Compare versions of UN R136
Vehicles of category L with regard to specific requirements for the electric power train
1.1.changed
Part I: Safety requirements with respect to the electric power train of vehicles of category L1 with a maximum design speed exceeding 6 km/h, equipped with an one or more traction motor(s) operated by electric power train, excluding vehicles and not permanently connected to the grid. Part I of this Regulation does not cover high-voltage grid, as well as their high voltage components and systems which are not galvanically connected to the high voltage bus of the electric power train.
1.2.changed
Energy Storage System (REESS) of vehicles of category L with a maximum design speed exceeding 6 km/h, equipped with an one or more traction motors operated by electric power train, excluding vehicles and not permanently connected to the grid. Part II of this Regulation does not apply to a battery REESS(s) whose primary use is to supply power for starting the engine and/or lighting and/or other vehicle auxiliaries’ systems." auxiliaries systems.
2.2.changed
2.3.changed
2.4.changed
2.5.changed
2.6.changed
2.7.changed
2.8.changed
2.9.changed
2.10.changed
2.11.changed
2.12.changed
2.13.changed
2.14.changed
2.15.changed
2.16.changed
2.17.changed
2.18.changed
2.19.changed
2.20.changed
2.21.changed
2.22.changed
2.23.changed
2.24.changed
2.25.changed
2.26.changed
2.27.changed
2.28.changed
2.29.changed
2.30.changed
2.31.changed
2.32.changed
2.33.changed
2.34.changed
2.35.changed
2.36.changed
2.37.changed
2.38.changed
2.39.changed
2.40.changed
2.41.changed
2.42.changed
2.43.changed
2.44.changed
2.45.changed
2.46.deleted
3.1.changed
Part I: Approval of a vehicle type with regard to specific requirements for its electrical safety, including the electric power train. High Voltage System
2.47.deleted
2.48.deleted
2.49.deleted
3.1.2.1.changed
Detailed description of the vehicle type with as regards to the electric power train and the galvanically connected high voltage bus galvanically connected to it. bus.
2.50.deleted
2.51.deleted
2.52.deleted
2.53.deleted
2.54.deleted
2.55.deleted
2.56.deleted
2.57.deleted
2.58.deleted
2.59.deleted
4.2.changed
An approval number shall be assigned to each type approved approved. Its first two digits (at present 00 for the Regulation in accordance with Schedule 4 its form) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the Agreement (E/ECE/TRANS/505/Rev.3 and Amend.1). approval. The same Contracting Party shall not assign the same number to another vehicle type.
4.4.changed
There shall be affixed, conspicuously and in a readily accessible place specified on the approval form, to every vehicle or REESS or separate technical unit conforming to a type approved under this Regulation an international approval mark consisting of:
4.4.3.changed
In the case of an approval of a REESS or a separate technical unit of the REESS the "R" shall be followed by the symbol "ES".
4.6.2.changed
In the case of a REESS or separate technical unit approved as a REESS, the approval mark shall be affixed on the major element of the REESS by the manufacturer.
4.7.changed
Annex 2 to this Regulation gives examples of the arrangements of the approval mark. 3 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.7.
5.changed
Part I: Requirements of a vehicle with regard to specific requirements for the electric power train its electrical safety
5.1.changed
These electrical safety requirements apply to high voltage buses of electric power train and electrical components which are galvanically connected to the high voltage bus of electric power train under conditions where they are not connected to external high voltage power supplies.
5.1.1.changed
Protection against direct contact with high voltage live parts is also required for vehicles equipped with any REESS type approved under Part II of this Regulation. 3 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.3. The protection against direct contact with the high voltage live parts, shall comply with paragraphs 5.1.1.1. and 5.1.1.2. These protections (solid insulator, electrical protection barrier, enclosure, etc.) shall not be able to be opened, disassembled or removed without the use of tools.
5.1.1.1.changed
For high voltage protection of live parts inside the passenger compartment or luggage compartment, the protection degree IPXXD shall be provided.
5.1.1.2.changed
5.1.1.2.1.changed
For vehicles with a passenger compartment, the protection degree IPXXB shall be provided. satisfied.
5.1.1.2.2.changed
For vehicles without passenger compartment, the protection degree IPXXD shall be provided. satisfied.
5.1.1.3.changed
Connectors (including the vehicle inlet) are deemed to meet this requirement if: (a) They comply with 5.1.1.1. and 5.1.1.2. when separated without the use of tools; or (b) They are located underneath the floor and are provided with a locking mechanism; or (c) They are provided with a locking mechanism (at least two distinct actions are needed to separate the connector from its mating component). Additionally, and other components, not being part of the connector, components shall be removed with the use of tools, tools in order to separate the connector; or (c) (d) The voltage of the live parts becomes equal or below 60 V DC or equal or below 30 V AC (rms) within one second after the connector is separated.
5.1.1.4.changed
For a high voltage service disconnect which can be opened, disassembled or removed without tools, it is acceptable if protection degree IPXXB shall be is satisfied when under a condition where it is opened, disassembled or removed. removed without tools.
5.1.1.5.1.changed
Figure 1added
yellow, the bordering and the arrow shall be black.
Marking of high voltage equipment
5.1.1.5.2.changed
The symbol shall also be visible on enclosures and electrical protection barriers, which, when removed expose live parts of high voltage circuits. This provision is optional to any connector for high voltage buses. This provision shall not apply to any of the following cases: (a) Where electrical protection barriers or enclosures cannot be physically accessed, opened, or removed; unless other vehicle components are removed with the use of tools; (b) Where electrical protection barriers or enclosures are located underneath the vehicle floor.5.1.1.5.3. Cables for high voltage buses which are not located within enclosures shall be identified by having an outer covering with the colour orange. floor.
5.1.1.5.3.added
Cables for high voltage buses which are not located within enclosures shall
be identified by having an outer covering with the colour orange.
5.1.2.added
Protection against indirect contact is also required for vehicles with high
voltage live parts equipped with any REESS type approved under Part II of
this Regulation.
5.1.2.1.changed
For protection against electrical shock which could arise from indirect contact, the exposed conductive parts, such as the conductive electrical protection barrier and enclosure, shall be galvanically connected securely to the electrical chassis by connection with electrical wire or ground cable, or by welding, or by connection using bolts, etc. so that no dangerous potentials are produced.
5.1.2.2.changed
The resistance between all exposed conductive parts and the electrical chassis shall be lower than 0.1 Ω when there is current flow of at least 0.2 A. The resistance between any two simultaneously reachable exposed conductive parts of the electrical protection barriers that are less than 2.5 m from each other shall not exceed 0.2 Ω. This resistance may be calculated using the separately measured resistances of the relevant parts of electric path. This requirement is satisfied if the galvanic connection has been established by welding. In case of doubt or if the connection is established by other means than welding, a measurement shall be made by using one of the test procedures described in Annex 4.
5.1.2.3.changed
In the case of motor vehicles which are intended to be connected to the grounded external electric power supply through the conductive connection, a device to enable the galvanically galvanical connection of the electrical chassis to the earth ground for the external electric power supply shall be provided. The device shall enable connection to the earth ground before exterior voltage is applied to the vehicle and retain the connection until after the exterior voltage is removed from the vehicle. Compliance to this requirement may shall be demonstrated either by using the connector specified by the vehicle manufacturer, or by visual inspection or drawings. The above requirements are only applicable for vehicles when charging from a stationary charging point, with a charging cable of finite length, through a vehicle coupler. analysis.
5.1.2.4.1.1.changed
For vehicle with on-board charger the test shall be conducted according to Annex 10A 9A to this regulation.
5.1.2.4.2.1.changed
This test shall be conducted according to Annex 10B 9B of this UN Regulation. regulation.
5.1.3.changed
This paragraph shall not apply to chassis connected electrical circuits that are galvanically connected to each other, where the DC maximum voltage between any live part of these circuits is connected to and the electrical chassis and the specific voltage condition is fulfilled. or any exposed conductive part does not exceed 30 V AC (rms) or 60 V DC.
5.1.3.1.changed
5.1.3.2.changed
If AC buses and DC buses are galvanically connected, isolation resistance between any high voltage bus and the electrical chassis shall have a minimum value of 500 Ω/volt of the working voltage. However, if all AC high voltage buses are protected by one of the two following measures, isolation resistance between any high voltage bus and the electrical chassis shall have a minimum value of 100 Ω/V of the working voltage: 4 Example of the content in the manual: "If during charging, your vehicle or charger becomes submerged in water you should not touch either the vehicle nor the charger because of danger of electric shock. Also, do not use the battery nor the vehicle and ask your dealer to take (appropriate) measures." (a) Double or more layers of solid insulators, barriers or enclosures that meet the requirement in paragraph 5.1.1. independently, for example wiring harness; (b) Mechanically robust protections that have sufficient durability over vehicle service life such as motor housings, electronic converter cases or connectors; The isolation resistance between the high voltage bus and the electrical chassis may be demonstrated by calculation, measurement or a combination of both. The measurement shall be conducted according to Annex 4A "Isolation resistance measurement method for vehicle based tests".
5.1.3.3.changed
5.1.3.4.changed
Isolation resistance requirement for the coupling system used to charge the REESS For the vehicle conductive connection device coupling system (used to charge the REESS and intended to be conductively connected to the grounded external AC power supply and the electrical circuit that is galvanically connected to the vehicle conductive connection device during charging of the REESS, supply) the isolation resistance between the high voltage bus and the electrical chassis shall be minimum 500 Ω/V at least 1 MΩ when the conductive connection charger coupler is disconnected and the isolation resistance is measured at the high voltage live parts (contacts) of the vehicle conductive connection device. disconnected. During the measurement, the REESS may be disconnected.
