Compare versions of UN R19

Power-driven vehicle front fog lamps

104 changed · 20 added · 36 deleted
Introductionchanged
This Regulation1 applies to front fog lamps, which may incorporate lenses of glass or plastic material. It incorporates two distinct classes. The original front fog lamp, Class "B" since inception, has been updated to incorporate the angular coordinate system with an amendment to the values in the relevant photometric table. With this class, only light sources as specified in UN Regulation No. 37 are allowed. The Class "F3" is designed to increase photometric performance. In particular the beam width and the minimum luminous intensities below the H-H line (paragraph 6.4.3. of this Regulation) have been increased whilst controls on the maximum intensity in the foreground are introduced. Above the H-H line, the intensity of the veiling light is reduced to improve visibility. Additionally this class may provide adaptive beam patterns where the performance is varied according to the visibility conditions. The introduction of the Class "F3" provides for requirements that are amended to be similar to those of a headlamp as follows: (a) The photometric values are specified as luminous intensities using the angular coordinate system; (b) Light sources can be selected according to the provisions of UN Regulation No. 37 (Incandescent filament (Filament light sources) and UN Regulation No. 99 (gas (Gas discharge light sources). Light emitting diode Emitting Diode (LED) modules and distributed lighting systems may also be used. (c) The cut-off and the gradient definitions. The photometric requirements permit the use of asymmetrical beam distributions. Scope This Regulation applies to front fog lamps for vehicles of categories L3, L4, L5, L7, M, N, and T.2
1.1.changed
The definitions given in UN Regulation No. 48 and its series of amendments in force at the time of application for type approval shall apply to this Regulation. Nothing in this Regulation shall prevent a Party to the Agreement applying this Regulation from prohibiting the combination of a front fog lamp incorporating a plastic lens, approved under this Regulation, with a mechanical headlamp-cleaning device (with wipers). As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.2, para. 2.
1.3.changed
"Coating" means any product or products applied in one or more layers to the outer face of a lens; 1 Nothing in this Regulation shall prevent a Party to the Agreement applying this Regulation from prohibiting the combination of a front fog lamp incorporating a plastic lens, approved under this Regulation, with a mechanical headlamp-cleaning device (with wipers). 2 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2. - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
1.4.1.changed
The trade name or mark; mark: (a) Lamps bearing the same trade name or mark but produced by different manufacturers shall be considered as being of different types; (b) Lamps produced by the same manufacturer differing only by the trade name or mark shall be considered as being of the same type.
1.4.3.changed
The characteristics of the optical system; (basic optical design, type / category type/category of light source, LED module, DLS etc.);
1.4.5.changed
The category of filament lamp(s) used, as listed in UN Regulation No. 37 , 37, UN Regulation No. 99 and/or the LED module or light generator specific identification code (s) code(s) (if applicable);
1.5.changed
"Colour of the light emitted from the device". The definitions of the colour of the light emitted, given in UN Regulation No. 48 and its series of amendments in force at the time of application for type approval, shall apply to this Regulation.
1.6.changed
References made in this Regulation to standard (étalon) light sources and to UN Regulations Nos. 37 and 99 shall refer to UN Regulations Nos. 37 and 99 and their series of amendments in force at the time of application for type approval.
2.3.1.changed
A brief technical specification including the category of filament lamp used as listed in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval, even if the filament lamp cannot be replaced;
2.4.1.changed
A brief technical specification including the category of the light source(s) used; this (these) light source category(ies) shall be listed in UN Regulation No. 37 or UN Regulation No. 99 and their series of amendments in force at the time of application for type approval, even if the light source cannot be replaced.
2.4.2.changed
In the case of LED module(s) or a light generator, module(s), the specific identification code of the module shall be stated. The drawing shall contain sufficient details to identify it and the position intended for the specific identification code and the trademark of the applicant.
2.4.4.changed
If the front fog lamp is fitted with LED module(s) or a distributed lighting system, module(s), a brief technical specification shall be provided. This information shall include the part number assigned by the light source manufacturer, a drawing with dimensions and the basic electrical and photometric values, an indication whether the light source complies with the UV-radiation requirements of paragraph 4.6. of Annex 12 to this Regulation, an official test report related to paragraph 5.9. 5.8. of this Regulation and the objective luminous flux.
2.4.5.changed
In the case of LED module(s) and if no provisions are taken to shield the relevant front fog lamp components made of plastic material from UV-radiation of light sources, e.g. by UV-retaining glass filters: One sample of each of the relevant materials. This shall have similar geometry to that a distributed lighting system is used, which part(s) is (are) to be intended to provide of the front fog beam by this system. In addition, a brief technical specification includes lamp being tested. Each material sample shall have the list of same appearance and surface treatment, if any, as intended for use in the light-guide(s) and related optical components and information describing the light-generator(s) sufficient front fog lamp to permit identification. This information shall include the part number assigned by the light-generator manufacturer, a drawing with dimensions and the basic electrical and photometric values and an official test report related to paragraph 5.9. of this Regulation. be approved.
2.4.6.changed
In the case where of an approval of a gas discharge light source is used: front fog lamp containing plastic lenses and/or having inner optical parts made from plastic, which have already been tested: The materials making up the lenses, coatings or optical inner parts, if any, shall be accompanied by the test report(s) on material testing against UV- radiation.
2.4.7.changed
In Two samples of each type of front fog lamp, one sample intended for the case installation on the left side of LED module(s) the vehicle and one sample intended for the installation on the right side of the vehicle; or a distributed lighting system and if no provisions are taken to shield the relevant matched pair of front fog lamp or distributed lighting system components made of plastic material from UV-radiation of (gas-discharge) light sources, e.g. by UV-retaining glass filters: One sample of each of the relevant materials. This shall have similar geometry to that of the front fog lamp or distributed lighting system being tested. Each material sample shall have the same appearance and surface treatment, if any, as intended for use in the front fog lamp to be approved. lamps.
2.4.6.1.deleted
And the ballast is not integrated with the light source, one ballast, which may be totally or partly integrated in the front fog lamp.
2.4.8.changed
In the case of an approval of a front fog lamp according to this paragraph and/or according to paragraph 5.10. containing plastic lenses and/or having inner optical parts made from plastic, which have already been tested: The materials making up the lenses, coatings or optical inner parts, One light source control gear, if any, shall be accompanied by the test report(s) on material testing against UV- radiation. applicable.
2.4.6.2.deleted
For approval of a distributed lighting system using a non-replaceable gas- discharge light source not approved under Regulation No. 99, two samples of the system including the light-generator and one ballast of each type shall be used, where applicable.
