. To cover the range of negative input torques during vehicle coasting conditions, the torque loss values for positive input torques shall be copied for the related negative input torques. 3.4.7. Upon agreement of an approval authority, the torque losses for the input speeds below 1 000 rpm may be replaced by the torque losses at 1 000 rpm when the measurement is technically not possible. 3.4.8. If the measurement of speed points is technically not possible (e.g. due to natural frequency), the manufacturer may, in agreement with the approval authority, calculate the torque losses by interpolation or extrapolation (limited to max. 1 speed step per gear). 3.4.9. The torque loss map data shall be formatted and saved as specified in Appendix 12 to this Annex. 3.4.1. | In the cases the highest tested input speed was the last speed step below the defined maximum permissible transmission speed, an extrapolation of the torque loss shall be applied up to the maximum speed with linear regression based on the two last measured speed steps. 3.4.2. | In the cases the highest tested input torque was the last torque step below the defined maximum permissible transmission torque, an extrapolation of the torque loss shall be applied up to the maximum torque with linear regression based on the two last measured torque steps for the corresponding speed step. In order to handle engine torque tolerances, etc., the simulation tool will, if required, perform an extrapolation of the torque loss for input torques up to 10 % above said defined maximum permissible transmission torque. 3.4.3. | In the case of extrapolation of the torque loss values for maximum input speed and maximum input torque at the same time, the torque loss for the combined point of highest speed and highest torque shall be calculated with two-dimensional linear extrapolation. 3.4.4. | If the maximum output torque exceeds 10 kNm (for a theoretical loss free transmission), and/or for all speed and torque points with input power higher than the specified maximum input power, the manufacturer may choose to take the torque loss values for all torques higher than 10 kNm, and/or for all speed and torque points with input power higher than the specified maximum input power, respectively, from one of: (1) Calculated fallback values (Appendix 8) (2) Option 1 (3) Option 2 or 3 in combination with a torque sensor for higher output torques (if required) For cases (i) and (ii) in Option 2, the torque losses at load shall be measured at the input torque that corresponds to output torque 10 kNm and/or the specified maximum input power. 3.4.5. | For speeds below the defined minimum speed and the additional input speed step of 0 rpm, the reported torque losses determined for the minimum speed step shall be copied. 3.4.6. | To cover the range of negative input torques during vehicle coasting conditions, the torque loss values for positive input torques shall be copied for the related negative input torques. 3.4.7. | Upon agreement of an approval authority, the torque losses for the input speeds below 1 000 rpm may be replaced by the torque losses at 1 000 rpm when the measurement is technically not possible. 3.4.8. | If the measurement of speed points is technically not possible (e.g. due to natural frequency), the manufacturer may, in agreement with the approval authority, calculate the torque losses by interpolation or extrapolation (limited to max. 1 speed step per gear). 3.4.9. | The torque loss map data shall be formatted and saved as specified in Appendix 12 to this Annex.
4.1.6. Measurement equipmentchanged
The calibration laboratory facilities shall comply with the requirements of either ISO/TS ►M3 IATF ◄ 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards.
4.1.7.2.1. | The input speed npum of the TC shall be fixed to a constant speed within the range of: 1 000 rpm ≤ npum ≤ 2 000 rpm 4.1.7.2.2. | The speed ratio v shall be adjusted by increasing the output speed ntur from 0 rpm up to the set value of npum . 4.1.7.2.3. | The step width shall be 0,1 for the speed ratio range of 0 to 0,6 and 0,05 for the range of 0,6 to 0,95. 4.1.7.2.4. | The upper limit of the speed ratio may be limited to a value below 0,95 by the manufacturer. In this case at least seven evenly distributed points between v = 0 and a value of v < 0,95 have to be covered by the measurement. 4.1.7.2.5. | ►M3 For each step point a minimum of 3 seconds stabilization 3-second stabilisation time within the temperature limits defined in point 4.1.2. is required. ◄ If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. The oil temperature shall be recorded during the stabilization. 4.1.7.2.6. | For each step point the signals specified in 4.1.8. shall be recorded for the test point for 3-15 a minimum of 3 seconds but for no longer than 15 seconds. 4.1.7.2.7. | The measurement sequence (4.1.7.2.1. to 4.1.7.2.6.) shall be performed two times in total.
At least the following signals shall be recorded during the measurement: Input (pump) torque Tc,pum [Nm] Output (turbine) torque Tc,tur [Nm] Input rotational (pump) speed npum [rpm] Output rotational (turbine) speed ntur [rpm] TC input oil temperature KTCin [°C] The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to avoid measurement errors.
The part of the calculated measurement uncertainty UT,pum/tur exceeding 1 % of the measured torque Tc,pum/tur shall be used to correct the characteristic value of the TC as defined below. ΔUT,pum/tur = MAX (0, (UT,pum/tur – 0,01 * Tc,pum/tur)) The uncertainty UT,pum/tur of the torque measurement shall be calculated based on the following parameter: Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The uncertainty UT,pum/tur of the torque measurement is based on the uncertainties of the sensors at 95 % confidence level. where: Tc,pum/tur | = | Current / measured torque value at input/output torque sensor (uncorrected) [Nm] Tpum | = | Input (pump) torque (after uncertainty correction) [Nm] UT,pum/tur | = | Uncertainty of input / output torque measurement at 95 % confidence level separately for input and output torque sensor[Nm] Tn | = | Nominal torque value of torque sensor [Nm] ucal | = | Uncertainty by torque sensor calibration [Nm] Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] kcal | = | Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1)
The retarder drag torque loss is a function of the retarder rotor speed. Since the retarder can be integrated in different parts of the vehicle driveline, the retarder rotor speed depends on the drive part (= speed reference) and step-up ratio between drive part and retarder rotor as shown in Table 2. Table 2 Retarder rotor speeds Configuration | Speed reference | Retarder rotor speed calculation A. Engine Retarder | Engine Speed | nretarder = nengine * istep-up B. Transmission Input Retarder | Transmission Input Shaft Speed | nretarder = ntransm.input * istep-up = ntransm.output * itransm * istep-up ▼M3 C. Transmission Output Retarder or Propshaft Axlegear Input Retarder | Transmission Output Shaft Speed or Axlegear Input Shaft Speed | nretarder = ntransm.output * × istep-up ▼B where: istep-up | = | step-up ratio = retarder rotor speed/drive part speed itransm | = | transmission ratio = transmission input speed/transmission output speed Retarder configurations that are integrated in the engine and cannot be separated from the engine shall be tested in combination with the engine. This section does not cover these non-separable engine integrated retarders. Retarders that can be disconnected from the driveline or the engine by any kind of clutch are considered to have zero rotor speed in disconnected condition and therefore have no power losses. The retarder drag losses shall be measured with one of the following two methods: Measurement on the retarder as a stand-alone unit Measurement in combination with the transmission
7.1. | Every transmission, torque converter (TC), other torque transferring components (OTTC) and additional driveline components (ADC) shall be so manufactured as to conform to the approved type with regard to the description as given in the certificate and its annexes. ►M3 The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out to the conformity of production arrangements laid down in Article 12 31 of Directive 2007/46/EC. Regulation (EU) 2018/858. ◄ 7.2 | Torque converter (TC), other torque transferring components (OTTC) and additional driveline components (ADC) shall be excluded from the production conformity testing provisions of section 8 to this annex. 7.3 | Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificates set out in Appendix 1 to this Annex. 7.4 | Conformity of the certified CO2 emissions and fuel consumption related properties shall be assessed in accordance with the specific conditions laid down in this paragraph. 7.5 | The manufacturer shall test annually at least the number of transmissions indicated in Table 3 based on the total annual production number of the transmissions produced by the manufacturer. For the purpose of establishing the production numbers, only transmissions which fall under the requirements of this Regulation shall be considered. 7.6 | Each transmission which is tested by the manufacturer shall be representative for a specific family. Notwithstanding provisions of the point 7.10., only ►M4 Only one transmission per family shall be tested. ◄ 7.7 | For the total annual production volumes between 1 001 and 10 000 transmissions, the choice of the family for which the tests shall be performed shall be agreed between the manufacturer and the approval authority. 7.8 | For the total annual production volumes above 10 000 transmissions, the transmission family with the highest production volume shall always be tested. The manufacturer shall justify (ex. by showing sales numbers) to the approval authority the number of tests which has been performed and the choice of the families. The remaining families for which the tests are to be performed shall be agreed between the manufacturer and the approval authority. Table 3 Sample size conformity testing Total annual production of transmissions Number of tests 0 – 1 000 0 > 1 000 -10 000 1 > 10 000 -30 000 2 > 30 000 3 > 100 000 4 Total annual production of transmissions | Number of tests 0 – 1 000 | 0 > 1 000 -10 000 | 1 > 10 000 -30 000 | 2 > 30 000 | 3 > 100 000 | 4 7.9. | For the purpose of the conformity of the certified CO2 emissions and fuel consumption related properties testing the approval authority shall identify together with the manufacturer the transmission type(s) to be tested. The approval authority shall ensure that the selected transmission type(s) is manufactured to the same standards as for serial production.. 7.10 | If ►M4 Notwithstanding point 7.6, if the result of a test performed in accordance with point 8 is higher than the one specified in point 8.1.3., 3 three additional transmissions from the same family shall be tested. ◄ If at least one of them fails, provisions of Article 23 shall apply.
8.1.1 | The transmission efficiency shall be determined following the simplified procedure described in this paragraph. 8.1.2.1 All boundary conditions as specified in this Annex for the certification testing shall apply. If other boundary conditions for oil type, oil temperature and inclination angle are used, the manufacturer shall clearly show the influence of these conditions and those used for certification regarding efficiency. 8.1.2.2 For the measurement the same testing option shall be used as for the certification testing, limited to the operating points specified in this paragraph. ▼M3 8.1.2.2.1. In the case Option 1 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured and used for the calculation of the torque losses at the three highest torque steps. points defined in point 2 in 8.1.2.2.2. In the case Option 2 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured. The torque dependent losses at maximum torque shall be measured at the same two speeds. The torque losses at the three highest torque steps points defined in point 2 in 8.1.2.2.2. shall be interpolated as described by the certification procedure. In the case Option 3 was used for certification testing, the torque losses for the 18 operating points defined in 8.1.2.2.2. shall be measured. ▼B 8.1.2.2.2. The efficiency of the transmission shall be determined for 18 operating points defined by the following requirements: (1) Gears to use: The 3 highest gears of the transmission shall be used for testing. ▼M3 (2) Torque range: The In the case Option 1 or 2 was used for certification testing, the following 3 torque points shall be used: 0,6 × max(Tin,rep(inputspeed, gear)), 0,8 × max(Tin,rep(inputspeed, gear)) and max(Tin,rep(inputspeed, gear)) where max(Tin,rep(inputspeed, gear)) is the largest input torque value reported for certification for the combination of input speed and gear in question. In the case Option 3 was used for certification testing, the 3 highest torque steps as reported points that were measured at the certification testing for certification the combination of input speed and gear in question shall be tested. used. ▼B (3) Speed range: The two transmission input speeds of 1 200 rpm and 1 600 rpm shall be tested. ▼M3 8.1.2.3 For each of the 18 operating points, the efficiency of the transmission shall be calculated with: where: η i = Efficiency of each operation point 1 to 18 Tout = Output torque [Nm] Tin Tin,set = Input torque set point value [Nm] nin Tloss,rep = Input speed [rpm] nout = Output speed [rpm] Reported torque loss (after uncertainty correction) [Nm] ▼B 8.1.2.4 The total efficiency during conformity of the certified CO2 emissions and fuel consumption related properties testing ηA,CoP shall be calculated by the arithmetic mean value of the efficiency of all 18 operating points. 8.1.2.1 | All boundary conditions as specified in this Annex for the certification testing shall apply. If other boundary conditions for oil type, oil temperature and inclination angle are used, the manufacturer shall clearly show the influence of these conditions and those used for certification regarding efficiency. 8.1.2.2 | For the measurement the same testing option shall be used as for the certification testing, limited to the operating points specified in this paragraph. ▼M3 8.1.2.2.1. In the case Option 1 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured and used for the calculation of the torque losses at the three highest torque steps. points defined in point 2 in 8.1.2.2.2. In the case Option 2 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured. The torque dependent losses at maximum torque shall be measured at the same two speeds. The torque losses at the three highest torque steps points defined in point 2 in 8.1.2.2.2. shall be interpolated as described by the certification procedure. In the case Option 3 was used for certification testing, the torque losses for the 18 operating points defined in 8.1.2.2.2. shall be measured. ▼B 8.1.2.2.2. The efficiency of the transmission shall be determined for 18 operating points defined by the following requirements: (1) Gears to use: The 3 highest gears of the transmission shall be used for testing. ▼M3 (2) Torque range: The In the case Option 1 or 2 was used for certification testing, the following 3 torque points shall be used: 0,6 × max(Tin,rep(inputspeed, gear)), 0,8 × max(Tin,rep(inputspeed, gear)) and max(Tin,rep(inputspeed, gear)) where max(Tin,rep(inputspeed, gear)) is the largest input torque value reported for certification for the combination of input speed and gear in question. In the case Option 3 was used for certification testing, the 3 highest torque steps as reported points that were measured at the certification testing for certification the combination of input speed and gear in question shall be tested. used. ▼B (3) Speed range: The two transmission input speeds of 1 200 rpm and 1 600 rpm shall be tested. 8.1.2.2.1. | In the case Option 1 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured and used for the calculation of the torque losses at the three highest torque steps. points defined in point 2 in 8.1.2.2.2. In the case Option 2 was used for certification testing, the torque independent losses for the two speeds defined in point 3 of 8.1.2.2.2. shall be measured. The torque dependent losses at maximum torque shall be measured at the same two speeds. The torque losses at the three highest torque steps points defined in point 2 in 8.1.2.2.2. shall be interpolated as described by the certification procedure. In the case Option 3 was used for certification testing, the torque losses for the 18 operating points defined in 8.1.2.2.2. shall be measured. 8.1.2.2.2. | The efficiency of the transmission shall be determined for 18 operating points defined by the following requirements: (1) Gears to use: The 3 highest gears of the transmission shall be used for testing. ▼M3 (2) Torque range: The In the case Option 1 or 2 was used for certification testing, the following 3 torque points shall be used: 0,6 × max(Tin,rep(inputspeed, gear)), 0,8 × max(Tin,rep(inputspeed, gear)) and max(Tin,rep(inputspeed, gear)) where max(Tin,rep(inputspeed, gear)) is the largest input torque value reported for certification for the combination of input speed and gear in question. In the case Option 3 was used for certification testing, the 3 highest torque steps as reported points that were measured at the certification testing for certification the combination of input speed and gear in question shall be tested. used. ▼B (3) Speed range: The two transmission input speeds of 1 200 rpm and 1 600 rpm shall be tested. 8.1.2.3 | For each of the 18 operating points, the efficiency of the transmission shall be calculated with: where: η i = Efficiency of each operation point 1 to 18 Tout = Output torque [Nm] Tin Tin,set = Input torque set point value [Nm] nin Tloss,rep = Input speed [rpm] nout = Output speed [rpm] Reported torque loss (after uncertainty correction) [Nm] η i | = | Efficiency of each operation point 1 to 18 Tout | = | Output torque [Nm] Tin Tin,set | = | Input torque set point value [Nm] nin Tloss,rep | = | Input speed [rpm] nout | = | Output speed [rpm] Reported torque loss (after uncertainty correction) [Nm] 8.1.2.4 | The total efficiency during conformity of the certified CO2 emissions and fuel consumption related properties testing ηA,CoP shall be calculated by the arithmetic mean value of the efficiency of all 18 operating points. 8.1.3 | The conformity of the certified CO2 emissions and fuel consumption related properties test is passed when the following condition applies: The efficiency of the tested transmission during conformity of the certified CO2 emissions and fuel consumption related properties test ηA,CoP shall not be lower than X % of the type approved transmission efficiency ηA,TA . ηA,TA – ηA,CoP ≤ X ▼M1 X shall be replaced by 1,5 % for SMT/AMT/DCT transmissions and 3 % for APT transmissions or transmission with more than 2 friction shift clutches. ▼M3 The efficiency of the approved transmission ηA,TA shall be calculated by the arithmetic mean value of the efficiency of 18 operating points during certification based on the formulas in 8.1.2.3 and 8.1.2.4, defined by the requirements in 8.1.2.2.2. ▼B
2. Definitionschanged
For the purposes of this Annex the following definitions shall apply: ‘Single reduction axle (SR)’ means a driven axle with only one gear reduction, typically a bevel gear set with or without hypoid offset. ‘Single portal axle (SP)’ means an axle, that has typically a vertical offset between the rotating axis of the crown gear and the rotating axis of the wheel due to the demand of a higher ground clearance or a lowered floor to allow a low floor concept for inner city buses. Typically, the first reduction is a bevel gear set, the second one a spur gear set with vertical offset close to the wheels. ‘Hub reduction axle (HR)’ means a driven axle with two gear reductions. The first is typically a bevel gear set with or without hypoid offset. The other is a planetary gear set, what is typically placed in the area of the wheel hubs. ‘Single reduction tandem axle (SRT)’ means a driven axle that is basically similar to a single driven axle, but has also the purpose to transfer torque from the input flange over an output flange to a further axle. The torque can be transferred with a spur gear set close at the input flange to generate a vertical offset for the output flange. Another possibility is to use a second pinion at the bevel gear set, what takes off torque at the crown wheel. ‘Hub reduction tandem axle (HRT)’ means a hub reduction axle, what has the possibility to transfer torque to the rear as described under single reduction tandem axle (SRT). ‘Axle housing’ means the housing parts that are needed for structural capability as well as for carrying the driveline parts, bearings and sealings of the axle. ‘Pinion’ means a part of a bevel gear set which usually consists of two gears. The pinion is the driving gear which is connected with the input flange. In case of a SRT / HRT, a second pinion can be installed to take off torque from the crown wheel. ‘Crown wheel’ means a part of a bevel gear set which usually consists of two gears. The crown wheel is the driven gear and is connected with the differential cage. ‘Hub reduction’ means the planetary gear set that is installed commonly outside the planetary bearing at hub reduction axles. The gear set consists of three different gears. The sun, the planetary gears and the ring gear. The sun is in the centre, the planetary gears are rotating around the sun and are mounted to the planetary carrier that is fixed to the hub. Typically, the number of planetary gears is between three and five. The ring gear is not rotating and fixed to the axle beam. ‘Planetary gear wheels’ means the gears that rotate around the sun within the ring gear of a planetary gear set. They are assembled with bearings on a planetary carrier, what is joined to a hub. ‘Oil type viscosity grade’ means a viscosity grade as defined by SAE J306. ‘Factory fill oil’ means the oil type viscosity grade that is used for the oil fill in the factory and which is intended to stay in the axle for the first service interval. ‘Axle line’ means a group of axles that share the same basic axle-function as defined in the family concept. ‘Axle family’ means a manufacturer's grouping of axles which through their design, as defined in Appendix 4 of this Annex, have similar design characteristics and CO2 and fuel consumption properties. ‘Drag torque’ means the required torque to overcome the inner friction of an axle when the wheel ends are rotating freely with 0 Nm output torque. ‘Mirror inverted axle casing’ means the axle casing is mirrored regarding to the vertical plane. ‘Axle input’ means the side of the axle on which the torque is delivered to the axle. ‘Axle output’ means the side(s) of the axle where the torque is delivered to the wheels.
