Compare versions of UN R110
I. Specific components of motor vehicles using compressed natural gas (CNG) and/or liquefied natural gas (LNG) in their propulsion system II. Vehicles with regard to the installation of specific components of an approved type for the use of compressed natural gas (CNG) and/or liquefied natural gas (LNG) in their propulsion system
01 series of amendments → latestSupplement 1 to the 01 series → latest02 series of amendments → latest03 series of amendments → latest04 series of amendments → latest
1.1.changed
Part I Specific components for vehicles of category M and N1 N 1 using compressed natural gas (CNG) and/or liquefied natural gas (LNG) in their propulsion system;
2.changed
The following standards contain provisions that, through reference in this text, constitute provisions of this Regulation. ASTM Standards2 ASTM B117-90 Test method of Salt Spray (Fog) Testing ASTM B154-92 Mercurous Nitrate Test for Copper and Copper Alloys ASTM D522-92 Mandrel Bend Test of attached Organic Coatings ASTM D1308-87 Effect of Household Chemicals on Clear and Pigmented Organic Finishes ASTM D2344-84 Test Method for Apparent interlaminar Shear Strength of Parallel Fibre Composites by Short Beam Method ASTM D2794-92 Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact) ASTM D3170-87 Chipping Resistance of Coatings ASTM D3418-83 Test Method for Transition Temperatures Polymers by Thermal Analysis ASTM E647-93 Standard Test, Method for Measurement of Fatigue Crack Growth Rates ASTM E813-89 Test Method for JIC, a Measure of Fracture Toughness ASTM G53-93 Standard Practice for Operating Light and Water – Exposure Apparatus (Fluorescent UV- Condensation Type) for Exposure of non- metallic materials As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.3, para. 2. – www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html American Society for Testing and Materials. BSI Standards3 BS 5045 Part 1 (1982) Transportable Gas Containers – Specification for Seamless Steel Gas Containers Above 0.5 litre Water Capacity 1 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.3, para. 2. – www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html 2 American Society for Testing and Materials. 3 British Standards Institution. BS 7448-91 Fracture Mechanics Toughness Tests Part I – Method for Determination of KIC, Critical COD and Critical J Values of BS PD 6493-1991. Guidance an Methods for Assessing the A Acceptability of Flaws in Fusion Welded Structures; Metallic Materials EN Standards4 EN 13322-2 2003 Transportable gas cylinders – Refillable welded steel gas cylinders – Design and construction – Part 2: Stainless steel EN ISO 5817 2003 Arc-welded joints in steel; guidance on quality levels for imperfections EN1251-2 2000 Cryogenic vessels. Vacuum insulated vessels of not more than 1,000 litres volume EN 895:1995 Destructive tests on welds in metallic materials. Transverse tensile test EN 910:1996 Destructive test methods on welds in metallic materials. Bend tests EN 1435:1997 Non-destructive examination of welds. Radiographic examination of welded joints EN 6892-1:2009 Metallic materials. Tensile test EN 10045-1:1990 Charpy impact test on metallic materials. Test method (V- and U-notches) ISO Standards5 ISO 37 Rubber, vulcanized or thermoplastic – Determination of tensile stress-strain properties. ISO 148-1983 Steel – Charpy Impact Test (v-notch) ISO 188 Rubber, volcanized or thermoplastic – Accelerated ageing and heat resistance tests ISO 306-1987 Plastics - Thermoplastic Materials – Determination of Vicat Softening Temperature ISO 527 Pt 1-93 Plastics - Determination of Tensile Properties – Part I: General principles ISO 642-79 Steel-Hardenability Test by End Quenching (Jominy Test) British Standards Institution. European Norm. International Organization for Standardization. ISO 12991 Liquefied natural gas (LNG) – transportable tanks for use on-board vehicles ISO1307 Rubber and plastics hoses – Hose sizes, minimum and maximum inside diameters, and tolerances on cut-to-length hoses ISO 1402 Rubber and plastics hoses and hose assemblies – Hydrostatic testing ISO 1431 Rubber, vulcanized or thermoplastic – Resistance to ozone cracking 4 European Norm. 5 International Organization for Standardization. ISO 1436 Rubber hoses and hose assemblies – Wire-braid- reinforced hydraulic types for oil-based or water- based fluids – Specification ISO 1817 Rubber, vulcanized or thermoplastic – Determination of the effect of liquids ISO 2808-91 Paints and Varnishes – Determination of film Thickness ISO 3628-78 Glass Reinforced Materials – Determination of Tensile Properties ISO 4080 Rubber and plastics hoses and hose assemblies – Determination of permeability to gas ISO 4624-78 Plastics and Varnishes – Pull-off Test for adhesion ISO 4672 Rubber and plastics – Sub-ambient temperature flexibility tests ISO 6982-84 Metallic Materials – Tensile Testing ISO 6506-1981 Metallic Materials – Hardness test – Brinell Test ISO 6508-1986 Metallic Materials – Hardness Tests – Rockwell Test (Scales, ABCDEFGHK) ISO 7225 Precautionary Labels for Gas Cylinders ISO/DIS 7866-1992 Refillable Transportable Seamless Aluminium Alloy Cylinders for Worldwide Usage Design, Manufacture and Acceptance ISO 9001:1994 Quality Assurance in Design/Development. Production, Installation and Servicing ISO 9002:1994 Quality Assurance in Production and Installation ISO/DIS 12737 Metallic Materials – Determination of the Plane- Strain Fracture Toughness ISO12991 Liquefied natural gas (LNG) – transportable tanks for use on board of vehicles ISO14469-1:2004 Road Vehicles: compressed natural gas CNG refuelling connector: Part I: 20 MPa (200 bar) connector ISO14469-2:2007 Road Vehicles: compressed natural gas CNG refuelling connector: Part II: 20 MPa (200 bar) connector ISO15500 Road vehicles – Compressed natural gas (CNG) fuel system components ISO 21028-1:2004 Cryogenic vessels – Toughness requirements for materials at cryogenic temperature – Part I: Temperatures below -80 °C ISO 21029-1:2004 Cryogenic vessels – Transportable vacuum insulated vessels of not more than 1,000 litres volume – Part I: Design, fabrication, inspection and tests ISO/IEC Guide 25-1990 General requirements for the Technical Competence of Testing Laboratories ISO/IEC Guide 48-1986 Guidelines for Third Party Assessment and Registration of Supplies Quality System ISO/DIS 9809 Transportable Seamless Steel Gas Cylinders Design, Construction and Testing – Part I: Quenched and Tempered Steel Cylinders with Tensile Strength < 1,100 MPa ISO 11439 Gas cylinders — High pressure cylinders for the on-board storage of natural gas as a fuel for automotive vehicles NACE Standard6 NACE TM0177-90 Laboratory Testing of Metals for Resistance to Sulphide Stress Cracking in H2S Environments ECE UN Regulations7 UN Regulation No. 10 Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility USA Federal Regulations8 49 CFR 393.67 Liquid fuel tanks SAE Standards Standards9 SAE J2343-2008 Recommended Practice for LNG Medium and Heavy-Duty Powered Vehicles National Association of Corrosion Engineers. United Nations Economic Commission for Europe; Regulations. United States of America Federal Regulations Society of Automotive Engineers
3.changed
Class 0 High pressure parts including tubes and fittings containing CNG at a pressure higher than 3 MPa and up to 26 MPa. Class 1 Medium pressure parts including tubes and fittings containing CNG at a pressure higher than 450 kPa and up to 3,000 kPa (3 MPa). Class 2 Low pressure parts including tubes and fittings containing CNG at a pressure higher than 20 kPa and up to 450 kPa. Class 3 Medium pressure parts as safety valves or protected by safety valve including tubes and fittings containing CNG at a pressure higher than 450 kPa and up to 3,000 kPa (3 MPa). Class 4 Parts in contact with gas subject to the pressure lower than 20 kPa. 6 National Association of Corrosion Engineers. 7 United Nations Economic Commission for Europe; UN Regulations. 8 United States of America Federal Regulations 9 Society of Automotive Engineers Class 5 Parts in contact with temperature range extending below -40 °C. A Class 6 High pressure parts including tubes and fittings containing CNG, excluding CNG containers, at a pressure higher than 26 MPa.A component can consist of several parts, each part classified in its own class with regard to maximum working pressure and function. CNG and/or LNG components for use in vehicles shall be classified with regard to the working pressure, temperature and function, according to
Figure 1changed
Flow scheme for CNG and/or LNG components classification START In contact NO with No gas YES Yes Yes Temperature YES Class 5 < ˂ -40 °C NO P0 > 3,000 No Yes No po>3,000 kPa YES P0 < 26,000 NO po ˂26,000 kPa YES Storage cylinder No Class 6 Yes No Class 0 NO 450 < p0 < 3,000 YES Yes No Safety NO valve Class 1 450˂po˂3,000 kPa valve NO YES No Yes Class 3 20 < p0 < YES Yes 20˂po˂450 kPa Class 2 450 kPa NO No Class 4 Not subject to this Regulation Tests applicable to specific classes of components (excluding CNG cylinders and LNG tank) Test Class 0 Class 1 Class 2 Class 3 Class 4 Class 5 Class 6 Annex Overpressure or strength X X X X O X X 5A External leakage X X X X O X X 5B Internal leakage A A A A O A A 5C Durability tests A A A A O A A 5L CNG/LNG compatibility A A A A A A A 5D Corrosion resistance X X X X X A X 5E Resistance to dry heat A A A A A A A 5F Ozone ageing A A A A A A A 5G Burst/destructive tests X O O O O A X 5M Temperature cycle A A A A O A A 5H Pressure cycle X O O O O A X 5I Vibration resistance A A A A O A A 5N Operating temperatures X X X X X X X 5O LNG low temperature O O O O O X O 5P X = Applicable O = Not applicable A = As applicable
4.2.changed
"Service pressure" or "Operating pressure" means the settled pressure at a uniform gas temperature of 15 °C. C. Service pressure for LNG means the intended settled pressure of the tank in use –as declared by the manufacturer.
4.4.changed
"Working pressure" means the maximum pressure to which a component is designed to be subjected to and which is the basis for determining the strength of the component under consideration. For CNG cylinder, the settled pressure of 20 MPa at a uniform temperature of 15 °C. C. For LNG tank, the pressure of the LNG tank primary relief valve setting.
4.74.changed
"LNG filling receptacle" means device connected to a vehicle or storage system which receives the LNG fuelling nozzle and permits safe transfer of fuel. The receptacle consists as minimum from a receptacle body and from a check valve mounted inside the body. Part I Approval of specific components of motor vehicles using compressed natural gas (CNG) and/or liquefied natural gas (LNG) in their propulsion system
4.75.added
"Commanded stop phase" defines the period of time during which the
combustion engine is switched off automatically for fuel saving and is
allowed to start again automatically.
