Compare versions of UN R27
Advance-warning triangles
2.9.changed
"Fluorescent retro-reflecting material" means a material with retro-reflecting properties which, when excited by daylight, exhibits the phenomenon of photo-luminescence photo- luminescence ceasing rather shortly after excitation.
5.2.changed
The approval number shall be assigned to each type approved. Its first two digits (at present 04 corresponding to the 04 series of amendments) 1 shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party shall not assign the same number to another type of advance warning triangle covered by this Regulation.
5.3.changed
Notice of approval or of refusal of approval of a type of advance warning triangle pursuant to this Regulation shall be communicated to the countries Parties to the Agreement which apply this Regulation by means of a form conforming to the model in Annex 1 to this Regulation accompanied by 1 The 05 series of amendments does not require changes in the approval number (TRANS/WP.29/815, para. 82). dimensional drawings (supplied by the applicant for approval) in a format not exceeding A4 (210 x 297 mm), or folded to that format, and on an appropriate scale.
5.4.1.1.changed
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval;1 approval;2
6.2.changed
Advance warning triangles shall be so made that in normal use (on the road and when carried in the vehicle) they retain the prescribed characteristics and their satisfactory functioning continues to be ensured. The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev. 3, Annex 3 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
6.7.changed
The advance warning triangle shall be accompanied by its protective cover, if any, against external agents, especially during carriage; it may however be supplied without protective cover where the necessary protection is provided by other means. These means shall be stated in the description mentioned in 2 The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.6) paragraph 3.2. above and in the communication form under paragraph 5.3. of this Regulation.
7.1.1.6.changed
The side of the open centre of the triangle shall have a minimum length of 70 mm (Fig. (Figure 1).
7.3.1.1.changed
The values of the CIL of retro-reflecting optical units or the fluorescent retro- reflecting material shall be not less than those given in the table below, expressed in millicandelas per lux, for the angles of divergence and the illumination angle shown: Illumination angles β Vertical V (β1) 0° ±20° 0° 0° Horizontal H (β2) 0° or ±5° 0° ±30° ±40° Angles of divergence 20' 8,000 4,000 1,700 600 Angles of divergence 1°30' 600 200 100 50 1°30'
7.3.1.3.changed
9.2.changed
Notice of confirmation of approval, specifying the modifications, or of refusal of approval shall be communicated by the procedure specified in paragraph 5.3. above to the Parties to the Agreement which apply this Regulation.
5.3.added
above to the Parties to the Agreement which apply this Regulation.
10.changed
The conformity of production procedures shall comply with those set out in the Agreement, Appendix 2 (E/ECE/324-E/ECE/TRANS/505/Rev.2), Schedule 1 (E/ECE/TRANS/505/Rev.3), with the following requirements:
10.1.changed
Advance warning triangles approved under this Regulation shall be so manufactured as to conform to the type approved under this Regulation. The compliance with the requirements set forth in paragraphs 6., 7. and 8. above shall be verified as follows:
10.1.2.changed
The minimum requirements for conformity Conformity of production Production (CoP) control procedures set forth in Annex 7 to this Regulation shall be complied with.
14.1.changed
14.2.changed
14.3.changed
14.4.deleted
14.3.added
Contracting Parties applying this Regulation shall continue to allow fitting or
use on a vehicle in use of a device approved to this Regulation as amended by
any previous series of amendments, provided that the device is intended for
replacement.
3 The 05 series of amendments does not require changes in the approval number (TRANS/WP.29/815,
para. 82).
Annex 1
Annex 1changed
(Maximum format: A4 (210 x 297 mm)) issued by: Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of advance warning triangle pursuant to UN Regulation No. 27.
11.deleted
16.changed
The following documents, bearing the approval number shown above, are annexed to this communication: 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply.
