Compare versions of UN R112
Motor vehicle headlamps emitting an asymmetrical passing-beam or a driving-beam or both and equipped with filament lamps and/or Light-Emitting Diode (LED) modules
1.3.changed
1.3.1.changed
The trade name or mark; mark: (a) Lamps bearing the same trade name or mark but produced by different manufacturers shall be considered as being of different types; (b) Lamps produced by the same manufacturer differing only by the trade name or mark shall be considered as being of the same type.
1.3.5.changed
The kind of beam produced (passing-beam, driving-beam (passing beam, driving beam or both);
1.3.6.changed
The materials constituting category of filament light source used and/ or the lenses and coating, if any; LED module specific identification code(s);
1.3.7.changed
1.3.8.deleted
1.5.changed
The definitions given in UN Regulation No. 48 and its series of amendments in force at the time of application for type approval shall apply to this Regulation.
1.6.changed
References made in this Regulation to standard (étalon) filament lamp(s) light source(s) and to UN Regulation No. 37 shall refer to UN Regulation No. 37 and its series of amendments in force at the time of application for type approval. 1 Nothing in this Regulation shall prevent a Party to the Agreement applying this Regulation from prohibiting the combination of a headlamp incorporating a lens of plastic material approved under this Regulation with a mechanical headlamp-cleaning device (with wipers). 2 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.2, (R.E.3.) (ECE/TRANS/WP.29/78/Rev.6, para. 2. 2).
2.1.5.changed
2.4.added
In the case of a type of lamp differing only by the trade name or mark from a
type that has already been approved it shall be sufficient to submit:
2.4.1.added
A declaration by the lamp manufacturer that the type submitted is identical
(except in the trade name or mark) with and has been produced by the same
manufacturer as, the type already approved, the latter being identified by its
approval code;
2.4.2.added
Two samples bearing the new trade name or mark or equivalent
documentation.
3.2.changed
They shall comprise, on the lens and on the main body3, body 3, spaces of sufficient size for the approval mark and the additional symbols referred to in paragraph 4; these spaces shall be indicated on the drawings referred to in paragraph 2.2.1. above.
3.3.changed
Headlamps equipped with passing-beam designed to satisfy the requirements both of right-hand and of left-hand traffic shall bear markings indicating the two settings of the optical unit or LED module on the vehicle or of the filament lamp light source on the reflector; these markings shall consist of the letters "R/D" for the position for right-hand traffic and the letters "L/G" for the position for left-hand traffic.
3.5.1.changed
Shall bear the trade name or mark of the applicant. This marking shall be clearly legible and indelible; If the lens cannot be detached from the main body of the headlamp, a unique marking as per paragraph 4.2.5. shall be sufficient.
3.5.2.changed
Shall bear the specific identification code of the module. This marking shall be clearly legible and indelible. 3 If the lens cannot be detached from the main body of the headlamp, a unique marking as per paragraph 4.2.5. shall be sufficient. This specific identification code shall comprise the starting letters "MD" for "MODULE" followed by the approval marking without the circle as prescribed in paragraph 4.2.1. below and in the case several non-identical light source modules are used, followed by additional symbols or characters. This specific identification code shall be shown in the drawings mentioned in paragraph 2.2.1. above. The approval marking does not have to be the same as the one on the lamp in which the module is used, but both markings shall be from the same applicant.
3.5.3.added
If the LED module(s) are non-replaceable, the markings for LED module(s)
are not required.
4.2.2.2.changed
On headlamps designed to meet the requirements of both traffic systems by means of an appropriate adjustment of the setting of the optical unit or the filament lamp light source or LED module(s), a horizontal arrow with a head on each end, the heads pointing respectively to the left and to the right;
4.2.3.1.changed
On headlamps meeting the requirements of this Regulation which are so designed that the filament light source or LED module(s) producing the principal passing- beam passing-beam shall not be lit simultaneously with that of any other lighting function with which it may be reciprocally incorporated: an oblique stroke (/) shall be placed behind the symbol indicating the headlamp producing the passing- beam passing-beam in the approval mark. The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.2/Amend.1.
4.2.3.2.changed
On headlamps equipped with filament lamps light sources and meeting the requirements of Annex 4 to this Regulation only when supplied with a voltage of 6 V or 12 V, a symbol consisting of the number 24 crossed out by an oblique cross (x), shall be placed near the filament lamp light source holder. 4 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.6).
5.added
The requirements contained in sections 5. "General specifications" and
6.added
"Individual specifications" and in the Annexes referenced in the said
sections of UN Regulations Nos. 48, 53, 74 or 86, and their series of
amendments in force at the time of application for the lamp type approval
shall apply to this Regulation.
The requirements pertinent to each lamp and to the category/ies of vehicle on
which the lamp is intended to be installed shall be applied, where its
verification at the moment of lamp type approval is feasible.
5.2.1.changed
Headlamps shall be fitted with a device enabling them to be so adjusted on the vehicles as to comply with the rules applicable to them. Such a device need not be fitted on units in which the reflector and the diffusing lens cannot be separated, provided the use of such units is confined to vehicles on which the headlamp setting can be adjusted by other means. Where a headlamp providing a principal passing-beam and a headlamp providing a driving-beam, each equipped with its own filament lamp light source or LED module(s), the adjusting device shall enable the principal passing-beam passing- beam and the driving-beam to be adjusted individually.
5.3.1.changed
5.3.1.1.changed
The design of the device shall be such that the filament lamp light source can be fixed in no other position but the correct one6; 5 Technical requirements for filament light sources : see UN Regulation No. 37. 6 A headlamp is regarded as satisfying the requirements of this paragraph if the filament light source can be easily fitted into the headlamp and the positioning lugs can be correctly fitted into their slots even in darkness.
5.3.1.2.changed
The filament light source holder shall conform to the characteristics given in IEC Publication 60061. The holder data sheet relevant to the category of filament lamp light source used, applies.
5.3.1.3.added
A means of controlling the voltage at the terminals of the device, within the
limits as defined in UN Regulation No. 48, may, for convenience, be located
within the body of the headlamp. However, for the purposes of type approval
of the passing and/ or driving beam according to the provisions of this
Regulation, such means of voltage control shall not be considered to be part
of the headlamp and shall be disconnected during the testing to verify
performance according to the requirements of this Regulation.