Part I
Approval of specific components of motor vehicles using
compressed natural gas (CNG) and/or liquefied natural gas
(LNG) in their propulsion system
6.1.1.added
In addition to provisions of paragraph 6.1., one of the following additional
marks shall be used for automatic cylinder valve which comply with
paragraph 2.2.4. of Annex 4A:
(a) "H1"
10 [n] stands for the sample size and shall be determined by the Type Approval Authority.
(b) "H2"
(c) "H3"
6.3.changed
Every container shall also bear a marking plate with the following data clearly legible and indelible: [n] stands for the sample size and shall be determined by the Type Approval Authority . (a) A serial number; (b) The capacity in litres; (c) The marking "CNG"; (d) Operating pressure/test pressure/working pressure [MPa]; (e) Mass (kg); (f) Year and month of approval (e.g. 96/01); (g) Approval mark according to paragraph 7.4.
6.4.changed
Every tank automatic valve and every pressure relief device fitted to the container shall also bear a marking plate with the following data clearly legible and indelible: (a) Serial number; (b) Gross capacity in litres; (c) The marking "LNG"; (d) Service pressure/Working "CNG"; (b) Working pressure [MPa]; (e) Mass (kg); (f) Manufacturer; (g) Year and month of approval (e.g. 96/01); (h) The marking "PUMP INSIDE, Pump Delivery Pressure *** MPa" if the LNG fuel pump is mounted on the tank; where the *** is the value of the pump delivery pressure; (i) Approval mark according to paragraph 7.4. below. [MPa].
6.5.added
Every tank shall also bear a marking plate with the following data clearly
legible and indelible:
(a) Serial number;
(b) Gross capacity in litres;
(c) The marking "LNG";
(d) Service pressure/Working pressure [MPa];
(e) Mass (kg);
(f) Manufacturer;
(g) Year and month of approval (e.g. 96/01);
(h) The marking "PUMP INSIDE, Pump Delivery Pressure *** MPa" if
the LNG fuel pump is mounted on the tank; where the *** is the value
of the pump delivery pressure;
(i) Approval mark according to paragraph 7.4. below.
6.6.added
Every one of the following components shall also bear a clearly legible and indelible
marking of the data listed below (a) and (b): pressure relief valve (primary); pressure
relief valve (secondary); manual fuel shut off valve; manual vapour shut off valve;
LNG check valve; and LNG valves (manual or automatic) fitted to the tank.
(a) The marking "LNG";
(b) Working pressure [MPa].
7.1.changed
If the CNG component samples submitted for approval meet the requirements of paragraphs 8.1. to 8.11. of this Regulation, approval of the type of component shall be granted. If the LNG components samples submitted for approval meet the requirements of paragraphs 8.12. to 8.21. 8.22. of this Regulation, approval of the type of component shall be granted.
7.2.changed
An approval number shall be assigned to each type of component or multifunctional component approved. Its first two digits (at present 01 02 corresponding to the 01 02 series of amendments) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party shall not assign the same alphanumeric code to another type of component.
8.1.1.changed
The specific components of vehicles using CNG and/or LNG in their propulsion system shall function in a correct and safe way as specified in this Regulation. 11 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html The materials of the components that are in contact with CNG/LNG shall be compatible with them (see Annex 5D). Those parts of components whose correct and safe functioning is liable to be influenced by CNG/LNG, high pressure or vibrations has to be submitted to relevant test procedures described in the annexes to this Regulation. In particular the provisions of paragraphs 8.2. to 8.11. are to be fulfilled for CNG components. For LNG components, the provisions of paragraphs 8.12. to 8.21. shall be fulfilled. The specific components of vehicles using CNG/LNG in their propulsion system shall comply with relevant electromagnetic compatibility (EMC) requirements according to UN Regulation No. 10, 03 series of amendments, or equivalent.
8.2.2.added
CNG-1, CNG-2 and CNG-3 containers of welded construction are not permitted.
8.3.1.changed
The CNG container shall be equipped at least with the following components, which may be either separate or combined: The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
11.3.changed
Every flexible fuel line assembly that is applied in the high and medium pressure (Class 0, 1 1, 5 and 5) 6) according to the classification, Classification as described in paragraph 3. 3 of this Regulation, shall be tested at the pressure twice the working pressure.
17.4.1.changed
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval; 12 12 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html.
18.1.2.1.changed
Notwithstanding the provisions of paragraph 18.1.2. above, no separate type approval of the CNG/LNG electronic control unit is required if the CNG/LNG electronic control unit is integrated into the engine electronic control unit and is covered with a vehicle installation type approval according to Part II of this Regulation and to UN Regulation No. 10. The vehicle type approval shall also be pursuant to the applicable provisions laid down in Annex 4H of this Regulation.
18.1.8.3.changed
The label shall be installed on the front and rear of the vehicle of category M2 M 2 or M3 and on the outside of the doors on the right-hand side (left hand drive vehicles), left-hand side (right hand drive vehicles).
18.1.8.4.changed
A label shall be placed adjacent to the CNG and/or LNG fill receptacle stating the fuelling requirements. requirements with the following data: (a) The marking "CNG" and/or "LNG"; (b) Working pressure [MPa]. The fuelling requirements shall be as recommended by the manufacturer. manufacturer:
18.3.4.8.changed
18.3.4.9.changed
LNG couplings; fuel line;
18.3.4.10.changed
LNG check valve or non-return valve; couplings;
18.3.4.11.changed
LNG pressure indicator check valve or fuel indicator; non-return valve;
18.3.4.12.changed
18.3.4.13.changed
18.3.4.14.added
Natural gas detector or gas tight housing, for category M vehicles.
18.3.5.7.deleted
18.3.5.5.changed
18.3.5.6.changed
18.5.1.3.added
Notwithstanding the provisions of paragraph 18.5.1.2.
(a) The automatic cylinder valve may stay in an open position during
commanded stop phases; and
(b) In the case where a fire alarm system is installed in the compartment
where a CNG combustion heater is located, the automatic cylinder valve(s)
may be opened by an electronic control unit for the purpose of permitting its
operation to warm the engine coolant.
18.5.1.4.added
If the automatic cylinder valve is closed during commanded stop phases, the
valve shall comply with paragraph 2.2.4. of Annex 4A.
18.5.2.1.changed
The pressure relief device (temperature triggered) shall be fitted to the CNG fuel container(s) in such a manner that can discharge into the gas-tight housing if that gas-tight housing fulfils the requirements of paragraph 18.5.5. below. However, in case of vehicles of categories M and N where the container(s) is (are) fitted outside the vehicle and on the roof or top of the bodywork of the vehicle, the pressure relief device (temperature triggered) shall be fitted to the fuel container(s) in such a manner that it can discharge the CNG only in a vertical upward direction.
18.5.6.2.changed
The PRD (pressure triggered) shall be fitted to the fuel container(s) in such a manner that it can discharge into the gas-tight housing if that gas-tight housing fulfils the requirements of paragraph 18.5.5. above. However, in case of vehicles of category M and N where the container(s) is (are) fitted outside the vehicle and on the roof or on the top of the bodywork of the vehicle, the pressure relief device (pressure triggered) shall be fitted to the fuel container(s) in such a manner that it can discharge the CNG only in a vertical upward direction.
18.6.1.3.added
Notwithstanding the provisions of paragraph 18.6.1.2., the automatic valve
may stay in an open position during commanded stop phases.
18.6.1.4.added
If the automatic valve is closed during commanded stop phases, the valve
shall comply with paragraph 2.2.4. of Annex 4A.
18.7.2.changed
The CNG rigid fuel line may be replaced by a flexible fuel line if used in Class 0, 1, 2, or 2. 6.
18.11.2.changed
Vehicles with more than one fuel system shall have a fuel selection system to ensure that no more than one which shall prevent both a flow of gaseous fuel at into the same time is supplied to petrol or diesel tank and a flow of petrol or diesel into the engine for gaseous fuel tank, even in the case of a limited duration. "Dual-fuel" vehicles, using diesel as fault of the primary fuel for igniting the air/gas mixture, are allowed in cases where these engines and vehicles meet mandatory emission standards. selection system.
18.11.3.changed
The electrical connections and components in the gas-tight housing measures shall be constructed such that no sparks are generated. demonstrated during the type approval.
18.11.4.added
The electrical connections and components in the gas-tight housing shall be
constructed such that no sparks are generated.
19.1.changed
The conformity of production procedures shall comply with those set out in the Agreement, Appendix 2 (E/ECE/324-E/ECE/TRANS/505/Rev.2). Schedule 1 (E/ECE/TRANS/505/Rev.3).
24.3.changed
24.7.changed
Notwithstanding the provisions of paragraphs 24.5. and 24.6., Contracting Parties applying this Regulation shall not refuse to grant extensions of type approvals for existing types of component or vehicle types which have been issued according to this Regulation without taking into account the provisions of the 01 series of amendments to this Regulation. Annex 1A Annex 1A Essential characteristics of the CNG/LNG components
24.8.added
As from the official date of entry into force of the 02 series of amendments to this
Regulation, no Contracting Party applying this Regulation shall refuse to grant or
refuse to accept type approval under this Regulation as amended by the 02 series of
amendments.
24.9.added
As from 1 September 2017 Contracting Parties applying this Regulation shall grant
approvals only if the type of components to be approved meets the requirements of
Part I of this Regulation as amended by the 02 series of amendments to this
Regulation.
24.10.added
As from 1 September 2018 Contracting Parties applying this Regulation shall grant
approvals only if the vehicle type to be approved meets the requirements of Part II of
this Regulation as amended by the 02 series of amendments to this Regulation.
24.11.added
As from 1 September 2019 Contracting Parties applying this Regulation may refuse to
recognize approvals of a type of vehicle which have not been granted in accordance
with Part II of this Regulation as amended by the 02 series of amendments to this
Regulation.
24.12.added
Contracting Parties applying this Regulation shall not refuse to grant extensions of
type approvals for existing types of component or vehicle types which have been
issued according to this Regulation without taking into account the provisions of the
02 series of amendments to this Regulation.
24.13.added
Notwithstanding paragraphs 24.11. and 24.12., Contracting Parties applying this
Regulation shall continue to accept type approvals granted to the preceding series of
amendments, which are not affected by the 02 series of amendments.
24.14.added
Notwithstanding the transitional provisions above, Contracting Parties whose
application of this Regulation comes into force after the date of entry into
force of the most recent series of amendments are only obliged to accept type
approval granted in accordance with the 02 series of amendments.
