1.Scope
This Regulation shall apply to motor vehicles of categories M 1, M2, N1 and N2 with a reference mass exceeding 2,610 kg and to all motor vehicles of categories M3 and N31. At the request of the manufacturer, the type approval of a completed vehicle given under this Regulation shall be extended to its incomplete vehicle with a reference mass below 2,610 kg. Type approvals shall be extended if the manufacturer can demonstrate that all bodywork combinations expected to be built onto the incomplete vehicle increase the reference mass of the vehicle to above 2,610 kg. At the request of the manufacturer, the type approval of a vehicle granted under this Regulation shall be extended to its variants and versions with a reference mass above 2,380 kg provided that it also meets the requirements relating to the measurement of greenhouse gas emissions and fuel consumption in accordance with paragraph 4.2. of this Regulation.
Equivalent approvals
The following do not need to be approved according to this Regulation: engines mounted in vehicles of up to 2,840 kg reference mass to which an approval to Regulation No. 83 has been granted as an extension.
2.Definitions
For the purposes of this Regulation the following definitions shall apply:
"Ageing cycle" means the vehicle or engine operation (speed, load, power) to be executed during the service accumulation period;
"Approval of an engine (engine family)" means the approval of an engine type (engine family) with regard to the level of the emission of gaseous and particulate pollutants, smoke and the on-board diagnostic (OBD) system;
"Approval of a vehicle" means the approval of vehicle type with regard to the level of the emission of gaseous and particulate pollutants and smoke by its engine as well as the on-board diagnostic (OBD) system and the engine installation on the vehicle;
"Auxiliary Emission Strategy" (AES) means an emission strategy that becomes active and replaces or modifies a base emission strategy for a specific purpose and in response to a specific set of ambient and/or operating conditions and only remains operational as long as those conditions exist;
"Base Emission Strategy" (BES) means an emission strategy that is active throughout the speed and load operating range of the engine unless an AES is activated;
As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.2, para. 2. - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html.
"Continuous regeneration" means the regeneration process of an exhaust after-treatment system that occurs either permanently or at least once per World Harmonised Transient Driving Cycle (WHTC) hot start test;
"Crankcase" means the spaces in, or external to, an engine which are connected to the oil sump by internal or external ducts through which gases and vapours can be emitted;
"Critical emission-related components" means the following components which are designed primarily for emission control: any exhaust after- treatment system, the ECU and its associated sensors and actuators, and the exhaust gas recirculation (EGR) system including all related filters, coolers, control valves and tubing;
"Critical emission-related maintenance" means the maintenance to be performed on critical emission-related components;
"Defeat strategy" means an emission strategy that does not meet the performance requirements for a base and/or auxiliary emission strategy as specified in this annex;
"deNOx system" means an exhaust after-treatment system designed to reduce emissions of oxides of nitrogen (NOx) (e.g. passive and active lean NOx catalysts, NOx adsorbers and selective catalytic reduction (SCR) systems);
"Diagnostic trouble code" (DTC) means a numeric or alphanumeric identifier which identifies or labels a malfunction;
"Driving cycle" means a sequence consisting of an engine start, an operating period (of the vehicle), an engine shut-off, and the time until the next engine start;
"Element of design" means in respect of a vehicle or engine:
(a) Any element of the engine system;
(b) Any control system, including: computer software; electronic control systems; and computer logic;
(c) Any control system calibration; or
(d) The results of any interaction of systems;
"Emission control monitoring system" means the system that ensures correct operation of the NOx control measures implemented in the engine system according to the requirements of paragraph 5.5; "Emission control system" means the elements of design and emission strategies developed or calibrated for the purpose of controlling emissions;
"Emission related maintenance" means the maintenance which substantially affects emissions or which is likely to affect emissions deterioration of the vehicle or the engine during normal in-use operation;
"Emission strategy" means an element or set of elements of design that is incorporated into the overall design of an engine system or vehicle and used in controlling emissions;
"Engine after-treatment system family" means a manufacturer’s grouping of engines that comply with the definition of engine family, but which are further grouped into engines utilising a similar exhaust after-treatment system;
"Engine family" means a manufacturer’s grouping of engines which through their design, as defined in paragraph 7. of this Regulation, have similar exhaust emission characteristics;
"Engine system" means the engine, the emission control system and the communication interface (hardware and messages) between the engine system electronic control unit or units (ECU) and any other powertrain or vehicle control unit;
"Engine start" consists of the ignition-On, cranking and start of combustion, and is completed when the engine speed reaches 150 min-1 below the normal, warmed-up idle speed;
"Engine type" means a category of engines which do not differ in essential engine characteristics as set out in Annex 1;
"Exhaust after-treatment system" means a catalyst (oxidation, 3-way or any other), particulate filter, deNO x system, combined deNOx particulate filter, or any other emission reducing device, that is installed downstream of the engine;
"Gaseous pollutants" means the exhaust gas emissions of carbon monoxide, NOx, expressed in NO2 equivalent, hydrocarbons (i.e. total hydrocarbons, non-methane hydrocarbons and methane);
"General Denominator" means a counter indicating the number of times a vehicle has been operated, taking into account general conditions;
"Group of monitors" means, for the purpose of assessing the in-use performance of an OBD engine family, a set of OBD monitors used for determining the correct operation of the emission control system;
"Ignition cycle counter" means a counter indicating the number of engine starts a vehicle has experienced;
"In-Use performance ratio" (IUPR) means the ratio of the number of times that the conditions have existed under which a monitor, or group of monitors, should have detected a malfunction relative to the number of driving cycles relevant for the operation of that monitor or group of monitors;
"Low speed (nlo)" means the lowest engine speed where 50 per cent of the declared maximum power occurs;
"Malfunction" means a failure or deterioration of an engine system, including the OBD system, that might reasonably be expected to lead either to an increase in any of the regulated pollutants emitted by the engine system or to a reduction in the effectiveness of the OBD system;
"Malfunction indicator" (MI) means an indicator which is part of the alert system and which clearly informs the driver of the vehicle in the event of a malfunction;
"Manufacturer" means the person or body who is responsible to the Type
Approval Authority for all aspects of the type approval or authorisation process and for ensuring conformity of production. It is not essential that the person or body be directly involved in all stages of the construction of the vehicle, system, component or separate technical unit which is the subject of the approval process;
"Maximum net power" means the maximum value of the net power measured at full engine load;
"Net power" means the power obtained on a test bench at the end of the crankshaft or its equivalent at the corresponding engine or motor speed with the auxiliaries according to UN Regulation No. 85 and determined under reference atmospheric conditions;
"Non-emission-related maintenance" means the maintenance which does not substantially affect emissions and which does not have a lasting effect on the emissions deterioration of the vehicle or the engine during normal in-use operation once the maintenance is performed;
"On-board diagnostic system" (OBD system) means a system on-board of a vehicle or engine which has the capability of:
(a) Detecting malfunctions, affecting the emission performance of the engine system;
(b) Indicating their occurrence by means of an alert system; and
(c) Identifying the likely area of the malfunction by means of information stored in computer memory and communicating that information off- board;
"OBD engine family" means a manufacturer’s grouping of engine systems having common methods of monitoring and diagnosing emission-related malfunctions;
"Operating sequence" means a sequence consisting of an engine start, an operating period (of the engine), an engine shut-off, and the time until the next start, where a specific OBD monitor runs to completion and a malfunction would be detected if present;
"Original pollution control device" means a pollution control device or an assembly of such devices covered by the type approval granted for the vehicle concerned;
"Parent engine" means an engine selected from an engine family in such a way that its emissions characteristics will be representative for that engine family;
"Particulate after-treatment device" means an exhaust after-treatment system designed to reduce emissions of particulate pollutants (PT) through a mechanical, aerodynamic, diffusional or inertial separation;
"Particulate matter (PM)" means any material collected on a specified filter medium after diluting exhaust with a clean filtered diluent to a temperature between 315 K (42 °C) and 325 K (52 °C); this is primarily carbon, condensed hydrocarbons, and sulphates with associated water;
"Per cent load" means the fraction of the maximum available torque at an engine speed;
"Performance monitoring" means malfunction monitoring, that consists of functionality checks and the monitoring of parameters that are not directly correlated to emission thresholds, and that is done on components or systems to verify that they are operating within the proper range;
"Periodic regeneration" means the regeneration process of an emission control device that occurs periodically in less than 100 hours of normal engine operation;
"Portable emissions measurement system" (PEMS) means a portable emissions measurement system meeting the requirements specified in Appendix 2 to Annex 8 of this Regulation;
"Power take-off unit" means an engine driven output device for the purposes of powering auxiliary, vehicle mounted, equipment;
"Qualified deteriorated component or system" (QDC) means a component or system that has been intentionally deteriorated such as by accelerated ageing or by having been manipulated in a controlled manner and which has been accepted by the Type Approval Authority according to the provisions set out in paragraph 6.3.2. of Annex 9B and paragraph A.8.2.2. of Appendix 8 to Annex 9B to this Regulation for use when demonstrating the OBD performance of the engine system;
"Reagent" means any medium that is stored on-board the vehicle in a tank and provided to the exhaust after-treatment system (if required) upon request of the emission control system;
"Recalibration" means a fine tuning of a natural gas engine in order to provide the same performance (power, fuel consumption) in a different range of natural gas;
"Reference mass" means the mass of the vehicle in running order less the uniform mass of the driver of 75 kg and increased by a uniform mass of 100 kg;
"Replacement pollution control device" means a pollution control device or an assembly of such devices intended to replace an original pollution control device and which can be approved as a separate technical unit;
"Scan-tool" means external test equipment used for standardised off-board communication with the OBD system in accordance with the requirements of this Regulation;
"Service accumulation schedule" means the ageing cycle and the service accumulation period for determining the deterioration factors for the engine- after-treatment system family;
"Tailpipe emissions" means the emission of gaseous and particulate pollutants;
"Tampering" means inactivation, adjustment or modification of the vehicle emissions control or propulsion system, including any software or other logical control elements of those systems, that has the effect, whether intended or not, of worsening the emissions performance of the vehicle;
"Unladen mass" means the mass of the vehicle in running order without the uniform mass of the driver of 75 kg, passengers or load, but with the fuel tank 90 per cent full and the usual set of tools and spare wheel on board, where applicable;
"Useful life" means the relevant period of distance and/or time over which compliance with the relevant gaseous and particulate emission limits has to be assured;
"Vehicle type with regard to emissions" means a group of vehicles which do not differ in essential engine and vehicle characteristics as set out in Annex 1;
"Wall flow Diesel Particulate Filter" means a Diesel Particulate Filter ("DPF") in which all the exhaust gas is forced to flow through a wall which filters out the solid matter;
"Wobbe index (lower Wl; or upper Wu)" means the ratio of the corresponding calorific value of a gas per unit volume and the square root of its relative density under the same reference conditions:
W H gas ρair /ρgas
"λ-shift factor (Sλ)" means an expression that describes the required flexibility of the engine management system regarding a change of the excess-air ratio λ if the engine is fuelled with a gas composition different from pure methane (see Appendix 5 to Annex 4 for the calculation of Sλ).
3.Application for approval
Application for type approval of an engine system or engine family as a separate technical unit
The manufacturer or his authorized representative shall submit to the Type
Approval Authority an application for type approval of an engine system or engine family as a separate technical unit.
The application referred to in paragraph 3.1.1. shall be drawn up in accordance with the model of the information document set out in Annex 1. For that purpose Part 1 of Annex 1 shall apply.
Together with the application, the manufacturer shall provide a documentation package that fully explains any element of design which affects emissions, the emission control strategy of the engine system, the means by which the engine system controls the output variables which have a bearing upon emissions, whether that control is direct or indirect, and fully explains the warning and inducement system required by paragraphs 4. and 5. of Annex 11. The documentation package shall consist of the following parts including the information set out in paragraph 5.1.4.:
(a) A formal documentation package that shall be retained by the Type Approval Authority. The formal documentation package may be made available to interested parties upon request;
(b) An extended documentation package that shall remain confidential. The extended documentation package may be kept by the Type Approval Authority or be retained by the manufacturer, at the discretion of the Type Approval Authority, but shall be made available for inspection by the Type Approval Authority at the time of approval or at any time during the validity of the approval. When the documentation package is retained by the manufacturer, the Type Approval Authority shall take the necessary measures to ensure that the documentation is not being altered after approval.
In addition to the information referred to in paragraph 3.1.3., the manufacturer shall submit the following information:
(a) In the case of positive-ignition engines, a declaration by the manufacturer of the minimum percentage of misfires out of a total number of firing events that either would result in emissions exceeding the limits set out in Annex 9A if that percentage of misfire had been present from the start of the emission test as set out in Annex 4 or could lead to an exhaust catalyst, or catalysts, overheating prior to causing irreversible damage;
(b) A description of the provisions taken to prevent tampering with and modification of the emission control computer(s), including the facility for updating using a manufacturer-approved programme or calibration;
(c) Documentation of the OBD system, in accordance with the requirements set out in paragraph 8. of Annex 9B;
(d) OBD related information for the purpose of access to OBD, in accordance with the requirements of Annex 14 of this Regulation;
(e) A Statement of off-cycle emission compliance, with the requirements of paragraph 5.1.3. and paragraph 10. of Annex 10;
(f) A Statement of OBD in-use performance compliance, with the requirements of Appendix 2 to Annex 9A;
(g) The initial plan for in-service testing according to paragraph 2.4. of Annex 8;
(h) Where appropriate, copies of other type approvals with the relevant data to enable extension of approvals and establishment of deterioration factors.
The manufacturer shall submit to the technical service responsible for the type approval tests an engine or, as appropriate, a parent engine representative of the type to be approved.
Changes to the make of a system, component or separate technical unit that occur after a type approval shall not automatically invalidate a type approval, unless its original characteristics or technical parameters are changed in such a way that the functionality of the engine or pollution control system is affected.
Application for type approval of a vehicle with an approved engine system with regard to emissions
The manufacturer or his authorized representative shall submit to the Type
Approval Authority an application for type approval of a vehicle with an approved engine system with regard to emissions.
The application referred to in paragraph 3.2.1. shall be drawn up in accordance with the model of the information document set out in Part 2 of Annex 1. This application shall be accompanied by a copy of the type approval certificate for the engine system or engine family as a separate technical unit.
The manufacturer shall provide a documentation package that fully explains the elements of the warning and inducement system that is on board of the vehicle and required by Annex 11. This documentation package shall be provided in accordance with paragraph 3.1.3.
In addition to the information referred to in paragraph 3.2.3., the manufacturer shall submit the following information:
(a) A description of the measures taken to prevent tampering with and modification of the vehicle control units covered by this Regulation, including the facility for updating using a manufacturer-approved programme or calibration;
(b) A description of the OBD components on board of the vehicle, in accordance with the requirements of paragraph 8. of Annex 9B;
(c) Information related to the OBD components on board of the vehicle for the purpose of access to OBD;
(d) Where appropriate, copies of other type approvals with the relevant data to enable extension of approvals.
Changes to the make of a system, component or separate technical unit that occur after a type approval shall not automatically invalidate a type approval, unless its original characteristics or technical parameters are changed in such a way that the functionality of the engine or pollution control system is affected.
Application for type approval of a vehicle with regard to emissions
The manufacturer or his authorized representative shall submit to the Type
Approval Authority an application for type approval of a vehicle with regard to emissions.
The application referred to in paragraph 3.3.1. shall be drawn up in accordance with the model of the information document set out in Annex 1. For that purpose Part 1 and Part 2 of that Annex shall apply.
The manufacturer shall provide a documentation package that fully explains any element of design which affects emissions, the emission control strategy of the engine system, the means by which the engine system controls the output variables which have a bearing upon emissions, whether that control is direct or indirect, and fully explains the warning and inducement system required by Annex 11. This documentation package shall be provided in accordance with paragraph 3.1.3.
In addition to the information referred to in paragraph 3.3.3., the manufacturer shall submit the information required by paragraph 3.1.4. (a) to
(h) and paragraph 3.2.4. (a) to (d).
The manufacturer shall submit to the technical service responsible for the type approval tests an engine representative of the type to be approved.
Changes to the make of a system, component or separate technical unit that occur after a type approval shall not automatically invalidate a type approval, unless its original characteristics or technical parameters are changed in such a way that the functionality of the engine or pollution control system is affected.
Application for type approval of a type of replacement pollution control device as a separate technical unit
The manufacturer shall submit to the Type Approval Authority an application for type approval of a type of replacement pollution control device as a separate technical unit.
The application shall be drawn up in accordance with the model of the information document set out in Appendix 1 to Annex 13.
The manufacturer shall submit a Statement of compliance with the requirements on access to OBD information.
The manufacturer shall submit to the technical service responsible for the type approval test the following:
(a) An engine system or engine systems of a type approved in accordance with this Regulation equipped with a new original equipment pollution control device;
(b) One sample of the type of the replacement pollution control device;
(c) An additional sample of the type of the replacement pollution control device, in the case of a replacement pollution control device intended to be fitted to a vehicle equipped with an OBD system.
For the purposes of point (a) of paragraph 3.4.4., the test engines shall be selected by the applicant with the agreement of the Type Approval Authority. The test conditions shall comply with the requirements set out in paragraph 6. of Annex 4. The test engines shall respect the following requirements:
(a) They shall have no emission control system defects;
(b) Any malfunctioning or excessively worn emission-related original part shall be repaired or replaced;
(c) They shall be tuned properly and set to the manufacturer's specification prior to emission testing.
For the purposes of points (b) and (c) of paragraph 3.4.4., the sample shall be clearly and indelibly marked with the applicant's trade name or mark and its commercial designation.
For the purposes of point (c) of paragraph 3.4.4., the sample shall be a qualified deteriorated component.
4.Approval
In order to receive a type approval of an engine system or engine family as a separate technical unit, type approval of a vehicle with an approved engine system with regard to emissions, or a type approval of a vehicle with regard to emissions, the manufacturer shall, in accordance with the provisions of this Regulation demonstrate that the vehicles or engine systems are subject to the tests and comply with the requirements set out in paragraph 5. and Annexes 4, 6, 7, 9A, 9B, 9C, 10, 11, and 12. The manufacturer shall also ensure compliance with the specifications of reference fuels set out in Annex 5.
In order to receive type approval of a vehicle with an approved engine system with regard to emissions or a type approval of a vehicle with regard to emissions the manufacturer shall ensure compliance with the installation requirements set out in paragraph 6.
In order to receive an extension of the type approval of a vehicle with regard to emissions type-approved under this Regulation with a reference mass exceeding 2,380 kg but not exceeding 2,610kg the manufacturer shall meet the requirements set out in Appendix 1 to Annex 12.
Reserved2
Reserved3
In order to receive a type approval of an engine system or engine family as a separate technical unit or a type approval of a vehicle with regard to emissions, the manufacturer shall ensure compliance with the requirements on fuel range for a universal fuel approval or in case of a positive ignition engine fuelled with natural gas and LPG a restricted fuel range approval as specified in paragraph 4.6.
Requirements on universal fuel range type approval
A universal fuel range approval shall be granted subject to the requirements specified in paragraphs 4.6.1. to 4.6.6.1.
The parent engine shall meet the requirements of this Regulation on the appropriate reference fuels specified in Annex 5. Specific requirements shall apply to natural gas fuelled engines, as laid down in paragraph 4.6.3.
If the manufacturer permits to operate the engine family to run on market fuels not covered by the reference fuels included in Annex 5 or the relevant market fuel standards (for example EN 228 CEN standards in the case of unleaded petrol and EN 590 CEN standard in the case of diesel), such as running on B100, the manufacturer shall, in addition to the requirements in paragraph 4.6.1.:
(a) Declare the fuels the engine family is capable to run on in paragraph 3.2.2.2.1. of Part 1 of Annex 1;
(b) Demonstrate the capability of the parent engine to meet the requirements of this Regulation on the fuels declared;
(c) Be liable to meet the requirements of in-service conformity specified in paragraph 9. on the fuels declared, including any blend between the declared fuels and the relevant market fuels and standards.
In the case of a natural gas fuelled engine the manufacturer shall demonstrate the parent engines capability to adapt to any fuel composition that may occur across the market.
This paragraph is reserved for future heavy-duty dual-fuel engine approvals. This paragraph is reserved for alternative provisions relating to alternative light-duty OBD and NOx control requirements.
In the case of natural gas there are generally two types of fuel, high calorific fuel (H-gas) and low calorific fuel (L-gas), but with a significant spread within both ranges; they differ significantly in their energy content expressed by the Wobbe Index and in their λ-shift factor (Sλ). Natural gases with a λ- shift factor between 0.89 and 1.08 (0.89 ≤ Sλ ≤ 1.08) are considered to belong to H-range, while natural gases with a λ-shift factor between 1.08 and 1.19 (1.08 ≤ Sλ ≤ 1.19) are considered to belong to L-range. The composition of the reference fuels reflects the extreme variations of Sλ. The parent engine shall meet the requirements of this Regulation on the reference fuels GR (fuel 1) and G25 (fuel 2), as specified in Annex 5, without any readjustment to the fuelling between the two tests. One adaptation run over one WHTC hot cycle without measurement is permitted after the change of the fuel. After the adaptation run the engine shall be cooled down in accordance with paragraph 7.6.1. of Annex 4.
At the manufacturer's request the engine may be tested on a third fuel (fuel 3) if the λ-shift factor (Sλ) lies between 0.89 (that is the lower range of GR) and 1.19 (that is the upper range of G25), for example when fuel 3 is a market fuel. The results of this test may be used as a basis for the evaluation of the conformity of the production.
In the case of an engine fuelled with natural gas which is self-adaptive for the range of H-gases on the one hand and the range of L-gases on the other hand, and which switches between the H-range and the L-range by means of a switch, the parent engine shall be tested on the relevant reference fuel as specified in Annex 5 for each range, at each position of the switch. The fuels are GR (fuel 1) and G23 (fuel 3) for the H-range of gases and G25 (fuel 2) and G23 (fuel 3) for the L-range of gases. The parent engine shall meet the requirements of this Regulation at both positions of the switch without any readjustment to the fuelling between the two tests at each position of the switch. One adaptation run over one WHTC hot cycle without measurement is permitted after the change of the fuel. After the adaptation run the engine shall be cooled down in accordance with paragraph 7.6.1. of Annex 4.
At the manufacturer's request the engine may be tested on a third fuel instead of G23 (fuel 3) if the λ-shift factor (Sλ) lies between 0.89 (that is the lower range of GR) and 1.19 (that is the upper range of G25), for example when fuel 3 is a market fuel. The results of this test may be used as a basis for the evaluation of the conformity of the production.
In the case of natural gas engines, the ratio of the emission results "r" shall be determined for each pollutant as follows:
emission result on reference fuel 2 emission result on reference fuel 1
or,
emission result on reference fuel 2 emission result on reference fuel 3
and,
emission result on reference fuel 1 emission result on reference fuel 3
In the case of LPG the manufacturer shall demonstrate the parent engines capability to adapt to any fuel composition that may occur across the market. In the case of LPG there are variations in C3/C4 composition. These variations are reflected in the reference fuels. The parent engine shall meet the emission requirements on the reference fuels A and B as specified in Annex 5 without any readjustment to the fuelling between the two tests. One adaptation run over one WHTC hot cycle without measurement is permitted after the change of the fuel. After the adaptation run the engine shall be cooled down in accordance with paragraph 7.6.1. of Annex 4.
The ratio of emission results "r" shall be determined for each pollutant as follows: emission result on reference fuel B emission result on reference fuel A
Requirements on restricted fuel range type approval in case of positive ignition engines fuelled with natural gas or LPG. Fuel range restricted approval shall be granted subject to the requirements specified in paragraphs 4.7.1. to 4.7.2.3.
Exhaust emissions type approval of an engine running on natural gas and laid out for operation on either the range of H-gases or on the range of L-gases.
The parent engine shall be tested on the relevant reference fuel, as specified in Annex 5, for the relevant range. The fuels are G R (fuel 1) and G23 (fuel 3) for the H-range of gases and G25 (fuel 2) and G23 (fuel 3) for the L-range of gases. The parent engine shall meet the requirements of this Regulation without any readjustment to the fuelling between the two tests. One adaptation run over one WHTC hot cycle without measurement is permitted after the change of the fuel. After the adaptation run the engine shall be cooled down in accordance with paragraph 7.6.1. of Annex 4.
At the manufacturer's request the engine may be tested on a third fuel instead of G23 (fuel 3) if the λ-shift factor (Sλ) lies between 0.89 (that is the lower range of GR) and 1.19 (that is the upper range of G25), for example when fuel 3 is a market fuel. The results of this test may be used as a basis for the evaluation of the conformity of the production.
The ratio of emission results "r" shall be determined for each pollutant as follows:
emission result on reference fuel 2 emission result on reference fuel 1
or,
emission result on reference fuel 2 emission result on reference fuel 3
and, emission result on reference fuel 1 emission result on reference fuel 3
On delivery to the customer the engine shall bear a label as specified in paragraph 4.12.8. stating for which range of gases the engine is approved.
Exhaust emissions type approval of an engine running on natural gas or LPG and designed for operation on one specific fuel composition.
The parent engine shall meet the emission requirements on the reference fuels
GR and G25 in the case of natural gas, or the reference fuels A and B in the case of LPG, as specified in Annex 5. Fine-tuning of the fuelling system is allowed between the tests. This fine-tuning will consist of a recalibration of the fuelling database, without any alteration to either the basic control strategy or the basic structure of the database. If necessary the exchange of parts that are directly related to the amount of fuel flow such as injector nozzles is allowed.
At the manufacturer's request the engine may be tested on the reference fuels
GR and G23, or on the reference fuels G25 and G23, in which case the type approval is only valid for the H-range or the L-range of gases respectively.
On delivery to the customer the engine shall bear a label as specified in paragraph 4.12.8. stating for which fuel composition the engine has been calibrated.
Exhaust emissions type approval of a member of a family
With the exception of the case mentioned in paragraph 4.8.2., the type approval of a parent engine shall be extended to all family members, without further testing, for any fuel composition within the range for which the parent engine has been approved (in the case of engines described in paragraph 4.7.2.) or the same range of fuels (in the case of engines described in either paragraph 4.6. or 4.7.) for which the parent engine has been type- approved.
If the technical service determines that, with regard to the selected parent engine the submitted application does not fully represent the engine family defined in Part 1 of Annex 1, an alternative and if necessary an additional reference test engine may be selected by the technical service and tested.
Tables summarising the requirements for approval of NG-Fuelled engines and LPG-Fuelled engines are provided in Appendix 4.
Requirements for approval regarding the on-board diagnostic systems
Manufacturers shall ensure that all engine systems and vehicles are equipped with an OBD system.
The OBD system shall be designed, constructed and installed on a vehicle in accordance with Annex 9A, so as to enable it to identify, record, and communicate the types of deterioration or malfunction specified in that Annex over the entire life of the vehicle.
The manufacturer shall ensure that the OBD system complies with the requirements set out in Annex 9A, including the OBD in-use performance requirements, under all normal and reasonably foreseeable driving conditions, including the conditions of normal use specified in Annex 9B.
When tested with a qualified deteriorated component, the OBD system malfunction indicator shall be activated in accordance with Annex 9B. The OBD system malfunction indicator may also be activated at levels of emissions below the OBD thresholds limits specified in Annex 9A.
The manufacturer shall ensure that the provisions for in-use performance of an OBD engine family laid down in Annex 9A are followed.
The OBD in-use performance related data shall be stored and made available without any encryption through the standard OBD communication protocol by the OBD system in accordance with the provisions of Annex 9A.
If the manufacturer chooses, until the date specified in paragraph 13.2.3. for new type approvals, OBD systems may comply with alternative provisions as specified in Annex 9A and referring to this paragraph.
If the manufacturer chooses, until the date specified in paragraph 13.2.2. for new type approvals, he may use alternative provisions for the monitoring of the Diesel Particulate Filter (DPF) as set out in paragraph 2.3.2.2. of Annex 9A.
Requirements for approval regarding replacement pollution control devices
The manufacturer shall ensure that replacement pollution control devices intended to be fitted to type-approved engine systems or vehicles covered by this Regulation are type-approved, as separate technical units in accordance with the requirements of paragraphs 4.11.2. to 4.11.5. Catalytic converters, deNOx devices and particulate filters shall be considered to be pollution control devices for the purposes of this Regulation.
Original replacement pollution control devices, which fall within the type covered by paragraph 3.2.12. of Part 1 of Annex 1 and are intended for fitment to a vehicle to which the relevant type approval document refers, do not need to comply with all provisions of Annex 13 provided that they fulfil the requirements of paragraphs 2.1., 2.2. and 2.3. of that annex.
The manufacturer shall ensure that the original pollution control device carries identification markings.
The identification markings referred to in paragraph 4.11.3. shall comprise the following:
(a) The vehicle or engine manufacturer's name or trade mark;
(b) The make and identifying part number of the original pollution control device as recorded in the information referred to in paragraph 3.2.12.2. of Part 1 of Annex 1.
Replacement pollution control devices shall only be type approved according to this Regulation once the specific testing requirements are introduced in Annex 13 of this Regulation4.
Approval marks and labelling for engine systems and vehicles
An approval number shall be assigned to each type approved. Its first two digits (at present 06, corresponding to 06 series of amendments) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party shall not assign the same number to another engine type or vehicle type.
Notice of approval or of extension or of refusal of approval or production definitively discontinued of an engine type or vehicle type pursuant to this Regulation shall be communicated to the Parties to the 1958 Agreement which apply this Regulation, by means of a form conforming to the model in Annexes 2A, 2B or 2C, as applicable, to this Regulation. Values measured during the type test shall also be shown.
There shall be affixed, conspicuously and in a readily accessible place to every engine conforming to an engine type-approved under this Regulation, or to every vehicle conforming to a vehicle type-approved under this Regulation, an international approval mark consisting of:
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval5;
The number of this Regulation, followed by the letter "R", a dash and the approval number to the right of the circle prescribed in paragraph 4.12.3.1.
The approval mark shall also contain a dash and an additional character after the approval number, the purpose of which is to distinguish the stage for which the approval has been granted according paragraph 13.2. and communicated in Table 1 in Annex 3.
For diesel fuelled CI engines the approval mark shall contain the letter "D" after the national symbol, the purpose of which is to distinguish the type of engine for which the approval has been granted.
For ethanol (ED95) fuelled CI engines the approval mark shall contain the letters "ED" after the national symbol, the purpose of which is to distinguish the type of engine for which the approval has been granted.
For ethanol (E85) fuelled PI engines the approval mark shall contain "E85" after the national symbol, the purpose of which is to distinguish the type of engine for which the approval has been granted.
For petrol fuelled PI engines the approval mark shall contain the letter "P" after the national symbol, the purpose of which is to distinguish the type of engine for which the approval has been granted.
Ageing procedure in Annex 13 needs to be finalised before type approvals can be drafted. The distinguishing numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.2/Amend.1 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions
For LPG fuelled PI engines the approval mark shall contain the letter "Q" after the national symbol, the purpose of which is to distinguish the type of engine for which the approval has been granted.
For natural gas fuelled engines the approval mark shall contain a letter/s after the national symbol, the purpose of which is to distinguish which range of gases the approval has been granted. This letter/s will be as follows:
(a) H in case of the engine being approved and calibrated for the H-range of gases;
(b) L in case of the engine being approved and calibrated for the L-range of gases;
(c) HL in case of the engine being approved and calibrated for both the H-range and L-range of gases;
(d) Ht in case of the engine being approved and calibrated for a specific gas composition in the H-range of gases and transformable to another specific gas in the H-range of gases by fine tuning of the engine fuelling;
(e) Lt in case of the engine being approved and calibrated for a specific gas composition in the L-range of gases and transformable to another specific gas in the L-range of gases after fine tuning of the engine fuelling;
(f) HLt in the case of the engine being approved and calibrated for a specific gas composition in either the H-range or the L-range of gases and transformable to another specific gas in either the H-range or the L-range of gases by fine tuning of the engine fuelling.
If the vehicle or engine conforms to an approved type under one or more other Regulations annexed to the Agreement, in the country which has granted approval under this Regulation, the symbol prescribed in paragraph 4.12.3.1. does not need to be repeated. In such a case, the Regulation and approval numbers and the additional symbols of all the Regulations under which approval has been granted under this Regulation shall be placed in vertical columns to the right of the symbol prescribed in paragraph 4.12.3.1.
The approval mark shall be placed close to or on the data plate affixed by the manufacturer to the approved type.
Annex 3 to this Regulation gives examples of arrangements of approval marks.
The engine approved as a technical unit shall bear, in addition to the approved mark:
The trademark or trade name of the manufacturer of the engine;
The manufacturer's commercial description.
Labels
In the case of natural gas and LPG fuelled engines with a fuel range restricted type approval, the following labels are applicable:
Content
The following information shall be given: In the case of paragraph 4.7.1.4., the label shall state "ONLY FOR USE WITH NATURAL GAS RANGE H". If applicable, "H" is replaced by "L". In the case of paragraph 4.7.2.3., the label shall state "ONLY FOR USE WITH NATURAL GAS SPECIFICATION ..." or "ONLY FOR USE WITH LIQUEFIED PETROLEUM GAS SPECIFICATION ...", as applicable. All the information in the relevant table(s) in Annex 5 shall be given with the individual constituents and limits specified by the engine manufacturer. The letters and figures shall be at least 4 mm in height. Note: If lack of space prevents such labelling, a simplified code may be used. In this event, explanatory notes containing all the above information shall be easily accessible to any person filling the fuel tank or performing maintenance or repair on the engine and its accessories, as well as to the authorities concerned. The site and content of these explanatory notes will be determined by agreement between the manufacturer and the Type Approval Authority.
Properties
Labels shall be durable for the useful life of the engine. Labels shall be clearly legible and their letters and figures shall be indelible. Additionally, labels shall be attached in such a manner that their fixing is durable for the useful life of the engine, and the labels cannot be removed without destroying or defacing them.
Placing
Labels shall be secured to an engine part necessary for normal engine operation and not normally requiring replacement during engine life. Additionally, these labels shall be located so as to be readily visible after the engine has been completed with all the auxiliaries necessary for engine operation.
In case of an application for approval for a vehicle type in respect of its engine, the marking specified in paragraph 4.12.8. shall also be placed close to fuel filling aperture.
In case of an application for approval for a vehicle type with an approved engine, the marking specified in paragraph 4.12.8. shall also be placed close to the fuel filling aperture.
5.Requirements and tests
General
Manufacturers shall equip vehicles and engines so that the components likely to affect emissions are designed, constructed and assembled so as to enable the vehicle or engine, in normal use, to comply with this Regulation and its implementing measures.
The manufacturer shall take technical measures so as to ensure that the tailpipe emissions are effectively limited, in accordance with this Regulation, throughout the normal life of the vehicle and under normal conditions of use.
Those measures referred to in paragraph 5.1.2. shall include ensuring that the security of hoses, joints and connections, used within the emission control systems, are constructed so as to conform to the original design intent.
The manufacturer shall ensure that the emissions test results comply with the applicable limit value under the test conditions specified in this Regulation.
Any engine system and any element of design liable to affect the emission of gaseous and particulate pollutants shall be designed, constructed, assembled and installed so as to enable the engine, in normal use, to comply with the provisions of this Regulation. The manufacturer shall also ensure compliance with off-cycle requirements set out in paragraph 5.1.3. and Annex 10.
The use of defeat strategies that reduce the effectiveness of emission control equipment shall be prohibited.
In order to receive a type approval in the case of a petrol or E85 fuelled engine, the manufacturer shall ensure that the specific requirements for inlets to fuel tanks for petrol and E85 fuelled vehicles laid down in paragraph 6.3. are fulfilled.
Requirements to limit off-cycle emissions
When meeting the requirements of paragraph 5.1.2., the technical measures undertaken shall take the following into account:
(a) The general requirements, including the performance requirements and the prohibition of defeat strategies, as specified in Annex 10;
(b) The requirements to effectively limit the tailpipe emissions under the range of ambient conditions under which the vehicle may be expected to operate, and under the range of operating conditions that may be encountered;
(c) The requirements with respect to off-cycle laboratory testing at type approval;
(d) The requirements with respect to the PEMS demonstration test at type approval and any additional requirements with respect to off-cycle in- use vehicle testing, as provided for in this Regulation;
(e) The requirement for the manufacturer to provide a statement of compliance with the requirements limiting off-cycle emissions.
The manufacturer shall fulfil the specific requirements, together with the associated test procedures, set out in Annex 10.
Documentation requirements
The documentation package required by paragraph 3. enabling the Type
Approval Authority to evaluate the emission control strategies and the systems on-board the vehicle and engine to ensure the correct operation of NOx control measures shall be made available in the two following parts:
(a) The "formal documentation package" that may be made available to interested parties upon request;
(b) The "extended documentation package" that shall remain strictly confidential.
The formal documentation package may be brief, provided that it exhibits evidence that all outputs permitted by a matrix obtained from the range of control of the individual unit inputs have been identified. The documentation shall describe the functional operation of the inducement system required by Annex 11, including the parameters necessary for retrieving the information associated with that system. This material shall be retained by the Type Approval Authority.
The extended documentation package shall include information on the operation of all AES and BES, including a description of the parameters that are modified by any AES and the boundary conditions under which the AES operate, and indication of which AES and BES are likely to be active under the conditions of the test procedures set out in Annex 10. The extended documentation package shall include a description of the fuel system control logic, timing strategies and switch points during all modes of operation. It shall also include a full description of the inducement system required in Annex 11, including the associated monitoring strategies.
The extended documentation package shall remain strictly confidential. It may be kept by the Type Approval Authority, or, at the discretion of the Type Approval Authority, may be retained by the manufacturer. In the case the manufacturer retains the documentation package, that package shall be identified and dated by the Type Approval Authority once reviewed and approved. It shall be made open for inspection by the Type Approval Authority at the time of approval or at any time during the validity of the approval.
Provisions for electronic system security
The general requirements, including the specific requirements for electronic system security, shall be those set out in paragraph 4. of Annex 9B of this Regulation and those described in paragraph 2. of Annex 9A.
Specifications concerning the emission of gaseous and particulate pollutants
In undertaking the tests set out in Annex 4 the gaseous and particulate matter emissions shall not exceed the amounts shown in Table 1.
For positive ignition engines subject to the test set out in Annex 6, the maximum permissible carbon monoxide content in the exhaust gases at normal engine idling speed shall be that stated by the vehicle manufacturer. However, the maximum carbon monoxide content shall not exceed 0.3 per cent vol. At high idle speed, the carbon monoxide content by volume of the exhaust gases shall not exceed 0.2 per cent vol., with the engine speed being at least 2,000 min-1 and Lambda being 1 ± 0.03 or in accordance with the specifications of the manufacturer.
In the case of a closed crankcase, manufacturers shall ensure that for the tests set out in paragraphs 6.10. and 6.11. of Annex 4, the engine’s ventilation system does not permit the emission of any crankcase gases into the atmosphere. If the crankcase is of an open type, the emissions shall be measured and added to the tailpipe emissions, following the provisions set out in paragraph 6.10. of Annex 4.
Emission limits
provides the emissions limits that apply to this Regulation.
Emission Limits
Limit values
CO THC NMHC CH4 NOX NH3 PM mass PM number
(mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) (ppm) (mg/kWh) (#/kWh)
WHSC (CI) 1,500 130 400 10 10 8.0 x 1011
WHTC (CI) 4,000 160 460 10 10 6.0 x 1011
WHTC (PI) 4,000 160 500 460 10 10
Notes:
PI = Positive Ignition
CI = Compression IgnitionDurability and deterioration factors
The manufacturer shall determine deterioration factors that will be used to demonstrate that the gaseous and particulate emissions of an engine family or engine- after-treatment system family remain in conformity with the emission limits set out in paragraph 5.3. over the normal useful life periods set out below. The procedures for demonstrating the compliance of an engine system or engine-after-treatment system family over the normal useful life are set out in Annex 7. The mileage and period of time by reference to which the tests for durability of pollution control devices undertaken for type approval and testing of conformity of in-service vehicles or engines are to be carried out shall be the following:
(a) 160,000 km or five years, whichever is the sooner, in the case of engines fitted to vehicles of category M1, N1 and M2;
(b) 300,000 km or six years, whichever is the sooner, in the case of engines fitted to vehicles of category N2, N3 with a maximum technically permissible mass not exceeding 16 tonnes and M3 Class I, Class II and Class A, and Class B with a maximum technically permissible mass not exceeding 7.5 tonnes;
(c) 700,000 km or seven years, whichever is the sooner, in the case of engines fitted to vehicles of category N3 with a maximum technically permissible mass exceeding 16 tonnes and M3, Class III and Class B with a maximum technically permissible mass exceeding 7.5 tonnes.
Requirements to ensure correct operation of NOx control measures
When applying for type approval, manufacturers shall present to the Type
Approval Authority information showing that the NOx system retains its emission control function during all conditions regularly pertaining in the region (e.g. European Union), especially at low temperatures. In addition, manufacturers shall provide the Type Approval Authority with information on the operating strategy of any exhaust gas recirculation system (EGR), including its functioning at low ambient temperatures.
This information shall also include a description of any effects on emissions of operating the system under low ambient temperatures. Information on the tests and procedures for fulfilling these requirements is provided in Annex 11.
6.Installation on the vehicle
The engine installation on the vehicle shall be performed in such a way as to ensure that the type approval requirements are met. The following characteristics in respect to the type approval of the engine shall be taken into consideration:
Intake depression shall not exceed that declared for the engine type approval in Part 1 of Annex 1;
Exhaust back pressure shall not exceed that declared for the engine type approval in Part 1 of Annex 1;
Power absorbed by the auxiliaries needed for operating the engine shall not exceed that declared for the engine type approval in Part 1 of Annex 1;
The characteristics of the exhaust after-treatment system shall be in accordance with those declared for the engine type approval in Part 1 of Annex 1.
Installation of a type-approved engine on a vehicle
The installation of an engine type-approved as a separate technical unit on a vehicle shall, in addition, comply with the following requirements:
(a) As regard to the compliance of the OBD system, the installation shall, according to Appendix 1 of Annex 9B, meet the manufacturer's installation requirements as specified in Part 1 of Annex 1;
(b) As regard to the compliance of the system ensuring the correct operation of NOx control measures, the installation shall, according to Appendix 4 of Annex 11, meet the manufacturer's installation requirements as specified in Part 1 of Annex 1.
Inlet to fuel tanks in the case of a petrol or E85 fuelled engine
The inlet orifice of the petrol or E85 tank shall be designed so it prevents the tank from being filled from a fuel pump delivery nozzle that has an external diameter of 23.6 mm or greater.
Paragraph 6.3.1. shall not apply to a vehicle for which both of the following conditions are satisfied:
(a) The vehicle is designed and constructed so that no device designed to control the emission of gaseous pollutants is adversely affected by leaded petrol;
(b) The vehicle is conspicuously, legibly and indelibly marked with the symbol for unleaded petrol specified in ISO 2575:2004 in a position immediately visible to a person filling the fuel tank. Additional marking are permitted.
Provision shall be made to prevent excess evaporative emissions and fuel spillage caused by a missing fuel filler cap. This may be achieved by using one of the following:
(a) An automatically opening and closing, non-removable fuel filler cap;
(b) Design features which avoid excess evaporative emissions in the case of a missing fuel filler cap;
(c) Or in case of M1 or N1 vehicles, any other provision which has the same affect. Examples may include, but are not limited to, a tethered filler cap, a chained filler cap or one utilizing the same locking key for the filler cap as for the vehicle’s ignition. In this case the key shall be removable from the filler cap only in the locked condition.
7.Engine family
Parameters defining the engine family
The engine family, as determined by the engine manufacturer shall comply with paragraph 5.2. of Annex 4.
Choice of the parent engine
The parent engine of the family shall be selected in accordance with the requirements set out in paragraph 5.2.4. of Annex 4.
Parameters for defining an OBD-engine family
The OBD-engine family shall be determined by basic design parameters that shall be common to engine systems within the family, in accordance with paragraph 6.1. of Annex 9B.
8.Conformity of production
Every engine or vehicle bearing an approval mark as prescribed under this Regulation shall be so manufactured as to conform, with regard to the description as given in the approval form and its annexes, to the approved type. The conformity of production procedures shall comply with those set out in Appendix 2 to the 1958 Agreement (E/ECE/324//E/ECE/TRANS/505/Rev.2), with the following requirements set out in paragraphs 8.2. to 8.5.
Conformity of production shall be checked on the basis of the description in the type approval certificates set out in Annexes 2A, 2B and 2C, as applicable.
Conformity of production shall be assessed in accordance with the specific conditions laid down in this paragraph and the relevant statistical methods laid down in Appendices 1, 2 and 3.
General requirements
In applying Appendices 1, 2 or 3, the measured emission of the gaseous and particulate pollutants from engines subject to checking for conformity of production shall be adjusted by application of the appropriate deterioration factors (DF’s) for that engine as recorded in the Addendum to the type approval certificate granted in accordance with this Regulation.
The provisions set out in Appendix 2 to the 1958 Agreement )E/ECE/324//E/ECE/TRANS/505/Rev.2) shall be applicable where the approval authorities are not satisfied with the auditing procedure of the manufacturer.
All engines subject to tests shall be randomly taken from the series production.
Emissions of pollutants
If emissions of pollutants are to be measured and an engine type approval has had one or more extensions, the tests shall be carried out on the engines described in the information package relating to the relevant extension.
Conformity of the engine subjected to a pollutant test: After submission of the engine to the authorities, the manufacturer may not carry out any adjustment to the engines selected.
Three engines shall be taken from the series production of the engines under consideration. Engines shall be subjected to testing on the WHTC and on the WHSC, if applicable, for the checking of the production conformity. The limit values shall be those set out in paragraph 5.3.
Where the Type Approval Authority is satisfied with the production standard deviation given by the manufacturer in accordance with Appendix 2 to the 1958 Agreement (E/ECE/324//E/ECE/TRANS/505/Rev.2), the tests shall be carried out according to Appendix 1. Where the Type Approval Authority is not satisfied with the production standard deviation given by the manufacturer in accordance with Appendix 2 to the 1958 Agreement (E/ECE/324//E/ECE/TRANS/505/Rev.2), the tests shall be carried out according to Appendix 2. At the manufacturer’s request, the tests may be carried out in accordance with Appendix 3.
On the basis of tests of the engine by sampling as set out in paragraph 8.3.2.2., the series production of the engines under consideration is regarded as conforming where a pass decision is reached for all the pollutants and as non-conforming where a fail decision is reached for one pollutant, in accordance with the test criteria applied in the appropriate Appendix. When a pass decision has been reached for one pollutant, this decision may not be changed as a consequence of a result from any additional tests made in order to reach a decision for the other pollutants. If a pass decision is not reached for all the pollutants and if no fail decision is reached for any pollutant, a test is carried out on another engine (see
The tests shall be carried out on newly manufactured engines.
At the request of the manufacturer, the tests may be carried out on engines which have been run-in, up to a maximum of 125 hours. In this case, the running-in procedure shall be conducted by the manufacturer who shall undertake not to make any adjustments to those engines.
When the manufacturer requests to conduct a running-in procedure in accordance with paragraph 8.3.3.1., it may be carried out on either of the following:
(a) All the engines that are tested;
(b) The first engine tested, with the determination of an evolution coefficient as follows:
(i) The pollutant emissions shall be measured both on the newly manufactured engine and before the maximum of 125 hours set in paragraph 8.3.3.1. on the first engine tested;
(ii) The evolution coefficient of the emissions between the two tests shall be calculated for each pollutant: Emissions on second test/Emissions first test; The evolution coefficient may have a value less than one. The subsequent test engines shall not be subjected to the running-in procedure, but their emissions when newly manufactured shall be modified by the evolution coefficient. In this case, the values to be taken shall be the following:
(a) For the first engine, the values from the second test;
(b) For the other engines, the values when newly manufactured multiplied by the evolution coefficient.
For diesel, ethanol (ED95), petrol, E85 and LPG fuelled engines, all these tests may be conducted with the applicable market fuels. However, at the manufacturer’s request, the reference fuels described in Annex 5 may be used. This implies tests, as described in paragraph 4., with at least two of the reference fuels for each gas engine.
For natural gas fuelled engines, all these tests may be conducted with market fuel in the following way:
(a) For H marked engines with a market fuel within the H-range (0.89 ≤ Sλ ≤ 1.00);
(b) For L marked engines with a market fuel within the L-range (1.00 ≤ Sλ ≤ 1.19);
(c) For HL marked engines with a market fuel within the extreme range of the λ-shift factor (0.89 ≤ Sλ ≤ 1.19). However, at the manufacturer’s request, the reference fuels described in Annex 5 may be used. This implies tests as described paragraph 4.
In the case of dispute caused by the non-compliance of gas fuelled engines when using a market fuel, the tests shall be performed with a reference fuel on which the parent engine has been tested, or with the possible additional fuel 3, as referred to in paragraphs 4.6.4.1. and 4.7.1.2., on which the parent engine may have been tested. Then, the result shall be converted by a calculation, applying the relevant factors «r», «ra» or «rb» as described in paragraphs 4.6.5., 4.6.6.1. and 4.7.1.3. If r, r a or rb are less than 1, no correction shall take place. The measured results and the calculated results shall demonstrate that the engine meets the limit values with all relevant fuels (fuels 1, 2 and, if applicable, fuel 3 in the case of natural gas engines, and fuels A and B in the case of LPG engines).
Tests for conformity of production of a gas fuelled engine laid out for operation on one specific fuel composition shall be performed on the fuel for which the engine has been calibrated.
On-Board Diagnostics (OBD)
When the Type Approval Authority determines that the quality of production seems unsatisfactory, it may request a verification of the conformity of production of the OBD system. Such verification shall be carried out in accordance with the following: An engine shall be randomly taken from series production and subjected to the tests described in Annex 9B. The tests may be carried out on an engine that has been run-in up to a maximum of 125 hours.
The production is deemed to conform if this engine meets the requirements of the tests described in Annex 9B.
If the engine taken from the series production does not satisfy the requirements of paragraph 8.4.1., a further random sample of four engines shall be taken from the series production and subjected to the tests described in Annex 9B. The tests may be carried out on engines that have been run-in, up to a maximum of 125 hours.
The production is deemed to conform if at least three engines out of the further random sample of four engines meet the requirements of the tests described in Annex 9B.
Electronic control unit (ECU) information required for in-service testing
The availability of the data stream information requested in paragraph 9.4.2.1. according to the requirements of paragraph 9.4.2.2. shall be demonstrated by using an external OBD scan-tool as described in Annex 9B.
In the case where this information cannot be retrieved in a proper manner while the scan-tool is working properly according to Annex 9B, the engine shall be considered as non-compliant.
The conformity of the ECU torque signal with the requirements of paragraphs 9.4.2.2. and 9.4.2.3. shall be demonstrated by performing the WHSC test according to Annex 4.
In the case where the test equipment does not match the requirements specified in Regulation No. 85 concerning auxiliaries, the measured torque shall be corrected in accordance to the correction method set out in Annex 4.
The conformity of the ECU torque signal shall be considered sufficient if the calculated torque remains within the tolerances specified in paragraph 9.4.2.5.
The availability and conformity checks of the ECU information required for in-service testing shall be performed by the manufacturer on a regular basis on each produced engine-type within each produced engine-family.
The results of the manufacturer’s survey shall be made available to the Type
Approval Authority at its request.
At the request of the Type Approval Authority, the manufacturer shall demonstrate the availability or the conformity of the ECU information in serial production by performing the appropriate testing referred to in paragraphs 8.5.1. to 8.5.4. on a sample of engines selected from the same engine type. The sampling rules including sampling size and statistical pass- fail criteria shall be those specified in paragraphs 8.1. to 8.3. for checking the conformity of emissions.
9.Conformity of in-service vehicles/engines
Introduction
This paragraph sets out the in-service conformity requirements for vehicles type-approved to this Regulation.
In-service conformity
Measures to ensure in-service conformity of vehicles or engine systems type- approved under this Regulation shall be taken in accordance with Appendix 2 to the 1958 Agreement (E/ECE/324//E/ECE/TRANS/505/Rev.2) and complying with the requirements of Annex 8 of this Regulation in the case of vehicles or engine systems type-approved under this Regulation.
The technical measures taken by the manufacturer shall be such as to ensure that the tailpipe emissions are effectively limited, throughout the normal life of the vehicles under normal conditions of use. The conformity with the provisions of this Regulation shall be checked over the normal useful life of an engine system installed in a vehicle under normal conditions of use as specified in Annex 8 of this Regulation.
The manufacturer shall report the results of the in-service testing to the Type
Approval Authority which granted the original type approval in accordance with the initial plan submitted at type approval. Any deviation from the initial plan shall be justified to the satisfaction of the Type Approval Authority.
If the Type Approval Authority which granted the original type approval is not satisfied with the manufacturer’s reporting in accordance with paragraph 10. of Annex 8, or has reported evidence of unsatisfactory in- service conformity, the authority may order the manufacturer to run a test for confirmatory purposes. The Type Approval Authority shall examine the confirmatory test report supplied by the manufacturer.
Where the Type Approval Authority which granted the original type approval is not satisfied with the results of in-service tests or confirmatory tests in accordance with the criteria set out in Annex 8, or based on in-service testing conducted by a Contracting Party, it shall require the manufacturer to submit a plan of remedial measures to remedy the non-conformity in accordance with paragraph 9.3. of this Regulation and paragraph 9. of Annex 8.
Any Contracting Party may conduct and report its own surveillance testing, based on the in-service conformity testing procedure set out in Annex 8. Information on the procurement, maintenance, and manufacturer’s participation in the activities shall be recorded. On request by a Type Approval Authority, the Type Approval Authority that granted the original type approval shall provide the necessary information about the type approval to enable testing in accordance with the procedure set out in Annex 8.
If a Contracting Party demonstrates that an engine or vehicle type does not conform to the applicable requirements of this paragraph (i.e. paragraph 9.2.) and Annex 8, it shall notify through its own Type Approval Authority without delay the Type Approval Authority which granted the original type approval. On receipt of such a request, the Type Approval Authority concerned shall take the requisite action as soon as possible and in any case within six months of the date of the request. Following that notification the Type Approval Authority of the Contracting Party which granted the original type approval shall promptly inform the manufacturer that an engine or vehicle type fails to satisfy the requirements of these provisions.
Following the notification referred to in paragraph 9.2.7. and in cases where earlier in-service conformity testing showed conformity, the Type Approval Authority which granted the original type approval may require the manufacturer to perform additional confirmatory tests after consultation with the experts of the Contracting Party that reported the failing vehicle. If no such test data is available, the manufacturer shall, within 60 working days after receipt of the notification referred to in paragraph 9.2.7., either submit to the Type Approval Authority which granted the original type approval a plan of remedial measures in accordance with paragraph 9.3. or
perform additional in-service conformity testing with an equivalent vehicle to verify whether the engine or vehicle type fails the requirements. In the case where the manufacturer can demonstrate to the satisfaction of the Type Approval Authority that further time is required to perform additional testing, an extension may be granted.
Experts of the Contracting Party that reported the failing engine or vehicle type in accordance with paragraph 9.2.7. shall be invited to witness the additional in-service conformity tests referred to in paragraph 9.2.8. Additionally, the results of the tests shall be reported to that Contracting Party and the approval authorities. If these in-service conformity tests or confirmatory tests confirm the non- conformance of the engine or vehicle type, the Type Approval Authority shall require the manufacturer to submit a plan of remedial measures to remedy the non-conformity. The plan of remedial measures shall comply with the provisions of paragraph 9.3. of this Regulation and paragraph 9. of Annex 8. If those in-service conformity tests or confirmatory tests show conformity, the manufacturer shall submit a report to the Type Approval Authority which granted the original type approval. The report shall be submitted by the Type Approval Authority which granted the original type approval to the Contracting Party that reported the failing vehicle type and the Type Approval Authorities. It shall contain the test results according to paragraph
of Annex 8.
The Type Approval Authority which granted the original type approval shall keep the Contracting Party which had established that the engine or vehicle type did not conform to the applicable requirements informed of the progress and results of the discussions with the manufacturer, the verification tests and the remedial measures.
Remedial measures
On request of the Type Approval Authority and following in-service testing in accordance with paragraph 9.2., the manufacturer shall submit the plan of remedial measures to the Type Approval Authority no later than 60 working days after receipt of the notification from the Type Approval Authority. Where the manufacturer can demonstrate to the satisfaction of the Type Approval Authority that further time is required to investigate the reason for the non-compliance in order to submit a plan of remedial measures, an extension may be granted.
The remedial measures shall apply to all engines in service belonging to the same engine families or OBD engine families and be extended also to engine families or OBD engine families which are likely to be affected with the same defects. The need to amend the type approval documents shall be assessed by the manufacturer and the result reported to the Type Approval Authority.
The Type Approval Authority shall consult the manufacturer in order to secure agreement on a plan of remedial measures and on executing the plan. If the Type Approval Authority which granted the original type approval establishes that no agreement can be reached, it shall take the necessary measures, including, where necessary, the withdrawal of type approval, to ensure that production vehicles, systems, components or separate technical
units, as the case may be, are brought into conformity with the approved type. The Type Approval Authority shall advise the Type Approval Authorities of the other contracting parties of the measures taken. If the type approval is withdrawn, the Type Approval Authority shall inform the Approval Authorities of the other contracting parties within 20 working days of the withdrawal and of the reasons therefor.
The Type Approval Authority shall within 30 working days from the date on which it has received the plan of remedial measures from the manufacturer, approve or reject the plan of remedial measures. The Type Approval Authority shall within the same time also notify the manufacturer and all Contracting Parties of its decision to approve or reject the plan of remedial measures.
The manufacturer shall be responsible for the execution of the approved plan of remedial measures.
The manufacturer shall keep a record of every engine system or vehicle recalled and repaired or modified and of the workshop which performed the repair. The Type Approval Authority shall have access to that record on request during the execution and for a period of 5 years after the completion of the execution of the plan.
Any repair or modification referred to in paragraph 9.3.6. shall be recorded in a certificate supplied by the manufacturer to the owner of the engine or vehicle.
Requirements and tests for in-service testing
Introduction
This paragraph (paragraph 9.4.) sets out the specifications and tests of the ECU data at type approval for the purpose of in-service testing.
General requirements
For the purpose of in-service testing, the calculated load (engine torque as a percentage of maximum torque and the maximum torque available at the current engine speed), the engine speed, the engine coolant temperature, the instantaneous fuel consumption, and the reference maximum engine torque as a function of engine speed shall be made available by the OBD system in real time and at a frequency of at least 1 Hz, as mandatory data stream information.
The output torque may be estimated by the ECU using built-in algorithms to calculate the produced internal torque and the friction torque.
The engine torque in Nm resulting from the above data stream information shall permit a direct comparison with the values measured when determining the engine power according to Regulation No. 85. In particular, any eventual corrections as regards auxiliaries shall be included in the above data stream information.
Access to the information required in paragraph 9.4.2.1. shall be provided in accordance with the requirements set out in Annex 9A and with the standards referred to in Appendix 6 to Annex 9B.
The average load at each operating condition in Nm calculated from the information requested in paragraph 9.4.2.1. shall not differ from the average measured load at that operating condition by more than:
(a) 7 per cent when determining the engine power according to Regulation No. 85;
(b) 10 per cent when performing the World Harmonised Steady state Cycle (hereinafter "WHSC") test according to Annex 4, paragraph 7.7. Regulation No. 85 allows the actual maximum load of the engine to differ from the reference maximum load by 5 per cent in order to address the manufacturing process variability. This tolerance is taken into account in the above values.
External access to the information required in paragraph 9.4.2.1. shall not influence the vehicle emissions or performance.
Verification of the availability and conformity of the ECU information required for in-service testing
The availability of the data stream information required in paragraph 9.4.2.1., according to the requirements set out in paragraph 9.4.2.2., shall be demonstrated by using an external OBD scan-tool as described in Annex 9B.
In the case where this information cannot be retrieved in a proper manner, using a scan-tool that is working properly, the engine is considered as non- compliant.
The conformity of the ECU torque signal to the requirements of paragraphs 9.4.2.2. and 9.4.2.3. shall be demonstrated with the parent engine of an engine family when determining the engine power according to Regulation No. 85 and when performing the WHSC test according to Annex 4 paragraph 7.7. and off-cycle laboratory testing at type approval according to paragraph 7. of Annex 10. 9.4.3.3.1 The conformity of the ECU torque signal to the requirements of paragraphs 9.4.2.2. and 9.4.2.3. shall be demonstrated for each engine family member when determining the engine power according to Regulation No. 85. For this purpose additional measurements shall be performed at several part load and engine speed operating points (for example at the modes of the WHSC and some additional random points).
In the case where the engine under test does not match the requirements set out in Regulation No. 85 concerning auxiliaries, the measured torque shall be corrected in accordance to the correction method for power as set out in Annex 4, paragraph 6.3.5.
The conformity of the ECU torque signal is considered to be demonstrated if the torque signal remains within the tolerances set out in paragraph 9.4.2.5.
10.Penalties for non-conformity of production
The approval granted in respect of an engine or vehicle type pursuant to this Regulation may be withdrawn if the requirements laid down in paragraph 8.1. are not complied with, or if the engine(s) or vehicle(s) taken fail to pass the tests prescribed in paragraph 8.3.
If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously granted, it shall forthwith so notify the other Contracting Parties applying this Regulation by means of a communication form conforming to the model in Annexes 2A, 2B or 2C to this Regulation.
Modification and extension of approval of the approved type
Every modification of the approved type shall be notified to the Type
Approval Authority which approved the type. The Type Approval Authority may then either:
Consider that the modifications made are unlikely to have an appreciable adverse effect and that in any case the modified type still complies with the requirement; or
Require a further test report from the Technical Service conducting the tests.
Confirmation or refusal of approval, specifying the alterations, shall be communicated by the procedure specified in paragraph 4.12.2. to the Contracting Parties to the Agreement applying this Regulation.
The Type Approval Authority issuing the extension of approval shall assign a series number for such an extension and inform thereof the other Parties to the 1958 Agreement applying this Regulation by means of a communication form conforming to the model in Annexes 2A, 2B or 2C to this Regulation.
12.Production definitively discontinued
If the holder of the approval completely ceases to manufacture the type approved in accordance with this Regulation, he shall so inform the Type Approval Authority which granted the approval. Upon receiving the relevant communication that Type Approval Authority shall inform thereof the other Parties to the 1958 Agreement which apply this Regulation by means of a communication form conforming to the model in Annexes 2A, 2B or 2C to this Regulation.
13.Transitional provisions
General provisions
As from the official date of entry into force of the 06 series of amendments, no Contracting Party applying this Regulation shall refuse to grant approval under this Regulation as amended by the 06 series of amendments.
As from the date of entry into force of the 06 series of amendments, Contracting Parties applying this Regulation shall grant ECE approvals only if the engine meets the requirements of this Regulation as amended by the 06 series of amendments.
New type approvals
Contracting Parties applying this Regulation shall, from the date of entry into force of the 06 series of amendments to this Regulation, grant an ECE approval to an engine system or vehicle only if it complies with:
(a) The requirements of paragraph 4.1. of this Regulation;
(b) The performance monitoring requirements of paragraph 2.3.2.2. of Annex 9A;
(c) The NOx OTL monitoring requirements as set out in the row "phase in period" of the Tables 1 and 2 of Annex 9A;
(d) The Reagent quality and consumption "phase-in" requirements as set out in paragraphs 7.1.1.1. and 8.4.1.1. of Annex 11.
In accordance with the requirements of paragraph 6.4.4. of Annex 9A manufacturers are exempted from providing a statement of OBD in-use Performance compliance.
Contracting Parties applying this Regulation shall, from 1 September 2014, grant an ECE approval to an engine system or vehicle only if it complies with:
(a) The requirements of paragraph 4.1. of this Regulation;
(b) The PM Mass OTL monitoring requirements as set out in the row "phase in period" of Table 1 of Annex 9A;
(c) The NOx OTL monitoring requirements as set out in the row "phase in period" of Tables 1 and 2 of Annex 9A;
(d) The Reagent quality and consumption "phase-in" requirements as set out in paragraphs 7.1.1.1. and 8.4.1.1. of Annex 11.
In accordance with the requirements of paragraph 6.4.4. of Annex 9A manufacturers are exempted from providing a statement of OBD in-use Performance compliance.
Contracting Parties applying this Regulation shall, from 31 December 2015, grant an ECE approval to an engine system or vehicle only if it complies with:
(a) The requirements of paragraph 4.1. of this Regulation;
(b) The PM Mass OTL monitoring requirements as set out in the row "general requirements" of Table 1 of Annex 9A;
(c) The NOx OTL monitoring requirements as set out in the row "general requirements" of Tables 1 and 2 of Annex 9A;
(d) The Reagent quality and consumption "general" requirements as set out in paragraphs 7.1.1. and 8.4.1. of Annex 11;
(e) The requirements regarding the plan and implementation of the monitoring techniques according to paragraphs 2.3.1.2. and 2.3.1.2.1. of Annex 9A;
(f) The requirements of paragraph 6.4.1. of Annex 9A for providing a statement of OBD in-use Performance compliance.
Limit of validity of type approvals
As from the 1 January 2014, type approvals granted to this Regulation as amended by the 05 series of amendments shall cease to be valid.
As from 1 September 2015, type approvals granted to this Regulation as amended by the 06 series of amendments, which do not comply with the requirement of paragraph 13.2.1., shall cease to be valid.
As from 31 December 2016, type approvals granted to this Regulation as amended by the 06 series of amendments, which do not comply with the requirements of paragraph 13.2.2., shall cease to be valid.
Special provisions
Contracting Parties applying this Regulation may continue to grant approvals to those engine systems, or vehicles which comply with any previous series of amendments, or to any level of this Regulation provided that the vehicles are intended for sale or for export to countries that apply the relating requirements in their national legislations.
Replacement engines for vehicles in use
Contracting Parties applying this Regulation may continue to grant approvals to those engines which comply with the requirements of this Regulation as amended by any previous series of amendments, or to any level of this Regulation, provided that the engine is intended as a replacement for a vehicle in-use and for which that earlier standard was applicable at the date of that vehicle's entry into service.
When applying the special provisions described in paragraph 13.4.1. or paragraph 13.4.2., the type approval communication in paragraph 1.6. of the Addendum to Annexes 2A and 2C shall include information relating to these provisions.
In the case of approvals to the special provisions laid down in paragraph 13.4.1. the type approval communication shall include the following text at the front-end of the communication, with the relevant number of the series of amendments replacing the "xx" in the example below: "Engine complying to series of amendments xx of Regulation No. 49".
In the case of approvals to the special provisions laid down in paragraph 13.4.2. the type approval communication shall include the following text at the front-end of the communication, with the relevant number of the series of amendments replacing the "xx" in the example below: "Replacement engine complying to series of amendments xx of Regulation No. 49".
Names and addresses of Technical Services responsible for conducting approval tests and of Type Approval Authorities The Parties to the 1958 Agreement applying this Regulation shall communicate to the United Nations Secretariat the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, issued in other countries, are to be sent.
Appendix 1 — Procedure for production conformity testing when standard
deviation is satisfactory A.1.1. This appendix describes the procedure to be used to verify production conformity for the emissions of pollutants when the manufacturer's production standard deviation is satisfactory. A.1.2. With a minimum sample size of three engines the sampling procedure is set so that the probability of a lot passing a test with 40 per cent of the engines defective is 0.95 (producer's risk = 5 per cent) while the probability of a lot being accepted with 65 per cent of the engines defective is 0.10 (consumer's risk = 10 per cent). A.1.3. The following procedure is used for each of the pollutants given in paragraph 5.3. of this Regulation (see Figure 1 in paragraph 8.3. of this Regulation): Let: L = the natural logarithm of the limit value for the pollutant; xi = the natural logarithm of the measurement (after having applied the relevant DF) for the i-th engine of the sample; s = an estimate of the production standard deviation (after taking the natural logarithm of the measurements); n = the current sample number.
A.1.4. For each sample the sum of the standardized deviations to the limit is calculated using the following formula:
1 n (L xi) s i 1 A.1.5. Then:
(a) If the test statistic result is greater than the pass decision number for the sample size given in Table 2, a pass decision is reached for the pollutant;
(b) If the test statistic result is less than the fail decision number for the sample size given in Table 2, a fail decision is reached for the pollutant;
(c) Otherwise, an additional engine is tested according to paragraph 8.3.2. and the calculation procedure is applied to the sample increased by one more unit.
Appendix 1
Pass and fail decision numbers of Appendix 1 sampling plan
Minimum sample size: 3 Cumulative number of engines tested (sample size) Pass decision number An Fail decision number Bn 3 3.327 − 4.724 4 3.261 − 4.790 5 3.195 − 4.856 6 3.129 − 4.922 7 3.063 − 4.988 8 2.997 − 5.054 9 2.931 − 5.120 10 2.865 − 5.185 11 2.799 − 5.251 12 2.733 − 5.317 13 2.667 − 5.383 14 2.601 − 5.449 15 2.535 − 5.515 16 2.469 − 5.581 17 2.403 − 5.647 18 2.337 − 5.713 19 2.271 − 5.779 20 2.205 − 5.845 21 2.139 − 5.911 22 2.073 − 5.977 23 2.007 − 6.043 24 1.941 − 6.109 25 1.875 − 6.175 26 1.809 − 6.241 27 1.743 − 6.307 28 1.677 − 6.373 29 1.611 − 6.439 30 1.545 − 6.505 31 1.479 − 6.571 32 − 2.112 − 2.112
Appendix 2 — Procedure for production conformity testing when standard
deviation is unsatisfactory or unavailable A.2.1. This appendix describes the procedure to be used to verify production conformity for the emissions of pollutants when the manufacturer's production standard deviation is either unsatisfactory or unavailable. A.2.2. With a minimum sample size of three engines the sampling procedure is set so that the probability of a lot passing a test with 40 per cent of the engines defective is 0.95 (producer's risk = 5 per cent) while the probability of a lot being accepted with 65 per cent of the engines defective is 0.10 (consumer's risk = 10 per cent). A.2.3. The values of the pollutants given in paragraph 5.3. of this Regulation, after having applied the relevant DF, are considered to be log normally distributed and should be transformed by taking their natural logarithms. Let m 0 and m denote the minimum and maximum sample size respectively (m0 = 3 and m = 32) and let n denote the current sample number. A.2.4. If the natural logarithms of the measured values (after having applied the relevant DF) in the series are x1, x2, … xi and L is the natural logarithm of the limit value for the pollutant, then, define: di xi L
1 n dn di n i 1
1 n v 2n di d n n i1
A.2.5. Table 3 shows values of the pass (An) and fail (Bn) decision numbers against current sample number. The test statistic result is the ratio d n /v n and shall be used to determine whether the series has passed or failed as follows: For m0 ≤ n ≤ m:
(a) Pass the series if dn /vn An
(b) Fail the series if dn /vn Bn
(c) Take another measurement if An dn /vn Bn
A.2.6. Remarks The following recursive formulae are useful for calculating successive values of the test statistic:
1 1 d n 1 d n 1 d n n n
Appendix 2
1 v2n 1 v2n 1 d d n n
n n 1
n 2, 3,...; d 1 d 1; v 1 0
Pass and fail decision numbers of Appendix 2 sampling plan
Minimum sample size: 3 Cumulative number of engines tested (sample size) Pass decision number An Fail decision number Bn 3 − 0.80381 16.64743 4 − 0.76339 7.68627 5 − 0.72982 4.67136 6 − 0.69962 3.25573 7 − 0.67129 2.45431 8 − 0.64406 1.94369 9 − 0.61750 1.59105 10 − 0.59135 1.33295 11 − 0.56542 1.13566 12 − 0.53960 0.97970 13 − 0.51379 0.85307 14 − 0.48791 0.74801 15 − 0.46191 0.65928 16 − 0.43573 0.58321 17 − 0.40933 0.51718 18 − 0.38266 0.45922 19 − 0.35570 0.40788 20 − 0.32840 0.36203 21 − 0.30072 0.32078 22 − 0.27263 0.28343 23 − 0.24410 0.24943 24 − 0.21509 0.21831 25 − 0.18557 0.18970 26 − 0.15550 0.16328 27 − 0.12483 0.13880 28 − 0.09354 0.11603 29 − 0.06159 0.09480 30 − 0.02892 0.07493 31 − 0.00449 0.05629 32 0.03876 0.03876
Appendix 3
Procedure for production conformity testing at manufacturer's request A.3.1. This appendix describes the procedure to be used to verify, at the manufacturer's request, production conformity for the emissions of pollutants. A.3.2. With a minimum sample size of three engines the sampling procedure is set so that the probability of a lot passing a test with 30 per cent of the engines defective is 0.90 (producer's risk = 10 per cent) while the probability of a lot being accepted with 65 per cent of the engines defective is 0.10 (consumer's risk = 10 per cent). A.3.3. The following procedure is used for each of the pollutants given in paragraph 5.3. of this Regulation (see Figure 1 in paragraph 8.3. of this Regulation): Let: n = the current sample number. A.3.4. Determine for the sample the test statistic quantifying the cumulative number of nonconforming tests at the nth test. A.3.5. Then:
(a) If the test statistic is less than or equal to the pass decision number for the sample size given in Table 4, a pass decision is reached for the pollutant;
(b) If the test statistic is greater than or equal to the fail decision number for the sample size given in Table 4, a fail decision is reached for the pollutant;
(c) Otherwise, an additional engine is tested according to paragraph 8.3.2. of this Regulation and the calculation procedure is applied to the sample increased by one more unit. In Table 4 the pass and fail decision numbers are calculated by means of the International Standard ISO 8422/1991.
Appendix 3
Pass and fail decision numbers of Appendix 3 sampling plan
Minimum sample size: 3
Cumulative number of engines tested (sample size) Pass decision number Fail decision number
3 — 3
4 0 4
5 0 4
6 1 5
7 1 5
8 2 6
9 2 6
10 3 7
11 3 7
12 4 8
13 4 8
14 5 9
15 5 9
16 6 10
17 6 10
18 7 11
19 8 9
Appendix 4Appendix 4 — Summary of approval process for natural gas and LPG fuelled engines
Approval of LPG fuelled engines
Paragraph 4.7.: Requirements Paragraph 4.6.: on restricted fuel range type Number of Number of Calculation Requirements on universal Calculation of "r" approval in case of positive test runs test runs of "r" fuel range type approval ignition engines fuelled with natural gas or LPG
Refer to para. 4.6.6. fuel B LPG-engine adaptable to r Fuel A and fuel B 2 fuel any fuel composition A
Refer to para. 4.7.2. Fuel A and fuel B, LPG-engine laid out for operation on one specific fine-tuning between the tests fuel composition allowed Approval of natural gas fuelled engines
Paragraph 4.7.: Requirements on restricted fuel range type approval in case of Paragraph 4.6.: positive ignition engines Requirements on universal Number of fuelled with natural gas fuel range type approval test runs Calculation of "r" or LPG Number of test runs Calculation of "r" fuel 2(G25) r fuel 1 (GR)
GR (1) and G25 (2) and, if tested with an additional Refer to para. 4.6.3. 2 fuel; NG-engine At manufacturer’s request engine may be tested on an fuel 2(G25) adaptable to any ra fuel composition additional market fuel (3), (max. 3) fuel 3(market fuel) if S = 0.89 – 1.19 and fuel 1 (GR) rb fuel 3(G23 or market fuel) 2 for the GR (1) and G23 (3) for H fuel 1 (GR) H-range, and rb Refer to para. 4.6.4. and G25 (2) and G23 (3) for L 2 for the fuel 3(G23 or market fuel) NG-engine which At manufacturer’s request L-range; and is self-adaptive by a engine may be tested on a at respective fuel 2(G25) switch market fuel (3) instead of ra position of fuel 3(G23 or market fuel) G23, if S = 0.89 – 1.19 switch 4 GR (1) and G23 (3) for rb fuel 1 (GR)
H or 2 for the H-range fuel 3(G23 or market fuel) Refer to para. 4.7.1. NG-engine laid out G25 (2) and G23 (3) for L or for the H-range for operation on At manufacturer’s 2 for the L-range or either H-range gas request engine may be fuel 2(G25) or L-range gas tested on a market fuel ra
(3) instead of G23, if S 2 fuel 3(G23 or market fuel)
= 0.89 – 1.19 for the L-range GR (1) and G25 (2), Fine-tuning between the 2
Refer to para. 4.7.2. tests allowed; or NG-engine laid out At manufacturer’s request engine may be 2 for the H-range for operation on one specific fuel tested on: or composition GR (1) and G23 (3) for H 2 for the L-range or 2 G25 (2) and G23 (3) for L
Appendix 4
Annex 1 — Models of information document
This information document is related to the approval according to Regulation No. 49. It is referring to measures to be taken against the emission of gaseous and particulate pollutants from engine systems and vehicles. It relates to: Type approval of an engine or engine family as a separate technical unit, Type approval of vehicle with an approved engine with regard to emission, Type approval of a vehicle with regard to emissions. The following information, when applicable, shall be supplied in triplicate and include a list of contents. Any drawings shall be supplied in appropriate scale and in sufficient detail on size A4 or on a folder of A4 format. Photographs, if any, shall show sufficient detail. If the systems, components or separate technical units referred to in this annex have electronic controls, information concerning their performance shall be supplied.