2.4.9.changed
Two samples of each type of front fog lamp, one sample intended for the installation on the left side of the vehicle and one sample intended for the installation on the right side of the vehicle; One variable intensity control or a matched pair of front fog lamps. generator providing the same signals, if applicable.
2.6.added
In the case of a type of lamp differing only by the trade name or mark from a type that has already been approved it shall be sufficient to submit:
2.6.1.added
A declaration by the lamp manufacturer that the type submitted is identical (except in the trade name or mark) with and has been produced by the same manufacturer as the type already approved, the latter being identified by its approval code;
2.4.10.deleted
One light source control gear, if applicable.
2.6.2.added
Two samples bearing the new trade name or mark or equivalent documentation.
2.4.11.deleted
One variable intensity control or a generator providing the same signals, if applicable.
3.1.changed
The samples of a type of front Front fog lamp or distributed lighting system lamps which are submitted for approval shall clearly, legibly and indelibly bear: (a) The trade name or mark of the applicant; (b) Marking indicating the class of the front fog lamp; And in case of Class F3 front fog lamps: (c) The LED module or light generator specific identification code, if any.
3.3.changed
The approval marking shall be placed on an inner or outer part (transparent or not) of the device which cannot be separated from the transparent part of the device emitting light; in the case of a distributed lighting system with outer lens built in the light-guide, this condition is deemed satisfied if the approval marking is placed at least on the light-generator and on the light-guide or on its protective shield. light. In any case the marking shall be visible when the device is fitted on the vehicle, at least when a movable part such as the hood or boot lid or a door is opened.
3.4.changed
In case of Class F3 front fog lamps: lamps with LED module(s) the lamp shall bear the marking of the rated voltage, rated wattage and the light source module specific identification code.
3.4.1.deleted
In case of a distributed lighting system, the light-generator(s) shall bear the marking of the rated voltage and wattage and in the case that the electronic control gear is not part of the device the light-generator(s) shall bear the trade name or mark of its manufacturer and the part number.
3.5.2.changed
Shall bear the specific identification code of the module; this marking must be clearly legible and indelible. 3 If the lens cannot be detached from the main body of the front fog lamp, a space on the lens or body shall be sufficient. The specific identification code shall comprise the starting letters "MD" for "Module" followed by the approval marking without the circle as prescribed in paragraph 4.2.1. below; this specific identification code shall be shown in the drawings mentioned in paragraph 2.2.1. of this Regulation and in the case where several non-identical LED modules are used, followed by additional symbols or characters. The approval marking does not have to be the same as the one on the lamp in which the module is used, but both markings shall be from the same applicant.
3.4.2.deleted
In case of lamps with LED module(s) the lamp shall bear the marking of the rated voltage, rated wattage and the light source module specific identification code.
3.5.3.added
If the LED module(s) are non-replaceable, the markings for LED module(s) are not required.
3.6.changed
If a light source control gear is used, which is not part of the LED module it shall be marked with its specific identification code(s), the rated input voltage and wattage. If the lens cannot be detached from the main body of the front fog lamp, a space on the lens or body shall be sufficient.
4.1.3.changed
An approval number shall be assigned to each type approved. Its first two digits (at present 04) 04)4 shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party may not assign the same number to another type of front fog lamp covered by this Regulation except in the case of an extension of the approval to a device differing only in the colour of the light emitted.
4.2.1.changed
An international approval marking, comprising of: 4 The 05 series of amendments does not require changes in the approval number (TRANS/WP.29/815, para. 82).
4.2.1.1.changed
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval4; approval;5 and;
4.2.2.1.changed
On front fog lamps meeting the requirements of this Regulation, in the case of: (a) Class B; the letter "B"; (b) Class F3; the symbol "F3". The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document TRANS/WP.29/78/Rev.2/Amend.3.
4.2.2.4.changed
The reciprocal lamp incorporation of passing-beam lamp and front fog lamp is possible if it is in compliance with UN Regulation No. 48.
4.2.2.6.changed
The two digits of the approval number (at present 04) 04)4 which indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval may be marked close to the above additional symbols.
4.3.1.changed
5 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.6, Annex 3) www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html Annex 3 to this Regulation gives examples of arrangements of the approval mark with the above-mentioned additional symbols.
5.added
The requirements contained in sections 5. "General specifications" and 6. "Individual specifications" and in the Annexes referenced in the said sections of UN Regulations Nos. 48, 53 or 86, and their series of amendments in force at the time of application for the lamp type approval shall apply to this Regulation. The requirements pertinent to each lamp and to the category/ies of vehicle on which the lamp is intended to be installed shall be applied, where its verification at the moment of lamp type approval is feasible.
5.6.changed
In the case of Class B, the front fog lamp shall only be equipped with one filament lamp light source approved according to UN Regulation No. 37 37, even if the filament lamp light source cannot be replaced. Any UN Regulation No. 37 approved filament lamp light source may be used provided that; (a) Its objective luminous flux does not exceed 2,000 lumens, and (b) No restriction on the use is made in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval.
5.6.1.changed
Even if this filament lamp light source cannot be replaced it shall comply with the requirements in paragraph 5.6. above.
5.7.changed
In the case of Class F3, irrespective of whether the light sources can be replaced or not, they the front fog lamp shall be: only be equipped with:
5.7.1.1.changed
UN Regulation No. 37 and its series of amendments in force at the time of application for type approval, provided that no restriction on their use is made , made,
5.7.1.2.changed
Or, UN Regulation No. 99 and its series of amendments in force at the time of application for type approval,
5.7.2.changed
And/or, one or more LED modules where the requirements of Annex 12 to this Regulation shall apply; compliance with these requirements shall be tested, tested.
5.8.changed
In the case of LED module or light generator module(s) it shall be checked, checked that:
5.8.1.changed
The design of the LED module(s) or light generator(s) shall be such that they can be fitted in no position other than the correct one.
5.7.3.deleted
And/or light generators where the requirements of Annex 12 to this Regulation shall apply. The compliance with the requirements shall be tested.
5.8.3.changed
The LED module(s) or light generator(s) shall be tamperproof.
5.9.changed
In case of front fog lamps with light source(s) having a total objective luminous flux that exceeds 2,000 lumens, a reference shall be made in item 10.8. 10. of the communication form in of Annex 1.
5.10.changed
If the lens of the front fog lamp is made of plastic material materials, tests shall be done according to the requirements in of Annex 6.