Annex 1A
Annex 1A
Essential characteristics of the CNG/LNG components
1.2.4.5.4.changed
1 Strike out what does not apply. 2 Specify the tolerance. Annex 1A
1.2.4.5.4.changed
1 Specify the tolerance. 2 Strike out what does not apply. Annex 1B
1.2.5.changed
Annex 2A Annex 2A Arrangement of the CNG/LNG component type approval mark (See paragraph 7.2. of this Regulation) 110 R-012439 R-022439 "L" (or "M" or "C") a ≥ 8 mm The above approval mark affixed to the CNG and or LNG component shows that this component has been approved in Italy (E 3), pursuant to UN Regulation No. 110 under approval number 012439. 022439. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of UN Regulation No. 110 as amended by the 01 02 series of amendments. The letter "L" indicates that the product is suitable for use with LNG. The letter "M" indicates that the product is suitable in moderate temperatures. The letter "C" indicates that the product is suitable in cold temperatures. Annex 2B Annex 2B Communication (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of CNG/LNG component pursuant to UN Regulation No. 110
1.changed
CNG/LNG component considered: Container(s) or cylinder(s)2 Tank(s) or vessel(s)2 Pressure indicator2 Pressure relief valve2 Automatic valve(s)2 Excess flow valve2 Gas-tight housing2 Pressure regulator(s)2 Non-return valve(s) or check valve(s)2 Pressure relief device (PRD) (temperature triggered)2 Manual valve2 Flexible fuel lines2 Filling unit or receptacle2 Gas injector(s)2 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply. Annex 2B Gas flow adjuster2 Gas/air mixer2 Electronic control unit2 Pressure and temperature sensor(s)2 CNG filter(s)2 PRD (pressure triggered)2 Fuel rail2 Heat exchanger(s) / vaporizer(s)2 Natural gas detector(s)2 LNG filling receptacle(s)2 LNG pressure control regulator(s)2 LNG pressure and/or temperature sensor(s)2 LNG manual valve(s)2 LNG automatic valve(s)2 LNG non-return valve(s)2 LNG pressure relief valve(s)2 LNG excess flow valve(s)2 LNG fuel pump(s)2
1.changed
Additional information concerning the type approval of a type of CNG/LNG components pursuant to UN Regulation No. 110
1.9.changed
1 Specify the tolerance. Annex 2B - Addendum
1.31.changed
Annex 2C Annex 2C Arrangement of approval marks Model A (See paragraph 17.2. of this Regulation) 110 R-012439 R-022439 "L" (or "M" or "C") a ≥ 8 mm The above approval mark affixed to a vehicle shows that the vehicle has, with regard to the installation of CNG/LNG system for the use of natural gas for propulsion, been approved in Italy (E 3), pursuant to UN Regulation No. 110 under approval number 012439. 022439. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of UN Regulation No. 110 as amended by the 01 02 series of amendments. The letter "L" indicates that the product is suitable for use with LNG. The letter "M" indicates that the product is suitable in moderate temperatures. The letter "C" indicates that the product is suitable in cold temperatures. Model B (See paragraph 17.2. of this Regulation) 110 012439 022439 "L" 83 051628 (or "M" or "C") a ≥ 8 mm The above approval mark affixed to a vehicle shows that the vehicle has, with regard to the installation of CNG/LNG system for the use of natural gas for propulsion, been approved in Italy (E 3), pursuant to UN Regulation No. 110 under approval number 012439. The first two digits of the approval number indicate that at the date the approval was granted in accordance with the requirements of Regulation No. 110 as amended by the 01 series of amendments and that Regulation No. 83 included the 05 series of amendments. The letter "L" indicates that the product is suitable for use with LNG. The letter "M" indicates that the product is suitable in moderate temperatures. The letter "C" indicates that the product is suitable in cold temperatures. Annex 2D Annex 2D Communication (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a vehicle type with regard to the installation of CNG/LNG system pursuant to Regulation No. 110
022439.added
The first two digits of the approval number indicate that at the date the approval
was granted in accordance with the requirements of UN Regulation No. 110 as amended by
the 02 series of amendments and that UN Regulation No. 83 included the 05 series of
amendments.
The letter "L" indicates that the product is suitable for use with LNG.
The letter "M" indicates that the product is suitable in moderate temperatures.
The letter "C" indicates that the product is suitable in cold temperatures.
Annex 2D
Annex 2D
Communication
(Maximum format: A4 (210 x 297 mm))
issued by: Name of administration:
Concerning:2 Approval granted
Approval extended
Approval refused
Approval withdrawn
Production definitively discontinued
of a vehicle type with regard to the installation of CNG/LNG system pursuant to UN
Regulation No. 110
11.changed
1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply. Annex 2D
18.changed
The following documents filed with the application or extension of approval can be obtained upon request: Drawings, diagrams and scheme plans on the components and the installation of the CNG/LNG equipment considered to be of importance for the purpose of this Regulation; Where applicable drawings of the various equipment and their position in the vehicle. Annex 3
6.3.2.5.deleted
6.3.2.6.deleted
6.3.2.1.changed
Steels shall be aluminium and/or silicon killed and produced to predominantly fine grain practice. The chemical composition of all steels shall be declared and defined at least by: (a) Carbon, manganese, aluminium and silicon contents in all cases; (b) Nickel, chromium, molybdenum, boron and vanadium contents, and any other alloying elements intentionally added. The following limits shall not be exceeded in the cast analysis: Tensile strength < 950 MPa ≥ 950 MPa Sulphur 0.020 per cent 0.010 per cent Phosphorus 0.020 per cent 0.020 per cent Sulphur and phosphorus 0.030 per cent 0.025 per cent Annex 3A When carbon-boron steel is used, a hardenability test in accordance with ISO 642, shall be performed on the first and last ingot or slab of each heat of steel. The hardness as measured in a distance of 7.9 mm from the quenched end, shall be within the range 33-53 HRC, or 327-560 HV, and shall be certified by the material manufacturer;
6.3.2.4.changed
The bending properties ultimate tensile strength of the welded stainless steel in from a finished cylinder shall not exceed 1,200 MPa. If the upper limit of the specified tensile strength for the steel exceeds 950 MPa, the steel from a finished liner cylinder shall be determined subjected to a sulphide stress cracking resistance test in accordance with paragraph A.3. (Appendix Appendix A to this annex). annex, paragraph A.3. and meet the requirements listed therein.6.3.3. Aluminium
6.3.3.4.changed
The mechanical properties of the aluminium alloy in the finished cylinder shall be determined in accordance with paragraph A.l. (Appendix A to this annex). The elongation for aluminium shall be at least 12 per cent. Annex 3A
6.3.4.1.changed
The material for impregnation may be thermosetting or thermoplastic resins. Examples of suitable matrix materials are epoxy, modified epoxy, polyester and vinyl ester thermosetting plastics, and polyethylene and polyamide thermoplastic material; Annex 3A
6.5.changed
For all types of cylinder the minimum actual burst pressure shall not be less than the values given in Table 6.3 of this annex. For type CNG-2, CNG-3 and CNG-4 designs the composite over-wrap shall be designed for high reliability under sustained loading and cyclic loading. This reliability shall be achieved by meeting or exceeding the composite reinforcement stress ratio values given in Table 6.3 of this annex. Stress ratio is defined as the stress in the fibre at the specified minimum burst pressure divided by the stress in the fibre at working pressure. The burst ratio is defined as the actual burst pressure of the cylinder divided by the working pressure. For type CNG-4 designs, the stress ratio is equal to the burst ratio. For type CNG-2 and CNG-3 designs (metal-lined, composite over-wrapped) stress ratio calculations shall include: Annex 3A (a) An analysis method with capability for non-linear materials (special purpose computer program or finite element analysis program); (b) Elastic-plastic stress-strain curve for liner material shall be known and correctly modelled; (c) Mechanical properties of composite materials shall be correctly modelled; Annex 3A (d) Calculations shall be made at: auto-frettage, zero after auto-frettage, working and minimum burst pressures; (e) Pre-stresses from winding tension shall be accounted for in the analysis; (f) Minimum burst pressure shall be chosen such that the calculated stress at minimum burst pressure divided by the calculated stress at working pressure meets the stress ratio requirements for the fibre used; (g) When analysing cylinders with hybrid reinforcement (two or more different fibre types), the load share between the different fibres shall be considered based on the different elastic moduli of the fibres. The stress ratio requirements for each individual fibre type shall be in accordance with the values given in Table 6.3. of this annex. Verification of the stress ratios may also be performed using strain gauges. An acceptable method is outlined in the informative Appendix E to this annex.
6.8.changed
The manufacturing inspection shall specify programmes and procedures for: (a) Manufacturing inspection, tests and acceptance criteria; and (b) Periodic in service inspection, tests and acceptance criteria. The interval of visual reinspection of the external cylinder surfaces shall be in accordance with paragraph 4.1.4. of this annex unless varied by the Type Approval Authority. The manufacturer shall establish the visual reinspection rejection criteria based on the results of pressure cycling tests performed on cylinders containing flaws. A guide for manufacturer's instructions for handling, use and inspection is provided in Appendix G to this annex. Annex 3A
6.9.changed
All cylinders shall be protected from fire with pressure relief devices. The cylinder, its materials, pressure relief devices and any added insulation or protective material shall be designed collectively to ensure adequate safety during fire conditions in the test specified in paragraph A.15. (Appendix A to this annex). Pressure relief devices shall be tested in accordance with paragraph A.24. (Appendix A to this annex). Annex 3A
6.12.changed
The exterior of cylinders shall meet the requirements of the environmental test conditions of paragraph A.14. (Appendix A to this annex). Exterior protection may shall be provided by using any of the following: (a) A surface finish giving adequate protection (e.g. metal sprayed on aluminium, anodizing); or (b) The use of a suitable fibre and matrix material (e.g. carbon fibre in resin); or (c) A protective coating (e.g. organic coating, paint) that shall meet the requirements of paragraph A.9. (Appendix A to this annex). Any coatings applied to cylinders shall be such that the application process does not adversely affect the mechanical properties of the cylinder. The coating shall be designed to facilitate subsequent in service inspection and the manufacturer shall provide guidance on coating treatment during such inspection to ensure the continued integrity of the cylinder. Manufacturers are advised that an environmental performance test that evaluates the suitability of coating systems is provided in the informative Appendix H to this annex.
