Compare versions of UN R134
Motor vehicles and their components with regard to the safety-related performance of hydrogen-fuelled vehicles (HFCV)
2.8.changed
"Exhaust point of discharge" means the geometric centre of the area where fuel cell purged gas is discharged from the vehicle. This Regulation does not cover the electrical safety of electric power train, the material compatibility and hydrogen embrittlement of the vehicle fuel system, and the post crash fuel system integrity in the event of full width frontal impact and rear impact. As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.3, para. 2. - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
2.10.changed
"Fuelling receptacle" means the equipment to which a fuelling station nozzle attaches to the vehicle and through which fuel is transferred to the vehicle. The fuelling receptacle is used as an alternative to a fuelling port. 1 This Regulation does not cover the electrical safety of electric power train, the material compatibility and hydrogen embrittlement of the vehicle fuel system, and the post crash fuel system integrity in the event of full width frontal impact and rear impact. 2 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.7, para. 2. - https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
4.2.changed
An approval number shall be assigned to each type approved approved: its first two digits (00 for the Regulation in accordance with Schedule 4 its initial form) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the Agreement (E/ECE/TRANS/505/Rev.3). approval. The same Contracting Party shall not assign the same number to another vehicle or component type.
4.6.3.changed
In the case of a specific component, the approval mark shall be placed on the specific component. 3 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev. 7, Annex 3 - https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutionsl
5.changed
Part I – Specifications of the compressed hydrogen storage system This part specifies the requirements for the compressed hydrogen storage system. The hydrogen storage system consists of the high pressure storage container and primary closure devices for openings into the high pressure storage container. Figure 1 shows a typical compressed hydrogen storage system consisting of a pressurized container, three closure devices and their fittings. The closure devices shall include the following functions, which may be combined: (a) TPRD; (b) Check valve that prevents reverse flow to the fill line; and (c) Automatic shut-off valve that can close to prevent flow from the container to the fuel cell or internal combustion engine. Any shut-off valve, and TPRD that form the primary closure of flow from the storage container shall be mounted directly on or within each container. At least one component with a check valve function shall be mounted directly on or within each container. The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev. 3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
5.1.1.changed
Three (3) containers shall be hydraulically pressurized until burst (Annex 3, paragraph 2.1. test procedure). burst. The manufacturer shall supply documentation (measurements and statistical analyses) that establish the midpoint burst pressure of new storage containers, BPO. All containers tested shall have a burst pressure within ±10 per cent of BP O BPO and greater than or equal to a minimum BPmin of 225 per cent NWP. In addition, containers having glass-fibre composite as a primary constituent to have a minimum burst pressure greater than 350 per cent NWP." NWP.
5.1.2.changed
5.2.changed
If all three pressure cycle life measurements made in paragraph 5.1.2. are greater than 11,000 cycles, or if they are all within ± 25 per cent of each other, then only one (1) container is tested in paragraph 5.2. Otherwise, three (3) containers are tested in paragraph 5.2. A hydrogen storage container shall not leak during the following sequence of tests, which are applied in series to a single system and which are illustrated in Figure 2. Specifics of applicable test procedures for the hydrogen storage system are provided in Annex 3, paragraph 3. Verification test for performance durability (hydraulic) BPO <20% burst 180%NWP Pressure → (4 min) chemical exposure 150% NWP 125%NWP Chemicals 80%NWP time Proof Pressure Damage Drop 60% #Cycles 1000 hr 15C-25C 10 +85C 20% #Cycles 48 hr cycles +85C, 95%RH 15-25C 20% #Cycles -40C Residual Strength
Figure 2added
BPO
<20%
burst
180%NWP
Pressure
(4 min)
chemical
exposure 150% NWP
Chemicals 125%NWP
80%NWP
time
Proof Pressure
Damage
Drop
60% #Cycles 1000 hr
15C-25C 10 +85C 20% #Cycles
48 hr cycles +85C, 95%RH
15-25C 20% #Cycles
-40C
Residual
Strength
5.2.2.changed
The storage container is dropped at several impact angles (Annex 3, paragraph 3.2. test procedure).
5.2.3.changed
The storage container is subjected to surface damage (Annex 3, paragraph 3.3. test procedure).
3.2.deleted
3.3.added
test procedure).
Figure 3changed
BPO <20% Burst 180%NWP 4 min Pressure → 125%NWP 115%NWP 80%NWP time a b c b a 150% +55oC +55oC NWP Leak / Permeation Leak / Permeation Proof Pressure 5% cy -40Ca 5% cy +50C 5% cy +50Cb 5% cy -40C > 30 hrs > 30 hrs 40%cy 15-25Cc 40%cy 15-25C a Fuel/defuel cycles @-40 o C with initial system equilibration @ -40 o C, 5 cycles with +20 o C fuel; 5 cycles with <-35 o C fuel b Fuel/defuel cycles @+50 o C with initial system equilibration @+50 o C, 5 cycles with <-35 o C fuel c Fuel/defuel cycles @15-25 o C with service (maintenance) defuel rate, 50 cycles
6.1.changed
TPRDs shall meet the following performance requirements: (a) Pressure cycling test (Annex 4, paragraph 1.1.); (b) (c) Accelerated life test (Annex 4, paragraph 1.2.); (c) (d) Temperature cycling test (Annex 4, paragraph 1.3.); (d) (e) Salt corrosion resistance test (Annex 4, paragraph 1.4.); (e) (f) Vehicle environment test (Annex 4, paragraph 1.5.); (f) (g) Stress corrosion cracking test (Annex 4, paragraph 1.6.); (g) (h) Drop and vibration test (Annex 4, paragraph 1.7.); (h) (i) Leak test (Annex 4, paragraph 1.8.); (i) (j) Bench top activation test (Annex 4, paragraph 1.9.); (j) (k) Flow rate test (Annex 4, paragraph 1.10.).