Information to be provided
The information document shall contain in all cases: General Information In addition the following information should also be provided as applicable Part 1: Essential characteristics of the (parent) engine and the engine types within an engine family Part 2: Essential characteristics of the vehicle components and systems with regard to exhaust-emissions Appendix to information document: Information on test conditions Photographs and/or drawings of the parent engine, engine type and, if applicable, of the engine compartment. List further attachments if any. Date, file
Annex 1
Notes regarding filling in the tables Letters A, B, C, D, E corresponding to engine family members shall be replaced by the actual engine family members’ names. In case when for a certain engine characteristic same value/description applies for all engine family members the cells corresponding to A-E shall be merged. In case the family consists of more than 5 members, new columns may be added. In the case of application for type approval of an engine or engine family as a separate technical unit the general part and Part 1 shall be filled in. In the case of application for type approval of vehicle with an approved engine with regard to emissions the general part and Part 2 shall be filled in. In the case of application for type approval of a vehicle with regard to emissions the general part and Parts 1 and 2 shall be filled in.
Annex 1 Parent engine or Engine family members engine type A B C D E
0.General
0.l. Make (trade name of manufacturer)
Type
Engine type as separate technical unit / engine family as separate technical unit / vehicle with an approved engine with regard to emissions / vehicle with regard to emissions1
Commercial name(s) (if available)
Means of identification of type, if marked on the separate technical unit2
Location of that marking
Name and address of manufacturer
In the case of components and separate technical units, location and method of affixing of the approval mark
Name(s) and address (es) of assembly plant(s)
Name and address of the manufacturer’s representative (if any) Part 1
Essential characteristics of the (parent) engine and the engine types within an engine family
Parent engine or engine type Engine family members
A B C D E
Internal combustion engine
Specific engine information
Working principle: positive ignition/compression ignition1
Cycle four stroke / two stroke/ rotary1
Number and arrangement of cylinders
Bore3 mm
Stroke3 mm
Firing order
Engine capacity4 cm³
Volumetric compression ratio5
Drawings of combustion chamber, piston crown and, in the case of positive ignition engines, piston rings
Normal engine idling speed5 min-1
High engine idling speed5 min-1
Carbon monoxide content by volume in the exhaust gas with
the engine idling5: % as stated by the manufacturer (positive ignition engines only)
Maximum net power6………….. kW at…….min-1
(manufacturer's declared value)
Maximum permitted engine speed as prescribed by the manufacturer (min-1)
Maximum net torque6 (Nm) at (min-1) (manufacturer's declared value)
Annex 1
Annex 1 Parent engine or engine type Engine family members
A B C D E
Manufacturer references of the documentation package required by paragraphs 3.1., 3.2. and 3.3. of this Regulation enabling the Type Approval Authority to evaluate the emission control strategies and the systems on-board the engine to ensure the correct operation of NOx control measures
Fuel
Heavy duty vehicles Diesel/Petrol/LPG/NG-H/NG-L/NG-
HL/Ethanol (ED95)/ Ethanol (E85)1
Fuels compatible with use by the engine declared by the manufacturer in accordance with paragraph 4.6.2. of this Regulation (as applicable)
Fuel feed
By fuel injection (compression ignition only): Yes/No1
System description
Working principle: direct injection/pre-chamber/swirl chamber1
Injection pump
Make(s)
Type(s)
Maximum fuel delivery1,5 …... mm3 /stroke or cycle at an engine speed of …… min-1 or, alternatively, a characteristic diagram (When boost control is supplied, state the characteristic fuel delivery and boost pressure versus engine speed)
Static injection timing5
Injection advance curve5
Calibration procedure: test bench/engine1
Parent engine or engine type Engine family members
A B C D E
Governor
Type
Cut-off point
Speed at which cut-off starts under load (min-1)
Maximum no-load speed (min-1)
Idling speed (min-1)
Injection piping
Length (mm)
Internal diameter (mm)
Common rail, make and type
Injector(s)
Make(s)
Type(s)
Opening pressure5: kPa or characteristic diagram5
Cold start system
Make(s)
Type(s)
Description
Auxiliary starting aid
Make(s)
Type(s)
System description
Electronic controlled injection: Yes/No1
Make(s)
Annex 1
Type(s)
Annex 1 Parent engine or engine type Engine family members
A B C D E
Description of the system (in the case of systems other than continuous injection give equivalent details)
Make and type of the control unit (ECU)
Make and type of the fuel regulator
Make and type of the air-flow sensor
Make and type of fuel distributor
Make and type of the throttle housing
Make and type of water temperature sensor
Make and type of air temperature sensor
Make and type of air pressure sensor
Software calibration number(s)
By fuel injection (positive ignition only): Yes/No1
Working principle: intake manifold (single-/multi-point/direct injection1/other specify)
Make(s)
Type(s)
System description (In the case of systems other than continuous injection give equivalent details)
Make and type of the control unit (ECU)
Make and type of fuel regulator
Make and type of air-flow sensor
Make and type of fuel distributor
Make and type of pressure regulator
Make and type of micro switch
Make and type of idling adjustment screw
Make and type of throttle housing
Parent engine or engine type Engine family members
A B C D E
Make and type of water temperature sensor
Make and type of air temperature sensor
Make and type of air pressure sensor
Software calibration number(s)
Injectors: opening pressure5 (kPa) or characteristic diagram5
Make
Type
Injection timing
Cold start system
Operating principle(s)
Operating limits/settings1,5
Feed pump
Pressure5 (kPa) or characteristic diagram5
Electrical system
Rated voltage (V), positive/negative ground (1)
Generator
Type
Nominal output (VA)
Ignition system (spark ignition engines only)
Make(s)
Type(s)
Working principle
Ignition advance curve or map5
Static ignition timing5 (degrees before TDC)
Annex 1
Spark plugs
Annex 1 Parent engine or engine type Engine family members
A B C D E
Make
Type
Gap setting (mm)
Ignition coil(s)
Make
Type
Cooling system: liquid/air1
Liquid
Nature of liquid
Circulating pump(s): Yes/No1
Characteristics
Make(s)
Type(s)
Drive ratio(s)
Air
Fan: Yes/No1
Characteristics
Make(s)
Type(s)
Drive ratio(s)
Intake system
Pressure charger: Yes/No 1
Make(s)
Type(s)
Parent engine or engine type Engine family members
A B C D E
Description of the system (e.g. maximum charge pressure …... kPa, wastegate, if applicable)
Intercooler: Yes/No1
Type: air-air/air-water1
Intake depression at rated engine speed and at 100 % load (compression ignition engines only)
Minimum allowable (kPa)
Maximum allowable (kPa)
Description and drawings of inlet pipes and their accessories (plenum chamber, heating device, additional air intakes, etc.)
Intake manifold description (include drawings and/or photos)
Exhaust system
Description and/or drawings of the exhaust manifold
Description and/or drawing of the exhaust system
Description and/or drawing of the elements of the exhaust system that are part of the engine system
Maximum allowable exhaust back pressure at rated engine speed and at 100 % load (compression ignition engines only)(kPa)7
Exhaust system volume (dm³)
Acceptable Exhaust system volume: (dm³)
Minimum cross-sectional areas of inlet and outlet ports
Valve timing or equivalent data
Maximum lift of valves, angles of opening and closing, or timing details of alternative distribution systems, in relation to dead centers. For variable timing system, minimum and
Annex 1 maximum timing
Annex 1 Parent engine or engine type Engine family members
A B C D E
Reference and/or setting range
Measures taken against air pollution
Device for recycling crankcase gases: Yes/No 1
If yes, description and drawings If no, compliance with paragraph 6.10. of Annex 4 of this Regulation required
Additional pollution control devices (if any, and if not covered by another heading)
Catalytic converter: Yes/No1
Number of catalytic converters and elements (provide this information below for each separate unit)
Dimensions, shape and volume of the catalytic converter(s)
Type of catalytic action
Total charge of precious metals
Relative concentration
Substrate (structure and material)
Cell density
Type of casing for the catalytic converter(s)
Location of the catalytic converter(s) (place and reference distance in the exhaust line)
Heat shield: Yes/No1
Regeneration systems/method of exhaust after treatment systems, description
Normal operating temperature range (K)
Consumable reagents: Yes/No1
Parent engine or engine type Engine family members
A B C D E
Type and concentration of reagent needed for catalytic action
Normal operational temperature range of reagent K
International standard
Frequency of reagent refill: continuous/maintenance1
Make of catalytic converter
Identifying part number
Oxygen sensor: Yes/No1
Make
Location
Control range
Type
Indentifying part number
Air injection: Yes/No1
Type (pulse air, air pump, etc.)
Exhaust gas recirculation (EGR): Yes/No1
Characteristics (make, type, flow, etc)
Particulate trap (PT): Yes/No1
Dimensions, shape and capacity of the particulate trap
Design of the particulate trap
Location (reference distance in the exhaust line)
Method or system of regeneration, description and/or drawing
Make of particulate trap
Indentifying part number
Normal operating temperature (K) and pressure (kPa) ranges
Annex 1
In the case of periodic regeneration
Annex 1 Parent engine or engine type Engine family members
A B C D E
3.2.12.2.6.8.1.1. Number of WHTC test cycles without regeneration (n)
3.2.12.2.6.8.2.1. Number of WHTC test cycles with regeneration (nR)
Other systems: Yes/No1
Description and operation
On-board-diagnostic (OBD) system
Number of OBD engine families within the engine family
List of the OBD engine families (when applicable) OBD engine family 1: …………. OBD engine family 2: …………. etc…
Number of the OBD engine family the parent engine / the engine member belongs to
Manufacturer references of the OBD-Documentation required by paragraph 3.1.4. (c) and paragraph 3.3.4. of this Regulation and specified in Annex 9A of this Regulation for the purpose of approving the OBD system When appropriate, manufacturer reference of the Documentation for installing in a vehicle an OBD equipped
engine system
List and purpose of all components monitored by the OBD
system8
Written description (general working principles) for
Positive-ignition engines8
3.2.12.2.7.3.1.1. Catalyst monitoring8 3.2.12.2.7.3.1.2. Misfire detection8 Parent engine or engine type Engine family members
A B C D E 3.2.12.2.7.3.1.3. Oxygen sensor monitoring 3.2.12.2.7.3.1.4. Other components monitored by the OBD system
Compression-ignition engines8
3.2.12.2.7.3.2.1. Catalyst monitoring8 3.2.12.2.7.3.2.2. Particulate trap monitoring8 3.2.12.2.7.3.2.3. Electronic fuelling system monitoring8 3.2.12.2.7.3.2.4. DeNOx system monitoring8 3.2.12.2.7.3.2.5. Other components monitored by the OBD system8 Criteria for MI activation (fixed number of driving cycles or
statistical method) 8
List of all OBD output codes and formats used (with
explanation of each) 8
OBD Communication protocol standard8
Manufacturer reference of the OBD related information required by of paragraphs 3.1.4. (d) and 3.3.4. this Regulation for the purpose of complying with the provisions on access to vehicle OBD, or
As an alternative to a manufacturer reference provided in
paragraph 3.2.12.2.7.7. reference of the attachment to this annex that contains the following table, once completed according to the given example:
Component - Fault code - Monitoring strategy - Fault detection criteria - MI activation criteria - Secondary parameters – Preconditioning - Demonstration test SCR Catalyst - P20EE - NOx sensor 1 and 2 signals - Difference between sensor 1 and sensor 2 signals - 2nd cycle - Engine speed, engine load, catalyst temperature, reagent activity, exhaust mass flow - One OBD test cycle (WHTC, hot
Annex 1
part) - OBD test cycle (WHTC, hot part)
Annex 1 Parent engine or engine type Engine family members
A B C D E
Other system (description and operation)
Systems to ensure the correct operation of NOx control measures
Engine with permanent deactivation of the driver inducement, for use by the rescue services or in vehicles designed and constructed for use by the armed services, civil defence, fire services and forces responsible for maintaining public order: Yes/No1
Number of OBD engine families within the engine family considered when ensuring the correct operation of NOx control measures
List of the OBD engine families (when applicable) OBD engine family 1: …………. OBD engine family 2: …………. etc…
Number of the OBD engine family the parent engine / the engine member belongs to
Lowest concentration of the active ingredient present in the reagent that does not activate the warning system (CD min) (% vol)
When appropriate, manufacturer reference of the Documentation for installing in a vehicle the systems to ensure the correct operation of NOx control measures
Specific information related to gas fuelled engines for heavy- duty vehicles (in the case of systems laid out in a different manner, supply equivalent information)
Fuel: LPG /NG-H/NG-L /NG-HL1
Pressure regulator(s) or vaporiser/pressure regulator(s) 1
Make(s)
Type(s)
Parent engine or engine type Engine family members
A B C D E
Number of pressure reduction stages
Pressure in final stage minimum (kPa) – maximum. (kPa)
Number of main adjustment points
Number of idle adjustment points
Type approval number
Fuelling system: mixing unit / gas injection / liquid injection / direct injection1
Mixture strength regulation
System description and/or diagram and drawings
Type approval number
Mixing unit
Number
Make(s)
Type(s)
Location
Adjustment possibilities
Type approval number
Inlet manifold injection
Injection: single point/multipoint1
Injection: continuous/simultaneously timed/sequentially timed 1
Injection equipment
Make(s)
Type(s)
Adjustment possibilities
Type approval number
Annex 1
Supply pump (if applicable)
Annex 1 Parent engine or engine type Engine family members
A B C D E
Make(s)
Type(s)
Type approval number
Injector(s)
Make(s)
Type(s)
Type approval number
Direct injection
Injection pump/pressure regulator1
Make(s)
Type(s)
Injection timing
Type approval number
Injector(s)
Make(s)
Type(s)
Opening pressure or characteristic diagram1
Type approval number
Electronic control unit (ECU)
Make(s)
Type(s)
Adjustment possibilities
Software calibration number(s)
NG fuel-specific equipment
Variant 1 (only in the case of approvals of engines for several specific fuel compositions) Parent engine or engine type Engine family members
A B C D E
Self-adaptive feature? Yes/No1
Calibration for a specific gas composition NG-H/NG-L/NG-
HL1 Transformation for a specific gas composition NG-Ht/NG- Lt/NG-HLt 1
CO2 emissions for heavy duty engines
CO2 mass emissions WHSC test (g/kWh)
CO2 mass emissions WHTC test (g/kWh)
Fuel consumption for heavy duty engines
Fuel consumption WHSC test (g/kWh)
Fuel consumption WHTC test9 (g/kWh)
Temperatures permitted by the manufacturer
Cooling system
Liquid cooling Maximum temperature at outlet (K)
Air cooling
Reference point
Maximum temperature at reference point (K)
Maximum outlet temperature of the inlet intercooler (K)
Annex 1
Annex 1 Parent engine or engine type Engine family members
A B C D E
Maximum exhaust temperature at the point in the exhaust pipe(s) adjacent to the outer flange(s) of the exhaust manifold(s) or turbocharger(s) (K)
Fuel temperature Minimum (K) – maximum (K)
For diesel engines at injection pump inlet, for gas fuelled engines at pressure regulator final stage
Lubricant temperature
Minimum (K) – maximum (K)
Lubrication system
Description of the system
Position of lubricant reservoir
Feed system (by pump/injection into intake/mixing with fuel, etc.)1
Lubricating pump
Make(s)
Type(s)
Mixture with fuel
Percentage
Oil cooler: Yes/No1
Drawing(s)
Make(s)
Type(s)
Part 2 Essential characteristics of the vehicle components and systems with regard to exhaust-emissions
Parent engine or engine type Engine family members A B C D E
Manufacturer of the engine
Manufacturer’s engine code (as marked on the engine or other means of identification)
Approval number (if appropriate) including fuel identification marking
Fuel
Fuel tank inlet: restricted orifice / label
Fuel tank(s)
Service fuel tank(s)
Number and capacity of each tank
Reserve fuel tank(s)
Number and capacity of each tank
Intake system
Actual Intake system depression at rated engine speed and at
100 % load on the vehicle (kPa)
Air filter, drawings
Make(s)
Type(s)
Intake silencer, drawings
Make(s)
Type(s)
Annex 1
Exhaust system
Annex 1 Parent engine or engine type Engine family members A B C D E
Description and/or drawing of the exhaust system
Description and/or drawing of the elements of the exhaust system that are not part of the engine system
Actual exhaust back pressure at rated engine speed and at 100 % load on the vehicle (compression ignition engines only) (kPa)
Exhaust system volume (dm³)
Actual volume of the complete Exhaust system (vehicle and engine system) (dm³)
On-board-diagnostic (OBD) system
Alternative approval as defined in paragraph 2.4. of Annex 9A of this Regulation used: Yes/No1
OBD components on-board the vehicle
When appropriate, manufacturer reference of the documentation package related to the installation on the vehicle of the OBD system of an approved engine
Written description and/or drawing of the MI 10
Written description and/or drawing of the OBD off-board communication interface10
Systems to ensure the correct operation of NOx control measures
Alternative approval as defined in paragraph 2.1. of Annex 1111 of this Regulation used. Yes/No1
Components on-board the vehicle of the systems ensuring the correct operation of NOx control measures
Activation of the creep mode: "disable after restart" / "disable after fuelling" / "disable after parking"12 Parent engine or engine type Engine family members A B C D E
When appropriate, manufacturer reference of the documentation package related to the installation on the vehicle of the system ensuring the correct operation of NOx control measures of an approved engine
Written description and/or drawing of the warning signal 10
Heated/non heated reagent tank and dosing system (see paragraph 2.4. of Annex 11 of this Regulation)
Notes: Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable). If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered by this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC?123??). This figure shall be rounded off to the nearest tenth of a millimetre. This value shall be calculated and rounded off to the nearest cm3. Specify the tolerance. Determined in accordance with the requirements of Regulation No. 85. Please fill in here the upper and lower values for each variant. To be documented in case of a single OBD engine family and if not already documented in the documentation package(s) referred to in line 3.2.12.2.7.0.4. of Part 1 to Annex 1. Fuel consumption for the combined WHTC including cold and hot part according to Annex 12. To be documented if not already in the documentation referred to in line 3.2.12.2.7.2. of Part 2 to Annex 1. Paragraph 2.1. of Annex 11 has been reserved for future alternative approvals. Delete as appropriate.
Annex 1 Annex 1 – Appendix
Appendix to information document Information on test conditions
1.Spark plugs
Make
Type
Spark-gap setting
2.Ignition coil
Make
Type
3.Lubricant used
Make
Type (state percentage of oil in mixture if lubricant and fuel mixed)
4.Engine-driven equipment
The power absorbed by the auxiliaries/equipment needs only be determined,
(a) If auxiliaries/equipment required are not fitted to the engine and/or
(b) If auxiliaries/equipment not required are fitted to the engine. Note: Requirements for engine-driven equipment differ between emissions test and power test
Enumeration and identifying details
Power absorbed at engine speeds specific for emissions test
Power absorbed at engine speeds specific for emissions test
Equipment Idle Low speed High speed Preferred speed2 n95h Pa Auxiliaries/equipment required according to Annex 4, Appendix 6 Pb Auxiliaries/equipment not required according to Annex 4, Appendix 6
5.Engine performance (declared by manufacturer)1
Engine test speeds for emissions test according to annex 42
Low speed (nlo) ………………………….. rpm
Information concerning engine performance shall only be given for the parent engine. Specify the tolerance; to be within ±3 % of the values declared by the manufacturer.
Annex 1 – Appendix
High speed (nhi) ………………………….. rpm Idle speed ………………………….. rpm Preferred speed ………………………….. rpm n95h ………………………….. rpm
Declared values for power test according to Regulation No. 85
Idle speed ………………………….. rpm
Speed at maximum power ………………………….. rpm
Maximum power ………………………….. kW
Speed at maximum torque ………………………….. rpm
Maximum torque ………………………….. Nm
6.Dynamometer load setting information (if applicable)
Reserved for Vehicle body work type (not applicable)
Reserved for gearbox type (not applicable)
Fixed load curve dynamometer setting information (if used)
Alternative dynamometer load setting method used (Yes/No3)
Inertia mass (kg)
Effective power absorbed at 80km/h including running losses of the vehicle on the dynamometer (kW)
Effective power absorbed at 50km/h h including running losses of the vehicle on the dynamometer (kW)
Adjustable load curve dynamometer setting information (if used)
Coast down information from the test track
Tyres make and type
Tyre dimensions (front/rear)
Tyre pressure (front/rear) (kPa)
Vehicle test mass including driver (kg)
Road coast down data (if used)
Road coast down data
Mean corrected coast V (km/h) V2 (km/h) V1 (km/h) down time Delete as appropriate. Annex 1 – Appendix
Average corrected road power (if used)
Average corrected road power
V (km/h) CP corrected (kW)
7.Test conditions for OBD testing
Test cycle used for the verification of the OBD system
Number of preconditioning cycles used before OBD verification tests
Annex 2A
Annex 2A
Communication concerning the approval of an engine type or family as a separate technical unit with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration
Concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued
of an engine type or family as a separate technical unit with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments Reason for Extension ……………………
Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). Strike out what does not apply.
Annex 2A
Section I
Make (trade name of manufacturer)
Type
Commercial name(s) (if available)
Means of identification of type, if marked on the separate technical unit3
Location of that marking
Name and address of manufacturer
Location and method of affixing of the approval mark
Name(s) and address(es) of assembly plant(s)
Name and address of the manufacturer's representative (if any)
Section II
1.Additional information (where applicable): see Addendum
2.Technical Service responsible for carrying out the tests
3.Date of test report
4.Number of test report
5.Remarks (if any): see Addendum
6.Place
7.Date
8.Signature
Attachments: Information package. Test report.
If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered by this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC?123??).
Annex 2A – Addendum
Addendum to type approval communication No … concerning the type approval of an engine type or family as a separate technical unit with regard to exhaust emissions pursuant to Regulation No. 49, 06 series of amendments
1.Additional information
Particulars to be completed in relation to the type approval of a vehicle with an engine installed
Make of engine (name of undertaking)
Type and commercial description (mention any variants)
Manufacturer's code as marked on the engine
Reserved.
Category of engine: Diesel/Petrol/LPG/NG-H/NG-L/NG-HL/Ethanol (ED95)/ Ethanol (E85)1
Name and address of manufacturer
Name and address of manufacturer's authorised representative (if any)
Engine referred to in 1.1. type-approved as a separate technical unit
Type approval number of the engine/engine family1
Engine Control Unit (ECU) software calibration number
Particulars to be completed in relation to the type approval of an engine/engine family1 as a separate technical unit (conditions to be respected in the installation of the engine on a vehicle)
Maximum and/or minimum intake depression
Maximum allowable back pressure
Exhaust system volume
Restrictions of use (if any)
Emission levels of the engine/parent engine1
Deterioration Factor (DF): calculated/fixed1 Specify the DF values and the emissions on the WHSC (if applicable) and WHTC tests in the table below If CNG and LPG fuelled engines are tested on different reference fuels, the tables shall be reproduced for each reference fuel tested.
Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable).
Annex 2A – Addendum
WHSC test
WHSC test
WHSC test (if applicable)
DF CO THC NOX PM Mass NH3 PM
Mult/add(1) Number
Emissions CO THC NOX PM Mass NH3 PM
(mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) ppm Number
(#/kWh)
Test result
Calculated
with DF
CO2 emissions (mass emission, g/kWh)
Fuel consumption (g/kWh)WHTC Test
WHTC Test
WHTC test
DF CO THC NOx PM Mass NH3 PM
Mult/add1 Number
Emissions CO THC NOx PM Mass NH3 PM
(mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) ppm Number
Cold start
Hot start w/o
regeneration
Hot start with
regeneration1
kr,u (mult/add)1
kr,d (mult/add)1
Weighted test
result
Final test
result with DF
CO2 emissions (mass emission, g/kWh)
Fuel consumption (g/kWh)
Annex 2A – AddendumIdle test
Idle test
Test CO value Lambda1 Engine speed Engine oil
(%vol) (min-1) temperature (°C)
Low idle test N/A
High idle testPEMS demonstration test
PEMS demonstration test
Vehicle type (e.g. M3, N3 and application e.g. rigid or articulated truck, city bus) Vehicle description (e.g. vehicle model, prototype) Pass Fail Results2: CO THC NMHC CH4 NOx PM mass Work window conformity factor CO2 mass window conformity factor Trip information: Urban Rural Motorway Shares of time of the trip characterised by urban, rural and motorway operation as described in paragraph 4.5. of Annex 8 Shares of time of the trip characterised by accelerating, decelerating, cruising and stop as described in paragraph 4.5.5. of
Annex 8 — Minimum Maximum
Work window average power (%) CO2 mass window duration (s) Work window: percentage of valid windows CO2 mass window: percentage of valid windows Fuel consumption consistency ratio
Delete as appropriate.
Annex 2A – Addendum
Power measurement
Engine power measured on test bench
Engine power measured on test bench
Measured engine speed (rpm) Measured fuel flow (g/h) Measured torque (Nm) Measured power (kW) Barometric pressure (kPa) Water vapour pressure (kPa) Intake air temperature (K) Power correction factor Corrected power (kW) Auxiliary power (kW)1 Net power (kW) Net torque (Nm) Corrected specific fuel consumption (g/kWh)
Additional data
Special provisions
Granting approvals for vehicles for export (see paragraph 13.4.1. of this Regulation)
Approvals granted for vehicles for export in line with paragraph 1.6.1.: Yes/No2
Provide a description of approvals granted in paragraph 1.6.1.1., including the series of amendments of this Regualtion and the level of emission requirements to which this approval applies
Replacement engines for vehicles in use (see paragraph 13.4.2. of this Regulation)
Approvals granted for replacement engines for vehicles in use in line with paragraph 1.6.2.: Yes/No2
Provide a description of approvals for replacement engines for vehicles in use granted in paragraph 1.6.2.1. including the series of amendments of this Regualtion and the level of emission requirements to which this approval applies
Alternative approvals (see Annex 9A, paragraph 2.4.)
Alternative approvals granted in line with paragraph 1.7.: Yes/No2
Provide a description of alternative approvals in line with paragraph 1.7.1.
Annex 2B
Annex 2B
Communication concerning the approval of a vehicle type with an approved engine with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration
Concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a vehicle type with an approved engine with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments
Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). Strike out what does not apply.
Annex 2B
Section I
Make (trade name of manufacturer)
Type
Means of identification of type, if marked on the vehicle 3
Location of that marking
Category of vehicle4
Name and address of manufacturer
Name(s) and address(es) of assembly plant(s)
Name and address of the manufacturer's representative (if any) Section II
1.Additional information (where applicable)
2.Technical Service responsible for carrying out the tests
3.Date of test report
4.Number of test report
Remarks (if any)
6.Place
7.Date
8.Signature
In the case of an extension to the type approval of a vehicle with a reference mass exceeding 2,380 kg but not exceeding 2,610 kg, the reporting of the CO 2 emissions (g/km) and fuel consumption (l/100 km) shall be included in accordance with Annex 8 of Regulation No. 101.
If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered by this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC?123??). Classified according to definitions listed in "Consolidated Resolution on the Construction of Vehicles (R.E.3)" - ECE/TRANS/WP.29/78/Rev.2, para.2.
Annex 2C
Annex 2C
Communication concerning the approval of a vehicle type with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration
Concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued
of a vehicle type with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments
Reason for Extension ……………………
Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). Strike out what does not apply.
Annex 2C
Section I
Make (trade name of manufacturer)
Type
Commercial name(s) (if available)
Means of identification of type, if marked on the vehicle 3
Location of that marking
Category of vehicle4
Name and address of manufacturer
Name(s) and address(es) of assembly plant(s)
Name and address of the manufacturer's representative (if any)
Section II
1.Additional information (where applicable): see Addendum
2.Technical Service responsible for carrying out the tests
3.Date of test report
4.Number of test report
5.Remarks (if any): see Addendum
6.Place
7.Date
8.Signature
Attachments: Information package. Test report. Addendum In the case of an extension to the type approval of a vehicle with a reference mass exceeding 2,380 kg but not exceeding 2,610 kg, the reporting of the CO 2 emissions (g/km) and fuel consumption (l/100 km) shall be included in accordance with Annex 8 of Regulation No. 101.
If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered by this information document, such characters shall be represented in the documentation by the symbol "?" (e.g. ABC?123??). Classified according to definitions listed in "Consolidated Resolution on the Construction of Vehicles (R.E.3)" - ECE/TRANS/WP.29/78/Rev.2, para.2.
Annex 2C – Addendum
Addendum to type approval communication No … concerning the type approval of a vehicle type with regard to the emission of pollutants pursuant to Regulation No. 49, 06 series of amendments
1.Additional information
Particulars to be completed in relation to the type approval of a vehicle with an engine installed
Make of engine (name of undertaking)
Type and commercial description (mention any variants)
Manufacturer's code as marked on the engine
Category of vehicle
Category of engine: Diesel/Petrol/LPG/NG-H/NG-L/NG-HL/Ethanol (ED95)/ Ethanol (E85)1
Name and address of manufacturer
Name and address of manufacturer's authorised representative (if any)
Vehicle
Type approval number of the engine/engine family1
Engine Control Unit (ECU) software calibration number
Particulars to be completed in relation to the type approval of an engine/engine family1 (conditions to be respected in the installation of the engine on a vehicle)
Maximum and/or minimum intake depression
Maximum allowable back pressure
Exhaust system volume
Restrictions of use (if any)
Emission levels of the engine/parent engine1
Deterioration Factor (DF): calculated/fixed1 Specify the DF values and the emissions on the WHSC (if applicable) and WHTC tests in the table below If CNG and LPG fuelled engines are tested on different reference fuels, the tables shall be reproduced for each reference fuel tested.
Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable).
Annex 2C – Addendum
WHSC test
WHSC test
WHSC test (if applicable)
DF CO THC NOX PM Mass NH3 PM
Mult/add1 Number
Emissions CO THC NOx PM Mass NH3 PM
(mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) ppm Number
(#/kWh)
Test result
Calculated
with DF
CO2 emissions (mass emission, g/kWh)
Fuel consumption (g/kWh)WHTC Test
WHTC Test
WHTC test
DF CO THC NOX PM Mass NH3 PM
Mult/add1 Number
Emissions CO THC NOx PM Mass NH3 PM
(mg/kWh) (mg/kWh) (mg/kWh) (mg/kWh) ppm Number
Cold start
Hot start w/o
regeneration
Hot start with
regeneration1
kr,u (mult/add)1
kr,d (mult/add)1
Weighted test
result
Final test
result with DF
CO2 emissions (mass emission, g/kWh)
Fuel consumption (g/kWh)
Annex 2C – AddendumIdle test
Idle test
Test CO value Lambda1 Engine speed Engine oil
(%vol) (min-1) temperature (°C)
Low idle test N/A
High idle testPEMS demonstration test
PEMS demonstration test
Vehicle type (e.g. M3, N3 and application
e.g. rigid or articulated truck, city bus)
Vehicle description (e.g. vehicle model,
prototype)
Pass Fail Results2: CO THC NMHC CH4 NOx PM
mass
Work window conformity factor
CO2 mass window conformity factor
Trip information: Urban Rural Motorway
Shares of time of the trip characterised
by urban, rural and motorway operation
as described in paragraph 4.5. of
Shares of time of the trip characterised
by accelerating, decelerating, cruising
and stop as described in
paragraph 4.5.5. of Annex 8
Minimum Maximum
Work window average power (%)
CO2 mass window duration (s)
Work window: percentage of valid
windows
CO2 mass window: percentage of valid
windows
Fuel consumption consistency ratio
Delete as appropriate.
Annex 2C – Addendum
1.5 Power measurementEngine power measured on test bench
Engine power measured on test bench
Measured engine speed (rpm)
Measured fuel flow (g/h) Measured torque (Nm) Measured power (kW) Barometric pressure (kPa) Water vapour pressure (kPa) Intake air temperature (K) Power correction factor Corrected power (kW) Auxiliary power (kW)1 Net power (kW) Net torque (Nm) Corrected specific fuel consumption (g/kWh)
Additional data
Special provisions
Granting approvals for vehicles for export (see paragraph 13.4.1. of this Regulation)
Approvals granted for vehicles for export in line with paragraph 1.6.1.: Yes/No2
Provide a description of approvals granted in paragraph 1.6.1.1., including the series of amendments of this Regualtion and the level of emission requirements to which this approval applies
Alternative approvals (see Annex 9A, paragraph 2.4.)
Alternative approvals granted in line with paragraph 1.7.: Yes/No2
Provide a description of alternative approvals in line with paragraph 1.7.1.
Annex 3
Annex 3 — Arrangements of approval marks
In the approval mark issued and affixed to an engine system or vehicle in conformity with paragraph 4. of this Regulation, the type approval number shall be accompanied by an alphabetical character assigned according to Table 1 of this annex, reflecting the stage of requirements that the approval is limited to. In addition, the approval mark should also contain a character/s denoting the engine type, assigned according to Table 2 of this annex. This annex outlines the appearance of this mark, and gives examples of how it shall be composed. The following schematic presents the general lay-out, proportions and contents of the marking. The meaning of numbers and alphabetical character are identified, and sources to determine the corresponding alternatives for each approval case are also referred. Number of country1 Letter (s) denoting the granting the approval engine type2 Stage of requirements3 a 3 HLt a a E5 a 3 49 R – 062439 - A a a = 8 mm (minimum) Approval number Number of Regulation (Regulation No. 49) Amendment
Number of country according to footnote in paragraph 4.12.3.1. of this Regulation. According to Table 2 of this annex. According to Table 1 of this annex.
Example 1 Compressed-ignition engine fuelled with diesel (B7)
D E5 49 R – 062439 - C The preceding approval mark affixed to an engine or vehicle in conformity with paragraph 4. of this Regulation shows that the engine or vehicle type concerned has been approved in Sweden (E5), pursuant to Regulation No. 49, 06 series of amendments under approval number 2439. The letter after the approval number denotes the stage of requirements detailed in Table 1 (in this case Stage A). In addition, a separate suffix after the national symbol (and above the Regulation number) indicates the engine type as assigned in Table 2 (in this case "D" for diesel).
Example 2 Compressed-ignition engine fuelled with ethanol (ED95)
ED E5 49 R – 062439 - C The preceding approval mark affixed to an engine or vehicle in conformity with paragraph 4. of this Regulation shows that the engine or vehicle type concerned has been approved in Sweden (E5), pursuant to Regulation No. 49, 06 series of amendments under approval number 2439. The letter after the approval number denotes the stage of requirements detailed in Table 1 (in this case Stage B). In addition, a separate suffix after the national symbol (and above the Regulation number) indicates the engine type as assigned in Table 2 (in this case "ED" for ethanol (ED95)).
Example 3 Positive ignition engine fuelled with natural gas
HLt E5 49 R – 062439 - C
The preceding approval mark affixed to an engine or vehicle in conformity with paragraph 4. of this Regulation shows that the engine or vehicle type concerned has been approved in Sweden (E5), pursuant to Regulation No. 49, 06 series of amendments under approval number 2439. The letter after the approval number denotes the stage of requirements detailed in Table 1 (in this case Stage C). In addition, a separate suffix after the national symbol (and above the Regulation number) indicates the fuel range determined in paragraph 4.12.3.3.6. of this Regulation (in this case HLt).
Example 4 Positive ignition engine fuelled with LPG
Q E5 49 R – 062439 - C The preceding approval mark affixed to an engine or vehicle in conformity with paragraph 4. of this Regulation shows that the engine or vehicle type concerned has been approved in Sweden (E5), pursuant to Regulation No. 49, 06 series of amendments under approval number 2439. The letter after the approval number denotes the stage of requirements detailed in Table 1 (in this case Stage C). In addition, a separate suffix after the national symbol (and above the Regulation number) indicates the engine type as assigned in Table 2 (in this case "Q" for LPG).
Annex 3 Example 5
E5 49 HL 062439 - C a a a 3 2 a 85 001628 a a
The preceding approval mark affixed to a HL natural gas engine/vehicle shows that the engine/vehicle type concerned has been approved in Sweden (E5) pursuant to Regulation No. 49 (in this case Stage C) and Regulation No. 851. The first two digits of the approval numbers indicate that, at the dates when the respective approvals were given, Regulation No. 49 included the 06 series of amendments, and Regulation No. 85 in its original form.
Letters with reference to requirements of OBD and SCR systems
Character Reagent quality Date when type
Additional Implementation
NOx OTL1 PM OTL2 and approval cease to
OBD monitors3 dates: new types
consumption be valid
A4 Row "phase-in Date of entry into 1 September 2014
Performance.
period" of Tables 1 Phase in6 N/A force of 06 series
monitoring5
and 2 of Annex 9A of R49
B4 Row "phase- 1 September 2014 31 December 2016
Row "phase-in
in period" of 6
period" of Tables 1 Phase in N/A
and 2 of Annex 9A
Annex 9A
C Row "general Row "general 31 December 2015
requirements" of requirements" 7
General Yes
Tables 1 and 2 of of Table 1 of
Annex 9A Annex 9A
Notes:
"NOx OTL" monitoring requirements as set out in Tables 1 and 2 of Annex 9A.
"PM OTL" monitoring requirements as set out in Table 1 of Annex 9A.
The requirements regarding the plan and implementation of the monitoring techniques according to paragraphs 2.3.1.2. andof Annex 9A. During the phase-in period set out in paragraph 4.10.7. of this Regulation, the manufacturer shall be exempted from providing the statement required by paragraph 6.4.1. of Annex 9A. "Performance monitoring" requirements as set out in paragraph 2.3.2.2. of Annex 9A. Reagent quality and consumption "phase-in" requirements as set out in paragraphs 7.1.1.1. and 8.4.1.1. of Annex 11. Reagent quality and consumption "general" requirements as set out in paragraphs 7.1.1. and 8.4.1. of Annex 11.
The Regulation No. 85 is given merely as an example.
Engine type codes for approval marks
Engine type Code Diesel fuelled CI engine D Ethanol (ED95) fuelled CI engine ED Ethanol (E85) fuelled PI engine E85 Petrol fuelled PI engine P LPG fuelled PI engine Q Natural gas fuelled PI engine See paragraph 4.12.3.3.6. of this Regulation Annex 4
Annex 4 — Test procedure
1.Introduction
This annex is based on the world-wide harmonized heavy duty certification (WHDC), global technical regulation (gtr) No. 4).
2.Reserved1
3.Definitions, symbols and abbreviations
Definitions
For the purpose of this Regulation,
"Declared maximum power (Pmax)" means the maximum power in ECE kW (net power) as declared by the manufacturer in his application for approval.
"Delay time" means the difference in time between the change of the component to be measured at the reference point and a system response of 10 per cent of the final reading (t10) with the sampling probe being defined as the reference point. For the gaseous components, this is the transport time of the measured component from the sampling probe to the detector.
"Drift" means the difference between the zero or span responses of the measurement instrument after and before an emissions test.
"Full flow dilution method" means the process of mixing the total exhaust flow with diluent prior to separating a fraction of the diluted exhaust stream for analysis.
"High speed (nhi)" means the highest engine speed where 70 per cent of the declared maximum power occurs.
"Low speed (nlo)" means the lowest engine speed where 55 per cent of the declared maximum power occurs.
"Maximum power (Pmax)" means the maximum power in kW as specified by the manufacturer.
"Maximum torque speed" means the engine speed at which the maximum torque is obtained from the engine, as specified by the manufacturer.
"Normalized torque" means engine torque in per cent normalized to the maximum available torque at an engine speed.
The numbering of this annex is consistent with the numbering of gtr No. 4 on WHDC. However, some sections of the WHDC gtr are not needed in this annex.
"Operator demand" means an engine operator's input to control engine output. The operator may be a person (i.e., manual), or a governor (i.e., automatic) that mechanically or electronically signals an input that demands engine output. Input may be from an accelerator pedal or signal, a throttle-control lever or signal, a fuel lever or signal, a speed lever or signal, or a governor setpoint or signal.
"Partial flow dilution method" means the process of separating a part from the total exhaust flow, then mixing it with an appropriate amount of diluent prior to the particulate sampling filter.
"Ramped steady state test cycle" means a test cycle with a sequence of steady state engine test modes with defined speed and torque criteria at each mode and defined ramps between these modes (WHSC).
"Rated speed" means the maximum full load speed allowed by the governor as specified by the manufacturer in his sales and service literature, or, if such a governor is not present, the speed at which the maximum power is obtained from the engine, as specified by the manufacturer in his sales and service literature.
"Response time" means the difference in time between the change of the component to be measured at the reference point and a system response of 90 per cent of the final reading (t90) with the sampling probe being defined as the reference point, whereby the change of the measured component is at least 60 per cent full scale (FS) and takes place in less than 0.1 second. The system response time consists of the delay time to the system and of the rise time of the system.
"Rise time" means the difference in time between the 10 per cent and 90 per cent response of the final reading (t90 – t10).
"Span response" means the mean response to a span gas during a 30 s time interval.
"Specific emissions" means the mass emissions expressed in g/kWh.
"Test cycle" means a sequence of test points each with a defined speed and torque to be followed by the engine under steady state (WHSC) or transient operating conditions (WHTC).
"Transformation time" means the difference in time between the change of the component to be measured at the reference point and a system response of 50 per cent of the final reading (t50) with the sampling probe being defined as the reference point. The transformation time is used for the signal alignment of different measurement instruments.
"Transient test cycle" means a test cycle with a sequence of normalized speed and torque values that vary relatively quickly with time (WHTC).
"Zero response" means the mean response to a zero gas during a 30 s time interval.
Annex 4
General symbols
Symbol Unit Term
a1 - Slope of the regression a0 - y intercept of the regression A/Fst - Stoichiometric air to fuel ratio c ppm/Vol per cent Concentration cd ppm/Vol per cent Concentration on dry basis cw ppm/Vol per cent Concentration on wet basis cb ppm/Vol per cent Background concentration Cd - Discharge coefficient of SSV cgas ppm/Vol per cent Concentration on the gaseous components cs particles per Average concentration of particles from the cubic centimetre diluted exhaust gas corrected to standard conditions (273.2 K and 101.33 kPa) particles per cubic centimetre cs,i particles per A discrete measurement of particle cubic centimetre concentration in the diluted gas exhaust from the particle counter, corrected for coincidence and to standard conditions (273.2 K and 101.33 kPa) d m Diameter di Particle electrical mobility diameter (30, 50 or 100 nm) dV m Throat diameter of venturi D0 m /s PDP calibration intercept D - Dilution factor
Symbol Unit Term
t s Time interval e The number of particles emitted per kWh egas g/kWh Specific emission of gaseous components ePM g/kWh Specific emission of particulates er g/kWh Specific emission during regeneration ew g/kWh Weighted specific emission ECO2 per cent CO2 quench of NOx analyzer EE per cent Ethane efficiency EH2O per cent Water quench of NOx analyzer EM per cent Methane efficiency ENOx per cent Efficiency of NOx converter f Hz Data sampling rate fa - Laboratory atmospheric factor Fs - Stoichiometric factor
- Mean particle concentration reduction factor of fr the volatile particle remover specific to the dilution settings used for the test Ha g/kg Absolute humidity of the intake air Hd g/kg Absolute humidity of the diluent i - Subscript denoting an instantaneous measurement (e.g. 1 Hz) k - Calibration factor to correct the particle number counter measurements to the level of the reference instrument where this is not applied internally within the particle number counter. Where the calibration factor is applied internally within the particle number counter, a value of 1 shall be used for k in the above equation kc - Carbon specific factor kf,d m /kg fuel Combustion additional volume of dry exhaust kf,w m /kg fuel Combustion additional volume of wet exhaust kh,D - Humidity correction factor for NOx for CI engines kh,G - Humidity correction factor for NOx for PI engines
Annex 4
Symbol Unit Term
kr The regeneration adjustment, according to paragraph 6.6.2., or in the case of engines without periodically regenerating after- treatment kr = 1 kr,d Downward regeneration adjustment factor - kr,u Upward regeneration adjustment factor - kw,a - Dry to wet correction factor for the intake air kw,d - Dry to wet correction factor for the diluent kw,e - Dry to wet correction factor for the diluted exhaust gas kw,r - Dry to wet correction factor for the raw exhaust gas KV - CFV calibration function - Excess air ratio mb mg Particulate sample mass of the diluent collected md kg Mass of the diluent sample passed through the particulate sampling filters med kg Total diluted exhaust mass over the cycle medf kg Mass of equivalent diluted exhaust gas over the test cycle mew kg Total exhaust mass over the cycle mex kg Total mass of diluted exhaust gas extracted from the dilution tunnel for particle number sampling mf mg Particulate sampling filter mass mgas g Mass of gaseous emissions over the test cycle mp mg Particulate sample mass collected mPM g Mass of particulate emissions over the test cycle mPM,corr g/test Mass of particulates corrected for extraction of particle number sample flow mse kg Exhaust sample mass over the test cycle msed kg Mass of diluted exhaust gas passing the dilution tunnel msep kg Mass of diluted exhaust gas passing the particulate collection filters mssd kg Mass of secondary diluent M Nm Torque
Symbol Unit Term
Ma g/mol Molar mass of the intake air Md g/mol Molar mass of the diluent Me g/mol Molar mass of the exhaust Mf Nm Torque absorbed by auxiliaries/equipment to be fitted Mgas g/mol Molar mass of gaseous components Mr Nm Torque absorbed by auxiliaries/equipment to be removed N - Number of particles emitted over the test cycle n - Number of measurements nr - Number of measurements with regeneration -1 n min Engine rotational speed nhi min-1 High engine speed -1 nlo min Low engine speed -1 npref min Preferred engine speed np r/s PDP pump speed Ncold - The total number of particles emitted over the WHTC cold test cycle Nhot - The total number of particles emitted over the WHTC hot test cycle Nin Upstream particle number concentration Nout Downstream particle number concentration pa kPa Saturation vapour pressure of engine intake air pb kPa Total atmospheric pressure pd kPa Saturation vapour pressure of the diluent pp kPa Absolute pressure pr kPa Water vapour pressure after cooling bath ps kPa Dry atmospheric pressure P kW Power Pf kW Power absorbed by auxiliaries/equipment to be fitted Pr kW Power absorbed by auxiliaries/equipment to be removed qex kg/s Particle number sample mass flow rate qmad kg/s Intake air mass flow rate on dry basis
Annex 4
Symbol Unit Term qmaw kg/s Intake air mass flow rate on wet basis qmCe kg/s Carbon mass flow rate in the raw exhaust gas qmCf kg/s Carbon mass flow rate into the engine qmCp kg/s Carbon mass flow rate in the partial flow dilution system qmdew kg/s Diluted exhaust gas mass flow rate on wet basis qmdw kg/s Diluent mass flow rate on wet basis qmedf kg/s Equivalent diluted exhaust gas mass flow rate on wet basis qmew kg/s Exhaust gas mass flow rate on wet basis qmex kg/s Sample mass flow rate extracted from dilution tunnel qmf kg/s Fuel mass flow rate qmp kg/s Sample flow of exhaust gas into partial flow dilution system qsw kg/s Mass flow rate fed back into dilution tunnel to compensate for particle number sample extraction qvCVS m³/s CVS volume rate qvs dm³/min System flow rate of exhaust analyzer system qvt cm³/min Tracer gas flow rate r 2
- Coefficient of determination rd - Dilution ratio rD - Diameter ratio of SSV rh - Hydrocarbon response factor of the FID rm - Methanol response factor of the FID rp - Pressure ratio of SSV rs - Average sample ratio s Standard deviation kg/m³ Density e kg/m³ Exhaust gas density - Standard deviation T K Absolute temperature Ta K Absolute temperature of the intake air t s Time
Symbol Unit Term
t10 s Time between step input and 10 per cent of final reading t50 s Time between step input and 50 per cent of final reading t90 s Time between step input and 90 per cent of final reading u - Ratio between the densities (or molar masses) of the gas components and the exhaust gas divided by 1,000 V0 m3/r PDP gas volume pumped per revolution Vs dm³ System volume of exhaust analyzer bench Wact kWh Actual cycle work of the test cycle Wact,cold kWh The actual cycle work over the WHTC cold test cycle according to paragraph 7.8.6. Wact, hot kWh The actual cycle work over the WHTC hot test cycle according to paragraph 7.8.6. Wref kWh Reference cycle work of the test cycle X0 m3/r PDP calibration function
Symbols and abbreviations for the fuel composition
wALF Hydrogen content of fuel, per cent mass wBET Carbon content of fuel, per cent mass wGAM Sulphur content of fuel, per cent mass wDEL Nitrogen content of fuel, per cent mass wEPS Oxygen content of fuel, per cent mass Molar hydrogen ratio (H/C) Molar sulphur ratio (S/C) Molar nitrogen ratio (N/C) Molar oxygen ratio (O/C) referring to a fuel CHONS
Annex 4
Symbols and abbreviations for the chemical components
C1 Carbon 1 equivalent hydrocarbon CH4 Methane C2H6 Ethane C3H8 Propane CO Carbon monoxide CO2 Carbon dioxide DOP Di-octylphtalate HC Hydrocarbons H2O Water NMHC Non-methane hydrocarbons NOx Oxides of nitrogen NO Nitric oxide NO2 Nitrogen dioxide PM Particulate matter
Abbreviations
CFV Critical flow venturi CLD Chemiluminescent detector CVS Constant volume sampling deNOx NOx after-treatment system EGR Exhaust gas recirculation ET Evaporation tube FID Flame ionization detector FTIR Fourier transform infrared analyser GC Gas chromatograph HCLD Heated chemiluminescent detector HFID Heated flame ionization detector LDS Laser diode spectrometer LPG Liquefied petroleum gas NDIR Non-dispersive infrared (analyzer) NG Natural gas NMC Non-methane cutter OT Outlet tube
PDP Positive displacement pump Per cent FS Per cent of full scale PCF Particle pre-classifier PFS Partial flow system PNC Particle number counter PND Particle number diluter PTS Particle transfer system PTT Particle transfer tube SSV Subsonic venturi VGT Variable geometry turbine VPR Volatile particle remover WHSC World harmonised steady state cycle WHTC World harmonised transient cycle
4.General requirements
The engine system shall be so designed, constructed and assembled as to enable the engine in normal use to comply with the provisions of this annex during its useful life, as defined in this Regulation, including when installed in the vehicle.
5.Performance requirements
Emission of gaseous and particulate pollutants
The emissions of gaseous and particulate pollutants by the engine shall be determined on the WHTC and WHSC test cycles, as described in paragraph 7. The measurement systems shall meet the linearity requirements in paragraph 9.2. and the specifications in paragraph 9.3. (gaseous emissions measurement), paragraph 9.4. (particulate measurement) and in Appendix 2 to this annex. Other systems or analyzers may be approved by the Type Approval Authority, if it is found that they yield equivalent results in accordance with paragraph 5.1.1.
Equivalency
The determination of system equivalency shall be based on a seven-sample pair (or larger) correlation study between the system under consideration and one of the systems of this annex. "Results" refer to the specific cycle weighted emissions value. The correlation testing is to be performed at the same laboratory, test cell, and on the same engine, and is preferred to be run concurrently. The equivalency of the sample pair averages shall be determined by F-test and t-test statistics as described in Appendix 3, paragraph A.3.3., obtained under the laboratory test
Annex 4
cell and the engine conditions described above. Outliers shall be determined in accordance with ISO 5725 and excluded from the database. The systems to be used for correlation testing shall be subject to the approval by the Type Approval Authority.
Engine family
General
An engine family is characterized by design parameters. These shall be common to all engines within the family. The engine manufacturer may decide which engines belong to an engine family, as long as the membership criteria listed in paragraph 5.2.3. are respected. The engine family shall be approved by the Type Approval Authority. The manufacturer shall provide to the Type Approval Authority the appropriate information relating to the emission levels of the members of the engine family.
Special cases
In some cases there may be interaction between parameters. This shall be taken into consideration to ensure that only engines with similar exhaust emission characteristics are included within the same engine family. These cases shall be identified by the manufacturer and notified to the Type Approval Authority. It shall then be taken into account as a criterion for creating a new engine family. In case of devices or features, which are not listed in paragraph 5.2.3. and which have a strong influence on the level of emissions, this equipment shall be identified by the manufacturer on the basis of good engineering practice, and shall be notified to the Type Approval Authority. It shall then be taken into account as a criterion for creating a new engine family. In addition to the parameters listed in paragraph 5.2.3., the manufacturer may introduce additional criteria allowing the definition of families of more restricted size. These parameters are not necessarily parameters that have an influence on the level of emissions.
Parameters defining the engine family
Combustion cycle
(a) 2-stroke cycle;
(b) 4-stroke cycle;
(c) Rotary engine;
(d) Others.
Configuration of the cylinders
Position of the cylinders in the block
(a) V;
(b) In line;
(c) Radial;
(d) Others (F, W, etc.).
Relative position of the cylinders
Engines with the same block may belong to the same family as long as their bore center-to-center dimensions are the same.
Main cooling medium
(a) Air;
(b) Water;
(c) Oil.
Individual cylinder displacement
Engine with a unit cylinder displacement ≥ 0.75 dm³
In order for engines with a unit cylinder displacement of ≥ 0.75 dm³ to be considered to belong to the same engine family, the spread of their individual cylinder displacements shall not exceed 15 per cent of the largest individual cylinder displacement within the family.
Engine with a unit cylinder displacement < 0.75 dm³
In order for engines with a unit cylinder displacement of < 0.75 dm³ to be considered to belong to the same engine family, the spread of their individual cylinder displacements shall not exceed 30 per cent of the largest individual cylinder displacement within the family.
Engine with other unit cylinder displacement limits
Engines with an individual cylinder displacement that exceeds the limits defined in paragraphs 5.2.3.4.1. and 5.2.3.4.2. may be considered to belong to the same family with the approval of the Type Approval Authority. The approval shall be based on technical elements (calculations, simulations, experimental results etc.) showing that exceeding the limits does not have a significant influence on the exhaust emissions.
Method of air aspiration
(a) Naturally aspirated;
(b) Pressure charged;
(c) Pressure charged with charge cooler.
Fuel type
(a) Diesel;
(b) Natural gas (NG);
(c) Liquefied petroleum gas (LPG);
(d) Ethanol.
Combustion chamber type
(a) Open chamber;
(b) Divided chamber;
(c) Other types.
Annex 4
Ignition Type
(a) Positive ignition;
(b) Compression ignition.
Valves and porting
(a) Configuration;
(b) Number of valves per cylinder.
Fuel supply type
(a) Liquid fuel supply type:
(i) Pump and (high pressure) line and injector;
(ii) In-line or distributor pump;
(iii) Unit pump or unit injector;
(iv) Common rail;
(v) Carburettor(s);
(vi) Others.
(b) Gas fuel supply type;
(i) Gaseous;
(ii) Liquid;
(iii) Mixing units;
(iv) Others.
(c) Other types.
Miscellaneous devices
(a) Exhaust gas recirculation (EGR);
(b) Water injection;
(c) Air injection;
(d) Others.
Electronic control strategy
The presence or absence of an electronic control unit (ECU) on the engine is regarded as a basic parameter of the family. In the case of electronically controlled engines, the manufacturer shall present the technical elements explaining the grouping of these engines in the same family, i.e. the reasons why these engines can be expected to satisfy the same emission requirements. These elements can be calculations, simulations, estimations, description of injection parameters, experimental results, etc.
Examples of controlled features are:
(a) Timing;
(b) Injection pressure;
(c) Multiple injections;
(d) Boost pressure;
(e) VGT;
(f) EGR.
Exhaust after-treatment systems
The function and combination of the following devices are regarded as membership criteria for an engine family:
(a) Oxidation catalyst;
(b) Three-way catalyst;
(c) deNOx system with selective reduction of NOx (addition of reducing agent);
(d) Other deNOx systems;
(e) Particulate trap with passive regeneration;
(f) Particulate trap with active regeneration;
(g) Other particulate traps;
(h) Other devices. When an engine has been certified without an after-treatment system, whether as parent engine or as member of the family, then this engine, when equipped with an oxidation catalyst, may be included in the same engine family, if it does not require different fuel characteristics. If it requires specific fuel characteristics (e.g. particulate traps requiring special additives in the fuel to ensure the regeneration process), the decision to include it in the same family shall be based on technical elements provided by the manufacturer. These elements shall indicate that the expected emission level of the equipped engine complies with the same limit value as the non- equipped engine. When an engine has been certified with an after-treatment system, whether as parent engine or as member of a family, whose parent engine is equipped with the same after-treatment system, then this engine, when equipped without after-treatment system, shall not be added to the same engine family.
Choice of the parent engine
Compression ignition engines
Once the engine family has been agreed by the Type Approval Authority, the parent engine of the family shall be selected using the primary criterion of the highest fuel delivery per stroke at the declared maximum torque speed. In the event that two or more engines share this primary criterion, the parent engine shall be selected using the secondary criterion of highest fuel delivery per stroke at rated speed.
Annex 4
Positive ignition engines
Once the engine family has been agreed by the Type Approval Authority, the parent engine of the family shall be selected using the primary criterion of the largest displacement. In the event that two or more engines share this primary criterion, the parent engine shall be selected using the secondary criterion in the following order of priority:
(a) The highest fuel delivery per stroke at the speed of declared rated power;
(b) The most advanced spark timing;
(c) The lowest EGR rate.
Remarks on the choice of the parent engine
The Type Approval Authority may conclude that the worst-case emission of the family can best be characterized by testing additional engines. In this case, the engine manufacturer shall submit the appropriate information to determine the engines within the family likely to have the highest emissions level. If engines within the family incorporate other features which may be considered to affect exhaust emissions, these features shall also be identified and taken into account in the selection of the parent engine. If engines within the family meet the same emission values over different useful life periods, this shall be taken into account in the selection of the parent engine.
6.Test conditions
Laboratory test conditions
The absolute temperature (T a) of the engine intake air expressed in Kelvin, and the dry atmospheric pressure (ps), expressed in kPa shall be measured and the parameter fa shall be determined according to the following provisions. In multi-cylinder engines having distinct groups of intake manifolds, such as in a "Vee" engine configuration, the average temperature of the distinct groups shall be taken. The parameter fa shall be reported with the test results. For better repeatability and reproducibility of the test results, it is recommended that the parameter fa be such that: 0.93 fa 1.07.
(a) Compression-ignition engines: Naturally aspirated and mechanically supercharged engines:
99 T 0.7 f a a (1) p 298 s Turbocharged engines with or without cooling of the intake air: 0.7 99 Ta 1.5 fa (2) p 298 s
(b) Positive ignition engines: 1.2 99 T 0.6 fa a (3) p 298 s
Engines with charge air-cooling
The charge air temperature shall be recorded and shall be, at the rated speed and full load, within 5 K of the maximum charge air temperature specified by the manufacturer. The temperature of the cooling medium shall be at least 293 K (20 °C). If a test laboratory system or external blower is used, the coolant flow rate shall be set to achieve a charge air temperature within 5 K of the maximum charge air temperature specified by the manufacturer at the rated speed and full load. Coolant temperature and coolant flow rate of the charge air cooler at the above set point shall not be changed for the whole test cycle, unless this results in unrepresentative overcooling of the charge air. The charge air cooler volume shall be based upon good engineering practice and shall be representative of the production engine's in-use installation. The laboratory system shall be designed to minimize accumulation of condensate. Any accumulated condensate shall be drained and all drains shall be completely closed before emission testing. If the engine manufacturer specifies pressure-drop limits across the charge-air cooling system, it shall be ensured that the pressure drop across the charge-air cooling system at engine conditions specified by the manufacturer is within the manufacturer's specified limit(s). The pressure drop shall be measured at the manufacturer's specified locations.
Engine power
The basis of specific emissions measurement is engine power and cycle work as determined in accordance with paragraphs 6.3.1. to 6.3.5.
General engine installation
The engine shall be tested with the auxiliaries/equipment listed in Appendix 6. If auxiliaries/equipment are not installed as required, their power shall be taken into account in accordance with paragraphs 6.3.2. to 6.3.5.
Auxiliaries/equipment to be fitted for the emissions test
If it is inappropriate to install the auxiliaries/equipment required according to Appendix 6 to this annex on the test bench, the power absorbed by them shall be determined and subtracted from the measured engine power (reference and actual) over the whole engine speed range of the WHTC and over the test speeds of the WHSC.
Auxiliaries/equipment to be removed for the test
Where the auxiliaries/equipment not required according to Appendix 6 to this annex cannot be removed, the power absorbed by them may be determined and added to the measured engine power (reference and actual) over the whole engine speed range of the WHTC and over the test speeds of the
Annex 4
WHSC. If this value is greater than 3 per cent of the maximum power at the test speed it shall be demonstrated to the Type Approval Authority.
Determination of auxiliary power
The power absorbed by the auxiliaries/equipment needs only be determined, if:
(a) Auxiliaries/equipment required according to Appendix 6 to this annex, are not fitted to the engine; and/or
(b) Auxiliaries/equipment not required according to Appendix 6 to this annex, are fitted to the engine. The values of auxiliary power and the measurement/calculation method for determining auxiliary power shall be submitted by the engine manufacturer for the whole operating area of the test cycles, and approved by the Type Approval Authority.
Engine cycle work
The calculation of reference and actual cycle work (see paragraphs 7.4.8. and 7.8.6.) shall be based upon engine power according to paragraph 6.3.1. In this case, Pf and Pr of equation 4 are zero, and P equals Pm. If auxiliaries/equipment are installed according to paragraphs 6.3.2. and/or 6.3.3., the power absorbed by them shall be used to correct each instantaneous cycle power value Pm,i, as follows:
Pi Pm,i Pf,i Pr,i (4) Where: Pm,i is the measured engine power, kW Pf,i is the power absorbed by auxiliaries/equipment to be fitted, kW Pr,i is the power absorbed by auxiliaries/equipment to be removed, kW.
Engine air intake system
An engine air intake system or a test laboratory system shall be used presenting an air intake restriction within 300 Pa of the maximum value specified by the manufacturer for a clean air cleaner at the rated speed and full load. The static differential pressure of the restriction shall be measured at the location specified by the manufacturer.
Engine exhaust system
An engine exhaust system or a test laboratory system shall be used presenting an exhaust backpressure within 80 to 100 per cent of the maximum value specified by the manufacturer at the rated speed and full load. If the maximum restriction is 5 kPa or less, the set point shall be no less than 1.0 kPa from the maximum. The exhaust system shall conform to the requirements for exhaust gas sampling, as set out in paragraphs 9.3.10. and 9.3.11.
Engine with exhaust after-treatment system
If the engine is equipped with an exhaust after-treatment system, the exhaust pipe shall have the same diameter as found in-use, or as specified by the manufacturer, for at least four pipe diameters upstream of the expansion section containing the after-treatment device. The distance from the exhaust manifold flange or turbocharger outlet to the exhaust after-treatment system shall be the same as in the vehicle configuration or within the distance specifications of the manufacturer. The exhaust backpressure or restriction shall follow the same criteria as above, and may be set with a valve. For variable-restriction after-treatment devices, the maximum exhaust restriction is defined at the after-treatment condition (degreening/ageing and regeneration/loading level) specified by the manufacturer. If the maximum restriction is 5 kPa or less, the set point shall be no less than 1.0 kPa from the maximum. The after-treatment container may be removed during dummy tests and during engine mapping, and replaced with an equivalent container having an inactive catalyst support. The emissions measured on the test cycle shall be representative of the emissions in the field. In the case of an engine equipped with an exhaust after-treatment system that requires the consumption of a reagent, the reagent used for all tests shall be declared by the manufacturer. Engines equipped with exhaust after-treatment systems with continuous regeneration do not require a special test procedure, but the regeneration process needs to be demonstrated according to paragraph 6.6.1. For engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis, as described in paragraph 6.6.2., emission results shall be adjusted to account for regeneration events. In this case, the average emission depends on the frequency of the regeneration event in terms of fraction of tests during which the regeneration occurs.
Continuous regeneration
The emissions shall be measured on an after-treatment system that has been stabilized so as to result in repeatable emissions behaviour. The regeneration process shall occur at least once during the WHTC hot start test and the manufacturer shall declare the normal conditions under which regeneration occurs (soot load, temperature, exhaust back-pressure, etc.). In order to demonstrate that the regeneration process is continuous, at least three WHTC hot start tests shall be conducted. For the purpose of this demonstration, the engine shall be warmed up in accordance with paragraph 7.4.1., the engine be soaked according to paragraph 7.6.3. and the first WHTC hot start test be run. The subsequent hot start tests shall be started after soaking according to paragraph 7.6.3. During the tests, exhaust temperatures and pressures shall be recorded (temperature before and after the after-treatment system, exhaust back pressure, etc.). If the conditions declared by the manufacturer occur during the tests and the results of the three (or more) WHTC hot start tests do not scatter by more than ±25 per cent or 0.005 g/kWh, whichever is greater, the after-treatment system is considered to be of the continuous regeneration type, and the general test provisions of paragraph 7.6. (WHTC) and paragraph 7.7. (WHSC) apply.
Annex 4
If the exhaust after-treatment system has a security mode that shifts to a periodic regeneration mode, it shall be checked according to paragraph 6.6.2. For that specific case, the applicable emission limits may be exceeded and would not be weighted.
Periodic regeneration
For an exhaust after-treatment based on a periodic regeneration process, the emissions shall be measured on at least three WHTC hot start tests, one with and two without a regeneration event on a stabilized after-treatment system, and the results be weighted in accordance with equation 5. The regeneration process shall occur at least once during the WHTC hot start test. The engine may be equipped with a switch capable of preventing or permitting the regeneration process provided this operation has no effect on the original engine calibration. The manufacturer shall declare the normal parameter conditions under which the regeneration process occurs (soot load, temperature, exhaust back- pressure, etc.) and its duration. The manufacturer shall also provide the frequency of the regeneration event in terms of number of tests during which the regeneration occurs compared to number of tests without regeneration. The exact procedure to determine this frequency shall be based upon in-use data using good engineering judgement, and shall be agreed by the type approval or certification authority. The manufacturer shall provide an after-treatment system that has been loaded in order to achieve regeneration during a WHTC test. For the purpose of this testing, the engine shall be warmed up in accordance with paragraph 7.4.1., the engine be soaked according to paragraph 7.6.3. and the WHTC hot start test be started. Regeneration shall not occur during the engine warm-up. Average specific emissions between regeneration phases shall be determined from the arithmetic mean of several approximately equidistant WHTC hot start test results (g/kWh). As a minimum, at least one WHTC hot start test as close as possible prior to a regeneration test and one WHTC hot start test immediately after a regeneration test shall be conducted. As an alternative, the manufacturer may provide data to show that the emissions remain constant (25 per cent or 0.005 g/kWh, whichever is greater) between regeneration phases. In this case, the emissions of only one WHTC hot start test may be used. During the regeneration test, all the data needed to detect regeneration shall be recorded (CO or NOx emissions, temperature before and after the after- treatment system, exhaust back pressure, etc.). During the regeneration test, the applicable emission limits may be exceeded. The test procedure is schematically shown in Figure 2.
Cooling system
An engine cooling system with sufficient capacity to maintain the engine at normal operating temperatures prescribed by the manufacturer shall be used.
Lubricating oil
The lubricating oil shall be specified by the manufacturer and be representative of lubricating oil available on the market; the specifications of the lubricating oil used for the test shall be recorded and presented with the results of the test.
Specification of the reference fuel
The reference fuels are specified in Annex 5. The fuel temperature shall be in accordance with the manufacturer's recommendations.
Crankcase emissions
No crankcase emissions shall be discharged directly into the ambient atmosphere, with the following exception: engines equipped with turbochargers, pumps, blowers, or superchargers for air induction may discharge crankcase emissions to the ambient atmosphere if the emissions are added to the exhaust emissions (either physically or mathematically) during
all emission testing. Manufacturers taking advantage of this exception shall install the engines so that all crankcase emission can be routed into the emissions sampling system. For the purpose of this paragraph, crankcase emissions that are routed into the exhaust upstream of exhaust after-treatment during all operation are not considered to be discharged directly into the ambient atmosphere. Open crankcase emissions shall be routed into the exhaust system for emission measurement, as follows:
(a) The tubing materials shall be smooth-walled, electrically conductive, and not reactive with crankcase emissions. Tube lengths shall be minimized as far as possible;
(b) The number of bends in the laboratory crankcase tubing shall be minimized, and the radius of any unavoidable bend shall be maximized;
(c) The laboratory crankcase exhaust tubing shall be heated, thin-walled or insulated and shall meet the engine manufacturer's specifications for crankcase back pressure;
(d) The crankcase exhaust tubing shall connect into the raw exhaust downstream of any after-treatment system, downstream of any installed exhaust restriction, and sufficiently upstream of any sample probes to ensure complete mixing with the engine's exhaust before sampling. The crankcase exhaust tube shall extend into the free stream of exhaust to avoid boundary-layer effects and to promote mixing. The crankcase exhaust tube's outlet may orient in any direction relative to the raw exhaust flow.
Paragraphs 6.11.1. and 6.11.2. shall apply to positive-ignition engines fuelled with petrol or E85.
The pressure in the crankcase shall be measured over the emissions test cycles at an appropriate location. The pressure in the intake manifold shall be measured to within ±1 kPa.
Compliance with paragraph 6.10. shall be deemed satisfactory if, in every condition of measurement set out in paragraph 6.11.1., the pressure measured in the crankcase does not exceed the atmospheric pressure prevailing at the time of measurement.
7.Test procedures
Principles of emissions measurement
To measure the specific emissions, the engine shall be operated over the test cycles defined in paragraphs 7.2.1. and 7.2.2. The measurement of specific emissions requires the determination of the mass of components in the exhaust and the corresponding engine cycle work. The components are determined by the sampling methods described in paragraphs 7.1.1. and
Annex 4
Continuous sampling
In continuous sampling, the component's concentration is measured continuously from raw or dilute exhaust. This concentration is multiplied by the continuous (raw or dilute) exhaust flow rate at the emission sampling location to determine the component's mass flow rate. The component's emission is continuously summed over the test cycle. This sum is the total mass of the emitted component.
Batch sampling
In batch sampling, a sample of raw or dilute exhaust is continuously extracted and stored for later measurement. The extracted sample shall be proportional to the raw or dilute exhaust flow rate. Examples of batch sampling are collecting diluted gaseous components in a bag and collecting particulate matter (PM) on a filter. The batch sampled concentrations are multiplied by the total exhaust mass or mass flow (raw or dilute) from which it was extracted during the test cycle. This product is the total mass or mass flow of the emitted component. To calculate the PM concentration, the PM deposited onto a filter from proportionally extracted exhaust shall be divided by the amount of filtered exhaust.
Measurement procedures
This annex applies two measurement procedures that are functionally equivalent. Both procedures may be used for both the WHTC and the WHSC test cycle:
(a) The gaseous components are sampled continuously in the raw exhaust gas, and the particulates are determined using a partial flow dilution system;
(b) The gaseous components and the particulates are determined using a full flow dilution system (CVS system). Any combination of the two principles (e.g. raw gaseous measurement and full flow particulate measurement) is permitted.
Test cycles
Transient test cycle WHTC
The transient test cycle WHTC is listed in Appendix 1 as a second-by-second sequence of normalized speed and torque values. In order to perform the test on an engine test cell, the normalized values shall be converted to the actual values for the individual engine under test based on the engine-mapping curve. The conversion is referred to as denormalization, and the test cycle so developed as the reference cycle of the engine to be tested. With those references speed and torque values, the cycle shall be run on the test cell, and the actual speed, torque and power values shall be recorded. In order to validate the test run, a regression analysis between reference and actual speed, torque and power values shall be conducted upon completion of the test. For calculation of the brake specific emissions, the actual cycle work shall be calculated by integrating actual engine power over the cycle. For cycle validation, the actual cycle work shall be within prescribed limits of the reference cycle work.
For the gaseous pollutants, continuous sampling (raw or dilute exhaust gas) or batch sampling (dilute exhaust gas) may be used. The particulate sample shall be diluted with a conditioned diluent (such as ambient air), and collected on a single suitable filter. The WHTC is shown schematically in
Ramped steady state test cycle WHSC
The ramped steady state test cycle WHSC consists of a number of normalized speed and load modes which shall be converted to the reference values for the individual engine under test based on the engine-mapping curve. The engine shall be operated for the prescribed time in each mode, whereby engine speed and load shall be changed linearly within 20 1 seconds. In order to validate the test run, a regression analysis between reference and actual speed, torque and power values shall be conducted upon completion of the test. The concentration of each gaseous pollutant, exhaust flow and power output shall be determined over the test cycle. The gaseous pollutants may be recorded continuously or sampled into a sampling bag. The particulate sample shall be diluted with a conditioned diluent (such as ambient air). One sample over the complete test procedure shall be taken, and collected on a single suitable filter. For calculation of the brake specific emissions, the actual cycle work shall be calculated by integrating actual engine power over the cycle. The WHSC is shown in Table 1. Except for mode 1, the start of each mode is defined as the beginning of the ramp from the previous mode.
Annex 4
WHSC test cycle
Normalized speed Normalized torque Mode length (s) Mode (per cent) (per cent) incl. 20 s ramp 1 0 0 210 2 55 100 50 3 55 25 250 4 55 70 75 5 35 100 50 6 25 25 200 7 45 70 75 8 45 25 150 9 55 50 125 10 75 100 50 11 35 50 200 12 35 25 250 13 0 0 210 Sum 1,895
General test sequence
The following flow chart outlines the general guidance that should be followed during testing. The details of each step are described in the relevant paragraphs. Deviations from the guidance are permitted where appropriate, but the specific requirements of the relevant paragraphs are mandatory. For the WHTC, the test procedure consists of a cold start test following either natural or forced cool-down of the engine, a hot soak period and a hot start test. For the WHSC, the test procedure consists of a hot start test following engine preconditioning at WHSC mode 9.
Engine preparation, pre-test measurements, performance checks and calibrations
Generate engine map (maximum torque curve) paragraph 7.4.3. Generate reference test cycle paragraph 7.4.6.
