Compare versions of (EU) 44/2014
Supplementing Regulation (EU) No 168/2013 of the European Parliament and of the Council with regard to the vehicle construction and general requirements for the approval of two- or three-wheel vehicles and quadricycles Text with EEA relevance
UNECE regulation No | Subject | Series of amendments | OJ reference | Applicability 10 | Electromagnetic compatibility (EMC) | Supplement 1 to the 04 series of amendments | OJ L 254, 20.9.2012, p. 1. | L1e, L2e, L3e, L4e, L5e, L6e and L7e 62 | Protection against unauthorised use | Supplement 2 to the 00 series of amendments | OJ L 89, 27.3.2013, p. 37. | L1e, L2e, L3e, L4e, L5e, L6e and L7e ▼M3 155 | Cyber security and cyber security management system | Supplement 3 to the 00 series of amendments | OJ L, 2025/5, 10.1.2025, ELI: http://data.europa.eu/eli/reg/2025/5/oj | L1e, L2e, L3e, L4e, L5e, L6e and L7e, except L1e category vehicles designed to pedal referred to in Article 3, point (94)(b), of Regulation (EU) No 168/2013 ▼M1 Explanatory note: The fact that a component is included in this list does not make its installation mandatory. For certain components, however, mandatory installation requirements are laid down in other annexes to this Regulation.
8.1.deleted
Text of image
Manufacturer
Mathematical model
Validation process
Physical prototype
Physical Test
Computer Simulation
Validation report
Agreement Approval Authority
Approval process
Virtual Prototypes I, II, …
Computer Simulation
Technical Report acc. to EU Regulation
Approval Authority
4.1.1. | Test type I on emissions after cold start, type II on increased idle emissions and type VII on measurement of CO2 emissions, fuel consumption, electric energy consumption and electric range determination 4.1.1.1. Vehicles shall be manufactured in conformity with the approved vehicle type. 4.1.1.2. Appropriate conformity of production checks shall be carried out to verify compliance with the conditions referred to in point 4.1.1.1. 4.1.1.3. Vehicles powered by an internal combustion engine only: 4.1.1.3.1. As a general rule, measures to ensure the conformity of production with regard to ►M1 tailpipe pollutant and CO2 emissions ◄ from vehicles are to be checked on the basis of the description in the type-approval certificate conforming to the model set out in Article 30(2) of Regulation (EU) No 168/2013. The control of production conformity is based on an assessment by the approval authority of the manufacturer’s auditing procedure in order to ensure conformity of the manufactured vehicle with respect to the ►M1 tailpipe pollutant and CO2 emissions ◄ . If the approval authority is not satisfied with the standard of the manufacturer’s auditing procedure, it may require that verification tests be carried out on vehicles in production. 4.1.1.3.1.1. Measurements of the ►M1 tailpipe pollutant and CO2 emissions ◄ of a vehicle type that has had one or several extensions shall be carried out on the vehicle(s) available at the time of the test (vehicle(s) described in the first document or in subsequent extensions). 4.1.1.3.1.1.1. Conformity of the vehicle for type I, tailpipe emissions after cold start and type VII, CO2 emission test 4.1.1.3.1.1.1.1. Three vehicles shall be randomly selected from the series and tested according to the requirements set out in Articles 23 and 24 of Regulation (EU) No 168/2013. Deterioration factors shall be applied to the average of the test type I pollutant emission test results as follows: ▼M2 4.1.1.3.1.1.1.1.1. If the durability method set out in Article 23(3)(a) of Regulation (EU) No 168/2013 is applicable, the deterioration factors shall be calculated from the type I emission test results up to and including full distance referred to in Annex VII(A) to Regulation (EU) No 168/2013 and in accordance with the linear calculation method referred to in point 4.1.1.3.1.1.1.1.2. resulting in slope and offset values per emission constituent. The CoP pollutant emission results shall be calculated with the formula: Equation 4-1: Yfull = a (Xfull – XCoP) + YCoP where: a = slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull = durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP = Mileage of the CoP vehicle at moment of Type I CoP test; Yfull = CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP = pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.1.2. If the durability method set out in Article 23(3)(b) of Regulation (EU) No 168/2013 is applicable, the deterioration trend shall consist of the slope value a, as is reflected in point 4.1.1.3.1.1.1.1.1, per emission constituent calculated to comply with test type V in accordance with Annex V(A) to Regulation (EU) No 168/2013. Equation 4-1 shall be used to calculate the CoP emission results per pollutant emission constituent (Yfull). 4.1.1.3.1.1.1.1.3. If the durability method set out in Article 23(3)(c) of Regulation (EU) No 168/2013 is applicable, the fixed deterioration factors set out in Annex VII(B) to Regulation (EU) No 168/2013 shall be multiplied by the type test I result of the CoP vehicle (Ycop) to calculate the average CoP emission results per pollutant emission constituent (Yfull). ▼B 4.1.1.3.1.1.1.1.4. The average test type VII results (CO2 emissions, fuel/energy consumption and electric range if applicable) shall be lower than or equal to the declared values by the manufacturer at type-approval. 4.1.1.3.1.1.1.1.5. If the average emissions of the first two vehicles comply with the requirements laid down in point 4.1.1.3.1.1.1.1 then the production conformity is considered as satisfactory. 4.1.1.3.1.1.1.2. If the average emissions of the first two vehicles do not comply, the CoP procedure continues as follows: 4.1.1.3.1.1.1.2.1. If the authority is satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.2. 4.1.1.3.1.1.1.2.2. If the authority is not satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.3. 4.1.1.3.1.1.1.3. The production of a series is regarded as conforming or non-conforming, on the basis of tests on the three sampled vehicles, once a pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ according to the test criteria applied in the appropriate table. If no pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ , a test is carried out on an additional vehicle (see Figure 4-1). 4.1.1.3.1.1.1.4. In the case of periodically regenerating systems, the results shall be multiplied by the factor Ki obtained at the time when type-approval was granted. At the request of the manufacturer, testing may be carried out immediately after a regeneration has been completed. Figure 4-1 Pass/fail criteria for Type I, II and VII testing Text of image Test on three vehicles Computation of the test statistic According to the appropriate table does the test statistic agree with the criteria for failing the series ? Series Rejected According to the appropriate table does the test statistic agree with the criteria for passing the series ? Series Accepted Test of an additional vehicle 4.1.1.3.1.1.2. Notwithstanding the environmental requirements set out in Article 23 and 24 of Regulation (EU) No 168/2013, the tests will be carried out on vehicles which have travelled a maximum distance of 100 km after first start at the production line. 4.1.1.3.1.1.2.1. However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.2. Conformity of production when manufacturer’s statistical data are available 4.1.1.3.2.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s production standard deviation is again satisfactory. 4.1.1.3.2.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.2.3. The following procedure is used (see Figure 4-1): Let L be the natural logarithm of ►M1 tailpipe pollutant emission limits ◄ set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval emission value: xi = the natural logarithm of the measurement for the i-th vehicle of the sample; s = an estimate of the production standard deviation (after calculating the natural logarithm of the measurements); n = the current sample number. 4.1.1.3.2.4. Compute for the sample, the test statistic quantifying the sum of the standardised deviations to the limit and defined as: ►M1 Equation 4-3: ◄ 4.1.1.3.2.5. Then: 4.1.1.3.2.5.1. if the test statistic is greater than the pass decision number for the sample given in Table 4-1, a pass decision is reached; 4.1.1.3.2.5.2. if the test statistic is less than the fail decision number for the sample size given in Table 4-1, a fail decision is reached; 4.1.1.3.2.5.3. otherwise, an additional vehicle is tested according to Annex II(A) to Regulation (EU) No 168/2013 and the procedure is applied to the sample with one unit more. 4.1.1.3.2.5.4. Table 4-1 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are available Sample Size (cumulative number of vehicles tested) Pass Decision No Fail Decision No (a) (b) (c) 3 3,327 -4,724 4 3,261 -4,79 5 3,195 -4,856 6 3,129 -4,922 7 3,063 -4,988 8 2,997 -5,054 9 2,931 -5,12 10 2,865 -5,185 11 2,799 -5,251 12 2,733 -5,317 13 2,667 -5,383 14 2,601 -5,449 15 2,535 -5,515 16 2,469 -5,581 17 2,403 -5,647 18 2,337 -5,713 19 2,271 -5,779 20 2,205 -5,845 21 2,139 -5,911 22 2,073 -5,977 23 2,007 -6,043 24 1,941 -6,109 25 1,875 -6,175 26 1,809 -6,241 27 1,743 -6,307 28 1,677 -6,373 29 1,611 -6,439 30 1,545 -6,505 31 1,479 -6,571 32 -2,112 -2,112 4.1.1.3.3. Conformity of production when manufacturer’s statistical data remain unsatisfactory or unavailable 4.1.1.3.3.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s evidence of production standard deviation is either unsatisfactory or unavailable. 4.1.1.3.3.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.3.3. The measurement of ►M1 tailpipe pollutant and CO2 emissions ◄ is considered to be log normally distributed and should first be transformed by taking the natural logarithms. Let mo and m denote the minimum and maximum sample sizes respectively (mo = 3 and m = 32) and let n denote the current sample number. 4.1.1.3.3.4. If the natural logarithms of the measurements in the series are x1, x2, …, xj and L is the natural logarithm of the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval value, then define: ►M1 Equations 4-4: ◄ 4.1.1.3.3.5. Table 4-2 below shows values of the pass (An) and fail (Bn) decision numbers against current sample number. The test statistic is the ratio and shall be used to determine whether the series has passed or failed as follows: for mo ≤ n ≤ m: 4.1.1.3.3.5.1. pass the series if ; 4.1.1.3.3.5.2. fail the series if ; 4.1.1.3.3.5.3. take another measurement if Table 4-2 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are unsatisfactory or unavailable Sample Size (cumulative number of vehicles tested) Pass Decision No An Fail Decision No Bn (a) (b) (c) 3 0,80380 16,64743 4 0,76339 7,68627 5 0,72982 4,67136 6 0,69962 3,25573 7 0,67129 2,45431 8 0,64406 1,94369 9 0,61750 1,59105 10 0,59135 1,33295 11 0,56542 1,13566 12 0,53960 0,97970 13 0,51379 0,85307 14 0,48791 0,74801 15 0,46191 0,65928 16 0,43573 0,58321 17 0,40933 0,51718 18 0,38266 0,45922 19 0,35570 0,40788 20 0,32840 0,36203 21 0,30072 0,32078 22 0,27263 0,28343 23 0,24410 0,24943 24 0,21509 0,21831 25 0,18557 0,18970 26 0,15550 0,16328 27 0,12483 0,13880 28 0,09354 0,11603 29 0,06159 0,09480 30 0,02892 0,07493 31 0,00449 0,05629 32 0,03876 0,03876 4.1.1.3.3.6. RemarksThe following recursive formulae are useful for computing successive values of the test statistic: ►M1 Equations 4-5: ◄ (n = 2, 3, …; ; v1 = 0) 4.1.1.3.4. The type-approval authorities issuing the approval may at any time verify the methods applied in each production unit. 4.1.1.3.5. In every inspection, the records of tests and production monitoring shall be communicated to the visiting inspector. 4.1.1.3.6. The inspector may select at random the samples to be tested in the manufacturer’s laboratory. The minimum number of samples may be determined on the basis of the results of the manufacturer’s own checks. 4.1.1.3.7. When the quality standard does not seem satisfactory or when it seems necessary to verify the validity of the tests conducted under point 9.4.2.2, the inspector shall collect samples to be sent to the technical service which carried out the approval tests. 4.1.1.3.8. The type-approval authorities may carry out all the tests prescribed in this Annex. 4.1.1.4. Vehicles powered by a hybrid electric powertrainAs a general rule, measures to ensure the conformity of production with regard to ►M1 tailpipe pollutant and CO2 emissions ◄ , electric energy consumption and electric range from hybrid electric vehicles is checked on the basis of the description in the type-approval certificate conforming to the model in Article 30(2) of Regulation (EU) No 168/2013. Checks on production conformity are based on an assessment made by the approval authority of the manufacturer’s auditing procedure in order to ensure conformity of the vehicle type with respect to the emission of ►M1 tailpipe pollutant and CO2 emissions ◄ , electric energy consumption and range. If the authority is not satisfied with the standard of the manufacturer’s auditing procedure, it may require that verification tests be carried out on vehicles in production. Conformity for ►M1 tailpipe pollutant and CO2 emissions ◄ is checked using the statistical procedures described in points 4.1.1.3.1 to 4.1.1.3.3. Vehicles are tested according to the procedure described in Annex II(A) to Regulation (EU) No 168/2013. 