5.2.1.1.changed
For a REESS which has been type approved in accordance with Part II of this series of Amendments to this Regulation, installation shall be in accordance with the instructions provided by the manufacturer of the REESS, and in conformity with the description provided in Part 2 of Annex 1, Appendix 2 6 to this Regulation.
5.2.1.2.changed
The REESS including related vehicle components, systems and structure as applicable, shall comply with the respective requirements of paragraph 6. of this Regulation.
5.3.added
A momentary indication shall, as minimum, be given to the driver when the
vehicle is in "active driving possible mode''.
However, this provision does not apply under conditions where an internal
combustion engine directly or indirectly provides the vehicle´s propulsion
power.
When leaving the vehicle, the driver shall be informed by a signal (e.g.
optical or audible signal) if the vehicle is still in the active driving possible
mode.
If the onboard REESS can be externally charged by the user, movement
caused by the vehicle's propulsion system shall not be possible while the
external electric power supply is physically connected to the vehicle inlet.
For vehicles with a permanently connected recharge cable, the requirement
above is not applicable if using the cable to charge the vehicle prevents the
use of the vehicle (e.g. seat cannot be closed, the cable position does not
allow the rider to sit in or step into the vehicle). This requirement shall be
demonstrated by using the connector specified by the vehicle manufacturer.
The state of the drive direction control unit shall be identified to the driver.
5.3.1.1.added
At least two deliberate and distinctive actions shall be performed by the
driver at the start-up to select the active driving possible mode.
5.3.1.2.added
Only a single action shall be required to deactivate the active driving possible
mode.
5.3.1.3.added
Indication of temporary reduced power (i.e. not resulting from a failure)
and/or of state of charge (SOC) of REESS.
5.3.1.3.1.added
The vehicle shall have a function/device that indicates to the driver/rider if
the power is automatically reduced below a certain level, (e.g. due to
activation of the output controller to protect the REESS or the propulsion
system) or due to a low SOC.
5.3.1.3.2.added
The conditions under which these indications are given shall be determined
by the manufacturer.
A brief description of the power reduction and indicating strategy will be
prescribed in Annex 6.
5.1.4.deleted
5.3.1.4.added
It shall not be possible to activate the vehicle reverse control function whilst
the vehicle is in forward motion.
5.1.4.1.deleted
5.1.4.2.deleted
5.1.4.3.deleted
5.4.2.changed
The test shall be conducted according to the method in Annex 7 of the present Regulation. The hydrogen sampling and analysis shall be prescribed. Other analysis methods can be approved if it is proven that they give equivalent results.
5.1.3.deleted
5.4.3.changed
During a normal charge procedure in the conditions given in Annex 8, 7, hydrogen emissions shall be below 125 g during 5 h, or below 25 x t2 t 2 g during t2 (in h).
5.1.4.4.deleted
5.4.4.changed
During a charge carried out by a charger presenting a failure (conditions given in Annex 8), 7), hydrogen emissions shall be below 42 g. The charger shall limit such a failure to 30 minute maximum.
5.4.10.changed
The approval granted to a vehicle type relative to hydrogen emissions can be extended to different vehicle types belonging to the same family, in accordance with the definition of the family given in Annex 8, 7, Appendix 2.
5.2.5.deleted
6.1.changed
The procedures prescribed in Annex 9 8 of this Regulation shall be applied.
5.2.6.deleted
6.2.1.changed
The test shall be conducted in accordance with Annex 9A 8A of this Regulation. A REESS that passes the vibration test in all three mutually perpendicular X, Y and Z directions may be mounted in any orientation on the vehicle.
5.3.1.deleted
5.3.2.deleted
6.2.2.1.changed
During the test, there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS (s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
5.3.3.deleted
6.2.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B 4B to this Regulation shall not be less than 100 Ω/Volt.
5.3.4.1.deleted
6.3.1.changed
The test shall be conducted in accordance with Annex 9B 8B to this Regulation.
5.3.4.2.deleted
5.3.4.3.deleted
6.3.2.1.changed
During the test, there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS (s) REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
5.3.4.3.1.deleted
6.3.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B to 4B of this Regulation shall not be less than 100 Ω/Volt.
5.3.4.3.2.deleted
5.3.4.4.deleted
6.4.1.1.added
The test shall be conducted in accordance with Annex 8C of this Regulation.
6.4.1.2.1.changed
During the test there shall be no evidence of (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.4.1.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B 4B of this Regulation shall not be less than 100 Ω / Volt.
6.4.2.1.changed
This test shall apply to vehicles with a centre and/or side stand. The test shall be conducted in accordance with Annex 9D 8D of this Regulation.
6.4.2.2.1.changed
During the test there shall be no evidence of (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.4.2.2.2.changed
For a high voltage REESS the isolation resistance of the Tested-Device tested-device shall ensure at least 100 Ω/V Ω/Volt for the whole REESS measured after the test in accordance with Annex 5B 4B to this UN Regulation.
6.5.1.changed
The test shall be conducted in accordance with Annex 9E 8E in due consideration of paragraph 3.2.1. of Annex 9E. 8E. The approval of a REESS tested according to this paragraph shall be limited to approvals for a specific vehicle type.
6.5.2.changed
The test shall be conducted in accordance with Annex 9E 8E in due consideration of paragraph 3.2.2. of Annex 9E. 8E.
6.6.1.changed
The test shall be conducted in accordance with Annex 8F of this Regulation.
6.6.2.1.changed
During the test there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.6.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B 4B to this Regulation shall not be less than 100 Ω/V.
6.7.1.changed
The test shall be conducted in accordance with Annex 9G 8G to this Regulation.
6.7.2.1.changed
During the test there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.7.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B 4B to this Regulation shall not be less than 100 Ω/V.
6.8.1.changed
The test shall be conducted in accordance with Annex 9H 8H to this Regulation.
6.8.2.1.changed
During the test there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.8.2.2.changed
For a high voltage REESS the isolation resistance measured after the test in accordance with Annex 5B 4B to this Regulation shall not be less than 100 Ω/V.
6.9.1.changed
The test shall be conducted in accordance with Annex 9I 8I to this Regulation.
6.9.2.1.changed
During the test there shall be no evidence of: (a) Electrolyte leakage; (b) Rupture (applicable to high voltage REESS(s) only); (c) Venting (for REESS other than open-type traction battery); Fire; (d) Fire; (e) Explosion. The evidence of REESS venting shall be verified only for vehicles with a passenger compartment. The evidence Evidence of electrolyte leakage shall be verified by visual inspection without disassembling any part of the Tested-Device. An appropriate technique shall, if necessary, be used in order to confirm if there is any electrolyte leakage from the REESS resulting from the test. The evidence of venting shall be verified by visual inspection without disassembling any part of the Tested-Device. tested-device.
6.9.2.2.changed
For a high voltage REESS, the isolation resistance measured after the test in accordance with Annex 5B 4B to this Regulation shall not be less than 100 Ω/V.
6.10.changed
6.10.1.changed
6.10.2.added
For hydrogen emissions see paragraph 5.4. of this Regulation.
For emission free systems with closed chemical process no verification is
necessary.
7.1.changed
Every modification of the vehicle or REESS type with regard to this Regulation shall be notified to the Type Approval Authority which approved the vehicle or REESS type. The Authority may then either: (a) Decide, in consultation with the manufacturer, that a new type approval is to be granted; or (b) Apply the procedure contained in paragraph 7.1.1. (Revision) and, if applicable, the procedure contained in paragraph 7.1.2. (Extension).
7.1.1.changed
7.1.2.changed
7.2.added
Confirmation or refusal of approval, specifying the alteration, shall be
communicated by the procedure specified in paragraph 4.3. above to the
Parties to the Agreement applying this Regulation.
7.3.added
The Type Approval Authority issuing the extension of approval shall assign a
series number to each communication form drawn up for such an extension
and inform thereof the other Parties to the 1958 Agreement applying the
Regulation by means of a communication form conforming to the model in
Annex 1 (Part 1 or Part 2) to this Regulation.
8.3.added
The holder of the approval shall, in particular:
8.3.1.added
Ensure the existence of procedures for the effective quality control of
vehicles or REESS;
8.3.2.added
Have access to the testing equipment necessary for checking the conformity
of each approved type;
8.3.3.added
Ensure that test result data are recorded and that the annexed documents
remain available for a period to be determined in agreement with the Type
Approval Authority;
8.3.4.added
Analyse the results of each type of test, in order to verify and ensure the
consistency of characteristics of the vehicle or REESS, making allowance for
permissible variations in industrial production;
8.3.5.added
Ensure that for each type of vehicle or component type at least the tests
prescribed in the relevant part(s) of this Regulation are carried out;
8.3.6.added
Ensure that any set of samples or test pieces giving evidence of non-
conformity with the type of test in question shall give rise to a further
sampling and test. All necessary steps shall be taken to re-establish
conformity of the corresponding production.
8.4.added
The Type Approval Authority which has granted type approval may at any
time verify the conformity control methods applied in each production unit.
8.4.1.added
At every inspection, the test records and production records shall be
presented to the visiting inspector.
8.4.2.added
The inspector may take samples at random to be tested in the manufacturer's
laboratory. The minimum number of samples may be determined according
to the results of the manufacturer's own checks.
8.4.3.added
When the quality level appears unsatisfactory or when it seems necessary to
verify the validity of the tests carried out in application of paragraph 8.4.2.,
the inspector shall select samples to be sent to the technical service which has
conducted the type approval tests.
8.4.4.added
The Type Approval Authority may carry out any test prescribed in this
Regulation.
8.4.5.added
The normal frequency of inspections by the Type Approval Authority shall
be one per year. If unsatisfactory results are recorded during one of these
visits, the Type Approval Authority shall ensure that all necessary steps are
taken to re-establish the conformity of production as rapidly as possible.