Run one or more practice cycles as necessary to check engine/test cell/emissions systems
WHTC
Natural or forced engine cool-down WHSC paragraph 7.6.1.
Ready all systems for sampling and Preconditioning of engine and particulate data collection system including dilution tunnel paragraph 7.5.2. paragraph 7.7.1.
Cold start exhaust emissions test Change dummy PM filter to weighed sampling filter in system by-pass mode paragraph 7.6.2. paragraph 7.7.1. Ready all systems for sampling and data Hot soak period collection paragraph 7.6.3. paragraph 7.5.2.
Exhaust emissions test within 5 minutes Hot start exhaust emissions test after engine shut down paragraph 7.6.4. paragraphs 7.7.2. and 7.7.3.
Test cycle validation paragraphs 7.8.6./7. Data collection and evaluation paragraphs 7.6.6./7.7.4. Emissions calculation paragraph 8.
Engine mapping and reference cycle
Pre-test engine measurements, pre-test engine performance checks and pre- test system calibrations shall be made prior to the engine mapping procedure in line with the general test sequence shown in paragraph 7.3.
Annex 4
As basis for WHTC and WHSC reference cycle generation, the engine shall be mapped under full load operation for determining the speed vs. maximum torque and speed vs. maximum power curves. The mapping curve shall be used for denormalizing engine speed (paragraph 7.4.6.) and engine torque (paragraph 7.4.7.).
Engine warm-up
The engine shall be warmed up between 75 per cent and 100 per cent of its maximum power or according to the recommendation of the manufacturer and good engineering judgment. Towards the end of the warm up it shall be operated in order to stabilize the engine coolant and lube oil temperatures to within 2 per cent of its mean values for at least 2 minutes or until the engine thermostat controls engine temperature.
Determination of the mapping speed range
The minimum and maximum mapping speeds are defined as follows: Minimum mapping speed = idle speed Maximum mapping speed = nhi x 1.02 or speed where full load torque drops off to zero, whichever is smaller.
Engine mapping curve
When the engine is stabilized according to paragraph 7.4.1., the engine mapping shall be performed according to the following procedure.
(a) The engine shall be unloaded and operated at idle speed;
(b) The engine shall be operated with maximum operator demand at minimum mapping speed;
(c) The engine speed shall be increased at an average rate of 8 ± 1 min-1/s from minimum to maximum mapping speed, or at a constant rate such that it takes 4 to 6 minutes to sweep from minimum to maximum mapping speed. Engine speed and torque points shall be recorded at a sample rate of at least one point per second. When selecting option (b) in paragraph 7.4.7. for determining negative reference torque, the mapping curve may directly continue with minimum operator demand from maximum to minimum mapping speed.
Alternate mapping
If a manufacturer believes that the above mapping techniques are unsafe or unrepresentative for any given engine, alternate mapping techniques may be used. These alternate techniques shall satisfy the intent of the specified mapping procedures to determine the maximum available torque at all engine speeds achieved during the test cycles. Deviations from the mapping techniques specified in this paragraph for reasons of safety or representativeness shall be approved by the Type Approval Authority along with the justification for their use. In no case, however, the torque curve shall be run by descending engine speeds for governed or turbocharged engines.
Replicate tests
An engine need not be mapped before each and every test cycle. An engine shall be remapped prior to a test cycle if:
(a) An unreasonable amount of time has transpired since the last map, as determined by engineering judgement; or
(b) Physical changes or recalibrations have been made to the engine which potentially affect engine performance.
Denormalization of engine speed
For generating the reference cycles, the normalized speeds of Appendix 1 (WHTC) and Table 1 (WHSC) shall be denormalized using the following equation: nref = nnorm x (0.45 x nlo + 0.45 x npref + 0.1 x nhi − nidle) x 2.0327 + nidle (9) For determination of npref, the integral of the maximum torque shall be calculated from nidle to n95h from the engine mapping curve, as determined in accordance with paragraph 7.4.3. The engine speeds in Figures 4 and 5 are defined, as follows: nnorm is the normalized speed in Appendix 1 and Table 1 divided by 100 nlo is the lowest speed where the power is 55 per cent of maximum power npref is the engine speed where the integral of max. mapped torque is 51 per cent of the whole integral between nidle and n95h nhi is the highest speed where the power is 70 per cent of maximum power nidle is the idle speed n95h is the highest speed where the power is 95 per cent of maximum power For engines (mainly positive ignition engines) with a steep governor droop curve, where fuel cut off does not permit to operate the engine up to nhi or n95h, the following provisions apply: nhi in equation 9 is replaced with nPmax 1.02 n95h is replaced with nPmax 1.02
Annex 4
Denormalization of engine torque
The torque values in the engine dynamometer schedule of Appendix 1 to this annex (WHTC) and in Table 1 (WHSC) are normalized to the maximum torque at the respective speed. For generating the reference cycles, the torque
values for each individual reference speed value as determined in paragraph 7.4.6. shall be denormalized, using the mapping curve determined according to paragraph 7.4.3., as follows:
M ref,i M norm,i M max,i M f,i M r,i (10) Where: Mnorm,i is the normalized torque, per cent Mmax,i is the maximum torque from the mapping curve, Nm Mf,i is the torque absorbed by auxiliaries/equipment to be fitted, Nm Mr,i is the torque absorbed by auxiliaries/equipment to be removed, Nm If auxiliaries/equipment are fitted in accordance with paragraph 6.3.1. and Appendix 6 to this annex, Mf and Mr are zero. The negative torque values of the motoring points (m in Appendix 1 to this annex) shall take on, for purposes of reference cycle generation, reference values determined in either of the following ways:
(a) Negative 40 per cent of the positive torque available at the associated speed point;
(b) Mapping of the negative torque required to motor the engine from maximum to minimum mapping speed;
(c) Determination of the negative torque required to motor the engine at idle and at nhi and linear interpolation between these two points.
Calculation of reference cycle work
Reference cycle work shall be determined over the test cycle by synchronously calculating instantaneous values for engine power from reference speed and reference torque, as determined in paragraphs 7.4.6. and
Instantaneous engine power values shall be integrated over the test cycle to calculate the reference cycle work Wref (kWh). If auxiliaries are not fitted in accordance with paragraph 6.3.1., the instantaneous power values shall be corrected using equation 4 in paragraph 6.3.5. The same methodology shall be used for integrating both reference and actual engine power. If values are to be determined between adjacent reference or adjacent measured values, linear interpolation shall be used. In integrating the actual cycle work, any negative torque values shall be set equal to zero and included. If integration is performed at a frequency of less than 5 Hz, and if, during a given time segment, the torque value changes from positive to negative or negative to positive, the negative portion shall be computed and set equal to zero. The positive portion shall be included in the integrated value.
Pre-test procedures
Installation of the measurement equipment
The instrumentation and sample probes shall be installed as required. The tailpipe shall be connected to the full flow dilution system, if used.
Annex 4
Preparation of measurement equipment for sampling
The following steps shall be taken before emission sampling begins:
(a) Leak checks shall be performed within 8 hours prior to emission sampling according to paragraph 9.3.4.;
(b) For batch sampling, clean storage media shall be connected, such as evacuated bags;
(c) All measurement instruments shall be started according to the instrument manufacturer's instructions and good engineering judgment;
(d) Dilution systems, sample pumps, cooling fans, and the data-collection system shall be started;
(e) The sample flow rates shall be adjusted to desired levels, using bypass flow, if desired;
(f) Heat exchangers in the sampling system shall be pre-heated or pre- cooled to within their operating temperature ranges for a test;
(g) Heated or cooled components such as sample lines, filters, coolers, and pumps shall be allowed to stabilize at their operating temperatures;
(h) Exhaust dilution system flow shall be switched on at least 10 minutes before a test sequence;
(i) Any electronic integrating devices shall be zeroed or re-zeroed, before the start of any test interval.
Checking the gas analyzers
Gas analyzer ranges shall be selected. Emission analyzers with automatic or manual range switching are permitted. During the test cycle, the range of the emission analyzers shall not be switched. At the same time the gains of an analyzer's analogue operational amplifier(s) may not be switched during the test cycle. Zero and span response shall be determined for all analyzers using internationally-traceable gases that meet the specifications of paragraph 9.3.3. FID analyzers shall be spanned on a carbon number basis of one (C1).
Preparation of the particulate sampling filter
At least one hour before the test, the filter shall be placed in a petri dish, which is protected against dust contamination and allows air exchange, and placed in a weighing chamber for stabilization. At the end of the stabilization period, the filter shall be weighed and the tare weight shall be recorded. The filter shall then be stored in a closed petri dish or sealed filter holder until needed for testing. The filter shall be used within eight hours of its removal from the weighing chamber.
Adjustment of the dilution system
The total diluted exhaust gas flow of a full flow dilution system or the diluted exhaust gas flow through a partial flow dilution system shall be set to eliminate water condensation in the system, and to obtain a filter face temperature between 315 K (42 °C) and 325 K (52 °C).
Starting the particulate sampling system
The particulate sampling system shall be started and operated on by-pass. The particulate background level of the diluent may be determined by sampling the diluent prior to the entrance of the exhaust gas into the dilution tunnel. The measurement may be done prior to or after the test. If the measurement is done both at the beginning and at the end of the cycle, the values may be averaged. If a different sampling system is used for background measurement, the measurement shall be done in parallel to the test run.
WHTC cycle run
Engine cool-down
A natural or forced cool-down procedure may be applied. For forced cool- down, good engineering judgment shall be used to set up systems to send cooling air across the engine, to send cool oil through the engine lubrication system, to remove heat from the coolant through the engine cooling system, and to remove heat from an exhaust after-treatment system. In the case of a forced after-treatment system cool down, cooling air shall not be applied until the after-treatment system has cooled below its catalytic activation temperature. Any cooling procedure that results in unrepresentative emissions is not permitted.
Cold start test
The cold-start test shall be started when the temperatures of the engine's lubricant, coolant, and after-treatment systems are all between 293 and 303 K (20 and 30 °C). The engine shall be started using one of the following methods:
(a) The engine shall be started as recommended in the owner’s manual using a production starter motor and adequately charged battery or a suitable power supply; or
(b) The engine shall be started by using the dynamometer. The engine shall be motored within 25 per cent of its typical in-use cranking speed. Cranking shall be stopped within 1 second after the engine is running. If the engine does not start after 15 seconds of cranking, cranking shall be stopped and the reason for the failure to start determined, unless the owner’s manual or the service-repair manual describes the longer cranking time as normal.
Hot soak period
Immediately upon completion of the cold start test, the engine shall be conditioned for the hot start test using a 10 ± 1 minute hot soak period.
Annex 4
Hot start test
The engine shall be started at the end of the hot soak period as defined in paragraph 7.6.3. using the starting methods given in paragraph 7.6.2.
Test sequence
The test sequence of both cold start and hot start test shall commence at the start of the engine. After the engine is running, cycle control shall be initiated so that engine operation matches the first set point of the cycle. The WHTC shall be performed according to the reference cycle as set out in paragraph 7.4. Engine speed and torque command set points shall be issued at 5 Hz (10 Hz recommended) or greater. The set points shall be calculated by linear interpolation between the 1 Hz set points of the reference cycle. Actual engine speed and torque shall be recorded at least once every second during the test cycle (1 Hz), and the signals may be electronically filtered.
Collection of emission relevant data
At the start of the test sequence, the measuring equipment shall be started, simultaneously:
(a) Start collecting or analyzing diluent, if a full flow dilution system is used;
(b) Start collecting or analyzing raw or diluted exhaust gas, depending on the method used;
(c) Start measuring the amount of diluted exhaust gas and the required temperatures and pressures;
(d) Start recording the exhaust gas mass flow rate, if raw exhaust gas analysis is used;
(e) Start recording the feedback data of speed and torque of the dynamometer. If raw exhaust measurement is used, the emission concentrations ((NM)HC, CO and NOx) and the exhaust gas mass flow rate shall be measured continuously and stored with at least 2 Hz on a computer system. All other data may be recorded with a sample rate of at least 1 Hz. For analogue analyzers the response shall be recorded, and the calibration data may be applied online or offline during the data evaluation. If a full flow dilution system is used, HC and NOx shall be measured continuously in the dilution tunnel with a frequency of at least 2 Hz. The average concentrations shall be determined by integrating the analyzer signals over the test cycle. The system response time shall be no greater than 20 seconds, and shall be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO, CO 2, and NMHC may be determined by integration of continuous measurement signals or by analyzing the concentrations in the sample bag, collected over the cycle. The concentrations of the gaseous pollutants in the diluent shall be determined prior to the point where the exhaust enters into the dilution tunnel by integration or by collecting into the background bag. All other parameters that need to be measured shall be recorded with a minimum of one measurement per second (1 Hz).
Particulate sampling
At the start of the test sequence, the particulate sampling system shall be switched from by-pass to collecting particulates. If a partial flow dilution system is used, the sample pump(s) shall be controlled, so that the flow rate through the particulate sample probe or transfer tube is maintained proportional to the exhaust mass flow rate as determined in accordance with paragraph 9.4.6.1. If a full flow dilution system is used, the sample pump(s) shall be adjusted so that the flow rate through the particulate sample probe or transfer tube is maintained at a value within ±2.5 per cent of the set flow rate. If flow compensation (i.e., proportional control of sample flow) is used, it shall be demonstrated that the ratio of main tunnel flow to particulate sample flow does not change by more than ±2.5 per cent of its set value (except for the first 10 seconds of sampling). The average temperature and pressure at the gas meter(s) or flow instrumentation inlet shall be recorded. If the set flow rate cannot be maintained over the complete cycle within ±2.5 per cent because of high particulate loading on the filter, the test shall be voided. The test shall be rerun using a lower sample flow rate.
Engine stalling and equipment malfunction
If the engine stalls anywhere during the cold start test, the test shall be voided. The engine shall be preconditioned and restarted according to the requirements of paragraph 7.6.2., and the test repeated. If the engine stalls anywhere during the hot start test, the hot start test shall be voided. The engine shall be soaked according to paragraph 7.6.3., and the hot start test repeated. In this case, the cold start test need not be repeated. If a malfunction occurs in any of the required test equipment during the test cycle, the test shall be voided and repeated in line with the above provisions.
WHSC cycle run
Preconditioning the dilution system and the engine
The dilution system and the engine shall be started and warmed up in accordance with paragraph 7.4.1. After warm-up, the engine and sampling system shall be preconditioned by operating the engine at mode 9 (see paragraph 7.2.2., Table 1) for a minimum of 10 minutes while simultaneously operating the dilution system. Dummy particulate emissions samples may be collected. Those sample filters need not be stabilized or weighed, and may be discarded. Flow rates shall be set at the approximate flow rates selected for testing. The engine shall be shut off after preconditioning.
Engine starting
5 1 minutes after completion of preconditioning at mode 9 as described in paragraph 7.7.1., the engine shall be started according to the manufacturer's recommended starting procedure in the owner's manual, using either a production starter motor or the dynamometer in accordance with paragraph 7.6.2.
Annex 4
Test sequence
The test sequence shall commence after the engine is running and within one minute after engine operation is controlled to match the first mode of the cycle (idle). The WHSC shall be performed according to the order of test modes listed in
Collection of emission relevant data
At the start of the test sequence, the measuring equipment shall be started, simultaneously:
(a) Start collecting or analyzing diluent, if a full flow dilution system is used;
(b) Start collecting or analyzing raw or diluted exhaust gas, depending on the method used;
(c) Start measuring the amount of diluted exhaust gas and the required temperatures and pressures;
(d) Start recording the exhaust gas mass flow rate, if raw exhaust gas analysis is used;
(e) Start recording the feedback data of speed and torque of the dynamometer. If raw exhaust measurement is used, the emission concentrations ((NM)HC, CO and NOx) and the exhaust gas mass flow rate shall be measured continuously and stored with at least 2 Hz on a computer system. All other data may be recorded with a sample rate of at least 1 Hz. For analogue analyzers the response shall be recorded, and the calibration data may be applied online or offline during the data evaluation. If a full flow dilution system is used, HC and NOx shall be measured continuously in the dilution tunnel with a frequency of at least 2 Hz. The average concentrations shall be determined by integrating the analyzer signals over the test cycle. The system response time shall be no greater than 20 seconds, and shall be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO, CO 2, and NMHC may be determined by integration of continuous measurement signals or by analyzing the concentrations in the sample bag, collected over the cycle. The concentrations of the gaseous pollutants in the diluent shall be determined prior to the point where the exhaust enters into the dilution tunnel by integration or by collecting into the background bag. All other parameters that need to be measured shall be recorded with a minimum of one measurement per second (1 Hz).
Particulate sampling
At the start of the test sequence, the particulate sampling system shall be switched from by-pass to collecting particulates. If a partial flow dilution system is used, the sample pump(s) shall be controlled, so that the flow rate through the particulate sample probe or transfer tube is maintained proportional to the exhaust mass flow rate as determined in accordance with paragraph 9.4.6.1.
If a full flow dilution system is used, the sample pump(s) shall be adjusted so that the flow rate through the particulate sample probe or transfer tube is maintained at a value within ±2.5 per cent of the set flow rate. If flow compensation (i.e., proportional control of sample flow) is used, it shall be demonstrated that the ratio of main tunnel flow to particulate sample flow does not change by more than ±2.5 per cent of its set value (except for the first 10 seconds of sampling). The average temperature and pressure at the gas meter(s) or flow instrumentation inlet shall be recorded. If the set flow rate cannot be maintained over the complete cycle within ±2.5 per cent because of high particulate loading on the filter, the test shall be voided. The test shall be rerun using a lower sample flow rate.
Engine stalling and equipment malfunction
If the engine stalls anywhere during the cycle, the test shall be voided. The engine shall be preconditioned according to paragraph 7.7.1. and restarted according to paragraph 7.7.2., and the test repeated. If a malfunction occurs in any of the required test equipment during the test cycle, the test shall be voided and repeated in line with the above provisions.
Post-test procedures
Operations after test
At the completion of the test, the measurement of the exhaust gas mass flow rate, the diluted exhaust gas volume, the gas flow into the collecting bags and the particulate sample pump shall be stopped. For an integrating analyzer system, sampling shall continue until system response times have elapsed.
Verification of proportional sampling
For any proportional batch sample, such as a bag sample or PM sample, it shall be verified that proportional sampling was maintained according to paragraphs 7.6.7. and 7.7.5. Any sample that does not fulfil the requirements shall be voided.
PM conditioning and weighing
The particulate filter shall be placed into covered or sealed containers or the filter holders shall be closed, in order to protect the sample filters against ambient contamination. Thus protected, the filter shall be returned to the weighing chamber. The filter shall be conditioned for at least one hour, and then weighed according to paragraph 9.4.5. The gross weight of the filter shall be recorded.
Drift verification
As soon as practical but no later than 30 minutes after the test cycle is complete or during the soak period, the zero and span responses of the gaseous analyzer ranges used shall be determined. For the purpose of this paragraph, test cycle is defined as follows:
(a) For the WHTC: the complete sequence cold – soak – hot;
(b) For the WHTC hot start test (paragraph 6.6.): the sequence soak – hot;
(c) For the multiple regeneration WHTC hot start test (paragraph 6.6.): the total number of hot start tests;
Annex 4
(d) For the WHSC: the test cycle. The following provisions apply for analyzer drift:
(a) The pre-test zero and span and post-test zero and span responses may be directly inserted into equation 66 of paragraph 8.6.1. without determining the drift;
(b) If the drift between the pre-test and post-test results is less than 1 per cent of full scale, the measured concentrations may be used uncorrected or may be corrected for drift according to paragraph 8.6.1.;
(c) If the drift difference between the pre-test and post-test results is equal to or greater than 1 per cent of full scale, the test shall be voided or the measured concentrations shall be corrected for drift according to paragraph 8.6.1.
Analysis of gaseous bag sampling
As soon as practical, the following shall be performed:
(a) Gaseous bag samples shall be analyzed no later than 30 minutes after the hot start test is complete or during the soak period for the cold start test;
(b) Background samples shall be analyzed no later than 60 minutes after the hot start test is complete.
Validation of cycle work
Before calculating actual cycle work, any points recorded during engine starting shall be omitted. Actual cycle work shall be determined over the test cycle by synchronously using actual speed and actual torque values to calculate instantaneous values for engine power. Instantaneous engine power values shall be integrated over the test cycle to calculate the actual cycle work Wact (kWh). If auxiliaries/equipment are not fitted in accordance with paragraph 6.3.1., the instantaneous power values shall be corrected using equation 4 in paragraph 6.3.5. The same methodology as described in paragraph 7.4.8. shall be used for integrating actual engine power. The actual cycle work Wact is used for comparison to the reference cycle work Wref and for calculating the brake specific emissions (see paragraph 8.6.3.). Wact shall be between 85 per cent and 105 per cent of W ref
Validation statistics of the test cycle
Linear regressions of the actual values (nact, Mact, Pact) on the reference values (nref, Mref, Pref) shall be performed for both the WHTC and the WHSC. To minimize the biasing effect of the time lag between the actual and reference cycle values, the entire engine speed and torque actual signal sequence may be advanced or delayed in time with respect to the reference speed and torque sequence. If the actual signals are shifted, both speed and torque shall be shifted by the same amount in the same direction.
The method of least squares shall be used, with the best-fit equation having the form: y = a 1x + a 0 (11) Where: y is the actual value of speed (min-1), torque (Nm), or power (kW) a1 is the slope of the regression line x is the reference value of speed (min-1), torque (Nm), or power (kW) a0 is the y intercept of the regression line The standard error of estimate (SEE) of y on x and the coefficient of determination (r²) shall be calculated for each regression line. It is recommended that this analysis be performed at 1 Hz. For a test to be considered valid, the criteria of Table 2 (WHTC) or Table 3 (WHSC) shall be met.
Regression line tolerances for the WHTC
Speed Torque Power
Standard error of estimate maximum 5 per cent of maximum 10 per cent of maximum 10 per cent of
(SEE) of y on x maximum test speed maximum engine torque maximum engine power
Slope of the regression line, 0.95 to 1.03 0.83 - 1.03 0.89 - 1.03
a1
Coefficient of minimum 0.970 minimum 0.850 minimum 0.910
determination, r²
y intercept of the regression maximum 10 per cent of ±20 Nm or 2 per cent of ±4 kW or 2 per cent of
line, a0 idle speed maximum torque whichever maximum power whichever
is greater is greaterRegression line tolerances for the WHSC
Speed Torque Power
Standard error of estimate maximum 1 per cent of maximum 2 per cent of maximum 2 per cent of
(SEE) of y on x maximum test speed maximum engine torque maximum engine power
Slope of the regression line, a1 0.99 to 1.01 0.98 - 1.02 0.98 - 1.02
Coefficient of determination, r² minimum 0.990 minimum 0.950 minimum 0.950
y intercept of the regression maximum 1 per cent of ±20 Nm or 2 per cent of ±4 kW or 2 per cent of
line, a0 maximum test speed maximum torque whichever maximum power whichever
is greater is greater
Annex 4
For regression purposes only, point omissions are permitted where noted inbefore doing the regression calculation. However, those points shall
not be omitted for the calculation of cycle work and emissions. Point omission may be applied to the whole or to any part of the cycle. Permitted point omissions from regression analysis Event Conditions Permitted point omissions Minimum operator nref = 0 per cent speed and power demand (idle point) and Mref = 0 per cent and Mact > (Mref - 0.02 Mmax. mapped torque) and Mact < (Mref + 0.02 Mmax. mapped torque) Minimum operator Mref < 0 per cent power and torque demand (motoring point) Minimum operator nact ≤ 1.02 nref and Mact > Mref power and either torque demand or or speed nact > nref and Mact ≤ Mref' or nact > 1.02 nref and Mref < Mact ≤ (Mref + 0.02 Mmax. mapped torque) Maximum operator nact < nref and Mact ≥ Mref power and either torque demand or or speed nact ≥ 0.98 nref and Mact < Mref or nact < 0.98 nref and Mref > Mact ≥ (Mref - 0.02 Mmax. mapped torque)
8.Emission calculation
The final test result shall be rounded in one step to the number of places to the right of the decimal point indicated by the applicable emission standard plus one additional significant figure, in accordance with ASTM E 29-06B. No rounding of intermediate values leading to the final break-specific emission result is permitted. Calculation of hydrocarbons and/or non-methane hydrocarbons is based on the following molar carbon/hydrogen/oxygen ratios (C/H/O) of the fuel: CH1.86O0.006 for diesel (B7), CH2.92O0.46 for ethanol for dedicated C.I. engines (ED95), CH1.93O0.032 for petrol (E10), CH2.74O0.385 for ethanol (E85),
CH2.525 for LPG (liquefied petroleum gas), CH4 for NG (natural gas) and biomethane. Examples of the calculation procedures are given in Appendix 5 to this annex. Emissions calculation on a molar basis, in accordance with Annex 7 of gtr No. 11 concerning the exhaust emission test protocol for Non-Road Mobile Machinery (NRMM), is permitted with the prior agreement of the Type Approval Authority.
Dry/wet correction
If the emissions are measured on a dry basis, the measured concentration shall be converted to a wet basis according to the following equation:
c k xc w w d (12) Where: cd is the dry concentration in ppm or per cent volume kw is the dry/wet correction factor (kw,a, kw,e, or kw,d depending on respective equation used)
Raw exhaust gas q 1,2442 H a 111,19 wALF mf,i qmad,i (13) k w,a 1 1,008 qmf,i 773,4 1,2442 H a k f 1 000 qmad,i or
q 1,2442 H a 111,19 wALF mf,i qmad,i Pr (14) k w,a 1 1 qmf,i Pb 773,4 1,2442 H a kf 1 000 qmad,i or
1 k w,a 1 k w1 1,008 (15) 1 a 0,005 cCO2 cCO With k fw 0,055594 WALF 0,0080021 WDEL 0,0070046 WEPS (16)
and kw1 = 1.608 H a (17) 1,000 1.608 H a
Annex 4
Where: Ha is the intake air humidity, g water per kg dry air wALF is the hydrogen content of the fuel, per cent mass qmf,i is the instantaneous fuel mass flow rate, kg/s qmad,I is the instantaneous dry intake air mass flow rate, kg/s pr is the water vapour pressure after cooling bath, kPa pb is the total atmospheric pressure, kPa wDEL is the nitrogen content of the fuel, per cent mass wEPS is the oxygen content of the fuel, per cent mass is the molar hydrogen ratio of the fuel cCO2 is the dry CO2 concentration, per cent cCO is the dry CO concentration, per cent Equations 13 and 14 are principally identical with the factor 1.008 in equations 13 and 15 being an approximation for the more accurate denominator in equation 14.
Diluted exhaust gas
cCO2w k w,e 1 k w2 1.008 (18) 200 or
1 k w 2 k w ,e 1.008 (19) 1 cCO2d 200 With
1 1 1.608 H d 1 H a D D (20) k w2 1 1 1,000 1.608 H d 1 H a D D Where: is the molar hydrogen ratio of the fuel cCO2w is the wet CO2 concentration, per cent cCO2d is the dry CO2 concentration, per cent Hd is the diluent humidity, g water per kg dry air Ha is the intake air humidity, g water per kg dry air D is the dilution factor (see paragraph 8.5.2.3.2.)
Diluent k w,d 1 k w3 1.008 (21)
With 1.608 H d (22) k w3 1,000 1.608 H d
Where: Hd is the diluent humidity, g water per kg dry air
NOx correction for humidity
As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for humidity with the factors given in paragraph 8.2.1. or 8.2.2. The intake air humidity Ha may be derived from relative humidity measurement, dew point measurement, vapour pressure measurement or dry/wet bulb measurement using generally accepted equations.
Compression-ignition engines
15,698 H a (23) k h,D 0,832 1 000 Where: Ha is the intake air humidity, g water per kg dry air
Positive ignition engines
k 0,6272 44,030 103 H 0,862 103 H 2 h.G a a (24) Where: Ha is the intake air humidity, g water per kg dry air
Particulate filter buoyancy correction
The sampling filter mass shall be corrected for its buoyancy in air. The buoyancy correction depends on sampling filter density, air density and the density of the balance calibration weight, and does not account for the buoyancy of the PM itself. The buoyancy correction shall be applied to both tare filter mass and gross filter mass. If the density of the filter material is not known, the following densities shall be used:
(a) Teflon coated glass fiber filter: 2,300 kg/m3;
(b) Teflon membrane filter: 2,144 kg/m3;
(c) Teflon membrane filter with polymethylpentene support ring: 920 kg/m3. For stainless steel calibration weights, a density of 8,000 kg/m3 shall be used. If the material of the calibration weight is different, its density shall be known.
Annex 4
The following equation shall be used:
1 a w mf muncor (25) a 1 f
With p 28,836 p b a 8,3144 T a (26) Where: muncor is the uncorrected particulate filter mass, mg ρa is the density of the air, kg/m3 ρw is the density of balance calibration weight, kg/m3 ρf is the density of the particulate sampling filter, kg/m3 pb is the total atmospheric pressure, kPa Ta is the air temperature in the balance environment, K 28.836 is the molar mass of the air at reference humidity (282.5 K), g/mol 8.3144 is the molar gas constant The particulate sample mass mp used in paragraphs 8.4.3. and 8.5.3. shall be calculated as follows:
mp mf,G mf,T (27) Where: mf,G is the buoyancy corrected gross particulate filter mass, mg mf,T is the buoyancy corrected tare particulate filter mass, mg
Partial flow dilution (PFS) and raw gaseous measurement
The instantaneous concentration signals of the gaseous components are used for the calculation of the mass emissions by multiplication with the instantaneous exhaust mass flow rate. The exhaust mass flow rate may be measured directly, or calculated using the methods of intake air and fuel flow measurement, tracer method or intake air and air/fuel ratio measurement. Special attention shall be paid to the response times of the different instruments. These differences shall be accounted for by time aligning the signals. For particulates, the exhaust mass flow rate signals are used for controlling the partial flow dilution system to take a sample proportional to the exhaust mass flow rate. The quality of proportionality shall be checked by applying a regression analysis between sample and exhaust flow in accordance with paragraph 9.4.6.1. The complete test set up is schematically shown in Figure 6.
Determination of exhaust gas mass flow
Introduction
For calculation of the emissions in the raw exhaust gas and for controlling of a partial flow dilution system, it is necessary to know the exhaust gas mass flow rate. For the determination of the exhaust mass flow rate, one of the methods described in paragraphs 8.4.1.3. to 8.4.1.7. may be used.
Response time
For the purpose of emissions calculation, the response time of any of the methods described in paragraphs 8.4.1.3. to 8.4.1.7. shall be equal to or less than the analyzer response time of ≤ 10 seconds, as required in paragraph 9.3.5. For the purpose of controlling of a partial flow dilution system, a faster response is required. For partial flow dilution systems with online control, the response time shall be ≤ 0.3 second. For partial flow dilution systems with look ahead control based on a pre-recorded test run, the response time of the exhaust flow measurement system shall be ≤ 5 seconds with a rise time of ≤ 1 second. The system response time shall be specified by the instrument manufacturer. The combined response time requirements for the exhaust gas flow and partial flow dilution system are indicated in paragraph 9.4.6.1.
Direct measurement method
Direct measurement of the instantaneous exhaust flow shall be done by systems, such as:
(a) Pressure differential devices, like flow nozzle, (details see ISO 5167);
(b) Ultrasonic flowmeter;
Annex 4
(c) Vortex flowmeter. Precautions shall be taken to avoid measurement errors which will impact emission value errors. Such precautions include the careful installation of the device in the engine exhaust system according to the instrument manufacturers' recommendations and to good engineering practice. Especially, engine performance and emissions shall not be affected by the installation of the device. The flowmeters shall meet the linearity requirements of paragraph 9.2.
Air and fuel measurement method
This involves measurement of the airflow and the fuel flow with suitable flowmeters. The calculation of the instantaneous exhaust gas flow shall be as follows: qmew,i = qmaw,i + qmf,i (28) Where: qmew,i is the instantaneous exhaust mass flow rate, kg/s
qmaw,i is the instantaneous intake air mass flow rate, kg/s
qmf,i is the instantaneous fuel mass flow rate, kg/s The flowmeters shall meet the linearity requirements of paragraph 9.2., but shall be accurate enough to also meet the linearity requirements for the exhaust gas flow.
Tracer measurement method
This involves measurement of the concentration of a tracer gas in the exhaust. A known amount of an inert gas (e.g. pure helium) shall be injected into the exhaust gas flow as a tracer. The gas is mixed and diluted by the exhaust gas, but shall not react in the exhaust pipe. The concentration of the gas shall then be measured in the exhaust gas sample. In order to ensure complete mixing of the tracer gas, the exhaust gas sampling probe shall be located at least 1 m or 30 times the diameter of the exhaust pipe, whichever is larger, downstream of the tracer gas injection point. The sampling probe may be located closer to the injection point if complete mixing is verified by comparing the tracer gas concentration with the reference concentration when the tracer gas is injected upstream of the engine. The tracer gas flow rate shall be set so that the tracer gas concentration at engine idle speed after mixing becomes lower than the full scale of the trace gas analyzer. The calculation of the exhaust gas flow shall be as follows: qvt e (29) qmew,i 60 cmix,i cb
Where: qmew,i is the instantaneous exhaust mass flow rate, kg/s
qvt is tracer gas flow rate, cm³/min cmix,i is the instantaneous concentration of the tracer gas after mixing, ppm e is the density of the exhaust gas, kg/m³ (see Table 5) cb is the background concentration of the tracer gas in the intake air, ppm The background concentration of the tracer gas (cb) may be determined by averaging the background concentration measured immediately before the test run and after the test run. When the background concentration is less than 1 per cent of the concentration of the tracer gas after mixing (cmix.i) at maximum exhaust flow, the background concentration may be neglected. The total system shall meet the linearity requirements for the exhaust gas flow of paragraph 9.2.
Airflow and air to fuel ratio measurement method
This involves exhaust mass calculation from the air flow and the air to fuel ratio. The calculation of the instantaneous exhaust gas mass flow is as follows: 1 qmew,i qmaw,i 1 (30) A/Fst i
With
α ε 138,0 1 γ A / Fst 4 2 (31) 12,011 1,00794 α 15,9994 ε 14,0067 δ 32,065 γ
4 2 c COd 10 1 α c COd 10 3,5 c CO2d ε δ 100 - c HCw 10 4 c CO2d c COd 10 4 4 4 2 2 c 10 1 CO 3,5 c CO2d i α ε 4 4,764 1 γ c CO2d c COd 10 c HCw 10 4 2 4 (32) Where: qmaw,i is the instantaneous intake air mass flow rate, kg/s
A/Fst is the stoichiometric air to fuel ratio, kg/kg i is the instantaneous excess air ratio cCO2d is the dry CO2 concentration, per cent cCOd is the dry CO concentration, ppm cHCw is the wet HC concentration, ppm
Annex 4
Air flow meter and analyzers shall meet the linearity requirements of paragraph 9.2., and the total system shall meet the linearity requirements for the exhaust gas flow of paragraph 9.2. If an air to fuel ratio measurement equipment such as a zirconia type sensor is used for the measurement of the excess air ratio, it shall meet the specifications of paragraph 9.3.2.7.
Carbon balance method
This involves exhaust mass calculation from the fuel flow and the gaseous exhaust components that include carbon. The calculation of the instantaneous exhaust gas mass flow is as follows:
2 wBET 1.4 H qmew,i qmf,i 1 a 1 (33) 1.0828 wBET kfd kc kc 1000 With
k c cCO2d cCO2d,a 0.5441 cCOd c HCw (34) 18.522 17.355 And
kfd 0,055594 wALF 0,0080021 wDEL 0,0070046 wEPS (35)
Where: qmf,i is the instantaneous fuel mass flow rate, kg/s Ha is the intake air humidity, g water per kg dry air wBET is the carbon content of the fuel, per cent mass wALF is the hydrogen content of the fuel, per cent mass wDEL is the nitrogen content of the fuel, per cent mass wEPS is the oxygen content of the fuel, per cent mass cCO2d is the dry CO2 concentration, per cent cCO2d,a is the dry CO2 concentration of the intake air, per cent cCO is the dry CO concentration, ppm cHCw is the wet HC concentration, ppm
Determination of the gaseous components
Introduction
The gaseous components in the raw exhaust gas emitted by the engine submitted for testing shall be measured with the measurement and sampling systems described in paragraph 9.3. and Appendix 2 to this annex. The data evaluation is described in paragraph 8.4.2.2. Two calculation procedures are described in paragraphs 8.4.2.3. and 8.4.2.4., which are equivalent for the reference fuel of Annex 5. The procedure in paragraph 8.4.2.3. is more straightforward, since it uses tabulated u values for the ratio between component and exhaust gas density. The procedure in
paragraph 8.4.2.4. is more accurate for fuel qualities that deviate from the specifications in Annex 5, but requires elementary analysis of the fuel composition.
Data evaluation
The emission relevant data shall be recorded and stored in accordance with paragraph 7.6.6. For calculation of the mass emission of the gaseous components, the traces of the recorded concentrations and the trace of the exhaust gas mass flow rate shall be time aligned by the transformation time as defined in paragraph 3.1. Therefore, the response time of the exhaust gas mass flow system and each gaseous emissions analyzer shall be determined according to paragraphs 8.4.1.2. and 9.3.5., respectively, and recorded.
Calculation of mass emission based on tabulated values
The mass of the pollutants (g/test) shall be determined by calculating the instantaneous mass emissions from the raw concentrations of the pollutants and the exhaust gas mass flow, aligned for the transformation time as determined in accordance with paragraph 8.4.2.2., integrating the instantaneous values over the cycle, and multiplying the integrated values with the u values from Table 5. If measured on a dry basis, the dry/wet correction according to paragraph 8.1. shall be applied to the instantaneous concentration values before any further calculation is done. For the calculation of NOx, the mass emission shall be multiplied, where applicable, with the humidity correction factor kh,D, or kh,G, as determined according to paragraph 8.2. The following equation shall be applied: i n mgas = u gas c i 1 gas,i qmew,i f (in g/test) (36)
Where: ugas is the respective value of the exhaust component from Table 5 cgas,i is the instantaneous concentration of the component in the exhaust gas, ppm qmew,i is the instantaneous exhaust mass flow, kg/s f is the data sampling rate, Hz n is the number of measurements
Annex 4
Raw exhaust gas u values and component densities
Gas
NOx CO HC CO2 O2 CH4
Fuel e gas [kg/m3]
a
2.053 1.250 1.9636 1.4277 0.716
ugasb
Diesel
1.2943 0.001586 0.000966 0.000482 0.001517 0.001103 0.000553
(B7)
Ethanol
1.2768 0.001609 0.000980 0.000780 0.001539 0.001119 0.000561
(ED95)
CNGc 1.2661 0.001621 0.000987 0.000528d 0.001551 0.001128 0.000565
Propane 1.2805 0.001603 0.000976 0.000512 0.001533 0.001115 0.000559
Butane 1.2832 0.001600 0.000974 0.000505 0.001530 0.001113 0.000558
e
LPG 1.2811 0.001602 0.000976 0.000510 0.001533 0.001115 0.000559
Petrol
1.2931 0.001587 0.000966 0.000499 0.001518 0.001104 0.000553
(E10)
Ethanol
1.2797 0.001604 0.000977 0.000730 0.001534 0.001116 0.000559
(E85)
a
depending on fuel
b
at = 2, dry air, 273 K, 101.3 kPa
c
u accurate within 0.2 % for mass composition of: C = 66 - 76 %; H = 22 - 25 %; N = 0 - 12 %
d
NMHC on the basis of CH2.93 (for total HC the ugas coefficient of CH4 shall be used)
e
u accurate within 0.2 % for mass composition of: C3 = 70 - 90 %; C4 = 10 - 30 %Calculation of mass emission based on exact equations
The mass of the pollutants (g/test) shall be determined by calculating the instantaneous mass emissions from the raw concentrations of the pollutants, the u values and the exhaust gas mass flow, aligned for the transformation time as determined in accordance with paragraph 8.4.2.2. and integrating the instantaneous values over the cycle. If measured on a dry basis, the dry/wet correction according to paragraph 8.1. shall be applied to the instantaneous concentration values before any further calculation is done. For the calculation of NOx, the mass emission shall be multiplied with the humidity correction factor kh,D, or kh,G, as determined according to paragraph 8.2. The following equation shall be applied: i n mgas = u i 1 gas,i cgas,i qmew,i f (in g/test) (37)
Where: ugas is calculated from equation 38 or 39 cgas,i is the instantaneous concentration of the component in the exhaust gas, ppm
qmew,i is the instantaneous exhaust mass flow, kg/s f is the data sampling rate, Hz n is the number of measurements The instantaneous u values shall be calculated as follows: ugas,i = Mgas / (Me,i x 1,000) (38)
or ugas,i =gas / (e,i x 1,000) (39) With gas = Mgas / 22.414 (40) Where: Mgas is the molar mass of the gas component, g/mol (see Appendix 5 to this annex) Me,i is the instantaneous molar mass of the exhaust gas, g/mol
gas is the density of the gas component, kg/m3 e,i is the instantaneous density of the exhaust gas, kg/m3 The molar mass of the exhaust, Me, shall be derived for a general fuel composition CHONSunder the assumption of complete combustion, as follows: q mf, i 1 (41) q maw,i M e,i H a 10 3 1 q mf,i 4 2 2 2 1,00794 15 ,9994 M a
q maw,i 12,011 1,00794 15,9994 14,0067 32,065 1 H a 10 3
Where: qmaw,i is the instantaneous intake air mass flow rate on wet basis, kg/s
qmf,i is the instantaneous fuel mass flow rate, kg/s Ha is the intake air humidity, g water per kg dry air Ma is the molar mass of the dry intake air = 28.965 g/mol The exhaust density e shall be derived, as follows: 1,000 + H a 1,000 (qmf,i /qmad,i ) ρe,i = (42) 773.4 + 1.2434 H a + k fw 1,000 (qmf,i /qmad,i )
Where: qmad,i is the instantaneous intake air mass flow rate on dry basis, kg/s qmf,i is the instantaneous fuel mass flow rate, kg/s Ha is the intake air humidity, g water per kg dry air
Annex 4
kfw is the fuel specific factor of wet exhaust (equation 16) in paragraph 8.1.1.
Particulate determination
Data evaluation
The particulate mass shall be calculated according to equation 27 of paragraph 8.3. For the evaluation of the particulate concentration, the total sample mass (msep) through the filter over the test cycle shall be recorded. With the prior approval of the Type Approval Authority , the particulate mass may be corrected for the particulate level of the diluent, as determined in paragraph 7.5.6., in line with good engineering practice and the specific design features of the particulate measurement system used.
Calculation of mass emission
Depending on system design, the mass of particulates (g/test) shall be calculated by either of the methods in paragraph 8.4.3.2.1. or 8.4.3.2.2. after buoyancy correction of the particulate sample filter according to paragraph 8.3.
Calculation based on sample ratio mPM = mp / (rs x 1,000) (43) Where: mp is the particulate mass sampled over the cycle, mg rs is the average sample ratio over the test cycle With mse msep rs = (44) mew msed
Where: mse is the sample mass over the cycle, kg mew is the total exhaust mass flow over the cycle, kg msep is the mass of diluted exhaust gas passing the particulate collection filters, kg msed is the mass of diluted exhaust gas passing the dilution tunnel, kg In case of the total sampling type system, msep and msed are identical.
Calculation based on dilution ratio
mp medf mPM = (45) m sep 1,000
Where: mp is the particulate mass sampled over the cycle, mg msep is the mass of diluted exhaust gas passing the particulate collection filters, kg
medf is the mass of equivalent diluted exhaust gas over the cycle, kg The total mass of equivalent diluted exhaust gas mass over the cycle shall be determined as follows: i n medf = q i 1 medf,i f (46)
qmedf,i = qmew,i x rd,i (47)
qmdew,,i rd,i = (48) q mdew,,i qmdw,,i Where: qmedf,i is the instantaneous equivalent diluted exhaust mass flow rate, kg/s qmew,i is the instantaneous exhaust mass flow rate, kg/s rd,i is the instantaneous dilution ratio qmdew,i is the instantaneous diluted exhaust mass flow rate, kg/s qmdw,i is the instantaneous diluent mass flow rate, kg/s f is the data sampling rate, Hz n is the number of measurements
Full flow dilution measurement (CVS)
The concentration signals, either by integration over the cycle or by bag sampling, of the gaseous components shall be used for the calculation of the mass emissions by multiplication with the diluted exhaust mass flow rate. The exhaust mass flow rate shall be measured with a constant volume sampling (CVS) system, which may use a positive displacement pump (PDP), a critical flow venturi (CFV) or a subsonic venturi (SSV) with or without flow compensation. For bag sampling and particulate sampling, a proportional sample shall be taken from the diluted exhaust gas of the CVS system. For a system without flow compensation, the ratio of sample flow to CVS flow shall not vary by more than ±2.5 per cent from the set point of the test. For a system with flow compensation, each individual flow rate shall be constant within ±2.5 per cent of its respective target flow rate. The complete test set up is schematically shown in Figure 7.
Annex 4
Determination of the diluted exhaust gas flow
Introduction
For calculation of the emissions in the diluted exhaust gas, it is necessary to know the diluted exhaust gas mass flow rate. The total diluted exhaust gas flow over the cycle (kg/test) shall be calculated from the measurement values over the cycle and the corresponding calibration data of the flow measurement device (V0 for PDP, KV for CFV, Cd for SSV) by one of the methods described in paragraphs 8.5.1.2. to 8.5.1.4. If the total sample flow of particulates (msep) exceeds 0.5 per cent of the total CVS flow (med), the CVS flow shall be corrected for msep or the particulate sample flow shall be returned to the CVS prior to the flow measuring device.
PDP-CVS system
The calculation of the mass flow over the cycle is as follows, if the temperature of the diluted exhaust is kept within ±6 K over the cycle by using a heat exchanger:
med 1,293 V0 np pp 273 /(101,3 T ) (49)
Where: V0 is the volume of gas pumped per revolution under test conditions, m³/rev nP is the total revolutions of pump per test pp is the absolute pressure at pump inlet, kPa T is the average temperature of the diluted exhaust gas at pump inlet, K
If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: med,i = 1.293 x V0 x nP,i x pp x 273 / (101.3 x T) (50) Where: nP,i is the total revolutions of pump per time interval
CFV-CVS system
The calculation of the mass flow over the cycle is as follows, if the temperature of the diluted exhaust is kept within ±11 K over the cycle by using a heat exchanger: med = 1.293 x t x Kv x pp / T 0.5 (51) Where: t is the cycle time, s KV is the calibration coefficient of the critical flow venturi for standard conditions, pp is the absolute pressure at venturi inlet, kPa T is the absolute temperature at venturi inlet, K If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: med,i = 1.293 x ti x KV x pp / T 0.5 (52) Where: ti is the time interval, s
SSV-CVS system
The calculation of the mass flow over the cycle shall be as follows, if the temperature of the diluted exhaust is kept within ±11 K over the cycle by using a heat exchanger: med = 1.293 x QSSV (53) With
1 1.4286 QSSV A0 d V Cd p p rp rp 1.7143 1 4 1.4286 (54) T 1 rD rp Where:
12 is 0.006111 in SI units of m 3 K 1 min kPa mm 2 A0
Annex 4
dV is the diameter of the SSV throat, m Cd is the discharge coefficient of the SSV pp is the absolute pressure at venturi inlet, kPa T is the temperature at the venturi inlet, K p rp is the ratio of the SSV throat to inlet absolute static pressure, 1 pa
rD is the ratio of the SSV throat diameter, d, to the inlet pipe inner diameter D If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: med = 1.293 x QSSV x ti (55) Where: ti is the time interval, s The real time calculation shall be initialized with either a reasonable value for Cd, such as 0.98, or a reasonable value of Qssv. If the calculation is initialized with Qssv, the initial value of Qssv shall be used to evaluate the Reynolds number. During all emissions tests, the Reynolds number at the SSV throat shall be in the range of Reynolds numbers used to derive the calibration curve developed in paragraph 9.5.4.
Determination of the gaseous components
Introduction
The gaseous components in the diluted exhaust gas emitted by the engine submitted for testing shall be measured by the methods described in Appendix 2 to this annex. Dilution of the exhaust shall be done with filtered ambient air, synthetic air or nitrogen. The flow capacity of the full flow system shall be large enough to completely eliminate water condensation in the dilution and sampling systems. Data evaluation and calculation procedures are described in paragraphs 8.5.2.2. and 8.5.2.3.
Data evaluation
The emission relevant data shall be recorded and stored in accordance with paragraph 7.6.6.
Calculation of mass emission
Systems with constant mass flow
For systems with heat exchanger, the mass of the pollutants shall be determined from the following equation: mgas = ugas x cgas x med (in g/test) (56)
Where: ugas is the respective value of the exhaust component from Table 6 cgas is the average background corrected concentration of the component, ppm med is the total diluted exhaust mass over the cycle, kg If measured on a dry basis, the dry/wet correction according to paragraph 8.1. shall be applied. For the calculation of NOx, the mass emission shall be multiplied, if applicable, with the humidity correction factor kh,D, or kh,G, as determined according to paragraph 8.2. The u values are given in Table 6. For calculating the ugas values, the density of the diluted exhaust gas has been assumed to be equal to air density. Therefore, the ugas values are identical for single gas components, but different for HC.
Diluted exhaust gas u values and component densities
Gas
NOx CO HC CO2 O2 CH4
Fuel de gas [kg/m3]
a
2.053 1.250 1.9636 1.4277 0.716
ugasb
Diesel
1.293 0.001588 0.000967 0.000483 0.001519 0.001104 0.000553
(B7)
Ethanol
1.293 0.001588 0.000967 0.000770 0.001519 0.001104 0.000553
(ED95)
CNGc 1.293 0.001588 0.000967 0.000517d 0.001519 0.001104 0.000553
Propane 1.293 0.001588 0.000967 0.000507 0.001519 0.001104 0.000553
Butane 1.293 0.001588 0.000967 0.000501 0.001519 0.001104 0.000553
LPGe 1.293 0.001588 0.000967 0.000505 0.001519 0.001104 0.000553
Petrol
1.293 0.001588 0.000967 0.000499 0.001519 0.001104 0.000554
(E10)
Ethanol
1.293 0.001588 0.000967 0.000722 0.001519 0.001104 0.000554
(E85)
a
depending on fuel
b
at = 2, dry air, 273 K, 101.3 kPa
c
u accurate within 0.2 % for mass composition of: C = 66 - 76 %; H = 22 - 25 %; N = 0 - 12 %
d
NMHC on the basis of CH2.93 (for total HC the ugas coefficient of CH4 shall be used)
e
u accurate within 0.2 % for mass composition of: C3 = 70 - 90 %; C4 = 10 - 30 %
Alternatively, the u values may be calculated using the exact calculation
method generally described in paragraph 8.4.2.4., as follows:
M gas (57)
ugas
1 1
M d 1 M e
D D
Annex 4
Where:
Mgas is the molar mass of the gas component, g/mol (see Appendix 5 to this
annex)
Me is the molar mass of the exhaust gas, g/mol
Md is the molar mass of the diluent = 28.965 g/mol
D is the dilution factor (see paragraph 8.5.2.3.2.)Determination of the background corrected concentrations
The average background concentration of the gaseous pollutants in the diluent shall be subtracted from the measured concentrations to get the net concentrations of the pollutants. The average values of the background concentrations can be determined by the sample bag method or by continuous measurement with integration. The following equation shall be used: cgas = cgas,e - cd x (1 - (1/D)) (58) Where: cgas,e is the concentration of the component measured in the diluted exhaust gas, ppm cd is the concentration of the component measured in the diluent, ppm D is the dilution factor The dilution factor shall be calculated as follows:
a) For diesel fuelled engines and LPG fuelled gas engines FS D = (59) cCO2,e cHC,e cCO,e 10 4
b) For natural gas fuelled gas engines FS D = (60) cCO2,e c NMHC,e cCO,e 10 4 Where: cCO2,e is the wet concentration of CO2 in the diluted exhaust gas, per cent vol cHC,e is the wet concentration of HC in the diluted exhaust gas, ppm C1 cNMHC,e is the wet concentration of NMHC in the diluted exhaust gas, ppm C1 cCO,e is the wet concentration of CO in the diluted exhaust gas, ppm FS is the stoichiometric factor
The stoichiometric factor shall be calculated as follows: FS = 100 (61) 1 + 3,76 1 2 4 Where: is the molar hydrogen ratio of the fuel (H/C) Alternatively, if the fuel composition is not known, the following stoichiometric factors may be used: FS (diesel) = 13.4 FS (LPG) = 11.6 FS (NG) = 9.5 FS (E10) = 13.3 FS (E85) = 11.5
Systems with flow compensation
For systems without heat exchanger, the mass of the pollutants (g/test) shall be determined by calculating the instantaneous mass emissions and integrating the instantaneous values over the cycle. Also, the background correction shall be applied directly to the instantaneous concentration value. The following equation shall be applied:
m cgas,e u gas med cd 1 1/D u gas n mgas = ed,i (62) i 1
Where: cgas,e is the concentration of the component measured in the diluted exhaust gas, ppm cd is the concentration of the component measured in the diluent, ppm med,i is the instantaneous mass of the diluted exhaust gas, kg med is the total mass of diluted exhaust gas over the cycle, kg ugas is the tabulated value from Table 6 D is the dilution factor
Particulate determination
Calculation of mass emission
The particulate mass (g/test) shall be calculated after buoyancy correction of the particulate sample filter according to paragraph 8.3., as follows:
mp med mPM = (63) m sep 1,000
Annex 4
Where: mp is the particulate mass sampled over the cycle, mg msep is the mass of diluted exhaust gas passing the particulate collection filters, kg med is the mass of diluted exhaust gas over the cycle, kg With msep = mset - mssd (64) Where: mset is the mass of double diluted exhaust gas through particulate filter, kg mssd is the mass of secondary diluent, kg If the particulate background level of the diluent is determined in accordance with paragraph 7.5.6., the particulate mass may be background corrected. In this case, the particulate mass (g/test) shall be calculated as follows:
mp mb 1 med mPM = 1 - (65) msep msd D 1,000 Where: msep is the mass of diluted exhaust gas passing the particulate collection filters, kg med is the mass of diluted exhaust gas over the cycle, kg msd is the mass of diluent sampled by background particulate sampler, kg mb is the mass of the collected background particulates of the diluent, mg D is the dilution factor as determined in paragraph 8.5.2.3.2.
General calculations
Drift correction
With respect to drift verification in paragraph 7.8.4., the corrected concentration value shall be calculated as follows:
2 cgas cpre,z cpost,z ccor cref, z cref,s cref, z (66) c c c c pre,s post,s pre,z post,z
Where: cref,z is the reference concentration of the zero gas (usually zero), ppm cref,s is the reference concentration of the span gas, ppm cpre,z is the pre-test analyzer concentration of the zero gas, ppm cpre,s is the pre-test analyzer concentration of the span gas, ppm cpost,z is the post-test analyzer concentration of the zero gas, ppm cpost,s is the post-test analyzer concentration of the span gas, ppm cgas is the sample gas concentration, ppm
Two sets of specific emission results shall be calculated for each component in accordance with paragraph 8.6.3., after any other corrections have been applied. One set shall be calculated using uncorrected concentrations and another set shall be calculated using the concentrations corrected for drift according to equation 66. Depending on the measurement system and calculation method used, the uncorrected emissions results shall be calculated with equations 36, 37, 56, 57 or 62, respectively. For calculation of the corrected emissions, cgas in equations 36, 37, 56, 57 or 62, respectively, shall be replaced with ccor of equation 66. If instantaneous concentration values cgas,i are used in the respective equation, the corrected value shall also be applied as instantaneous value ccor,i. In equation 57, the correction shall be applied to both the measured and the background concentration. The comparison shall be made as a percentage of the uncorrected results. The difference between the uncorrected and the corrected brake-specific emission values shall be within ±4 per cent of the uncorrected brake-specific emission values or within ±4 per cent of the respective limit value, whichever is greater. If the drift is greater than 4 per cent, the test shall be voided. If drift correction is applied, only the drift-corrected emission results shall be used when reporting emissions.
Calculation of NMHC and CH4
The calculation of NMHC and CH4 depends on the calibration method used. The FID for the measurement without NMC (lower path of Appendix 2 to this annex, Figure 11), shall be calibrated with propane. For the calibration of the FID in series with NMC (upper path of Appendix 2 to this annex, Figure 11), the following methods are permitted.
(a) Calibration gas – propane; propane bypasses NMC;
(b) Calibration gas – methane; methane passes through NMC. The concentration of NMHC and CH4 shall be calculated as follows for (a):
c HC w / NMC c HC w / oNMC (1 E E ) c NMHC = (67) rh ( E E E M )
c HC w / oNMC (1 E M ) c HC w / NMC cCH 4 = (68) EE EM The concentration of NMHC and CH4 shall be calculated as follows for (b):
c HC w / oNMC (1 E M ) c HC w / NMC rh (1 E M ) c NMHC = (67a) EE EM
c HC w / NMC rh (1 E M ) c HC w / oNMC (1 E E ) cCH 4 = (68a) rh ( E E E M )
Annex 4
Where: cHC(w/NMC) is the HC concentration with sample gas flowing through the NMC, ppm cHC(w/oNMC) is the HC concentration with sample gas bypassing the NMC, ppm rh is the methane response factor as determined per paragraph 9.3.7.2. EM is the methane efficiency as determined per paragraph 9.3.8.1. EE is the ethane efficiency as determined per paragraph 9.3.8.2. If rh < 1.05, it may be omitted in equations 67, 67a and 68a.
Calculation of the specific emissions
The specific emissions egas or ePM (g/kWh) shall be calculated for each individual component in the following ways depending on the type of test cycle. For the WHSC, hot WHTC, or cold WHTC, the following equation shall be applied:
m e (69) Wact (0,14 mcold ) (0,86 mhot ) e (70) (0,14 Wact,cold ) (0,86 Wact,hot )
Where: m is the mass emission of the component, g/test Wact is the actual cycle work as determined according to paragraph 7.8.6., kWh For the WHTC, the final test result shall be a weighted average from cold start test and hot start test according to the following equation: Where: mcold is the mass emission of the component on the cold start test, g/test mhot is the mass emission of the component on the hot start test, g/test Wact,cold is the actual cycle work on the cold start test, kWh Wact,hot is the actual cycle work on the hot start test, kWh If periodic regeneration in accordance with paragraph 6.6.2. applies, the regeneration adjustment factors kr,u or kr,d shall be multiplied with or be added to, respectively, the specific emissions result e as determined in equations 69 and 70.
9.Equipment specification and verification
This annex does not contain details of flow, pressure, and temperature measuring equipment or systems. Instead, only the linearity requirements of such equipment or systems necessary for conducting an emissions test are given in paragraph 9.2.
Dynamometer specification
An engine dynamometer with adequate characteristics to perform the appropriate test cycle described in paragraphs 7.2.1. and 7.2.2. shall be used. The instrumentation for torque and speed measurement shall allow the measurement accuracy of the shaft power as needed to comply with the cycle validation criteria. Additional calculations may be necessary. The accuracy of the measuring equipment shall be such that the linearity requirements given in paragraph 9.2., Table 7 are not exceeded.
Linearity requirements
The calibration of all measuring instruments and systems shall be traceable to national (international) standards. The measuring instruments and systems shall comply with the linearity requirements given in Table 7. The linearity verification according to paragraph 9.2.1. shall be performed for the gas analyzers at least every three months or whenever a system repair or change is made that could influence calibration. For the other instruments and systems, the linearity verification shall be done as required by internal audit procedures, by the instrument manufacturer or in accordance with ISO 9000 requirements.
Linearity requirements of instruments and measurement systems
Coefficient of
Slope Standard error
Measurement system min (a1 - 1)+ a0 determination
a1 SEE
r2
Engine speed ≤ 0.05 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Engine torque ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Fuel flow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Airflow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Exhaust gas flow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Diluent flow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Diluted exhaust gas flow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Sample flow ≤ 1 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Gas analyzers ≤ 0.5 % max 0.99 - 1.01 ≤ 1 % max ≥ 0.998
Gas dividers ≤ 0.5 % max 0.98 - 1.02 ≤ 2 % max ≥ 0.990
Temperatures ≤ 1 % max 0.99 - 1.01 ≤ 1 % max ≥ 0.998
Pressures ≤ 1 % max 0.99 - 1.01 ≤ 1 % max ≥ 0.998
PM balance ≤ 1 % max 0.99 - 1.01 ≤ 1 % max ≥ 0.998
Annex 4Linearity verification
Introduction
A linearity verification shall be performed for each measurement system listed in Table 7. At least 10 reference values, or as specified otherwise, shall be introduced to the measurement system, and the measured values shall be compared to the reference values by using a least squares linear regression in accordance with equation 11 in paragraph 7.8.7.. The maximum limits in
General requirements
The measurement systems shall be warmed up according to the recommendations of the instrument manufacturer. The measurement systems shall be operated at their specified temperatures, pressures and flows.
Procedure
The linearity verification shall be run for each normally used operating range with the following steps:
(a) The instrument shall be set at zero by introducing a zero signal. For gas analyzers, purified synthetic air (or nitrogen) shall be introduced directly to the analyzer port;
(b) The instrument shall be spanned by introducing a span signal. For gas analyzers, an appropriate span gas shall be introduced directly to the analyzer port;
(c) The zero procedure of (a) shall be repeated;
(d) The verification shall be established by introducing at least 10 reference values (including zero) that are within the range from zero to the highest values expected during emission testing. For gas analyzers, known gas concentrations in accordance with paragraph 9.3.3.2. shall be introduced directly to the analyzer port;
(e) At a recording frequency of at least 1 Hz, the reference values shall be measured and the measured values recorded for 30 seconds;
(f) The arithmetic mean values over the 30 seconds period shall be used to calculate the least squares linear regression parameters according to equation 11 in paragraph 7.8.7;
(g) The linear regression parameters shall meet the requirements of paragraph 9.2., Table 7;
(h) The zero setting shall be rechecked and the verification procedure repeated, if necessary.
Gaseous emissions measurement and sampling system
Analyzer specifications
General
The analyzers shall have a measuring range and response time appropriate for the accuracy required to measure the concentrations of the exhaust gas components under transient and steady state conditions.
The electromagnetic compatibility (EMC) of the equipment shall be on a level as to minimize additional errors.
Accuracy
The accuracy, defined as the deviation of the analyzer reading from the reference value, shall not exceed ±2 per cent of the reading or ±0.3 per cent of full scale whichever is larger.
Precision
The precision, defined as 2.5 times the standard deviation of 10 repetitive responses to a given calibration or span gas, shall be no greater than 1 per cent of full scale concentration for each range used above 155 ppm (or ppm C) or 2 per cent of each range used below 155 ppm (or ppm C).
Noise
The analyzer peak-to-peak response to zero and calibration or span gases over any 10 seconds period shall not exceed 2 per cent of full scale on all ranges used.
Zero drift
The drift of the zero response shall be specified by the instrument manufacturer.
Span drift
The drift of the span response shall be specified by the instrument manufacturer.
Rise time
The rise time of the analyzer installed in the measurement system shall not exceed 2.5 seconds.
Gas drying
Exhaust gases may be measured wet or dry. A gas-drying device, if used, shall have a minimal effect on the composition of the measured gases. Chemical dryers are not an acceptable method of removing water from the sample.
Gas analyzers
Introduction
Paragraphs 9.3.2.2. to 9.2.3.7. describe the measurement principles to be used. A detailed description of the measurement systems is given in Appendix 2 to this annex. The gases to be measured shall be analyzed with the following instruments. For non-linear analyzers, the use of linearizing circuits is permitted.
Carbon monoxide (CO) analysis
The carbon monoxide analyzer shall be of the non-dispersive infrared (NDIR) absorption type.
Annex 4
Carbon dioxide (CO2) analysis
The carbon dioxide analyzer shall be of the non-dispersive infrared (NDIR) absorption type.
Hydrocarbon (HC) analysis
The hydrocarbon analyzer shall be of the heated flame ionization detector (HFID) type with detector, valves, pipework, etc. heated so as to maintain a gas temperature of 463 K ± 10 K (190 ± 10 °C). Optionally, for natural gas fuelled and PI engines, the hydrocarbon analyzer may be of the non-heated flame ionization detector (FID) type depending upon the method used (see Appendix 2 to this annex, paragraph A.2.1.3.).
Methane (CH4) and non-methane hydrocarbon (NMHC) analysis
The determination of the methane and non-methane hydrocarbon fraction shall be performed with a heated non-methane cutter (NMC) and two FIDs as per Appendix 2 to this annex, paragraph A.2.1.4. and paragraph A.2.1.5. The concentration of the components shall be determined as per paragraph 8.6.2.
Oxides of nitrogen (NOx) analysis
Two measurement instruments are specified for NOx measurement and either instrument may be used provided it meets the criteria specified in paragraphs 9.3.2.6.1. or 9.3.2.6.2., respectively. For the determination of system equivalency of an alternate measurement procedure in accordance with paragraph 5.1.1., only the CLD is permitted.
Chemiluminescent detector (CLD)
If measured on a dry basis, the oxides of nitrogen analyzer shall be of the chemiluminescent detector (CLD) or heated chemiluminescent detector (HCLD) type with a NO2/NO converter. If measured on a wet basis, a HCLD with converter maintained above 328 K (55 °C) shall be used, provided the water quench check (see paragraph 9.3.9.2.2.) is satisfied. For both CLD and HCLD, the sampling path shall be maintained at a wall temperature of 328 K to 473 K (55 °C to 200 °C) up to the converter for dry measurement and up to the analyzer for wet measurement.
Non-dispersive ultraviolet detector (NDUV)
A non-dispersive ultraviolet (NDUV) analyzer shall be used to measure NO x concentration. If the NDUV analyzer measures only NO, a NO 2/NO converter shall be placed upstream of the NDUV analyzer. The NDUV temperature shall be maintained to prevent aqueous condensation, unless a sample dryer is installed upstream of the NO2/NO converter, if used, or upstream of the analyzer.
Air to fuel measurement
The air to fuel measurement equipment used to determine the exhaust gas flow as specified in paragraph 8.4.1.6. shall be a wide range air to fuel ratio sensor or lambda sensor of Zirconia type. The sensor shall be mounted directly on the exhaust pipe where the exhaust gas temperature is high enough to eliminate water condensation.
The accuracy of the sensor with incorporated electronics shall be within: 3 per cent of reading for <2 5 per cent of reading for 2<5 10 per cent of reading for 5 To fulfil the accuracy specified above, the sensor shall be calibrated as specified by the instrument manufacturer.
Gases
The shelf life of all gases shall be respected.
Pure gases
The required purity of the gases is defined by the contamination limits given below. The following gases shall be available for operation:
a) For raw exhaust gas Purified nitrogen (Contamination 1 ppm C1, 1 ppm CO, 400 ppm CO2, 0.1 ppm NO) Purified oxygen (Purity 99.5 per cent vol O2) Hydrogen-helium mixture (FID burner fuel) (40 ± 1 per cent hydrogen, balance helium) (Contamination 1 ppm C1, 400 ppm CO2) Purified synthetic air (Contamination 1 ppm C1, 1 ppm CO, 400 ppm CO2, 0.1 ppm NO) (Oxygen content between 18-21 per cent vol.)
b) For dilute exhaust gas (optionally for raw exhaust gas) Purified nitrogen (Contamination 0.05 ppm C1, 1 ppm CO, 10 ppm CO2, 0.02 ppm NO) Purified oxygen (Purity 99.5 per cent vol O2) Hydrogen-helium mixture (FID burner fuel) (40 ± 1 per cent hydrogen, balance helium) (Contamination 0.05 ppm C1, 10 ppm CO2) Purified synthetic air (Contamination 0.05 ppm C1, 1 ppm CO, 10 ppm CO2, 0.02 ppm NO) (Oxygen content between 20.5 - 21.5 per cent vol.) If gas bottles are not available, a gas purifier may be used, if contamination levels can be demonstrated.
Annex 4
Calibration and span gases
Mixtures of gases having the following chemical compositions shall be available, if applicable. Other gas combinations are allowed provided the gases do not react with one another. The expiration date of the calibration gases stated by the manufacturer shall be recorded. C3H8 and purified synthetic air (see paragraph 9.3.3.1.); CO and purified nitrogen; NO and purified nitrogen; NO2 and purified synthetic air; CO2 and purified nitrogen; CH4 and purified synthetic air; C2H6 and purified synthetic air. The true concentration of a calibration and span gas shall be within ±1 per cent of the nominal value, and shall be traceable to national or international standards. All concentrations of calibration gas shall be given on a volume basis (volume per cent or volume ppm).
Gas dividers
The gases used for calibration and span may also be obtained by means of gas dividers (precision blending devices), diluting with purified N 2 or with purified synthetic air. The accuracy of the gas divider shall be such that the concentration of the blended calibration gases is accurate to within ±2 per cent. This accuracy implies that primary gases used for blending shall be known to an accuracy of at least 1 per cent, traceable to national or international gas standards. The verification shall be performed at between 15 and 50 per cent of full scale for each calibration incorporating a gas divider. An additional verification may be performed using another calibration gas, if the first verification has failed. Optionally, the blending device may be checked with an instrument which by nature is linear, e.g. using NO gas with a CLD. The span value of the instrument shall be adjusted with the span gas directly connected to the instrument. The gas divider shall be checked at the settings used and the nominal value shall be compared to the measured concentration of the instrument. This difference shall in each point be within ±1 per cent of the nominal value. For conducting the linearity verification according to paragraph 9.2.1., the gas divider shall be accurate to within 1 per cent.
Oxygen interference check gases
Oxygen interference check gases are a blend of propane, oxygen and nitrogen. They shall contain propane with 350 ppm C 75 ppm C hydrocarbon. The concentration value shall be determined to calibration gas tolerances by chromatographic analysis of total hydrocarbons plus impurities or by dynamic blending. The oxygen concentrations required for positive ignition and compression ignition engine testing are listed in Table 8 with the remainder being purified nitrogen.
Oxygen interference check gases
Type of engine O2 concentration (per cent) Compression ignition 21 (20 to 22) Compression and positive ignition 10 (9 to 11) Compression and positive ignition 5 (4 to 6) Positive ignition 0 (0 to 1)
Leak check
A system leak check shall be performed. The probe shall be disconnected from the exhaust system and the end plugged. The analyzer pump shall be switched on. After an initial stabilization period all flowmeters will read approximately zero in the absence of a leak. If not, the sampling lines shall be checked and the fault corrected. The maximum allowable leakage rate on the vacuum side shall be 0.5 per cent of the in-use flow rate for the portion of the system being checked. The analyzer flows and bypass flows may be used to estimate the in-use flow rates. Alternatively, the system may be evacuated to a pressure of at least 20 kPa vacuum (80 kPa absolute). After an initial stabilization period the pressure increase p (kPa/min) in the system shall not exceed:
p = p / Vs 0.005 qvs (71) Where: Vs is the system volume, l qvs is the system flow rate, l/min Another method is the introduction of a concentration step change at the beginning of the sampling line by switching from zero to span gas. If for a correctly calibrated analyzer after an adequate period of time the reading is ≤ 99 per cent compared to the introduced concentration, this points to a leakage problem that shall be corrected.
Response time check of the analytical system
The system settings for the response time evaluation shall be exactly the same as during measurement of the test run (i.e. pressure, flow rates, filter settings on the analyzers and all other response time influences). The response time determination shall be done with gas switching directly at the inlet of the sample probe. The gas switching shall be done in less than 0.1 second. The gases used for the test shall cause a concentration change of at least 60 per cent full scale (FS). The concentration trace of each single gas component shall be recorded. The response time is defined to be the difference in time between the gas switching and the appropriate change of the recorded concentration. The system response time (t90) consists of the delay time to the measuring
Annex 4
detector and the rise time of the detector. The delay time is defined as the time from the change (t0) until the response is 10 per cent of the final reading (t10). The rise time is defined as the time between 10 per cent and 90 per cent response of the final reading (t90 – t10). For time alignment of the analyzer and exhaust flow signals, the transformation time is defined as the time from the change (t0) until the response is 50 per cent of the final reading (t50). The system response time shall be 10 s with a rise time of 2.5 seconds in accordance with paragraph 9.3.1.7. for all limited components (CO, NOx, HC or NMHC) and all ranges used. When using a NMC for the measurement of NMHC, the system response time may exceed 10 seconds.
Efficiency test of NOx converter
The efficiency of the converter used for the conversion of NO 2 into NO is tested as given in paragraphs 9.3.6.1. to 9.3.6.8. (see Figure 8).
Test setup
Using the test setup as schematically shown in Figure 8 and the procedure below, the efficiency of the converter shall be tested by means of an ozonator.
Calibration
The CLD and the HCLD shall be calibrated in the most common operating range following the manufacturer's specifications using zero and span gas (the NO content of which shall amount to about 80 per cent of the operating range and the NO2 concentration of the gas mixture to less than 5 per cent of the NO concentration). The NOx analyzer shall be in the NO mode so that the span gas does not pass through the converter. The indicated concentration has to be recorded.
Calculation
The per cent efficiency of the converter shall be calculated as follows:
ab E NOx 1 100 cd (72) Where: a is the NOx concentration according to paragraph 9.3.6.6. b is the NOx concentration according to paragraph 9.3.6.7. c is the NO concentration according to paragraph 9.3.6.4. d is the NO concentration according to paragraph 9.3.6.5.
Adding of oxygen
Via a T-fitting, oxygen or zero air shall be added continuously to the gas flow until the concentration indicated is about 20 per cent less than the indicated calibration concentration given in paragraph 9.3.6.2. (the analyzer is in the NO mode). The indicated concentration (c) shall be recorded. The ozonator is kept deactivated throughout the process.
Activation of the ozonator
The ozonator shall be activated to generate enough ozone to bring the NO concentration down to about 20 per cent (minimum 10 per cent) of the calibration concentration given in paragraph 9.3.6.2. The indicated concentration (d) shall be recorded (the analyzer is in the NO mode).
NOx mode
The NO analyzer shall be switched to the NO x mode so that the gas mixture (consisting of NO, NO2, O2 and N2) now passes through the converter. The indicated concentration (a) shall be recorded (the analyzer is in the NOx mode).
Deactivation of the ozonator
The ozonator is now deactivated. The mixture of gases described in paragraph 9.3.6.6. passes through the converter into the detector. The indicated concentration (b) shall be recorded (the analyzer is in the NOx mode).
NO mode
Switched to NO mode with the ozonator deactivated, the flow of oxygen or synthetic air shall be shut off. The NOx reading of the analyzer shall not deviate by more than ±5 per cent from the value measured according to paragraph 9.3.6.2. (the analyzer is in the NO mode).
Test interval
The efficiency of the converter shall be tested at least once per month.
Annex 4
Efficiency requirement
The efficiency of the converter ENOx shall not be less than 95 per cent. If, with the analyzer in the most common range, the ozonator cannot give a reduction from 80 per cent to 20 per cent according to paragraph 9.3.6.5., the highest range which will give the reduction shall be used.
Adjustment of the FID
Optimization of the detector response
The FID shall be adjusted as specified by the instrument manufacturer. A propane in air span gas shall be used to optimize the response on the most common operating range. With the fuel and airflow rates set at the manufacturer's recommendations, a 350 ± 75 ppm C span gas shall be introduced to the analyzer. The response at a given fuel flow shall be determined from the difference between the span gas response and the zero gas response. The fuel flow shall be incrementally adjusted above and below the manufacturer's specification. The span and zero response at these fuel flows shall be recorded. The difference between the span and zero response shall be plotted and the fuel flow adjusted to the rich side of the curve. This is the initial flow rate setting which may need further optimization depending on the results of the hydrocarbon response factors and the oxygen interference check according to paragraphs 9.3.7.2. and 9.3.7.3. If the oxygen interference or the hydrocarbon response factors do not meet the following specifications, the airflow shall be incrementally adjusted above and below the manufacturer's specifications, repeating paragraphs 9.3.7.2. and 9.3.7.3. for each flow. The optimization may optionally be conducted using the procedures outlined in SAE paper No. 770141.