7.1.1.2.changed
Fuelling receptacle label: A label shall be affixed close to the fuelling receptacle; for instance inside a refilling hatch, showing the following information: fuel type (e.g. "CHG" for gaseous hydrogen), MFP, NWP, date of removal from service of containers.
7.2.changed
The vehicle fuel system shall comply with the following requirements after the vehicle crash tests in accordance with the following Regulations by also applying the test procedures prescribed in Annex 5 of this Regulation. (a) Frontal impact test in accordance with either Regulation No. 12, or Regulation No. 94; and (b) Lateral impact test in accordance with Regulation No. 95. In case that one or both of the vehicle crash tests specified above are not applicable to the vehicle, the vehicle fuel system shall, instead, be subject to the relevant alternative accelerations specified below and the hydrogen storage system shall be installed in a position satisfying the requirements in paragraph 7.2.4. The accelerations shall be measured at the location where the hydrogen storage system is installed. The vehicle fuel system shall be mounted and fixed on the representative part of the vehicle. The mass used shall be representative for a fully equipped and filled container or container assembly. Accelerations for vehicles of categories M1 and N1: (a) 20 g in the direction of travel (forward and rearward direction); (b) 8 g horizontally perpendicular to the direction of travel (to left and right). Accelerations for vehicles of categories M2 and N2: (a) 10 g in the direction of travel (forward and rearward direction); (b) 5 g horizontally perpendicular to the direction of travel (to left and right). Accelerations for vehicles of categories M3 and N3: (a) 6.6 g in the direction of travel (forward and rearward direction); (b) 5 g horizontally perpendicular to the direction of travel (to left and right).
7.1.7.deleted
7.2.4.deleted
7.2.4.2.added
Requirements on installation of the hydrogen storage system not subject to
the lateral impact test:
The container shall be mounted in a position which is between the two
vertical planes parallel to the centre line of the vehicle located 200 mm inside
from the both outermost edge of the vehicle in the proximity of its
container(s).
7.2.4.2.deleted
9.3.1.changed
Every container shall be tested in accordance with paragraph 5.2.1. of this Regulation. The test pressure is 150 per cent of NWP
9.3.2.changed
In any case, for each batch, which is not permitted to exceed 200 finished cylinders or liners (not including destructive test cylinders or liners), or one shift of successive production, whichever is greater, at least one container shall be subjected to the rupture test in paragraph 9.3.2.1. and furthermore at least one container shall be subjected to the pressure cycle test in paragraph 9.3.2.2.
9.3.2.1.changed
The test shall be performed according to paragraph 2.1. (hydrostatic pressure rupture test) of Annex 3. The required rupture pressure shall be at least BPmin BP O- 10 per cent, and in no case less than the average burst pressure recorded of value necessary to meet the last ten tests shall be at or above BPO-10 per cent. stress ratio requirements.
9.3.2.2.added
The test shall be performed according to paragraph 2.2. (hydrostatic pressure
cycling test) of Annex 3. The cylinder shall be pressure cycled using
hydrostatic pressures up to 125 per cent of NWP (+2/-0 MPa), to 22,000
cycles in case of no leakage or until leakage occurs. The relative humidity
shall not be specified. For the service life of 15 years, the cylinder shall not
leak or rupture within the first 11,000 cycles.
9.3.2.2.deleted
9.3.2.3.5.changed
Should any cylinder tested at the sampling frequency in paragraph 9.3.2.3.2. or 9.3.2.3.3. above fail to meet the required number of pressure cycles, then it shall be necessary to repeat the pressure cycling test at the sampling frequency in paragraph 9.3.2.3.1 above for a minimum 10 production batches. The sampling frequency for testing thereafter shall be that specified in paragraph 9.3.2.3.2. or 9.3.2.3.3. above.
9.3.2.3.2.changed
or 9.3.2.3.3. above. above fail to meet the minimum requirement regarding the number of pressure cycles (11,000 cycles), then the cause of failure shall be determined and corrected following the procedures in paragraph 9.3.2.3.7. The pressure cycling test shall then be repeated on an additional three cylinders from that batch. Should any of the three additional cylinders fail to meet the minimum requirement regarding the number of pressure cycles (11,000 cycles), then all cylinders of this batch shall be rejected.