9.1.changed
The approval granted in respect of a vehicle/REESS type, pursuant to this Regulation may be withdrawn if the requirements laid down in paragraph 8. above are not complied with. with, or if the vehicle/REESS or its components fail to pass the tests provided for in paragraph 8.3.5. above.
9.2.changed
If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously granted, it shall forthwith so notify the other Contracting Parties applying this Regulation, by means of a copy of communication form conforming to the approval form bearing at the end, Model in large letters, the signed and dated annotation "APPROVAL WITHDRAWN". Annex 1 (Part 1 or Part 2) to this Regulation.
6.10.2.1.deleted
10.changed
If the holder of the approval completely ceases to manufacture a vehicle/REESS type approved in accordance with this Regulation, he shall so inform the Type Approval Authority which granted the approval. Upon receiving the relevant communication, that Type Approval Authority shall inform thereof the other Contracting Parties to the 1958 Agreement applying this Regulation by means of a copy of communication form conforming to the approval form bearing at the end, model in large letters, the signed and dated annotation "PRODUCTION DISCONTINUED". Annex 1 (Part 1 or Part 2) to this Regulation.
6.10.2.2.deleted
11.changed
Names and addresses of Technical Services responsible for conducting approval tests and of Type Approval Authorities The Contracting Parties to the 1958 Agreement applying this Regulation shall communicate to the United Nations Secretariat the names and addresses of the Technical Services responsible for conducting approval tests and the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval or production definitively discontinued, issued in other countries are to be sent. Annex 1 – Part 1 Annex 1 - Part 1 Communication (Maximum format: A4 (210 x 297 mm)) Issued by: Name of administration: Concerning:2 Approval granted, Approval extended, Approval refused, Approval withdrawn, Production definitively discontinued, of a vehicle type with regard to its electrical safety pursuant to Regulation No. 136
6.10.2.3.deleted
6.1.1.changed
1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply. Annex 1 – Part 1
6.11.deleted
17.changed
The documents filed with the request for approval or extension may be obtained on request. Annex 1 – Part 2 Annex 1 – Part 2 Communication (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a REESS type as component/separate technical unit2 pursuant to Regulation No. 136 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply. Annex 1 – Part 2
6.12.deleted
17.changed
The documents filed with the request for approval or extension may be obtained on request. Annex 2
6.12.1.deleted
6.12.2.deleted
Figure 1changed
a = 8 mm min. The approval mark in Figure 1 affixed to a vehicle shows that the road vehicle type concerned has been approved in the Netherlands (E 4), pursuant to Regulation No. 136, and under the approval number 012492. 002492. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of UN Regulation No. 136 as amended by the 01 series of amendments. in its original form.
Figure 2changed
a = 8 mm min. The approval mark in Figure 2 affixed to a REESS shows that the REESS type ("ES") concerned has been approved in the Netherlands (E 4), pursuant to Regulation No. 136, and under the approval number 012492. 002492. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of UN Regulation No. 136 as amended by the 01 series of amendments. in its original form. Model B 136 01 00 2492 78 (See paragraph 4.5. of this Regulation) 03 1628 a = 8 mm min. (See paragraph 4.5. of this Regulation) The above approval mark affixed to a vehicle shows that the road vehicle concerned has been approved in the Netherlands (E4) pursuant to UN Regulations Nos. 136 and 781 . 781. The approval number indicates that, at the dates when the respective approvals were granted, UN Regulation No. 136 was amended by the 01 series of amendments still in its original form and UN Regulation No. 78 was amended by 03 series of amendments. 1 The latter number is given only as an example.
6.12.1.deleted
6.13.deleted
6.13.1.deleted
2.changed
The access probe is pushed against any openings of the enclosure with the force specified in Table 1. If it partly or fully penetrates, it is placed in every possible position, but in no case shall the stop face fully penetrate through the opening. Internal electrical protection barriers are considered part of the enclosure. A low-voltage supply (of not less than 40 V and not more than 50 V) in series with a suitable lamp should be connected, if necessary, between the probe and live parts inside the electrical protection barrier or enclosure. The signal-circuit method should also be applied to the moving live parts of high voltage equipment. Internal moving parts may be operated slowly, where this is possible.
6.13.2.deleted
3.changed
The access probe shall not touch live parts. If this requirement is verified by a signal circuit between the probe and live parts, the lamp shall not light. In the case of the test for protection degree IPXXB, the jointed test finger may penetrate to its 80 mm length, but the stop face (diameter 50 mm x 20 mm) shall not pass through the opening. Starting from the straight position, both joints of the test finger shall be successively bent through an angle of up to 90 degrees with respect to the axis of the adjoining section of the finger and shall be placed in every possible position. In case of the tests for protection degree IPXXD, the access probe may penetrate to its full length, but the stop face shall not fully penetrate through the opening. Annex 3
6.14.deleted
6.14.1.deleted
Figure 1changed
6.14.2.deleted
1.added
The isolation resistance for each high voltage bus of the vehicle shall be
measured or shall be determined by calculation using measurement values
from each part or component unit of a high voltage bus (hereinafter referred
to as the "divided measurement").
6.15.deleted
2.added
The isolation resistance measurement shall be conducted by selecting an
appropriate measurement method from among those listed in paragraphs 2.1.
through 2.2. of this annex, depending on the electrical charge of the live parts
or the isolation resistance, etc.
The range of the electrical circuit to be measured shall be clarified in
advance, using electrical circuit diagrams, etc.
Moreover, modification necessary for measuring the isolation resistance may
be carried out, such as removal of the cover in order to reach the live parts,
drawing of measurement lines, change in software, etc.
In cases where the measured values are not stable due to the operation of the
on-board isolation resistance monitoring system, etc., necessary modification
for conducting the measurement may be carried out, such as stopping of the
operation of the device concerned or removing it. Furthermore, when the
device is removed, it shall be proven, using drawings, etc., that it will not
change the isolation resistance between the live parts and the electrical
chassis.
Utmost care shall be exercised as to short circuit, electric shock, etc., for this
confirmation might require direct operations of the high-voltage circuit.
6.15.1.deleted
6.15.1.1.deleted
2.1.1.added
An isolation resistance test instrument capable of applying a DC voltage
higher than the working voltage of the high voltage bus shall be used.
6.15.1.2.deleted
2.1.2.added
An insulator resistance test instrument shall be connected between the live
parts and the electrical chassis. Then, the isolation resistance shall be
measured by applying a DC voltage at least half of the working voltage of the
high voltage bus.
If the system has several voltage ranges (e.g. because of boost converter) in
galvanically connected circuit and some of the components cannot withstand
the working voltage of the entire circuit, the isolation resistance between
those components and the electrical chassis can be measured separately by
applying at least half of their own working voltage with those component
disconnected.
Annex4A
6.15.2.deleted
6.15.2.1.deleted
2.2.1.added
The high voltage-bus shall be energized by the vehicle’s own REESS and/or
energy conversion system and the voltage level of the REESS and/or energy
conversion system throughout the test shall be at least the nominal operating
voltage as specified by the vehicle manufacturer.
6.15.2.2.deleted
2.2.2.added
The voltmeter used in this test shall measure DC values and shall have an
internal resistance of at least 10 MΩ.
6.15.2.3.deleted
6.15.2.4.deleted
2.2.3.1.added
The voltage is measured as shown in Figure 1 and the high voltage bus
voltage (Vb) is recorded. Vb shall be equal to or greater than the nominal
operating voltage of the REESS and/or energy conversion system as specified
by the vehicle manufacturer.
Measurement of Vb, V1, V2
Electrical Chassis
Energy Conversion
System Assembly V2 REESS Assembly
High Voltage Bus
+ +
Energy
Traction System REESS
Conversion
Vb
System
- -
V1
Electrical Chassis
6.15.2.4.1.deleted
2.2.3.2.added
Measure and record the voltage (V1) between the negative side of the high
voltage bus and the electrical chassis (see Figure 1).
6.15.2.4.2.deleted
2.2.3.3.added
Measure and record the voltage (V2) between the positive side of the high
voltage bus and the electrical chassis (see Figure 1).
ECE/TRANS/WP.29/2015/69
Annex 4A
6.15.2.4.3.deleted
2.2.3.4.added
If V1 is greater than or equal to V2, insert a standard known resistance (Ro)
between the negative side of the high voltage bus and the electrical chassis.
With Ro installed, measure the voltage (V1’) between the negative side of the
high voltage bus and the electrical chassis (see Figure 2).
Calculate the electrical isolation (Ri) according to the following formula:
Ri = Ro*(Vb/V1’ – Vb/V1) or Ri = Ro*Vb*(1/V1’ – 1/V1)
Figure 2added
Electrical Chassis
Energy Conversion
System Assembly REESS Assembly
High Voltage Bus
+ +
Energy
Traction System REESS
Conversion
Vb
System
- -
V1´ Ro
Electrical Chassis
If V2 is greater than V1, insert a standard known resistance (Ro) between the
positive side of the high voltage bus and the electrical chassis. With Ro installed,
measure the voltage (V2’) between the positive side of the high voltage bus and the
electrical chassis (see Figure 3). Calculate the electrical isolation (Ri) according to
the formula shown. Divide this electrical isolation value (in Ω) by the nominal
operating voltage of the high voltage bus (in Volts).