5.3.2.1.changed
Electronic light source control gear(s), gear(s) associated with the operation of LED module(s), if applicable, shall be considered to be part of the headlamp; they may be part of the LED module(s);
5.4.changed
Headlamps designed to satisfy the requirements both of right hand and of left hand traffic may be adapted for traffic on a given side of the road either by an appropriate initial setting when fitted on the vehicle or by selective setting by the user. Such initial or selective setting may consist, for example, of fixing either the optical unit at a given angle on the vehicle or the filament lamp light source or LED module(s) producing the principal passing-beam at a given angle/position in relation to the optical unit. In all cases, only two different and clearly distinct settings, one for right hand and one for left-hand traffic, shall be possible, and the design shall preclude inadvertent shifting from one setting to the other or setting in an intermediate position. Where two different setting positions are provided for the filament lamp light source or LED module(s) producing the principal passing-beam, the components for attaching the filament lamp light source or LED module(s) producing the principal passing-beam passing- beam to the reflector must be so designed and made that, in each of its two settings, this filament lamp light source or LED module(s) will be held in position with the precision required for headlamps designed for traffic on only one side of the road. Conformity with the requirements of this paragraph shall be verified by visual inspection and, where necessary, by a test fitting.
5.6.changed
Light transmitting components made of plastic material shall be tested according to the requirements of Annex 6. A headlamp is regarded as satisfying the requirements of this paragraph if the filament lamp can be easily fitted into the headlamp and the positioning lugs can be correctly fitted into their slots even in darkness.
5.8.2.changed
Following the application of this (these) measure(s) the following requirements regarding the luminous intensity of the headlamp shall be met with the adjustment left unchanged compared to that for the original traffic direction: Instructions on the installation of lamps fitted with the measures are given in Regulation No. 48.
5.9.changed
In case of a passing-beam headlamp incorporating a light source or LED module(s) producing the principal passing-beam and having a total objective luminous flux which exceeds 2,000 lumens, a reference shall be made in 7 Instructions on the installation of lamps fitted with the measures are given in UN Regulation No. 48. item 9. of the communication form in Annex 1. The objective luminous flux of LED modules shall be measured as described in paragraph 5. of Annex 10.
5.10.changed
5.12.added
Instead of requirements of this Regulation, headlamps may conform with
requirements of the latest version of UN Regulation No. 149 as it relates to
headlamps emitting an asymmetric passing beam.
6.1.3.changed
Apart from LED module(s), the headlamps shall be checked by means of an uncoloured standard (étalon) filament lamp light source designed for a rated voltage of 12 V.
6.1.3.1.changed
During the checking of the headlamp, the voltage at the terminals of the filament lamp light source shall be regulated as to obtain the reference luminous flux at 13.2 V as indicated for each filament lamp light source at the relevant data sheet of UN Regulation No. 37. However, if a filament lamp light source of category H9 or H9B is used for the principal passing-beam, the applicant may choose the reference luminous flux at 12.2 V or 13.2 V as indicated in the relevant data sheet of UN Regulation No. 37 and a reference stating which voltage was chosen for type approval shall be made in item 9 in the communication form of Annex 1.
6.1.3.2.changed
In order to protect the standard (étalon) filament lamp light source during the process of photometric measurement it is permissible to carry out the measurements at a luminous flux that differs from the reference luminous flux at 13.2 V. If the Technical Service chooses to carry out measurements in such a manner, the luminous intensity shall be corrected by multiplying the measured value by the individual factor F lamp of the standard (étalon) filament lamp light source in order to verify the compliance with the photometric requirements where: F lamp = Φ reference / Φ test Φ reference is the reference luminous flux at 13,2 V as specified in the relevant data sheet of UN Regulation No. 37 Φ test is the actual luminous flux used for the measurement. However, where the reference luminous flux of 12.2 V as specified in the data sheet for the category H9 or H9B is chosen, this procedure is not permitted.
6.1.3.3.changed
The headlamp shall be considered acceptable if it meets the requirements of paragraph 6. with at least one standard (étalon) filament lamp, light source, which may be submitted with the headlamp.
Figure 1deleted
6.1.5.changed
In the case of headlamps equipped with LED module(s) and filament lamps, light sources, the part of the headlamp with filament lamp(s) light source(s) shall be tested according to paragraph 6.1.3. and the part of the headlamp with LED module(s) shall be evaluated according to the provisions of paragraph 6.1.4. and then added to the previous result obtained from the filament lamp(s) light source(s) tested.
6.2.2.changed
6.2.2.2.added
For horizontal adjustment: the "elbow – shoulder" part of the "cut-off" shall
be moved:
For right hand traffic from right to left and shall be horizontally positioned
after its movement so that:
(a) Above the line 0.2° D its "shoulder" shall not exceed the line A to the
left;
(b) The line 0.2° D or below its "shoulder" should cross the line A; and
(c) The kink of the "elbow" is basically located within +/-0.5 degrees to
the left or right of the V-V line;
or
For left hand traffic from left to right and shall be horizontally positioned
after its movement so that:
(a) Above the line 0.2 D its "shoulder" shall not exceed the line A to the
right;
(b) On the line 0.2° or below its "shoulder" cross the line A; and
(c) The kink of the "elbow" should be primarily on the V-V line;
6.2.4.changed
The passing-beam shall meet the luminous intensities at the test points referred to in the tables below and in Annex 3 Figure B (or mirrored about the VV line for left-hand traffic): 8 Such a special "passing-beam" headlamp may incorporate a driving-beam not subject to requirements. Headlamps for RH Traffic** Class A Headlamp Class B Headlamp Required luminous Required luminous Test point intensity intensity Test point designation cd cd angular coordinates - Degrees Max Min Max Min B 50 L 0.57U, 3.43L 350 350 BR 1.0 U, 2.5R 1,750 1,750 75 R 0.57D, 1.15R 5,100 10,100 75 L 0.57D, 3.43L 10,600 10,600 50 L 0.86D, 3.43L 13,200*** 13,200*** 50 R 0.86D, 1.72R 5,100 10,100 50 V 0.86D, 0 5,100 25 L 1.72D, 9.0L 1,250 1,700 25 R 1.72D, 9.0R 1,250 1,700 Any point in zone III (bounded by the following coordinates in degrees) 625 625 8L 8L 8R 8R 6R 1.5 R V-V 4L 1U 4U 4U 2U 1.5 U 1.5 U H-H H-H Any point in zone IV 1,700 2,500 (0.86D to 1.72D, 5.15 L to 5.15 R) Any point in zone I 17,600 < 2I* (1.72D to 4D, 9 L to 9 R) Note: In the table: Letter L means that the point is located on the left of VV line. Letter R means that the point is located on the right of VV line. Letter U means the point is located above HH line Letter D means the point or segment is located below HH line * Actual measured value at points 50R / 50L respectively ** For left-hand traffic, the letter R shall be replaced by letter L and vice versa. *** In case where a headlamp in which LED modules are producing a passing-beam in conjunction with an electronic light source control gear, the measured value shall not be more than 18,500 cd. Headlamps for RH Traffic** Angular coordinates Required luminous intensity- cd Test point Degrees Min 1 4U, 8L Points 1+2+3 2 4U, 0 3 4U, 8R 4 2U, 4L Points 4+5+6 5 2U, 0 6 2U, 4R 7 0, 8L 65 8 0, 4L 125
6.2.8.1.changed
One additional light source according to UN Regulation No. 37 or one or more additional LED module(s) may be used inside the passing-beam headlamp to contribute to bend lighting;
6.2.8.2.changed
One additional light source according to UN Regulation No. 37 and/or one or more LED module(s), inside the passing-beam headlamp, may be used for the purposes of generating infrared radiation. It/they shall only be activated at the same time as the principal light source or LED module(s). In the event that the principal light source or (one of) the principal LED module(s) fails, this additional light source and/or LED module(s) shall be automatically switched off;
6.3.2.changed
Irrespective of the type of light source (LED module(s) or filament light source(s)) used to produce the principal passing-beam, several light sources: (a) Either filament light sources listed in UN Regulation No. 37; or (b) LED module(s) may be used for each individual driving-beam.