3. General requirementschanged
The axle gears and all bearings, except bearings shall be new for the verification of axle losses, while wheel end bearings may already be run in and may be used for the measurements, shall not be used. multiple measurements. On request of the applicant different gear ratios can be tested in one axle housing using the same wheel ends. Different axle ratios of hub reduction axles and single portal axles (HR, HRT, SP) may be measured by exchanging the hub reduction only. The provisions as specified in Appendix 4 to this Annex shall apply. The total run-time for the optional run-in and the measurement of an individual axle (except for the axle housing and wheel-ends) shall not exceed 120 hours. For testing the losses of an axle the torque loss map for each ratio of an individual axle shall be measured, however axles can be grouped in axle families following the provisions of Appendix 4 to this Annex.
4.1.3 Oil qualitychanged
Only recommended factory fill oils as specified by the axle manufacturer shall be used for the measurement. ►M3 In the case of testing different gear ratio variants with one axle housing, new oil shall be filled in for each single measurement. measurement of the whole axle system. ◄
4.2.3 Test set-up ‘Type A’changed
A test set-up considered ‘Type A’ consists of a dynamometer on the axle input side and at least one dynamometer on the axle output side(s). Torque measuring devices shall be installed on the axle input- and output- side(s). ►M3 For type A set-ups setups with only one dynamometer on the output side, the free freely rotating end of the axle shall be locked. rotatably locked to the other end on the output side (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). ◄ To avoid parasitic losses, the torque measuring devices shall be positioned as close as possible to the axle input- and output- side(s) being supported by appropriate bearings. Additionally mechanical isolation of the torque sensors from parasitic loads of the shafts, for example by installation of additional bearings and a flexible coupling or lightweight cardan shaft between the sensors and one of these bearings can be applied. ►M3 Figure 1 shows an example for a test test-up setup of Type A in a two dynamometer lay-out. ◄ For Type A test set-up configurations the manufacturer shall provide an analysis of the parasitic loads. Based on this analysis the approval authority shall decide about the maximum influence of parasitic loads. However the value ipara cannot be lower than 10 %.
4.3.1 Measurement equipmentchanged
The calibration laboratory facilities shall comply with the requirements of either ISO/TS ►M3 IATF ◄ 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards.
The following signals shall be recorded for the purpose of the calculation of the torque losses: Input and output torques [Nm] Input and/or output rotational speeds [rpm] Ambient temperature [°C] Oil temperature [°C] Temperature at the torque sensor 4.3.2.1 | The following minimum sampling frequencies of the sensors shall be applied: Torque: 1 kHz Rotational speed: 200 Hz Temperatures: 10 Hz 4.3.2.2 | The recording rate of the data used to determine the arithmetic mean values of each grid point shall be 10 Hz or higher. The raw data do not need to be reported. Signal filtering may be applied in agreement with the approval authority. Any aliasing effect shall be avoided.
4.3.3 Torque range:changed
The extent of the torque loss map to be measured is limited to: 4.3.3.1 | The manufacturer may extend the measurement up to 20 kNm output torque by means of linear extrapolation of torque losses or by performing measurements up to 20 kNm output torque with steps of 2 000 Nm. For this additional torque range another torque sensor at the output side with a maximum torque of 20 kNm (2-machine layout) or two 10 kNm sensors (3-machine layout) shall be used. If the radius of the smallest tire is reduced (e.g. product development) after completing the measurement of an axle or when the physic boundaries of the test stand are reached (e.g. by product development changes), the missing points may be extrapolated by the manufacturer out of the existing map. The extrapolated points shall not exceed more than 10 % of all points in the map and the penalty for these points is 5 % torque loss to be added on the extrapolated points. 4.3.3.2 | Output torque steps to be measured: 250 Nm < Tout < 1 000 Nm : 250 Nm steps 1 000 Nm ≤ Tout ≤ 2 000 Nm : 500 Nm steps 2 000 Nm ≤ Tout ≤ 10 000 Nm : 1 000 Nm steps Tout > 10 000 Nm : 2 000 Nm steps If the maximum input torque is limited by the manufacturer, the last torque step to be measured is the one below this maximum without consideration of any losses. In that case an extrapolation of the torque loss shall be applied up to the torque corresponding to the manufacturer's limitation with the linear regression based on the torque steps of the corresponding speed step. 250 Nm < Tout < 1 000 Nm | : | 250 Nm steps 1 000 Nm ≤ Tout ≤ 2 000 Nm | : | 500 Nm steps 2 000 Nm ≤ Tout ≤ 10 000 Nm | : | 1 000 Nm steps Tout > 10 000 Nm | : | 2 000 Nm steps
4.3.4 Speed rangechanged
The range of test speeds shall comprise from 50 rpm wheel speed to the maximum speed. The maximum test speed to be measured is defined by either the maximum axle input speed or the maximum wheel speed, whichever of the following conditions is reached first: The maximum applicable axle input speed may be limited to design specification of the axle. ►M3 The maximum wheel speed is measured under consideration of the smallest applicable tire diameter at a vehicle speed of 90 km/h for trucks medium and heavy lorries and 110 km/h for coaches. heavy buses. ◄ If the smallest applicable tire diameter is not defined, paragraph 4.3.4.1 shall apply.
The wheel speed step width for testing shall be 50 rpm. rpm for heavy lorries and heavy buses and 100 rpm for medium lorries. It is permitted to measure intermediate speed steps.
►M3 For each speed step the torque loss shall be measured for each output torque step starting from 250 Nm the lowest torque value upward to the maximum and downward to the minimum. ◄ The speed steps can be run in any order. ►M1 The torque measurement sequence shall be performed and recorded twice. ◄ Interruptions of the sequence for cooling or heating purposes are permitted.
4.4.2 Measurement durationchanged
The measurement duration for each single grid point shall be 5-20 a minimum of 5 seconds but no longer than 20 seconds.
The recorded values for each grid point within the 5-20 seconds interval in accordance with point 4.4.2 shall be averaged to an arithmetic mean. All four averaged intervals of corresponding speed and torque grid points from both sequences measured each upward and downward shall be averaged to an arithmetic mean and result into one torque loss value. 4.4.4 | The torque loss (at input side) of the axle shall be calculated by where: Tloss = Torque loss of the axle at the input side [Nm] Tin = Input torque [Nm] igear = Axle gear ratio [-] Tout = Output torque [Nm] Tloss | = | Torque loss of the axle at the input side [Nm] Tin | = | Input torque [Nm] igear | = | Axle gear ratio [-] Tout | = | Output torque [Nm] 4.4.5 | Measurement validation ▼M1 4.4.5.1 The averaged speed values per grid point (5-20 s interval) shall not deviate from the setting values by more than ± 5 rpm for the output speed. ▼B 4.4.5.2 The averaged output torque values as described under 4.4.3 for each grid point shall not deviate more than ± 20 Nm or ± 1 % from the torque set point for the according grid point, whichever is the higher value. 4.4.5.3 If the above specified criteria are not met the measurement is void. In this case, the measurement for the entire affected speed step shall be repeated. After passing the repeated measurement, the data shall be consolidated. 4.4.5.1 | The averaged speed values per grid point (5-20 s interval) shall not deviate from the setting values by more than ± 5 rpm for the output speed. 4.4.5.2 | The averaged output torque values as described under 4.4.3 for each grid point shall not deviate more than ± 20 Nm or ± 1 % from the torque set point for the according grid point, whichever is the higher value. 4.4.5.3 | If the above specified criteria are not met the measurement is void. In this case, the measurement for the entire affected speed step shall be repeated. After passing the repeated measurement, the data shall be consolidated. 4.4.6 | Uncertainty calculationThe total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters: i. Temperature effect ii. Parasitic loads iii. Uncertainty (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The total uncertainty of the torque loss (UT,loss) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done for each applied sensor (e.g. three machine lay out: UT,in, UT,out,1, UTout,2) as the square root of the sum of squares (‘Gaussian law of error propagation’). ▼M3 ————— ▼B wpara = senspara * ipara where: UT,in/out = Uncertainty of input/output torque loss measurement separately for input and output torque; [Nm] igear = Axle gear ratio [-] UTKC = Uncertainty by temperature influence on current torque signal; [Nm] wtkc = Temperature influence on current torque signal per Kref, declared by sensor manufacturer; [%] UTK0 = Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 = Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer; [%] Kref = Reference temperature span for tkc and tk0, declared by sensor manufacturer; [°C] ΔK = Absolute difference in sensor temperature measured at torque sensor between calibration and measurement; If the sensor temperature cannot be measured, a default value of ►M3 ΔK = 15 K ◄ shall be used [°C] Tc = Current/measured torque value at torque sensor; [Nm] Tn = Nominal torque value of torque sensor; [Nm] Ucal = Uncertainty by torque sensor calibration; [Nm] wcal = Relative calibration uncertainty (related to nominal torque); [%] kcal = calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) Upara = Uncertainty by parasitic loads; [Nm] wpara = senspara * ipara Relative influence of forces and bending torques caused by misalignment senspara = Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara = Maximum influence of parasitic loads for specific torque sensor depending on test set-up as indicated in section 4.2.3 and 4.2.4 of this annex. UT,in/out | = | Uncertainty of input/output torque loss measurement separately for input and output torque; [Nm] igear | = | Axle gear ratio [-] UTKC | = | Uncertainty by temperature influence on current torque signal; [Nm] wtkc | = | Temperature influence on current torque signal per Kref, declared by sensor manufacturer; [%] UTK0 | = | Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] wtk0 | = | Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer; [%] Kref | = | Reference temperature span for tkc and tk0, declared by sensor manufacturer; [°C] ΔK | = | Absolute difference in sensor temperature measured at torque sensor between calibration and measurement; If the sensor temperature cannot be measured, a default value of ►M3 ΔK = 15 K ◄ shall be used [°C] Tc | = | Current/measured torque value at torque sensor; [Nm] Tn | = | Nominal torque value of torque sensor; [Nm] Ucal | = | Uncertainty by torque sensor calibration; [Nm] wcal | = | Relative calibration uncertainty (related to nominal torque); [%] kcal | = | calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) Upara | = | Uncertainty by parasitic loads; [Nm] wpara | = | senspara * ipara Relative influence of forces and bending torques caused by misalignment senspara | = | Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % ipara | = | Maximum influence of parasitic loads for specific torque sensor depending on test set-up as indicated in section 4.2.3 and 4.2.4 of this annex. 4.4.7 | Assessment of total uncertainty of the torque lossIn the case the calculated uncertainties UT,in/out are below the following limits, the reported torque loss Tloss,rep shall be regarded as equal to the measured torque loss Tloss . UT,in : 7,5 Nm or 0,25 % of the measured torque, whichever allowed uncertainty value is higher For test setups with one dynamometer on the output side: UT,out : 15 Nm or 0,25 % 0,25% of the measured torque, whichever allowed uncertainty value is higher For test setups with two dynamometers on each output side: UT,out : 7,5 Nm or 0,25% of the measured torque, whichever allowed uncertainty value is higher In the case of higher calculated uncertainties, the part of the calculated uncertainty exceeding the above specified limits shall be added inserted to Tloss for the reported torque loss Tloss,rep as follows: If the limits of UT,in are exceeded: Tloss,rep = Tloss + ΔUTin ΔUT,in = MIN((UT,in – 0,25 % * 0,25% × Tc) or (UT,in – 7,5 Nm)) If limits of UT,out out are exceeded: Tloss,rep = Tloss + ΔUT,out/igear ΔUT,out / igear For test setups with one dynamometer on the output side: ΔUT,out = MIN((UT,out – 0,25 % * 0,25% × Tc) or (UT,out – 15Nm)) For test setups with two dynamometers on each output side: ΔUT,out_1 = MIN((UT,out_1 – 0,25% × Tc) or (UT,out_1 – 7,5Nm)) ΔUT,out_2 = MIN((UT,out_1 – 0,25% × Tc) or (UT,out_1 – 7,5Nm)) where: UT,in/out = Uncertainty of input/output input / output torque loss measurement separately for input and output torque; [Nm] igear = Axle gear ratio [-] ΔUT = The part of the calculated uncertainty exceeding the specified limits UT,in/out | = | Uncertainty of input/output input / output torque loss measurement separately for input and output torque; [Nm] igear | = | Axle gear ratio [-] ΔUT | = | The part of the calculated uncertainty exceeding the specified limits 4.4.8 | Complement of torque loss map data 4.4.8.1 If the torque values exceed the upper range limit linear extrapolation shall be applied. For the extrapolation the slope of linear regression based on all measured torque points for the corresponding speed step shall be applied. ▼M3 4.4.8.2 For the output torque range values below 250 Nm the lowest measured grid point as defined in section 4.3.3.2, the torque loss values of the 250 Nm lowest measured grid point shall be applied. ▼B 4.4.8.3 For 0 rpm wheel speed rpm the torque loss values of the 50 rpm speed step shall be applied. 4.4.8.4 For negative input torques (e.g. overrun, free rolling), the torque loss value measured for the related positive input torque shall be applied. ▼M1 4.4.8.5 In case of a tandem axle, the combined torque loss map for both axles shall be calculated out of the test results for the single axles at the input side. The input torques shall also be added. Tloss,rep,tdm = Tloss,rep, 1 + Tloss,rep, 2 Tin,tdm = Tin, 1 + Tin, 2 ▼B 4.4.8.1 | If the torque values exceed the upper range limit linear extrapolation shall be applied. For the extrapolation the slope of linear regression based on all measured torque points for the corresponding speed step shall be applied. 4.4.8.2 | For the output torque range values below 250 Nm the lowest measured grid point as defined in section 4.3.3.2, the torque loss values of the 250 Nm lowest measured grid point shall be applied. 4.4.8.3 | For 0 rpm wheel speed rpm the torque loss values of the 50 rpm speed step shall be applied. 4.4.8.4 | For negative input torques (e.g. overrun, free rolling), the torque loss value measured for the related positive input torque shall be applied. 4.4.8.5 | In case of a tandem axle, the combined torque loss map for both axles shall be calculated out of the test results for the single axles at the input side. The input torques shall also be added. Tloss,rep,tdm = Tloss,rep, 1 + Tloss,rep, 2 Tin,tdm = Tin, 1 + Tin, 2
5.1. | Every axle type approved in accordance with this Annex shall be so manufactured as to conform, with regard to the description as given in the certification form and its annexes, to the approved type. ►M3 The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out in Article 12 31 of Directive 2007/46/EC. Regulation (EU) 2018/858. ◄ 5.2. | Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificate set out in Appendix 1 to this Annex and the specific conditions laid down in this paragraph. 5.3. | The manufacturer shall test annually at least the number of axles indicated in Table 1 based on the annual production numbers. For the purpose of establishing the production numbers, only axles which fall under the requirements of this Regulation shall be considered. 5.4. | Each axle which is tested by the manufacturer shall be representative for a specific family. 5.5. | The number of families of single reduction (SR) axles and other axles for which the tests shall be conducted is shown in Table 1. Table 1 Sample size for conformity testing Production number Number of test for SR axles Number of tests for other axles than SR axles 0 – 40 000 2 1 40 001 – 50 000 2 2 50 001 – 60 000 3 2 60 001 – 70 000 4 2 70 001 – 80 000 5 2 80 001 and more 5 3 Production number | Number of test for SR axles | Number of tests for other axles than SR axles 0 – 40 000 | 2 | 1 40 001 – 50 000 | 2 | 2 50 001 – 60 000 | 3 | 2 60 001 – 70 000 | 4 | 2 70 001 – 80 000 | 5 | 2 80 001 and more | 5 | 3 5.6. | The two axle families with the highest production volumes shall always be tested. The manufacturer shall justify (e.g. by showing sales numbers) to the approval authority the number of tests which has been performed and the choice of the families. The remaining families for which the tests are to be performed shall be agreed between the manufacturer and the approval authority. 5.7. | For the purpose of the conformity of the certified CO2 emissions and fuel consumption related properties testing the approval authority shall identify together with the manufacturer the axle type(s) to be tested. The approval authority shall ensure that the selected axle type(s) are manufactured according to the same standards as for serial production. 5.8. | If the result of a test performed in accordance with point 6 is higher than the one specified in point 6.4, three additional axles from the same family shall be tested. If at least one of them fails, provisions of Article 23 shall apply.
