1.Scope
This Regulation applies to the emission of gaseous and particulate pollutants from C.I. engines:
Used in category T vehicles 1 having an installed net power higher than 18 kW but not more than 560 kW,
Used in non-road mobile machinery1 having an installed net power higher than 18 kW but not more than 560 kW, operated under variable speed.
Used in non-road mobile machinery1 having an installed net power higher than 18 kW, but not more than 560 kW, operated under constant speed.
2.Definitions and abbreviations
For the purpose of this Regulation,
"Adjustment factors" mean additive (upward adjustment factor and downward adjustment factor) or multiplicative factors to be considered during the periodic (infrequent) regeneration;
"Applicable emission limit" means an emission limit to which an engine is subject;
"Approval of an engine" means the approval of an engine type or family with regard to the level of emission of gaseous and particulate pollutants by the engine;
"Aqueous condensation" means the precipitation of water-containing constituents from a gas phase to a liquid phase. Aqueous condensation is a function of humidity, pressure, temperature, and concentrations of other constituents such as sulphuric acid. These parameters vary as a function of engine intake-air humidity, dilution-air humidity, engine air-to-fuel ratio, and fuel composition - including the amount of hydrogen and sulphur in the fuel;
"Atmospheric pressure" means the wet, absolute, atmospheric static pressure. Note that if the atmospheric pressure is measured in a duct, negligible pressure losses shall be ensured between the atmosphere and the measurement location, and changes in the duct's static pressure resulting from the flow shall be accounted for;
"Calibration" means the process of setting a measurement system's response so that its output agrees with a range of reference signals. Contrast with "verification";
"Calibration gas" means a purified gas mixture used to calibrate gas analysers. Calibration gases shall meet the specifications of paragraph 9.5.1. Note that calibration gases and span gases are qualitatively the same, but differ in terms of their primary function. Various performance verification checks for gas analysers and sample handling components might refer to either calibration gases or span gases;
As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3) (ECE/TRANS/WP.29/78/Rev.2, para. 2) - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
"Compression ignition (C.I.) engine" means an engine which works on the compression-ignition principle (e.g. diesel engine);
"Constant-speed engine" means an engine whose type approval or certification is limited to constant-speed operation. Engines whose constant-speed governor function is removed or disabled are no longer constant-speed engines;
"Constant-speed operation" means engine operation with a governor that automatically controls the operator's demand to maintain engine speed, even under changing load. Governors do not always maintain exactly constant speed. Typically, speed can decrease (0.1 to 10) per cent below the speed at zero load, such that the minimum speed occurs near the engine's point of maximum power;
"Continuous regeneration" means the regeneration process of an exhaust after- treatment system that occurs either in a sustained manner or at least once over the applicable transient test cycle or ramped-modal cycle; in contrast to periodic (infrequent) regeneration;
"Conversion efficiency of non-methane cutter (NMC) E" means the efficiency of the conversion of a NMC that is used for removing the non-methane hydrocarbons from the sample gas by oxidizing all hydrocarbons except methane. Ideally, the conversion for methane is 0 per cent (ECH4 = 0) and for the other hydrocarbons represented by ethane is 100 per cent (EC2H6 = 100 per cent). For the accurate measurement of NMHC, the two efficiencies shall be determined and used for the calculation of the NMHC emission mass flow rate for methane and ethane. Contrast with "penetration fraction";
"Delay time" means the difference in time between the change of the component to be measured at the reference point and a system response of 10 per cent of the final reading (t10) with the sampling probe being defined as the reference point. For the gaseous components, this is the transport time of the measured component from the sampling probe to the detector (see
"DeNOx system" means an exhaust after-treatment system designed to reduce emissions of oxides of nitrogen (NOx) (e.g. passive and active lean NOx catalysts, NOx adsorbers and selective catalytic reduction (SCR) systems);
"Dew point" means a measure of humidity stated as the equilibrium temperature at which water condenses under a given pressure from moist air with a given absolute humidity. Dew point is specified as a temperature in °C or K, and is valid only for the pressure at which it is measured;
"Discrete-mode" means relating to a discrete-mode type of steady-state test, as described in paragraph 7.4.1.1. and Annex 5;
"Drift" means the difference between a zero or calibration signal and the respective value reported by a measurement instrument immediately after it was used in an emission test, as long as the instrument was zeroed and spanned just before the test;
"Electronic control unit" means an engine's electronic device that uses data from engine sensors to control engine parameters;
"Emission control system" means any device, system, or element of design that controls or reduces the emissions of regulated pollutants from an engine;
"Emission control strategy" means a combination of an emission control system with one base emission control strategy and with one set of auxiliary emission control strategies, incorporated into the overall design of an engine or non-road mobile machinery into which the engine is installed; 2.1.21 "Emission durability period" means the number of hours indicated in Annex 8 used to determine the deterioration factors;
"Engine family" means a manufacturer's grouping of engines which, through their design, are expected to have similar exhaust emission characteristics and comply with the requirements in paragraph 7. of this Regulation;
"Engine governed speed" means the engine operating speed when it is controlled by the installed governor;
"Engine system" means the engine, the emission control system and the communication interface (hardware and messages) between the engine system electronic control unit(s) (ECU) and any other powertrain or vehicle control unit;
"Engine type" means a category of engines which do not differ in such essential engine characteristics as defined in paragraphs 1. to 4. of Annex 1A, Appendix 3 to this Regulation;
"Exhaust after-treatment system" means a catalyst, particulate filter, deNOx system, combined deNOx particulate filter or any other emission-reducing device that is installed downstream of the engine. This definition excludes exhaust gas recirculation (EGR) and turbochargers, which are considered an integral part of the engine;
"Exhaust-gas recirculation" means a technology that reduces emissions by routing exhaust gases that had been exhausted from the combustion chamber(s) back into the engine to be mixed with incoming air before or during combustion. The use of valve timing to increase the amount of residual exhaust gas in the combustion chamber(s) that is mixed with incoming air before or during combustion is not considered exhaust-gas recirculation for the purposes of this Regulation;
"Full flow dilution method" means the process of mixing the total exhaust flow with dilution air prior to separating a fraction of the diluted exhaust stream for analysis;
"Gaseous pollutants" means carbon monoxide, hydrocarbons (assuming a ratio of C1H1.85) and oxides of nitrogen, the last named being expressed in nitrogen dioxide (NO2) equivalent;
"Good engineering judgment" means judgments made consistent with generally accepted scientific and engineering principles and available relevant information;
"HEPA filter" means high-efficiency particulate air filters that are rated to achieve a minimum initial particle-removal efficiency of 99.97 per cent using ASTM F 1471–93 or equivalent standard;
"Hydrocarbon (HC)" means THC, NMHC as applicable. Hydrocarbon generally means the hydrocarbon group on which the emission standards are based for each type of fuel and engine;
"High speed (nhi)" means the highest engine speed where 70 per cent of the maximum power occurs;
"Idle speed" means the lowest engine speed with minimum load (greater than or equal to zero load), where an engine governor function controls engine speed. For engines without a governor function that controls idle speed, idle speed means the manufacturer-declared value for lowest engine speed possible with minimum load. Note that warm idle speed is the idle speed of a warmed- up engine;
"Intermediate speed" means that engine speed which meets one of the following requirements:
(a) For engines which are designed to operate over a speed range on a full load torque curve, the intermediate speed shall be the declared maximum torque speed if it occurs between 60 per cent and 75 per cent of the rated speed;
(b) If the declared maximum torque speed is less than 60 per cent of the rated speed, then the intermediate speed shall be 60 per cent of the rated speed;
(c) If the declared maximum torque speed is greater than 75 per cent of the rated speed then the intermediate speed shall be 75 per cent of the rated speed.
"Linearity" means the degree to which measured values agree with respective reference values. Linearity is quantified using a linear regression of pairs of measured values and reference values over a range of values expected or observed during testing;
"Low speed (nlo)" means the lowest engine speed where 50 per cent of the maximum power occurs;
"Maximum power (Pmax)" means the maximum power in kW as designed by the manufacturer;
"Maximum torque speed" means the engine speed at which the maximum torque is obtained from the engine, as specified by the manufacturer;
"Means of a quantity" based upon flow-weighted mean values means the mean level of a quantity after it is weighted proportionally to the corresponding flow rate;
"Net power" means the power in "ECE kW" obtained on the test bench at the end of the crankshaft, or its equivalent, measured in accordance with the method described in Regulation No. 120 on the measurement of the net power, net torque and specific fuel consumption of internal combustion engines for agricultural and forestry tractors and non-road mobile machinery.
"Non-methane hydrocarbons (NMHC)" means the sum of all hydrocarbon species except methane;
"Open crankcase emissions" means any flow from an engine's crankcase that is emitted directly into the environment;
"Operator demand" means an engine operator's input to control engine output. The "operator" may be a person (i.e. manual), or a governor (i.e., automatic) that mechanically or electronically signals an input that demands engine output. Input may be from an accelerator pedal or signal, a throttle-control lever or signal, a fuel lever or signal, a speed lever or signal, or a governor setpoint or signal;
"Oxides of nitrogen" means compounds containing only nitrogen and oxygen as measured by the procedures specified in this Regulation. Oxides of nitrogen are expressed quantitatively as if the NO is in the form of NO2, such that an effective molar mass is used for all oxides of nitrogen equivalent to that of NO2;
"Parent engine" means an engine selected from an engine family in such a way that its emissions characteristics are representative for that engine family and that it complies with the requirements set out in Annex 1B of this Regulation;
"Partial pressure" means the pressure, p, attributable to a single gas in a gas mixture. For an ideal gas, the partial pressure divided by the total pressure is equal to the constituent's molar concentration, x;
"Particulate after-treatment device" means an exhaust after-treatment system designed to reduce emissions of particulate pollutants (PM) through a mechanical, aerodynamic, diffusional or inertial separation;
"Partial flow dilution method" means the process of separating a part from the total exhaust flow, then mixing it with an appropriate amount of dilution air prior to the particulate sampling filter;
"Particulate matter (PM)" means any material collected on a specified filter medium after diluting C.I. engine exhaust gas with clean filtered air so that the temperature does not exceed 325 K (52 °C);
"Penetration fraction PF" means the deviation from ideal functioning of a non- methane cutter (see Conversion efficiency of non-methane cutter (NMC) E). An ideal non-methane cutter would have a methane penetration factor, PFCH4, of 1.000 (that is, a methane conversion efficiency ECH4 of 0), and the penetration fraction for all other hydrocarbons would be 0.000, as represented by PFC2H6 (that is, an ethane conversion efficiency EC2H6 of 1). The relationship is: PFCH4 = 1 – ECH4 and PFC2H6 = 1 – EC2H6;
"Per cent load" means the fraction of the maximum available torque at an engine speed;
"Periodic (or infrequent) regeneration" means the regeneration process of an exhaust after-treatment system that occurs periodically in typically less than 100 hours of normal engine operation. During cycles where regeneration occurs, emission standards may be exceeded;
"Placing on the market" means the action of making available a product covered by this Regulation on the market of a country applying this Regulation, for payment or free of charge, with a view to distribution and/or use in the country;
"Probe" means the first section of the transfer line which transfers the sample to next component in the sampling system;
"PTFE" means polytetrafluoroethylene, commonly known as Teflon TM;
"Ramped modal steady state test cycle" means a test cycle with a sequence of steady state engine test modes with defined speed and torque criteria at each mode and defined speed and torque ramps between these modes;
"Rated speed" means the maximum full load speed allowed by the governor, as designed by the manufacturer, or, if such a governor is not present, the speed at which the maximum power is obtained from the engine, as designed by the manufacturer;
"Reagent" means any consumable or non-recoverable medium required and used for the effective operation of the exhaust after-treatment system;
"Regeneration" means an event during which emissions levels change while the aftertreatment performance is being restored by design. Two types of regeneration can occur: continuous regeneration (see paragraph 6.6.1.) and infrequent (periodic) regeneration (see paragraph 6.6.2.);
"Response time" means the difference in time between the change of the component to be measured at the reference point and a system response of 90 per cent of the final reading (t90) with the sampling probe being defined as the reference point, whereby the change of the measured component is at least 60 per cent full scale (FS) and the devices for gas switching shall be specified to perform the gas switching in less than 0.1 s. The system response time consists of the delay time to the system and of the rise time of the system;
"Rise time" means the difference in time between the 10 per cent and 90 per cent response of the final reading (t90 – t10);
"Shared atmospheric pressure meter" means an atmospheric pressure meter whose output is used as the atmospheric pressure for an entire test facility that has more than one dynamometer test cell;
"Shared humidity measurement" means a humidity measurement that is used as the humidity for an entire test facility that has more than one dynamometer test cell;
"Span" means to adjust an instrument so that it gives a proper response to a calibration standard that represents between 75 per cent and 100 per cent of the maximum value in the instrument range or expected range of use;
"Span gas" means a purified gas mixture used to span gas analysers. Span gases shall meet the specifications of paragraph 9.5.1. Note that calibration gases and span gases are qualitatively the same, but differ in terms of their primary function. Various performance verification checks for gas analysers and sample handling components might refer to either calibration gases or span gases;
"Specific emissions" means the mass emissions expressed in g/kWh;
"Standalone" means something that has no dependencies; it can "stand alone";
"Steady-state" means relating to emission tests in which engine speed and load are held at a finite set of nominally constant values. Steady-state tests are either discrete-mode tests or ramped-modal tests;
"Stoichiometric" means relating to the particular ratio of air and fuel such that if the fuel were fully oxidized, there would be no remaining fuel or oxygen;
"Storage medium" means a particulate filter, sample bag, or any other storage device used for batch sampling;
"Test (or duty) cycle" means a sequence of test points each with a defined speed and torque to be followed by the engine under steady state or transient operating conditions. Duty cycles are specified in the Annex 5. A single duty cycle may consist of one or more test intervals;
"Test interval" means a duration of time over which brake-specific emissions are determined. In cases where multiple test intervals occur over a duty cycle, the Regulation may specify additional calculations that weigh and combine results to arrive at composite values for comparison against the applicable emission limits;
"Tolerance" means the interval in which 95 per cent of a set of recorded values of a certain quantity shall lie, with the remaining 5 per cent of the recorded values deviating from the tolerance interval. The specified recording frequencies and time intervals shall be used to determine if a quantity is within the applicable tolerance;
"Total hydrocarbon (THC)" means the combined mass of organic compounds measured by the specified procedure for measuring total hydrocarbon, expressed as a hydrocarbon with a hydrogen-to-carbon mass ratio of 1.85:1;
"Transformation time" means the difference in time between the change of the component to be measured at the reference point and a system response of 50 per cent of the final reading (t50) with the sampling probe being defined as the reference point. The transformation time is used for the signal alignment of different measurement instruments. See Figure 3.1;
"Transient test cycle" means a test cycle with a sequence of normalized speed and torque values that vary relatively quickly with time (NRTC);
"Type approval" means the approval of an engine type with regard to its emissions measured in accordance with the procedures specified in this Regulation;
"Updating-recording" means the frequency at which the analyser provides new, current, values;
"Useful life" means the relevant period of distance and/or time over which compliance with the relevant gaseous and particulate emission limits has to be assured;
"Variable-speed engine" means an engine that is not a constant-speed engine;
"Verification" means to evaluate whether or not a measurement system's outputs agree with a range of applied reference signals to within one or more predetermined thresholds for acceptance. Contrast with "calibration";
"To zero" means to adjust an instrument so it gives a zero response to a zero calibration standard, such as purified nitrogen or purified air for measuring concentrations of emission constituents;
"Zero gas" means a gas that yields a zero response in an analyser. This may either be purified nitrogen, purified air, a combination of purified air and purified nitrogen.
Symbols and abbreviations
Symbols
The symbols are explained in Annex 4A, paragraph 1.4. and Annex 4B, paragraph 3.2. respectively.
Symbols and abbreviations for the chemical components
Ar Argon C1 Carbon 1 equivalent hydrocarbon CH4 Methane C2H6 Ethane C3H8 Propane CO Carbon monoxide CO2 Carbon dioxide DOP Di-octylphthalate H Atomic hydrogen H2 Molecular hydrogen HC Hydrocarbon H2O Water He Helium N2 Molecular nitrogen NMHC Non-methane hydrocarbon NOx Oxides of nitrogen NO Nitric oxide NO2 Nitrogen dioxide
O2 Oxygen PM Particulate matter PTFE Polytetrafluoroethylene S Sulphur THC Total hydrocarbon
Abbreviations
ASTM American Society for Testing and Materials BMD Bag mini-diluter BSFC Brake-specific fuel consumption CFV Critical Flow Venturi CI Compression-ignition CLD Chemiluminescent Detector CVS Constant Volume Sampler DeNOx NOx after-treatment system DF Deterioration factor ECM Electronic control module EFC Electronic flow control EGR Exhaust gas recirculation FID Flame Ionization Detector GC Gas Chromatograph HCLD Heated Chemiluminescent Detector HFID Heated Flame Ionization Detector IBP Initial boiling point ISO International Organization for Standardization LPG Liquefied Petroleum Gas NDIR Nondispersive infrared (Analyser) NDUV Nondispersive ultraviolet (Analyser) NIST US National Institute for Standards and Technology NMC Non-Methane Cutter PDP Positive Displacement Pump %FS Per cent of full scale PFD Partial Flow Dilution PFS Partial Flow System PTFE Polytetrafluoroethylene (commonly known as Teflon™) RMC Ramped-modal cycle RMS Root-mean square
RTD Resistive temperature detector SAE Society of Automotive Engineers SSV Subsonic Venturi UCL Upper confidence limit UFM Ultrasonic flow-meter
3.Application for approval
Application for approval of an engine as a separate technical unit
The application for approval of an engine or an engine family with regard to the level of the emission of gaseous and particulate pollutants shall be submitted by the engine manufacturer or by a duly accredited representative.
It shall be accompanied by the undermentioned documents in triplicate and the following particulars: A description of the engine type comprising the particulars referred to in Annex 1A of this Regulation and if applicable the particulars of the engine family as referred to in Annex 1B of this Regulation.
An engine conforming to the engine type characteristics described in Annex 1A shall be submitted to the technical service responsible for conducting the approval tests defined in paragraph 5. If the technical service determines that the submitted engine does not fully represent the engine family described in Annex 1A, Appendix 2, an alternative and, if necessary, an additional engine shall be submitted for test according to paragraph 5.
4.Approval
If the engine submitted for approval pursuant to paragraph 3.1. of this Regulation meets the requirements of paragraph 5.2. below, approval of that type of engine or family of engines shall be granted.
An approval number shall be assigned to each type or family approved. Its first two digits shall indicate the series of amendments (at present 01) incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. The same Contracting Party shall not assign the same number to another engine type or family.
Notice of approval or of extension or refusal of approval of an engine type or family pursuant to this Regulation shall be communicated to the Parties to the 1958 Agreement which apply this Regulation, by means of a form conforming to the model in Annex 2, as applicable, to this Regulation. Values measured during the type test shall also be shown.
There shall be affixed, conspicuously and in a readily accessible place to every engine conforming to an engine type or family approved under this Regulation, an international approval mark consisting of:
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval 2;
The number of this Regulation, followed by the letter "R", a dash and the approval number to the right of the circle prescribed in paragraph 4.4.1.
An additional symbol consisting of a letter from D to R indicating the emission level (paragraph 5.2.1.) according to which the engine or the engine family has been approved.
If the engine conforms to an approved type or family under one or more
Regulations Annexed to the Agreement, in the country which has granted approval under this Regulation, the symbol prescribed need not be repeated; in such a case, the regulation and approval numbers and the additional symbols of all the Regulations under which approval has been granted under this Regulation shall be placed in vertical columns to the right of the symbol prescribed in paragraph 4.4.2.
The approval mark shall be placed close to or on the data plate affixed by the manufacturer to the approved type.
Annex 3 to this Regulation gives examples of arrangements of approval marks.
The engine approved as a technical unit shall bear, in addition to the approval mark:
The trademark or trade name of the manufacturer of the engine;
The manufacturer's engine code;
These marks shall be clearly legible and indelible.
5.Specification and tests
General
The components liable to affect the emission of gaseous and particulate pollutants shall be so designed, constructed and assembled as to enable the engine, in normal use, despite the vibrations to which it may be subjected, to comply with the provisions of this Regulation.
The technical measures taken by the manufacturer shall be such as to ensure that the mentioned emissions are effectively limited, pursuant to this Regulation, throughout the normal life of the engine and under normal conditions of use. These provisions are deemed to be met:
(a) If the provisions of paragraphs 5.2.1. and 7.2.2.1. are respectively complied with, and
(b) If, in addition, for engines of power bands L and upwards, the provisions of paragraph 5.3. are complied with.
The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.2/Amend.1 - www.unece.org/trans/main/wp29/wp29wgs/wp29gen/wp29resolutions.html
For engines of power bands H and upwards, the manufacturer shall prove the durability of the engine and after-treatment device, if applicable, in accordance with Annex 8.
Systematic replacement of emission related components, after a certain running time of the engine, is permissible. Any adjustment, repair, disassembly, cleaning or replacement of engine components or systems which is performed on a periodic basis to prevent malfunction of the engine, shall only be done to the extent that is technologically necessary to ensure proper functioning of the emission control system. Accordingly, scheduled maintenance requirements shall be included in the customer's manual and be approved before an approval is granted. For engines of power bands L and upwards, further information shall be included according to the requirements of paragraph 5.3.3.
The corresponding extract from the manual with respect to maintenance/replacements of the after-treatment device(s) shall be included in the information document as set out in the appendices of Annex 1A to this Regulation.
Specifications concerning the emissions of pollutants
The gaseous and particulate components emitted by the engine submitted for testing shall be measured by the methods described in Annex 4A for the power bands up to P, and in Annex 4B for power bands Q and R. At the request of the manufacturer and with the agreement of the Type Approval Authority the methods described in Annex 4B may be used for power bands up to P.
The emissions of the carbon monoxide, the emissions of hydrocarbons, the emissions of the oxides of nitrogen and the emissions of particulate matter obtained shall not exceed the amount shown in the table below:
Net power Carbon monoxide Hydrocarbons Oxides of nitrogen Particulate Matter Power (P) (CO) (HC) (NOx) (PM) band (kW) (g/kWh) (g/kWh) (g/kWh) (g/kWh)
E 130 ≤ P ≤ 560 3.5 1.0 6.0 0.2
F 75 ≤ P < 130 5.0 1.0 6.0 0.3
G 37 ≤ P < 75 5.0 1.3 7.0 0.4
D 18 ≤ P < 37 5.5 1.5 8.0 0.8
Sum of hydro-carbons and oxides Net power Carbon monoxide Particulate Matter of nitrogen (P) (CO) (PM) (HC + NOx) (kW) (g/kWh) (g/kWh) (g/kWh)
H 130 ≤ P ≤ 560 3.5 4.0 0.2
I 75 ≤ P < 130 5.0 4.0 0.3
J 37 ≤ P < 75 5.0 4.7 0.4
K 19 ≤ P < 37 5.5 7.5 0.6
Net power Carbon monoxide Hydrocarbons Oxides of nitrogen Particulate Matter (P) (CO) (HC) (NOx) (PM) (kW) (g/kWh) (g/kWh) (g/kWh) (g/kWh)
L 130 ≤ P ≤ 560 3.5 0.19 2.0 0.025
M 75 ≤ P < 130 5.0 0.19 3.3 0.025
N 56 ≤ P < 75 5.0 0.19 3.3 0.025
Sum of hydro-carbons and oxides of nitrogen (HC + NOx) (g/kWh)
P 37 ≤ P < 56 5.0 4.7 0.025
Net power Carbon monoxide Hydrocarbons Oxides of nitrogen Particulate Matter (P) (CO) (HC) (NOx) (PM) (kW) (g/kWh) (g/kWh) (g/kWh) (g/kWh)
Q 130 ≤ P ≤ 560 3.5 0.19 0.4 0.025
R 56 ≤ P < 130 5.0 0.19 0.4 0.025
The limit values for power bands H to R shall include deterioration factors calculated in accordance with Annex 8.
Where, as defined, according to Annex 1B, one engine family covers more than one power band, the emission values of the parent engine (type approval) and of all engine types within the same family (COP) shall meet the more stringent requirements of the higher power band.
Type approval requirements for power bands L to R
This paragraph shall apply to the type approval of electronically controlled engines, which use electronic control to determine both the quantity and timing of injecting fuel (hereafter 'engine'). This paragraph shall apply irrespective of the technology applied to such engines so as to comply with the emission limit values set out in paragraph 5.2.1. of this Regulation.
General requirements
Requirements for base emission control strategy
The base emission control strategy, activated throughout the speed and torque operating range of the engine, shall be designed as to enable the engine to comply with the provisions of this Regulation.
Any base emission control strategy that can distinguish engine operation between a standardized type approval test and other operating conditions and subsequently reduce the level of emission control when not operating under conditions substantially included in the type approval procedure is prohibited.
Requirements for auxiliary emission control strategy
An auxiliary emission control strategy may be used by an engine or a non-road mobile machine, provided that the auxiliary emission control strategy, when activated, modifies the base emission control strategy in response to a specific set of ambient and/or operating conditions but does not permanently reduce the effectiveness of the emission control system.
(a) Where the auxiliary emission control strategy is activated during the type approval test, paragraphs 5.3.2.2.2. and 5.3.2.2.3. shall not apply.
(b) Where the auxiliary emission control strategy is not activated during the type approval test, it shall be demonstrated that the auxiliary emission control strategy is active only for as long as required for the purposes identified in paragraph 5.3.2.2.3. 5.3.2.2.2 The control conditions applicable to this paragraph are all of the following:
(a) An altitude not exceeding 1,000 metres (or equivalent atmospheric pressure of 90 kPa);
(b) An ambient temperature within the range 275 K to 303 K (2 °C to 30 °C);
(c) The engine coolant temperature above 343 K (70 °C). Where the auxiliary emission control strategy is activated when the engine is operating within the control conditions set out in sub-paragraphs (a), (b) and (c), the strategy shall only be activated exceptionally.
An auxiliary emission control strategy may be activated in particular for the following purposes:
(a) By on-board signals, for protecting the engine (including air-handling device protection) and/or non-road mobile machine into which the engine is installed from damage;
(b) For operational safety and strategies;
(c) For prevention of excessive emissions, during cold start or warming-up, during shut-down;
(d) If used to trade-off the control of one regulated pollutant under specific ambient or operating conditions, for maintaining control of all other regulated pollutants, within the emission limit values that are appropriate for the engine concerned. The purpose is to compensate for naturally occurring phenomena in a manner that provides acceptable control of all emission constituents.
The manufacturer shall demonstrate to the technical service at the time of the type approval test that the operation of any auxiliary emission strategy complies with the provisions of paragraph 5.3.2.2. The demonstration shall consist of an evaluation of the documentation referred to in paragraph 5.3.2.3.
Any operation of an auxiliary emission control strategy not compliant with paragraph 5.3.2.2. is prohibited.
Documentation requirements
The manufacturer shall provide an information folder accompanying the application for type approval at the time of submission to the technical service, which ensures access to any element of design and emission control strategy and the means by which the auxiliary strategy directly or indirectly controls the output variables. The information folder shall be made available in two parts:
(a) The documentation package, annexed to the application for type approval, shall include a full overview of the emission control strategy. Evidence shall be provided that all outputs permitted by a matrix, obtained from the range of control of the individual unit inputs, have been identified. This evidence shall be attached to the information folder as referred to in Annex 1 A.
(b) The additional material, presented to the technical service but not annexed to the application for type approval, shall include all the modified parameters by any auxiliary emission control strategy and the boundary conditions under which this strategy operates and in particular:
(i) A description of the control logic and of timing strategies and switch points, during all modes of operation for the fuel and other essential systems, resulting in effective emissions control (such as exhaust gas recirculation system (EGR) or reagent dosing);
(ii) A justification for the use of any auxiliary emission control strategy applied to the engine, accompanied by material and test data, demonstrating the effect on exhaust emissions. This justification may be based on test data, sound engineering analysis, or a combination of both;
(iii) A detailed description of algorithms or sensors (where applicable) used for identifying, analysing, or diagnosing incorrect operation of the NOx control system;
(iv) The tolerance used to satisfy the requirements in paragraph 5.3.3.7.2., regardless of the used means.
The additional material referred to in sub-paragraph (b) of paragraph 5.3.2.3.1. shall be treated as strictly confidential. It shall be made available to the Type Approval Authority on request. The Type Approval Authority shall treat this material as confidential.
Requirements to ensure correct operation of NOx control measures
3.1. The manufacturer shall provide information that fully describes the functional operational characteristics of the NOx control measures using the documents set out in paragraph 2. of Appendix 1 and paragraph 2. of Appendix 3 to Annex 1A.
If the emission control system requires a reagent, the characteristics of that reagent, including the type of reagent, information on concentration when the reagent is in solution, operational temperature conditions and reference to international standards for composition and quality shall be specified by the manufacturer, in paragraph 2.2.1.13. of Appendix 1 and in paragraph 3.2.1.13. of Appendix 3 to Annex 1A.
The engine emission control strategy shall be operational under all environmental conditions regularly pertaining in the territory of the Community, especially at low ambient temperatures.
The manufacturer shall demonstrate that the emission of ammonia during the applicable emission test cycle of the type approval procedure, when a reagent is used, does not exceed a mean value of 25 ppm.
If separate reagent containers are installed on or connected to a non-road mobile machine, means for taking a sample of the reagent inside the containers shall be included. The sampling point shall be easily accessible without requiring the use of any specialized tool or device.
Use and maintenance requirements
The type approval shall be made conditional, in accordance with paragraph 5.1.3., upon providing to each operator of non-road mobile machinery written instructions comprising the following:
(a) Detailed warnings, explaining possible malfunctions generated by incorrect operation, use or maintenance of the installed engine, accompanied by respective rectification measures;
(b) Detailed warnings on the incorrect use of the machine resulting in possible malfunctions of the engine, accompanied by respective rectification measures;
(c) Information on the correct use of the reagent, accompanied by an instruction on refilling the reagent between normal maintenance intervals;
(d) A clear warning, that the type approval certificate, issued for the type of engine concerned, is valid only when all of the following conditions are met:
(i) The engine is operated, used and maintained in accordance with the instructions provided;
(ii) Prompt action has been taken for rectifying incorrect operation, use or maintenance in accordance with the rectification measures indicated by the warnings referred to in sub-paragraphs (a) and (b);
(iii) No deliberate misuse of the engine has taken place, in particular de-activating or not maintaining an EGR or reagent dosing system. The instructions shall be written in a clear and non-technical manner using the same language as is used in the operator's manual on non-road mobile machinery or engine.
Reagent control (where applicable)
The type approval shall be made conditional, in accordance with the provisions of paragraph 6.1., upon providing indicators or other appropriate means, according to the configuration of the non-road mobile machinery, informing the operator on:
(a) The amount of reagent remaining in the reagent storage container and by an additional specific signal, when the remaining reagent is less than 10 per cent of the full container's capacity;
(b) When the reagent container becomes empty, or almost empty;
(c) When the reagent in the storage tank does not comply with the characteristics declared and recorded in paragraph 2.2.1.13. of Appendix 1 and paragraph 2.2.1.13. of Appendix 3 to Annex 1A, according to the installed means of assessment;
(d) When the dosing activity of the reagent is interrupted, in cases other than those executed by the engine ECU or the dosing controller, reacting to engine operating conditions where the dosing is not required, provided that these operating conditions are made available to the Type Approval Authority.
By the choice of the manufacturer the requirements of reagent compliance with the declared characteristics and the associated NOx emission tolerance shall be satisfied by one of the following means:
(a) Direct means, such as the use of a reagent quality sensor.
(b) Indirect means, such as the use of a NOx sensor in the exhaust to evaluate reagent effectiveness.
(c) Any other means provided that its efficacy is at least equal to the one resulting by the use of the means of sub-paragraphs (a) or (b) and the main requirements of this paragraph are maintained.
6.Installation on the vehicle
The engine installation on the vehicle shall comply with the following characteristics in respect to the approval of the engine.
Intake depression shall not exceed that specified for the approved engine in Annex 1A, Appendix 1.
Exhaust back pressure shall not exceed that specified for the approved engine in Annex 1A, Appendix 1.
The operator shall be informed on the reagent control as defined in paragraph 5.3.3.7.1., if applicable.
7.Conformity of production
The conformity of production procedures shall comply with those set out in the Agreement, Appendix 2 (E/ECE/324-E/ECE/TRANS/505/Rev.2) with the following requirements:
The Type Approval Authority which has granted approval may at any time verify the conformity control methods applicable to each production unit.
In every inspection, the test books and production survey record shall be presented to the visiting inspector.
When the quality level appears unsatisfactory or when it seems necessary to verify the validity of the data presented in application of paragraph 5.2., the following procedure is adopted:
An engine is taken from the series and subjected to the test described in Annex 4A or Annex 4B according to paragraph 5.2. The emissions of the carbon monoxide, the emissions of the hydrocarbons, the emissions of the oxides of nitrogen and the emissions of particulate obtained shall not exceed the amounts shown in the table in paragraph 5.2.1., subject to the requirements of paragraph 5.2.2.