6.3.3.1.changed
The point of intersection (HV) of lines h h and v v shall be situated within the isolux 80 per cent of maximum luminous intensity (Imax) (I max)
6.4.3.changed
Additional tests are made after the reflector has been moved vertically 2° 2° or at least into the maximum position, if less than 2°, from its initial position by means of the headlamps adjusting device. Having re-aimed the headlamp as a whole (by means of the goniometer for example) in the corresponding opposite direction the light output in the following directions shall be controlled and lie within the required limits: passing-beam : Passing-beam: points HV B50L and 75 R (75 L (B50R and 75 L, respectively); driving-beam : Driving-beam: IM and point HV (percentage of IM).
8.changed
The discomfort caused by the passing-beam of headlamps shall be gauged9. This requirement will be the subject of a recommendation to administrations. C. Further administrative provisions
9.1.2.changed
Require a further test report from the Technical Service responsible for conducting the tests. 9 This requirement will be the subject of a recommendation to administrations.
10.6.deleted
10.1.changed
Headlamps approved under this Regulation shall be so manufactured as to conform to the type approved by meeting under this Regulation. The compliance with the requirements set forth in paragraphs 6. and 7. above shall be verified as follows: The minimum requirements for Conformity of Production (CoP) control procedures set forth in Annex 5 to this Regulation shall be complied with. The minimum requirements for sampling by an inspector set forth in Annex 7 to this Regulation shall be complied with.
10.7.deleted
10.2.changed
The minimum requirements for authority which has granted type approval may at any time verify the conformity control methods applied in each production facility. The normal frequency of production control procedures set forth in Annex 5 to this Regulation these verifications shall be complied with. once every two years.
10.3.changed
10.4.changed
The authority which has granted type approval may at any time verify the conformity control methods applied in each production facility. The normal frequency of these verifications shall be once every two years. reference mark is disregarded.
10.5.changed
14.1.changed
14.5.deleted
14.2.changed
14.3.changed
14.4.changed
Annex 1changed
(maximum format: A4 (210 x 297 mm)) issued by: Name of administration: concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of headlamp pursuant to UN Regulation No. 112 Approval No .…..…………………..…….. Extension No …………………………. Distinguishing number of the country which has granted/refused/withdrawn approval (see the provisions of the Regulation concerning approval). Strike out which does not apply.
9.changed
Brief description: 1 Distinguishing number of the country which has granted/refused/withdrawn approval (see the provisions of the Regulation concerning approval). 2 Strike out which does not apply. Annex 1 Number and specific identification code(s) of LED module(s) and for each LED module a statement whether it is replaceable or not: yes/no 2 Number and specific identification code(s) of electronic light source control gear(s) .. Total objective luminous flux as described in paragraph 5.9. exceeds 2,000 lumens: yes/no/does not apply2 The adjustment of the cut-off has been determined at: 10 m/25 m/does not apply2 The determination of the minimum sharpness of the "cut-off" has been carried out at: 10 m/25 m/does not apply2
16.changed
The list of documents deposited with the Type Approval Authority which has granted approval is annexed to this communication and may be obtained on request. _________________ Indicate the appropriate marking selected from the list below: C, C, C , R, R PL, CR, CR, CR , C/R, C/R, C/R , C/ , C/ , C/ , C, PL, C PL, C PL, CR PL, CR PL, CR PL, C/R PL, C/R PL, C/R PL, C/PL, C/PL, C/PL HC, HC, HC , HR, HR PL, HCR, HCR, HCR, HC/R, HC/R, HC/R, HC/, HC/, HC/ , HC PL, HC PL, HC PL, HCR PL, HCR PL, HCR PL, HC/R PL, HC/R PL, HC/R PL, HC/PL, HC/PL, HC/PL Annex 2
Annex 2added
Figure 6: Class B for both traffic systems. Figure 8: Class A in respect of the driving-beam only. Figure 10: Class B in respect to the passing-beam only and designed for right-hand traffic only.
The passing-beam shall not be operated simultaneously with the driving-beam and/or
another reciprocally incorporated headlamp.
Annex 2
Figure 1changed
a 8 mm (on glass) a 5 mm (on plastic material) The headlamp bearing one of the above approval marks has been approved in the Netherlands (E4) pursuant to UN Regulation No. 112 under approval number 243, meeting the requirements of this Regulation, as amended by the 01 series of amendments. amendments.1 The passing- beam passing-beam is designed for right-hand traffic only. The letters CR (Figure 1) indicate that it concerns a Class A passing and driving-beam and the letters HCR (Figure 2) indicate that it concerns a Class B passing and driving-beam. The figure 30 indicates that the maximum luminous intensity of the driving-beam is between 123,625 and 145,125 candelas. Note: The approval number and additional symbols shall be placed close to the circle and either above or below the letter "E", or to the right or left of that letter. The digits of the approval number shall be on the same side of the letter "E" and face in the same direction. The use of Roman numerals as approval numbers should be avoided so as to prevent any confusion with other symbols.
Figure 3added
1 The 02 series of amendments does not require changes in the approval number (TRANS/WP.29/815,
para. 82).
Annex 2
Figure 4bchanged
The headlamp bearing the above approval mark meets the requirements of this Regulation in respect of both the passing-beam and the driving-beam and is designed: Figures 4a and 4b: Class B for both traffic systems by means of an appropriate adjustment of the setting of the optical unit or the filament lamp light source on the vehicle.