Calculate the electrical isolation (Ri) according to the following formula:
Ri = Ro*(Vb/V2’ – Vb/V2) or Ri = Ro*Vb*(1/V2’ – 1/V2)
Annex4A
Figure 3added
Electrical Chassis
Energy Conversion Ro
System Assembly REESS Assembly
V2'
High Voltage Bus
+ +
Energy
Conversion Traction System REESS
System
- -
Electrical Chassis
2.2.3.5.added
The electrical isolation value Ri (in Ω) divided by the working voltage of the
high voltage bus (in Volts) results in the isolation resistance (in Ω/V).
Note: The standard known resistance Ro (in Ω) should be the value of the
minimum required isolation resistance (in Ω/V) multiplied by the working
voltage of the vehicle plus/minus 20 per cent (in volts). Ro is not required to
be precisely this value since the equations are valid for any Ro; however, a
Ro value in this range should provide good resolution for the voltage
measurements.
Annex 4B
Annex 4B
Isolation resistance measurement method for component
based tests of a REESS
1.added
The isolation resistance measurement shall be conducted by selecting an
appropriate measurement method from among those listed in paragraphs 1.1.
through 1.2. of this annex, depending on the electrical charge of the live parts
or the isolation resistance, etc.
If the operating voltage of the tested-device (Vb, Figure 1) cannot be
measured (e.g. due to disconnection of the electric circuit caused by main
contactors or fuse operation) the test may be performed with a modified test
device to allow measurement of the internal voltages (upstream the main
contactors).
These modifications shall not influence the test results.
The range of the electrical circuit to be measured shall be clarified in
advance, using electrical circuit diagrams, etc. If the high voltage buses are
galvanically isolated from each other, isolation resistance shall be measured
for each electrical circuit.
Moreover, modification necessary for measuring the isolation resistance may
be carried out, such as removal of the cover in order to reach the live parts,
drawing of measurement lines, change in software, etc..
In cases where the measured values are not stable due to the operation of the
isolation resistance monitoring system, etc., necessary modification for
conducting the measurement may be carried out, such as stopping the
operation of the device concerned or removing it. Furthermore, when the
device is removed, it shall be proven, using drawings, etc., that it will not
change the isolation resistance b…
8.deleted
1.1.1.added
An isolation resistance test instrument capable of applying a DC voltage
higher than the nominal voltage of the tested-device shall be used.
1.1.2.added
An insulation resistance test instrument shall be connected between the live
parts and the ground connection. Then, the isolation resistance shall be
measured.
If the system has several voltage ranges (e.g. because of boost converter) in a
galvanically connected circuit and some of the components cannot withstand
the working voltage of the entire circuit, the isolation resistance between those
Annex 4B
components and the ground connection can be measured separately by applying
at least half of their own working voltage with those component disconnected.
1.2.1.added
The voltage level of the tested-device throughout the test shall be at least the
nominal operating voltage of the tested-device.
1.2.2.added
The voltmeter used in this test shall measure DC values and shall have an
internal resistance of at least 10 MΩ.
1.2.3.1.added
The voltage is measured as shown in Figure 1 and the operating voltage of
the tested-device (Vb, Figure 1) is recorded. Vb shall be equal to or greater
than the nominal operating voltage of the tested-device.
+
Tested-
Vb device
-
V2 V1
Ground
connection
1.2.3.2.added
Measure and record the voltage (V1) between the negative pole of the tested-
device and the ground connection (Figure 1).
12.1.deleted
1.2.3.3.added
Measure and record the voltage (V2) between the positive pole of the tested-
device and the ground connection (Figure 1).
12.2.deleted
1.2.3.4.added
If V1 is greater than or equal to V2, insert a standard known resistance
(Ro) between the negative pole of the tested-device and the ground
connection. With Ro installed, measure the voltage (V1’) between the
negative pole of the tested-device and the ground connection (see
Annex 4B
Calculate the electrical isolation (Ri) according to the following formula:
Ri = Ro*(Vb/V1’ – Vb/V1) or Ri = Ro*Vb*(1/V1’ – 1/V1)
+
Tested-
Vb device
-
R0 V1’
Ground
connection
If V2 is greater than V1, insert a standard known resistance (Ro) between the
positive pole of the tested-device and the ground connection. With Ro
installed, measure the voltage (V2’) between the positive pole of the tested-
device and the ground connection (see Figure 3).
Calculate the electrical isolation (Ri) according to the following formula:
Ri = Ro*(Vb/V2’ – Vb/V2) or Ri = Ro*Vb*(1/V2’ – 1/V2)
+
Tested-
Vb device
R0 -
V2’
Ground
connection
Annex 4B
12.3.deleted
1.2.3.5.added
The electrical isolation value Ri (in Ω) divided by the nominal voltage of the
tested-device (in Volts) results in the isolation resistance (in Ω/V).
Note 1: The standard known resistance Ro (in Ω) should be the value of the
minimum required isolation resistance (in Ω/V) multiplied by the nominal
voltage of the tested-device plus/minus 20 per cent (in volts). Ro is not
required to be precisely this value since the equations are valid for any Ro;
however, a Ro value in this range should provide good resolution for the
voltage measurements.
Annex 5
12.4.deleted
Annex 5added
resistance monitoring system
The function of the on-board isolation resistance monitoring system shall be confirmed by
the following method:
Insert a resistor that does not cause the isolation resistance between the terminal being
monitored and the electrical chassis to drop below the minimum required isolation
resistance value. The warning shall be activated.
Annex 6 – Part 1
Annex 6 - Part 1
Essential characteristics of road vehicles or systems
12.5.deleted
12.6.deleted
12.7.deleted
3.3.added
Description or drawing(s) or picture(s) of the REESS explaining:
1 Strike out what does not apply.
Annex 6 – Part 1
3.6.added
Description or drawing(s) or picture(s) of the installation of the REESS in the
4.added
Fuel Cell (if any)
6.3.deleted
8.1.added
Brief description of the power circuit components installation or drawings/
pictures showing the location of the power circuit components installation: ...
8.4.1.added
Systems’ SOC level(s) for which power reduction is activated, descriptions,
8.4.2.added
Descriptions for systems’ reduced power mode(s) and similar mode(s),
Annex 6 – Part 2
Annex 6 - Part 2
Essential characteristics of REESS
3.3.deleted
3.6.deleted
4.deleted
1.6.added
Description or drawing(s) or picture(s) of the installation of the REESS in the
Annex 6 – Part 3
Annex 6 - Part 3
Essential characteristics of road vehicles or systems with
chassis connected to electrical circuits
2.3.added
Electrical specification:
8.1.deleted
2.5.added
Description or drawing(s) or picture(s) of the installation of the RESSS in the
8.4.1.deleted
3.added
1 Strike out what does not apply.
8.4.2.deleted
Annex 7added
procedures of the REESS
1.added
This annex describes the procedure for the determination of hydrogen
emissions during the charge procedures of the REESS of all road vehicles,
according to paragraph 5.4. of this Regulation.
2.added
The hydrogen emission test (Figure 7.1 of the present annex) is conducted in
order to determine hydrogen emissions during the charge procedures of the
REESS with the charger. The test consists in the following steps:
(a) Vehicle/REESS preparation,
(b) Discharge of the REESS,
(c) Determination of hydrogen emissions during a normal charge,
(d) Determination of hydrogen emissions during a charge carried out with
the charger failure.
1.6.deleted
3.1.1.added
The vehicle shall be in good mechanical condition and have been driven
at least 300 km during seven days before the test. The vehicle shall be
equipped with the REESS subject to the test of hydrogen emissions, over this
period.
3.1.2.added
If the REESS is used at a temperature above the ambient temperature, the
operator shall follow the manufacturer's procedure in order to keep the
REESS temperature in normal functioning range.
The manufacturer's representative shall be able to certify that the temperature
conditioning system of the REESS is neither damaged nor presenting a
capacity defect.
3.2.1.added
The REESS shall be in good mechanical condition and have been subject to
minimum of 5 standard cycles (as specified in Annex 8, Appendix 1).
3.2.2.added
If the REESS is used at a temperature above the ambient temperature, the
operator shall follow the manufacturer's procedure in order to keep the
REESS temperature in its normal functioning range.
The manufacturer's representative shall be able to certify that the temperature
conditioning system of the REESS is neither damaged nor presenting a
capacity defect
Annex 7
Figure 7added
Determination of hydrogen emissions during the charge procedures of the REESS
START
Vehicle/REESS preparation
(if necessary)
Maximum 7 days
days days
Discharge of the REESS
Ambient temperature of 293 to 303 K
Maximum 15 min
12 to Soak
36 h
Maximum 2 min after
connection to mains
Hydrogen emission test
during a normal charge
Maximum 7 days
Discharge of the REESS
Ambient temperature of 293 to 303 K
Maximum 15 min
12 to Soak
36 h
Maximum 2 min after
connection to mains
Hydrogen emission test
during a charger failure
Ambient temperature 293 K ± 2 K
END
4.1.added
The hydrogen emission measurement enclosure shall be a gas-tight measuring
chamber able to contain the vehicle/REESS under test. The vehicle/REESS
shall be accessible from all sides and the enclosure when sealed shall be gas-
tight in accordance with Appendix 1 to this annex. The inner surface of the
enclosure shall be impermeable and non-reactive to hydrogen. The
temperature conditioning system shall be capable of controlling the internal
enclosure air temperature to follow the prescribed temperature throughout the
test, with an average tolerance of ±2 K over the duration of the test.
To accommodate the volume changes due to enclosure hydrogen emissions,
either a variable-volume or another test equipment may be used. The
variable-volume enclosure expands and contracts in response to the hydrogen
emissions in the enclosure. Two potential means of accommodating the
internal volume changes are movable panels, or a bellows design, in which
impermeable bags inside the enclosure expand and contract in response to
internal pressure changes by exchanging air from outside the enclosure. Any
design for volume accommodation shall maintain the integrity of the
enclosure as specified in Appendix 1 to this annex.