5.10.2.changed
The test in paragraph 5.11.1. above 5.10.1. is not necessary if low-UV type light sources as specified in UN Regulation No. 99 or in Annex 12 to this Regulation are used, or if provisions are taken, to shield the relevant lamp components from UV radiation, e.g. by glass filters.
5.11.changed
The front fog lamp and its ballast system or of light source control gear shall not generate radiated or power line disturbances, which cause a malfunction of other electric/electronic systems of the vehicle.5 vehicle:6
6.2.changed
The luminous intensity produced by the front fog lamp shall be measured at 25 m distance by means of a photoelectric cell having a useful area comprised within a square of 65 mm side. The point HV is the centre-point of the coordinate system with a vertical polar axis. Line h is the horizontal through HV (see Annex 4 to this Regulation). 6 Compliance with the requirements for electromagnetic compatibility is relevant to the vehicle type.
6.3.1.changed
A colourless standard (étalon) filament lamp as specified in Regulation No. 37, of the category specified by the manufacturer, which may be supplied by the manufacturer or applicant, shall be used.
6.3.1.1.changed
During the testing of the front fog lamp the power supply for this filament lamp shall be regulated so as to obtain the reference luminous flux at 13.2 V as indicated in the relevant data sheet of UN Regulation No. 37.
6.4.1.1.1.changed
The front fog lamp shall comply with the requirements of paragraph 6.4.3. of this Regulation with at least one complete set of appropriate standard (étalon) lamps, which may be supplied by the manufacturer or applicant. In the case of filament lamps operating directly under vehicle voltage system conditions: The front fog lamp shall be checked by means of colourless standard (etalon) filament lamps as specified in UN Regulation No. 37. During the testing of the front fog lamp, the power supply to the filament lamp(s) shall be regulated so as to obtain the reference luminous flux at 13.2 V as indicated on the relevant data sheet of UN Regulation No. 37.
6.4.1.2.changed
In the case of a gas-discharge light source: A standard light source shall be used as specified in UN Regulation No. 99, which has been aged during at least 15 cycles, in accordance with paragraph 4. of Annex 4 to UN Regulation No. 99. During testing of the front fog lamp the voltage at the terminals of the ballast or at the terminals of the light source in case the ballast is integrated with the light source shall be regulated to maintain 13.2 V for a 12 V system, or at the vehicle voltage as specified by the applicant, with a tolerance of ±0.1 V. The objective luminous flux of the gas-discharge light source may differ from that specified in UN Regulation No. 99. In this case, the luminous intensity values shall be corrected accordingly.
6.4.1.5.changed
Compliance with the requirement in requirements of paragraph 5.9.1. of this Regulation 5.8.1. shall be verified at least with respect to the values in line lines 3 and 4 of the table in of paragraph 6.4.3. below.
6.4.3.changed
When so adjusted, the front fog lamp shall meet the photometric requirements in the table below (refer also to paragraph 2.2. of Annex 4 to this Regulation): Vertical position* Horizontal position* Luminous Designated lines or zones above h + left of v: - Luminous intensity zones To comply below h - right of v: + (in cd) To comply Point 1, 2** +60° ±45° Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° 60 85 max All points Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 90 130 max All line Line 2** +4° -26° to +26° 105 150 max All line Line 3 +2° -26° to +26° 170 245 max All line Line 4 +1° -26° to +26° 250 360 max All line Line 5 0° -10° to +10° 340 485 max All line Line 6*** 6 *** -2.5° -10° to +10° 2,700 2,000 min All line < 50 per cent Line 7*** 7 *** -6.0° -10° to +10° < 50 % of max. on All line line 6 All line One or more Line 8L and R*** -1.5° to -3.5° -22° and +22° 800 1,100 min points One or more points Vertical position* Horizontal position* Designated lines or above h + left of v: - Luminous intensity zones below h - right of v: + (in cd) To comply Line 9L and R*** -1.5° to -4.5° -35° and +35° 320 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 8,400 12,000 max Whole zone * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.4. below. *** See paragraph 6.4.3.2. below.
8.changed
The discomfort dazzle caused by the front fog lamp shall be determined.6 determined.7
9.2.changed
Confirmation or refusal of approval, specifying the alterations, shall be communicated by the procedure specified in paragraph 4.1.4. of this Regulation to the Parties to the Agreement which apply this Regulation. This determination will be the subject of a recommendation to Type Approval Authorities.
10.1.changed
Front fog lamps approved under this Regulation shall be so manufactured as to conform to the type approved by meeting under this Regulation. The compliance with the requirements set forth in paragraphs 6. and 7. of this Regulation and in Annex 7. above shall be verified as follows:
10.1.1.added
The minimum requirements for Conformity of Production (CoP) control procedures set forth in Annex 7 to this Regulation shall be complied with.
10.1.2.added
The minimum requirements for sampling by an inspector set forth in Annex 8 to this Regulation shall be complied with.
10.3.changed
The holder of the approval shall in particular: 7 This determination will be the subject of a recommendation to Type Approval Authorities.
13.changed
Names and addresses of Technical Services responsible for conducting approval tests, and of Type Approval Authorities The Contracting Parties to the 1958 Agreement which apply this Regulation shall communicate to the United Nations Secretariat the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, or production definitively discontinued, issued in other countries, are to be sent.
14.1.changed
As from the date of entry into force of the 04 series of amendments (9 December 2010) no Regulation No. 149, Contracting Party Parties applying this Regulation shall refuse cease to grant type approval under approvals to this Regulation as amended by the 04 series of amendments. Regulation.
14.2.changed
As from the date of entry into force of Supplement 2 to the 04 series of amendments, Contracting Parties applying this Regulation shall not refuse to grant approvals for new types extensions of Class B front fog lamps. However, Contracting Parties applying approval to this Regulation, shall continue to issue approvals for Class B front fog lamps on the basis of the 02 and 03 any previous series of amendments provided that these front fog lamps are only intended as replacements for fitting to vehicles in use. of this Regulation.
14.3.changed
Until 60 months from the date of entry into force of the 04 series of amendments (9 December 2015) with regard to the changes introduced by the 04 series of amendments concerning the photometric testing at reference luminous flux at approximately 13.2 volts, and in order to allow the Technical Services to update their testing equipment, no Contracting Party Parties applying this Regulation shall refuse continue to grant approvals under for devices on basis of this Regulation as amended by the 04 and any previous series of amendments where existing testing equipment is used, with suitable conversion of to this Regulation, provided that the values devices are intended as replacements for fitting to the satisfaction of the Type Approval Authority responsible for type approval. vehicles in use.