4.1.1.5. Replacement pollution control devices 4.1.1.5.1. In order to test conformity as required above, a sample replacement pollution control device shall be taken from the production line of the type-approved vehicle. 4.1.1.5.2. Production will be regarded as being in conformity with the provisions of this Annex if a representative parent vehicle equipped with a pollution control device randomly selected from the production line complies with the applicable requirements set out in Article 23 of Regulation (EU) No 168/2013 on environmental performance. The performance of the propulsion fitted to the representative parent vehicle shall be measured according to Annex II(A) to Regulation (EU) No 168/2013 and shall not exceed the propulsion unit performance of the original pollution control device it replaces. 4.1.1.6. Actions to be taken in case of non-conformity of productionIf, during inspections, non-conformity is observed, the approval authority shall ensure that all necessary steps are taken to re-establish conformity of production as soon as possible. 4.1.1.7. Penalties for non-conformities of production 4.1.1.7.1. The approval granted in respect of a vehicle type may be withdrawn if the requirements in point 4.1.1.1 are not complied with. 4.1.1.7.2. If a Member State withdraws an approval it has previously granted, it shall forthwith notify the other Member States. 4.1.1.1. | Vehicles shall be manufactured in conformity with the approved vehicle type. 4.1.1.2. | Appropriate conformity of production checks shall be carried out to verify compliance with the conditions referred to in point 4.1.1.1. 4.1.1.3. | Vehicles powered by an internal combustion engine only: 4.1.1.3.1. As a general rule, measures to ensure the conformity of production with regard to ►M1 tailpipe pollutant and CO2 emissions ◄ from vehicles are to be checked on the basis of the description in the type-approval certificate conforming to the model set out in Article 30(2) of Regulation (EU) No 168/2013. The control of production conformity is based on an assessment by the approval authority of the manufacturer’s auditing procedure in order to ensure conformity of the manufactured vehicle with respect to the ►M1 tailpipe pollutant and CO2 emissions ◄ . If the approval authority is not satisfied with the standard of the manufacturer’s auditing procedure, it may require that verification tests be carried out on vehicles in production. 4.1.1.3.1.1. Measurements of the ►M1 tailpipe pollutant and CO2 emissions ◄ of a vehicle type that has had one or several extensions shall be carried out on the vehicle(s) available at the time of the test (vehicle(s) described in the first document or in subsequent extensions). 4.1.1.3.1.1.1. Conformity of the vehicle for type I, tailpipe emissions after cold start and type VII, CO2 emission test 4.1.1.3.1.1.1.1. Three vehicles shall be randomly selected from the series and tested according to the requirements set out in Articles 23 and 24 of Regulation (EU) No 168/2013. Deterioration factors shall be applied to the average of the test type I pollutant emission test results as follows: ▼M2 4.1.1.3.1.1.1.1.1. If the durability method set out in Article 23(3)(a) of Regulation (EU) No 168/2013 is applicable, the deterioration factors shall be calculated from the type I emission test results up to and including full distance referred to in Annex VII(A) to Regulation (EU) No 168/2013 and in accordance with the linear calculation method referred to in point 4.1.1.3.1.1.1.1.2. resulting in slope and offset values per emission constituent. The CoP pollutant emission results shall be calculated with the formula: Equation 4-1: Yfull = a (Xfull – XCoP) + YCoP where: a = slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull = durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP = Mileage of the CoP vehicle at moment of Type I CoP test; Yfull = CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP = pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.1.2. If the durability method set out in Article 23(3)(b) of Regulation (EU) No 168/2013 is applicable, the deterioration trend shall consist of the slope value a, as is reflected in point 4.1.1.3.1.1.1.1.1, per emission constituent calculated to comply with test type V in accordance with Annex V(A) to Regulation (EU) No 168/2013. Equation 4-1 shall be used to calculate the CoP emission results per pollutant emission constituent (Yfull). 4.1.1.3.1.1.1.1.3. If the durability method set out in Article 23(3)(c) of Regulation (EU) No 168/2013 is applicable, the fixed deterioration factors set out in Annex VII(B) to Regulation (EU) No 168/2013 shall be multiplied by the type test I result of the CoP vehicle (Ycop) to calculate the average CoP emission results per pollutant emission constituent (Yfull). ▼B 4.1.1.3.1.1.1.1.4. The average test type VII results (CO2 emissions, fuel/energy consumption and electric range if applicable) shall be lower than or equal to the declared values by the manufacturer at type-approval. 4.1.1.3.1.1.1.1.5. If the average emissions of the first two vehicles comply with the requirements laid down in point 4.1.1.3.1.1.1.1 then the production conformity is considered as satisfactory. 4.1.1.3.1.1.1.2. If the average emissions of the first two vehicles do not comply, the CoP procedure continues as follows: 4.1.1.3.1.1.1.2.1. If the authority is satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.2. 4.1.1.3.1.1.1.2.2. If the authority is not satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.3. 4.1.1.3.1.1.1.3. The production of a series is regarded as conforming or non-conforming, on the basis of tests on the three sampled vehicles, once a pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ according to the test criteria applied in the appropriate table. If no pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ , a test is carried out on an additional vehicle (see Figure 4-1). 4.1.1.3.1.1.1.4. In the case of periodically regenerating systems, the results shall be multiplied by the factor Ki obtained at the time when type-approval was granted. At the request of the manufacturer, testing may be carried out immediately after a regeneration has been completed. Figure 4-1 Pass/fail criteria for Type I, II and VII testing Text of image Test on three vehicles Computation of the test statistic According to the appropriate table does the test statistic agree with the criteria for failing the series ? Series Rejected According to the appropriate table does the test statistic agree with the criteria for passing the series ? Series Accepted Test of an additional vehicle 4.1.1.3.1.1.2. Notwithstanding the environmental requirements set out in Article 23 and 24 of Regulation (EU) No 168/2013, the tests will be carried out on vehicles which have travelled a maximum distance of 100 km after first start at the production line. 4.1.1.3.1.1.2.1. However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.2. Conformity of production when manufacturer’s statistical data are available 4.1.1.3.2.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s production standard deviation is again satisfactory. 4.1.1.3.2.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.2.3. The following procedure is used (see Figure 4-1): Let L be the natural logarithm of ►M1 tailpipe pollutant emission limits ◄ set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval emission value: xi = the natural logarithm of the measurement for the i-th vehicle of the sample; s = an estimate of the production standard deviation (after calculating the natural logarithm of the measurements); n = the current sample number. 4.1.1.3.2.4. Compute for the sample, the test statistic quantifying the sum of the standardised deviations to the limit and defined as: ►M1 Equation 4-3: ◄ 4.1.1.3.2.5. Then: 4.1.1.3.2.5.1. if the test statistic is greater than the pass decision number for the sample given in Table 4-1, a pass decision is reached; 4.1.1.3.2.5.2. if the test statistic is less than the fail decision number for the sample size given in Table 4-1, a fail decision is reached; 4.1.1.3.2.5.3. otherwise, an additional vehicle is tested according to Annex II(A) to Regulation (EU) No 168/2013 and the procedure is applied to the sample with one unit more. 4.1.1.3.2.5.4. Table 4-1 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are available Sample Size (cumulative number of vehicles tested) Pass Decision No Fail Decision No (a) (b) (c) 3 3,327 -4,724 4 3,261 -4,79 5 3,195 -4,856 6 3,129 -4,922 7 3,063 -4,988 8 2,997 -5,054 9 2,931 -5,12 10 2,865 -5,185 11 2,799 -5,251 12 2,733 -5,317 13 2,667 -5,383 14 2,601 -5,449 15 2,535 -5,515 16 2,469 -5,581 17 2,403 -5,647 18 2,337 -5,713 19 2,271 -5,779 20 2,205 -5,845 21 2,139 -5,911 22 2,073 -5,977 23 2,007 -6,043 24 1,941 -6,109 25 1,875 -6,175 26 1,809 -6,241 27 1,743 -6,307 28 1,677 -6,373 29 1,611 -6,439 30 1,545 -6,505 31 1,479 -6,571 32 -2,112 -2,112 4.1.1.3.3. Conformity of production when manufacturer’s statistical data remain unsatisfactory or unavailable 4.1.1.3.3.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s evidence of production standard deviation is either unsatisfactory or unavailable. 4.1.1.3.3.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.3.3. The measurement of ►M1 tailpipe pollutant and CO2 emissions ◄ is considered to be log normally distributed and should first be transformed by taking the natural logarithms. Let mo and m denote the minimum and maximum sample sizes respectively (mo = 3 and m = 32) and let n denote the current sample number. 4.1.1.3.3.4. If the natural logarithms of the measurements in the series are x1, x2, …, xj and L is the natural logarithm of the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval value, then define: ►M1 Equations 4-4: ◄ 4.1.1.3.3.5. Table 4-2 below shows values of the pass (An) and fail (Bn) decision numbers against current sample number. The test statistic is the ratio and shall be used to determine whether the series has passed or failed as follows: for mo ≤ n ≤ m: 4.1.1.3.3.5.1. pass the series if ; 4.1.1.3.3.5.2. fail the series if ; 4.1.1.3.3.5.3. take another measurement if Table 4-2 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are unsatisfactory or unavailable Sample Size (cumulative number of vehicles tested) Pass Decision No An Fail Decision No Bn (a) (b) (c) 3 0,80380 16,64743 4 0,76339 7,68627 5 0,72982 4,67136 6 0,69962 3,25573 7 0,67129 2,45431 8 0,64406 1,94369 9 0,61750 1,59105 10 0,59135 1,33295 11 0,56542 1,13566 12 0,53960 0,97970 13 0,51379 0,85307 14 0,48791 0,74801 15 0,46191 0,65928 16 0,43573 0,58321 17 0,40933 0,51718 18 0,38266 0,45922 19 0,35570 0,40788 20 0,32840 0,36203 21 0,30072 0,32078 22 0,27263 0,28343 23 0,24410 0,24943 24 0,21509 0,21831 25 0,18557 0,18970 26 0,15550 0,16328 27 0,12483 0,13880 28 0,09354 0,11603 29 0,06159 0,09480 30 0,02892 0,07493 31 0,00449 0,05629 32 0,03876 0,03876 4.1.1.3.3.6. RemarksThe following recursive formulae are useful for computing successive values of the test statistic: ►M1 Equations 4-5: ◄ (n = 2, 3, …; ; v1 = 0) 4.1.1.3.4. The type-approval authorities issuing the approval may at any time verify the methods applied in each production unit. 4.1.1.3.5. In every inspection, the records of tests and production monitoring shall be communicated to the visiting inspector. 4.1.1.3.6. The inspector may select at random the samples to be tested in the manufacturer’s laboratory. The minimum number of samples may be determined on the basis of the results of the manufacturer’s own checks. 4.1.1.3.7. When the quality standard does not seem satisfactory or when it seems necessary to verify the validity of the tests conducted under point 9.4.2.2, the inspector shall collect samples to be sent to the technical service which carried out the approval tests. 4.1.1.3.8. The type-approval authorities may carry out all the tests prescribed in this Annex. 4.1.1.3.1. | As a general rule, measures to ensure the conformity of production with regard to ►M1 tailpipe pollutant and CO2 emissions ◄ from vehicles are to be checked on the basis of the description in the type-approval certificate conforming to the model set out in Article 30(2) of Regulation (EU) No 168/2013. The control of production conformity is based on an assessment by the approval authority of the manufacturer’s auditing procedure in order to ensure conformity of the manufactured vehicle with respect to the ►M1 tailpipe pollutant and CO2 emissions ◄ . If the approval authority is not satisfied with the standard of the manufacturer’s auditing procedure, it may require that verification tests be carried out on vehicles in production. 4.1.1.3.1.1. Measurements of the ►M1 tailpipe pollutant and CO2 emissions ◄ of a vehicle type that has had one or several extensions shall be carried out on the vehicle(s) available at the time of the test (vehicle(s) described in the first document or in subsequent extensions). 