Any method of volume accommodation shall limit the differential between
the enclosure internal pressure and the barometric pressure to a maximum
value of ±5hPa.
The enclosure shall be capable of latching to a fixed volume. A variable
volume enclosure shall be capabl…
4.2.1.1.added
The atmosphere within the chamber is monitored using a hydrogen analyser
(electrochemical detector type) or a chromatograph with thermal conductivity
detection. Sample gas shall be drawn from the mid-point of one side-wall or
roof of the chamber and any bypass flow shall be returned to the enclosure,
preferably to a point immediately downstream of the mixing fan.
1.deleted
4.2.1.2.added
The hydrogen analyser shall have a response time to 90 per cent of final
reading of less than 10 seconds. Its stability shall be better than 2 per cent of
full scale at zero and at 80 per cent ± 20 per cent of full scale, over
a 15-minute period for all operational ranges.
2.deleted
4.2.1.3.added
The repeatability of the analyser expressed as one standard deviation shall be
better than 1 per cent of full scale, at zero and at 80 per cent ± 20 per cent of
full scale on all ranges used.
Figure 1deleted
4.2.1.4.added
The operational ranges of the analyser shall be chosen to give best resolution
over the measurement, calibration and leak checking procedures.
2.1.deleted
4.2.2.added
The hydrogen analyser shall be fitted with a device to record electrical signal
output, at a frequency of at least once per minute. The recording system shall
have operating characteristics at least equivalent to the signal being recorded and
Annex 7
shall provide a permanent record of results. The recording shall show a clear
indication of the beginning and end of the normal charge test and charging failure
operation.
1.deleted
2.deleted
4.3.1.added
The temperature in the chamber is recorded at two points by temperature
sensors, which are connected so as to show a mean value. The measuring
points are extended approximately 0.1 m into the enclosure from the vertical
centre line of each side-wall at a height of 0.9 ± 0.2 m.
4.3.2.added
The temperatures in the proximity of the cells are recorded by means of the
sensors.
2.1.1.deleted
4.3.3.added
Temperatures shall, throughout the hydrogen emission measurements, be
recorded at a frequency of at least once per minute.
2.1.2.deleted
4.3.4.added
The accuracy of the temperature recording system shall be within ±1.0 K and
the temperature shall be capable of being resolved to ±0.1 K.
4.3.5.added
The recording or data processing system shall be capable of resolving time
to ±15 seconds.
2.2.1.deleted
2.2.2.deleted
4.4.1.added
The difference p between barometric pressure within the test area and the
enclosure internal pressure shall, throughout the hydrogen emission
measurements, be recorded at a frequency of at least once per minute.
4.4.2.added
The accuracy of the pressure recording system shall be within ±2 hPa and the
pressure shall be capable of being resolved to ±0.2 hPa.
2.2.3.1.deleted
4.4.3.added
The recording or data processing system shall be capable of resolving time
to ±15 seconds.
2.2.3.2.deleted
2.2.3.3.deleted
4.5.1.added
The charger voltage and current intensity (battery) shall, throughout the
hydrogen emission measurements, be recorded at a frequency of at least once
per minute.
2.2.3.4.deleted
4.5.2.added
The accuracy of the voltage recording system shall be within ±1 V and the
voltage shall be capable of being resolved to ±0.1 V.
Figure 2deleted
4.5.3.added
The accuracy of the current intensity recording system shall be within ±0.5 A
and the current intensity shall be capable of being resolved to ±0.05 A.
Figure 3deleted
4.5.4.added
The recording or data processing system shall be capable of resolving time to
±15 seconds.
2.2.3.5.deleted
4.6.added
The chamber shall be equipped with one or more fans or blowers with a
possible flow of 0.1 to 0.5 m3/second in order to thoroughly mix the
atmosphere in the enclosure. It shall be possible to reach a homogeneous
temperature and hydrogen concentration in the chamber during
measurements. The vehicle in the enclosure shall not be subjected to a direct
stream of air from the fans or blowers.
1.deleted
4.7.1.added
The following pure gases shall be available for calibration and operation:
(a) Purified synthetic air (purity < 1 ppm C1 equivalent; < 1 ppm CO;
< 400 ppm CO2; < 0.1 ppm NO ); oxygen content between 18 and
21 per cent by volume,
(b) Hydrogen (H2 ), 99.5 per cent minimum purity.
1.1.1.deleted
4.7.2.added
Calibration and span gases shall contain mixtures of hydrogen (H 2) and
purified synthetic air. The real concentrations of a calibration gas shall be
within ±2 per cent of the nominal values. The accuracy of the diluted gases
obtained when using a gas divider shall be within ±2 per cent of the nominal
value. The concentrations specified in Appendix 1 may also be obtained by a
gas divider using synthetic air as the dilution gas.
1.1.2.deleted
5.added
The test consists in the five following steps:
(a) Vehicle/REESS preparation;
(b) Discharge of the REESS;
(c) Determination of hydrogen emissions during a normal charge;
(d) Discharge of the traction battery;
(e) Determination of hydrogen emissions during a charge carried out with
the charger failure.
If the vehicle/REESS has to be moved between two steps, it shall be pushed
to the following test area.
1.2.1.deleted
5.1.1.added
The ageing of REESS shall be checked, proving that the vehicle has
performed at least 300 km during seven days before the test. During this
period, the vehicle shall be equipped with the traction battery submitted to
the hydrogen emission test. If this cannot be demonstrated then the following
procedure will be applied.
1.2.2.deleted
5.1.1.1.added
The procedure starts with the discharge of the REESS of the vehicle while
driving on the test track at a steady speed of 70 per cent ± 5 per cent of the
maximum speed of the vehicle during 30 minutes.
Discharging is stopped:
(a) When the vehicle is not able to run at 65 per cent of the maximum
thirty minutes speed, or
(b) When an indication to stop the vehicle is given to the driver by the
standard on-board instrumentation, or
(c) After having covered the distance of 100 km.
Annex 7
5.1.1.2.added
The charge is carried out:
(a) With the charger;
(b) In an ambient temperature between 293 K and 303 K.
The procedure excludes all types of external chargers.
The end of REESS charge criteria corresponds to an automatic stop given by
the charger.
This procedure includes all types of special charges that could be
automatically or manually initiated like, for instance, the equalisation charges
or the servicing charges.
1.2.3.1.deleted
5.1.1.3.added
Procedure from paragraphs 5.1.1.1. and 5.1.1.2. shall be repeated two times.
1.2.3.2.deleted
5.1.2.added
The REESS is discharged while driving on the test track at a steady speed of
70 per cent ±5 per cent from the maximum thirty minutes speed of the
vehicle.
Stopping the discharge occurs:
(a) When an indication to stop the vehicle is given to the driver by the
standard on-board instrumentation, or
(b) When the maximum speed of the vehicle is lower than 20 km/h.
1.2.3.3.deleted
5.1.3.added
Within fifteen minutes of completing the battery discharge operation
specified in paragraph 5.2., the vehicle is parked in the soak area. The vehicle
is parked for a minimum of 12 hours and a maximum of 36 hours, between
the end of the traction battery discharge and the start of the hydrogen
emission test during a normal charge. For this period, the vehicle shall be
soaked at 293 K ± 2 K.
1.2.3.4.deleted
1.2.3.5.deleted
5.1.4.1.added
Before the completion of the soak period, the measuring chamber shall be
purged for several minutes until a stable hydrogen background is obtained.
The enclosure mixing fan(s) shall also be turned on at this time.
Annex 6deleted
5.1.4.2.added
The hydrogen analyser shall be zeroed and spanned immediately prior to the
test.
1.deleted
5.1.4.3.added
At the end of the soak, the test vehicle, with the engine shut off and the test
vehicle windows and luggage compartment opened shall be moved into the
measuring chamber.
2.deleted
5.1.4.4.added
The vehicle shall be connected to the mains. The REESS is charged
according to normal charge procedure as specified in paragraph 5.1.4.7.
below.
2.1.deleted
5.1.4.5.added
The enclosure doors are closed and sealed gas-tight within two minutes from
electrical interlock of the normal charge step.
2.2.deleted
5.1.4.6.added
The start of a normal charge for hydrogen emission test period begins when
the chamber is sealed. The hydrogen concentration, temperature and
barometric pressure are measured to give the initial readings C H2i, Ti and Pi
for the normal charge test.
These figures are used in the hydrogen emission calculation (paragraph 6. of
this annex). The ambient enclosure temperature T shall not be less than
291 K and no more than 295 K during the normal charge period.
Figure 1deleted
5.1.4.7.added
The normal charge is carried out with the charger and consists of the
following steps:
(a) Charging at constant power during t1;
(b) Over-charging at constant current during t2. Over-charging intensity
is specified by manufacturer and corresponds to the one used during
equalisation charging.
The end of REESS charge criteria corresponds to an automatic stop given by
the charger to a charging time of t1 + t2. This charging time will be limited to
t1 + 5 h, even if a clear indication is given to the driver by the standard
instrumentation that the battery is not yet fully charged.
2.3.deleted
5.1.4.8.added
The hydrogen analyser shall be zeroed and spanned immediately before the
end of the test.
5.1.4.9.added
The end of the emission sampling period occurs t1 + t2 or t1 + 5 hours after
the beginning of the initial sampling, as specified in paragraph 5.1.4.6. of this
annex. The different times elapsed are recorded. The hydrogen
concentration, temperature and barometric pressure are measured to give the
final readings CH2f, Tf and Pf for the normal charge test, used for the
calculation in paragraph 6. of this annex.
1.deleted
5.1.5.1.added
Within seven days maximum after having completed the prior test, the
procedure starts with the discharge of the REESS of the vehicle according to
paragraph 5.1.2. of this annex.