Annex 2changed
27R04216 27R04216 a 8 mm An advance warning triangle bearing one of the approval marks shown above has been approved in the Netherlands (E 4) under approval number 04216. The first two digits of the approval number indicate that the approval was granted according to the requirements of this Regulation as amended by the 04 series of amendments. amendments.1 Note: The drawings show several possible embodiments and are given by way of example. The Type Approval Authorities shall avoid using Roman numerals for the approval, in order to prevent any confusion with other symbols. 1 The 05 series of amendments does not require changes in the approval number (TRANS/WP.29/815, para. 82). Annex 3
2.1.changed
A known volume V of sand is spread evenly on the surface of the carriageway in the form of a circle. The ratio of the volume used to the area S covered is defined as "mean sand depth" HS and is expressed in mm: V HS = S
2.2.changed
The test is carried out by means of round-grain, dry sand and having a grain size between 0.160 mm and 0.315 mm. The volume amounts to 25 ml ± 0.15 ml. The sand is spread out over the surface where the test is carried out by means of a flat, circular disc with a diameter of 65 mm, one side of which is covered with a sheet of rubber having a thickness of 1.5 mm to 2.5 mm and the other being provided with an appropriate handle. If the diameter of the circular area covered with sand is D mm, the mean sand depth will be calculated in accordance with the formula: 4 25 HS = 103 mm D2
1.7.2.changed
Test of the luminance factor according to paragraph 3. below; Annex 5
2.1.1.changed
The colour of the retro- reflecting devices to be tested when illuminated by the CIE standard illuminant A with an angle of divergence of 1/3° and an illumination angle V = H = 0°, or, if this produces a colourless surface reflection, an angle V = ±5°, H = 0° shall be applied. Annex 5
2.2.2.changed
For testing the colour of the fluorescent material, the material shall be illuminated by the CIE Standard Illuminant D65 (ISO 11664-2:2007(E)/CIE S 014-2/E:2006) and measured with a spectrophotometer in accordance with the provisions of publication CIE 15:2004, Recommendations on Colorimetry - second edition, either illuminated polychromatically or with a monochromator providing stepwise the CIE Standard Illuminant D 65 (ISO 11664-2:2007(E)/CIE 11664- 2:2007(E)/CIE S 014-2/E:2006). In the latter case, the stepwise resolution λ shall be not larger than 10 nm. Alternatively similar "illuminants" are allowed, if verified that the colorimetric measuring procedure is of the same sufficient accuracy, meaning that the quality of the simulation of D65 shall be assessed by the method described in ISO 23603:2005(E)/CIE S 012/E:2004. The spectral distribution of the illuminant shall be in category BC (CIELAB) or better. The illumination shall be carried out circumferential at an angle 45º to the normal and viewed along the normal (annular geometry 45/0) (circumferential/normal geometry), as described in Annex 10 to this Regulation.
3.1.changed
For the determination of the luminance factor the sample shall be tested for advance warning triangle of (a) Type 1 with the same method as described in paragraph 2.2.1 of this annex and (b) Type 2 with the same method as described in paragraph 2.2.2. of this annex. 3.1.1 By putting the luminance L of the sample into relation to the luminance Lo L o of a perfect diffuser whose luminance factor o is known under identical conditions of illumination and observation; the luminance factor of of the sample then results from the formula: L = o Lo
3.1.2.changed
When the colour of the fluorescent material has been colorimetrically determined in compliance with paragraph 2.2. above, from the ratio of the tristimulus value Y the sample and the tristimulus value of the perfect diffuser Yo; in this case it is: Y = Y0
4.1.changed
H = V = for for the advance warning triangle in its position of use is parallel to the base plane and vertical to the lower side of the triangle, which in turn is parallel to the said base plane.