14.4.changed
Existing approvals Contracting Parties applying this Regulation shall continue to allow fitting or use on a vehicle in use of a device approved to this Regulation as amended by any previous series of amendments, provided that the device is intended for front fog lamps already granted under the preceding replacement. 8 The 05 series of amendments to this Regulation shall remain valid indefinitely. does not require changes in the approval number (TRANS/WP.29/815, para. 82). Annex 1
Annex 1changed
(Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of front fog lamp pursuant to UN Regulation No. 19
10.1.changed
Class as described by the relevant marking: Distinguishing number of the country which has granted/refused/withdrawn approval (see approval provisions in the Regulation). Strike out which does not apply.
14.5.deleted
As from 60 months after the date of entry into force of the 03 series of amendments (11 July 2013), Contracting Parties applying this Regulation shall refuse to grant any extensions of approvals for all Class B front fog lamps except those intended as replacements for fitting to vehicles in use. Contracting Parties applying this Regulation shall continue to grant extensions of approvals for all Class F3 front fog lamps. Annex 1
10.3.added
LED module(s): yes/no2 and for each LED module a statement whether it is replaceable or not: yes/no2 1 Distinguishing number of the country which has granted/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out which does not apply.
10.5.added
In the case of an electronic light source control gear not being part of the lamp:
10.7.added
Luminous flux of the light source (see paragraph 5.9.) greater than 2,000 lumens: … yes/no2
10.6.deleted
In the case of an electronic light source control gear not being part of the lamp:
10.8.deleted
Luminous flux of the light source (see paragraph 5.9.) greater than 2,000 lumens: … yes/no2
17.changed
The list of documents deposited with the Type Approval Authority, which has granted approval, is annexed to this communication and may be obtained on request. 3 The voltage specifications shall include the tolerances or voltage range as specified by the manufacturer and verified by this approval. 4 The parameters of the input voltage including duty cycle, frequency, pulse shape and peak voltage shall be included. Annex 2
1.2.changed
For the periodic records, the reading is limited to points B501 B50 1 and left and right bottom corners of zone D (see Figure 2 in Annex 4).
2.3.changed
For the measured values in the table according to paragraph 6.4.3. of this Regulation the respective maximum deviations may be: Vertical position* Horizontal position* Luminous intensity candela Designated lines or above h + left of v: - To comply zones Equivalent Equivalent below h - right of v: + 20 per cent 30 per cent Point 1, 2** +60° ±45° 115 max 130 max Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° All points Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 160 max 170 max All line Line 2** +4° -26° to +26° 180 max 195 max All line Line 3 +2° -26° to +26° 295 max 320 max All line Line 4 +1° -26° to +26° 435 max 470 max All line Line 5 0° -10° to +10° 585 max 630 max All line from 5° inwards Line 6*** -2.5° 1,890 min All line to 10° outwards 2,160 min Line 8 One or more -1.5° to -3.5° -22° and +22° 880 min 770 min points L and R*** 1 The point B 50 corresponds to the coordinates horizontal 0°, vertical 0.86°U. Vertical position* Horizontal position* Luminous intensity candela Designated lines or above h + left of v: - To comply zones Equivalent Equivalent below h - right of v: + 20 per cent 30 per cent from 5° inwards Line 6*** -2.5° 1,890 min All line to 10° outwards 2,160 min Line 8 One or more -1.5° to -3.5° -22° and +22° 880 min 770 min L and R*** points Line 9 One or more -1.5° to -4.5° -35° and +35° 360 min 315 min points L and R*** Zone D -1.5° to -3.5 ° -10° to +10° 14,400 max 15,600 max Whole zone * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.4. of this Regulation. *** See paragraph 6.4.3.2. of this Regulation.
Annex 3changed
lamps of Class B and Class F3 Figure 1 a > 5 mm The device bearing the above approval marking is a fog lamp of Class "B" approved in the Germany (E 1) under number 221, in accordance with this Regulation. The number mentioned close to the symbol "B" indicates that the approval was granted in accordance with the requirements of this Regulation as amended by the 04 series of amendments.1 any other lamp with which it may be reciprocally incorporated. Figure 2a a > 5 mm 1 The 05 series of amendments does not require changes in the approval number (TRANS/WP.29/815, para. 82).
Figure 3changed
Examples of possible markings for grouped, combined or reciprocally incorporated lamps situated on the front of a vehicle E3 30 17120 02 A 00 HCR PL 04 B PL 02 1a Model A 02 A 00 HCR PL 04 B PL 02 1a E3 30 Model B 17120 A HCR B 1a 02 PL PL 02 00 04 E4 30 Model C 17122 02 A E4 30 17122 00 HCRPL 04 B PL 02 1a Model D The vertical and horizontal lines indicate a schematic view of the shape of the light- signalling device. These are not part of the approval mark. The devices shown in Model A and Model B of Figure 3 bear the approval markings for a fog lamp approved in Italy (E 3) under number 17120, in accordance with this Regulation. The devices shown in Model C and Model D of Figure 3 bear the approval markings for a fog lamp approved in the Netherlands (E 4) under number 17122, in accordance with this Regulation. Note: The four examples shown in Figure 3 correspond to a lighting device bearing an approval mark relating to: A front position lamp approved in accordance with the 02 series of amendments to UN Regulation No.7; A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam with a maximum intensity comprised between 86,250 and 101,250 candelas (as indicated by the number 30) approved in accordance with the 00 series of amendments to UN Regulation No. 112 and incorporating a lens of plastic material; A front fog lamp approved in accordance with the 04 series of amendments to this Regulation Regulation1 and incorporating a lens of plastic material; A front direction indicator lamp of category 1a approved in accordance with the 02 series of amendments to UN Regulation No. 6.
Figure 1deleted
The device bearing the above approval marking is a fog lamp of Class "B" approved in the Germany (E 1) under number 221, in accordance with this Regulation. The number mentioned close to the symbol "B" indicates that the approval was granted in accordance with the requirements of this Regulation as amended by the 04 series of amendments. any other lamp with which it may be reciprocally incorporated.