If the engine taken from the series does not satisfy the requirements of paragraph 7.2.2.1. the manufacturer may ask for measurements to be performed on a sample of engines of the same specification taken from the series and including the engine originally taken. The manufacturer shall determine the size n of the sample in agreement with the technical service. Engines other than the engine originally taken shall be subjected to a test. The arithmetical mean (x ) of the results obtained with the sample shall then be determined for each pollutant. The production of the series shall then be deemed to confirm if the following condition is met:
x + kS ≤ l where:
∑ (x - x )2 S = where x is any one of the individual results obtained with n-1 the sample n; l is the limit value laid down in paragraph 5.2.1. for each pollutant considered; k is a statistical factor depending on n and given in the following table:
n 2 3 4 5 6 7 8 9 10
k 0.973 0.613 0.489 0.421 0.376 0.342 0.317 0.296 0.279
n 11 12 13 14 15 16 17 18 19
k 0.265 0.253 0.242 0.233 0.224 0.216 0.210 0.203 0.198
0.860 if n ≥ 20, k= n
The Technical Service responsible for verifying the conformity of production shall carry out tests on engines which have been run-in partially or completely, according to the manufacturer's specifications.
The normal frequency of inspections authorized by the Type Approval
Authority shall be one per year. If the requirements of paragraph 7.2.2.1. are not met, the Type Approval Authority shall ensure that all necessary steps are taken to re-establish the conformity of production as rapidly as possible.
8.Penalties for non-conformity of production
The approval granted in respect of an engine type or family pursuant to this Regulation may be withdrawn if the requirements laid down in paragraph 7.2. are not complied with or if the engine or engines taken fail to pass the tests prescribed in paragraph 7.2.2.1.
If a Contracting Party to the Agreement applying this Regulation withdraws an approval it has previously granted, it shall forthwith so notify the other Contracting Parties applying this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.
Modifications and extension of approval of the approved type
Every modification of the approved type or family shall be notified to the Type
Approval Authority which approved the type. The Type Approval Authority may then either:
Consider that the modifications made are unlikely to have an appreciable adverse effect and that in any case the modified type still complies with the requirement; or
Require a further test report from the Technical Service conducting the tests.
Confirmation or refusal of approval, specifying the alterations, shall be communicated by the procedure specified to the Parties to the Agreement applying this Regulation.
The Type Approval Authority issuing the extension of approval shall assign a series number for such an extension and inform thereof the other Contracting Parties to the 1958 Agreement applying this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.
10.Production definitively discontinued
If the holder of the approval completely ceases to manufacture the type or family approved in accordance with this Regulation he shall so inform the authority which granted the approval. Upon receiving the relevant communication that authority shall inform thereof the other Parties to the Agreement which apply this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.
11.Transitional provisions
As from the official date of entry into force of the 02 series of amendments, no Contracting Party applying this Regulation shall refuse to grant approval under this Regulation as amended by the 02 series of amendments.
As from the date of entry into force of the 02 series of amendments, Contracting Parties applying this Regulation may refuse to grant approvals to variable speed engines, or engine families, of the power bands H, I, J and K which do not meet the requirements of this Regulation as amended by the 02 series of amendments.
As from the date of entry into force of the 02 series of amendments, Contracting Parties applying this Regulation may refuse the placing on the market of variable speed engines, or engine families, included in the power bands H, I, J and K not approved under this Regulation as amended by the series 02 of amendments.
As from 1 January 2010, Contracting Parties applying this Regulation may refuse to grant approvals to constant speed engines, or engine families, of the power bands H, I and K which do not meet the requirements of this Regulation as amended by the 02 series of amendments.
As from 1 January 2011, Contracting Parties applying this Regulation may refuse to grant approvals to constant speed engines, or engine families, of the power band J which do not meet the requirements of this Regulation as amended by the 02 series of amendments.
As from 1 January 2011, Contracting Parties applying this Regulation may refuse the placing on the market of constant speed engines, or engine families, included in the power bands H, I and K not approved under this Regulation as amended by the series 02 of amendments.
As from 1 January 2012, Contracting Parties applying this Regulation may refuse the placing on the market of constant speed engines, or engine families, included in the power band J not approved under this Regulation as amended by the series 02 of amendments.
By derogation to the provisions stipulated on paragraphs 11.3., 11.6. and 11.7., Contracting Parties applying this Regulation may postpone each date mentioned in the above paragraphs for two years in respect of engines with a production date prior to the said dates.
By derogation to the provisions stipulated in paragraphs 11.3., 11.6. and 11.7., Contracting Parties applying this Regulation may continue to permit the placing on the market of engines approved on the basis of a previous technical standard, provided that the engines are intended as replacement for fitting in vehicles in use, and that it is not technically feasible for the engines in question to satisfy the new requirements of the 02 series of amendments.
As from the official date of entry into force of the 03 series of amendments, no Contracting Party applying this Regulation shall refuse to grant approval under this Regulation as amended by the 03 series of amendments.
As from the date of entry into force of the 03 series of amendments, Contracting Parties applying this Regulation may refuse to grant approvals to variable speed engines, or engine families, of the power bands L, M, N and P which do not meet the requirements of this Regulation as amended by the 03 series of amendments.
As from 1 January 2013, Contracting Parties applying this Regulation may refuse to grant approvals to variable speed engines, or engine families, of the power band Q which do not meet the requirements of this Regulation as amended by the 03 series of amendments.
As from 1 October 2013, Contracting Parties applying this Regulation may refuse to grant approvals to variable speed engines, or engine families, of the power band R which do not meet the requirements of this Regulation as amended by the 03 series of amendments.
As from the date of entry into force of the 03 series of amendments, Contracting Parties applying this Regulation may refuse the placing on the market of variable speed engines, or engine families, included in the power bands L, M, N and P not approved under this Regulation as amended by the series 03 of amendments.
As from 1 January 2014, Contracting Parties applying this Regulation may refuse the placing on the market of variable speed engines, or engine families, included in the power band Q not approved under this Regulation as amended by the series 03 of amendments.
As from 1 October 2014, Contracting Parties applying this Regulation may refuse the placing on the market of variable speed engines, or engine families, included in the power band R not approved under this Regulation as amended by the series 03 of amendments.
By derogation to the provisions stipulated in paragraphs 11.14. to 11.16. Contracting Parties applying this Regulation shall postpone each date mentioned in the above paragraphs for two years in respect of engines with a production date prior to the said dates.
By derogation to the provisions stipulated in paragraphs 11.14., 11.15. and 11.16., Contracting Parties applying this Regulation may continue to permit the placing on the market of engines approved on the basis of a previous technical standard, provided that the engines are intended as replacement for fitting in vehicles in use, and that it is not technically feasible for the engines in question to satisfy the new requirements of the 03 series of amendments.
Names and addresses of Technical Services responsible for conducting approval tests and of Type Approval Authorities The Contracting Parties to the 1958 Agreement applying this Regulation shall communicate to the United Nations Secretariat the names and addresses of the Technical Services responsible for conducting approval tests and the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, issued in other countries are to be sent.
Annex 1A
Annex 1A
Information document No … relating to the type approval and referring to measures against the emission of gaseous and particulate pollutants from internal combustion engines to be installed in non-road mobile machinery
1.General
Type and commercial description of the parent – and (if applicable) of Name and address of manufacturer's authorized representative Attachments:
Essential characteristics of the (parent) engine(s) (see Appendix 1)
Essential characteristics of the engine family (see Appendix 2)
Essential characteristics of engine types within the family (see Appendix 3)
2.Characteristics of engine-related parts of the mobile machinery (if applicable)
3.Photographs of the parent engine
List further attachments if any Date, file
Strike out what does not apply. Specify the tolerance.
Annex 1A - Appendix 1
Annex 1A - Appendix 1
Essential characteristics of the (parent) engine
1.Description of engine
Cycle: four stroke/two stroke 1
Cooling system
Liquid
Circulating pump(s): yes/no1
Air
Blower: yes/no1
Temperature permitted by the manufacturer
Strike out what does not apply. Specify the tolerance.
Annex 1A - Appendix 1
Maximum charge air outlet temperature of the inlet intercooler (if applicable):K
Maximum exhaust temperature at the point in the exhaust pipe(s) adjacent to
Pressure charger: yes/no1
Description of the system (e.g. max charge pressure, waste-gate, if applicable):
Intercooler: yes/no1
Intake system: Maximum allowable intake depression at rated engine speed and
Exhaust system: Maximum allowable exhaust backpressure at rated engine
2.Measures taken against air pollution
Device for recycling crankcase gases: yes/no1
Additional anti-pollution devices (if any, and if not covered by another heading)
Catalytic converter: yes/no1
Location of the catalytic converter(s) (place(s) and maximum/minimum
Annex 1A - Appendix 1
NOx sensor: yes/no1
Oxygen sensor: yes/no1
Air injection: yes/no1
EGR: yes/no1
Particulate trap: yes/no1
Other systems: yes/no1
3.Fuel feed
Feed pump
Injection system
Pump at full injection, or characteristic diagram. Mention the method used: On engine/on pump bench1
Injection advance
Injection piping
Injector(s)
Annex 1A - Appendix 1
Governor
Cold Start System
4.Valve timing
Maximum lift and angles of opening and closing in relation to dead centres or
Reference and/or setting ranges1
Annex 1A - Appendix 2
Annex 1A - Appendix 2
Essential characteristics of the engine family
1.Common parameters 1
Proof of identical (or lowest for the parent engine) ratio: system capacity/fuel
2.Engine family listing
Strike out what does not apply. Specify the tolerance.
Annex 1A - Appendix 2
Specification of engines within this family:
Rated net Maximum Engine type No. of cylinders Rated speed power (kW) torque speed Maximum torque Low idle speed
Parent engine (for full details see Annex 1A)
In addition, for each engine type within the family, the information required in Annex 1B – Appendix 3 shall be submitted to the Type Approval Authority.
Annex 1A - Appendix 3
Annex 1A - Appendix 3
Essential characteristics of engine types within the family
1.Description of engine
Cycle: four stroke/two stroke 1
Cooling system
Liquid
Circulating pump(s): yes/no1
Air
Blower: yes/no1
Temperature permitted by the manufacturer
Strike out what does not apply. Specify the tolerance.
Annex 1A - Appendix 3
Maximum charge air outlet temperature of the inlet intercooler (if applicable):K
Maximum exhaust temperature at the point in the exhaust pipe(s) adjacent to
Pressure charger: yes/no1
Description of the system (e.g. max. charge pressure, waste-gate, if applicable):
Intercooler: yes/no1
Intake system: Maximum allowable intake depression at rated engine speed and
Exhaust system: Maximum allowable exhaust backpressure at rated engine
2.Measures taken against air pollution
Device for recycling crankcase gases: yes/no1
Additional anti-pollution devices (if any, and if not covered by another heading)
Catalytic converter: yes/no1
Location of the catalytic converter(s) (place(s) and maximum/minimum
Annex 1A - Appendix 3
NOx sensor: yes/no1
Oxygen sensor: yes/no1
Air injection: yes/no1
EGR: yes/no1
Particulate trap: yes/no1
Other systems: yes/no1
3.Fuel feed
Feed pump
Injection system
Pump at full injection, or characteristic diagram. Mention the method used: On engine/on pump bench1
Injection advance
Injection piping
Injector(s)
Annex 1A - Appendix 3
Governor
Cold Start System
4.Valve timing
Maximum lift and angles of opening and closing in relation to dead centres or
Reference and/or setting ranges1
Annex 1B
Annex 1B
Characteristics of the engine family and choice of the parent engine
1.Parameters defining the engine family
General
An engine family is characterized by design parameters. These shall be common to all engines within the family. The engine manufacturer may decide which engines belong to an engine family, as long as the membership criteria listed in paragraph 1.3. are respected. The engine family shall be approved by the Type Approval Authority. The manufacturer shall provide to the Type Approval Authority the appropriate information relating to the emission levels of the members of the engine family.
Special cases
Interactions between parameters
In some cases there may be interaction between parameters, which may cause emissions to change. This shall be taken into consideration to ensure that only engines with similar exhaust emission characteristics are included within the same engine family. These cases shall be identified by the manufacturer and notified to the Type Approval Authority. It shall then be taken into account as a criterion for creating a new engine family.
Devices or features having a strong influence on emissions
In case of devices or features, which are not listed in paragraph 1.3. and which have a strong influence on the level of emissions, this equipment shall be identified by the manufacturer using good engineering judgment, and shall be notified to the Type Approval Authority. It shall then be taken into account as a criterion for creating a new engine family.
Additional criteria
In addition to the parameters listed in paragraph 1.3., the manufacturer may introduce additional criteria allowing the definition of families of a more restricted size. These parameters are not necessarily parameters that have an influence on the level of emissions.
Parameters defining the engine family
Combustion cycle:
(a) 2-stroke cycle;
(b) 4-stroke cycle;
(c) Rotary engine;
(d) Others.
Annex 1B
Configuration of the cylinders
Position of the cylinders in the block:
(a) V;
(b) In-line;
(c) Radial;
(d) Others (F, W, etc.).
Relative position of the cylinders
Engines with the same block may belong to the same family as long as their bore centre-to-centre dimensions are the same.
Main cooling medium:
(a) Air;
(b) Water;
(c) Oil.
Individual cylinder displacement
Within 85 per cent and 100 per cent for engines with a unit cylinder displacement ≥ 0.75 dm3 of the largest displacement within the engine family. Within 70 per cent and 100 per cent for engines with a unit cylinder displacement < 0.75 dm3 of the largest displacement within the engine family.
Method of air aspiration:
(a) Naturally aspirated;
(b) Pressure charged;
(c) Pressure charged with charge cooler.
Combustion chamber type/design:
(a) Open chamber;
(b) Divided chamber;
(c) Other types.
Valves and porting:
(a) Configuration;
(b) Number of valves per cylinder.
Fuel supply type:
(a) Pump, (high pressure) line and injector;
(b) In-line pump or distributor pump;
(c) Unit injector;
(d) Common rail.
Miscellaneous devices:
(a) Exhaust gas recirculation (EGR);
(b) Water injection;
Annex 1B
(c) Air injection;
(d) Others.
Electronic control strategy
The presence or absence of an electronic control unit (ECU) on the engine is regarded as a basic parameter of the family. In the case of electronically controlled engines, the manufacturer shall present the technical elements explaining the grouping of these engines in the same family, i.e. the reasons why these engines can be expected to satisfy the same emission requirements. The electronic governing of speed does not need to be in a different family from those with mechanical governing. The need to separate electronic engines from mechanical engines should only apply to the fuel injection characteristics, such as timing, pressure, rate shape, etc.
Exhaust after-treatment systems
The function and combination of the following devices are regarded as membership criteria for an engine family:
(a) Oxidation catalyst;
(b) DeNOx system with selective reduction of NOx (addition of reducing agent);
(c) Other DeNOx systems;
(d) Particulate trap with passive regeneration;
(e) Particulate trap with active regeneration;
(f) Other particulate traps;
(g) Other devices. When an engine has been certified without an after-treatment system, whether as parent engine or as member of the family, then this engine, when equipped with an oxidation catalyst (not with particulate trap), may be included in the same engine family, if it does not require different fuel characteristics. If it requires specific fuel characteristics (e.g. particulate traps requiring special additives in the fuel to ensure the regeneration process), the decision to include it in the same family shall be based on technical elements provided by the manufacturer. These elements shall indicate that the expected emission level of the equipped engine complies with the same limit value as the non-equipped engine. When an engine has been certified with after-treatment system, whether as parent engine or as member of a family, whose parent engine is equipped with the same after-treatment system, then this engine, when equipped without after- treatment system, shall not be added to the same engine family.
2.Choice of the parent engine
The parent engine of the family shall be selected using the primary criteria of the highest fuel delivery per stroke at the declared maximum torque speed. In the event that two or more engines share this primary criterion, the parent engine shall be selected using the secondary criteria of highest fuel delivery per stroke at rated speed. Under certain circumstances, the approval authority may
Annex 1B conclude that the worst case emission rate of the family can best be characterized by testing a second engine. Thus, the approval authority may select an additional engine for test based upon features which indicate that it may have the highest emission levels of the engines within that family.
If engines within the family incorporate other variable features which could be considered to affect exhaust emissions, these features shall also be identified and taken into account in the selection of the parent engine.
Annex 2 — Communication
(Maximum format: A4 (210 x 297 mm) issued by : Name of administration:
concerning 2: Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a compression ignition engine type or family of engine types as separate technical units with regard to the emission of pollutants pursuant to Regulation No. 96
Engine type(s):
Distinguishing number of the country which has granted/extended/refused/withdrawn an approval (see approval provisions in the Regulation). Strike out what does not apply.
Annex 2
Emission levels - final test results with DF:
NRSC NRTC
CO (g/kWh)
HC (g/kWh)
NOx (g/kWh)
PM (g/kWh)
The following documents, bearing the approval number shown above, are annexed to this communication: One copy of Annex 1A or Annex 1B to this Regulation completed and with drawings and diagrams referred to attached.
Annex 2 - Appendix 1 — Test results
Information concerning the conduct of the test 1:
Reference fuel used for test
Lubricant (State percentage of oil in mixture if lubricant and fuel are mixed)
Engine driven equipment (if applicable)
Power absorbed at indicated engine speeds (as specified by the manufacturer):
a Power PAE (kW) absorbed at various engine speeds , taking into account Annex 7
Equipment Intermediate (if applicable) Rated
Total: a Shall not be greater than 10 per cent of the power measured during the test.
Engine performance
Engine speeds:
For the case of several parent engines, the following are to be indicated for each of them.
Annex 2 - Appendix 1
Engine power 2
Power setting (kW) at various engine speeds
Condition Intermediate (if applicable) Rated
Maximum power measured on test (PM) (kW) (a)
Total power absorbed by engine driven equipment as per paragraph 1.3.2. of this appendix or Annex 7 (kW) (b)
Net engine power as specified in paragraph 2.1.41. (kW) (c)
c=a+b
Information concerning the conduct of the NRSC test:
Dynamometer setting (kW)
Dynamometer setting (kW) at various engine speeds
Per cent Load Intermediate (if applicable) Rated
10 (if applicable)
25 (if applicable)
Uncorrected power measured in accordance with paragraph 2.1.41.
Emission results of the engine/parent engine 3
Deterioration Factor (DF): calculated/fixed3 Specify the DF values and the emission results in the following table3:
NRSC Test
CO HC NOx PM DF mult/add3
Emissions CO (g/kWh) HC (g/kWh) NOx (g/kWh) PM (g/kWh)
Test result
Final test result with DF
Sampling system used for the NRSC test:
Method3: single/multiple filter
Information concerning the conduct of the NRTC test 5:
Emission results of the engine/parent engine3
Deterioration Factor (DF): calculated/fixed3 Specify the DF values and the emission results in the following table3:
Delete as appropriate. Indicate figure numbers of system used as defined in Annex 4A, Appendix 4. In the case of several parent engines, each of them shall be indicated.
Annex 2 - Appendix 1
NRTC Test
CO HC NOx PM DF mult/add3
Emissions CO (g/kWh) HC (g/kWh) NOx (g/kWh) PM (g/kWh)
Cold start
Emissions CO (g/kWh) HC (g/kWh) NOx (g/kWh) PM (g/kWh)
Hot start w/o regeneration
Hot start with regeneration3
kr,u (mult/add)3 kr,d (mult/add)3
Weighted test result
Final test result with DF
Sampling system used for the NRTC test: Method3: single/multiple filter
Annex 3 — Arrangements of approval marks
Model A
(See paragraph 4.4. of this Regulation)
a 3 F a a E4 a 3 96 R - 031857 a
a = 8 mm min The above approval mark affixed to an engine shows that the engine type concerned has been approved in the Netherlands (E4) pursuant to Regulation No. 96 (according to the level corresponding to power band F) and under approval number 011857. The first two digits of the approval number indicate that Regulation No. 96 was in its amended form (03 series of amendments) when the approval was granted.
Model B
(See paragraph 4.5. of this Regulation)
a 96 F 031857 a
E4 a 2 3 a a 3 a a 2 120 001628 3
a = 8 mm min The above approval mark affixed to an engine shows that the engine type concerned has been approved in the Netherlands (E4) pursuant to Regulations Nos. 96 (according to the level corresponding to power band F) and 120. The first two digits of the approval number indicate that, at the dates when the respective approvals were granted, Regulation No. 96 was in its amended form (03 series of amendments) and 120 in its original version.
Annex 4A
Annex 4A
Method of determining emissions of gaseous and particulate pollutants
1.Introduction
This Annex describes the method of determining emissions of gaseous and particulate pollutants from the engine to be tested. The following test cycles shall apply: The NRSC (non-road steady cycle) appropriate for the equipment specification which shall be used for the measurement of the emissions of carbon monoxide, hydrocarbons, oxides of nitrogen and particulates for all power bands of engines described in paragraphs 1.1., 1.2. and 1.3. of this Regulation, and the NRTC (non-road transient cycle) which shall be used for the measurement of the emissions of carbon monoxide, hydrocarbons, oxides of nitrogen and particulates for power bands L and upwards of engines described in paragraphs 1.1. and 1.2. of this Regulation. The gaseous and particulate components emitted by the engine submitted for testing shall be measured by the methods described in Annex 4A, Appendix 4. Other systems or analysers may be accepted if they yield equivalent results to the following reference systems:
(a) For gaseous emissions measured in the raw exhaust, the system shown in Figure 2 of Annex 4A, Appendix 4;
(b) For gaseous emissions measured in the dilute exhaust of a full flow dilution system, the system shown in Figure 3 of Appendix 4 of Annex 4A;
(c) For particulate emissions, the full flow dilution system, operating with a separate filter for each mode, shown in Figure 13 of Appendix 4 of Annex 4A. The determination of system equivalency shall be based upon a seven test cycle (or larger) correlation study between the system under consideration and one or more of the above reference systems. The equivalency criterion is defined as a ±5 per cent agreement of the averages of the weighted cycle emissions values. The cycle to be used shall be that given in Annex 4A, paragraph 3.6.1. For introduction of a new system into the Regulation the determination of equivalency shall be based upon the calculation of repeatability and reproducibility, as described in ISO 5725.
The test shall be carried out with the engine mounted on a test bench and connected to a dynamometer.
Annex 4A
Measurement principle: The engine exhaust emissions to be measured include the gaseous components (carbon monoxide, total hydrocarbons and oxides of nitrogen), and the particulates. Additionally, carbon dioxide is often used as a tracer gas for determining the dilution ratio of partial and full flow dilution systems. Good engineering practice recommends the general measurement of carbon dioxide as an excellent tool for the detection of measurement problems during the test run.
NRSC test: During a prescribed sequence of operating conditions, with the engines warmed up, the amounts of the above exhaust emissions shall be examined continuously by taking a sample from the raw exhaust gas. The test cycle consists of a number of speed and torque (load) modes, which cover the typical operating range of diesel engines. During each mode, the concentration of each gaseous pollutant, exhaust flow and power output shall be determined, and the measured values weighted (either by weighing factors or by sampling time). The particulate sample shall be diluted with conditioned ambient air. One sample over the complete test procedure shall be taken and collected on suitable filters. Alternatively, for discrete mode cycles, a sample may be taken on separate filters, one for each mode, and cycle-weighted results computed. The grams of each pollutant emitted per kilowatt-hour shall be calculated as described in Appendix 3 to this Annex.
NRTC test: The prescribed transient test cycle, based closely on the operating conditions of diesel engines installed in non-road machinery, is run twice:
(a) The first time (cold start) after the engine has soaked to room temperature and the engine coolant and oil temperatures, after treatment systems and all auxiliary engine control devices are stabilized between 20 and 30 °C.
(b) The second time (hot start) after a twenty-minute hot soak that commences immediately after the completion of the cold start cycle. During this test sequence the above pollutants shall be examined. The test sequence consists of a cold start cycle following natural or forced cool-down of the engine, a hot soak period and a hot start cycle, resulting in a composite emissions calculation. Using the engine torque and speed feedback signals of the engine dynamometer, the power shall be integrated with respect to the time of the cycle, resulting in the work produced by the engine over the cycle. The concentrations of the gaseous components shall be determined over the cycle, either in the raw exhaust gas by integration of the analyser signal in accordance with Appendix 3 to this Annex, or in the diluted exhaust gas of a CVS full-flow dilution system by integration or by bag sampling in accordance with Appendix 3 to this Annex. For particulates, a proportional sample shall be collected from the diluted exhaust gas on a specified filter by either partial flow dilution or full-flow dilution. Depending on the method used, the diluted or undiluted exhaust gas flow rate shall be determined over the cycle to calculate the mass emission values of the pollutants. The mass emission values shall be related to the engine work to give the grams of each pollutant emitted per kilowatt-hour.
Annex 4A
Emissions (g/kWh) shall be measured during both the cold and hot start cycles. Composite weighted emissions shall be computed by weighing the cold start results 10 per cent and the hot start results 90 per cent. Weighted composite results shall meet the limits.
Symbols for test parameters
Symbol Unit Term Ap m2 Cross-sectional area of the isokinetic sampling probe. AT m2 Cross-sectional area of the exhaust pipe. aver Weighted average values for: m /h volume flow; kg/h mass flow; g/kWh specific emission. α - Hydrogen-to-carbon ratio of the fuel. C1 - Carbon 1 equivalent hydrocarbon. conc ppm Concentration (with suffix of Vol % the component nominating). concc ppm Background corrected Vol % concentration. concd ppm Concentration of dilution Vol % air. DF - Dilution factor. fa - Laboratory atmospheric factor. FFH - Fuel specific factor used for the calculations of wet concentrations from dry concentrations hydrogen to carbon ratio. GAIRW kg/h Intake air mass flow rate on wet basis. GAIRD kg/h Intake air mass flow rate on dry basis. GDILW kg/h Dilution air mass flow rate on wet basis. GEDFW kg/h Equivalent diluted exhaust gas mass flow rate on wet basis. GEXHW kg/h Exhaust gas mass flow rate on wet basis. GFUEL kg/h Fuel mass flow rate. GTOTW kg/h Diluted exhaust gas mass flow rate on wet basis. HREF g/kg Reference value of absolute humidity 10.71 g/kg for calculation of NOx and particulate humidity correction factors. Ha g/kg Absolute humidity of the intake air. Hd g/kg Absolute humidity of the dilution air. Annex 4A
i - Subscript denoting an individual mode. KH - Humidity correction factor for NOx. Kp - Humidity correction factor for particulate. KW,a - Dry to wet correction factor for the intake air. KW,d - Dry to wet correction factor for the dilution air. KW,e - Dry to wet correction factor for the diluted exhaust gas. KW,r - Dry to wet correction factor for the raw exhaust gas. L % Per cent torque related to the maximum torque for the test speed. mass g/h Subscript denoting emissions mass flow rate. MDIL kg Mass of the dilution air sample passed through the particulate sampling filters. MSAM kg Mass of the diluted exhaust sample passed through the particulate sampling filters. Md mg Particulate sample mass of the dilution air collected. Mf mg Particulate sample mass collected. pa kPa Saturation vapour pressure of the engine intake air (ISO 3046 psy = PSY test ambient). pB kPa Total barometric pressure (ISO 3046: Px = PX Site ambient total pressure; Py = PY Test ambient total pressure). pd kPa Saturation vapour pressure of the dilution air. ps kPa Dry atmospheric pressure. P kW Power, brake uncorrected. PAE kW Declared total power absorbed by auxiliaries fitted for the test which are not required by paragraph 2.1.41. of this Regulation. PM kW Maximum measured power at the test speed under test conditions (see Annex 1A). Pm kW Power measured at the different test modes. q - Dilution ratio. r - Ratio of cross sectional areas of isokinetic probe and exhaust pipe. Ra % Relative humidity of the intake air. Rd % Relative humidity of the dilution air. Rf - FID response factor. S kW Dynamometer setting.
Annex 4A
Ta K Absolute temperature of the intake air. TDd K Absolute dewpoint temperature. TSC K Temperature of the intercooled air. Tref K Reference temperature (of combustion air 298K (25 °C)). TSCRef K Intercooled air reference temperature. VAIRD m3/h Intake air volume flow rate on dry basis. VAIRW m /h Intake air volume flow rate on wet basis. VDIL m3 Volume of the dilution air sample passed through the particulate sample filters. VDILW m3/h Dilution air volume flow rate on wet basis. VEDFW m3/h Equivalent diluted exhaust gas volume flow rate on wet basis. VEXHD m3/h Exhaust gas volume flow rate on dry basis. VEXHW m3/h Exhaust gas volume flow rate on wet basis. VSAM m Volume of sample through particulate sampling filters. VTOTW m3/h Diluted exhaust gas volume flow rate on wet basis. WF - Weighing factor. WFE - Effective weighing factor.
2.Test conditions
General requirements
All volumes and volumetric flow rates shall be related to 273 K (0 oC) and 101.3 kPa.
Engine test conditions
The absolute temperature Ta of the engine intake air expressed in Kelvin, and the dry atmospheric pressure ps, expressed in kPa, shall be measured, and the parameter fa shall be determined according to the following provisions: Naturally aspirated and mechanically supercharged engines:
⎛ 99 ⎞ ⎛ T ⎞ 0.7 f a=⎜ ⎟⋅⎜ ⎟ ⎝ p s ⎠ ⎝ 298 ⎠ Turbocharged engine with or without cooling of the intake air: 0.7 ⎛ 99 ⎞ ⎛ T ⎞1.5 f a=⎜ ⎟ ⋅⎜ ⎟ ⎝ p s ⎠ ⎝ 298 ⎠
Test validity
For a test to be recognized as valid, the parameter fa shall be such that: 0.96 ≤ fa ≤ 1.06 Annex 4A
Engines with charge air cooling
The charge air temperature shall be recorded and, at the declared rated speed and full load, shall be within ±5 K of the maximum charge air temperature specified by the manufacturer. The temperature of the cooling medium shall be at least 293 K (20 °C). If a test shop system or external blower is used, the charge air temperature shall be set to within ±5 K of the maximum charge air temperature specified by the manufacturer at the speed of the declared maximum power and full load. Coolant temperature and coolant flow rate of the charge air cooler at the above set point shall not be changed for the whole test cycle. The charge air cooler volume shall be based upon good engineering practice and typical vehicle/machinery applications. Optionally, the setting of the charge air cooler may be done in accordance with SAE J 1937 as published in January 1995.
Engine air inlet system
The test engine shall be equipped with an air inlet system presenting an air inlet restriction within ±300 Pa of the value specified by the manufacturer for a clean air cleaner at the engine operating conditions as specified by the manufacturer, which result in maximum air flow. The restrictions are to be set at rated speed and full load. A test shop system may be used, provided it duplicates actual engine operating conditions.
Engine exhaust system
The test engine shall be equipped with an exhaust system with exhaust back pressure within ±650 Pa of the value specified by the manufacturer at the engine operating conditions resulting in maximum declared power. If the engine is equipped with an exhaust after-treatment device, the exhaust pipe shall have the same diameter as found in-use for at least four pipe diameters upstream to the inlet of the beginning of the expansion section containing the after-treatment device. The distance from the exhaust manifold flange or turbocharger outlet to the exhaust after-treatment device shall be the same as in the machine configuration or within the distance specifications of the manufacturer. The exhaust backpressure or restriction shall follow the same criteria as above, and may be set with a valve. The after-treatment container may be removed during dummy tests and during engine mapping, and replaced with an equivalent container having an inactive catalyst support.
Cooling system
An engine cooling system with sufficient capacity to maintain the engine at normal operating temperatures shall be prescribed by the manufacturer.
Lubricating oil
Specifications of the lubricating oil used for the test shall be recorded and presented with the results of the test.
Test fuel
The fuel shall be the reference fuel specified in Annex 6 for the respective power band: Annex 6,, Table 1 for power bands D to G
Annex 4A
Annex 6, Table 2 for power bands H to K Annex 6, Table 3 for power bands L to P Optionally, the reference fuel specified in Annex 6 Table 1 may be used for power bands H to K. The cetane number and the sulphur content of the reference fuel used for test shall be recorded at paragraph 1.1. of Appendix 1 of Annex 2. The fuel temperature at the injection pump inlet shall be 306-316 K (33-43 oC).
3.Test run (NRSC test)
Determination of dynamometer settings
The basis of specific emissions measurement is uncorrected brake power according to Regulation No. 120. During the test, the auxiliaries necessary for the engine operation shall be installed according to the requirements of Annex 7. Where auxiliaries have not been removed, the power absorbed by them at the test speeds shall be determined in order to calculate the dynamometer settings, except for engines where such auxiliaries form an integral part of the engine (e.g. cooling fans for air cool engines). The settings of inlet restriction and exhaust pipe backpressure shall be adjusted to the manufacturer's upper limits, in accordance with paragraphs 2.3. and 2.4. The maximum torque values at the specified test speeds shall be determined by experimentation in order to calculate the torque values for the specified test modes. For engines which are not designed to operate over a range on a full load torque curve, the maximum torque at the test speeds shall be declared by the manufacturer. The engine setting for each test mode shall be calculated using the formula: ⎛ L ⎞ S = ⎜ ( PM + PAE ) ⋅ ⎟ − PAE ⎝ 100 ⎠ If the ratio, PAE ≥ 0.03 PM
the value of PAE may be verified by the Type Approval Authority granting type approval.
Preparation of the sampling filters
At least one hour before the test, each filter (pair) shall be placed in a closed, but unsealed, petri dish and placed in a weighing chamber for stabilization. At the end of the stabilization period, each filter (pair) shall be weighed and the tare weight shall be recorded. The filter (pair) shall then be stored in a closed petri dish or filter holder until needed for testing. If the filter (pair) is not used within eight hours of its removal from the weighing chamber, it shall be reweighed before use.
Annex 4A
Installation of the measuring equipment
The instrumentation and sample probes shall be installed as required. When using a full flow dilution system for exhaust gas dilution, the tailpipe shall be connected to the system.
Starting the dilution system and engine
The dilution system and the engine shall be started and warmed up until all temperatures and pressures have stabilized at full load and rated speed (paragraph 3.6.2.).