4.1.1.3.1.1.1. Conformity of the vehicle for type I, tailpipe emissions after cold start and type VII, CO2 emission test 4.1.1.3.1.1.1.1. Three vehicles shall be randomly selected from the series and tested according to the requirements set out in Articles 23 and 24 of Regulation (EU) No 168/2013. Deterioration factors shall be applied to the average of the test type I pollutant emission test results as follows: ▼M2 4.1.1.3.1.1.1.1.1. If the durability method set out in Article 23(3)(a) of Regulation (EU) No 168/2013 is applicable, the deterioration factors shall be calculated from the type I emission test results up to and including full distance referred to in Annex VII(A) to Regulation (EU) No 168/2013 and in accordance with the linear calculation method referred to in point 4.1.1.3.1.1.1.1.2. resulting in slope and offset values per emission constituent. The CoP pollutant emission results shall be calculated with the formula: Equation 4-1: Yfull = a (Xfull – XCoP) + YCoP where: a = slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull = durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP = Mileage of the CoP vehicle at moment of Type I CoP test; Yfull = CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP = pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.1.2. If the durability method set out in Article 23(3)(b) of Regulation (EU) No 168/2013 is applicable, the deterioration trend shall consist of the slope value a, as is reflected in point 4.1.1.3.1.1.1.1.1, per emission constituent calculated to comply with test type V in accordance with Annex V(A) to Regulation (EU) No 168/2013. Equation 4-1 shall be used to calculate the CoP emission results per pollutant emission constituent (Yfull). 4.1.1.3.1.1.1.1.3. If the durability method set out in Article 23(3)(c) of Regulation (EU) No 168/2013 is applicable, the fixed deterioration factors set out in Annex VII(B) to Regulation (EU) No 168/2013 shall be multiplied by the type test I result of the CoP vehicle (Ycop) to calculate the average CoP emission results per pollutant emission constituent (Yfull). ▼B 4.1.1.3.1.1.1.1.4. The average test type VII results (CO2 emissions, fuel/energy consumption and electric range if applicable) shall be lower than or equal to the declared values by the manufacturer at type-approval. 4.1.1.3.1.1.1.1.5. If the average emissions of the first two vehicles comply with the requirements laid down in point 4.1.1.3.1.1.1.1 then the production conformity is considered as satisfactory. 4.1.1.3.1.1.1.2. If the average emissions of the first two vehicles do not comply, the CoP procedure continues as follows: 4.1.1.3.1.1.1.2.1. If the authority is satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.2. 4.1.1.3.1.1.1.2.2. If the authority is not satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.3. 4.1.1.3.1.1.1.3. The production of a series is regarded as conforming or non-conforming, on the basis of tests on the three sampled vehicles, once a pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ according to the test criteria applied in the appropriate table. If no pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ , a test is carried out on an additional vehicle (see Figure 4-1). 4.1.1.3.1.1.1.4. In the case of periodically regenerating systems, the results shall be multiplied by the factor Ki obtained at the time when type-approval was granted. At the request of the manufacturer, testing may be carried out immediately after a regeneration has been completed. Figure 4-1 Pass/fail criteria for Type I, II and VII testing Text of image Test on three vehicles Computation of the test statistic According to the appropriate table does the test statistic agree with the criteria for failing the series ? Series Rejected According to the appropriate table does the test statistic agree with the criteria for passing the series ? Series Accepted Test of an additional vehicle 4.1.1.3.1.1.2. Notwithstanding the environmental requirements set out in Article 23 and 24 of Regulation (EU) No 168/2013, the tests will be carried out on vehicles which have travelled a maximum distance of 100 km after first start at the production line. 4.1.1.3.1.1.2.1. However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.1.1. | Measurements of the ►M1 tailpipe pollutant and CO2 emissions ◄ of a vehicle type that has had one or several extensions shall be carried out on the vehicle(s) available at the time of the test (vehicle(s) described in the first document or in subsequent extensions). 4.1.1.3.1.1.1. Conformity of the vehicle for type I, tailpipe emissions after cold start and type VII, CO2 emission test 4.1.1.3.1.1.1.1. Three vehicles shall be randomly selected from the series and tested according to the requirements set out in Articles 23 and 24 of Regulation (EU) No 168/2013. Deterioration factors shall be applied to the average of the test type I pollutant emission test results as follows: ▼M2 4.1.1.3.1.1.1.1.1. If the durability method set out in Article 23(3)(a) of Regulation (EU) No 168/2013 is applicable, the deterioration factors shall be calculated from the type I emission test results up to and including full distance referred to in Annex VII(A) to Regulation (EU) No 168/2013 and in accordance with the linear calculation method referred to in point 4.1.1.3.1.1.1.1.2. resulting in slope and offset values per emission constituent. The CoP pollutant emission results shall be calculated with the formula: Equation 4-1: Yfull = a (Xfull – XCoP) + YCoP where: a = slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull = durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP = Mileage of the CoP vehicle at moment of Type I CoP test; Yfull = CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP = pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.1.2. If the durability method set out in Article 23(3)(b) of Regulation (EU) No 168/2013 is applicable, the deterioration trend shall consist of the slope value a, as is reflected in point 4.1.1.3.1.1.1.1.1, per emission constituent calculated to comply with test type V in accordance with Annex V(A) to Regulation (EU) No 168/2013. Equation 4-1 shall be used to calculate the CoP emission results per pollutant emission constituent (Yfull). 4.1.1.3.1.1.1.1.3. If the durability method set out in Article 23(3)(c) of Regulation (EU) No 168/2013 is applicable, the fixed deterioration factors set out in Annex VII(B) to Regulation (EU) No 168/2013 shall be multiplied by the type test I result of the CoP vehicle (Ycop) to calculate the average CoP emission results per pollutant emission constituent (Yfull). ▼B 4.1.1.3.1.1.1.1.4. The average test type VII results (CO2 emissions, fuel/energy consumption and electric range if applicable) shall be lower than or equal to the declared values by the manufacturer at type-approval. 4.1.1.3.1.1.1.1.5. If the average emissions of the first two vehicles comply with the requirements laid down in point 4.1.1.3.1.1.1.1 then the production conformity is considered as satisfactory. 4.1.1.3.1.1.1.2. If the average emissions of the first two vehicles do not comply, the CoP procedure continues as follows: 4.1.1.3.1.1.1.2.1. If the authority is satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.2. 4.1.1.3.1.1.1.2.2. If the authority is not satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.3. 4.1.1.3.1.1.1.3. The production of a series is regarded as conforming or non-conforming, on the basis of tests on the three sampled vehicles, once a pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ according to the test criteria applied in the appropriate table. If no pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ , a test is carried out on an additional vehicle (see Figure 4-1). 4.1.1.3.1.1.1.4. In the case of periodically regenerating systems, the results shall be multiplied by the factor Ki obtained at the time when type-approval was granted. At the request of the manufacturer, testing may be carried out immediately after a regeneration has been completed. Figure 4-1 Pass/fail criteria for Type I, II and VII testing Text of image Test on three vehicles Computation of the test statistic According to the appropriate table does the test statistic agree with the criteria for failing the series ? Series Rejected According to the appropriate table does the test statistic agree with the criteria for passing the series ? Series Accepted Test of an additional vehicle 4.1.1.3.1.1.2. Notwithstanding the environmental requirements set out in Article 23 and 24 of Regulation (EU) No 168/2013, the tests will be carried out on vehicles which have travelled a maximum distance of 100 km after first start at the production line. 4.1.1.3.1.1.2.1. However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.1.1.1.1. | Three vehicles shall be randomly selected from the series and tested according to the requirements set out in Articles 23 and 24 of Regulation (EU) No 168/2013. Deterioration factors shall be applied to the average of the test type I pollutant emission test results as follows: ▼M2 4.1.1.3.1.1.1.1.1. If the durability method set out in Article 23(3)(a) of Regulation (EU) No 168/2013 is applicable, the deterioration factors shall be calculated from the type I emission test results up to and including full distance referred to in Annex VII(A) to Regulation (EU) No 168/2013 and in accordance with the linear calculation method referred to in point 4.1.1.3.1.1.1.1.2. resulting in slope and offset values per emission constituent. The CoP pollutant emission results shall be calculated with the formula: Equation 4-1: Yfull = a (Xfull – XCoP) + YCoP where: a = slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull = durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP = Mileage of the CoP vehicle at moment of Type I CoP test; Yfull = CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP = pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.1.2. If the durability method set out in Article 23(3)(b) of Regulation (EU) No 168/2013 is applicable, the deterioration trend shall consist of the slope value a, as is reflected in point 4.1.1.3.1.1.1.1.1, per emission constituent calculated to comply with test type V in accordance with Annex V(A) to Regulation (EU) No 168/2013. Equation 4-1 shall be used to calculate the CoP emission results per pollutant emission constituent (Yfull). 4.1.1.3.1.1.1.1.3. If the durability method set out in Article 23(3)(c) of Regulation (EU) No 168/2013 is applicable, the fixed deterioration factors set out in Annex VII(B) to Regulation (EU) No 168/2013 shall be multiplied by the type test I result of the CoP vehicle (Ycop) to calculate the average CoP emission results per pollutant emission constituent (Yfull). ▼B 4.1.1.3.1.1.1.1.4. The average test type VII results (CO2 emissions, fuel/energy consumption and electric range if applicable) shall be lower than or equal to the declared values by the manufacturer at type-approval. 4.1.1.3.1.1.1.1.5. If the average emissions of the first two vehicles comply with the requirements laid down in point 4.1.1.3.1.1.1.1 then the production conformity is considered as satisfactory. a | = | slope value ((mg/km)/km) determined in accordance with test type V set out in Annex V(A) to Regulation (EU) No 168/2013; XFull | = | durability mileage (km) as set out in Annex VII to Regulation (EU) No 168/2013; XCoP | = | Mileage of the CoP vehicle at moment of Type I CoP test; Yfull | = | CoP emission result per pollutant emission constituent in mg/km. The average CoP results shall be lower than the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013; YCoP | = | pollutant emission (THC, CO, NOx, NMHC and PM if applicable) test result (mg/km) per emission constituent of test type I with CoP vehicle. 4.1.1.3.1.1.1.2. | If the average emissions of the first two vehicles do not comply, the CoP procedure continues as follows: 4.1.1.3.1.1.1.2.1. If the authority is satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.2. 4.1.1.3.1.1.1.2.2. If the authority is not satisfied with the production standard deviation given by the manufacturer, the tests are carried out according to point 4.1.1.3.3. 4.1.1.3.1.1.1.3. | The production of a series is regarded as conforming or non-conforming, on the basis of tests on the three sampled vehicles, once a pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ according to the test criteria applied in the appropriate table. If no pass or fail decision is reached for ►M1 tailpipe pollutant and CO2 emissions ◄ , a test is carried out on an additional vehicle (see Figure 4-1). 4.1.1.3.1.1.1.4. | In the case of periodically regenerating systems, the results shall be multiplied by the factor Ki obtained at the time when type-approval was granted. At the request of the manufacturer, testing may be carried out immediately after a regeneration has been completed. Figure 4-1 Pass/fail criteria for Type I, II and VII testing Text of image Test on three vehicles Computation of the test statistic According to the appropriate table does the test statistic agree with the criteria for failing the series ? Series Rejected According to the appropriate table does the test statistic agree with the criteria for passing the series ? Series Accepted Test of an additional vehicle 4.1.1.3.1.1.2. | Notwithstanding the environmental requirements set out in Article 23 and 24 of Regulation (EU) No 168/2013, the tests will be carried out on vehicles which have travelled a maximum distance of 100 km after first start at the production line. 4.1.1.3.1.1.2.1. However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.1.1.2.1. | However, at the request of the manufacturer, the tests will be carried out on vehicles which have been run in a maximum of 1 000 km. In this case, the running-in procedure will be conducted by the manufacturer, who shall undertake not to make any adjustments to those vehicles. 