9.3.2.3.2.deleted
12.changed
Names and addresses of Technical Services responsible for conducting approval tests and of the Type Approval Authorities The Contracting Parties to the Agreement applying this Regulation shall communicate to the United Nations secretariat the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval are to be sent. Annex 1 – Part 1 Annex 1 - Part 1 Model - I Information document No. … on the type approval of a hydrogen storage system with regard to the safety-related performance of hydrogen-fuelled vehicles The following information, if applicable, shall include a list of contents. Any drawings shall be supplied in appropriate scale and in sufficient detail on size A4 or on a folder of A4 format. Photographs, if any, shall show sufficient details. If the systems or components have electronic controls, information concerning their performance shall be supplied.
13.1.deleted
13.2.deleted
3.9.2.6.added
Delete where not applicable (there are cases where nothing needs to be deleted when more than one
entry is applicable).
Annex 1 – Part 1
13.3.deleted
13.4.deleted
13.5.deleted
13.6.deleted
3.9.5.4.changed
Nominal working pressure(s) and if downstream of the first pressure regulator, maximum allowable working pressure(s): MPa Annex 1 – Part 1 Annex 1 - Part 1 Model - II Information document No. … on the type approval of specific component for a hydrogen storage system with regard to the safety-related performance of hydrogen-fuelled vehicles The following information, if applicable, shall include a list of contents. Any drawings shall be supplied in appropriate scale and in sufficient detail on size A4 or on a folder of A4 format. Photographs, if any, shall show sufficient details. If the components have electronic controls, information concerning their performance shall be supplied.
3.9.3.deleted
3.9.4.3.added
Annex 1 – Part 1
3.9.5.4.changed
Nominal working pressure(s) and if downstream of the first pressure regulator, maximum allowable working pressure(s): MPa: Annex 1 – Part 1 Annex 1 - Part 1 Model - III Information document No. … on the type approval of a vehicle with regard to the safety-related performance of hydrogen-fuelled vehicles The following information, if applicable, shall include a list of contents. Any drawings shall be supplied in appropriate scale and in sufficient detail on size A4 or on a folder of A4 format. Photographs, if any, shall show sufficient details. If the systems or components have electronic controls, information concerning their performance shall be supplied.
3.9.changed
3.9.8.changed
Drawings showing requirements for installation and operation. 3 Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable). Annex 1 – Part 2 Annex 1 - Part 2 Model I Communication (Maximum format: A4 (210 x 297 mm) issued by: Name of administration: Concerning: 2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of compressed hydrogen storage system with regard to the safety-related performance of hydrogen-fuelled vehicles pursuant to Regulation No. 134
10.changed
10.changed
10.changed
Annex 2changed
Model A (See paragraphs 4.4. to 4.4.2. of this Regulation) 134R - 01185 00185 a = 8 mm min The above approval mark affixed to a vehicle/ storage system/specific component shows that the vehicle/storage system/specific component type concerned has been approved in Belgium (E 6) for its the safety-related performance of hydrogen-fuelled vehicles pursuant to UN Regulation No. 134. The first two digits of the approval number indicate that the approval already contained was granted in accordance with the 01 series requirements of amendments at the time of approval. Regulation No. 134 in its original form. Model B (See paragraph 4.5. of this Regulation) 100 02 2492 134 01 00 1628 a = 8 mm min. The above approval mark affixed to a vehicle shows that the road vehicle concerned has been approved in the Netherlands (E 4) pursuant to UN Regulations Nos. 134 and 100.* The approval number indicates that, at the dates when the respective approvals were granted, UN Regulation No. 100 was amended by the 02 series of amendments and UN Regulation No. 134 was amended by the 01 series of amendments. still in its original form. * The latter number is given only as an example.
2.1.added
The burst test is conducted at 20 (±5) °C using a non-corrosive fluid. The rate
of pressurization is less than or equal to 1.4 MPa/sec for pressures higher
than 150 per cent of the nominal working pressure. If the rate exceeds 0.35
MPa/sec at pressures higher than 150 per cent NWP, then either the container
is placed in series between the pressure source and the pressure measurement
device, or the time at the pressure above a target burst pressure exceeds 5
seconds. The burst pressure of the container shall be recorded.