5.1.2.changed
The individual supports to the ground shall be placed one after another in the square hole of of the test apparatus. During the test of each support, it shall be required to find a position of the test apparatus in relation to the advance warning triangle and its supporting device, which is favourable for the triangle and which ensures that:
6.1.changed
When the advance warning triangle has been set up as required by the manufacturer and its bases are firmly held, a force of 2 N shall be applied to the apex of the triangle parallel to the supporting surface and normal to the lower side of the triangle. Annex 5
7.3.changed
After the heat-resistance test and subsequent storage for 12 consecutive hours at a temperature of 25 °C ± 5 °C, the advance warning triangle, in its protective cover, is to be kept for another 12 hours in a dry atmosphere at a temperature of -40 °C ± 2 °C. Annex 5
10.1.changed
The advance warning triangle shall be set up in a wind tunnel, on a base measuring about 1.50 m by 1.20 m with a surface formed of abrasive material of the type P36 corresponding to the FEPA 1 FEPA1 specification 43-1-2006. This surface shall be characterised by its geometric roughness, HS = 0.5 mm ± 0.05 mm, which shall be defined and determined by the so-called "sandy beach" method according to Annex 4 of this Regulation. FEPA: Federation of European Producers of Abrasives, 20 Avenue Reille, 75014 Paris, France. To avoid a laminar boundary layer of the incident flow over the surface of the base, this base shall have a splitter plate and shall be set up in such a way, that the flow is completely around the plate.
10.5.changed
The retro-reflecting triangular part of the device shall not rotate through more than 10° round a horizontal axis or a vertical axis from its initial position. The 1 FEPA: Federation of European Producers of Abrasives, 20 Avenue Reille, 75014 Paris, France. rotation around the horizontal axis or the vertical axis shall be determined by the aid of a virtual plane at the initial position of the retro- reflecting retro-reflecting triangular part of the device, which is orthogonal to the base and orthogonal to the air stream.
11.1.3.changed
If the visual inspection does not reveal the presence of water, or in case of doubt the value of the CIL shall again be measured under the same conditions as specified in paragraph 1.2. above, after the retro-reflecting device has been gently shaken to remove excess water from the outside. The CIL shall not have diminished by more than 40 per cent of the values recorded before the test. Annex 5
11.2.changed
Test of resistance of the accessible reverse side of the mirror-backed retro- reflecting device The reverse side of the retro-reflecting device shall be brushed with a hard nylon brush and then covered or thoroughly wetted for one minute with a mixture of 70 per cent n-heptane and 30 per cent toluene. The fuel shall then be removed and the device allowed to dry. As soon as evaporation is completed, the reverse side shall be brushed with the same brush as before. The value of the CIL shall then be measured under the same conditions as specified in paragraph 1.2. above, after the whole surface of the mirror- coated mirror-coated reverse side has been covered with Indian ink. The CIL shall not have diminished by more than 40 per cent of the values recorded before the test. This test is not applicable for fluorescent retro-reflecting material.
12.2.changed
After this test, the colour co-ordinates of the fluorescent material shall comply with colour specification in paragraph 7.2.2.2. of this Regulation. The luminance factor (see paragraph 3. above) shall comply with paragraph 7.2.2.3. of this Regulation and shall not have increased by more than 5 per cent compared with the value ascertained according to paragraph 1.7.2. above
7.2.2.3.deleted
12.3.changed
The sample shall not exhibit any visible damage such as cracks, scaling or peeling of the fluorescent or of the fluorescent retro-reflecting material. Annex 5
2.deleted
2.2.changed
The measuring distance shall be chosen in such an order that at least the limits for the angles , and given and given in Figure 4 are respected, but not lower than 10 m or its optical equivalent.
2.6.changed
The amount and distribution of the regular reflection from the surface of the retro-reflector depends on the flatness and the gloss of the surface. In general, regular reflection is best avoided when the reference axis is placed so that the regular reflection is directed on the opposite side of the source from the photometer head (for example with 1 = -5°). Annex 6
3.1.1.changed
Since very low light levels are to be measured special precautions are needed to minimize errors due to stray light. The background to the sample and the framework of the sample holder should be matt black and the field of view of Annex 6 the photometer head and the spread of light from both the sample and the source should each be restricted as much as possible.
Figure 4changed
For the purpose of this Regulation, the following limits are set up: 10' 10' 80' 10' 10' 80' Annex 7
2.changed
In the first sampling four advance warning advance-warning triangles are selected at random. The first sample of two is marked A, the second sample of two is marked B.