4.1.1.3.1.1.2.2. | If the manufacturer asks to be allowed to conduct a running-in procedure (‘x’ km, where x ≤ 1 000 km), it may be carried out as follows: The ►M1 tailpipe pollutant and CO2 emissions ◄ will be measured at maximum 100 km after first start on the production line and at ‘x’ km on the first tested vehicle (which can be the type-approval vehicle); The evolution coefficient (EC) of the emissions between 100 km and ‘x’ km will be calculated as follows: Equation 4-2: The value of EC may be less than 1. The subsequent vehicles will not be subjected to the running-in procedure, but their 100 km emissions will be modified by the EC. In this case, the values to be taken will be: The value at ‘x’ km for the first vehicle; The values at maximum 100 km multiplied by the evolution coefficient (EC) for the subsequent vehicles. 4.1.1.3.1.1.2.3. | As an alternative to this procedure, the vehicle manufacturer can use a fixed EC of 0,92 and multiply all values of ►M1 tailpipe pollutant and CO2 emissions ◄ measured at zero km by this factor. 4.1.1.3.1.1.2.4. | Tests for conformity of production may be performed with a commercial fuel of which the C3/C4 ratio lies between those of the reference fuels referred to in Annex II(A1) to Regulation (EU) No 168/2013 in the case of LPG, or of which the Wobbe index lies between those of the extreme reference fuels in the case of NG or H2NG. In that case, a fuel analysis shall be presented to the approval authority. 4.1.1.3.2. | Conformity of production when manufacturer’s statistical data are available 4.1.1.3.2.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s production standard deviation is again satisfactory. 4.1.1.3.2.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.2.3. The following procedure is used (see Figure 4-1): Let L be the natural logarithm of ►M1 tailpipe pollutant emission limits ◄ set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval emission value: xi = the natural logarithm of the measurement for the i-th vehicle of the sample; s = an estimate of the production standard deviation (after calculating the natural logarithm of the measurements); n = the current sample number. 4.1.1.3.2.4. Compute for the sample, the test statistic quantifying the sum of the standardised deviations to the limit and defined as: ►M1 Equation 4-3: ◄ 4.1.1.3.2.5. Then: 4.1.1.3.2.5.1. if the test statistic is greater than the pass decision number for the sample given in Table 4-1, a pass decision is reached; 4.1.1.3.2.5.2. if the test statistic is less than the fail decision number for the sample size given in Table 4-1, a fail decision is reached; 4.1.1.3.2.5.3. otherwise, an additional vehicle is tested according to Annex II(A) to Regulation (EU) No 168/2013 and the procedure is applied to the sample with one unit more. 4.1.1.3.2.5.4. Table 4-1 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are available Sample Size (cumulative number of vehicles tested) Pass Decision No Fail Decision No (a) (b) (c) 3 3,327 -4,724 4 3,261 -4,79 5 3,195 -4,856 6 3,129 -4,922 7 3,063 -4,988 8 2,997 -5,054 9 2,931 -5,12 10 2,865 -5,185 11 2,799 -5,251 12 2,733 -5,317 13 2,667 -5,383 14 2,601 -5,449 15 2,535 -5,515 16 2,469 -5,581 17 2,403 -5,647 18 2,337 -5,713 19 2,271 -5,779 20 2,205 -5,845 21 2,139 -5,911 22 2,073 -5,977 23 2,007 -6,043 24 1,941 -6,109 25 1,875 -6,175 26 1,809 -6,241 27 1,743 -6,307 28 1,677 -6,373 29 1,611 -6,439 30 1,545 -6,505 31 1,479 -6,571 32 -2,112 -2,112 4.1.1.3.2.1. | The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s production standard deviation is again satisfactory. 4.1.1.3.2.2. | With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.2.3. | The following procedure is used (see Figure 4-1): Let L be the natural logarithm of ►M1 tailpipe pollutant emission limits ◄ set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval emission value: xi = the natural logarithm of the measurement for the i-th vehicle of the sample; s = an estimate of the production standard deviation (after calculating the natural logarithm of the measurements); n = the current sample number. xi | = | the natural logarithm of the measurement for the i-th vehicle of the sample; s | = | an estimate of the production standard deviation (after calculating the natural logarithm of the measurements); n | = | the current sample number. 4.1.1.3.2.4. | Compute for the sample, the test statistic quantifying the sum of the standardised deviations to the limit and defined as: ►M1 Equation 4-3: ◄ 4.1.1.3.2.5. | Then: 4.1.1.3.2.5.1. if the test statistic is greater than the pass decision number for the sample given in Table 4-1, a pass decision is reached; 4.1.1.3.2.5.2. if the test statistic is less than the fail decision number for the sample size given in Table 4-1, a fail decision is reached; 4.1.1.3.2.5.3. otherwise, an additional vehicle is tested according to Annex II(A) to Regulation (EU) No 168/2013 and the procedure is applied to the sample with one unit more. 4.1.1.3.2.5.4. Table 4-1 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are available Sample Size (cumulative number of vehicles tested) Pass Decision No Fail Decision No (a) (b) (c) 3 3,327 -4,724 4 3,261 -4,79 5 3,195 -4,856 6 3,129 -4,922 7 3,063 -4,988 8 2,997 -5,054 9 2,931 -5,12 10 2,865 -5,185 11 2,799 -5,251 12 2,733 -5,317 13 2,667 -5,383 14 2,601 -5,449 15 2,535 -5,515 16 2,469 -5,581 17 2,403 -5,647 18 2,337 -5,713 19 2,271 -5,779 20 2,205 -5,845 21 2,139 -5,911 22 2,073 -5,977 23 2,007 -6,043 24 1,941 -6,109 25 1,875 -6,175 26 1,809 -6,241 27 1,743 -6,307 28 1,677 -6,373 29 1,611 -6,439 30 1,545 -6,505 31 1,479 -6,571 32 -2,112 -2,112 Sample Size (cumulative number of vehicles tested) | Pass Decision No | Fail Decision No (a) | (b) | (c) 3 | 3,327 | -4,724 4 | 3,261 | -4,79 5 | 3,195 | -4,856 6 | 3,129 | -4,922 7 | 3,063 | -4,988 8 | 2,997 | -5,054 9 | 2,931 | -5,12 10 | 2,865 | -5,185 11 | 2,799 | -5,251 12 | 2,733 | -5,317 13 | 2,667 | -5,383 14 | 2,601 | -5,449 15 | 2,535 | -5,515 16 | 2,469 | -5,581 17 | 2,403 | -5,647 18 | 2,337 | -5,713 19 | 2,271 | -5,779 20 | 2,205 | -5,845 21 | 2,139 | -5,911 22 | 2,073 | -5,977 23 | 2,007 | -6,043 24 | 1,941 | -6,109 25 | 1,875 | -6,175 26 | 1,809 | -6,241 27 | 1,743 | -6,307 28 | 1,677 | -6,373 29 | 1,611 | -6,439 30 | 1,545 | -6,505 31 | 1,479 | -6,571 32 | -2,112 | -2,112 4.1.1.3.3. | Conformity of production when manufacturer’s statistical data remain unsatisfactory or unavailable 4.1.1.3.3.1. The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s evidence of production standard deviation is either unsatisfactory or unavailable. 4.1.1.3.3.2. With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.3.3. The measurement of ►M1 tailpipe pollutant and CO2 emissions ◄ is considered to be log normally distributed and should first be transformed by taking the natural logarithms. Let mo and m denote the minimum and maximum sample sizes respectively (mo = 3 and m = 32) and let n denote the current sample number. 4.1.1.3.3.4. If the natural logarithms of the measurements in the series are x1, x2, …, xj and L is the natural logarithm of the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval value, then define: ►M1 Equations 4-4: ◄ 4.1.1.3.3.5. Table 4-2 below shows values of the pass (An) and fail (Bn) decision numbers against current sample number. The test statistic is the ratio and shall be used to determine whether the series has passed or failed as follows: for mo ≤ n ≤ m: 4.1.1.3.3.5.1. pass the series if ; 4.1.1.3.3.5.2. fail the series if ; 4.1.1.3.3.5.3. take another measurement if Table 4-2 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are unsatisfactory or unavailable Sample Size (cumulative number of vehicles tested) Pass Decision No An Fail Decision No Bn (a) (b) (c) 3 0,80380 16,64743 4 0,76339 7,68627 5 0,72982 4,67136 6 0,69962 3,25573 7 0,67129 2,45431 8 0,64406 1,94369 9 0,61750 1,59105 10 0,59135 1,33295 11 0,56542 1,13566 12 0,53960 0,97970 13 0,51379 0,85307 14 0,48791 0,74801 15 0,46191 0,65928 16 0,43573 0,58321 17 0,40933 0,51718 18 0,38266 0,45922 19 0,35570 0,40788 20 0,32840 0,36203 21 0,30072 0,32078 22 0,27263 0,28343 23 0,24410 0,24943 24 0,21509 0,21831 25 0,18557 0,18970 26 0,15550 0,16328 27 0,12483 0,13880 28 0,09354 0,11603 29 0,06159 0,09480 30 0,02892 0,07493 31 0,00449 0,05629 32 0,03876 0,03876 4.1.1.3.3.6. RemarksThe following recursive formulae are useful for computing successive values of the test statistic: ►M1 Equations 4-5: ◄ (n = 2, 3, …; ; v1 = 0) 4.1.1.3.3.1. | The following sections describe the procedure to be used to verify the ►M1 tailpipe pollutant and CO2 emissions ◄ conformity of production requirements when the manufacturer’s evidence of production standard deviation is either unsatisfactory or unavailable. 4.1.1.3.3.2. | With a minimum sample size of three, the sampling procedure is set so that the probability of a lot passing a test with 40 % of the production defective is 0,95 (producer’s risk = 5 %), while the probability of a lot being accepted with 65 % of the production defective is 0,1 (consumer’s risk = 10 %). 4.1.1.3.3.3. | The measurement of ►M1 tailpipe pollutant and CO2 emissions ◄ is considered to be log normally distributed and should first be transformed by taking the natural logarithms. Let mo and m denote the minimum and maximum sample sizes respectively (mo = 3 and m = 32) and let n denote the current sample number. 4.1.1.3.3.4. | If the natural logarithms of the measurements in the series are x1, x2, …, xj and L is the natural logarithm of the pollutant emission limits set out in Annex VI(A) to Regulation (EU) No 168/2013 and the declared CO2 type-approval value, then define: ►M1 Equations 4-4: ◄ 4.1.1.3.3.5. | Table 4-2 below shows values of the pass (An) and fail (Bn) decision numbers against current sample number. The test statistic is the ratio and shall be used to determine whether the series has passed or failed as follows: for mo ≤ n ≤ m: 4.1.1.3.3.5.1. pass the series if ; 4.1.1.3.3.5.2. fail the series if ; 4.1.1.3.3.5.3. take another measurement if Table 4-2 Pass/fail decision depending on sample size; conformity of production when manufacturer’s statistical data are unsatisfactory or unavailable Sample Size (cumulative number of vehicles tested) Pass Decision No An Fail Decision No Bn (a) (b) (c) 3 0,80380 16,64743 4 0,76339 7,68627 5 0,72982 4,67136 6 0,69962 3,25573 7 0,67129 2,45431 8 0,64406 1,94369 9 0,61750 1,59105 10 0,59135 1,33295 11 0,56542 1,13566 12 0,53960 0,97970 13 0,51379 0,85307 14 0,48791 0,74801 15 0,46191 0,65928 16 0,43573 0,58321 17 0,40933 0,51718 18 0,38266 0,45922 19 0,35570 0,40788 20 0,32840 0,36203 21 0,30072 0,32078 22 0,27263 0,28343 23 0,24410 0,24943 24 0,21509 0,21831 25 0,18557 0,18970 26 0,15550 0,16328 27 0,12483 0,13880 28 0,09354 0,11603 29 0,06159 0,09480 30 0,02892 0,07493 31 0,00449 0,05629 32 0,03876 0,03876 Sample Size (cumulative number of vehicles tested) | Pass Decision No An | Fail Decision No Bn (a) | (b) | (c) 3 | 0,80380 | 16,64743 4 | 0,76339 | 7,68627 5 | 0,72982 | 4,67136 6 | 0,69962 | 3,25573 7 | 0,67129 | 2,45431 8 | 0,64406 | 1,94369 9 | 0,61750 | 1,59105 10 | 0,59135 | 1,33295 11 | 0,56542 | 1,13566 12 | 0,53960 | 0,97970 13 | 0,51379 | 0,85307 14 | 0,48791 | 0,74801 15 | 0,46191 | 0,65928 16 | 0,43573 | 0,58321 17 | 0,40933 | 0,51718 18 | 0,38266 | 0,45922 19 | 0,35570 | 0,40788 20 | 0,32840 | 0,36203 21 | 0,30072 | 0,32078 22 | 0,27263 | 0,28343 23 | 0,24410 | 0,24943 24 | 0,21509 | 0,21831 25 | 0,18557 | 0,18970 26 | 0,15550 | 0,16328 27 | 0,12483 | 0,13880 28 | 0,09354 | 0,11603 29 | 0,06159 | 0,09480 30 | 0,02892 | 0,07493 31 | 0,00449 | 0,05629 32 | 0,03876 | 0,03876 4.1.1.3.3.6. | RemarksThe following recursive formulae are useful for computing successive values of the test statistic: ►M1 Equations 4-5: ◄ (n = 2, 3, …; ; v1 = 0) 4.1.1.3.4. | The type-approval authorities issuing the approval may at any time verify the methods applied in each production unit. 4.1.1.3.5. | In every inspection, the records of tests and production monitoring shall be communicated to the visiting inspector. 4.1.1.3.6. | The inspector may select at random the samples to be tested in the manufacturer’s laboratory. The minimum number of samples may be determined on the basis of the results of the manufacturer’s own checks. 4.1.1.3.7. | When the quality standard does not seem satisfactory or when it seems necessary to verify the validity of the tests conducted under point 9.4.2.2, the inspector shall collect samples to be sent to the technical service which carried out the approval tests. 4.1.1.3.8. | The type-approval authorities may carry out all the tests prescribed in this Annex. 