2.2.changed
The test is performed in accordance with the following procedure: (a) The container is filled with a non-corrosive fluid; (b) The container and fluid are stabilized at the specified temperature and relative humidity at the start of testing; the environment, fuelling fluid and container skin are maintained at the specified temperature for the duration of the testing. The container temperature may vary from the environmental temperature during testing; (c) The container is pressure cycled between 2 (±1) MPa and the target pressure at a rate not exceeding 10 cycles per minute for the specified number of cycles; (d) The temperature of the hydraulic fluid within the container is maintained and monitored at the specified temperature. Annex 3
3.3.changed
The test proceeds in the following sequence: (a) Surface flaw generation: Two longitudinal saw cuts are made on the bottom outer surface of the unpressurized horizontal storage container along the cylindrical zone close to but not in the shoulder area. The first cut is at least 1.25 mm deep and 25 mm long toward the valve end of the container. The second cut is at least 0.75 mm deep and 200 mm long toward the end of the container opposite the valve; (b) Pendulum impacts: The upper section of the horizontal storage container is divided into five distinct (not overlapping) areas 100 mm in diameter each (see Figure 2). After 12 hours preconditioning at -40 °C in an environmental chamber, the centre of each of the five areas sustains the impact of a pendulum having a pyramid with equilateral faces and square base, the summit and edges being rounded to a radius of 3 mm. The centre of impact of the pendulum coincides with the centre of gravity of the pyramid. The energy of the pendulum at the moment of impact with each of the five marked areas on the container is 30 J. The container is secured in place during pendulum impacts and not under pressure. Annex 3
3.4.changed
Each of the 5 areas of the unpressurized container preconditioned by pendulum impact (Annex 3, paragraph 3.3.) is exposed to one of five solutions: (a) 19 per cent (by volume) sulphuric acid in water (battery acid); (b) 25 per cent (by weight) sodium hydroxide in water; (c) 5 per cent (by volume) methanol in gasoline (fluids in fuelling stations); (d) 28 per cent (by weight) ammonium nitrate in water (urea solution); and (e) 50 per cent (by volume) methyl alcohol in water (windshield washer fluid). The test container is oriented with the fluid exposure areas on top. A pad of glass wool approximately 0.5 mm thick and 100 mm in diameter is placed on each of the five preconditioned areas. A sufficient amount of the test fluid is applied to the glass wool sufficient to ensure that the pad is wetted across its surface and through its thickness for the duration of the test. The exposure of the container with the glass wool is maintained for 48 hours with the container held at 125 per cent NWP (+2/-0 MPa) (applied hydraulically) and 20 (±5) °C before the container is subjected to further testing. Pressure cycling is performed to the specified target pressures according to paragraph 2.2. of this Annex 6.2.2.2. at 20 (±5) °C for the specified numbers of cycles. The glass wool pads are removed and the container surface is rinsed with water the final 10 cycles to specified final target pressure are conducted.
2.deleted
1.deleted
4.2.changed
A storage system is fully filled with hydrogen gas at 115 per cent NWP (+2/-0 (+2/- 0 MPa) (full fill density equivalent to 100 per cent NWP at +15 °C is 113 per cent NWP at +55 °C) and held at +55 °C in a sealed container until steady- state permeation or 30 hours, whichever is longer. The total steady-state discharge rate due to leakage and permeation from the storage system is measured.
4.3.changed
A bubble test may be used to fulfil this requirement. The following procedure is used when conducting the bubble test: (a) The exhaust of the shut-off valve (and other internal connections to hydrogen systems) shall be capped for this test (as the test is focused on external leakage). At the discretion of the tester, the test article may be immersed in the leak-test fluid or leak-test fluid applied to the test article when resting in open air. Bubbles can vary greatly in size, depending on conditions. The tester estimates the gas leakage based on the size and rate of bubble formation. (b) Note: For a localized rate of 0.005 mg/sec (3.6 Nml/min), the resultant allowable rate of bubble generation is about 2,030 bubbles per minute for a typical bubble size of 1.5 mm in diameter. Even if much larger bubbles are formed, the leak should be readily detectable. For an unusually large bubble size of 6 mm in diameter, the allowable bubble rate would be approximately 32 bubbles per minute. Annex 3
5.changed
5.1.2.changed
The following test requirements apply whether Method 1 or 2 (above) is used: (a) The container assembly is filled with compressed hydrogen gas at 100 per cent of NWP (+2/-0 MPa). The container assembly is positioned horizontally approximately 100 mm above the fire source; (b) Localized portion of the fire test: (i) The localized fire exposure area is located on the test article furthest from the TPRD(s). If Method 2 is selected and more vulnerable areas are identified for a specific vehicle installation configuration, the more vulnerable area that is furthest from the TPRD(s) is positioned directly over the initial fire source; (ii) The fire source consists of LPG burners configured to produce a uniform minimum temperature on the test article measured with a minimum 5 thermocouples covering the length of the test article up to 1.65 m maximum (at least 2 thermocouples within the localized fire exposure area, and at least 3 thermocouples equally spaced and no more than 0.5 m apart in the remaining area) located 25 (±10) mm from the outside surface of the test article along its longitudinal axis. At the option of the manufacturer or testing facility, additional thermocouples may be located at TPRD sensing points or any other locations for optional diagnostic purposes; (iii) Wind shields are applied to ensure uniform heating; (iv) The fire source initiates within a 250 (±50) mm longitudinal expanse positioned under the localized fire exposure area of the test article. The width of the fire source encompasses the entire diameter (width) of the storage system. If Method 2 is selected, the length and width shall be reduced, if necessary, to account for vehicle-specific features; (v) As shown in Figure 3 the temperature of the thermocouples in the localized fire exposure area has increased continuously to at least 300 °C within 1 minute of ignition, to at least 600 °C within 3 minutes of ignition, and a temperature of at least 600 °C is maintained for the next 7 minutes. The temperature in the localized fire exposure area shall not exceed 900 °C during this period. Compliance to the thermal requirements begins 1 minute after entering the period with minimum and maximum limits and is based on a 1-minute rolling average of each thermocouple in the region of interest. (Note: The temperature outside the region of the initial fire source is not specified during these initial 10 minutes from the time of ignition.). Annex 3