Figure 8deleted
Figure 10deleted
Figure 9changed
Identification of a headlamp incorporating a lens of plastic material meeting the requirements of this Regulation: right-hand left-hand traffic only.
Figure 11changed
(The vertical and horizontal lines schematize the shape of the light-signalling device. They are not part of the approval mark). Note: The four examples above correspond to a lighting device bearing an approval mark comprising: A front position lamp approved in accordance with the 02 series of amendments to UN Regulation No. 7, A headlamp, Class B, with a passing-beam designed for right- and left-hand traffic and a driving-beam with a maximum intensity comprised between 123,625 and 145,125 candelas (as indicated by the number 30), approved in accordance with the requirements of this Regulation, as amended by the 01 series of amendments amendments1 and incorporating a lens of plastic material, A front fog lamp approved in accordance with the 02 series of amendments to UN Regulation No. 19 and incorporating a lens of plastic material, A front direction indicator lamp of category 1a approved in accordance with the 01 series of amendments to UN Regulation No. 6. Annex 2
Figure 12changed
Example 1 The above example corresponds to the marking of a lens of plastic material intended to be used in different types of headlamps, namely: Either A headlamp, Class B, with a passing-beam designed for both traffic systems and a driving-beam with a maximum luminous intensity comprised between 123,625 and 145,125 candelas (as indicated by the number 30), approved in Germany (E1) in accordance with the requirements of this Regulation, as amended by the 01 series of amendments, amendments,1 Which is reciprocally incorporated with A front position lamp approved in accordance with the 02 series of amendments to UN Regulation No. 7; or A headlamp, Class A, with a passing-beam designed for both traffic systems and a driving-beam with a maximum luminous intensity comprised between 48,375 cd and 64,500 cd (as indicated by the number 12.5), approved in Germany (E1) in accordance with the requirements of this Regulation, as amended by the 01 series of amendments, amendments,1 Which is reciprocally incorporated with: The same front position lamp as above; or Even either of the above-mentioned headlamps approved as a single lamp. The main body of the headlamp shall bear the only valid approval number, for instance: Example 2 The above example corresponds to the marking of a lens of plastic material used in a unit of two headlamps approved in France (E2) under approval number 81151, consisting of: A headlamp, Class B, emitting a passing-beam and a driving-beam with a maximum luminous intensity between x and y candelas, meeting the requirements of this Regulation, and Annex 2 A headlamp, Class B, emitting a driving-beam designed for both traffic systems with a maximum luminous intensity between w and z candelas, meeting the requirements of this Regulation, the maximum luminous intensities of the driving-beams as a whole being comprised between 123,625 and 145,125 candelas.
Figure 13changed
MD E3 17325 The LED module bearing the light source module identification code shown above has been approved together with a headlamp initially approved in Italy (E3) under approval number 17325. Annex 3
Annex 3changed
locations Figure A Spherical coordinate measuring system ECE projection screen at 25 meter distance E25m= l(h,v)x cos γ/r2 Annex 3 Figure B Passing-beam for right-hand traffic v 1 2 3 Zone III 4 5 6 B50L BR 7 8 hh 75L 75R h 25L Zone II 50L Zone IV 50 50R 25R V Zone I 1 deg 1 deg v Zone II is limited by line h-h, Zone I, Zone IV and vertical lines at 9 deg L and 9 deg R h-h = horizontal plane , v-v = vertical plane passing through the optical axis of the headlamp The test point locations for left-hand traffic are mirrored about the VV line line. Figure C Driving-beam test points Annex 4
Annex 4changed
in operation Tests on complete headlamps Once the photometric values have been measured according to the prescriptions of this Regulation, in the point for Imax I max for driving-beam and in points HV, 25L, 50 R, B 50 L for passing-beam (or HV, 25R, 50 L, B 50 R for headlamps designed for left-hand traffic) a complete headlamp sample shall be tested for stability of photometric performance in operation. "Complete headlamp" shall be understood to mean the complete lamp itself including those surrounding body parts and lamps which could influence its thermal dissipation. The tests shall be carried out: (a) In a dry and still atmosphere at an ambient temperature of 23 C ± 5 C, the test sample being mounted on a base representing the correct installation on the vehicle; (b) In case of replaceable light sources: using mass production filament light sources, which have been aged for at least one hour, or mass production gas-discharge light sources, which have been aged for at least 15 hours or mass production LED modules which have been aged for at least 48 hours and cooled down to ambient temperature before starting the tests as specified in this Regulation. The LED modules supplied by the applicant shall be used. The measuring equipment shall be equivalent to that used during headlamp type approval tests. The test sample shall be operated without being dismounted from or readjusted in relation to its test fixture. The light source used shall be a light source of the category specified for that headlamp.
1.1.1.changed
The headlamp shall be operated for a period according to the specified time, so that: For the test schedule see Annex 8 to this Regulation.
1.1.1.1.changed
(a) In the case where only one lighting function (driving or passing-beam or front fog lamp) is to be approved, the corresponding filament and/or LED module(s) is (are) lit for the prescribed time 2; (b) In the case of a headlamp with a passing-beam and one or more driving-beams or in the case of a headlamp with a passing-beam and a front fog lamp: 1 For the test schedule see Annex 8 to this Regulation. 2 When the tested headlamp includes signalling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing mode with an on/ off time of approximately one to one. (i) The headlamp shall be subjected to the following cycle until the time specified is reached: 15 minutes, principal passing-beam filament or principal passing-beam LED module(s) lit; 5 minutes, all filaments and/or LED module(s) lit. (ii) If the applicant declares that the headlamp is to be used with only the passing-beam lit or only the driving-beam(s) lit3 at a time, the test shall be carried out in accordance with this condition, activating2 successively the passing-beam half of the time and the driving-beam(s) (simultaneously) for half the time specified in paragraph 1.1. above. (c) In the case of a headlamp with a front fog lamp and one or more driving-beams: (i) The headlamp shall be subjected to the following cycle until the time specified is reached: 15 minutes, front fog lamp lit; 5 minutes, all filaments and/or all LED modules lit. (ii) If the applicant declares that the headlamp is to be used with only the front fog lamp lit or only the driving-beam(s) lit3 at a time, the test shall be carried out in accordance with this condition, activating2 successively the front fog lamp half of the time and the driving-beam(s) (simultaneously) for half the time specified in paragraph 1.1. above. (d) In the case of a headlamp with a passing-beam, one or more driving- beams and a front fog lamp: (i) The headlamp shall be subjected to the following cycle until the time specified is reached: 15 minutes, principal passing-beam filament or principal passing-beam LED module(s) lit; 5 minutes, all filaments and/or all LED modules lit. When the tested headlamp includes signalling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing mode with an on/ off time of approximately one to one. Should two or more lamp filaments and/or LED module(s) be simultaneously lit when headlamp flashing is used, this shall not be considered as being normal use of the filaments and/or LED module(s). Annex 4 (ii) If the applicant declares that the headlamp is to be used with only the passing-beam lit or only the driving-beam(s)3 lit at a time, the test shall be carried out in accordance with this condition, activating2 successively the principal passing-beam half of the time and the driving-beam(s) for half the time specified in paragraph 1.1. above, while the front fog lamp is subjected to a cycle of 15 minutes off and 5 minutes lit for half of the time and during the operation of the driving-beam; (iii) If the applicant declares that the headlamp is to be used with only the passing-beam lit or only the front fog lamp3 lit at a time, the test shall be carried out in accordance with this condition, activating2 successively the principal passing-beam half of the time and the front fog lamp for half of the time specified in paragraph 1.1. above, while the driving-beam(s) is(are) subjected to a cycle of 15 minutes off and 5 minutes lit 3 Should two or more filament light sources and/or LED module(s) be simultaneously lit when headlamp flashing is used, this shall not be considered as being normal use of the filament light sources and/or LED module(s). Annex 4 for half of the time and during the operation of the principal passing-beam; (iv) If the applicant declares that the headlamp is to be used with only the passing-beam lit or only the driving-beam(s)3 lit or only the front fog lamp3 lit at a time, the test shall be carried out in accordance with this condition, activating2 successively the principal passing-beam one third of the time, the driving- beam(s) one third of the time and the front fog lamp for one third of the time specified in paragraph 1.1. above. (e) In the case of a passing-beam designed to provide bend lighting with the addition of a filament light source and/or one or more LED module(s), this light source and/or LED module(s) shall be switched on for one minute, and switched off for nine minutes during the activation of the passing-beam only (see Annex 4 – Appendix 1).