4.1.1.4. | Vehicles powered by a hybrid electric powertrainAs a general rule, measures to ensure the conformity of production with regard to ►M1 tailpipe pollutant and CO2 emissions ◄ , electric energy consumption and electric range from hybrid electric vehicles is checked on the basis of the description in the type-approval certificate conforming to the model in Article 30(2) of Regulation (EU) No 168/2013. Checks on production conformity are based on an assessment made by the approval authority of the manufacturer’s auditing procedure in order to ensure conformity of the vehicle type with respect to the emission of ►M1 tailpipe pollutant and CO2 emissions ◄ , electric energy consumption and range. If the authority is not satisfied with the standard of the manufacturer’s auditing procedure, it may require that verification tests be carried out on vehicles in production. Conformity for ►M1 tailpipe pollutant and CO2 emissions ◄ is checked using the statistical procedures described in points 4.1.1.3.1 to 4.1.1.3.3. Vehicles are tested according to the procedure described in Annex II(A) to Regulation (EU) No 168/2013. 4.1.1.5. | Replacement pollution control devices 4.1.1.5.1. In order to test conformity as required above, a sample replacement pollution control device shall be taken from the production line of the type-approved vehicle. 4.1.1.5.2. Production will be regarded as being in conformity with the provisions of this Annex if a representative parent vehicle equipped with a pollution control device randomly selected from the production line complies with the applicable requirements set out in Article 23 of Regulation (EU) No 168/2013 on environmental performance. The performance of the propulsion fitted to the representative parent vehicle shall be measured according to Annex II(A) to Regulation (EU) No 168/2013 and shall not exceed the propulsion unit performance of the original pollution control device it replaces. 4.1.1.5.1. | In order to test conformity as required above, a sample replacement pollution control device shall be taken from the production line of the type-approved vehicle. 4.1.1.5.2. | Production will be regarded as being in conformity with the provisions of this Annex if a representative parent vehicle equipped with a pollution control device randomly selected from the production line complies with the applicable requirements set out in Article 23 of Regulation (EU) No 168/2013 on environmental performance. The performance of the propulsion fitted to the representative parent vehicle shall be measured according to Annex II(A) to Regulation (EU) No 168/2013 and shall not exceed the propulsion unit performance of the original pollution control device it replaces. 4.1.1.6. | Actions to be taken in case of non-conformity of productionIf, during inspections, non-conformity is observed, the approval authority shall ensure that all necessary steps are taken to re-establish conformity of production as soon as possible. 4.1.1.7. | Penalties for non-conformities of production 4.1.1.7.1. The approval granted in respect of a vehicle type may be withdrawn if the requirements in point 4.1.1.1 are not complied with. 4.1.1.7.2. If a Member State withdraws an approval it has previously granted, it shall forthwith notify the other Member States. 4.1.1.7.1. | The approval granted in respect of a vehicle type may be withdrawn if the requirements in point 4.1.1.1 are not complied with. 4.1.1.7.2. | If a Member State withdraws an approval it has previously granted, it shall forthwith notify the other Member States. 4.1.2. | Conformity of production for test type IV, evaporative emissionsFor routine end-of-production-line testing, the manufacturer may demonstrate compliance by sampling vehicles which shall meet the following requirements. Alternatively, the full test procedure described in this Annex shall be carried out. At the request of the manufacturer an alternative test procedure may be used, if the procedure has been presented to and has been accepted during the type approval procedure by the technical service to the satisfaction of the approval authority. 4.1.2.1. Test for leakage 4.1.2.1.1. Vents to the atmosphere from the evaporative emission control system shall be isolated. 4.1.2.1.2. A pressure of 3,7 kPa ± 0,1 kPa (370 ± 10 mm of H2O) shall be applied to the fuel system. 4.1.2.1.3. The pressure shall be allowed to stabilise prior to isolating the fuel system from the pressure source. 4.1.2.1.4. Following isolation of the fuel system, the pressure shall drop by no more than 0,5 kPa (50 mm of H2O) in five minutes. 4.1.2.2. Test for venting 4.1.2.2.1. Vents to the atmosphere from the emission control shall be isolated. 4.1.2.2.2. A pressure of 3,7 kPa ± 0,1 kPa (370 ± 10 mm of H2O) shall be applied to the fuel system. 4.1.2.2.3. The pressure shall be allowed to stabilise before the fuel system is isolated from the pressure source. 4.1.2.2.4. The venting outlets from the emission control systems to the atmosphere shall be reinstated to the production condition. 4.1.2.2.5. The pressure of the fuel system shall drop to below 1,0 kPa (100 mm of H2O) within two minutes. 4.1.2.3. Purge test 4.1.2.3.1. Equipment capable of detecting an airflow rate of 0,25 litre in one minute shall be attached to the purge inlet and a pressure vessel of sufficient size to have negligible effect on the purge system shall be connected via a switching valve to the purge inlet, or alternatively: 4.1.2.3.2. The manufacturer may use a flow meter of his own choice, if acceptable to the approval authority. 4.1.2.3.3. The vehicle shall be operated in such a manner that any design feature of the purge system that could restrict purge operation is detected and the circumstances noted. 4.1.2.3.4. Whilst the engine is operating within the bounds noted in this point the air flow shall be determined by either: 4.1.2.3.4.1. The device being switched in a pressure drop from atmospheric to a level indicating that a volume of 0,25 litre of air has flowed into the evaporative emission control system within one minute; or 4.1.2.3.4.2. An alternative flow measuring device with a detectable reading of no less than 0,25 litre per minute. 4.1.2.3.4.3. At the request of the manufacturer, an alternative purge test procedure can be used if the procedure has been presented to, and accepted by, the technical service during the type-approval procedure. 4.1.2.4. Control Methods 4.1.2.4.1. The approval authority which has granted type-approval may at any time verify the conformity control methods applicable to each production unit. 4.1.2.1.1. | Vents to the atmosphere from the evaporative emission control system shall be isolated. 4.1.2.1.2. | A pressure of 3,7 kPa ± 0,1 kPa (370 ± 10 mm of H2O) shall be applied to the fuel system. 4.1.2.1.3. | The pressure shall be allowed to stabilise prior to isolating the fuel system from the pressure source. 4.1.2.1.4. | Following isolation of the fuel system, the pressure shall drop by no more than 0,5 kPa (50 mm of H2O) in five minutes. 4.1.2.2.1. | Vents to the atmosphere from the emission control shall be isolated. 4.1.2.2.2. | A pressure of 3,7 kPa ± 0,1 kPa (370 ± 10 mm of H2O) shall be applied to the fuel system. 4.1.2.2.3. | The pressure shall be allowed to stabilise before the fuel system is isolated from the pressure source. 4.1.2.2.4. | The venting outlets from the emission control systems to the atmosphere shall be reinstated to the production condition. 4.1.2.2.5. | The pressure of the fuel system shall drop to below 1,0 kPa (100 mm of H2O) within two minutes. 4.1.2.3.1. | Equipment capable of detecting an airflow rate of 0,25 litre in one minute shall be attached to the purge inlet and a pressure vessel of sufficient size to have negligible effect on the purge system shall be connected via a switching valve to the purge inlet, or alternatively: 4.1.2.3.2. | The manufacturer may use a flow meter of his own choice, if acceptable to the approval authority. 4.1.2.3.3. | The vehicle shall be operated in such a manner that any design feature of the purge system that could restrict purge operation is detected and the circumstances noted. 4.1.2.3.4. | Whilst the engine is operating within the bounds noted in this point the air flow shall be determined by either: 4.1.2.3.4.1. The device being switched in a pressure drop from atmospheric to a level indicating that a volume of 0,25 litre of air has flowed into the evaporative emission control system within one minute; or 4.1.2.3.4.2. An alternative flow measuring device with a detectable reading of no less than 0,25 litre per minute. 4.1.2.3.4.3. At the request of the manufacturer, an alternative purge test procedure can be used if the procedure has been presented to, and accepted by, the technical service during the type-approval procedure. 4.1.2.4.1. | The approval authority which has granted type-approval may at any time verify the conformity control methods applicable to each production unit. 4.1.3. | Test type VIII on sound level4.1.3.1. Vehicle conformity regarding sound level Any vehicle manufactured shall conform to an approved type of vehicle and shall be equipped with the silencer with which it was type-approved and satisfy the requirements of Article 23 and Annex VI(D) to Regulation (EU) No 168/2013 relating to the type of vehicle concerned. 4.1.3.1.1. In order to test conformity as required above, a sample vehicle shall be taken from the production line of the type approved pursuant to this point 4.1.3. Production will be regarded as conforming to the provisions of this point if the sound level measured using the test method referred to in Annex VI(D) to Regulation (EU) No 168/2013 does not exceed by more than 3 dB(A) the value measured at the time of type-approval, nor by more than 1 dB(A) the limits laid down in this point. 4.1.3.2. Conformity of production of a non-original replacement exhaust system 4.1.3.2.1. Any exhaust system manufactured shall conform to a type approved pursuant to this point and satisfy the requirements of Annex VI(D) to Regulation (EU) No 168/2013 relating to the type of vehicle for which it is intended. 4.1.3.2.2. In order to test conformity as required above, a sample exhaust will be taken from the production line of the type approved pursuant to this point 4.1.3. 4.1.3.2.3. Production will be regarded as complying with this point 4.1.3 if the requirements of Annex VI(D) to Regulation (EU) No 168/2013 are satisfied and if the sound level measured using the test method referred to in that Annex does not exceed by more than 3 dB(A) the value measured at the time of type-approval. 4.1.3.1.1. | In order to test conformity as required above, a sample vehicle shall be taken from the production line of the type approved pursuant to this point 4.1.3. Production will be regarded as conforming to the provisions of this point if the sound level measured using the test method referred to in Annex VI(D) to Regulation (EU) No 168/2013 does not exceed by more than 3 dB(A) the value measured at the time of type-approval, nor by more than 1 dB(A) the limits laid down in this point. 4.1.3.2.1. | Any exhaust system manufactured shall conform to a type approved pursuant to this point and satisfy the requirements of Annex VI(D) to Regulation (EU) No 168/2013 relating to the type of vehicle for which it is intended. 4.1.3.2.2. | In order to test conformity as required above, a sample exhaust will be taken from the production line of the type approved pursuant to this point 4.1.3. 4.1.3.2.3. | Production will be regarded as complying with this point 4.1.3 if the requirements of Annex VI(D) to Regulation (EU) No 168/2013 are satisfied and if the sound level measured using the test method referred to in that Annex does not exceed by more than 3 dB(A) the value measured at the time of type-approval. 4.1.4. | Conformity of production (CoP) requirements regarding maximum design vehicle speed, maximum torque, maximum continuous rated power and maximum peak power4.1.4.1. Maximum vehicle speed measurement tolerances during conformity of production (CoP) testing During a production conformity check, the maximum design vehicle speed may differ by ± 5 % from the value determined during the type-approval test. 4.1.4.2. Maximum torque, maximum continuous rated power, maximum net power and maximum peak power tolerances during CoP testing Table 4-3 Measurement tolerance on maximum torque, maximum continuous rated power, maximum net power and maximum peak power dependent on measured power Measured power Acceptable tolerance on maximum torque, maximum continuous rated power, maximum net power and maximum peak power < 1 kW ≤ 20 % 1 kW < measured power < 11 kW ≤ 10 % > 11 kW ≤ 5 % Measured power | Acceptable tolerance on maximum torque, maximum continuous rated power, maximum net power and maximum peak power < 1 kW | ≤ 20 % 1 kW < measured power < 11 kW | ≤ 10 % > 11 kW | ≤ 5 % 4.1.5. | Conformity of production (CoP) requirements regarding the mass in running order.The mass in running order of an L-category vehicle may deviate from the nominal value by no more than 8 % as regards the permissible lower and upper deviations, which is the negative and positive deviation around the declared nominal value of up to and including the mass in running order thresholds referred to in Annex I to Regulation (EU) No 168/2013.