Figure 4changed
The example in Figure 4 corresponds to the marking of a lens of plastic material intended for use in different types of headlamps, namely: Either: A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam with a maximum intensity comprised between 86,250 and 101,250 candelas, approved in Sweden (E 5) in accordance with the requirements of UN Regulation No. 112 as amended by the 00 series of amendments, which is reciprocally incorporated with a front fog lamp approved in accordance with the 04 series of amendments to this Regulation; Regulation;1 Or: A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam, approved in Sweden (E 5) in accordance with the requirements of UN Regulation No. 98 as amended by the 00 series of amendments, which is reciprocally incorporated with the same front fog lamp as above; Or even: Either of the above-mentioned headlamps approved as a single lamp. The main body of the headlamp shall bear only the valid approval number. Examples of such valid markings are shown in Figure 5. Annex 3
Figure 5changed
The device bearing the approval marking in Figure 6 is a lamp approved in Belgium (E 6) under number 17120 and 17122, in accordance with this Regulation and, in accordance with UN Regulation No. 23 (reversing lamps):
Figure 7changed
a > 5 mm The device bearing the approval marking shown in Figure 7 is a fog lamp of Class "F3" approved in Germany (E 1) under number 221, in accordance with this Regulation. The number mentioned close to the symbol "F3" indicates that the approval was granted in accordance with the requirements of this Regulation as amended by the 04 series of amendments. amendments.1 The marking in Figure 7 indicates that the device is a front fog lamp, which can be lit simultaneously with any other lamp with which it may be reciprocally incorporated.
Figure 8achanged
a > 5 mm The device bearing the approval marking shown in Figures 8a and 8b is a fog lamp of Class "F3", having a plastic lens and approved in France (E 2) under number 222, in accordance with this Regulation. The number mentioned close to the symbol "F3" indicates that the approval was granted in accordance with the requirements of this Regulation as amended by the 04 series of amendments. amendments.1 Figures 8a and 8b indicate that the device is a front fog lamp incorporating a lens of plastic material and that it cannot be lit simultaneously with any other lamp with which it may be reciprocally incorporated. Note: The approval number and the additional symbols shall be placed close to the circle and either above or below the letter "E", or to the right or left of that letter. The digits of the approval number shall be on the same side of the letter "E" and face the same direction. The use of Roman numerals as approval numbers should be avoided so as to prevent any confusion with other symbols. Annex 3
Figure 9changed
Examples of possible markings for grouped, combined or reciprocally incorporated lamps situated on the front of a vehicle E3 30 17120 02 A 00 HCR PL 04F3 PL 02 1a Model A 02 A 00 HCR PL 04 F3 PL 02 1a E3 30 04F3 PL 02 1a Model B 17120 A HCR F3 1a 02 PL PL 02 00 04 E4 30 Model C 17122 02 A E30 4 17122 00 HCRPL 04 F3 PL 02 1a Model D The vertical and horizontal lines indicate a schematic view of the shape of the light- signalling device. These are not part of the approval mark. The device bearing the approval marking shown in Models A and B in Figure 9 is a fog lamp approved in Italy (E 3) under number 17120 and comprising: A front position lamp approved in accordance with the 02 series of amendments to UN Regulation No. 7; A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam with a maximum intensity comprised between 86,250 and 101,250 candelas (as indicated by the number 30) approved in accordance with the 00 series of amendments to UN Regulation No. 112 and incorporating a lens of plastic material; A front fog lamp approved in accordance with the 04 series of amendments to this Regulation Regulation1 and incorporating a lens of plastic material; A front direction indicator lamp of category 1a approved in accordance with the 02 series of amendments to UN Regulation No. 6. The device bearing the approval marking in Models C and D in Figure 9 is a device approved in the Netherlands (E 4) under number 17122, in accordance with this Regulation used and shows a slightly different arrangement to that shown in Models A and B. Lighting device used either as front fog lamp or as reversing lamp The device bearing the approval marking shown in Figure 10 is a lamp approved in Sweden (E 5) under number 17120 and 17122, in accordance with UN Regulation No. 19 and, in accordance with UN Regulation No. 23 (reversing lamps):
Figure 11changed
The above example corresponds to the marking of a lens of plastic material to be used in different types of headlamps, namely: Either: A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam with a maximum intensity comprised between 86,250 and 101,250 candelas, approved in Belgium (E 6) in accordance with the requirements of UN Regulation No. 112 (Table B) as amended by the 00 series of amendments, which is reciprocally incorporated with a front fog lamp approved in accordance with the 04 series of amendments to this Regulation; 1 Or: Annex 3 A headlamp with a passing-beam designed for right-hand and left-hand traffic and a driving-beam, approved in Belgium (E6) in accordance with the requirements of UN Regulation No. 98 as amended by the 00 series of amendments, which is reciprocally incorporated with the same front fog lamp as above; Or even: Either of the above-mentioned headlamps approved as a single lamp. The main body of the headlamp shall bear only the valid approval number. Examples of such valid markings are shown in Figure 12. Annex 3
2.1.changed
In the case of front fog lamps of Class "B", the measuring grid is shown in Figure 2. Light distribution of the Class B front fog lamp
2.2.changed
In the case of front fog lamps of Class "F3", the measuring grid is shown in Figure 3. Light distribution of the Class F3 front fog lamp Annex 5
Figure 2deleted
3.5° D
Figure 3deleted
Light distribution of the Class F3 front fog lamp Annex 5
1.1.1.1.changed
In the case where only one lighting function (front fog lamp) is to be approved, the corresponding light source is lit for the prescribed time;1 When the tested front fog lamp includes signalling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing operation mode with an on/ off time ratio of approximately one to one.
1.1.1.2.changed
In the case of more than one lighting function (e.g. a headlamp with one or more driving-beams and/or a front fog lamp): the headlamp shall be subjected to the following cycle until the prescribed time is reached: (a) 15 minutes, front fog lamp lit; (b) 5 minutes, all filaments lit. If the applicant declares that only one lighting function is to be used at a time (e.g. only the passing-beam lit or only the driving-beam(s) lit or only the front fog lamp lit1), the test shall be carried out in accordance with this condition, successively activating the front fog lamp half of the time and one 1 When the tested front fog lamp includes signalling lamps, the latter shall be lit for the duration of the test, except for a daytime running lamp. In the case of a direction indicator lamp, it shall be lit in flashing operation mode with an on/ off time ratio of approximately one to one. of the other lighting functions for half the time specified in paragraph 1.1. above.
1.1.1.3.changed
In the case of front fog lamp with a passing-beam and one or more lighting functions (one of them is a front fog lamp): (a) The front fog lamp shall be subjected to the following cycle until the time specified is reached: (i) 15 minutes, passing-beam light source(s) lit; (ii) 5 minutes, all light source(s) lit. (b) If the applicant declares that the front fog lamp is to be used with only the passing-beam lit or only the front fog lamp 2 lamp2 lit at a time, the test shall be carried out in accordance with this condition, successively activating3 the passing-beam half of the time and the front fog lamp for half of the time specified in paragraph 1.1. above. The driving- beam(s) is (are) subjected to a cycle of 15 minutes off and 5 minutes lit for half of the time and during the operation of the passing-beam; (c) If the applicant declares that the front fog lamp can be used with only the passing-beam or only the driving-beam(s)2 lit or only the front fog lamp2 lit at a time, the test shall be carried out in accordance with this condition, successively activating2 the passing-beam one third of the time, the driving-beam(s) one third of the time and the front fog lamp for one third of the time specified in paragraph 1.1.