Adjustment of the dilution ratio
The particulate sampling system shall be started and running on bypass for the single filter method (optional for the multiple filter method). The particulate background level of the dilution air may be determined by passing dilution air through the particulate filters. If filtered dilution air is used, one measurement may be done at any time prior to, during, or after the test. If the dilution air is not filtered, the measurement shall be done on one sample taken for the duration of the test. The dilution air shall be set to obtain a filter face temperature between 315 K (42 °C) and 325 K (52 °C) at each mode. The total dilution ratio shall not be less than four. Note: For power bands up to and including K using discrete mode cycles the filter temperature may be kept at or below the maximum temperature of 325 K (52 °C) instead of respecting the temperature range of 42 °C to 52 °C. For the single and multiple filter methods, the sample mass flow rate through the filter shall be maintained at a constant proportion of the dilute exhaust mass flow rate for full flow systems for all modes. This mass ratio shall be within ±5 per cent with respect to the averaged value of the mode, except for the first 10 s of each mode for systems without bypass capability. For partial flow dilution systems with single filter method, the mass flow rate through the filter shall be constant within ±5 per cent with respect to the averaged value of the mode, except for the first 10 s of each mode for systems without bypass capability. For CO2 or NOx concentration controlled systems, the CO2 or NOx content of the dilution air shall be measured at the beginning and at the end of each test. The pre and post test background CO2 or NOx concentration measurements of the dilution air shall be within 100 ppm or 5 ppm of each other, respectively. When using a dilute exhaust gas analysis system, the relevant background concentrations shall be determined by sampling dilution air into a sampling bag over the complete test sequence. Continuous (non-bag) background concentration may be taken at the minimum of three points, at the beginning, at the end, and a point near the middle of the cycle and averaged. At the manufacturer's request background measurements may be omitted.
Checking the analysers
The emission analysers shall be set at zero and spanned.
Annex 4A
Test cycle
Machinery specification according to paragraphs 1.1. to 1.3.:
Specification A For engines covered by paragraphs 1.1. and 1.2. of this Regulation, the discrete 8-mode cycle 1 of Annex 5, sub-paragraph (a) of paragraph 1.1. shall be followed in dynamometer operation on the test engine. As an option, the corresponding ramped modal 9-mode cycle of Annex 5, sub- paragraph (a) of paragraph 1.2. may be used. In this case, the cycle shall be run in accordance with Annex 4B, paragraph 7.8.2. instead of following the procedures in paragraphs 3.7.2. to 3.7.6.
Specification B
For engines covered by paragraph 1.3. of this Regulation, the discrete 5-mode cycle 2 of Annex 5, sub-paragraph (b) of paragraph 1.1. shall be followed in dynamometer operation on the test engine. As an option, the ramped modal 5-mode cycle of Annex 5, sub-paragraph (b) of paragraph 1.2. may be used. In this case, the cycle shall be run in accordance with Annex 4B, paragraph 7.8.2. instead of following the procedures in paragraphs 3.7.2. to 3.7.6. The load figures are percentage values of the torque corresponding to the prime power rating defined as the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals and under the stated ambient conditions, the maintenance being carried out as prescribed by the manufacturer.
Conditioning of the engine
Warming up of the engine and the system shall be at maximum speed and torque in order to stabilize the engine parameters according to the recommendations of the manufacturer. Note: The conditioning period should also prevent the influence of deposits from a former test in the exhaust system. There is also a required period of stabilization between test points which has been included to minimize point to point influences.
Test sequence
The test sequence shall be started. The test shall be performed in the order of the mode numbers as set out above for the test cycles. During each mode of the given test cycle after the initial transition period, the specified speed shall be held to within ±1 per cent of rated speed or ±3 min-1, whichever is greater, except for low idle which shall be within the tolerances declared by the manufacturer. The specified torque shall be held so that the average over the period during which the measurements are being taken is within ±2 per cent of the maximum torque at the test speed.
Identical with C1 cycle as described in paragraph 8.3.1.1. of ISO 8178-4:2008. Identical with D2 cycle as described in paragraph 8.4.1. of ISO 8178-4: 2008.
Annex 4A
For each measuring point a minimum time of ten minutes is necessary. If for the testing of an engine, longer sampling times are required for reasons of obtaining sufficient particulate mass on the measuring filter the test mode period can be extended as necessary. The mode length shall be recorded and reported. The gaseous exhaust emission concentration values shall be measured and recorded during the last three minutes of the mode. The particulate sampling and the gaseous emission measurement should not commence before engine stabilization, as defined by the manufacturer, has been achieved and their completion shall be coincident. The fuel temperature shall be measured at the inlet to the fuel injection pump or as specified by the manufacturer, and the location of measurement recorded.
Analyser response
The output of the analysers shall be recorded on a strip chart recorder or measured with an equivalent data acquisition system with the exhaust gas flowing through the analysers at least during the last three minutes of each mode. If bag sampling is applied for the diluted CO and CO2 measurement (see Annex 4A, Appendix 1, paragraph 1.4.4.), a sample shall be bagged during the last three minutes of each mode, and the bag sample analysed and recorded.
Particulate sampling
The particulate sampling can be done either with the single filter method or with the multiple filter method (Annex 4A, Appendix 1, paragraph 1.5.). Since the results of the methods may differ slightly, the method used shall be declared with the results. For the single filter method the modal weighing factors specified in the test cycle procedure shall be taken into account during sampling by adjusting sample flow rate and/or sampling time, accordingly. Sampling shall be conducted as late as possible within each mode. The sampling time per mode shall be at least 20 s for the single filter method and at least 60 s for the multifilter method. For systems without bypass capability, the sampling time per mode shall be at least 60 s for single and multiple filter methods.
Engine conditions
The engine speed and load, intake air temperature, fuel flow and air or exhaust gas flow shall be measured for each mode once the engine has been stabilized. If the measurement of the exhaust gas flow or the measurement of combustion air and fuel consumption is not possible, it can be calculated using the carbon and oxygen balance method (see Annex 4A, Appendix 1, paragraph 1.2.3.). Any additional data required for calculation shall be recorded (see Annex 4A, Appendix 3, paragraphs 1.1. and 1.2.).
Annex 4A
Re-checking the analysers
After the emission test a zero gas and the same span gas will be used for re- checking. The test will be considered acceptable if the difference between the two measuring results is less than 2 per cent.
4.Test run (NRTC test)
Introduction
The non-road transient cycle (NRTC) is listed in Annex 5 as a second-by- second sequence of normalized speed and torque values applicable to all diesel engines covered by this Regulation. In order to perform the test on an engine test cell, the normalized values shall be converted to the actual values for the individual engine under test, based on the engine mapping curve. This conversion is referred to as denormalization, and the test cycle developed is referred to as the reference cycle of the engine to be tested. With these reference speed and torque values, the cycle shall be run on the test cell, and the feedback speed and torque values recorded. In order to validate the test run, a regression analysis between reference and feedback speed and torque values shall be conducted upon completion of the test.
The use of defeat devices or irrational control or irrational emission control strategies shall be prohibited
Engine mapping procedure
When generating the NRTC on the test cell, the engine shall be mapped before running the test cycle to determine the speed vs. torque curve.
Determination of the mapping speed range
The minimum and maximum mapping speeds are defined as follows:
Minimum mapping = idle speed speed
Maximum mapping = nhi x 1.02 or speed where full load torque drops off to zero, speed whichever is lower (where nhi is the high speed, defined as the highest engine speed where 70 per cent of the rated power is delivered).
Engine mapping curve
The engine shall be warmed up at maximum power in order to stabilize the engine parameters according to the recommendation of the manufacturer and good engineering practice. When the engine is stabilized, the engine mapping shall be performed according to the following procedures.
Transient map
(a) The engine shall be unloaded and operated at idle speed.
(b) The engine shall be operated at full load setting of the injection pump at minimum mapping speed.
(c) The engine speed shall be increased at an average rate of 8 ± 1 min-1/s from minimum to maximum mapping speed. Engine speed and torque points shall be recorded at a sample rate of at least one point per second.
Annex 4A
Step map
(a) The engine shall be unloaded and operated at idle speed.
(b) The engine shall be operated at full load setting of the injection pump at minimum mapping speed.
(c) While maintaining full load, the minimum mapping speed shall be maintained for at least 15 s, and the average torque during the last 5 s shall be recorded. The maximum torque curve from minimum to maximum mapping speed shall be determined in no greater than 100 ± 20 min-1 speed increments. Each test point shall be held for at least 15 s, and the average torque during the last 5 s shall be recorded.
Mapping curve generation
All data points recorded under paragraph 4.2.2. shall be connected using linear interpolation between points. The resulting torque curve is the mapping curve and shall be used to convert the normalized torque values of the engine dynamometer schedule of Annex 5 into actual torque values for the test cycle, as described in paragraph 4.3.3.
Alternate mapping
If a manufacturer believes that the above mapping techniques are unsafe or unrepresentative for any given engine, alternate mapping techniques may be used. These alternate techniques shall satisfy the intent of the specified mapping procedures to determine the maximum available torque at all engine speeds achieved during the test cycles. Deviations from the mapping techniques specified in this paragraph for reasons of safety or representativeness shall be approved by the parties involved along with the justification for their use. In no case, however, shall the torque curve be run by descending engine speeds for governed or turbocharged engines.
Replicate tests
An engine need not be mapped before each and every test cycle. An engine shall be remapped prior to a test cycle if:
(a) An unreasonable amount of time has transpired since the last map, as determined by engineering judgement, or,
(b) Physical changes or recalibrations have been made to the engine, which may potentially affect engine performance.
Generation of the reference test cycle
Reference speed
The reference speed (nref) corresponds to the 100 per cent normalized speed values specified in the engine dynamometer schedule of Annex 5. The actual engine cycle resulting from denormalization to the reference speed depends largely on selection of the proper reference speed. The reference speed shall be determined by the following formula: nref = low speed + 0.95 (high speed – low speed) (The high speed is the highest engine speed where 70 per cent of the rated power is delivered, while the low speed is the lowest engine speed where 50 per cent of the rated power is delivered).
Annex 4A
If the measured reference speed is within ±3 per cent of the reference speed as declared by the manufacturer, the declared reference speed may be used for the emissions test. If the tolerance is exceeded, the measured reference speed shall be used for the emissions test. (This is consistent with the ISO 8178-11:2006 standard.)
Denormalization of engine speed
The speed shall be denormalized using the following equation: % speed ActualSpeed = ⋅ (referencespeed − idlespeed ) + idlespeed
Denormalization of engine torque
The torque values in the engine dynamometer schedule of Annex 5 are normalized to the maximum torque at the respective speed. The torque values of the reference cycle shall be denormalized, using the mapping curve determined according to paragraph 4.2.2., as follows: %torque Actualtorque = ⋅ max.torque for the respective actual speed as determined in paragraph 4.3.2.
Example of denormalization procedure
As an example, the following test point shall be denormalized: % speed = 43 per cent % torque = 82 per cent Given the following values: referencespeed = 2,200 min-1 idlespeed = 600 min-1 results in ActualSpeed = ⋅ (2200 − 600) + 600 = 1288 min −1 With the maximum torque of 700 Nm observed from the mapping curve at 1,288 min-1 Actualtorque = ⋅ 700 = 574Nm
Dynamometer
When using a load cell, the torque signal shall be transferred to the engine axis and the inertia of the dyno shall be considered. The actual engine torque is the torque read on the load cell plus the moment of inertia of the brake multiplied by the angular acceleration. The control system has to perform this calculation in real time.
If the engine is tested with an eddy-current dynamometer, it is recommended
T − 2 ⋅ π ⋅ n& ⋅ Θ that the number of points, where the difference sp sp D is smaller than –5 per cent of the peak torque, does not exceed 30 (where Tsp is
Annex 4A
n& sp the demanded torque, is the derivative of the engine speed, ΘD is the rotational inertia of the eddy-current dynamometer).
Emissions test run
The following flow chart outlines the test sequence:
Engine preparation, pre-test measurements and calibrations
NRTC
Generation engine map (max torque curve) Generate reference test cycle
Run one or more practice cycle as necessary to check engine/test cell/emissions systems
Natural or forced cool down
Ready all systems for sampling (analyzer calibration included) & data collection
Cold start cycle exhaust emission phase
Hot soak
Hot start cycle exhaust emission phase
One or more practice cycles may be run as necessary to check engine, test cell and emissions systems before the measurement cycle.
Preparation of the sampling filters
At least one hour before the test, each filter shall be placed in a petri dish, which is protected against dust contamination and allows air exchange, and placed in a weighing chamber for stabilization. At the end of the stabilization period, each filter shall be weighed and the weight shall be recorded. The filter shall then be stored in a closed petri dish or sealed filter holder until needed for testing. The filter shall be used within eight hours of its removal from the weighing chamber. The tare weight shall be recorded.
Annex 4A
Installation of the measuring equipment
The instrumentation and sample probes shall be installed as required. The tailpipe shall be connected to the full-flow dilution system, if used.
Starting the dilution system
The dilution system shall be started. The total diluted exhaust gas flow of a full-flow dilution system or the diluted exhaust gas flow through a partial flow dilution system shall be set to eliminate water condensation in the system, and to obtain a filter face temperature between 315 K (42 °C) and 325 K (52 °C).
Starting the particulate sampling system
The particulate sampling system shall be started and run on by-pass. The particulate background level of the dilution air may be determined by sampling the dilution air prior to entrance of the exhaust into the dilution tunnel. It is preferred that background particulate sample be collected during the transient cycle if another PM sampling system is available. Otherwise, the PM sampling system used to collect transient cycle PM can be used. If filtered dilution air is used, one measurement may be done prior to or after the test. If the dilution air is not filtered, measurements should be carried out prior to the beginning and after the end of the cycle and the values averaged.
Checking the analysers
The emission analysers shall be set at zero and spanned. If sample bags are used, they shall be evacuated.
Cool-down requirements
A natural or forced cool-down procedure may be applied. For forced cool- down, good engineering judgment shall be used to set up systems to send cooling air across the engine, to send cool oil through the engine lubrication system, to remove heat from the coolant through the engine cooling system, and to remove heat from an exhaust after-treatment system. In the case of a forced after-treatment cool down, cooling air shall not be applied until the after- treatment system has cooled below its catalytic activation temperature. Any cooling procedure that results in unrepresentative emissions is not permitted. The cold start cycle exhaust emission test may begin after a cool-down only when the engine oil, coolant and after-treatment temperatures are stabilized between 20 °C and 30 °C for a minimum of fifteen minutes.
Cycle run
Cold start cycle
The test sequence shall commence with the cold start cycle at the completion of the cool-down when all the requirements specified in paragraph 4.5.6. are met. The engine shall be started according to the starting procedure recommended by the manufacturer in the owner's manual, using either a production starter motor or the dynamometer.
Annex 4A
As soon as it is determined that the engine is started, start a "free idle" timer. Allow the engine to idle freely with no-load for 23 ± 1 s. Begin the transient engine cycle such that the first non-idle record of the cycle occurs at 23 ± 1 s. The free idle time is included in the 23 ± 1 s. The test shall be performed according to the reference cycle as set out in Annex 5. Engine speed and torque command set points shall be issued at 5 Hz (10 Hz recommended) or greater. The set points shall be calculated by linear interpolation between the 1 Hz set points of the reference cycle. Feedback engine speed and torque shall be recorded at least once every second during the test cycle, and the signals may be electronically filtered.
Analyser response
At the start of the engine the measuring equipment shall be started, simultaneously:
(a) Start collecting or analysing dilution air, if a full flow dilution system is used;
(b) Start collecting or analysing raw or diluted exhaust gas, depending on the method used;
(c) Start measuring the amount of diluted exhaust gas and the required temperatures and pressures;
(d) Start recording the exhaust gas mass flow rate, if raw exhaust gas analysis is used;
(e) Start recording the feedback data of speed and torque of the dynamometer. If raw exhaust measurement is used, the emission concentrations (HC, CO and NOx) and the exhaust gas mass flow rate shall be measured continuously and stored with at least 2 Hz on a computer system. All other data may be recorded with a sample rate of at least 1 Hz. For analogue analysers the response shall be recorded, and the calibration data may be applied online or offline during the data evaluation. If a full flow dilution system is used, HC and NOx shall be measured continuously in the dilution tunnel with a frequency of at least 2 Hz. The average concentrations shall be determined by integrating the analyser signals over the test cycle. The system response time shall be no greater than 20 s, and shall be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO and CO2 shall be determined by integration or by analysing the concentrations in the sample bag collected over the cycle. The concentrations of the gaseous pollutants in the dilution air shall be determined by integration or by collection in the background bag. All other parameters that need to be measured shall be recorded with a minimum of one measurement per second (1 Hz).
Particulate sampling
At the start of the engine the particulate sampling system shall be switched from by-pass to collecting particulates. If a partial flow dilution system is used, the sample pump(s) shall be adjusted so that the flow rate through the particulate sample probe or transfer tube is maintained proportional to the exhaust mass flow rate.
Annex 4A
If a full flow dilution system is used, the sample pump(s) shall be adjusted so that the flow rate through the particulate sample probe or transfer tube is maintained at a value within ±5 per cent of the set flow rate. If flow compensation (i.e. proportional control of sample flow) is used, it shall be demonstrated that the ratio of main tunnel flow to particulate sample flow does not change by more than ±5 per cent of its set value (except for the first 10 s of sampling). Note: For double dilution operation, sample flow is the net difference between the flow rate through the sample filters and the secondary dilution airflow rate. The average temperature and pressure at the gas meter(s) or flow instrumentation inlet shall be recorded. If the set flow rate cannot be maintained over the complete cycle (within ±5 per cent) because of high particulate loading on the filter, the test shall be voided. The test shall be rerun using a lower flow rate and/or a larger diameter filter.
Engine stalling during the cold start test cycle
If the engine stalls anywhere during the cold start test cycle, the engine shall be preconditioned, then the cool-down procedure repeated; finally the engine shall be restarted, and the test repeated. If a malfunction occurs in any of the required test equipment during the test cycle, the test shall be voided.
Operations after cold start cycle
At the completion of the cold start cycle of the test, the measurement of the exhaust gas mass flow rate, the diluted exhaust gas volume, the gas flow into the collecting bags and the particulate sample pump shall be stopped. For an integrating analyser system, sampling shall continue until system response times have elapsed. The concentrations of the collecting bags, if used, shall be analysed as soon as possible and in any case not later than 20 minutes after the end of the test cycle. After the emission test, a zero gas and the same span gas shall be used for rechecking the analysers. The test will be considered acceptable if the difference between the pre-test and post-test results is less than 2 per cent of the span gas value. The particulate filters shall be returned to the weighing chamber no later than one hour after completion of the test. They shall be conditioned in a petri dish, which is protected against dust contamination and allows air exchange, for at least one hour, and then weighed. The gross weight of the filters shall be recorded.
Hot soak
Immediately after the engine is turned off, the engine cooling fan(s) shall be turned off if used, as well as the CVS blower (or disconnect the exhaust system from the CVS), if used. Allow the engine to soak for 20 ± 1 minutes. Prepare the engine and dynamometer for the hot start test. Connect evacuated sample collection bags to the dilute exhaust and dilution air sample collection systems. Start the CVS (if used or not already on) or connect the exhaust system to the CVS (if disconnected). Start the sample pumps (except the particulate sample pump(s), the engine cooling fan(s) and the data collection system.
Annex 4A
The heat exchanger of the constant volume sampler (if used) and the heated components of any continuous sampling system(s) (if applicable) shall be preheated to their designated operating temperatures before the test begins. Adjust the sample flow rates to the desired flow rate and set the CVS gas flow measuring devices to zero. Carefully install a clean particulate filter in each of the filter holders and install assembled filter holders in the sample flow line.
Hot start cycle
As soon as it is determined that the engine is started, start a "free idle" timer. Allow the engine to idle freely with no-load for 23 ± 1 s. Begin the transient engine cycle such that the first non-idle record of the cycle occurs at 23 ± 1 s. The free idle time is included in the 23 ± 1 s. The test shall be performed according to the reference cycle as set out in Annex
Engine speed and torque command set points shall be issued at 5 Hz (10 Hz recommended) or greater. The set points shall be calculated by linear interpolation between the 1 Hz set points of the reference cycle. Feedback engine speed and torque shall be recorded at least once every second during the test cycle, and the signals may be electronically filtered. The procedure described in previous paragraphs 4.5.7.2. and 4.5.7.3. shall then be repeated.
Engine stalling during the hot start cycle
If the engine stalls anywhere during the hot start cycle, the engine may be shut off and re-soaked for 20 minutes. The hot start cycle may then be rerun. Only one hot re-soak and hot start cycle restart is permitted.
Operations after hot start cycle
At the completion of the hot start cycle, the measurement of the exhaust gas mass flow rate, the diluted exhaust gas volume, the gas flow into the collecting bags and the particulate sample pump shall be stopped. For an integrating analyser system, sampling shall continue until system response times have elapsed. The concentrations of the collecting bags, if used, shall be analysed as soon as possible and in any case not later than 20 minutes after the end of the test cycle. After the emission test, a zero gas and the same span gas shall be used for re- checking the analysers. The test will be considered acceptable if the difference between the pre-test and post-test results is less than 2 per cent of the span gas value. The particulate filters shall be returned to the weighing chamber no later than one hour after completion of the test. They shall be conditioned in a petri dish, which is protected against dust contamination and allows air exchange, for at least one hour, and then weighed. The gross weight of the filters shall be recorded.
Verification of the test run
Data shift
To minimize the biasing effect of the time lag between the feedback and reference cycle values, the entire engine speed and torque feedback signal sequence may be advanced or delayed in time with respect to the reference speed and torque sequence. If the feedback signals are shifted, both speed and torque shall be shifted by the same amount in the same direction. Annex 4A
Calculation of the cycle work
The actual cycle work Wact (kWh) shall be calculated using each pair of engine feedback speed and torque values recorded. The actual cycle work Wact is used for comparison to the reference cycle work Wref and for calculating the brake specific emissions. The same methodology shall be used for integrating both reference and actual engine power. If values are to be determined between adjacent references or adjacent measured values, linear interpolation shall be used. In integrating the reference and actual cycle work, all negative torque values shall be set equal to zero and included. If integration is performed at a frequency of less than 5 Hz, and if, during a given time segment, the torque value changes from positive to negative or negative to positive, the negative portion shall be computed and set equal to zero. The positive portion shall be included in the integrated value. Wact shall be between –15 per cent and +5 per cent of Wref.
Validation statistics of the test cycle
Linear regressions of the feedback values on the reference values shall be performed for speed, torque and power. This shall be done after any feedback data shift has occurred, if this option is selected. The method of least squares shall be used, with the best fit equation having the form: y = mx + b where: y = feedback (actual) value of speed (min-1), torque (N·m), or power (kW) m = slope of the regression line x = reference value of speed (min-1), torque (N·m), or power (kW) b = y intercept of the regression line The standard error of estimate (SE) of y on x and the coefficient of determination (r2) shall be calculated for each regression line. It is recommended that this analysis be performed at 1 Hz. For a test to be considered valid, the criteria of Table 1 shall be met.
Regression line tolerances
Speed Torque Power
Standard error of estimate (SEE) max 13 % of power map max 8 % of power map
of y on x max 100 min-1 maximum engine torque maximum engine power
Slope of the regression line, m 0.95 to 1.03 0.83 – 1.03 0.89 – 1.03
Coefficient of determination, r2 min 0.9700 min 0.8800 min 0.9100
±20 Nm or ±2 % of max ±4 kW or ±2 % of max
y intercept of the regression line, torque, whichever is power, whichever is
b ±50 min-1 greater greater
Annex 4A
For regression purposes only, point deletions are permitted where noted inbefore doing the regression calculation. However, those points shall not
be deleted for the calculation of cycle work and emissions. An idle point is defined as a point having a normalized reference torque of 0 per cent and a normalized reference speed of 0 per cent. Point deletion may be applied to the whole or to any part of the cycle. Permitted point deletions from regression analysis (points to which the point deletion is applied have to be specified) Condition Speed and/or torque and/or power points which may be deleted with reference to the conditions listed in the left column First 24 (±1) s and last 25 s Speed, torque and power Wide open throttle, and torque feedback < 95 % torque Torque and/or power reference Wide open throttle, and speed feedback < 95 % speed Speed and/or power reference Closed throttle, speed feedback > idle speed + 50 min- Torque and/or power , and torque feedback > 105 % torque reference Closed throttle, speed feedback ≤ idle speed + 50 min- Speed and/or power , and torque feedback = Manufacturer defined/measured idle torque ±2 % of max torque Closed throttle and speed feedback > 105 % speed Speed and/or power reference Annex 4A - Appendix 1 Annex 4A - Appendix 1 Measurement and sampling procedures (NRSC, NRTC)
1.Measurement and sampling procedures (NRSC test)
Gaseous and particulate components emitted by the engine submitted for testing shall be measured by the methods described in Annex 4A, Appendix 4. The methods of Annex 4A, Appendix 4 describe the recommended analytical systems for the gaseous emissions (paragraph 1.1.) and the recommended particulate dilution and sampling systems (paragraph 1.2.). At the request of the manufacturer and with the agreement of the approval authority the methods described in Annex 4B, paragraph 9. may be used as an alternative to those in paragraph 1. of this appendix.
Dynamometer specification
An engine dynamometer with adequate characteristics to perform the test cycle described in Annex 4A, paragraph 3.7.1. shall be used. The instrumentation for torque and speed measurement shall allow the measurement of the power within the given limits. Additional calculations may be necessary. The accuracy of the measuring equipment shall be such that the maximum tolerances of the figures given in paragraph 1.3. are not exceeded.
Exhaust gas flow
The exhaust gas flow shall be determined by one of the methods mentioned in paragraphs 1.2.1. to 1.2.4.
Direct measurement method
Direct measurement of the exhaust flow by flow nozzle or equivalent metering system (for detail see ISO 5167:2000). Note: Direct gaseous flow measurement is a difficult task. Precautions shall be taken to avoid measurement errors that will impact emission value errors.
Air and fuel measurement method
Measurement of the airflow and the fuel flow. Air flow-meters and fuel flow-meters with the accuracy defined in paragraph 1.3. shall be used. The calculation of the exhaust gas flow is as follows: GEXHW = GAIRW + GFUEL (for wet exhaust mass)
Carbon balance method
Exhaust mass calculation from fuel consumption and exhaust gas concentrations using the carbon balance method (Annex 4A, Appendix 3).
Tracer measurement method
This method involves measurement of the concentration of a tracer gas in the exhaust. A known amount of an inert gas (e.g. pure helium) shall be injected
Annex 4A - Appendix 1
into the exhaust gas flow as a tracer. The gas is mixed and diluted by the exhaust gas, but shall not react in the exhaust pipe. The concentration of the gas shall then be measured in the exhaust gas sample. In order to ensure complete mixing of the tracer gas, the exhaust gas sampling probe shall be located at least 1 m or 30 times the diameter of the exhaust pipe, whichever is larger, downstream of the tracer gas injection point. The sampling probe may be located closer to the injection point if complete mixing is verified by comparing the tracer gas concentration with the reference concentration when the tracer gas is injected upstream of the engine. The tracer gas flow rate shall be set so that the tracer gas concentration at engine idle speed after mixing becomes lower than the full scale of the trace gas analyser. The calculation of the exhaust gas flow is as follows: GT ⋅ ρ EXH GEXHW = 60 ⋅ (concmix − conca ) where: GEXHW = instantaneous exhaust mass flow (kg/s) GT = tracer gas flow (cm3/min) concmix = instantaneous concentration of the tracer gas after mixing, (ppm) ρEXH = density of the exhaust gas (kg/m3) conca = background concentration of the tracer gas in the intake air (ppm) The background concentration of the tracer gas (conca) may be determined by averaging the background concentration measured immediately before and after the test run. When the background concentration is less than 1 per cent of the concentration of the tracer gas after mixing (concmix.) at maximum exhaust flow, the background concentration may be neglected. The total system shall meet the accuracy specifications for the exhaust gas flow and shall be calibrated according to Appendix 2, paragraph 1.11.2.
Air flow and air to fuel ratio measurement method
This method involves exhaust mass calculation from the air flow and the air to fuel ratio. The calculation of the instantaneous exhaust gas mass flow is as follows: GEXHW = GAIRW ⋅ (1 + ) A / Fst ⋅ λ with A / Fst = 14.5
Annex 4A - Appendix 1
⎛ 2 ⋅ concCO ⋅10−4 ⎞ 1 − ⎛ concCO ⋅10−4 ⎞ ⎜ 3.5 ⋅ conc ⎟ ( )
C O ⎜100 − − concHC ⋅10−4 ⎟ + ⎜ 0.45 ⋅ ⎟ ⋅ conc + concCO ⋅10−4
C O −4 ⎝ 2 ⎠ ⎜ concCO ⋅10 ⎟ ⎜ 1+ ⎟ 3.5 ⋅ conc
C O λ= ⎝ ⎠ 6.9078 ⋅ (conc + concCO ⋅10−4 + concHC ⋅10−4 )
C O where: A/Fst = stoichiometric air/fuel ratio (kg/kg) λ = relative air/fuel ratio concCO2 = dry CO2 concentration (%) concCO = dry CO concentration (ppm) concHC = HC concentration (ppm) Note: The calculation refers to a diesel fuel with a H/C ratio equal to paragraph 1.8. The air flow-meter shall meet the accuracy specifications in Table 3, the CO2 analyser used shall meet the specifications of paragraph 1.4.1., and the total system shall meet the accuracy specifications for the exhaust gas flow. Optionally, air to fuel ratio measurement equipment, such as a zirconia type sensor, may be used for the measurement of the relative air to fuel ratio in accordance with the specifications of paragraph 1.4.4.
Total dilute exhaust gas flow
When using a full flow dilution system, the total flow of the dilute exhaust (GTOTW) shall be measured with a PDP or CFV or SSV (Annex 4A, Appendix 4, paragraph 1.2.1.2.). The accuracy shall conform to the provisions of Annex 4A, Appendix 2, paragraph 2.2.
Accuracy
The calibration of all measurement instruments shall be traceable to national or international standards and comply with the requirements listed in Table 3.
Accuracy of measuring instruments
No. Measuring instrument Accuracy
1 Engine speed ±2 % of reading or ±1 % of engine's max. value whichever
is larger
2 Torque ±2 % of reading or ±1 % of engine's max. value whichever
is larger
3 Fuel consumption ±2 % of engine's max. value
4 Air consumption ±2 % of reading or ±1 % of engine's max. value whichever
is larger
5 Exhaust gas flow ±2.5 % of reading or ±1.5 % of engine's max. value
whichever is larger
Annex 4A - Appendix 1
No. Measuring instrument Accuracy
6 Temperatures ≤ 600 K ±2 K absolute
7 Temperatures > 600 K ±1 % of reading
8 Exhaust gas pressure ±0.2 kPa absolute
9 Intake air depression ±0.05 kPa absolute
10 Atmospheric pressure ±0.1 kPa absolute
11 Other pressures ±0.1 kPa absolute
12 Absolute humidity ±5 % of reading
13 Dilution air flow ±2 % of reading
14 Diluted exhaust gas ±2 % of reading
flowDetermination of the gaseous components
General analyser specifications
The analysers shall have a measuring range appropriate for the accuracy required to measure the concentrations of the exhaust gas components (paragraph 1.4.1.1.). It is recommended that the analysers be operated in such a way that the measured concentration falls between 15 per cent and 100 per cent of full scale. If the full scale value is 155 ppm (or ppm C) or less or if read-out systems (computers, data loggers) that provide sufficient accuracy and resolution below 15 per cent of full scale are used, concentrations below 15 per cent of full scale are also acceptable. In this case, additional calibrations are to be made to ensure the accuracy of the calibration curves – Annex 4A, Appendix 2, paragraph 1.5.5.2. The electromagnetic compatibility (EMC) of the equipment shall be on a level as to minimize additional errors.
Measurement error
The analyser shall not deviate from the nominal calibration point by more than ±2 per cent of the reading or ±0.3 per cent of full scale, whichever is larger. Note: For the purpose of this standard, accuracy is defined as the deviation of the analyser reading from the nominal calibration values using a calibration gas (≡ true value)
Repeatability
The repeatability, defined as 2.5 times the standard deviation of ten repetitive responses to a given calibration or span gas, shall be no greater than ±1 per cent of full scale concentration for each range used above 155 ppm (or ppm C) or ±2 per cent of each range used below 155 ppm (or ppm C).
Annex 4A - Appendix 1
Noise
The analyser peak-to-peak response to zero and calibration or span gases over any ten second period shall not exceed 2 per cent of full scale on all ranges used.
Zero drift
The zero drift during a one-hour period shall be less than 2 per cent of full scale on the lowest range used. The zero response is defined as the mean response, including noise, to a zero gas during a 30 s time interval.
Span drift
The span drift during a one-hour period shall be less than 2 per cent of full scale on the lowest range used. Span is defined as the difference between the span response and the zero response. The span response is defined as the mean response, including noise, to a span gas during a 30 s time interval.
Gas drying
The optional gas drying device shall have a minimal effect on the concentration of the measured gases. Chemical dryers are not an acceptable method of removing water from the sample.
Analysers
Paragraphs 1.4.3.1. to 1.4.3.5. of this appendix describe the measurement principles to be used. A detailed description of the measurement systems is given in Annex 4A, Appendix 4. The gases to be measured shall be analysed with the following instruments. For non-linear analysers, the use of linearizing circuits is permitted.
Carbon monoxide (CO) analysis
The carbon monoxide analyser shall be of the non-dispersive infra-red (NDIR) absorption type.