Table 1changed
Engulfing Fire Region Time (Outside the Localized Fire Localized Fire Region Period Region) Action 0-1 Ignite Burners Minute No Burner Operation Minimum temperature Not specified Not specified Maximum temperature Less than 900 oC Not specified Action Increase temperature and stabilize fire for start of 1-3 localized fire exposure Minutes No Burner Operation Minimum temperature Greater than 300 oC Not specified Maximum temperature Less than 900 oC Not specified Action Localized fire exposure continues Minimum No Burner Operation temperature 1-minute rolling average greater than 600 oC Not specified Maximum 1-minute rolling average 3-10 temperature less than 900 oC Minutes Not specified Action Increase temperature Main Burner Ignited at 10 Minimum minutes Temperature 1-minute rolling average greater than 600 oC Not specified Maximum 1-minute rolling average 10-11 temperature less than 1,100 oC Minutes Less than 1,100 oC Action Increase temperature and stabilize fire for start of Increase temperature and engulfing fire exposure stabilize fire for start of Minimum engulfing fire exposure temperature 1-minute rolling average greater than 600 oC Greater than 300 oC Maximum 1 minute rolling average 11-12 temperature less than 1,100 oC Minutes Less than 1,100 oC Action Engulfing fire exposure Engulfing fire exposure continues continues Minimum temperature 1-minute rolling average 1-minute rolling average greater than 800 oC 12 Greater than 800 oC Maximum 1 minute rolling average Minutes - 1-minute rolling average temperature less than 1,100 oC end of test less than 1,100 oC Annex 3 (d) Documenting results of the fire test The arrangement of the fire is recorded in sufficient detail to ensure the rate of heat input to the test article is reproducible. The results include the elapsed time from ignition of the fire to the start of venting through the TPRD(s), and the maximum pressure and time of evacuation until a pressure of less than 1 MPa is reached. Thermocouple temperatures and container pressure are recorded at intervals of every 10 sec or less during the test. Any failure to maintain specified minimum temperature requirements based on the 1-minute 1- minute rolling averages invalidates the test result. Any failure to maintain specified maximum temperature requirements based on the 1-minute rolling averages invalidates the test result only if the test article failed during the test.
5.2.added
Engulfing fire test:
The test unit is the compressed hydrogen storage system. The storage system
is filled with compressed hydrogen gas at 100 per cent NWP (+2/-0 MPa).
The container is positioned horizontally with the container bottom
approximately 100 mm above the fire source. Metallic shielding is used to
prevent direct flame impingement on container valves, fittings, and/or
pressure relief devices. The metallic shielding is not in direct contact with the
specified fire protection system (pressure relief devices or container valve).
A uniform fire source of 1.65 m length provides direct flame impingement on
the container surface across its entire diameter. The test shall continue until
the container fully vents (until the container pressure falls below 0.7 MPa).
Any failure or inconsistency of the fire source during a test shall invalidate
the result.
Flame temperatures shall be monitored by at least three thermocouples
suspended in the flame approximately 25 mm below the bottom of the
container. Thermocouples may be attached to steel cubes up to 25 mm on a
side. Thermocouple temperature and the container pressure shall be recorded
every 30 seconds during the test.
Within five minutes after the fire is ignited, an average flame temperature of
not less than 590 °C (as determined by the average of the two thermocouples
recording the highest temperatures over a 60 second interval) is attained and
maintained for the duration of the test.
If the container is less than 1.65 m i…
5.deleted
1.3.changed
Temperature cycling test (a) An unpressurized TPRD is placed in a liquid bath maintained at -40 °C or lower at least two hours. The TPRD is transferred to a liquid bath maintained at +85 °C or higher within five minutes, and maintained at that temperature at least two hours. The TPRD is transferred to a liquid bath maintained at -40 °C or lower within five minutes; (b) Step (a) is repeated until 15 thermal cycles have been achieved; (c) With the TPRD conditioned for a minimum of two hours in the -40 °C or lower liquid bath, the internal pressure of the TPRD is cycled with hydrogen gas between 2 MPa (+1/-0 MPa) and 80 per cent NWP (+2/-0 MPa) for 100 cycles while the liquid bath is maintained at -40 °C or lower; Annex 4 (d) Following the thermal and pressure cycling, the pressure relief device shall comply with the requirements of Leak test (Annex 4, paragraph 1.8.), except that the Leak test shall be conducted at -40 °C (+5/-0 °C). After the Leak test, the TPRD shall comply with the requirements of Bench top activation test (Annex 4, paragraph 1.9.) and then Flow rate test (Annex 4, paragraph 1.10.).
1.6.changed
Stress corrosion cracking test. For TPRDs containing components made of a copper-based alloy (e.g. brass), one TPRD unit is tested. All copper alloy components exposed to the atmosphere shall be degreased and then continuously exposed for ten days to a moist ammonia-air mixture maintained in a glass chamber having a glass cover. Aqueous ammonia having a specific gravity of 0.94 is maintained at the bottom of the glass chamber below the sample at a concentration of at least 20 ml per litre of chamber volume. The sample is positioned 35 (±5) mm above the aqueous ammonia solution and supported in an inert tray. The moist ammonia- air ammonia-air mixture is maintained at atmospheric pressure at 35 (±5) °C. Copper-based alloy components shall not exhibit cracking or delaminating due to this test.