6.17.changed
A design change is any change in the selection of structural materials or dimensional change not attributable to normal manufacturing tolerances. Minor design changes shall be permitted to be qualified through a reduced test program. Changes of design specified in Table 6.7 below shall require design qualification testing as specified in the table. Material design qualification test Relevant paragraph of this annex Steel Aluminium Resins Fibres Plastic liners Tensile properties 6.3.2.2. 6.3.3.4. 6.3.5. 6.3.6. Impact properties 6.3.2.3. Bending properties 6.3.2.4. Weld examination 6.3.2.5. Sulphide stress cracking resistance 6.3.2.6. 6.3.2.4. Sustained load crack resistance 6.3.3.3. Stress corrosion cracking 6.3.3.2. Shear strength 6.3.4.2. Glass transition temperature 6.3.4.3. Softening/Melting temperature 6.3.6. Fracture mechanics* 6.7. 6.7. * Not required if flawed cylinder test approach in paragraph A.7. of Appendix A to this annex is used. Annex 3A Impact test acceptable values Cylinder diameter D [mm] > 140 ≤ 140 Direction of testing transverse longitudinal Width of test piece [mm] 3-5 > 5 - 7.5 > 7.5 - 10 3 to 5 Test temperature [°C] [C] -50 -50 Impact strength [J/cm²] Mean of 3 specimens 30 35 40 60 Individual specimen 24 28 32 48 Minimum actual burst values and stress ratios CNG-1 CNG-2 CNG-3 CNG-4 All-metal Hoop-wrapped Fully-wrapped All-composite Burst Stress Burst Stress Burst Stress Burst pressure ratio pressure ratio pressure ratio pressure [MPa] [MPa] [MPa] [MPa] [MPa] [MPa] [MPa] All metal 45 Glass 2.75 50 1) 3.65 70 1) 3.65 73 Aramid 2.35 47 3.10 60 1) 3.1 62 Carbon 2.35 47 2.35 47 2.35 47 2) 2) 2) Hybrid Note 1) - Minimum actual burst pressure. In addition, calculations shall be performed in accordance with paragraph 6.5. of this annex to confirm that the minimum stress ratio requirements are also met. Note 2) - Stress ratios and burst pressures shall be calculated in accordance with paragraph 6.5. of this annex. Cylinder design qualification tests Cylinder type Test and annex reference CNG-1 CNG-2 CNG-3 CNG-4 A.12. Burst X* X X X A.13. Ambient temperature/cycle X* X X X A.14. Acid environment test X X X A.15. Bonfire X X X X A.16. Penetration X X X X A.17. Flaw tolerance X X X X A.18. High temperature creep X X X A.19. Stress rupture X X X A.20. Drop test X X A.21. Permeation X A.24. PRD performance X X X A.25. Boss torque test X X A.27. Natural gas cycling X A.6. LBB assessment X X A.7. Extreme temperature/cycle X X X X Notes: X = required * = Not required for cylinders designed to ISO 9809 (ISO 9809 already provides for these tests). Annex 3A Batch tests Cylinder type Test and annex reference CNG-1 CNG-2 CNG-3 CNG-4 A.12. Burst X X X X A.13. Ambient temperature/cycle X X X X A.1. Tensile X X† X† A.2. Impact (steel) X X† X† A.9.2. Coating* X X X X X = required * = Except where no protective coating is used † = Tests on liner material Critical production inspection requirements Type Cylinder type Inspection requirements CNG-1 CNG-2 CNG-3 CNG-4 Critical dimensions X X X X Surface finish X X X X Flaws (ultrasonic or equivalent) X X X Hardness of metal cylinders and metal X X X liners Hydrostatic proof test X X X X Leak test X Markings X X X X X = required Annex 3A Change of design Type of test High temp: Permeation Creep A.18 A.21 CNG Stress Boss Cycling rupture torque A.19 A.25 PRD Burst ambient Flaw Hydrostatic temp: Environm. Bonfire Penetration tolerance Drop test Cycling performance Design change A.12 A.13 A.14 A.15 A.16 A.17 A.20 A.27 A.24 Fibre X X X* X† manufacturer Metallic cylinder or X X X* X X* X X* liner material Plastic liner X X X† material Fibre material X X X X X X X X† Resin material X X X X Diameter change X X ≤ 20 per cent Diameter change X X X X* X > 20 per cent Length change X X‡ ≤ 50 per cent Length change X X X‡ > 50 per cent Working pressure X X change ≤ 20 per cent@ Dome shape X X X† Opening size X X Coating change X End boss X† design Change in X X manuf. process Pressure relief X X device X = required * Test not required on metal (CNG-1) designs: † Test only required on all-composite (CNG-4) designs ‡ Test only required when length increases @ Only when thickness changes proportional to diameter and/or pressure change. Annex 3A
11.1.changed
On each cylinder the manufacturer shall provide clear permanent markings not less than 6 mm high. Marking shall be made either by labels incorporated into resin coatings, labels attached by adhesive, low stress stamps used on the thickened ends of type CNG-1 and CNG-2 designs, or any combination of the above. Adhesive labels and their application shall be in accordance with ISO 7225, or an equivalent standard. Multiple labels are allowed and should be located such that they are not obscured by mounting brackets. Each cylinder complying with this annex shall be marked as follows: (a) Mandatory information: (i) "CNG ONLY"; (ii) "DO NOT USE AFTER XX/XXXX", where "XX/XXX" identifies the month and year of expiry;1 (iii) Manufacturer's identification; (iv) Cylinder identification (applicable part number and a serial number unique for every cylinder); (v) Working pressure and temperature; (vi) ECE Regulation number, along with cylinder type and certification registration number; 1 The expiry date shall not exceed the specified service life. The expiry date may be applied to the cylinder at the time of dispatch, provided that the cylinders have been stored in a dry location without internal pressure. Annex 3A (vii) The pressure relief devices and/or valves which are qualified for use with the cylinder, or the means for obtaining information on qualified fire protection systems; (viii) When labels are used, all cylinders shall have a unique identification number stamped on an exposed metal surface to permit tracing in the event that the label is destroyed. (b) Non-mandatory information: On a separate label(s) the following non-mandatory information may be provided: (i) Gas temperature range, e.g. -40 °C to 65 °C; (ii) Nominal water capacity of the cylinder to two significant numbers. e.g. 120 litres; (iii) Date of original pressure test (month and year). The markings shall be placed in the listed sequence but the specific arrangement may be varied to match the space available. An acceptable example of mandatory information is: CNG ONLY Manufacturer/Part Number/Serial Number 20 MPa/15 °C C ECE R 110 CNG-2 (registration No. …) "Use Only Manufacturer-Approved Pressure Relief Device"
12.changed
Prior to dispatch from the manufacturers shop, every cylinder shall be internally clean and dried. Cylinders not immediately closed by the fitting of a valve, and safety devices if applicable, shall have plugs, which prevent entry of moisture and protect threads, fitted to all openings. A corrosion inhibitor (e.g. oil-containing) shall be sprayed into all steel cylinders and liners prior to dispatch. The manufacturer's statement of service and all necessary information to ensure the proper handling, use and in-service inspection of the cylinder shall be supplied to the purchaser. The statement shall be in accordance with Appendix D to this annex. Annex 3A – Appendix A Annex 3A - Appendix A Test methods A.1. Tensile tests, steel and aluminium A tensile test shall be carried out on the material taken from the cylindrical part of the finished cylinder using a rectangular test piece shaped in accordance with the method described in ISO 9809 for steel and ISO 7866 for aluminium. For cylinders with welded stainless steel liners, tensile tests shall be also carried out on material taken from the welds in accordance with the method described in paragraph 8.4. of EN 13322-2. The two faces of the test pieces representing the inside and outside surface of the cylinder shall not be machined. The tensile test shall be carried out in accordance with ISO 6892. Note - Attention is drawn to the method of measurement of elongation described in ISO 6892, particularly in cases where the tensile test piece is tapered, resulting in a point of fracture away from the middle of the gauge length. A.2. Impact test, steel cylinders and steel liners The impact test shall be carried out on the material taken from the cylindrical part of the finished cylinder on three test pieces in accordance with ISO 148. The impact test pieces shall be taken in the direction as required in Table 6.2 of Annex 3A from the wall of the cylinder. For cylinders with welded stainless steel liners, impact tests shall be also carried out on material taken from the weld in accordance with the method described in paragraph 8.6. of EN 13322-2. The notch shall be perpendicular to the face of the cylinder wall. For longitudinal tests the test piece shall be machined all over (on six faces), if the wall thickness does not permit a final test piece width of 10 mm, the width shall be as near as practicable to the nominal thickness of the cylinder wall. The test pieces taken in transverse direction shall be machined on four faces only, the inner and outer face of the cylinder wall unmachined. A.3. Sulphide stress cracking test for steel Except as identified in the following, testing shall be conducted in accordance with Method A-NACE Standard Tensile Test procedures, as described in NACE Standard TM0177-96. Tests shall be conducted on a minimum of three tensile specimens with a gauge diameter of 3.81 mm (0.150 inches) machined from the wall of a finished cylinder or liner. The specimens shall be placed under a constant tensile load equal to 60 per cent of the specified minimum yield strength of the steel, immersed in a solution of distilled water buffered with 0.5 per cent (mass fraction) sodium acetate trihydrate and adjusted to an initial pH of 4.0, using acetic acid. The solution shall be continuously saturated at room temperature and pressure with 0.414 kPa (0.06 psia) hydrogen sulphide (balance nitrogen). The tested specimens shall not fail within a test duration of 144 hours. A.4. Corrosion tests, aluminium Corrosion tests for aluminium alloys shall be carried out in accordance with Annex A of ISO/DIS 7866 and meet the requirements therein. Annex 3A – Appendix A A.5. Sustained load cracking tests, aluminium The resistance to SLC shall be carried out in accordance with Annex D of ISO/DIS 7866 and shall meet the requirements therein; A.6. Leak-Before-Break (LBB) performance test Annex 3A – Appendix A Three finished cylinders shall be pressure cycled between not more than 2 MPa and nor less than 30 MPa at a rate not to exceed 10 cycles per minute. All cylinders shall fail by leakage. A.7. Extreme temperature pressure cycling Finished cylinders, with the composite wrapping free of any protective coating, shall be cycle tested, without showing evidence of rupture, leakage, or fibre unravelling, as follows: (a) Condition for 48 hours at zero pressure, 65 °C or higher, and 95 per cent or greater relative humidity. The intent of this requirement shall be deemed met by spraying with a fine spray or mist of water in a chamber held at 65 °C; (b) Hydrostatically pressurized for 500 cycles times the specified service life in years between not more than 2 MPa and not less than 26 MPa at 65 °C or higher and 95 per cent humidity; (c) Stabilize at zero pressure and ambient temperature; (d) Then pressurize from not more than 2 MPa to not less than 20 MPa for 500 cycles times the specified service life in years at -40 °C or lower; The pressure cycling rate of (b) shall not exceed 10 cycles per minute. The pressure cycling rate of (d) shall not exceed 3 cycles per minute unless a pressure transducer is installed directly within the cylinder. Adequate recording instrumentation shall be provided to ensure the minimum temperature of the fluid is maintained during the low temperature cycling. Following pressure cycling at extreme temperatures, cylinders shall be hydrostatically pressured to failure in accordance with the hydrostatic burst test requirements, and achieve a minimum burst pressure of 85 per cent of the minimum design burst pressure. For type CNG-4 designs, prior to the hydrostatic burst test the cylinder shall be leak tested in accordance with paragraph A.10. below. A.8. Brinell hardness test Hardness tests shall be carried out on the parallel wall at the centre and a domed end of each cylinder or liner in accordance with ISO 6506. The test shall be carried out after the final heat treatment and the hardness values thus determined shall be in the range specified for the design. A.9. Coating tests (mandatory if paragraph 6.12.