1.1.2.changed
The voltage shall be applied to the terminals of the test sample as follows: (a) In case of replaceable filament light source(s) operated directly under vehicle voltage system conditions: The test shall be performed at 6.3 V, 13.2 V or 28.0 V as applicable except if the applicant specifies that the test sample may be used at a different voltage. In this case, the test shall be carried out with the filament light source operated at the highest voltage that can be used; Should two or more lamp filaments be simultaneously lit when headlamp flashing is used, this shall not be considered as being normal use of the filaments simultaneously. When the tested headlamp includes signalling lamps, the latter shall be lit for the duration of the test. In the case of a direction indicator lamp, it shall be lit in flashing mode with an on/off time of approximately one to one. Annex 5 (b) In case of replaceable gas discharge light source(s): the test voltage for the electronic light source control-gear is 13.2 ± 0.1 volts for 12 V vehicle voltage systems, or otherwise specified in the application for approval; (c) In the case of non-replaceable light source operated directly under vehicle voltage system conditions: all measurements on lighting units equipped with non-replaceable light sources (filament light sources and/ or others) shall be made at 6.3 V, 13.2 V or 28.0 V or at other voltages according to the vehicle voltage system as specified by the applicant respectively; (d) In the case of light sources, replaceable or non-replaceable, being operated independently from vehicle supply voltage and fully controlled by the system, or, in the case of light sources supplied by a supply and operating device, the test voltages as specified above shall be applied to the input terminals of that device. The test laboratory may require from the manufacturer the supply and 2 Should two or more lamp filaments be simultaneously lit when headlamp flashing is used, this shall not be considered as being normal use of the filaments simultaneously. 3 When the tested headlamp includes signalling lamps, the latter shall be lit for the duration of the test. In the case of a direction indicator lamp, it shall be lit in flashing mode with an on/off time of approximately one to one. Annex 5 operating device or a special power supply needed to supply the light source(s); (e) LED module(s) shall be measured at 6.75 V, 13.2 V or 28.0 V respectively, if not otherwise specified within this Regulation. LED module(s) operated by an electronic light source control gear, shall be measured as specified by the applicant; (f) Where signalling lamps are grouped, combined or reciprocally incorporated into the test sample and operating at voltages other than the nominal rated voltages of 6 V, 12 V or 24 V respectively, the voltage shall be adjusted as declared by the manufacturer for the correct photometric functioning of that lamp. (g) For a gas-discharge light source, the test voltage for the ballast or for the light source in case the ballast is integrated with the light source is 13.2  0.1 volts for 12 V network system, or otherwise specified in the application for approval.
1.2.1.1.1.changed
For front fog lamps with the outside lens in glass: The mixture of water and a polluting agent to be applied to the front fog lamp shall be composed of: (a) 9 parts by weight of silica sand with a particle size of 0-100 µm; µm, (b) 1 part by weight of vegetal carbon dust (beech wood) produced from beech wood with a particle size of 0-100 µm; µm, (c) 0.2 part by weight of NaCMC,4 NaCMC4, (d) 5 parts by weight of sodium chloride (pure at 99 per cent), and (d) (e) An appropriate quantity of distilled water, water with a conductivity of S < l µS/m.  1 mS/m The mixture must not be more than 14 days old.
1.2.1.1.2.changed
For front fog lamp with the outside lens in plastic material: The mixture of water and polluting agent to be applied to the front fog lamp shall be composed of: (a) 9 parts by weight of silica sand with a particle size of 0-100 µm, µm; (b) 1 part by weight of vegetal carbon dust (beech wood) produced from beech wood with a particle size of 0-100 µm, µm; (c) 0.2 part by weight of NaCMC,4 NaCMC 4; (d) 5 parts by weight of sodium chloride (pure at 99 per cent); (e) 13 parts by weight of distilled water with a conductivity of S < 1 µS/m, and (e) ±1 part by weight mS/m; (f) 2 ± 1 drops of surfactant.5 surfactant5. The mixture must shall not be more than 14 days old. NaCMC represents the sodium salt of carboxymethylcellulose, customarily referred to as CMC. The NaCMC used in the dirt mixture shall have a degree of substitution (DS) of 0.6-0.7 and a viscosity of 200-300 µP for a 2 per cent solution at 20 ºC. The tolerance on quantity is due to the necessity of obtaining a dirt that correctly spreads out on all the plastic lens. Annex 5
2.2.added
Annex 5
2.2.2.changed
However, if this value is more than 2 mrad but not more than 3 mrad (2 mrad < ∆rI ∆r ≤ 3 mrad) a second further sample of a front fog lamp mounted on a test fixture representative of the correct installation on the vehicle shall be tested as described in paragraph 2.1. above This shall be done after the front fog lamp has been being subjected to three consecutive cycles times to the cycle as described below, in order to stabilise the position of the mechanical parts of the front fog lamp that is mounted on a base representative of the correct installation on the vehicle: lamp: (a) Operation of the front fog lamp for one hour. (The hour (the voltage shall be adjusted as specified in paragraph 1.1.2. of this annex). annex); (b) Period of rest for one hour. One hour period with the lamp switched off.
2.2.3.changed
The After these three cycles, the front fog lamp type shall be considered as acceptable if the mean value of the absolute values ∆ rI Δr measured according to paragraph 2.1. above on this further sample meet the first sample and ∆ rII measured on the second sample is not more than 2 mrad. (∆ rI + ∆ rII) / 2 ≤ 2 mrad. requirements in paragraph 2.2.1. above.
2.3.2.changed
The outer face of these three samples shall then be lightly rubbed for one minute with a cotton cloth soaked in a mixture composed of 70 per cent n-heptane and 30 per cent toluene (volume per cent), and shall then be dried in the open air. Annex 6
2.3.3.changed
After the above two tests have been performed successively, the mean value of the variation in transmission: ∆t = (T2 - T3) / T2, Annex 6 measured on the three samples according to the procedure described in Appendix 2 to this annex shall not exceed 0.010 (∆ tm ≤ 010).