3.1. | L-category vehicles shall be equipped with an OBD system so designed, constructed and installed in a vehicle as to enable it to identify types of deterioration or malfunction over the entire life of the vehicle. In achieving this objective, the approval authority shall accept that vehicles which have travelled distances in excess of the Type V durability distance in Section (A) of Annex VII to Regulation (EU) No 168/2013 may show some deterioration in OBD system performance such that the OBD emission thresholds given in Section (B) of Annex VI to Regulation (EU) No 168/2013 may be exceeded before the OBD system signals a failure to the driver of the vehicle. 3.1.1. Access to the OBD system required for the inspection, diagnosis, servicing or repair of the vehicle shall be unrestricted and standardised. All OBD-relevant fault codes shall be consistent with point 3.11 of Appendix 1 to this Annex. 3.1.2. At the manufacturer’s discretion, to aid technicians in the efficient repair of L-category vehicles, the OBD system may be extended to monitor and report on any other on-board system. Extended diagnostic systems shall not be considered as falling under the scope of type-approval requirements. 3.1.1. | Access to the OBD system required for the inspection, diagnosis, servicing or repair of the vehicle shall be unrestricted and standardised. All OBD-relevant fault codes shall be consistent with point 3.11 of Appendix 1 to this Annex. 3.1.2. | At the manufacturer’s discretion, to aid technicians in the efficient repair of L-category vehicles, the OBD system may be extended to monitor and report on any other on-board system. Extended diagnostic systems shall not be considered as falling under the scope of type-approval requirements. 3.2. | The OBD system shall be so designed, constructed and installed in a vehicle as to enable it to comply with the requirements of this Annex during conditions of normal use. 3.2.1. Temporary disablement of the OBD system 3.2.1.1. A manufacturer may disable the OBD system if its ability to monitor is affected by low fuel levels or below the minimum state of charge of the propulsion or electric system batteries (maximum discharge of capacity). Disablement shall not occur when the fuel tank level is above 20 per cent of the nominal capacity of the fuel tank. 3.2.1.2. A manufacturer may disable the OBD system at ambient engine starting temperatures below 266.2 K (– 7 °C) or at elevations over 2 500 metres above sea level, provided it submits data and/or an engineering evaluation which adequately demonstrate that monitoring would be unreliable in such conditions. It may also request disablement of the OBD system at other ambient engine starting temperatures if it demonstrates to the authority with data and/or an engineering evaluation that misdiagnosis would occur under such conditions. It is not necessary to illuminate the malfunction indicator (MI) if the OBD thresholds are exceeded during regeneration, provided no defect is present. 3.2.1.3. For vehicles designed to accommodate the installation of power take-off units, disablement of affected monitoring systems is permitted provided disablement occurs only when the power take-off unit is active. In addition to the provisions of this section, the manufacturer may temporarily disable the OBD system in the following conditions: (a) For flex fuel or mono/bi fuel gas vehicles for one minute after refuelling to allow for the recognition of fuel quality and composition by the powertrain control unit(s) (PCU); (b) For bi fuel vehicles for five seconds after fuel switching to allow for engine parameters to be readjusted; (c) The manufacturer may deviate from these time limits if it can be demonstrated that stabilisation of the fuelling system after refuelling or fuel switching takes longer for justified technical reasons. In any case, the OBD system shall be re-enabled as soon as either the fuel quality or composition is recognised or the engine parameters are readjusted. 3.2.2. Engine misfire in vehicles equipped with positive-ignition engines. ▼M1 3.2.2.1. Manufacturers may adopt higher misfire percentage malfunction criteria than those declared to the authority, under specific engine speed and load conditions where it can be demonstrated to the authority that the detection of lower levels of misfire would be unreliable. In terms of OBD monitoring, it is that percentage of misfires out of a total number of firing events (as declared by the manufacturer) that would result in emissions exceeding the OBD thresholds set out in Section (B) of Annex VI to Regulation (EU) No 168/2013, or that percentage that could lead to an exhaust catalyst, or catalysts, overheating, causing irreversible damage. 3.2.2.2. When a manufacturer can demonstrate to the authority that the detection of higher levels of misfire percentages is still not feasible, or that misfire cannot be distinguished from other effects (e.g. rough roads, transmission shifts, after engine starting, etc.), the misfire monitoring system may be disabled when such conditions exist. ▼M2 3.2.3. Identification of deterioration or malfunctions may also be done outside a driving cycle (e.g. after engine shutdown). ▼B 3.2.1.1. | A manufacturer may disable the OBD system if its ability to monitor is affected by low fuel levels or below the minimum state of charge of the propulsion or electric system batteries (maximum discharge of capacity). Disablement shall not occur when the fuel tank level is above 20 per cent of the nominal capacity of the fuel tank. 3.2.1.2. | A manufacturer may disable the OBD system at ambient engine starting temperatures below 266.2 K (– 7 °C) or at elevations over 2 500 metres above sea level, provided it submits data and/or an engineering evaluation which adequately demonstrate that monitoring would be unreliable in such conditions. It may also request disablement of the OBD system at other ambient engine starting temperatures if it demonstrates to the authority with data and/or an engineering evaluation that misdiagnosis would occur under such conditions. It is not necessary to illuminate the malfunction indicator (MI) if the OBD thresholds are exceeded during regeneration, provided no defect is present. 3.2.1.3. | For vehicles designed to accommodate the installation of power take-off units, disablement of affected monitoring systems is permitted provided disablement occurs only when the power take-off unit is active. In addition to the provisions of this section, the manufacturer may temporarily disable the OBD system in the following conditions: (a) For flex fuel or mono/bi fuel gas vehicles for one minute after refuelling to allow for the recognition of fuel quality and composition by the powertrain control unit(s) (PCU); (b) For bi fuel vehicles for five seconds after fuel switching to allow for engine parameters to be readjusted; (c) The manufacturer may deviate from these time limits if it can be demonstrated that stabilisation of the fuelling system after refuelling or fuel switching takes longer for justified technical reasons. In any case, the OBD system shall be re-enabled as soon as either the fuel quality or composition is recognised or the engine parameters are readjusted. 3.2.2. | Engine misfire in vehicles equipped with positive-ignition engines. ▼M1 3.2.2.1. Manufacturers may adopt higher misfire percentage malfunction criteria than those declared to the authority, under specific engine speed and load conditions where it can be demonstrated to the authority that the detection of lower levels of misfire would be unreliable. In terms of OBD monitoring, it is that percentage of misfires out of a total number of firing events (as declared by the manufacturer) that would result in emissions exceeding the OBD thresholds set out in Section (B) of Annex VI to Regulation (EU) No 168/2013, or that percentage that could lead to an exhaust catalyst, or catalysts, overheating, causing irreversible damage. 3.2.2.2. When a manufacturer can demonstrate to the authority that the detection of higher levels of misfire percentages is still not feasible, or that misfire cannot be distinguished from other effects (e.g. rough roads, transmission shifts, after engine starting, etc.), the misfire monitoring system may be disabled when such conditions exist. 3.2.2.1. | Manufacturers may adopt higher misfire percentage malfunction criteria than those declared to the authority, under specific engine speed and load conditions where it can be demonstrated to the authority that the detection of lower levels of misfire would be unreliable. In terms of OBD monitoring, it is that percentage of misfires out of a total number of firing events (as declared by the manufacturer) that would result in emissions exceeding the OBD thresholds set out in Section (B) of Annex VI to Regulation (EU) No 168/2013, or that percentage that could lead to an exhaust catalyst, or catalysts, overheating, causing irreversible damage. 3.2.2.2. | When a manufacturer can demonstrate to the authority that the detection of higher levels of misfire percentages is still not feasible, or that misfire cannot be distinguished from other effects (e.g. rough roads, transmission shifts, after engine starting, etc.), the misfire monitoring system may be disabled when such conditions exist. 3.2.3. | Identification of deterioration or malfunctions may also be done outside a driving cycle (e.g. after engine shutdown). 3.3. | Description of tests 3.3.1. The OBD system shall indicate the failure of an emission-related component or system when that failure results in emissions exceeding the OBD emission threshold limits referred to in Annex VI(B) to Regulation (EU) No 168/2013. 3.3.2. Monitoring requirements for vehicles equipped with positive-ignition engines In satisfying the requirements of Article 21 of Regulation (EU) No 168/2013., the OBD system shall, at a minimum, monitor for: 3.3.2.1. The reduction in the efficiency of the catalytic converter with respect to emissions of hydrocarbons and nitrogen oxides. Manufacturers may monitor the front catalyst alone or in combination with the next catalyst(s) downstream. Each monitored catalyst or catalyst combination shall be considered to be malfunctioning if the emissions exceed the NMHC or NOx thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013. ▼M2 3.3.2.2. Engine misfireThe presence of engine misfire in the engine operating region bounded by the following lines: (a) low speed limit: A minimum speed of 2 500 min–1 or normal idle speed + 1 000 min–1, whichever is the lower (b) high speed limit: A maximum speed of 8 000 min–1 or 1 000 min–1 greater than the highest speed occurring during a type I test cycle or maximum design engine speed minus 500 min–1, whichever is lower (c) a line joining the following engine operating points: (i) a point on the low speed limit defined in (a) with the engine intake vacuum at 3,3 kPa lower than that at the positive torque line; (ii) a point on the high speed limit defined in (b) with the engine intake vacuum at 13,3 kPa lower than that at the positive torque. The engine operation region for misfire detection is reflected in Figure 10-1. Figure 10-1 Operating region for misfire detection Text of image minimum (max WMTC engine speed + 1 000 rpm, 8 000 rpm, max nominal engine speed – 500 rpm) 13,3 kPA 3,3 kPA minimum (nominal idle + 1 000 rpm, 2 500 rpm) Positive torque line ▼B 3.3.2.3. Oxygen sensor deteriorationThis section shall mean that the deterioration of all oxygen sensors fitted and used for monitoring malfunctions of the catalytic converter in accordance with the requirements of this Annex shall be monitored. 3.3.2.4. The electronic evaporative emission purge control shall, at a minimum, be monitored for circuit continuity. 3.3.2.5. For direct injection positive ignition engines, any malfunction that could lead to emissions exceeding the particulate mass (PM) OBD emission thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013 shall be monitored in accordance with the requirements of this Annex for compression ignition engines. 3.3.3. Monitoring requirements for vehicles equipped with compression ignition engines. In satisfying the requirements of Article 21 of Regulation (EU) No 168/2013, the OBD system shall monitor: 3.3.3.1. Reduction in the efficiency of the catalytic converter, where fitted; 3.3.3.2. The functionality and integrity of the particulate trap, where fitted. 3.3.3.3. The fuel-injection system electronic fuel quantity and timing actuator(s) is/are monitored for circuit continuity and total functional failure. 3.3.3.4. Malfunctions and the reduction in efficiency of the EGR system, shall be monitored. 3.3.3.5. Malfunctions and the reduction in efficiency of a NOx after-treatment system using a reagent and the reagent dosing subsystem shall be monitored. 3.3.3.6. Malfunctions and the reduction in efficiency of NOx after-treatment not using a reagent shall be monitored. 3.3.4. If active on the selected fuel, other emission control system components or systems, or emission-related powertrain components or systems, which are connected to a computer shall be monitored, the failure of which may result in tailpipe emissions exceeding the OBD emission thresholds given in Section B of Annex VI to Regulation (EU) No 168/2013. 3.3.5. Unless otherwise monitored, any other electronic powertrain component connected to a computer relevant for environmental performance and/or functional safety, including any relevant sensors to enable monitoring functions to be carried out, shall be monitored for electric/electronic circuit failures. In particular these electronic components shall be continuously monitored for any electric circuit continuity failure, shorted electric circuits, electric range/performance and stuck signal of the emissions control system. 