6.1 | For conformity of the certified CO2 emissions and fuel consumption related properties testing, one of the following methods shall apply upon prior agreement between the approval authority and the applicant for a certificate: (a) Torque loss measurement according to this Annex by following the full procedure limited to the grid points described in 6.2. (b) Torque loss measurement according to this Annex by following the full procedure limited to the grid points described in 6.2, with exception of the run-in procedure. In order to consider the run-in characteristic of an axle, a corrective factor may be applied. This factor shall be determined according to good engineering judgement and with agreement of the approval authority. (c) Measurement of drag torque according to paragraph 6.3. The manufacturer may choose a run-in procedure according to good engineering judgement up to 100 h. 6.2 | If the conformity of the certified CO2 emissions and fuel consumption related properties assessment is performed according to 6.1. a) or b) the grid points for this measurement are limited to 4 grid points from the approved torque loss map. 6.2.1 For that purpose the full torque loss map of the axle to be tested for conformity of the certified CO2 emissions and fuel consumption related properties shall be segmented into three equidistant speed ranges and three torque ranges in order to define nine control areas as shown in figure 2. ▼M1 Figure 2 Speed and torque range for conformity of the certified CO2 emissions and fuel consumption related properties testing ▼B 6.2.2 For four control areas one point shall be selected, measured and evaluated according to the full procedure as described in section 4.4. Each control point shall be selected in the following manner: (i) The control areas shall be selected depending on the axle line: — SR axles including tandem combinations: Control areas 5, 6, 8 and 9 — HR axles including tandem combinations: Control areas 2, 3, 4 and 5 (ii) The selected point shall be located in the centre of the area referring to the speed range and the applicable torque range for the according speed. (iii) In order to have a corresponding point for comparison with the loss map measured for certification, the selected point shall be moved to the closest measured point from the approved map. ►M3 If the selected point is in the middle between two approved points, the higher point shall be used. ◄ 6.2.3 For each measured point of the conformity of the certified CO2 emissions and fuel consumption related properties test and its corresponding point of the type approved map, the efficiency shall be calculated with: where: ηi = Efficiency of the grid point from each single control area 1 to 9 Tout = Output torque [Nm] Tin = Input torque [Nm] iaxle = axle ratio [-] 6.2.4 The average efficiency of the control area shall be calculated as follows: For SR axles: For HR axles: where: ηavr,low speed = average efficiency for low speed ηavr,mid speed = average efficiency for mid speed ηavr,high speed = average efficiency for high speed ηavr,total = simplified averaged efficiency for axle 6.2.5 If the conformity of the certified CO2 emissions and fuel consumption related properties assessment is performed in accordance with 6.1. c), the drag torque of the parent axle of the family to which the tested axle belongs shall be determined during the certification. ►M3 This can be done prior to the run-in procedure or after the run-in procedure according to paragraph in accordance with point 3.1 or by linear extrapolation of all the torque map values for each speed step downwards to 0 Nm. The extrapolation shall be linear or a polynomial second order, depending which standard deviation is lower. ◄ 6.2.1 | For that purpose the full torque loss map of the axle to be tested for conformity of the certified CO2 emissions and fuel consumption related properties shall be segmented into three equidistant speed ranges and three torque ranges in order to define nine control areas as shown in figure 2. ▼M1 Figure 2 Speed and torque range for conformity of the certified CO2 emissions and fuel consumption related properties testing ▼B 6.2.2 | For four control areas one point shall be selected, measured and evaluated according to the full procedure as described in section 4.4. Each control point shall be selected in the following manner: (i) The control areas shall be selected depending on the axle line: — SR axles including tandem combinations: Control areas 5, 6, 8 and 9 — HR axles including tandem combinations: Control areas 2, 3, 4 and 5 (ii) The selected point shall be located in the centre of the area referring to the speed range and the applicable torque range for the according speed. (iii) In order to have a corresponding point for comparison with the loss map measured for certification, the selected point shall be moved to the closest measured point from the approved map. ►M3 If the selected point is in the middle between two approved points, the higher point shall be used. ◄ 6.2.3 | For each measured point of the conformity of the certified CO2 emissions and fuel consumption related properties test and its corresponding point of the type approved map, the efficiency shall be calculated with: where: ηi = Efficiency of the grid point from each single control area 1 to 9 Tout = Output torque [Nm] Tin = Input torque [Nm] iaxle = axle ratio [-] ηi | = | Efficiency of the grid point from each single control area 1 to 9 Tout | = | Output torque [Nm] Tin | = | Input torque [Nm] iaxle | = | axle ratio [-] 6.2.4 | The average efficiency of the control area shall be calculated as follows: For SR axles: For HR axles: where: ηavr,low speed = average efficiency for low speed ηavr,mid speed = average efficiency for mid speed ηavr,high speed = average efficiency for high speed ηavr,total = simplified averaged efficiency for axle ηavr,low speed | = | average efficiency for low speed ηavr,mid speed | = | average efficiency for mid speed ηavr,high speed | = | average efficiency for high speed ηavr,total | = | simplified averaged efficiency for axle 6.2.5 | If the conformity of the certified CO2 emissions and fuel consumption related properties assessment is performed in accordance with 6.1. c), the drag torque of the parent axle of the family to which the tested axle belongs shall be determined during the certification. ►M3 This can be done prior to the run-in procedure or after the run-in procedure according to paragraph in accordance with point 3.1 or by linear extrapolation of all the torque map values for each speed step downwards to 0 Nm. The extrapolation shall be linear or a polynomial second order, depending which standard deviation is lower. ◄ 6.3 | Determination of drag torque 6.3.1 For determination of the drag torque of an axle a simplified test set-up with one electric machine and one torque sensor on the input side is required. ►M3 In the event of a single portal axle with different length of the two output shafts, a test setup with two electric machines and two torque sensors on each output is also permitted. In this respect, both output shafts are driven synchronously in driving direction. The final drag torque is represented by the sum of both output torques. ◄ 6.3.2 The test conditions according to paragraph 4.1 shall apply. The uncertainty calculation regarding torque may be omitted. 6.3.3 The drag torque shall be measured in the speed range of the approved type according to paragraph 4.3.4 under consideration of the speed steps according to 4.3.5. 6.3.1 | For determination of the drag torque of an axle a simplified test set-up with one electric machine and one torque sensor on the input side is required. ►M3 In the event of a single portal axle with different length of the two output shafts, a test setup with two electric machines and two torque sensors on each output is also permitted. In this respect, both output shafts are driven synchronously in driving direction. The final drag torque is represented by the sum of both output torques. ◄ 6.3.2 | The test conditions according to paragraph 4.1 shall apply. The uncertainty calculation regarding torque may be omitted. 6.3.3 | The drag torque shall be measured in the speed range of the approved type according to paragraph 4.3.4 under consideration of the speed steps according to 4.3.5. 6.4. | Conformity of the certified CO2 emissions and fuel consumption related properties test assessment 6.4.1 A conformity of the certified CO2 emissions and fuel consumption related properties test is passed when one of the following conditions apply: ▼M1 (a) If a torque loss measurement in accordance with points 6.1(a) or (b) is conducted, the average efficiency of the tested axle during conformity of the certified CO2 emissions and fuel consumption related properties procedure shall not be lower than 1,5 % for SR axles and 2,0 % for all other axles lines below the corresponding average efficiency of the type approved axle. (b) If a measurement of drag torque in accordance with point 6.1(c) is conducted, the drag torque of the tested axle during conformity of the certified CO2 emissions and fuel consumption related properties procedure shall be lower than the corresponding drag torque of the type approved axle or within the tolerance indicated in Table 2. ▼B ▼M3 Table 2 Axleline Tolerances for axles measured in CoP after run-in Comparison to Td0 Tolerances for axles measured in CoP without run in Comparison to Td0 for i tolerance Td0_input [Nm] for i tolerance Td0_input [Nm] for i tolerance Td0_input Nm] for i tolerance Td0_input [Nm] SR ≤ 3 15 10 > 3 12 ≤ 3 25 9 > 3 20 SRT ≤ 3 16 > 3 13 15 SRT ≤ 3 27 11 > 3 21 10 > 3 18 > 3 16 SP ≤ 6 11 > 6 10 ≤ > 6 18 > 6 16 HR ≤ 7 10 15 > 7 9 12 > 7 25 > 7 20 HRT ≤ 7 16 > 7 15 HRT ≤ 7 11 13 > 7 10 ≤ 7 18 27 > 7 16 21 i = gear ratio. ratio ▼B 6.4.1 | A conformity of the certified CO2 emissions and fuel consumption related properties test is passed when one of the following conditions apply: ▼M1 (a) If a torque loss measurement in accordance with points 6.1(a) or (b) is conducted, the average efficiency of the tested axle during conformity of the certified CO2 emissions and fuel consumption related properties procedure shall not be lower than 1,5 % for SR axles and 2,0 % for all other axles lines below the corresponding average efficiency of the type approved axle. (b) If a measurement of drag torque in accordance with point 6.1(c) is conducted, the drag torque of the tested axle during conformity of the certified CO2 emissions and fuel consumption related properties procedure shall be lower than the corresponding drag torque of the type approved axle or within the tolerance indicated in Table 2. ▼B ▼M3 Table 2 Axleline Tolerances for axles measured in CoP after run-in Comparison to Td0 Tolerances for axles measured in CoP without run in Comparison to Td0 for i tolerance Td0_input [Nm] for i tolerance Td0_input [Nm] for i tolerance Td0_input Nm] for i tolerance Td0_input [Nm] SR ≤ 3 15 10 > 3 12 ≤ 3 25 9 > 3 20 SRT ≤ 3 16 > 3 13 15 SRT ≤ 3 27 11 > 3 21 10 > 3 18 > 3 16 SP ≤ 6 11 > 6 10 ≤ > 6 18 > 6 16 HR ≤ 7 10 15 > 7 9 12 > 7 25 > 7 20 HRT ≤ 7 16 > 7 15 HRT ≤ 7 11 13 > 7 10 ≤ 7 18 27 > 7 16 21 i = gear ratio. ratio ▼B Axleline | Tolerances for axles measured in CoP after run-in Comparison to Td0 | Tolerances for axles measured in CoP without run in Comparison to Td0 for i | tolerance Td0_input [Nm] | for i | tolerance Td0_input [Nm] | for i | tolerance Td0_input Nm] | for i | tolerance Td0_input [Nm] SR | ≤ 3 | 15 10 | > 3 | 12 | ≤ 3 | 25 9 | > 3 | 20 SRT | ≤ 3 | 16 | > 3 | 13 15 SRT | ≤ 3 | 27 11 | > 3 | 21 10 | > 3 | 18 | > 3 | 16 SP | ≤ 6 | 11 | > 6 | 10 | ≤ > 6 | 18 | > 6 | 16 HR | ≤ 7 | 10 15 | > 7 | 9 12 | > 7 | 25 | > 7 | 20 HRT | ≤ 7 | 16 | > 7 | 15 HRT | ≤ 7 | 11 13 | > 7 | 10 | ≤ 7 | 18 27 | > 7 | 16 21 i | = | gear ratio. ratio
1. Introductionchanged
This Annex sets out the test procedure procedures for verifying the determination of air drag data.