Carbon dioxide (CO2) analysis
The carbon dioxide analyser shall be of the non-dispersive infra-red (NDIR) absorption type.
Hydrocarbon (HC) analysis
The hydrocarbon analyser shall be of the heated flame ionization detector (HFID) type with detector, valves, pipework, etc, heated so as to maintain a gas temperature of 463 K (190 °C) ± 10 K.
Oxides of nitrogen (NOx) analysis
The oxides of nitrogen analyser shall be of the chemiluminescent detector (CLD) or heated chemiluminescent detector (HCLD) type with a NO2/NO converter, if measured on a dry basis. If measured on a wet basis, a HCLD with converter maintained above 328 K (55 °C) shall be used, provided the water quench check (Annex 4A, Appendix 2, paragraph 1.9.2.2.) is satisfied. For both CLD and HCLD, the sampling path shall be maintained at a wall temperature of 328 K to 473 K (55 to 200 °C) up to the converter for dry measurement, and up to the analyser for wet measurement.
Annex 4A - Appendix 1
Air to fuel measurement
The air to fuel measurement equipment used to determine the exhaust gas flow as specified in paragraph 1.2.5. shall be a wide range air to fuel ratio sensor or lambda sensor of Zirconia type. The sensor shall be mounted directly on the exhaust pipe where the exhaust gas temperature is high enough to eliminate water condensation. The accuracy of the sensor with incorporated electronics shall be within: ±3 per cent of reading λ < 2 ±5 per cent of reading 2 ≤ λ < 5 ±10 per cent of reading 5 ≤ λ To fulfil the accuracy specified above, the sensor shall be calibrated as specified by the instrument manufacturer.
Sampling for gaseous emissions
The gaseous emissions sampling probes shall be fitted at least 0.5 m or three times the diameter of the exhaust pipe (whichever is the larger) upstream of the exit of the exhaust gas system as far as applicable and sufficiently close to the engine as to ensure an exhaust gas temperature of at least 343 K (70 °C) at the probe. In the case of a multi-cylinder engine with a branched exhaust manifold, the inlet of the probe shall be located sufficiently far downstream so as to ensure that the sample is representative of the average exhaust emissions from all cylinders. In multi-cylinder engines having distinct groups of manifolds, such as in a 'V'-engine configuration, it is permissible to acquire a sample from each group individually and calculate an average exhaust emission. Other methods which have been shown to correlate with the above methods may be used. For exhaust emissions calculation the total exhaust mass flow of the engine shall be used. When a full flow dilution system is used for the determination of the particulates, the gaseous emissions may also be determined in the diluted exhaust gas. The sampling probes shall be close to the particulate sampling probe in the dilution tunnel (Annex 4A, Appendix 4, paragraph 1.2.1.2., DT and paragraph 1.2.2., PSP). CO and CO2 may optionally be determined by sampling into a bag and subsequent measurement of the concentration in the sampling bag.
Determination of the particulates
The determination of the particulates requires a dilution system. Dilution may be accomplished by a partial flow dilution system or a full flow dilution system. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems, and maintain the temperature of the diluted exhaust gas between 315 K (42 °C) and 325 K (52 °C) immediately upstream of the filter holders. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. Dilution air pre-heating above the temperature limit of 303 K (30 °C) is recommended, if the ambient temperature is below 293 K (20 °C). However, the diluted air temperature shall not exceed 325 K (52 °C) prior to the introduction of the exhaust in the dilution tunnel.
Annex 4A - Appendix 1
Note: For power bands up to and including K using discrete mode cycles, the filter temperature may be kept at or below the maximum temperature of 325 K (52 °C) instead of respecting the temperature range of 42 to 52 °C. For a partial flow dilution system, the particulate sampling probe shall be fitted close to and upstream of the gaseous probe as defined in paragraph 4.4. and in accordance with Annex 4A, Appendix 4, paragraph 1.2.1.1.,
Particulate sampling filters
Filter specification
Fluorocarbon coated glass fibre filters or fluorocarbon based membrane filters are required for certification tests. For special applications different filter materials may be used. All filter types shall have a 0.3 μm DOP (di- octylphthalate) collection efficiency of at least 99 per cent at a gas face velocity between 35 and 100 cm/s. When performing correlation tests between laboratories or between a manufacturer and an approval authority, filters of identical quality shall be used.
Filter size
Particulate filters shall have a minimum diameter of 47 mm (37 mm stain diameter). Larger diameter filters are acceptable (paragraph 1.5.1.5.).
Primary and back-up filters
The diluted exhaust shall be sampled by a pair of filters placed in series (one primary and one back-up filter) during the test sequence. The back-up filter shall be located no more than 100 mm downstream of, and shall not be in contact with, the primary filter. The filters may be weighed separately or as a pair with the filters placed stain side to stain side.
Annex 4A - Appendix 1
Filter face velocity
A gas face velocity through the filter of 35 to 100 cm/s shall be achieved. The pressure drop increase between the beginning and the end of the test shall be no more than 25 kPa.
Filter loading
The recommended minimum filter loadings for the most common filter sizes are shown in the following table. For larger filter sizes, the minimum filter loading shall be 0.065 mg/1000 mm2 filter area.
Filter diameter Recommended stain diameter Recommended minimum loading
(mm) (mm) (mg)
47 37 0.11
70 60 0.25
90 80 0.41
110 100 0.62
For the multiple filter method, the recommended minimum filter loading for the sum of all filters shall be the product of the appropriate value above and the square root of the total number of modes.
Weighing chamber and analytical balance specifications
Weighing chamber conditions
The temperature of the chamber (or room) in which the particulate filters are conditioned and weighed shall be maintained to within 295 K (22 °C) ± 3 K during all filter conditioning and weighing. The humidity shall be maintained to a dew point of 282.5 (9.5 °C) ± 3 K and a relative humidity of 45 ± 8 per cent.
Reference filter weighing
The chamber (or room) environment shall be free of any ambient contaminants (such as dust) that would settle on the particulate filters during their stabilization. Disturbances to weighing room specifications as outlined in paragraph 1.5.2.1. will be allowed if the duration of the disturbances does not exceed 30 minutes. The weighing room should meet the required specifications prior to personnel entrance into the weighing room. At least two unused reference filters or reference filter pairs shall be weighed within four hours of, but preferably at the same time as the sample filter (pair) weighing. They shall be the same size and material as the sample filters. If the average weight of the reference filters (reference filter pairs) changes between sample filter weighing by more than 10 μg, then all sample filters shall be discarded and the emissions test repeated. If the weighing room stability criteria outlined in paragraph 1.5.2.1. is not met, but the reference filter (pair) weighing meet the above criteria, the engine manufacturer has the option of accepting the sample filter weights or voiding the tests, fixing the weighing room control system and re-running the test.
Annex 4A - Appendix 1
Analytical balance
The analytical balance used to determine the weights of all filters shall have a precision (standard deviation) of 2 μg and a resolution of 1 μg (1 digit = 1 μg) specified by the balance manufacturer.
Elimination of static electricity effects
To eliminate the effects of static electricity, the filters shall be neutralized prior to weighing, for example, by a Polonium neutralizer or a device of similar effect.
Additional specifications for particulate measurement
All parts of the dilution system and the sampling system from the exhaust pipe up to the filter holder, which are in contact with raw and diluted exhaust gas, shall be designed to minimize deposition or alteration of the particulates. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects.
2.Measurement and sampling procedures (NRTC test)
Introduction
Gaseous and particulate components emitted by the engine submitted for testing shall be measured by the methods of Annex 4A, Appendix 4. The methods of Annex 4A, Appendix 4 describe the recommended analytical systems for the gaseous emissions (paragraph 1.1.) and the recommended particulate dilution and sampling systems (paragraph 1.2.).
Dynamometer and test cell equipment
The following equipment shall be used for emission tests of engines on engine dynamometers:
Engine dynamometer
An engine dynamometer shall be used with adequate characteristics to perform the test cycle described in Appendix 4 to this Annex. The instrumentation for torque and speed measurement shall allow the measurement of the power within the given limits. Additional calculations may be necessary. The accuracy of the measuring equipment shall be such that the maximum tolerances of the figures given in Table 4 are not exceeded.
Other instruments
Measuring instruments for fuel consumption, air consumption, temperature of coolant and lubricant, exhaust gas pressure and intake manifold depression, exhaust gas temperature, air intake temperature, atmospheric pressure, humidity and fuel temperature shall be used, as required. These instruments shall satisfy the requirements given in Table 4:
Annex 4A - Appendix 1
Accuracy of measuring instruments
No. Measuring instrument Accuracy 1 Engine speed ±2 % of reading or ±1 % of engine's max. value, whichever is larger 2 Torque ±2 % of reading or ±1 % of engine's max. value, whichever is larger 3 Fuel consumption ±2 % of engine's max. value 4 Air consumption ±2 % of reading or ±1 % of engine's max. value, whichever is larger 5 Exhaust gas flow ±2.5 % of reading or ±1.5 % of engine's max. value, whichever is larger 6 Temperatures ≤ 600 K ±2 K absolute 7 Temperatures > 600 K ±1 % of reading 8 Exhaust gas pressure ±0.2 kPa absolute 9 Intake air depression ±0.05 kPa absolute 10 Atmospheric pressure ±0.1 kPa absolute 11 Other pressures ±0.1 kPa absolute 12 Absolute humidity ±5 % of reading 13 Dilution air flow ±2 % of reading 14 Diluted exhaust gas flow ±2 % of reading
Raw exhaust gas flow
For calculating the emissions in the raw exhaust gas and for controlling a partial flow dilution system, it is necessary to know the exhaust gas mass flow rate. For determining the exhaust mass flow rate, either of the methods described below may be used. For the purpose of emissions calculation, the response time of either method described below shall be equal to or less than the requirement for the analyser response time, as defined in Appendix 2, paragraph 1.11.1. For the purpose of controlling a partial flow dilution system, a faster response is required. For partial flow dilution systems with online control, a response time of ≤ 0.3 s is required. For partial flow dilution systems with look ahead control based on a pre-recorded test run, a response time of the exhaust flow measurement system of ≤ 5 s with a rise time of ≤ 1 s is required. The system response time shall be specified by the instrument manufacturer. The combined response time requirements for exhaust gas flow and partial flow dilution system are indicated in paragraph 2.4.
Annex 4A - Appendix 1
Direct measurement method Direct measurement of the instantaneous exhaust flow may be done by systems, such as:
(a) Pressure differential devices, like flow nozzle, (for details see ISO 5167: 2000);
(b) Ultrasonic flow-meter;
(c) Vortex flow-meter. Precautions shall be taken to avoid measurement errors, which will impact emission value errors. Such precautions include the careful installation of the device in the engine exhaust system according to the instrument manufacturers' recommendations and to good engineering practice. Especially, engine performance and emissions shall not be affected by the installation of the device. The flow-meters shall meet the accuracy specifications of Table 3. Air and fuel measurement method This involves measurement of the airflow and the fuel flow with suitable flow- meters. The calculation of the instantaneous exhaust gas flow is as follows: GEXHW = GAIRW + GFUEL (for wet exhaust mass) The flow-meters shall meet the accuracy specifications of Table 3, but shall also be accurate enough to also meet the accuracy specifications for the exhaust gas flow. Tracer measurement method This involves measurement of the concentration of a tracer gas in the exhaust. A known amount of an inert gas (e.g. pure helium) shall be injected into the exhaust gas flow as a tracer. The gas is mixed and diluted by the exhaust gas, but shall not react in the exhaust pipe. The concentration of the gas shall then be measured in the exhaust gas sample. In order to ensure complete mixing of the tracer gas, the exhaust gas sampling probe shall be located at least 1 m or 30 times the diameter of the exhaust pipe, whichever is larger, downstream of the tracer gas injection point. The sampling probe may be located closer to the injection point if complete mixing is verified by comparing the tracer gas concentration with the reference concentration when the tracer gas is injected upstream of the engine. The tracer gas flow rate shall be set so that the tracer gas concentration at engine idle speed after mixing becomes lower than the full scale of the trace gas analyser. The calculation of the exhaust gas flow is as follows: GEXHW = GAIRW ⋅ (1 + ) A / Fst ⋅ λ with A / Fst = 14.5
Annex 4A - Appendix 1
⎛ 2 ⋅ concCO ⋅10−4 ⎞ ⎜ 1− ⎟ ⎛ concCO ⋅10 −4 −4 ⎞ ⎜ 3.5 ⋅ conc ( )
C O 100 − − conc ⋅ 10 + 0.45 ⋅ ⎟ ⋅ conc + concCO ⋅10−4
C O ⎜ ⎟ ⎝ 2 HC ⎠ ⎜ concCO ⋅10−4 ⎟ ⎜ 1+ ⎟ 3.5 ⋅ conc
C O λ= ⎝ ⎠ 6.9078 ⋅ (conc + concCO ⋅10−4 + concHC ⋅10−4 )
C O where: A/Fst = stoichiometric air/fuel ratio (kg/kg) λ = relative air/fuel ratio concCO2 = dry CO2 concentration (%) concCO = dry CO concentration (ppm) concHC = HC concentration (ppm) Note: The calculation refers to a diesel fuel with a H/C ratio equal to 1.8. The air flow-meter shall meet the accuracy specifications in Table 3, the CO2 analyser used shall meet the specifications of paragraph 2.3.1., and the total system shall meet the accuracy specifications for the exhaust gas flow. Optionally, air to fuel ratio measurement equipment, such as a zirconia type sensor, may be used for the measurement of the excess air ratio in accordance with the specifications of paragraph 2.3.4.
Diluted exhaust gas flow
For calculation of the emissions in the diluted exhaust gas, it is necessary to know the diluted exhaust gas mass flow rate. The total diluted exhaust gas flow over the cycle (kg/test) shall be calculated from the measurement values over the cycle and the corresponding calibration data of the flow measurement device (V0 for PDP, KV for CFV, Cd for SSV): the corresponding methods described in Appendix 3, paragraph 2.2.1. shall be used. If the total sample mass of particulates and gaseous pollutants exceeds 0.5 per cent of the total CVS flow, the CVS flow shall be corrected or the particulate sample flow shall be returned to the CVS prior to the flow measuring device.
Determination of the gaseous components
General analyser specifications
The analysers shall have a measuring range appropriate for the accuracy required to measure the concentrations of the exhaust gas components (paragraph 1.4.1.1.). It is recommended that the analysers be operated in such a way that the measured concentration falls between 15 and 100 per cent of full scale. If the full scale value is 155 ppm (or ppm C) or less, or if read-out systems (computers, data loggers) that provide sufficient accuracy and resolution below 15 per cent of full scale are used, concentrations below 15 per cent of full scale are also acceptable. In this case, additional calibrations are to be made to ensure the accuracy of the calibration curves – Annex 4A, Appendix 2, paragraph 1.5.5.2.
Annex 4A - Appendix 1
The electromagnetic compatibility (EMC) of the equipment shall be of a level such as to minimize additional errors.
Measurement error
The analyser shall not deviate from the nominal calibration point by more than ±2 per cent of the reading or ±0.3 per cent of full scale, whichever is larger. Note: For the purpose of this standard, accuracy is defined as the deviation of the analyser reading from the nominal calibration values using a calibration gas (≡ true value).
Repeatability
The repeatability, defined as 2.5 times the standard deviation of 10 repetitive responses to a given calibration or span gas, shall be no greater than ±1 per cent of full scale concentration for each range used above 155 ppm (or ppm C) or ±2 per cent for each range used below 155 ppm (or ppm C).
Noise
The analyser peak-to-peak response to zero and calibration or span gases over any 10 s periods shall not exceed 2 per cent of full scale on all ranges used.
Zero drift
The zero drift during a one-hour period shall be less than 2 per cent of full scale on the lowest range used. The zero response is defined as the mean response, including noise, to a zero gas during a 30 s time interval.
Span drift
The span drift during a one-hour period shall be less than 2 per cent of full scale on the lowest range used. Span is defined as the difference between the span response and the zero response. The span response is defined as the mean response, including noise, to a span gas during a 30 s time interval.
Rise time
For raw exhaust gas analysis, the rise time of the analyser installed in the measurement system shall not exceed 2.5 s. Note: Only evaluating the response time of the analyser alone will not clearly define the suitability of the total system for transient testing. Volumes, and especially dead volumes, throughout the system will not only affect the transportation time from the probe to the analyser, but also affect the rise time. Also transport times inside of an analyser would be defined as analyser response time, like the converter or water traps inside of a NOx analyser. The determination of the total system response time is described in Appendix 2, paragraph 1.11.1.
Gas drying
Same specifications as for NRSC test cycle apply (paragraph 1.4.2.) as described here below. The optional gas drying device shall have a minimal effect on the concentration of the measured gases. Chemical dryers are not an acceptable method of removing water from the sample.
Annex 4A - Appendix 1
Analysers
Same specifications as for NRSC test cycle apply (paragraph 1.4.3.) as described here below. The gases to be measured shall be analysed with the following instruments. For non-linear analysers, the use of linearizing circuits is permitted.
Carbon monoxide (CO) analysis
The carbon monoxide analyser shall be of the non-dispersive infra-red (NDIR) absorption type.
Carbon dioxide (CO2) analysis
The carbon dioxide analyser shall be of the non-dispersive infra-red (NDIR) absorption type.
Hydrocarbon (HC) analysis
The hydrocarbon analyser shall be of the heated flame ionization detector (HFID) type with detector, valves, pipework etc., heated so as to maintain a gas temperature of 463K (190 °C) ±10 K.
Oxides of nitrogen (NOx) analysis
The oxides of nitrogen analyser shall be of the chemiluminescent detector (CLD) or heated chemiluminescent detector (HCLD) type with a NO2/NO converter, if measured on a dry basis. If measured on a wet basis, a HCLD with converter maintained above 328 K (55 °C shall be used, provided the water quench check (Annex 4A, Appendix 2, paragraph 1.9.2.2.) is satisfied. For both CLD and HCLD, the sampling path shall be maintained at a wall temperature of 328K to 473 K (55 to 200 °C) up to the converter for dry measurement, and up to the analyser for wet measurement.
Air to fuel measurement
The air to fuel measurement equipment used to determine the exhaust gas flow as specified in paragraph 2.2.3. shall be a wide range air to fuel ratio sensor or lambda sensor of Zirconia type. The sensor shall be mounted directly on the exhaust pipe where the exhaust gas temperature is high enough to eliminate water condensation. The accuracy of the sensor with incorporated electronics shall be within: ±3 per cent of reading λ < 2 ±5 per cent of reading 2 ≤ λ < 5 ±10 per cent of reading 5 ≤ λ To fulfil the accuracy specified above, the sensor shall be calibrated as specified by the instrument manufacturer.
Annex 4A - Appendix 1
Sampling of gaseous emissions
Raw exhaust gas flow
For calculation of the emissions in the raw exhaust gas the same specifications as for NRSC test cycle apply (paragraph 1.4.4.), as described here below. The gaseous emissions sampling probes shall be fitted at least 0.5 m or three times the diameter of the exhaust pipe — whichever is the larger — upstream of the exit of the exhaust gas system as far as applicable and sufficiently close to the engine as to ensure an exhaust gas temperature of at least 343 K (70 °C) at the probe. In the case of a multicylinder engine with a branched exhaust manifold, the inlet of the probe shall be located sufficiently far downstream so as to ensure that the sample is representative of the average exhaust emissions from all cylinders. In multicylinder engines having distinct groups of manifolds, such as in a "V"- engine configuration, it is permissible to acquire a sample from each group individually and calculate an average exhaust emission. Other methods which have been shown to correlate with the above methods may be used. For exhaust emissions calculation the total exhaust mass flow of the engine shall be used.
Diluted exhaust gas flow
If a full flow dilution system is used, the following specifications apply. The exhaust pipe between the engine and the full flow dilution system shall conform to the requirements of Annex 4A, Appendix 4. The gaseous emissions sample probe(s) shall be installed in the dilution tunnel at a point where the dilution air and exhaust gas are well mixed, and in close proximity to the particulates sampling probe. Sampling can generally be done in two ways:
(a) The pollutants are sampled into a sampling bag over the cycle and measured after completion of the test.
(b) The pollutants are sampled continuously and integrated over the cycle; this method is mandatory for HC and NOx. The background concentrations shall be sampled upstream of the dilution tunnel into a sampling bag, and shall be subtracted from the emissions concentration according to Appendix 3, paragraph 2.2.3.
Determination of the particulates
Determination of the particulates requires a dilution system. Dilution may be accomplished by a partial flow dilution system or a full flow dilution system. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems, and maintain the temperature of the diluted exhaust gas between 315 K (42 °C) and 325 K (52 °C) immediately upstream of the filter holders. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. Dilution air pre-heating above the temperature limit of 303 K (30 °C) is recommended if the ambient temperature is below 293 K (20 °C). However, the diluted air temperature shall not exceed 325 K (52 °C) prior to the introduction of the exhaust in the dilution tunnel.
Annex 4A - Appendix 1
The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, and the installation shall comply with the provisions of paragraph 2.3.5. To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, microgram balance, and a temperature and humidity controlled weighing chamber, are required. Partial flow dilution system specifications The partial flow dilution system has to be designed to split the exhaust stream into two fractions, the smaller one being diluted with air and subsequently used for particulate measurement. For this it is essential that the dilution ratio be determined very accurately. Different splitting methods can be applied, whereby the type of splitting used dictates to a significant degree the sampling hardware and procedures to be used (Annex 4A, Appendix 4, paragraph 1.2.1.1.). For the control of a partial flow dilution system, a fast system response is required. The transformation time for the system shall be determined by the procedure described in Appendix 2, paragraph 1.11.1. If the combined transformation time of the exhaust flow measurement (see previous paragraph) and the partial flow system is less than 0.3 s, online control may be used. If the transformation time exceeds 0.3 s, look ahead control based on a pre-recorded test run shall be used. In this case, the rise time shall be ≤ 1 s and the delay time of the combination ≤ 10 s. The total system response shall be designed as to ensure a representative sample of the particulates, GSE, proportional to the exhaust mass flow. To determine the proportionality, a regression analysis of GSE versus GEXHW shall be conducted on a minimum 5 Hz data acquisition rate, and the following criteria shall be met:
(a) The correlation coefficient r of the linear regression between GSE and GEXHW shall be not less than 0.95;
(b) The standard error of estimate of GSE on GEXHW shall not exceed 5 per cent of GSE maximum;
(c) GSE intercept of the regression line shall not exceed ±2 per cent of GSE maximum. Optionally, a pre-test may be run, and the exhaust mass flow signal of the pre- test be used for controlling the sample flow into the particulate system (look- ahead control). Such a procedure is required if the transformation time of the particulate system, t50,P or/and the transformation time of the exhaust mass flow signal, t50,F are > 0.3 s. A correct control of the partial dilution system is obtained, if the time trace of GEXHW,pre of the pre-test, which controls GSE, is shifted by a 'look-ahead' time of t50,P + t50,F. For establishing the correlation between GSE and GEXHW the data taken during the actual test shall be used, with GEXHW time aligned by t50,F relative to GSE (no contribution from t50,P to the time alignment). That is, the time shift between GEXHW and GSE is the difference in their transformation times that were determined in Appendix 2, paragraph 2.6.
Annex 4A - Appendix 1
For partial flow dilution systems, the accuracy of the sample flow GSE is of special concern, if not measured directly, but determined by differential flow measurement: GSE = GTOTW – GDILW In this case an accuracy of ±2 per cent for GTOTW and GDILW is not sufficient to guarantee acceptable accuracies of GSE. If the gas flow is determined by differential flow measurement, the maximum error of the difference shall be such that the accuracy of GSE is within ±5 per cent when the dilution ratio is less than 15. It can be calculated by taking the root-mean-square of the errors of each instrument. Acceptable accuracies of GSE can be obtained by either of the following methods:
(a) The absolute accuracies of GTOTW and GDILW are ±0.2 per cent which guarantees an accuracy of GSE of ≤ 5 per cent at a dilution ratio of 15. However, greater errors will occur at higher dilution ratios.
(b) Calibration of GDILW relative to GTOTW is carried out such that the same accuracies for GSE as in (a) are obtained. For the details of such a calibration see Appendix 2, paragraph 2.6.
(c) The accuracy of GSE is determined indirectly from the accuracy of the dilution ratio as determined by a tracer gas, e.g. CO2. Again, accuracies equivalent to method (a) for GSE are required.
(d) The absolute accuracy of GTOTW and GDILW is within ±2 per cent of full scale, the maximum error of the difference between GTOTW and GDILW is within 0.2 per cent, and the linearity error is within ±0.2 per cent of the highest GTOTW observed during the test.
Particulate sampling filters
Filter specification
Fluorocarbon coated glass fibre filters or fluorocarbon based membrane filters are required for certification tests. For special applications different filter materials may be used. All filter types shall have a 0.3 μm DOP (di- octylphthalate) collection efficiency of at least 99 per cent at a gas face velocity between 35 and 100 cm/s. When performing correlation tests between laboratories or between a manufacturer and an approval authority, filters of identical quality shall be used.
Filter size
Particulate filters shall have a minimum diameter of 47 mm (37 mm stain diameter). Larger diameter filters are acceptable (paragraph 2.4.1.5).
Primary and back-up filters
The diluted exhaust shall be sampled by a pair of filters placed in series (one primary and one back-up filter) during the test sequence. The back-up filter shall be located no more than 100 mm downstream of, and shall not be in contact with, the primary filter. The filters may be weighed separately or as a pair with the filters placed stain side to stain side.
Annex 4A - Appendix 1
Filter face velocity
A gas face velocity through the filter of 35 to 100 cm/s shall be achieved. The pressure drop increase between the beginning and the end of the test shall be no more than 25 kPa.
Filter loading
The recommended minimum filter loadings for the most common filter sizes are shown in the following table. For larger filter sizes, the minimum filter loading shall be 0.065 mg/1000 mm2 filter area.
Filter diameter Recommended stain diameter Recommended minimum loading
(mm) (mm) (mg)
47 37 0.11
70 60 0.25
90 80 0.41
110 100 0.62
Weighing chamber and analytical balance specifications
Weighing chamber conditions
The temperature of the chamber (or room) in which the particulate filters are conditioned and weighed shall be maintained to within 295 K (22 °C) ± 3 K during all filter conditioning and weighing. The humidity shall be maintained to a dewpoint of 282.5 (9.5 °C) ± 3 K and a relative humidity of 45 ± 8 per cent.
Reference filter weighing
The chamber (or room) environment shall be free of any ambient contaminants (such as dust) that would settle on the particulate filters during their stabilization. Disturbances to weighing room specifications as outlined in paragraph 2.4.2.1. will be allowed if the duration of the disturbances does not exceed 30 minutes. The weighing room should meet the required specifications prior to personnel entrance into the weighing room. At least two unused reference filters or reference filter pairs shall be weighed within four hours of, but preferably at the same time as the sample filter (pair) weighing. They shall be the same size and material as the sample filters. If the average weight of the reference filters (reference filter pairs) changes between sample filter weighing by more than 10 μg, then all sample filters shall be discarded and the emissions test repeated. If the weighing room stability criteria outlined in paragraph 2.4.2.1. are not met, but the reference filter (pair) weighing meet the above criteria, the engine manufacturer has the option of accepting the sample filter weights or voiding the tests, fixing the weighing room control system and re-running the test.
Annex 4A - Appendix 1
Analytical balance
The analytical balance used to determine the weights of all filters shall have a precision (standard deviation) of 2 μg and a resolution of 1 μg (1 digit = 1 μg) specified by the balance manufacturer.
Elimination of static electricity effects
To eliminate the effects of static electricity, the filters shall be neutralized prior to weighing, for example, by a Polonium neutralizer or a device having similar effect.
Additional specifications for particulate measurement
All parts of the dilution system and the sampling system from the exhaust pipe up to the filter holder, which are in contact with raw and diluted exhaust gas, shall be designed to minimize deposition or alteration of the particulates. All parts shall be made of electrically conductive materials that do not react with exhaust gas components, and shall be electrically grounded to prevent electrostatic effects.
Annex 4A - Appendix 2
Annex 4A - Appendix 2
Calibration procedure (NRSC, NRTC 1)
1.Calibration of the analytical instruments
Introduction
Each analyser shall be calibrated as often as necessary to fulfil the accuracy requirements of this Regulation. The calibration method that shall be used is described in this paragraph for the analysers indicated in Appendix 1, paragraph 1.4.3. At the request of the manufacturer and with the agreement of the approval authority the methods described in Annex 4B, paragraphs 8.1. and 8.2. may be used as an alternative to those in paragraph 1. of this appendix.
Calibration gases
The shelf life of all calibration gases shall be respected. The expiry date of the calibration gases stated by the manufacturer shall be recorded.
Pure gases
The required purity of the gases is defined by the contamination limits given below. The following gases shall be available for operation:
(a) Purified nitrogen (contamination ≤ 1 ppm C, ≤ 1 ppm CO, ≤ 400 ppm CO2, ≤ 0.1 ppm NO)
(b) Purified oxygen (purity > 99.5 per cent vol O2)
(c) Hydrogen-helium mixture (40 ± 2 per cent hydrogen, balance helium) (contamination ≤ 1 ppm C, ≤ 400 ppm CO2)
(d) Purified synthetic air (contamination ≤ 1 ppm C, ≤ 1 ppm CO, ≤ 400 ppm CO2, ≤ 0.1 ppm NO) (oxygen content between 18 – 21 per cent vol)
The calibration procedure is common for both NRSC and NRTC tests, with the exception of the requirements specified in paragraphs 1.11. and 2.6.
Annex 4A - Appendix 2
Calibration and span gases
Mixtures of gases having the following chemical compositions shall be available:
(a) C3H8 and purified synthetic air (see paragraph 1.2.1.);
(b) CO and purified nitrogen;
(c) NO and purified nitrogen (the amount of NO2 contained in this calibration gas shall not exceed 5 per cent of the NO content);
(d) O2 and purified nitrogen;
(e) CO2 and purified nitrogen;
(f) CH4 and purified synthetic air;
(g) C2H6 and purified synthetic air. Note: other gas combinations are allowed provided the gases do not react with one another. The true concentration of a calibration and span gas shall be within ±2 per cent of the nominal value. All concentrations of calibration gas shall be given on a volume basis (volume per cent or volume ppm). The gases used for calibration and span may also be obtained by means of a gas divider, diluting with purified N2 or with purified synthetic air. The accuracy of the mixing device shall be such that the concentration of the diluted calibration gases may be determined to within ±2 per cent. This accuracy implies that primary gases used for blending shall be known to have an accuracy of at least ±1 per cent, traceable to national or international gas standards. The verification shall be performed at between 15 and 50 per cent of full scale for each calibration incorporating a blending device. An additional verification may be performed using another calibration gas, if the first verification has failed. Optionally, the blending device may be checked with an instrument which by nature is linear, e.g. using NO gas with a CLD. The span value of the instrument shall be adjusted with the span gas directly connected to the instrument. The blending device shall be checked at the used settings and the nominal value shall be compared to the measured concentration of the instrument. This difference shall in each point be within ±1 per cent of the nominal value. Other methods may be used based on good engineering practice and with the prior agreement of the parties involved. Note: A precision gas divider of accuracy is within ±1 per cent, is recommended for establishing the accurate analyser calibration curve. The gas divider shall be calibrated by the instrument manufacturer.
Operating procedure for analysers and sampling system
The operating procedure for analysers shall follow the start-up and operating instructions of the instrument manufacturer. The minimum requirements given in paragraphs 1.4. to 1.9. shall be included.
Annex 4A - Appendix 2
Leakage test
A system leakage test shall be performed. The probe shall be disconnected from the exhaust system and the end plugged. The analyser pump shall be switched on. After an initial stabilization period all flow-meters should read zero. If not, the sampling lines shall be checked and the fault corrected. The maximum allowable leakage rate on the vacuum side shall be 0.5 per cent of the in-use flow rate for the portion of the system being checked. The analyser flows and bypass flows may be used to estimate the in-use flow rates. Another method is the introduction of a concentration step change at the beginning of the sampling line by switching from zero to span gas. If after an adequate period of time the reading shows a lower concentration compared to the introduced concentration, this points to calibration or leakage problems.
Calibration procedure
Instrument assembly
The instrument assembly shall be calibrated and calibration curves checked against standard gases. The same gas flow rates shall be used as when sampling exhaust.
Warming-up time
The warming-up time should be according to the recommendations of the manufacturer. If not specified, a minimum of two hours is recommended for warming-up the analysers.
NDIR and HFID analyser
The NDIR analyser shall be tuned, as necessary, and the combustion flame of the HFID analyser shall be optimized (paragraph 1.8.1.).
Calibration
Each normally used operating range shall be calibrated. Using purified synthetic air (or nitrogen), the CO, CO2, NOx, HC and O2 analysers shall be set at zero. The appropriate calibration gases shall be introduced to the analysers, the values recorded, and the calibration curve established according to paragraph 1.5.6. The zero setting shall be rechecked and the calibration procedure repeated, if necessary.
Establishment of the calibration curve
General guidelines
The analyser calibration curve is established by at least six calibration points (excluding zero) spaced as uniformly as possible. The highest nominal concentration shall be equal to or higher than 90 per cent of full scale. The calibration curve is calculated by the method of least squares. If the resulting polynomial degree is greater than three, the number of calibration points (zero included) shall be at least equal to this polynomial degree plus two.
Annex 4A - Appendix 2
The calibration curve shall not differ by more than ±2 per cent from the nominal value of each calibration point and by more than ±0.3 per cent of full scale at zero. From the calibration curve and the calibration points, it is possible to verify that the calibration has been carried out correctly. The different characteristic parameters of the analyser shall be indicated, particularly:
(a) The measuring range;
(b) The sensitivity;
(c) The date of carrying out the calibration.