2.changed
The following readings shall be taken: Reading With sample With central part of DD Quantity represented T1 no no Incident flux in initial reading T2 yes no Flux transmitted by the new (before test) material in a field of 24 degrees T3 yes no Flux transmitted by the tested (after test) material in a field of 24 degrees T4 yes yes Flux diffused by the new material (before test) T5 yes yes Flux diffused by the tested (after test) material 1 For L2 the use a focal distance of about 80 mm is recommended. Annex 6 - Appendix 3
2.changed
In the first sampling four front fog lamps shall be are selected at random. The first sample of two is marked A, the second sample of two is marked B.
2.1.added
The conformity of mass-produced front fog lamps shall not be contested if the deviation of any specimen of samples A and B (all four lamps) is not more than 20 per cent. In the case, that the deviation of both lamps of sample A is not more than 0 per cent, the measurement can be closed.
2.2.added
The conformity of mass-produced front fog lamps shall be contested if the deviation of at least one specimen of samples A or B is more than 20 per cent. The manufacturer shall be requested to bring his production in line with the requirements (alignment) and a repeated sampling according to paragraph 3. below shall be carried out within two months' time after the notification. The samples A and B shall be retained by the Technical Service until the entire CoP process is finished.
3.changed
In the cases A sample of A3, B2, B3 a repeated sampling, third sample C of two front fog four lamps and fourth sample D of two front fog lamps, is selected at random from stock manufactured after alignment, alignment. The first sample of two is necessary within marked C, the second sample of two month time after the notification. is marked D.
3.1.added
The conformity of mass-produced front fog lamps shall not be contested if the deviation of any specimen of samples C and D (all four lamps) is not more than 20 per cent. In the case, that the deviation of both lamps of sample C is not more than 0 per cent, the measurement can be closed.
3.2.added
The conformity of mass-produced front fog lamps shall be contested if the deviation of at least.
2.1.1.deleted
Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced front fog lamps shall not be contested if the deviation of the measured values of the front fog lamps in the unfavourable directions is:
3.2.1.changed
Following the sampling procedure shown in Figure 1 One specimen of this annex the conformity of mass-produced front fog lamps shall be contested and the manufacturer requested to make his production meet the requirements (alignment) if the deviations of the measured values of the front fog lamps are: Sample samples C or D D2: in the case of C2 one front fog lamp more than 0 per cent but not is more than 20 per cent one front fog lamp but the deviation of all specimen of these samples is not more than 20 30 per cent cent. The manufacturer shall be requested again to bring his production in line with the requirements (alignment). A second repeated sampling according to paragraph 4. below shall be carried out within two months' time after the notification. The samples C and D shall be retained by the Technical Service until the entire COP process is finished.
2.1.1.1.deleted
Sample A A1: one front fog lamp 0 per cent one front fog lamp not more than 20 per cent A2: both front fog lamps more than 0 per cent but not more than 20 per cent Go to sample B
3.2.2.added
One specimen of samples C and D is more than 30 per cent. In this case the approval shall be withdrawn and paragraph 5 below shall be applied.
2.1.1.2.deleted
B1: both front fog lamps 0 per cent
4.changed
With respect to the verification A sample of the change in vertical positions four lamps is selected at random from stock manufactured after alignment. The first sample of the cut- off line under the influence of heat, the following procedure shall be applied: One of the front fog lamps of sample A after sampling procedure in Figure 1 of this annex shall be tested according to the procedure described in paragraph 2.1. of Annex 4 after being subjected three consecutive times to the cycle described in paragraph 2.2.2. of Annex 4. The front fog lamp shall be considered as acceptable if ∆r does not exceed 3.0 mrad. If this value exceeds 3.0 mrad but two is not more than 4.0 mrad, marked E, the second front fog lamp sample of sample A shall be subjected to the test after which the mean of the absolute values recorded in both samples shall not exceed 3.0 mrad. However, if this value of 3.0 mrad on sample A two is not complied with, the two front fog lamps of sample B shall be subjected to the same procedure and the value of ∆r for each of them shall not exceed 3.0 mrad. Annex 8 marked F.
4.1.added
The conformity of mass-produced front fog lamps shall not be contested if the deviation of any specimen of samples E and F (all four lamps) is not more than 20 per cent. In the case, that the deviation of both lamps of sample E is not more than 0 per cent, the measurement can be closed.
2.2.1.deleted
Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced front fog lamps shall be contested and the manufacturer requested to make his production meet the requirements (alignment) if the deviations of the measured values of the front fog lamps are:
4.2.added
The conformity of mass-produced front fog lamps shall be contested if the deviation of at least one specimen of samples E or F is more than 20 per cent. In this case the approval shall be withdrawn and paragraph 5 below shall be applied.
2.2.1.1.deleted
Sample A A3: one front fog lamp not more than 20 per cent one front fog lamp more than 20 per cent but not more than 30 per cent
5.added
Approval shall be withdrawn according to paragraph 11. of this Regulation.
2.2.1.2.deleted
B2: in the case of A2 one front fog lamp more than 0 per cent but not more than 20 per cent one front fog lamp not more than 20 per cent B3: in the case of A2 one front fog lamp 0 per cent one front fog lamp more than 20 per cent but not more than 30 per cent
6.added
With respect to the verification of the change in vertical positions of the cut- off line under the influence of heat, the following procedure shall be applied: One of the front fog lamps of sample A after sampling procedure in paragraph 2. of this Annex shall be tested according to the procedure described in paragraph 2.1. of Annex 4 after being subjected three consecutive times to the cycle described in paragraph 2.2.2. of Annex 4. The front fog lamp shall be considered as acceptable if ∆r does not exceed 3.0 mrad. Annex 8 If this value exceeds 3.0 mrad but is not more than 4.0 mrad, the second front fog lamp of sample A shall be subjected to the test after which the mean of the absolute values recorded in both samples shall not exceed 3.0 mrad. However, if this value of 3.0 mrad on sample A is not complied with, the two front fog lamps of sample B shall be subjected to the same procedure and the value of ∆r for each of them shall not exceed 3.0 mrad.