3.3.6. Unless otherwise monitored, any other powertrain component connected to a computer relevant for the environmental performance and/or functional safety, triggering any programmed ‘limp-home’ operating mode which significantly reduces engine torque, e.g. to safeguard powertrain components. Without prejudice to the list Ap2-1 the relevant diagnostic trouble code shall be stored. 3.3.7. Manufacturers may demonstrate to the approval authority that certain components or systems need not be monitored if, in the event of their total failure or removal, emissions do not exceed the emission limits given in Section B of Annex VI to Regulation (EU) No 168/2013. 3.3.1. | The OBD system shall indicate the failure of an emission-related component or system when that failure results in emissions exceeding the OBD emission threshold limits referred to in Annex VI(B) to Regulation (EU) No 168/2013. 3.3.2. | Monitoring requirements for vehicles equipped with positive-ignition engines In satisfying the requirements of Article 21 of Regulation (EU) No 168/2013., the OBD system shall, at a minimum, monitor for: 3.3.2.1. The reduction in the efficiency of the catalytic converter with respect to emissions of hydrocarbons and nitrogen oxides. Manufacturers may monitor the front catalyst alone or in combination with the next catalyst(s) downstream. Each monitored catalyst or catalyst combination shall be considered to be malfunctioning if the emissions exceed the NMHC or NOx thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013. ▼M2 3.3.2.2. Engine misfireThe presence of engine misfire in the engine operating region bounded by the following lines: (a) low speed limit: A minimum speed of 2 500 min–1 or normal idle speed + 1 000 min–1, whichever is the lower (b) high speed limit: A maximum speed of 8 000 min–1 or 1 000 min–1 greater than the highest speed occurring during a type I test cycle or maximum design engine speed minus 500 min–1, whichever is lower (c) a line joining the following engine operating points: (i) a point on the low speed limit defined in (a) with the engine intake vacuum at 3,3 kPa lower than that at the positive torque line; (ii) a point on the high speed limit defined in (b) with the engine intake vacuum at 13,3 kPa lower than that at the positive torque. The engine operation region for misfire detection is reflected in Figure 10-1. Figure 10-1 Operating region for misfire detection Text of image minimum (max WMTC engine speed + 1 000 rpm, 8 000 rpm, max nominal engine speed – 500 rpm) 13,3 kPA 3,3 kPA minimum (nominal idle + 1 000 rpm, 2 500 rpm) Positive torque line ▼B 3.3.2.3. Oxygen sensor deteriorationThis section shall mean that the deterioration of all oxygen sensors fitted and used for monitoring malfunctions of the catalytic converter in accordance with the requirements of this Annex shall be monitored. 3.3.2.4. The electronic evaporative emission purge control shall, at a minimum, be monitored for circuit continuity. 3.3.2.5. For direct injection positive ignition engines, any malfunction that could lead to emissions exceeding the particulate mass (PM) OBD emission thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013 shall be monitored in accordance with the requirements of this Annex for compression ignition engines. 3.3.2.1. | The reduction in the efficiency of the catalytic converter with respect to emissions of hydrocarbons and nitrogen oxides. Manufacturers may monitor the front catalyst alone or in combination with the next catalyst(s) downstream. Each monitored catalyst or catalyst combination shall be considered to be malfunctioning if the emissions exceed the NMHC or NOx thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013. 3.3.2.2. | Engine misfireThe presence of engine misfire in the engine operating region bounded by the following lines: (a) low speed limit: A minimum speed of 2 500 min–1 or normal idle speed + 1 000 min–1, whichever is the lower (b) high speed limit: A maximum speed of 8 000 min–1 or 1 000 min–1 greater than the highest speed occurring during a type I test cycle or maximum design engine speed minus 500 min–1, whichever is lower (c) a line joining the following engine operating points: (i) a point on the low speed limit defined in (a) with the engine intake vacuum at 3,3 kPa lower than that at the positive torque line; (ii) a point on the high speed limit defined in (b) with the engine intake vacuum at 13,3 kPa lower than that at the positive torque. The engine operation region for misfire detection is reflected in Figure 10-1. Figure 10-1 Operating region for misfire detection Text of image minimum (max WMTC engine speed + 1 000 rpm, 8 000 rpm, max nominal engine speed – 500 rpm) 13,3 kPA 3,3 kPA minimum (nominal idle + 1 000 rpm, 2 500 rpm) Positive torque line 3.3.2.3. | Oxygen sensor deteriorationThis section shall mean that the deterioration of all oxygen sensors fitted and used for monitoring malfunctions of the catalytic converter in accordance with the requirements of this Annex shall be monitored. 3.3.2.4. | The electronic evaporative emission purge control shall, at a minimum, be monitored for circuit continuity. 3.3.2.5. | For direct injection positive ignition engines, any malfunction that could lead to emissions exceeding the particulate mass (PM) OBD emission thresholds provided for in Section B of Annex VI to Regulation (EU) No 168/2013 shall be monitored in accordance with the requirements of this Annex for compression ignition engines. 3.3.3. | Monitoring requirements for vehicles equipped with compression ignition engines. In satisfying the requirements of Article 21 of Regulation (EU) No 168/2013, the OBD system shall monitor: 3.3.3.1. Reduction in the efficiency of the catalytic converter, where fitted; 3.3.3.2. The functionality and integrity of the particulate trap, where fitted. 3.3.3.3. The fuel-injection system electronic fuel quantity and timing actuator(s) is/are monitored for circuit continuity and total functional failure. 3.3.3.4. Malfunctions and the reduction in efficiency of the EGR system, shall be monitored. 3.3.3.5. Malfunctions and the reduction in efficiency of a NOx after-treatment system using a reagent and the reagent dosing subsystem shall be monitored. 3.3.3.6. Malfunctions and the reduction in efficiency of NOx after-treatment not using a reagent shall be monitored. 3.3.4. | If active on the selected fuel, other emission control system components or systems, or emission-related powertrain components or systems, which are connected to a computer shall be monitored, the failure of which may result in tailpipe emissions exceeding the OBD emission thresholds given in Section B of Annex VI to Regulation (EU) No 168/2013. 3.3.5. | Unless otherwise monitored, any other electronic powertrain component connected to a computer relevant for environmental performance and/or functional safety, including any relevant sensors to enable monitoring functions to be carried out, shall be monitored for electric/electronic circuit failures. In particular these electronic components shall be continuously monitored for any electric circuit continuity failure, shorted electric circuits, electric range/performance and stuck signal of the emissions control system. 3.3.6. | Unless otherwise monitored, any other powertrain component connected to a computer relevant for the environmental performance and/or functional safety, triggering any programmed ‘limp-home’ operating mode which significantly reduces engine torque, e.g. to safeguard powertrain components. Without prejudice to the list Ap2-1 the relevant diagnostic trouble code shall be stored. 3.3.7. | Manufacturers may demonstrate to the approval authority that certain components or systems need not be monitored if, in the event of their total failure or removal, emissions do not exceed the emission limits given in Section B of Annex VI to Regulation (EU) No 168/2013. 3.4. | A sequence of diagnostic checks shall be initiated at each engine start and completed at least once provided that the correct test conditions are met. The test conditions shall be selected in such a way that they all occur in the course of normal driving as represented by the Type I test. If the failure cannot be reliably detected under the Type I test conditions, the manufacturer may propose supplemental test conditions that do allow robust detection of the failure to be agreed with the technical service to the satisfaction of the approval authority. 3.5. | Activation of malfunction indicator (MI) 3.5.1. The OBD system shall incorporate a malfunction indicator readily perceivable to the vehicle operator. The MI shall not be used for any purposes other than to indicate emergency start-up or limp-home routines to the driver. The MI shall be visible in all reasonable lighting conditions. When activated, it shall display a symbol in conformity with ISO 2575:2010, symbol F.01. A vehicle shall not be equipped with more than one general purpose MI for emission-related problems or powertrain faults leading to significantly reduced torque. Separate specific purpose tell-tales (e. g. brake system, fasten seat belt, oil pressure, etc.) are permitted. The use of red colour for an MI is prohibited. 3.5.2. For strategies requiring more than two preconditioning cycles for MI activation, the manufacturer shall provide data and/or an engineering evaluation which adequately demonstrate that the monitoring system is equally effective and timely in detecting component deterioration. Strategies requiring on average more than ten driving cycles for MI activation are not accepted. The MI shall also activate whenever the powertrain control enters a permanent default mode of operation leading to a significant torque reduction or if the OBD emission thresholds in Section (B) of Annex VI to Regulation (EU) No 168/2013 are exceeded or if the OBD system is unable to fulfil the basic monitoring requirements laid down in points 3.3.2 or 3.3.3. 3.5.3. The MI shall operate in a distinct warning mode, e.g. a flashing light, during any period in which engine misfire occurs at a level likely to cause catalyst damage, as specified by the manufacturer. 3.5.4. The MI shall also activate when the vehicle’s ignition is in the ‘key on’ position before engine starting or cranking and deactivate if no malfunction has been detected. For vehicles not equipped with a battery, the MI shall illuminate immediately after engine starting and shall subsequently be deactivated after 5 seconds, if no malfunction has previously been detected. 3.5.1. | The OBD system shall incorporate a malfunction indicator readily perceivable to the vehicle operator. The MI shall not be used for any purposes other than to indicate emergency start-up or limp-home routines to the driver. The MI shall be visible in all reasonable lighting conditions. When activated, it shall display a symbol in conformity with ISO 2575:2010, symbol F.01. A vehicle shall not be equipped with more than one general purpose MI for emission-related problems or powertrain faults leading to significantly reduced torque. Separate specific purpose tell-tales (e. g. brake system, fasten seat belt, oil pressure, etc.) are permitted. The use of red colour for an MI is prohibited. 3.5.2. | For strategies requiring more than two preconditioning cycles for MI activation, the manufacturer shall provide data and/or an engineering evaluation which adequately demonstrate that the monitoring system is equally effective and timely in detecting component deterioration. Strategies requiring on average more than ten driving cycles for MI activation are not accepted. The MI shall also activate whenever the powertrain control enters a permanent default mode of operation leading to a significant torque reduction or if the OBD emission thresholds in Section (B) of Annex VI to Regulation (EU) No 168/2013 are exceeded or if the OBD system is unable to fulfil the basic monitoring requirements laid down in points 3.3.2 or 3.3.3. 3.5.3. | The MI shall operate in a distinct warning mode, e.g. a flashing light, during any period in which engine misfire occurs at a level likely to cause catalyst damage, as specified by the manufacturer. 3.5.4. | The MI shall also activate when the vehicle’s ignition is in the ‘key on’ position before engine starting or cranking and deactivate if no malfunction has been detected. For vehicles not equipped with a battery, the MI shall illuminate immediately after engine starting and shall subsequently be deactivated after 5 seconds, if no malfunction has previously been detected. 3.6. | The OBD system shall record fault code(s) indicating the status of the emission control system or of the functional safety system leading to an operation mode with significantly reduced torque in comparison to normal operation mode. Separate status codes shall be used to identify correctly functioning emission control systems, functional safety systems and those emission control systems which need further vehicle operation to be fully evaluated. If the MI is activated due to deterioration or malfunction or permanent emission default modes of operation, a fault code shall be stored that identifies the type of malfunction. ►M1 A fault code shall also be stored in the cases referred to in points 3.3.5. and 3.3.6. ◄ 3.6.1. ►M1 The distance travelled by the vehicle while the MI is activated shall be available at any moment through the serial port on the standardised diagnostic connector. By means of derogation for vehicles equipped with a mechanically operating odometer that does not allow input to the electronic control unit including such vehicles equipped with a CVT that does not allow for an accurate input to the electronic control unit, ‘distance travelled’ may be replaced with ‘engine operation time’ and shall be made available at any moment through the serial port on the standardised diagnostic connector. ◄ 3.6.2. In the case of vehicles equipped with positive-ignition engines, misfiring cylinders need not be uniquely identified if a distinct single or multiple cylinder misfire fault code is stored. 