1.8.changed
A TPRD that has not undergone previous testing is tested at ambient, high and low temperatures without being subjected to other design qualification tests. The unit is held for one hour at each temperature and test pressure before testing. The three temperature test conditions are: (a) Ambient temperature: condition the unit at 20 (±5) °C; test at 5 per cent NWP (+0/-2 MPa) and 150 per cent NWP (+2/-0 MPa); (b) High temperature: condition the unit at 85 °C or higher; test at 5 per cent NWP (+0/-2 MPa) and 150 per cent NWP (+2/-0 MPa); (c) Low temperature: condition the unit at -40 °C or lower; test at 5 per cent NWP (+0/-2 MPa) and 100 per cent NWP (+2/-0 MPa). Annex 4 Additional units undergo leak testing as specified in other tests in Annex 4, paragraph 1. with uninterrupted exposure at the temperature specified in those tests. At all specified test temperatures, the unit is conditioned for one minute by immersion in a temperature controlled fluid (or equivalent method). If no bubbles are observed for the specified time period, the sample passes the test. If bubbles are detected, the leak rate is measured by an appropriate method. The total hydrogen leak rate shall be less than 10 Nml/hr.
1.9.changed
Two new TPRD units are tested without being subjected to other design qualification tests in order to establish a baseline time for activation. Additional pre-tested units (pre-tested according to Annex 4, paragraphs 1.1., 1.3., 1.4., 1.5. or 1.7.) undergo bench top activation testing as specified in other tests in Annex 4, paragraph 1. (a) The test setup consists of either an oven or chimney which is capable of controlling air temperature and flow to achieve 600 (±10) °C in the air surrounding the TPRD. The TPRD unit is not exposed directly to flame. The TPRD unit is mounted in a fixture according to the manufacturer's installation instructions; the test configuration is to be documented; (b) A thermocouple is placed in the oven or chimney to monitor the temperature. The temperature remains within the acceptable range for two minutes prior to running the test; (c) The pressurized TPRD unit is inserted into the oven or chimney, and the time for the device to activate is recorded. Prior to insertion into the oven or chimney, one new (not pre-tested) TPRD unit is pressurized to no more than 25 per cent NWP (the pre-tested); TPRD units are pressurized to no more than 25 per cent NWP; and one new (not pre- tested) pre-tested) TPRD unit is pressurized to 100 per cent NWP; (d) TPRD units previously subjected to other tests in Annex 4, paragraph
1.10.changed
Flow rate test (a) Eight TPRD units are tested for flow capacity. The eight units consist of three new TPRD units and one TPRD unit from each of the following previous tests: Annex 4, paragraphs 1.1., 1.3., 1.4., 1.5. and 1.7. ; (b) Each TPRD unit is activated according to Annex 4, paragraph 1.9. After activation and without cleaning, removal of parts, or reconditioning, each TPRD unit is subjected to flow test using hydrogen, air or an inert gas; (c) Flow rate testing is conducted with a gas inlet pressure of 2 (±0.5) MPa. The outlet is at ambient pressure. The inlet temperature and pressure are recorded; (d) Flow rate is measured with accuracy within ±2 per cent. The lowest measured value of the eight pressure relief devices shall not be less than 90 per cent of the highest flow value.
1.7.added
;
(b) Each TPRD unit is activated according to Annex 4, paragraph 1.9.
After activation and without cleaning, removal of parts, or
reconditioning, each TPRD unit is subjected to flow test using
hydrogen, air or an inert gas;
(c) Flow rate testing is conducted with a gas inlet pressure of 2 (±0.5)
MPa. The outlet is at ambient pressure. The inlet temperature and
pressure are recorded;
(d) Flow rate is measured with accuracy within ±2 per cent. The lowest
measured value of the eight pressure relief devices shall not be less
than 90 per cent of the highest flow value.
2.changed
Testing shall be performed with hydrogen gas having gas quality compliant with ISO 14687-2/SAE J2719. All tests are performed at ambient temperature 20 (±5) °C unless otherwise specified. The check valve and shut-off shut- off valve qualification performance tests are specified as follows (see also Appendix 2):
2.2.changed
One unit that has not undergone previous testing is tested at ambient, high and low temperatures without being subjected to other design qualification tests. The three temperature test conditions are: (a) Ambient temperature: condition the unit at 20 (±5) °C; test at 5 per cent NWP (+0/-2 MPa) and 150 per cent NWP (+2/-0 MPa) ; (b) High temperature: condition the unit at 85 °C or higher ; test at 5 per cent NWP (+0/-2 MPa) and 150 per cent NWP (+2/-0 MPa) ; (c) Low temperature: condition the unit at -40 °C or lower; test at 5 per cent NWP (+0/-2 MPa) and 100 per cent NWP (+2/-0 MPa). Additional units undergo leak testing as specified in other tests in Annex 4, paragraph 2. with uninterrupted exposure at the temperatures specified in those tests. The outlet opening is plugged with the appropriate mating connection and pressurized hydrogen is applied to the inlet. At all specified test temperatures, the unit is conditioned for one minute by immersion in a temperature controlled fluid (or equivalent method). If no bubbles are observed for the specified time period, the sample passes the test. If bubbles are detected, the leak rate is measured by an appropriate method. The leak rate shall not exceed 10 Nml/hr of hydrogen gas. Annex 4
2.6.changed
The atmospheric exposure test applies to qualification of check valve and automatic shut-off valves if the component has non-metallic materials exposed to the atmosphere during normal operating conditions. (a) All non-metallic materials that provide a fuel containing seal, and that are exposed to the atmosphere, for which a satisfactory declaration of properties is not submitted by the applicant, shall not crack or show visible evidence of deterioration after exposure to oxygen for 96 hours Annex 4 at 70 °C at 2 MPa in accordance with ASTM D572 (Standard Test Method for Rubber- Deterioration by Heat and Oxygen); (b) All elastomers shall demonstrate resistance to ozone by one or more of the following: (i) Specification of elastomer compounds with established resistance to ozone; (ii) Component testing in accordance with ISO 1431/1, ASTM D1149, or equivalent test methods.