1.1.2.2.changed
To comply with the requirements of this Regulation, the photometric values shall be verified in the following points: Passing-beam: 50 R - B 50 L - HV – 25 L for headlamps designed for right-hand traffic, traffic 50 L - B 50 R - HV – 25 R for headlamps designed for left-hand traffic. Driving-beam: traffic Driving beam: Point Imax I max Another aiming may be carried out to allow for any deformation of the headlamp base due to heat (the change of the position of the cut-off line is covered in paragraph 2. of this annex). A Except for point B 50 L, a 10 per cent discrepancy between the photometric characteristics and the values measured prior to the test is permissible including the tolerances of the photometric procedure. The value measured at point B 50 L shall not exceed the photometric value measured prior to the test by more than 170 cd.
1.2.changed
After being tested as specified in paragraph 1.1. above, the headlamp shall be operated for one hour as described in paragraph 1.1.1., after being prepared as prescribed in paragraph 1.2.1., and checked as prescribed in paragraph 1.1.2. Annex 4
1.2.1.1.1.changed
For headlamp with the outside lens in glass: The mixture of water and a polluting agent to be applied to the headlamp shall be composed of: (a) 9 parts by weight of silica sand with a particle size of 0-100 µm, μm, (b) 1 part by weight of vegetal carbon dust (beechwood) produced from beech wood with a particle size of 0-100 µm, μm, (c) 0.2 parts by weight of NaCMC4, NaCMC,4 and An (d) 5 parts by weight of sodium chloride (pure at 99 per cent), (e) an appropriate quantity of distilled water, with a conductivity of 1 mS/m. µS/m. The mixture must shall not be more than 14 days old.
1.2.1.1.2.changed
For headlamp with the outside lens in plastic material: The mixture of water and polluting agent to be applied to the headlamp shall be composed of: (a) 9 parts by weight of silica sand with a particle size of 0-100 µm, μm; 4 NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall have a degree of substitution (DS) of 0.6-0.7 and a viscosity of 200-300 cP for a 2 per cent solution at 20° C. Annex 4 (b) 1 part by weight of vegetal carbon dust (beechwood) produced from beech wood with a particle size of 0-100 µm, μm; (c) 0.2 part by weight of NaCMC4, NaCMC;4 (d) 5 parts by weight of sodium chloride (pure at 99 per cent); (e) 13 parts by weight of distilled water with a conductivity of 1 mS/m, and mS/m; (f) 2 ± 1 parts by weight drops of surface-actant5 surfactant.5 The mixture must shall not be more than 14 days old.
1.2.1.2.changed
The test mixture shall be uniformly applied to the entire light-emitting surface of the headlamp and then left to dry. This procedure shall be repeated until the illumination value has dropped to 15-20 per cent of the values measured for each following point under the conditions described in this annex: Point of Emax in passing-beam/driving-beam and in driving-beam only, 50 R and 50 V6 for a headlamp producing only a passing-beam, designed for right-hand traffic, 50 L and 50 V6 for a headlamp producing only a passing-beam, designed for left-hand traffic. NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall have a degree of substitution (DS) of 0.6-0.7 and a viscosity of 200-300 cP for a 2 per cent solution at 20° C. The tolerance on quantity is due to the necessity of obtaining a dirt that correctly spreads out on all the plastic lens. Point 50 V is situated 375 mm below HV on the vertical line v-v on the screen at 25 m distance.
2.1.changed
The test shall be carried out in a dry and still atmosphere at an ambient temperature of 23 °C ± 5 °C. Using a mass production filament lamp light source or the LED module(s) as submitted with the headlamp, which has (have) been aged for at least one hour, the headlamp shall be operated on the principal passing-beam without being dismounted from or readjusted in relation to its test fixture. (For the purpose of this test, the voltage shall be adjusted as specified in paragraph 1.1.1.2.). The position of the cut-off line in its horizontal part (between vv and the vertical line passing through point B 50 L for right-hand traffic or B 50 R for left-hand traffic) shall be verified 3 minutes (r 3) (r3) and 60 minutes (r60) respectively after operation. The measurement of the variation in the cut-off line position as described above shall be carried out by any method giving acceptable accuracy and reproducible results.
2.2.1.changed
The result expressed in milliradians (mrad) shall be considered as acceptable for a passing-beam passing beam headlamp when the absolute value r1 = r3 – r60 5 The tolerance on quantity is due to the necessity of obtaining a dirt that correctly spreads out on all the plastic lens. 6 Point 50 V is situated 375 mm below HV on the vertical line v-v on the screen at 25 m distance. recorded on the headlamp is not more than 1.0 mrad ( r1 1.0 mrad) upward and not more than 2.0 mrad ( r1 2.0 mrad) downwards.