2. Definitionschanged
For the purposes of this Annex the following definitions shall apply: ‘Active aero device’ means measures which are activated by a control unit to reduce the air drag of the total vehicle. ‘Aero accessories’ mean optional devices which have the purpose to influence the air flow around the total vehicle. ‘A-pillar’ means the connection by a supporting structure between the cabin roof and the front bulkhead. ‘Body in white geometry’ means the supporting structure incl. the windshield of the cabin. ‘B-pillar’ means the connection by a supporting structure between the cabin floor and the cabin roof in the middle of the cabin. ‘Cab bottom’ means the supporting structure of the cabin floor. ‘Cabin over frame’ means distance from frame to cabin reference point in vertical Z. Distance is measured from top of horizontal frame to cabin reference point in vertical Z. ‘Cabin reference point’ means the reference point (X/Y/Z = 0/0/0) from the CAD coordinate system of the cabin or a clearly defined point of the cabin package e.g. heel point. ‘Cabin width’ means the horizontal distance of the left and right B-pillar of the cabin. ‘Constant speed test’ means measurement procedure to be carried out on a test track in order to determine the air drag. ‘Dataset’ means the data recorded during a single passing of a measurement section. ‘EMS’ means the European Modular System (EMS) in accordance with Council Directive 96/53/EC. ‘Frame height’ means distance of wheel center to top of horizontal frame in Z. ‘Heel point’ means the point which is representing the heel of shoe location on the depressed floor covering, when the bottom of shoe is in contact with the undepressed accelerator pedal and the ankle angle is at 87°. (ISO 20176:2011) ‘Measurement area(s)’ means designated part(s) of the test track consisting of at least one measurement section and a preceded stabilisation section. ‘Measurement section’ means a designated part of the test track which is relevant for data recording and data evaluation. ‘Roof height’ means distance in vertical Z from cabin reference point to highest point of roof w/o sunroof
3. Determination of air dragchanged
The constant speed test procedure as set out in points 3.1 to 3.7 shall be applied to determine the air drag characteristics. During the constant speed test test, the main measurement signals driving torque, vehicle speed, air flow velocity and yaw angle shall be measured at two different constant vehicle speeds (low and high speed) under defined conditions on a test track. The measurement data recorded during the constant speed test shall be processed in accordance with point 3.8 and entered into the air drag pre-processing tool in accordance with point 3.9 which determines product of drag coefficient by cross sectional area for zero crosswind conditions Cd · Acr (0) as input for the simulation tool. The applicant for a certificate shall declare a value Cd · Adeclared in a range from equal up to a maximum of + 0,2 m2 higher than Cd · Acr Cd·Acr (0). The value Cd · Adeclared criteria that shall be met during the input for the simulation tool CO2 simulation tool and the reference value for conformity of the certified CO2 emissions and fuel consumption related properties testing. Vehicles which constant speed test procedure to obtain valid results are not member of a family shall use the standard values for Cd·Adeclared as described in Appendix 7 to point 3.10. Air drag characteristics may also be determined by combining the Cd·Acr (0) from a constant speed test with an incremental difference ΔCd·Acr(0) CFD obtained by means of CFD. For this Annex. In this case no input data on air drag purpose, the following requirements shall be provided. The allocation of standard values is done automatically by the simulation tool. met:
3.2.1. | The ambient conditions shall be measured with the equipment specified in 3.4. 3.2.2. | ►M4 The ambient temperature shall be in the range of 0 5 °C to 25 °C. ◄ This criterion is checked by the air drag pre-processing tool based on the signal for ambient temperature measured on the vehicle. This criterion only applies to the datasets recorded in the low speed - high speed – low speed sequence and not to the misalignment test and the warm-up phases. 3.2.3. | The ground temperature shall not exceed 40 °C. This criterion is checked by the air drag pre-processing tool based on the signal for ground temperature measured on the vehicle by an IR Sensor. This criterion only applies to the datasets recorded in the low speed - high speed – low speed sequence and not to the misalignment test and the warm-up phases. 3.2.4. | The road surface shall be dry during the low speed – high speed - low speed sequence to provide comparable rolling resistance coefficients. 3.2.5. | The wind conditions shall be within the following range: ▼M4 i. Average wind speed: ≤ 5 4 m/s ii. Gust wind speed (1s central moving average): ≤ 8 7 m/s Items i. and ii. are applicable for the datasets recorded in the high speed test and the misalignment calibration test but not for the low speed tests. ▼B iii. Average yaw angle (β): ≤ 3 degrees for datasets recorded in the high speed test ≤ 5 degrees for datasets recorded during misalignment calibration test The validity of wind conditions is checked by the air drag pre-processing based on the signals recorded at the vehicle after application of the boundary layer correction. Measurement data collected under conditions exceeding the above named limits are automatically excluded from the calculation. 3.3. | Installation of the vehicle 3.3.1. General installation requirements 3.3.1.1. The vehicle tested shall represent the vehicle to be placed on the market, in accordance with the requirements for vehicle type approval in accordance with Regulation (EU) 2018/858. Equipment which is necessary to execute the constant speed test (e.g. overall vehicle height including anemometer) is excluded from this provision. 3.3.1.2. The vehicle shall be equipped with tyres meeting the following criteria: — Best or second best label for fuel efficiency which is available at the moment the test is performed; — Maximum tread depth of 10 mm on all tyres of the complete vehicle, including the trailer (if applicable); — Tyres inflated within a tolerance of ± 20 kPa of the pressure marked on the tyre sidewall in accordance with Article 3 of UN Regulation No. 54 ( 16 ). 3.3.1.3. The axle alignment shall be within the manufacturer’s specifications. 3.3.1.4. No active tyre pressure control systems are allowed to be used during the measurements of the low speed - high speed - low speed tests. 3.3.1.5. If the vehicle is equipped with an active aero device, the device may be active during the constant speed test under the following conditions: — it has been demonstrated to the approval authority that the device is always activated and effective to reduce the air drag at vehicle speeds higher than 60 km/h for medium and heavy lorries and higher than 80 km/h for heavy buses; — the device is installed and effective in a similar manner on all vehicles of the family. In all other cases the active aero device has to be fully deactivated during the constant speed test. 3.3.1.6. The vehicle shall not be equipped with any provisional features, modifications or devices that are not representative for the vehicle in use, aimed to reducing the air drag value during the test (e.g. sealed bodywork gaps). Modifications which aim to align the aerodynamic characteristics of the tested vehicle to the specifications of the parent vehicle are allowed. ▼M4 3.3.1.7. Aftermarket parts which are not covered by the vehicle type approval in accordance with Regulation (EU) 2018/858 (e.g. sun visors, horns, additional head lights, signal lights, bull bars or ski-boxes) are not considered for the air drag in accordance with this Annex. ▼M3 3.3.1.8. The vehicle shall be measured without payload. ▼M4 3.3.1.9. Vehicle equipment designed for the purpose of dynamic charging as defined in point 3(38) of Annex III shall be set in the ‘retracted’ state if both ‘extended’ and ‘retracted’ states are possible. ▼M3 3.3.2. Installation requirements applicable for medium and heavy rigid lorries 3.3.2.1. The vehicle chassis shall fit to the dimensions of the standard body or semi-trailer as defined in Appendix 4 of this Annex. 3.3.2.2. The vehicle height determined in accordance with 3.5.3.1 item vii shall be within the limits as specified in Appendix 3 of this Annex. 3.3.2.3. The minimum distance between the cabin and the box body or semi-trailer shall be in accordance with the manufacturer’s requirements and body builder’s instructions. 3.3.2.4. The cabin and the aero accessories shall be adapted to best fit to the defined standard body or semi-trailer. The installation of the aero accessories (e.g. spoiler) shall be in accordance with the instructions of the manufacturer. 3.3.2.5. The setup of the semi-trailer shall be as defined in Appendix 4 of this Annex. 3.3.1. | General installation requirements 3.3.1.1. The vehicle tested shall represent the vehicle to be placed on the market, in accordance with the requirements for vehicle type approval in accordance with Regulation (EU) 2018/858. Equipment which is necessary to execute the constant speed test (e.g. overall vehicle height including anemometer) is excluded from this provision. 3.3.1.2. The vehicle shall be equipped with tyres meeting the following criteria: — Best or second best label for fuel efficiency which is available at the moment the test is performed; — Maximum tread depth of 10 mm on all tyres of the complete vehicle, including the trailer (if applicable); — Tyres inflated within a tolerance of ± 20 kPa of the pressure marked on the tyre sidewall in accordance with Article 3 of UN Regulation No. 54 ( 16 ). 3.3.1.3. The axle alignment shall be within the manufacturer’s specifications. 3.3.1.4. No active tyre pressure control systems are allowed to be used during the measurements of the low speed - high speed - low speed tests. 3.3.1.5. If the vehicle is equipped with an active aero device, the device may be active during the constant speed test under the following conditions: — it has been demonstrated to the approval authority that the device is always activated and effective to reduce the air drag at vehicle speeds higher than 60 km/h for medium and heavy lorries and higher than 80 km/h for heavy buses; — the device is installed and effective in a similar manner on all vehicles of the family. In all other cases the active aero device has to be fully deactivated during the constant speed test. 3.3.1.6. The vehicle shall not be equipped with any provisional features, modifications or devices that are not representative for the vehicle in use, aimed to reducing the air drag value during the test (e.g. sealed bodywork gaps). Modifications which aim to align the aerodynamic characteristics of the tested vehicle to the specifications of the parent vehicle are allowed. ▼M4 3.3.1.7. Aftermarket parts which are not covered by the vehicle type approval in accordance with Regulation (EU) 2018/858 (e.g. sun visors, horns, additional head lights, signal lights, bull bars or ski-boxes) are not considered for the air drag in accordance with this Annex. ▼M3 3.3.1.8. The vehicle shall be measured without payload. ▼M4 3.3.1.9. Vehicle equipment designed for the purpose of dynamic charging as defined in point 3(38) of Annex III shall be set in the ‘retracted’ state if both ‘extended’ and ‘retracted’ states are possible. ▼M3 3.3.1.1. | The vehicle tested shall represent the vehicle to be placed on the market, in accordance with the requirements for vehicle type approval in accordance with Regulation (EU) 2018/858. Equipment which is necessary to execute the constant speed test (e.g. overall vehicle height including anemometer) is excluded from this provision. 3.3.1.2. | The vehicle shall be equipped with tyres meeting the following criteria: — Best or second best label for fuel efficiency which is available at the moment the test is performed; — Maximum tread depth of 10 mm on all tyres of the complete vehicle, including the trailer (if applicable); — Tyres inflated within a tolerance of ± 20 kPa of the pressure marked on the tyre sidewall in accordance with Article 3 of UN Regulation No. 54 ( 16 ). 3.3.1.3. | The axle alignment shall be within the manufacturer’s specifications. 3.3.1.4. | No active tyre pressure control systems are allowed to be used during the measurements of the low speed - high speed - low speed tests. 3.3.1.5. | If the vehicle is equipped with an active aero device, the device may be active during the constant speed test under the following conditions: — it has been demonstrated to the approval authority that the device is always activated and effective to reduce the air drag at vehicle speeds higher than 60 km/h for medium and heavy lorries and higher than 80 km/h for heavy buses; — the device is installed and effective in a similar manner on all vehicles of the family. In all other cases the active aero device has to be fully deactivated during the constant speed test. 3.3.1.6. | The vehicle shall not be equipped with any provisional features, modifications or devices that are not representative for the vehicle in use, aimed to reducing the air drag value during the test (e.g. sealed bodywork gaps). Modifications which aim to align the aerodynamic characteristics of the tested vehicle to the specifications of the parent vehicle are allowed. 3.3.1.7. | Aftermarket parts which are not covered by the vehicle type approval in accordance with Regulation (EU) 2018/858 (e.g. sun visors, horns, additional head lights, signal lights, bull bars or ski-boxes) are not considered for the air drag in accordance with this Annex. 3.3.1.8. | The vehicle shall be measured without payload. 3.3.1.9. | Vehicle equipment designed for the purpose of dynamic charging as defined in point 3(38) of Annex III shall be set in the ‘retracted’ state if both ‘extended’ and ‘retracted’ states are possible. 3.3.2. | Installation requirements applicable for medium and heavy rigid lorries 3.3.2.1. The vehicle chassis shall fit to the dimensions of the standard body or semi-trailer as defined in Appendix 4 of this Annex. 3.3.2.2. The vehicle height determined in accordance with 3.5.3.1 item vii shall be within the limits as specified in Appendix 3 of this Annex. 3.3.2.3. The minimum distance between the cabin and the box body or semi-trailer shall be in accordance with the manufacturer’s requirements and body builder’s instructions. 3.3.2.4. The cabin and the aero accessories shall be adapted to best fit to the defined standard body or semi-trailer. The installation of the aero accessories (e.g. spoiler) shall be in accordance with the instructions of the manufacturer. 3.3.2.5. The setup of the semi-trailer shall be as defined in Appendix 4 of this Annex. 3.3.2.1. | The vehicle chassis shall fit to the dimensions of the standard body or semi-trailer as defined in Appendix 4 of this Annex. 3.3.2.2. | The vehicle height determined in accordance with 3.5.3.1 item vii shall be within the limits as specified in Appendix 3 of this Annex. 3.3.2.3. | The minimum distance between the cabin and the box body or semi-trailer shall be in accordance with the manufacturer’s requirements and body builder’s instructions. 3.3.2.4. | The cabin and the aero accessories shall be adapted to best fit to the defined standard body or semi-trailer. The installation of the aero accessories (e.g. spoiler) shall be in accordance with the instructions of the manufacturer. 3.3.2.5. | The setup of the semi-trailer shall be as defined in Appendix 4 of this Annex. 3.4. | Measurement equipmentThe calibration laboratory shall comply with the requirements of either ►M3 IATF ◄ 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards. 3.4.1. Torque 3.4.1.1. The direct torque at all driven axles shall be measured with one of the following measurement systems: a. Hub torque meter b. Rim torque meter c. Half shaft torque meter ▼M3 3.4.1.2. The following system requirements shall be met by a single torque meter by calibration: (i) Non linearity: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (ii) Repeatability: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (iii) Crosstalk: < ± 10 Nm for heavy lorries and heavy buses < ± 8 Nm for medium lorries (only applicable for rim torque meters); (iv) Measurement rate: ≥ 20 Hz where: ‘Non linearity’ means the maximum deviation between ideal and actual output signal characteristics in relation to the measurand in a specific measuring range. ‘Repeatability’ means closeness of the agreement between the results of successive measurements of the same measurand carried out under the same conditions of measurement. ‘Crosstalk’ means signal at the main output of a sensor (My), produced by a measurand (Fz) acting on the sensor, which is different from the measurand assigned to this output. Coordinate system assignment is defined in accordance with ISO 4130. The recorded torque data shall be corrected for the instrument error determined by the supplier. ▼B 3.4.2. Vehicle speed The vehicle speed is determined by the air drag pre-processing tool based on the CAN-bus front axle signal which is calibrated based on either: Option (a) : a reference speed calculated by a delta-time from two fixed opto-electronic barriers (see 3.4.4 of this Annex) and the known length(s) of the measurement section(s) or Option (b) : a delta-time determined speed signal from the position signal of a DGPS and the known length(s) of the measurement section(s), derived by the DGPS coordinates For the vehicle speed calibration the data recorded during the high speed test are used. ▼M3 3.4.3. Reference signal for calculation of rotational speed of the wheels at the driven axle One out of three options shall be selected: Option 1: Engine speed based The CAN engine speed signal together with the transmission ratios (gears for low speed test and high speed test, axle ratio) shall be made available. For the CAN engine speed signal it shall be demonstrated that the signal provided to the air drag pre-processing tool is identical to the signal to be used for in-service testing as set out in Annex I to Regulation (EU) 582/2011. For vehicles with torque converter which are not able to drive the low speed test with closed lockup clutch in option 1, additionally the cardan shaft speed signal and the axle ratio or the average wheel speed signal for the driven axle shall be provided to the air drag pre-processing tool. It shall be demonstrated that the engine speed calculated from this additional signal is within 1 % range compared to the CAN engine speed. This shall be demonstrated for the average value over a measurement section driven at the lowest possible vehicle speed in the torque converter locked mode and at the applicable vehicle speed for the high speed test. Option 2: Wheel speed based The average of the CAN signals for the rotational speed of left and right wheel at the driven axle shall be made available. Alternatively external sensors may be used. Any method shall fulfill the requirements set out in Table 2 of Annex Xa. Following option 2 the input parameters for gear ratios and axle ratio shall be set to 1, independent of the powertrain configuration. Option 3: Electric motor speed based In the case of hybrid and fully electric vehicles, the CAN electric motor speed signal together with the transmission ratios (gears for low speed test and high speed test and if applicable