Hydrocarbon response factors
A linearity verification of the analyzer shall be performed using propane in air and purified synthetic air according to paragraph 9.2.1.3. Response factors shall be determined when introducing an analyzer into service and after major service intervals. The response factor (rh) for a particular hydrocarbon species is the ratio of the FID C1 reading to the gas concentration in the cylinder expressed by ppm C1. The concentration of the test gas shall be at a level to give a response of approximately 80 per cent of full scale. The concentration shall be known to an accuracy of ±2 per cent in reference to a gravimetric standard expressed in volume. In addition, the gas cylinder shall be preconditioned for 24 hours at a temperature of 298 K ± 5 K (25 °C ± 5 °C). The test gases to be used and the relative response factor ranges are as follows:
(a) Methane and purified synthetic air 1.00 rh 1.15;
(b) Propylene and purified synthetic air 0.90 rh 1.1;
(c) Toluene and purified synthetic air 0.90 rh 1.1.
These values are relative to a rh of 1 for propane and purified synthetic air.
Oxygen interference check
For raw exhaust gas analyzers only, the oxygen interference check shall be performed when introducing an analyzer into service and after major service intervals. A measuring range shall be chosen where the oxygen interference check gases will fall in the upper 50 per cent. The test shall be conducted with the oven temperature set as required. Oxygen interference check gas specifications are found in paragraph 9.3.3.4.
(a) The analyzer shall be set at zero;
(b) The analyzer shall be spanned with the 0 per cent oxygen blend for positive ignition engines. Compression ignition engine instruments shall be spanned with the 21 per cent oxygen blend;
(c) The zero response shall be rechecked. If it has changed by more than 0.5 per cent of full scale, steps (a) and (b) of this paragraph shall be repeated;
(d) The 5 per cent and 10 per cent oxygen interference check gases shall be introduced;
(e) The zero response shall be rechecked. If it has changed by more than 1 per cent of full scale, the test shall be repeated;
(f) The oxygen interference EO2 shall be calculated for each mixture in step (d) as follows:
EO2 = (cref,d - c) 100 / cref,d (73)
With the analyzer response being
c ref, b c FS,b c m, d c= (74) c m, b c FS,d Where: cref,b is the reference HC concentration in step (b), ppm C cref,d is the reference HC concentration in step (d), ppm C cFS,b is the full scale HC concentration in step (b), ppm C cFS,d is the full scale HC concentration in step (d), ppm C cm,b is the measured HC concentration in step (b), ppm C cm,d is the measured HC concentration in step (d), ppm C
(g) The oxygen interference EO2 shall be less than 1.5 per cent for all required oxygen interference check gases prior to testing;
(h) If the oxygen interference EO2 is greater than 1.5 per cent, corrective action may be taken by incrementally adjusting the airflow above and below the manufacturer's specifications, the fuel flow and the sample flow;
Annex 4
(i) The oxygen interference shall be repeated for each new setting.
Efficiency of the non-methane cutter (NMC)
The NMC is used for the removal of the non-methane hydrocarbons from the sample gas by oxidizing all hydrocarbons except methane. Ideally, the conversion for methane is 0 per cent, and for the other hydrocarbons represented by ethane is 100 per cent. For the accurate measurement of NMHC, the two efficiencies shall be determined and used for the calculation of the NMHC emission mass flow rate (see paragraph 8.6.2.).
Methane Efficiency
Methane calibration gas shall be flown through the FID with and without bypassing the NMC and the two concentrations recorded. The efficiency shall be determined as follows:
c HC(w/NMC) EM 1 (75) c HC(w/o NMC)
Where: cHC(w/NMC) is the HC concentration with CH4 flowing through the NMC, ppm C cHC(w/o NMC) is the HC concentration with CH4 bypassing the NMC, ppm C
Ethane Efficiency
Ethane calibration gas shall be flown through the FID with and without bypassing the NMC and the two concentrations recorded. The efficiency shall be determined as follows:
cHC(w/NMC) EE 1 c HC(w/o NMC) (76) Where: cHC(w/NMC) is the HC concentration with C2H6 flowing through the NMC, ppm C cHC(w/o NMC) is the HC concentration with C2H6 bypassing the NMC, ppm C
Interference effects
Other gases than the one being analyzed can interfere with the reading in several ways. Positive interference occurs in NDIR instruments where the interfering gas gives the same effect as the gas being measured, but to a lesser degree. Negative interference occurs in NDIR instruments by the interfering gas broadening the absorption band of the measured gas, and in CLD instruments by the interfering gas quenching the reaction. The interference checks in paragraphs 9.3.9.1. and 9.3.9.3. shall be performed prior to an analyzer's initial use and after major service intervals.
CO analyzer interference check
Water and CO2 can interfere with the CO analyzer performance. Therefore, a CO2 span gas having a concentration of 80 to 100 per cent of full scale of the maximum operating range used during testing shall be bubbled through water at room temperature and the analyzer response recorded. The analyzer response shall not be more than 2 per cent of the mean CO concentration expected during testing. Interference procedures for CO2 and H2O may also be run separately. If the CO2 and H2O levels used are higher than the maximum levels expected during testing, each observed interference value shall be scaled down by multiplying the observed interference by the ratio of the maximum expected concentration value to the actual value used during this procedure. Separate interference procedures concentrations of H2O that are lower than the maximum levels expected during testing may be run, but the observed H 2O interference shall be scaled up by multiplying the observed interference by the ratio of the maximum expected H2O concentration value to the actual value used during this procedure. The sum of the two scaled interference values shall meet the tolerance specified in this paragraph.
NOx analyzer quench checks for CLD analyzer
The two gases of concern for CLD (and HCLD) analyzers are CO 2 and water vapour. Quench responses to these gases are proportional to their concentrations, and therefore require test techniques to determine the quench at the highest expected concentrations experienced during testing. If the CLD analyzer uses quench compensation algorithms that utilize H2O and/or CO2 measurement instruments, quench shall be evaluated with these instruments active and with the compensation algorithms applied.
CO2 quench check
A CO2 span gas having a concentration of 80 to 100 per cent of full scale of the maximum operating range shall be passed through the NDIR analyzer and the CO2 value recorded as A. It shall then be diluted approximately 50 per cent with NO span gas and passed through the NDIR and CLD, with the CO 2 and NO values recorded as B and C, respectively. The CO2 shall then be shut off and only the NO span gas be passed through the (H)CLD and the NO value recorded as D. The per cent quench shall be calculated as follows:
C A E CO2 1 100 D A D B (77) Where: A is the undiluted CO2 concentration measured with NDIR, per cent B is the diluted CO2 concentration measured with NDIR, per cent C is the diluted NO concentration measured with (H)CLD, ppm D is the undiluted NO concentration measured with (H)CLD, ppm
Annex 4
Alternative methods of diluting and quantifying of CO 2 and NO span gas values such as dynamic mixing/blending are permitted with the approval of the Type Approval Authority.
Water quench check
This check applies to wet gas concentration measurements only. Calculation of water quench shall consider dilution of the NO span gas with water vapour and scaling of water vapour concentration of the mixture to that expected during testing. A NO span gas having a concentration of 80 per cent to 100 per cent of full scale of the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO span gas shall then be bubbled through water at room temperature and passed through the (H)CLD and the NO value recorded as C. The water temperature shall be determined and recorded as F. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in per cent) of the mixture shall be calculated as follows:
H = 100 x (G / pb) (78) and recorded as H. The expected diluted NO span gas (in water vapour) concentration shall be calculated as follows:
De = D x ( 1- H / 100 ) (79) and recorded as De. The maximum exhaust water vapour concentration (in per cent) expected during testing shall be estimated from the maximum CO2 concentration in the exhaust gas A as follows: Hm = α/2 x A (80) and recorded as Hm The per cent water quench shall be calculated as follows: EH2O = 100 x ( ( De - C ) / De) x (Hm / H) (81) Where: De is the expected diluted NO concentration, ppm C is the measured diluted NO concentration, ppm Hm is the maximum water vapour concentration, per cent H is the actual water vapour concentration, per cent
Maximum allowable quench
The combined CO2 and water quench shall not exceed 2 per cent of full scale.
NOx analyzer quench check for NDUV analyzer
Hydrocarbons and H2O can positively interfere with a NDUV analyzer by causing a response similar to NOx. If the NDUV analyzer uses compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously such measurements shall be conducted to test the algorithms during the analyzer interference verification.
Procedure
The NDUV analyzer shall be started, operated, zeroed, and spanned according to the instrument manufacturer's instructions. It is recommended to extract engine exhaust to perform this verification. A CLD shall be used to quantify NOx in the exhaust. The CLD response shall be used as the reference value. Also HC shall be measured in the exhaust with a FID analyzer. The FID response shall be used as the reference hydrocarbon value. Upstream of any sample dryer, if used during testing, the engine exhaust shall be introduced into the NDUV analyzer. Time shall be allowed for the analyzer response to stabilize. Stabilization time may include time to purge the transfer line and to account for analyzer response. While all analyzers measure the sample's concentration, 30 seconds of sampled data shall be recorded, and the arithmetic means for the three analyzers calculated. The CLD mean value shall be subtracted from the NDUV mean value. This difference shall be multiplied by the ratio of the expected mean HC concentration to the HC concentration measured during the verification, as follows:
c EHC/H2O c NOx,CLD c NOx,NDUV HC,e (82) cHC,m Where: cNOx,CLD is the measured NOx concentration with CLD, ppm cNOx,NDUV is the measured NOx concentration with NDUV, ppm cHC,e is the expected max. HC concentration, ppm cHC,m is the measured HC concentration, ppm
Maximum allowable quench
The combined HC and water quench shall not exceed 2 per cent of the NO x concentration expected during testing.
Sample dryer
A sample dryer removes water, which can otherwise interfere with a NO x measurement.
Sample dryer efficiency
For dry CLD analyzers, it shall be demonstrated that for the highest expected water vapour concentration Hm (see paragraph 9.3.9.2.2.), the sample dryer maintains CLD humidity at ≤ 5 g water/kg dry air (or about 0.008 per cent H2O), which is 100 per cent relative humidity at 3.9 °C and 101.3 kPa. This humidity specification is also equivalent to about 25 per cent relative humidity at 25 °C and 101.3 kPa. This may be demonstrated by measuring the temperature at the outlet of a thermal dehumidifier, or by measuring humidity at a point just upstream of the CLD. Humidity of the CLD exhaust might also be measured as long as the only flow into the CLD is the flow from the dehumidifier.
Annex 4
Sample dryer NO2 penetration
Liquid water remaining in an improperly designed sample dryer can remove NO2 from the sample. If a sample dryer is used in combination with an NDUV analyzer without an NO2/NO converter upstream, it could therefore remove NO2 from the sample prior NOx measurement. The sample dryer shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO 2.
Sampling for raw gaseous emissions, if applicable
The gaseous emissions sampling probes shall be fitted at least 0.5 m or three times the diameter of the exhaust pipe - whichever is the larger - upstream of the exit of the exhaust gas system but sufficiently close to the engine as to ensure an exhaust gas temperature of at least 343 K (70 °C) at the probe. In the case of a multi-cylinder engine with a branched exhaust manifold, the inlet of the probe shall be located sufficiently far downstream so as to ensure that the sample is representative of the average exhaust emissions from all cylinders. In multi-cylinder engines having distinct groups of manifolds, such as in a "Vee" engine configuration, it is recommended to combine the manifolds upstream of the sampling probe. If this is not practical, it is permissible to acquire a sample from the group with the highest CO 2 emission. For exhaust emission calculation the total exhaust mass flow shall be used. If the engine is equipped with an exhaust after-treatment system, the exhaust sample shall be taken downstream of the exhaust after-treatment system.
Sampling for dilute gaseous emissions, if applicable
The exhaust pipe between the engine and the full flow dilution system shall conform to the requirements laid down in Appendix 2 to this annex. The gaseous emissions sample probe(s) shall be installed in the dilution tunnel at a point where the diluent and exhaust gas are well mixed, and in close proximity to the particulates sampling probe. Sampling can generally be done in two ways:
(a) The emissions are sampled into a sampling bag over the cycle and measured after completion of the test; for HC, the sample bag shall be heated to 464 11 K (191 11°C), for NOx, the sample bag temperature shall be above the dew point temperature;
(b) The emissions are sampled continuously and integrated over the cycle. The background concentration shall be determined upstream of the dilution tunnel according to (a) or (b), and shall be subtracted from the emissions concentration according to paragraph 8.5.2.3.2.
Particulate measurement and sampling system
General specifications
To determine the mass of the particulates, a particulate dilution and sampling system, a particulate sampling filter, a microgram balance, and a temperature and humidity controlled weighing chamber, are required. The particulate
sampling system shall be designed to ensure a representative sample of the particulates proportional to the exhaust flow.
General requirements of the dilution system
The determination of the particulates requires dilution of the sample with filtered ambient air, synthetic air or nitrogen (the diluent). The dilution system shall be set as follows:
(a) Completely eliminate water condensation in the dilution and sampling systems;
(b) Maintain the temperature of the diluted exhaust gas between 315 K (42 °C) and 325 K (52 °C) within 20 cm upstream or downstream of the filter holder(s);
(c) The diluent temperature shall be between 293 K and 325 K (20 °C to 42 °C) in close proximity to the entrance into the dilution tunnel;
(d) The minimum dilution ratio shall be within the range of 5:1 to 7:1 and at least 2:1 for the primary dilution stage based on the maximum engine exhaust flow rate;
(e) For a partial flow dilution system, the residence time in the system from the point of diluent introduction to the filter holder(s) shall be between 0.5 and 5 seconds;
(f) For a full flow dilution system, the overall residence time in the system from the point of diluent introduction to the filter holder(s) shall be between 1 and 5 seconds, and the residence time in the secondary dilution system, if used, from the point of secondary diluent introduction to the filter holder(s) shall be at least 0.5 seconds. Dehumidifying the diluent before entering the dilution system is permitted, and especially useful if diluent humidity is high.
Particulate sampling
Partial flow dilution system
The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, but sufficiently distant as to not cause interference. Therefore, the installation provisions of paragraph 9.3.10. also apply to particulate sampling. The sampling line shall conform to the requirements laid down in Appendix 2 to this annex. In the case of a multi-cylinder engine with a branched exhaust manifold, the inlet of the probe shall be located sufficiently far downstream so as to ensure that the sample is representative of the average exhaust emissions from all cylinders. In multi-cylinder engines having distinct groups of manifolds, such as in a "Vee" engine configuration, it is recommended to combine the manifolds upstream of the sampling probe. If this is not practical, it is permissible to acquire a sample from the group with the highest particulate emission. For exhaust emission calculation the total exhaust mass flow of the manifold shall be used.
Annex 4
Full flow dilution system
The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, but sufficiently distant as to not cause interference, in the dilution tunnel. Therefore, the installation provisions of paragraph 9.3.11. also apply to particulate sampling. The sampling line shall conform to the requirements laid down in Appendix 2 to this annex.
Particulate sampling filters
The diluted exhaust shall be sampled by a filter that meets the requirements of paragraphs 9.4.4.1. to 9.4.4.3. during the test sequence.
Filter specification
All filter types shall have a 0.3 μm DOP (di-octylphthalate) or PAO (poly- alpha-olefin) collection efficiency of at least 99 per cent. The sample filter manufacturer’s measurements reflected in their product ratings may be used to show this requirement. The filter material shall be either:
(a) Fluorocarbon (PTFE) coated glass fibre, or
(b) Fluorocarbon (PTFE) membrane.
Filter size
The filter shall be circular with a nominal diameter of 47 mm (tolerance of 46.50 0.6 mm) and an exposed diameter (filter stain diameter) of at least 38 mm.
Filter face velocity
The face velocity through the filter shall be between 0.90 and 1.00 m/s with less than 5 per cent of the recorded flow values exceeding this range. If the total PM mass on the filter exceeds 400 µg, the filter face velocity may be reduced to 0.50 m/s. The face velocity shall be calculated as the volumetric flow rate of the sample at the pressure upstream of the filter and temperature of the filter face, divided by the filter's exposed area.
Weighing chamber and analytical balance specifications
The chamber (or room) environment shall be free of any ambient contaminants (such as dust, aerosol, or semi-volatile material) that could contaminate the particulate filters. The weighing room shall meet the required specifications for at least 60 min before weighing filters.
Weighing chamber conditions
The temperature of the chamber (or room) in which the particulate filters are conditioned and weighed shall be maintained to within 295 K ± 1 K (22 °C ± 1 °C) during all filter conditioning and weighing. The humidity shall be maintained to a dew point of 282.5 K ± 1 K (9.5 °C ± 1 °C). If the stabilization and weighing environments are separate, the temperature of the stabilization environment shall be maintained at a tolerance of 295 K ± 3 K (22 °C ± 3 °C), but the dew point requirement remains at 282.5 K ± 1 K (9.5 °C ± 1 °C). Humidity and ambient temperature shall be recorded.
Reference filter weighing
At least two unused reference filters shall be weighed within 12 hours of, but preferably at the same time as the sample filter weighing. They shall be the same material as the sample filters. Buoyancy correction shall be applied to the weighings. If the weight of any of the reference filters changes between sample filter weighings by more than 10 µg, all sample filters shall be discarded and the emissions test repeated. The reference filters shall be periodically replaced based on good engineering judgement, but at least once per year.
Analytical balance
The analytical balance used to determine the filter weight shall meet the linearity verification criterion of paragraph 9.2., Table 7. This implies a precision (standard deviation) of at least 2 µg and a resolution of at least 1 µg (1 digit = 1 µg). In order to ensure accurate filter weighing, it is recommended that the balance be installed as follows:
(a) Installed on a vibration-isolation platform to isolate it from external noise and vibration;
(b) Shielded from convective airflow with a static-dissipating draft shield that is electrically grounded.
Elimination of static electricity effects
The filter shall be neutralized prior to weighing, e.g. by a Polonium neutralizer or a device of similar effect. If a PTFE membrane filter is used, the static electricity shall be measured and is recommended to be within 2.0 V of neutral. Static electric charge shall be minimized in the balance environment. Possible methods are as follows:
(a) The balance shall be electrically grounded;
(b) Stainless steel tweezers shall be used if PM samples are handled manually;
(c) Tweezers shall be grounded with a grounding strap, or a grounding strap shall be provided for the operator such that the grounding strap shares a common ground with the balance. Grounding straps shall have an appropriate resistor to protect operators from accidental shock.
Additional specifications
All parts of the dilution system and the sampling system from the exhaust pipe up to the filter holder, which are in contact with raw and diluted exhaust gas, shall be designed to minimize deposition or alteration of the particulates. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects.
Annex 4
Calibration of the flow measurement instrumentation
Each flowmeter used in a particulate sampling and partial flow dilution system shall be subjected to the linearity verification, as described in paragraph 9.2.1., as often as necessary to fulfil the accuracy requirements of this Regulation. For the flow reference values, an accurate flowmeter traceable to international and/or national standards shall be used. For differential flow measurement calibration see paragraph 9.4.6.2.
Special requirements for the partial flow dilution system
The partial flow dilution system has to be designed to extract a proportional raw exhaust sample from the engine exhaust stream, thus responding to excursions in the exhaust stream flow rate. For this it is essential that the dilution ratio or the sampling ratio rd or rs be determined such that the accuracy requirements of paragraph 9.4.6.2. are fulfilled.
System response time
For the control of a partial flow dilution system, a fast system response is required. The transformation time for the system shall be determined by the procedure in paragraph 9.4.6.6. If the combined transformation time of the exhaust flow measurement (see paragraph 8.4.1.2.) and the partial flow system is ≤ 0.3 second, online control shall be used. If the transformation time exceeds 0.3 second, look ahead control based on a pre-recorded test run shall be used. In this case, the combined rise time shall be 1 second and the combined delay time 10 seconds. The total system response shall be designed as to ensure a representative sample of the particulates, qmp,i, proportional to the exhaust mass flow. To determine the proportionality, a regression analysis of qmp,i versus qmew,i shall be conducted on a minimum 5 Hz data acquisition rate, and the following criteria shall be met:
(a) The coefficient of determination r2 of the linear regression between qmp,i and qmew,i shall not be less than 0.95;
(b) The standard error of estimate of qmp,i on qmew,i shall not exceed 5 per cent of qmp maximum;
(c) qmp intercept of the regression line shall not exceed 2 per cent of qmp maximum. Look-ahead control is required if the combined transformation times of the particulate system, t50,P and of the exhaust mass flow signal, t50,F are > 0.3 second. In this case, a pre-test shall be run, and the exhaust mass flow signal of the pre-test be used for controlling the sample flow into the particulate system. A correct control of the partial dilution system is obtained, if the time trace of qmew,pre of the pre-test, which controls qmp, is shifted by a "look-ahead" time of t50,P + t50,F. For establishing the correlation between qmp,i and qmew,i the data taken during the actual test shall be used, with qmew,i time aligned by t50,F relative to qmp,i (no contribution from t50,P to the time alignment). That is, the time shift between qmew and qmp is the difference in their transformation times that were determined in paragraph 9.4.6.6.
Specifications for differential flow measurement
For partial flow dilution systems, the accuracy of the sample flow qmp is of special concern, if not measured directly, but determined by differential flow measurement: qmp = qmdew – qmdw (83) In this case, the maximum error of the difference shall be such that the accuracy of qmp is within 5 per cent when the dilution ratio is less than 15. It can be calculated by taking root-mean-square of the errors of each instrument. Acceptable accuracies of qmp can be obtained by either of the following methods:
(a) The absolute accuracies of qmdew and qmdw are 0.2 per cent which guarantees an accuracy of qmp of 5 per cent at a dilution ratio of 15. However, greater errors will occur at higher dilution ratios;
(b) Calibration of qmdw relative to qmdew is carried out such that the same accuracies for qmp as in (a) are obtained. For details see paragraph 9.4.6.3.;
(c) The accuracy of qmp is determined indirectly from the accuracy of the dilution ratio as determined by a tracer gas, e.g. CO2. Accuracies equivalent to method (a) for qmp are required;
(d) The absolute accuracy of qmdew and qmdw is within 2 per cent of full scale, the maximum error of the difference between qmdew and qmdw is within 0.2 per cent, and the linearity error is within 0.2 per cent of the highest qmdew observed during the test.
Calibration of differential flow measurement
The flowmeter or the flow measurement instrumentation shall be calibrated in one of the following procedures, such that the probe flow qmp into the tunnel shall fulfil the accuracy requirements of paragraph 9.4.6.2.:
(a) The flowmeter for qmdw shall be connected in series to the flowmeter for qmdew, the difference between the two flowmeters shall be calibrated for at least five set points with flow values equally spaced between the lowest qmdw value used during the test and the value of qmdew used during the test. The dilution tunnel may be bypassed;
(b) A calibrated flow device shall be connected in series to the flowmeter for qmdew and the accuracy shall be checked for the value used for the test. The calibrated flow device shall be connected in series to the flowmeter for qmdw, and the accuracy shall be checked for at least five settings corresponding to dilution ratio between 3 and 50, relative to qmdew used during the test;
(c) The transfer tube (TT) shall be disconnected from the exhaust, and a calibrated flow-measuring device with a suitable range to measure qmp shall be connected to the transfer tube. qmdew shall be set to the value used during the test, and qmdw shall be sequentially set to at least five values corresponding to dilution ratios between 3 and 50. Alternatively, a special calibration flow path may be provided, in which the tunnel is bypassed, but the total and diluent flow through the corresponding meters as in the actual test;
Annex 4
(d) A tracer gas shall be fed into the exhaust transfer tube TT. This tracer gas may be a component of the exhaust gas, like CO2 or NOx. After dilution in the tunnel the tracer gas component shall be measured. This shall be carried out for five dilution ratios between 3 and 50. The accuracy of the sample flow shall be determined from the dilution ratio rd: qmp = qmdew /rd (84) The accuracies of the gas analyzers shall be taken into account to guarantee the accuracy of qmp.
Carbon flow check
A carbon flow check using actual exhaust is strongly recommended for detecting measurement and control problems and verifying the proper operation of the partial flow system. The carbon flow check should be run at least each time a new engine is installed, or something significant is changed in the test cell configuration. The engine shall be operated at peak torque load and speed or any other steady state mode that produces 5 per cent or more of CO 2. The partial flow sampling system shall be operated with a dilution factor of about 15 to 1. If a carbon flow check is conducted, the procedure given in Appendix 4 shall be applied. The carbon flow rates shall be calculated according to equations 112 to 114 in Appendix 4 to this annex. All carbon flow rates should agree to within 3 per cent.
Pre-test check
A pre-test check shall be performed within 2 hours before the test run in the following way. The accuracy of the flowmeters shall be checked by the same method as used for calibration (see paragraph 9.4.6.2.) for at least two points, including flow values of qmdw that correspond to dilution ratios between 5 and 15 for the qmdew value used during the test. If it can be demonstrated by records of the calibration procedure under paragraph 9.4.6.2. that the flowmeter calibration is stable over a longer period of time, the pre-test check may be omitted.
Determination of the transformation time
The system settings for the transformation time evaluation shall be exactly the same as during measurement of the test run. The transformation time shall be determined by the following method. An independent reference flowmeter with a measurement range appropriate for the probe flow shall be put in series with and closely coupled to the probe. This flowmeter shall have a transformation time of less than 100 ms for the flow step size used in the response time measurement, with flow restriction sufficiently low as to not affect the dynamic performance of the partial flow dilution system, and consistent with good engineering practice. A step change shall be introduced to the exhaust flow (or airflow if exhaust flow is calculated) input of the partial flow dilution system, from a low flow to at least 90 per cent of maximum exhaust flow. The trigger for the step
change shall be the same one used to start the look-ahead control in actual testing. The exhaust flow step stimulus and the flowmeter response shall be recorded at a sample rate of at least 10 Hz. From this data, the transformation time shall be determined for the partial flow dilution system, which is the time from the initiation of the step stimulus to the 50 per cent point of the flowmeter response. In a similar manner, the transformation times of the qmp signal of the partial flow dilution system and of the qmew,i signal of the exhaust flowmeter shall be determined. These signals are used in the regression checks performed after each test (see paragraph 9.4.6.1.). The calculation shall be repeated for at least 5 rise and fall stimuli, and the results shall be averaged. The internal transformation time (< 100 ms) of the reference flowmeter shall be subtracted from this value. This is the "look- ahead" value of the partial flow dilution system, which shall be applied in accordance with paragraph 9.4.6.1.
Calibration of the CVS system
General
The CVS system shall be calibrated by using an accurate flowmeter and a restricting device. The flow through the system shall be measured at different restriction settings, and the control parameters of the system shall be measured and related to the flow. Various types of flowmeters may be used, e.g. calibrated venturi, calibrated laminar flowmeter, calibrated turbine meter.
Calibration of the positive displacement pump (PDP)
All the parameters related to the pump shall be simultaneously measured along with the parameters related to a calibration venturi which is connected in series with the pump. The calculated flow rate (in m3/s at pump inlet, absolute pressure and temperature) shall be plotted versus a correlation function which is the value of a specific combination of pump parameters. The linear equation which relates the pump flow and the correlation function shall be determined. If a CVS has a multiple speed drive, the calibration shall be performed for each range used. Temperature stability shall be maintained during calibration. Leaks in all the connections and ducting between the calibration venturi and the CVS pump shall be maintained lower than 0.3 per cent of the lowest flow point (highest restriction and lowest PDP speed point).
Data analysis
The airflow rate (qvCVS) at each restriction setting (minimum six settings) shall be calculated in standard m3/s from the flowmeter data using the manufacturer's prescribed method. The airflow rate shall then be converted to pump flow (V0) in m3/rev at absolute pump inlet temperature and pressure as follows: q vCVS T 101,3 V0 = (85) n 273 pp
Annex 4
Where: qvCVS is the airflow rate at standard conditions (101.3 kPa, 273 K), m3/s T is the temperature at pump inlet, K pp is the absolute pressure at pump inlet, kPa n is the pump speed, rev/s To account for the interaction of pressure variations at the pump and the pump slip rate, the correlation function (X0) between pump speed, pressure differential from pump inlet to pump outlet and absolute pump outlet pressure shall be calculated as follows:
1 pp X0 (86) n pp Where: p p is the pressure differential from pump inlet to pump outlet, kPa pp is the absolute outlet pressure at pump outlet, kPa A linear least-square fit shall be performed to generate the calibration equation as follows:
V0 D0 m X 0 (87)
D0 and m are the intercept and slope, respectively, describing the regression lines. For a CVS system with multiple speeds, the calibration curves generated for the different pump flow ranges shall be approximately parallel, and the intercept values (D0) shall increase as the pump flow range decreases. The calculated values from the equation shall be within ±0.5 per cent of the measured value of V0. Values of m will vary from one pump to another. Particulate influx over time will cause the pump slip to decrease, as reflected by lower values for m. Therefore, calibration shall be performed at pump start-up, after major maintenance, and if the total system verification indicates a change of the slip rate.
Calibration of the critical flow venturi (CFV)
Calibration of the CFV is based upon the flow equation for a critical venturi. Gas flow is a function of venturi inlet pressure and temperature. To determine the range of critical flow, Kv shall be plotted as a function of venturi inlet pressure. For critical (choked) flow, Kv will have a relatively constant value. As pressure decreases (vacuum increases), the venturi becomes unchoked and Kv decreases, which indicates that the CFV is operated outside the permissible range.
Data analysis
The airflow rate (qvCVS) at each restriction setting (minimum 8 settings) shall be calculated in standard m3/s from the flowmeter data using the manufacturer's prescribed method. The calibration coefficient shall be calculated from the calibration data for each setting as follows:
qvCVS T Kv (88) pp Where: qvCVS is the airflow rate at standard conditions (101.3 kPa, 273 K), m3/s T is the temperature at the venturi inlet, K pp is the absolute pressure at venturi inlet, kPa The average KV and the standard deviation shall be calculated. The standard deviation shall not exceed ±0.3 per cent of the average KV.
Calibration of the subsonic venturi (SSV)
Calibration of the SSV is based upon the flow equation for a subsonic venturi. Gas flow is a function of inlet pressure and temperature, pressure drop between the SSV inlet and throat, as shown in equation 53 (see paragraph 8.5.1.4.).
Data analysis
The airflow rate (QSSV) at each restriction setting (minimum 16 settings) shall be calculated in standard m3/s from the flowmeter data using the manufacturer's prescribed method. The discharge coefficient shall be calculated from the calibration data for each setting as follows:
QSSV Cd (89) 1 d V p p rp 1.4286 rp 1.7143 1 1.4286 T 1 rD rp
Where: QSSV is the airflow rate at standard conditions (101.3 kPa, 273 K), m3/s T is the temperature at the venturi inlet, K dV is the diameter of the SSV throat, m
rp is the ratio of the SSV throat to inlet absolute static pressure = 1 p pp
rD is the ratio of the SSV throat diameter, dV, to the inlet pipe inner diameter D To determine the range of subsonic flow, Cd shall be plotted as a function of Reynolds number Re, at the SSV throat. The Re at the SSV throat shall be calculated with the following equation:
Annex 4
QSSV Re A1 dV (90) With b T 1.5 ST (91) Where:
A1 is 25.55152 in SI units of 1 min mm m s m
QSSV is the airflow rate at standard conditions (101.3 kPa, 273 K), m3/s dV is the diameter of the SSV throat, m μ is the absolute or dynamic viscosity of the gas, kg/ms b is 1.458 x 106 (empirical constant), kg/ms K0.5 S is 110.4 (empirical constant), K Because QSSV is an input to the Re equation, the calculations shall be started with an initial guess for QSSV or Cd of the calibration venturi, and repeated until QSSV converges. The convergence method shall be accurate to 0.1 per cent of point or better. For a minimum of sixteen points in the region of subsonic flow, the calculated values of Cd from the resulting calibration curve fit equation shall be within ±0.5 per cent of the measured Cd for each calibration point.
Total system verification
The total accuracy of the CVS sampling system and analytical system shall be determined by introducing a known mass of a pollutant gas into the system while it is being operated in the normal manner. The pollutant is analyzed, and the mass calculated according to paragraph 8.5.2.3. except in the case of propane where a u factor of 0.000472 is used in place of 0.000480 for HC. Either of the following two techniques shall be used.
Metering with a critical flow orifice
A known quantity of pure gas (carbon monoxide or propane) shall be fed into the CVS system through a calibrated critical orifice. If the inlet pressure is high enough, the flow rate, which is adjusted by means of the critical flow orifice, is independent of the orifice outlet pressure (critical flow). The CVS system shall be operated as in a normal exhaust emission test for about 5 to 10 minutes. A gas sample shall be analyzed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated. The mass so determined shall be within ±3 per cent of the known mass of the gas injected.
Metering by means of a gravimetric technique
The mass of a small cylinder filled with carbon monoxide or propane shall be determined with a precision of ±0.01 g. For about 5 to 10 minutes, the CVS system shall be operated as in a normal exhaust emission test, while carbon
monoxide or propane is injected into the system. The quantity of pure gas discharged shall be determined by means of differential weighing. A gas sample shall be analyzed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated. The mass so determined shall be within ±3 per cent of the known mass of the gas injected.
10.Particle number measurement test procedure
Sampling
Particle number emissions shall be measured by continuous sampling from either a partial flow dilution system, as described in Appendix 2 to this annex, paragraph A.2.2.1. and A.2.2.2. or a full flow dilution system as described in Appendix 2 to this annex, paragraph A.2.2.3. and A.2.2.4.
Diluent filtration
Diluent used for both the primary and, where applicable, secondary dilution of the exhaust in the dilution system shall be passed through filters meeting the High-Efficiency Particulate Air (HEPA) filter requirements defined in Appendix 2 to this annex, paragraphs A.2.2.2. or A.2.2.4. The diluent may optionally be charcoal scrubbed before being passed to the HEPA filter to reduce and stabilize the hydrocarbon concentrations in the diluent. It is recommended that an additional coarse particle filter is situated before the HEPA filter and after the charcoal scrubber, if used.
Compensating for particle number sample flow – full flow dilution systems
To compensate for the mass flow extracted from the dilution system for particle number sampling the extracted mass flow (filtered) shall be returned to the dilution system. Alternatively, the total mass flow in the dilution system may be mathematically corrected for the particle number sample flow extracted. Where the total mass flow extracted from the dilution system for the sum of particle number sampling and particulate mass sampling is less than 0.5 per cent of the total dilute exhaust gas flow in the dilution tunnel
(med) this correction, or flow return, may be neglected.
Compensating for particle number sample flow – partial flow dilution systems
For partial flow dilution systems the mass flow extracted from the dilution system for particle number sampling shall be accounted for in controlling the proportionality of sampling. This shall be achieved either by feeding the particle number sample flow back into the dilution system upstream of the flow measuring device or by mathematical correction as outlined in paragraph 10.3.2. In the case of total sampling type partial flow dilution systems, the mass flow extracted for particle number sampling shall also be corrected for in the particulate mass calculation as outlined in paragraph 10.3.3.
The instantaneous exhaust gas flow rate into the dilution system (qmp), used for controlling the proportionality of sampling, shall be corrected according to one of the following methods:
Annex 4
(a) In the case where the extracted particle number sample flow is discarded, equation 83 in paragraph 9.4.6.2. shall be replaced by the following:
qmp qmdew qmdw qex (92)
Where: qmp = sample flow of exhaust gas into partial flow dilution system, kg/s, qmdew = diluted exhaust mass flow rate, kg/s, qmdw = dilution air mass flow rate, kg/s, qex = particle number sample mass flow rate, kg/s. The qex signal sent to the partial flow system controller shall be accurate to within 0.1 per cent of qmdew at all times and should be sent with frequency of at least 1 Hz.
(b) In the case where the extracted particle number sample flow is fully or partially discarded, but an equivalent flow is fed back to the dilution system upstream of the flow measurement device, equation 83 in paragraph 9.4.6.2. shall be replaced by the following:
qmp qmdew qmdw qex qsw (93)
Where: qmp = sample flow of exhaust gas into partial flow dilution system, kg/s, qmdew = diluted exhaust mass flow rate, kg/s, qmdw = dilution air mass flow rate, kg/s, qex = particle number sample mass flow rate, kg/s, qsw = mass flow rate fed back into dilution tunnel to compensate for particle number sample extraction, kg/s. The difference between qex and qsw sent to the partial flow system controller shall be accurate to within 0.1 per cent of qmdew at all times. The signal (or signals) should be sent with frequency of at least 1 Hz.
Correction of PM measurement
When a particle number sample flow is extracted from a total sampling partial flow dilution system, the mass of particulates (mPM) calculated in paragraph 8.4.3.2.1. or 8.4.3.2.2. shall be corrected as follows to account for the flow extracted. This correction is required even where filtered extracted flow is fed back into the partial flow dilution systems.
msed mPM ,corr mPM (94) (msed mex )
Where: mPM,corr = mass of particulates corrected for extraction of particle number sample flow, g/test, mPM = mass of particulates determined according to paragraph 8.4.3.2.1. or 8.4.3.2.2., g/test, msed = total mass of diluted exhaust gas passing through the dilution tunnel, kg, mex = total mass of diluted exhaust gas extracted from the dilution tunnel for particle number sampling, kg.
Proportionality of partial flow dilution sampling
For particle number measurement, exhaust mass flow rate, determined according to any of the methods described in paragraphs 8.4.1.3. to 8.4.1.7., is used for controlling the partial flow dilution system to take a sample proportional to the exhaust mass flow rate. The quality of proportionality shall be checked by applying a regression analysis between sample and exhaust flow in accordance with paragraph 9.4.6.1.
Determination of particle numbers
Time alignment
For partial flow dilution systems residence time in the particle number sampling and measurement system shall be accounted for by time aligning the particle number signal with the test cycle and the exhaust gas mass flow rate according to the procedure in paragraph 8.4.2.2. The transformation time of the particle number sampling and measurement system shall be determined according to paragraph A.8.1.3.7. of Appendix 8 to this annex.
Determination of particle numbers with a partial flow dilution system
Where particle numbers are sampled using a partial flow dilution system according to the procedures set out in paragraph 8.4., the number of particles emitted over the test cycle shall be calculated by means of the following equation: medf N . k .cs . f r .106 (95) 1.293
Where: N = number of particles emitted over the test cycle, medf = mass of equivalent diluted exhaust gas over the cycle, determined according to paragraph 8.4.3.2.2., kg/test, k = calibration factor to correct the particle number counter measurements to the level of the reference instrument where this is not applied internally within the particle number counter. Where the calibration factor is applied internally within the particle number counter, a value of 1 shall be used for k in the above equation,
Annex 4
cs = average concentration of particles from the diluted exhaust gas corrected to standard conditions (273.2 K and 101.33 kPa), particles per cubic centimetre,
fr = mean particle concentration reduction factor of the volatile particle remover specific to the dilution settings used for the test.
cs shall be calculated from the following equation:
c i n
c s i 1 s ,i (96) n Where: cs,i = a discrete measurement of particle concentration in the diluted gas exhaust from the particle counter, corrected for coincidence and to standard conditions (273.2 K and 101.33 kPa), particles per cubic centimetre, n = number of particle concentration measurements taken over the duration of the test.
Determination of particle numbers with a full flow dilution system
Where particle numbers are sampled using a full flow dilution system according to the procedures set out in paragraph 8.5., the number of particles emitted over the test cycle shall be calculated by means of the following equation: medf N . k .cs . f r .106 (97) 1.293
Where: N = number of particles emitted over the test cycle, med = total diluted exhaust gas flow over the cycle calculated according to any one of the methods described in paragraphs 8.5.1.2. to 8.5.1.4., kg/test, k = calibration factor to correct the particle number counter measurements to the level of the reference instrument where this is not applied internally within the particle number counter. Where the calibration factor is applied internally within the particle number counter, a value of 1 shall be used for k in the above equation,
cs = average corrected concentration of particles from the diluted exhaust gas corrected to standard conditions (273.2 K and 101.33 kPa), particles per cubic centimetre,
fr = mean particle concentration reduction factor of the volatile particle remover specific to the dilution settings used for the test.
cs shall be calculated from the following equation:
c i n
c i 1 s , i (98) n Where: cs,i = a discrete measurement of particle concentration in the diluted gas exhaust from the particle counter, corrected for coincidence and to standard conditions (273.2 K and 101.33 kPa), particles per cubic centimetre, n = number of particle concentration measurements taken over the duration of the test.
Test result
Calculation of the specific emissions
For each individual WHSC, hot WHTC and cold WHTC the specific emissions in number of particles/kWh shall be calculated as follows: N e (99) Wact Where: e = is the number of particles emitted per kWh,
Wact = is the actual cycle work according to paragraph 7.8.6., in kWh.
Exhaust after-treatment systems with periodic regeneration
For engines equipped with periodically regenerating after-treatment systems, the general provisions of paragraph 6.6.2. apply. The WHTC hot start emissions shall be weighted according to equation 5 where e is the average number of particles/kWh without regeneration, and e r is the average number of particles/kWh with regeneration. The calculation of the regeneration adjustment factors shall be done according to equations 6, 6a, 7 or 8, as appropriate.
Weighted average WHTC test result
For the WHTC, the final test result shall be a weighted average from cold start and hot start (including periodic regeneration where relevant) tests calculated using one of the following equations:
(a) In the case of multiplicative regeneration adjustment, or engines without periodically regenerating after-treatment
Annex 4
(0.14 Ncold ) (0.86 N hot ) e kr (100) (0.14 W ) ( 0.86 W ) act , cold act.hot
(b) In the case of additive regeneration adjustment
(0.14 N cold ) (0.86 N hot ) e k r (101) (0.14 Wact,cold ) (0.86 Wact.hot ) Where: Ncold = is the total number of particles emitted over the WHTC cold test cycle, Nhot = is the total number of particles emitted over the WHTC hot test cycle, Wact,cold = is the actual cycle work over the WHTC cold test cycle according to paragraph 7.8.6., in kWh, Wact, hot = is the actual cycle work over the WHTC hot test cycle according to paragraph 7.8.6., in kWh, kr = is the regeneration adjustment, according to paragraph 6.6.2., or in the case of engines without periodically regenerating after-treatment kr = 1
Rounding of final results
The final WHSC and weighted average WHTC test results shall be rounded in one step to three significant figures in accordance with ASTM E 29–06B. No rounding of intermediate values leading to the final brake specific emission result is permissible.
Determination of particle number background
At the engine manufacturer’s request, dilution tunnel background particle number concentrations may be sampled, prior to or after the test, from a point downstream of the particle and hydrocarbon filters into the particle number measurement system, to determine the tunnel background particle concentrations.
Subtraction of particle number tunnel background concentrations shall not be allowed for type approval, but may be used at the manufacturer’s request, with the prior approval of the Type Approval Authority , for conformity of production testing, if it can be demonstrated that tunnel background contribution is significant, which can then be subtracted from the values measured in the diluted exhaust.
Annex 4 - Appendix 1 — WHTC engine dynamometer schedule
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1 0.0 0.0 47 0.0 0.0 93 32.8 32.7 2 0.0 0.0 48 0.0 0.0 94 33.7 32.5 3 0.0 0.0 49 0.0 0.0 95 34.4 29.5 4 0.0 0.0 50 0.0 13.1 96 34.3 26.5 5 0.0 0.0 51 13.1 30.1 97 34.4 24.7 6 0.0 0.0 52 26.3 25.5 98 35.0 24.9 7 1.5 8.9 53 35.0 32.2 99 35.6 25.2 8 15.8 30.9 54 41.7 14.3 100 36.1 24.8 9 27.4 1.3 55 42.2 0.0 101 36.3 24.0 10 32.6 0.7 56 42.8 11.6 102 36.2 23.6 11 34.8 1.2 57 51.0 20.9 103 36.2 23.5 12 36.2 7.4 58 60.0 9.6 104 36.8 22.7 13 37.1 6.2 59 49.4 0.0 105 37.2 20.9 14 37.9 10.2 60 38.9 16.6 106 37.0 19.2 15 39.6 12.3 61 43.4 30.8 107 36.3 18.4 16 42.3 12.5 62 49.4 14.2 108 35.4 17.6 17 45.3 12.6 63 40.5 0.0 109 35.2 14.9 18 48.6 6.0 64 31.5 43.5 110 35.4 9.9 19 40.8 0.0 65 36.6 78.2 111 35.5 4.3 20 33.0 16.3 66 40.8 67.6 112 35.2 6.6 21 42.5 27.4 67 44.7 59.1 113 34.9 10.0 22 49.3 26.7 68 48.3 52.0 114 34.7 25.1 23 54.0 18.0 69 51.9 63.8 115 34.4 29.3 24 57.1 12.9 70 54.7 27.9 116 34.5 20.7 25 58.9 8.6 71 55.3 18.3 117 35.2 16.6 26 59.3 6.0 72 55.1 16.3 118 35.8 16.2 27 59.0 4.9 73 54.8 11.1 119 35.6 20.3 28 57.9 m 74 54.7 11.5 120 35.3 22.5 29 55.7 m 75 54.8 17.5 121 35.3 23.4 30 52.1 m 76 55.6 18.0 122 34.7 11.9 31 46.4 m 77 57.0 14.1 123 45.5 0.0 32 38.6 m 78 58.1 7.0 124 56.3 m 33 29.0 m 79 43.3 0.0 125 46.2 m 34 20.8 m 80 28.5 25.0 126 50.1 0.0 35 16.9 m 81 30.4 47.8 127 54.0 m 36 16.9 42.5 82 32.1 39.2 128 40.5 m 37 18.8 38.4 83 32.7 39.3 129 27.0 m 38 20.7 32.9 84 32.4 17.3 130 13.5 m 39 21.0 0.0 85 31.6 11.4 131 0.0 0.0 40 19.1 0.0 86 31.1 10.2 132 0.0 0.0 41 13.7 0.0 87 31.1 19.5 133 0.0 0.0 42 2.2 0.0 88 31.4 22.5 134 0.0 0.0 43 0.0 0.0 89 31.6 22.9 135 0.0 0.0 44 0.0 0.0 90 31.6 24.3 136 0.0 0.0 45 0.0 0.0 91 31.9 26.9 137 0.0 0.0 46 0.0 0.0 92 32.4 30.6 138 0.0 0.0
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 139 0.0 0.0 189 0.0 5.9 239 0.0 0.0 140 0.0 0.0 190 0.0 0.0 240 0.0 0.0 141 0.0 0.0 191 0.0 0.0 241 0.0 0.0 142 0.0 4.9 192 0.0 0.0 242 0.0 0.0 143 0.0 7.3 193 0.0 0.0 243 0.0 0.0 144 4.4 28.7 194 0.0 0.0 244 0.0 0.0 145 11.1 26.4 195 0.0 0.0 245 0.0 0.0 146 15.0 9.4 196 0.0 0.0 246 0.0 0.0 147 15.9 0.0 197 0.0 0.0 247 0.0 0.0 148 15.3 0.0 198 0.0 0.0 248 0.0 0.0 149 14.2 0.0 199 0.0 0.0 249 0.0 0.0 150 13.2 0.0 200 0.0 0.0 250 0.0 0.0 151 11.6 0.0 201 0.0 0.0 251 0.0 0.0 152 8.4 0.0 202 0.0 0.0 252 0.0 0.0 153 5.4 0.0 203 0.0 0.0 253 0.0 31.6 154 4.3 5.6 204 0.0 0.0 254 9.4 13.6 155 5.8 24.4 205 0.0 0.0 255 22.2 16.9 156 9.7 20.7 206 0.0 0.0 256 33.0 53.5 157 13.6 21.1 207 0.0 0.0 257 43.7 22.1 158 15.6 21.5 208 0.0 0.0 258 39.8 0.0 159 16.5 21.9 209 0.0 0.0 259 36.0 45.7 160 18.0 22.3 210 0.0 0.0 260 47.6 75.9 161 21.1 46.9 211 0.0 0.0 261 61.2 70.4 162 25.2 33.6 212 0.0 0.0 262 72.3 70.4 163 28.1 16.6 213 0.0 0.0 263 76.0 m 164 28.8 7.0 214 0.0 0.0 264 74.3 m 165 27.5 5.0 215 0.0 0.0 265 68.5 m 166 23.1 3.0 216 0.0 0.0 266 61.0 m 167 16.9 1.9 217 0.0 0.0 267 56.0 m 168 12.2 2.6 218 0.0 0.0 268 54.0 m 169 9.9 3.2 219 0.0 0.0 269 53.0 m 170 9.1 4.0 220 0.0 0.0 270 50.8 m 171 8.8 3.8 221 0.0 0.0 271 46.8 m 172 8.5 12.2 222 0.0 0.0 272 41.7 m 173 8.2 29.4 223 0.0 0.0 273 35.9 m 174 9.6 20.1 224 0.0 0.0 274 29.2 m 175 14.7 16.3 225 0.0 0.0 275 20.7 m 176 24.5 8.7 226 0.0 0.0 276 10.1 m 177 39.4 3.3 227 0.0 0.0 277 0.0 m 178 39.0 2.9 228 0.0 0.0 278 0.0 0.0 179 38.5 5.9 229 0.0 0.0 279 0.0 0.0 180 42.4 8.0 230 0.0 0.0 280 0.0 0.0 181 38.2 6.0 231 0.0 0.0 281 0.0 0.0 182 41.4 3.8 232 0.0 0.0 282 0.0 0.0 183 44.6 5.4 233 0.0 0.0 283 0.0 0.0 184 38.8 8.2 234 0.0 0.0 284 0.0 0.0 185 37.5 8.9 235 0.0 0.0 285 0.0 0.0 186 35.4 7.3 236 0.0 0.0 286 0.0 0.0 187 28.4 7.0 237 0.0 0.0 287 0.0 0.0 188 14.8 7.0 238 0.0 0.0 288 0.0 0.0
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 289 0.0 0.0 339 0.0 0.0 389 25.2 14.7 290 0.0 0.0 340 0.0 0.0 390 28.6 28.4 291 0.0 0.0 341 0.0 0.0 391 35.5 65.0 292 0.0 0.0 342 0.0 0.0 392 43.8 75.3 293 0.0 0.0 343 0.0 0.0 393 51.2 34.2 294 0.0 0.0 344 0.0 0.0 394 40.7 0.0 295 0.0 0.0 345 0.0 0.0 395 30.3 45.4 296 0.0 0.0 346 0.0 0.0 396 34.2 83.1 297 0.0 0.0 347 0.0 0.0 397 37.6 85.3 298 0.0 0.0 348 0.0 0.0 398 40.8 87.5 299 0.0 0.0 349 0.0 0.0 399 44.8 89.7 300 0.0 0.0 350 0.0 0.0 400 50.6 91.9 301 0.0 0.0 351 0.0 0.0 401 57.6 94.1 302 0.0 0.0 352 0.0 0.0 402 64.6 44.6 303 0.0 0.0 353 0.0 0.0 403 51.6 0.0 304 0.0 0.0 354 0.0 0.5 404 38.7 37.4 305 0.0 0.0 355 0.0 4.9 405 42.4 70.3 306 0.0 0.0 356 9.2 61.3 406 46.5 89.1 307 0.0 0.0 357 22.4 40.4 407 50.6 93.9 308 0.0 0.0 358 36.5 50.1 408 53.8 33.0 309 0.0 0.0 359 47.7 21.0 409 55.5 20.3 310 0.0 0.0 360 38.8 0.0 410 55.8 5.2 311 0.0 0.0 361 30.0 37.0 411 55.4 m 312 0.0 0.0 362 37.0 63.6 412 54.4 m 313 0.0 0.0 363 45.5 90.8 413 53.1 m 314 0.0 0.0 364 54.5 40.9 414 51.8 m 315 0.0 0.0 365 45.9 0.0 415 50.3 m 316 0.0 0.0 366 37.2 47.5 416 48.4 m 317 0.0 0.0 367 44.5 84.4 417 45.9 m 318 0.0 0.0 368 51.7 32.4 418 43.1 m 319 0.0 0.0 369 58.1 15.2 419 40.1 m 320 0.0 0.0 370 45.9 0.0 420 37.4 m 321 0.0 0.0 371 33.6 35.8 421 35.1 m 322 0.0 0.0 372 36.9 67.0 422 32.8 m 323 0.0 0.0 373 40.2 84.7 423 45.3 0.0 324 4.5 41.0 374 43.4 84.3 424 57.8 m 325 17.2 38.9 375 45.7 84.3 425 50.6 m 326 30.1 36.8 376 46.5 m 426 41.6 m 327 41.0 34.7 377 46.1 m 427 47.9 0.0 328 50.0 32.6 378 43.9 m 428 54.2 m 329 51.4 0.1 379 39.3 m 429 48.1 m 330 47.8 m 380 47.0 m 430 47.0 31.3 331 40.2 m 381 54.6 m 431 49.0 38.3 332 32.0 m 382 62.0 m 432 52.0 40.1 333 24.4 m 383 52.0 m 433 53.3 14.5 334 16.8 m 384 43.0 m 434 52.6 0.8 335 8.1 m 385 33.9 m 435 49.8 m 336 0.0 m 386 28.4 m 436 51.0 18.6 337 0.0 0.0 387 25.5 m 437 56.9 38.9 338 0.0 0.0 388 24.6 11.0 438 67.2 45.0
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 439 78.6 21.5 489 45.5 m 539 56.7 m 440 65.5 0.0 490 40.4 m 540 46.9 m 441 52.4 31.3 491 49.7 0.0 541 37.5 m 442 56.4 60.1 492 59.0 m 542 30.3 m 443 59.7 29.2 493 48.9 m 543 27.3 32.3 444 45.1 0.0 494 40.0 m 544 30.8 60.3 445 30.6 4.2 495 33.5 m 545 41.2 62.3 446 30.9 8.4 496 30.0 m 546 36.0 0.0 447 30.5 4.3 497 29.1 12.0 547 30.8 32.3 448 44.6 0.0 498 29.3 40.4 548 33.9 60.3 449 58.8 m 499 30.4 29.3 549 34.6 38.4 450 55.1 m 500 32.2 15.4 550 37.0 16.6 451 50.6 m 501 33.9 15.8 551 42.7 62.3 452 45.3 m 502 35.3 14.9 552 50.4 28.1 453 39.3 m 503 36.4 15.1 553 40.1 0.0 454 49.1 0.0 504 38.0 15.3 554 29.9 8.0 455 58.8 m 505 40.3 50.9 555 32.5 15.0 456 50.7 m 506 43.0 39.7 556 34.6 63.1 457 42.4 m 507 45.5 20.6 557 36.7 58.0 458 44.1 0.0 508 47.3 20.6 558 39.4 52.9 459 45.7 m 509 48.8 22.1 559 42.8 47.8 460 32.5 m 510 50.1 22.1 560 46.8 42.7 461 20.7 m 511 51.4 42.4 561 50.7 27.5 462 10.0 m 512 52.5 31.9 562 53.4 20.7 463 0.0 0.0 513 53.7 21.6 563 54.2 13.1 464 0.0 1.5 514 55.1 11.6 564 54.2 0.4 465 0.9 41.1 515 56.8 5.7 565 53.4 0.0 466 7.0 46.3 516 42.4 0.0 566 51.4 m 467 12.8 48.5 517 27.9 8.2 567 48.7 m 468 17.0 50.7 518 29.0 15.9 568 45.6 m 469 20.9 52.9 519 30.4 25.1 569 42.4 m 470 26.7 55.0 520 32.6 60.5 570 40.4 m 471 35.5 57.2 521 35.4 72.7 571 39.8 5.8 472 46.9 23.8 522 38.4 88.2 572 40.7 39.7 473 44.5 0.0 523 41.0 65.1 573 43.8 37.1 474 42.1 45.7 524 42.9 25.6 574 48.1 39.1 475 55.6 77.4 525 44.2 15.8 575 52.0 22.0 476 68.8 100.0 526 44.9 2.9 576 54.7 13.2 477 81.7 47.9 527 45.1 m 577 56.4 13.2 478 71.2 0.0 528 44.8 m 578 57.5 6.6 479 60.7 38.3 529 43.9 m 579 42.6 0.0 480 68.8 72.7 530 42.4 m 580 27.7 10.9 481 75.0 m 531 40.2 m 581 28.5 21.3 482 61.3 m 532 37.1 m 582 29.2 23.9 483 53.5 m 533 47.0 0.0 583 29.5 15.2 484 45.9 58.0 534 57.0 m 584 29.7 8.8 485 48.1 80.0 535 45.1 m 585 30.4 20.8 486 49.4 97.9 536 32.6 m 586 31.9 22.9 487 49.7 m 537 46.8 0.0 587 34.3 61.4 488 48.7 m 538 61.5 m 588 37.2 76.6
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 589 40.1 27.5 639 39.8 m 689 46.6 0.0 590 42.3 25.4 640 36.0 m 690 32.3 34.6 591 43.5 32.0 641 29.7 m 691 32.7 68.6 592 43.8 6.0 642 21.5 m 692 32.6 67.0 593 43.5 m 643 14.1 m 693 31.3 m 594 42.8 m 644 0.0 0.0 694 28.1 m 595 41.7 m 645 0.0 0.0 695 43.0 0.0 596 40.4 m 646 0.0 0.0 696 58.0 m 597 39.3 m 647 0.0 0.0 697 58.9 m 598 38.9 12.9 648 0.0 0.0 698 49.4 m 599 39.0 18.4 649 0.0 0.0 699 41.5 m 600 39.7 39.2 650 0.0 0.0 700 48.4 0.0 601 41.4 60.0 651 0.0 0.0 701 55.3 m 602 43.7 54.5 652 0.0 0.0 702 41.8 m 603 46.2 64.2 653 0.0 0.0 703 31.6 m 604 48.8 73.3 654 0.0 0.0 704 24.6 m 605 51.0 82.3 655 0.0 0.0 705 15.2 m 606 52.1 0.0 656 0.0 3.4 706 7.0 m 607 52.0 m 657 1.4 22.0 707 0.0 0.0 608 50.9 m 658 10.1 45.3 708 0.0 0.0 609 49.4 m 659 21.5 10.0 709 0.0 0.0 610 47.8 m 660 32.2 0.0 710 0.0 0.0 611 46.6 m 661 42.3 46.0 711 0.0 0.0 612 47.3 35.3 662 57.1 74.1 712 0.0 0.0 613 49.2 74.1 663 72.1 34.2 713 0.0 0.0 614 51.1 95.2 664 66.9 0.0 714 0.0 0.0 615 51.7 m 665 60.4 41.8 715 0.0 0.0 616 50.8 m 666 69.1 79.0 716 0.0 0.0 617 47.3 m 667 77.1 38.3 717 0.0 0.0 618 41.8 m 668 63.1 0.0 718 0.0 0.0 619 36.4 m 669 49.1 47.9 719 0.0 0.0 620 30.9 m 670 53.4 91.3 720 0.0 0.0 621 25.5 37.1 671 57.5 85.7 721 0.0 0.0 622 33.8 38.4 672 61.5 89.2 722 0.0 0.0 623 42.1 m 673 65.5 85.9 723 0.0 0.0 624 34.1 m 674 69.5 89.5 724 0.0 0.0 625 33.0 37.1 675 73.1 75.5 725 0.0 0.0 626 36.4 38.4 676 76.2 73.6 726 0.0 0.0 627 43.3 17.1 677 79.1 75.6 727 0.0 0.0 628 35.7 0.0 678 81.8 78.2 728 0.0 0.0 629 28.1 11.6 679 84.1 39.0 729 0.0 0.0 630 36.5 19.2 680 69.6 0.0 730 0.0 0.0 631 45.2 8.3 681 55.0 25.2 731 0.0 0.0 632 36.5 0.0 682 55.8 49.9 732 0.0 0.0 633 27.9 32.6 683 56.7 46.4 733 0.0 0.0 634 31.5 59.6 684 57.6 76.3 734 0.0 0.0 635 34.4 65.2 685 58.4 92.7 735 0.0 0.0 636 37.0 59.6 686 59.3 99.9 736 0.0 0.0 637 39.0 49.0 687 60.1 95.0 737 0.0 0.0 638 40.2 m 688 61.0 46.7 738 0.0 0.0
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 739 0.0 0.0 789 17.2 m 839 38.1 m 740 0.0 0.0 790 14.0 37.6 840 37.2 42.7 741 0.0 0.0 791 18.4 25.0 841 37.5 70.8 742 0.0 0.0 792 27.6 17.7 842 39.1 48.6 743 0.0 0.0 793 39.8 6.8 843 41.3 0.1 744 0.0 0.0 794 34.3 0.0 844 42.3 m 745 0.0 0.0 795 28.7 26.5 845 42.0 m 746 0.0 0.0 796 41.5 40.9 846 40.8 m 747 0.0 0.0 797 53.7 17.5 847 38.6 m 748 0.0 0.0 798 42.4 0.0 848 35.5 m 749 0.0 0.0 799 31.2 27.3 849 32.1 m 750 0.0 0.0 800 32.3 53.2 850 29.6 m 751 0.0 0.0 801 34.5 60.6 851 28.8 39.9 752 0.0 0.0 802 37.6 68.0 852 29.2 52.9 753 0.0 0.0 803 41.2 75.4 853 30.9 76.1 754 0.0 0.0 804 45.8 82.8 854 34.3 76.5 755 0.0 0.0 805 52.3 38.2 855 38.3 75.5 756 0.0 0.0 806 42.5 0.0 856 42.5 74.8 757 0.0 0.0 807 32.6 30.5 857 46.6 74.2 758 0.0 0.0 808 35.0 57.9 858 50.7 76.2 759 0.0 0.0 809 36.0 77.3 859 54.8 75.1 760 0.0 0.0 810 37.1 96.8 860 58.7 36.3 761 0.0 0.0 811 39.6 80.8 861 45.2 0.0 762 0.0 0.0 812 43.4 78.3 862 31.8 37.2 763 0.0 0.0 813 47.2 73.4 863 33.8 71.2 764 0.0 0.0 814 49.6 66.9 864 35.5 46.4 765 0.0 0.0 815 50.2 62.0 865 36.6 33.6 766 0.0 0.0 816 50.2 57.7 866 37.2 20.0 767 0.0 0.0 817 50.6 62.1 867 37.2 m 768 0.0 0.0 818 52.3 62.9 868 37.0 m 769 0.0 0.0 819 54.8 37.5 869 36.6 m 770 0.0 0.0 820 57.0 18.3 870 36.0 m 771 0.0 22.0 821 42.3 0.0 871 35.4 m 772 4.5 25.8 822 27.6 29.1 872 34.7 m 773 15.5 42.8 823 28.4 57.0 873 34.1 m 774 30.5 46.8 824 29.1 51.8 874 33.6 m 775 45.5 29.3 825 29.6 35.3 875 33.3 m 776 49.2 13.6 826 29.7 33.3 876 33.1 m 777 39.5 0.0 827 29.8 17.7 877 32.7 m 778 29.7 15.1 828 29.5 m 878 31.4 m 779 34.8 26.9 829 28.9 m 879 45.0 0.0 780 40.0 13.6 830 43.0 0.0 880 58.5 m 781 42.2 m 831 57.1 m 881 53.7 m 782 42.1 m 832 57.7 m 882 47.5 m 783 40.8 m 833 56.0 m 883 40.6 m 784 37.7 37.6 834 53.8 m 884 34.1 m 785 47.0 35.0 835 51.2 m 885 45.3 0.0 786 48.8 33.4 836 48.1 m 886 56.4 m 787 41.7 m 837 44.5 m 887 51.0 m 788 27.7 m 838 40.9 m 888 44.5 m
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 889 36.4 m 939 32.7 56.5 989 32.6 m 890 26.6 m 940 33.4 62.8 990 30.9 m 891 20.0 m 941 34.6 68.2 991 29.9 m 892 13.3 m 942 35.8 68.6 992 29.2 m 893 6.7 m 943 38.6 65.0 993 44.1 0.0 894 0.0 0.0 944 42.3 61.9 994 59.1 m 895 0.0 0.0 945 44.1 65.3 995 56.8 m 896 0.0 0.0 946 45.3 63.2 996 53.5 m 897 0.0 0.0 947 46.5 30.6 997 47.8 m 898 0.0 0.0 948 46.7 11.1 998 41.9 m 899 0.0 0.0 949 45.9 16.1 999 35.9 m 900 0.0 0.0 950 45.6 21.8 1000 44.3 0.0 901 0.0 5.8 951 45.9 24.2 1001 52.6 m 902 2.5 27.9 952 46.5 24.7 1002 43.4 m 903 12.4 29.0 953 46.7 24.7 1003 50.6 0.0 904 19.4 30.1 954 46.8 28.2 1004 57.8 m 905 29.3 31.2 955 47.2 31.2 1005 51.6 m 906 37.1 10.4 956 47.6 29.6 1006 44.8 m 907 40.6 4.9 957 48.2 31.2 1007 48.6 0.0 908 35.8 0.0 958 48.6 33.5 1008 52.4 m 909 30.9 7.6 959 48.8 m 1009 45.4 m 910 35.4 13.8 960 47.6 m 1010 37.2 m 911 36.5 11.1 961 46.3 m 1011 26.3 m 912 40.8 48.5 962 45.2 m 1012 17.9 m 913 49.8 3.7 963 43.5 m 1013 16.2 1.9 914 41.2 0.0 964 41.4 m 1014 17.8 7.5 915 32.7 29.7 965 40.3 m 1015 25.2 18.0 916 39.4 52.1 966 39.4 m 1016 39.7 6.5 917 48.8 22.7 967 38.0 m 1017 38.6 0.0 918 41.6 0.0 968 36.3 m 1018 37.4 5.4 919 34.5 46.6 969 35.3 5.8 1019 43.4 9.7 920 39.7 84.4 970 35.4 30.2 1020 46.9 15.7 921 44.7 83.2 971 36.6 55.6 1021 52.5 13.1 922 49.5 78.9 972 38.6 48.5 1022 56.2 6.3 923 52.3 83.8 973 39.9 41.8 1023 44.0 0.0 924 53.4 77.7 974 40.3 38.2 1024 31.8 20.9 925 52.1 69.6 975 40.8 35.0 1025 38.7 36.3 926 47.9 63.6 976 41.9 32.4 1026 47.7 47.5 927 46.4 55.2 977 43.2 26.4 1027 54.5 22.0 928 46.5 53.6 978 43.5 m 1028 41.3 0.0 929 46.4 62.3 979 42.9 m 1029 28.1 26.8 930 46.1 58.2 980 41.5 m 1030 31.6 49.2 931 46.2 61.8 981 40.9 m 1031 34.5 39.5 932 47.3 62.3 982 40.5 m 1032 36.4 24.0 933 49.3 57.1 983 39.5 m 1033 36.7 m 934 52.6 58.1 984 38.3 m 1034 35.5 m 935 56.3 56.0 985 36.9 m 1035 33.8 m 936 59.9 27.2 986 35.4 m 1036 33.7 19.8 937 45.8 0.0 987 34.5 m 1037 35.3 35.1 938 31.8 28.8 988 33.9 m 1038 38.0 33.9
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1039 40.1 34.5 1,089 46.3 24.0 1139 51.7 0.0 1040 42.2 40.4 1,090 47.8 20.6 1140 59.2 m 1041 45.2 44.0 1,091 47.2 3.8 1141 47.2 m 1042 48.3 35.9 1,092 45.6 4.4 1142 35.1 0.0 1043 50.1 29.6 1,093 44.6 4.1 1143 23.1 m 1044 52.3 38.5 1,094 44.1 m 1144 13.1 m 1045 55.3 57.7 1,095 42.9 m 1145 5.0 m 1046 57.0 50.7 1,096 40.9 m 1146 0.0 0.0 1047 57.7 25.2 1,097 39.2 m 1147 0.0 0.0 1048 42.9 0.0 1,098 37.0 m 1148 0.0 0.0 1049 28.2 15.7 1,099 35.1 2.0 1149 0.0 0.0 1050 29.2 30.5 1,100 35.6 43.3 1150 0.0 0.0 1051 31.1 52.6 1,101 38.7 47.6 1151 0.0 0.0 1052 33.4 60.7 1,102 41.3 40.4 1152 0.0 0.0 1053 35.0 61.4 1,103 42.6 45.7 1153 0.0 0.0 1054 35.3 18.2 1,104 43.9 43.3 1154 0.0 0.0 1055 35.2 14.9 1,105 46.9 41.2 1155 0.0 0.0 1056 34.9 11.7 1,106 52.4 40.1 1156 0.0 0.0 1057 34.5 12.9 1,107 56.3 39.3 1157 0.0 0.0 1058 34.1 15.5 1108 57.4 25.5 1158 0.0 0.0 1059 33.5 m 1109 57.2 25.4 1159 0.0 0.0 1060 31.8 m 1110 57.0 25.4 1160 0.0 0.0 1061 30.1 m 1111 56.8 25.3 1161 0.0 0.0 1062 29.6 10.3 1112 56.3 25.3 1162 0.0 0.0 1063 30.0 26.5 1113 55.6 25.2 1163 0.0 0.0 1064 31.0 18.8 1114 56.2 25.2 1164 0.0 0.0 1065 31.5 26.5 1115 58.0 12.4 1165 0.0 0.0 1066 31.7 m 1116 43.4 0.0 1166 0.0 0.0 1067 31.5 m 1117 28.8 26.2 1167 0.0 0.0 1068 30.6 m 1118 30.9 49.9 1168 0.0 0.0 1069 30.0 m 1119 32.3 40.5 1169 0.0 0.0 1070 30.0 m 1120 32.5 12.4 1170 0.0 0.0 1071 29.4 m 1121 32.4 12.2 1171 0.0 0.0 1072 44.3 0.0 1122 32.1 6.4 1172 0.0 0.0 1073 59.2 m 1123 31.0 12.4 1173 0.0 0.0 1074 58.3 m 1124 30.1 18.5 1174 0.0 0.0 1075 57.1 m 1125 30.4 35.6 1175 0.0 0.0 1076 55.4 m 1126 31.2 30.1 1176 0.0 0.0 1077 53.5 m 1127 31.5 30.8 1177 0.0 0.0 1078 51.5 m 1128 31.5 26.9 1178 0.0 0.0 1079 49.7 m 1129 31.7 33.9 1179 0.0 0.0 1080 47.9 m 1130 32.0 29.9 1180 0.0 0.0 1081 46.4 m 1131 32.1 m 1181 0.0 0.0 1082 45.5 m 1132 31.4 m 1182 0.0 0.0 1083 45.2 m 1133 30.3 m 1183 0.0 0.0 1084 44.3 m 1134 29.8 m 1184 0.0 0.0 1085 43.6 m 1135 44.3 0.0 1185 0.0 0.0 1086 43.1 m 1136 58.9 m 1186 0.0 0.0 1087 42.5 25.6 1137 52.1 m 1187 0.0 0.0 1088 43.3 25.7 1138 44.1 m 1188 0.0 0.0
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1189 0.0 0.0 1239 58.5 85.4 1289 61.9 76.1 1190 0.0 0.0 1240 59.5 85.6 1290 65.6 73.7 1191 0.0 0.0 1241 61.0 86.6 1291 69.9 79.3 1192 0.0 0.0 1242 62.6 86.8 1292 74.1 81.3 1193 0.0 0.0 1243 64.1 87.6 1293 78.3 83.2 1194 0.0 0.0 1244 65.4 87.5 1294 82.6 86.0 1195 0.0 0.0 1245 66.7 87.8 1295 87.0 89.5 1196 0.0 20.4 1246 68.1 43.5 1296 91.2 90.8 1197 12.6 41.2 1247 55.2 0.0 1297 95.3 45.9 1198 27.3 20.4 1248 42.3 37.2 1298 81.0 0.0 1199 40.4 7.6 1249 43.0 73.6 1299 66.6 38.2 1200 46.1 m 1250 43.5 65.1 1300 67.9 75.5 1201 44.6 m 1251 43.8 53.1 1301 68.4 80.5 1202 42.7 14.7 1252 43.9 54.6 1302 69.0 85.5 1203 42.9 7.3 1253 43.9 41.2 1303 70.0 85.2 1204 36.1 0.0 1254 43.8 34.8 1304 71.6 85.9 1205 29.3 15.0 1255 43.6 30.3 1305 73.3 86.2 1206 43.8 22.6 1256 43.3 21.9 1306 74.8 86.5 1207 54.9 9.9 1257 42.8 19.9 1307 76.3 42.9 1208 44.9 0.0 1258 42.3 m 1308 63.3 0.0 1209 34.9 47.4 1259 41.4 m 1309 50.4 21.2 1210 42.7 82.7 1260 40.2 m 1310 50.6 42.3 1211 52.0 81.2 1261 38.7 m 1311 50.6 53.7 1212 61.8 82.7 1262 37.1 m 1312 50.4 90.1 1213 71.3 39.1 1263 35.6 m 1313 50.5 97.1 1214 58.1 0.0 1264 34.2 m 1314 51.0 100.0 1215 44.9 42.5 1265 32.9 m 1315 51.9 100.0 1216 46.3 83.3 1266 31.8 m 1316 52.6 100.0 1217 46.8 74.1 1267 30.7 m 1317 52.8 32.4 1218 48.1 75.7 1268 29.6 m 1318 47.7 0.0 1219 50.5 75.8 1269 40.4 0.0 1319 42.6 27.4 1220 53.6 76.7 1270 51.2 m 1320 42.1 53.5 1221 56.9 77.1 1271 49.6 m 1321 41.8 44.5 1222 60.2 78.7 1272 48.0 m 1322 41.4 41.1 1223 63.7 78.0 1273 46.4 m 1323 41.0 21.0 1224 67.2 79.6 1274 45.0 m 1324 40.3 0.0 1225 70.7 80.9 1275 43.6 m 1325 39.3 1.0 1226 74.1 81.1 1276 42.3 m 1326 38.3 15.2 1227 77.5 83.6 1277 41.0 m 1327 37.6 57.8 1228 80.8 85.6 1278 39.6 m 1328 37.3 73.2 1229 84.1 81.6 1279 38.3 m 1329 37.3 59.8 1230 87.4 88.3 1280 37.1 m 1330 37.4 52.2 1231 90.5 91.9 1281 35.9 m 1331 37.4 16.9 1232 93.5 94.1 1282 34.6 m 1332 37.1 34.3 1233 96.8 96.6 1283 33.0 m 1333 36.7 51.9 1234 100.0 m 1284 31.1 m 1334 36.2 25.3 1235 96.0 m 1285 29.2 m 1335 35.6 m 1236 81.9 m 1286 43.3 0.0 1336 34.6 m 1237 68.1 m 1287 57.4 32.8 1337 33.2 m 1238 58.1 84.7 1288 59.9 65.4 1338 31.6 m
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1339 30.1 m 1389 50.4 50.2 1439 36.3 98.8 1340 28.8 m 1390 53.0 26.1 1440 37.7 100.0 1341 28.0 29.5 1391 59.5 0.0 1441 39.2 100.0 1342 28.6 100.0 1392 66.2 38.4 1442 40.9 100.0 1343 28.8 97.3 1393 66.4 76.7 1443 42.4 99.5 1344 28.8 73.4 1394 67.6 100.0 1444 43.8 98.7 1345 29.6 56.9 1395 68.4 76.6 1445 45.4 97.3 1346 30.3 91.7 1396 68.2 47.2 1446 47.0 96.6 1347 31.0 90.5 1397 69.0 81.4 1447 47.8 96.2 1348 31.8 81.7 1398 69.7 40.6 1448 48.8 96.3 1349 32.6 79.5 1399 54.7 0.0 1449 50.5 95.1 1350 33.5 86.9 1400 39.8 19.9 1450 51.0 95.9 1351 34.6 100.0 1401 36.3 40.0 1451 52.0 94.3 1352 35.6 78.7 1402 36.7 59.4 1452 52.6 94.6 1353 36.4 50.5 1403 36.6 77.5 1453 53.0 65.5 1354 37.0 57.0 1404 36.8 94.3 1454 53.2 0.0 1355 37.3 69.1 1405 36.8 100.0 1455 53.2 m 1356 37.6 49.5 1406 36.4 100.0 1456 52.6 m 1357 37.8 44.4 1407 36.3 79.7 1457 52.1 m 1358 37.8 43.4 1408 36.7 49.5 1458 51.8 m 1359 37.8 34.8 1409 36.6 39.3 1459 51.3 m 1360 37.6 24.0 1410 37.3 62.8 1460 50.7 m 1361 37.2 m 1411 38.1 73.4 1461 50.7 m 1362 36.3 m 1412 39.0 72.9 1462 49.8 m 1363 35.1 m 1413 40.2 72.0 1463 49.4 m 1364 33.7 m 1414 41.5 71.2 1464 49.3 m 1365 32.4 m 1415 42.9 77.3 1465 49.1 m 1366 31.1 m 1416 44.4 76.6 1466 49.1 m 1367 29.9 m 1417 45.4 43.1 1467 49.1 8.3 1368 28.7 m 1418 45.3 53.9 1468 48.9 16.8 1369 29.0 58.6 1419 45.1 64.8 1469 48.8 21.3 1370 29.7 88.5 1420 46.5 74.2 1470 49.1 22.1 1371 31.0 86.3 1421 47.7 75.2 1471 49.4 26.3 1372 31.8 43.4 1422 48.1 75.5 1472 49.8 39.2 1373 31.7 m 1423 48.6 75.8 1473 50.4 83.4 1374 29.9 m 1424 48.9 76.3 1474 51.4 90.6 1375 40.2 0.0 1425 49.9 75.5 1475 52.3 93.8 1376 50.4 m 1426 50.4 75.2 1476 53.3 94.0 1377 47.9 m 1427 51.1 74.6 1477 54.2 94.1 1378 45.0 m 1428 51.9 75.0 1478 54.9 94.3 1379 43.0 m 1429 52.7 37.2 1479 55.7 94.6 1380 40.6 m 1430 41.6 0.0 1480 56.1 94.9 1381 55.5 0.0 1431 30.4 36.6 1481 56.3 86.2 1382 70.4 41.7 1432 30.5 73.2 1482 56.2 64.1 1383 73.4 83.2 1433 30.3 81.6 1483 56.0 46.1 1384 74.0 83.7 1434 30.4 89.3 1484 56.2 33.4 1385 74.9 41.7 1435 31.5 90.4 1485 56.5 23.6 1386 60.0 0.0 1436 32.7 88.5 1486 56.3 18.6 1387 45.1 41.6 1437 33.7 97.2 1487 55.7 16.2 1388 47.7 84.2 1438 35.2 99.7 1488 56.0 15.9
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1489 55.9 21.8 1539 57.0 59.5 1589 56.8 42.9 1490 55.8 20.9 1540 56.7 57.0 1590 56.5 42.8 1491 55.4 18.4 1541 56.7 69.8 1591 56.7 43.2 1492 55.7 25.1 1542 56.8 58.5 1592 56.5 42.8 1493 56.0 27.7 1543 56.8 47.2 1593 56.9 42.2 1494 55.8 22.4 1544 57.0 38.5 1594 56.5 43.1 1495 56.1 20.0 1545 57.0 32.8 1595 56.5 42.9 1496 55.7 17.4 1546 56.8 30.2 1596 56.7 42.7 1497 55.9 20.9 1547 57.0 27.0 1597 56.6 41.5 1498 56.0 22.9 1548 56.9 26.2 1598 56.9 41.8 1499 56.0 21.1 1549 56.7 26.2 1599 56.6 41.9 1500 55.1 19.2 1550 57.0 26.6 1600 56.7 42.6 1501 55.6 24.2 1551 56.7 27.8 1601 56.7 42.6 1502 55.4 25.6 1552 56.7 29.7 1602 56.7 41.5 1503 55.7 24.7 1553 56.8 32.1 1603 56.7 42.2 1504 55.9 24.0 1554 56.5 34.9 1604 56.5 42.2 1505 55.4 23.5 1555 56.6 34.9 1605 56.8 41.9 1506 55.7 30.9 1556 56.3 35.8 1606 56.5 42.0 1507 55.4 42.5 1557 56.6 36.6 1607 56.7 42.1 1508 55.3 25.8 1558 56.2 37.6 1608 56.4 41.9 1509 55.4 1.3 1559 56.6 38.2 1609 56.7 42.9 1510 55.0 m 1560 56.2 37.9 1610 56.7 41.8 1511 54.4 m 1561 56.6 37.5 1611 56.7 41.9 1512 54.2 m 1562 56.4 36.7 1612 56.8 42.0 1513 53.5 m 1563 56.5 34.8 1613 56.7 41.5 1514 52.4 m 1564 56.5 35.8 1614 56.6 41.9 1515 51.8 m 1565 56.5 36.2 1615 56.8 41.6 1516 50.7 m 1566 56.5 36.7 1616 56.6 41.6 1517 49.9 m 1567 56.7 37.8 1617 56.9 42.0 1518 49.1 m 1568 56.7 37.8 1618 56.7 40.7 1519 47.7 m 1569 56.6 36.6 1619 56.7 39.3 1520 47.3 m 1570 56.8 36.1 1620 56.5 41.4 1521 46.9 m 1571 56.5 36.8 1621 56.4 44.9 1522 46.9 m 1572 56.9 35.9 1622 56.8 45.2 1523 47.2 m 1573 56.7 35.0 1623 56.6 43.6 1524 47.8 m 1574 56.5 36.0 1624 56.8 42.2 1525 48.2 0.0 1575 56.4 36.5 1625 56.5 42.3 1526 48.8 23.0 1576 56.5 38.0 1626 56.5 44.4 1527 49.1 67.9 1577 56.5 39.9 1627 56.9 45.1 1528 49.4 73.7 1578 56.4 42.1 1628 56.4 45.0 1529 49.8 75.0 1579 56.5 47.0 1629 56.7 46.3 1530 50.4 75.8 1580 56.4 48.0 1630 56.7 45.5 1531 51.4 73.9 1581 56.1 49.1 1631 56.8 45.0 1532 52.3 72.2 1582 56.4 48.9 1632 56.7 44.9 1533 53.3 71.2 1583 56.4 48.2 1633 56.6 45.2 1534 54.6 71.2 1584 56.5 48.3 1634 56.8 46.0 1535 55.4 68.7 1585 56.5 47.9 1635 56.5 46.6 1536 56.7 67.0 1586 56.6 46.8 1636 56.6 48.3 1537 57.2 64.6 1587 56.6 46.2 1637 56.4 48.6 1538 57.3 61.9 1588 56.5 44.4 1638 56.6 50.3
Annex 4 – Appendix 1 Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1639 56.3 51.9 1689 57.6 8.9 1739 56.1 46.8 1640 56.5 54.1 1690 57.5 8.0 1740 56.1 45.8 1641 56.3 54.9 1691 57.5 5.8 1741 56.2 46.0 1642 56.4 55.0 1692 57.3 5.8 1742 56.3 45.9 1643 56.4 56.2 1693 57.6 5.5 1743 56.3 45.9 1644 56.2 58.6 1694 57.3 4.5 1744 56.2 44.6 1645 56.2 59.1 1695 57.2 3.2 1745 56.2 46.0 1646 56.2 62.5 1696 57.2 3.1 1746 56.4 46.2 1647 56.4 62.8 1697 57.3 4.9 1747 55.8 m 1648 56.0 64.7 1698 57.3 4.2 1748 55.5 m 1649 56.4 65.6 1699 56.9 5.5 1749 55.0 m 1650 56.2 67.7 1700 57.1 5.1 1750 54.1 m 1651 55.9 68.9 1701 57.0 5.2 1751 54.0 m 1652 56.1 68.9 1702 56.9 5.5 1752 53.3 m 1653 55.8 69.5 1703 56.6 5.4 1753 52.6 m 1654 56.0 69.8 1704 57.1 6.1 1754 51.8 m 1655 56.2 69.3 1705 56.7 5.7 1755 50.7 m 1656 56.2 69.8 1706 56.8 5.8 1756 49.9 m 1657 56.4 69.2 1707 57.0 6.1 1757 49.1 m 1658 56.3 68.7 1708 56.7 5.9 1758 47.7 m 1659 56.2 69.4 1709 57.0 6.6 1759 46.8 m 1660 56.2 69.5 1710 56.9 6.4 1760 45.7 m 1661 56.2 70.0 1711 56.7 6.7 1761 44.8 m 1662 56.4 69.7 1712 56.9 6.9 1762 43.9 m 1663 56.2 70.2 1713 56.8 5.6 1763 42.9 m 1664 56.4 70.5 1714 56.6 5.1 1764 41.5 m 1665 56.1 70.5 1715 56.6 6.5 1765 39.5 m 1666 56.5 69.7 1716 56.5 10.0 1766 36.7 m 1667 56.2 69.3 1717 56.6 12.4 1767 33.8 m 1668 56.5 70.9 1718 56.5 14.5 1768 31.0 m 1669 56.4 70.8 1719 56.6 16.3 1769 40.0 0.0 1670 56.3 71.1 1720 56.3 18.1 1770 49.1 m 1671 56.4 71.0 1721 56.6 20.7 1771 46.2 m 1672 56.7 68.6 1722 56.1 22.6 1772 43.1 m 1673 56.8 68.6 1723 56.3 25.8 1773 39.9 m 1674 56.6 68.0 1724 56.4 27.7 1774 36.6 m 1675 56.8 65.1 1725 56.0 29.7 1775 33.6 m 1676 56.9 60.9 1726 56.1 32.6 1776 30.5 m 1677 57.1 57.4 1727 55.9 34.9 1777 42.8 0.0 1678 57.1 54.3 1728 55.9 36.4 1778 55.2 m 1679 57.0 48.6 1729 56.0 39.2 1779 49.9 m 1680 57.4 44.1 1730 55.9 41.4 1780 44.0 m 1681 57.4 40.2 1731 55.5 44.2 1781 37.6 m 1682 57.6 36.9 1732 55.9 46.4 1782 47.2 0.0 1683 57.5 34.2 1733 55.8 48.3 1783 56.8 m 1684 57.4 31.1 1734 55.6 49.1 1784 47.5 m 1685 57.5 25.9 1735 55.8 49.3 1785 42.9 m 1686 57.5 20.7 1736 55.9 47.7 1786 31.6 m 1687 57.6 16.4 1737 55.9 47.4 1787 25.8 m 1688 57.6 12.4 1738 55.8 46.9 1788 19.9 m
Time Norm. speed Norm. torque Time Norm. speed Norm. torque Time Norm. speed Norm. torque per cent per cent s per cent per cent s per cent per cent 1789 14.0 m 1790 8.1 m 1791 2.2 m 1792 0.0 0.0 1793 0.0 0.0 1794 0.0 0.0 1795 0.0 0.0 1796 0.0 0.0 1797 0.0 0.0 1798 0.0 0.0 1799 0.0 0.0 1800 0.0 0.0
m = motoring
Annex 4 – Appendix 2
Annex 4 - Appendix 2 — Measurement equipment
A.2.1. This appendix contains the basic requirements and the general descriptions of the sampling and analyzing systems for gaseous and particulate emissions measurement. Since various configurations can produce equivalent results, exact conformance with the figures of this appendix is not required. Components such as instruments, valves, solenoids, pumps, flow devices and switches may be used to provide additional information and coordinate the functions of the component systems. Other components which are not needed to maintain the accuracy on some systems may be excluded if their exclusion is based upon good engineering judgement. A.2.1.1. Analytical system A.2.1.2. Description of the analytical system Analytical system for the determination of the gaseous emissions in the raw exhaust gas (Figure 9) or in the diluted exhaust gas (Figure 10) are described based on the use of:
(a) HFID or FID analyzer for the measurement of hydrocarbons;
(b) NDIR analyzers for the measurement of carbon monoxide and carbon dioxide;
(c) HCLD or CLD analyzer for the measurement of the oxides of nitrogen. The sample for all components should be taken with one sampling probe and internally split to the different analyzers. Optionally, two sampling probes located in close proximity may be used. Care shall be taken that no unintended condensation of exhaust components (including water and sulphuric acid) occurs at any point of the analytical system.