Calibration below 15 per cent of full scale
The analyser calibration curve is established by at least ten calibration points (excluding zero) spaced so that 50 per cent of the calibration points are below 10 per cent of full scale. The calibration curve is calculated by the method of least squares. The calibration curve shall not differ by more than ±4 per cent from the nominal value of each calibration point and by more than ±0.3 per cent of full scale at zero.
Alternative methods
If it can be shown that alternative technology (e.g. computer, electronically controlled range switch, etc.) can give equivalent accuracy, then these alternatives may be used.
Verification of the calibration
Each normally used operating range shall be checked prior to each analysis in accordance with the following procedure. The calibration is checked by using a zero gas and a span gas whose nominal value is more than 80 per cent of full scale of the measuring range. If, for the two points considered, the value found does not differ by more than ±4 per cent of full scale from the declared reference value, the adjustment parameters may be modified. Should this not be the case, a new calibration curve shall be established in accordance with paragraph 1.5.4.
Efficiency test of the NOx converter
The efficiency of the converter used for the conversion of NO2 into NO is tested as given in paragraphs 1.7.1. to 1.7.8. (Figure 1).
Test set-up
Using the test set-up as shown in Figure 1 (see also Appendix 1, paragraph 1.4.3.5.) and the procedure below, the efficiency of converters can be tested by means of an ozonator.
Annex 4A - Appendix 2
Calibration
The CLD and the HCLD shall be calibrated in the most common operating range following the manufacturer's specifications using zero and span gas (the NO content of which shall amount to about 80 per cent of the operating range and the NO2 concentration of the gas mixture to less than 5 per cent of the NO concentration). The NOx analyser shall be in the NO mode so that the span gas does not pass through the converter. The indicated concentration has to be recorded.
Calculation
The efficiency of the NOx converter is calculated as follows: a-b Efficiency (%) = ( 1 + ) ⋅ 100 c-d where: a = NOx concentration according to paragraph 1.7.6. b = NOx concentration according to paragraph 1.7.7. c = NO concentration according to paragraph 1.7.4. d = NO concentration according to paragraph 1.7.5.
Adding of oxygen
Via a T-fitting, oxygen or zero air is added continuously to the gas flow until the concentration indicated is about 20 per cent less than the indicated calibration concentration given in paragraph 1.7.2. (The analyser is in the NO mode.)
Annex 4A - Appendix 2
The indicated concentration c shall be recorded. The ozonator is kept de- activated throughout the process.
Activation of the ozonator
The ozonator is now activated to generate enough ozone to bring the NO concentration down to about 20 per cent (minimum 10 per cent) of the calibration concentration given in paragraph 1.7.2. The indicated concentration d shall be recorded. (The analyser is in the NO mode.)
NOx mode
The NO analyser is then switched to the NOx mode so that the gas mixture (consisting of NO, NO2, O2 and N2) now passes through the converter. The indicated concentration a shall be recorded. (The analyser is in the NOx mode.)
De-activation of the ozonator
The ozonator is now de-activated. The mixture of gases described in paragraph 1.7.6. passes through the converter into the detector. The indicated concentration b shall be recorded. (The analyser is in the NOx mode.)
NO mode
Switched to NO mode with the ozonator de-activated, the flow of oxygen or synthetic air is also shut off. The NOx reading of the analyser shall not deviate by more than ±5 per cent from the value measured according to paragraph 1.7.2. (The analyser is in the NO mode.)
Test interval
The efficiency of the converter shall be tested prior to each calibration of the NOx analyser.
Efficiency requirement
The efficiency of the converter shall not be less than 90 per cent, but a higher efficiency of 95 per cent is strongly recommended. Note: If, with the analyser in the most common range, the ozonator cannot give a reduction from 80 per cent to 20 per cent according to paragraph 1.7.5., then the highest range which will give the reduction shall be used.
Adjustment of the FID
Optimization of the detector response
The HFID shall be adjusted as specified by the instrument manufacturer. A propane in air span gas should be used to optimize the response on the most common operating range. With the fuel and air flow rates set at the manufacturer's recommendations, a 350 ± 75 ppm C span gas shall be introduced to the analyser. The response at a given fuel flow shall be determined from the difference between the span gas response and the zero gas response. The fuel flow shall be incrementally adjusted above and below the manufacturer's specification. The span and zero response at these fuel flows shall be recorded. The difference between the span and zero response shall be plotted and the fuel flow adjusted to the rich side of the curve.
Annex 4A - Appendix 2
Hydrocarbon response factors
The analyser shall be calibrated using propane in air and purified synthetic air, according to paragraph 1.5. Response factors shall be determined when introducing an analyser into service and after major service intervals. The response factor (Rf) for a particular hydrocarbon species is the ratio of the FID C1 reading to the gas concentration in the cylinder expressed by ppm C1. The concentration of the test gas shall be at a level to give a response of approximately 80 per cent of full scale. The concentration shall be known to an accuracy of ±2 per cent in reference to a gravimetric standard expressed in volume. In addition, the gas cylinder shall be pre-conditioned for 24 hours at a temperature of 298 K (25 oC) ± 5 K. The test gases to be used and the recommended relative response factor ranges are as follows: Methane and purified synthetic air: 1.00 ≤ Rf ≤ 1.15 Propylene and purified synthetic air: 0.90 ≤ Rf ≤ 1.1 Toluene and purified synthetic air: 0.90 ≤ Rf ≤ 1.10 These values are relative to the response factor (Rf) of 1.00 for propane and purified synthetic air.
Oxygen interference check
The oxygen interference check shall be determined when introducing an analyser into service and after major service intervals. A range shall be chosen where the oxygen interference check gases will fall within the upper 50 per cent. The test shall be conducted with the oven temperature set as required.
Oxygen interference gases
Oxygen interference check gases shall contain propane with 350 ppmC to 75 ppmC hydrocarbon. The concentration value shall be determined to calibration gas tolerances by chromatographic analysis of total hydrocarbons plus impurities or by dynamic blending. Nitrogen shall be the predominant diluent with the balance oxygen. Blends required for Diesel engine testing are: O2 concentration Balance
21 (20 to 22) Nitrogen
10 (9 to 11) Nitrogen
5 (4 to 6) Nitrogen
Procedure
(a) The analyser shall be zeroed.
(b) The analyser shall be spanned with the 21 per cent oxygen blend.
(c) The zero response shall be rechecked. If it has changed more than 0.5 per cent of full scale sub-paragraphs (a) and (b) shall be repeated.
Annex 4A - Appendix 2
(d) The 5 per cent and 10 per cent oxygen interference check gases shall be introduced.
(e) The zero response shall be rechecked. If it has changed more than ±1 per cent of full scale, the test shall be repeated.
(f) The oxygen interference (%O2I) shall be calculated for each mixture in
(d) as follows: (B − C) % O 2I = ⋅ 100 B A = hydrocarbon concentration (ppmC) of the span gas used in (b) B = hydrocarbon concentration (ppmC) of the oxygen interference check gases used in (d) C = analyser response
( ppmC ) = A D D = per cent of full scale analyser response due to A.
(g) The per cent of oxygen interference (%O2I) shall be less than ±3.0 per cent for all required oxygen interference check gases prior to testing.
(h) If the oxygen interference is greater than ±3.0 per cent, the air flow above and below the manufacturer's specifications shall be incrementally adjusted, repeating paragraph 1.8.1. for each flow.
(i) If the oxygen interference is greater than ±3.0 per cent after adjusting the air flow, the fuel flow and thereafter the sample flow shall be varied, repeating paragraph 1.8.1. for each new setting.
(j) If the oxygen interference is still greater than ±3.0 per cent, the analyser, FID fuel, or burner air shall be repaired or replaced prior to testing. This paragraph shall then be repeated with the repaired or replaced equipment or gases.
Interference effects with NDIR and CLD analysers
Gases present in the exhaust other than the one being analysed can interfere with the reading in several ways. Positive interference occurs in NDIR instruments where the interfering gas gives the same effect as the gas being measured, but to a lesser degree. Negative interference occurs in NDIR instruments by the interfering gas broadening the absorption band of the measured gas, and in CLD instruments by the interfering gas quenching the radiation. The interference checks in paragraphs 1.9.1. and 1.9.2. shall be performed prior to an analyser's initial use and after major service intervals.
CO analyser interference check
Water and CO2 can interfere with the CO analyser performance. Therefore a CO2 span gas having a concentration of 80 to 100 per cent of full scale of the maximum operating range used during testing shall be bubbled through water at room temperature and the analyser response recorded. The analyser response shall not be more than 1 per cent of full scale for ranges equal to or above 300 ppm or more than 3 ppm for ranges below 300 ppm.
Annex 4A - Appendix 2
NOx analyser quench checks
The two gases of concern for CLD (and HCLD) analysers are CO2 and water vapour. Quench responses of these gases are proportional to their concentrations, and therefore require test techniques to determine the quench at the highest expected concentrations experienced during testing.
CO2 quench check
A CO2 span gas having a concentration of 80 to 100 per cent of full scale of the maximum operating range shall be passed through the NDIR analyser and the CO2 value recorded as A. It shall then be diluted approximately 50 per cent with NO span gas and passed through the NDIR and (H)CLD with the CO2 and NO values recorded as B and C, respectively. The CO2 shall be shut off and only the NO span gas be passed through the (H)CLD and the NO value recorded as D. The quench shall be calculated as follows: ⎡ ⎛ C⋅A ⎞⎤ % CO 2 Quench = ⎢ 1 - ⎜⎜ ⎟⎟ ⎥ ⋅ 100 ⎣ ⎝ (D ⋅ A) - (D ⋅ B) ⎠ ⎦ and shall not be greater than 3 per cent of full scale. where: A = undiluted CO2 concentration measured with NDIR per cent B = diluted CO2 concentration measured with NDIR per cent C = diluted NO concentration measured with CLD ppm D = undiluted NO concentration measured with CLD ppm
Water quench check
This check applies to wet gas concentration measurements only. Calculation of water quench shall consider dilution of the NO span gas with water vapour and scaling of water vapour concentration of the mixture to that expected during testing. A NO span gas having a concentration of 80 to 100 per cent of full scale to the normal operating range shall be passed through the (H)CLD and the NO value recorded as D. The NO gas shall be bubbled through water at room temperature and passed through the (H)CLD and NO value recorded as C. The water temperature shall be determined and recorded as F. The mixture's saturation vapour pressure that corresponds to the bubbler water temperature (F) shall be determined and recorded as G. The water vapour concentration (in per cent) of the mixture shall be calculated as follows: G H = 100 ⋅ ( ) pB
and recorded as H. The expected diluted NO span gas (in water vapour) concentration shall be calculated as follows: ⎛ H ⎞ De = D ⋅ ⎜ 1 - ⎟ ⎝ 100 ⎠ and recorded as De. For diesel exhaust, the maximum exhaust water vapour concentration (in per cent) expected during testing shall be estimated, under the
Annex 4A - Appendix 2
assumption of a fuel atom H/C ratio of 1.8 to 1.0, from the maximum CO2 concentration in the exhaust gas or from the undiluted CO2 span gas concentration (A, as measured in paragraph 1.9.2.1.) as follows: Hm = (0.9 · A) and recorded as Hm. The water quench shall be calculated as follows:
⎛ De − C ⎞ ⎛ Hm ⎞ % H 2 O Quench = 100 ⋅ ⎜ ⎟⋅⎜ ⎟ ⎝ De ⎠ ⎝ H ⎠ and shall not be greater than 3 per cent of full scale. De = expected diluted NO concentration (ppm) C = diluted NO concentration (ppm) Hm = maximum water vapour concentration (per cent) H = actual water vapour concentration (per cent) Note: It is important that the NO span gas contains minimal NO2 concentration for this check, since absorption of NO2 in water has not been accounted for in the quench calculations.
Calibration intervals
The analysers shall be calibrated according to paragraph 1.5. at least every three months or whenever a system repair or change is made that could influence calibration.
Additional calibration requirements for raw exhaust measurements over NRTC test
Response time check of the analytical system
The system settings for the response time evaluation shall be exactly the same as during measurement of the test run (i.e. pressure, flow rates, filter settings on the analysers and all other response time influences). The response time determination shall be done with gas switching directly at the inlet of the sample probe. The gas switching shall be done in less than 0.1 s. The gases used for the test shall cause a concentration change of at least 60 per cent FS. The concentration trace of each single gas component shall be recorded. The response time is defined as the difference in time between the gas switching and the appropriate change of the recorded concentration. The system response time (t90) consists of the delay time to the measuring detector and the rise time of the detector. The delay time is defined as the time from the change (t0) until the response is 10 per cent of the final reading (t10). The rise time is defined as the time between 10 and 90 per cent response of the final reading (t90 – t10). For time alignment of the analyser and exhaust flow signals in the case of raw measurement, the transformation time is defined as the time from the change
(t0) until the response is 50 per cent of the final reading (t50). The system response time shall be ≤ 10 s with a rise time ≤ 2.5 s for all limited components (CO, NOx, HC) and all ranges used.
Annex 4A - Appendix 2
Calibration of tracer gas analyser for exhaust flow measurement
The analyser for measurement of the tracer gas concentration, if used, shall be calibrated using the standard gas. The calibration curve shall be established by at least 10 calibration points (excluding zero) spaced so that a half of the calibration points are placed between 4 to 20 per cent of analyser's full scale and the rest are in between 20 to 100 per cent of the full scale. The calibration curve is calculated by the method of least squares. The calibration curve shall not differ by more than ±1 per cent of the full scale from the nominal value of each calibration point, in the range from 20 to 100 per cent of the full scale. It shall also not differ by more than ±2 per cent from the nominal value in the range from 4 to 20 per cent of the full scale. The analyser shall be set at zero and spanned prior to the test run using a zero gas and a span gas whose nominal value is more than 80 per cent of the analyser full scale.
2.Calibration of the particulate measuring system
Introduction
Each component shall be calibrated as often as necessary to fulfil the accuracy requirements of this Regulation. The calibration method to be used is described in this paragraph for the components indicated in Annex 4A, Appendix 1, paragraph 1.5. and Appendix 4. At the request of the manufacturer and with the agreement of the approval authority the methods described in Annex 4B, paragraphs 8.1. and 8.2. may be used as an alternative to those in paragraph 2. of this appendix.
Flow measurement
The calibration of gas flow-meters or flow measurement instrumentation shall be traceable to national and/or international standards. The maximum error of the measured value shall be within ±2 per cent of reading. For partial flow dilution systems, the accuracy of the sample flow GSE is of special concern, if not measured directly, but determined by differential flow measurement: GSE = GTOTW – GDILW In this case an accuracy of ±2 per cent for GTOTW and GDILW is not sufficient to guarantee acceptable accuracies of GSE. If the gas flow is determined by differential flow measurement, the maximum error of the difference shall be such that the accuracy of GSE is within ±5 per cent when the dilution ratio is less than 15. It can be calculated by taking root-mean-square of the errors of each instrument.
Checking the dilution ratio
When using particulate sampling systems without EGA (Annex 4A, Appendix 4, paragraph 1.2.1.1.), the dilution ratio shall be checked for each new engine installation with the engine running and the use of either the CO2 or NOx concentration measurements in the raw and dilute exhaust.
Annex 4A - Appendix 2
The measured dilution ratio shall be within ±10 per cent of the calculated dilution ratio from CO2 or NOx concentration measurement.
Checking the partial flow conditions
The range of the exhaust gas velocity and the pressure oscillations shall be checked and adjusted according to the requirements of Annex 4A, Appendix 4, paragraph 1.2.1.1., EP, if applicable.
Calibration intervals
The flow measurement instrumentation shall be calibrated at least every three months, or whenever a system change is made that could influence calibration.
Additional calibration requirements for partial flow dilution systems
Periodical calibration
If the sample gas flow is determined by differential flow measurement the flow-meter or the flow measurement instrumentation shall be calibrated by one of the following procedures, such that the probe flow GSE into the tunnel fulfils the accuracy requirements of Annex 4A, Appendix 1, paragraph 2.4.: The flow-meter for GDILW is connected in series to the flow-meter for GTOTW, the difference between the two flow-meters is calibrated for at least five set points with flow values equally spaced between the lowest GDILW value used during the test and the value of GTOTW used during the test. The dilution tunnel may be bypassed. A calibrated mass flow device is connected in series to the flow-meter for GTOTW and the accuracy is checked for the value used for the test. Then the calibrated mass flow device is connected in series to the flow-meter for GDILW, and the accuracy is checked for at least five settings corresponding to the dilution ratio between 3 and 50, relative to GTOTW used during the test. The transfer tube TT is disconnected from the exhaust, and a calibrated flow measuring device with a suitable range to measure GSE is connected to the transfer tube. Then GTOTW is set to the value used during the test, and GDILW is sequentially set to at least five values corresponding to dilution ratios q between 3 and 50. Alternatively, a special calibration flow path may be provided, in which the tunnel is bypassed, but the total and dilution air flow through the corresponding meters are maintained as in the actual test. A tracer gas is fed into the transfer tube TT. This tracer gas may be a component of the exhaust gas, like CO2 or NOx. After dilution in the tunnel the tracer gas component is measured. This shall be carried out for five dilution ratios between 3 and 50. The accuracy of the sample flow is determined from the dilution ratio q: GSE = GTOTW / q The accuracies of the gas analysers shall be taken into account to guarantee the accuracy of GSE.
Carbon flow check
A carbon flow check using actual exhaust is strongly recommended for detecting measurement and control problems and verifying the proper operation of the partial flow dilution system. The carbon flow check should be
Annex 4A - Appendix 2
run at least each time a new engine is installed, or something significant is changed in the test cell configuration. The engine shall be operated at peak torque load and speed or any other steady- state mode that produces 5 per cent or more of CO2. The partial flow sampling system shall be operated with a dilution factor of about 15 to 1.
Pre-test check
A pre-test check shall be performed within two hours before the test run in the following way: The accuracy of the flow-meters shall be checked by the same method as used for calibration for at least two points, including flow values of GDILW that correspond to dilution ratios between five and 15 for the GTOTW value used during the test. If it can be demonstrated by records of the calibration procedure described above that the flow-meter calibration is stable over a longer period of time, the pre-test check may be omitted.
Determination of the transformation time
The system settings for the transformation time evaluation shall be exactly the same as during measurement of the test run. The transformation time shall be determined by the following method: An independent reference flow-meter with a measurement range appropriate for the probe flow shall be put in series with and closely coupled to the probe. This flow-meter shall have a transformation time of less than 100 ms for the flow step size used in the response time measurement, with flow restriction sufficiently low not to affect the dynamic performance of the partial flow dilution system, and consistent with good engineering practice. A step change shall be introduced to the exhaust flow (or air flow if exhaust flow is calculated) input of the partial flow dilution system, from a low flow to at least 90 per cent of full scale. The trigger for the step change should be the same one as that used to start the look-ahead control in actual testing. The exhaust flow step stimulus and the flow-meter response shall be recorded at a sample rate of at least 10 Hz. From this data, the transformation time shall be determined for the partial flow dilution system, which is the time from the initiation of the step stimulus to the 50 per cent point of the flow-meter response. In a similar manner, the transformation times of the GSE signal of the partial flow dilution system and of the GEXHW signal of the exhaust flow-meter shall be determined. These signals are used in the regression checks performed after each test (Annex 4A, Appendix 1, paragraph 2.4.). The calculation shall be repeated for at least five rise-and-fall stimuli, and the results shall be averaged. The internal transformation time (< 100 ms) of the reference flow-meter shall be subtracted from this value. This is the 'look- ahead' value of the partial flow dilution system, which shall be applied in accordance with Annex 4A, Appendix 1, paragraph 2.4.
Annex 4A - Appendix 2
3.Calibration of the CVS system
General
The CVS system shall be calibrated by using an accurate flow-meter and means to change operating conditions. The flow through the system shall be measured at different flow operating settings, and the control parameters of the system shall be measured and related to the flow. Various types of flow-meters may be used, e.g. calibrated venturi, calibrated laminar flow-meter, calibrated turbine meter. At the request of the manufacturer and with the agreement of the approval authority the methods described in Annex 4B, paragraphs 8.1. and 8.2. may be used as an alternative to those in paragraph 3. of this appendix.
Calibration of the positive displacement pump (PDP)
All the parameters related to the pump shall be simultaneously measured along with the parameters related to a calibration venturi which is connected in series with the pump. The calculated flow rate (in m3/min at pump inlet, absolute pressure and temperature) shall be plotted against a correlation function which is the value of a specific combination of pump parameters. The linear equation which relates the pump flow and the correlation function shall be determined. If a CVS has a multiple speed drive, the calibration shall be performed for each range used. Temperature stability shall be maintained during calibration. Leaks in all the connections and ducting between the calibration venturi and the CVS pump shall be maintained lower than 0.3 per cent of the lowest flow point (highest restriction and lowest PDP speed point).
Data analysis
The air flowrate (Qs) at each restriction setting (minimum 6 settings) shall be calculated in standard m3/min. from the flow-meter data using the manufacturer's prescribed method. The air flow rate shall then be converted to pump flow (V0) in m3/rev at absolute pump inlet temperature and pressure as follows: Qs T 101.3 V0 = · · n 273 PA
where: Qs = air flow rate at standard conditions (101.3 kPa, 273 K) (m3/s) T = temperature at pump inlet (K) pA = absolute pressure at pump inlet (pB – p1) (kPa) n = pump speed (rev/s) To account for the interaction of pressure variations at the pump and the pump slip rate, the correlation function (X0) between pump speed, pressure differential from pump inlet to pump outlet and absolute pump outlet pressure shall be calculated as follows:
Annex 4A - Appendix 2
1 · Δp p X0 = n pA where, Δp p = pressure differential from pump inlet to pump outlet (kPa) pA = absolute outlet pressure at pump outlet (kPa) A linear least-square fit shall be performed to generate the calibration equation as follows: V0 = D0 − m · ( X 0 ) D0 and m are the intercept and slope constants, respectively, describing the regression lines. For a CVS system with multiple speeds, the calibration curves generated for the different pump flow ranges shall be approximately parallel, and the intercept values (D0) shall increase as the pump flow range decreases. The values calculated by the equation shall be within ±0.5 per cent of the measured value of V0. Values of m will vary from one pump to another. Particulate influx over time will cause the pump slip to decrease, as reflected by lower values for m. Therefore, calibration shall be performed at pump start-up, after major maintenance, and if the total system verification (paragraph 3.5.) indicates a change in the slip rate.
Calibration of the critical flow venturi (CFV)
Calibration of the CFV is based upon the flow equation for a critical venturi. Gas flow is a function of inlet pressure and temperature, as shown below: Kv · pA Qs = T where, Kv = calibration coefficient pA = absolute pressure at venturi inlet (kPa) T = temperature at venturi inlet (K)
Data analysis
The air flow rate (Qs) at each restriction setting (minimum 8 settings) shall be calculated in standard m3/min. from the flow-meter data using the manufacturer's prescribed method. The calibration coefficient shall be calculated from the calibration data for each setting as follows: QS · T Kv = pA
where: Qs = air flow rate at standard conditions (101.3 kPa, 273 K) (m3/s) T = temperature at the venturi inlet (K) pA = absolute pressure at venturi inlet (kPa)
Annex 4A - Appendix 2
To determine the range of critical flow, Kv shall be plotted as a function of venturi inlet pressure. For critical (choked) flow, Kv will have a relatively constant value. As pressure decreases (vacuum increases), the venturi becomes unchoked and Kv decreases, which indicates that the CFV is operated outside the permissible range. For a minimum of eight points in the region of critical flow, the average KV and the standard deviation shall be calculated. The standard deviation shall not exceed ±0.3 per cent of the average KV.
Calibration of the subsonic venturi (SSV)
Calibration of the SSV is based upon the flow equation for a subsonic venturi. Gas flow is a function of inlet pressure and temperature, pressure drop between the SSV inlet and throat, as shown below:
⎡1 ⎛ ⎞⎤ ( Q SSV = A 0 d 2 C d P A ⎢ r 1.4286 − r 1.7143 ⎜ )1 ⎟⎥ ⎜ 1 − β 4 r 1.4286 ⎟⎥ ⎢⎣ T ⎝ ⎠⎦ where: A0 = collection of constants and units conversions = ⎛ 12 ⎞ ⎛ 0.006111 in SI units ⎜ m 3 ⎞⎜ K ⎟⎛ 1 ⎞ ⎜ min ⎟⎟⎜ kPa ⎟⎜ mm 2 ⎟ ⎝ ⎠⎜ ⎟⎝ ⎠ ⎝ ⎠ d = diameter of the SSV throat (m) Cd = discharge coefficient of the SSV pA = absolute pressure at venturi inlet (kPa) T = temperature at the venturi inlet (K) ΔP 1− r = ratio of the SSV throat to inlet absolute, static pressure = PA
ß = ratio of the SSV throat diameter, d, to the inlet pipe inner d diameter = D
Data analysis
The air flow rate (QSSV) at each flow setting (minimum 16 settings) shall be calculated in standard m3/min from the flow-meter data using the manufacturer's prescribed method. The discharge coefficient shall be calculated from the calibration data for each setting as follows: Q SSV Cd = ⎡1 ⎛ 1 ⎞⎤ ( A 0 d 2 P A ⎢ r 1.4286 − r 1.7143 ⎜ ⎜ ) ⎟⎥ 4 1.4286 ⎟ ⎢⎣ T ⎝1− β r ⎠⎥⎦
Annex 4A - Appendix 2
where: QSSV = air flow rate at standard conditions (101.3 kPa, 273 K), m3/s T = temperature at the venturi inlet (K) d = diameter of the SSV throat (m) r = ratio of the SSV throat to inlet absolute, static pressure = ΔP 1− PA ß = ratio of the SSV throat diameter, d, to the inlet pipe inner diameter = d D To determine the range of subsonic flow, Cd shall be plotted as a function of Reynolds number, at the SSV throat. The Re at the SSV throat is calculated with the following formula: QSSV Re = A1 dμ where: A1 = a collection of constants and units conversions =
25.55152 ⎛⎜ 1 ⎞ ⎛ min ⎞⎛ mm ⎞ ⎟⎜ ⎟⎜ ⎟ ⎝ m ⎠ ⎝ s ⎠⎝ m ⎠ QSSV = air flow rate at standard conditions (101.3 kPa, 273 K) (m3/s) d = diameter of the SSV throat (m) μ = absolute or dynamic viscosity of the gas, calculated with the following formula: 3 1 bT 2 bT 2 kg/m·s μ= = S +T S 1+ T where: kg 1.458 ⋅ 10 b = empirical constant = 1
msK 2 S = empirical constant = 104.4 K Because QSSV is an input to the Re formula, the calculations shall be started with an initial guess for QSSV or Cd of the calibration venturi, and repeated until QSSV converges. The convergence method shall be accurate to 0.1 per cent or better. For a minimum of sixteen points in the subsonic flow region, the calculated values of Cd from the resulting calibration curve fit equation shall be within ±0.5 per cent of the measured Cd for each calibration point.
Annex 4A - Appendix 2
Total system verification
The total accuracy of the CVS sampling system and analytical system shall be determined by introducing a known mass of a pollutant gas into the system while it is being operated in the normal manner. The pollutant is analysed, and the mass calculated according to Annex 4A, Appendix 3, paragraph 2.4.1. except in the case of propane where a factor of 0.000472 is used in place of 0.000479 for HC. Either of the following two techniques shall be used.
Metering with a critical flow orifice
A known quantity of pure gas (propane) shall be fed into the CVS system through a calibrated critical orifice. If the inlet pressure is high enough, the flow rate, which is adjusted by means of the critical flow orifice, is independent of the orifice outlet pressure (critical flow). The CVS system shall be operated as in a normal exhaust emission test for about five to 10 minutes. A gas sample shall be analysed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated. The mass so determined shall be within ±3 per cent of the known mass of the gas injected.
Metering by means of a gravimetric technique
The weight of a small cylinder filled with propane shall be determined with a precision of ±0.01 g. For about five to 10 minutes, the CVS system shall be operated as in a normal exhaust emission test, while carbon monoxide or propane is injected into the system. The quantity of pure gas discharged shall be determined by means of differential weighing. A gas sample shall be analysed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated. The mass so determined shall be within ±3 per cent of the known mass of the gas injected.
Annex 4A - Appendix 3
Annex 4A - Appendix 3
Data evaluation and calculations
1.Data evaluation and calculations – NRSC test
Gaseous emissions data evaluation
For the evaluation of the gaseous emissions, the chart reading of the last 60 s of each mode shall be averaged, and the average concentrations (conc) of HC, CO, NOx and CO2 if the carbon balance method is used, during each mode shall be determined from the average chart readings and the corresponding calibration data. A different type of recording can be used if it ensures an equivalent data acquisition. The average background concentrations (concd) may be determined from the bag readings of the dilution air or from the continuous (non-bag) background reading and the corresponding calibration data. If the ramped modal cycles of Annex 5, sub-paragraphs (a) or (b) of paragraph 1.2., respectively, are used, the data evaluation and calculation procedures of Annex 4B, paragraph 7.8.2.2., and the applicable sections of paragraphs A.8.2., A.8.3. and A.8.4. shall apply. The final test results shall be calculated according to equations A.8-60 and A.8-61 or A.7-49 and A.7-50, respectively.
Particulate emissions
For the evaluation of the particulates, the total sample masses (MSAM,i) through the filters shall be recorded for each mode. The filters shall be returned to the weighing chamber and conditioned for at least one hour, but not more than 80 hours, and then weighed. The gross weight of the filters shall be recorded and the tare weight (see paragraph 3.1., Annex 4A) subtracted. The particulate mass (Mf for single filter method; Mf,i for the multiple filter method) is the sum of the particulate masses collected on the primary and back-up filters. If background correction is to be applied, the dilution air mass (MDIL) through the filters and the particulate mass (Md) shall be recorded. If more than one measurement was made, the quotient Md/MDIL shall be calculated for each single measurement and the values averaged. If the ramped modal cycles of Annex 5, sub-paragraphs (a) or (b) of paragraph 1.2., respectively, are used, the data evaluation and calculation procedures of Annex 4B, paragraph 7.8.2.2., and the applicable sections of paragraphs A.8.2., A.8.3. and A.8.4. shall apply. The final test results shall be calculated according to equation A.8-64 or A.7-53, respectively.
Calculation of the gaseous emissions
The finally reported test results shall be derived through the following steps:
Determination of the exhaust gas flow
The exhaust gas flow rate (GEXHW,i) shall be determined for each mode according to Annex 4A, Appendix 1, paragraphs 1.2.1. to 1.2.3.
Annex 4A - Appendix 3
When using a full flow dilution system, the total dilute exhaust gas flow rate (GTOTW,i) shall be determined for each mode according to Annex 4A, Appendix 1, paragraph 1.2.4.
Dry/wet correction
Dry/wet correction (GEXHW,i) shall be determined for each mode according to Annex 4A, Appendix 1, paragraphs 1.2.1. to 1.2.3. When applying GEXHW the measured concentration shall be converted to a wet basis according to the following formulae, if not already measured on a wet basis: concwet = Kw · concdry For the raw exhaust gas: ⎛ 1 ⎞ K w,r = ⎜ ⎟ - K w1 ⎝ 1 + 1.88 ⋅ 0.005 ⋅ ( % CO[dry] + % CO 2 [dry]) ⎠ 1.608 ⋅ H a K W1= 1000 + (1.608 ⋅ H a ) 6.22 ⋅ Ra ⋅ pa Ha= p B - pa ⋅ Ra ⋅ 10-2 For the diluted gas: ⎛ 1.88 ⋅ CO 2 % (wet) ⎞ K w,e,1 = ⎜ 1 - ⎟ - K w2 ⎝ 200 ⎠ or: ⎛ ⎞ ⎜ 1 - K w2 ⎟ K w,e,2 = ⎜ 1 + ⎜ 1.88 ⋅ CO 2 % (dry) ⎟⎟ 1+ ⎝ 200 ⎠ 1.608 ⋅ [ H d ⋅ (1 - 1 / DF) + H a ⋅ (1 / DF)] KW 2= 1000 + 1.608 ⋅ [ H d ⋅ (1 - 1 / DF) + H a ⋅ (1 / DF)] For the dilution air:
K W,d = 1 - K W 3 1.608 ⋅ H d KW 3 = 1000 + ( 1.608 ⋅ H d )
6.22 ⋅ R d ⋅ p d H d= p B - p d ⋅ R d ⋅ 10 - 2
For the intake air (if different from the dilution air): K W, a = 1 - K W 2 1.608 ⋅ H a K W2 = 1000 + (1.608 ⋅ H a )
Annex 4A - Appendix 3
6.22 ⋅ Ra ⋅ pa Ha= p B - pa ⋅ Ra ⋅ 10-2 where: Ha = absolute humidity of the intake air (g water per kg dry air) Hd = absolute humidity of the dilution air (g water per kg dry air) Rd = relative humidity of the dilution air (per cent) Ra = relative humidity of the intake air (per cent) pd = saturation vapour pressure of the dilution air (kPa) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha and Hd may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Humidity correction for NOx
As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for ambient air temperature and humidity by the factors KH given in the following formula: 1 7 = K
A
B +
- . +
- Ha
Ta H
︵⋅ ︶ ︵⋅ ︶
where: A = 0.309 GFuel / GAIRD - 0.0266 B = –0.209 GFuel / GAIRD + 0.00954 G FUEL = Fuel air ratio (dry air basis) G AIRD Ta = temperatures of the air in (K) Ha = humidity of the intake air (g water per kg dry air): p a1 . 2 - 2 pa RaRa = Ha
⋅ ⋅ pB
-
⋅ ⋅
where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Annex 4A - Appendix 3
Calculation of emission mass flow rates
The emission mass flow rates for each mode shall be calculated as follows:
(a) For the raw exhaust gas 1: Gasmass = u · conc · GEXHW
(b) For the dilute exhaust gas 2: Gasmass = u · concc · GTOTW where: concc is the background corrected concentration concc = conc – concd · (1 - (1 / DF)) DF = 13.4 / (concCO2 + (concCO + concHC) · 10-4) or: DF = 13.4 / concCO2 The coefficients u – wet shall be used according to Table 5:
Values of the coefficient u – wet for various exhaust components
Gas u conc NOx 0.001587 ppm CO 0.000966 ppm HC 0.000479 ppm CO2 15.19 per cent The density of HC is based upon an average carbon to hydrogen ratio of 1:1.85.