axle ratio) shall be made available. It shall be demonstrated that the wheel speed of the driven axle in the low and high speed test is defined solely by these powertrain configuration specifications. ▼B 3.4.4. Opto-electronic barriers The signal of the barriers shall be made available to the air drag pre-processing tool for triggering begin and end of the measurement section and the calibration of the vehicle speed signal. The measurement rate of the trigger signal shall be greater or equal to 100 Hz. Alternatively a DGPS system can be used. 3.4.5. (D)GPS system Option a) for position measurement only: GPS Required accuracy: i. Position: < 3 m 95 % Circular Error Probable ii. Update rate: ≥ 4 Hz Option b) for vehicle speed calibration and position measurement: Differential GPS system (DGPS) Required accuracy: i. Position: 0,15 m 95 % Circular Error Probable ii. Update rate: ≥ 100 Hz 3.4.6. Stationary weather station Ambient pressure and humidity of the ambient air are determined from a stationary weather station. This meteorological instrumentation shall be positioned in a distance less than 2 000 m to one of the measurement areas, and shall be positioned at an altitude exceeding or equal that of the measurement areas. Required accuracy: i. Temperature: ± 1 °C ii. Humidity: ± 5 % RH iii. Pressure: ± 1 mbar iv. Update rate: ≤ 6 minutes 3.4.7. Mobile anemometer A mobile anemometer shall be used to measure air flow conditions, i.e. air flow velocity and yaw angle (β) between total air flow and vehicle longitudinal axis. 3.4.7.1. Accuracy requirements The anemometer shall be calibrated in facility according to ISO 16622. The accuracy requirements according to Table 1 have to be fulfilled: Table 1 Anemometer accuracy requirements Air speed range [m/s] Accuracy air speed [m/s] Accuracy yaw angle in yaw angle range of 180 ± 7 degrees [degrees] 20 ± 1 ± 0,7 ± 1,0 27 ± 1 ± 0,9 ± 1,0 35 ± 1 ± 1,2 ± 1,0 ▼M3 3.4.7.2. Installation position The mobile anemometer shall be installed on the vehicle in the prescribed position: (i) X position: Medium and heavy rigid lorries and tractors: front face ± 0,3 m of the semi-trailer or box-body; Heavy buses: Between the end of the front quarter of the vehicle and the rear end of the vehicle. Medium van lorries: between B-Pillar up to the rear end of the vehicle. (ii) Y position: plane of symmetry within a tolerance ± 0,1 m; (iii) Z position: The installation height above the vehicle shall be one third of the total vehicle height measured from the ground within a tolerance of 0,0 m to + 0,2 m For vehicles with a total vehicle height above 4 m, on request of the manufacturer the installation height above the vehicle can be limited to 1,3 m, with a tolerance of 0,0 m to + 0,2 m. The instrumentation shall be done as accurate as possible using geometrical or optical aids. Any remaining misalignment is subject to the misalignment calibration to be performed in accordance with 3.6 of this Annex. ▼B 3.4.7.3. The update rate of the anemometer shall be 4 Hz or higher. 3.4.8. Temperature transducer for ambient temperature on vehicle The ambient air temperature shall be measured on the pole of the mobile anemometer. The installation height shall be maximum 600 mm below the mobile anemometer. The sensor shall be shielded to the sun. Required accuracy: ± 1 °C Update rate: ≥ 1 Hz 3.4.9. Proving ground temperature The temperature of the proving ground shall be recorded on vehicle by means of a contactless IR sensor by wideband (8 to 14 μm). For tarmac and concrete an emissivity factor of 0,90 shall be used. ►M3 The IR sensor shall be calibrated in accordance with ASTM E2847 or VDI/VDE 3511. ◄ Required accuracy at calibration: Temperature: ± 2,5 °C Update rate: ≥ 1 Hz 3.4.1.1. | The direct torque at all driven axles shall be measured with one of the following measurement systems: a. Hub torque meter b. Rim torque meter c. Half shaft torque meter 3.4.1.2. | The following system requirements shall be met by a single torque meter by calibration: (i) Non linearity: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (ii) Repeatability: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (iii) Crosstalk: < ± 10 Nm for heavy lorries and heavy buses < ± 8 Nm for medium lorries (only applicable for rim torque meters); (iv) Measurement rate: ≥ 20 Hz where: ‘Non linearity’ means the maximum deviation between ideal and actual output signal characteristics in relation to the measurand in a specific measuring range. ‘Repeatability’ means closeness of the agreement between the results of successive measurements of the same measurand carried out under the same conditions of measurement. ‘Crosstalk’ means signal at the main output of a sensor (My), produced by a measurand (Fz) acting on the sensor, which is different from the measurand assigned to this output. Coordinate system assignment is defined in accordance with ISO 4130. The recorded torque data shall be corrected for the instrument error determined by the supplier. (i) | Non linearity: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (ii) | Repeatability: < ± 6 Nm for heavy lorries and heavy buses < ± 5 Nm for medium lorries; (iii) | Crosstalk: < ± 10 Nm for heavy lorries and heavy buses < ± 8 Nm for medium lorries (only applicable for rim torque meters); (iv) | Measurement rate: ≥ 20 Hz Option (a) | : | a reference speed calculated by a delta-time from two fixed opto-electronic barriers (see 3.4.4 of this Annex) and the known length(s) of the measurement section(s) or Option (b) | : | a delta-time determined speed signal from the position signal of a DGPS and the known length(s) of the measurement section(s), derived by the DGPS coordinates i. | Position: < 3 m 95 % Circular Error Probable ii. | Update rate: ≥ 4 Hz i. | Position: 0,15 m 95 % Circular Error Probable ii. | Update rate: ≥ 100 Hz i. | Temperature: ± 1 °C ii. | Humidity: ± 5 % RH iii. | Pressure: ± 1 mbar iv. | Update rate: ≤ 6 minutes Air speed range [m/s] | Accuracy air speed [m/s] | Accuracy yaw angle in yaw angle range of 180 ± 7 degrees [degrees] 20 ± 1 | ± 0,7 | ± 1,0 27 ± 1 | ± 0,9 | ± 1,0 35 ± 1 | ± 1,2 | ± 1,0 3.4.7.3. | The update rate of the anemometer shall be 4 Hz or higher. 3.5. | Constant speed test procedureOn each applicable combination of measurement section and driving direction the constant speed test procedure consisting of the low speed, high speed and low speed test sequence as specified below shall be performed in the same direction. 3.5.1. The average speed within a measurement section in the low speed test shall be a in the range of 10 to 15 km/h. ▼M4 3.5.2. The average speed within a measurement section in the high speed test shall be in the following range: maximum speed: 92 km/h for medium and heavy lorries and 102 km/h for heavy buses; minimum speed: 87 km/h for medium and heavy lorries and 97 km/h for heavy buses. If the vehicle is not able to run at such speed, the minimum speed shall be equal to 3 km/h less than the maximum vehicle speed the vehicle can be operated at the test track. ▼B 3.5.3. The testing shall be performed strictly according to the sequence as specified in 3.5.3.1 to 3.5.3.9 of this Annex. 3.5.3.1. Preparation of vehicle and measurement systems (i) Installation of torque meters on the driven axles of the test vehicle and check of installation and signal data according to the manufacturer specification. (ii) Documentation of relevant general vehicle data for the official testing template in accordance with 3.7 of this Annex. (iii) For the calculation of the acceleration correction by the air drag pre-processing tool the actual vehicle weight shall be determined before the test within a range of ± 500 kg. (iv) Check of tyres for the maximum allowable inflation pressure and documentation of tyre pressure values. (v) Preparation of opto-electronic barriers at the measurement section(s) or check of proper function of the DGPS system. (vi) Installation of mobile anemometer on the vehicle and/or control of the installation, position and orientation. ►M3 A misalignment calibration test has to be performed every time the anemometer has been mounted newly on the vehicle or has been adjusted. ◄ ▼M3 (vii) Check of vehicle setup regarding the height and geometry, in standard ride height position: — Medium and heavy rigid lorries and tractors: the maximum height of the vehicle shall be determined by measuring at the four corners of the box body/semi-trailer. ▼M4 — Heavy buses and medium lorries of van chassis configuration: the maximum height of the vehicle shall be measured in accordance with the technical requirements of Regulation (EU) 2021/535, by not taking into account the devices and equipment referred to in Appendix 1. ▼B (viii) Adjustment the height of the semi-trailer to the target value and redo determination of maximum vehicle height if necessary. (ix) Mirrors or optical systems, roof fairing or other aerodynamic devices shall be in their regular driving condition. 3.5.3.2. Warm-up phase Drive the vehicle minimum 90 minutes at the target speed of the high speed test to warm-up the system. A repeated warm up (e.g. after a configuration change, an invalid test etc.) shall be at least as long as the standstill time. The warm-up phase can be used to perform the misalignment calibration test as specified in 3.6 of this Annex. ▼M1 In case it is not possible to maintain high speed for a complete round, e.g. due to curves being too narrow, it is allowed to deviate from target speed requirement during the curves, including the nearby straight portions that are needed for slowing down and accelerating the vehicle. Deviations shall be minimized as far as possible. Alternatively, the warm-up phase may be performed on a nearby road, if the target speed is maintained within ± 10 km/h for 90 % of the warm-up time. The part of the warm-up phase used for driving from the road to the standstill area of the test track for zeroing of the torque meters shall be included in the other warm-up phase set out in point 3.5.3.4. The time for this part shall not exceed 20 minutes. The speed and time during the warm-up phase shall be recorded by the measurement equipment. ▼B 3.5.3.3. Zeroing of torque meters The zeroing of the torque meters shall be performed as follows: i. Bring the vehicle to a standstill ii. Lift the instrumented wheels off the ground iii. Perform the zeroing of the amplifier reading of the torque meters ▼M3 The standstill phase shall not exceed 15 minutes. ▼M1 3.5.3.4. Drive another warm-up phase of minimum 10 minutes plus, if applicable, the driving from the road to the standstill area of the test track for zeroing of the torque meters at the target speed of the high speed test. ►M3 The warm-up phase in accordance with this point shall not be shorter than the standstill phase and not exceed 30 minutes. ◄ ▼M4 Any usage of the mechanical service brake during the parts of the test set out in this point and in point 3.5.3.5 invalidates the whole test. If specific vehicle settings are required to ensure that no activation of the service brake occurs during these parts, the manufacturer shall provide, upon request, the approval authority, the Commission, a market surveillance authority or a third party complying with the requirements of Regulation (EU) 2022/163 with the details of these settings to ensure that the test may be reproduced independently from the manufacturer. ▼B 3.5.3.5. First low speed testPerform the first measurement at low speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.1 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. driving at the parts of the test track outside the measurement sections and the preceding stabilisation sections shall be performed without any delay. Any unnecessary manoeuvres shall be avoided during these phases (e.g. driving in sinuous lines) ▼M4 vii. the maximum time for the low speed test shall not exceed 25 minutes in order to prevent cool down of the tyres ▼M4 ————— ▼B 3.5.3.6. Drive another warm-up phase of minimum 5 minutes at the target speed of the high speed test. 3.5.3.7. High speed testPerform the measurement at the high speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.2 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. in the driving phases outside the measurement sections and the preceding stabilization sections any unnecessary manoeuvres shall be avoided (e.g. driving in sinuous lines, unnecessary accelerations or decelerations) vii. the distance between the measured vehicle to another driven vehicle on the test track shall be at least 500 m. viii. at least 10 valid passings per heading are recorded The high speed test can be used to determine the misalignment of the anemometer if the provisions stated in 3.6 are fulfilled. ▼M4 3.5.3.8. Second low speed testPerform the second measurement at the low speed directly after the high speed test. The same provisions as for the first low speed test shall be fulfilled. ▼B 3.5.3.9. Drift check of torque metersDirectly after the finalisation of the second low speed test the drift check of the torque meters shall be performed in accordance to the following procedure: 1. Bring the vehicle to standstill 2. Lift the instrumented wheels off the ground 3. The drift of each torque meter calculated from the average of the minimum sequence of 10 seconds shall be less than 25 Nm. Exceeding this limit leads to an invalid test. 3.5.1. | The average speed within a measurement section in the low speed test shall be a in the range of 10 to 15 km/h. 3.5.2. | The average speed within a measurement section in the high speed test shall be in the following range: maximum speed: 92 km/h for medium and heavy lorries and 102 km/h for heavy buses; minimum speed: 87 km/h for medium and heavy lorries and 97 km/h for heavy buses. If the vehicle is not able to run at such speed, the minimum speed shall be equal to 3 km/h less than the maximum vehicle speed the vehicle can be operated at the test track. 3.5.3. | The testing shall be performed strictly according to the sequence as specified in 3.5.3.1 to 3.5.3.9 of this Annex. 3.5.3.1. Preparation of vehicle and measurement systems (i) Installation of torque meters on the driven axles of the test vehicle and check of installation and signal data according to the manufacturer specification. (ii) Documentation of relevant general vehicle data for the official testing template in accordance with 3.7 of this Annex. (iii) For the calculation of the acceleration correction by the air drag pre-processing tool the actual vehicle weight shall be determined before the test within a range of ± 500 kg. (iv) Check of tyres for the maximum allowable inflation pressure and documentation of tyre pressure values. (v) Preparation of opto-electronic barriers at the measurement section(s) or check of proper function of the DGPS system. (vi) Installation of mobile anemometer on the vehicle and/or control of the installation, position and orientation. ►M3 A misalignment calibration test has to be performed every time the anemometer has been mounted newly on the vehicle or has been adjusted. ◄ ▼M3 (vii) Check of vehicle setup regarding the height and geometry, in standard ride height position: — Medium and heavy rigid lorries and tractors: the maximum height of the vehicle shall be determined by measuring at the four corners of the box body/semi-trailer. ▼M4 — Heavy buses and medium lorries of van chassis configuration: the maximum height of the vehicle shall be measured in accordance with the technical requirements of Regulation (EU) 2021/535, by not taking into account the devices and equipment referred to in Appendix 1. ▼B (viii) Adjustment the height of the semi-trailer to the target value and redo determination of maximum vehicle height if necessary. (ix) Mirrors or optical systems, roof fairing or other aerodynamic devices shall be in their regular driving condition. 3.5.3.2. Warm-up phase Drive the vehicle minimum 90 minutes at the target speed of the high speed test to warm-up the system. A repeated warm up (e.g. after a configuration change, an invalid test etc.) shall be at least as long as the standstill time. The warm-up phase can be used to perform the misalignment calibration test as specified in 3.6 of this Annex. ▼M1 In case it is not possible to maintain high speed for a complete round, e.g. due to curves being too narrow, it is allowed to deviate from target speed requirement during the curves, including the nearby straight portions that are needed for slowing down and accelerating the vehicle. Deviations shall be minimized as far as possible. Alternatively, the warm-up phase may be performed on a nearby road, if the target speed is maintained within ± 10 km/h for 90 % of the warm-up time. The part of the warm-up phase used for driving from the road to the standstill area of the test track for zeroing of the torque meters shall be included in the other warm-up phase set out in point 3.5.3.4. The time for this part shall not exceed 20 minutes. The speed and time during the warm-up phase shall be recorded by the measurement equipment. ▼B 3.5.3.3. Zeroing of torque meters The zeroing of the torque meters shall be performed as follows: i. Bring the vehicle to a standstill ii. Lift the instrumented wheels off the ground iii. Perform the zeroing of the amplifier reading of the torque meters ▼M3 The standstill phase shall not exceed 15 minutes. ▼M1 3.5.3.4. Drive another warm-up phase of minimum 10 minutes plus, if applicable, the driving from the road to the standstill area of the test track for zeroing of the torque meters at the target speed of the high speed test. ►M3 The warm-up phase in accordance with this point shall not be shorter than the standstill phase and not exceed 30 minutes. ◄ ▼M4 Any usage of the mechanical service brake during the parts of the test set out in this point and in point 3.5.3.5 invalidates the whole test. If specific vehicle settings are required to ensure that no activation of the service brake occurs during these parts, the manufacturer shall provide, upon request, the approval authority, the Commission, a market surveillance authority or a third party complying with the requirements of Regulation (EU) 2022/163 with the details of these settings to ensure that the test may be reproduced independently from the manufacturer. ▼B 3.5.3.5. First low speed testPerform the first measurement at low speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.1 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. driving at the parts of the test track outside the measurement sections and the preceding stabilisation sections shall be performed without any delay. Any unnecessary manoeuvres shall be avoided during these phases (e.g. driving in sinuous lines) ▼M4 vii. the maximum time for the low speed test shall not exceed 25 minutes in order to prevent cool down of the tyres ▼M4 ————— ▼B 3.5.3.6. Drive another warm-up phase of minimum 5 minutes at the target speed of the high speed test. 3.5.3.7. High speed testPerform the measurement at the high speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.2 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. in the driving phases outside the measurement sections and the preceding stabilization sections any unnecessary manoeuvres shall be avoided (e.g. driving in sinuous lines, unnecessary accelerations or decelerations) vii. the distance between the measured vehicle to another driven vehicle on the test track shall be at least 500 m. viii. at least 10 valid passings per heading are recorded The high speed test can be used to determine the misalignment of the anemometer if the provisions stated in 3.6 are fulfilled. ▼M4 3.5.3.8. Second low speed testPerform the second measurement at the low speed directly after the high speed test. The same provisions as for the first low speed test shall be fulfilled. ▼B 3.5.3.9. Drift check of torque metersDirectly after the finalisation of the second low speed test the drift check of the torque meters shall be performed in accordance to the following procedure: 1. Bring the vehicle to standstill 2. Lift the instrumented wheels off the ground 3. The drift of each torque meter calculated from the average of the minimum sequence of 10 seconds shall be less than 25 Nm. Exceeding this limit leads to an invalid test. 3.5.3.4. | Drive another warm-up phase of minimum 10 minutes plus, if applicable, the driving from the road to the standstill area of the test track for zeroing of the torque meters at the target speed of the high speed test. ►M3 The warm-up phase in accordance with this point shall not be shorter than the standstill phase and not exceed 30 minutes. ◄ ▼M4 Any usage of the mechanical service brake during the parts of the test set out in this point and in point 3.5.3.5 invalidates the whole test. If specific vehicle settings are required to ensure that no activation of the service brake occurs during these parts, the manufacturer shall provide, upon request, the approval authority, the Commission, a market surveillance authority or a third party complying with the requirements of Regulation (EU) 2022/163 with the details of these settings to ensure that the test may be reproduced independently from the manufacturer. 