2.9.changed
For the valve units containing components made of a copper-based alloy (e.g. brass), one valve unit is tested. The valve unit is disassembled, all copper-based copper- based alloy components are degreased and then the valve unit is reassembled before it is continuously exposed for ten days to a moist ammonia-air mixture maintained in a glass chamber having a glass cover. Aqueous ammonia having a specific gravity of 0.94 is maintained at the bottom of the glass chamber below the sample at a concentration of at least 20 ml per litre of chamber volume. The sample is positioned 35 (±5) mm above the aqueous ammonia solution and supported in an inert tray. The moist ammonia- air ammonia-air mixture is maintained at atmospheric pressure at 35 (±5) ºC. Copper-based alloy components shall not exhibit cracking or delaminating due to this test.
2.10.changed
The valve unit is subjected to pre-cooled hydrogen gas at -40 ºC or lower at a flow rate of 30 g/sec at external temperature of 20 (±5) ºC for a minimum of three minutes. The unit is de-pressurized and re-pressurized after a two minute hold period. This test is repeated ten times. This test procedure is then repeated for an additional ten cycles, except that the hold period is increased to 15 minutes. The unit shall then comply with the requirements of the ambient temperature leak test specified in Annex 4, paragraph 2.2. Annex 4 - Appendix 1 Baseline Tests Performance and Stress Tests Overview of TPRD tests 1 xTPRD 5 xTPRD 1 xTPRD 2 xTPRD 1xTPRD 7 xTPRD 8 xTPRD (1.1.) (1.3.) (1.4.) (1.5.) (1.7.) (1.2.) Pressure Temperature Salt Corrosion Vehicle Drop and Accelerated Cycling Test Cycling Test Resistance Test Environment Vibration Test Life Test Test (1.8.) (1.8.) 5 xTPRD 3 xTPRD Leak Test Leak Test For 500h at Tlife For 10h at Tact 2 x TPRD Shall not Shall activate activate (1.9.) (1.9.) Only for TPRD with Bench Top Bench Top copper based alloys: Activation Test Activation Test 1 xTPRD 3 x TPRD. (1.6.) (1.10.) (1.10.) Stress Corrosion Annex 4 – Appendix 1 Flow Rate Test Flow Rate Test Cracking Test Annex 4 – Appendix 2 Annex 4 - Appendix 2 Baseline Tests Performance and Stress Tests 1x 1x 1x Overview of check valve and automatic shut-off valve tests 1x 1 x component 1 x component 1 x component 1 x component 1 x component component component component component (2.2.) (2.1.) (2.6.) (2.9.) (2.10) (2.8.) (2.5.) (2.4.) (2.3.) Leak Test Hydrostatic Atmospheric Stress Pre-Cool Vibration Test Vehicle Salt Extreme @20°C Strength Test Exposure Test Corrosion Hydrogen Environment Corrosion Temperature (Baseline) (Baseline) Cracking Test Exposure Test Test Resistance Pressure (pT) Test Cycling Test pT cycl.@20°C Visual Visual (2.2.) Inspection Inspection Leak Test @20°C (2.2) Leak Test @20°C pT cycl.@+85°C Applicable to Automatic shut-off valve (2.2.) Leak Test @+85°C 1 x component pT cycl.@-40°C (2.7.) (2.2.) Electrical Test Leak Test @-40°C Chatter flow test (2.2.) Leak Test @20°C (2.1.) Hydrostatic Strength Test Annex 5
1.changed
The crash tests used to evaluate post-crash hydrogen leakage are those set out in paragraph 7.2. of this Regulation. Prior to conducting the crash test, instrumentation is installed in the hydrogen storage system to perform the required pressure and temperature measurements if the standard vehicle does not already have instrumentation with the required accuracy. The storage system is then purged, if necessary, following manufacturer's directions to remove impurities from the container before filling the storage system with compressed hydrogen or helium gas. Since the storage system pressure varies with temperature, the targeted fill pressure is a function of the temperature. The target pressure shall be determined from the following equation: Ptarget = NWP x (273 + To) / 288 where NWP is the Nominal Working Pressure (MPa), T o is the ambient temperature to which the storage system is expected to settle, and Ptarget P target is the targeted fill pressure after the temperature settles. The container is filled to a minimum of 95 per cent of the targeted fill pressure and allowed to settle (stabilize) prior to conducting the crash test. The main stop valve and shut-off valves for hydrogen gas, located in the downstream hydrogen gas piping, are in normal driving condition immediately prior to the impact.