5.1.5.2.added
The steps of the procedure in paragraph 5.1.3. of this annex shall be repeated.
5.1.5.3.added
Before the completion of the soak period, the measuring chamber shall be
purged for several minutes until a stable hydrogen background is obtained.
The enclosure mixing fan(s) shall also be turned on at this time.
5.1.5.4.added
The hydrogen analyser shall be zeroed and spanned immediately prior to the
test.
5.1.5.5.added
At the end of the soak, the test vehicle, with the engine shut off and the test
vehicle windows and luggage compartment opened shall be moved into the
measuring chamber.
3.deleted
5.1.5.6.added
The vehicle shall be connected to the mains. The REESS is charged
according to failure charge procedure as specified in paragraph 5.1.5.9.
below.
4.deleted
5.1.5.7.added
The enclosure doors are closed and sealed gas-tight within two minutes from
electrical interlock of the failure charge step.
Annex 7
1.deleted
5.1.5.8.added
The start of a failure charge for hydrogen emission test period begins when
the chamber is sealed. The hydrogen concentration, temperature and
barometric pressure are measured to give the initial readings CH2i, Ti and Pi
for the failure charge test.
These figures are used in the hydrogen emission calculation (paragraph 6. of
this annex). The ambient enclosure temperature T shall not be less than
291 K and no more than 295 K during the charging failure period.
2.deleted
5.1.5.9.added
The charging failure is carried out with the suitable charger and consists of
the following steps:
(a) Charging at constant power during t'1;
(b) Charging at maximum current as recommended by the manufacturer
during 30 minutes. During this phase, the charger shall supply
maximum current as recommended by the manufacturer.
5.1.5.10.added
The hydrogen analyser shall be zeroed and spanned immediately before the
end of the test.
5.1.5.11.added
The end of test period occurs t'1 + 30 minutes after the beginning of the initial
sampling, as specified in paragraph 5.1.5.8. above. The times elapsed are
recorded. The hydrogen concentration, temperature and barometric pressure
are measured to give the final readings CH2f, Tf and Pf for the charging failure
test, used for the calculation in paragraph 6. of this annex.
2.deleted
5.2.1.added
The ageing of REESS shall be checked, to confirm that the REESS has
performed at least 5 standard cycles (as specified in Annex 8, Appendix 1).
5.2.2.added
The REESS is discharged at 70 per cent ±5 per cent of the nominal power of
the system.
Stopping the discharge occurs when minimum SOC as specified by the
manufacturer is reached.
3.1.1.deleted
5.2.3.added
Within 15 minutes of the end of the REESS discharge operation specified in
paragraph 5.2.2. above, and before the start of the hydrogen emission test, the
REESS shall be soaked at 293 K ± 2 K for a minimum period of 12 hours and
a maximum of period of 36 hours.
5.2.4.1.added
Before the completion of the REESS's soak period, the measuring chamber
shall be purged for several minutes until a stable hydrogen background is
obtained. The enclosure mixing fan(s) shall also be turned on at this time.
5.2.4.2.added
The hydrogen analyser shall be zeroed and spanned immediately prior to the
test.
5.2.4.3.added
At the end of the soak period, the REESS shall be moved into the measuring
chamber.
Figure 1deleted
5.2.4.4.added
The REESS shall be charged in accordance with the normal charge procedure
as specified in paragraph 5.2.4.7. below.
5.2.4.5.added
The chamber shall be closed and sealed gas-tight within two minutes of the
electrical interlock of the normal charge step.
4.1.deleted
5.2.4.6.added
The start of a normal charge for hydrogen emission test period shall begin
when the chamber is sealed. The hydrogen concentration, temperature and
barometric pressure are measured to give the initial readings C H2i, Ti and Pi
for the normal charge test.
These figures are used in the hydrogen emission calculation (paragraph 6. of
this annex). The ambient enclosure temperature T shall not be less than
291 K and no more than 295 K during the normal charge period.
5.2.4.7.added
The normal charge is carried out with a suitable charger and consists of the
following steps:
(a) Charging at constant power during t1;
(a) Over-charging at constant current during t2. Over-charging intensity is
specified by manufacturer and corresponding to that used during
equalisation charging.
The end of REESS charge criteria corresponds to an automatic stop given by
the charger to a charging time of t1 + t2. This charging time will be limited to
t1 + 5 h, even if a clear indication is given by a suitable instrumentation that
the REESS is not yet fully charged.
5.2.4.8.added
The hydrogen analyser shall be zeroed and spanned immediately before the
end of the test.
4.2.1.1.deleted
5.2.4.9.added
The end of the emission sampling period occurs t 1 + t2 or t1 + 5 h after the
beginning of the initial sampling, as specified in paragraph 5.2.4.6. above.
The different times elapsed are recorded. The hydrogen concentration,
temperature and barometric pressure are measured to give the final readings
CH2f, Tf and Pf for the normal charge test, used for the calculation in
paragraph 6. of this annex
4.2.1.2.deleted
4.2.1.3.deleted
5.2.5.1.added
The test procedure shall start within a maximum of seven days after having
completed the test in paragraph 5.2.4. above, the procedure shall start with
the discharge of the REESS of the vehicle in accordance with
paragraph 5.2.2. above.
4.2.1.4.deleted
5.2.5.2.added
The steps of the procedure in paragraph 5.2.3. above shall be repeated.
4.2.2.deleted
5.2.5.3.added
Before the completion of the soak period, the measuring chamber shall be
purged for several minutes until a stable hydrogen background is obtained.
The enclosure mixing fan(s) shall also be turned on at this time.
5.2.5.4.added
The hydrogen analyser shall be zeroed and spanned immediately prior to the
test.
4.3.1.deleted
5.2.5.5.added
At the end of the soak the REESS shall be moved into the measuring
chamber.
Annex 7
4.3.2.deleted
5.2.5.6.added
The REESS shall be charged according to the failure charge procedure as
specified in paragraph 5.2.5.9. below.
4.3.3.deleted
5.2.5.7.added
The chamber shall be closed and sealed gas-tight within two minutes from
electrical interlock of the failure charge step.
4.3.4.deleted
5.2.5.8.added
The start of a failure charge for hydrogen emission test period begins when
the chamber is sealed. The hydrogen concentration, temperature and
barometric pressure are measured to give the initial readings C H2i, Ti and Pi
for the failure charge test.
These figures are used in the hydrogen emission calculation (paragraph 6. of
this annex). The ambient enclosure temperature T shall not be less than
291 K and no more than 295 K during the charging failure period.
4.3.5.deleted
5.2.5.9.added
The charging failure is carried out with a suitable charger and consists of the
following steps:
(a) Charging at constant power during t'1,
(b) Charging at maximum current as recommended by the manufacturer
during 30 minutes. During this phase, the charger shall supply
maximum current as recommended by the manufacturer.
5.2.5.10.added
The hydrogen analyser shall be zeroed and spanned immediately before the
end of the test.
4.4.1.deleted
5.2.5.11.added
The end of test period occurs t'1 + 30 minutes after the beginning of the initial
sampling, as specified in paragraph 5.2.5.8. above. The times elapsed are
recorded. The hydrogen concentration, temperature and barometric pressure
are measured to give the final readings CH2f, Tf and Pf for the charging failure
test, used for the calculation in paragraph 6. below.
4.4.2.deleted
6.added
The hydrogen emission tests described in paragraph 5. above allow the
calculation of the hydrogen emissions from the normal charge and charging
failure phases. Hydrogen emissions from each of these phases are calculated
using the initial and final hydrogen concentrations, temperatures and
pressures in the enclosure, together with the net enclosure volume.
The formula below is used:
V
(1 out ) C H 2 f Pf C P
M H 2 k V 10
4 V H 2 i i
Tf Ti
Where:
MH2 = hydrogen mass, in grams
CH2 = measured hydrogen concentration in the enclosure, in ppm
volume
V = net enclosure volume in cubic metres (m3) corrected for the
volume of the vehicle, with the windows and the luggage
compartment open. If the volume of the vehicle is not
determined a volume of 1.42 m³ is subtracted.
Vout = compensation volume in m³, at the test temperature and
pressure
T = ambient chamber temperature, in K
P = absolute enclosure pressure, in kPa
k = 2.42
Where: i is the initial reading
f is the final reading
4.4.3.deleted
6.1.added
The hydrogen mass emissions for the REESS are:
MN = hydrogen mass emission for normal charge test, in grams
MD = hydrogen mass emission for charging failure test, in grams
Annex 7 - Appendix 1
4.5.1.deleted
1.added
All equipment shall be calibrated before its initial use and then calibrated as
often as necessary and in any case in the month before type approval testing.
The calibration methods to be used are described in this appendix.
4.5.2.deleted
4.5.3.deleted
4.5.4.deleted
2.1.1.added
Before its initial use, the internal volume of the chamber shall be determined
as follows:
The internal dimensions of the chamber are carefully measured, taking into
account any irregularities such as bracing struts.
The internal volume of the chamber is determined from these measurements.
The enclosure shall be latched to a fixed volume when the enclosure is held
at an ambient temperature of 293 K. This nominal volume shall be
repeatable within ±0.5 per cent of the reported value.
4.6.deleted
2.1.2.added
The net internal volume is determined by subtracting 1.42 m3 from the
internal volume of the chamber. Alternatively the volume of the test vehicle
with the luggage compartment and windows open or REESS may be used
instead of the 1.42 m3.
2.1.3.added
The chamber shall be checked as in paragraph 2.3. of this appendix. If the
hydrogen mass does not agree with the injected mass to within ±2 per cent
then corrective action is required.