2.2.2.changed
However, if this value is: Movement more than 1.0 mrad but not more than upward 1.5 mrad Upward (1.0 mrad < ΔrI < 1.5 mrad) more than 2.0 mrad but not more than downward 3.0 mrad Downward (2.0 mrad < ΔrI < 3.0 mrad) a A further sample of a headlamp mounted on a test fixture representative of the correct installation on the vehicle shall be tested as described in paragraph 2.1. after being subjected three consecutive times to the cycle as described below, in order to stabilize the position of mechanical parts of the headlamp on a base representative of the correct installation on the vehicle: Operation of the passing-beam for one hour, (the voltage shall be adjusted as specified in paragraph 1.1.1.2.), After this period of one hour, the headlamp type shall be considered as acceptable if the absolute value Δr measured on this sample meets the requirements in paragraph 2.2.1. above. Annex 4 – Appendix 1
2.1.added
above after being subjected three consecutive times to the cycle as
described below, in order to stabilize the position of mechanical parts of the
headlamp:
(a) Operation of the passing beam for one hour (the voltage shall be
adjusted as specified in paragraph 1.1.1.2.);
(b) One hour period with the lamp switched off.
After these three cycles, the headlamp type shall be considered as acceptable
if the absolute values Δr measured according to paragraph 2.1. above on this
further sample meet the requirements in paragraph 2.2.1. above.
Annex 4 – Appendix 1
1.2.changed
With respect to photometric performances, the conformity of mass-produced headlamps shall not be contested if, when testing photometric performances of any headlamp chosen at random and equipped with a standard (étalon) filament lamp light source and/or LED module(s), as present in the lamp:
1.2.2.1.changed
For the passing-beam, the values prescribed in this Regulation are met at HV (with a tolerance of +170 cd) and related to that aiming at least one point within a circle of 0.35 degrees around points B 50 L (or R) (with a tolerance of 85 cd), 75 R (or L), 50 V, 25 R, 25 L, and in the entire area of zone IV which is not more than 0.52 degrees above line 25 R and 25 L;
1.2.2.2.changed
And if, for the driving-beam, HV being situated within the isolux 0.75 I max Imax a tolerance of +20 per cent for maximum values and -20 per cent for minimum values is observed for the photometric values at any measuring point specified in paragraph 6.3.2. of this Regulation.
1.2.4.changed
If in the case of a lamp equipped with a replaceable filament light source the results of the tests described above do not meet the requirements, tests shall be repeated using another standard (étalon) filament lamp. light source.
1.3.changed
With respect to the verification of the change in vertical position of the cut- off line under the influence of heat, the following procedure shall be applied: Letters in brackets refer to headlamps intended for right-hand traffic. Annex 5 One of the sampled headlamps shall be tested according to the procedure described in paragraph 2.1. of Annex 4 after being subjected three consecutive times to the cycle described in paragraph 2.2.2. of Annex 4. The headlamp shall be considered as acceptable if r does not exceed 1.5 mrad. 1 Letters in brackets refer to headlamps intended for right-hand traffic. Annex 5 If this value exceeds 1.5 mrad but is not more than 2.0 mrad, a second sample shall be subjected to the test after which the mean of the absolute values recorded on both samples shall not exceed 1.5 mrad.
2.4.changed
The sampled headlamps shall be subjected to photometric measurements at the points provided for in the Regulation, the reading being limited at the points Imax, HV2, HV1, HL, HR3 HR2 in the case of a driving-beam, and to points B 50 L (or R), HV, 50L (or R), 50 V, 75 R (or L) and 25 L (or R) in the case of the passing-beam (see figure in Annex 3).
2.5.changed
The manufacturer is responsible for carrying out a statistical study of the test results and for defining, in agreement with the Competent Authority, criteria governing acceptability of his products in order to meet the specification laid down for verification of conformity of products in paragraph 10.1. of this Regulation. The criteria governing acceptability shall be such that, with a confidence level of 95 per cent, the minimum probability of passing a spot check in accordance with Annex 7 (first sampling) would be 0.95. When the driving-beam is reciprocally incorporated with the passing-beam, HV in the case of the driving-beam shall be the same measuring point as in the case of the passing-beam. HL and HR: points "hh" located at 2.5 degrees to the left and to the right of point HV respectively. Annex 6
2.2.2.2.changed
Soak a piece of cotton cloth (as per ISO 105) until saturation with the mixture defined in paragraph 2.2.2.1. above and, within 10 seconds, apply it for 10 minutes to the outer face of the sample at a pressure of 50 N/cm2, corresponding to an effort of 100 N applied on a test surface of 14 x 14 mm. Annex 6 During this 10-minute period, the cloth pad shall be soaked again with the mixture so that the composition of the liquid applied is continuously identical with that of the test mixture prescribed. Annex 6 During the period of application, it is permissible to compensate the pressure applied to the sample in order to prevent it from causing cracks.
2.2.3.1.changed
After the test of resistance to atmospheric agents, the outer face of the samples shall be free from cracks, scratches, chipping and deformation, and T2 − T3 the mean variation in transmission Δt = , measured on the three T2 samples according to the procedure described in Appendix 2 to this annex shall not exceed 0.020 (tm < 0.020).
2.2.3.2.changed
After the test of resistance to chemical agents, the samples shall not bear any traces of chemical staining likely to cause a variation of flux diffusion, whose T5 − T4 mean variation Δd = , measured on the three samples according to T2 the procedure described in Appendix 2 to this annex shall not exceed 0.020 (dm < 0.020).
2.3.3.changed
After the above two tests have been performed successively, the mean value of the variation in transmission Δt = T2 − T3 , measured on the three samples T2 according to The procedure described in Appendix 2 to this annex shall not exceed 0.010 (Δtm < 0.010).
2.4.2.changed
After this test, the variations: T2 − T3 in transmission: Δt = , T2 T5 − T4 and in diffusion: Δt = , T2 shall be measured according to the procedure described in Appendix 2 in the area specified in paragraph 2.2.4.1.1. of this Regulation. The mean value of the three samples shall be such that: Δtm < 0.100; Δdm < 0.050.
2.5.2.changed
Use an adhesive tape with a force adhesion of 2 N/(cm of width) 20 per cent measured under the standardized conditions specified in Appendix 4 to this annex. This adhesive tape, which shall be at least 25 mm wide, shall be pressed for at least five minutes to the surface prepared as prescribed in paragraph 2.5.1. above. Annex 6 Then the end of the adhesive tape shall be loaded in such a way that the force of adhesion to the surface considered is balanced by a force perpendicular to that surface. At this stage, the tape shall be torn off at a constant speed of 1.5 m/s ± 0.2 m/s.