1.1.changed
Post-crash leak test: compressed hydrogen storage system filled with compressed hydrogen The hydrogen gas pressure, P0 (MPa) and temperature, T0 (°C) are measured immediately before the impact and then at a time interval, Δt (min), after the impact. The time interval, Δt, starts when the vehicle comes to rest after the impact and continues for at least 60 minutes. The time interval, Δt, shall be increased, if necessary, to accommodate measurement accuracy for a storage system with a large volume operating up to 70MPa; in that case, Δt is calculated from the following equation: Δt = VCHSS x NWP /1,000 x ((-0.027 x NWP +4) x Rs – 0.21) -1.7 x Rs where Rs = Ps / NWP, Ps is the pressure range of the pressure sensor (MPa), NWP is the Nominal Working Pressure (MPa), VCHSS is the volume of the compressed hydrogen storage system (L), and Δt is the time interval (min). If the calculated value of Δt is less than 60 minutes, Δt is set to 60 minutes. The initial mass of hydrogen in the storage system is calculated as follows: Po' = Po x 288 / (273 + T0) ρo' = –0.0027 x (P0')2 + 0.75 x P0' + 0.5789 Mo = ρo' x VCHSS The final mass of hydrogen in the storage system, M f, Mf, at the end of the time interval, Δt, is calculated as follows: Pf' = Pf x 288 / (273 + Tf) ρf' = –0.0027 x (Pf')2 + 0.75 x Pf' + 0.5789 Mf = ρf' x VCHSS where Pf is the measured final pressure (MPa) at the end of the time interval, and Tf is the measured final temperature (°C). The average hydrogen flow rate over the time interval (that shall be less than the criteria in paragraph 7.2.1.) is therefore VH2 = (Mf-Mo) / Δt x 22.41 / 2.016 x (Ptarget /Po) where VH2 is the average volumetric flow rate (NL/min) over the time interval and the term (Ptarget /Po) is used to compensate for differences between the measured initial pressure, Po, P o, and the targeted fill pressure Ptarget.
1.2.changed
Post-crash leak test: Compressed hydrogen storage system filled with compressed helium The helium gas pressure, P0 (MPa), and temperature T0 T 0 (°C), are measured immediately before the impact and then at a predetermined time interval after the impact. The time interval, Δt, starts when the vehicle comes to rest after the impact and continues for at least 60 minutes. The time interval, Δt, shall be increased if necessary in order to accommodate measurement accuracy for a storage system with a large volume operating up to 70MPa; in that case, Δt is calculated from the following equation: Δt = VCHSS x NWP /1,000 x ((-0.028 x NWP +5.5) x Rs – 0.3) – 2.6 x Rs where Rs = Ps / NWP, Ps is the pressure range of the pressure sensor (MPa), NWP is the Nominal Working Pressure (MPa), VCHSS is the volume of the compressed storage system (L), and Δt is the time interval (min). If the value of Δt is less than 60 minutes, Δt is set to 60 minutes. The initial mass of helium in the storage system is calculated as follows: Po' = Po x 288 / (273 + T0) ρo' = –0.0043 x (P0')2 + 1.53 x P0' + 1.49 Mo = ρo' x VCHSS The final mass of helium in the storage system, Mf, at the end of the time interval, Δt, is calculated as follows: Pf' = Pf x 288 / (273 + Tf) ρf' = –0.0043 x (Pf')2 + 1.53 x Pf' + 1.49 Mf = ρf' x VCHSS where Pf is the measured final pressure (MPa) at the end of the time interval, and Tf is the measured final temperature (°C). Annex 5 The average helium flow rate over the time interval is therefore VHe = (Mf-Mo) / Δt x 22.41 / 4.003 x (Ptarget/ Po) where VHe is the average volumetric flow rate (NL/min) over the time interval and the term Ptarget/ Po is used to compensate for differences between the measured initial pressure (Po) and the targeted fill pressure (Ptarget). Conversion of the average volumetric flow of helium to the average hydrogen flow is calculated with the following expression: VH2 = VHe / 0.75 where VH2 is the corresponding average volumetric flow of hydrogen (that shall be less than the requirements in paragraph 7.2.1. of this Regulation to comply with).
Annex 4 - Appendix 1deleted
Annex 4 - Appendix 2deleted
3.1.2.2.changed
Execution of the test (a) Test gas is blown to the hydrogen gas leakage detector; (b) Proper function of the warning system is confirmed when tested with the gas to verify function of the warning; (c) The main shut-off valve is confirmed to be closed when tested with the gas to verify function of the shut-down. For example, the monitoring of the electric power to the shut-off valve or of the sound of the shut-off valve activation may be used to confirm the operation of the main shut- off shut-off valve of the hydrogen supply.
3.2.1.3.changed
Prior to the test the vehicle is prepared to allow remotely controllable hydrogen releases from the hydrogen system. The number, location and flow capacity of the release points downstream of the main hydrogen shut-off valve are defined by the vehicle manufacturer taking worst case leakage Annex 5 scenarios under single failure condition into account. As a minimum, the total flow of all remotely controlled releases shall be adequate to trigger demonstration of the automatic "warning" and hydrogen shut-off functions.
Annex 6deleted