Annex 4 - Appendix 3 — Statistics
A.3.1. Mean value and standard deviation The arithmetic mean value shall be calculated as follows: n
x i x i 1
n (102) The standard deviation shall be calculated as follows:
x x n i s i 1
n 1 (103) A.3.2. Regression analysis The slope of the regression shall be calculated as follows:
y y x x n
i i a1 i 1 x x n i i 1 (104) The y intercept of the regression shall be calculated as follows:
a0 y a1 x (105) The standard error of estimate (SEE) shall be calculated as follows:
n 2
y a a x i 1 i 0 1 i
SEE n2 (106) The coefficient of determination shall be calculated as follows: n 2
y a a x i 0 1 i r 1 i 1
y y n i i 1 (107) A.3.3. Determination of system equivalency The determination of system equivalency according to paragraph 5.1.1. of this annex shall be based on a seven sample pair (or larger) correlation study between the candidate system and one of the accepted reference systems of this annex using the appropriate test cycle(s). The equivalency criteria to be applied shall be the F-test and the two-sided Student t-test.
Annex 4 – Appendix 3
This statistical method examines the hypothesis that the sample standard deviation and sample mean value for an emission measured with the candidate system do not differ from the sample standard deviation and sample mean value for that emission measured with the reference system. The hypothesis shall be tested on the basis of a 10 per cent significance level of the F and t values. The critical F and t values for seven to ten sample pairs are given in Table 9. If the F and t values calculated according to the equation below are greater than the critical F and t values, the candidate system is not equivalent. The following procedure shall be followed. The subscripts R and C refer to the reference and candidate system, respectively:
(a) Conduct at least seven tests with the candidate and reference systems operated in parallel. The number of tests is referred to as nR and nC;
(b) Calculate the mean values x R and x C and the standard deviations sR and sC;
(c) Calculate the F value, as follows: s major F 2 s minor (108) (the greater of the two standard deviations sR or sC shall be in the numerator);
(d) Calculate the t value, as follows:
xC x R t sC2 nC sR2 nR (109)
(e) Compare the calculated F and t values with the critical F and t values corresponding to the respective number of tests indicated in Table 9. If larger sample sizes are selected, consult statistical tables for 10 per cent significance (90 per cent confidence) level;
(f) Determine the degrees of freedom (df), as follows: For the F-test: df1 = nR –1, df2 = nC –1 (110) For the t-test: df = (nC + nR –2)/2 (111)
(g) Determine the equivalency, as follows:
(i) If F < Fcrit and t < tcrit, then the candidate system is equivalent to the reference system of this annex;
(ii) If F Fcrit or t tcrit , then the candidate system is different from the reference system of this annex.
t and F values for selected sample sizes
Sample Size F-test t-test
df Fcrit df tcrit
7 6, 6 3.055 6 1.943
8 7, 7 2.785 7 1.895
9 8, 8 2.589 8 1.860
10 9, 9 2.440 9 1.833
Annex 4 – Appendix 4Annex 4 - Appendix 4 — Carbon flow check
A.4.1. Introduction All but a tiny part of the carbon in the exhaust comes from the fuel, and all but a minimal part of this is manifest in the exhaust gas as CO 2. This is the basis for a system verification check based on CO2 measurements. The flow of carbon into the exhaust measurement systems is determined from the fuel flow rate. The flow of carbon at various sampling points in the emissions and particulate sampling systems is determined from the CO 2 concentrations and gas flow rates at those points. In this sense, the engine provides a known source of carbon flow, and observing the same carbon flow in the exhaust pipe and at the outlet of the partial flow PM sampling system verifies leak integrity and flow measurement accuracy. This check has the advantage that the components are operating under actual engine test conditions of temperature and flow.
Annex 4 - Appendix 5 — Example of calculation procedure
A.5.1. Speed and torque denormalization procedure As an example, the following test point shall be denormalized: per cent speed = 43 per cent per cent torque = 82 per cent Given the following values: nlo = 1,015 min-1 nhi = 2,200 min-1 npref = 1,300 min-1 nidle = 600 min-1 results in:
actual speed = 43 0,45 1 015 0,45 1 300 0,1 2 200 600 2 ,0327 600 = = 1,178 min-1
With the maximum torque of 700 Nm observed from the mapping curve at 1,178 min-1
actual torque = 82 700 = 574 Nm A.5.2. Basic data for stoichiometric calculations Atomic mass of hydrogen 1.00794 g/atom Atomic mass of carbon 12.011 g/atom Atomic mass of sulphur 32.065 g/atom Atomic mass of nitrogen 14.0067 g/atom Atomic mass of oxygen 15.9994 g/atom Atomic mass of argon 39.9 g/atom Molar mass of water 18.01534 g/mol Molar mass of carbon dioxide 44.01 g/mol Molar mass of carbon monoxide 28.011 g/mol Molar mass of oxygen 31.9988 g/mol Molar mass of nitrogen 28.011 g/mol Molar mass of nitric oxide 30.008 g/mol Molar mass of nitrogen dioxide 46.01 g/mol Molar mass of sulphur dioxide 64.066 g/mol Molar mass of dry air 28.965 g/mol
Assuming no compressibility effects, all gases involved in the engine intake/combustion/exhaust process can be considered to be ideal and any volumetric calculations shall therefore be based on a molar volume of 22.414 l/mol according to Avogadro's hypothesis. A.5.3. Gaseous emissions (diesel fuel) The measurement data of an individual point of the test cycle (data sampling rate of 1 Hz) for the calculation of the instantaneous mass emission are shown below. In this example, CO and NOx are measured on a dry basis, HC on a wet basis. The HC concentration is given in propane equivalent (C3) and has to be multiplied by 3 to result in the C1 equivalent. The calculation procedure is identical for the other points of the cycle. The calculation example shows the rounded intermediate results of the different steps for better illustration. It should be noted that for actual calculation, rounding of intermediate results is not permitted (see paragraph 8. of this annex).
Ta,i Ha,i Wact qmew,i qmaw,i qmf,i cHC,i cCO,i cNOx,i (K) (g/kg) (kWh) (kg/s) (kg/s) (kg/s) (ppm) (ppm) (ppm)
295 8.0 40 0.155 0.150 0.005 10 40 500
The following fuel composition is considered:
Component Molar ratio Per cent mass
H = 1.8529 wALF = 13.45
C = 1.0000 wBET = 86.50
S = 0.0002 wGAM = 0.050
N = 0.0000 wDEL = 0.000
O = 0.0000 wEPS = 0.000
Step 1: Dry/wet correction (paragraph 8.1. of this annex): Equation 16: kf = 0.055584 x 13.45 - 0.0001083 x 86.5 - 0.0001562 x 0.05 = 0.7382 Equation 13: 0.005 1.2434 8 111.12 13.45 kw,a= 1 0.148 1.008 = 0.9331 773.4 1.2434 8 0.005 0.7382 1,000 0.148 Equation 12: cCO,i (wet) = 40 x 0.9331 = 37.3 ppm cNOx,i (wet) = 500 x 0.9331 = 466.6 ppm Step 2: NOx correction for temperature and humidity (paragraph 8.2.1. of this annex):
Annex 4 – Appendix 5
Equation 23: 15.698 8,00 k h,D 0.832 = 0.9576 1 000 Step 3: Calculation of the instantaneous emission of each individual point of the cycle (paragraph 8.4.2.3. of this annex): Equation 36: mHC,i = 10 x 3 x 0.155 = 4.650 mCO,i = 37.3 x 0.155 = 5.782 mNox,I = 466.6 x 0.9576 x 0.155 = 69.26 Step 4: Calculation of the mass emission over the cycle by integration of the instantaneous emission values and the u values from Table 5 (paragraph 8.4.2.3. of this annex): The following calculation is assumed for the WHTC cycle (1,800 s) and the same emission in each point of the cycle. Equation 36: mHC = 0.000479 x 4.650 = 4.01 g/test i 1
mCO = 0.000966 x 5.782 = 10.05 g/test i 1
mNOx = 0.001586 x 69.26 = 197.72 g/test i 1
Step 5: Calculation of the specific emissions (paragraph 8.6.3. of this annex): Equation 69: eHC = 4.01 / 40 = 0.10 g/kWh eCO= 10.05 / 40 = 0.25 g/kWh eNOx = 197.72 / 40 = 4.94 g/kWh A.5.4. Particulate Emission (diesel fuel) pb,b pb,a Wact qmew,i qmf,i qmdw,i qmdew,i muncor,b muncor,a msep (kPa) (kPa) (kWh) (kg/s) (kg/s) (kg/s) (kg/s) (mg) (mg) (kg)
99 100 40 0.155 0.005 0.0015 0.0020 90.0000 91.7000 1.515
Step 1: Calculation of medf (paragraph 8.4.3.2.2. of this annex): Equation 48: rd,I = 0.002 =4 0.002 0.0015
Equation 47: qmedf,I = 0.155 x 4 = 0.620 kg/s
Equation 46: medf = 0.620 = 1,116 kg/test i 1
Step 2: Buoyancy correction of the particulate mass (paragraph 8.3. of this annex): Before test: Equation 26:
ρa,b = 99 28.836 = 1.164 kg/m3 8.3144 295 Equation 25:
mf,T = 90.0000 1 1.164 / 8,000 = 90.0325 mg 1 1.164 / 2,300 After test: Equation 26:
ρa,a = 100 28.836 = 1.176 kg/m3 8.3144 295 Equation 25:
mf,G = 91.7000 1 1.176 / 8,000 = 91.7334 mg 1 1.176 / 2,300 Equation 27: mp = 91.7334 mg – 90.0325 mg = 1.7009 mg Step 3: Calculation of the particulate mass emission (paragraph 8.4.3.2.2. of this annex): Equation 45:
mPM = 1.7009 1,116 = 1.253 g/test 1.515 1,000 Step 4: Calculation of the specific emission (paragraph 8.6.3. of this annex): Equation 69: ePM = 1.253 / 40 = 0.031 g/kWh A.5.5. λ-Shift factor (Sλ) A.5.5.1. Calculation of the λ-shift factor (Sλ)1 Sλ inert% m O* 1 n 2 100 4 100
Stoichiometric Air/Fuel ratios of automotive fuels - SAE J1829, June 1987. John B. Heywood, Internal combustion engine fundamentals, McGraw-Hill, 1988, Chapter 3.4 "Combustion stoichiometry" (pp. 68 to 72).
Annex 4 – Appendix 5
Where: Sλ = λ-shift factor; inert % = per cent by volume of inert gases in the fuel (i.e. N2, CO2, He, etc.);
O *2 = per cent by volume of original oxygen in the fuel; n and m = refer to average CnHm representing the fuel hydrocarbons, i.e: CH 4 % C2 % C3 % C4 % C5 % 1 2 100 3 100 4 100 5 100 .. n 100 1 diluent % CH 4 % C H % C H % C H % 4 4 2 4 6 2 6 ...8 3 8 .. m 100 100 100 100 1 diluent % Where: CH4 = per cent by volume of methane in the fuel; C2 = per cent by volume of all C2 hydrocarbons (e.g.: C2H6, C2H4, etc.) in the fuel; C3 = per cent by volume of all C3 hydrocarbons (e.g.: C3H8, C3H6, etc.) in the fuel; C4 = per cent by volume of all C4 hydrocarbons (e.g.: C4H10, C4H8, etc.) in the fuel; C5 = per cent by volume of all C5 hydrocarbons (e.g.: C5H12, C5H10, etc.) in the fuel; diluent = per cent by volume of dilution gases in the fuel (i.e.: O2*, N2, CO2, He, etc.). A.5.5.2. Examples for the calculation of the λ-shift factor Sλ: Example 1: G25: CH4 = 86 per cent, N2 = 14 per cent (by volume) CH 4 % C % 1 2 2 .. 100 100 1 0.86 0.86 n 1 1 diluent % 14 0.86 1 100 100
CH 4 % C H % 4 4 2 4 .. 100 100 4 0.86 m 4 1 diluent % 0.86 2 2 Sλ 1.16 inert% m O*2 1 14 1 4 1 n 100 4 100 100 4
Example 2: GR: CH4 = 87 per cent, C2H6 = 13 per cent (by vol) CH 4 % C % 1 2 2 .. 100 100 1 0.87 2 0.13 1.13 n 1.13 1 diluent % 0 1 100 100 CH 4 % C2H 4 % 4 4 100 .. 4 0.87 6 0.13 100 m 4.26 1 diluent % 1 2 2 Sλ 0.911 inert% m O *2 1 0 1.13 4.26 1 n 100 4 100 100 4
Example 3: USA: CH4 = 89 per cent, C2H6 = 4.5 per cent, C3H8 = 2.3 per cent, C6H14 = 0.2 per cent, O2 = 0.6 per cent, N2 = 4 per cent CH 4 % C2 % 1 2 100 .. 1 0.89 2 0.045 3 0.023 4 0.002 100 n 1.11 1 diluent % 0.64 4 1 100 100
CH 4 % C H % C H % C H % 4 + 4 2 4 + 6 2 6 + .. + 8 3 8 m= 100 100 100 100 = diluent % 1 4 0.89 + 4 0.045 + 8 0.023 + 14 0.002 = = 4,24 0.6 + 4 1
2 2 Sλ 0.96 inert% m O* 4 4.24 0.6 1 n 2 1 1.11 100 4 100 100 4 100
Annex 4 – Appendix 6
Annex 4 - Appendix 6 — Installation of auxiliaries and equipment for emissions test
Number Auxiliaries Fitted for emission test
1 Inlet system Inlet manifold Yes Crankcase emission control system Yes Control devices for dual induction inlet manifold system Yes Air flow meter Yes Air inlet duct work Yes, or test cell equipment Air filter Yes, or test cell equipment Inlet silencer Yes, or test cell equipment Speed-limiting device Yes 2 Induction-heating device of inlet manifold Yes, if possible to be set in the most favourable condition 3 Exhaust system Exhaust manifold Yes Connecting pipes Yes Silencer Yes Tail pipe Yes Exhaust brake No, or fully open Pressure charging device Yes 4 Fuel supply pump Yes 5 Equipment for gas engines Electronic control system, air flow meter, etc. Yes Pressure reducer Yes Evaporator Yes Mixer Yes 6 Fuel injection equipment Prefilter Yes Filter Yes Pump Yes High-pressure pipe Yes Injector Yes Air inlet valve Yes Electronic control system, sensors, etc. Yes Governor/control system Yes Automatic full-load stop for the control rack depending Yes on atmospheric conditions
Number Auxiliaries Fitted for emission test 7 Liquid-cooling equipment Radiator No Fan No Fan cowl No Water pump Yes Thermostat Yes, may be fixed fully open 8 Air cooling Cowl No Fan or Blower No Temperature-regulating device No 9 Electrical equipment Generator No Coil or coils Yes Wiring Yes Electronic control system Yes 10 Intake air charging equipment Compressor driven either directly by the engine and/or Yes by the exhaust gases Charge air cooler Yes, or test cell system Coolant pump or fan (engine-driven) No Coolant flow control device Yes 11 Anti-pollution device (exhaust after-treatment system) Yes 12 Starting equipment Yes, or test cell system 13 Lubricating oil pump Yes
Annex 4 – Appendix 7
Annex 4 - Appendix 7 — Procedure for the measurement of ammonia
A.7.1. This appendix describes the procedure for measurement of ammonia (NH 3). For non-linear analysers, the use of linearising circuits shall be permitted. A.7.2. Two measurement principles are specified for NH3 measurement and either principle may be used provided it meets the criteria specified in paragraph A.7.2.1. or A.7.2.2., respectively. Gas dryers shall not be permitted for NH3 measurement. A.7.2.1. Laser Diode Spectrometer (LDS) A.7.2.1.1. Measurement principle The LDS employs the single line spectroscopy principle. The NH 3 absorption line is chosen in the near infrared spectral range and scanned by a single- mode diode laser. A.7.2.1.2. Installation The analyser shall be installed either directly in the exhaust pipe (in-situ) or within an analyser cabinet using extractive sampling in accordance with the instrument manufacturers instructions. If installed in an analyser cabinet, the sample path (sampling line, pre-filter(s) and valves) shall be made of stainless steel or PTFE and shall be heated to 463 ± 10 K (190 ± 10 °C) in order to minimize NH3 losses and sampling artefacts. In addition, the sampling line shall be as short as practically possible. Influence from exhaust temperature and pressure, installation environment and vibrations on the measurement shall be minimized, or compensation techniques be used. If applicable, sheath air used in conjunction with in-situ measurement for protection of the instrument, shall not affect the concentration of any exhaust component measured downstream of the device, or sampling of other exhaust components shall be made upstream of the device. A.7.2.1.3. Cross interference The spectral resolution of the laser shall be within 0.5 cm-1 in order to minimize cross interference from other gases present in the exhaust gas. A.7.2.2. Fourier Transform Infrared (hereinafter FTIR) analyser A.7.2.2.1. Measurement principle The FTIR employs the broad waveband infrared spectroscopy principle. It allows simultaneous measurement of exhaust components whose standardized spectra are available in the instrument. The absorption spectrum (intensity/wavelength) is calculated from the measured interferogram (intensity/time) by means of the Fourier transform method.
A.7.2.2.2. Installation and sampling The FTIR shall be installed in accordance with the instrument manufacturer's instructions. The NH3 wavelength shall be selected for evaluation. The sample path (sampling line, pre-filter(s) and valves) shall be made of stainless steel or PTFE and shall be heated to 463 ± 10 K (190 ± 10 °C) in order to minimize NH3 losses and sampling artefacts. In addition, the sampling line shall be as short as practically possible. A.7.2.2.3. Cross interference The spectral resolution of the NH3 wavelength shall be within 0.5 cm-1 in order to minimize cross interference from other gases present in the exhaust gas. A.7.3. Emissions test procedure and evaluation A.7.3.1. Checking the analysers Prior to the emissions test, the analyser range shall be selected. Emission analysers with automatic or manual range switching shall be permitted. During the test cycle, the range of the analysers shall not be switched. Zero and span response shall be determined, if the provisions of paragraph A.7.3.4.2. do not apply for the instrument. For the span response, a NH3 gas that meets the specifications of paragraph A.7.4.2.7. shall be used. The use of reference cells that contain NH3 span gas is permitted. A.7.3.2. Collection of emission relevant data At the start of the test sequence, the NH3 data collection shall be started, simultaneously. The NH3 concentration shall be measured continuously and stored with at least 1 Hz on a computer system. A.7.3.3. Operations after test At the completion of the test, sampling shall continue until system response times have elapsed. Determination of analyser's drift according to paragraph A.7.3.4.1. shall only be required if the information in paragraph A.7.3.4.2. is not available. A.7.3.4. Analyser drift A.7.3.4.1. As soon as practical but no later than 30 minutes after the test cycle is complete or during the soak period, the zero and span responses of the analyser shall be determined. The difference between the pre-test and post- test results shall be less than 2 per cent of full scale. A.7.3.4.2. Determination of analyser drift is not required in the following situations:
(a) If the zero and span drift specified by the instrument manufacturer in paragraphs A.7.4.2.3. and A.7.4.2.4. meets the requirements of paragraph A.7.3.4.1.,
(b) The time interval for zero and span drift specified by the instrument manufacturer in paragraphs A.7.4.2.3. and A.7.4.2.4. exceeds the duration of the test.
Annex 4 – Appendix 7
A.7.3.5. Data evaluation The average NH3 concentration (ppm/test) shall be determined by integrating the instantaneous values over the cycle. The following equation shall be applied: i n
cNH3 = c NH3,i in ppm/test) (115) n i 1
Where: cNH3,I is the instantaneous NH3 concentration in the exhaust gas, ppm n is the number of measurements For the WHTC, the final test result shall be determined with the following equation:
c NH3 0.14 c NH3,cold 0.86 c NH3,hot (116)
Where: cNH3,cold is the average NH3 concentration of the cold start test, ppm cNH3,hot is the average NH3 concentration of the hot start test, ppm A.7.4. Analyser specification and verification A.7.4.1. Linearity requirements The analyser shall comply with the linearity requirements specified in Table 7 of this annex. The linearity verification in accordance with paragraph 9.2.1. of this annex, shall be performed at least every 12 months or whenever a system repair or change is made that could influence calibration. With the prior approval of the Type Approval Authority, less than 10 reference points are permitted, if an equivalent accuracy can be demonstrated. For the linearity verification, a NH3 gas that meets the specifications of paragraph A.7.4.2.7. shall be used. The use of reference cells that contain NH3 span gas shall be permitted. Instruments, whose signals are used for compensation algorithms, shall meet the linearity requirements specified in Table 7 of this annex. Linearity verification shall be done as required by internal audit procedures, by the instrument manufacturer or in accordance with ISO 9000 requirements. A.7.4.2. Analyser specifications The analyser shall have a measuring range and response time appropriate for the accuracy required to measure the concentration of NH 3 under transient and steady state conditions. A.7.4.2.1. Minimum detection limit The analyser shall have a minimum detection limit of < 2 ppm under all conditions of testing. A.7.4.2.2. Accuracy The accuracy, defined as the deviation of the analyser reading from the reference value, shall not exceed ± 3 per cent of the reading or ± 2 ppm, whichever is larger.
A.7.4.2.3. Zero drift The drift of the zero response and the related time interval shall be specified by the instrument manufacturer. A.7.4.2.4. Span drift The drift of the span response and the related time interval shall be specified by the instrument manufacturer. A.7.4.2.5. System response time The system response time shall be 20 s. A.7.4.2.6. Rise time The rise time of the analyser shall be 5 s. A.7.4.2.7. NH3 calibration gas A gas mixture with the following chemical composition shall be available. NH3 and purified nitrogen. The true concentration of the calibration gas shall be within ±3 per cent of the nominal value. The concentration of NH3 shall be given on a volume basis (volume per cent or volume ppm). The expiration date of the calibration gases stated by the manufacturer shall be recorded. A.7.5. Alternative systems Other systems or analysers may be approved by the Type Approval Authority, if it is found that they yield equivalent results in accordance with paragraph 5.1.1. of this annex. "Results" shall refer to average cycle specific NH3 concentrations.
Annex 4 – Appendix 8
Annex 4 - Appendix 8 — Particle number emissions measurement equipment
A.8.1. Specification A.8.1.1. System overview A.8.1.1.1. The particle sampling system shall consist of a probe or sampling point extracting a sample from a homogenously mixed flow in a dilution system as described in Appendix 2 to this annex, paragraph A.2.2.1. and A.2.2.2. or A.2.2.3. and A.2.2.4., a volatile particle remover (VPR) upstream of a particle number counter (PNC) and suitable transfer tubing. A.8.1.1.2. It is recommended that a particle size pre-classifier (e.g. cyclone, impactor, etc.) be located prior to the inlet of the VPR. However, a sample probe acting as an appropriate size-classification device, such as that shown in Appendix 2 to this annex, Figure 14, is an acceptable alternative to the use of a particle size pre-classifier. In the case of partial flow dilution systems it is acceptable to use the same pre-classifier for particulate mass and particle number sampling, extracting the particle number sample from the dilution system downstream of the pre-classifier. Alternatively separate pre-classifiers may be used, extracting the particle number sample from the dilution system upstream of the particulate mass pre-classifier. A.8.1.2. General requirements A.8.1.2.1. The particle sampling point shall be located within a dilution system. The sampling probe tip or particle sampling point and particle transfer tube (PTT) together comprise the particle transfer system (PTS). The PTS conducts the sample from the dilution tunnel to the entrance of the VPR. The PTS shall meet the following conditions: In the case of full flow dilution systems and partial flow dilution systems of the fractional sampling type (as described in Appendix 2 to this annex, paragraph A.2.2.1.) the sampling probe shall be installed near the tunnel centre line, 10 to 20 tunnel diameters downstream of the gas inlet, facing upstream into the tunnel gas flow with its axis at the tip parallel to that of the dilution tunnel. The sampling probe shall be positioned within the dilution tract so that the sample is taken from a homogeneous diluent/exhaust mixture. In the case of partial flow dilution systems of the total sampling type (as described in Appendix 2 to this annex, paragraph A.2.2.1.) the particle sampling point or sampling probe shall be located in the particulate transfer tube, upstream of the particulate filter holder, flow measurement device and any sample/bypass bifurcation point. The sampling point or sampling probe shall be positioned so that the sample is taken from a homogeneous diluent/exhaust mixture. The dimensions of the particle sampling probe should be sized not to interfere with the operation of the partial flow dilution system.
Sample gas drawn through the PTS shall meet the following conditions: In the case of full flow dilution systems, it shall have a flow Reynolds number (Re) of < 1,700; In the case of partial flow dilution systems, it shall have a flow Reynolds number (Re) of < 1,700 in the PTT i.e. downstream of the sampling probe or point; It shall have a residence time in the PTS of ≤ 3 seconds. Any other sampling configuration for the PTS for which equivalent particle penetration at 30 nm can be demonstrated will be considered acceptable. The outlet tube (OT) conducting the diluted sample from the VPR to the inlet of the PNC shall have the following properties: It shall have an internal diameter of ≥ 4 mm; Sample Gas flow through the OT shall have a residence time of ≤ 0.8 second. Any other sampling configuration for the OT for which equivalent particle penetration at 30 nm can be demonstrated will be considered acceptable. A.8.1.2.2. The VPR shall include devices for sample dilution and for volatile particle removal. A.8.1.2.3. All parts of the dilution system and the sampling system from the exhaust pipe up to the PNC, which are in contact with raw and diluted exhaust gas, shall be designed to minimize deposition of the particles. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects. A.8.1.2.4. The particle sampling system shall incorporate good aerosol sampling practice that includes the avoidance of sharp bends and abrupt changes in cross-paragraph, the use of smooth internal surfaces and the minimisation of the length of the sampling line. Gradual changes in the cross-section are permissible. A.8.1.3. Specific requirements A.8.1.3.1. The particle sample shall not pass through a pump before passing through the PNC. A.8.1.3.2. A sample pre-classifier is recommended. A.8.1.3.3. The sample preconditioning unit shall: A.8.1.3.3.1. Be capable of diluting the sample in one or more stages to achieve a particle number concentration below the upper threshold of the single particle count mode of the PNC and a gas temperature below 35 °C at the inlet to the PNC; A.8.1.3.3.2. Include an initial heated dilution stage which outputs a sample at a temperature of 150 °C and ≤ 400 °C, and dilutes by a factor of at least 10; A.8.1.3.3.3. Control heated stages to constant nominal operating temperatures, within the range specified in paragraph A.8.1.3.3.2., to a tolerance of ±10 °C. Provide an indication of whether or not heated stages are at their correct operating temperatures;
Annex 4 – Appendix 8
A.8.1.3.3.4. Achieve a particle concentration reduction factor (fr(di)), as defined in paragraph A.8.2.2.2. below, for particles of 30 nm and 50 nm electrical mobility diameters, that is no more than 30 per cent and 20 per cent respectively higher, and no more than 5 per cent lower than that for particles of 100 nm electrical mobility diameter for the VPR as a whole; A.8.1.3.3.5. Also achieve > 99.0 per cent vaporisation of 30 nm tetracontane (CH3(CH2)38CH3) particles, with an inlet concentration of ≥ 10,000 cm-3, by means of heating and reduction of partial pressures of the tetracontane. A.8.1.3.4. The PNC shall: A.8.1.3.4.1. Operate under full flow operating conditions; A.8.1.3.4.2. Have a counting accuracy of ± 10 per cent across the range 1 cm-3 to the upper threshold of the single particle count mode of the PNC against a traceable standard. At concentrations below 100 cm-3 measurements averaged over extended sampling periods may be required to demonstrate the accuracy of the PNC with a high degree of statistical confidence; A.8.1.3.4.3. Have a readability of at least 0.1 particle cm-3 at concentrations below 100 cm-3; A.8.1.3.4.4. Have a linear response to particle concentrations over the full measurement range in single particle count mode; A.8.1.3.4.5. Have a data reporting frequency equal to or greater than 0.5 Hz; A.8.1.3.4.6. Have a t90 response time over the measured concentration range of less than 5 s; A.8.1.3.4.7. Incorporate a coincidence correction function up to a maximum 10 per cent correction, and may make use of an internal calibration factor as determined in paragraph A.8.2.1.3., but shall not make use of any other algorithm to correct for or define the counting efficiency; A.8.1.3.4.8. Have counting efficiencies at particle sizes of 23 nm (±1 nm) and 41 nm (±1 nm) electrical mobility diameter of 50 per cent (±12 per cent) and > 90 per cent respectively. These counting efficiencies may be achieved by internal (for example; control of instrument design) or external (for example; size pre-classification) means; A.8.1.3.4.9. If the PNC makes use of a working liquid, it shall be replaced at the frequency specified by the instrument manufacturer. A.8.1.3.5. Where they are not held at a known constant level at the point at which PNC flow rate is controlled, the pressure and/or temperature at inlet to the PNC shall be measured and reported for the purposes of correcting particle concentration measurements to standard conditions. A.8.1.3.6. The sum of the residence time of the PTS, VPR and OT plus the t90 response time of the PNC shall be no greater than 20 s. A.8.1.3.7. The transformation time of the entire particle number sampling system (PTS, VPR, OT and PNC) shall be determined by aerosol switching directly at the inlet of the PTS. The aerosol switching shall be done in less than 0.1 s. The aerosol used for the test shall cause a concentration change of at least 60 per cent full scale (FS).
The concentration trace shall be recorded. For time alignment of the particle number concentration and exhaust flow signals, the transformation time is defined as the time from the change (t0) until the response is 50 per cent of the final reading (t50). A.8.1.4. Recommended system description The following paragraph contains the recommended practice for measurement of particle number. However, any system meeting the performance specifications in paragraphs A.8.1.2. and A.8.1.3. is acceptable. Figures 19 and 20 are schematic drawings of the recommended particle sampling system configures for partial and full flow dilution systems respectively.
Annex 5 — Specifications of reference fuels
Technical data on fuels for testing compression-ignition engines Type: Diesel (B7)
Parameter Unit Limit1 Test method
Minimum Maximum
Cetane index 46.0 EN ISO 4264 Cetane number 52.0 56.0 EN-ISO 5165 Density at 15 °C kg/m 833 837 EN-ISO 3675 EN ISO 12185 Distillation:
- 50 % point °C 245 EN-ISO 3405
- 95 % point °C 345 350 EN-ISO 3405
- final boiling point °C 360 EN-ISO 3405 Flash point °C 55 EN 22719 CFPP °C 5 EN 116 Viscosity at 40 °C mm /s 2.3 3.3 EN-ISO 3104 Polycyclic aromatic % m/m 2.0 4.0 EN 12916 hydrocarbons Sulphur content mg/kg 10 EN ISO 20846 / EN ISO 20884 Copper corrosion Rating Class 1 EN-ISO 2160 (3h at 50 °C) Conradson carbon residue % m/m 0.2 EN-ISO 10370 (10 % DR) Ash content % m/m 0.01 EN-ISO 6245 Total contamination mg/kg 24 EN 12662 Water content % m/m 0.02 EN-ISO 12937 Neutralisation (strong acid) mg KOH/g 0.10 ASTM D 974 number Oxidation stability3 mg/ml 0.025 EN-ISO 12205 Lubricity (HFRR wear scan µm 400 EN ISO 12156 diameter at 60 °C) Oxidation stability at H 20.0 EN 15751 110 °C3 FAME4 % v/v 6.0 7.0 EN 14078
Notes: The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 Petroleum products – Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied. The range for cetane number is not in accordance with the requirements of a minimum range of 4R. However, in the case of a dispute between fuel supplier and fuel user, the terms of ISO 4259 may be used to resolve such disputes provided replicate measurements, of sufficient number to archive the necessary precision, are made in preference to single determinations. Even though oxidation stability is controlled, it is likely that shelf life will be limited. Advice shall be sought from the supplier as to storage conditions and life. FAME content to meet the specification of EN 14214.
Annex 5
Type: Ethanol for dedicated compression ignition engines (ED95) 1
Parameter Unit Limits2 Test method3
Minimum Maximum
Total alcohol (Ethanol incl. content % m/m 92.4 EN 15721 on higher saturated alcohols) Other higher saturated mono-alcohols % m/m 2.0 EN 15721 (C3-C5) Methanol % m/m 0.3 EN 15721 Density 15ºC kg/m 793.0 815.0 EN ISO 12185
Acidity, calculated as acetic acid % m/m 0.0025 EN 15491 Appearance Bright and clear Flashpoint ºC 10 EN 3679 Dry residue mg/kg 15 EN 15691 Water content % m/m 6.5 EN 154894 EN-ISO 12937 EN15692 Aldehydes calculated as acetaldehyde % m/m 0.0050 ISO 1388-4 Esters calculated as ethylacetat % m/m 0.1 ASTM D1617 Sulphur content mg/kg 10.0 EN 15485 EN 15486 Sulphates mg/kg 4.0 EN 15492 Particulate contamination mg/kg 24 EN 12662 Phosphorus mg/l 0.20 EN 15487 Inorganic chloride mg/kg 1.0 EN 15484 or EN 15492 Copper mg/kg 0.100 EN 15488 Electrical Conductivity µS/cm 2.50 DIN 51627-4 or prEN 15938 Notes: Additives, such as cetane improver as specified by the engine manufacturer, may be added to the ethanol fuel, as long as no negative side effects are known. If these conditions are satisfied, the maximum allowed amount is 10 % m/m. The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 Petroleum products – Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied. Equivalent EN/ISO methods will be adopted when issued for properties listed above. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of EN 15489 shall be applied.
Technical data on fuels for testing positive ignition engines Type: Petrol (E10) Parameter Unit Limits1 Test method2
Minimum Maximum
Research octane number, RON 95.0 97.0 EN ISO 5164:20053 Motor octane number, MON 84.0 86.0 EN ISO 5163:20053 Density at 15 °C kg/m3 743 756 EN ISO 3675 EN ISO 12185 Vapour pressure kPa 56.0 60.0 EN ISO 13016-1 (DVPE) Water content % v/v 0.015 ASTM E 1064 Distillation:
- evaporated at 70 °C % v/v 24.0 44.0 EN-ISO 3405
- evaporated at 100 °C % v/v 56.0 60.0 EN-ISO 3405
- evaporated at 150 °C % v/v 88.0 90.0 EN-ISO 3405
- final boiling point °C 190 210 EN-ISO 3405 Residue % v/v — 2.0 EN-ISO 3405 Hydrocarbon analysis:
- olefins % v/v 3.0 18.0 EN 14517 EN 15553
- aromatics % v/v 25.0 35.0 EN 14517 EN 15553
- benzene % v/v 0.4 1.0 EN 12177 EN 238, EN 14517
- saturates % v/v Report EN 14517 EN 15553 Carbon/hydrogen ratio Report Carbon/oxygen ratio Report Induction period minutes 480 EN-ISO 7536 Oxygen content % m/m 3.7 EN 1601 EN 13132 EN 14517 Existent gum mg/ml — 0.04 EN-ISO 6246 Sulphur content mg/kg — 10 EN ISO 20846 EN ISO 20884 Copper corrosion (3h at 50 °C) rating — Class 1 EN-ISO 2160 Lead content mg/l — 5 EN 237 Phosphorus content mg/l — 1.3 ASTM D 3231 Ethanol % v/v 9.5 10.0 EN 1601 EN 13132 EN 14517
Annex 5
Notes: The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 Petroleum products - Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied. Equivalent EN/ISO methods will be adopted when issued for properties listed above. A correction factor of 0.2 for MON and RON shall be subtracted for the calculation of the final result in accordance with EN 228:2008. The fuel may contain oxidation inhibitors and metal deactivators normally used to stabilise refinery gasoline streams, but detergent/dispersive additives and solvent oils shall not be added. Ethanol meeting the specification of EN 15376 is the only oxygenate that shall be intentionally added to the reference fuel. The actual sulphur content of the fuel used for the Type 1 test shall be reported. There shall be no intentional addition of compounds containing phosphorus, iron, manganese, or lead to this reference fuel.
Type: Ethanol (E85)
Parameter Unit Limits1 Test method
Minimum Maximum
Research octane number, 95.0 — EN ISO 5164 RON Motor octane number, 85.0 — EN ISO 5163 MON Density at 15 oC kg/m3 Report ISO 3675 Vapour pressure kPa 40.0 60.0 EN ISO 13016-1 (DVPE) Sulphur content2 mg/kg — 10 EN 15485 or EN 15486 Oxidation stability Minutes 360 EN ISO 7536 Existent gum content mg/100ml — 5 EN-ISO 6246 (solvent washed) Appearance Clear and bright, visibly free of Visual inspection This shall be determined at suspended or precipitated ambient temperature or contaminants 15°C whichever is higher Ethanol and higher % v/v 83 85 EN 1601 alcohols3 EN 13132 EN 14517 E DIN 51627-3 Higher alcohols (C3-C8) % v/v — 2.0 E DIN 51627-3 Methanol % v/v 1.00 E DIN 51627-3 Petrol % v/v Balance EN 228 Phosphous mg/l 0.20 EN 15487 Water content % v/v 0.300 EN 15489 or EN 15692 Inorganic chloride content mg/l 1 EN 15492 pHe 6.5 9.0 EN 15490 Copper strip corrosion Rating Class 1 EN ISO 2160 (3h at 50°C) Acidity, (as acetic acid % m/m — 0.0050 EN 15491 CH3COOH) (mg/l) (40) Electric Conductivity µS/cm 1.5 DIN 51627-4 or prEN 15938 Carbon/hydrogen ratio report Carbon/oxygen ration report
Annex 5
Notes: The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 Petroleum products - Determination and application of precision data in relation to methods of test have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels shall nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify whether a fuel meets the requirements of the specifications, the terms of ISO 4259 shall be applied. The actual sulphur content of the fuel used for the emission tests shall be reported. Ethanol to meet specification of EN 15376 is the only oxygenate that shall be intentionally added to this reference fuel. The unleaded petrol content can be determined as 100 minus the sum of the percentage content of water, alcohols, MTBE and ETBE. There shall be no intentional addition of compounds containing phosphorus, iron, manganese, or lead to this reference fuel.
Type: LPG
Parameter Unit Fuel A Fuel B Test method
Composition: EN 27941 C3-content % v/v 30 ± 2 85 ± 2 C4-content % v/v Balance Balance1 < C3 , > C4 % v/v Maximum 2 Maximum 2 Olefins % v/v Maximum 12 Maximum 15 Evaporation residue mg/kg Maximum 50 Maximum 50 EN 15470 Water at 0 °C Free Free EN 15469 Total sulphur content mg/kg Maximum 10 Maximum 10 EN 24260, including odorant ASTM D 3246, ASTM Hydrogen sulphide None None EN ISO 8819 Copper strip corrosion Rating Class 1 Class 1 ISO 62512 (1h at 40 °C) Odour Characteristic Characteristic Motor octane number Minimum 89.0 Minimum 89.0 EN 589 Annex B Notes: Balance shall be read as follows: balance = 100 - C3 - <C3 - >C4. This method may not accurately determine the presence of corrosive materials if the sample contains corrosion inhibitors or other chemicals which diminish the corrosivity of the sample to the copper strip. Therefore, the addition of such compounds for the sole purpose of biasing the test method is prohibited. At the request of the engine manufacturer, a higher MON could be used to perform the type approval tests.
Annex 5
Type: Natural Gas/ Biomethane
Characteristics Units Basis Limits Test method
minimum maximum
Reference fuel GR Composition: Methane 87 84 89 Ethane 13 11 15 Balance % mole — — 1 ISO 6974 Sulphur content mg/m — 10 ISO 6326-5
Notes: Inerts + C2+ Value to be determined at standard conditions 293.2 K (20 °C) and 101.3 kPa. Reference fuel G23 Composition: Methane 92.5 91.5 93.5 Balance % mole — — 1 ISO 6974 N2 % mole 7.5 6.5 8.5 Sulphur content mg/m — — 10 ISO 6326-5
Notes: Inerts (different from N2) + C2+ C2+ Value to be determined at 293.2 K (20 °C) and 101.3 kPa. Reference fuel G25 Composition: Methane % mole 86 84 88 Balance % mole — — 1 ISO 6974 N2 % mole 14 12 16 Sulphur content mg/m — — 10 ISO 6326-5
Notes: Inerts (different from N2) + C2+ C2+ Value to be determined at 293.2 K (20 °C) and 101.3 kPa.
Annex 6 — Emissions data required at type approval for roadworthiness
purposes
Measuring carbon monoxide emissions at idling speeds
1.Introduction
This annex sets out the procedure for measuring carbon monoxide emissions at idling speeds (normal and high) for positive ignition engines fuelled with petrol or ethanol (E85) or positive ignition engines fuelled with NG/Biomethane or LPG installed in M2, N1 or M1 vehicles with a maximum permissible mass not exceeding 7.5 tonnes.
2.General requirements
The general requirements shall be those set out in paragraph 5.3.7. of Regulation No. 83, with the exceptions set out in paragraphs 2.2., 2.3. and 2.4.
The atomic ratios set out in paragraph 5.3.7.3. of Regulation No. 83 shall be understood as follows:
Hcv = Atomic ratio of – for petrol (E10) 1.93 hydrogen to
– for LPG 2.525 carbon
– for NG/biomethane 4.0
– for ethanol (E85) 2.74
Ocv = Atomic ratio of – for petrol (E10) 0.032 oxygen to carbon
– for LPG 0.0
– for NG/biomethane 0.0
– for ethanol (E85) 0.385
The table in paragraph 1.4.3. of Annex 2A (Table 6) shall be completed on the basis of the requirements set out in paragraphs 2.2. and 2.4. of this annex.
The manufacturer shall confirm the accuracy of the Lambda value recorded at the time of type approval in paragraph 2.1. of this annex as being representative of typical production vehicles within 24 months of the date of the granting of type approval. An assessment shall be made on the basis of surveys and studies of production vehicles.
3.Technical requirements
The technical requirements shall be those set out in Annex 5 to Regulation No. 83, with the exception set out in paragraph 3.2.
The reference fuels specified in paragraph 2.1. of Annex 5 to Regulation No. 83 shall be understood as referring to the appropriate reference fuel specifications set out in Annex 5 to this Regulation.
Annex 7
Annex 7 — Verifying the durability of engine systems
1.Introduction
This annex sets out the procedures for selecting engines to be tested over a service accumulation schedule for the purpose of determining deterioration factors. The deterioration factors shall be applied in accordance with the requirements of paragraph 3.6. of this annex to the emissions measured according to Annex 4.
This annex also sets out the emission and non-emission-related maintenance carried out on engines undergoing a service accumulation schedule. Such maintenance shall conform to the maintenance performed on in-service engines and shall be communicated to owners of new engines and vehicles.
2.Selection of engines for establishing useful life deterioration factors
Engines shall be selected from the engine family defined in accordance with paragraph 7. of this Regulation for emission testing in order to establish useful life deterioration factors.
Engines from different engine families may be further combined into families based on the type of exhaust after-treatment system utilised. In order to place engines with different numbers of cylinders and different cylinder configuration but having the same technical specifications and installation for the exhaust after-treatment systems into the same engine-after-treatment system family, the manufacturer shall provide data to the Type Approval Authority that demonstrates that the emissions reduction performance of such engine systems is similar.
One engine representing the engine-after-treatment system family as determined in accordance with paragraph 2.2., shall be selected by the engine manufacturer for testing over the service accumulation schedule defined in paragraph 3.2., and shall be reported to the Type Approval Authority before any testing commences.
If the Type Approval Authority decides that the worst case emissions of the engine-after-treatment system family can be characterised better by another engine then the test engine shall be selected jointly by the Type Approval Authority and the engine manufacturer.
3.Establishing useful life deterioration factors
General
Deterioration factors applicable to an engine-after-treatment system family are developed from the selected engines based on a service accumulation schedule that includes periodic testing for gaseous and particulate emissions over the WHTC and WHSC tests.
Service accumulation schedule
Service accumulation schedules may be carried out at the choice of the manufacturer by running a vehicle equipped with the selected engine over an in-service accumulation schedule or by running the selected engine over a dynamometer service accumulation schedule.
In-service and dynamometer service accumulation
The manufacturer shall determine the form and extent of the distance, the service accumulation and the ageing cycle for engines, consistent with good engineering practice.
The manufacturer shall determine the test points where gaseous and particulate emissions will be measured over the hot WHTC and WHSC tests. The minimum number of test points shall be three, one at the beginning, one approximately in the middle and one at the end of the service accumulation schedule.
The emission values at the start point and at the useful life end point calculated in accordance with paragraph 3.5.2. shall meet the limit values specified in paragraph 5.3. of this Regulation but individual emission results from the test points may exceed those limit values.
At the request of the manufacturer and with the agreement of the Type
Approval Authority, only one test cycle (either the hot WHTC or WHSC test) needs to be run at each test point, with the other test cycle run only at the beginning and at the end of the service accumulation schedule.
Service accumulation schedules may be different for different engine-after- treatment system families.
Service accumulation schedules may be shorter than the useful life period, but shall not be shorter than shown in Table 1 in paragraph 3.2.1.8.
For engine dynamometer service accumulation, the manufacturer shall provide the applicable correlation between the service accumulation period (driving distance) and engine dynamometer hours, for example, fuel consumption correlation, vehicle speed versus engine revolutions correlation etc.
Annex 7
Minimum service accumulation period
Minimum service accumulation period
Category of vehicle in which engine will be installed1 Minimum service Useful life accumulation period Category N1 vehicles 160,000 km See paragraph 5.4. of this Regulation Category N2 vehicles 188,000 km See paragraph 5.4. of this Regulation Category N3 vehicles with a maximum technically 188,000 km See paragraph 5.4. permissible mass not exceeding 16 tonnes of this Regulation Category N3 vehicles with a maximum 233,000 km See paragraph 5.4. technically permissible mass exceeding 16 tonnes of this Regulation Category M1 vehicles 160,000 km See paragraph 5.4. of this Regulation Category M2 vehicles 160,000 km See paragraph 5.4. of this Regulation Category M3 vehicles of classes I, II, A and B 188,000 km See paragraph 5.4. with a maximum technically permissible mass not of this Regulation exceeding 7.5 tonnes Category M3 vehicles of classes III and B with a 233,000 km See paragraph 5.4. maximum technically permissible mass exceeding of this Regulation 7.5 tonnes
Accelerated ageing is permitted by adjusting the service accumulation schedule on a fuel consumption basis. The adjustment shall be based on the ratio between the typical in-use fuel consumption and the fuel consumption on the ageing cycle, but the fuel consumption on the ageing cycle shall not exceed the typical in-use fuel consumption by more than 30 per cent.
The service accumulation schedule shall be fully described in the application for type approval and reported to the Type Approval Authority before the start of any testing.
If the Type Approval Authority decides that additional measurements need to be carried out on the hot WHTC and WHSC tests between the points selected by the manufacturer it shall notify the manufacturer. The revised service accumulation schedule shall be prepared by the manufacturer and agreed by the Type Approval Authority.
Engine testing
Engine system stabilisation
For each engine-after-treatment system family, the manufacturer shall determine the number of hours of vehicle or engine running after which the operation of the engine-after-treatment system has stabilised. If requested by the Type Approval
As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3) - ECE/TRANS/WP.29/78/Rev.2, para.2.
Authority the manufacturer shall make available the data and analysis used to make this determination. As an alternative, the manufacturer may elect to run the engine between 60 and 125 hours or the equivalent mileage on the ageing cycle to stabilise the engine-after-treatment system.
The end of the stabilisation period determined in paragraph 3.3.1.1. will be deemed to be the start of the service accumulation schedule.
Service accumulation testing
After stabilisation, the engine shall be run over the service accumulation schedule selected by the manufacturer, as described in paragraph 3.2. At the periodic intervals in the service accumulation schedule determined by the manufacturer, and, where appropriate, also stipulated by the Type Approval Authority according to paragraph 3.2.2. the engine shall be tested for gaseous and particulate emissions over the hot WHTC and WHSC tests. In accordance with paragraph 3.2.1.4., if it has been agreed that only one test cycle (hot WHTC or WHSC) be run at each test point, the other test cycle (hot WHTC or WHSC) shall be run at the beginning and end of the service accumulation schedule.
During the service accumulation schedule, maintenance shall be carried out on the engine according to the requirements of paragraph 4.
During the service accumulation schedule, unscheduled maintenance on the engine or vehicle may be performed, for example if the OBD system has specifically detected a problem that has resulted in the malfunction indicator (hereinafter MI) being activated.
Reporting
The results of all emission tests (hot WHTC and WHSC) conducted during the service accumulation schedule shall be made available to the Type Approval Authority. If any emission test is declared to be void, the manufacturer shall provide an explanation of why the test has been declared void. In such a case, another series of emission tests over the hot WHTC and WHSC tests shall be carried out within the following 100 hours of service accumulation.
The manufacturer shall retain records of all information concerning all the emission tests and maintenance carried out on the engine during the service accumulation schedule. This information shall be submitted to the Type Approval Authority along with the results of the emission tests conducted over the service accumulation schedule.
Determination of deterioration factors
For each pollutant measured on the hot WHTC and WHSC tests at each test point during the service accumulation schedule, a "best fit" linear regression analysis shall be made on the basis of all test results. The results of each test for each pollutant shall be expressed to the same number of decimal places as the limit value for that pollutant, as shown in paragraph 5.3. of this Regulation, plus one additional decimal place. In accordance with paragraph 3.2.1.4. of this annex, if it has been agreed that only one test cycle (hot WHTC or WHSC) be run at each test point and the other test cycle (hot WHTC or WHSC) run only at the beginning and at the end of the service accumulation schedule, the regression analysis shall be made only on the basis of the test results from the test cycle run at each test point. At the request of the manufacturer and with the prior approval of the Type Approval Authority a non linear regression shall be permitted.
Annex 7
The emission values for each pollutant at the start of the service accumulation schedule and at the useful life end point that is applicable for the engine under test shall be calculated from the regression equation. If the service accumulation schedule is shorter than the useful life period, the emission values at the useful life end point shall be determined by extrapolation of the regression equation as determined in paragraph 3.5.1.
The deterioration factor for each pollutant is defined as the ratio of the applied emission values at the useful life end point and at the start of the service accumulation schedule (multiplicative deterioration factor). At the request of the manufacturer and with the prior approval of the Type Approval Authority, an additive deterioration factor for each pollutant may be applied. The additive deterioration factor shall be considered as the difference between the calculated emission values at the useful life end point and at the start of the service accumulation schedule. If the calculation results in a value of less than 1.00 for a multiplicative DF, or less than 0.00 for an additive DF, then the deterioration factor shall be 1.0 or 0.00, respectively. An example for determination of deterioration factors by using linear regression is shown in Figure 1. Mixing of multiplicative and additive deterioration factors within one set of pollutants shall not be permitted. In accordance with paragraph 3.2.1.4., if it has been agreed that only one test cycle (hot WHTC or WHSC) be run at each test point and the other test cycle (hot WHTC or WHSC) run only at the beginning and end of the service accumulation schedule, the deterioration factor calculated for the test cycle that has been run at each test point shall be applicable also for the other test cycle.
Assigned deterioration factors
As an alternative to using a service accumulation schedule to determine deterioration factors, engine manufacturers may choose to use the following assigned multiplicative deterioration factors:
Deterioration factors
Test cycle CO THC1 NMHC2 CH42 NOx NH3 PM PM
mass number
WHTC 1.3 1.3 1.4 1.4 1.15 1.0 1.05 1.0
WHSC 1.3 1.3 1.4 1.4 1.15 1.0 1.05 1.0
Notes:
Applies in case of a compression ignition engine.
Applies in case of a positive ignition engine.
Assigned additive deterioration factors are not given. It shall not be permitted
to transform the assigned multiplicative deterioration factors into additive
deterioration factors.Application of deterioration factors
The engines shall meet the respective emission limits for each pollutant, as given in paragraph 5.3. of this Regulation, after application of the deterioration factors to the test result as measured in accordance with Annex 4 (egas, ePM). Depending on the type of deterioration factor (DF), the following provisions shall apply:
(a) Multiplicative: (egas or ePM) * DF ≤ emission limit;
(b) Additive: (egas or ePM) + DF ≤ emission limit.
The manufacturer may choose to carry across the DFs determined for an engine after treatment system family to an engine system that does not fall into the same engine-after-treatment system family. In such cases, the manufacturer shall demonstrate to the Type Approval Authority that the engine system for which the after-treatment system family was originally tested and the engine system for which the DFs are being carried across have the same technical specifications and installation requirements on the vehicle and that the emissions of such engine or engine system are similar.
The deterioration factors for each pollutant on the appropriate test cycle shall be recorded in paragraphs 1.4.1. and 1.4.2. of the Addendum to Annex 2A and in paragraphs 1.4.1. and 1.4.2. of the Addendum to Annex 2C.
Checking of conformity of production
Conformity of production for emissions compliance shall be checked on the basis of the requirements of paragraph 8. of this Regulation.
The manufacturer may choose to measure the pollutant emissions before any exhaust after-treatment system at the same time as the type approval test is being performed. In doing so, the manufacturer may develop an informal deterioration factor separately for the engine and the after-treatment system that may be used by the manufacturer as an aid to end of production line auditing.
Annex 7
For the purposes of type approval, only the deterioration factors according to paragraphs 3.5. or 3.6. shall be recorded in paragraphs 1.4.1. and 1.4.2. of the Addendum to Annex 2A and paragraphs 1.4.1. and 1.4.2. of the Addendum to Annex 2C.
4.Maintenance
For the purpose of the service accumulation schedule, maintenance shall be performed in accordance with the manufacturer’s manual for service and maintenance.
Emission-related scheduled maintenance
Emission-related scheduled maintenance for purposes of conducting a service accumulation schedule shall occur at the same distance or equivalent intervals to those that will be specified in the manufacturer’s maintenance instructions to the owner of the engine or vehicle. This maintenance schedule may be updated as necessary throughout the service accumulation schedule provided that no maintenance operation is deleted from the maintenance schedule after the operation has been performed on the test engine.
The engine manufacturer shall specify for the service accumulation schedule the adjustment, cleaning and maintenance (where necessary) and scheduled exchange of the following items:
(a) Filters and coolers in the exhaust gas re-circulation system;
(b) Positive crankcase ventilation valve, if applicable;
(c) Fuel injector tips (cleaning only);
(d) Fuel injectors;
(e) Turbocharger;
(f) Electronic engine control unit and its associated sensors and actuators;
(g) Particulate after-treatment system (including related components);
(h) deNOx system;
(i) Exhaust gas re-circulation system, including all related control valves and tubing;
(j) Any other exhaust after-treatment system.
Critical emission-related scheduled maintenance shall only be performed if being performed in-use and being communicated to the owner of the vehicle.
Changes to scheduled maintenance
The manufacturer shall submit a request to the Type Approval Authority for approval of any new scheduled maintenance that it wishes to perform during the service accumulation schedule and subsequently recommend to owners of engines.or vehicles. The request shall be accompanied by data supporting the need for the new scheduled maintenance and the maintenance interval.
Non-emission-related scheduled maintenance
Non-emission-related scheduled maintenance which is reasonable and technically necessary such as oil change, oil filter change, fuel filter change, air filter change, cooling system maintenance, idle speed adjustment, governor, engine bolt torque, valve lash, injector lash, timing, adjustment of
the tension of any drive-belt, etc may be performed on engines or vehicles selected for the service accumulation schedule at the least frequent intervals recommended by the manufacturer to the owner.
Repair
Repairs to the components of an engine selected for testing over a service accumulation schedule other than the engine emission control system or fuel system shall be performed only as a result of component failure or engine system malfunction.
If the engine itself, the emission control system or the fuel system fail during the service accumulation schedule, the service accumulation shall be considered void, and a new service accumulation shall be started with a new engine system.
Annex 8
Conformity of in-service engines or vehicles
1.Introduction
1.1 This annex sets out requirements for checking and demonstrating the conformity of in-service engines and vehicles.
2.Procedure for in-service conformity
The conformity of in-service vehicles or engines of an engine family shall be demonstrated by testing vehicles on the road operated over their normal driving patterns, conditions and payloads. The in-service conformity test shall be representative for vehicles operated on their real driving routes, with their normal load and with the usual professional driver of the vehicle. When the vehicle is operated by a driver other than the usual professional driver of the particular vehicle, this alternative driver shall be skilled and trained to operate vehicles of the category subject to be tested.
If the normal in-service conditions of a particular vehicle are considered to be incompatible with the proper execution of the tests, the manufacturer or the Type Approval Authority may request that alternative driving routes and payloads are used.
The manufacturer shall demonstrate to the Type Approval Authority that the chosen vehicle, driving patterns, conditions and payloads are representative for the engine family. The requirements as specified in paragraphs 4.1. and
shall be used to determine whether the driving patterns and payloads are acceptable for in-service conformity testing.
The manufacturer shall report the schedule and the sampling plan for conformity testing at the time of the initial type approval of a new engine family.
Vehicles without a communication interface which permits the collection of the necessary ECU data as specified in paragraphs 9.4.2.1. and 9.4.2.2. of this Regulation, with missing data or with a non-standard data protocol shall be considered as non compliant.
Vehicles where the collection of ECU data influences the vehicle emissions or performance shall be considered as non compliant.
3.Engine or vehicle selection
After the granting of type approval for an engine family the manufacturer shall perform in-service testing on this engine family within 18 months from first registration of a vehicle fitted with an engine from that family. In case of multistage type approval first registration means first registration of a completed vehicle. The testing shall be repeated at least every two years for each engine family periodically on vehicles over their useful life period as specified in paragraph 5.4. of this Regulation.
At the request of the manufacturer the testing may stop five years after the end of production.
With a minimum sample size of three engines the sampling procedure shall be set so that the probability of a lot passing a test with 20 per cent of the vehicles or engines defective is 0.90 (producer's risk = 10 per cent) while the probability of a lot being accepted with 60 per cent of the vehicles or engines defective is 0.10 (consumer's risk = 10 per cent).
The test statistic quantifying the cumulative number of nonconforming tests at the n-th test shall be determined for the sample.
The pass or fail decision of the lot shall be made according to the following requirements:
(a) If the test statistic is less than or equal to the pass decision number for the sample size given in Table 1, a pass decision is reached for the lot;
(b) If the test statistic is greater than or equal to the fail decision number for the sample size given in Table 1, a fail decision is reached for the lot;
(c) Otherwise, an additional engine is tested according to this annex and the calculation procedure is applied to the sample increased by one more unit. In Table 1 the pass and fail decision numbers are calculated by means of the International Standard ISO 8422/1991.
Pass and fail decision numbers of the sampling plan
Minimum sample size: 3
Cumulative number of
engines tested Pass decision number Fail decision number
(sample size)
3 - 3
4 0 4
5 0 4
6 1 4
7 1 4
8 2 4
9 2 4
10 3 4
The Type Approval Authority shall approve the selected engines and vehicle
configurations before the launch of the testing procedures. The selection shall
be performed by presenting to the Type Approval Authority the criteria used
for the selection of the particular vehicles.The engines and vehicles selected shall be used and registered in the region (e.g. European Union). The vehicle shall have been in service for at least 25,000 km.
Annex 8
Each vehicle tested shall have a maintenance record to show that the vehicle has been properly maintained and serviced in accordance with the manufacturer's recommendations.
The OBD system shall be checked for proper functioning of the engine. Any malfunction indications and the readiness code in the OBD memory shall be recorded and any required repairs shall be carried out. Engines presenting a Class C malfunction shall not be forced to be repaired before testing. The Diagnostic Trouble Code (DTC) shall not be cleared. Engines having one of the counters required by provisions of Annex 11 not at "0" may not be tested. This shall be reported to the Type Approval Authority.
The engine or vehicle shall exhibit no indications of abuse (such as overloading, misfuelling, or other misuse), or other factors (such as tampering) that could affect emission performance. OBD system fault code and engine running hours information stored in the computer shall be taken into account.
All emission control system components on the vehicle shall be in conformity with those stated in the applicable type approval documents.
In agreement with the Type Approval Authority, the manufacturer may run in-service conformity testing comprising fewer engines or vehicles than the number given in paragraph 3.1., if the number of engines manufactured within an engine family is less than 500 units per year.
4.Test conditions
Vehicle payload
For the purpose of in- service conformity testing the payload may be reproduced and an artificial load may be used. In the absence of statistics to demonstrate that the payload is representative for the vehicle, the vehicle payload shall be 50 - 60 per cent of the maximum vehicle payload. The maximum payload is the difference between technically permissible maximum laden mass of the vehicle and the mass of the vehicle in running order as specified in Annex 3 to Special Resolution No.1 (TRANS/WP.29/1045).
Ambient conditions
The test shall be conducted under ambient conditions meeting the following conditions: Atmospheric pressure greater than or equal to 82.5 kPa, Temperature greater than or equal to 266 K (-7°C) and less than or equal to the temperature determined by the following equation at the specified atmospheric pressure: T = -0.4514 * (101.3 – pb) + 311 Where: T is the ambient air temperature, K pb is the atmospheric pressure, kPa
Engine coolant temperature
The engine coolant temperature shall be in accordance with paragraph A.1.2.6.1. of Appendix 1 to this annex.
The lubricating oil, fuel and reagent shall be within the specifications issued by the manufacturer.
Lubricating oil
Oil samples shall be taken.
Fuel
The test fuel shall be market fuel covered by the relevant standards or reference fuel as specified in Annex 5 to this Regulation. Fuel samples shall be taken.
If the manufacturer in accordance with paragraph 4. to this Regulation has declared the capability to meet the requirements of this Regulation on market fuels declared in paragraph 3.2.2.2.1. of Part 1 of Annex 1 to this Regulation, tests shall be conducted on at least one of the declared market fuels or blend between the declared market fuels and the market fuels covered by the relevant standards.
Reagent
For exhaust after-treatment systems that use a reagent to reduce emissions, a sample of the reagent shall be taken. The reagent shall not be frozen.
Trip requirements
The shares of operation shall be expressed as a percentage of the total trip duration. The trip shall consist of urban driving followed by rural and motorway driving according to the shares specified in paragraphs 4.5.1. to 4.5.4. In the case another testing order is justified for practical reasons and after the agreement of the Type Approval Authority another order of urban, rural and motorway operation may be used. For the purpose of this paragraph, "approximately" shall mean the target value ±5 per cent. Urban operation is characterised by vehicle speeds between 0 and 50 km/h, Rural operation is characterised by vehicle speeds between 50 and 75 km/h, Motorway operation is characterised by vehicle speeds above 75 km/h.
For M1 and N1 vehicles the trip shall consist of approximately 45 per cent urban, 25 per cent rural and 30 per cent motorway operation.
For M2 and M3 vehicles the trip shall consist of approximately 45 per cent urban, 25 per cent rural and 30 per cent motorway operation. M2 and M3 vehicles of Class I, II or Class A shall be tested in approximately 70 per cent urban and 30 per cent rural operation.
For N2 vehicles the trip shall consist of approximately 45 per cent urban, 25 per cent rural and followed by 30 per cent motorway operation.
For N3 vehicles the trip shall consist of approximately 20 per cent urban, 25 per cent rural and followed by 55 per cent motorway operation.