(c)) of Annex 3A is used) A.9.1. Coating performance tests Coatings shall be evaluated using the following test methods, or using equivalent national standards. (a) Adhesion testing in accordance with ISO 4624 using Method A or B as applicable. The coating shall exhibit an adhesion rating of either 4A or 4B, as applicable; Annex 3A – Appendix A (b) Flexibility in accordance with ASTM D522 Mandrel Bend Test of Attached Organic Coatings, using Test Method B with a 12.7 mm (0.5 inch) mandrel at the specified thickness at -20 °C. Samples for the flexibility test shall be prepared in accordance with the ASTM D522 standard. There shall not be any visually apparent cracks; Annex 3A – Appendix A (c) Impact resistance in accordance with ASTM D2794 Test method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact). The coating at room temperature shall pass a forward impact test of 18 J (160 in-lbs); (d) Chemical resistance when tested in general accordance with ASTM D1308 Effect of Household Chemicals on Clear and Pigmented Organic Finishes. The tests shall be conducted using the Open Spot Test Method and 100 hour exposure to a 30 per cent sulfuric acid solution (battery acid with a specific gravity of 1.219) and 24 hours exposure to a polyalkalene glycol (e.g. brake fluid). There shall be no evidence of lifting, blistering or softening of the coating. The adhesion shall meet a rating of 3 when tested in accordance with ASTM D3359; (e) Minimum 1,000 hours exposure in accordance with ASTM G53 Practice for Operating Light- and Water-Exposure Apparatus (Fluorescent W-Condensation Type) for Exposure of non-metallic Materials. There shall be no evidence of blistering, and adhesion shall meet a rating of 3 when tested in accordance with ISO 4624. The maximum gloss loss allowed is 20 per cent; (f) Minimum 500 hours exposure in accordance with ASTM B117 Test Method of Salt Spray (Fog) Testing. Undercutting shall not exceed 3 mm at the scribe mark, there shall be no evidence of blistering, and adhesion shall meet a rating of 3 when tested in accordance with ASTM D3359; (g) Resistance to chipping at room temperature using the ASTM D3170 Chipping Resistance of Coatings. The coating shall have a rating of 7A or better and there shall not be any exposure of the substrate. A.9.2. Coating batch tests (a) Coating thickness The thickness of the coating shall meet the requirements of the design when tested in accordance with ISO 2808; (b) Coating adhesion The coating adhesion strength shall be measured in accordance with ISO 4624, and shall have a minimum rating of 4 when measured using either Test Method A or B, as appropriate. A.10. Leak test Type CNG-4 designs shall be leak tested using the following procedure (or an acceptable alternative); (a) Cylinders shall be thoroughly dried and pressurized to working pressure with dry air or nitrogen, and containing a detectable gas such as helium; Annex 3A – Appendix A (b) Any leakage measured at any point that exceeds 0.004 standard cm3/h shall be cause for rejection. A.11. Hydraulic test One of the following two options shall be used: Option 1: Water jacket test Annex 3A – Appendix A (a) The cylinder shall be hydrostatically tested to at least 1.5 times working pressure. In no case may the test pressure exceed the auto-frettage pressure; (b) Pressure shall be maintained for a sufficiently long period (at least 30 seconds) to ensure complete expansion. Any internal pressure applied after auto-frettage and previous to the hydrostatic test shall not exceed 90 per cent of the hydrostatic test pressure. If the test pressure cannot be maintained due to failure of the test apparatus, it is permissible to repeat the test at a pressure increased by 700 kPa. Not more than 2 such repeat rests are permitted; (c) The manufacturer shall define the appropriate limit of permanent volumetric expansion for the test pressure used, but in no case shall the permanent expansion exceed 5 per cent of the total volumetric expansion measured under the test pressure. For type CNG-4 designs, the elastic expansion shall be established by the manufacturer. Any cylinders not meeting the defined rejection limit shall be rejected and either destroyed or used for batch test purposes. Option 2: Proof pressure test The hydrostatic pressure in the cylinder shall be increased gradually and regularly until the test pressure, at least 1.5 times the working pressure, is reached. The cylinder test pressure shall be held for a sufficiently long period (at least 30 seconds) to ascertain that there is no tendency for the pressure to decrease and that tightness is guaranteed. A.12. Hydrostatic pressure burst test (a) The rate of pressurisation shall not exceed 1.4 MPa per second (200 psi/second) at pressures in excess of 80 per cent of the design burst pressure. If the rate of pressurisation at pressures in excess of 80 per cent of the design burst pressure exceeds 350 kPa/second (50 psi/second), then either the cylinder shall be placed schematically between the pressure source and the pressure measurement device, or there shall be a 5 second hold at the minimum design burst pressure; (b) The minimum required (calculated) burst pressure shall be at least 45 MPa, and in no case less than the value necessary to meet the stress ratio requirements. Actual burst pressure shall be recorded. Rupture may occur in either the cylindrical region or the dome region of the cylinder. A.13. Ambient temperature pressure cycling Pressure cycling shall be performed in accordance with the following procedure: (a) Fill the cylinder to be tested with a non-corrosive fluid such as oil, inhibited water or glycol; Annex 3A – Appendix A (b) Cycle the pressure in the cylinder between not more than 2 MPa and not less than 26 MPa at a rate not to exceed 10 cycles per minute. The number of cycles to failure shall be reported, along with the location and description of the failure initiation. A.14. Acid environment test Annex 3A – Appendix A On a finished cylinder the following test procedure should be applied: (a) Exposing a 150 mm diameter area on the cylinder surface for 100 hours to a 30 per cent sulfuric acid solution (battery acid with a specific gravity of 1.219) while the cylinder is held at 26 MPa; (b) The cylinder shall then be burst in accordance with the procedure defined in paragraph A.12. above and provide a burst pressure that exceeds 85 per cent of the minimum design burst pressure. A.15. Bonfire test A.15.1. General The bonfire tests are designed to demonstrate that finished cylinders complete with the fire protection system (cylinder valve, pressure relief devices and/or integral thermal insulation) specified in the design will not burst when tested under the specified fire conditions. Extreme caution shall be exercised during fire testing in the event that cylinder rupture occurs; A.15.2. Cylinder set-up Cylinders shall be placed horizontally with the cylinder bottom approximately 100 mm above the fire source; Metallic shielding shall be used to prevent direct flame impingement on cylinder valves, fittings, and/or pressure relief devices. The metallic shielding shall not be in direct contact with the specified fire protection system (pressure relief devices or cylinder valve). Any failure during the test of a valve, fitting or tubing that is not part of the intended protection system for the design shall invalidate the result. A.15.3. Fire source A uniform fire source of 1.65 m length shall provide direct flame impingement on the cylinder surface across its entire diameter. Any fuel may be used for the fire source provided it supplies uniform heat sufficient to maintain the specified test temperatures until the cylinder is vented. The selection of fuel should take into consideration air pollution concerns. The arrangement of the fire shall be recorded in sufficient detail to ensure the rate of heat input to the cylinder is reproducible. Any failure or inconsistency of the fire source during a test invalidates the result. A.15.4. Temperature and pressure measurements Surface temperatures shall be monitored by at least three thermocouples located along the bottom of the cylinder and spaced not more than 0.75 m apart. Metallic shielding shall be used to prevent direct flame impingement on the thermocouples. Alternatively, thermocouples may be inserted into blocks of metal measuring less than 25 square mm. The pressure inside the cylinder shall be measured by a pressure sensor without modify the configuration of the system under test. Annex 3A – Appendix A Thermocouple temperatures and the cylinder pressure shall be recorded at intervals of every 30 seconds or less during the test. A.15.5. General test requirements Cylinders shall be pressurized with natural gas and tested in the horizontal position at both: Annex 3A – Appendix A (a) Working pressure; (b) 25 per cent of the working pressure. Immediately following ignition, the fire shall produce flame impingement on the surface of the cylinder along the 1.65 m length of the fire source and across the cylinder diameter. Within 5 minutes of ignition, at least one thermocouple shall indicate a temperature of at least 590 °C. This minimum temperature shall be maintained for the remaining duration of the test. A.15.6. Cylinders 1.65 m length or less The centre of the cylinder shall be positioned over the centre of the fire source; A.15.7. Cylinders greater than 1.65 m length If the cylinder is fitted with a pressure relief device at one end, the fire source shall commence at the opposite end of the cylinder. If the cylinder is fitted with pressure relief devices at both ends, or at more than one location along the length of the cylinder, the centre of the fire source shall be centred midway between the pressure relief devices that are separated by the greatest horizontal distance. If the cylinder is additionally protected using thermal insulation, then two fire tests at service pressure shall be performed, one with the fire centred midway along the cylinder length, and the other with the fire commencing at one of the cylinder ends. A.15.8. Acceptable results The cylinder shall vent through a pressure relief device. A.16. Penetration tests A cylinder pressurised to 20 MPa ± 1 MPa with compressed gas shall be penetrated by an armour piercing bullet with a diameter of 7.62 mm or greater. The bullet shall completely penetrate at least one side wall of the cylinder. For type CNG-2, CNG-3 and CNG-4 designs, the projectile shall impact the side wall at an approximate angle of 45°. The cylinder shall reveal no evidence of fragmentation failure. Loss of small pieces of material, each not weighing more than 45 grams, shall not constitute failure of the test. The approximate size of entrance and exit openings and their locations shall be recorded. A.17. Composite flaw tolerance tests For type CNG-2, CNG-3 and CNG-4 designs only, one finished cylinder, complete with protective coating, shall have flaws in the longitudinal direction cut into the composite. The flaws shall be greater than the visual inspection limits as specified by the manufacturer. Annex 3A – Appendix A The flawed cylinder shall then be pressure cycled from not more than 2 MPa to not less than 26 MPa for 3,000 cycles, followed by an additional 12,000 cycles at ambient temperature; The cylinder shall not leak or rupture within the first 3,000 cycles, but may fail by leakage during the last 12,000 cycles. All cylinders which complete this test shall be destroyed. A.18. High temperature creep test This test is required for all type CNG-4 designs, and all type CNG-2 and CNG-3 designs in which the glass