2.3.deleted
Conformity shall be contested and paragraph 11. of this Regulation applied if, following the sampling procedure in Figure 1 of this annex, the deviations of the measured values of the front fog lamps are:
2.3.1.deleted
Sample A A4: one front fog lamp not more than 20 per cent one front fog lamp more than 30 per cent A5: both front fog lamps more than 20 per cent Annex 8
2.3.2.deleted
B4: in the case of A2 one front fog lamp more than 0 per cent but not more than 20 per cent one front fog lamp more than 20 per cent B5: in the case of A2 both front fog lamps more than 20 per cent B6: in the case of A2 one front fog lamp 0 per cent one front fog lamp more than 30 per cent
3.1.1.deleted
Following the sampling procedure shown in Figure 1 of this annex the conformity of mass-produced front fog lamps shall not be contested if the deviations of the measured values of the front fog lamps are:
3.2.changed
After horizontal adjustment of the front fog beam according to paragraph 3.1. above, the vertical adjustment shall be performed in such a way that the cut-off line is moved upwards from the lower position until it is situated on the v-v line at 1° below the h-h line. If the horizontal part is not straight but slightly curved or inclined, the cut-off line shall not exceed the vertical range formed by two horizontal lines which are situated between 3° left and right of the v-v line at 0.2° above and below the nominal position of the cut-off (see Figure 1). Annex 9
3.1.1.1.deleted
C1: one front fog lamp 0 per cent one front fog lamp not more than 20 per cent C2: both front fog lamps more than 0 per cent but not more than 20 per cent Go to sample D
3.2.1.changed
When the vertical positions of three attempts to adjust the cut-off differ by more than 0.2°, the horizontal part of the cut-off line is assumed not to provide sufficient linearity or sharpness for performing visual adjustment. In this case the quality of cut-off shall be tested instrumentally for compliance with requirements as follows. Annex 9
3.1.1.2.deleted
D1: in the case of C2 both front fog lamps 0 per cent
3.3.deleted
Conformity shall be contested and paragraph 11. applied if, following the sampling procedure in Figure 1 of this annex, the deviations of the measured values of the front fog lamps are:
3.3.1.deleted
C3: one front fog lamp not more than 20 per cent one front fog lamp more than 20 per cent C4: both front fog lamps more than 20 per cent
3.3.2.deleted
D3: in the case of C2 one front fog lamp 0 or more than 0 per cent one front fog lamp more than 20 per cent
Figure 1deleted
direction in relation to the limit values
1.1.changed
Each LED module or light-generator sample submitted shall conform to the relevant specifications of this Regulation when tested with the electronic light source control-gear(s) supplied, if any.
1.2.changed
LED modules or light-generators shall be so designed as to be, and to remain in good working order when in normal use. They shall moreover exhibit no fault in design or manufacture.
1.3.changed
LED modules or light-generators shall be tamperproof.
2.2.changed
In case of LED modules or light-generator(s): modules:
Annex 12deleted
generators
3.1.2.changed
The type of light sources shall be as defined in UN Regulation No. 48 paragraph 2.7.1., in particular with regard to the element of visible radiation. Other types of light sources are not permitted.
3.1.3.2.changed
If not specified differently in this annex, LED modules or light-generators shall be tested inside the front fog lamp as submitted by the manufacturer.
3.2.1.changed
LED modules or light-generators shall be aged.
3.2.2.changed
The tests below shall be carried out after ageing with the LED module(s) or light-generator(s) supplied by the submitted electronic light source control- gear control-gear at test voltage.
3.2.4.changed
Filament lamps shall first be aged at their test voltage for approximately one hour. For dual-filament lamps, each filament shall be aged separately. Annex 12
4.changed
Filament lamps approved according to UN Regulation No. 37, gas-discharge light sources approved according to UN Regulation No. 99 and LED modules are exempted from the tests indicated in paragraphs 4.3.1. and 4.3.2. below.
2.2.3.deleted
The light source in the light generator shall be equipped with suitable fixation elements.
2.2.4.deleted
The fixation elements shall be strong and firmly secured to the light source(s) and the light generator.
3.1.3.deleted
LED module or light-generator operating conditions:
4.4.2.changed
The light source shall be started and be operated with the electronic light source control-gear at test voltage for a period of 15 minutes. The supply voltage to the electronic light source control-gear shall then be switched off for a period of 10 seconds, and be switched on again. The light source shall restart directly after being switched-off for a period of 10 seconds. After one second the light source shall emit at least 80 per cent of its objective luminous flux. Annex 12
4.5.1.changed
In addition to measurements as described in paragraph 7. of this Regulation, the minimum red content of the light of a LED module or light-generator shall be such that: 780 nm  E e ( (  ) V( V (  ) d  610 =610 nm k red = 780 nm  0.05  E e ( (  ) V( V (  ) d  380 =380 nm Where: Ee () (unit: W) is the spectral distribution of the irradiance; V() (unit: 1) is the spectral luminous efficiency;  (unit: nm) is the wavelength. This value shall be calculated using intervals of one nanometre.
3.1.5.deleted
In case of light-generators:
4.6.changed
The UV-radiation of the a low-UV-type LED module or light-generator shall be such that: 400 nm  E e () S() ( ) S( ) d  250 =250 nm k UV = 780 nm  105 10−5 W / lm km  E e () V() ( ) V( ) d  380 =380 nm Where: S()(unit: 1) is the spectral weighting function; km = 683 lm/W is the maximum value of the luminous efficacy of radiation; (For definitions of the other symbols see paragraph 4.5.1. above.) This value shall be calculated using intervals of one nanometre. The UV- radiation shall be weighted according to the values as indicated in the UV table below. UV Table  S()  S()  S() 250 0.430 305 0.060 355 0.000 16 255 0.520 310 0.015 360 0.000 13 260 0.650 315 0.003 365 0.000 11 265 0.810 320 0.001 370 0.000 09 270 1.000 325 0.000 50 375 0.000 077 275 0.960 330 0.000 41 380 0.000 064 280 0.880 335 0.000 34 385 0.000 530 053 285 0.770 340 0.000 28 390 0.000 044 290 0.640 345 0.000 24 395 0.000 036 295 0.540 350 0.000 20 400 0.000 030 300 0.300 Annex 12 UV Table Values according to "IRPA/INIRC Guidelines on limits of exposure to ultraviolet radiation". Wavelengths (in nanometres) chosen are representative; other values should be interpolated.
3.1.5.1.deleted
The power supply used for the starting and run-up tests shall be sufficient to secure the quick rise of the high current pulse.
3.1.5.2.deleted
The burning position shall be as indicated by the applicant. Ageing and testing positions shall be identical. If the lamp is accidentally operated in the wrong direction, it shall be re-aged before measurements begin. During ageing and measurements no electrically conducting objects shall be allowed within a space as indicated by the applicant. Moreover stray magnetic fields shall be avoided.
4.7.2.changed
The colour of the light emitted, measured after 1 minute and measured after 30 minutes photometric stability has been obtained, as described in paragraph 4.7.1.3. of operation, this annex, shall be within the required colour boundaries in both instances.