4.7.1.deleted
2.2.added
This operation determines that the chamber does not contain any materials
that emit significant amounts of hydrogen. The check shall be carried out at
the enclosure's introduction to service, after any operations in the enclosure
which may affect background emissions and at a frequency of at least once
per year.
4.7.2.deleted
2.2.1.added
Variable-volume enclosure may be operated in either latched or unlatched
volume configuration, as described in paragraph 2.1.1. above. Ambient
temperature shall be maintained at 293 K ± 2 K, throughout the four-hour
period mentioned below.
5.deleted
2.2.2.added
The enclosure may be sealed and the mixing fan operated for a period of up
to 12 hours before the four-hour background-sampling period begins.
2.2.3.added
The analyser (if required) shall be calibrated, then zeroed and spanned.
5.1.1.deleted
2.2.4.added
The enclosure shall be purged until a stable hydrogen reading is obtained,
and the mixing fan turned on if not already on.
5.1.1.1.deleted
2.2.5.added
The chamber is then sealed and the background hydrogen concentration,
temperature and barometric pressure are measured. These are the initial
readings CH2i, Ti and Pi used in the enclosure background calculation.
5.1.1.2.deleted
2.2.6.added
The enclosure is allowed to stand undisturbed with the mixing fan on for a
period of four hours.
5.1.1.3.deleted
2.2.7.added
At the end of this time the same analyser is used to measure the hydrogen
concentration in the chamber. The temperature and the barometric pressure
are also measured. These are the final readings CH2f, Tf and Pf.
5.1.2.deleted
2.2.8.added
The change in mass of hydrogen in the enclosure shall be calculated over the
time of the test in accordance with paragraph 2.4. of this annex and shall not
exceed 0.5 g.
5.1.3.deleted
2.3.added
The calibration and hydrogen retention test in the chamber provides a check
on the calculated volume (paragraph 2.1. above) and also measures any leak
rate. The enclosure leak rate shall be determined at the enclosure's
introduction to service, after any operations in the enclosure which may
affect the integrity of the enclosure, and at least monthly thereafter. If six
consecutive monthly retention checks are successfully completed without
corrective action, the enclosure leak rate may be determined quarterly
thereafter as long as no corrective action is required.
2.3.1.added
The enclosure shall be purged until a stable hydrogen concentration is
reached. The mixing fan is turned on, if not already switched on. The
hydrogen analyser is zeroed, calibrated if required, and spanned.
5.1.4.1.deleted
2.3.2.added
The enclosure shall be latched to the nominal volume position.
5.1.4.2.deleted
2.3.3.added
The ambient temperature control system is then turned on (if not already on)
and adjusted for an initial temperature of 293 K.
5.1.4.3.deleted
2.3.4.added
When the enclosure temperature stabilizes at 293 K ± 2 K, the enclosure is
sealed and the background concentration, temperature and barometric
pressure measured. These are the initial readings CH2i, Ti and Pi used in the
enclosure calibration.
5.1.4.4.deleted
2.3.5.added
The enclosure shall be unlatched from the nominal volume.
5.1.4.5.deleted
2.3.6.added
A quantity of approximately 100 g of hydrogen is injected into the enclosure.
This mass of hydrogen shall be measured to an accuracy of ±2 per cent of the
measured value.
5.1.4.6.deleted
2.3.7.added
The contents of the chamber shall be allowed to mix for five minutes and
then the hydrogen concentration, temperature and barometric pressure are
measured. These are the final readings CH2f, Tf and Pf for the calibration of
the enclosure as well as the initial readings CH2i, Ti and Pi for the retention
check.
5.1.4.7.deleted
2.3.8.added
On the basis of the readings taken in paragraphs 2.3.4 and 2.3.7 above and
the formula in paragraph 2.4. below, the mass of hydrogen in the enclosure is
calculated. This shall be within ±2 per cent of the mass of hydrogen
measured in paragraph 2.3.6. above.
5.1.4.8.deleted
2.3.9.added
The contents of the chamber shall be allowed to mix for a minimum of
10 hours. At the completion of the period, the final hydrogen concentration,
temperature and barometric pressure are measured and recorded. These are
the final readings CH2f, Tf and Pf for the hydrogen retention check.
Annex 7 – Appendix 1
5.1.4.9.deleted
2.3.10.added
Using the formula in paragraph 2.4. below, the hydrogen mass is then
calculated from the readings taken in paragraphs 2.3.7 and 2.3.9. above. This
mass may not differ by more than 5 per cent from the hydrogen mass given
by paragraph 2.3.8. above.
2.4.added
The calculation of net hydrogen mass change within the enclosure is used to
determine the chamber's hydrocarbon background and leak rate. Initial and
final readings of hydrogen concentration, temperature and barometric
pressure are used in the following formula to calculate the mass change.
V
(1 out ) C H 2f Pf C P
M H 2 k V 10
4 V H 2i i
Tf Ti
Where:
MH2 = hydrogen mass, in grams
CH2 = measured hydrogen concentration into the enclosure, in ppm
volume
V = enclosure volume in cubic metres (m3) as measured in
paragraph 2.1.1. above.
Vout = compensation volume in m³, at the test temperature and
pressure
T = ambient chamber temperature, in K
P = absolute enclosure pressure, in kPa
k = 2.42
Where: i is the initial reading
f is the final reading
5.1.5.1.deleted
3.added
The analyser should be calibrated using hydrogen in air and purified
synthetic air. See paragraph 4.8.2. of Annex 7.
Each of the normally used operating ranges are calibrated by the following
procedure:
5.1.5.2.deleted
3.1.added
Establish the calibration curve by at least five calibration points spaced as
evenly as possible over the operating range. The nominal concentration of
the calibration gas with the highest concentrations to be at least 80 per cent of
the full scale.
5.1.5.3.deleted
3.2.added
Calculate the calibration curve by the method of least squares. If the
resulting polynomial degree is greater than three, then the number of
calibration points shall be at least the number of the polynomial degree plus
two.
5.1.5.4.deleted
3.3.added
The calibration curve shall not differ by more than two per cent from the
nominal value of each calibration gas.
5.1.5.5.deleted
3.4.added
Using the coefficients of the polynomial derived from paragraph 3.2. above, a
table of analyser readings against true concentrations shall be drawn by steps
no greater than 1 per cent of full scale. This is to be carried out for each
analyser range calibrated.
This table shall also contain other relevant data such as:
(a) Date of calibration;
(b) Span and zero potentiometer readings (where applicable);
(c) Nominal scale;
(d) Reference data of each calibration gas used;
(e) Real and indicated value of each calibration gas used together with the
percentage differences;
(f) Calibration pressure of analyser.
5.1.5.6.deleted
3.5.added
Alternative methods (e.g. computer, electronically controlled range switch)
can be used if it is proven to the technical service that these methods give
equivalent accuracy.
Annex 7 - Appendix 2
5.1.5.7.deleted
5.1.5.8.deleted
1.added
The family may be defined by basic design parameters which shall be
common to vehicles within the family. In some cases there may be
interaction of parameters. These effects shall also be taken into consideration
to ensure that only vehicles with similar hydrogen emission characteristics
are included within the family.
5.1.5.9.deleted
2.added
To this end, those vehicle types whose parameters described below are
identical are considered to belong to the same hydrogen emissions.
REESS:
(a) Trade name or mark of the REESS;
(b) Indication of all types of electrochemical couples used;
(c) Number of REESS cells;
(d) Number of REESS subsystems;
(e) Nominal voltage of the REESS (V);
(f) REESS energy (kWh);
(g) Gas combination rate (in per cent);
(h) Type(s) of ventilation for REESS subsystem(s);
(i) Type of cooling system (if any).
On-board charger:
(a) Make and type of different charger parts;
(b) Output nominal power (kW);
(c) Maximum voltage of charge (V);
(d) Maximum intensity of charge (A);
(e) Make and type of control unit (if any);
(f) Diagram of operating, controls and safety;
(g) Characteristics of charge periods.
5.1.5.10.deleted
Annex 8changed
5.1.5.11.deleted
1.changed
5.2.1.deleted
2.1.added
REESS subsystem(s) including the cells and their electrical connections. If
the manufacturer chooses to test with related subsystem(s), the manufacturer
shall demonstrate that the test result can reasonably represent the
performance of the complete REESS with respect to its safety performance
under the same conditions. If the electronic management unit for the REESS
is not integrated in the casing enclosing the cells, then the electronic
management unit may be omitted from installation on the tested-device if so
requested by the manufacturer.
5.2.2.deleted
2.2.added
The tested-device shall be firmly secured to the platform of the vibration
machine in such a manner as to ensure that the vibrations are directly
transmitted to the tested-device.
5.2.3.deleted
3.1.added
The following conditions shall apply to the tested-device:
(a) The test shall be conducted at an ambient temperature of 20 ± 10 °C;
(b) At the beginning of the test, the SOC shall be adjusted to a value in
the upper 50 per cent of the normal operating SOC range of the tested-
device;
(c) At the beginning of the test, all protection devices which affect the
function(s) of the tested-device that are relevant to the outcome of the
test shall be operational.
5.2.4.1.deleted
3.2.added
The tested-devices shall be subjected to a vibration having a sinusoidal
waveform with a logarithmic sweep between 7 Hz and 200 Hz and back to
7 Hz traversed in 15 minutes
This cycle shall be repeated 12 times for a total of 3 hours in the vertical
direction of the mounting orientation of the REESS as specified by the
manufacturer.