transition temperature of the resin matrix Annex 3A – Appendix A does not exceed the maximum design material temperature given in paragraph 4.4.2. of Annex 3A by at least 20 °C. One finished cylinder shall be tested as follows: (a) The cylinder shall be pressurised to 26 MPa and held at a temperature of 100 °C for not less than 200 hours; (b) Following the test, the cylinder shall meet the requirements of the hydrostatic expansion test A.11., the leak test A.10., and the burst test A.12. above. A.19. Accelerated stress rupture test For type CNG-2, CNG-3, and CNG-4 designs only, one cylinder free of protective coating shall be hydrostatically pressurised to 26 MPa while immersed in water at 65 °C. The cylinder shall be held at this pressure and temperature for 1,000 hours. The cylinder shall then be pressured to burst in accordance with the procedure defined in paragraph A.12. above except that the burst pressure shall exceed 85 per cent of the minimum design burst pressure. A.20. Impact damage test One or more finished cylinders shall be drop tested at ambient temperature without internal pressurisation or attached valves. The surface onto which the cylinders are dropped shall be a smooth, horizontal concrete pad or flooring. One cylinder shall be dropped in a horizontal position with the bottom 1.8 m above the surface onto which it is dropped. One cylinder shall be dropped vertically on each end at a sufficient height above the floor or pad so that the potential energy is 488 J, but in no case shall the height of the lower end be greater than 1.8 m. One cylinder shall be dropped at a 45° angle onto a dome from a height such that the centre of gravity is at 1.8 m; however, if the lower end is closer to the ground than 0.6 m, the drop angle shall be changed to maintain a minimum height of 0.6 m and a centre of gravity of 1.8 m. Following the drop impact, the cylinders shall be pressure cycled from not more than 2 MPa to not less than 26 MPa for 1,000 cycles times the specified service life in years. The cylinders may leak but not rupture, during the cycling. Any cylinders completing the cycling test shall be destroyed. A.21. Permeation test This test is only required on type CNG-4 designs. One finished cylinder shall be filled with compressed natural gas or a 90 per cent nitrogen/10 per cent helium mixture to working pressure, placed in an enclosed sealed chamber at ambient temperature, and monitored for leakage for a time sufficient to establish a steady state permeation rate. The permeation rate shall be less than 0.25 ml of natural gas or helium per hour per litre water capacity of the cylinder. Annex 3A – Appendix A A.22. Tensile properties of plastics The tensile yield strength and ultimate elongation of plastic liner material shall be determined at -50 °C using ISO 3628, and meet the requirements of paragraph 6.3.6. of Annex 3A. A.23. Melting temperature of plastics Annex 3A – Appendix A Polymeric materials from finished liners shall be tested in accordance with the method described in ISO 306, and meet the requirements of paragraph 6.3.6. of Annex 3A. A.24. Pressure relief device requirements Pressure relief device specified by the manufacturer shall be shown to be compatible with the service conditions listed in paragraph 4. of Annex 3A and through the following qualification tests: (a) One specimen shall be held at a controlled temperature of not less than 95 °C and a pressure not less than test pressure (30 MPa) for 24 hours. At the end of this test there shall be no leakage or visible sign of extrusion of any fusible metal used in the design. (b) One specimen shall be fatigue tested at a pressure cycling rate not to exceed 4 cycles per minute as follows: (i) Held at 82 °C while pressured for 10,000 cycles between 2 MPa and 26 MPa; (ii) Held at -40 °C while pressure for 10,000 cycles between 2 MPa and 20 MPa. At the end of this test there shall be no leakage, or any visible sign of extrusion of any fusible metal used in the design. (c) Exposed brass pressure retaining components of pressure relief devices shall withstand, without stress corrosion cracking, a mercurous nitrate test as described in ASTM B154. The pressure relief device shall be immersed for 30 minutes in an aqueous mercurous nitrate solution containing 10 g of mercurous nitrate and 10 ml of nitric acid per litre of solution. Following the immersion, the pressure relief device shall be leak tested by applying an aerostatic pressure of 26 MPa for one minute during which time the component shall be checked for external leakage; Any leakage shall not exceed 200 cm3/h; (d) Exposed stainless steel pressure retaining components of pressure relief devices shall be made of an alloy type resistant to chloride induced stress corrosion cracking. A.25. Boss torque test The body of the cylinder shall be restrained against rotation and a torque of 500 Nm shall be applied to each end boss of the cylinder, first in the direction to tighten a threaded connection, then in the untightening direction, and finally again in the tightening direction. Annex 3A – Appendix A A.26. Resin shear strength Resin materials shall be tested on a sample coupon representative of the composite over-wrap in accordance with ASTM D2344, or an equivalent national standard. Following a 24-hour water boil the composite shall have a minimum shear strength of 13.8 MPa. A.27. Natural gas cycling test One finished cylinder shall be pressure cycled using compressed natural gas from less than 2 MPa to working pressure for 300 cycles. Each cycle, consisting of the filling and venting of the cylinder, shall not exceed 1 hour. The cylinder shall be leak tested in accordance with paragraph A.10. above Annex 3A – Appendix A and meet the requirements therein. Following the completion of the natural gas cycling the cylinder shall be sectioned and the liner/end boss interface inspected for evidence of any deterioration, such as fatigue cracking or electrostatic discharge. Note - Special consideration shall be given to safety when conducting this test. Prior to conducting this test, cylinders of this design shall have successfully passed the test requirements of paragraph A.12. above (hydrostatic pressure burst test), paragraph 8.6.3. of Annex 3A (ambient temperature pressure cycling test) and paragraph A.21. above (permeation test). Prior to conducting this test, the specific cylinders to be tested shall pass the test requirements of paragraph A.10. above (leak test). A.28. Bend test, welded stainless steel liners Bend tests shall be carried out on material taken from the cylindrical part of a welded stainless steel liner and tested in accordance with the method described in paragraph 8.5. of EN 13322-2. The test piece shall not crack when bent inwards around a former until the inside edges are not further apart than the diameter of the former. Annex 3A – Appendix B Annex 3A - Appendix B (Not allocated) Annex 3A – Appendix C Annex 3A - Appendix C (Not allocated) Annex 3A – Appendix D Annex 3A - Appendix D Report forms Note - This appendix is not a mandatory part of this annex. The following forms should be used: (1) Report of Manufacture and Certificate of Conformity - Required to be clear, legible and in the format of Form 1. (2) Report1 of Chemical Analysis of Material for Metallic Cylinders, Liners, or Bosses - Required essential elements, identification, etc. (3) Report1 of Mechanical Properties of Material for Metallic Cylinders and Liners - Required to report all tests required by this Regulation. (4) Report1 of Physical and Mechanical Properties of Materials for Non-Metallic Liners - Required to report all tests and information required in this Regulation. (5) Report1 of Composite Analysis - Required to report all tests and data required in this Regulation. (6) Report of Hydrostatic Tests, Periodic Pressure Cycling and Burst Tests - Required to report test and data required in this Regulation. Form 1: Report of Manufacturer and Certificate of Conformity Manufactured by: Located at: Regulatory Registration Number: Manufacturers Mark and Number: Serial Number: from ……… to ……… inclusive ……… Cylinder description: SIZE: Outside diameter: ………mm; Length: ………mm; Marks stamped on shoulder or on labels of the cylinder are: 1 Report Forms 2 through 6 shall be developed by the manufacturer and shall fully identify cylinders and requirements. Each report shall be signed by the Type Approval Authority and the manufacturer. Annex 3A – Appendix D Each cylinder was made in compliance with all requirements of Regulation UN Required reports of test results are attached. I hereby certify that all these test results proved satisfactory in every way and are in compliance with the requirements for the type listed above. Annex 3A – Appendix E Annex 3A - Appendix E Verification of stress ratios using strain gauges
10.changed
Each tank was made in compliance with all requirements of UN Regulation No. ... in accordance with the tank description above. Required reports of test results are attached.
2.2.4.changed
2.2.5.added
The CNG automatic valve shall be so designed to operate at temperatures as
specified in Annex 5O.
2.3.changed
The electrical system, if existing, shall be isolated from the body of the automatic valve. Isolation resistance shall be > 10 MΩ. MΩ.
2.4.changed
The automatic valve activated by an electric current shall be in a "closed" position when the current is switched off. Annex 4A
3.2.2.changed
The non-return valve shall be so designed as to be leak-proof (external) at a pressure of 1.5 times the working pressure (MPa) (see Annex 5B). Annex 4A
4.2.2.changed
The pressure relief valve and pressure relief device of in Class 1 6 shall be so designed as to be leak-proof at withstand a pressure of 1.5 times the working pressure (MPa) with the outlet closed off (see Annex 5B). off.
4.2.3.changed
The pressure relief valve and pressure relief device of Class 1 and Class 2 shall be so designed as to be leak-proof at twice a pressure of 1.5 times the working pressure (MPa) with the outlets outlet closed off. off (see Annex 5B).
4.2.4.changed
The pressure relief device valve of Class 2 shall be so designed as to open be leak-proof at twice the fuse at a temperature of 110 °C ± 10 °C. working pressure with the outlets closed off.
4.2.5.changed
The pressure relief valve of Class 0 device shall be so designed to operate open the fuse at temperatures from -40 a temperature of 110 °C to 85 ± 10 °C.
4.2.6.added
The pressure relief valve of Class 0 shall be so designed to operate at
temperatures from -40 °C to 85 °C.
4.2.7.changed
5.4.changed
The excess flow valve shall be designed with a bypass to allow for equalization of pressures. Annex 4A
6.3.added
The manual valve device in Class 6 shall be designed to withstand a pressure
of 1.5 times the working pressure.
6.4.changed
The LNG manual valve has device in Class 6 shall be designed to comply with the operate at temperatures as specified in Annex 5O."6.5. Manual valve device requirements One specimen shall be submitted to a fatigue test procedures at a pressure cycling rate not to exceed 4 cycles per minute as follows: held at 20 °C while pressured for the 2,000 cycles between 2 MPa and 26 MPa (for Class 5 component. Annex 4O Annex 4O Provisions on the approval of the LNG fuel pump 0) or between 2 MPa and declared working pressure (for Class 6).
7.1.changed
The materials constituting the PRD (pressure triggered) which are in contact with the CNG when operating, shall be compatible with the test CNG. In Annex 4A order to verify this compatibility, the procedure described in Annex 5D shall be used.
7.2.2.changed
The burst pressure of the PRD (pressure triggered) of Class 0 shall be 34 MPa ± 10 per cent at ambient temperature and at the maximum operating temperature as indicated in Annex 5O.
7.2.3.added
The PRD (pressure triggered) of Class 6, shall be so designed to operate at
temperatures as specified in the Annex 5O.
7.2.4.added
1.5 times working pressure at ambient temperature and at the maximum
operating temperature as indicated in Annex 5O.