Annex 8
4.5.5 The following distribution of the characteristic trip values from the WHDC database may serve as additional guidance for the evaluation of the trip:
(a) Accelerating: 26.9 per cent of the time;
(b) Decelerating: 22.6 per cent of the time;
(c) Cruising: 38.1 per cent of the time;
(d) Stop (vehicle speed=0): 12.4 per cent of the time.
Operational requirements
The trip shall be selected in such a way that the testing is uninterrupted and the data continuously sampled to reach the minimum test duration defined in paragraph 4.6.5.
Emissions and other data sampling shall start prior to starting the engine. Any cold start emissions may be removed from the emissions evaluation, in accordance with paragraph A.1.2.6. of Appendix 1 to this annex.
It shall not be permitted to combine data of different trips or to modify or remove data from a trip.
If the engine stalls, it may be restarted, but the sampling shall not be interrupted.
The minimum test duration shall be long enough to complete five times the work performed during the WHTC or produce five times the CO 2 reference mass in kg/cycle from the WHTC as applicable.
The electrical power to the PEMS system shall be supplied by an external power supply unit, and not from a source that draws its energy either directly or indirectly from the engine under test.
The installation of the PEMS equipment shall not influence the vehicle emissions and/or performance.
It is recommended to operate the vehicles under normal daytime traffic conditions.
If the Type Approval Authority is not satisfied with the data consistency check results according to paragraph A.1.3.2. of Appendix 1 to this annex, the Type Approval Authority may consider the test to be void.
The same route shall be used for the tests of vehicles within the sample described in paragraphs 3.1.1. to 3.1.3.
5.ECU data stream
Verification of the availability and conformity of the ECU data-stream information required for in-service testing.
The availability of the data stream information according to the requirements of paragraph 9.4.2. of this Regulation shall be demonstrated prior to the in- service test.
If that information cannot be retrieved by the PEMS system in a proper manner, the availability of the information shall be demonstrated by using an external OBD scan-tool as described in Annex 9B.
In the case where this information can be retrieved by the scan-tool in a proper manner, the PEMS system is considered as failing and the test is void.
In the case where that information cannot be retrieved in a proper manner from two vehicles with engines from the same engine family, while the scan- tool is working properly, the engine is considered as non compliant.
The conformity of the torque signal calculated by the PEMS equipment from the ECU data-stream information required in paragraph 9.4.2.1. of this Regulation shall be verified at full load.
The method used to check this conformity is described in Appendix 4 to this annex.
The conformity of the ECU torque signal is considered to be sufficient if the calculated torque remains within the full load torque tolerance specified in paragraph 9.4.2.5. of this Regulation.
If the calculated torque does not remain within the full load torque tolerance specified in paragraph 9.4.2.5. of this Regulation, the engine is considered to have failed the test.
6.Emissions evaluation
The test shall be conducted and the test results shall be calculated in accordance with the provisions of Appendix 1 to this Annex.
The conformity factors shall be calculated and presented for both the CO2 mass based method and the work based method. The pass/fail decision shall be made on the basis of the results of the work based method.
The 90 per cent cumulative percentile of the exhaust emission conformity factors from each engine system tested, determined in accordance with the measurement and calculation procedures specified in Appendix 1 to this annex, shall not exceed any of the values set out in Table 2.
Maximum allowed conformity factors for in-service conformity emission
testing Pollutant Maximum allowed conformity factor CO 1.50 THC 1.50 NMHC 1.50 CH4 1.50 NOx 1.50 PM mass - PM number -
7.Evaluation of in-service conformity results
On the basis of the in-service conformity report referred to in paragraph 10., the Type Approval Authority shall either:
(a) Decide that the in-service conformity testing of an engine system family is satisfactory and not take any further action;
Annex 8
(b) Decide that the data provided is insufficient to reach a decision and request additional information and test data from the manufacturer;
(c) Decide that the in-service conformity of an engine system family is unsatisfactory and proceed to the measures referred to in paragraph 9.3. of this Regulation and in paragraph 9. of this annex.
8.Confirmatory vehicle testing
Confirmatory testing is done for the purpose of confirmation of the in-service emission functionality of an engine family.
Approval authorities may conduct confirmatory testing.
The confirmatory test shall be performed as vehicle testing as specified in paragraphs 2.1. and 2.2. Representative vehicles shall be selected and used under normal conditions and be tested according to the procedures defined in this annex.
A test result may be regarded as non-satisfactory when, from tests of two or more vehicles representing the same engine family, for any regulated pollutant component, the limit value as determined according to paragraph 6. is exceeded significantly.
9.Plan of remedial measures
The manufacturer shall submit a report to the Type Approval Authority where the engines or vehicles subject to remedial action are registered or used when planning to conduct remedial action, and shall submit this report when deciding to take action. The report shall specify the details of the remedial action and describe the engine families to be included in the action. The manufacturer shall report regularly to the Type Approval Authority after the start of the remedial action.
The manufacturer shall provide a copy of all communications related to the plan of remedial measures, and shall maintain a record of the recall campaign, and supply regular status reports to the Type Approval Authority.
The manufacturer shall assign a unique identifying name or number to the plan of remedial measures.
The manufacturer shall present a plan of remedial measures which shall consist of the information specified in paragraphs 9.4.1. to 9.4.11.
A description of each engine system type included in the plan of remedial measures.
A description of the specific modifications, alterations, repairs, corrections, adjustments, or other changes to be made to bring the engines into conformity including a brief summary of the data and technical studies which support the manufacturer's decision as to the particular measures to be taken to correct the non-conformity.
A description of the method by which the manufacturer informs the engine or vehicle owners about the remedial measures.
A description of the proper maintenance or use, if any, which the manufacturer stipulates as a condition of eligibility for repair under the plan of remedial measures, and an explanation of the manufacturer's reasons for
imposing any such condition. No maintenance or use conditions may be imposed unless it is demonstrably related to the non-conformity and the remedial measures.
A description of the procedure to be followed by engine or vehicle owners to obtain correction of the non-conformity. This description shall include a date after which the remedial measures may be taken, the estimated time for the workshop to perform the repairs and where they can be done. The repair shall be done expediently, within a reasonable time after delivery of the vehicle.
A copy of the information transmitted to the engine or vehicle owner.
A brief description of the system which the manufacturer uses to assure an adequate supply of components or systems for fulfilling the remedial action. It shall be indicated when there will be an adequate supply of components or systems to initiate the campaign.
A copy of all instructions to be sent to those persons who are to perform the repair.
A description of the impact of the proposed remedial measures on the emissions, fuel consumption, driveability, and safety of each engine or vehicle type, covered by the plan of remedial measures with data, technical studies, etc. which support these conclusions.
Any other information, reports or data the Type Approval Authority may reasonably determine is necessary to evaluate the plan of remedial measures.
Where the plan of remedial measures includes a recall, a description of the method for recording the repair shall be submitted to the Type Approval Authority If a label is used, an example of it shall be submitted.
The manufacturer may be required to conduct reasonably designed and necessary tests on components and engines incorporating a proposed change, repair, or modification to demonstrate the effectiveness of the change, repair, or modification.
10.Reporting procedures
A technical report shall be submitted to the Type Approval Authority for each engine family tested. The report shall show the activities and results of the in-service conformity testing. The report shall include at least the following:
General
Name and address of the manufacturer
Address(es) of assembly plant(s)
The name, address, telephone and fax numbers and e-mail address of the manufacturer’s representative
Type and commercial description (mention any variants)
Engine family
Parent engine
Engine family members
The vehicle identification number (VIN) codes applicable to the vehicles equipped with an engine that is part of the in-service conformity check.
Annex 8
Means and location of identification of type, if marked on the vehicle
Category of vehicle
Type of engine: petrol, ethanol (E85), diesel/NG /LPG /ethanol (ED95) (Delete as appropriate)
The numbers of the type approvals applicable to the engine types within the in-service family, including, where applicable, the numbers of all extensions and field fixes/recalls (re-works)
Details of extensions, field fixes/recalls to those type approvals for the engines covered within the manufacturer’s information.
The engine build period covered within the manufacturer’s information (e.g. "vehicles or engines manufactured during the 2014 calendar year").
Engine / Vehicle selection
Vehicle or engine location method
Selection criteria for vehicles, engines, in-service families
Geographical areas within which the manufacturer has collected vehicles
Equipment
PEMS Equipment, brand and type
PEMS calibration
PEMS power supply
Calculation software and version used (e.g. EMROAD 4.0)
Test data
Date and time of test
Location of test including details information about the test route
Weather / ambient conditions (e.g. temperature, humidity, altitude)
Distances covered per vehicle on the test route
Test fuel specifications characteristics
Reagent specification (if applicable)
Lubrication oil specification
Emission test results according to Appendix 1 to this annex
Engine information
Engine fuel type (e.g. diesel, ethanol ED95, NG, LPG, petrol, E85)
Engine combustion system (e.g. compressed ignition or positive ignition)
Type approval number
Engine rebuilt
Engine manufacturer
Engine model
Engine production year and month
Engine identification number
Engine displacement [litres]
Number of cylinders
Engine rated power: [kW @ rpm]
Engine peak torque: [Nm @ rpm]
Idle speed [rpm]
Manufacturer supplied full-load torque curve available (yes/no)
Manufacturer supplied full-load torque curve reference number
DeNOx system (e.g. EGR, SCR)
Type of catalytic converter
Type of Particulate trap
After-treatment modified with respect to type approval? (yes/no)
Engine ECU information (Software calibration number)
Vehicle information
Vehicle owner
Vehicle type (e.g. M3, N3) and application (e.g. rigid or articulated truck, city bus)
Vehicle manufacturer
Vehicle Identification Number
Vehicle registration number and country of registration
Vehicle model
Vehicle production year and month
Transmission type (e.g. manual, automatic or other)
Number of forward gears
Odometer reading at test start [km]
Gross vehicle combination weight rating (GVW) [kg]
Tire size [Not mandatory]
Tail pipe diameter [mm] [Not mandatory]
Number of axles
Fuel tank(s) capacity [litres] [Not mandatory]
Number of fuel tanks [Not mandatory]
Reagent tank(s) capacity [litres] [Not mandatory]
Number of reagent tanks [Not mandatory]
Test route characteristics
Odometer reading at test start [km]
Duration [s]
Annex 8
Average ambient conditions(as calculated from the instantaneous measured data)
Ambient conditions sensor information (type and location of sensors)
Vehicle speed information (for example cumulative speed distribution)
Shares of the time of the trip characterised by urban, rural and motorway operation as described in paragraph 4.5.
Shares of the time of the trip characterised by accelerating, decelerating, cruising and stop as described in paragraph 4.5.5.
Instantaneous measured data
THC concentration [ppm]
CO concentration [ppm]
NOx concentration [ppm]
CO2 concentration [ppm]
CH4 concentration [ppm] for natural gas fuelled engines only
Exhaust gas flow [kg/h]
Exhaust temperature [°C]
Ambient air temperature [°C]
Ambient pressure [kPa]
Ambient humidity [g/kg] [Not mandatory]
Engine torque [Nm]
Engine speed [rpm]
Engine fuel flow [g/s]
Engine coolant temperature [°C]
Vehicle ground speed [km/h] from ECU and GPS
Vehicle latitude [degree] (Accuracy needs to be sufficient to enable the traceability of the test route)
Vehicle longitude [degree]
Instantaneous calculated data
THC mass [g/s]
CO mass [g/s]
NOx mass [g/s]
CO2 mass [g/s]
CH4 mass [g/s] for P.I. engines only
THC cumulated mass [g]
CO cumulated mass [g]
NOx cumulated mass [g]
CO2 cumulated mass [g]
CH4 cumulated mass [g] for natural gas fuelled engines only
Calculated fuel rate[g/s]
Engine power [kW]
Engine work [kWh]
Work window duration [s]
Work window average engine power [%]
Work window THC conformity factor [-]
Work window CO conformity factor [-]
Work window NOx conformity factor [-]
Work window CH4 conformity factor [-] for natural gas fuelled engines only
CO2 mass window duration [s]
CO2 mass window THC conformity factor [-]
CO2 mass window CO conformity factor [-]
CO2 mass window NOx conformity factor [-]
CO2 mass window CH4 conformity factor [-] for natural gas fuelled engines only
Averaged and integrated data
Average THC concentration [ppm] [Not mandatory]
Average CO concentration [ppm] [Not mandatory]
Average NOx concentration [ppm] [Not mandatory]
Average CO2 concentration [ppm] [Not mandatory]
Average CH4 concentration [ppm] for natural gas fuelled engines only [Not mandatory]
Average Exhaust gas flow [kg/h] [Not mandatory]
Average Exhaust temperature [°C] [Not mandatory]
THC emissions [g]
CO emissions [g]
NOx emissions [g]
CO2 emissions [g]
CH4 emissions [g] for natural gas fuelled engines only
Pass-Fail results
Minimum, maximum, and 90 per cent cumulative percentile for:
Work window THC conformity factor [-]
Work window CO conformity factor [-]
Work window NOx conformity factor [-]
Work window CH4 conformity factor [-] for natural gas fuelled engines only
Annex 8
CO2 mass window THC conformity factor [-]
CO2 mass window CO conformity factor [-]
CO2 mass window NOx conformity factor [-]
CO2 mass window CH4 conformity factor [-] for natural gas fuelled engines only
Work window: Minimum and maximum average window power [%]
CO2 mass window: Minimum and maximum window duration [s]
Work window: Percentage of valid windows
CO2 mass window: Percentage of valid windows
Test verifications
THC analyser zero, span and audit results, pre and post test
CO analyser zero, span and audit results, pre and post test
NOx analyser zero-span and audit results, pre and post test
CO2 analyser zero, span and audit results, pre and post test
CH4 analyser zero, span and audit results, pre and post test for natural gas fuelled engines only
Data consistency check results, according to paragraph A.1.3.2. of Appendix 1 to this annex.
Results of the linear regression described in paragraph A.1.3.2.1. of Appendix 1 to this annex including the slope of the regression line, m, coefficient of determination, r2 and the intercept, b, of the y-axis of the regression line.
Result of the consistency check of the ECU data in accordance with paragraph A.1.3.2.2. of Appendix 1 to this Annex.
Result of the consistency check of the Brake-specific fuel consumption in accordance with paragraph A.1.3.2.3. of Appendix 1 to this annex, including the calculated Brake-specific fuel consumption and the ratio of the calculated Brake-specific fuel consumption from the PEMS measurement and the declared Brake-specific fuel consumption for the WHTC test.
Result of the consistency check of the Odometer in accordance with paragraph A.1.3.2.4. of Appendix 1 to this annex.
Result of the consistency check of the ambient pressure in accordance with paragraph A.1.3.2.5. of Appendix 1 to this annex.
List of further attachments where these exist.
Annex 8 - Appendix 1 — Test procedure for vehicle emissions testing with portable
emissions measurement systems A.1.1. Introduction This appendix describes the procedure to determine gaseous emissions from on-vehicle on-road measurements using Portable Emissions Measurement Systems (hereinafter PEMS). The gaseous emissions to be measured from the exhaust of the engine include the following components: carbon monoxide, total hydrocarbons and nitrogen oxides with the addition of methane for natural gas fuelled engines. For engines fuelled with gases other than natural gas, the manufacturer, technical service or Type Approval Authority may choose to measure the total hydrocarbon (THC) emissions instead of measuring the non-methane hydrocarbon emissions. In this case, the emission limit for the total hydrocarbon emissions is the same as shown in paragraph 5.3. of this Regulation for non-methane hydrocarbon emissions. The applicable limit in the calculations of the conformity factors in A.1.4.2.3. and A.1.4.3.2. shall in that case be the non-methane emission limit. Additionally, carbon dioxide shall be measured to enable the calculation procedures described in paragraphs A.1.3. and A.1.4. A.1.2. Test Procedure A.1.2.1. General requirements The tests shall be carried out with a PEMS comprised of: A.1.2.1.1. Gas analysers to measure the concentrations of regulated gaseous pollutants in the exhaust gas; A.1.2.1.2. An exhaust mass flow meter based on the averaging Pitot or equivalent principle; A.1.2.1.3. A Global Positioning System (hereinafter "GPS"); A.1.2.1.4. Sensors to measure the ambient temperature and pressure; A.1.2.1.5. A connection with the vehicle ECU).
Annex 8 – Appendix 1
A.1.2.2. Test parameters The parameters summarized in Table 1 shall be measured and recorded:
Test parameters
Parameter Unit Source
THC concentration1 ppm Analyzer
CO concentration ppm Analyzer
NOx concentration ppm Analyzer
CO2 concentration ppm Analyzer
1, 2
CH4 concentration ppm Analyzer
Exhaust gas flow kg/h Exhaust Flow Meter
(hereinafter EFM)
Exhaust temperature °K EFM
Ambient temperature °K Sensor
Ambient pressure kPa Sensor
Engine torque Nm ECU or Sensor
Engine speed rpm ECU or Sensor
Engine fuel flow g/s ECU or Sensor
Engine coolant temperature °K ECU or Sensor
Engine intake air °K Sensor
temperature3
Vehicle ground speed km/h ECU and GPS
Vehicle latitude degree GPS
Vehicle longitude degree GPS
Notes:
Measured or corrected to a wet basis
Only for gas engines fuelled with natural gas
Use the ambient temperature sensor or an intake air temperature sensor
The recorded value shall be either (a) the net torque or (b) the net torque calculated
from the actual engine per cent torque, the friction torque and the reference torque,
according to the SAE J1939-71 standard.
A.1.2.3. Preparation of the vehicle
The preparation of the vehicle shall include the following:
(a) The check of the OBD system: any identified problems once solved
shall be recorded and presented to the Type Approval Authority;
(b) The replacement of oil, fuel and reagent, if any.
A.1.2.4. Installation of the measuring equipment
A.1.2.4.1. Main unit
Whenever possible, PEMS shall be installed in a location where it will be
subject to minimal impact from the following:
(a) Ambient temperature changes;
(b) Ambient pressure changes;
(c) Electromagnetic radiation;
(d) Mechanical shock and vibration;
(e) Ambient hydrocarbons – if using a FID analyser that uses ambient air
as FID burner air.
The installation shall follow the instructions issued by the PEMS
manufacturer.
A.1.2.4.2. Exhaust flow meter
The exhaust flow meter shall be attached to the vehicle’s tailpipe. The EFM
sensors shall be placed between two pieces of straight tube whose length
should be at least 2 times the EFM diameter (upstream and downstream). It is
recommended to place the EFM after the vehicle silencer, to limit the effect
of exhaust gas pulsations upon the measurement signals.
A.1.2.4.3. Global Positioning System
The antenna shall be mounted at the highest possible location, without risking
interference with any obstructions encountered during on-road operation.
A.1.2.4.4. Connection with the vehicle ECU
A data logger shall be used to record the engine parameters listed in Table 1.
This data logger can make use of the Control Area Network (hereinafter
CAN) bus of the vehicle to access the ECU data broadcasted on the CAN
according to standard protocols such as SAE J1939, J1708 or ISO 15765-4.
A.1.2.4.5. Sampling of gaseous emissions
The sample line shall be heated according to the specifications of
paragraph A.2.2.3. of Appendix 2 to this annex and properly insulated at the
connection points (sample probe and back of the main unit), to avoid the
presence of cold spots that could lead to a contamination of the sampling
system by condensed hydrocarbons.
The sample probe shall be installed in the exhaust pipe in accordance with the
requirements of paragraph 9.3.10. of Annex 4.
If the length of the sample line is changed, the system transport times shall be
verified and if necessary corrected.
A.1.2.5. Pre-test procedures
A.1.2.5.1. Starting and stabilizing the PEMS instruments
The main units shall be warmed up and stabilized, according to the
instrument manufacturer specifications, until pressures, temperatures and
flows have reached their operating set points.
A.1.2.5.2. Cleaning the sampling system
To prevent system contamination, the sampling lines of the PEMS
instruments shall be purged until sampling begins, according to the
instrument manufacturer specifications.
Annex 8 – Appendix 1
A.1.2.5.3. Checking and calibrating the analysers
The zero and span calibration and the linearity checks of the analysers shall
be performed using calibration gases meeting the requirements of
paragraph 9.3.3. of Annex 4.
A.1.2.5.4. Cleaning the EFM
The EFM shall be purged at the pressure transducer connections in
accordance with the instrument manufacturer specifications. This procedure
shall remove condensation and diesel particulate matter from the pressure
lines and the associated flow tube pressure measurement ports.
A.1.2.6. Emissions test run
A.1.2.6.1. Test start
Emissions sampling, measurement of the exhaust parameters and recording
of the engine and ambient data shall start prior to starting the engine. The
data evaluation shall start after the coolant temperature has reached 343 K
(70 °C) for the first time or after the coolant temperature is stabilized
within +/-2 K over a period of 5 minutes whichever comes first but no later
than 20 minutes after engine start.
A.1.2.6.2. Test run
Emission sampling, measurement of the exhaust parameters and recording of
the engine and ambient data shall continue throughout the normal in-use
operation of the engine. The engine may be stopped and started, but
emissions sampling shall continue throughout the entire test.
Periodic checks of the PEMS gas analysers shall be conducted at least every
two hours. The data recorded during the checks shall be flagged and shall not
be used for the emission calculations.
A.1.2.6.3. End of test sequence
At the end of the test, sufficient time shall be given to the sampling systems
to allow their response times to elapse. The engine may be shut down before
or after sampling is stopped.
A.1.2.7. Verification of the measurements
A.1.2.7.1. Checking of the analysers
The zero, span and linearity checks of the analysers as described in
paragraph A.1.2.5.3. shall be performed using calibration gases meeting the
requirements of paragraph 9.3.3. of Annex 4.
A.1.2.7.2. Zero drift
Zero response is defined as the mean response, including noise, to a zero gas
during a time interval of at least 30 seconds. The drift of the zero response
shall be less than 2 per cent of full scale on the lowest range used.
A.1.2.7.3. Span drift
Span response is defined as the mean response, including noise, to a span gas
during a time interval of at least 30 seconds. The drift of the span response
shall be less than 2 per cent of full scale on the lowest range used.
A.1.2.7.4. Drift verification
This shall apply only if, during the test, no zero drift correction was made.
As soon as practical but no later than 30 minutes after the test is complete the
gaseous analyser ranges used shall be zeroed and spanned to check their drift
compared to the pre-test results.
The following provisions shall apply for analyser drift:
(a) If the difference between the pre-test and post-test results is less than
2 per cent as specified in paragraphs A.1.2.7.2. and A.1.2.7.3., the
measured concentrations may be used uncorrected or may be corrected
for drift according to paragraph A.1.2.7.5.;
(b) If the difference between the pre-test and post-test results is equal to
or greater than 2 per cent as specified in paragraphs A.1.2.7.2. and
A.1.2.7.3., the test shall be voided or the measured concentrations
shall be corrected for drift according to paragraph A.1.2.7.5.
A.1.2.7.5. Drift correction
If drift correction is applied in accordance with paragraph A.1.2.7.4., the
corrected concentration value shall be calculated according to
paragraph 8.6.1. of Annex 4.
The difference between the uncorrected and the corrected brake-specific
emission values shall be within ±6 per cent of the uncorrected brake-specific
emission values. If the drift is greater than 6 per cent, the test shall be voided.
If drift correction is applied, only the drift-corrected emission results shall be
used when reporting emissions.
A.1.3. Calculation of the emissions
The final test result shall be rounded in one step to the number of places to
the right of the decimal point indicated by the applicable emission standard
plus one additional significant figure, in accordance with ASTM E 29-06b.
No rounding of intermediate values leading to the final brake-specific
emission result shall be allowed.
A.1.3.1. Time alignment of data
To minimize the biasing effect of the time lag between the different signals
on the calculation of mass emissions, the data relevant for emissions
calculation shall be time aligned, as described in paragraphs A.1.3.1.1. to
A.1.3.1.4.
A.1.3.1.1. Gas analysers data
The data from the gas analysers shall be properly aligned using the procedure
in paragraph 9.3.5. of Annex 4.
A.1.3.1.2. Gas analysers and EFM data
The data from the gas analysers shall be properly aligned with the data of the
EFM using the procedure in paragraph A.1.3.1.4.
A.1.3.1.3. PEMS and engine data
The data from the PEMS (gas analysers and EFM) shall be properly aligned
with the data from the engine ECU using the procedure in
paragraph A.1.3.1.4.
Annex 8 – Appendix 1
A.1.3.1.4. Procedure for improved time-alignment of the PEMS data
The test data listed in Table 1 are split into 3 different categories:Gas analysers (THC, when applicable CH4, CO, CO2, NOx concentrations);
Exhaust Flow Meter (Exhaust mass flow and exhaust temperature);
Engine (Torque, speed, temperatures, fuel rate, vehicle speed from ECU). The time alignment of each category with the other categories shall be verified by finding the highest correlation coefficient between two series of parameters. All the parameters in a category shall be shifted to maximize the correlation factor. The following parameters shall be used to calculate the correlation coefficients: To time-align:
(a) Categories 1 and 2 (Analyzers and EFM data) with category 3 (Engine data): the vehicle speed from the GPS and from the ECU;
(b) Category 1 with category 2: the CO2 concentration and the exhaust mass;
(c) Category 2 with category 3: the CO2 concentration and the engine fuel flow. A.1.3.2. Data consistency checks A.1.3.2.1. Analysers and EFM data The consistency of the data (exhaust mass flow measured by the EFM and gas concentrations) shall be verified using a correlation between the measured fuel flow from the ECU and the fuel flow calculated using the formula in paragraph 8.4.1.6. of Annex 4. A linear regression shall be performed for the measured and calculated fuel rate values. The method of least squares shall be used, with the best fit equation having the form: y = mx + b Where: y is the calculated fuel flow [g/s] m is the slope of the regression line x is the measured fuel flow [g/s] b is the y intercept of the regression line The slope (m) and the coefficient of determination (r²) shall be calculated for each regression line. It is recommended to perform this analysis in the range from 15 per cent of the maximum value to the maximum value and at a frequency greater or equal to 1 Hz. For a test to be considered valid, the following two criteria shall be evaluated:
Tolerances
Slope of the regression line, m 0.9 to 1.1 - Recommended
Coefficient of determination r min. 0.90 - Mandatory
A.1.3.2.2. ECU torque data
The consistency of the ECU torque data shall be verified by comparing the
maximum ECU torque values at different engine speeds with the
corresponding values on the official engine full load torque curve according
to paragraph 5. of this annex.
A.1.3.2.3. Brake-Specific Fuel Consumption
The Brake Specific Fuel Consumption (BSFC) shall be checked using:
(a) The fuel consumption calculated from the emissions data (gas
analyser concentrations and exhaust mass flow data), according to the
formulae in paragraph 8.4.1.6. of Annex 4;
(b) The work calculated using the data from the ECU (Engine torque and
engine speed).
A.1.3.2.4. Odometer
The distance indicated by the vehicle odometer shall be checked against the
GPS data and verified.
A.1.3.2.5. Ambient pressure
The ambient pressure value shall be checked against the altitude indicated by
the GPS data.
A.1.3.3. Dry-Wet correction
If the concentration is measured on a dry basis, it shall be converted to a wet
basis according to the formula in paragraph 8.1. of Annex 4.
A.1.3.4. NOx correction for humidity and temperature
The NOx concentrations measured by the PEMS shall not be corrected for
ambient air temperature and humidity.
A.1.3.5. Calculation of the instantaneous gaseous emissions
The mass emissions shall be determined as described in paragraph 8.4.2.3. of
Annex 4.
A.1.4. Determination of emissions and conformity factors
A.1.4.1. Averaging window principle
The emissions shall be integrated using a moving averaging window method,
based on the reference CO2 mass or the reference work. The principle of the
calculation is as follows: the mass emissions are not calculated for the
complete data set, but for sub-sets of the complete data set, the length of
these sub-sets being determined so as to match the engine CO2 mass or work
measured over the reference laboratory transient cycle. The moving average
calculations are conducted with a time increment t equal to the data
sampling period. These sub-sets used to average the emissions data are
referred to as "averaging windows" in the following paragraphs.
Any portion of invalidated data shall not be considered for the calculation of
the work or CO2 mass and the emissions of the averaging window.
Annex 8 – Appendix 1
The following data shall be considered as invalidated data:
(a) The periodic verification of the instruments and/or after the zero drift
verifications;
(b) The data outside the conditions specified in paragraphs 4.2. and 4.3. of
this annex.
The mass emissions (mg/window) shall be determined as described in
paragraph 8.4.2.3. of Annex 4.Annex 8 - Appendix 2 — Portable measurement equipment
A.2.1. General The gaseous emissions shall be measured according to the procedure set out in Appendix 1 to this annex. The present appendix describes the characteristics of the portable measurement equipment that shall be used to perform such tests. A.2.2. Measuring equipment A.2.2.1. Gas analysers general specifications The PEMS gas analysers specifications shall meet the requirements set out in paragraph 9.3.1. of Annex 4. A.2.2.2. Gas analysers technology The gases shall be analysed using the technologies specified in paragraph 9.3.2.of Annex 4. The oxides of nitrogen analyser may also be of the Non-Dispersive Ultra Violet (NDUV) type. A.2.2.3. Sampling of gaseous emissions The sampling probes shall meet the requirements defined in paragraph A.2.1.2. of Appendix 2 to Annex 4. The sampling line shall be heated to 190 °C (+/-10°C). A.2.2.4. Other instruments The measuring instruments shall satisfy the requirements given in Table 7 in Annex 4 and paragraph 9.3.1. to Annex 4. A.2.3. Auxiliary equipment A.2.3.1. Exhaust Gas Flow Meter (EFM) tailpipe connection The installation of the EFM shall not increase the backpressure by more than the value recommended by the engine manufacturer, nor increase the length of the tailpipe by more than 1.2 m. As for the all the components of the PEMS equipment, the installation of the EFM shall comply with the locally applicable road safety regulations and insurance requirements. A.2.3.2. PEMS location and mounting hardware The PEMS equipment shall be installed as specified in paragraph A.1.2.4. of Appendix 1 to this annex. A.2.3.3. Electrical power The PEMS equipment shall be powered using the method described in paragraph 4.6.6. of this annex.
Annex 8 - Appendix 3 — Calibration of portable measurement equipment
A.3.1. Equipment calibration and verification A.3.1.1. Calibration gases The PEMS gas analysers shall be calibrated using gases meeting the requirements as set out in paragraph 9.3.3. of Annex 4. A.3.1.2. Leakage test The PEMS leakage tests shall be conducted following the requirements defined in paragraph 9.3.4. of Annex 4. A.3.1.3. Response time check of the analytical system The response time check of the PEMS analytical system shall be conducted in accordance with the requirements set out in paragraph 9.3.5. of Annex 4.
Annex 8 – Appendix 4
Annex 8 - Appendix 4 — Method to check the conformity of the ECU torque-signal
A.4.1. Introduction This appendix describes in a non-detailed manner the method used to check the conformity of the ECU torque-signal during ISC-PEMS testing. The detailed applicable procedure is left to the engine manufacturer, subject to approval of the Type Approval Authority. A.4.2. The "Maximum torque" method A.4.2.1. The "Maximum torque" method consists of demonstrating that a point on the reference maximum torque curve as a function of the engine speed has been reached during vehicle testing. A.4.2.2. If a point on the reference maximum torque curve as a function of the engine speed has not been reached during the ISC PEMS emissions testing, the manufacturer is entitled to modify the load of the vehicle and/or the testing route as necessary in order to perform that demonstration after the ISC PEMS emissions test has been completed.
Annex 9A
Annex 9A
On-board diagnostic systems (OBD)
1.Introduction
This annex sets out the functional aspects of on-board diagnostic (OBD) systems for the control of emissions from engine systems which are covered by this Regulation.
2.General requirements
The general requirements, including the specific requirements for electronic system security, shall be those set out in paragraph 4. of Annex 9B and those described in paragraph 2. of this annex.
Reserved
Additional provisions concerning monitoring requirements.
Malfunctioning injectors
The manufacturer shall submit to the Type Approval Authority an analysis of the long-term effects on the emission control system of malfunctioning fuel injectors (for example clogged or soiled injectors) even if the OBD Threshold Limits (OTLs) are not exceeded as a consequence of these malfunctions.
After the period set out in paragraph 4.10.7. of this Regulation the manufacturer shall submit to the Type Approval Authority a plan of the monitoring techniques he intends to use in addition to those required by Appendix 3 to Annex 9B in order to diagnose the effects considered in paragraph 2.3.1.1.
After approval of this plan by the authority, the manufacturer shall implement those techniques in the OBD system in order to get a type approval.
Monitoring requirements concerning particulate after treatment devices
The performance of the particulate after treatment device including the filtration and continuous regeneration processes shall be monitored against the OBD threshold limit specified in Table 1.
In the case of a wall flow diesel particulate filter (DPF), the manufacturer may choose to apply the performance monitoring requirements set out in Appendix 8 to Annex 9B instead of the requirements of paragraph 2.3.2.1., if he can demonstrate with technical documentation that in case of deterioration there is a positive correlation between the loss of filtration efficiency and the loss of pressure drop ("delta pressure") across the DPF under the operating conditions of the engine specified in the test described in Appendix 8 to Annex 9B.
Annex 9A
Alternative approval
Reserved1
As an alternative to the requirements set out in paragraph 4. of Annex 9B and those described in this annex, engine manufacturers whose world-wide annual production of engines within an engine type subject to this Regulation is less than 500 engines per year, may obtain type approval on the basis of the requirements of this Regulation when the emission control components of the engine-system are at least monitored for circuit continuity, and for rationality and plausibility of sensor outputs, and when the after-treatment system is at least monitored for total functional failure. Engine manufacturers whose world-wide annual production of engines within an engine type subject to this Regulation is less than 50 engines per year, may obtain type approval on the basis of the requirements of this Regulation when the emission control components of the engine system are at least monitored for circuit continuity, and for rationality and plausibility of sensor outputs ("component monitoring"). A manufacturer shall not be permitted to use the alternative provisions specified in this paragraph for more than 500 engines per year.
The Type Approval Authority shall inform the other Contracting Parties of the circumstances of each type approval granted under [paragraph 2.4.1. and] paragraph 2.4.2.
Conformity of production
The OBD system is subject to the requirements for conformity of production specified in paragraph 8.4. of this Regulation. If the Type Approval Authority decides that verification of the conformity of production of the OBD system is required, the verification shall be conducted in accordance with the requirements specified in paragraph 8.4. of this Regulation.
3.Performance requirements
The performance requirements shall be those set out in paragraph 5. of Annex 9B.
OBD threshold limits
The OBD threshold limits (hereinafter OTLs) applicable to the OBD system are those specified in the rows "general requirements" of Table 1 for compression ignition engines and of Table 2 for gas-fuelled engines and positive ignition engines fitted to vehicles belonging to category M 3, to N2 vehicles having a maximum permissible mass exceeding 7.5 tonnes, and to N3 vehicles.
This paragraph has been reserved for future alternative approvals (e.g. transposition of Euro VI into Regulation No. 83).
Annex 9A
Until the end of the phase-in period set out in paragraph 4.10.7. of this Regulation, the OBD threshold limits specified in rows "phase-in period" of
for compression ignition engines and of Table 2 for gas fuelled
engines and positive ignition engines fitted to vehicles belonging to category
M3, to N2 vehicles having a maximum permissible mass exceeding 7.5 tonnes
and, to N3 vehicles shall apply.
OTLs (Compression ignition engines)
Limit in mg/kWh
NOx PM Mass
Phase-in period 1,500 25
General requirements 1,200 25OTLs (all gas fuelled engines and positive ignition engines fitted to vehicles belonging
to category M3, to N2 vehicles having a maximum permissible mass exceeding
7.5 tonnes, and to N3 vehicles)
Limit in mg/kWh
NOx CO1
Phase-in period 1,500
General requirements 1,200
The OTL for CO shall be set at a later stage.4.Demonstration requirements
The demonstration requirements and test procedures shall be those set out in paragraphs 6. and 7. of Annex 9B.
5.Documentation requirements
The documentation requirements shall be those set out in paragraph 8. of Annex 9B.
6.In-use performance requirements
The requirements of this paragraph shall apply to the OBD system monitors in accordance with the provisions of Annex 9C.
Technical requirements
The technical requirements for assessing the in-use performance of OBD systems including requirements concerning communication protocols, numerators, denominators and their increment shall be those set out in Annex 9C.
In particular, the in-use performance ratio (IUPRm) of a specific monitor m of the OBD system shall be calculated by the following formula: IUPRm = Numeratorm / Denominatorm
Annex 9A
Where: "Numeratorm" means the numerator of a specific monitor m and is a counter indicating the number of times a vehicle has been operated in such a way that all monitoring conditions necessary for that specific monitor to detect a malfunction have been encountered; and "Denominatorm" means the denominator of a specific monitor m and is a counter indicating the number of vehicle driving cycles that are of relevance to that specific monitor (or, "in which events occur that are of relevance to that specific monitor. ").
The in-use performance ratio (IUPRg) of a group g of monitors on board a vehicle is calculated by the following formula: IUPRg = Numeratorg / Denominatorg Where: "Numeratorg" means the numerator of a group g of monitors and is the actual value (Numeratorm) of the specific monitor m that has the lowest in-use performance ratio as defined in paragraph 6.1.2. of all monitors within that group g of monitors on board a particular vehicle; and "Denominatorg" means the denominator of a group g of monitors and is the actual value (Denominatorm) of the specific monitor m that has the lowest in- use performance ratio as defined in paragraph 6.1.2. of all monitors within that group g of monitors on board a particular vehicle.
Minimum in-use performance ratio
The in-use performance ratio IUPRm of a monitor m of the OBD system as defined in paragraph 5. of Annex 9C, shall be greater than or equal to the minimum in-use-performance ratio IUPRm(min) applicable to the monitor m throughout the useful life of the engine as specified in paragraph 5.4. of this Regulation.
The value of minimum in-use-performance ratio IUPR(min) is 0.1 for all monitors.
The requirement of paragraph 6.2.1. is deemed to be fulfilled if for all groups of monitors g the following conditions are met:
The average value IUPRg of the values IUPRg of all vehicles equipped with engines belonging to the OBD engine family under consideration is equal to or above IUPR(min), and
More than 50 per cent of all engines considered in paragraph 6.2.3.1. have an IUPRg equal to or above IUPR(min).
Documentation requirements
The documentation associated with each monitored component or system and required by paragraph 8. of Annex 9B shall include the following information concerning in-use performance data:
Annex 9A
a) The criteria used for incrementing the numerator and the denominator;
b) Any criterion for disabling incrementation of the numerator or of the denominator.
Any criterion for disabling incrementation of the general denominator shall be added to the documentation referred to in paragraph 6.3.1.
Statement of OBD in-use Performance compliance
In the application for type approval, the manufacturer shall provide a statement of OBD in-use Performance compliance in accordance with the model set out in Appendix 2 to this annex. In addition to this statement, compliance with the requirements of paragraph 6.1. shall be verified through the additional assessment rules specified in paragraph 6.5.
This statement referred to in paragraph 6.4.1. shall be attached to the documentation related to the OBD engine-family required by paragraphs 5. and 6.3. of this annex.
The manufacturer shall maintain records which contain all test data, engineering and manufacturing analyses, and other information which provides the basis for the OBD in-use performance compliance statement. The manufacturer shall make such information available to the Type Approval Authority upon request.
During the phase-in period set out in paragraph 4.10.7. of this Regulation, the manufacturer shall be exempted from providing the statement required by paragraph 6.4.1.
Assessment of the in-use performance
The OBD in-use performance and compliance with paragraph 6.2.3. of this annex shall be demonstrated at least according to the procedure set out in Appendix 1 to this annex.
National authorities and their delegates may pursue further tests to verify compliance with paragraph 6.2.3. of this annex.
To demonstrate non-compliance with the requirements of paragraph 6.2.3. of this annex, based on the provision of paragraph 6.5.2. of this annex, the authorities must show for at least one of the requirements of paragraph 6.2.3. of this annex non-compliance with a statistical confidence level of 95 per cent, based on a sample of at least 30 vehicles.
The manufacturer shall have the opportunity to establish compliance with the requirements of paragraph 6.2.3. of this annex, for which non-compliance was demonstrated according to paragraph 6.5.2.1. of this annex, by using a test based on a sample of at least 30 vehicles, with a better statistical confidence than the test mentioned in paragraph 6.5.2.1.
For tests performed according to paragraphs 6.5.2.1. and 6.5.2.2. both authorities and manufacturers must disclose relevant details, such as those relating to the selection of the vehicles, to the other party.
If non-compliance with the requirements of paragraph 6.2.3. of this annex is established according to paragraphs 6.5.1. or 6.5.2. of this annex, remedial measures in accordance with paragraph 9.3. of this Regulation shall be taken.
Annex 9A – Appendix 1
Annex 9A - Appendix 1
Assessment of the in-use performance of the on-board diagnostic system A.1.1. General A.1.1.1. This appendix sets out the procedure to be followed when demonstrating the OBD in-use performance with regard to the provisions set out in paragraph 6. of this annex. A.1.2. Procedure for demonstrating OBD in-use performance A.1.2.1. The OBD in-use performance of an engine family shall be demonstrated by the manufacturer to the Type Approval Authority that granted the type approval for the vehicles or engines concerned. The demonstration shall require consideration of the OBD in-use performance of all OBD engine families within the engine family under consideration (Figure 1).
of Annex 9A. (Name of manufacturer) makes this statement in good faith, after having performed an appropriate engineering evaluation of the OBD in-use performance of the engines within the OBD engine family over the applicable range of operating and ambient conditions." [date]
Annex 9B
Annex 9B
Technical requirements for on-board diagnostic systems (OBD)
1.Introduction
This annex sets out the technical requirements of on-board diagnostic (OBD) systems for the control of emissions from engine systems which are covered by this Regulation. This annex is based on the world-wide harmonized OBD global technical regulation (gtr) No. 5.
2.Reserved1
3.Definitions
"Alert system" means a system on-board the vehicle which informs the driver of the vehicle or any other interested party that the OBD system has detected a malfunction.
"Calibration verification number" means the number that is calculated and reported by the engine system to validate the calibration/software integrity.
"Component monitoring" means the monitoring of input components for electrical circuit failures and rationality failures and monitoring of output components for electrical circuit failures and functionality failures. It refers to components that are electrically connected to the controller(s) of the engine system.
"Confirmed and active DTC" means a DTC that is stored during the time the OBD system concludes that a malfunction exists.
"Continuous-MI" means the malfunction indicator showing a steady indication at all times while the key is in the on (run) position with the engine running (ignition on - engine on).
"Deficiency" means an OBD monitoring strategy or other OBD feature that does not meet all the detailed requirements of this annex.
"Electrical circuit failure" means a malfunction (e.g. open circuit or short circuit) that leads to the measured signal (i.e. voltages, currents, frequencies, etc.) being outside the range where the transfer functions of the sensor is designed to operate.
"Emission OBD family" means a manufacturer's grouping of engine systems having common methods of monitoring/diagnosing emission-related malfunctions.
The numbering of this annex is consistent with the numbering of gtr No. 5 on WWH-OBD. However, some paragraphs of the WWH-OBD gtr are not needed in this annex.
Annex 9B
"Emission threshold monitoring" means monitoring of a malfunction that leads to an excess of the OBD threshold limits (OTLs) and which consists of either or both of the following:
(a) Direct emissions measurement via a tailpipe emissions sensor(s) and a model to correlate the direct emissions to specific emissions of the applicable test-cycle;
(b) Indication of an emissions increase via correlation of computer input and output information to test-cycle specific emissions.
"Functionality failure" means a malfunction where an output component does not respond to a computer command in the expected way.
"Malfunction emission control strategy (MECS)" means a strategy within the engine system that is activated as a result of an emission-related malfunction.
"MI status" means the command status of the MI, being either continuous-
MI, Short-MI, on-demand-MI, or off.
"Monitoring" (see "emission threshold monitoring", "performance monitoring", and "total functional failure monitoring")
"OBD test-cycle" means the cycle over which an engine system is operated on an engine test-bed to evaluate the response of an OBD system to the presence of a qualified deteriorated component.
"OBD-parent engine system" means an engine system that has been selected from an emission-OBD family for which most of its OBD elements of design are representative of that family.
"On-demand-MI" means the malfunction indicator showing a steady indication in response to a manual demand from the driving position when the key is in the on (run) position with the engine off (ignition on - engine off).
"Pending DTC" means a DTC that is stored by the OBD system because a monitor has detected a situation where a malfunction may be present during the current or last completed operating sequence.
"Potential DTC" means a DTC that is stored by the OBD system because a monitor has detected a situation where a malfunction may be present but requires further evaluation to be confirmed. A potential DTC is a pending DTC which is not a confirmed and active DTC.
"Previously active DTC" means a formerly confirmed and active DTC that remains stored after the OBD system has concluded that the malfunction that caused the DTC is no longer present.
"Rationality failure" means a malfunction where the signal from an individual sensor or component is at variance with that expected when assessed against signals available from other sensors or components within the control system. Rationality failures include malfunctions that lead to the measured signals (i.e. voltages, currents, frequencies, etc.) being inside the range where the transfer functions of the sensor is designed to operate.
"Readiness" means a status indicating whether a monitor or a group of monitors have run since the last erasing by an external request or command (for example through an OBD scan-tool).
Annex 9B
"Short-MI" means the malfunction indicator showing a steady indication from the time the key is moved to on (run) position and the engine is started (ignition on - engine on) and extinguishing after 15 seconds or the key is moved to off, whichever occurs first.
"Software calibration identification" means a series of alphanumeric characters that identifies the emission-related calibration / software version(s) installed in the engine system.
"Total functional failure monitoring" means monitoring a malfunction which is leading to a complete loss of the desired function of a system.
"Warm-up cycle" means sufficient engine operation such that the coolant temperature has risen by at least 22 K (22 °C / 40 °F) from engine starting and reaches a minimum temperature of 333 K (60 °C / 140 °F)2.
Abbreviations
AES Auxiliary Emission Strategy CV Crankcase Ventilation DOC Diesel Oxidation Catalyst DPF Diesel Particulate Filter or Particulate Trap including catalyzed DPFs and Continuously Regenerating Traps (CRT) DTC Diagnostic trouble code EGR Exhaust Gas Recirculation HC Hydrocarbon LNT Lean NOx Trap (or NOx absorber) LPG Liquefied Petroleum Gas MECS Malfunction Emission Control Strategy NG Natural Gas NOx Oxides of Nitrogen OTL OBD Threshold Limit PM Particulate Matter SCR Selective Catalytic Reduction SW Screen Wipers TFF Total Functional Failure monitoring VGT Variable Geometry Turbocharger VVT Variable Valve Timing
This definition does not imply that a temperature sensor is necessary to measure the coolant temperature.
Annex 9B
4.General requirements
In the context of this annex, the OBD system shall have the capability of detecting malfunctions, of indicating their occurrence by means of a malfunction indicator, of identifying the likely area of the malfunctions by means of information stored in computer memory, and communicating that information off-board. The OBD system shall be designed and constructed so as to enable it to identify types of malfunctions over the complete life of the vehicle/engine. In achieving this objective, the Type Approval Authority will recognize that engines which have been used in excess of their regulatory useful life may show some deterioration in OBD system performance and sensitivity such that the OBD thresholds may be exceeded before the OBD system signals a malfunction to the driver of the vehicle. The above paragraph does not extend the engine manufacturer's compliance liability for an engine beyond its regulated useful life (i.e. the time or distance period during which emission standards or emission limits continue to apply).
Application for approval of an OBD system
Primary approval
The manufacturer of an engine system may apply for the approval of its OBD system in one of the three following manners:
(a) The manufacturer of an engine system applies for the approval of an individual OBD system by demonstrating that OBD system complies with all the provisions of this annex;
(b) The manufacturer of an engine system applies for the approval of an emission-OBD family by demonstrating that the OBD-parent engine system of the family complies with all the provisions of this annex. The manufacturer of an engine system applies for the approval of an OBD system by demonstrating that OBD system meets the criteria for belonging to an emission-OBD family that has already been certified.
Extension / Modification of an existing certificate
Extension to include a new engine system into an emission-OBD family
At the request of the manufacturer and upon approval of the Type Approval Authority, a new engine system may be included as a member of a certified emission-OBD family if all the engine systems within the so-extended emission-OBD family still have common methods of monitoring / diagnosing emission-related malfunctions. If all OBD elements of design of the OBD-parent engine system are representative of those of the new engine system, then the OBD-parent engine system shall remain unchanged and the manufacturer shall modify the documentation package according to paragraph 8. of this annex. If the new engine system contains elements of design that are not represented by the OBD-parent engine system but itself would represent the whole family, then the new engine system shall become the new OBD-parent engine
Annex 9B
system. In this case the new OBD elements of design shall be demonstrated to comply with the provisions of this annex, and the documentation package shall be modified according to paragraph 8. of this annex.
Extension to address a design change that affects the OBD system
At the request of the manufacturer and upon approval of the Type Approval Authority, an extension of an existing certificate may be granted in the case of a design change of the OBD system if the manufacturer demonstrates that the design changes comply with the provisions of this annex. The documentation package shall be modified according to paragraph 8. of this annex. If the existing certificate applies to an emission-OBD family, the manufacturer shall justify to the Type Approval Authority that the methods of monitoring/diagnosing emission-related malfunctions are still common within the family and that the OBD-parent engine system remains representative of the family.
Certificate modification to address a malfunction reclassification
This paragraph applies when, following a request by the authority that granted the approval, or at its own initiative, the manufacturer applies for a modification of an existing certificate in order to reclassify one or several malfunctions. The compliance of the new classification shall then be demonstrated according to the provisions of this annex and the documentation package shall be modified according to paragraph 8. of this annex.
Monitoring requirements
All emission-related components and systems included in an engine system shall be monitored by the OBD system in accordance with the requirements set in Appendix 3 to this annex. However, the OBD system is not required to use a unique monitor to detect each malfunction referred to in Appendix 3 to this annex. The OBD system shall also monitor its own components. The items of Appendix 3 to this annex list the systems or components required to be monitored by the OBD system and describes the types of monitoring expected for each of these components or systems (i.e. emission threshold monitoring, performance monitoring, total functional failure monitoring, or component monitoring). The manufacturer can decide to monitor additional systems and components.
Selection of the monitoring technique
Approval authorities may approve a manufacturer's use of another type of monitoring technique than the one mentioned in Appendix 3 to this annex. The chosen type of monitoring shall be shown by the manufacturer, to be robust, timely and efficient (i.e. through technical considerations, test results, previous agreements, etc.).
Annex 9B
In case a system and/or component is not covered by Appendix 3 to this annex the manufacturer shall submit for approval to the Type Approval Authority an approach to monitoring. The Type Approval Authority will approve the chosen type of monitoring and monitoring technique (i.e. emission threshold monitoring, performance monitoring, total functional failure monitoring, or component monitoring) if it has been shown by the manufacturer, by reference to those detailed in Appendix 3 to this annex, to be robust, timely and efficient (i.e. through either technical considerations, test results, previous agreements, etc.).
Correlation to actual emissions
In the case of emission threshold monitoring, a correlation to test-cycle specific emissions shall be required. This correlation would typically be demonstrated on a test engine in a laboratory setting. In all other monitoring cases (i.e. performance monitoring, total functional failure monitoring, or component monitoring), no correlation to actual emissions is necessary. However, the Type Approval Authority may request test data to verify the classification of the malfunction effects as described in paragraph 6.2. of this annex. Examples: An electrical malfunction may not require a correlation because this is a yes/no malfunction. A DPF malfunction monitored via delta pressure may not require a correlation because it anticipates a malfunction. If the manufacturer demonstrates, according to the demonstration requirements of this annex, that emissions would not exceed the OBD threshold limits upon total failure or removal of a component or system, a performance monitoring of this component or system shall be accepted. When a tailpipe emission sensor is used for monitoring the emissions of a specific pollutant all other monitors may be exempted from further correlation to the actual emissions of that pollutant. Nevertheless, such exemption shall not preclude the need to include these monitors, using other monitoring techniques, as part of the OBD system as the monitors are still needed for the purpose of malfunction isolation. A malfunction shall always be classified according to paragraph 4.5. based on its impact on emissions, regardless of the type of monitoring used to detect the malfunction.
Component monitoring (input/output components/systems)
In the case of input components that belong to the engine system, the OBD system shall at a minimum detect electrical circuit failures and, where feasible, rationality failures. The rationality failure diagnostics shall then verify that a sensor output is neither inappropriately high nor inappropriately low (i.e. there shall be "two- sided" diagnostics).
Annex 9B
To the extent feasible, and with the agreement of the Type Approval Authority, the OBD system shall detect separately, rationality failures (e.g. inappropriately high and inappropriately low), and electrical circuit failures (e.g. out-of-range high and out-of-range low). Additionally, unique DTCs for each distinct malfunction (e.g. out-of-range low, out-of-range high and rationality failure) shall be stored. In the case of output components that belong to the engine system, the OBD system shall at a minimum detect electrical circuit failures, and, where feasible, if the proper functional response to computer commands does not occur. To the extent feasible, and with the agreement of the Type Approval Authority, the OBD system shall detect separately functionality failures, electrical circuit failures (e.g. out-of-range high and out-of-range low) and store unique DTCs for each distinct malfunction (e.g. out-of-range low, out- of-range high, functionality failure). The OBD system shall also perform rationality monitoring on the information coming from or provided to components that do not belong to the engine system when this information compromises the emission control system and/or the engine system for proper performance.
Exception to component monitoring
Monitoring of electrical circuit failures, and to the extent feasible, functionality, and rationality failures of the engine system shall not be required if all the following conditions are met:
(a) The failure results in an emission increase of any pollutant of less than 50 per cent of the regulated emission limit; and
(b) The failure does not cause any emission to exceed the regulated emission limit3; and
(c) The failure does not affect a component or system enabling the proper performance of the OBD system; and
(d) The failure does not substantially delay or affect the ability of the emission control system to operate as originally designed (for example a breakdown of the reagent heating system under cold conditions cannot be considered as an exception). Determination of the emissions impact shall be performed on a stabilized engine system in an engine dynamometer test cell, according to the demonstration procedures of this annex. When such a demonstration would not be conclusive regarding criterion (d), the manufacturer shall submit to the Type Approval Authority appropriate design elements such as good engineering practice, technical considerations, simulations, test results, etc.
The measured value shall be considered taking into account the relevant precision tolerance of the test-cell system and the increased variability in the test results due to the malfunction.
Annex 9B
Monitoring frequency
Monitors shall run continuously, at any time where the monitoring conditions are fulfilled, or once per operating sequence (e.g. for monitors that lead to an increase of emission when it runs). At the request of the manufacturer, the Type Approval Authority may approve monitors that do not run continuously. In that case the manufacturer shall clearly inform the Type Approval Authority and describe the conditions under which the monitor runs and justify the proposal by appropriate design elements (such as good engineering practice). The monitors shall run during the applicable OBD test-cycle as specified in paragraph 7.2.2. A monitor shall be regarded as running continuously, if it runs at a rate not less than twice per second and concludes the presence or the absence of the failure relevant to that monitor within 15 seconds. If a computer input or output component is sampled less frequently than twice per second for engine control purpose, a monitor shall also be regarded as running continuously, if the system concludes the presence or the absence of the failure relevant to that monitor each time sampling occurs. For components or systems monitored continuously, it is not required to activate an output component/system for the sole purpose of monitoring that output component/system.
Requirements for recording OBD information
When a malfunction has been detected but is not yet confirmed, the possible malfunction shall be considered as a "Potential DTC" and accordingly a "Pending DTC" status shall be recorded. A "Potential DTC" shall not lead to an activation of the alert system according to paragraph 4.6. Within the first operating sequence, a malfunction may be directly considered "confirmed and active" without having been considered a "potential DTC". It shall be given the "Pending DTC" and a "confirmed and active DTC" status. In case a malfunction with the previously active status occurs again, that malfunction may at the choice of manufacturer be directly given the "Pending DTC" and "confirmed and active DTC" status without having been given the "potential DTC" status. If that malfunction is given the potential status, it shall also keep the previously active status during the time it is not yet confirmed and active. The monitoring system shall conclude whether a malfunction is present before the end of the next operating sequence following its first detection. At this time, a "confirmed and active" DTC shall be stored and the alert system be activated according to paragraph 4.6. In case of a recoverable MECS (i.e. the operation automatically returns to normal and the MECS is de-activated at the next engine ON), a "confirmed and active" DTC need not be stored unless the MECS is again activated before the end of the next operating sequence. In case of a non-recoverable MECS, a "confirmed and active" DTC shall be stored as soon as the MECS is activated.
Annex 9B
In some specific cases where monitors need more than two operating sequences to accurately detect and confirm a malfunction (e.g. monitors using statistical models or with respect to fluid consumption on the vehicle), the Type Approval Authority may permit the use of more than two operating sequences for monitoring provided the manufacturer justifies the need for the longer period (e.g. by technical rationale, experimental results, in house experience, etc.). When a confirmed and active malfunction is no longer detected by the system during a complete operating sequence, it shall be given the previously active status by the start of the next operating sequence and keep that status until the OBD information associated with this malfunction is erased by a scan tool or erased from the computer memory according to paragraph 4.4. Note: The requirements prescribed in this paragraph are illustrated in Appendix 2 to this annex.
Requirements for erasing OBD information
DTC and the applicable information (inclusive the associated freeze frame) shall not be erased by the OBD system itself from the computer memory until that DTC has been in the previously active status for at least 40 warm-up cycles or 200 engine operating hours, whichever occurs first. The OBD system shall erase all the DTCs and the applicable information (inclusive the associated freeze frame) upon request of a scan tool or a maintenance tool.
Requirements for malfunction classification
Malfunction classification specifies the class to which a malfunction is assigned, when such a malfunction is detected according to the requirements of paragraph 4.2. of this annex. A malfunction shall be assigned to one class for the actual life of the vehicle unless the authority that granted the certificate or the manufacturer determines that reclassification of that malfunction is necessary. If a malfunction would result in a different classification for different regulated pollutant emissions or for its impact on other monitoring capability, the malfunction shall be assigned to the class that takes precedence in the discriminatory display strategy. If an MECS is activated as a result of the detection of a malfunction, this malfunction shall be classified based on either the emission impact of the activated MECS or its impact on other monitoring capability. The malfunction shall then be assigned to the class that takes precedence in the discriminatory display strategy.
Class A malfunction
A malfunction shall be identified as Class A when the relevant OBD threshold limits (OTLs) are assumed to be exceeded. It is accepted that the emissions may not be above the OTLs when this class of malfunction occurs.
Annex 9B
Class B1 malfunction
A malfunction shall be identified as Class B1 where circumstances exist that have the potential to lead to emissions being above the OTLs but for which the exact influence on emission cannot be estimated and thus the actual emissions according to circumstances may be above or below the OTLs. Examples of Class B1 malfunctions may include malfunctions detected by monitors that infer emission levels based on readings of sensors or restricted monitoring capability. Class B1 malfunctions shall include malfunctions that restrict the ability of the OBD system to carry out monitoring of Class A or B1 malfunctions.
Class B2 malfunction
A malfunction shall be identified as Class B2 when circumstances exist that are assumed to influence emissions but not to a level that exceeds the OTL. Malfunctions that restrict the ability of the OBD system to carry out monitoring of Class B2 malfunctions of shall be classified into Class B1 or B2.
Class C malfunction
A malfunction shall be identified as Class C when circumstances exist that, if monitored, are assumed to influence emissions but to a level that would not exceed the regulated emission limits. Malfunctions that restrict the ability of the OBD system to carry out monitoring of Class C malfunctions shall be classified into Class B1 or B2.
Alert system
The failure of a component of the alert system shall not cause the OBD system to stop functioning.
MI specification
The malfunction indicator shall be a visual signal that is perceptible under all lighting conditions. The malfunction indicator shall comprise a yellow or amber (as defined in UN/ECE Regulation No. 37) warning signal identified by the 0640 symbol in accordance with ISO Standard 7000:2004.
MI illumination schemes
Depending on the malfunction(s) detected by the OBD system, the MI shall be illuminated according to one of the activation modes described in the following table:
Activation mode 1 Activation mode 2 Activation mode 3 Activation mode 4
Class B malfunction Class A malfunction Conditions of Class C No malfunction and B1 counters or B1 counter activation malfunction < 200 h > 200 h Key on engine Discriminatory Discriminatory display Discriminatory display No display on display strategy strategy strategy Key on engine Harmonized Harmonized Harmonized display Harmonized display off display strategy display strategy strategy strategy
Annex 9B
The display strategy requires the MI to be activated according to the class in which a malfunction has been classified. This strategy shall be locked by software coding that shall not be routinely available via the scan tool. The MI activation strategy at key on, engine off is described in paragraph 4.6.4. Figures B1 and B2 illustrate the prescribed activation strategies at key on, engine on or off. Figure B1 Bulb test and readiness indication
ENGINE ON ENGINE OFF
a) MI (bulb) functioning, no malfunction to report, and the readiness of all monitored components "complete". MI On Bulb Test Ready Mode 1 - No DTCs MI On Key On
Key On Separator Separator MI Off MI Off Trip Duration 5s 10 s 5s 5s 1s 5s
b) MI (bulb) functioning, no malfunction to report, and at least one component with readiness "not complete". MI On Bulb Test Not Ready Mode 1 - No DTCs MI On “Ready Status” reporting is Key On
Key On
not supported while engine is on.
Separator Separator MI Off MI Off Trip Duration 5s 10 s 5s 5s 1s 5s
c) MI (bulb) non operational Bulb Test MI On MI On Key On Key On
MI Off MI Off 5s 10 s 5s 5s Discriminatory Trip Duration status
Annex 9B
Figure B.2 Malfunction display strategy: only the discriminatory strategy is applicable
WWH Harmonized Non-Discriminatory System Discriminatory System ENGINE ON ENGINE OFF
d) Activation mode 4 Bulb Test Ready Mode 4 - Continuous MI MI On MI On
Key O n Key On
Separator Separator MI Off MI Off Trip Duration 5s 10 s 5s 5s
e) activation mode 3 MI On Bulb Test Ready Mode 3 - Short MI MI On Key O n
Key On
Separator Separator MI Off MI Off 15 seconds 5s 10 s 5s 5s 5s 5s
f) Activation mode 2 Bulb Test Ready Mode 2 - On Deman MI MI On MI On Key On Key On
Separator Separator
MI Off MI Off 5s 10 s 5s 5s 3s 5s
g) Activation mode 4 with "not ready" status. MI On Bulb Test Not Ready Mode 4 - Continuous MI MI On Key On
Key O n
Separator MI Off MI Off Trip Duration 5s 10 s 5s 5s
h) Activation mode 3 with "not ready" status. MI On Bulb Test Not Ready Mode 3 - Short MI MI On Key O n
“Ready Status” reporting is Key On
not supported while engine is on. Separator MI Off MI Off 15 seconds 5s 10 s 5s 5s 5s 5s
MI activation at "engine on" When the key is placed in the on position and the engine is started (engine on), the MI shall be commanded off unless the provisions of paragraph 4.6.3.1. have been met.
Annex 9B
MI display strategy
For the purpose of activating the MI, continuous-MI shall take precedence to short-MI and on-demand-MI. For the purpose of activating the MI, short-MI shall take precedence to on-demand-MI.
Class A malfunctions
The OBD system shall command a continuous-MI upon storage of a confirmed DTC associated with a Class A malfunction.
Class B malfunctions
The OBD system shall command a "short-MI" at the next key-on event following storage of a confirmed and active DTC associated with a Class B malfunction. Whenever a B1 counter reaches 200 hours, the OBD system shall command a continuous-MI.
Class C malfunctions
The manufacturer may make available information on Class C malfunctions through the use of an on-demand-MI that shall be available until the engine is started.
MI de-activation scheme
The "continuous-MI" shall switch to a "short-MI" if a single monitoring event occurs and the malfunction that originally activated the continuous-MI is not detected during the current operating sequence and a continuous-MI is not activated due to another malfunction. The "short-MI" shall be deactivated if the malfunction is not detected during the 3 subsequent sequential operating sequences following the operating sequence when the monitor has concluded the absence of the considered malfunction and the MI is not activated due to another Class A or B malfunction. Figures 1, 4A and 4B in Appendix 2 to this annex illustrate respectively the short and continuous MI deactivation in different use-cases.
MI activation at key-on/engine-off
The MI activation at key-on/engine-off shall consist of two sequences separated by a 5 seconds MI off:
(a) The first sequence is designed to provide an indication of the MI functionality and the readiness of the monitored components;
(b) The second sequence is designed to provide an indication of the presence of a malfunction. The second sequence is repeated until engine is started4 (engine-on) or the key is set to the key-off position. At the request of the manufacturer, this activation may only occur once during an operating sequence (for example in case of start-stop systems).
An engine may be considered started during the cranking phase.
Annex 9B
MI functionality/readiness
The MI shall show a steady indication for 5 seconds to indicate that the MI is functional. The MI shall remain at the off position for 10 seconds. The MI shall then remain at the on position for 5 seconds to indicate that the readiness for all monitored components is complete. The MI shall blink once per second for 5 seconds to indicate that the readiness for one or more of the monitored components is not complete. The MI shall then remain off for 5 seconds.
Presence / absence of a malfunction
Following the sequence described in paragraph 4.6.4.1, the MI shall indicate the presence of a malfunction by a series of flashes or a continuous illumination, depending on the applicable activation mode, as described in the following paragraphs; or the absence of a malfunction by a series of single flashes. When applicable, each flash consists of a 1s MI-on followed by a one second MI-off, and the series of flashes will be followed by a period of four seconds with the MI off. Four activation modes are considered, where activation mode 4 shall take precedence over activation modes 1, 2 and 3, activation mode 3 shall take precedence over activation modes 1 and 2, and activation mode 2 shall take precedence over activation mode 1.
Activation mode 1 - absence of malfunction
The MI shall blink for one flash.
Activation mode 2 - "On-demand-MI"
The MI shall show blink for two flashes if the OBD system would command an on-demand-MI according to the discriminatory display strategy described in paragraph 4.6.3.1.
Activation mode 3 - "short-MI"
The MI shall blink for three flashes if the OBD system would command a short-MI according to the discriminatory display strategy described in paragraph 4.6.3.1.
Activation mode 4 - "continuous-MI"
The MI shall remain continuously ON ("continuous-MI") if the OBD system would command a continuous-MI according to the discriminatory display strategy described in paragraph 4.6.3.1.
Counters associated with malfunctions
MI counters
Continuous-MI Counter
The OBD system shall contain a continuous-MI counter to record the number of hours during which the engine has been operated while a continuous-MI is activated.
Annex 9B
The continuous-MI counter shall count up to the maximum value provided in a 2 byte counter with 1 hour resolution and hold that value unless the conditions allowing the counter to be reset to zero are met. The continuous-MI counter shall operate as follows:
(a) If starting from zero, the continuous-MI counter shall begin counting as soon as a continuous-MI is activated;
(b) The continuous-MI counter shall halt and hold its present value when the continuous-MI is no longer activated;
(c) The continuous-MI counter shall continue counting from the point at which it had been held if a malfunction that results in a continuous-MI is detected within 3 operating sequences;
(d) The continuous-MI counter shall start again counting from zero when a malfunction that results in a continuous-MI is detected after 3 operating sequences since the counter was last held;
(e) The continuous-MI counter shall be reset to zero when:
(i) No malfunction that results in a continuous-MI is detected during 40 warm-up cycles or 200 engine operating hours since the counter was last held whichever occurs first; or
(ii) The OBD scan tool commands the OBD System to clear OBD information. Figure C1 Illustration of the MI counters activation principles
3 op. sequences 40 op. sequences or 200 op. hours cumulative MI counter Continuous-MI counter Continuous-MI
< 3 op. > 3 op. > 40 op. sequences sequences sequences
Annex 9B
Figure C2 Illustration of the B1 counter activation principles
3 op. sequences 200 op. hours
200 hrs
190 hrs B1 counter
MI set continuously ON
YES B1 malfunction
NO
< 3 op. < 3 op. > 3 op. sequences sequences sequences
Cumulative continuous-MI counter
The OBD system shall contain a cumulative continuous-MI counter to record the cumulative number of hours during which the engine has been operated over its life while a continuous-MI is activated. The cumulative continuous-MI counter shall count up to the maximum value provided in a 2-byte counter with 1 hour resolution and hold that value. The cumulative continuous-MI counter shall not be reset to zero by the engine system, a scan tool or a disconnection of a battery. The cumulative continuous-MI counter shall operate as follows:
(a) The cumulative continuous-MI counter shall begin counting when the continuous-MI is activated;
(b) The cumulative continuous-MI counter shall halt and hold its present value when the continuous-MI is no longer activated;
(c) The cumulative continuous-MI counter shall continue counting from the point it had been held when a continuous-MI is activated. Figure C1 illustrates the principle of the cumulative continuous-MI counter and Appendix 2 to this annex contains examples that illustrate the logic.
Annex 9B
Counters associated with Class B1 malfunctions
Single B1-counter
The OBD system shall contain a B1 counter to record the number of hours during which the engine has operated while a Class B1 malfunction is present. The B1 counter shall operate as follows:
(a) The B1 counter shall begin counting as soon as a Class B1 malfunction is detected and a confirmed and active DTC has been stored;
(b) The B1 counter shall halt and hold its present value if no Class B1 malfunction is confirmed and active, or when all Class B1 malfunction have been erased by a scan tool;
(c) The B1 counter shall continue counting from the point it had been held if a subsequent Class B1 malfunction is detected within 3 operating sequences. In the case where the B1 counter has exceeded 200 engine running hours, the OBD system shall set the counter to 190 engine running hours when the OBD system has determined that a Class B1 malfunction is no longer confirmed and active, or when all Class B1 malfunctions have been erased by a scan tool. The B1 counter shall begin counting from 190 engine running hours if a subsequent Class B1 malfunction is present within 3 operating sequences. The B1 counter shall be reset to zero when three consecutive operating sequences have occurred during which no Class B1 malfunctions have been detected. Note: The B1 counter does not indicate the number of engine running hours with a single Class B1 malfunction present. The B1 counter may accumulate the number of hours of 2 or more different Class B1 malfunctions, none of them having reached the time the counter indicates. The B1 counter is only intended to determine when the continuous-MI shall be activated. Figure C2 illustrates the principle of the B1 counter and Appendix 2 to this annex contains examples that illustrate the logic.
Multiple B1-counters
A manufacturer may use multiple B1 counters. In that case the system shall be capable of assigning a specific B1 counter to each Class B1 malfunction. The control of the specific B1 counter shall follow the same rules as the single B1 counter, where each specific B1 counter shall begin counting when the assigned Class B1 malfunction is detected.
Annex 9B
OBD information
Recorded information
The information recorded by the OBD system shall be available upon off- board request in the following packages manner:
(a) Information about the engine state;
(b) Information about active emission-related malfunctions;
(c) Information for repair.
Information about the engine state
This information will provide an enforcement agency 5 with the malfunction indicator status and associated data (e.g. continuous-MI counter, readiness). The OBD system shall provide all information (according to the applicable standard set in Appendix 6 to this annex) for the external roadside check test equipment to assimilate the data and provide an enforcement agent with the following information:
(a) Discriminatory/non-discriminatory display strategy;
(b) The VIN (vehicle identification number);
(c) Presence of a continuous-MI;
(d) The readiness of the OBD system;
(e) The number of engine operating hours during which a continuous-MI was last activated (continuous-MI counter). This information shall be read only access (i.e. no clearing).
Information about active emission-related malfunctions
This information will provide any inspection station 6 with a subset of engine related OBD data including the malfunction indicator status and associated data (MI counters), a list of active/confirmed malfunctions of classes A and B and associated data (e.g. B1-counter). The OBD system shall provide all information (according to the applicable standard set in Appendix 6 to this annex) for the external inspection test equipment to assimilate the data and provide an inspector with the following information:
(a) The gtr (and revision) number, to be integrated into Regulation No. 49 type approval marking;
(b) Discriminatory/ non-discriminatory display strategy;
(c) The VIN (vehicle identification number);
(d) The Malfunction Indicator status;
A typical use of this information package may be to establish basic emission road-worthiness of the engine system. A typical use of this information package may be to establish detailed understanding of the emission road-worthiness of the engine system.
Annex 9B
(e) The Readiness of the OBD system;
(f) Number of warm-up cycles and number of engine operating hours since recorded OBD information was last cleared;
(g) The number of engine operating hours during which a continuous-MI was last activated (continuous-MI counter);
(h) The cumulated operating hours with a continuous-MI (cumulative continuous-MI counter);
(i) The value of the B1 counter with the highest number of engine operating hours;
(j) The confirmed and active DTCs for Class A malfunctions;
(k) The confirmed and active DTCs for Classes B (B1 and B2) malfunctions;
(l) The confirmed and active DTCs for Class B1 malfunctions;
(m) The software calibration identification(s);
(n) The calibration verification number(s). This information shall be read only access (i.e. no clearing).
Information for repair
This information will provide repair technicians with all OBD data specified in this annex (e.g. freeze frame information). The OBD system shall provide all information (according to the applicable standard set in Appendix 6 to this annex) for the external repair test equipment to assimilate the data and provide a repair technician with the following information:
(a) gtr (and revision) number, to be integrated into Regulation No. 49 type approval marking;
(b) VIN (vehicle identification number);
(c) Malfunction indicator status;
(d) Readiness of the OBD system;
(e) Number of warm-up cycles and number of engine operating hours since recorded OBD information was last cleared;
(f) Monitor status (i.e. disabled for the rest of this drive cycle complete this drive cycle, or not complete this drive cycle) since last engine shut-off for each monitor used for readiness status;
(g) Number of engine operating hours since the malfunction indicator has been activated (continuous MI counter);
(h) Confirmed and active DTCs for Class A malfunctions;
(i) Confirmed and active DTCs for Classes B (B1 and B2) malfunctions;
(j) Cumulated operating hours with a continuous-MI (cumulative continuous-MI counter);
Annex 9B
(k) Value of the B1 counter with the highest number of engine operating hours;
(l) Confirmed and active DTCs for Class B1 malfunctions and the number of engine operating hours from the B1-counter(s);
(m) Confirmed and active DTCs for Class C malfunctions;
(n) Pending DTCs and their associated class;
(o) Previously active DTCs and their associated class;
(p) Real-time information on OEM selected and supported sensor signals, internal and output signals (see paragraph 4.7.2. and Appendix 5 to this annex);
(q) Freeze frame data required by this annex (see paragraph 4.7.1.4. and Appendix 5 to this annex);
(r) Software calibration identification(s);
(s) Calibration verification number(s). The OBD system shall clear all the recorded malfunctions of the engine system and related data (operating time information, freeze frame, etc.) in accordance with the provisions of this annex, when this request is provided via the external repair test equipment according to the applicable standard set in Appendix 6 to this annex.
Freeze frame information
At least one "freeze frame" of information shall be stored at the time that either a potential DTC or a confirmed and active DTC is stored at the decision of the manufacturer. The manufacturer is allowed to update the freeze frame information whenever the pending DTC is detected again. The freeze frame shall provide the operating conditions of the vehicle at the time of malfunction detection and the DTC associated with the stored data. The freeze frame shall include the information as shown in Table 1 in Appendix 5 to this annex. The freeze frame shall also include all of the information in Tables 2 and 3 of Appendix 5 to this annex that are used for monitoring or control purposes in the specific control unit that stored the DTC. Storage of freeze frame information associated with a Class A malfunction shall take precedence over information associated with a Class B1 malfunction which shall take precedence over information associated with a Class B2 malfunction and likewise for information associated with a Class C malfunction. The first malfunction detected shall take precedence over the most recent malfunction unless the most recent malfunction is of a higher class. In case a device is monitored by the OBD system and is not be covered by Appendix 5 to this annex the freeze frame information shall include elements of information for the sensors and actuators of this device in a way similar to those described in Appendix 5 to this annex. This shall be submitted for approval by the Type Approval Authority at the time of approval.