Calculation of the specific emissions
The specific emission (g/kWh) shall be calculated for all individual components in the following way: n
∑ Gas mass ⋅ WF i i
Individual gas = i=1 n
∑ p ⋅ WF i=1 i i
where Pi = Pm, i + PAE, i.
In the case of NOx, the NOx concentration (NOxconc or NOxconcc) has to be multiplied by KHNOx (humidity correction factor for NOx quoted in section 1.3.3) as follows: KHNOx · conc or KHNOx · concc In the case of NOx, the NOx concentration (NOxconc or NOxconcc) has to be multiplied by KHNOx (humidity correction factor for NOx quoted in section 1.3.3) as follows: KHNOx · conc or KHNOx · concc
Annex 4A - Appendix 3 The weighing factors and the number of modes (n) used in the above calculation are according to Annex 4A, paragraph 3.7.1.
Calculation of the particulate emission
The particulate emission shall be calculated in the following way:
Humidity correction factor for particulates
As the particulate emission of diesel engines depends on ambient air conditions, the particulate mass flow rate shall be corrected for ambient air humidity with the factor Kp given in the following formula: Kp = 1/ (1 + 0.0133 · (Ha - 10.71) ) where: Ha = humidity of the intake air, gram of water per kg dry air p a1 . 2 - 2 pa RaRa = Ha
⋅ ⋅ pB
-
⋅ ⋅
where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Partial flow dilution system
The final reported test results of the particulate emission shall be derived through the following steps. Since various types of dilution rate control may be used, different calculation methods for equivalent diluted exhaust gas mass flow rate GEDF apply. All calculations shall be based upon the average values of the individual modes (i) during the sampling period.
Isokinetic systems
GEDFW, i = GEXHW, i · qi
G DILW ,i + ( G EXHW ,i ⋅ r ) qi = ( G EXHW ,i ⋅ r ) where r corresponds to the ratio of the cross sectional areas of the isokinetic probe Ap and exhaust pipe AT:
Ap r= AT
Systems with measurement of CO2 or NOx concentration
GEDFW, i = GEXHW, i · qi
Conc E, i - Conc A, i qi = Conc D, i - Conc A, i
Annex 4A - Appendix 3 where: ConcE = wet concentration of the tracer gas in raw exhaust ConcD = wet concentration of the tracer gas in the diluted exhaust ConcA = wet concentration of the tracer gas in the dilution air Concentrations measured on a dry basis shall be converted to a wet basis according to paragraph 1.3.2.
Systems with CO2 measurement and carbon balance method
206.6 ⋅ G FUEL,i G EDFW ,i = CO 2 D,i - CO 2 A,i where: CO2D = CO2 concentration of the diluted exhaust CO2A = CO2 concentration of the dilution air (concentrations in volume per cent on wet basis) This equation is based upon the carbon balance assumption (carbon atoms supplied to the engine are emitted as CO2) and derived through the following steps: GEDFW, i = GEXHW, i · qi and: 206.6 ⋅ G FUEL,i qi = G EXHW,i ⋅ ( CO 2 D ,i - CO 2 A ,i )
Systems with flow measurement
GEDFW, i = GEXHW, i · qi G TOTw,i qi = ( G TOTw,i - G DILW ,i )
Full flow dilution system
The final reported test results of the particulate emission shall be derived through the following steps. All calculations shall be based upon the average values of the individual modes
(i) during the sampling period. GEDFW, i = GTOTW, i
Calculation of the particulate mass flow rate
The particulate mass flow rate shall be calculated as follows: For the single filter method: M f ⋅ (G EDFW ) aver PT mass = M SAM ⋅ 1000
Annex 4A - Appendix 3 where: (GEDFW)aver over the test cycle shall be determined by summation of the average values of the individual modes during the sampling period: n (G EDFW ) aver = ∑ G EDFW,i ⋅ WF i i =1
n
M SAM = ∑ M SAM ,i i =1
where i = 1, . . . n For the multiple filter method:
M f ,i ⋅ (G EDFW,i )aver PT mass,i = M SAM,i ⋅ 1000 where i = 1, . . . n The particulate mass flow rate may be background corrected as follows: For single filter method:
⎡ M ⎛ Md ⎛ n ⎛ 1 ⎞ ⎞ ⎞ ⎤ (G ) PTmass = ⎢ f −⎜ ⋅ ⎜⎜ ∑ ⎜ 1 − ⎟ ⋅ WFi ⎟⎟ ⎟ ⎥ ⋅ EDFW aver M ⎜ M DFi ⎠ ⎟ 1000 ⎣⎢ SAM ⎝ DIL ⎝ i =1 ⎝ ⎠ ⎠ ⎦⎥
If more than one measurement is made, (Md/MDIL) shall be replaced with (Md/MDIL)aver 13.4 DF = conc + (concCO + concHC ) ⋅ 10- 4 C O
or: DF = 13.4 / concCO2 For multiple filter method:
⎡ M f ,i ⎛ M d ⎛ 1 ⎞ ⎞ ⎤ ⎡ G EDFW,i ⎤ PT mass, i = ⎢ -⎜ ⋅ ⎜1 - ⎟ ⎟⎥ ⋅ ⎢ ⎥ I L
⎣ M SAM , i ⎝ M D ⎝ DF ⎠ ⎠ ⎦ ⎣ 1000 ⎦ If more than one measurement is made, (Md/MDIL) shall be replaced with (Md/MDIL)aver 13.4 DF = + ( concCO + concHC ) ⋅ 10 - 4 C O
conc or: DF = 13.4 / concCO2
Annex 4A - Appendix 3
Calculation of the specific emissions
The specific emission of particulates PT (g/kWh) shall be calculated in the following way 3: For the single filter method:
PT = n PT mass ∑ P i ⋅ WF i i =1
For the multiple filter method: n
∑ PT i =1 mass,i ⋅ WF i PT = n
∑ P ⋅ WF i =1 i i
Effective weighing factor
For the single filter method, the effective weighing factor WFE, i for each mode shall be calculated in the following way:
M SAM , i ⋅ (G EDF ) aver WF E,i = M SAM ⋅ (G EDFW , i ) where i = l, . . . n. The value of the effective weighing factors shall be within ±0,005 (absolute value) of the weighing factors listed in Annex 4A, paragraph 3.7.1.
2.Data evaluation and calculations (NRTC test)
The two following measurement principles that can be used for the evaluation of pollutant emissions over the NRTC cycle are described in this paragraph:
(a) The gaseous components are measured in the raw exhaust gas on a real- time basis, and the particulates are determined using a partial flow dilution system;
(b) The gaseous components and the particulates are determined using a full flow dilution system (CVS system).
Calculation of gaseous emissions in the raw exhaust gas and of the particulate emissions with a partial flow dilution system
Introduction
The instantaneous concentration signals of the gaseous components are used for the calculation of the mass emissions by multiplication with the instantaneous exhaust mass flow rate. The exhaust mass flow rate may be measured directly, or calculated using the methods described in Annex 4A, Appendix 1, paragraph 2.2.3. (intake air and fuel flow measurement, tracer
The particulate mass flow rate PTmass has to be multiplied by Kp (humidity correction factor for particulates quoted in section 1.4.1).
Annex 4A - Appendix 3 method, intake air and air/fuel ratio measurement). Special attention shall be paid to the response times of the different instruments. These differences shall be accounted for by time aligning the signals. For particulates, the exhaust mass flow rate signals are used for controlling the partial flow dilution system to take a sample proportional to the exhaust mass flow rate. The quality of proportionality is checked by applying a regression analysis between sample and exhaust flow as described in Annex 4A, Appendix 1, paragraph 2.4.
Determination of the gaseous components
Calculation of mass emission
The mass of the pollutants Mgas (g/test) shall be determined by calculating the instantaneous mass emissions from the raw concentrations of the pollutants, the u values from Table 6 (see also paragraph 1.3.4.) and the exhaust mass flow, aligned for the transformation time and integrating the instantaneous values over the cycle. Preferably, the concentrations should be measured on a wet basis. If measured on a dry basis, the dry/wet correction as described here below shall be applied to the instantaneous concentration values before any further calculation is done.
Values of the coefficient u – wet for various exhaust components
Gas u conc
NOx 0.001587 ppm
CO 0.000966 ppm
HC 0.000479 ppm
CO2 15.19 per cent
The density of HC is based upon an average carbon to hydrogen ratio of 1:1.85.
The following formula shall be applied:
n
1 (in g/test)
M gas = ∑ u ⋅ conci ⋅ G ⋅
E
X
H
W
,
i
i =1 f
where:
u = ratio between density of exhaust component and density of
exhaust gas
conci = instantaneous concentration of the respective component in the
raw exhaust gas (ppm)
GEXHW, i= instantaneous exhaust mass flow (kg/s)
f = data sampling rate (Hz)
n = number of measurements
For the calculation of NOx, the humidity correction factor kH, as described here
below, shall be used.
Annex 4A - Appendix 3
The instantaneously measured concentration shall be converted to a wet basis
as described here below, if not already measured on a wet basisDry/wet correction
If the instantaneously measured concentration is measured on a dry basis, it shall be converted to a wet basis according to the following formulae: concwet = KW · concdry
where:
⎛ 1 ⎞ K W,r = ⎜ ⎟−K
W ⎝ 1 + 1.88 ⋅ 0.005 ⋅ (concCO + conc )⎠
C O with: 1.608 ⋅ H a K W2 = 1000 + (1.608 ⋅ H a ) where: concCO2= dry CO2 concentration (per cent) concCO= dry CO concentration (per cent) Ha = intake air humidity, (g water per kg dry air) 6.220 ⋅ Ra ⋅ pa Ha = p B − pa ⋅ Ra ⋅ 10 − 2 where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
NOx correction for humidity and temperature
As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for humidity and ambient air temperature with the factors given in the following formula: kH= 1 - 0.0182 ⋅ ( H a - 10.71) + 0.0045 ⋅ (T a - 298) with: Ta = temperature of the intake air, K Ha = humidity of the intake air, g water per kg dry air 6.220 ⋅ Ra ⋅ pa Ha = p B − pa ⋅ Ra ⋅ 10 − 2
Annex 4A - Appendix 3 where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa).
Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Calculation of the specific emissions
The specific emissions (g/kWh) shall be calculated for each individual component in the following way: (1 / 10) M gas,cold + (9 / 10) M gas,hot Individual Gas = (1 / 10)Wgas,cold + (9 / 10)Wgas,hot
where: Mgas,cold = total mass of gaseous pollutant over the cold start cycle (g) Mgas,hot = total mass of gaseous pollutant over the hot start cycle (g) Wact,cold = actual cycle work over the cold start cycle as determined in Annex 4A, paragraph 4.6.2. (kWh) Wact,hot = actual cycle work over the hot start cycle as determined in Annex 4A, paragraph 4.6.2. (kWh)
Particulate determination
Calculation of mass emission
The particulate masses MPT,cold and MPT,hot (g/test) shall be calculated by either of the following methods: M =
(a) M f M EDFW PT ⋅ M SAM 1000 where: MPT = MPT,cold for the cold start cycle MPT = MPT,hot for the hot start cycle Mf = particulate mass sampled over the cycle (mg) MEDFW = mass of equivalent diluted exhaust gas over the cycle (kg) MSAM = mass of diluted exhaust gas passing the particulate collection filters (kg) The total mass of equivalent diluted exhaust gas mass over the cycle shall be determined as follows: M
=
n ∑G ⋅ E D F W ,
EDFW i i =1 f G
=
G ⋅ qi E X H W ,
EDFW,i i
Annex 4A - Appendix 3
= GTOTW,i qi (GTOTW,i − GDILW,i )
where: GEDFW,i = instantaneous equivalent diluted exhaust mass flow rate (kg/s) GEXHW,i = instantaneous exhaust mass flow rate (kg/s) qi = instantaneous dilution ratio GTOTW,i = instantaneous diluted exhaust mass flow rate through dilution tunnel (kg/s) GDILW,i = instantaneous dilution air mass flow rate (kg/s) f = data sampling rate (Hz) n = number of measurements =
(b) Mf M PT rs ⋅1000
where: MPT = MPT,cold for the cold start cycle MPT = MPT,hot for the hot start cycle Mf = particulate mass sampled over the cycle (mg) rs = average sample ratio over the test cycle where: =
M SE M rs ⋅ SAM M EXHW M TOTW MSE = sampled exhaust mass over the cycle (kg) MEXHW = total exhaust mass flow over the cycle (kg) MSAM = mass of diluted exhaust gas passing the particulate collection filters (kg) MTOTW = mass of diluted exhaust gas passing the dilution tunnel (kg) Note: In case of the total sampling type system, MSAM and MTOTW are identical
Particulate correction factor for humidity
As the particulate emission of diesel engines depends on ambient air conditions, the particulate concentration shall be corrected for ambient air humidity with the factor kp given in the following formulae. =
kp (1 + 0.0133 ⋅ ( H a − 10.71))
Annex 4A - Appendix 3 where: Ha = humidity of the intake air in g water per kg dry air 6.220 ⋅ Ra ⋅ pa Ha = pB − pa ⋅ Ra ⋅ 10−2 where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Calculation of the specific emissions
The specific emissions (g/kWh) shall be calculated for in the following way: K 1
M PW
K pW
MP /
+ + 9 9 / / 1 1 0 0 ︵ ︶ ︵ ︶ P T =
⋅ ⋅ p , c o d0 l
T , c o l d
, h o t
T , h o t /
︵ ︶ act , cold ︵ ︶ act , hot
where: MPT,cold = particulate mass over the cold start cycle (g/test) MPT,hot = particulate mass over the hot start cycle (g/test) Kp, cold = humidity correction factor for particulate over the cold start cycle Kp, hot = humidity correction factor for particulate over the hot start cycle Wact, cold = actual cycle work over the cold start cycle as determined in paragraph 4.6.2. of Annex 4A, (kWh) Wact, hot = actual cycle work over the hot start cycle as determined in paragraph 4.6.2. of Annex 4A, (kWh)
Determination of gaseous and particulate components with a full flow dilution system For calculation of the emissions in the diluted exhaust gas, it is necessary to know the diluted exhaust gas mass flow rate. The total diluted exhaust gas flow over the cycle MTOTW (kg/test) shall be calculated from the measurement values over the cycle and the corresponding calibration data of the flow measurement device (V0 for PDP, KV for CFV, Cd for SSV): the corresponding methods described in paragraph 2.2.1. may be used. If the total sample mass of particulates (MSAM) and gaseous pollutants exceeds 0.5 per cent of the total CVS flow (MTOTW), the CVS flow shall be corrected for MSAM or the particulate sample flow shall be returned to the CVS prior to the flow measuring device.
Annex 4A - Appendix 3
Determination of the diluted exhaust gas flow
PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ±6 K over the cycle by using a heat exchanger, is as follows: MTOTW = 1.293 · V0 · NP · (pB - p1) · 273 / (101.3 · T) where: MTOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m3/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the test cell (kPa) p1 = pressure drop below atmospheric at the pump inlet (kPa) T = average temperature of the diluted exhaust gas at pump inlet over the cycle (K) If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: MTOTW,i = 1.293 · V0 · NP, i · (pB – p1) · 273 / (101.3 · T) where: NP, i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ±11 K over the cycle by using a heat exchanger, is as follows: MTOTW = 1.293 · t · Kv · pA / T0.5 where: MTOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = calibration coefficient of the critical flow venturi for standard conditions, pA = absolute pressure at venturi inlet (kPa) T = absolute temperature at venturi inlet (K) If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: MTOTW,i = 1.293 · Δti · KV · pA / T0.5
Annex 4A - Appendix 3
where: Δti = time interval(s) SSV-CVS system The calculation of the mass flow over the cycle is as follows if the temperature of the diluted exhaust is kept within ±11 K over the cycle by using a heat exchanger: M TOTW = 1.293 ⋅ QSSV ⋅ Δt
where:
⎡1 ⎛ 1 ⎞⎤ ( Q SSV = A 0 d 2 C d P A ⎢ r 1.4286 − r 1.7143 ⋅ ⎜ ) ⎟⎥ ⎜ 1 − β 4 r 1.4286 ⎟⎥ ⎢⎣ T ⎝ ⎠⎦ A0 = collection of constants and units conversions
⎛ 1 ⎞ ⎛ m 3 ⎞⎜ K 2 ⎟⎛ 1 ⎞ = 0.006111 in SI units ⎜⎜ ⎟⎟⎜ ⎟⎜ 2 ⎟ ⎝ min ⎠⎜ kPa ⎟⎝ mm ⎠ ⎝ ⎠ d = diameter of the SSV throat (m) Cd = discharge coefficient of the SSV pA = absolute pressure at venturi inlet (kPa) T = temperature at the venturi inlet (K) r = ratio of the SSV throat to inlet absolute, static pressure = ΔP 1− PA ß = ratio of the SSV throat diameter, d, to the inlet pipe inner d diameter = D If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle. In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows:
M TOTW,i = 1.293 ⋅ QSSV ⋅ Δti where:
⎡1 ⎛ ⎞⎤ Q SSV = A 0 d 2 C d P A x ⎢ (r 1.4286 − r 1.7143)⎜ 1 ⎟⎥ ⎢⎣ T ⎜ 4 1.4286 ⎟ ⎝1− β r ⎠⎥⎦ Δti = time interval (s)
Annex 4A - Appendix 3
The real time calculation shall be initialised with either a reasonable value for Cd, such as 0.98, or a reasonable value of Qssv. If the calculation is initialised with Qssv, the initial value of Qssv shall be used to evaluate Re. During all emissions tests, the Reynolds number at the SSV throat shall be in the range of Reynolds numbers used to derive the calibration curve developed in Appendix 2, paragraph 3.2.
NOx correction for humidity
As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for ambient air humidity with the factors given in the following formulae. kH= 1 - 0.0182 ⋅ ( H a - 10.71) + 0.0045 ⋅ (T a - 298) where: Ta = temperature of the air (K) Ha = humidity of the intake air (g water per kg dry air) 6.220 ⋅ Ra ⋅ pa Ha = pB − pa ⋅ Ra ⋅ 10−2 where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa). Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Calculation of the emission mass flow
Systems with constant mass flow
For systems with heat exchanger, the mass of the pollutants MGAS (g/test) shall be determined from the following equation: Mgas = u · conc · MTOTW where: u = ratio between density of the exhaust component and density of diluted exhaust gas, as reported in Table 6, paragraph 2.1.2.1. conc = average background corrected concentrations over the cycle from integration (mandatory for NOx and HC) or bag measurement (ppm) MTOTW = total mass of diluted exhaust gas over the cycle as determined in paragraph 2.2.1. (kg)
Annex 4A - Appendix 3
As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for ambient air humidity with the factor kH, as described in paragraph 2.2.2. Concentrations measured on a dry basis shall be converted to a wet basis in accordance with paragraph 1.3.2.
Determination of the background corrected concentrations
The average background concentration of the gaseous pollutants in the dilution air shall be subtracted from measured concentrations to get the net concentrations of the pollutants. The average values of the background concentrations can be determined by the sample bag method or by continuous measurement with integration. The following formula shall be used. conc = conce – concd · (1 – (1 / DF)) where: conc = concentration of the respective pollutant in the diluted exhaust gas, corrected by the amount of the respective pollutant contained in the dilution air (ppm) conce = concentration of the respective pollutant measured in the diluted exhaust gas (ppm) concd = concentration of the respective pollutant measured in the dilution air (ppm) DF = dilution factor The dilution factor shall be calculated as follows: D F =
13.4 c o n ce
- 4
+ (conceHC + conceCO ) ⋅ C O
Systems with flow compensation
For systems without heat exchanger, the mass of the pollutants MGAS (g/test) shall be determined by calculating the instantaneous mass emissions and integrating the instantaneous values over the cycle. Also, the background correction shall be applied directly to the instantaneous concentration value. The following formulae shall be applied: M =
n ∑ ((M ⋅ conc i ⋅ u ) − ( M TOTW ⋅ concd ⋅ (1 − ) ⋅ u )) T O T W ,
e ,
GAS i i =1 DF where: conce, i = instantaneous concentration of the respective pollutant measured in the diluted exhaust gas (ppm) concd = concentration of the respective pollutant measured in the dilution air (ppm) u = ratio between density of the exhaust component and density of diluted exhaust gas, as reported in Table 6, paragraph 2.1.2.1.
Annex 4A - Appendix 3
MTOTW, i = instantaneous mass of the diluted exhaust gas (paragraph 2.2.1.) (kg) MTOTW = total mass of diluted exhaust gas over the cycle (paragraph 2.2.1.) (kg) DF = dilution factor as determined in paragraph 2.2.3.1.1. As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for ambient air humidity with the factor kH, as described in paragraph 2.2.2.
Calculation of the specific emissions
The specific emissions (g/kWh) shall be calculated for each individual component in the following way: (1 / 10) M gas,cold + (9 / 10) M gas,hot Individual Gas = (1 / 10)Wgas,cold + (9 / 10)Wgas,hot
where: Mgas,cold = total mass of gaseous pollutant over the cold start cycle (g) Mgas,hot = total mass of gaseous pollutant over the hot start cycle (g) Wact,cold = actual cycle work over the cold start cycle as determined in paragraph 4.6.2. of Annex 4A (kWh) Wact,hot = actual cycle work over the hot start cycle as determined in paragraph 4.6.2. of Annex 4A. (kWh)
Calculation of the particulate emission
Calculation of the mass flow
The particulate masses MPT,cold and MPT,hot (g/test) shall be calculated as follows: M =
M f M TOTW PT ⋅ M SAM 1000
where: MPT = MPT,cold for the cold start cycle MPT = MPT,hot for the hot start cycle Mf = particulate mass sampled over the cycle (mg) MTOTW = total mass of diluted exhaust gas over the cycle as determined in paragraph 2.2.1. (kg) MSAM = mass of diluted exhaust gas taken from the dilution tunnel for collecting particulates (kg) and Mf = Mf,p + Mf,b, if weighed separately (mg) Mf,p = particulate mass collected on the primary filter (mg) Mf,b = particulate mass collected on the back-up filter (mg)
Annex 4A - Appendix 3 If a double dilution system is used, the mass of the secondary dilution air shall be subtracted from the total mass of the double diluted exhaust gas sampled through the particulate filters. MSAM = MTOT - MSEC where: MTOT = mass of double diluted exhaust gas through particulate filter (kg) MSEC = mass of secondary dilution air (kg) If the particulate background level of the dilution air is determined in accordance with paragraph 4.4.4. of Annex 4A, the particulate mass may be background corrected. In this case, the particulate masses MPT,cold and MPT,hot (g/test) shall be calculated as follows: M =
︵ Mf M 1 M PT − ( d ⋅ (1 − ))) ⋅ TOTW M SAM M DIL DF 1000
where: MPT = MPT,cold for the cold start cycle MPT = MPT,hot for the hot start cycle Mf, MSAM, MTOTW = see above MDIL = mass of primary dilution air sampled by background particulate sampler (kg) Md = mass of the collected background particulates of the primary dilution air (mg) DF = dilution factor as determined in paragraph 2.2.3.1.1.
Particulate correction factor for humidity
As the particulate emission of diesel engines depends on ambient air conditions, the particulate concentration shall be corrected for ambient air humidity with the factor kp given in the following formula. =
kp (1 + 0.0133 ⋅ ( H a − 10.71)) where: Ha = humidity of the intake air (g water per kg dry air) 6.220 ⋅ Ra ⋅ pa Ha = p B − pa ⋅ Ra ⋅ 10 − 2 where: Ra = relative humidity of the intake air (per cent) pa = saturation vapour pressure of the intake air (kPa) pB = total barometric pressure (kPa).
Annex 4A - Appendix 3
Note: Ha may be derived from relative humidity measurement, as described above, or from dewpoint measurement, vapour pressure measurement or dry/wet bulb measurement using the generally accepted formulae.
Calculation of the specific emissions
The specific emissions (g/kWh) shall be calculated for in the following way:
K 1
M PW
K pW
MP /
+ + 9 9 / / 1 1 0 0 ︵ ︶ ︵ ︶ P T = ⋅ ⋅
p , c1 o d0 l
T , c o l d
, h o t
T , h o t / ︵ ︶ act ,cold ︵ ︶ act , hot
where: MPT,cold = particulate mass over the cold start cycle of NRTC, (g/test) MPT,hot = particulate mass over the hot start cycle of NRTC, (g/test) Kp, cold = humidity correction factor for particulate over the cold start cycle Kp, hot = humidity correction factor for particulate over the hot start cycle Wact, cold = actual cycle work over the cold start cycle as determined in paragraph 4.6.2. of Annex 4A, (kWh) Wact, hot = actual cycle work over the hot start cycle as determined in paragraph 4.6.2. of Annex 4A, (kWh)
Annex 4A - Appendix 4
Annex 4A - Appendix 4
Analytical and sampling system
1.Gaseous and particulate sampling systems
Figure number Description
Exhaust gas analysis system for raw exhaust
Exhaust gas analysis system for dilute exhaust
Partial flow, isokinetic flow, suction blower control, fractional sampling
Partial flow, isokinetic flow, pressure blower control, fractional sampling
Partial flow, CO2 or NOx control, fractional sampling
Partial flow, CO2 or carbon balance, total sampling
Partial flow, single venturi and concentration measurement, fractional sampling
Partial flow, twin venturi or orifice and concentration measurement, fractional sampling
Partial flow, multiple tube splitting and concentration measurement, fractional sampling
Partial flow, flow control, total sampling
Partial flow, flow control, fractional sampling
Full flow, positive displacement pump or critical flow venturi, fractional sampling
Particulate sampling system
Dilution system for full flow system
Determination of the gaseous emissions
Paragraph 1.1.1. and Figures 2 and 3 contain detailed descriptions of the recommended sampling and analysing systems. Since various configurations can produce equivalent results, exact conformance with these figures is not required. Additional components such as instruments, valves, solenoids, pumps and switches may be used to provide additional information and coordinate the functions of the component systems. Other components which are not needed to maintain the accuracy on some systems may be excluded if their exclusion is based upon good engineering judgement.
Gaseous exhaust components CO, CO2, HC, NOx
An analytical system for the determination of the gaseous emissions in the raw or diluted exhaust gas is described based on the use of:
- HFID analyser for the measurement of hydrocarbons;
Annex 4A - Appendix 4
- NDIR analysers for the measurement of carbon monoxide and carbon dioxide;
- HCLD or equivalent analyser for the measurement of nitrogen oxide. For the raw exhaust gas (Figure 2), the sample for all components may be taken with one sampling probe or with two sampling probes located in close proximity and internally split to the different analysers. Care shall be taken that no condensation of exhaust components (including water and sulphuric acid) occurs at any point of the analytical system. For the diluted exhaust gas (Figure 3), the sample for the hydrocarbons shall be taken with another sampling probe than the sample for the other components. Care shall be taken that no condensation of exhaust components (including water and sulphuric acid) occurs at any point of the analytical system.
Determination of the particulates
Paragraphs 1.2.1. and 1.2.2. and Figures 4 to 15 contain detailed descriptions of the recommended dilution and sampling systems. Since various configurations can produce equivalent results, exact conformance with these figures is not required. Additional components such as instruments, valve, solenoids, pumps and switches may be used to provide additional information and coordinate the functions of the component systems. Other components which are not needed to maintain the accuracy on some systems may be excluded if their exclusion is based on good engineering judgement.
Dilution system
Partial flow dilution system (Figures 4 to 12) 1
A dilution system is described based on the dilution of a part of the exhaust stream. Splitting of the exhaust stream and the following dilution process may be done by different dilution system types. For subsequent collection of the particulates, the entire dilute exhaust gas or only a portion of the dilute exhaust
Figures 4 to 12 show many types of partial flow dilution systems, which normally can be used for the steady-state test (NRSC). But, because of very severe constraints of the transient tests, only those partial flow dilution systems (Figures 4 to 12) able to fulfill all the requirements quoted in paragraph 2.4. Appendix 1, Annex 4A - Partial flow dilution system specifications -, are accepted for the transient test (NRTC).
Annex 4A - Appendix 4
gas may be passed to the particulate sampling system (paragraph 1.2.2.,
Full flow dilution system (Figure 13)
A dilution system is described based upon the dilution of the total exhaust using the constant volume sampling (CVS) concept. The total volume of the mixture of exhaust and dilution air shall be measured. Either a PDP or a CFV or a SSV system may be used.
Annex 4A - Appendix 4
For subsequent collection of the particulates, a sample of the dilute exhaust gas is passed to the particulate sampling system (paragraph 1.2.2., Figures 14 and 15). If this is done directly, it is referred to as single dilution. If the sample is diluted once more in the secondary dilution tunnel, it is referred to as double dilution. This is useful, if the filter face temperature requirement cannot be met with single dilution. Although partly a dilution system, the double dilution system is described as a modification of a particulate sampling system in paragraph 1.2.2., (Figure 15), since it shares most of the parts with a typical particulate sampling system. The gaseous emissions may also be determined in the dilution tunnel of a full flow dilution system. Therefore, the sampling probes for the gaseous components are shown in Figure 13 but do not appear in the description list. The respective requirements are described in paragraph 1.1.1. Descriptions (Figure 13) — EP exhaust pipe The exhaust pipe length from the exit of the engine exhaust manifold, turbocharger outlet or after-treatment device to the dilution tunnel is required to be not more than 10 m. If the system exceeds 4 m in length, then all tubing in excess of 4 m shall be insulated, except for an in-line smoke-meter, if used. The radial thickness of the insulation shall be at least 25 mm. The thermal conductivity of the insulating material shall have a value no greater than 0.1 W/(m · K) measured at 673 K (400 °C). To reduce the thermal inertia of the exhaust pipe a thickness to diameter ratio of 0.015 or less is recommended. The use of flexible sections shall be limited to a length to diameter ratio of 12 or less.
Annex 4A - Appendix 4
Particulate sampling system (Figures 14 and 15)
The particulate sampling system is required for collecting the particulates on the particulate filter. In the case of total sampling partial flow dilution, which consists of passing the entire dilute exhaust sample through the filters, dilution (paragraph 1.2.1.1., Figures 7 and 11) and sampling system usually form an integral unit. In the case of fractional sampling partial flow dilution or full flow dilution, which consists of passing through the filters only a portion of the diluted exhaust, the dilution (paragraph 1.2.1.1, Figures 4, 5, 6, 8, 9, 10 and 12 and paragraph 1.2.1.2., Figure 13) and sampling systems usually form different units. In this Regulation, the double dilution system DDS (Figure 15) of a full flow dilution system is considered as a specific modification of a typical particulate sampling system as shown in Figure 14. The double dilution system includes all important parts of the particulate sampling system, like filter holders and sampling pump, and additionally some dilution features, like a dilution air supply and a secondary dilution tunnel. In order to avoid any impact on the control loops, it is recommended that the sample pump be running throughout the complete test procedure. For the single filter method, a bypass system shall be used for passing the sample through the sampling filters at the desired times. Interference of the switching procedure on the control loops shall be minimized.
Annex 4A - Appendix 4
Descriptions – Figures 14 and 15 — PSP particulate sampling probe (Figures 14 and 15) The particulate sampling probe shown in the figures is the leading section of the particulate transfer tube PTT. The probe:
- Shall be installed facing upstream at a point where the dilution air and exhaust gas are well mixed, i.e. on the dilution tunnel DT centre-line of the dilution systems (paragraph 1.2.1.), approximately 10 tunnel diameters downstream of the point where the exhaust enters the dilution tunnel);
- Shall be 12 mm in minimum inside diameter;
- May be heated to no greater than 325 K (52 °C) wall temperature by direct heating or by dilution air pre-heating, provided the air temperature does not exceed 325 K (52 °C) prior to the introduction of the exhaust in the dilution tunnel;
- May be insulated.
Particulate sampling system
PTT from dilution tunnel DT (figures 4 to 13) BV
FH
optional P FC3 from EGA or from PDP or FM3 from CFV or from GFUEL
A sample of the diluted exhaust gas is taken from the dilution tunnel DT of a partial flow or full flow dilution system through the particulate sampling probe PSP and the particulate transfer tube PTT by means of the sampling pump P. The sample is passed through the filter holder(s) FH that contain the particulate sampling filters. The sample flow rate is controlled by the flow controller FC3. If electronic flow compensation EFC (Figure 13) is used, the diluted exhaust gas flow is used as command signal for FC3.