7.4.2.2.2.changed
At the completion of the test, the Class 0 PRD (pressure triggered) burst pressure shall be 34 MPa ± 10 per cent at ambient temperature and at the maximum operating temperature as indicated in Annex 5O. Annex 4B Annex 4B Provisions on the approval of flexible fuel lines or hoses for CNG and hoses for LNG
7.4.2.2.3.added
At the completion of the test, the Class 6 PRD (pressure triggered) burst
pressure shall be at least 1.5 times working pressure at ambient temperature
and at the maximum operating temperature as indicated in Annex 5O.
Annex 4B
Annex 4B
Provisions on the approval of flexible fuel lines or hoses for
CNG and hoses for LNG
0.changed
The purpose of this annex is to determine the provisions on the approval of flexible hoses for use with CNG or LNG. This annex covers three types of CNG flexible hoses (a), (b), (c) and one type of LNG hose (d): (a) High pressure hoses (Class 0); 0, Class 6); (b) Medium pressure hoses (Class 1); (c) Low pressure hoses (Class 2); (d) LNG hoses (Class 5).
1.6.2.3.deleted
1.6.2.2.changed
The sealing interface type for the hose coupling shall be: (a) Sealing cone of swivel-nut type shall be of the type with a half vertical angle of 45°. 45°; or (b) Other couplings complying with the tests described in paragraph 1.7., as well as the tests mentioned in Annexes 5A and 5B. Annex 4B In the case of an interface type using a soft seal body (e.g. O-ring), the type of material chosen shall be tested in accordance with Annexes 5D, 5F and 5G. Couplings shall have complementary counterparts.1.6.2.3. The couplings can be made as swivel-nut type or as quick-connector type.
1.6.2.4.changed
It shall be impossible to disconnect the quick-connector type without specific measures or the use of dedicated tools. Annex 4B
1.7.2.1.changed
The test has to be completed with circulating oil having a temperature of 93 °C, and a minimum pressure of 26 MPa. MPa (Class 0) or declared working pressure (Class 6).
1.8.1.4.changed
2.1.3.changed
ISO 1307. Annex 4B
2.2.2.changed
The reinforcing interlayer(s) has (have) to be protected by a cover against corrosion. If for the reinforcing interlayer(s) corrosion-resistant-material is used (i.e. stainless-steel) a cover is not required. Annex 4B
2.3.2.changed
Tensile strength and elongation specific for thermoplastic material. Annex 4B
2.3.2.1.changed
Tensile strength and elongation at break according to ISO 527-2 with the following conditions: (a) Specimen type: type 1 BA; (b) Tensile speed: 20 mm/minute. The material has to be conditioned for at least 21 days at 23 °C and 50 per cent relative humidity prior to testing. Annex 4B Requirements: (a) Tensile strength not less than 20 MPa; (b) Elongation at break not less than 100 per cent.
2.4.1.2.changed
Resistance to n-hexane according to ISO 1817 with the following conditions: (a) Medium: n-hexane; Annex 4B (b) Temperature: 23 °C (tolerance according to ISO 1817); (c) Immersion period: 72 hours. Requirements: (a) Maximum change in volume 30 per cent; (b) Maximum change in tensile strength 35 per cent; Annex 4B (c) Maximum change in elongation at break 35 per cent.
2.4.2.2.changed
Resistance to n-hexane according to ISO 1817 with the following conditions: (a) Medium: n-hexane; (b) Temperature: 23 °C (tolerance according to ISO 1817); (c) Immersion period: 72 hours. Requirements: (a) Maximum change in volume 2 per cent; (b) Maximum change in tensile strength 10 per cent; (c) Maximum change in elongation at break 10 per cent. After storage in air with a temperature of 40 °C for a period of 48 hours the mass compared to the original value may not decrease more than 5 per cent. Annex 4B
2.4.2.3.changed
Resistance to ageing according to ISO 188 with the following conditions: (a) Temperature: 115 °C (test temperature = maximum operating temperature minus 10 °C); (b) Exposure period: 24 and 336 hours. Annex 4B After ageing the specimens have to be conditioned at 23 °C and 50 per cent relative humidity for at least 21 days prior to carrying out the tensile test according to paragraph 2.4.2.1. above. Requirements: (a) Maximum change in tensile strength 20 per cent after 336 hours ageing compared to the tensile strength of the 24 hours aged material; (b) Maximum change in elongation at break 50 per cent after 336 hours ageing compared to the elongation at break of the 24 hours aged material.
2.2.deleted
2.2.changed
2.2.2.changed
Class 1 and Class 2: 6: The CNG filter shall be so designed to withstand a pressure twice of 1.5 times the working pressure. pressure (MPa).
2.2.3.changed
Class 3: the 1 and Class 2: The CNG filter shall be so designed to withstand a pressure twice the relief pressure of the pressure relief valve on which it is subject. working pressure.
2.2.4.changed
2.2.changed
The CNG pressure and temperature sensors materials constituting the regulator which are classified in a Class according to contact with the scheme 1-1 in paragraph 3. heat exchange medium of this Regulation. the regulator when operating, shall be compatible with that fluid.
2.3.changed
The component shall comply with the test procedures provided for in Class 0 or Class 6 for the parts subject to high pressure and Classes 1, 2, 3 and 4 for the parts subject to medium and low pressure.
3.2.changed
The part of the pressure regulator shall be so designed to operate at temperatures which is in contact with pressure higher than 26 MPa is regarded as specified in Annex 5O. Annex 4E Annex 4E Provisions on the approval of the CNG pressure and temperature sensors Class 6.
3.2.1.changed
The LNG check valve Class 6 part of the pressure regulator shall be so designed as to withstand leak-proof (see Annex 5B) at a pressure of up to 1.5 times the working pressure (MPa) without leakage and deformation at cryogenic temperature. Annex 4N with the outlet(s) of that part closed off.
3.2.2.changed
The LNG check valve Class 6 part of the pressure regulator shall be so designed as to be leak-proof (external) at withstand a pressure of up to 1.5 times the working pressure (MPa) (see Annex 5B) with the temperatures given in Annex 5O. (MPa).
3.2.3.changed
3.2.3.1.added
The Class 0 part of the pressure regulator shall be leak-proof (see Annex 5B)
at a pressure up to 1.5 times the working pressure (MPa) with the outlet(s) of
that part closed off.
3.2.3.2.added
The Class 0 part of the pressure regulator shall withstand a pressure up to 1.5
times the working pressure (MPa).
3.2.3.3.added
The Class 1 and Class 2 part of the CNG pressure regulator shall be leak-
proof (see Annex 5B) at a pressure up to twice the working pressure.
3.2.3.4.added
The Class 1 and Class 2 part of the CNG pressure regulator shall withstand a
pressure up to twice the working pressure.
3.2.3.5.added
The Class 3 part of the CNG pressure regulator shall withstand a pressure up
to twice the relief pressure of the pressure relief valve, on which it is subject.
3.3.changed
The electrical system, if existing, pressure regulator shall be isolated from the body of the pressure and temperature sensors. Isolation resistance shall be > 10 MΩ. so designed to operate at temperatures as specified in Annex 4F 5O. Annex 4F 4E Annex 4E Provisions on the approval of the CNG filling unit (Receptacle) pressure and temperature sensors
2.2.changed
3.1.4.changed
The Class 1 and Class 2 part of the CNG pressure and temperature sensors shall withstand a which is in contact with pressure up to twice the working pressure. higher than 26 MPa is regarded as Class 6.
3.1.5.changed
The Class 3 6 part of the CNG pressure and temperature sensors shall withstand be leakproof at a pressure up to twice 1.5 times the relief working pressure of the pressure relief valve, on which it is subject. (MPa) (see Annex 5B).
3.1.6.changed
The electrical resistance Class 6 of the connected LNG filling receptacle CNG pressure and nozzle temperature sensors shall be not be greater than 10 Ω either in withstand a pressure up to 1.5 times the pressurized and un-pressurized state. Test shall be conducted prior to and after the endurance test. Annex 4K Annex 4K Provisions on the approval of the LNG working pressure control regulator (MPa).
3.1.7.changed
The Class 1 and Class 2 part of the CNG filling unit pressure and temperature sensors shall be conform withstand a pressure up to twice the requirements of Class 0 and follow the test procedures in Annex 5 with the following specific requirements. working pressure.
3.1.8.changed
The material constituting the gas flow adjuster which is in contact with Class 3 part of the CNG pressure and temperature sensors shall be compatible with withstand a pressure up to twice the CNG. In order to verify this compatibility relief pressure of the procedure specified in Annex 5D has to be used. pressure relief valve, on which it is subject.
3.3.changed
The electrical system, if existing, shall be isolated from the body of the pressure and temperature sensors. Isolation resistance shall be > 10 MΩ. Annex 4F Annex 4F Provisions on the approval of the CNG filling unit shall be free from leakage at a pressure of 1.5 times the working pressure (MPa) (see Annex 5B). (Receptacle)
2.2.changed
3.1.changed
The LNG CNG filling receptacle unit shall be conform to the requirements of Class 5 0 and follow the test procedures in Annex 5 with the following specific requirements: requirements.
3.3.added
The CNG filling unit shall be free from leakage at a pressure of 1.5 times the
working pressure (MPa) (see Annex 5B).
4.2.added
M2, M3, N2 and N3.3
1 Road Vehicles — Compressed Natural Gas (CNG) refuelling connector - Part 1: 20 MPa (200 bar)
connector.
2 Road vehicles — Compressed natural gas (CNG) refuelling connector — Part 2: 20 MPa (200 bar)
connector, size 2.
3 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document
ECE/TRANS/WP.29/78/Rev.3, para. 2. –
www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
Annex 4F
Figure 1changed
Key This area shall be kept free of all components. 1 Sealing surface equivalent to No. 110 O-ring of dimensions: Dimensions in millimetres 9.19 mm ± 0.127 mm ID Surface roughness < Ra 3.2 µm 2.62 mm ± 0.076 mm width Sealing surface finish: 0.8 µm to 0.05 µm Material hardness: 75 Rockwell (HRB 75) minimum a Minimum length of the receptacle which is clear of provisions for attachement of receptacle or protective caps. Annex 4F
2.2.changed
The switching off delay CNG gas/air mixer, gas injector or fuel rail shall conform to the requirements of the automatic valve after stalling of the engine may not be more than 5 seconds. Class 1 or 2 components, according to their classification.
2.3.3.added
The CNG gas injector or fuel rail of Class 6 shall withstand a pressure 1.5
times the declared working pressure.
2.3.3.1.added
The CNG gas injector or fuel rail of Class 6 shall be free from leakage at a
pressure 1.5 times the declared working pressure.
2.3.4.added
The CNG gas injector or fuel rail of Class 6 shall be shall be so designed to
operate at temperatures as specified in Annex 5O.