Annex 9B
Readiness
With the exceptions specified in paragraphs 4.7.1.5.1., 4.7.1.5.2. and 4.7.1.5.3., a readiness shall only be set to "complete" when a monitor or a group of monitors addressed by this status have run and concluded the presence (that means stored a confirmed and active DTC) or the absence of the failure relevant to that monitor since the last erasing by an external request or command (for example through an OBD scan-tool). Readiness shall be set to "not complete" by erasing the fault code memory (see paragraph 4.7.4.) by an external request or command (for example through an OBD scan-tool). Normal engine shutdown shall not cause the readiness to change.
The manufacturer may request, subject to approval by the Type Approval
Authority, that the ready status for a monitor be set to indicate "complete" without the monitor having run and concluded the presence or the absence of the failure relevant to that monitor, if monitoring is disabled for a multiple number of operating sequences (minimum 9 operating sequences or 72 operation hours) due to the continued presence of extreme operating conditions (e.g. cold ambient temperatures, high altitudes). Any such request must specify the conditions for monitoring system disablement and the number of operating sequences that would pass without monitor completion before ready status would be indicated as "complete". The extreme ambient or altitude conditions considered in the manufacturer's request shall never be less severe than the conditions specified by this annex for temporary disablement of the OBD system
Monitors subject to readiness
Readiness shall be supported for each of the monitors or groups of monitors that are identified in this annex and that are required when and by referring to this annex, with the exception of items 11 and 12 of Appendix 3 to this annex.
Readiness for continuous monitors
Readiness of each of the monitors or groups of monitors that are identified in items 1, 7 and 10 of Appendix 3 to this annex, required when and by referring to this annex, and that are considered by this annex as running continuously, shall always indicate "complete".
Data stream information
The OBD system shall make available to a scan tool in real time the information shown in Tables 1 to 4 in Appendix 5 to this annex, upon request (actual signal values should be used in favour of surrogate values). For the purpose of the calculated load and torque parameters, the OBD system shall report the most accurate values that are calculated within the applicable electronic control unit (e.g. the engine control computer). information relating to the engine load and speed.
in Appendix 5 to this annex shows the other OBD information which
must be included if used by the emission or OBD system to enable or disable any OBD monitors. Annex 9B
in Appendix 5 to this annex shows the information which is required
to be included if the engine is so equipped, senses or calculates the information7. At the decision of the manufacturer, other freeze frame or data stream information may be included. In case a device is monitored by the OBD system and is not covered by Appendix 5 to this annex (e.g. SCR), the data-stream information shall include elements of information for the sensors and actuators of this device in a way similar to those described in Appendix 5 to this annex. This shall be submitted for approval by the Type Approval Authority at the time of approval.
Access to OBD information
Access to OBD information shall be provided only in accordance with the standards mentioned in Appendix 6 to this annex and the following sub- paragraphs . Access to the OBD information shall not be dependent on any access code or other device or method obtainable only from the manufacturer or its suppliers. Interpretation of the OBD information shall not require any unique decoding information, unless that information is publicly available. A single access method (e.g. a single access point/node) to OBD information shall be supported to retrieve all OBD information. This method shall permit access to the complete OBD information required by this annex. This method shall also permit access to specific smaller information packages as defined in this annex (e.g. road worthiness information packages in case of emission related OBD). Access to OBD information shall be provided using at least one of the following series of standards mentioned in Appendix 6 to this annex:
(a) ISO 27145 with ISO 15765-4 (CAN-based);
(b) ISO 27145 with ISO 13400 (TCP/IP-based);
(c) SAE J1939-73. Manufacturers shall use appropriate ISO or SAE-defined fault codes (for example, P0xxx, P2xxx, etc.) whenever possible. If such identification is not possible, the manufacturer may use diagnostic trouble codes according to the relevant clauses in ISO 27145 or SAE J1939. The fault codes must be fully accessible by standardized diagnostic equipment complying with the provisions of this annex. The manufacturer shall provide the ISO or SAE standardization body through the appropriate ISO or SAE process with emission-related diagnostic data not specified by ISO 27145 or SAE J1939 but related to this annex.
It is not required to equip the engine for the sole purpose of providing the information data mentioned in Tables 3 and 4 of Annex 5. The manufacturer is allowed to use an additional on-board diagnostic display, such as a dashboard mounted video display device, for providing access to OBD information. Such an additional device is not subject to the requirements of this annex.
Annex 9B
Access to OBD information shall be possible by the means of a wired connection. OBD data shall be provided by the OBD system upon request using scan tool that complies with the requirements of the applicable standards mentioned in Appendix 6 to this annex (communication with external tester).
CAN based wired communication
The communication speed on the wired data link of the OBD system shall be either 250 kbps or 500 kbps. It is the manufacturer's responsibility to select the baud-rate and to design the OBD system according to the requirements specified in the standards mentioned in Appendix 6 to this annex, and referred to in this annex. The OBD system shall be tolerant against the automatic detection between these two baud-rates exercised by the external test equipment. The connection interface between the vehicle and the external diagnostic test equipment (e.g. scan-tool) shall be standardised and shall meet all of the requirements of ISO 15031-3 Type A (12 VDC power supply), Type B (24 VDC power supply) or SAE J1939-13 (12 or 24 VDC power supply).
Reserved for TCP/IP (Ethernet) based wired communication.
Connector location
The connector shall be located in the driver's side foot-well region of the vehicle interior in the area bound by the driver's side of the vehicle and the driver's side edge of the centre console (or the vehicle centreline if the vehicle does not have a centre console) and at a location no higher than the bottom of the steering wheel when in the lowest adjustable position. The connector may not be located on or in the centre console (i.e. neither on the horizontal faces near the floor-mounted gear selector, parking brake lever, or cup holders nor on the vertical faces near the stereo/radio, climate system, or navigation system controls). The location of the connector shall be capable of being easily identified and accessed (e.g. to connect an off-board tool). For vehicles equipped with a driver's side door, the connector shall be capable of being easily identified and accessed by someone standing (or "crouched") outside the driver's side of the vehicle with the driver's side door open. The Type Approval Authority may approve upon request of the manufacturer an alternative location provided the installation position shall be easily accessible and protected from accidental damage during normal conditions of use, e.g. the location as described in ISO 15031 series of standards. If the connector is covered or located in a specific equipment box, the cover or the compartment door must be removable by hand without the use of any tools and be clearly labelled "OBD" to identify the location of the connector. The manufacturer may equip vehicles with additional diagnostic connectors and data-links for manufacturer-specific purposes other than the required OBD functions. If the additional connector conforms to one of the standard diagnostic connectors allowed in Appendix 6 to this annex, only the connector required by this annex shall be clearly labelled "OBD" to distinguish it from other similar connectors.
Annex 9B
Erasing / resetting OBD information by a scan-tool
On request of the scan tool, the following data shall be erased or reset to the value specified in this annex from the computer memory.
OBD information data Erasable Resetable9
Malfunction indicator status X
Readiness of the OBD system X
Number of engine operating hours since the malfunction indicator has been activated X (continuous MI counter)
All DTCs X
The value of the B1 counter with the highest X number of engine operating hours
The number of engine operating hours from X the B1-counter(s)
The freeze frame data requested by this annex X
OBD information shall not be erased by disconnection of the vehicle's battery(s).
Electronic security
Any vehicle with an emission control unit must include features to deter modification, except as authorized by the manufacturer. The manufacturer shall authorize modifications if these modifications are necessary for the diagnosis, servicing, inspection, retrofitting or repair of the vehicle. Any reprogramable computer codes or operating parameters shall be resistant to tampering and afford a level of protection at least as good as the provisions in ISO 15031-7 (SAE J2186) or J1939-73 provided that the security exchange is conducted using the protocols and diagnostic connector as prescribed in this annex. Any removable calibration memory chips shall be potted, encased in a sealed container or protected by electronic algorithms and shall not be changeable without the use of specialised tools and procedures. Computer-coded engine operating parameters shall not be changeable without the use of specialised tools and procedures (e.g. soldered or potted computer components or sealed (or soldered) computer enclosures). Manufacturers shall take adequate steps to protect the maximum fuel delivery setting from tampering while a vehicle is in-service. Manufacturers may apply to the Type Approval Authority for an exemption from one of these requirements for those vehicles that are unlikely to require protection. The criteria that the Type Approval Authority will evaluate in
To the value specified in the appropriate section of this annex.
Annex 9B
considering an exemption will include, but are not limited to, the current availability of performance chips, the high-performance capability of the vehicle and the projected sales volume of the vehicle. Manufacturers using programmable computer code systems (e.g. electrical erasable programmable read-only memory, EEPROM) shall deter unauthorized reprogramming. Manufacturers shall include enhanced tamper- protection strategies and write protect features requiring electronic access to an off-site computer maintained by the manufacturer. Alternative methods giving an equivalent level of tamper protection may be approved by the Type Approval Authority
Durability of the OBD system
The OBD system shall be designed and constructed so as to enable it to identify types of malfunctions over the complete life of the vehicle or engine system. Any additional provisions addressing the durability of OBD systems are contained in this annex. An OBD system shall not be programmed or otherwise designed to partially or totally deactivate based on age and/or mileage of the vehicle during the actual life of the vehicle, nor shall the system contain any algorithm or strategy designed to reduce the effectiveness of the OBD system over time.
5.Performance requirements
Thresholds
The OTLs for the applicable monitoring criteria defined in Appendix 3 to this annex are defined in the main part of this Regulation
Temporary disablement of the OBD system
Approval authorities may approve that an OBD system be temporarily disabled under the conditions specified in the following sub-paragraphs. At the time of type approval, the manufacturer shall provide the Type Approval Authority with the detailed description of each of the OBD system's temporary disablement strategies and the data and/or engineering evaluation demonstrating that monitoring during the applicable conditions would be unreliable or impractical. In all cases, monitoring shall resume once the conditions justifying temporary disablement are no longer present.
Engine/vehicle operational safety
Manufacturers may request approval to disable the affected OBD monitoring systems when operational safety strategies are activated. The OBD monitoring system is not required to evaluate components during malfunction if such evaluation would result in a risk to the safe use of the vehicle.
Annex 9B
Ambient temperature and altitude conditions
Manufacturers may request approval to disable OBD system monitors:
(a) At ambient temperatures below 266 K (-7 degrees Celsius) in the case where the coolant temperature has not reached a minimum temperature of at least 333 K (60 degrees Celsius); or
(b) At ambient temperatures below 266K (-7 degrees Celsius) in the case of frozen reagent; or
(c) At ambient temperatures above 308 K (35 degrees Celsius); or
(d) At elevations above 2,500 meters above sea level. A manufacturer may further request approval that an OBD system monitor be temporarily disabled at other ambient temperatures and altitude conditions upon determining that the manufacturer has demonstrated with data and/or an engineering evaluation that misdiagnosis would occur at those ambient conditions because of its effect on the component itself (e.g. component freezing, effect on the compatibility with sensor tolerances). Note: Ambient conditions may be estimated by indirect methods. For example ambient temperature conditions may be determined based on intake air temperature.
Low fuel level
Manufacturers may request approval to disable monitoring systems that are affected by low fuel level / pressure or running out of fuel (e.g. diagnosis of a malfunction of the fuelling system or misfiring) as follows:
Diesel Gas
NG LPG
(a) The low fuel level considered for such a disablement shall not exceed 100 litres or 20 per cent of the X X nominal capacity of the fuel tank, whichever is lower.
(b) The low fuel pressure in the tank considered for such a disablement shall not exceed 20 per cent of the X usable range of fuel tank pressure.
Vehicle battery or system voltage levels
Manufacturers may request approval to disable monitoring systems that can be affected by vehicle battery or system voltage levels.
Low voltage
For monitoring systems affected by low vehicle battery or system voltages, manufacturers may request approval to disable monitoring systems when the battery or system voltage is below 90 per cent of the nominal voltage (or 11.0 volts for a 12 volt battery, 22.0 volts for a 24 volt battery). Manufacturers may request approval to utilize a voltage threshold higher than this value to disable system monitoring.
Annex 9B
The manufacturer shall demonstrate that monitoring at the voltages would be unreliable and that either operation of a vehicle below the disablement criteria for extended periods of time is unlikely or the OBD system monitors the battery or system voltage and will detect a malfunction at the voltage used to disable other monitors.
High voltage
For emission related monitoring systems affected by high vehicle battery or system voltages, manufacturers may request approval to disable monitoring systems when the battery or system voltage exceeds a manufacturer-defined voltage. The manufacturer shall demonstrate that monitoring above the manufacturer- defined voltage would be unreliable and that either the electrical charging system/alternator warning light is illuminated (or voltage gauge is in the "red zone") or the OBD system monitors the battery or system voltage and will detect a malfunction at the voltage used to disable other monitors.
Active PTO (power take-off units)
The manufacturer may request approval to temporarily disable affected monitoring systems in vehicles equipped with a PTO unit, under the condition where that PTO unit is temporarily active.
Forced regeneration
The manufacturer may request approval to disable the affected OBD monitoring systems during the forced regeneration of an emission control system downstream of the engine (e.g. a particulate filter).
Auxillary Emissions Strategy (AES)
The manufacturer may request approval to disable OBD system monitors during the operation of an AES, including MECS, under conditions not already covered in paragraph 5.2. if the monitoring capability of a monitor is affected by the operation of an AES.
Re-fuelling
After a refuelling, the manufacturer of a gaseous-fuelled vehicle may temporarily disable the OBD system when the system has to adapt to the recognition by the ECU of a change in the fuel quality and composition. The OBD system shall be re-enabled as soon as the new fuel is recognized and the engine parameters are readjusted. This disablement shall be limited to a maximum of 10 minutes.
6.Demonstration requirements
The basic elements for demonstrating the compliance of an OBD system with the requirements of this annex are as follows:
(a) Procedure for selecting the OBD-parent engine system. The OBD- parent engine system is selected by the manufacturer in agreement with the Type Approval Authority;
Annex 9B
(b) Procedure for demonstrating the classification of a malfunction. The manufacturer submits to the Type Approval Authority the classification of each malfunction for that OBD-parent engine system and the necessary supporting data in order to justify each classification;
(c) Procedure for qualifying a deteriorated component. The manufacturer shall provide, on request of the Type Approval Authority, deteriorated components for OBD testing purposes. These components are qualified on the basis of supporting data provided by the manufacturer;
(d) Procedure for selecting the reference fuel in case of a gas engine.
Emission-OBD family
The manufacturer is responsible for determining the composition of an emission-OBD family. Grouping engine systems within an emission-OBD family shall be based on good engineering judgement and be subject to approval by the Type Approval Authority. Engines that do not belong to the same engine family may still belong to the same emission-OBD family.
Parameters defining an emission-OBD family
An emission-OBD family is characterised by basic design parameters that shall be common to engine systems within the family. In order that engine systems are considered to belong to the same OBD- engine family, the following list of basic parameters shall be similar:
(a) Emission control systems;
(b) Methods of OBD monitoring;
(c) Criteria for performance and component monitoring;
(d) Monitoring parameters (e.g. frequency). These similarities shall be demonstrated by the manufacturer by means of relevant engineering demonstration or other appropriate procedures and subject to the approval of the Type Approval Authority. The manufacturer may request approval by the Type Approval Authority of minor differences in the methods of monitoring/diagnosing the engine emission control system due to engine system configuration variation, when these methods are considered similar by the manufacturer and:
(a) They differ only to match specificities of the considered components (e.g. size, exhaust flow, etc.); or
(b) Their similarities are based on good engineering judgement.
OBD-parent engine system
Compliance of an emission-OBD family with the requirements of this annex is achieved by demonstrating the compliance of the OBD-parent engine system of this family.
Annex 9B
The selection of the OBD-parent engine system is made by the manufacturer and subject to the approval of the Type Approval Authority. Prior to testing the Type Approval Authority may decide to request the manufacturer to select an additional engine for demonstration. The manufacturer may also propose to the Type Approval Authority to test additional engines to cover the complete emission-OBD family.
Procedures for demonstrating the malfunction classification
The manufacturer shall provide the documentation justifying the proper classification of each malfunction to the Type Approval Authority. This documentation shall include a failure analysis (for example elements of a "failure mode and effect analysis") and may also include:
(a) Simulation results;
(b) Test results;
(c) Reference to previously approved classification. In the following paragraphs the requirements for demonstrating the correct classification are listed, including requirements for testing. The minimum number of tests is four and the maximum number of tests is four times the number of engine families considered within the emission OBD family. The Type Approval Authority may decide to curtail the test at any time before this maximum number of failure tests has been reached. In specific cases where the classification testing is not possible (for example, if an MECS is activated and the engine cannot run the applicable test, etc.), the malfunction may be classified based on technical justification. This exception shall be documented by the manufacturer and is subject to the agreement of the Type Approval Authority.
Demonstration of classification into Class A The classification by the manufacturer of a malfunction into Class A shall not be subject to a demonstration test. If the Type Approval Authority disagrees with a manufacturer's classification of a malfunction as Class A, the Type Approval Authority requires the classification of the malfunction into Class B1, B2 or C, as appropriate. In that case the approval document shall record that the malfunction classification has been assigned according to the request of the Type Approval Authority.
Demonstration of classification into Class B1 (distinguishing between A and B1) In order to justify the classification of a malfunction into Class B1 the documentation shall clearly demonstrate that, in some circumstances 10, the malfunction results in emissions that are lower than the OTLs.
Examples of circumstances that may influence if and when OTLs are exceeded are the age of the engine system or whether the test is conducted with a new or aged component.
Annex 9B
In the case that the Type Approval Authority requires an emission test for demonstrating the classification of a malfunction into Class B1 the manufacturer shall demonstrate that the emissions due to that particular malfunction are, in selected circumstances, below the OTLs:
(a) The manufacturer selects the circumstances of the test in agreement with the Type Approval Authority;
(b) The manufacturer shall not be required to demonstrate that in other circumstances the emissions due to the malfunction are actually above the OTLs. If the manufacturer fails to demonstrate the classification as Class B1, the malfunction is classified as Class A.
Demonstration of classification into Class B1 (distinguishing between B2 and B1) If the Type Approval Authority disagrees with a manufacturer's classification of a malfunction as Class B1 because it considers that the OTLs are not exceeded, the Type Approval Authority requires the reclassification of that malfunction into Class B2 or C. In that case the approval documents shall record that the malfunction classification has been assigned according to the request of the Type Approval Authority.
Demonstration of classification into Class B2 (distinguishing between B2 and B1) In order to justify the classification of a malfunction into Class B2 the manufacturer shall demonstrate that emissions are lower than the OTLs. In case the Type Approval Authority disagrees with the classification of a malfunction as Class B2 because it considers that the OTLs are exceeded, the manufacturer may be required to demonstrate by testing that the emissions due to the malfunction are below the OTLs. If the test fails, then the Type Approval Authority shall require the reclassification of that malfunction into A or B1 and the manufacturer shall subsequently demonstrate the appropriate classification and the documentation shall be updated.
Demonstration of classification into Class B2 (distinguishing between B2 and C) If the Type Approval Authority disagrees with a manufacturer's classification of a malfunction as Class B2 because it considers the regulated emission limits are not exceeded, the Type Approval Authority requires the reclassification of that malfunction into Class C. In that case the approval documents shall record that the malfunction classification has been assigned according to the request of the Type Approval Authority.
Demonstration of classification into Class C
In order to justify the classification of a malfunction into Class C the manufacturer shall demonstrate that emissions are lower than the regulated emission limits.
Annex 9B
In case the Type Approval Authority disagrees with the classification of a malfunction as Class C the manufacturer may be required to demonstrate by testing that the emissions due to the malfunction are below the regulated emission limits. If the test fails, then the Type Approval Authority shall request the reclassification of that malfunction and the manufacturer shall subsequently demonstrate the appropriate reclassification and the documentation shall be updated.
Procedures for demonstrating the OBD performance
The manufacturer shall submit to the Type Approval Authority a complete documentation package justifying the compliance of the OBD system as regards its monitoring capability, which may include:
(a) Algorithms and decision charts;
(b) Tests and/or simulation results;
(c) Reference to previously approved monitoring systems, etc. In the following paragraphs the requirements for demonstrating the OBD performance are listed, including requirements for testing. The number of tests shall be four times the number of engine families considered within the emission OBD family, but shall not be less than eight. The monitors selected shall reflect the different types of monitors mentioned in paragraph 4.2. (i.e. emission threshold monitoring, performance monitoring, total functional failure monitoring, or component monitoring) in a well balanced manner. The monitors selected shall also reflect the different items listed in Appendix 3 to this annex in a well balanced manner.
Procedures for demonstrating the OBD performance by testing
In addition to the supporting data referred to in paragraph 6.3., the manufacturer shall demonstrate the proper monitoring of specific emission control systems or components by testing them on an engine test-bed according to the test procedures specified in paragraph 7.2. of this annex. In that case, the manufacturer shall make available the qualified deteriorated components or the electrical device which would be used to simulate a malfunction. The proper detection of the malfunction by the OBD system and its proper response to that detection (cf. MI indication, DTC storage, etc.) shall be demonstrated according to paragraph 7.2.
Procedures for qualifying a deteriorated component (or system)
This paragraph applies to the cases where the malfunction selected for an OBD demonstration test is monitored against tailpipe emissions 11 (emission threshold monitoring - see paragraph 4.2.) and it is required that the manufacturer demonstrates, by an emission test, the qualification of that deteriorated component.
This paragraph will be extended to other monitors than emission threshold monitors at a later stage.
Annex 9B
In very specific cases the qualification of deteriorated components or systems by testing may not be possible (for example, if an MECS is activated and the engine cannot run the applicable test, etc.). In such cases, the deteriorated component shall be qualified without testing. This exception shall be documented by the manufacturer and is subject to the agreement of the Type Type Approval Authority.
Procedure for qualifying a deteriorated component used to demonstrate the detection of classes A and B1 malfunctions
Emission threshold monitoring
In the case the malfunction selected by the Type Approval Authority results in tailpipe emissions that may exceed an OBD threshold limit, the manufacturer shall demonstrate by an emission test according to paragraph 7. that the deteriorated component or device does not result in the relevant emission exceeding its OTL by more than 20 per cent.
Performance monitoring
At the request of the manufacturer and with the agreement of the Type Approval Authority, in the case of performance monitoring, the OTL may be exceeded by more than 20 per cent. Such request shall be justified on a case by case basis.
Component monitoring
In the case of component monitoring, a deteriorated component is qualified without reference to the OTL.
Qualification of deteriorated components used to demonstrate the detection of Class B2 malfunctions In the case of Class B2 malfunctions, and upon request of the Type Approval Authority, the manufacturer shall demonstrate by an emission test according to paragraph 7. that the deteriorated component or device does not lead the relevant emission to exceed its applicable OTL.
Qualification of deteriorated components used to demonstrate the detection of Class C malfunctions In the case of Class C malfunctions, and upon request of the Type Approval Authority, the manufacturer shall demonstrate by an emission test according to paragraph 7. that the deteriorated component or device does not lead the relevant emission to exceed its applicable regulated emission limit.
Test report
The test report shall contain, at a minimum, the information set out in Appendix 4 to this annex.
Approval of an OBD system containing deficiencies
Approval authorities may approve upon request of a manufacturer an OBD system even though the system contains one or more deficiencies. In considering the request, the Type Approval Authority shall determine whether compliance with the requirements of this annex is feasible or unreasonable.
Annex 9B
The Type Approval Authority shall take into consideration data from the manufacturer that details such factors as, but not limited to, technical feasibility, lead time and production cycles including phase-in or phase-out of engines designs and programmed upgrades of computers, the extent to which the resultant OBD system will be effective in complying with the requirements of this annex and that the manufacturer has demonstrated an acceptable level of effort toward meeting the requirements of the annex. The Type Approval Authority will not accept any deficiency request that includes the complete lack of a required diagnostic monitor (i.e. a complete lack of the monitors required in Appendix 3 to this annex).
Deficiency period
A deficiency is granted for a period of one year after the date of approval of the engine system. If the manufacturer can adequately demonstrate to the Type Approval Authority that substantial engine modifications and additional lead time would be necessary to correct the deficiency, then this deficiency can be granted again for an additional one year, provided that the total deficiency period does not exceed three years (i.e. three times one year deficiency allowance is permitted). The manufacturer cannot apply for a renewal of the deficiency period.
Procedure for selecting the reference fuel in case of a gas engine
Demonstration of the OBD performance and malfunction classification shall be performed by using one of the reference fuels mentioned in Annex 5 on which the engine is designed to operate. The selection of this reference fuel is done by the Type Approval Authority , who shall provide sufficient time for the test laboratory to supply the selected reference fuel.
7.Test procedures
Testing process
The demonstration by testing of the proper malfunction classification and the demonstration by testing of the proper monitoring performance of an OBD system are issues that shall be considered separately during the testing process. For example, a Class A malfunction will not require a classification test while it may be subject to an OBD performance test. Where appropriate, the same test may be used to demonstrate the correct classification of a malfunction, the qualification of a deteriorated component provided by the manufacturer and the correct monitoring by the OBD system. The engine system on which the OBD system is tested shall comply with the emission requirements of this Regulation.
Testing process for demonstrating the malfunction classification
When, according to paragraph 6.2., the Type Approval Authority requests the manufacturer to justify by testing the classification of a specific malfunction, the compliance demonstration will consist of a series of emission tests.
Annex 9B
According to paragraph 6.2.2., when testing is required by the Type Approval Authority to justify the classification of a malfunction into Class B1 rather than in Class A, the manufacturer shall demonstrate that the emissions due to that particular malfunction are, in selected circumstances, below the OTLs:
(a) The manufacturer selects these circumstances of test in agreement with the Type Approval Authority;
(b) The manufacturer shall not be required to demonstrate that in other circumstances the emissions due to the malfunction are actually above the OTLs. The emission test may be repeated upon request of the manufacturer up to three times. If any of these tests leads to emissions below the considered OTL, then the malfunction classification into Class B1 shall be approved. When testing is required by the Type Approval Authority to justify the classification of a malfunction into Class B2 rather than in Class B1 or into Class C rather than in Class B2, the emission test shall not be repeated. If the emissions measured in the test are above the OTL or the emission limit, respectively, then the malfunction shall require a reclassification. Note: According to paragraph 6.2.1., this paragraph does not apply to malfunctions classified into Class A.
Testing process for demonstrating the OBD performance
When the Type Approval Authority requests to test the OBD system performance according to paragraph 6.3., the compliance demonstration shall consist of the following phases:
(a) A malfunction is selected by the Type Approval Authority and a corresponding deteriorated component or system shall be made available by the manufacturer;
(b) When appropriate and if requested, the manufacturer shall demonstrate by an emission test that the deteriorated component is qualified for a monitoring demonstration;
(c) The manufacturer shall demonstrate that the OBD system responds in a manner that complies with the provisions of this annex (i.e. MI indication, DTC storage, etc.) At the latest by the end of a series of OBD test-cycles.
Qualification of the deteriorated component
When the Type Approval Authority requests the manufacturer to qualify a deteriorated component by testing according to paragraph 6.3.2., this demonstration shall be made by performing an emissions test. If it is determined that the installation of a deteriorated component or device on an engine system means that a comparison with the OBD threshold limits is not possible (e.g. because the statistical conditions for validating the applicable emission test cycle are not met), the malfunction of that component or device may be considered as qualified upon the agreement of the Type Approval Authority based on technical rationale provided by the manufacturer.
Annex 9B
In the case that the installation of a deteriorated component or device on an engine means that the full load curve (as determined with a correctly operating engine) cannot be attained during the test, the deteriorated component or device may be considered as qualified upon the agreement of the Type Approval Authority based on technical rationale provided by the manufacturer.
Malfunction detection
Each monitor selected by the Type Approval Authority to be tested on an engine test-bed, shall respond to the introduction of a qualified deteriorated component in a manner that meets the requirements of this annex within two consecutive OBD test-cycles according to paragraph 7.2.2. of this annex. When it has been specified in the monitoring description and agreed by the Type Approval Authority that a specific monitor needs more than two operating sequences to complete its monitoring, the number of OBD test- cycles may be increased according to the manufacturer's request. Each individual OBD test-cycle in the demonstration test shall be separated by an engine shut-off. The time until the next start-up shall take into consideration any monitoring that may occur after engine shut-off and any necessary condition that must exist for monitoring to occur at the next start up. The test is considered complete as soon as the OBD system has responded in a manner that meets the requirements of this annex.
Applicable tests
In the context of this annex:
(a) The emission test-cycle is the test-cycle used for the measurement of the regulated emissions when qualifying a deteriorated component or system;
(b) The OBD test-cycle is the test-cycle used to demonstrate the capacity of the OBD monitors to detect malfunctions.
Emission test cycle
The test-cycle considered in this annex for measuring emissions is the WHTC test-cycle as described in Annex 4.
OBD test cycle
The OBD test-cycle considered in this annex is the hot part of the WHTC cycle as described in Annex 4. On request of the manufacturer and after approval of the Type Approval Authority , an alternative OBD test-cycle can be used (e.g. the cold part of the WHTC cycle) for a specific monitor. The request shall contain documentation (technical considerations, simulation, test results, etc.) showing that:
(a) The requested test-cycle appropriate to demonstrate monitoring occurs under real world driving conditions; and
(b) The hot part of the WHTC cycle appears as less appropriate for the considered monitoring (e.g. fluid consumption monitoring).
Annex 9B
Test operating conditions
The conditions (i.e. temperature, altitude, fuel quality etc.) for conducting the tests referred to in paragraphs 7.2.1. and 7.2.2. shall be those required for operating the WHTC test cycle as described in Annex 4. In the case of an emission test aimed at justifying the classification of a specific malfunction into Class B1, the test operating conditions may, per decision of the manufacturer, deviate from the ones in the paragraphs above according to paragraph 6.2.2.
Demonstration process for performance monitoring
The manufacturer may use the demonstration requirements as set out in Appendix 7 to this annex in case of performance monitoring. Type Approval authorities may approve a manufacturer's use of a type of performance monitoring technique other than the one referred to in Appendix 7 to this annex. The chosen type of monitoring shall be demonstrated by the manufacturer by a robust technical case based upon the design characteristics, or by presentation of test results, or by reference to previous approvals, or by some other acceptable method, to be at least as robust, timely and efficient as the ones mentioned in Appendix 7 to this annex.
Test reports
The test report shall contain, at a minimum, the information set out in Appendix 4.
8.Documentation requirements
Documentation for purpose of approval
The manufacturer shall provide a documentation package that includes a full description of the OBD system. The documentation package shall be made available in two parts:
(a) A first part, which may be brief, provided that it exhibits evidence concerning the relationships between monitors, sensors/actuators, and operating conditions (i.e. describes all enable conditions for monitors to run and disable conditions that cause monitors not to run). The documentation shall describe the functional operation of the OBD, including the malfunction ranking within the hierarchical classification. This material shall be retained by the Type Approval Authority. This information may be made available to interested parties upon request;
(b) A second part containing any data, including details of qualified deteriorated components or systems and associated test results, which are used as evidence to support the decision process referred to above, and a listing of all input and output signals that are available to the engine system and monitored by the OBD system. This second part shall also outline each monitoring strategy and the decision process.
Annex 9B
This second part shall remain strictly confidential. It may be kept by the Type Approval Authority or, at the discretion of the Type Approval Authority, may be retained by the manufacturer but shall be made open for inspection by the Type Approval Authority at the time of approval or at any time during the validity of the approval.
Documentation associated with each monitored component or system
The documentation package included in the second part shall contain but shall not be limited to the following information for each monitored component or system:
(a) The malfunctions and associated DTC(s);
(b) The monitoring method used for malfunction detection;
(c) The parameters used and the conditions necessary for malfunction detection and when applicable the fault criteria limits (performance and component monitoring);
(d) The criteria for storing a DTC;
(e) The monitoring "time length" (i.e. the operation time/procedure necessary to complete the monitoring) and the monitoring "frequency" (e.g. continuous, once per trip, etc.).
Documentation associated with the malfunction classification
The documentation package included in the second part shall contain but shall not be limited to the following information for malfunction classification: The malfunction classification of each DTC shall be documented. This classification may be different for different engine types (e.g. different engine ratings) within the same emission-OBD family. This information shall include the technical justification required in paragraph 4.2. of this annex for classification into Class A, Class B1 or Class B2.
Documentation associated with the emission-OBD family
The documentation package included in the second part shall contain but shall not be limited to the following information for emission OBD-family: A description of the emission-OBD family shall be provided. This description shall include a list and a description of the engine types within the family, the description of the OBD-parent engine system, and all elements that characterise the family according to paragraph 6.1.1. of this annex. In the case where the emission-OBD family includes engines belonging to different engine families, a summary description of these engine families shall be provided. In addition, the manufacturer shall provide a list of all electronic input, output and identification of the communication protocol utilized by each emission- OBD family.
Documentation for installing in a vehicle an OBD equipped engine system
The engine manufacturer shall include in the installation documents of its engine system the appropriate requirements that will ensure the vehicle, when
Annex 9B
used on the road or elsewhere as appropriate, will comply with the requirements of this annex. This documentation shall include but is not limited to:
(a) The detailed technical requirements, including the provisions ensuring the compatibility with the OBD system of the engine system;
(b) The verification procedure to be completed. The existence and the adequacy of such installation requirements may be checked during the approval process of the engine system. Note: In the case a vehicle manufacturer applies for a direct approval of the installation of the OBD system on the vehicle, this documentation is not required.
Annex 9B – Appendix 1
Annex 9B - Appendix 1
Approval of installation of OBD systems This appendix considers the case where the vehicle manufacturer requests approval of the installation on a vehicle of (an) OBD system(s) within an emission OBD family that is (are) certified to the requirements of this annex In this case, and in addition to the general requirements of this annex, a demonstration of the correct installation is required. This demonstration shall be done on the basis of the appropriate element of design, results of verification tests, etc. and address the conformity of the following elements to the requirements of this annex:
(a) The installation on-board the vehicle as regards its compatibility with the OBD system of the engine-system;
(b) The MI (pictogram, activation schemes, etc.);
(c) The wired communication interface. Correct MI illumination, information storage and on-board off-board OBD communication will be checked. But any check shall not force dismounting the engine system (e.g. an electric disconnection may be selected).
Annex 9B – Appendix 2
Annex 9B - Appendix 2
Malfunctions - Illustration of the DTC status - Illustration of the MI and counters activation schemes This appendix aims at illustrating the requirements set in paragraphs 4.3. and 4.6.5. of this annex. It contains the following figures:
Where the control of the EGR flow rate is performed by means of a closed-loop system, the OBD system shall detect a malfunction when the EGR system cannot increase the EGR flow to achieve the demanded flow rate. Such a malfunction shall not be classified as a Class C failure.
Where the control of the EGR flow rate is performed by means of an open-loop system, the OBD system shall detect a malfunction when the system has no detectable amount of EGR flow when EGR flow is expected. Such a malfunction shall not be classified as a Class C failure.
(c2) EGR cooler under cooling performance ( total functional failure monitoring)
Annex 9B – Appendix 3
In the case where total failure of the EGR cooler system's ability to achieve the manufacturer's specified cooling performance would not result in the monitoring system detecting a failure (because the resulting increase in emissions would not reach the OBD threshold limit for any pollutant), the OBD system shall detect a malfunction when the system has no detectable amount of EGR cooling. Such a malfunction shall not be classified as a Class C failure. Appendix 3 - Item 7 Fuel System monitoring The OBD system shall monitor the following elements of the fuel system on engines so- equipped for proper operation: Diesel Gas
(a) Fuel system pressure control: fuel system ability to achieve the commanded fuel pressure in closed loop X control – performance monitoring.
(b) Fuel system pressure control: fuel system ability to achieve the commanded fuel pressure in closed loop control in the case where the system is so constructed that X the pressure can be controlled independently of other parameters – performance monitoring.
(c) Fuel injection timing: fuel system ability to achieve the commanded fuel timing for at least one of the injection X events when the engine is equipped with the appropriate sensors – performance monitoring.
(d) Fuel injection system: ability to maintain the desired air- fuel ratio (incl. but not limited to self adaptation features) X
– performance monitoring.
Annex 9B – Appendix 3
Appendix 3 - Item 8 Air handling and turbocharger/Boost pressure control system The OBD system shall monitor the following elements of the Air handling and turbocharger/Boost pressure control system on engines so-equipped for proper operation: Diesel Gas
(a1) Turbo under/over boost: turbo boost system's ability to maintain the commanded boost pressure, detecting both X "boost pressure too low" and "boost pressure too high" conditions – emission threshold monitoring.
(a2) Turbo under/over boost: turbo boost system's ability to maintain the commanded boost pressure, detecting both X "boost pressure too low" and "boost pressure too high" conditions – performance monitoring.
(a3) Turbo under boost: turbo boost system's ability to maintain the commanded boost pressure, detecting "boost pressure too X X low" conditions – total functional failure or performance monitoring as specified in this item.
(b) Variable Geometry Turbo (VGT) slow response: VGT system's ability to achieve the commanded geometry within a X X manufacturer specified time-performance monitoring.
(c) Charge air cooling: Charge air cooling system efficiency - X X total functional failure.
(a3) Turbo under boost (total functional failure monitoring)
In the case where the emissions would not exceed the OBD threshold limits even upon total failure of the boost system's ability to maintain the demanded boost pressure and the control of the boost pressure is performed by means of a closed- loop system, the OBD system shall detect a malfunction when the boost system cannot increase the boost pressure to achieve the demanded boost pressure. Such a malfunction shall not be classified as a Class C failure.
In the case where the emissions would not exceed the OBD threshold limits even upon total failure of the boost system's ability to maintain the demanded boost pressure and the control of the boost pressure is performed by means of an open- loop system, the OBD system shall detect a malfunction when the system has no detectable amount of boost pressure when boost pressure is expected. Such a malfunction shall not be classified as a Class C failure. Appendix 3 - Item 9 Variable Valve Timing (VVT) System The OBD system shall monitor the following elements of the Variable Valve Timing (VVT) System on engines so-equipped for proper operation:
(a) VVT target error: VVT system’s ability to achieve the commanded valve timing - performance monitoring;
Annex 9B – Appendix 3
(b) VVT slow response: VVT system’s ability to achieve the commanded valve timing within a manufacturer specified time interval following the command-performance monitoring. Appendix 3 - Item 10 Misfire Monitoring
Diesel Gas
(a) No prescriptions. X
(b) Misfire that may cause catalyst damage (e.g. by monitoring a certain percentage of misfiring in a certain period of time) – X performance monitoring.
Appendix 3 - Item 11 Crankcase Ventilation System Monitoring No prescriptions. Appendix 3 - Item 12 Engine Cooling System Monitoring The OBD system shall monitor the following elements of the engine cooling system for proper operation:
(a) Engine coolant temperature (thermostat): Stuck open thermostat. Manufacturers need not monitor the thermostat if its failure will not disable any other OBD monitors - total functional failure. Manufacturers need not monitor the engine coolant temperature or the engine coolant temperature sensor if the engine coolant temperature or the engine coolant temperature sensor is not used to enable closed-loop/feedback control of any emissions control systems and/or will not disable any other monitor. Manufacturers may suspend or delay the monitor for the time to reach close loop to enable temperature if the engine is subjected to conditions that could lead to false diagnosis (e.g. vehicle operation at idle for more than 50 to 75 per cent of the warm-up time). Appendix 3 - Item 13 Exhaust gas and oxygen sensors monitoring The OBD system shall monitor:
Diesel Gas
(a) The electrical elements of the exhaust gas sensors on engines so-equipped for proper operation according to item 1 to this X X appendix – component monitoring.
(b) Both the primary and secondary (fuel control) oxygen sensors. These sensors are considered as exhaust gas sensors to be X monitored for proper operation according to item 1 to this appendix – component monitoring.
Annex 9B – Appendix 3
Appendix 3 - Item 14 Idle speed control system monitoring The OBD system shall monitor the electrical elements of the idle speed control systems on engines so-equipped for proper operation according to item 1 to this appendix. Appendix 3 – Item 15 Three-way catalyst The OBD system shall monitor the three-way catalyst on engines so-equipped for proper operation:
Diesel Gas
(a) Three-way Catalyst Conversion efficiency: the catalyst X ability to convert NOx and CO – performance monitoring.
Annex 9B – Appendix 4
Annex 9B - Appendix 4
Technical compliance report This report is issued by the Type Approval Authority, according to paragraphs 6.3.3. and
of this annex, after examination of an OBD system or an emission OBD family when that system or family complies with the requirements of this appendix. The exact reference (including its version number) of this appendix shall be included in this report. The exact reference (including its version number) to this Regulation shall be included. This report contains a cover page indicating the final compliance of the OBD system or emission OBD family and the following 5 items: Item 1 Information concerning the OBD system Item 2 Information concerning the conformity of the OBD system Item 3 Information concerning deficiencies Item 4 Information concerning demonstration tests of the OBD system Item 5 Test protocol The content of the technical report, including its Items, shall, at a minimum, include the elements given in the following examples. This report shall state that reproduction or publication in extracts of this report is not permitted without the written consent of the undersigned Type Approval Authority. Final compliance report The documentation package and the herewith described OBD system / emission OBD family comply with the requirements of the following regulation: Regulation … / version …/ enforcement date … / type of fuel … This Regulation transposes the following gtr: gtr …/ A + B / version …/ date …. The technical compliance report encompasses … pages. Author (name and signature) Type Approval Authority (name, stamp)
Annex 9B – Appendix 4
Item 1 to the technical compliance report (example) Information concerning the OBS system
1.Type of requested approval
Requested Approval
- Approval of an individual OBD system YES / NO
- Approval of an emission OBD family YES / NO
- Approval of an OBD system as member of a certified emission OBD family YES / NO
- Extension to include a new engine system into an emission OBD family
- Extension to address a design change that affects the OBD system YES / NO
- Extension to address a malfunction reclassification YES / NO YES / NO
2.Information concerning the OBD system
Approval of an individual OBD system
- OBD description (issued by the manufacturer): reference and date
Approval of an emission OBD family applicable, see paragraph 6.1.)
Approval of an OBD system as member of a certified emission OBD family applicable, see paragraph 6.1.) (when applicable)
- Type1 of the engine system concerned by the new OBD system
As reported in the approval document.
Annex 9B – Appendix 4
Extension to include a new engine system into an emission OBD family
- List (extended if necessary) of the engine families concerned by the (extended if necessary) of the engine types1 within the emission OBD within the emission OBD family- Extended OBD description (issued by
Extension to address a design change that affects the OBD system
- List of the engine types1 concerned by the design change system within the emission OBD family date
Extension to address a malfunction reclassification
- List of the engine families (when applicable) concerned by the date
Item 2 to the technical compliance report (example) Information concerning the conformity of the OBD system
1.Documentation package
The elements provided by the manufacturer in the documentation package of the emission OBD family, are complete and comply with the requirements of paragraph 8. of this annex, on the following issues:
- Documentation associated with each monitored component or system YES / NO
- Documentation associated with each DTC YES / NO
- Documentation associated with the malfunction classification YES / NO
- Documentation associated with the emission OBD family YES / NO
- The documentation required in paragraph 8.2. of this annex for installing an OBD system in a vehicle has been provided by the manufacturer in the YES / NO documentation package, is complete, and complies with the requirements of this annex:
- The installation of the engine system equipped with the OBD system complies with Appendix 1 of this annex. YES / NO
Annex 9B – Appendix 4
2.Content of the documentation
Monitoring The monitors comply with the requirements of paragraph 4.2. of this annex: YES / NO
Classification The malfunction classification complies with the requirements of YES / NO paragraph 4.5. of this annex:
MI activation scheme According to paragraph 4.6.3. of this annex, the MI-activation scheme is: Discriminatory / The activation and the extinguishing of the malfunction indicator Non-discriminatory comply with the requirements of paragraph 4.6. of this annex: YES / NO
DTCs recording & erasing The recording and erasing of DTCs comply with the requirements of YES / NO paragraphs 4.3. and 4.4. of this annex:
Disablement of the OBD system The strategies described in the documentation package for a YES / NO momentary disconnection or disablement of the OBD system comply with the requirements of paragraph 5.2. of this annex:
Electronic system security The measures described by the manufacturer for electronic system YES / NO security comply with the requirements of paragraph 4.8. of this annex:
Item 3 to the technical compliance report (example) Information concerning deficiencies
Number of deficiencies of OBD system (ex: 4 deficiencies)
The deficiencies comply with the requirements of YES / NO paragraph 6.4. of this annex
Deficiency No. 1
- Object of the deficiency e.g. measuring of the urea concentration (SCR) within defined tolerances
- Period of the deficiency e.g. one year / six months after the date of approval
(Description of deficiencies 2 to n-1)
Deficiency No. n
- Object of the deficiency e.g. measuring of NH3 concentration behind SCR system
- Period of the deficiency e.g. one year / six months after the date of approval
Annex 9B – Appendix 4 Item 4 to the technical compliance report (example) Demonstration tests of the OBD system
1.Test result of the OBD system
Results of the tests The OBD system described in the above complying documentation package has been tested with success according to paragraph 6. of YES / NO this annex for demonstrating the compliance of monitors and of malfunction classifications as listed in item 5:
Details to the conducted demonstration tests are given in item 5.
OBD system tested on the engine test-bed
Engine
Control units concerned by this annex (incl. engine ECUs)
Diagnostic tool (scan tool used during testing)
Test information
2.Demonstration tests of the installation of the OBD system
In addition to the demonstration of the OBD system / emission OBD family, the installation of the OBD system / of the OBD YES / NO systems within the emission OBD family has been tested on a vehicle, according to the provisions of Appendix 1 to Annex 9B
Test result of the installation of the OBD system
Results of the test If the installation of the OBD system has been tested on a vehicle, YES / NO the installation of the OBD system has been tested with success according to Appendix 1 to Annex 9B
Annex 9B – Appendix 4
Tested installation
If the installation of the OBD system has been tested on a vehicle:
Tested vehicle
Diagnostic tool (scan tool used for testing)
- Manufacturer: ...
Test information
Annex 9B – Appendix 4 Item 5 to the technical compliance report (example) Test protocol Annex 9B – Appendix 5
Annex 9B - Appendix 5
Freeze frame and data stream information The following tables list the pieces of information that are considered in paragraphs 4.7.1.4. and 4.7.2. of this annex. Mandatory requirements
Freeze frame Data stream
Calculated load (engine torque as a percentage of maximum x x torque available at the current engine speed)
Engine speed x x
Engine coolant temperature (or equivalent) x x
Barometric pressure (directly measured or estimated) x x
Optional engine speed and load information
Freeze frame Data stream
Driver’s demand engine torque (as a percentage of maximum x x engine torque)
Actual engine torque (calculated as a percentage of maximum engine torque, e.g. calculated from commanded injection fuel x x quantity)
Reference engine maximum torque x
Reference maximum engine torque as a function of engine x speed
Time elapsed since engine start x x
Annex 9B – Appendix 5
Optional information, if used by the emission or the OBD system to enable or disable any OBWHSCD information
Freeze frame Data stream
Fuel level (e.g. percentage of the nominal capacity of the fuel
tank) or tank fuel pressure (e.g. percentage of the usable x x range of fuel tank pressure), as appropriate
Engine oil temperature x x
Vehicle speed x x
Status of the fuel quality adaptation (active / not active) in x case of gas engines
Engine control computer system voltage (for the main control x x chip)
Optional information, if the engine is so equipped, senses or calculates the information
Freeze frame Data stream
Absolute throttle position / intake air throttle position x x (position of valve used to regulate intake air)
Diesel fuel control system status in case of a close loop x x system (e.g. in case of a fuel pressure close loop system)
Fuel rail pressure x x
Injection control pressure (i.e. pressure of the fluid x x controlling fuel injection)
Representative fuel injection timing (beginning of first main x x injection)
Commanded fuel rail pressure x x
Commanded injection control pressure (i.e. pressure of the x x fluid controlling fuel injection)
Intake air temperature x x
Ambient air temperature x x
Turbocharger inlet / outlet air temperature (compressor and x x turbine)
Turbocharger inlet / outlet pressure (compressor and turbine) x x
Charge air temperature (post intercooler if fitted) x x
Actual boost pressure x x
Annex 9B – Appendix 5
Freeze frame Data stream
Air flow rate from mass air flow sensor x x
Commanded EGR valve duty cycle/position (provided EGR x x is so controlled)
Actual EGR valve duty cycle/position x x
PTO status (active or not active) x x
Accelerator pedal position x x
Redundant absolute pedal position x if sensed
Instantaneous fuel consumption x x
Commanded/target boost pressure (if boost pressure used to x x control turbo operation)
DPF inlet pressure x x
DPF outlet pressure x x
DPF delta pressure x x
Engine-out exhaust pressure x x
DPF inlet temperature x x
DPF outlet temperature x x
Engine-out exhaust gas temperature x x
Turbocharger/turbine speed x x
Variable geometry turbo position x x
Commanded variable geometry turbo position x x
Wastegate valve position x x
Air/fuel ratio sensor output x
Oxygen sensor output x
Secondary oxygen sensor output (when fitted) x
NOx sensor output x
Annex 9B – Appendix 6
Annex 9B - Appendix 6
Reference standard documents This appendix contains the references to the industry standards that are to be used in accordance to the provisions in this annex to provide the serial communications interface to the vehicle/engine. There are two allowed solutions identified:
(a) ISO 27145 with either ISO 15765-4 (CAN based) or with ISO 13400 (TCP/IP based);
(b) SAE J1939-73. In addition there are other ISO or SAE standards that are applicable in accordance with the provisions of this annex. Reference by this annex to ISO 27145 means reference to:
(a) ISO 27145-1 Road vehicles — Implementation of WWH-OBD communication requirements — Part 1 — General Information and use case definitions;
(b) ISO 27145-2 Road vehicles — Implementation of WWH-OBD communication requirements — Part 2 — Common emissions-related data dictionary;
(c) ISO 27145-3 Road vehicles — Implementation of WWH-OBD communication requirements — Part 3 — Common message dictionary;
(d) ISO 27145-4 Road vehicles — Implementation of WWH-OBD communication requirements — Part 4 — Connection between vehicle and test equipment. Reference by this annex to J1939-73 means reference to: J1939-73 "APPLICATION LAYER - DIAGNOSTICS", dated on year 2011. Reference by this annex to ISO 13400 means reference to:
(a) FDIS 13400-1: 2011 Road vehicles — Diagnostic communication over Internet Protocol (DoIP) — Part 1: General information and use case definition;
(b) FDIS 13400-3: 2011 Road vehicles — Diagnostic communication over Internet Protocol (DoIP) — Part 2: Network and transport layer requirements and services;
(c) FDIS 13400-3: 2011 Road vehicles — Diagnostic communication over Internet Protocol (DoIP) — Part 3: IEEE 802.3 based wired vehicle interface;
(d) [not yet finalized] 13400-4: 2011 Road vehicles — Diagnostic communication over Internet Protocol (DoIP) — Part 4: Ethernet-based high-speed data link connector.
Annex 9B – Appendix 7
Annex 9B - Appendix 7
Performance monitoring A.7.1. General A.7.1.1. This appendix sets out provisions relating to the demonstration process applicable in some cases of performance monitoring. A.7.2. Demonstration of performance monitoring A.7.2.1. Approval of the failure classification A.7.2.1.1. As specified in paragraph 4.2.1.1. of this annex, in the case of performance monitoring no correlation to actual emissions is necessary. However, the approval authority may request test data in order to verify the classification of the malfunction effects as described in paragraph 6.2. of this annex. A.7.2.2. Approval of the performance monitoring selected by the manufacturer A.7.2.2.1. In arriving at an approval decision on the choice of the performance monitoring selected by the manufacturer, the Type Approval Authority shall consider technical information provided by the manufacturer. A.7.2.2.2. The performance threshold selected by the manufacturer for the monitor under consideration shall be determined on the parent engine of the OBD engine family during a qualification test performed as follows: A.7.2.2.2.1. The qualification test is performed in the same way as specified in paragraph 6.3.2. of this annex. A.7.2.2.2.2. The decrease of performance of the component under consideration is measured and subsequently serves as the performance threshold for the parent engine of the OBD engine family. A.7.2.2.3. The performance monitoring criteria approved for the parent engine will be considered to be applicable to all other members of the OBD engine family without further demonstration. A.7.2.2.4. Upon agreement between the manufacturer and the Type Approval Authority, adaptation of the performance threshold to different members of the OBD engine family in order to cover different design parameters (for example EGR cooler size) shall be possible. Such agreement shall be based on technical elements showing its pertinence. A.7.2.2.4.1. At the request of the Type Approval Authority, a second member of the OBD engine family may be subject to the approval process described in paragraph A.7.2.2.2. A.7.2.3. Qualification of a deteriorated component A.7.2.3.1. For the purpose of demonstrating the OBD performance of the selected monitor of an OBD engine family, a deteriorated component shall be qualified on the parent engine of the OBD engine family in accordance with paragraph 6.3.2. of this annex.
Annex 9B – Appendix 7
A.7.2.3.2. In case of a second engine tested in accordance with paragraph A.7.2.2.4.1., the deteriorated component shall be qualified on that second engine in accordance with paragraph 6.3.2. of this annex. A.7.2.4. Demonstration of the OBD performance A.7.2.4.1. The demonstration of the OBD performance shall be conducted according to the requirements of paragraph 7.1.2. of this annex using the qualified deteriorated component that is qualified for use with the parent engine.
Annex 9B – Appendix 8
Annex 9B - Appendix 8
Demonstration requirements in case of performance monitoring of a wall-flow diesel particulate filter A.8.1. General A.8.1.1. This Appendix specifies the OBD demonstration process applicable in the case where the filtering process of a wall-flow diesel particulate filter (DPF) is subject to performance monitoring. A.8.1.1. A deteriorated wall-flow DPF can be created, for example, by drilling holes into the DPF substrate or by grinding the end caps of the DPF substrate. A.8.2. Qualification test A.8.2.1. Principle A.8.2.1.1. A deteriorated wall-flow DPF is considered as a "Qualified Deteriorated Component" if, under the operating conditions of the engine specified for the purpose of that test, the pressure drop ("delta pressure") across that deteriorated wall-flow DPF exceeds or is no less than 60 per cent of the pressure drop measured across a clean and non-deteriorated wall-flow DPF of the same type. A.8.2.1.1.1. The manufacturer shall demonstrate that this clean and non-deteriorated wall- flow DPF leads to the same back-pressure as the deteriorated one before its deterioration. A.8.2.2. Qualification process A.8.2.2.1. For qualifying a deteriorated wall-flow DPF, the engine equipped with that wall-flow DPF shall be operated under stabilised steady-state conditions, set at the speed and load values specified for mode 9 in the WHSC test cycle specified in Annex 4B to this Regulation (55 per cent normalised speed and 50 per cent normalised torque). A.8.2.2.2. To qualify a deteriorated wall-flow DPF as a "Qualified Deteriorated Component", the manufacturer shall demonstrate that the pressure drop across that deteriorated wall-flow DPF, measured when the engine system is operated under the conditions specified in paragraph A.8.2.2.1., is no less than the percentage of the pressure drop across a clean and non-deteriorated DPF under the same conditions which is applicable in accordance with paragraphs A.8.2.1.1. and A.8.2.1.2. of this appendix. A.8.2.3. Demonstration of the OBD performance A.8.2.3.1. The demonstration of the OBD performance shall be conducted in accordance with the requirements of paragraph 7.1.2. of this annex with the qualified deteriorated wall-flow DPF mounted on the parent engine system.
Annex 9C
Annex 9C
Technical requirements for assessing the in-use performance of on-board diagnostic systems (OBD)
1.Applicability
In its current version, this annex is only applicable to road-vehicles equipped with a compression-ignition engine.
2.Reserved
3.Definitions
"In-Use performance ratio"
The in-use performance ratio (IUPR) of a specific monitor m of the OBD system is: IUPRm = Numeratorm / Denominatorm
"Numerator"
The numerator of a specific monitor m (Numerator m) is a counter indicating the number of times a vehicle has been operated such that all monitoring conditions necessary for that specific monitor to detect a malfunction have been encountered.
"Denominator"
The denominator of a specific monitor m (Denominator m) is a counter indicating the number of vehicle driving events, taking into account conditions specific to that specific monitor.
"General Denominator"
The general denominator is a counter indicating the number of times a vehicle has been operated, taking into account general conditions.
Abbreviations
IUPR In-Use Performance Ratio IUPRm In-Use Performance Ratio of a specific monitor m
4.General requirements
The OBD system shall have the capability of tracking and recording in-use performance data (paragraph 6.) of the OBD monitors specified in this paragraph, of storing these data in computer memory and communicating them off-board upon request (paragraph 7.). The in-use performance data of a monitor consists of the numerator and denominator enabling the calculation of the IUPR.
IUPR monitors
Groups of monitors
Manufacturers shall implement software algorithms in the OBD system to individually track and report in-use performance data of the groups of monitors mentioned in Appendix 1 to this annex.
Annex 9C
Manufacturers are not required to implement software algorithms in the OBD system to individually track and report in-use performance data of monitors running continuously as defined in paragraph 4.2.3. of Annex 9B if these monitors are already part of one of the groups of monitors mentioned in Appendix 1 to this annex. In-use performance data of monitors associated to different exhaust lines or engine banks within a group of monitors shall be tracked and recorded separately as specified in paragraph 6. and reported as specified in paragraph 7.
Multiple monitors
For each group of monitors which are required to be reported by paragraph 4.1.1., the OBD system shall separately track in-use performance data, as specified in paragraph 6., for each of the specific monitors belonging to that group.
Limitation of the use of in-use performance data
In-use performance data of a single vehicle are used for the statistical evaluation of the in-use performance of the OBD system of a larger group of vehicles. Contrary to other OBD data, in-use performance data cannot be used to draw conclusions concerning the road-worthiness of an individual vehicle.
5.Requirements for calculating in-use performance ratios
Calculation of the in-use performance ratio
For each monitor m considered in the present annex, the in-use performance ratio is calculated with the following formula: IUPRm = Numeratorm / Denominatorm Where the Numeratorm and Denominatorm are incremented according to the specifications of this paragraph.
Requirements for the ratio when calculated and stored by system
Each IUPRm ratio shall have a minimum value of zero and a maximum value of 7.99527 with a resolution of 0.0001221. A ratio for a specific component shall be considered to be zero whenever the corresponding numerator is equal to zero and the corresponding denominator is not zero. A ratio for a specific component shall be considered to be the maximum value of 7.99527 if the corresponding denominator is zero or if the actual value of the numerator divided by the denominator exceeds the maximum value of 7.99527.
Requirements for incrementing the numerator
The numerator shall not be incremented more than once per driving cycle.
This value corresponds to a maximum hexadecimal value of 0xFFFF with a resolution of 0x1.
Annex 9C
The numerator for a specific monitor shall be incremented within 10 seconds if and only if the following criteria are satisfied on a single driving cycle:
(a) Every monitoring condition necessary for the monitor of the specific component to detect a malfunction and store a potential DTC has been satisfied, including enable criteria, presence or absence of related DTCs, sufficient length of monitoring time, and diagnostic executive priority assignments (e.g., diagnostic "A" shall execute prior to diagnostic "B"). Note: For the purpose of incrementing the numerator of a specific monitor, it may not be sufficient to satisfy all the monitoring conditions necessary for that monitor to determine the absence of a malfunction.
(b) For monitors that require multiple stages or events in a single driving cycle to detect a malfunction, every monitoring condition necessary for all events to have been completed shall be satisfied.
(c) For monitors which are used for failure identification and that run only after a potential DTC has been stored, the numerator and denominator may be the same as those of the monitor detecting the original malfunction.
(d) For monitors that require an intrusive operation to further investigate the presence of a malfunction, the manufacturer may submit to the Type Approval Authority an alternative way to increment the numerator. This alternative should be equivalent to that which would, had a malfunction been present, have permitted to increment the numerator. For monitors that run or complete during engine-off operation, the numerator shall be incremented within 10 seconds after the monitor has completed during engine-off operation or during the first 10 seconds of engine start on the subsequent driving cycle.
Requirements for incrementing the denominator
General incrementing rules
The denominator shall be incremented once per driving cycle, if during this driving cycle:
(a) The general denominator is incremented as specified in paragraph 5.4.; and
(b) The denominator is not disabled according to paragraph 5.6.; and
(c) When applicable, the specific additional incrementing rules specified in paragraph 5.3.2. are met.
Additional monitor specific incrementing rules
Specific denominator for evaporative system (reserved)
Specific denominator for secondary air systems (reserved)
Specific denominator for components / systems that operate at engine start-up only
Annex 9C
In addition to the requirements of paragraph 5.3.1. (a) and (b), the denominator(s) for monitors of components or systems that operate only at engine start-up shall be incremented if the component or strategy is commanded "on" for a time greater than or equal to 10 seconds. For purposes of determining this commanded "on" time, the OBD system may not include time during intrusive operation of any of the components or strategies later in the same driving cycle solely for the purposes of monitoring.
Specific denominator for components or systems that are not continuously commanded to function In addition to the requirements of paragraph 5.3.1. (a) and (b), the denominator(s) for monitors of components or systems that are not continuously commanded to function (e.g. Variable Valve Timing systems - VVT- or EGR valves), shall be incremented if that component or system is commanded to function (e.g., commanded "on", "open", "closed", "locked") on two or more occasions during the driving cycle, or for a cumulative time greater than or equal to 10 seconds, whichever occurs first.
Specific denominator for DPF
In addition to the requirements of paragraph 5.3.1. (a) and (b), in at least one driving cycle the denominator(s) for DPF shall be incremented if at least 800 cumulative kilometres of vehicle operation or alternatively at least 750 minutes of engine run time have been experienced since the last time the denominator was incremented.
Specific denominator for oxidation catalysts
In addition to the requirements of paragraph 5.3.1. (a) and (b), in at least one driving cycle the denominator(s) for monitors of oxidation catalyst used for the purpose of DPF active regeneration shall be incremented if a regeneration event is commanded for a time greater than or equal to 10 seconds.
Specific denominator for hybrids (reserved)
Requirements for incrementing the general denominator
The general denominator shall be incremented within 10 seconds, if and only if, all the following criteria are satisfied on a single driving cycle:
(a) Cumulative time since start of driving cycle is greater than or equal to 600 seconds while remaining:
(i) At an elevation of less than 2,500 meters above sea level; and
(ii) At an ambient temperature of greater than or equal to 266 K (-7 degrees Celsius); and
(iii) At an ambient temperature of lower than or equal to 308 K (35 degrees Celsius).
(b) Cumulative engine operation at or above 1,150 min-1 for greater than or equal to 300 seconds while under the conditions specified in the above subparagraph (a); as alternatives left to the manufacturer an engine operation at or above 15 per cent calculated load or a vehicle operation at or above 40 km/h may be used in lieu of the 1,150 min-1 criterion.
Annex 9C
(c) Continuous vehicle operation at idle (e.g., accelerator pedal released by driver and either vehicle speed less than or equal to 1.6 km/h or engine speed less than or equal to 200 min-1 above normal warmed-up
idle) for greater than or equal to 30 seconds while under the conditions specified in the above subparagraph (a).
Requirements for incrementing the ignition cycle counter
The ignition cycle counter shall be incremented once and only once per engine start.
Incrementing disablement of the numerators, of the denominators and of the general denominator
Within 10 seconds of a malfunction being detected (i.e. a potential or a confirmed and active DTC is stored), which disables a monitor, the OBD system shall disable further incrementing of the corresponding numerator and denominator for each monitor that is disabled. When the malfunction is no longer detected (e.g. the potential DTC is erased through self-clearing or through a scan-tool command), incrementing of all corresponding numerators and denominators shall resume within 10 seconds.
Within 10 seconds of the start of operation of a Power Take-Off unit (PTO) that disables a monitor as permitted in paragraph 5.2.5. of Annex 9B, the OBD system shall disable further incrementing of the corresponding numerator and denominator for each monitor that is disabled. When the PTO operation ends, incrementing of all corresponding numerators and denominators shall resume within 10 seconds.
In the case of a malfunction (i.e. a potential or confirmed and active DTC has been stored) preventing determination of whether the criteria for the Denominatorm of a monitor m mentioned in paragraph 5.3. are satisfied 2, the OBD system shall disable further incrementing the Numerator m and Denominatorm within 10 seconds. Incrementing the Numeratorm and Denominatorm shall resume within 10 seconds when the malfunction is no longer present (e.g., pending code erased through self-clearing or by a scan tool command).
In the case of a malfunction (i.e. a potential or confirmed and active DTC has been stored) preventing determination of whether the criteria for the General denominator mentioned in paragraph 5.4. are satisfied, the OBD system shall disable further incrementing the general denominator within 10 seconds. Incrementing the general denominator shall resume within 10 seconds when the malfunction is no longer present (e.g., pending code erased through self- clearing or by a scan tool command). The general denominator may not be disabled from incrementing for any other condition.
e.g. vehicle speed / engine speed / calculated load, ambient temperature, elevation, idle operation, or time of operation.
Annex 9C
6.Requirements for tracking and recording in-use performance data
For each group of monitors listed in Appendix 1 to this annex, the OBD system shall separately track numerators and denominators for each of the specific monitors listed in Appendix 3 to Annex 9B and belonging to that group. It shall report only the corresponding numerator and denominator for the specific monitor that has the lowest numerical ratio. If two or more specific monitors have identical ratios, the corresponding numerator and denominator for the specific monitor that has the highest denominator shall be reported for the specific group of monitors. In order to determine without bias the lowest ratio of a group, only the monitors specifically mentioned in that group shall be taken into consideration (e.g. a NOx sensor when used to perform one of the monitors listed in Annex 9B, Appendix 3, item 3 "SCR" will be taken into consideration into the "exhaust gas sensor" group of monitors and not in the "SCR" group of monitors) The OBD system shall also track and report the general denominator and the ignition cycle counter. Note: According to paragraph 4.1.1., manufacturers are not required to implement software algorithms in the OBD system to individually track and report numerators and denominators of monitors running continuously.
7.Requirements for storing and communicating in-use performance data
Communication of the in-use performance data is a new use-case and is not included in the three existing use-cases which are dedicated to the presence of possible malfunctions
Information about in-use performance data
The information about in-use performance data recorded by the OBD system shall be available upon off-board request according to paragraph 7.2. This information will provide type approval authorities with in-use performance data. The OBD system shall provide all information (according to the applicable standard set in Appendix 6 to Annex 9B) for the external IUPR test equipment to assimilate the data and provide an inspector with the following information:
(a) The VIN (vehicle identification number);
(b) The numerator and denominator for each group of monitors recorded by the system according to paragraph 6.;
(c) The general denominator;
(d) The value of the ignition cycle counter;
(e) The total engine running hours;
(f) Confirmed and active DTCs for Class A malfunctions;
(g) Confirmed and active DTCs for Class B (B1 and B2) malfunctions.
Annex 9C
This information shall be available through "read-only" access (i.e. no clearing).
Access to in-use performance data
Access to in-use performance data shall be provided only in accordance with the standards mentioned in Appendix 6 to Annex 9B and the following sub- paragraphs3. Access to the in-use performance data shall not be dependent on any access code or other device or method obtainable only from the manufacturer or its suppliers. Interpretation of the in-use performance data shall not require any unique decoding information, unless that information is publicly available. The access method (i.e. the access point/node) to in-use performance data shall be the same as the one used to retrieve all OBD information. This method shall permit access to the complete in-use performance data required by this annex.
Reinitialising in-use performance data
Reset to zero
Each number shall be reset to zero only when a Non-Volatile Random Access Memory (NVRAM) reset occurs (e.g., reprogramming event). Numbers may not be reset to zero under any other circumstances including when a scan tool command to clear fault codes is received.
Reset in case of memory overflow
If either the numerator or denominator for a specific monitor reaches 65,535 ± 2, both numbers shall be divided by two before either is incremented again to avoid overflow problems. If the ignition cycle counter reaches the maximum value of 65,535 ± 2, the ignition cycle counter may rollover and increment to zero on the next ignition cycle to avoid overflow problems. If the general denominator reaches the maximum value of 65,535 ± 2, the general denominator may rollover and increment to zero on the next driving cycle that meets the general denominator definition to avoid overflow problems.
The manufacturer is allowed to use an additional on-board diagnostic display, such as a dashboard mounted video display device, for providing access to in-use performance data. Such an additional device is not subject to the requirements of this annex.
Annex 9C – Appendix 1
Annex 9C - Appendix 1
Groups of monitors The groups of monitors considered in this annex are the following: A. Oxidation catalysts The monitors specific to that group are those listed in item 5 of Appendix 3 to Annex 9B. B. Selective Catalytical Reduction systems (SCR) The monitors specific to that group are those listed in item 3 of Appendix 3 to Annex 9B. C. Exhaust gas and oxygen sensors The monitors specific to that group are those listed in item 13 of Appendix 3 to Annex 9B. D. EGR systems and VVT The monitors specific to that group are those listed in items 6 and 9 and of Appendix 3 to Annex 9B. E. DPF systems The monitors specific to that group are those listed in item 2 of Appendix 3 to Annex 9B. F. Boost pressure control system The monitors specific to that group are those listed in item 8 of Appendix 3 to Annex 9B. G. NOx adsorber The monitors specific to that group are those listed in item 4 of Appendix 3 to Annex 9B. H. Three-way catalyst The monitors specific to that group are those listed in item 15 of Appendix 3 to Annex 9B. I. Evaporative systems (reserved) J. Secondary Air system (reserved) A specific monitor shall belong only to one of these groups.
Annex 10
Annex 10 — Requirements to limit Off-Cycle Emissions (OCE) and in-use
emissions
1.Applicability
This annex sets out the performance requirements and prohibition of defeat strategies for engines and vehicles type-approved according to this Regulation so as to achieve effective control of emissions under a broad range of engine and ambient operating conditions encountered during normal in-use vehicle operation. This annex also sets out the test procedures for testing off-cycle emissions during type approval and in actual use of the vehicle. This annex is based on the world-wide harmonized OCE, global technical regulation (gtr) No. 10.
2.Reserved1
3.Definitions
"Engine starting" means the process from the initiation of engine cranking until the engine reaches a speed 150 min-1 below the normal, warmed up idle speed (as determined in the drive position for vehicles equipped with an automatic transmission).
"Engine warm-up" means sufficient vehicle operation such that the coolant temperature reaches a minimum temperature of at least 70 °C.
"Rated speed" means the maximum full load speed allowed by the governor as specified by the manufacturer in his sales and service literature, or, if such a governor is not present, the speed at which the maximum power is obtained from the engine, as specified by the manufacturer in his sales and service literature.
"Regulated emissions" means "gaseous pollutants" and "particulate matter" (PM) as defined in paragraph 2. of this Regulation.
4.General requirements
Any engine system and any element of design liable to affect the emission of regulated pollutants shall be designed, constructed, assembled and installed so as to enable the engine and vehicle to comply with the provisions of this annex.
Prohibition of defeat strategies
Engine systems and vehicles shall not be equipped with a defeat strategy.
The numbering of this annex is consistent with the numbering of gtr No.10 on OCE. However, some paragraphs of the OCE gtr are not needed in this annex.
Reserved2
5.Performance requirements
Emission strategies
Emission strategies shall be designed so as to enable the engine system, in normal use, to comply with the provisions of this annex. Normal use is not restricted to the conditions of use as specified in paragraph 6.
Requirements for Base Emission Strategies (BES)
A BES shall not discriminate between operation on an applicable type approval or certification test and other operation and provide a lesser level of emission control under conditions not substantially included in the applicable type approval or certification tests.
Requirements for Auxiliary Emission Strategies (AES)
An AES shall not reduce the effectiveness of the emission control relative to a BES under conditions that may reasonably be expected to be encountered in normal vehicle operation and use, unless the AES satisfies one the following specific exceptions:
(a) Its operation is substantially included in the applicable type approval tests, including the off-cycle test procedures under paragraph 7. of this annex and the in-service provisions set out in paragraph 9. of this Regulation;
(b) It is activated for the purposes of protecting the engine and/or vehicle from damage or accident;
(c) It is only activated during engine starting or warm up as defined in this annex;
(d) Its operation is used to trade-off the control of one type of regulated emissions in order to maintain control of another type of regulated emissions under specific ambient or operating conditions not substantially included in the type approval or certification tests. The overall effect of such an AES shall be to compensate for the effects of extreme ambient conditions in a manner that provides acceptable control of all regulated emissions.
World-Harmonized Not-To-Exceed (WNTE) limits for gaseous and particulate exhaust emissions
Exhaust emissions shall not exceed the applicable emission limits specified in paragraph 5.2.2.
The applicable emission limits shall be the following:
(a) For CO: 2,000 mg/kWh;
(b) For THC: 220 mg/kWh;
(c) For NOx: 600 mg/kWh;
The numbering of this annex is consistent with the numbering of gtr No.10 on OCE. However, some paragraphs of the OCE gtr are not needed in this annex.
Annex 10
(d) For PM: 16 mg/kWh.
6.Ambient and operating conditions
The WNTE emission limits shall apply at:
(a) All atmospheric pressures greater than or equal to 82.5 kPa;
(b) All temperatures less than or equal to the temperature determined by equation 5 at the specified atmospheric pressure: T = -0.4514 x (101.3 – pb) + 311 (5) Where: T is the ambient air temperature, K pb is the atmospheric pressure, kPa
(c) All engine coolant temperature above 343 K (70 °C). The applicable ambient atmospheric pressure and temperature conditions are shown in Figure 1. WNTE Atmospheric Pressure and Temperature Range

7.Off-cycle laboratory testing and vehicle testing of engines at type approval
The off-cycle laboratory test requirements shall not apply for the type approval of positive ignition engine under this Regulation.
World-harmonized Not-To-Exceed control area
The WNTE control area consists of the engine speed and load points defined in paragraphs 7.1.1. through 7.1.6. Figure 2 is an example illustration of the WNTE control area.
Engine speed range
The WNTE control area shall include all operating speeds between the 30th percentile cumulative speed distribution over the WHTC test cycle, including idle, (n30) and the highest speed where 70 per cent of the maximum power occurs (nhi). Figure 3 is an example of the WNTE cumulative speed frequency distribution for a specific engine.
Engine torque range
The WNTE control area shall include all engine load points with a torque value greater than or equal to 30 per cent of the maximum torque value produced by the engine.
Engine power range
Notwithstanding the provisions of paragraphs 7.1.1. and 7.1.2., speed and load points below 30 per cent of the maximum power value produced by the engine shall be excluded from the WNTE control area for all emissions.
Application of engine family concept
In principal, any engine within a family with a unique torque/power curve will have its individual WNTE control area. For in-use testing, the individual WNTE control area of the respective engine shall apply. For type approval (certification) testing under the engine family concept of the WHDC gtr the manufacturer may optionally apply a single WNTE control area for the engine family under the following provisions:
(a) A single engine speed range of the WNTE control area may be used; if the measured engine speeds n30 and nhi are within ±3 per cent of the engine speeds as declared by the manufacturer. If the tolerance is exceeded for any of the engine speeds, the measured engine speeds shall be used for determining the WNTE control area;
(b) A single engine torque/power range of the WNTE control area may be used, if it covers the full range from the highest to the lowest rating of the family. Alternatively, grouping of engine ratings into different WNTE control areas is permitted.