Annex 4A - Appendix 4
1.Reserved
2.Reserved
3.Definitions, symbols and abbreviations
Definitions
See paragraph 2.1. of this Regulation
General symbols 1
Symbol Unit Term a0 - y intercept of the regression line a1 - Slope of the regression line αsp rad/s2 Derivative of the engine speed at the set point A/Fst - Stoichiometric air to fuel ratio c ppm, per cent Concentration (also in µmol/mol = ppm) vol D - Dilution factor d m Diameter E per cent Conversion efficiency e g/kWh Brake specific basis egas g/kWh Specific emission of gaseous components ePM g/kWh Specific emission of particulates ew g/kWh Weighted specific emission F F-test statistics F - Frequency of the regeneration event in terms of fraction of tests during which the regeneration occurs fa - Laboratory atmospheric factor kr - Multiplicative regeneration factor kDr - downward adjustment factor kUr - upward adjustment factor λ - Excess air ratio
Specific symbols are found in annexes.
Annex 4B
Symbol Unit Term L - Per cent torque Ma g/mol Molar mass of the intake air Me g/mol Molar mass of the exhaust Mgas g/mol Molar mass of gaseous components m kg Mass mgas g Mass of gaseous emissions over the test cycle mPM g Mass of particulate emissions over the test cycle n min-1 Engine rotational speed nhi min-1 High engine speed nlo min-1 Low engine speed P kW Power Pmax kW Maximum observed or declared power at the test speed under the test conditions (specified by the manufacturer) PAUX kW Declared total power absorbed by auxiliaries fitted for the test p kPa Pressure pa kPa Dry atmospheric pressure PF per cent Penetration fraction qmaw kg/s Intake air mass flow rate on wet basis qmdw kg/s Dilution air mass flow rate on wet basis qmdew kg/s Diluted exhaust gas mass flow rate on wet basis qmew kg/s Exhaust gas mass flow rate on wet basis qmf kg/s Fuel mass flow rate qmp kg/s Sample flow of exhaust gas into partial flow dilution system qV m³/s Volume flow rate RF - Response factor rd - Dilution ratio r2 - Coefficient of determination ρ kg/m³ Density σ - Standard deviation S kW Dynamometer setting SEE - Standard error of estimate of y on x T °C Temperature Ta K Absolute temperature T N·m Engine torque Tsp N·m Demanded torque with "sp" set point u - Ratio between densities of gas component and exhaust gas t s Time Δt s Time interval
Annex 4B
Symbol Unit Term t10 s Time between step input and 10 per cent of final reading t50 s Time between step input and 50 per cent of final reading t90 s Time between step input and 90 per cent of final reading V m3 Volume W kWh Work y Generic variable y Arithmetic mean
Subscripts abs Absolute quantity act Actual quantity air Air quantity amb Ambient quantity atm Atmospheric quantity cor Corrected quantity CFV Critical flow venturi denorm Denormalized quantity dry Dry quantity exp Expected quantity filter PM sample filter i Instantaneous measurement (e.g. 1 Hz) i An individual of a series idle Condition at idle in Quantity in leak Leak quantity max Maximum (peak) value meas Measured quantity min Minimum value mix Molar mass of air out Quantity out PDP Positive displacement pump ref Reference quantity SSV Subsonic venturi total Total quantity uncor Uncorrected quantity vac Vacuum quantity weight Calibration weight wet Wet quantity
Annex 4B
Symbols and abbreviations for the chemical components (used also as a subscript) See paragraph 2.2.2. of this Regulation
Abbreviations
See paragraph 2.2.3. of this Regulation
4.General requirements
The engine system shall be designed, constructed and assembled so as to enable it to comply with the provisions of this Regulation. The technical measures taken by the manufacturer shall be such as to ensure that the mentioned emissions are effectively limited, pursuant to this Regulation, throughout the useful life of the engine and under normal conditions of use. For this, engines shall meet the performance requirements of paragraph 5. when tested in accordance with the test conditions of paragraph 6. and the test procedure of paragraph 7.
5.Performance requirements
General requirements
Reserved 2
Emissions of gaseous and particulate pollutants
The pollutants are represented by:
(a) Oxides of nitrogen, NOx;
(b) Hydrocarbons, which may be expressed in the following ways:
(i) Total hydrocarbons, HC or THC;
(ii) Non-methane hydrocarbons, NMHC.
(c) Particulate matter, PM;
(d) Carbon monoxide, CO. The measured values of gaseous and particulate pollutants exhausted by the engine refer to the brake-specific emissions in grams per kilowatt-hour (g/kWh). Other system of units may be used with appropriate conversion. The emissions shall be determined on the duty cycles (steady-state and/or transient), as described in paragraph 7. The measurement systems shall meet the calibration and performance checks of paragraph 8. with measurement equipment of paragraph 9. Other systems or analysers may be approved by the Type Approval Authority if it is found that they yield equivalent results in accordance with paragraph 5.1.3.
The numbering of this annex is consistent with the numbering of the NRMM gtr 11. However, some sections of the NRMM gtr are not needed in this annex.
Annex 4B
Equivalency
The determination of system equivalency shall be based on a seven-sample pair (or larger) correlation study between the system under consideration and one of the systems of this annex. "Results" refer to the specific cycle weighted emissions value. The correlation testing is to be performed at the same laboratory, test cell, and on the same engine, and is preferred to be run concurrently. The equivalency of the sample pair averages shall be determined by F-test and t-test statistics as described in Annex 4B, Appendix A.2. obtained under the laboratory test cell and the engine conditions described above. Outliers shall be determined in accordance with ISO 5725 and excluded from the database. The systems to be used for correlation testing shall be subject to the approval by the Type Approval Authority.
Reserved
6.Test conditions
Laboratory test conditions
The absolute temperature (Ta) of the engine air at the inlet to the engine expressed in Kelvin, and the dry atmospheric pressure (ps), expressed in kPa shall be measured and the parameter fa shall be determined according to the following provisions. In multi-cylinder engines having distinct groups of intake manifolds, such as in a 'V' engine configuration, the average temperature of the distinct groups shall be taken. The parameter fa shall be reported with the test results. For better repeatability and reproducibility of the test results, it is recommended that the parameter fa be such that: 0.93 ≤ fa ≤ 1.07. Naturally aspirated and mechanically supercharged engines:
⎛ 99 ⎞ ⎛ T a ⎞0.7 fa = ⎜ ⎟ ⋅ ⎜ ⎜ p ⎟ ⎝ 298 ⎟⎠ (6-1) ⎝ s⎠ Turbocharged engines with or without cooling of the intake air: 0.7 ⎛ 99 ⎞ ⎛ Ta ⎞ 1.5
fa = ⎜ ⎟ ⋅⎜ ⎟ (6-2) ⎜p ⎟ ⎝ 298 ⎠ ⎝ s⎠ The temperature of intake air shall be maintained to (25 ± 5) °C, as measured upstream of any engine component. It is allowed to use:
(a) A shared atmospheric pressure meter as long as the equipment for handling intake air maintains ambient pressure, where the engine is tested, within ±1 kPa of the shared atmospheric pressure;
(b) A shared humidity measurement for intake air as long as the equipment for handling intake air maintains dew point, where the engine is tested, within ±0.5 °C of the shared humidity measurement.
Annex 4B
Engines with charge air cooling
(a) A charge-air cooling system with a total intake-air capacity that represents production engines' in-use installation shall be used. Any laboratory charge-air cooling system to minimize accumulation of condensate shall be designed. Any accumulated condensate shall be drained and all drains shall be completely closed before emission testing. The drains shall be kept closed during the emission test. Coolant conditions shall be maintained as follows:
(i) A coolant temperature of at least 20 °C shall be maintained at the inlet to the charge-air cooler throughout testing;
(ii) At the engine conditions specified by the manufacturer, the coolant flow rate shall be set to achieve an air temperature within ±5 °C of the value designed by the manufacturer after the charge-air cooler's outlet. The air-outlet temperature shall be measured at the location specified by the manufacturer. This coolant flow rate set point shall be used throughout testing. If the engine manufacturer does not specify engine conditions or the corresponding charge-air cooler air outlet temperature, the coolant flow rate shall be set at maximum engine power to achieve a charge-air cooler air outlet temperature that represents in-use operation;
(iii) If the engine manufacturer specifies pressure-drop limits across the charge-air cooling system, it shall be ensured that the pressure drop across the charge-air cooling system at engine conditions specified by the manufacturer is within the manufacturer's specified limit(s). The pressure drop shall be measured at the manufacturer's specified locations;
(b) The objective is to produce emission results that are representative of in- use operation. If good engineering judgment indicates that the specifications in this section would result in unrepresentative testing (such as overcooling of the intake air), more sophisticated set points and controls of charge-air pressure drop, coolant temperature, and flow rate may be used to achieve more representative results.
Engine power
Basis for emission measurement
The basis of specific emissions measurement is uncorrected power.
Auxiliaries to be fitted
During the test, the auxiliaries necessary for the engine operation shall be installed on the test bench according to the requirements of Annex 7.
Auxiliaries to be removed
Certain auxiliaries whose definition is linked with the operation of the machine and which may be mounted on the engine shall be removed for the test.
Annex 4B
Where auxiliaries cannot be removed, the power they absorb in the unloaded condition may be determined and added to the measured engine power (see note g in the table of Annex 7). If this value is greater than 3 per cent of the maximum power at the test speed it may be verified by the test authority. The power absorbed by auxiliaries shall be used to adjust the set values and to calculate the work produced by the engine over the test cycle.
Engine intake air
Introduction
The intake-air system installed on the engine or one that represents a typical in- use configuration shall be used. This includes the charge-air cooling and exhaust gas recirculation systems.
Intake air restriction
An engine air intake system or a test laboratory system shall be used presenting an air intake restriction within ±300 Pa of the maximum value specified by the manufacturer for a clean air cleaner at the rated speed and full load. The static differential pressure of the restriction shall be measured at the location and at the speed and torque set points specified by the manufacturer. If the manufacturer does not specify a location, this pressure shall be measured upstream of any turbocharger or exhaust gas recirculation system connection to the intake air system. If the manufacturer does not specify speed and torque points, this pressure shall be measured while the engine outputs maximum power.
Engine exhaust system
The exhaust system installed with the engine or one that represents a typical in- use configuration shall be used. For aftertreatment devices the exhaust restriction shall be defined by the manufacturer according to the aftertreatment condition (e.g. degreening/aging and regeneration/loading level). The exhaust system shall conform to the requirements for exhaust gas sampling, as set out in paragraph 9.3. An engine exhaust system or a test laboratory system shall be used presenting a static exhaust backpressure within 80 to 100 per cent of the maximum exhaust restriction at the engine speed and torque specified by the manufacturer. If the maximum restriction is 5 kPa or less, the set point shall be no less than 1.0 kPa from the maximum. If the manufacturer does not specify speed and torque points, this pressure shall be measured while the engine produces maximum power.
Engine with exhaust after-treatment system
If the engine is equipped with an exhaust after-treatment system, the exhaust pipe shall have the same diameter as found in-use for at least four pipe diameters upstream of the expansion section containing the after-treatment device. The distance from the exhaust manifold flange or turbocharger outlet to the exhaust after-treatment system shall be the same as in the vehicle configuration or within the distance specifications of the manufacturer. The exhaust backpressure or restriction shall follow the same criteria as above, and may be set with a valve. The after-treatment container may be removed during dummy tests and during engine mapping, and replaced with an equivalent container having an inactive catalyst support.
Annex 4B
The emissions measured on the test cycle shall be representative of the emissions in the field. In the case of an engine equipped with an exhaust after- treatment system that requires the consumption of a reagent, the reagent used for all tests shall be declared by the manufacturer. For engines equipped with exhaust after-treatment systems that are regenerated on an infrequent (periodic) basis, as described in paragraph 6.6.2., emission results shall be adjusted to account for regeneration events. In this case, the average emission depends on the frequency of the regeneration event in terms of fraction of tests during which the regeneration occurs. After-treatment systems with continuous regeneration according to paragraph 6.6.1. do not require a special test procedure.
Continuous regeneration
For an exhaust aftertreatment system based on a continuous regeneration process the emissions shall be measured on an aftertreatment system that has been stabilized so as to result in repeatable emissions behaviour. The regeneration process shall occur at least once during the NRTC hot start test or ramped-modal cycle (RMC) test and the manufacturer shall declare the normal conditions under which regeneration occurs (soot load, temperature, exhaust back-pressure, etc.). In order to demonstrate that the regeneration process is continuous, at least three NRTC hot start tests or ramped-modal cycle (RMC) tests shall be conducted. In case of NRTC hot start test, the engine shall be warmed up in accordance with paragraph 7.8.2.1., the engine be soaked according to paragraph 7.4.2. and the first NRTC hot start test be run. The subsequent NRTC hot start tests shall be started after soaking according to paragraph 7.4.2. During the tests, exhaust temperatures and pressures shall be recorded (temperature before and after the after-treatment system, exhaust back pressure, etc.). The aftertreatment system is considered to be satisfactory if the conditions declared by the manufacturer occur during the test during a sufficient time and the emission results do not scatter by more than ±25 per cent or 0.005 g/kWh, whichever is greater. If the exhaust aftertreatment has a security mode that shifts to a periodic (infrequent) regeneration mode, it shall be checked according to paragraph 6.6.2. For that specific case, the applicable emission limits could be exceeded and would not be weighted.
Infrequent (periodic) regeneration
This provision only applies for engines equipped with emission controls that are regenerated on a periodic basis. For engines which are run on the discrete mode cycle this procedure cannot be applied. The emissions shall be measured on at least three NRTC hot start tests or ramped-modal cycle (RMC) tests, one with and two without a regeneration event on a stabilized aftertreatment system. The regeneration process shall occur at least once during the NRTC or RMC test. If regeneration takes longer than one NRTC or RMC test, consecutive NRTC or RMC tests shall be run and emissions continued to be measured without shutting the engine off until regeneration is completed and the average of the tests shall be calculated. If regeneration is completed during any test, the test shall be continued over its entire length. The engine may be equipped with a switch capable of preventing or permitting the regeneration process provided this operation has no effect on the original engine calibration.
Annex 4B
The manufacturer shall declare the normal parameter conditions under which the regeneration process occurs (soot load, temperature, exhaust back-pressure, etc.). The manufacturer shall also provide the frequency of the regeneration event in terms of number of tests during which the regeneration occurs. The exact procedure to determine this frequency shall be agreed by the Type Approval Authority based upon good engineering judgement. For a regeneration test, the manufacturer shall provide an aftertreatment system that has been loaded. Regeneration shall not occur during this engine conditioning phase. As an option, the manufacturer may run consecutive NRTC hot start or RMC tests until the aftertreatment system is loaded. Emissions measurement is not required on all tests. Average emissions between regeneration phases shall be determined from the arithmetic mean of several approximately equidistant NRTC hot start or RMC tests. As a minimum, at least one hot NRTC or RMC as close as possible prior to a regeneration test and one hot NRTC or RMC immediately after a regeneration test shall be conducted.
During the regeneration test, all the data needed to detect regeneration shall be recorded (CO or NOx emissions, temperature before and after the after- treatment system, exhaust back pressure, etc.). During the regeneration process, the applicable emission limits may be exceeded. The test procedure is schematically shown in Figure 6.1.
Scheme of infrequent (periodic) regeneration with n number of measurements and nr number of measurements during regeneration
Annex 4B
The average specific emission rate related to hot start ew [g/kWh] shall be weighted as follows (see Figure 6.1):
n ⋅ e + nr ⋅ er ew = (6-3) n + nr where: n = number of tests in which regeneration does not occur, nr = number of tests in which regeneration occurs (minimum one test),
e = average specific emission from a test in which the regeneration does not occur [g/kWh]
er = average specific emission from a test in which the regeneration occurs [g/kWh] At the choice of the manufacturer and based on upon good engineering analysis, the regeneration adjustment factor kr, expressing the average emission rate, may be calculated either multiplicative or additive as follows: Multiplicative ew kUr = (upward adjustment factor) (6-4a) e ew kDr = (downward adjustment factor) (6-4b) er Additive
k Ur = ew − e (upward adjustment factor) (6-5)
kDr = ew − er (downward adjustment factor) (6-6)
Upward adjustment factors are multiplied with or added to measured emission rates for all tests in which the regeneration does not occur. Downward adjustment factors are multiplied with or added to measured emission rates for all tests in which the regeneration occurs. The occurrence of the regeneration shall be identified in a manner that is readily apparent during all testing. Where no regeneration is identified, the upward adjustment factor shall be applied. With reference to Annex 4B, Appendices A.7-8 on brake specific emission calculations, the regeneration adjustment factor:
(a) Shall be applied to the results of the weighted NRTC test and RMC tests;
(b) May be applied to the ramped modal cycles and cold NRTC, if a regeneration occurs during the cycle;
(c) May be extended to other members of the same engine family;
Annex 4B
(d) May be extended to other engine families using the same aftertreatment system with the prior approval of the Type Approval Authority based on technical evidence to be supplied by the manufacturer that the emissions are similar. The following options shall be considered:
(a) A manufacturer may elect to omit adjustment factors for one or more of its engine families (or configurations) because the effect of the regeneration is small, or because it is not practical to identify when regenerations occur. In these cases, no adjustment factor shall be used, and the manufacturer is liable for compliance with the emission limits for all tests, without regard to whether a regeneration occurs;
(b) Upon request by the manufacturer, the type approval or certification authority may account for regeneration events differently than is provided in sub-paragraph (a). However, this option only applies for events that occur extremely infrequently, and which cannot be practically addressed using the adjustment factors described in sub- paragraph (a).
Cooling system
An engine cooling system with sufficient capacity to maintain the engine, with its intake-air, oil, coolant, block and head temperatures, at normal operating temperatures prescribed by the manufacturer shall be used. Laboratory auxiliary coolers and fans may be used.
Lubricating oil
The lubricating oil shall be specified by the manufacturer and be representative of lubricating oil available in the market; the specifications of the lubricating oil used for the test shall be recorded and presented with the results of the test.
Specification of the reference fuel
The reference fuel is specified in Annex 6, Table 3. The fuel temperature shall be in accordance with the manufacturer's recommendations. The fuel temperature shall be measured at the inlet to the fuel injection pump or as specified by the manufacturer, and the location of measurement recorded.
Crankcase emissions
No crankcase emissions shall be discharged directly into the ambient atmosphere, with the following exception: engines equipped with turbochargers, pumps, blowers, or superchargers for air induction may discharge crankcase emissions to the ambient atmosphere if the emissions are added to the exhaust emissions (either physically or mathematically) during all emission testing. Manufacturers taking advantage of this exception shall install the engines so that all crankcase emission can be routed into the emissions sampling system. For the purpose of this paragraph, crankcase emissions that are routed into the exhaust upstream of exhaust aftertreatment during all operation are not considered to be discharged directly into the ambient atmosphere.
Annex 4B
Open crankcase emissions shall be routed into the exhaust system for emission measurement, as follows:
(a) The tubing materials shall be smooth-walled, electrically conductive, and not reactive with crankcase emissions. Tube lengths shall be minimized as far as possible;
(b) The number of bends in the laboratory crankcase tubing shall be minimized, and the radius of any unavoidable bend shall be maximized;
(c) The laboratory crankcase exhaust tubing shall meet the engine manufacturer's specifications for crankcase back pressure;
(d) The crankcase exhaust tubing shall connect into the raw exhaust downstream of any aftertreatment system, downstream of any installed exhaust restriction, and sufficiently upstream of any sample probes to ensure complete mixing with the engine's exhaust before sampling. The crankcase exhaust tube shall extend into the free stream of exhaust to avoid boundary-layer effects and to promote mixing. The crankcase exhaust tube's outlet may orient in any direction relative to the raw exhaust flow.
7.Test procedures
Introduction
This paragraph describes the determination of brake specific emissions of gaseous and particulate pollutants on engines to be tested. The test engine shall be the parent engine configuration for the engine family as specified in paragraph 5.2. A laboratory emission test consists of measuring emissions and other parameters for the test cycles specified in this annex. The following aspects are treated (in this Annex 4B):
(a) The laboratory configurations for measuring the brake specific emissions (paragraph 7.2.);
(b) The pre-test and post-test verification procedures (paragraph 7.3.);
(c) The test cycles (paragraph 7.4.);
(d) The general test sequence (paragraph 7.5.);
(e) The engine mapping (paragraph 7.6.);
(f) The test cycle generation (paragraph 7.7.);
(g) The specific test cycle running procedure (paragraph 7.8.).
Principle of emission measurement
To measure the brake-specific emissions the engine shall be operated over the test cycles defined in paragraph 7.4., as applicable. The measurement of brake- specific emissions requires the determination of the mass of pollutants in the exhaust (i.e. HC, NMHC, CO, NOx and PM) and the corresponding engine work.
Annex 4B
Mass of constituent
The total mass of each constituent shall be determined over the applicable test cycle by using the following methods:
Continuous sampling
In continuous sampling, the constituent's concentration is measured continuously from raw or dilute exhaust. This concentration is multiplied by the continuous (raw or dilute) exhaust flow rate at the emission sampling location to determine the constituent's flow rate. The constituent's emission is continuously summed over the test interval. This sum is the total mass of the emitted constituent.
Batch sampling
In batch sampling, a sample of raw or dilute exhaust is continuously extracted and stored for later measurement. The extracted sample shall be proportional to the raw or dilute exhaust flow rate. Examples of batch sampling are collecting diluted gaseous emissions in a bag and collecting PM on a filter. In principal the method of emission calculation is done as follows: the batch sampled concentrations are multiplied by the total mass or mass flow (raw or dilute) from which it was extracted during the test cycle. This product is the total mass or mass flow of the emitted constituent. To calculate the PM concentration, the PM deposited onto a filter from proportionally extracted exhaust shall be divided by the amount of filtered exhaust.
Combined sampling
Any combination of continuous and batch sampling is permitted (e.g. PM with batch sampling and gaseous emissions with continuous sampling). The following Figure 7.1 illustrates the two aspects of the test procedures for measuring emissions: the equipments with the sampling lines in raw and diluted exhaust gas and the operations requested to calculate the pollutant emissions in steady-state and transient test cycles (Figure 7.1).
Annex 4B
Test procedures for emission measurement
Note on Figure 7.1: The term "Partial flow PM sampling" includes the partial flow dilution to extract only raw exhaust with constant or varying dilution ratio.
Work determination
The work shall be determined over the test cycle by synchronously multiplying speed and brake torque to calculate instantaneous values for engine brake power. Engine brake power shall be integrated over the test cycle to determine total work.
Verification and calibration
Pre-test procedures
Preconditioning
To achieve stable conditions, the sampling system and the engine shall be preconditioned before starting a test sequence as specified in paragraphs 7.3. and 7.4. The preconditioning for cooling down the engine in view of a cold start transient test is specially indicated in paragraph 7.4.2.
Verification of HC contamination
If there is any presumption of an essential HC contamination of the exhaust gas measuring system, the contamination with HC may be checked with zero gas and the hang-up may then be corrected. If the amount of contamination of the measuring system and the background HC system has to be checked, it shall be conducted within 8 hours of starting each test-cycle. The values shall be recorded for later correction. Before this check, the leak check has to be performed and the FID analyser has to be calibrated.
Annex 4B
Preparation of measurement equipment for sampling
The following steps shall be taken before emission sampling begins:
(a) Leak checks shall be performed within 8 hours prior to emission sampling according to paragraph 8.1.8.7.;
(b) For batch sampling, clean storage media shall be connected, such as evacuated bags or tare-weighed filters;
(c) All measurement instruments shall be started according to the instrument manufacturer's instructions and good engineering judgment;
(d) Dilution systems, sample pumps, cooling fans, and the data-collection system shall be started;
(e) The sample flow rates shall be adjusted to desired levels, using bypass flow, if desired;
(f) Heat exchangers in the sampling system shall be pre-heated or pre- cooled to within their operating temperature ranges for a test;
(g) Heated or cooled components such as sample lines, filters, chillers, and pumps shall be allowed to stabilize at their operating temperatures;
(h) Exhaust dilution system flow shall be switched on at least 10 minutes before a test sequence;
(i) Calibration of gas analysers and zeroing of continuous analysers shall be carried out according to the procedure of the next paragraph 7.3.1.4.;
(j) Any electronic integrating devices shall be zeroed or re-zeroed, before the start of any test interval.
Calibration of gas analysers
Appropriate gas analyser ranges shall be selected. Emission analysers with automatic or manual range switching are allowed. During a ramped modal or a NRTC test and during a sampling period of a gaseous emission at the end of each mode for discrete mode testing, the range of the emission analysers may not be switched. Also the gains of an analyser's analogue operational amplifier(s) may not be switched during a test cycle. All continuous analysers shall be zeroed and spanned using internationally- traceable gases that meet the specifications of paragraph 9.5.1. FID analysers shall be spanned on a carbon number basis of one (C1).
PM filter preconditioning and tare weighing
The procedures for PM filter preconditioning and tare weighing shall be followed according to paragraph 8.2.3.
Post-test procedures
The following steps shall be taken after emission sampling is complete:
Annex 4B
Verification of proportional sampling
For any proportional batch sample, such as a bag sample or PM sample, it shall be verified that proportional sampling was maintained according to paragraph 8.2.1. For the single filter method and the discrete steady-state test cycle, effective PM weighing factor shall be calculated. Any sample that does not fulfil the requirements of paragraph 8.2.1. shall be voided.
Post-test PM conditioning and weighing
Used PM sample filters shall be placed into covered or sealed containers or the filter holders shall be closed, in order to protect the sample filters against ambient contamination. Thus protected, the loaded filters have to be returned to the PM-filter conditioning chamber or room. Then the PM sample filters shall be conditioned and weighted accordingly to paragraph 8.2.4. (PM filter post- conditioning and total weighing procedures).
Analysis of gaseous batch sampling
As soon as practical, the following shall be performed:
(a) All batch gas analysers shall be zeroed and spanned no later than 30 minutes after the test cycle is complete or during the soak period if practical to check if gaseous analysers are still stable;
(b) Any conventional gaseous batch samples shall be analysed no later than 30 minutes after the hot-start test cycle is complete or during the soak period;
(c) The background samples shall be analysed no later than 60 minutes after the hot-start test cycle is complete.
Drift verification
After quantifying exhaust gases, drift shall be verified as follows:
(a) For batch and continuous gas analysers, the mean analyser value shall be recorded after stabilizing a zero gas to the analyser. Stabilization may include time to purge the analyser of any sample gas, plus any additional time to account for analyser response;
(b) The mean analyser value shall be recorded after stabilizing the span gas to the analyser. Stabilization may include time to purge the analyser of any sample gas, plus any additional time to account for analyser response;
(c) These data shall be used to validate and correct for drift as described in paragraph 8.2.2.
Test cycles
The following duty cycles apply:
(a) For variable-speed engines, the 8-mode test cycle or the corresponding ramped modal cycle, and the transient cycle NRTC as specified in Annex 5;
(b) For constant-speed engines, the 5-mode test cycle or the corresponding ramped modal cycle as specified in Annex 5.
Annex 4B
Steady-state test cycles
Steady-state test cycles are specified in Annex 5 as a list of discrete modes (operating points), where each operating point has one value of speed and one value of torque. A steady-state test cycle shall be measured with a warmed up and running engine according to manufacturer's specification. A steady-state test cycle may be run as a discrete-mode cycle or a ramped-modal cycle, as explained in the following paragraphs.
Steady-state discrete mode test cycles
The steady-state discrete 8-mode test cycle consists of eight speed and load modes (with the respective weighing factor for each mode) which cover the typical operating range of variable speed engines. The cycle is shown in Annex 5. The steady-state discrete 5-mode constant-speed test cycle consists of five load modes (with the respective weighing factor for each mode) all at rated speed which cover the typical operating range of constant speed engines. The cycle is shown in Annex 5.
Steady-state ramped test cycles
The ramped modal test cycles (RMC) are hot running cycles where emissions shall be started to be measured after the engine is started, warmed up and running as specified in paragraph 7.8.2.1. The engine shall be continuously controlled by the test bed control unit during the RMC test cycle. The gaseous and particulate emissions shall be measured and sampled continuously during the RMC test cycle in the same way as in a transient cycle. In case of the 5-mode test cycle the RMC consists of the same modes in the same order as the corresponding discrete steady-state test cycle. For the 8-mode test cycle the RMC has one mode more (split idle mode) and the mode sequence is not the same as the corresponding steady-state discrete mode cycle, in order to avoid extreme changes in the after-treatment temperature. The length of the modes shall be selected to be equivalent to the weighing factors of the corresponding discrete steady-state test cycle. The change in engine speed and load from one mode to the next one has to be linearly controlled in a time of 20 ± 1 s. The mode change time is part of the new mode (including the first mode).
Transient test cycle (NRTC)
The Non-Road Transient Cycle (NRTC) is specified in Annex 5 as a second- by-second sequence of normalized speed and torque values. In order to perform the test in an engine test cell, the normalized values shall be converted to their equivalent reference values for the individual engine to be tested, based on specific speed and torque values identified in the engine-mapping curve. The conversion is referred to as denormalization, and the resulting test cycle is the reference NRTC test cycle of the engine to be tested (see paragraph 7.7.2.). A graphical display of the normalized NRTC dynamometer schedule is shown in Annex 5.
Annex 4B
The transient test cycle shall be run twice (see paragraph 7.8.3.):
(a) As cold start after the engine and aftertreatment systems have cooled down to room temperature after natural engine cool down, or as cold start after forced cool down and the engine, coolant and oil temperatures, aftertreatment systems and all engine control devices are stabilized between 20 and 30 °C. The measurement of the cold start emissions shall be started with the start of the cold engine;
(b) Hot soak period — Immediately upon completion of the cold start phase, the engine shall be conditioned for the hot start by a 20 minutes ± 1 minute hot soak period;
(c) The hot-start shall be started immediately after the soak period with the cranking of the engine. The gaseous analysers shall be switched on at least 10 s before the end of the soak period to avoid switching signal peaks. The measurement of emissions shall be started in parallel with the start of the hot start phase including the cranking of the engine. Brake specific emissions expressed in (g/kWh) shall be determined by using the procedures of this section for both the cold and hot start test cycles. Composite weighted emissions shall be computed by weighing the cold start results by 10 per cent and the hot start results by 90 per cent as detailed in Annex 4B Appendices A.7-A.8.
General test sequence
To measure engine emissions the following steps have to be performed:
(a) The engine test speeds and test loads have to be defined for the engine to be tested by measuring the max torque (for constant speed engines) or max torque curve (for variable speed engines) as function of the engine speed;
(b) Normalized test cycles have to be denormalized with the torque (for constant speed engines) or speeds and torques (for variable speed engines) found in the previous sub-paragraph (a) of paragraph 7.5.;
(c) The engine, equipment, and measurement instruments shall be prepared for the following emission test or test series (cold and hot cycle) in advance;
(d) Pre-test procedures shall be performed to verify proper operation of certain equipment and analysers. All analysers have to be calibrated. All pre-test data shall be recorded;
(e) The engine shall be started (NRTC) or kept running (steady-state cycles) at the beginning of the test cycle and the sampling systems shall be started at the same time;
(f) Emissions and other required parameters shall be measured or recorded during sampling time (for NRTC and steady-state ramped modal cycles throughout the whole test cycle;
(g) Post-test procedures shall be performed to verify proper operation of certain equipment and analysers;
Annex 4B
(h) PM filter(s) shall be pre-conditioned, weighed (empty weight), loaded, re-conditioned, again weighed (loaded weight) and then samples shall be evaluated according to pre- (paragraph 7.3.1.5.) and post-test (paragraph 7.3.2.2.) procedures;
(i) Emission test results shall be evaluated. The following diagram gives an overview about the procedures needed to conduct NRMM test cycles with measuring exhaust engine emissions. Test sequence
Steady-state discrete & ramped Transient NRTC
If transient cycle If transient cycle and is not applied. steady-state are applied. Generation engine map (max. torque curve)
Defining steady-state test cycle Generate reference test cycle
Run one or more practice cycle as necessary to check engine/test
Natural or forced cool down
Ready all systems for sampling (analyser calibration included) & data collection
Warm-up engine
Exhaust emission test Cold start exhaust emission phase
Hot soak
Hot start exhaust emission phase
1) Data collection 2) Post-test procedures 3) Evaluations
Emissions calculation A.7.-A.8.
Annex 4B
Engine starting, and restarting
Engine start
The engine shall be started:
(a) As recommended in the owner's manual using a production starter motor or air-start system and either an adequately charged battery, a suitable power supply or a suitable compressed air source; or
(b) By using the dynamometer to crank the engine until it starts. Typically motor the engine within ±25 per cent of its typical in-use cranking speed or start the engine by linearly increasing the dynamometer speed from zero to 100 min-1 below low idle speed but only until the engine starts. Cranking shall be stopped within 1 s of starting the engine. If the engine does not start after 15 s of cranking, cranking shall be stopped and the reason for the failure to start determined, unless the owner's manual or the service-repair manual describes a longer cranking time as normal.
Engine stalling
(a) If the engine stalls anywhere during the cold start test of the NRTC, the test shall be voided;
(b) If the engine stalls anywhere during the hot start test of the NRTC, the test shall be voided. The engine shall be soaked according to paragraph 7.8.3., and the hot start test repeated. In this case, the cold start test does not need to be repeated;
(c) If the engine stalls anywhere during the steady-state cycle (discrete or ramped), the test shall be voided and be repeated beginning with the engine warm-up procedure. In the case of PM measurement utilizing the multifilter method (one sampling filter for each operating mode), the test shall be continued by stabilizing the engine at the previous mode for engine temperature conditioning and then initiating measurement with the mode where the engine stalled.