3.5.3.5. | First low speed testPerform the first measurement at low speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.1 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. driving at the parts of the test track outside the measurement sections and the preceding stabilisation sections shall be performed without any delay. Any unnecessary manoeuvres shall be avoided during these phases (e.g. driving in sinuous lines) ▼M4 vii. the maximum time for the low speed test shall not exceed 25 minutes in order to prevent cool down of the tyres ▼M4 ————— ▼B 3.5.3.6. | Drive another warm-up phase of minimum 5 minutes at the target speed of the high speed test. 3.5.3.7. | High speed testPerform the measurement at the high speed. It shall be ensured that: i. the vehicle is driven through the measurement section along a straight line as straight as possible ii. the average driving speed is in accordance with 3.5.2 of this Annex for the measurement section and the preceding stabilisation section iii. the stability of the driving speed inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item vii. of this Annex iv. the stability of the measured torque inside the measurement sections and the stabilisation sections is in accordance with 3.10.1.1 item viii. of this Annex v. the beginning and the end of the measurement sections are clearly recognizable in the measurement data via a recorded trigger signal (opto-electronic barriers plus recorded GPS data) or via use of a DGPS system vi. in the driving phases outside the measurement sections and the preceding stabilization sections any unnecessary manoeuvres shall be avoided (e.g. driving in sinuous lines, unnecessary accelerations or decelerations) vii. the distance between the measured vehicle to another driven vehicle on the test track shall be at least 500 m. viii. at least 10 valid passings per heading are recorded The high speed test can be used to determine the misalignment of the anemometer if the provisions stated in 3.6 are fulfilled. 3.5.3.8. | Second low speed testPerform the second measurement at the low speed directly after the high speed test. The same provisions as for the first low speed test shall be fulfilled. 3.5.3.9. | Drift check of torque metersDirectly after the finalisation of the second low speed test the drift check of the torque meters shall be performed in accordance to the following procedure: 1. Bring the vehicle to standstill 2. Lift the instrumented wheels off the ground 3. The drift of each torque meter calculated from the average of the minimum sequence of 10 seconds shall be less than 25 Nm. Exceeding this limit leads to an invalid test. 3.6. | Misalignment calibration testThe misalignment of the anemometer shall be determined by a misalignment calibration test on the test track. 3.6.1. At least 5 valid passings of a 250 ± 3 m straight section driven in each direction at high vehicle speed shall be performed. 3.6.2. The validity criteria for wind conditions as specified in section 3.2.5 of this Annex and the test track criteria as specified in section 3.1 of this Annex are applicable. 3.6.3. The data recorded during the misalignment calibration test shall be used by the air drag pre-processing tool to calculate the misalignment error and perform the according correction. ►M3 The signals for wheel torques and engine, cardan or average wheel speed are not used in the evaluation. ◄ 3.6.4. The misalignment calibration test can be performed independently from the constant speed test procedure. If the misalignment calibration test is performed separately it shall be executed as follows: i. Prepare the opto-electronic barriers at the 250 m ± 3 m section, or check the proper function of the DGPS System. ii. Check the vehicle setup regarding the height and geometry in accordance with 3.5.3.1 of this Annex. Adjust the height of the semi-trailer to the requirements as specified in appendix 4 to this Annex if necessary iii. No prescriptions for warm-up are applicable iv Perform the misalignment calibration test by at least 5 valid passings as described above. 3.6.5. A new misalignment test shall be performed in the following cases: a. the anemometer has been dismounted from the vehicle b. the anemometer has been moved ▼M3 c. a different tractor or rigid lorry is used ▼M1 d. the air drag family has been changed ▼B 3.6.1. | At least 5 valid passings of a 250 ± 3 m straight section driven in each direction at high vehicle speed shall be performed. 3.6.2. | The validity criteria for wind conditions as specified in section 3.2.5 of this Annex and the test track criteria as specified in section 3.1 of this Annex are applicable. 3.6.3. | The data recorded during the misalignment calibration test shall be used by the air drag pre-processing tool to calculate the misalignment error and perform the according correction. ►M3 The signals for wheel torques and engine, cardan or average wheel speed are not used in the evaluation. ◄ 3.6.4. | The misalignment calibration test can be performed independently from the constant speed test procedure. If the misalignment calibration test is performed separately it shall be executed as follows: i. Prepare the opto-electronic barriers at the 250 m ± 3 m section, or check the proper function of the DGPS System. ii. Check the vehicle setup regarding the height and geometry in accordance with 3.5.3.1 of this Annex. Adjust the height of the semi-trailer to the requirements as specified in appendix 4 to this Annex if necessary iii. No prescriptions for warm-up are applicable iv Perform the misalignment calibration test by at least 5 valid passings as described above. 3.6.5. | A new misalignment test shall be performed in the following cases: a. the anemometer has been dismounted from the vehicle b. the anemometer has been moved ▼M3 c. a different tractor or rigid lorry is used ▼M1 d. the air drag family has been changed ▼B 3.7. | Testing TemplateIn addition to the recording of the modal measurement data, the testing shall be documented in a template which contains at least the following data: i. General vehicle description (specifications see Appendix 2 - Information Document) ii. Actual maximum vehicle height as determined according to 3.5.3.1 item vii. iii. Start time and date of the test iv. Vehicle mass within a range of ± 500 kg v. Tyre pressures vi. Filenames of measurement data vii. Documentation of extraordinary events (with time and number of measurement sections), e.g. — close passing of another vehicle — manoeuvres to avoid accidents, driving errors — technical errors — measurement errors 3.8. | Data processing 3.8.1. The recorded data shall be synchronised and aligned to 100 Hz temporal resolution, either by arithmetical average, nearest neighbour or linear interpolation. 3.8.2. All recorded data shall be checked for any errors. Measurement data shall be excluded from further consideration in the following cases: — Datasets became invalid due to events during the measurement (see 3.7 item vii) — Instrument saturation during the measurement sections (e.g. high wind gusts which might have led to anemometer signal saturation) — Measurements in which the permitted limits for the torque meter drift were exceeded 3.8.3. For the evaluation of the constant speed tests the application of the latest available version of the air drag pre-processing tool shall be obligatory. Besides the above mentioned data processing, all evaluation steps including validity checks (with exception of the list as specified above) are performed by the air drag pre-processing tool. 3.8.1. | The recorded data shall be synchronised and aligned to 100 Hz temporal resolution, either by arithmetical average, nearest neighbour or linear interpolation. 3.8.2. | All recorded data shall be checked for any errors. Measurement data shall be excluded from further consideration in the following cases: — Datasets became invalid due to events during the measurement (see 3.7 item vii) — Instrument saturation during the measurement sections (e.g. high wind gusts which might have led to anemometer signal saturation) — Measurements in which the permitted limits for the torque meter drift were exceeded 3.8.3. | For the evaluation of the constant speed tests the application of the latest available version of the air drag pre-processing tool shall be obligatory. Besides the above mentioned data processing, all evaluation steps including validity checks (with exception of the list as specified above) are performed by the air drag pre-processing tool. 3.9. | ►M1 Input data for air drag pre-processing tool ◄ The following tables show the requirements for the measurement data recording and the preparatory data processing for the input into the air drag pre-processing tool: Table 2 for the vehicle data file Table 3 for the ambient conditions file Table 4 for the measurement section configuration file Table 5 for the measurement data file Table 6 for the altitude profile files (optional input data) ►M1 A detailed description of the requested data formats, the input files and the evaluation principles can be found in the technical documentation of the air drag pre-processing tool. ◄ The data processing shall be applied as specified in section 3.8 of this Annex. ▼M3 Table 1 Input data for the air drag pre-processing tool – vehicle data file Input data Unit Remarks Vehicle group code [-] 1 – 19 for heavy lorries in accordance with Table 1 of Annex I 31a – 40f for heavy buses in accordance with Tables 4 to 6 of Annex I 51 – 56 for medium lorries in accordance with Table 2 of Annex I Vehicle configuration with trailer [-] if the vehicle was measured without trailer (input ‘No’) or with trailer i.e. as a tractor semitrailer combination (input ‘Yes’) Vehicle test mass [kg] actual mass during measurements Technically permissible maximum laden mass [kg] heavy lorries: technically permissible maximum laden mass of the rigid lorry or tractor (w/o trailer or semitrailer) all other vehicle classes: no entry Axle ratio [-] axle transmission ratio (1) (2) Gear ratio high speed [-] transmission ratio of gear engaged during high speed test (1) (4) Gear ratio low speed [-] transmission ratio of gear engaged during low speed test (1) (4) Anemometer height [m] height above ground of the measurement point of installed anemometer Vehicle height [m] Medium and heavy rigid lorries and tractors: maximum vehicle height in accordance with 3.5.3.1 item vii. all other vehicle classes: no entry Fixed transmission ratio in low speed test [-] ‘yes’ / ‘no’ (for vehicles which cannot drive with locked torque converter in the low speed test) Vehicle maximum speed [km/h] maximum speed the vehicle can be practically operated at the test track () Torque meter drift left wheel [Nm] Average torque meter readings in accordance with point 3.5.3.9. Torque meter drift right wheel [Nm] Time stamp zeroing of torque meters [s] since day start (of first day) Time stamp drift check torque meters (1) specification of transmission ratios with at least 3 digits after decimal separator (2) if either the cardan speed signal or the average wheel speed signal is provided to the air drag pre-processing tool (see point 3.4.3; option 1 for vehicles with torque converters or option 2) the input parameter on axle ratio shall be set to ‘1 000 ’ (3) input only required if value is lower than 88 km/h (4) if the average wheel speed is provided to the air drag pre-processing tool (see point 3.4.3 option 2) the input parameters on gear ratios shall be set to ‘1 000 ’ ▼B Table 3 Input data for the air drag pre-processing tool – ambient conditions file Signal Column identifier in input file Unit Measurement rate Remarks Time <t> [s] since day start (first day) — — Ambient temperature <t_amb_stat> [°C] At least 1 averaged value per 6 minutes Stationary weather station Ambient pressure <p_amb_stat> [mbar] Stationary weather station Relative air humidity <rh_stat> [%] Stationary weather station ▼M1 Table 4 Input data for air drag pre-processing tool – measurement section configuration file ▼B Input data Unit Remarks Trigger signal used [-] 1 = trigger signal used; 0 = no trigger signal used Measurement section ID [-] user defined ID number Driving direction ID [-] user defined ID number Heading [°] heading of the measurement section Length of the measurement section [m] — Latitude start point of section decimal degrees or decimal minutes standard GPS, unit decimal degrees: minimum 5 digits after decimal separator Longitude start point of section standard GPS, unit decimal minutes: minimum 3 digits after decimal separator Latitude end point of section DGPS, unit decimal degrees: minimum 7 digits after decimal separator Longitude end point of section DGPS, unit decimal minutes: minimum 5 digits after decimal separator Path and/or filename of altitude file [-] only required for the constant speed tests (not the misalignment test) and if the altitude correction is enabled. Table 5 Input data for the air drag pre-processing tool – measurement data file Signal Column identifier in input file Unit Measurement rate Remarks Time <t> [s] since day start (of first day) 100 Hz rate fixed to 100 Hz; time signal used for correlation with weather data and for check of frequency (D)GPS latitude <lat> decimal degrees or decimal minutes GPS: ≥ 4 Hz DGPS: ≥ 100 Hz standard GPS, unit decimal degrees: minimum 5 digits after decimal separator (D)GPS longitude <long> standard GPS, unit decimal minutes: minimum 3 digits after decimal separator DGPS, unit decimal degrees: minimum 7 digits after decimal separator DGPS, unit decimal minutes: minimum 5 digits after decimal separator (D)GPS heading <hdg> [°] ≥ 4Hz DGPS velocity <v_veh_GPS> [km/h] ≥ 20 Hz Vehicle velocity <v_veh_CAN> [km/h] ≥ 20 Hz raw CAN bus front axle signal Air speed <v_air> [m/s] ≥ 4 Hz raw data (instrument reading) Inflow angle (beta) <beta> [°] ≥ 4 Hz raw data (instrument reading); ‘180°’ refers to air flow from front ▼M3 Engine speed, cardan speed, average wheel speed or electric motor speed <n_eng>,<n_card>, <n_wheel_ave> or <n_EM> [rpm] ≥ 20 Hz See provisions in point 3.4.3 ▼B Torque meter (left wheel) <tq_l> [Nm] ≥ 20 Hz — Torque meter (right wheel) <tq_r> [Nm] ≥ 20 Hz Ambient temperature on vehicle <t_amb_veh> [°C] ≥ 1 Hz Trigger signal <trigger> [-] 100 Hz optional signal; required if measurement sections are identified by opto electronic barriers (option ‘trigger_used=1’) Proving ground temperature <t_ground> [°C] ≥ 1 Hz Validity <valid> [-] — optional signal (1=valid; 0=invalid); ▼M4 Service brake <s_brake> [-] ≥ 4 Hz ‘Service brake demand pressure’ in accordance with ISO 11992-2:2014 (0=passive, 1=active) ▼B Table 6 Input data for the air drag pre-processing tool – altitude profile file Input data Unit Remarks Latitude decimal degrees or decimal minutes unit decimal degrees: minimum 7 digits after decimal separator Longitude unit decimal minutes: minimum 5 digits after decimal separator Altitude [m] minimum 2 digits after decimal separator Input data | Unit | Remarks Vehicle group code | [-] | 1 – 19 for heavy lorries in accordance with Table 1 of Annex I 31a – 40f for heavy buses in accordance with Tables 4 to 6 of Annex I 51 – 56 for medium lorries in accordance with Table 2 of Annex I Vehicle configuration with trailer | [-] | if the vehicle was measured without trailer (input ‘No’) or with trailer i.e. as a tractor semitrailer combination (input ‘Yes’) Vehicle test mass | [kg] | actual mass during measurements Technically permissible maximum laden mass | [kg] | heavy lorries: technically permissible maximum laden mass of the rigid lorry or tractor (w/o trailer or semitrailer) all other vehicle classes: no entry Axle ratio | [-] | axle transmission ratio (1) (2) Gear ratio high speed | [-] | transmission ratio of gear engaged during high speed test (1) (4) Gear ratio low speed | [-] | transmission ratio of gear engaged during low speed test (1) (4) Anemometer height | [m] | height above ground of the measurement point of installed anemometer Vehicle height | [m] | Medium and heavy rigid lorries and tractors: maximum vehicle height in accordance with 3.5.3.1 item vii. all other vehicle classes: no entry Fixed transmission ratio in low speed test | [-] | ‘yes’ / ‘no’ (for vehicles which cannot drive with locked torque converter in the low speed test) Vehicle maximum speed | [km/h] | maximum speed the vehicle can be practically operated at the test track () Torque meter drift left wheel | [Nm] | Average torque meter readings in accordance with point 3.5.3.9. Torque meter drift right wheel | [Nm] Time stamp zeroing of torque meters | [s] since day start (of first day) Time stamp drift check torque meters (1) specification of transmission ratios with at least 3 digits after decimal separator (2) if either the cardan speed signal or the average wheel speed signal is provided to the air drag pre-processing tool (see point 3.4.3; option 1 for vehicles with torque converters or option 2) the input parameter on axle ratio shall be set to ‘1 000 ’ (3) input only required if value is lower than 88 km/h (4) if the average wheel speed is provided to the air drag pre-processing tool (see point 3.4.3 option 2) the input parameters on gear ratios shall be set to ‘1 000 ’ Signal | Column identifier in input file | Unit | Measurement rate | Remarks Time | <t> | [s] since day start (first day) | — | — Ambient temperature | <t_amb_stat> | [°C] | At least 1 averaged value per 6 minutes | Stationary weather station Ambient pressure | <p_amb_stat> | [mbar] | Stationary weather station Relative air humidity | <rh_stat> | [%] | Stationary weather station Input data | Unit | Remarks Trigger signal used | [-] | 1 = trigger signal used; 0 = no trigger signal used Measurement section ID | [-] | user defined ID number Driving direction ID | [-] | user defined ID number Heading | [°] | heading of the measurement section Length of the measurement