Annex 10


Compliance exclusion from certain WNTE operating points
The manufacturer may request that the Type Approval Authority excludes operating points from the WNTE control area defined in paragraphs 7.1.1. through 7.1.4. during the certification/type approval. The Type Approval Authority may grant this exclusion if the manufacturer can demonstrate that the engine is never capable of operating at such points when used in any vehicle combination.
Minimum World-harmonized Not-To-Exceed event duration and data sampling frequency
To determine compliance with the WNTE emissions limits specified in paragraph 5.2., the engine shall be operated within the WNTE control area defined in paragraph 7.1. and its emissions shall be measured and integrated over a minimum period of 30 seconds. A WNTE event is defined as a single set of integrated emissions over the period of time. For example, if the engine operates for 65 consecutive seconds within the WNTE control area and ambient conditions this would constitute a single WNTE event and the emissions would be averaged over the full 65 second period. In the case of laboratory testing, the integrating period defined in paragraph 7.5. shall apply.
For engines equipped with emission controls that include periodic regeneration events, if a regeneration event occurs during the WNTE test, then the averaging period shall be at least as long as the time between the events multiplied by the number of full regeneration events within the sampling period. This requirement only applies for engines that send an electronic signal indicating the start of the regeneration event.
A WNTE event is a sequence of data collected at the frequency of at least
1 Hz during engine operation in the WNTE control area for the minimum event duration or longer. The measured emission data shall be averaged over the duration of each WNTE event.
In-use testing
A PEMS demonstration test shall be performed at type approval by testing the parent engine in a vehicle using the procedure described in Appendix 1 to this annex.
The manufacturer may select the vehicle that shall be used for testing but the vehicle choice shall be subject to the agreement of the Type Approval Authority. The characteristics of the vehicle used for the PEMS demonstration test shall be representative for the category of vehicle intended for the engine system. The vehicle may be a prototype vehicle.
At the request of the Type Approval Authority, an additional engine within the engine family or an equivalent engine representing a different vehicle category may be tested in a vehicle.
World-harmonized Not-To-Exceed laboratory testing
Where the provisions of this annex are used as the basis for laboratory testing the following provision shall apply:
Annex 10
The specific mass emissions of regulated pollutants shall be determined on the basis of randomly defined test points distributed across the WNTE control area. All the test points shall be contained within 3 randomly selected grid cells imposed over the control area. The grid shall comprise of 9 cells for engines with a rated speed less than 3,000 min-1 and 12 cells for engines with a rated speed greater than or equal to 3,000 min-1. The grids are defined as follows:
(a) The outer boundaries of the grid are aligned to the WNTE control area;
(b) 2 vertical lines spaced at equal distance between engine speeds n30 and nhi for 9 cell grids, or 3 vertical lines spaced at equal distance between engine speeds n30 and nhi for 12 cell grids; and
(c) 2 lines spaced at equal distance of engine torque (⅓) at each vertical line within the WNTE control area. Examples of the grids applied to specific engines are shown in Figures 5 and 6.
The 3 selected grid cells shall each include 5 random test points, so a total of 15 random points shall be tested within the WNTE control area. Each cell shall be tested sequentially; therefore all 5 points in one grid cell are tested before transiting to the next grid cell. The test points are combined into a single ramped steady state cycle.
The order in which each of the grid cells are tested, and the order of testing the points within the grid cell, shall be randomly determined. The 3 grid cells to be tested, the 15 test points, the order of testing the grid cells, and the order of the points within a grid cell shall be selected by the Type approval or Certification Authority using acknowledged statistical methods of randomization.
The average specific mass emissions of regulated gaseous pollutants shall not exceed the WNTE limit values specified in paragraph 5.2. when measured over any of the cycles in a grid cell with 5 test points.
The average specific mass emissions of regulated particulate pollutants shall not exceed the WNTE limit values specified in paragraph 5.2. when measured over the whole 15 test point cycle.
Laboratory test procedure
After completion of the WHSC cycle, the engine shall be preconditioned at mode 9 of the WHSC for a period of three minutes. The test sequence shall start immediately after completion of the preconditioning phase.
The engine shall be operated for 2 minutes at each random test point. This time includes the preceding ramp from the previous steady state point. The transitions between the test points shall be linear for engine speed and load and shall last 20 ± 1 seconds.
The total test time from start until finish shall be 30 minutes. The test of each set of 5 selected random points in a grid cell shall be 10 minutes, measured from the start of the entry ramp to the 1st point until the end of the steady state measurement at the 5th point. Figure 5 illustrates the sequence of the test procedure.
The WNTE laboratory test shall meet the validation statistics of paragraph 7.8.7. of Annex 4.
The measurement of the emissions shall be carried out in accordance with paragraphs 7.5., 7.7. and 7.8. of Annex 4.
The calculation of the test results shall be carried out in accordance with paragraph 8. of Annex 4.

Rounding
Each final test result shall be rounded in one step to the number of places to the right of the decimal point indicated by the applicable WHDC emission standard plus one additional significant figure, in accordance with ASTM E 29-06. No rounding of intermediate values leading to the final brake specific emission result is permitted.
8.Reserved
9.Reserved
10.Statement of off-cycle emission compliance
In the application for type approval, the manufacturer shall provide a statement that the engine family or vehicle complies with the requirements of this Regulation limiting off-cycle emissions. In addition to this statement, compliance with the applicable emission limits and in-use requirements shall be verified through additional tests.
Example statement of Off-Cycle Emission compliance
The following is an example compliance statement: "(Name of manufacturer) attests that the engines within this engine family comply with all requirements of this annex. (Name of manufacturer) makes this statement in good faith, after having performed an appropriate engineering evaluation of the emissions performance of the engines within the engine family over the applicable range of operating and ambient conditions."
Basis for Off-Cycle Emission compliance statement
The manufacturer shall maintain records at the manufacturer's facility which contain all test data, engineering analyses, and other information which provides the basis for the OCE compliance statement. The manufacturer shall provide such information to the Certification or Type Type Approval Authority upon request.
11.Documentation
The Type Approval Authority may decide to require that the manufacturer provides a documentation package. This should describe any element of design and emission control strategy of the engine system and the means by which it controls its output variables, whether that control is direct or indirect. The information may include a full description of the emission control strategy. In addition, this could include information on the operation of all AES and BES, including a description of the parameters that are modified by any AES and the boundary conditions under which the AES operate, and indication of which AES and BES are likely to be active under the conditions of the test procedures in this annex.
Annex 10 – Appendix 1
Annex 10 - Appendix 1 — PEMS demonstration test at type approval
A.1.1. Introduction This appendix describes the procedure for PEMS demonstration test at type approval. A.1.2. Test vehicle A.1.2.1. The vehicle used for demonstrating the PEMS demonstration test shall be representative for the vehicle category intended for the installation of the engine system. The vehicle may be a prototype vehicle or an adapted production vehicle. A.1.2.2. The availability and conformity of the ECU data-stream information shall be demonstrated (for example following the provision of paragraph 5 of Annex 8 to this Regulation). A.1.3. Test conditions A.1.3.1. Vehicle payload The vehicle payload shall be 50-60 per cent of the maximum vehicle payload in accordance with Annex 8. A.1.3.2. Ambient conditions The test shall be conducted under ambient conditions as described in paragraph 4.2. of Annex 8. A.1.3.3. The engine coolant temperature shall be in accordance with paragraph 4.3. of Annex 8. A.1.3.4. Fuel, lubricants and reagent The fuel, lubricating oil and reagent for the exhaust after-treatment system shall follow the provisions of paragraph 4.4. of Annex 8. A.1.3.5. Trip and operational requirements The trip and operational requirements shall be those described in paragraphs 4.5. to 4.6.8. of Annex 8. A.1.4. Emissions evaluation A.1.4.1. The test shall be conducted and the test results calculated in accordance with paragraph 6. of Annex 8. A.1.5. Report A.1.5.1. A technical report describing the PEMS demonstration test shall show the activities and results and give at least the following information:
(a) General information as described in paragraph 10.1.1. of Annex 8;
(b) Explanation as to why the vehicle(s) used for the test can be considered to be representative for the category of vehicles intended for the engine system;
(c) Information about test equipment and test data as described in paragraphs 10.1.3. and 10.1.4. of Annex 8;
(d) Information about the tested engine as described in paragraph 10.1.5. of Annex 8;
(e) Information about the vehicle used for the test as described in paragraph 10.1.6. of Annex 8;
(f) Information about the route characteristics as described in paragraph
of Annex 8;
(g) Information about instantaneous measured and calculated data as described in paragraphs 10.1.8. and 10.1.9. of Annex 8;
(h) Information about averaged and integrated data as described in paragraph 10.1.10. of Annex 8;
(i) Pass-fail results as described in paragraph 10.1.11. of Annex 8;
(j) Information about test verifications as described in paragraph 10.1.12. of Annex 8.
Annex 11
Annex 11 — Requirements to ensure the correct operation of NOx control
measures
1.Introduction
This annex sets out the requirements to ensure the correct operation of NO x control measures. It includes requirements for vehicles that rely on the use of a reagent in order to reduce emissions.
2.General requirements
Any engine system falling within the scope of this annex shall be designed, constructed and installed so as to be capable of meeting these requirements throughout the normal life of the engine under normal conditions of use. In achieving this objective it is acceptable that engines which have been used in excess of the appropriate durability period referred to in paragraph 5.4. of this Regulation may show some deterioration in performance and sensitivity of the monitoring system.
Alternative approval
Reserved1.
Required information
Information that fully describes the functional operational characteristics of an engine system covered by this annex shall be provided by the manufacturer in the form set out in Annex 1.
In its application for type approval, the manufacturer shall specify the characteristics of all reagents consumed by any emission control system. This specification shall include types and concentrations, operational temperature conditions, and references to international standards.
Detailed written information fully describing the functional operation characteristics of the driver warning system as provided in accordance with paragraph 4. and of the driver inducement system as provided in accordance with paragraph 5. shall be submitted to the Type Approval Authority at the time of application for the type approval.
When a manufacturer applies for an approval of an engine or engine family as a separate technical unit, it shall include in the documentation package referred to in paragraphs 3.1.3., 3.2.3. or 3.3.3. of this Regulation the appropriate requirements that will ensure that the vehicle, when used on the road or elsewhere as appropriate, will comply with the requirements of this annex. This documentation shall include the following:
This paragraph has been reserved for future alternative approvals (e.g. transposition of Euro VI into Regulation No. 83).
(a) The detailed technical requirements including the provisions ensuring the compatibility with the monitoring, warning, and inducement systems present in the engine system for the purpose of complying with the requirements of this annex;
(b) The verification procedure to be complied with for installation of the engine in the vehicle. The existence and the adequacy of such installation requirements may be checked during the approval process of the engine system. The documentation referred to in points (a) and (b) above shall not be required if the manufacturer applies for a type approval of a vehicle with regard to emissions.
Operating conditions
Any engine system falling within the scope of this annex shall retain its emission control function during all conditions regularly pertaining within the territory of the relevant region (e.g. European Union), especially at low ambient temperatures, in line with Annex 10.
The emission control monitoring system shall be operational:
(a) At ambient temperatures between 266 K and 308 K (-7 °C and 35 °C);
(b) At all altitudes below 1,600 m;
(c) At engine coolant temperatures above 343 K (70 °C). This paragraph shall not apply in the case of monitoring for reagent level in the storage tank, where monitoring shall be conducted under all conditions where measurement is technically feasible including all conditions when a liquid reagent is not frozen.
Reagent freeze protection
The manufacturer may use a heated or a non-heated reagent tank and dosing system, in accordance with the general requirements of paragraph 2.3.1. A heated system shall meet the requirements of paragraph 2.4.2. A non heated system shall meet the requirements of paragraph 2.4.3.
The use of a non-heated reagent tank and dosing system shall be indicated in written instructions to the owner of the vehicle.
Heated reagent tank and dosing system
If the reagent has frozen, the manufacturer shall ensure that reagent is available for use within a maximum of 70 minutes after the start of the vehicle at 266 K (- 7 °C) ambient temperature.
Demonstration
The reagent tank and dosing system shall be soaked at 255 K (-18 °C) for 72 hours or until the bulk of the reagent becomes solid.
After the soak period provided in paragraph 2.4.2.2.1. the engine shall be started and operated at 266 K (- 7 °C) ambient temperature as follows: 10 to 20 minutes idling, followed by up to 50 minutes at no more than 40 per cent load.
Annex 11
The reagent dosing system shall be fully functional at the end of the test procedures described in paragraphs 2.4.2.2.1. and 2.4.2.2.2.
Demonstration of compliance with the requirements of paragraph 2.4.2.2. may be done in a cold chamber test cell equipped with an engine or vehicle dynamometer or may be based on vehicle field tests, as approved by the Type Approval Authority.
Non-heated reagent tank and dosing system
The driver warning system described in paragraph 4. shall be activated if no reagent dosing occurs at an ambient temperature ≤ 266 K (-7 °C).
The severe inducement system described in paragraph 5.4. shall be activated if no reagent dosing occurs at an ambient temperature ≤ 266 K (-7 °C) within a maximum of 70 minutes after vehicle start.
Each separate reagent tank installed on a vehicle shall include a means for taking a sample of any fluid inside the tank and for doing so without the need for information not stored on-board the vehicle. The sampling point shall be easily accessible without the use of any specialised tool or device. Keys or systems which are normally carried on the vehicle for locking access to the tank shall not be considered to be specialised tools or devices for the purpose of this paragraph.
3.Maintenance requirements
The manufacturer shall furnish or cause to be furnished to all owners of new vehicles or new engines type-approved in accordance with this Regulation written instructions about the emission control system and its correct operation. Those instructions shall state that if the vehicle emission control system is not functioning correctly the driver will be informed of a problem by the driver warning system, and that operation of the driver inducement system as a consequence of ignoring this warning will result in the vehicle being unable to efficiently conduct its mission.
The instructions shall indicate requirements for the proper use and maintenance of vehicles in order to maintain their emissions performance, including, where relevant, the proper use of consumable reagents.
The instructions shall be written in clear and non-technical language and in the official language or languages of the Member State in which a new vehicle or engine is sold or registered.
The instructions shall specify if consumable reagents have to be refilled by the vehicle operator between normal maintenance intervals. The instructions shall also specify the required reagent quality. They shall indicate how the operator should refill the reagent tank. The information shall also indicate a likely rate of reagent consumption for the type of vehicle and how often it is likely to need to be replenished.
The instructions shall specify that use of, and refilling with, a required reagent of the correct specifications is essential in order for the vehicle to comply with the requirements for the issuing of the certificate of conformity for that vehicle type.
The instructions shall state that it may be a criminal offence to use a vehicle that does not consume any reagent if the reagent is required for the reduction of emissions.
The instructions shall explain how the warning system and driver inducement systems work. In addition, the consequences, in terms of vehicle performance and fault logging, of ignoring the warning system and not replenishing the reagent or rectifying a problem shall be explained.
4.Driver warning system
The vehicle shall include a driver warning system using visual alarms that informs the driver when a low reagent level, incorrect reagent quality, too low a rate of reagent consumption, or a malfunction, has been detected that may be due to tampering and that will lead to operation of the driver inducement system if not rectified in a timely manner. The warning system shall also be active when the driver inducement system described in paragraph 5. has been activated.
The vehicle On-Board Diagnostics (OBD) display system described in Annex 9B shall not be used for the purpose of providing the visual alarms described in paragraph 4.1. The warning shall not be the same as the warning used for the purposes of OBD (that is, the MI – malfunction indicator) or other engine maintenance. It shall not be possible to turn off the warning system or visual alarms by means of a scan-tool if the cause of the warning activation has not been rectified. Conditions for activation and deactivation of the warning system and visual alarms are described in Appendix 2 to this annex.
The driver warning system may display short messages, including messages indicating clearly the following:
(a) The remaining distance or time before activation of the low-level or severe inducements;
(b) The level of torque reduction;
(c) The conditions under which vehicle disablement can be cleared. The system used for displaying the messages referred to in this point may be the same as the one used for OBD or other maintenance purposes.
At the choice of the manufacturer, the warning system may include an audible component to alert the driver. The cancelling of audible warnings by the driver is permitted.
The driver warning system shall be activated as specified in paragraphs 6.2., 7.2., 8.4., and 9.3.
The driver warning system shall be deactivated when the conditions for its activation have ceased to exist. The driver warning system shall not be automatically deactivated without the reason for its activation having been remedied.
The warning system may be temporarily interrupted by other warning signals providing important safety-related messages.
Annex 11
A facility to permit the driver to dim the visual alarms provided by the warning system may be provided on vehicles for use by the rescue services or on vehicles designed and constructed for use by the armed services, civil defence, fire services and forces responsible for maintaining public order.
Details of the driver warning system activation and deactivation procedures are specified in Appendix 2 to this annex.
As part of the application for type approval under this Regulation, the manufacturer shall demonstrate the operation of the driver warning system, as specified in Appendix 1 to this annex.
5.Driver inducement system
The vehicle shall incorporate a two-stage driver inducement system starting with a low-level inducement (a performance restriction) followed by a severe inducement (effective disablement of vehicle operation).
The requirement for a driver inducement system shall not apply to engines or vehicles for use by the rescue services or to engines or on vehicles designed and constructed for use by the armed services, civil defence, fire services and forces responsible for maintaining public order. Permanent deactivation of the driver inducement system shall only be done by the engine or vehicle manufacturer.
Low-level inducement system
The low-level inducement system shall reduce the maximum available engine torque across the engine speed range by 25 per cent between the peak torque speed and the governor breakpoint as described in Appendix 3 to this annex. The maximum available reduced engine torque below the peak torque speed of the engine before imposition of the torque reduction shall not exceed the reduced torque at that speed. The low-level inducement system shall be activated when the vehicle becomes stationary for the first time after the conditions specified in paragraphs 6.3., 7.3., 8.5. and 9.4., have occurred.
Severe inducement system
The vehicle or engine manufacturer shall incorporate at least one of the severe inducement systems described in paragraphs 5.4.1. to 5.4.3. and the "disable on time limit" system described in paragraph 5.4.4.
A "disable after restart" system shall limit the vehicle speed to 20 km/h ("creep mode") after the engine has been shut down at the request of the driver ("key-off").
A "disable after fuelling" system shall limit the vehicle speed to 20 km/h ("creep mode") after the fuel tank level has risen a measurable amount, which shall not be more than 10 per cent of the fuel tank capacity and shall be approved by the Type Approval Authority based on the technical capabilities of the fuel level meter and a declaration by the manufacturer.
A "disable after parking" system shall limit the vehicle speed to 20 km/h ("creep mode") after the vehicle has been stationary for more than one hour.
A "disable on time limit" system shall limit the vehicle speed to 20 km/h ("creep mode") on the first occasion when the vehicle becomes stationary after eight hours of engine operation if none of the systems described in paragraphs 5.4.1. to 5.4.3. has been previously been activated.
The driver inducement system shall be enabled as specified in paragraphs 6.3., 7.3., 8.5., and 9.4.
When the driver inducement system has determined that the severe inducement system shall be activated, the low-level inducement system shall remain activated until the vehicle speed has been limited to 20 km/h ("creep mode").
The driver inducement system shall be deactivated when the conditions for its activation have ceased to exist. The driver inducement system shall not be automatically deactivated without the reason for its activation having been remedied.
Details of the driver inducement system activation and deactivation procedures are described in Appendix 2 to this annex.
As part of the application for type approval under this Regulation, the manufacturer shall demonstrate the operation of the driver inducement system, as specified in Appendix 1 to this annex.
6.Reagent availability
Reagent indicator
The vehicle shall include a specific indicator on the dashboard that clearly informs the driver of the level of reagent in the reagent storage tank. The minimum acceptable performance level for the reagent indicator is that it shall continuously indicate the reagent level whilst the driver warning system referred to in paragraph 4. is activated to indicate problems with reagent availability. The reagent indicator may be in the form of an analogue or digital display, and may show the level as a proportion of the full tank capacity, the amount of remaining reagent, or the estimated driving distance remaining. The reagent indicator shall be placed in close proximity to the fuel level indicator.
Activation of the driver warning system
The driver warning system specified in paragraph 4. shall be activated when the level of reagent is less than 10 per cent of the capacity of the reagent tank or a higher percentage at the choice of the manufacturer.
The warning provided shall be sufficiently clear for the driver to understand that the reagent level is low. When the warning system includes a message display system, the visual warning shall display a message indicating a low level of reagent. (for example, "urea level low", "AdBlue level low", or "reagent low").
The driver warning system does not initially need to be continuously activated, however activation shall escalate in intensity so that it becomes continuous when the level of the reagent is approaching a very low proportion of the capacity of the reagent tank and the point where the driver
Annex 11
inducement system will come into effect is approached. It shall culminate in a driver notification at a level that is at the choice of the manufacturer, but is sufficiently more noticeable than the point where the driver inducement system in paragraph 6.3. comes into effect.
The continuous warning shall not be easily disabled or ignored. When the warning system includes a message display system, an explicit message shall be displayed (for example. "fill up urea", "fill up AdBlue", or "fill up reagent"). The continuous warning may be temporarily interrupted by other warning signals providing important safety related messages.
It shall not be possible to turn off the driver warning system until the reagent has been replenished to a level not requiring its activation.
Activation of the driver inducement system
The low-level inducement system described in paragraph 5.3. shall be enabled, and subsequently activated according to the requirements of that section, if the reagent tank level goes below 2.5 per cent of its nominally full capacity or a higher percentage at the choice of the manufacturer.
The severe inducement system described in paragraph 5.4. shall be enabled, and subsequently activated according to the requirements of that section, if the reagent tank is empty (that is, the dosing system is unable to draw further reagent from the tank) or at any level below 2.5 per cent of its nominally full capacity at the discretion of the manufacturer.
It shall not be possible to turn off the low-level or severe driver inducement system until the reagent has been replenished to a level not requiring their respective activation.
7.Reagent quality monitoring
The vehicle shall include a means of determining the presence of an incorrect reagent on board a vehicle.
The manufacturer shall specify a minimum acceptable reagent concentration
CDmin, which results in tailpipe emissions not exceeding the limit values specified in paragraph 5.3. of this Regulation.
During the phase-in period specified in paragraph 4.10.7. of this Regulation and upon request of the manufacturer for the purpose of paragraph 7.1.1. the reference to the NOx emission limit specified in paragraph 5.3. to this Regulation shall be replaced by the value of 900 mg/kWh.
The correct value of CDmin shall be demonstrated during type approval by the procedure defined in Appendix 6 to this annex and recorded in the extended documentation package as specified in paragraph 5.1.4. to this Regulation.
Any reagent concentration lower than CD min shall be detected and be regarded, for the purpose of paragraph 7.1., as being incorrect reagent.
A specific counter ("the reagent quality counter") shall be attributed to the reagent quality. The reagent quality counter shall count the number of engine operating hours with an incorrect reagent.
Details of the reagent quality counter activation and deactivation criteria and mechanisms are described in Appendix 2 to this annex.
The reagent quality counter information shall be made available in a standardised manner in accordance with the provisions of Appendix 5 to this annex.
Activation of the driver warning system
When the monitoring systems detects or, as appropriate, confirms that the reagent quality is incorrect, the driver warning system described in paragraph 4. shall be activated. When the warning system includes a message display system, it shall display a message indicating the reason for the warning (for example: "incorrect urea detected", "incorrect AdBlue detected", or "incorrect reagent detected").
Activation of the driver inducement system
The low-level inducement system described in paragraph 5.3. shall be enabled, and subsequently activated according to the requirements of that section, if the reagent quality is not rectified within 10 engine operating hours after the activation of the driver warning system described in paragraph 7.2.
The severe inducement system described in paragraph 5.4. shall be enabled, and subsequently activated according to the requirements of that section, if the reagent quality is not rectified within 20 engine operating hours after the activation of the driver warning system described in paragraph 7.2.
The number of hours prior to activation of the inducement systems shall be reduced in case of a repetitive occurrence of the malfunction, in accordance with the mechanism described in Appendix 2 to this annex.
8.Reagent consumption monitoring
The vehicle shall include a means of determining reagent consumption and providing off-board access to consumption information.
Reagent consumption and dosing activity counters
A specific counter shall be attributed to the reagent consumption (the "reagent consumption counter") and another to the dosing activity (the "dosing activity counter"). These counters shall count the number of engine operating hours which occur with an incorrect reagent consumption and, respectively, an interruption of the reagent dosing activity.
Details of the reagent consumption counter and dosing counter activation and deactivation criteria and mechanisms are described in Appendix 2 to this annex.
The reagent consumption counter and the dosing counter information shall be made available in a standardised manner according to the provisions of Appendix 5 to this annex.
Monitoring conditions
The maximum detection period for insufficient reagent consumption is 48 hours or the period equivalent to a demanded reagent consumption of at least 15 litres, whichever is longer.
In order to monitor reagent consumption, at least one of the following parameters within the vehicle or engine shall be monitored:
(a) The level of reagent in the on-vehicle storage tank;
Annex 11
(b) The flow of reagent or quantity of reagent injected at a position as close as technically possible to the point of injection into an exhaust after-treatment system.
Activation of the driver warning system
The driver warning system described in paragraph 4. shall be activated if a deviation of more than 20 per cent between the average reagent consumption and the average demanded reagent consumption by the engine system over a period to be defined by the manufacturer, which shall not be longer than the maximum period defined in paragraph 8.3.1., is detected. When the warning system includes a message display system, it shall display a message indicating the reason for the warning (for example: "urea dosing malfunction", "AdBlue dosing malfunction", or "reagent dosing malfunction").
Until the end of the phase-in period specified in paragraph 4.10.7. of this Regulation the driver warning system described in paragraph 4. shall be activated if a deviation of more than 50 per cent between the average reagent consumption and the average demanded reagent consumption by the engine system over the period to be defined by the manufacturer, which shall not be longer than the maximum period defined in paragraph 8.3.1. is detected.
The driver warning system described in paragraph 4. shall be activated in the case of interruption in reagent dosing. When the warning system includes a message display system, it shall display a message indicating an appropriate warning. This activation shall not be required where the interruption is demanded by the engine ECU because the vehicle operating conditions are such that the vehicle’s emission performance does not require reagent dosing.
Activation of the driver inducement system
The low-level inducement system described in paragraph 5.3. shall be enabled, and subsequently activated according to the requirements of that section, if an error in the reagent consumption or an interruption in reagent dosing is not rectified within 10 engine operating hours after the activation of the driver warning system specified in paragraphs 8.4.1. and 8.4.2.
The severe inducement system described in paragraph 5.4. shall be enabled, and subsequently activated according to the requirements of that section, if an error in the reagent consumption or an interruption in reagent dosing is not rectified within 20 engine operating hours after the activation of the driver warning system in paragraphs 8.4.1. and 8.4.2.
The number of hours prior to activation of the inducement systems shall be reduced in case of a repetitive occurrence of the malfunction in accordance with the mechanism described in Appendix 2 to this annex.
9.Monitoring failures that may be attributed to tampering
In addition to the level of reagent in the reagent tank, the reagent quality, and the reagent consumption, the following failures shall be monitored by the anti-tampering system because they may be attributed to tampering:
(a) Impeding of the EGR valve operation;
(b) Failures of the anti-tampering monitoring system, as described in paragraph 9.2.1.
Monitoring requirements
The anti-tampering monitoring system shall be monitored for electrical failures and for removal or deactivation of any sensor that prevents it from diagnosing any other failures mentioned in paragraphs 6. to 8. (component monitoring). A non-exhaustive list of sensors that affect the diagnostic capability are those directly measuring NOx concentration, urea quality sensors, ambient sensors, and sensors used for monitoring reagent dosing activity, reagent level, or reagent consumption.
EGR valve counter
A specific counter shall be attributed to an impeded EGR valve. The EGR valve counter shall count the number of engine operating hours when any DTC associated with an impeded EGR valve is confirmed to be active.
Details of the EGR valve counter activation and deactivation criteria and mechanisms are described in Appendix 2 to this annex.
The EGR valve counter information shall be made available in a standardised manner in accordance with the provisions of Appendix 5 to this annex.
Monitoring system counters
A specific counter shall be attributed to each of the monitoring failures considered in point (b) of paragraph 9.1. The monitoring system counters shall count the number of engine operating hours when the DTC associated with a malfunction of the monitoring system is confirmed to be active. Grouping of several faults into a single counter is permitted.
Details of the criteria for activation and deactivation of the monitoring system counters and the associated mechanisms are described in Appendix 2 to this annex.
The monitoring system counter information shall be made available in a standardised manner in accordance with the provisions of Appendix 5 to this annex.
Activation of the driver warning system
The driver warning system described in paragraph 4. shall be activated in the case where any of the failures specified in paragraph 9.1. occurs, and shall indicate that an urgent repair is required. When the warning system includes a message display system, it shall display a message indicating either the reason for the warning (for example, "reagent dosing valve disconnected", or "critical emission failure").
Activation of the driver inducement system
The low-level inducement system described in paragraph 5.3. shall be enabled, and subsequently activated according to the requirements of that section, if a failure specified in paragraph 9.1. is not rectified within 36 engine operating hours after the activation of the driver warning system in paragraph 9.3.
Annex 11
The severe inducement system described in paragraph 5.4. shall be enabled, and subsequently activated according to the requirements of that section, if a failure specified in paragraph 9.1. is not rectified within 100 engine operating hours after the activation of the driver warning system in paragraph 9.3.
The number of hours prior to activation of the inducement systems shall be reduced in case of a repetitive occurrence of the malfunction in accordance with the mechanism described in Appendix 2 to this annex.
Annex 11 - Appendix 1 — Demonstration requirements
A.1.1. General A.1.1.1 The manufacturer shall submit to the Type Approval Authority a complete documentation package justifying the compliance of the SCR system with the requirements of this annex as regards its capabilities for monitoring and activation of the driver warning and inducement system, which may include:
(a) Algorithms and decision charts;
(b) Tests and/or simulation results;
(c) Reference to previously approved monitoring systems, etc. A.1.1.2. Compliance with the requirements of this annex shall be demonstrated during type approval by performing, as illustrated in Table 1 and specified in this Appendix, the following demonstrations:
(a) A demonstration of the warning system activation;
(b) A demonstration of the low level inducement system activation;
(c) A demonstration of the severe inducement system activation.
Illustration of the content of the demonstration process in accordance with the provisions in
paragraphs A.1.3., A.1.4. and A.1.5.
Demonstration elements
Warning system activation
(a) 4 activation tests (incl. lack of reagent)
specified in
(b) Supplementary demonstration elements, as appropriate
paragraph A.1.3.
Low-level inducement (a) 2 activation tests (incl. lack of reagent)
activation specified in
(b) Supplementary demonstration elements
paragraph A.1.4.
(c ) 1 torque reduction test
Severe inducement (a) 2 activation tests (incl. lack of reagent)
activation specified in
(b) Supplementary demonstration elements, as appropriate
paragraph A.1.5.
(c) Demonstration elements of correct vehicle behavior
during inducement
Annex 11 – Appendix 1
A.1.2. Engine families or OBD engine families
The compliance of an engine family or an OBD engine family with the
requirements of this annex may be demonstrated by testing one of the members
of the family under consideration, provided that the manufacturer demonstrates
to the Type Approval Authority that the monitoring systems necessary for
complying with the requirements of this annex are similar within the family.
A.1.2.1. This demonstration may be performed by presenting to the approval
authorities such elements as algorithms, functional analyses, etc.
A.1.2.2. The test engine is selected by the manufacturer in agreement with the Type
Approval Authority. It may or may not be the parent engine of the considered
family.
A.1.2.3. In the case where engines of an engine family belong to an OBD engine
family that has already been type-approved, the compliance of that engine
family is deemed to be demonstrated without further testing (Figure 1),
provided the manufacturer demonstrates to the authority that the monitoring
systems necessary for complying with the requirements of this annex are
similar within the engine and OBD engine families under consideration.of Appendix 2 or, as appropriate, until either the reagent tank is
empty or, has reached the level below 2.5 per cent of nominal full capacity of the tank at which the manufacturer has chosen to activate the severe inducement system. A.1.5.4.5. If the manufacturer has opted for the "disable after restart" approach referred to in paragraph 5.4.1. of this annex, the vehicle shall be operated until the end of the current operating sequence, which must include a demonstration that the vehicle is capable of exceeding 20 km/h. After restart, the vehicle speed shall be limited to no more than 20 km/h. A.1.5.4.6. If the manufacturer has opted for the "disable after fuelling" approach referred to in paragraph 5.4.2. of this annex, the vehicle shall be operated for a short distance, chosen by the manufacturer, after it has been brought to a state where there is sufficient spare capacity in the tank to permit it to be refuelled with the amount of fuel defined in paragraph 5.4.2. of this annex. The vehicle operation before refuelling shall include a demonstration that the vehicle is capable of exceeding 20 km/h. After re-fuelling the vehicle with the amount of fuel defined in paragraph 5.4.2. of this annex, the vehicle speed shall be limited to no more than 20 km/h. A.1.5.4.7. If the manufacturer has opted for the "disable after parking" approach referred to in paragraph 5.4.3. of this annex, the vehicle shall be stopped after having been run for a short distance, chosen by the manufacturer, which is sufficient to demonstrate that the vehicle is capable of exceeding a speed of 20 km/h. After the vehicle has been stationary for more than one hour, the vehicle speed shall be limited to no more than 20 km/h. Annex 11 – Appendix 2
Annex 11 - Appendix 2 — Description of the driver warning and inducement activation
and deactivation mechanisms A.2.1. To complement the requirements specified in this annex concerning the driver warning and inducement activation and deactivation mechanisms, this Appendix specifies the technical requirements for an implementation of those activation and deactivation mechanisms consistent with the OBD provisions of Annex 9B. All definitions used in Annex 9B are applicable to this appendix. A.2.2. Activation and deactivation mechanisms of the driver warning system A.2.2.1. The driver warning system shall be activated when the diagnostic trouble code (DTC) associated with a malfunction justifying its activation has the status defined in Table 1.
Activation of the driver warning system
Failure type DTC status for activation of the warning
system
Poor reagent quality Confirmed and active
Low reagent Potential (if detected after
consumption 10 hours), potential or confirmed
and active otherwise
Absence of dosing Confirmed and active
Impeded EGR valve Confirmed and active
Malfunction of the Confirmed and active
monitoring system
A.2.2.1.1. If the counter associated with the relevant failure is not at zero, and is
consequently indicating that the monitor has detected a situation where the
malfunction may have occurred for a second or subsequent time, the driver
warning system shall be activated when the DTC has the status "potential".
A.2.2.2. The driver warning system shall be deactivated when the diagnostic system
concludes that the malfunction relevant to that warning is no longer present
or when the information, including DTCs relative to the failures, justifying its
activation is erased by a scan tool.
A.2.2.2.1. Erasing of failure information by means of a scan tool
A.2.2.2.1.1. Erasing of information, including DTCs relative to failures justifying the
activation of a driver warning signal and of their associated data, by means of
a scan tool shall be performed in accordance with Annex 9B.
A.2.2.2.1.2. The erasing of failure information shall only be possible under "engine-off"
conditions.
A.2.2.2.1.3. When failure information, including DTCs, is erased, any counter associated
with these failures and which is specified in this annex as one that must not
be erased shall not be erased.
A.2.3. Activation and deactivation mechanism of the driver inducement system
A.2.3.1. The driver inducement system shall be activated when the warning system is
active and the counter relevant to the type of malfunction justifying its
activation has reached the value specified in Table 2.
A.2.3.2. The driver inducement system shall be deactivated when the system no
longer detects a malfunction justifying its activation, or if the information,
including the DTCs, relative to the failures justifying its activation has been
erased by a scan tool or maintenance tool.
A.2.3.3. The driver warning and inducement systems shall be immediately activated
or deactivated as appropriate in accordance with the provisions of
paragraph 6. of this annex after assessment of the reagent quantity in the
reagent tank. In that case, the activation or deactivation mechanisms shall not
depend upon the status of any associated DTC.
A.2.4. Counter mechanism
A.2.4.1. General
A.2.4.1.1. To comply with the requirements of this annex, the system shall contain at
least 5 counters to record the number of hours during which the engine has
been operated while the system has detected any of the following:
(a) An incorrect reagent quality;
(b) An incorrect reagent consumption;
(c) An interruption of reagent dosing activity;
(d) An impeded EGR valve;
(e) A failure of the monitoring system as defined of paragraph 9.1. (b) of
this annex.
A.2.4.1.2. Each of these counters shall count up to the maximum value provided in a
2 byte counter with 1 hour resolution, and shall hold that value unless the
conditions allowing the counter to be reset to zero are met.
A.2.4.1.3. A manufacturer may use a single or multiple monitoring system counters.
A single counter may accumulate the number of hours of 2 or more different
malfunctions relevant to that type of counter.
A.2.4.1.3.1. When the manufacturer decides to use multiple monitoring system counters,
the system shall be capable of assigning a specific monitoring system counter
to each malfunction that is relevant, in accordance with this annex, to that
type of counter.
A.2.4.2. Principle of counter mechanisms
A.2.4.2.1. Each of the counters shall operate as follows:
A.2.4.2.1.1. If starting from zero, the counter shall begin counting as soon as a
malfunction relevant to that counter is detected and the corresponding
diagnostic trouble code (DTC) has the status described in Table 1.
Annex 11 – Appendix 2
A.2.4.2.1.2. The counter shall halt and hold its current value if a single monitoring event
occurs and the malfunction that originally activated the counter is no longer
detected or if the failure has been erased by a scan tool or a maintenance tool.
A.2.4.2.1.2.1. If the counter stops counting when the severe inducement system is active,
the counter shall be kept frozen at the value defined in Table 2.
A.2.4.2.1.2.2. In the case of a single monitoring system counter, that counter shall continue
counting if a malfunction relevant to that counter has been detected and its
corresponding Diagnostic trouble code (DTC) has the status "confirmed and
active". It shall halt and hold the value specified in paragraph A.2.4.2.1.2., or
A.2.4.2.1.2.1. as appropriate, if no malfunction that would justify the counter
activation is detected or if all the failures relevant to that counter have been
erased by a scan tool or a maintenance tool.Counters and inducement
Frozen value held by the
Counter value for counter during the period
DTC status for first low-level Counter value for just after severe
activation of the counter inducement severe inducement inducement
Reagent Confirmed and 10 hours 20 hours 18 hours
quality counter active
Reagent Potential or 10 hours 20 hours 18 hours
consumption confirmed and active
counter (see Table 1)
Dosing counter Confirmed and 10 hours 20 hours 18 hours
active
EGR valve Confirmed and 36 hours 100 hours 95 hours
counter active
Monitoring Confirmed and 36 hours 100 hours 95 hours
system counter active
A.2.4.2.1.3. Once frozen, the counter shall be reset to zero when the monitors relevant to
that counter have run at least once to completion of their monitoring cycle
without having detected a malfunction and no malfunction relevant to that
counter has been detected during 36 engine operating hours since the counter
was last held (see Figure 1).
A.2.4.2.1.4. The counter shall continue counting from the point at which it had been held
if a malfunction relevant to that counter is detected during a period when the
counter is frozen (see Figure 1).Annex 11 - Appendix 3 — Low level inducement torque reduction scheme
This diagram illustrates the provisions of paragraph 5.3. of this annex on torque reduction.
Torque
75% Peak Torque 25% Reduction 75% Maximum Torque at Governor Break Point
Speed Peak Governor Torque Break Point
Annex 11 – Appendix 4
Annex 11 - Appendix 4 — Demonstration of correct installation on a vehicle in the case
of engines type-approved as a separate technical unit This appendix applies when the vehicle manufacturer requests type approval of a vehicle with an approved engine with regard to emissions in accordance with this Regulation. In this case, and in addition to the installation requirements of paragraph 6. of this Regulation, a demonstration of the correct installation is required. This demonstration shall be performed by the presentation to the Type Approval Authority of a technical case using evidence such as engineering drawings, functional analyses, and the results of previous tests. Where appropriate, and if the manufacturer chooses, the evidence presented may include installations of systems or components on real or simulated vehicles, provided that the manufacturer can present evidence that the presented installation properly represents the standard that will be achieved in production. The demonstration shall address the conformity of the following elements to the requirements of this annex:
(a) The installation on board the vehicle as regards its compatibility with the engine- system (hardware, software and communication);
(b) The warning and inducement systems (for example, pictograms, activation schemes, etc.);
(c) The reagent tank and the elements (for example, sensors) mounted on the vehicle for the purpose of complying with this annex. Correct activation of the warning and inducement systems, and of the information storage and on-board and off-board communication systems, may be checked. No check of these systems shall require the dismounting of the engine system or components, nor shall it generate unnecessary testing burden by requiring processes such as changing of the urea quality or running of the vehicle or engine for long periods of time. In order to minimise the burden upon the vehicle manufacturer, electric disconnections and simulation of counters with high operating hours shall be selected as checks on these systems if possible.
Annex 11 - Appendix 5 — Access to "NOx control information"
A.5.1. This appendix describes the specifications permitting access to information required in order to check the status of the vehicle with regard to the correct operation of the NO x control system ("NO x control information"). A.5.2. Access methods A.5.2.1. The "NOx control information" shall be provided only in accordance with the standard or standards used in association with the retrieval of engine system information from the OBD system. A.5.2.2. Access to the "NOx control information" shall not be dependent on any access code or other device or method obtainable only from the manufacturer or the manufacturer’s suppliers. Interpretation of that information shall not require any specialised or unique decoding information, unless that information is publicly available. A.5.2.3. It shall be possible to retrieve all "NOx control information" from the system using the access method that is used to retrieve OBD information in accordance with Annex 9A. A.5.2.4. It shall be possible to retrieve all "NOx control information" from the system using the test equipment that is used to retrieve OBD information in accordance with Annex 9A. A.5.2.5. The "NOx control information" shall be available through "read-only" access (that is, it shall not be possible to clear, reset, erase, or modify any of the data). A.5.3. Information content A.5.3.1. The "NOx control information" shall contain at least the following information:
(a) The VIN (vehicle identification number);
(b) The status of the warning system (active; non-active);
(c) The status of the low-level inducement system (active; enabled; non- active);
(d) The status of the severe inducement system (active; enabled; non- active);
(e) Number of warm-up cycles and number of engine operating hours since recorded "NOx control information" was cleared due to service or repair;
Annex 11 – Appendix 5
(f) The types of the counters relevant to this annex (reagent quality, reagent consumption, dosing system, EGR valve, monitoring system) and the number of engine operating hours indicated by each of the these counters; in the case of multiple counters being used, the value to be considered for the purposes of the "NO x control information" is the value of each of the counters relative to the failure under consideration having the highest value;
(g) The DTCs associated with the malfunctions relevant to this annex and their status ("potential", "confirmed and active", etc.).
Annex 11 - Appendix 6 — Demonstration of the minimum acceptable reagent
concentration CDmin A.6.1. The manufacturer shall demonstrate the correct value of CD min during type approval by performing the hot part of the WHTC cycle, in accordance with the provisions of Annex 4, using a reagent with the concentration CD min. A.6.2. The test shall follow the appropriate pre-conditioning cycle, permitting a closed loop NOx control system to perform adaptation to the quality of the reagent with the concentration CDmin. A.6.3. The pollutant emissions resulting from this test shall be lower than the emission limits specified in paragraphs 7.1.1. and 7.1.1.1. of this annex.
Annex 12
Annex 12 — CO2 emissions and fuel consumption
1.Introduction
This annex sets out the provisions and test procedures for reporting CO 2 emissions and fuel consumption.
2.General requirements
CO2 emissions and fuel consumption shall be determined over the WHTC and WHSC test cycles in accordance with paragraphs 7.2. to 7.8. of Annex 4.
The test results shall be reported as cycle averaged brake specific values and expressed in the unit of g/kWh.
3.Determination of CO2 emissions
Raw measurement
This paragraph shall apply, if CO2 is measured in the raw exhaust gas.
Measurement
CO2 in the raw exhaust gas emitted by the engine submitted for testing shall be measured with a non-dispersive infrared (NDIR) analyser in accordance with paragraph 9.3.2.3. and Appendix 2 to Annex 4. The measurement system shall meet the linearity requirements of paragraph 9.2. and
of Annex 4.
The measurement system shall meet the requirements of paragraphs 9.3.1., 9.3.4. and 9.3.5. of Annex 4.
Data evaluation
The relevant data shall be recorded and stored in accordance with paragraph 7.6.6. of Annex 4. The traces of the recorded concentrations and the trace of the exhaust gas mass flow rate shall be time aligned with the transformation time as defined in paragraph 3.1. of Annex 4.
Calculation of cycle averaged emission
If measured on a dry basis, the dry/wet correction according to paragraph 8.1. of Annex 4 shall be applied to the instantaneous concentration values before any further calculation is done. The mass of CO2 (g/test) shall be determined by calculating the instantaneous mass emissions from the raw CO2 concentration and the exhaust gas mass flow, aligned with respect to their transformation times as determined in accordance with paragraph 8.4.2.2. of Annex 4, integrating the instantaneous values over the cycle, and multiplying the integrated value with the u values of CO2 from Table 5 of Annex 4. The following equation shall be applied: i n mCO2 = u i 1 CO2 cCO2,i q mew,i f (in g/test)
Where: uCO2 is the ratio between CO2 density and density of the exhaust gas cCO2,i is the instantaneous CO2 concentration in the exhaust gas, ppm qmew,i is the instantaneous exhaust mass flow, kg/s f is the data sampling rate, Hz n is the number of measurements Optionally, the CO2 mass may be calculated in accordance with paragraph 8.4.2.4. of Annex 4 by using a CO2 molar mass (MCO2) of 44.01 g/mol.
Dilute measurement
This paragraph applies, if CO2 is measured in the dilute exhaust gas.
Measurement
CO2 in the dilute exhaust gas emitted by the engine submitted for testing shall be measured with a non-dispersive infrared (NDIR) analyser in accordance with paragraph 9.3.2.3. and Appendix 2 to Annex 4. Dilution of the exhaust shall be done with filtered ambient air, synthetic air or nitrogen. The flow capacity of the full flow system shall be large enough to completely eliminate water condensation in the dilution and sampling systems. The measurement system shall meet the linearity requirements of paragraph 9.2. and The measurement system shall meet the requirements of paragraphs 9.3.1., 9.3.4. and 9.3.5. of Annex 4.
Data evaluation
The relevant data shall be recorded and stored in accordance with paragraph 7.6.6. of Annex 4.
Calculation of cycle averaged emission
If measured on a dry basis, the dry/wet correction according to paragraph 8.1. of Annex 4 shall be applied. For systems with constant mass flow (with heat exchanger), the mass of CO 2 (g/test) shall be determined with the following equation: mCO2 = 0.001519 x cCO2 x med (in g/test) Where: cCO2 is the average background corrected CO2 concentration, ppm 0.001519 is the ratio between CO2 density and density of air (u factor) med is the total diluted exhaust mass over the cycle, kg For systems with flow compensation (without heat exchanger), the mass of CO2 (g/test) shall be determined by calculating the instantaneous mass emissions and integrating the instantaneous values over the cycle. Also, the background correction shall be applied directly to the instantaneous concentration values. The following equation shall be applied:
m cCO2,e 0.001519 med cCO2,d 1 1/D 0.001519 n mCO2 = ed,i i 1
Annex 12
Where: cCO2,e is the CO2 concentration measured in the diluted exhaust gas, ppm cCO2,d is the CO2 concentration measured in the dilution air, ppm 0.001519 is the ratio between CO2 density and density of air (u factor) med,i is the instantaneous mass of the diluted exhaust gas, kg med is the total mass of diluted exhaust gas over the cycle, kg D is the dilution factor Optionally, the u factor may be calculated with equation 57 in paragraph 8.5.2.3.1. of Annex 4 by using a CO2 molar mass (MCO2) of 44.01 g/mol. CO2 background correction shall be applied in accordance with paragraph 8.5.2.3.2. of Annex 4.
Calculation of brake specific emissions
The cycle work needed for the calculation of brake specific CO2 emissions shall be determined in accordance with paragraph 7.8.6. of Annex 4.
WHTC
The brake specific emissions eCO2 (g/kWh) shall be calculated as follows:
0.14 m 0.86 m eCO2 CO2,cold CO2,hot
0.14 W act, cold 0.86 W act, hot Where: mCO2, cold is the CO2 mass emissions of the cold start test, g/test mCO2, hot is the CO2 mass emissions of the hot start test, g/test Wact, cold is the actual cycle work of the cold start test, kWh Wact, hot is the actual cycle work of the hot start test, kWh
WHSC
The brake specific emissions eCO2 (g/kWh) shall be calculated as follows:
mCO2 eCO2 Wact Where: mCO2 is the CO2 mass emissions, g/test Wact is the actual cycle work, kWh
4.Determination of fuel consumption
Measurement
Measurement of the instantaneous fuel flow shall be done by systems that preferably measure mass directly such as the following:
(a) Mass flow sensor;
(b) Fuel weighing;
(c) Coriolis meter. The fuel flow measurement system shall have the following:
(a) An accuracy of ±2 per cent of the reading or ±0.3 per cent of full scale whichever is better;
(b) A precision of ±1 per cent of full scale or better;
(c) A rise time that does not exceed 5 s. The fuel flow measurement system shall meet the linearity requirements of paragraph 9.2. and Table 7 of Annex 4. Precautions shall be taken to avoid measurement errors. Such precautions shall at least include the following:
(a) The careful installation of the device according to the instrument manufacturers" recommendations and to good engineering practice;
(b) Flow conditioning as needed to prevent wakes, eddies, circulating flows, or flow pulsations that affect accuracy or precision of the fuel flow system;
(c) Account for any fuel that bypasses the engine or returns from the engine to the fuel storage tank.
Data evaluation
The relevant data shall be recorded and stored in accordance with paragraph 7.6.6. of Annex 4.
Calculation of cycle averaged fuel consumption
The mass of fuel (g/test) shall be determined by the sum of the instantaneous values over the cycle, as follows: i n qmf = q i 1 mf, i f 1000
Where: qmf,i is the instantaneous fuel flow, kg/s f is the data sampling rate, Hz n is the number of measurements
Calculation of brake specific fuel consumption
The cycle work needed for the calculation of the brake specific fuel consumption shall be determined in accordance with paragraph 7.8.6. of Annex 4.
WHTC
The brake specific fuel consumption ef (g/kWh) shall be calculated as follows:
0.14 q 0.86 q ef mf, cold mf, hot
0.14 Wact, cold 0.86 Wact, hot
Annex 12
Where: qmf, cold is the fuel mass of the cold start test, g/test qmf, hot is the fuel mass of the hot start test, g/test Wact, cold is the actual cycle work of the cold start test, kWh Wact, hot is the actual cycle work of the hot start test, kWh
WHSC
The brake specific fuel consumption ef (g/kWh) shall be calculated as follows:
qmf ef Wact Where: qmf is the fuel mass, g/test Wact is the actual cycle work, kWh
Annex 12 - Appendix 1
Provisions on CO2 emissions and fuel consumption for extension of a type approval for a vehicle type-approved under this Regulation with a reference mass exceeding 2,380 kg but not exceeding 2,610 kg A.1.1. Introduction A.1.1.1. This appendix sets out the provisions and test procedures for reporting CO 2 emissions and fuel consumption for extension of type approval for a vehicle type-approved under this Regulation to a vehicle with a reference mass exceeding 2,380 kg but not exceeding 2,610 kg. A.1.2. General requirements A.1.2.1. In order to receive an extension of a type approval for a vehicle in respect of its engine type-approved under this Regulation to a vehicle with a reference mass exceeding 2,380 kg but not exceeding 2,610 kg the manufacturer shall meet the requirements of Regulation No.101 with the exceptions specified below. A.1.2.1.2. Paragraph 5.2.4. of Regulation No.101 shall be understood as follows:
(1) Density: measured on the test fuel according to ISO 3675 or an equivalent method. For petrol, diesel, ethanol (E85) and ethanol for dedicated C.I. engines (ED95) the density measured at 288 K (15 °C) will be used; for LPG and natural gas/biomethane a reference density shall be used, as follows: 0.538 kg/litre for LPG; 0.654 kg/m3 for NG.
(2) Hydrogen-carbon-oxygen ratio: fixed values shall be used which are: C1H1.93O0.032 for petrol (E10); C1H1.86O0.006 for diesel (B7); C1H2.525 for LPG (liquefied petroleum gas); CH4 for NG (natural gas) and biomethane; C1H2.74O0.385 for ethanol (E85); C1H2.92O0.46 for ethanol for dedicated C.I. engines (ED95). A.1.2.1.3. Paragraph 1.4.3. of Annex 6. of Regulation No. 101 shall be understood as: "1.4.3. The fuel consumption, expressed in litres per 100 km (in the case of petrol, LPG, ethanol (E85 and ED95) and diesel) or in m3 per 100 km (in the case of NG/biomethane) is calculated by means of the following formulae:
(a) For vehicles with a positive ignition engine fuelled with petrol (E10): FC = (0.120/D) ∙ [(0.831 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO 2)]
Annex 12 – Appendix 1
(b) For vehicles with a positive ignition engine fuelled with LPG: FCnorm = (0.1212/0.538) ∙ [(0.825 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO2)] If the composition of the fuel used for the test differs from the composition that is assumed for the calculation of the normalised consumption, on the manufacturer’s request a correction factor cf may be applied, as follows: FCnorm = (0.1212/0.538) ∙ (cf) ∙ [(0.825 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO2)] The correction factor cf, which may be applied, is determined as follows: cf = 0.825 + 0.0693 nactual Where: nactual is the actual H/C ratio of the fuel used
(c) For vehicles with a positive ignition engine fuelled with NG/biomethane: FCnorm = (0.1336/0.654) ∙ [(0.749 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO2)]
(d) For vehicles with a positive ignition engine fuelled with ethanol (E85): FC = (0.1742/D) ∙ [(0.574 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO 2)]
(e) For vehicles with a compression ignition engine fuelled with diesel (B7): FC = (0.1165/D) ∙ [(0.859 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO 2)]
(f) For vehicles with a dedicated compression ignition engine fuelled with ethanol (ED95) FC = (0.186/D) ∙ [(0.538 ∙ HC) + (0.429 ∙ CO) + (0.273 ∙ CO 2)] In these formulae: FC is the fuel consumption in litre per 100 km (in the case of petrol, ethanol, LPG, diesel or biodiesel) or in m3 per 100 km (in the case of natural gas) HC is the measured emission of hydrocarbons in g/km CO is the measured emission of carbon monoxide in g/km CO2 is the measured emission of carbon dioxide in g/km D is the density of the test fuel. In the case of gaseous fuels this is the density at 288 K (15 °C).
Annex 13
Annex 13
Type approval of replacement pollution control devices as separate technical unit
1.Introduction
This annex contains additional requirements for the type approval of replacement pollution control devices as separate technical units.
Definition
"Type of pollution control device" means catalytic converters and particulate filters which do not differ in any of the following essential aspects:
(a) Number of substrates, structure and material;
(b) Type of activity of each substrate;
(c) Volume, ratio of frontal area and substrate length;
(d) Catalyst material content;
(e) Catalyst material ratio;
(f) Cell density;
(g) Dimensions and shape;
(h) Thermal protection.
2.General requirements
Marking
Each replacement pollution control device shall bear at least the following identifications:
(a) The manufacturer’s name or trade mark;
(b) The make and identifying part number of the replacement pollution control device as recorded in the information document issued in accordance with the model set out in Appendix 1 to this annex.
Each original replacement pollution control device shall bear at least the following identifications:
(a) The vehicle or engine manufacturer’s name or trade mark;
(b) The make and identifying part number of the original replacement pollution control device as recorded in the information referred to in paragraph 2.3.
Documentation
Each replacement pollution control device shall be accompanied by the following information:
(a) The manufacturer’s name or trade mark;
Annex 13
(b) The make and identifying part number of the replacement pollution control device as recorded in the information document issued in accordance with the model set out in Appendix 1 to this annex;
(c) The vehicles or engines including year of manufacture for which the replacement pollution control device is approved, including, where applicable, a marking to identify if the replacement pollution control device is suitable for fitting to a vehicle that is equipped with an on- board diagnostic (OBD) system;
(d) Installation instructions. The information referred to in this point shall be available in the product catalogue distributed to points of sale by the manufacturer of replacement pollution control devices.
Each original replacement pollution control device shall be accompanied by the following information:
(a) The vehicle or engine manufacturer’s name or trade mark;
(b) The make and identifying part number of the original replacement pollution control device as recorded in the information mentioned in paragraph 2.3.;
(c) The vehicles or engines for which the original replacement pollution control device is of a type covered by paragraph 3.2.12.2.1. of Part 1 of Annex 1, including, where applicable, a marking to identify if the original replacement pollution control device is suitable for fitting to a vehicle that is equipped with an on-board diagnostic (OBD) system;
(d) Installation instructions. This information referred to in this point shall be available in the product catalogue distributed to points of sale by the vehicle or engine manufacturer.
For an original replacement pollution control device, the vehicle or engine manufacturer shall provide to the Type Approval Authority the necessary information in electronic format which makes the link between the relevant part numbers and the type approval documentation. This information shall contain the following:
(a) Make(s) and type(s) of vehicle or engine;
(b) Make(s) and type(s) of original replacement pollution control device;
(c) Part number(s) of original replacement pollution control device;
(d) Type approval number of the relevant engine or vehicle type(s).
3.Separate technical unit type approval mark
Every replacement pollution control device conforming to the type approved under this Regulation as a separate technical unit shall bear a type approval mark.
The type approval mark referred to in paragraph 3.1. shall consist of:
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted the type approval (see paragraph 4.12.3.1. of this Regulation);
The number of this Regulation, followed by the letter "R", a dash and the approval number to the right of the circle prescribed in paragraph 3.2.1.;
The letters "RD" after the national symbol, the purpose of which is to distinguish that the type approval has been granted for a replacement pollution control device.
The type approval mark shall be affixed to the replacement pollution control device in such a way as to be clearly legible and indelible. It shall, wherever possible, be visible when the replacement pollution control device is installed on the vehicle.
An example of the type approval mark for a separate technical unit is given in Appendix 3 to this annex.
Notice of approval or of extension or of refusal of approval or production definitively discontinued of a replacement pollution control device pursuant to this Regulation shall be communicated to the Parties to the 1958 Agreement which apply this Regulation, by means of a form conforming to the model in Appendix 2 to this annex. Values measured during the type test shall also be shown.
4.Technical requirements
General requirements
The replacement pollution control device shall be designed, constructed and capable of being mounted so as to enable the engine and vehicle to comply with the rules with which it was originally in compliance and that pollutant emissions are effectively limited throughout the normal life of the vehicle under normal conditions of use.
The installation of the replacement pollution control device shall be at the exact position of the original equipment pollution control device, and the position on the exhaust line of the exhaust gas, temperature and pressure sensors shall not be modified.
If the original equipment pollution control device includes thermal protections, the replacement pollution control device shall include equivalent protections.
Upon request of the applicant for the type approval of the replacement component, the Type Approval Authority that granted the original type approval of the engine system shall make available on a non-discriminatory basis, the information referred to in paragraphs 3.2.12.2.6.8.1.1. and 3.2.12.2.6.8.2.1. in Part 1 of the information document contained in Annex 1 for each engine to be tested.
Annex 13
General durability requirements
The replacement pollution control device shall be durable, that is designed, constructed and capable of being mounted so that reasonable resistance to the corrosion and oxidation phenomena to which it is exposed is obtained, having regard to the conditions of use of the vehicle. The design of the replacement pollution control device shall be such that the elements active in controlling emissions are adequately protected from mechanical shock so as to ensure that pollutant emissions are effectively limited throughout the normal life of the vehicle under normal conditions of use. The applicant for type approval shall provide to the Type Approval Authority details of the test used to establish robustness to mechanical shock and the results of that test.
Requirements regarding emissions
Outline of procedure for evaluation of emissions
The engines indicated in paragraph 3.4.4. (a) of this Regulation equipped with a complete emissions control system including the replacement pollution control device of the type for which approval is requested, shall be subjected to tests appropriate for the intended application as described in Annex 4, in order to compare its performance with the original emissions control system according to the procedure described below.
Where the replacement pollution control device does not comprise the complete emissions control system, only new original equipment or new original replacement pollution control components shall be used to provide a complete system.
The emissions control system shall be aged according to the procedure described in paragraph 4.3.2.4. and retested to establish the durability of its emissions performance. The durability of a replacement pollution control device is determined from a comparison of the 2 successive sets of exhaust gas emissions tests.
(a) The first set is that made with the replacement pollution control device which has been run in with 12 WHSC cycles;
(b) The second set is that made with the replacement pollution control device which has been aged by the procedures detailed below. Where approval is applied for different types of engines from the same engine manufacturer, and provided that these different types of engines are fitted with an identical original equipment pollution control system, the testing may be limited to at least two engines selected after agreement with the Type Approval Authority.
Procedure for evaluation of emissions performance of a replacement pollution control device
The engine or engines shall be fitted with a new original equipment pollution control device according to paragraph 4.11.4. of this Regulation.
The exhaust after-treatment system shall be preconditioned with 12 WHSC cycles. After this preconditioning, the engines shall be tested according to the WHDC test procedures specified in Annex 4. Three exhaust gas tests of each appropriate type shall be performed. The test engines with the original exhaust after-treatment system or original replacement exhaust after-treatment system shall comply with the limit values according to the type approval of the engine or vehicle.
Exhaust gas test with replacement pollution control device
The replacement pollution control device to be evaluated shall be fitted to the exhaust after-treatment system tested according to the requirements of paragraph 4.3.2.1., replacing the relevant original equipment exhaust after- treatment device. The exhaust after-treatment system incorporating the replacement pollution control device shall then be preconditioned with 12 WHSC cycles. After this preconditioning, the engines shall be tested according to the WHDC procedures described in Annex 4. Three exhaust gas tests of each appropriate type shall be performed.
Initial evaluation of the emission of pollutants of engines equipped with replacement pollution control devices. The requirements regarding emissions of the engines equipped with the replacement pollution control device shall be deemed to be fulfilled if the results for each regulated pollutant (CO, HC, NMHC, methane, NOx, NH3, particulate mass and particle number as appropriate for the type approval of the engine) meet the following conditions:
(1) M ≤ 0.85S + 0.4G
(2) M≤G Where: M: mean value of the emissions of one pollutant obtained from the three tests with the replacement pollution control device; S: mean value of the emissions of one pollutant obtained from the three tests with the original or original replacement pollution control device; G: limit value of the emissions of one pollutant according to the type approval of the vehicle.
Durability of emissions performance
The exhaust after-treatment system tested in paragraph 4.3.2.2. and incorporating the replacement pollution control device shall be subjected to the durability procedures described in Appendix 4 to this annex.
Exhaust gas test with aged replacement pollution control device
The aged exhaust after-treatment system incorporating the aged replacement control device shall then be fitted to the test engine used in paragraphs 4.3.2.1. and 4.3.2.2.
Annex 13
The aged exhaust after-treatment systems shall be preconditioned with 12 WHSC cycles and subsequently tested using the WHDC procedures described in Annex 4. Three exhaust gas tests of each appropriate type shall be performed.
Determination of ageing factor for the replacement pollution control device
The ageing factor for each pollutant shall be the ratio of the applied emission values at the useful life end point and at the start of the service accumulation. (e.g. if the emissions of pollutant A at the useful life end point are 1.50 g/kWh and those at the start of the service accumulation are 1.82 g/kWh, the ageing factor is 1.82/1.50 = 1.21).
Evaluation of the emission of pollutants of engines equipped with replacement pollution control devices The requirements regarding emissions of the engines equipped with the aged replacement pollution control device (as described in paragraph 4.3.2.5.) shall be deemed to be fulfilled if the results for each regulated pollutant (CO, HC, NMHC, methane, NOx, NH3, particulate mass and particle number as appropriate for the type approval of the engine) meet the following condition: M*AF ≤ G Where: M: mean value of the emissions of one pollutant obtained from the three tests with the preconditioned replacement pollution control device before ageing (i.e. results from paragraph 4.3.2.); AF: the ageing factor for one pollutant; G: limit value of the emissions of one pollutant according to the type approval of the vehicle(s).
Replacement pollution control device technology family
The manufacturer may identify a replacement pollution control device technology family, to be identified by basic characteristics which shall be common to devices within the family. To belong to the same replacement pollution control device technology family the replacement pollution control devices shall have the following:
(a) The same emissions control mechanism (oxidation catalyst, three-way catalyst, particulate filter, selective catalytic reduction for NOx etc.);
(b) The same substrate material (same type of ceramic, or same type of metal);
(c) The same substrate type and cell density;
(d) The same catalytically active materials and, where more than one, the same ratio of catalytically active materials;
(e) The same total charge of catalytically active materials;
(f) The same type of washcoat applied by the same process.
Assessment of the durability of emissions performance of a replacement pollution control device by use of a technology family ageing factor. Where the manufacturer has identified a replacement pollution control technology family, the procedures described in paragraph 4.3.2. may be used to determine the ageing factors for each pollutant for the parent of that family. The engine on which these tests are conducted shall have a minimum engine displacement of 0.75 dm³ per cylinder.
Determination of durability performance of family members
A replacement pollution control device A within a family and intended to be mounted on an engine of displacement CA may be considered to have the same ageing factors as the parent replacement pollution control device P, determined on an engine of displacement CP, if the following conditions are fulfilled: VA/CA ≥ VP/CP Where: VA: Substrate volume (in dm³) of replacement pollution control device A VP: Substrate volume (in dm³) of the parent replacement pollution control device P of the same family and both engines use the same method for regeneration of any emissions control devices incorporated in the original exhaust after-treatment system. This requirement shall apply only where devices requiring regeneration are incorporated in the original exhaust after-treatment system. If these conditions are fulfilled, the emissions durability performance of other members of the family may be determined from the emissions results (S) of that family member determined according to the requirements set out in paragraphs 4.3.2.1., 4.3.2.2. and 4.3.2.3. and using the ageing factors determined for the parent of that family.
Requirements regarding exhaust back-pressure
The back pressure shall not cause the complete exhaust system to exceed the value specified according to paragraph 6.1.2. of this Regulation.
Requirements regarding OBD compatibility (applicable only to replacement pollution control devices intended to be fitted to vehicles equipped with an OBD system)
OBD compatibility demonstration is required only when the original pollution control device was monitored in the original configuration.
The compatibility of the replacement pollution control device with the OBD system shall be demonstrated by using the procedures described in Annex 9B for replacement pollution control devices intended to be fitted to engines or vehicles type-approved in accordance with this Regulation.
The provisions in this Regulation applicable to components other than pollution control devices shall not apply.
Annex 13
The replacement pollution control device manufacturer may use the same preconditioning and test procedure as used during the original type approval. In this case, the Type Approval Authority which granted original type approval of an engine of a vehicle shall provide, on request and on a non- discriminatory basis, appendix on test conditions to Annex 1 which contains the number and type of preconditioning cycles and the type of test cycle used by the original equipment manufacturer for OBD testing of the pollution control device.
In order to verify the correct installation and functioning of all other components monitored by the OBD system, the OBD system shall indicate no malfunction and have no stored fault codes prior to the installation of any of the replacement pollution control device. An evaluation of the status of the OBD system at the end of the tests described in paragraphs 4.3.2. to 4.3.2.7. may be used for this purpose.
The malfunction indicator shall not activate during vehicle operation required by paragraphs 4.3.2. to 4.3.2.7.
5.Conformity of production
Measures to ensure the conformity of production shall be taken in accordance with paragraph 8. of this Regulation.
Special provisions
The checks referred to in Appendix 2 to the 1958 Agreement (E/ECE/324//E/ECE/TRANS/505/Rev.2) shall include compliance with the characteristics as defined under "type of pollution control device" in paragraph 1.2.1.
For the application of paragraph 8. of this Regulation, the tests described in paragraph 4.3. of this annex (requirements regarding emissions) may be carried out. In this case, the holder of the approval may request, as an alternative, to use as a basis for comparison not the original equipment pollution control device, but the replacement pollution control device which was used during the type approval tests (or another sample that has been proven to conform to the approved type). Emissions values measured with the sample under verification shall then on average not exceed by more than 15 per cent the mean values measured with the sample used for reference.
Annex 13 - Appendix 1 — Model information document
Information document No … relating to the type approval of replacement pollution control devices The following information shall be supplied in triplicate and include a list of contents. Any drawings shall be supplied in appropriate scale and sufficient detail on size A4 or on a folder of A4 format. Photographs, if any, shall show sufficient detail. If the systems, components or separate technical units have electronic controls, information concerning their performance shall be supplied.
0.General
In the case of components and separate technical units, location and method
0.9 Name and address of the manufacturer’s authorised representative (if any): ...
1.Description of the device
Type of the replacement pollution control device: (oxidation catalyst, three-
Drawings of the replacement pollution control device, identifying in particular all the characteristics referred to under "type of pollution control
Description of the engine and vehicle type or types for which the replacement
Number(s) and/or symbol(s) characterising the original pollution control device(s) which the replacement pollution control device is intended to
Annex 13 – Appendix 1
Is the replacement pollution control device intended to be compatible with OBD requirements? (Yes/No)1
Is the replacement pollution control device compatible with existing vehicle/engine control systems? (Yes/No)1
Description and drawings showing the position of the replacement pollution
Delete where not applicable
Annex 13 - Appendix 2 — Communication concerning the approval of a replacement
pollution control device pursuant to Regulation No. 49, 06 series of amendments (Maximum format: A4 (210 x 297 mm)) issued by: Name of administration:
Concerning2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued
of a replacement pollution control device as a type of component/separate technical unit (1) pursuant to Regulation No. 49, 06 series of amendments Reason for Extension ……………………
Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation) Strike out what does not apply.
Annex 13 – Appendix 2
Section I
Means of identification of type marked on the component/separate technical
In the case of components and separate technical units, location and method
Section II
1.Additional information
Make and type of the replacement pollution control device: (oxidation catalyst, three-way catalyst, SCR catalyst, particulate filter etc.):
Engine and vehicle type(s) for which the pollution control device type:
Type(s) of engine on which the replacement pollution control device has been
Has the replacement pollution control device demonstrated compatibility with OBD requirements (Yes/No)4
Technical Service responsible for carrying out the tests:
__________________ If the means of identification of type contains characters not relevant to describe the vehicle, component or separate technical unit types covered by this type approval certificate such characters shall be represented in the document by the symbol:"?" (e.g. ABC??123??). Delete where not applicable
Attachments: Information package. Test report.
Annex 13 – Appendix 3
Annex 13 - Appendix 3 — Arrangement of approval mark
This appendix provides details on the arrangement of the approval mark issued and affixed to a replacement pollution control device in conformity with paragraph 3. of this annex The following schematic presents the general lay-out, proportions and contents of the marking. The meaning of numbers and alphabetical character are identified, and sources to determine the corresponding alternatives for each approval case are also referred.
Number of country1 Letter denoting a replacement granting the approval pollution control device
a 3 RD a a E5 a 3 49 R – 062439 a a = 8 mm (minimum) Approval number Number of Regulation (Regulation No. 49) Series of amendments
Number of country according to footnote in paragraph 4.12.3.1. of this Regulation.
Annex 13 - Appendix 4 — Ageing procedure for evaluation of durability
This appendix set out the procedures for ageing a replacement pollution control device for the purpose of evaluating the durability.
For demonstrating the durability the replacement pollution control device shall be subject to the requirements set out in paragraphs 1. to 3.4.2. of Annex 7.
For the purpose of demonstrating durability of the replacement pollution control device the minimum service accumulation periods as set out in
may be used.
Minimum service accumulation period Category of vehicle in which engine will be installed Minimum service accumulation period Category N1 vehicles Category N2 vehicles Category N3 vehicles with a maximum technically permissible mass not exceeding 16 tonnes Category N3 vehicles with a maximum technically permissible mass exceeding 16 tonnes Category M1 vehicles Category M2 vehicles Category M3 vehicles of classes I, II, A and B, with a maximum technically permissible mass not exceeding 7.5 tonnes Category M3 vehicles of classes III and B with a maximum technically permissible mass exceeding 7.5 tonnes Annex 14
Annex 14 — Access to vehicle OBD information
1.Access to OBD information
Applications for type approval or amendment of a type approval shall be accompanied by the relevant information concerning the engine or vehicle OBD system. This relevant information shall enable manufacturers of replacement or retrofit components to make the parts they manufacture compatible with the vehicle OBD system with a view to fault-free operation assuring the vehicle user against malfunctions. Similarly, such relevant information shall enable the manufacturers of diagnostic tools and test equipment to make tools and equipment that provide for effective and accurate diagnosis of engine or vehicle emission control systems.
Upon request, the Type Approval Authorities shall make paragraph 2.1. of this annex containing the relevant information on the OBD system available to any interested components, diagnostic tools or test equipment manufacturer on a non-discriminatory basis.
If an Type Approval Authority receives a request from any interested components, diagnostic tools or test equipment manufacturer for information on the OBD system of an engine system or vehicle that has been type- approved to a previous version of this Regulation:
- The Type Approval Authority shall, within 30 days, request the manufacturer of the vehicle in question to make available the information required in paragraph 2.1. of this annex;
- The manufacturer shall submit this information to the Type Approval Authority within two months of the request;
- The Type Approval Authority shall transmit this information to the Type Approval Authoritiesof the Contracting Parties and the Type Approval Authority which granted the original type approval shall attach this information to Annex 1 to this Regulation and concerning the approval information of engine system or vehicle type.
This requirement shall not invalidate any approval previously granted pursuant to this Regulation nor prevent extensions to such approvals under the terms of the Regulation under which they were originally granted.
Information can only be requested for replacement or service components that are subject to UN type approval, or for components that form part of a system that is subject to UN type approval.
The request for information shall identify the exact specification of the engine system or vehicle model for which the information is required. It shall confirm that the information is required for the development of replacement or retrofit parts or components or diagnostic tools or test equipment.
2.OBD data
The following additional information shall be provided by the engine or vehicle manufacturer for the purposes of enabling the manufacture of OBD- compatible replacement or service parts and diagnostic tools and test equipment, unless such information is covered by intellectual property rights or constitutes specific know-how of the manufacturer or the OEM supplier(s).
A description of the type and number of the pre-conditioning cycles used for the original type approval of the engine or vehicle.
A description of the type of the OBD demonstration cycle used for the original type approval of the engine or vehicle for the component monitored by the OBD system.
A comprehensive document describing all sensed components with the strategy for fault detection and MI activation (fixed number of driving cycles or statistical method), including a list of relevant secondary sensed parameters for each component monitored by the OBD system and a list of all OBD output codes and format used (with an explanation of each code and format) associated with individual emission-related power-train components and individual non-emission related components, where monitoring of the component is used to determine MI activation. In particular, in the case of vehicle types that use a communication link in accordance with ISO 15765-4 "Road vehicles — Diagnostics on Controller Area Network (CAN) - Part 4: Requirements for emissions-related systems", a comprehensive explanation for the data given in service $ 05 Test ID $ 21 to FF and the data given in service $ 06, and a comprehensive explanation for the data given in service $06 Test ID $ 00 to FF, for each OBD monitor ID supported, shall be provided. In case other communication protocols standards are used, equivalent comprehensive explanation shall be provided.
The information required by this paragraph may, for example, be defined by completing a table as follows:
Monitoring Fault detection MI activation Component Fault code strategy criteria criteria Secondary parameters Preconditioning Demonstration test nd SCR catalyst P20EE NOx sensor 1 Difference 2 cycle Engine speed, One OBD test OBD test cycle and 2 signals between engine load, cycle (WHTC, (WHTC, hot sensor 1 and catalyst hot part) part) sensor 2 temperature, signals reagent activity, exhaust mass flow