2.1.added
The conformity of mass-produced advance-warning triangles shall not be
contested if the deviation of any specimen of samples A and B (all four
advance-warning triangles) is not more than 20 per cent.
In the case that the deviation of both advance-warning triangles of sample A is
not more than 0 per cent, the measurement can be closed.
2.2.added
The conformity of mass-produced advance-warning triangles shall be
contested if the deviation of at least one specimen of samples A or B is more
than 20 per cent.
The manufacturer shall be requested to bring his production in line with the
requirements (alignment) and a repeated sampling according to paragraph 3.
below shall be carried out within two months' time after the notification. The
samples A and B shall be retained by the Technical Service until the entire CoP
process is finished.
2.1.1.deleted
3.changed
2.1.1.1.deleted
3.1.added
The conformity of mass-produced advance-warning triangles shall not be
contested if the deviation of any specimen of samples C and D (all four
advance-warning triangles) is not more than 20 per cent.
In the case that the deviation of both advance-warning triangles of sample C is
not more than 0 per cent, the measurement can be closed.
2.1.1.2.deleted
3.2.added
The conformity of mass-produced advance-warning triangles shall be
contested if the deviation of at least:
3.2.1.changed
2.2.1.deleted
3.2.2.added
One specimen of samples C and D is more than 30 per cent.
In this case the approval shall be withdrawn and paragraph 5. below shall be
applied.
2.2.1.1.deleted
4.changed
2.2.1.2.deleted
4.1.added
The conformity of mass-produced advance-warning triangles shall not be
contested if the deviation of any specimen of samples E and F (all four
advance-warning triangles) is not more than 20 per cent.
In the case that the deviation of both advance-warning triangles of sample E is
not more than 0 per cent, the measurement can be closed.
2.3.deleted
4.2.added
The conformity of mass-produced advance-warning triangles shall be
contested if the deviation of at least one specimen of samples E or F is more
than 20 per cent.
In this case the approval shall be withdrawn and paragraph 5. below shall be
applied.
2.3.1.deleted
5.added
Approval shall be withdrawn according to paragraph 9. of this Regulation.
2.3.2.deleted
6.added
With respect to the verification of the normal use the following procedures
shall be applied:
One additional advance-warning triangle shall be tested according to the
procedures described in paragraph 1.5.3. to 1.8.3. of Annex 5.
The advance-warning triangles shall be considered as acceptable if the tests
have been passed.
However, if the test on this sample is not complied with, the two other
additional advance-warning triangles shall be subjected to the same procedure
and both shall pass the test.
Annex 9
3.1.1.deleted
3.1.1.1.deleted
3.1.1.2.deleted
Table 1changed
Reference Dye (Colour Index designation) 1 5 Cl Acid Blue 47 7 Cl Solubilised Vat Blue 5 The 1The Colour Index (third edition) is published by The Society of Dyers and Colourists, P.O. Box 244, Perkin House, 82 Grattan Road, Bradford BD1 2JB, UK, and by The American Association of Textile Chemists and Colorists, P.O. Box 12215, Research Triangle Park, NC 27709-2215, USA.