3.6.3. The MI may be activated at levels of emissions below the OBD emission thresholds set out in Section B of Annex VI to Regulation (EU) No 168/2013. 3.6.3. The MI may be activated if a default mode is active without significant reduction of propulsion torque. 3.6.1. | ►M1 The distance travelled by the vehicle while the MI is activated shall be available at any moment through the serial port on the standardised diagnostic connector. By means of derogation for vehicles equipped with a mechanically operating odometer that does not allow input to the electronic control unit including such vehicles equipped with a CVT that does not allow for an accurate input to the electronic control unit, ‘distance travelled’ may be replaced with ‘engine operation time’ and shall be made available at any moment through the serial port on the standardised diagnostic connector. ◄ 3.6.2. | In the case of vehicles equipped with positive-ignition engines, misfiring cylinders need not be uniquely identified if a distinct single or multiple cylinder misfire fault code is stored. 3.6.3. | The MI may be activated at levels of emissions below the OBD emission thresholds set out in Section B of Annex VI to Regulation (EU) No 168/2013. 3.6.3. | The MI may be activated if a default mode is active without significant reduction of propulsion torque. 3.7. | Extinguishing the MI 3.7.1. If misfire at levels likely to cause catalyst damage (as specified by the manufacturer) is no longer taking place, or if the engine is operated after changes to speed and load conditions where the level of misfire will not cause catalyst damage, the MI may be switched back to the previous state of activation during the first driving cycle on which the misfire level was detected and to the normal activated mode on subsequent driving cycles. If the MI is switched back to the previous state of activation, the corresponding fault codes and stored freeze-frame conditions may be erased. 3.7.2. For all other malfunctions, the MI may be deactivated after three subsequent sequential driving cycles during which the monitoring system responsible for activating the MI ceases to detect the malfunction and if no other malfunction has been identified that would independently activate the MI. 3.7.1. | If misfire at levels likely to cause catalyst damage (as specified by the manufacturer) is no longer taking place, or if the engine is operated after changes to speed and load conditions where the level of misfire will not cause catalyst damage, the MI may be switched back to the previous state of activation during the first driving cycle on which the misfire level was detected and to the normal activated mode on subsequent driving cycles. If the MI is switched back to the previous state of activation, the corresponding fault codes and stored freeze-frame conditions may be erased. 3.7.2. | For all other malfunctions, the MI may be deactivated after three subsequent sequential driving cycles during which the monitoring system responsible for activating the MI ceases to detect the malfunction and if no other malfunction has been identified that would independently activate the MI. 3.8. | Erasing a fault code 3.8.1. The OBD system may erase a fault code and the distance travelled and freeze-frame information if the same fault is not reregistered in at least 40 engine warm-up cycles. 3.8.2. Stored faults shall not be erased by disconnection of the on-board computer from the vehicle power supply or by disconnection or failure of the vehicle battery or batteries. 3.8.1. | The OBD system may erase a fault code and the distance travelled and freeze-frame information if the same fault is not reregistered in at least 40 engine warm-up cycles. 3.8.2. | Stored faults shall not be erased by disconnection of the on-board computer from the vehicle power supply or by disconnection or failure of the vehicle battery or batteries. 3.9. | Bi-fuelled gas vehiclesIn general, all the OBD requirements applying to a mono-fuelled vehicle apply to bi-fuelled gas vehicles for each of the fuel types (petrol and (NG/biomethane)/LPG)). To this end, one of the following two alternatives in points 3.8.1 or 3.8.2 or any combination thereof shall be used. 3.9.1. One OBD system for both fuel types 3.9.1.1. The following procedures shall be executed for each diagnostic in a single OBD system for operation on petrol and on (NG/biomethane)/LPG, either independent of the fuel currently in use or fuel-type specific: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). For components or systems to be monitored, either separate diagnostics for each fuel type can be used or a common diagnostic. 3.9.1.2. The OBD system can reside in either one or more computers. 3.9.2. Two separate OBD systems, one for each fuel type. 3.9.2.1. The following procedures shall be executed independently of each other when the vehicle is operated on petrol or on (NG/biomethane)/LPG: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). 3.9.2.2. The separate OBD systems can reside in either one or more computers. 3.9.3. Specific requirements regarding the transmission of diagnostic signals from bi-fuelled gas vehicles. 3.9.3.1. On a request from a diagnostic scan tool, the diagnostic signals shall be transmitted on one or more source addresses. The use of source addresses is set out in ISO 15031-5:2011. 3.9.3.2. Identification of fuel specific information can be realised: (a) By use of source addresses; and/or (b) By use of a fuel select switch; and/or (c) By use of fuel specific fault codes. 3.9.4. Regarding the status code (described in point 3.6), one of the following two alternatives has to be used if one or more of the diagnostics reporting readiness is fuel-type specific: (a) The status code is fuel specific, i.e. use of two status codes, one for each fuel type; (b) The status code shall indicate fully evaluated control systems for both fuel types (petrol and (NG/biomethane)/LPG)) when the control systems are fully evaluated for one of the fuel types. If none of the diagnostics reporting readiness is fuel-type specific, only one status code has to be supported. 3.9.1. | One OBD system for both fuel types 3.9.1.1. The following procedures shall be executed for each diagnostic in a single OBD system for operation on petrol and on (NG/biomethane)/LPG, either independent of the fuel currently in use or fuel-type specific: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). For components or systems to be monitored, either separate diagnostics for each fuel type can be used or a common diagnostic. 3.9.1.2. The OBD system can reside in either one or more computers. 3.9.1.1. | The following procedures shall be executed for each diagnostic in a single OBD system for operation on petrol and on (NG/biomethane)/LPG, either independent of the fuel currently in use or fuel-type specific: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). For components or systems to be monitored, either separate diagnostics for each fuel type can be used or a common diagnostic. 3.9.1.2. | The OBD system can reside in either one or more computers. 3.9.2. | Two separate OBD systems, one for each fuel type. 3.9.2.1. The following procedures shall be executed independently of each other when the vehicle is operated on petrol or on (NG/biomethane)/LPG: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). 3.9.2.2. The separate OBD systems can reside in either one or more computers. 3.9.2.1. | The following procedures shall be executed independently of each other when the vehicle is operated on petrol or on (NG/biomethane)/LPG: (a) Activation of malfunction indicator (MI) (see point 3.5); (b) Fault code storage (see point 3.6); (c) Extinguishing the MI (see point 3.7); (d) Erasing a fault code (see point 3.8). 3.9.2.2. | The separate OBD systems can reside in either one or more computers. 3.9.3. | Specific requirements regarding the transmission of diagnostic signals from bi-fuelled gas vehicles. 3.9.3.1. On a request from a diagnostic scan tool, the diagnostic signals shall be transmitted on one or more source addresses. The use of source addresses is set out in ISO 15031-5:2011. 3.9.3.2. Identification of fuel specific information can be realised: (a) By use of source addresses; and/or (b) By use of a fuel select switch; and/or (c) By use of fuel specific fault codes. 3.9.3.1. | On a request from a diagnostic scan tool, the diagnostic signals shall be transmitted on one or more source addresses. The use of source addresses is set out in ISO 15031-5:2011. 3.9.3.2. | Identification of fuel specific information can be realised: (a) By use of source addresses; and/or (b) By use of a fuel select switch; and/or (c) By use of fuel specific fault codes. 3.9.4. | Regarding the status code (described in point 3.6), one of the following two alternatives has to be used if one or more of the diagnostics reporting readiness is fuel-type specific: (a) The status code is fuel specific, i.e. use of two status codes, one for each fuel type; (b) The status code shall indicate fully evaluated control systems for both fuel types (petrol and (NG/biomethane)/LPG)) when the control systems are fully evaluated for one of the fuel types. If none of the diagnostics reporting readiness is fuel-type specific, only one status code has to be supported. 3.10. | Additional provisions for vehicles employing engine shut-off strategies. 3.10.1. Driving cycle 3.10.1.1. Autonomous engine restarts commanded by the engine control system following an engine stall may be considered a new driving cycle or a continuation of the existing driving cycle. 3.10.1.1. | Autonomous engine restarts commanded by the engine control system following an engine stall may be considered a new driving cycle or a continuation of the existing driving cycle.
1.
Subject matterchanged
The following minimum monitoring requirements shall apply for OBD systems complying with the requirements of stages I and II ►M2 ————— ◄ regarding electric circuit diagnostics.
1.
General requirementschanged
1.1. | Technical services shall demonstrate appropriate skills, specific technical knowledge and proven experience in the specific fields of competence covered by Chapter XVI of Regulation (EU) No 168/2013 and Appendices 1 and 2 to Annex V to Directive 2007/46/EC. 1.2. | Standards with which technical services of the different categories set out in Article 63 of Regulation (EU) No 168/2013 shall comply 1.2.1. The different categories of technical services shall comply with the standards set out in Appendix 1 to Annex V to Directive 2007/46/EC 1.2.2. The reference to Article 41 of Directive 2007/46/EC in that Appendix shall be construed as a reference to Article 63 of Regulation (EU) No 168/2013. 1.2.3. The reference to Annex IV to Directive 2007/46/EC in that Appendix shall be construed as a reference to Annex II to Regulation (EU) No 168/2013. 1.3. | Procedure for the assessment of the technical services 1.3.1. The technical services are assessed in accordance with the procedure set out in Appendix 2 to Annex V to Directive 2007/46/EC. 1.3.2. References to Article 42 of Directive 2007/46/EC in Appendix 1 to Annex V to Directive 2007/46/EC shall be construed as references to Article 66 of Regulation (EU) No 168/2013. ( 1 ) OJ L 227, 28.8.2010, p. 1. ( 2 ) OJ L 89, 27.3.2013, p. 37. ( 3 ) OJ L 120, 13.5.2010, p. 29. ( 4 ) OJ L 254, 20.9.2012, p. 1. ( 5 ) OJ L 215, 14.8.2010, p. 27. ( 6 ) OJ L 72, 14.3.2008, p. 1. ( 7 ) OJ L 120, 7.5.2011, p. 1. ( 8 ) Directive 2007/46/EC of the European Parliament and of the Council of 5 September 2007 establishing a framework for the approval of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles (Framework Directive) (OJ L 263, 9.10.2007, p. 1). ( 9 ) Commission Implementing Regulation (EU) No 901/2014 of 18 July 2014 implementing Regulation (EU) No 168/2013 of the European Parliament and of the Council with regard to the administrative requirements for the approval and market surveillance of two- or three-wheel vehicles and quadricycles (OJ L 249, 22.8.2014, p. 1).
1.1.added
‘Type of vehicle with regard to cybersecurity’ means a category of vehicles which do not differ in the following respects:
(a)added
the manufacturer’s designation of the vehicle type;
(b)added
essential aspects of the electric/electronic architecture and external interfaces with respect to cyber security.
1.2.added
Vehicles of categories L1e, L2e, L3e, L4e, L5e, L6e and L7e, except L1e vehicles designed to pedal referred to in Article 3, point (94)(b), of Regulation (EU) No 168/2013, shall meet all the relevant requirements of UN regulation No 155.
1.3.added
Points 1.1 and 1.2 shall apply as follows:
(a)added
to new vehicle types from 11 December 2027;
(b)added
to existing vehicle types from 11 June 2029.
(
1
)
OJ L 227, 28.8.2010, p. 1.
(
2
)
OJ L 89, 27.3.2013, p. 37.
(
3
)
OJ L 120, 13.5.2010, p. 29.
(
4
)
OJ L 254, 20.9.2012, p. 1.
(
5
)
OJ L 215, 14.8.2010, p. 27.
(
6
)
OJ L 72, 14.3.2008, p. 1.
(
7
)
OJ L 120, 7.5.2011, p. 1.
(
8
) Directive 2007/46/EC of the European Parliament and of the Council of 5 September 2007 establishing a framework for the approval of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles (Framework Directive) (OJ L 263, 9.10.2007, p. 1).
(
9
) Commission Implementing Regulation (EU) No 901/2014 of 18 July 2014 implementing Regulation (EU) No 168/2013 of the European Parliament and of the Council with regard to the administrative requirements for the approval and market surveillance of two- or three-wheel vehicles and quadricycles (OJ L 249, 22.8.2014, p. 1).