2.6.1.added
Annex 6
2.6.1.2.changed
After the test, the results of photometric measurements carried out on the headlamp in accordance with this Regulation shall not exceed by exceed: (a) By more than 30 per cent the maximum values prescribed at points B 50 L and HV and not be by more than 10 per cent below the minimum values prescribed at point 75 R (in the case of headlamps intended for left-hand left- hand traffic, the points to be considered are B 50 R, HV R and 75 L). L); or (b) By more than 10 per cent below the minimum values prescribed for HV in the case of a headlamp producing driving-beam only.
2.3.1.deleted
3.1.1.changed
After the test for resistance to chemical agents and the test for resistance to detergents and hydrocarbons, the outer face of the samples exhibits no cracks, chipping or deformation visible to the naked eye (see paras. 2.2.2., 2.3.1. and
2.3.2.added
above);
1.changed
The beam of a collimator K with a half divergence β/2 = 17.4 x 104 10 4 rd is limited by a diaphragm Dτ with an opening of 6 mm against which the sample stand is placed. A convergent achromatic lens L2, corrected for spherical aberrations links the diaphragm Dτ with the receiver R; the diameter of the lens L2 shall be such that it does not diaphragm the light diffused by the sample in a cone with a half top angle of β/2 = 14°. An annular diaphragm DD, with angles αo/2 = 1° and αmax /2 = 12° is placed in an image focal plane of the lens L2. The non-transparent central part of the diaphragm is necessary in order to eliminate the light arriving directly from the light source. It shall be possible to remove the central part of the diaphragm from the light beam in such a manner that it returns exactly to its original position. The distance L2 Dτ and the focal length F21 of the lens L2 shall be so chosen that the image of Dτ completely covers the receiver R. When the initial incident flux is referred to 1,000 units, the absolute precision of each reading shall be better than 1 unit.
2.changed
The following readings shall be taken: Reading With sample With central Quantity represented part of DD T1 No No Incident flux in initial reading T2 Yes No Flux transmitted by the new material in a field (before test) of 24° T3 Yes No Flux transmitted by the tested material in a field (after test) of 24° T4 Yes Yes Flux diffused by the new material (before test) T5 Yes Yes Flux diffused by the tested material (after test) 1 For L2 it is recommended to use a focal distance of about 80 mm. Annex 6 – Appendix 3
1.2.changed
The test mixture shall be composed of: (a) Silica sand of hardness 7 on the Mohr scale, with a grain size between 0 and 0.2 mm and an almost normal distribution, with an angular factor of 1.8 to 2; (b) Water of hardness not exceeding 205 g/m3 g/m 3 for a mixture comprising 25 g of sand per litre of water.
2.changed
The outer surface of the lamp lenses shall be subjected once or more than once to the action of the sand jet produced as described above. The jet shall be sprayed almost perpendicular to the surface to be tested. The deterioration shall be checked by means of one or more samples of glass placed as a reference near the lenses to be tested. The mixture shall be sprayed until the variation in the diffusion of light on the sample or samples measured by the method described in Appendix 2, is such that: T5 − T4 d = = 0.0250 0.0025 T2 Several reference samples may be used to check that the whole surface to be tested has deteriorated homogeneously.
6.changed
The five values obtained shall be arranged in order and the median value taken as a result of the measurement. This value shall be expressed in Newtons per centimetre of width of the tape. Annex 7 8
1.2.changed
With respect to photometric performances, the conformity of mass-produced headlamps shall not be contested if, when testing photometric performances of any headlamp chosen at random and equipped with a standard filament lamp light source and/or LED module(s) present in the headlamp:
1.2.1.changed
No measured value deviates unfavourably by more than 20 per cent from the value prescribed in this Regulation. For values B 50 L (or R) 1 R)1 and zone III, the maximum unfavourable deviation may be respectively: B 50 L (or R): 170 cd equivalent 20 per cent 255 cd equivalent 30 per cent Zone III 255 cd equivalent 20 per cent 380 cd equivalent 30 per cent"
1.2.2.1.changed
For the passing-beam, the values prescribed in this Regulation are met at HV (with a tolerance of +170 cd) and related to that aiming at least one point of each area delimited on the measuring screen (at 25 m) by a circle 15 cm in radius around points B 50 L (or R)1 R) 1 (with a tolerance of 85 cd), 75 R (or L), 50 V, 25 R, 25 L, and in the entire area of zone IV which is not more than 22.5 cm above line 25 R and 25 L;
1.2.3.changed
If the results of the test described above do not meet the requirements, the alignment of the headlamp may be changed, provided that the axis of the beam is not displaced laterally by more than 1° to the right or left. Letters in brackets refer to headlamps intended for right-hand traffic.
1.2.4.changed
If the results of the tests described above do not meet the requirements, tests shall be repeated using another standard filament lamp light source and/or LED module(s) present in the headlamp.
2.1.1.deleted
1.3.changed
If, however, vertical adjustment cannot be performed repeatedly to the required position within the tolerances described in paragraph 6.2.2.3. of this Regulation, one sample shall be tested according to the procedure described in paragraphs 2. and 3. of Annex 9. 1 Letters in brackets refer to headlamps intended for right-hand traffic.
2.1.1.1.deleted
2.1.1.2.deleted
2.1.added
The conformity of mass-produced headlamps shall not be contested if the
deviation of any specimen of samples A and B (all four lamps) is not
more than 20 per cent.
In the case, that the deviation of both lamps of sample A is not more than
0 per cent, the measurement can be closed.
2.1.2.deleted
2.2.added
The conformity of mass-produced headlamps shall be contested if the
deviation of at least one specimen of samples A or B is more than 20 per
cent.
The manufacturer shall be requested to bring his production in line with
the requirements (alignment) and a repeated sampling according to
paragraph 3. below shall be carried out within two months' time after the
notification. The samples A and B shall be retained by the Technical
Service until the entire CoP process is finished.
3.changed
2.2.1.deleted
3.1.added
The conformity of mass-produced headlamps shall not be contested if the
deviation of any specimen of samples C and D (all four lamps) is not
more than 20 per cent.
In the case, that the deviation of both lamps of sample C is not more than
0 per cent, the measurement can be closed.
2.2.1.1.deleted
3.2.added
The conformity of mass-produced headlamps shall be contested if the
deviation of at least:
2.2.1.2.deleted
3.2.1.changed
2.2.2.deleted
3.2.2.added
One specimen of samples C and D is more than 30 per cent.
In this case the approval shall be withdrawn and paragraph 5. below shall
be applied.
2.3.deleted
4.changed
2.3.1.deleted
4.1.added
The conformity of mass-produced headlamps shall not be contested if the
deviation of any specimen of samples E and F (all four lamps) is not more
than 20 per cent.