3.2.1.1.deleted
3.3.deleted
3.3.1.deleted
5.1.changed
The exposure conditions shall comply with the specifications in the Table 2 below. Annex 9
3.3.2.deleted
Table 2changed
Exposure parameters Air–cooled lamp Water–cooled lamp Light/dark/water spray cycle Continuous light without Continuous light without water water spray spray Black standard temperature (47 ± 3) °C using a black (47 ± 3) °C using a black during light only periods standard thermometer standard thermometer Relative humidity Approximately 40 % Approximately 40 % Filters Window glass filters Window glass filters Specifications see paragraph 5.2. Specifications see paragraph 5.2. below below Irradiance (W/m²) controlled at: Over 300 nm to 400 nm range 42 ± 2 42 ± 2 Over 300 nm to 800 nm range 550 630 Note 1: Water used for the specimen spray should contain no more than 1 ppm silica. Higher levels of silica can produce spotting on samples and variability in results. Water of the required purity can be obtained by distillation or by a combination of deionization and reverse osmosis. Note 2: While irradiance levels should be set at the above levels, variations in filter ages and transmissivity, and in calibration variations, will generally mean that irradiance error will be in the order of ±10 per cent. 5.2 Light source The light source shall consist of a xenon arc lamp of correlated colour temperature 5,500 K to 6,500 K, the size of which will depend on the type of apparatus used. The xenon-arc lamp shall use filters that provide a reasonable simulation of solar radiation filtered by typical window glass. Table 3 gives the relative spectral irradiance requirements for the filtered xenon-arc. It is the responsibility of the supplier of the exposure device to provide necessary certification that the filters that they supply for use in the exposure tests described in this standard meets the requirements of Table 3. Annex 9
Table 3changed
Relative spectral irradiance requirements for window glass filters a, b, c, d, e used for the Xenon-arc devices used in this standard. Spectral bandpass Minimum CIE No.85, Table 4 plus window Maximum Wavelength λ in nm %c % c glass % d, e %c l < 300 0.29 300 ≤ λ ≤ 320 0.1 ≤1 2.8 320 < λ ≤ 360 23.8 33.1 35.5 360 < λ ≤400 62.4 66.0 76.2 a Data in Table 3 is the irradiance in the given bandpass expressed as a percentage of the total irradiance from 290 nm to 400 nm. To determine whether a specific filter or set of filters for a Xenon-arc meets the requirements of Table 3, the spectral irradiance from 250 nm to 400 nm shall be measured. The total irradiance in each wavelength bandpass is then summed and divided by the total irradiance from 290 nm to 400 nm. b The minimum and maximum data in Table 3 are based on more than 30 spectral irradiance measurements for water and air cooled Xenon-arcs with window glass filters of various lots and ages. Spectral irradiance data is for filters and Xenon-burners within the ageing recommendations of the device manufacturer. As more spectral irradiance data become available, minor changes in the limits are possible. The minimum and maximum data are at least the three sigma limits from the mean for all measurements. c The minimum and maximum columns will not necessarily sum to 100 per cent because they represent the minimum and maximum for the data used. For any individual spectral irradiance, the calculated percentage for the bandpasses in Table 3 will sum to 100 per cent. For any individual Xenon-arc lamp with window glass filters, the calculated percentage in each bandpass shall fall within the minimum and maximum limits of Table 2. Test results can be expected to differ between exposures using Xenon-arc devices in which the spectral irradiance differ by as much as that allowed by the tolerances. Contact the manufacturer of the Xenon-arc devices for specific spectral irradiance data for the Xenon-arc and filters used. d The data from Table 4 in CIE No. 85 [1] plus window glass was determined by multiplying the CIE No. 85, Table 4 data by the spectral transmittance of 3 mm thick window glass (see ISO 11341 [2]). These data are target values for Xenon-arc with window glass filters. e For the CIE 85 Table 4 plus window glass, the UV irradiance from 300 nm to 400 nm is typically about 9 per cent and the visible irradiance (400 nm to 800 nm) is typically about 91 per cent when expressed as a percentage of the total irradiance from 300 nm to 800 nm. The percentages of UV and visible irradiances on samples exposed in Xenon-arc devices may vary due to the number and reflectance properties of specimens being exposed.