3.1.changed
The pressure regulator that material constituting the gas flow adjuster which is in contact with the pressure of CNG shall be compatible with the LNG is regarded as Class 5. CNG. In order to verify this compatibility the procedure specified in Annex 5D has to be used.
3.3.added
Annex 4G
3.3.2.changed
The CNG gas flow adjuster of Class 1 and Class 2 shall be so designed to operate at temperatures as specified in Annex 5O. Annex 4G
2.1.changed
The electronic control unit can be any device which controls the CNG/LNG demand of the engine and establishes the cut-off of the automatic valve in case of a switch off of the engine or a broken fuel supply pipe or in case of stalling of the engine, or during a crash.
2.1.1.added
Notwithstanding the provisions of paragraph 2.1., the automatic valve may
stay in an open position during commanded stop phases.
2.2.changed
The material constituting switch-off delay of the LNG heat exchanger - vaporizer which is in contact with automatic valve after stalling of the CNG when operating shall engine may not be compatible with the test CNG. In order to verify this compatibility, the procedure in Annex 5D shall be used. more than 2 seconds.
3.3.deleted
2.2.changed
The manufacturer of material constituting the receptacle may require a specific LNG nozzle type heat exchanger - vaporizer which is in contact with the CNG when operating shall be compatible with the test CNG. In order to verify this compatibility, the procedure in Annex 5D shall be used.
3.1.changed
The LNG pressure and/or temperature sensor test procedures filling receptacle shall be conform to the requirements of Class 5 and follow the test procedures in Annex 5 with the following specific requirements. requirements:
3.1.4.3.changed
The component shall be operated through 2 per cent of the total cycles as above at the appropriate maximum temperature specified at rated service pressure. The component shall comply with the leakage test of Annex 5B at the high temperature at the completion of the high temperature cycles. Annex 4J Following cycling and leakage re-test the component shall be capable of remove of the filling nozzle without spilling more than 30 cm3 LNG. Annex 4J
3.1.6.added
The electrical resistance of the connected LNG filling receptacle and nozzle
shall not be greater than 10 Ω either in the pressurized and un-pressurized
state. Test shall be conducted prior to and after the endurance test.
4.1.changed
3.1.changed
The natural gas detector shall be so designed pressure regulator that is in contact with the pressure of the LNG is regarded as to operate at temperatures as specified in Annex 5O. Class 5.
3.1.changed
The materials constituting LNG pressure and/or temperature sensor test procedures shall be conform to the LNG check valve which are requirements of Class 5 and follow the test procedures in contact Annex 5 with the LNG when operating, shall be compatible with the test LNG. In order to verify this compatibility the procedure described in Annex 5D shall be used. following specific requirements.
3.2.changed
Insulation resistance test. This test is designed to check for a potential failure of the insulation between the LNG pressure and/or temperature sensor connection pins and the housing. Apply 1,000 V DC between one of the connector pins and the housing of the LNG pressure and/or temperature sensor for at least 2 seconds. The minimum allowable resistance shall be > 10 MΩ. MΩ.
3.3.changed
The natural gas detector material constituting the LNG pressure and temperature sensors witch is in contact with the LNG when operating shall comply be compatible with relevant electromagnetic compatibility (EMC) requirements according the test LNG. In order to Regulation No. 10, 03 series of amendments, or equivalent. verify this compatibility, the procedure in Annex 4N Annex 4N Provisions on the approval of the automatic valve, check valve, pressure relief valve, excess flow valve, manual valve and non-return valve for LNG applications. 5D shall be used.
3.1.changed
3.2.changed
This test is designed to check for a potential failure of the insulation between the connection pins and the housing of the natural gas detector. Apply 1,000 V DC between one of the connector pins and the housing of the natural gas detector for at least 2 seconds. The minimum allowable resistance shall be 10 MΩ. MΩ.
3.3.changed
The LNG check valve has to natural gas detector shall comply with relevant electromagnetic compatibility (EMC) requirements according to UN Regulation No. 10, 03 series of amendments, or equivalent. Annex 4N Annex 4N Provisions on the test procedures approval of the automatic valve, check valve, pressure relief valve, excess flow valve, manual valve and non-return valve for the Class 5 component. LNG applications.
6.3.deleted
2.2.4.added
The LNG automatic valve shall be so designed to operate at temperatures as
specified in Annex 5O.
2.2.5.changed
The insulation resistance test. This test is designed to check for a potential failure of the insulation between the two-pin coil assembly and the LNG automatic valve casing. Apply 1,000 V DC between one of the connector pins and the housing of the automatic valve for at least 2 seconds. The minimum allowable resistance shall be 10 MΩ. MΩ.
3.1.added
The materials constituting the LNG check valve which are in contact with the
LNG when operating, shall be compatible with the test LNG. In order to
verify this compatibility the procedure described in Annex 5D shall be used.
3.2.1.added
The LNG check valve shall be so designed as to withstand a pressure of
1.5 times the working pressure (MPa) without leakage and deformation at
cryogenic temperature.
Annex 4N
3.2.2.added
The LNG check valve shall be so designed as to be leak-proof (external) at a
pressure of 1.5 times the working pressure (MPa) (see Annex 5B) with the
temperatures given in Annex 5O.
3.2.3.added
The LNG check valve, being in the normal position of use specified by the
manufacturer, is submitted to 7,000 operations at cryogenic temperature (see
Annex 5O); then it is deactivated. The check valve shall remain leak-proof
(external) at a pressure of 1.5 times the working pressure (MPa) (see
Annex 5B).
3.3.added
The LNG check valve has to comply with the test procedures for the Class 5
component.
4.1.added
The materials constituting the pressure relief valve which are in contact with
the LNG when operating, shall be compatible with the test LNG. In order to
verify this compatibility, the procedure described in Annex 5D shall be used.
6.3.changed
One specimen shall be submitted to a fatigue test at a pressure cycling pressure-cycling rate not to exceed 4 cycles per a minute as follows: held Held at 20 -162 °C or lower while pressured for 2,000 100 cycles between 0 and working pressure WP. The maximum torque on the valve shall than comply with 2 MPa times the force mentioned in Table 5.3 in Annex 5L. After the test the LNG manual valve shall comply with the external leak test in Annex 5B. If during this test icing occurs, the LNG manual valve may be de-iced and 26 MPa. dried.
6.4.added
The LNG manual valve has to comply with the test procedures for the Class 5
component.
Annex 4O
Annex 4O
Provisions on the approval of the LNG fuel pump
3.1.added
LNG fuel pump mounted inside the tank:
LNG compatibility test Annex 5D
Resistance to dry heat Annex 5F
Ozone ageing Annex 5G
Low temperature test Annex 5P
Annex 4O
Table 5changed
Test Class 0 Class 1 Class 2 Class 3 Class 4 Class 5 Class 6 Annex Overpressure or strength X X X X O X X 5A External leakage X X X X O X X 5B Internal leakage A A A A O A A 5C Durability tests A A A A O A A 5L CNG/LNG compatibility A A A A A A A 5D Corrosion resistance X X X X X A X 5E Resistance to dry heat A A A A A A A 5F Ozone ageing A A A A A A A 5G Burst/destructive tests X O O O O A X 5M Temperature cycle A A A A O A A 5H Pressure cycle X O O O O A X 5I Vibration resistance A A A A O A A 5N Operating temperatures X X X X X X X 5O LNG low temperature O O O O O X O 5P X = Applicable O = Not applicable A = As applicable Remarks: (a) Internal leakage: Applicable if the Class of the component consists of internal valve seats that are normally closed during engine "OFF" condition; (b) Durability test: Applicable if the Class of the component consists of integral parts that will move repeatedly during engine operation; (c) CNG compatibility, resistance to dry heat, ozone ageing: Applicable if the class of the component consists of synthetic / non-metallic parts; (d) Temperature cyclic test: Applicable if the class of the component consists of synthetic / non-metallic parts; (e) Vibration resistance test: Applicable if the Class of the component consists of integral parts that will move repeatedly during engine operation. The materials used for the components shall have written specifications that fulfil at least or exceed the (test) requirements laid down in this annex with respect to: (a) Temperature; (b) Pressure; (c) CNG/LNG compatibility; (d) Durability.
3.changed
Table 5.2 below shows the working and burst test pressures according to the classification of paragraph 2. of this Regulation. Classification of Working pressure Overpressure component [kPa] [kPa] Class 0 3,000 < p < 26,000 1.5 times the working pressure Class 1 450 < p < 3,000 1.5 times the working pressure Class 2 20 < p < 450 2 times the working pressure Class 3 450 < p < 3,000 2 times the relief pressure Class 5 as specified by the manufacturer 1.5 times the working pressure Class 6 as specified by the manufacturer 1.5 times the working pressure Annex 5B Annex 5B External leakage test
7.changed
Compliance with paragraphs 2. to 5. below is to be determined by connecting a length of tubing to the valve outlet. The open end of this outlet tube is to be located within an inverted graduated cylinder which is calibrated in cubic centimetres. The inverted cylinder is to be closed by a water tight seal. The apparatus is to be adjusted so that: (a) The end of the outlet tube is located approximately 13 mm above the water level within the inverted graduated cylinder, and (b) The water within and exterior to the graduated cylinder is at the same level. With these adjustments made, the water level within the graduated cylinder is to be recorded. With the valve in the closed position assumed as the result of normal operation, air or nitrogen at the specified test pressure is to be applied to the valve inlet for a test period of not less than 2 minutes. During this time, the vertical position of the graduated cylinder is to be adjusted, if necessary, to maintain the same water level within and exterior to it. Annex 5C At the end of the test period and with the water within and exterior to the graduated cylinder at the same level, the level of water within the graduated cylinder is again recorded. From the change of volume within the graduated cylinder, the leakage rate is to be calculated according to the following formula: V1 = Vt • 60 • ⎛⎜ 273 • P ⎞⎟ t ⎝ T 101.3 ⎠ 101 .3 Where: V1 = leakage rate, cubic centimetres of air or nitrogen per hour. Vt = increase in volume within graduated cylinder during test. t = time of test, minutes. P = barometric pressure during test, in kPa. T = ambient temperature during test, in K.
Annex 7changed
Provisions on LNG identification mark for vehicles of categories M2 and M3, N2 and N3 (Paragraph 18.1.8.2. of this Regulation) The sign consists of a sticker which shall be weather resistant. The colour and dimensions of the sticker shall fulfil the following requirements: Colours: Background: green Border: white or white reflecting Letters: white or white reflecting Dimensions: Border width: 4 - 6 mm Character height: ≥ 25 mm Character thickness: ≥ 4 mm Sticker width: 110 - 150 mm Sticker height: 80 - 110 mm The word "LNG" shall be centred in the middle of the sticker.