The correlation between frequency and acceleration shall be as shown in
5.2.4.2.deleted
Table 1added
Annex 8A
Frequency and acceleration (gross mass of tested-device less than 12 kg)
Frequency [Hz] Acceleration [m/s2]
7 - 18 10
18 - approximately 50 1) gradually increased from 10 to 80
50 - 200 80
5.2.4.3.deleted
Table 2added
Frequency [Hz] Acceleration [m/s2]
7 - 18 10
1)
18 - approximately 25 gradually increased from 10 to 20
25 - 200 20
1) The amplitude is then maintained at 0.8 mm (1.6 mm total excursion) and the
frequency is increased until the maximum acceleration as described in table 1 or
At the request of the manufacturer, a higher acceleration level as well as a
higher maximum frequency may be used.
At the request of the manufacturer a vibration test profile determined by the
vehicle-manufacturer, verified for the vehicle application and agreed with the
Technical Service may be used as a substitute for the frequency - acceleration
correlation of Table 1 or Table 2. The approval of a REESS tested according
to this condition shall be limited to approvals for a specific vehicle type.
After the vibration, a standard cycle as described in Annex 8, Appendix 1
shall be conducted, if not inhibited by the tested-device.
The test shall end with an observation period of 1 h at the ambient
temperature conditions of the test environment.
Annex 8B
Annex 8B
Thermal shock and cycling test
5.2.4.4.deleted
1.added
The purpose of this test is to verify the resistance of the REESS to sudden
changes in temperature. The REESS shall undergo a specified number of
temperature cycles, which start at ambient temperature followed by high and
low temperature cycling. It simulates a rapid environmental temperature
change which a REESS would likely experience during its life.
5.2.4.5.deleted
2.added
This test shall be conducted either with the complete REESS or with related
REESS subsystem(s) of the REESS including the cells and their electrical
connections. If the manufacturer chooses to test with related subsystem(s),
the manufacturer shall demonstrate that the test result can reasonably
represent the performance of the complete REESS with respect to its safety
performance under the same conditions. If the electronic management unit for
the REESS is not integrated in the casing enclosing the cells, then the
electronic management unit may be omitted from installation on the tested-
device if so requested by the manufacturer.
5.2.4.6.deleted
5.2.4.7.deleted
3.1.changed
5.2.4.8.deleted
3.2.changed
5.2.4.9.deleted
1.added
Simulates a mechanical impact load which may occur at an unintended drop
after REESS removal.
5.2.5.1.deleted
2.1.added
The following conditions shall apply to the removed REESS at the start of
the test:
(a) Adjust the SOC to at least 90 per cent of the rated capacity as
specified in the Annex 6, Part 1, paragraph 3.4.3. or Annex 6, Part 2,
paragraph 1.4.3. or Annex 6, Part 3, paragraph 2.3.2.
(b) The test shall be performed at 20° C ± 10° C
5.2.5.2.deleted
2.2.added
Free fall of the removed REESS from a height of 1.0 m (from bottom of the
REESS) to a smooth, horizontal concrete pad or other flooring type with
equivalent hardness.
The removed REESS shall be dropped six times from different orientations
as decided by the Technical Service. The manufacturer may decide to use a
different removed REESS for each drop.
Directly after the termination of the drop test a standard cycle as described in
Annex 8, Appendix 1 shall be conducted, if not inhibited.
The test shall end with an observation period of 1 h at the ambient
temperature conditions of the test environment.
Annex 8D
Annex 8D
Mechanical shock
5.2.5.3.deleted
1.added
The purpose of this test is to verify the safety performance of the REESS
under mechanical shock which may occur during fall on the side from
stationary or parked situation.
5.2.5.4.deleted
5.2.5.5.deleted
2.1.added
This test shall be conducted either with the complete REESS or with related
subsystems of the REESS including the cells and their electrical connections.
If the manufacturer chooses to test with related subsystem(s), the
manufacturer shall demonstrate that the test result can reasonably represent
the performance of the complete REESS with respect to its safety
performance under the same conditions.
If the electronic management unit for the REESS is not integrated, then such
a control unit may be omitted from installation on the Tested-Device if so
requested by the manufacturer.
5.2.5.6.deleted
2.2.added
The Tested-Device shall be connected to the test fixture only by the intended
mountings provided for the purpose of attaching the REESS or REESS
subsystem to the vehicle.
5.2.5.7.deleted
5.2.5.8.deleted
3.1.added
General test conditions and requirements.
The following condition shall apply to the test:
(a) The test shall be conducted at an ambient temperature of
20 °C ± 10 °C.
(b) At the beginning of the test, the SOC shall be adjusted to a value in
the upper 50 per cent of the normal operating SOC range.
(c) At the beginning of the test, all protection devices which effect the
function of the tested-device and which are relevant to the outcome of
the test, shall be operational.
5.2.5.9.deleted
3.2.added
The tested-device shall be secured to the testing machine by means of a rigid
mount which will support all mounting surfaces of the tested-device.
The tested-device with
(a) A gross mass of less than 12 kg shall be subjected to a half-sine shock
of peak acceleration of 1,500 m/s2 and pulse duration of
6 milliseconds.
(b) A gross mass of 12 kg or more shall be subjected to a half-sine shock
of peak acceleration of 500 m/s2 and pulse duration of
11 milliseconds.
Annex 8D
For both the tested-device shall be subjected to three shocks in the positive
direction followed by three shocks in the negative direction of each three
mutually perpendicular mounting positions of the tested-device for a total of
18 shocks.
Directly after the termination of the mechanical shock test a standard cycle as
described in Annex 8, Appendix 1 shall be conducted, if not inhibited.
The test shall end with an observation period of 1 h at the ambient
temperature conditions of the test environment.
Annex 8E
Annex 8E
Fire resistance
5.2.5.10.deleted
1.added
The purpose of this test is to verify the resistance of the REESS, against
exposure to fire from outside of the vehicle due to e.g. a fuel spill from a
vehicle (either the vehicle itself or a nearby vehicle). This situation should
leave the driver and passengers with enough time to evacuate.
5.2.5.11.deleted
6.deleted
2.1.added
REESS subsystem(s) including the cells and their electrical connections. If
the manufacturer chooses to test with related subsystem(s), the manufacturer
shall demonstrate that the test result can reasonably represent the
performance of the complete REESS with respect to its safety performance
under the same conditions. If the electronic management unit for the REESS
is not integrated in the casing enclosing the cells, then the electronic
management unit may be omitted from installation on the tested-device if so
requested by the manufacturer. Where the relevant REESS subsystems are
distributed throughout the vehicle, the test may be conducted on each
relevant of the REESS subsystem.
6.1.deleted
3.1.added
The following requirements and conditions shall apply to the test:
(a) The test shall be conducted at a temperature of at least 0 °C;
(b) At the beginning of the test, the SOC shall be adjusted to a value in
the upper 50 per cent of the normal operating SOC range;
(c) At the beginning of the test, all protection devices which effect the
function of the tested-device and are relevant for the outcome of the
test shall be operational.
1.deleted
3.2.added
A vehicle based test or a component based test shall be performed at the
discretion of the manufacturer:
3.2.1.changed
The REESS tested-device shall be mounted in good mechanical condition and have been subject a testing fixture simulating actual mounting conditions as far as possible; no combustible material should be used for this with the exception of material that is part of the REESS. The method whereby the tested-device is fixed in the fixture shall correspond to minimum the relevant specifications for its installation in a vehicle. In the case of 5 standard cycles (as specified a REESS designed for a specific vehicle use, vehicle parts which affect the course of the fire in any way shall be taken into consideration. Annex 9, Appendix 1). 8E
3.2.2.added
The tested-device shall be placed on a grating table positioned above the pan,
in an orientation according to the manufacturer’s design intent.
The grating table shall be constructed by steel rods, diameter 6-10 mm, with
4-6 cm in between. If needed the steel rods could be supported by flat steel
parts.
2.1.1.deleted
3.3.added
The flame to which the tested-device is exposed shall be obtained by burning
commercial fuel for positive-ignition engines (hereafter called "fuel") in a
pan. The quantity of fuel shall be sufficient to permit the flame, under free-
burning conditions, to burn for the whole test procedure.
The fire shall cover the whole area of the pan during whole fire exposure.
The pan dimensions shall be chosen so as to ensure that the sides of the
tested-device are exposed to the flame. The pan shall therefore exceed the
horizontal projection of the tested-device by at least 20 cm, but not more than
50 cm. The sidewalls of the pan shall not project more than 8 cm above the
level of the fuel at the start of the test.
2.1.2.deleted
3.4.added
The pan filled with fuel shall be placed under the tested-device in such a way
that the distance between the level of the fuel in the pan and the bottom of the
tested-device corresponds to the design height of the tested-device above the
road surface at the unladen mass if paragraph 3.2.1. above is applied or
approximately 50 cm if paragraph 3.2.2. above is applied. Either the pan, or
the testing fixture, or both, shall be freely movable.
2.1.3.deleted
3.5.added
During phase C of the test, the pan shall be covered by a screen. The screen
shall be placed 3 cm ± 1 cm above the fuel level measured prior to the
ignition of the fuel. The screen shall be made of a refractory material, as
prescribed in Annex 8E - Appendix 1. There shall be no gap between the
bricks and they shall be supported over the fuel pan in such a manner that the
holes in the bricks are not obstructed. The length and width of the frame shall
be 2 cm to 4 cm smaller than the interior dimensions of the pan so that a gap
of 1 cm to 2 cm exists between the frame and the wall of the pan to allow
ventilation. Before the test the screen shall be at least at the ambient
temperature. The firebricks may be wetted in order to guarantee repeatable
test conditions.
2.2.deleted
3.6.added
If the tests are carried out in the open air, sufficient wind protection shall be
provided and the wind velocity at pan level shall not exceed 2.5 km/h.
2.2.1.deleted
2.2.2.deleted
2.2.3.deleted
2.2.4.deleted
2.2.5.deleted
2.2.6.deleted
2.2.7.deleted