Figure 1deleted
Table 4changed
Blue wool reference 420 nm 300 nm–400 nm No. kj/m² kj/m² 5 L6 340 13824 7 L8 1360 55296 For colour change of step 4 on the grey scale Annex 9
6.7.changed
Unexposed samples of original fabric identical to those being tested are required as references for comparison with the specimens during weathering. Annex 9 – Appendix 1
Table 1changed
Fastness grade CIELab difference Tolerance 5 0 0.2 (4-5) 0.8 ±0.2 4 1.7 ±0.3 (3-4) 2.5 ± 0.35 3 3,4 ±0.4 (2-3) 4.8 ±0.5 2 6.8 ±0.6 (1-2) 9.6 ±0.7 1 13.6 ±1.0 Annex 9 – Appendix 1 Note 1: Bracketed values apply only to the 9-step scale. Note 2: Use of the scale: Place a piece of the original blue reference and the exposed specimen of it side by side in the same plane and oriented in the same direction. Place the grey scale nearby in the same plane. The surrounding field should be neutral grey colour approximately midway between that illustrating grade 1 and that illustrating grade 2 of the grey scale for assessing change in colour (this is approximately Munsell N5). Illuminate the surfaces with north sky light in the Northern hemisphere, south sky light in the Southern hemisphere, or an equivalent source with an illumination of 600 lx or more. The light should be incident upon the surfaces at approximately 45°, and the direction of viewing approximately perpendicular to the plane of the surfaces. Compare the visual difference between original and exposed blue standard with the differences represented by the grey scale. If the 5-step scale is used, the fairness rating of the specimen is that number of the grey scale which has a perceived colour difference equal in magnitude to the perceived colour difference between the original and the treated specimens; if the latter is judged to be nearer the imaginary contrast lying midway between two adjacent pairs than it is to either, the specimen is given an intermediate assessment, for example 4-5 or 2-3. A rating of 5 is given only when there is no perceived difference between the tested specimen and the original material. If the 9-step scale is used, the fastness rating of the specimen is that number of the grey scale which has a perceived colour difference nearest in magnitude to the perceived colour difference between the original and the tested specimens. A rating of 5 is given only when there is no perceived difference between the tested specimen and the original material. Annex 10
Annex 10changed
of the colour and the luminance factor of fluorescent retro- reflective materials Micro-prismatic materials show the phenomenon of "flares" or "sparkles" (Note 1), which might influence the measured results unless special precautions are taken. A reference method, using the wider apertures of the CIE 45°a:0° (or 0°:45°a) geometry is introduced in paragraph 12. of Annex 5 to this Regulation. Ideally, the measurements shall be made using the CIE 45°a:0° (or 0°:45°a), called the forty- five annular / normal geometry (or the normal/ forty-five annular geometry) defined in CIE 15 (see paragraph 12. of Annex 5.) The measurement area shall be minimum 4.0 cm². For this geometry CIE 15 recommends that: (a) The sampling aperture be irradiated uniformly from all directions between two circular cones with their axes normal to the sampling aperture and apices at the centre of the sampling aperture, the smaller of the cones having a half angle of 40° and the larger of 50° ; (b) The receiver uniformly collects and evaluates all radiation reflected within a cone with its axis on the normal to the sampling aperture, apex at the centre of the sampling aperture, and a half angle of 5°. The annular geometry can be approximated by the use of a number of light sources in a ring or a number of fibre bundles illuminated by a single source and terminated in a ring to obtain the CIE 45°c:0° (circumferential / normal geometry) (Note 2, Note 3). An alternative manner of approximation is to use a single light source, but rotate the sample during measurement with a rotational speed that ensures that a number of revolutions takes place during the exposure time interval for a measurement so that all wavelengths are given equal weight (Note 2, Note 3). In addition, the apertures of the light source and the receiver shall have sufficient dimensions in proportion to distances to ensure a reasonable compliance with the above- mentioned above-mentioned recommendations. Note 1: "Flares" or "sparkles" are caused by characteristic paths of rays that enter and leave the sheeting surface at different angles. A characteristic path will dominate by raising the luminance factor value significantly and possibly distorting the chromaticity co-ordinates if it is included within narrow beams of illumination and measurement. However, the average contribution to the daylight reflection is normally small. Note 2: In practice the recommendations can be approximated only. The important issue is that the annular principle is applied and that illumination and collection occur in directions forming fairly large solid angles, as this will reduce the influence of the above-mentioned "sparkles" of micro-prismatic materials and of other variations with the precise geometry shown by some of these materials. Note 3: In spite of such precautions, the practical difficulties of establishing the annular geometry in accordance with the recommendations introduce uncertainty of measurement.