section | [m] | — Latitude start point of section | decimal degrees or decimal minutes | standard GPS, unit decimal degrees: minimum 5 digits after decimal separator Longitude start point of section | standard GPS, unit decimal minutes: minimum 3 digits after decimal separator Latitude end point of section | DGPS, unit decimal degrees: minimum 7 digits after decimal separator Longitude end point of section | DGPS, unit decimal minutes: minimum 5 digits after decimal separator Path and/or filename of altitude file | [-] | only required for the constant speed tests (not the misalignment test) and if the altitude correction is enabled. Signal | Column identifier in input file | Unit | Measurement rate | Remarks Time | <t> | [s] since day start (of first day) | 100 Hz | rate fixed to 100 Hz; time signal used for correlation with weather data and for check of frequency (D)GPS latitude | <lat> | decimal degrees or decimal minutes | GPS: ≥ 4 Hz DGPS: ≥ 100 Hz | standard GPS, unit decimal degrees: minimum 5 digits after decimal separator (D)GPS longitude | <long> | standard GPS, unit decimal minutes: minimum 3 digits after decimal separator DGPS, unit decimal degrees: minimum 7 digits after decimal separator DGPS, unit decimal minutes: minimum 5 digits after decimal separator (D)GPS heading | <hdg> | [°] | ≥ 4Hz DGPS velocity | <v_veh_GPS> | [km/h] | ≥ 20 Hz Vehicle velocity | <v_veh_CAN> | [km/h] | ≥ 20 Hz | raw CAN bus front axle signal Air speed | <v_air> | [m/s] | ≥ 4 Hz | raw data (instrument reading) Inflow angle (beta) | <beta> | [°] | ≥ 4 Hz | raw data (instrument reading); ‘180°’ refers to air flow from front ▼M3 Engine speed, cardan speed, average wheel speed or electric motor speed | <n_eng>,<n_card>, <n_wheel_ave> or <n_EM> | [rpm] | ≥ 20 Hz | See provisions in point 3.4.3 ▼B Torque meter (left wheel) | <tq_l> | [Nm] | ≥ 20 Hz | — Torque meter (right wheel) | <tq_r> | [Nm] | ≥ 20 Hz Ambient temperature on vehicle | <t_amb_veh> | [°C] | ≥ 1 Hz Trigger signal | <trigger> | [-] | 100 Hz | optional signal; required if measurement sections are identified by opto electronic barriers (option ‘trigger_used=1’) Proving ground temperature | <t_ground> | [°C] | ≥ 1 Hz Validity | <valid> | [-] | — | optional signal (1=valid; 0=invalid); ▼M4 Service brake | <s_brake> | [-] | ≥ 4 Hz | ‘Service brake demand pressure’ in accordance with ISO 11992-2:2014 (0=passive, 1=active) ▼B Input data | Unit | Remarks Latitude | decimal degrees or decimal minutes | unit decimal degrees: minimum 7 digits after decimal separator Longitude | unit decimal minutes: minimum 5 digits after decimal separator Altitude | [m] | minimum 2 digits after decimal separator 3.10. | Validity criteriaThis sections sets out the criteria to obtain valid results in the air drag pre-processing tool. 3.10.1. Validity criteria for the constant speed test 3.10.1.1. The air drag pre-processing tool accepts datasets as recorded during the constant speed test in case the following validity criteria are met: i. the average vehicle speed is inside the criteria as defined in 3.5.2 ii. the ambient temperature is inside the range as described in 3.2.2. This criterion is checked by the air drag pre-processing tool based on the ambient temperature measured on the vehicle. iii. the proving ground temperature is in the range as described in 3.2.3 iv. valid average wind speed conditions according to point 3.2.5 item i v. valid gust wind speed conditions according to point 3.2.5 item ii vi. valid average yaw angle conditions according to point 3.2.5 item iii vii. stability criteria for vehicle speed met: Low speed test: where: vlms,avrg = average of vehicle speed per measurement section [km/h] vlm,avrg = central moving average of vehicle speed with Xms seconds time base [km/h] Xms = time needed to drive 25 m distance at actual vehicle speed [s] High speed test: where: vhms,avrg = average of vehicle speed per measurement section [km/h] vhm,avrg = 1 s central moving average of vehicle speed [km/h] viii. stability criteria for vehicle torque met: ▼M3 Low speed test: (T lms,avrg – T grd ) × (1 – tol) ≤ (T lms,avrg – T grd ) ≤ (T lms,avrg – T grd ) × (1 + tol) T grd = F grd,avrg × r dyn,avrg where: Tlms,avrg = average of Tsum per measurement section Tgrd = average torque from gradient force Fgrd,avrg = average gradient force over measurement section rdyn,avrg = average effective rolling radius over measurement section (formula see item xi) [m] Tsum = TL + TR ; sum of corrected torque values left and right wheel [Nm] T lm,avrg = central moving average of Tsum with Xms seconds time base Xms = time needed to drive 25 m distance at actual vehicle speed [s] tol = relative torque tolerance: 0.5 for medium lorries and heavy lorries in groups 1s, 1 and 2; 0.3 for heavy lorries in other groups and heavy buses ▼B High speed test where: Thms,avrg = average of Tsum per measurement section [Nm] Tgrd = average torque from gradient force (see Low speed test) [Nm] Tsum = TL+TR ; sum of corrected torque values left and right wheel [Nm] Thm,avrg = 1 s central moving average of Tsum [Nm] ix. valid heading of the vehicle passing a measurement section (< 10° deviation from target heading applicable for low speed test, high speed test and misalignment test) x. driven distance inside measurement section calculated from the calibrated vehicle speed does not differ from target distance by more than 3 meters (applicable for low speed test and high speed test) ▼M1 xi. ►M3 plausibility check for engine speed, cardan speed or average wheel speed, whichever is applicable passed: ◄ ►M3 engine speed or average wheel speed ◄ check for high speed test: where: igear = transmission ratio of the gear selected in high speed test [-] iaxle = axle transmission ratio [-] vhms,avrg = average vehicle speed (high speed measurement section) [km/h] neng,1s = 1 s central moving average of ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] neng,avrg = average ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] rdyn,avrg = average effective rolling radius for a single high speed measurement section [m] rdyn,ref,HS = reference effective rolling radius calculated from all valid high speed measurement sections (number = n) [m] ►M3 engine speed or average wheel speed ◄ check for low speed test: where: igear = transmission ratio of the gear selected in low speed test [-] iaxle = axle transmission ratio [-] vlms,avrg = average vehicle speed (low speed measurement section) [km/h] neng,float = central moving average of ►M3 engine speed or average wheel speed ◄ with Xms seconds time base (low speed measurement section) [rpm] neng,avrg = average ►M3 engine speed or average wheel speed ◄ (low speed measurement section) [rpm] Xms = time needed to drive 25 metre distance at low speed [s] rdyn,avrg = average effective rolling radius for a single low speed measurement section [m] rdyn,ref,LS1/LS2 = reference effective rolling radius calculated from all valid measurement sections for low speed test 1 or low speed test 2 (number = n) [m] The plausibility check for cardan speed is performed in an analogue way with neng,1s replaced by ncard,1s (1 s central moving average of cardan speed in the high speed measurement section) and neng,float replaced by ncard,float (moving average of cardan speed with Xms seconds time base in the low speed measurement section) and igear set to a value of 1. ▼B xii. the particular part of the measurement data was not marked as ‘invalid’ in the air drag pre-processing tool input file. 3.10.1.2. The air drag pre-processing tool excludes single datasets from the evaluation in the case of unequal number of datasets for a particular combination of measurement section and driving direction for the first and the second low speed test. In this case the first datasets from the low speed run with the higher number of datasets are excluded. 3.10.1.3. The air drag pre-processing tool excludes single combinations of measurement sections and driving directions from the evaluation if: i. no valid dataset is available from low speed test 1 or/and low speed test 2 ii. less than two valid datasets from the high speed test are available 3.10.1.4. The air drag pre-processing tool considers the complete constant speed test invalid in the following cases: i. test track requirements as described in 3.1.1 not met ii. less than 10 datasets per heading available (high speed test) iii. less than 5 valid datasets per heading available (misalignment calibration test) iv. the rolling resistance coefficients (RRC) for the first and the second low speed test differ more than 0,40 kg/t. This criterion is checked for each combination of measurement section and driving direction separately. 3.10.2. Validity criteria for the misalignment test 3.10.2.1. The air drag pre-processing tool accepts datasets as recorded during the misalignment test in case the following validity criteria are met: i. the average vehicle speed is inside the criteria as defined in 3.5.2 for the high speed test ii. valid average wind speed conditions according to point 3.2.5 item i iii. valid gust wind speed conditions according to point 3.2.5 item ii iv. valid average yaw angle conditions according to point 3.2.5 item iii v. stability criteria for vehicle speed met: where: vhms,avrg = average of vehicle speed per measurement section [km/h] vhm,avrg = 1 s central moving average of vehicle speed [km/h] 3.10.2.2. The air drag pre-processing tool considers the data from a single measurement section invalid in the following cases: i. the average vehicle speeds from all valid datasets from each driving directions differ by more than 2 km/h. ii. less than 5 datasets per heading available 3.10.2.3. The air drag pre-processing tool considers the complete misalignment test invalid in case no valid result for a single measurement section is available. 3.10.1.1. | The air drag pre-processing tool accepts datasets as recorded during the constant speed test in case the following validity criteria are met: i. the average vehicle speed is inside the criteria as defined in 3.5.2 ii. the ambient temperature is inside the range as described in 3.2.2. This criterion is checked by the air drag pre-processing tool based on the ambient temperature measured on the vehicle. iii. the proving ground temperature is in the range as described in 3.2.3 iv. valid average wind speed conditions according to point 3.2.5 item i v. valid gust wind speed conditions according to point 3.2.5 item ii vi. valid average yaw angle conditions according to point 3.2.5 item iii vii. stability criteria for vehicle speed met: Low speed test: where: vlms,avrg = average of vehicle speed per measurement section [km/h] vlm,avrg = central moving average of vehicle speed with Xms seconds time base [km/h] Xms = time needed to drive 25 m distance at actual vehicle speed [s] High speed test: where: vhms,avrg = average of vehicle speed per measurement section [km/h] vhm,avrg = 1 s central moving average of vehicle speed [km/h] viii. stability criteria for vehicle torque met: ▼M3 Low speed test: (T lms,avrg – T grd ) × (1 – tol) ≤ (T lms,avrg – T grd ) ≤ (T lms,avrg – T grd ) × (1 + tol) T grd = F grd,avrg × r dyn,avrg where: Tlms,avrg = average of Tsum per measurement section Tgrd = average torque from gradient force Fgrd,avrg = average gradient force over measurement section rdyn,avrg = average effective rolling radius over measurement section (formula see item xi) [m] Tsum = TL + TR ; sum of corrected torque values left and right wheel [Nm] T lm,avrg = central moving average of Tsum with Xms seconds time base Xms = time needed to drive 25 m distance at actual vehicle speed [s] tol = relative torque tolerance: 0.5 for medium lorries and heavy lorries in groups 1s, 1 and 2; 0.3 for heavy lorries in other groups and heavy buses ▼B High speed test where: Thms,avrg = average of Tsum per measurement section [Nm] Tgrd = average torque from gradient force (see Low speed test) [Nm] Tsum = TL+TR ; sum of corrected torque values left and right wheel [Nm] Thm,avrg = 1 s central moving average of Tsum [Nm] ix. valid heading of the vehicle passing a measurement section (< 10° deviation from target heading applicable for low speed test, high speed test and misalignment test) x. driven distance inside measurement section calculated from the calibrated vehicle speed does not differ from target distance by more than 3 meters (applicable for low speed test and high speed test) ▼M1 xi. ►M3 plausibility check for engine speed, cardan speed or average wheel speed, whichever is applicable passed: ◄ ►M3 engine speed or average wheel speed ◄ check for high speed test: where: igear = transmission ratio of the gear selected in high speed test [-] iaxle = axle transmission ratio [-] vhms,avrg = average vehicle speed (high speed measurement section) [km/h] neng,1s = 1 s central moving average of ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] neng,avrg = average ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] rdyn,avrg = average effective rolling radius for a single high speed measurement section [m] rdyn,ref,HS = reference effective rolling radius calculated from all valid high speed measurement sections (number = n) [m] ►M3 engine speed or average wheel speed ◄ check for low speed test: where: igear = transmission ratio of the gear selected in low speed test [-] iaxle = axle transmission ratio [-] vlms,avrg = average vehicle speed (low speed measurement section) [km/h] neng,float = central moving average of ►M3 engine speed or average wheel speed ◄ with Xms seconds time base (low speed measurement section) [rpm] neng,avrg = average ►M3 engine speed or average wheel speed ◄ (low speed measurement section) [rpm] Xms = time needed to drive 25 metre distance at low speed [s] rdyn,avrg = average effective rolling radius for a single low speed measurement section [m] rdyn,ref,LS1/LS2 = reference effective rolling radius calculated from all valid measurement sections for low speed test 1 or low speed test 2 (number = n) [m] The plausibility check for cardan speed is performed in an analogue way with neng,1s replaced by ncard,1s (1 s central moving average of cardan speed in the high speed measurement section) and neng,float replaced by ncard,float (moving average of cardan speed with Xms seconds time base in the low speed measurement section) and igear set to a value of 1. ▼B xii. the particular part of the measurement data was not marked as ‘invalid’ in the air drag pre-processing tool input file. vlms,avrg | = | average of vehicle speed per measurement section [km/h] vlm,avrg | = | central moving average of vehicle speed with Xms seconds time base [km/h] Xms | = | time needed to drive 25 m distance at actual vehicle speed [s] vhms,avrg | = | average of vehicle speed per measurement section [km/h] vhm,avrg | = | 1 s central moving average of vehicle speed [km/h] Tlms,avrg | = | average of Tsum per measurement section Tgrd | = | average torque from gradient force Fgrd,avrg | = | average gradient force over measurement section rdyn,avrg | = | average effective rolling radius over measurement section (formula see item xi) [m] Tsum | = | TL + TR ; sum of corrected torque values left and right wheel [Nm] T lm,avrg | = | central moving average of Tsum with Xms seconds time base Xms | = | time needed to drive 25 m distance at actual vehicle speed [s] tol | = | relative torque tolerance: 0.5 for medium lorries and heavy lorries in groups 1s, 1 and 2; 0.3 for heavy lorries in other groups and heavy buses Thms,avrg | = | average of Tsum per measurement section [Nm] Tgrd | = | average torque from gradient force (see Low speed test) [Nm] Tsum | = | TL+TR ; sum of corrected torque values left and right wheel [Nm] Thm,avrg | = | 1 s central moving average of Tsum [Nm] igear | = | transmission ratio of the gear selected in high speed test [-] iaxle | = | axle transmission ratio [-] vhms,avrg | = | average vehicle speed (high speed measurement section) [km/h] neng,1s | = | 1 s central moving average of ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] neng,avrg | = | average ►M3 engine speed or average wheel speed ◄ (high speed measurement section) [rpm] rdyn,avrg | = | average effective rolling radius for a single high speed measurement section [m] rdyn,ref,HS | = | reference effective rolling radius calculated from all valid high speed measurement sections (number = n) [m] igear | = | transmission ratio of the gear selected in low speed test [-] iaxle | = | axle transmission ratio [-] vlms,avrg | = | average vehicle speed (low speed measurement section) [km/h] neng,float | = | central moving average of ►M3 engine speed or average wheel speed ◄ with Xms seconds time base (low speed measurement section) [rpm] neng,avrg | = | average ►M3 engine speed or average wheel speed ◄ (low speed measurement section) [rpm] Xms | = | time needed to drive 25 metre distance at low speed [s] rdyn,avrg | = | average effective rolling radius for a single low speed measurement section [m] rdyn,ref,LS1/LS2 | = | reference effective rolling radius calculated from all valid measurement sections for low speed test 1 or low speed test 2 (number = n) [m] 3.10.1.2. | The air drag pre-processing tool excludes single datasets from the evaluation in the case of unequal number of datasets for a particular combination of measurement section and driving direction for the first and the second low speed test. In this case the first datasets from the low speed run with the higher number of datasets are excluded. 3.10.1.3. | The air drag pre-processing tool excludes single combinations of measurement sections and driving directions from the evaluation if: i. no valid dataset is available from low speed test 1 or/and low speed test 2 ii. less than two valid datasets from the high speed test are available 3.10.1.4. | The air drag pre-processing tool considers the complete constant speed test invalid in the following cases: i. test track requirements as described in 3.1.1 not met ii. less than 10 datasets per heading available (high speed test) iii. less than 5 valid datasets per heading available (misalignment calibration test) iv. the rolling resistance coefficients (RRC) for the first and the second low speed test differ more than 0,40 kg/t. This criterion is checked for each combination of measurement section and driving direction separately. 3.10.2.1. | The air drag pre-processing tool accepts datasets as recorded during the misalignment test in case the following validity criteria are met: i. the average vehicle speed is inside the criteria as defined in 3.5.2 for the high speed test ii. valid average wind speed conditions according to point 3.2.5 item i iii. valid gust wind speed conditions according to point 3.2.5 item ii iv. valid average yaw angle conditions according to point 3.2.5 item iii v. stability criteria for vehicle speed met: where: vhms,avrg = average of vehicle speed per measurement section [km/h] vhm,avrg = 1 s central moving average of vehicle speed [km/h] vhms,avrg | = | average of vehicle speed per measurement section [km/h] vhm,avrg | = | 1 s central moving average of vehicle speed [km/h] 3.10.2.2. | The air drag pre-processing tool considers the data from a single measurement section invalid in the following cases: i. the average vehicle speeds from all valid datasets from each driving directions differ by more than 2 km/h. ii. less than 5 datasets per heading available 3.10.2.3. | The air drag pre-processing tool considers the complete misalignment test invalid in case no valid result for a single measurement section is available.