In the case, that the deviation of both lamps of sample E is not more than
0 per cent, the measurement can be closed.
Annex 8
2.3.2.deleted
4.2.added
The conformity of mass-produced headlamps shall be contested if the
deviation of at least one specimen of samples E or F is more than 20 per
cent.
In this case the approval shall be withdrawn and paragraph 5. below shall
be applied.
2.3.3.deleted
5.added
Approval shall be withdrawn according to paragraph 11. of this
Regulation.
6.added
With respect to the verification of the change in vertical positions of the
cut-off line under the influence of heat, the following procedure shall be
applied:
One of the headlamps of sample A shall be tested according to the
procedure described in paragraph 2.1. of Annex 4 after being subjected
three consecutive times to the cycle described in paragraph 2.2.2. of
Annex 4.
The headlamp shall be considered as acceptable if r does not exceed
1.5 mrad upwards and does not exceed 2.5 mrad downwards.
If this value exceeds 1.5 mrad but is not more than 2.0 mrad upwards or
exceeds 2.5 mrad but is not more than 3.0 mrad downwards, the second
headlamp of sample A shall be subjected to the test after which the mean
of the absolute values recorded in both samples shall not exceed 1.5 mrad
upwards and shall not exceed 2.5 mrad downwards.
However, if this value of 1.5 mrad upwards and 2.5 mrad downwards on
sample A is not complied with, the two headlamps of sample B shall be
subjected to the same procedure and the value of r for each of them shall
not exceed 1.5 mrad upwards and shall not exceed 2.5 mrad downwards.
3.1.1.deleted
3.1.1.1.deleted
3.1.1.2.deleted
3.1.2.deleted
6.changed
0 6 12 h Annex 8 D F
3.2.1.1.deleted
3.2.1.2.deleted
3.3.deleted
3.3.1.deleted
3.3.2.deleted
11.changed
0 4 8 12 h Annex 9
3.3.3.deleted
Figure 1deleted
2.3.changed
The part of the horizontal "cut-off" that serves for vertical adjustment shall be horizontal between 1.5° and 3.5° from the V-V line (see Figure 1). This paragraph should be amended when an objective test method is available. The inflection points of the "cut-off" gradient at the vertical lines at 1.5°, 2.5° and 3.5° shall be determined by the equation: The maximum vertical distance between the inflection points determined shall not exceed 0.2°. 1 This paragraph should be amended when an objective test method is available. Annex 9 (d2 (log E) / dβ2 = 0).
3.2.changed
The applicant shall specify one of the following horizontal aim methods: (a) The "0.2 D line" method (see Figure 2 below). A single horizontal line at 0.2° D shall be scanned from 5° left to 5° right after the lamp has been aimed vertically. The maximum gradient "G" determined using the formula G = (log Eβ - log E(β + 0.1°)) where β is the horizontal position in degrees, shall not be less than 0.08. Annex 9 The inflection point found on the 0.2 D line shall be positioned on the line A.
Figure 2changed
Note: The scales are different for vertical and horizontal lines. (b) The "3 line" method (see Figure 3) Three vertical lines shall be scanned from 2° D to 2° U at 1°R, 2°R, and 3°R after the lamp has been aimed vertically. The respective maximum gradients "G" determined using the formula: G = (log Eβ – log E(β + 0.1°)) where β is the vertical position in degrees, shall not be less than 0.08. The inflection points found on the three lines shall be used to derive a straight line. The intersection of this line and the line B found while performing vertical aim shall be placed on the V line. Annex 9
Figure 3changed
Note: The scales are different for vertical and horizontal lines. Annex 10
3.1.2.changed
The kind of light sources on a LED module shall be light-emitting diodes (LED) as defined in UN Regulation No. 48 paragraph 2.7.1. in particular with regard to the element of visible radiation. Other kinds of light sources are not permitted.
3.2.1.changed
All samples shall be tested under the conditions as specified in paragraphs 6.1.4. and 6.1.5. of this Regulation. If not specified differently in this annex LED modules shall be tested inside the headlamp as submitted by the manufacturer. Annex 10
4.1.1.changed
In addition to measurements as described in paragraph 7. of this Regulation: The minimum red content of the light of a LED module or headlamp incorporating LED module(s) tested at 50 V shall be such that: 780 nm E () V() d e = 610 nm e k red = 780 nm 0.05 E () V() d =380 nm e 380 nm where: Ee() (unit: W) is the spectral distribution of the irradiance; V() (unit: 1) is the spectral luminous efficiency; () (unit: nm) is the wavelength. This value shall be calculated using intervals of one nanometre.
4.2.changed
The UV-radiation of a low-UV-type LED module shall be such that: 400 nm E ( ) S ( ( ) d = 250nm e k UV = 780 nm 10 5 −5 W / lm km E ( ) V ( ) d = 380nm e where: S() (unit: 1) is the spectral weighting function; km = 683 lm/W is the maximum value of the luminous efficacy of radiation. (For definitions of the other symbols see paragraph 4.1.1. above). This value shall be calculated using intervals of one nanometre. The UV-radiation shall be weighted according to the values as indicated in the Table UV below: Annex 10 Table UV Values according to "IRPA/INIRC Guidelines on limits of exposure to ultraviolet radiation". Wavelengths (in nanometres) chosen are representative; other values should be interpolated. S() S() S() 250 0.430 305 0.060 355 0.000 16 255 0.520 310 0.015 360 0.000 13 260 0.650 315 0.003 365 0.000 11 265 0.810 320 0.001 370 0.000 09 270 1.000 325 0.000 50 375 0.000 077 275 0.960 330 0.000 41 380 0.000 064 280 0.880 335 0.000 34 385 0.000 053 285 0.770 340 0.000 28 390 0.000 044 290 0.640 345 0.000 24 395 0.000 036 295 0.540 350 0.000 20 400 0.000 030 300 0.300
4.3.1.1.changed
A photometric measurement of the headlamp shall be made after 1 minute of operation for the specific function at the test point specified below. For these measurements, the aim can be approximate but must be maintained for before and after ratio measurements. Test points to be measured: Passing-beam 50 V 25 R Driving-beam H – V HV
4.3.1.4.changed
Once stability of photometry has been achieved, apply the ratio calculated above to each of the remainder of the test points to create a new photometric table that describes the complete photometry based on one minute of operation. Annex 10
5.2.changed
Annex 11changed
contributors and correlated light source options Principal passing- Bend lighting: beam: passing-beam: UN Regulation No. 37 Bend lighting: light source or UN Regulation No. 37 LED module(s) light source or IR emitter: lamp or LED module(s) UN Regulation No. 37 lamp light sorce or LED module(s) LED module(s) lamp or LED module(s)