1. Introductionchanged
This Annex describes the provisions regarding the power consumption declaration of auxiliaries technologies and other relevant input information on auxiliary systems for heavy duty vehicles for the purpose of the determination of vehicle specific CO2 emissions. The power consumption of the following auxiliaries auxiliary types shall be considered within the simulation tool by using technology specific average standard generic models for power values: Fan Steering system Electric system Pneumatic system Air Conditioning (AC) system Transmission Power Take Off (PTO) The standard values are integrated in the simulation tool and automatically used by choosing the corresponding technology. consumption:
2. Definitionschanged
For the purposes of this Annex the following definitions shall apply: ‘Crankshaft mounted fan’ means a fan installation where the fan apply. The related auxiliary type is driven stated in the prolongation of the crankshaft, often by a flange; ‘Belt or transmission driven fan’ means a fan that is installed in a position where additional belt, tension system or transmission is needed; ‘Hydraulic driven fan’ means a fan propelled by hydraulic oil, often installed away from the engine. A hydraulic system with oil system, pump and valves are influencing losses and efficiencies in the system; ‘Electrically driven fan’ means a fan propelled by an electric motor. The efficiency for complete energy conversion, included in/out from battery, is considered; ‘Electronically controlled visco clutch’ means a clutch in which a number of sensor inputs together with SW logic are used to electronically actuate the fluid flow in the visco clutch; ‘Bimetallic controlled visco clutch’ means a clutch in which a bimetallic connection is used to convert a temperature change into mechanical displacement. The mechanical displacement is then working as an actuator for the visco clutch; ‘Discrete step clutch’ means a mechanical device where the grade of actuation can be made in distinct steps only (not continuous variable). ‘On/off clutch’ means a mechanical clutch which is either fully engaged or fully disengaged; ‘Variable displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump can be varied while the pump is running; ‘Constant displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump cannot be varied while the pump is running; ‘Electric motor control’ means the use of an electric motor to propel the fan. The electrical machine converts electrical energy into mechanical energy. Power and speed are controlled by conventional technology for electric motors; ‘Fixed displacement pump (default technology)’ means a pump having an internal limitation of the flow rate; ‘Fixed displacement pump with electronic control’ means a pump using an electronic control of the flow rate; ‘Dual displacement pump’ means a pump with two chambers (with the same or different displacement) which can be combined or only one of these is used. It is characterised by an internal limitation of flow rate; ‘Variable displacement pump mech. controlled’ means a pump where the displacement is mechanically controlled internally (internal pressure scales); ‘Variable displacement pump elec. controlled’ means a pump where the displacement is mechanically controlled internally (internal pressure scales). Additionally, the flow rate is elec. controlled by a valve; ‘Electric steering pump’ means a hydraulic pump driven by an electric motor; ‘Baseline air compressor’ means a conventional air compressor without any fuel saving technology; ‘Air compressor with Energy Saving System (ESS)’ means a compressor reducing the power consumption during blow off, e.g. by closing intake side, ESS is controlled by system air pressure; ‘Compressor clutch (visco)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy), minor losses during disengaged state caused by visco clutch; ‘Compressor clutch (mechanically)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy); ‘Air Management System with optimal regeneration (AMS)’ means an electronic air processing unit that combines an electronically controlled air dryer for optimized air regeneration and an air delivery preferred during overrun conditions (requires a clutch or ESS). ‘Light Emitting Diodes (LED)’ mean semiconductor devices that emit visible light when an electrical current passes through them. ‘Air conditioning system’ means a system consisting of a refrigerant circuit with compressor and heat exchangers to cool down the interior of a truck cab or bus body. ‘Power take-off (PTO)’ means a device on a transmission or an engine to which an auxiliary driven device, e.g., a hydraulic pump, can be connected; a power take-off is usually optional; ‘Power take-off drive mechanism’ means a device in a transmission that allows the installation of a power take-off (PTO); ‘Tooth clutch’ means a (manoeuvrable) clutch where torque is transferred mainly by normal forces between mating teeth. A tooth clutch can either be engaged or disengaged. It is operated in load-free conditions only (e.g. at gear shifts in a manual transmission); ‘Synchroniser’ means a type of tooth clutch where a friction device is used to equalise the speeds of the rotating parts to be engaged; ‘Multi-disc clutch’ means a clutch where several friction linings are arranged in parallel whereby all friction pairs get the same pressing force. Multi-disc clutches are compact and can be engaged and disengaged under load. They may be designed as dry or wet clutches; ‘Sliding wheel’ means a gearwheel used as shift element where the shifting is realized by moving the gearwheel on its shaft into or out of the gear mesh of the mating gear. brackets.
3.2. Steering systemchanged
For vehicles heavy lorries with PTO and/or PTO drive mechanism installed on the transmission, the power consumption shall be considered by determined standard generic values. The corresponding standard values Those represent these power losses in usual drive mode when the PTO consumer connected to a PTO, e.g. a hydraulic pump, is switched off/disengaged. ►M1 Application related power consumptions at engaged PTO consumer are added by the simulation tool and are not described in the following. ◄ Table 10 15 Mechanical power demand of PTOs with switched off/disengaged power take-off off consumers for heavy lorries Design variants regarding power losses (in comparison to a transmission without PTO and / or PTO drive mechanism) | Power loss Additional drag loss relevant parts | PTO incl. drive mechanism | only PTO drive mechanism Shafts / gear wheels (P247) | Other elements (P248) | Power loss [W] | Power loss [W] only one engaged gearwheel positioned above the specified oil level (no additional gearmesh) | — | — | 0 only the drive shaft of the PTO | tooth clutch (incl. synchroniser) or sliding gearwheel | 50 | 50 only the drive shaft of the PTO | multi-disc clutch | 1 000 | 1 000 350 only the drive shaft of the PTO | multi-disc clutch and oil with dedicated pump for PTO clutch | 2 000 | 2 3 000 drive shaft and/or up to 2 engaged gearwheels | tooth clutch (incl. synchroniser) or sliding gearwheel | 300 | 300 150 drive shaft and/or up to 2 engaged gearwheels | multi-disc clutch | 1 500 | 1 500 400 drive shaft and/or up to 2 engaged gearwheels | multi-disc clutch and oil with dedicated pump for PTO clutch | 3 000 | 3 000 050 drive shaft and/or more than 2 engaged gearwheels | tooth clutch (incl. synchroniser) or sliding gearwheel | 600 | 600 200 drive shaft and/or more than 2 engaged gearwheels | multi-disc clutch | 2 000 | 2 000 450 drive shaft and/or more than 2 engaged gearwheels | multi-disc clutch with dedicated pump for PTO clutch | 3 100 PTO which includes 1 or more additional gearmesh(es), without disconnect clutch | — | 1 500 In the case of multiple PTOs mounted to the transmission, only the component with the highest losses in accordance with Table 15, for its combination of criteria ‘PTOShaftsGearWheels’ and oil pump | 4 000 | 4 000 ‘PTOShaftsOtherElements’, shall be declared. For medium lorries and heavy buses, no declaration of transmission PTOs is foreseen.
2. Definitionschanged
For the purposes of this Annex, in addition to the definitions contained in UN/ECE UN Regulation No. 54 ( 17 ) and in UN/ECE UN Regulation No.117, No. 117 ( 18 ), the following definitions shall apply: ‘Rolling resistance coefficient Cr’ means a ratio of the rolling resistance to the load on the tyre ‘The load on the tyre FZTYRE’ means a load applied to the tyre during the rolling resistance test. ‘Type of tyre’ means a range of tyres which do not differ in such characteristics as: Manufacturer's name; Brand name or trade mark Tyre class (in accordance with Regulation (EC) No 661/2009) Tyre-size designation; Tyre structure (diagonal (bias-ply), radial); Category of use (normal tyre, snow tyre, special use tyre) as defined in UN/ECE Regulation No.117; Speed category (categories); Load-capacity index (indices); Trade description/commercial name; Declared tyre rolling resistance coefficient
3. General requirementschanged
3.1. | The tyre manufacturer plant shall be certified to ISO/TS ►M3 IATF ◄ 16949. 3.2. | Tyre rolling resistance coefficientThe coefficient measurementThe tyre rolling resistance coefficient shall be the value measured and aligned in accordance with Regulation (EC) No 1222/2009, (EU) 2020/740 Annex I I, part A, expressed in N/kN and rounded to the first decimal place, according to in accordance with ISO 80000-1 Appendix B, section B.3, rule B (example 1). The standard rolling resistance coefficient value for C2 and C3 tyres shall be the one corresponding to snow tyres for use in severe snow conditions as set out in UN Regulation No. 117 paragraph 6.3.2. For tyres not in the scope of Regulation (EC) No 661/2009 ( 20 ) or Regulation (EU) 2019/2144 ( 21 ), the standard value shall be 13,0 N/kN and the FuelEfficiencyClass shall be stated as ‘N/A’. The standard FzISO value shall be the one obtained as a percentage of the vertical force related to tyre load index at nominal tyre pressure (and single tyre application). For C2 and C3 tyres this percentage shall be 85 %, for other tyres the percentage shall be 80 %. 3.3. | Measurement provisionsThe tyre manufacturer shall test either in a laboratory of Technical Services technical services as defined in Article 41 68 of Directive 2007/46/EC which carry out in its own facility Regulation (EU) 2018/858 the test referred to in paragraph point 3.2, or in its own facilities in the case: case that: (i) of the presence and responsibility of a representative of a Technical Service technical service designated by an the responsible approval authority, authority supervises the test; or (ii) the tyre manufacturer is designated as a technical service of Category A in accordance with Directive 2007/46/EC Art.41. Article 68 of Regulation (EU) 2018/858. 3.4. | Marking and traceability ▼M1 ▼M3 3.4.1. The tyre shall be clearly identifiable in respect to the applicable certificate covering it for and the corresponding rolling resistance coefficient. ▼B 3.4.2. ►M1 The tyre manufacturer shall use the markings affixed to the side wall of the tyre or affix an additional identifier to the tyre. ◄ The additional identification shall ensure a unique link of the tyre and its rolling resistance coefficient. It may take a form of: — quick response (QR) code, — barcode, — radio-frequency identification (RFID), — an additional marking, or — other tool fulfilling the requirements of 3.4.1. 3.4.3. If an additional identifier is used it shall remain readable until the moment of sales of the vehicle. 3.4.4. ►M3 In line with Article 19(2) 38(2) of Directive 2007/46/EC, Regulation (EU) 2018/858, no type-approval mark is required for tyre tyres certified in accordance with this Regulation. ◄ 3.4.1. | The tyre shall be clearly identifiable in respect to the applicable certificate covering it for and the corresponding rolling resistance coefficient. 3.4.2. | ►M1 The tyre manufacturer shall use the markings affixed to the side wall of the tyre or affix an additional identifier to the tyre. ◄ The additional identification shall ensure a unique link of the tyre and its rolling resistance coefficient. It may take a form of: — quick response (QR) code, — barcode, — radio-frequency identification (RFID), — an additional marking, or — other tool fulfilling the requirements of 3.4.1. 3.4.3. | If an additional identifier is used it shall remain readable until the moment of sales of the vehicle. 3.4.4. | ►M3 In line with Article 19(2) 38(2) of Directive 2007/46/EC, Regulation (EU) 2018/858, no type-approval mark is required for tyre tyres certified in accordance with this Regulation. ◄
4.1. | Any tyre certified under this Regulation shall be in conformity to the declared rolling resistance value as per paragraph 3.2 of this Annex. 4.2. | In order to verify conformity of the certified CO2 emissions and fuel consumption related properties, production samples shall be taken randomly from series production and tested in accordance with the provisions set out in paragraph 3.2. ►M3 The tests have to be performed on new test tyres in the sense of the definition set out in paragraph 2 of UN Regulation No. 117. ◄ 4.3. | Frequency of the tests 4.3.1 The tyre rolling resistance of at least one tyre of a specific type intended for the sales to the original equipment manufacturers shall be tested every 20 000 units of this type per year (e.g. 2 conformity verifications per year of the type whose annual sales volume to the original equipment manufacturers is between 20 001 and 40 000 units). 4.3.2 In case the deliveries of a specific tyre type intended for the sales to the original equipment manufacturers is between 500 and 20 000 units per year, at least one conformity verification of the type shall be carried out per year. 4.3.3 In case the deliveries of a specific tyre type intended for the sales to the original equipment manufacturers is below 500 units, at least one conformity verification as described in paragraph 4.4 shall be applied every second year. 4.3.4 If the volume of tyres delivered to the original equipment manufacturers indicated in 4.3.1 is met within 31 calendar days the maximum number of conformity verifications as described in paragraph 4.3 is limited to one per 31 calendar days. 4.3.5 The manufacturer shall justify (ex. by showing sales numbers) to the approval authority the number of tests which has been performed 4.3.1 | The tyre rolling resistance of at least one tyre of a specific type intended for the sales to the original equipment manufacturers shall be tested every 20 000 units of this type per year (e.g. 2 conformity verifications per year of the type whose annual sales volume to the original equipment manufacturers is between 20 001 and 40 000 units). 4.3.2 | In case the deliveries of a specific tyre type intended for the sales to the original equipment manufacturers is between 500 and 20 000 units per year, at least one conformity verification of the type shall be carried out per year. 4.3.3 | In case the deliveries of a specific tyre type intended for the sales to the original equipment manufacturers is below 500 units, at least one conformity verification as described in paragraph 4.4 shall be applied every second year. 4.3.4 | If the volume of tyres delivered to the original equipment manufacturers indicated in 4.3.1 is met within 31 calendar days the maximum number of conformity verifications as described in paragraph 4.3 is limited to one per 31 calendar days. 4.3.5 | The manufacturer shall justify (ex. by showing sales numbers) to the approval authority the number of tests which has been performed 4.4 | Verification procedure 4.4.1 A single tyre shall be tested in accordance with paragraph 3.2. By default, the machine alignment equation shall be the one valid at the date of verification testing. Tyre manufacturer may request the application of the alignment equation that was used during the certification testing and reported in the information document. ►M3 ————— ◄ ▼M3 4.4.2 In the case that the measured and aligned value measured is lower or equal to the declared value plus 0,3 N/kN, the tyre rolling resistance value is considered compliant. 4.4.3. In 4.4.3 Where the case, measured and aligned value exceeds the declared value by more than 0,3 N/kN, the alignment equation that was valid at the time of the certification testing may be applied upon request of the tyre manufacturer and in agreement with the authority that is supervising the verification. ▼M3 4.4.3.1 If the measured and realigned value is lower or equal to the declared value plus 0,3 N/kN, the tyre rolling resistance value is considered compliant. 4.4.3.2 If the measured value, aligned as per points 4.4.3 and 4.4.3.1, exceeds the declared value by more than 0,3 N/kN, three additional tyres shall be tested. If the value of the rolling resistance measured value, aligned as per points 4.4.3 and 4.4.3.1, of at least one of the three tyres exceeds the declared value by more than 0,4 N/kN, provisions of Article 23 shall apply. 4.4.1 | A single tyre shall be tested in accordance with paragraph 3.2. By default, the machine alignment equation shall be the one valid at the date of verification testing. Tyre manufacturer may request the application of the alignment equation that was used during the certification testing and reported in the information document. ►M3 ————— ◄ 4.4.2 | In the case that the measured and aligned value measured is lower or equal to the declared value plus 0,3 N/kN, the tyre rolling resistance value is considered compliant. 4.4.3. 4.4.3 | In Where the case, measured and aligned value exceeds the declared value by more than 0,3 N/kN, the alignment equation that was valid at the time of the certification testing may be applied upon request of the tyre manufacturer and in agreement with the authority that is supervising the verification. ▼M3 4.4.3.1 If the measured and realigned value is lower or equal to the declared value plus 0,3 N/kN, the tyre rolling resistance value is considered compliant. 4.4.3.2 If the measured value, aligned as per points 4.4.3 and 4.4.3.1, exceeds the declared value by more than 0,3 N/kN, three additional tyres shall be tested. If the value of the rolling resistance measured value, aligned as per points 4.4.3 and 4.4.3.1, of at least one of the three tyres exceeds the declared value by more than 0,4 N/kN, provisions of Article 23 shall apply. 4.4.3.1 | If the measured and realigned value is lower or equal to the declared value plus 0,3 N/kN, the tyre rolling resistance value is considered compliant. 4.4.3.2 | If the measured value, aligned as per points 4.4.3 and 4.4.3.1, exceeds the declared value by more than 0,3 N/kN, three additional tyres shall be tested. If the measured value, aligned as per points 4.4.3 and 4.4.3.1, of at least one of the three tyres exceeds the declared value by more than 0,4 N/kN, Article 23 shall apply.