Engine mapping
Before starting the engine mapping, the engine shall be warmed up and towards the end of the warm up it shall be operated for at least 10 minutes at maximum power or according to the recommendation of the manufacturer and good engineering judgment in order to stabilize the engine coolant and lube oil temperatures. When the engine is stabilized, the engine mapping shall be performed. Except constant speed engines, engine mapping shall be performed with fully open fuel lever or governor using discrete speeds in ascending order. The minimum and maximum mapping speeds are defined as follows: Minimum mapping speed = warm idle speed Maximum mapping speed = nhi x 1.02 or speed where max torque drops off to zero, whichever is smaller. Where nhi is the high speed, defined as the highest engine speed where 70 per cent of the maximum power is delivered.
Annex 4B
If the highest speed is unsafe or unrepresentative (e.g., for ungoverned engines), good engineering judgment shall be used to map up to the maximum safe speed or the maximum representative one.
Engine mapping for steady-state 8-mode cycle
In the case of engine mapping for the steady-state 8-mode cycle (only for engines which have not to run the NRTC cycle), good engineering judgment shall be used to select a sufficient number (20 to 30) of evenly spaced set- points. At each setpoint, speed shall be stabilized and torque allowed to stabilize at least for 15 seconds. The mean speed and torque shall be recorded at each set-point. Linear interpolation shall be used to determine the 8-mode test speeds and torques if needed. If the derived test speeds and loads do not deviate for more than ±2.5 per cent from the speeds and torques indicated by the manufacturer, the manufacturer defined speeds and loads shall be applied. When engines shall be run on the NRTC too, then the NRTC engine mapping curve shall be used to determine steady-state test speeds and torques.
Engine mapping for NRTC cycle
The engine mapping shall be performed according to the following procedure:
(a) The engine shall be unloaded and operated at idle speed:
(i) For engines with a low-speed governor, the operator demand shall be set to the minimum, the dynamometer or another loading device shall be used to target a torque of zero on the engine's primary output shaft and the engine shall be allowed to govern the speed. This warm idle speed shall be measured;
(ii) For engines without a low-speed governor, the dynamometer shall be set to target a torque of zero on the engine's primary output shaft, and the operator demand shall be set to control the speed to the manufacturer-declared lowest engine speed possible with minimum load (also known as manufacturer-declared warm idle speed);
(iii) The manufacturer declared idle torque may be used for all variable-speed engines (with or without a low-speed governor), if a nonzero idle torque is representative of in-use operation.
(b) Operator demand shall be set to maximum and engine speed shall be controlled to between warm idle and 95 per cent of its warm idle speed. For engines with reference duty cycles, which lowest speed is greater than warm idle speed, the mapping may be started at between the lowest reference speed and 95 per cent of the lowest reference speed;
(c) The engine speed shall be increased at an average rate of 8 ± 1 min-1/s or the engine shall be mapped by using a continuous sweep of speed at a constant rate such that it takes 4 to 6 min to sweep from minimum to maximum mapping speed. The mapping speed range shall be started between warm idle and 95 per cent of warm idle and ended at the highest speed above maximum power at which less than 70 per cent of maximum power occurs. If this highest speed is unsafe or unrepresentative (e.g., for ungoverned engines), good engineering judgment shall be used to map up to the maximum safe speed or the maximum representative speed. Engine speed and torque points shall be recorded at a sample rate of at least 1 Hz;
Annex 4B
(d) If a manufacturer believes that the above mapping techniques are unsafe or unrepresentative for any given engine, alternate mapping techniques may be used. These alternate techniques shall satisfy the intent of the specified mapping procedures to determine the maximum available torque at all engine speeds achieved during the test cycles. Deviations from the mapping techniques specified in this paragraph for reasons of safety or representativeness shall be approved by the Type Approval Authority along with the justification for their use. In no case, however, the torque curve shall be run by descending engine speeds for governed or turbocharged engines;
(e) An engine need not be mapped before each and every test cycle. An engine shall be remapped if:
(i) An unreasonable amount of time has transpired since the last map, as determined by good engineering judgement; or
(ii) Physical changes or recalibrations have been made to the engine which potentially affect engine performance; or
(iii) The atmospheric pressure near the engine's air inlet is not within ±5 kPa of the value recorded at the time of the last engine map.
Engine mapping for constant-speed engines:
(a) The engine may be operated with a production constant-speed governor or a constant-speed governor maybe simulated by controlling engine speed with an operator demand control system. Either isochronous or speed-droop governor operation shall be used, as appropriate;
(b) With the governor or simulated governor controlling speed using operator demand, the engine shall be operated at no-load governed speed (at high speed, not low idle) for at least 15 s;
(c) The dynamometer shall be used to increase torque at a constant rate. The map shall be conducted such that it takes 2 to 4 min to sweep from no-load governed speed to the maximum torque. During the engine mapping actual speed and torque shall be recorded with at least 1 Hz;
(d) In case of a gen-set engine to be used for 50 Hz and 60 Hz power generation (for example 1,500 and 1,800 min-1) engine has to be tested in both constant speeds separately. For constant speed engines good engineering judgment shall be used to apply other methods to record max torque and power at the defined operating speed(s).
Test cycle generation
Generation of steady-state test cycles
Rated speed
For engines that are tested with the steady state and also the transient schedule, the denormalization speed shall be calculated according to the transient procedure (paragraphs 7.6.2. and 7.7.2.1. and Figure 7.3.).
Annex 4B
If the calculated denormalization speed (ndenorm) is within ±2.5 per cent of the denormalization speed as declared by the manufacturer, the declared denormalization speed (ndenorm) may be used for the emission test. If the tolerance is exceeded, the calculated denormalization speed (ndenorm) shall be used for the emissions test. In case of the steady state cycle the calculated denormalization speed (ndenorm) is tabled as rated speed. For engines that are not tested with the transient schedule, the rated speed of tables in Annex 5 for the 8-mode discrete and the derived ramped mode cycle shall be calculated according to the procedure (paragraphs 7.6.1. and 7.7.2.1. and Figure 7.3.). The rated speed is defined in paragraph 3.1.53.
Generation of steady-state 8-mode test cycle (discrete and ramp modal)
The intermediate speed shall be determined from the calculations according to its definition (see paragraph 3.1.32.). The engine setting for each test mode shall be calculated using the formula: ⎛ L ⎞ S = ⎜ ( Pmax + PAUX ) ⋅ ⎟ − PAUX (7-1) ⎝ 100 ⎠ where: S = dynamometer setting in kW Pmax = maximum observed or declared power at the test speed under the test conditions (specified by the manufacturer) in kW PAUX = declared total power absorbed by auxiliaries fitted for the test (see paragraph 6.3.) at the test speed in kW L = per cent torque During the test cycle, the engine shall be operated at the engine speeds and torques that are defined in Annex 5. The maximum mapping torque values at the specified test speeds shall be derived from the mapping curve (see paragraph 7.6.1. or 7.6.2.). "Measured" values are either directly measured during the engine mapping process or they are determined from the engine map. "Declared" values are specified by the manufacturer. When both measured and declared values are available, declared values may be used instead of torques if they don't deviate more than ±2.5 per cent. Otherwise, measured torques derived from the engine mapping shall be used.
Generation of steady-state 5-mode test cycle (discrete and ramp modal)
During the test cycle, the engine shall be operated at the engine speeds and torques that are defined in Annex 5. The maximum mapping torque value at the specified rated speed (see paragraph 7.7.1.1.) shall be used to generate the 5-mode test cycle. A warm minimum torque that is representative of in-use operation may be declared. For example, if the engine is typically connected to a machine that does not operate below a certain minimum torque, this torque may be declared and used for cycle generation. When both measured and declared values are available for the maximum test torque for cycle generation, the declared value may be used instead of the measured value if it is within 95 to 100 per cent of the measured value.
Annex 4B
The torque figures are percentage values of the torque corresponding to the prime power 3 rating. The prime power is defined as the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals and under the stated ambient conditions. The maintenance shall be carried out as prescribed by the manufacturer.
Generation of transient test cycle (NRTC denormalization)
Annex 5 defines applicable test cycles in a normalized format. A normalized test cycle consists of a sequence of paired values for speed and torque per cent. Normalized values of speed and torque shall be transformed using the following conventions:
(a) The normalized speed shall be transformed into a sequence of reference speeds, nref, according to paragraph 7.7.2.2.;
(b) The normalized torque is expressed as a percentage of the mapped torque at the corresponding reference speed. These normalized values shall be transformed into a sequence of reference torques, Tref, according to paragraph 7.7.2.3.;
(c) The reference speed and reference torque values expressed in coherent units are multiplied to calculate the reference power values.
Denormalization speed (ndenorm)
The denormalization speed (ndenorm) is selected to equal the 100 per cent normalized speed values specified in the engine dynamometer schedule of Annex 5. The reference engine cycle resulting from denormalization to the reference speed, depends on the selection of the proper denormalization speed (ndenorm). For the calculation of the denormalization speed (ndenorm), obtained from the measured mapping curve, either of the following equivalent formulations can be used in agreement with the Type Approval Authorities:
(a) ndenorm = nlo + 0.95 · (nhi – nlo) (7-2) where: ndenorm = denormalization speed nhi = high speed (see paragraph 3.1.30.) nlo = low speed (see paragraph 3.1.34.)
(b) ndenorm corresponding to the longest vector defined as:
ndenorm = ni at the maximum of ( nnorm i + Pnormi ) (7-3)
where: i = an indexing variable that represents one recorded value of an engine map nnormi = an engine speed normalized by dividing it by nPmax. Pnormi = an engine power normalized by dividing it by Pmax.
For further understanding of the prime power definition, see figure 2 of ISO 8528-1:1993(E) standard.
Annex 4B
Note that if multiple maximum values are found, the denormalization speed (ndenorm) should be taken as the lowest speed of all points with the same maximum sum of squares. A higher declared speed may be used if the length of the vector at the declared speed is within 2 per cent of the length of the vector at the measured value. If the falling part of the full load curve has a very steep edge, this may cause problems to drive the 105 per cent speeds of the NRTC test cycle correctly. In this case it is allowed with previous agreement with type approval or certification authorities, to reduce the denormalization speed (ndenorm) slightly (maximum 3 per cent) in order to make correct driving of the NRTC possible. If the measured denormalization speed (ndenorm) is within ±3 per cent of the denormalization speed as declared by the manufacturer, the declared denormalization speed (ndenorm) may be used for the emissions test. If the tolerance is exceeded, the measured denormalization speed (ndenorm) shall be used for the emissions test.
Denormalization of engine speed
The engine speed shall be denormalized using the following equation: %speed ⋅ (ndenorm − nidle ) (7-4) nref = + nidle where: nref = reference speed ndenorm = denormalization speed nidle = idle speed %speed = tabled NRTC normalized speed
Denormalization of engine torque
The torque values in the engine dynamometer schedule of Annex 5 paragraph 1.3. are normalized to the maximum torque at the respective speed. The torque values of the reference cycle shall be denormalized, using the mapping curve determined according to paragraph 7.6.2., as follows: %torque ⋅ max.torque (7-5) Tref = for the respective reference speed as determined in paragraph 7.7.2.2.
Example of denormalization procedure
As an example, the following test point shall be denormalized: %speed = 43 per cent %torque = 82 per cent Given the following values: ndenorm = 2200 min-1 nidle = 600 min-1 results in
Annex 4B
43 ⋅ ( 2200 − 600 ) nref= + 600 = 1288min −1 With the maximum torque of 700 Nm observed from the mapping curve at 1288 min-1 82 × 700 Tref= = 574Nm
Specific test cycle running procedure
Emission test sequence for discrete steady-state test cycles
Engine warming-up for steady state discrete-mode test cycles
For preconditioning the engine shall be warmed up according to the recommendation of the manufacturer and good engineering judgment. Before emission sampling can start, the engine shall be running until engine temperatures (cooling water and lube oil) have been stabilized (normally at least 10 minutes) on mode 1 (100 per cent torque and rated speed for the 8-mode test cycle and at rated or nominal constant engine speed and 100 per cent torque for the 5-mode test cycle). Immediately from this engine conditioning point, the test cycle measurement starts. Pre-test procedure according to paragraph 7.3.1. shall be performed, including analyser calibration.
Performing discrete-mode test cycles
(a) The test shall be performed in ascending order of mode numbers as set out for the test cycle (see Annex 5);
(b) Each mode has a mode length of at least 10 minutes. In each mode the engine shall be stabilized for at least 5 minutes and emissions shall be sampled for 1-3 minutes for gaseous emissions at the end of each mode. Extended time of sampling is permitted to improve the accuracy of PM sampling; The mode length shall be recorded and reported.
(c) The particulate sampling may be done either with the single filter method or with the multiple filter method. Since the results of the methods may differ slightly, the method used shall be declared with the results; For the single filter method the modal weighing factors specified in the test cycle procedure and the actual exhaust flow shall be taken into account during sampling by adjusting sample flow rate and/or sampling time, accordingly. It is required that the effective weighing factor of the PM sampling is within ±0.003 of the weighing factor of the given mode; Sampling shall be conducted as late as possible within each mode. For the single filter method, the completion of particulate sampling shall be coincident within ±5 s with the completion of the gaseous emission measurement. The sampling time per mode shall be at least 20 s for the single filter method and at least 60 s for the multifilter method. For systems without bypass capability, the sampling time per mode shall be at least 60 s for single and multiple filter methods;
Annex 4B
(d) The engine speed and load, intake air temperature, fuel flow and air or exhaust gas flow shall be measured for each mode at the same time interval which is used for the measurement of the gaseous concentrations; Any additional data required for calculation shall be recorded.
(e) If the engine stalls or the emission sampling is interrupted at any time after emission sampling begins for a discrete mode and the single filter method, the test shall be voided and be repeated beginning with the engine warm-up procedure. In the case of PM measurement utilizing the multifilter method (one sampling filter for each operating mode), the test shall be continued by stabilizing the engine at the previous mode for engine temperature conditioning and then initiating measurement with the mode where the engine stalled;
(f) Post-test procedures according to paragraph 7.3.2. shall be performed.
Validation criteria
During each mode of the given steady-state test cycle after the initial transition period, the measured speed shall not deviate from the reference speed for more than ±1 per cent of rated speed or ±3 min-1, whichever is greater except for idle which shall be within the tolerances declared by the manufacturer. The measured torque shall not deviate from the reference torque for more than ±2 per cent of the maximum torque at the test speed.
Ramped modal test cycles
Engine warming-up
Before starting the steady-state ramped modal test cycles (RMC), the engine shall be warmed-up and running until engine temperatures (cooling water and lube oil) have been stabilized on 50 per cent speed and 50 per cent torque for the RMC test cycle (derived from the 8-mode test cycle) and at rated or nominal engine speed and 50 per cent torque for the RMC test cycle (derived from 5-mode test cycle). Immediately after this engine conditioning procedure, engine speed and torque shall be changed in a linear ramp of 20 ± 1 s to the first mode of the test. In between 5 to 10 s after the end of the ramp, the test cycle measurement shall start.
Performing a ramped modal test cycle
The ramped modal cycles derived from 8-mode and 5-mode test cycle are shown in Annex 5. The engine shall be operated for the prescribed time in each mode. The transition from one mode to the next shall be done linearly in 20 s ± 1 s following the tolerances prescribed in paragraph 7.8.2.4. (see Annex 5). For ramped modal cycles, reference speed and torque values shall be generated at a minimum frequency of 1 Hz and this sequence of points shall be used to run the cycle. During the transition between modes, the denormalized reference speed and torque values shall be linearly ramped between modes to generate reference points. The normalized reference torque values shall not be linearly ramped between modes and then denormalized. If the speed and torque ramp runs through a point above the engine's torque curve, it shall be continued to command the reference torques and it shall be allowed for the operator demand to go to maximum.
Annex 4B
Over the whole RMC test cycle (during each mode and including the ramps between the modes), the concentration of each gaseous pollutant shall be measured and the PM be sampled. The gaseous pollutants may be measured raw or diluted and be recorded continuously; if diluted, they can also be sampled into a sampling bag. The particulate sample shall be diluted with conditioned and clean air. One sample over the complete test procedure shall be taken, and collected on a single PM sampling filter. For calculation of the brake specific emissions, the actual cycle work shall be calculated by integrating actual engine power over the complete cycle.
Emission test sequence:
(a) Execution of the RMC, sampling exhaust gases, recording data, and integrating measured values shall be started simultaneously;
(b) Speed and torque shall be controlled to the first mode in the test cycle;
(c) If the engine stalls anywhere during the RMC execution, the test shall be voided. The engine shall be pre-conditioned and the test repeated;
(d) At the end of the RMC, sampling shall be continued, except for PM sampling, operating all systems to allow system response time to elapse. Then all sampling and recording shall be stopped, including the recording of background samples. Finally, any integrating devices shall be stopped and the end of the test cycle shall be indicated in the recorded data;
(e) Post-test procedures according to paragraph 7.4. shall be performed.
Validation criteria
RMC tests shall be validated using the regression analysis as described in paragraphs 7.8.3.3. and 7.8.3.5. The allowed RMC tolerances are given in the following Table 7.1. Note that the RMC tolerances are different from the NRTC tolerances of Table 7.2.
.1
RMC Regression line tolerances
Speed Torque Power
max 2 % of max 2 % of
Standard error of estimate max 1 % of rated maximum engine maximum engine
(SEE) of y on x speed torque power
Slope of the regression line,
a1 0.99 to 1.01 0.98 to 1.02 0.98 to 1.02
Coefficient of
determination, r2 min 0.990 min 0.950 min 0.950
±20 Nm or 2 % of ±4 kW or 2 % of
y intercept of the regression maximum torque, maximum power,
line, a0 ±1 % of rated speed whichever is greater whichever is greater
Annex 4B
In case of running the RMC test not on a transient test bed, where the second
by second speed and torque values are not available, the following validation
criteria shall be used.
At each mode the requirements for the speed and torque tolerances are given in
paragraph 7.8.1.3. For the 20 s linear speed and linear torque transitions
between the RMC steady-state test modes (paragraph 7.4.1.2.) the following
tolerances for speed and load shall be applied for the ramp, the speed shall be
held linear within ±2 per cent of rated speed. The torque shall be held linear
within ±5 per cent of the maximum torque at rated speed.Transient test cycle (NRTC)
Reference speeds and torques commands shall be sequentially executed to perform the transient test cycle. Speed and torque commands shall be issued at a frequency of at least 5 Hz. Because the reference test cycle is specified at 1 Hz, the in between speed and torque commands shall be linearly interpolated from the reference torque values generated from cycle generation. Small denormalized speed values near warm idle speed may cause low-speed idle governors to activate and the engine torque to exceed the reference torque even though the operator demand is at a minimum. In such cases, it is recommended to control the dynamometer so it gives priority to follow the reference torque instead of the reference speed and let the engine govern the speed. Under cold-start conditions engines may use an enhanced-idle device to quickly warm up the engine and aftertreatment devices. Under these conditions, very low normalized speeds will generate reference speeds below this higher enhanced idle speed. In this case it is recommended controlling the dynamometer so it gives priority to follow the reference torque and let the engine govern the speed when the operator demand is at minimum. During an emission test, reference speeds and torques and the feedback speeds and torques shall be recorded with a minimum frequency of 1 Hz, but preferably of 5 Hz or even 10 Hz. This larger recording frequency is important as it helps to minimize the biasing effect of the time lag between the reference and the measured feedback speed and torque values. The reference and feedback speeds and torques maybe recorded at lower frequencies (as low as 1 Hz), if the average values over the time interval between recorded values are recorded. The average values shall be calculated based on feedback values updated at a frequency of at least 5 Hz. These recorded values shall be used to calculate cycle-validation statistics and total work.
Engine preconditioning
To meet stable conditions for the following Emission test, the sampling system and the engine shall be preconditioned either by driving a full pre-NRTC cycle or driving the engine and the measuring systems under similar conditions as in the test cycle itself. If the test before was also a NRTC hot test, no additional conditioning is needed. A natural or forced cool-down procedure may be applied. For forced cool- down, good engineering judgment shall be used to set up systems to send cooling air across the engine, to send cool oil through the engine lubrication
Annex 4B
system, to remove heat from the coolant through the engine cooling system, and to remove heat from an exhaust after-treatment system. In the case of a forced after-treatment cool down, cooling air shall not be applied until the after- treatment system has cooled below its catalytic activation temperature. Any cooling procedure that results in unrepresentative emissions is not permitted. Pre-test procedures according to paragraph 7.3.1. have to be performed, including analyser calibration.
Performing an NRTC transient cycle test
Testing shall be started as follows: The test sequence shall commence immediately after the engine has started from cooled down condition in case of the cold NRTC test or from hot soak condition in case of the hot NRTC test. The instructions (Annex 5) shall be followed. Data logging, sampling of exhaust gases and integrating measured values shall be initiated simultaneously at the start of the engine. The test cycle shall be initiated when the engine starts and shall be executed according to the schedule of Annex 5. At the end of the cycle, sampling shall be continued, operating all systems to allow system response time to elapse. Then all sampling and recording shall be stopped, including the recording of background samples. Finally, any integrating devices shall be stopped and the end of the test cycle shall be indicated in the recorded data. Post-test procedures according to paragraph 7.3.2. have to be performed.
Cycle validation criteria for transient test cycle
In order to check the validity of a test, the cycle-validation criteria in this paragraph shall be applied to the reference and feedback values of speed, torque, power and overall work.
Calculation of cycle work
Before calculating the cycle work, any speed and torque values recorded during engine starting shall be omitted. Points with negative torque values have to be accounted for as zero work. The actual cycle work Wact (kWh) shall be calculated based on engine feedback speed and torque values. The reference cycle work Wref (kWh) shall be calculated based on engine reference speed and torque values. The actual cycle work Wact is used for comparison to the reference cycle work Wref and for calculating the brake specific emissions (see paragraph 7.2.) Wact shall be between 85 per cent and 105 per cent of Wref.
Validation statistics (see Annex 4B Appendix A.2.)
Linear regression between the reference and the feedback values shall be calculated for speed, torque and power. To minimize the biasing effect of the time lag between the reference and feedback cycle values, the entire engine speed and torque feedback signal sequence may be advanced or delayed in time with respect to the reference speed and torque sequence. If the feedback signals are shifted, both speed and torque shall be shifted by the same amount in the same direction.
Annex 4B
The method of least squares shall be used, with the best-fit equation having the form: y = a1x + a0 (7-6) where: y = feedback value of speed (min-1), torque (Nm), or power (kW) a1 = slope of the regression line x = reference value of speed (min-1), torque (Nm), or power (kW) a0 = y intercept of the regression line The standard error of estimate (SEE) of y on x and the coefficient of determination (r²) shall be calculated for each regression line (Annex 4B Appendix A.2.). It is recommended that this analysis be performed at 1 Hz. For a test to be considered valid, the criteria of Table 7.2 of this paragraph shall be met.
Regression line tolerances
Speed Torque Power
Standard error of estimate ≤ 5.0 per cent of ≤ 10.0 per cent of ≤ 10.0 per cent of (SEE) of y on x maximum test speed maximum mapped torque maximum mapped power
Slope of the regression line, 0.95 to 1.03 0.83 to 1.03 0.89 to 1.03 a1
Coefficient of minimum 0.970 minimum 0.850 minimum 0.910 determination, r²
y intercept of the regression ≤ 10 per cent of idle ±20 Nm or ±2 per cent of ±4 kW or ±2 per cent of line, a0 maximum torque maximum power whichever is greater whichever is greater
For regression purposes only, point deletions are permitted where noted in those points shall not be deleted for the calculation of cycle work and emissions. An idle point is defined as a point having a normalised reference torque of 0 per cent and a normalized reference speed of 0 per cent. Point deletion may be applied to the whole or to any part of the cycle; points to which the point deletion is applied have to be specified.
Annex 4B
Permitted point deletions from regression analysis
Event Conditions (n = engine speed, T = torque) Permitted point deletions
Minimum operator demand (idle nref = nidle speed and power point) and Tref = 0 and Tact > (Tref - 0.02 Tmaxmappedtorque) and Tact < (Tref + 0.02 Tmaxmappedtorque)
Minimum operator demand nact ≤ 1.02 nref and Tact > Tref power and either torque or or speed nact > nref and Tact ≤ Tref' or nact > 1.02 nref and Tref < Tact ≤ (Tref + 0.02 Tmaxmappedtorque)
Maximum operator demand nact < nref and Tact ≥ Tref power and either torque or or speed nact ≥ 0.98 nref and Tact < Tref or nact < 0.98 nref and Tref > Tact ≥ (Tref – 0.02 Tmaxmappedtorque)
8.Measurement procedures
Calibration and performance checks
Introduction
This paragraph describes required calibrations and verifications of measurement systems. See paragraph 9.4. for specifications that apply to individual instruments. Calibrations or verifications shall be generally performed over the complete measurement chain. If a calibration or verification for a portion of a measurement system is not specified, that portion of the system shall be calibrated and its performance verified at a frequency consistent with any recommendations from the measurement system manufacturer and consistent with good engineering judgment. Internationally recognized-traceable standards shall be used to meet the tolerances specified for calibrations and verifications.
Summary of calibration and verification
The Table 8.1 summarizes the calibrations and verifications described in paragraph 8. and indicates when these have to be performed.
Annex 4B
.1
Summary of Calibration and Verifications Type of calibration or a verification Minimum frequency 8.1.3.: Accuracy, Accuracy: Not required, but recommended for initial installation. repeatability and noise Repeatability: Not required, but recommended for initial installation. Noise: Not required, but recommended for initial installation. 8.1.4.: Linearity Speed: Upon initial installation, within 370 days before testing and after major maintenance. Torque: Upon initial installation, within 370 days before testing and after major maintenance. Clean gas and diluted exhaust flows: Upon initial installation, within 370 days before testing and after major maintenance, unless flow is verified by propane check or by carbon or oxygen balance. Raw exhaust flow: Upon initial installation, within 185 days before testing and after major maintenance, unless flow is verified by propane check or by carbon or oxygen balance. Gas analysers: Upon initial installation, within 35 days before testing and after major maintenance. PM balance: Upon initial installation, within 370 days before testing and after major maintenance. Stand-alone pressure and temperature: Upon initial installation, within 370 days before testing and after major maintenance. 8.1.5.: Continuous gas Upon initial installation or after system modification that would effect response. analyser system response and updating-recording verification – for gas analysers not continuously compensated for other gas species 8.1.6.: Continuous gas Upon initial installation or after system modification that would effect response. analyser system response and updating-recording verification – for gas analysers continuously compensated for other gas species 8.1.7.1.: Torque Upon initial installation and after major maintenance. 8.1.7.2.: Pressure, Upon initial installation and after major maintenance. temperature, dew point 8.1.8.1.: Fuel flow Upon initial installation and after major maintenance. Annex 4B Type of calibration or a verification Minimum frequency 8.1.8.2.: Intake flow Upon initial installation and after major maintenance. 8.1.8.3.: Exhaust flow Upon initial installation and after major maintenance. 8.1.8.4.: Diluted exhaust Upon initial installation and after major maintenance. flow (CVS and PFD) 8.1.8.5.: CVS/PFD and Upon initial installation, within 35 days before testing, and after major maintenance. batch sampler (Propane check) verificationb 8.1.8.8.: Vacuum leak Before each laboratory test according to paragraph 7.1. 8.1.9.1.: CO2 NDIR H2O Upon initial installation and after major maintenance. interference 8.1.9.2.: CO NDIR CO2 Upon initial installation and after major maintenance. and H2O interference 8.1.10.1.: FID calibration Calibrate, optimize, and determine CH4 response: upon initial installation and after major maintenance. THC FID optimization and THC FID Verify CH4 response: upon initial installation, within 185 days before testing, and after verification major maintenance. 8.1.10.2.: Raw exhaust For all FID analysers: upon initial installation, and after major maintenance. FID O2 interference For THC FID analysers: upon initial installation, after major maintenance, and after FID optimization according to 8.1.10.1. 8.1.10.3.: Non-methane Upon initial installation, within 185 days before testing, and after major maintenance. cutter penetration 8.1.11.1.: CLD CO2 and Upon initial installation and after major maintenance. H2O quench 8.1.11.3.: NDUV HC and Upon initial installation and after major maintenance. H2O interference 8.1.11.4.: Cooling bath Upon initial installation and after major maintenance. NO2 penetration (chiller) 8.1.11.5.: NO2-to-NO Upon initial installation, within 35 days before testing, and after major maintenance. converter conversion 8.1.12.1.: PM balance Independent verification: upon initial installation, within 370 days before testing, and and weighing after major maintenance. Zero, span, and reference sample verifications: within 12 hours of weighing, and after major maintenance. a Perform calibrations and verifications more frequently, according to measurement system manufacturer instructions and good engineering judgment. b The CVS verification is not required for systems that agree within ±2 per cent based on a chemical balance of carbon or oxygen of the intake air, fuel, and diluted exhaust. Annex 4B
Verifications for accuracy, repeatability, and noise
The performance values for individual instruments specified in Table 9.3 are the basis for the determination of the accuracy, repeatability, and noise of an instrument. It is not required to verify instrument accuracy, repeatability, or noise. However, it may be useful to consider these verifications to define a specification for a new instrument, to verify the performance of a new instrument upon delivery, or to troubleshoot an existing instrument.
Linearity check
Scope and frequency
A linearity verification shall be performed on each measurement system listed in Table 8.2 at least as frequently as indicated in the table, consistent with measurement system manufacturer recommendations and good engineering judgment. The intent of a linearity verification is to determine that a measurement system responds proportionally over the measurement range of interest. A linearity verification shall consist of introducing a series of at least 10 reference values to a measurement system, unless otherwise specified. The measurement system quantifies each reference value. The measured values shall be collectively compared to the reference values by using a least squares linear regression and the linearity criteria specified in Table 8.2 of this paragraph.
Performance requirements
If a measurement system does not meet the applicable linearity criteria in replacing components as needed. The linearity verification shall be repeated after correcting the deficiency to ensure that the measurement system meets the linearity criteria.
Procedure
The following linearity verification protocol shall be used:
(a) A measurement system shall be operated at its specified temperatures, pressures, and flows;
(b) The instrument shall be zeroed as it would before an emission test by introducing a zero signal. For gas analysers, a zero gas shall be used that meets the specifications of paragraph 9.5.1. and it shall be introduced directly at the analyser port;
(c) The instrument shall be spanned as it would before an emission test by introducing a span signal. For gas analysers, a span gas shall be used that meets the specifications of paragraph 9.5.1. and it shall be introduced directly at the analyser port;
(d) After spanning the instrument, zero shall be checked with the same signal which has been used in sub-paragraph (b) of this paragraph. Based on the zero reading, good engineering judgment shall be used to determine whether or not to re-zero and or re-span the instrument before proceeding to the next step;
(e) For all measured quantities manufacturer recommendations and good engineering judgment shall be used to select the reference values, yrefi, that cover the full range of values that are expected during emission testing,
Annex 4B
thus avoiding the need of extrapolation beyond these values. A zero reference signal shall be selected as one of the reference values of the linearity verification. For stand-alone pressure and temperature linearity verifications, at least three reference values shall be selected. For all other linearity verifications, at least ten reference values shall be selected;
(f) Instrument manufacturer recommendations and good engineering judgment shall be used to select the order in which the series of reference values will be introduced;
(g) Reference quantities shall be generated and introduced as described in paragraph 8.1.4.4. For gas analysers, gas concentrations known to be within the specifications of paragraph 9.5.1. shall be used and they shall be introduced directly at the analyser port;
(h) Time for the instrument to stabilize while it measures the reference value shall be allowed;
(i) At a recording frequency of at least the minimum frequency, as specified in Table 9.2, the reference value shall be measured for 30 s and the arithmetic mean of the recorded values, yi recorded;
(j) Steps in sub-paragraphs (g) through (i) of this paragraph shall be repeated until all reference quantities are measured;
(k) The arithmetic means yi , and reference values, yrefi, shall be used to calculate least-squares linear regression parameters and statistical values to compare to the minimum performance criteria specified in Table 8.2. The calculations described in Annex 4B Appendix A.2 paragraph A.2. shall be used.
Reference signals
This paragraph describes recommended methods for generating reference values for the linearity-verification protocol in paragraph 8.1.4.3. of this section. Reference values shall be used that simulate actual values, or an actual value shall be introduced and measured with a reference-measurement system. In the latter case, the reference value is the value reported by the reference- measurement system. Reference values and reference-measurement systems shall be internationally traceable. For temperature measurement systems with sensors like thermocouples, RTDs, and thermistors, the linearity verification may be performed by removing the sensor from the system and using a simulator in its place. A simulator that is independently calibrated and cold junction compensated, as necessary shall be used. The internationally traceable simulator uncertainty scaled to temperature shall be less than 0.5 per cent of maximum operating temperature Tmax. If this option is used, it is necessary to use sensors that the supplier states are accurate to better than 0.5 per cent of Tmax compared to their standard calibration curve.
Measurement systems that require linearity verification
For this table the following provisions apply.
(a) A linearity verification shall be performed more frequently if the instrument manufacturer recommends it or based on good engineering judgment;
Annex 4B
(b) "min" refers to the minimum reference value used during the linearity verification; Note that this value may be zero or a negative value depending on the signal;
(c) "max" generally refers to the maximum reference value used during the linearity verification. For example for gas dividers, xmax is the undivided, undiluted, span gas concentration. The following are special cases where "max" refers to a different value:
(i) For PM balance linearity verification, mmax refers to the typical mass of a PM filter;
(ii) For torque linearity verification, Tmax refers to the manufacturer's specified engine torque peak value of the highest torque engine to be tested.
(d) The specified ranges are inclusive. For example, a specified range of 0.98-1.02 for the slope a1 means 0.98 ≤ a1 ≤ 1.02;
(e) These linearity verifications are not required for systems that pass the flow-rate verification for diluted exhaust as described 8.1.8.5. for the propane check or for systems that agree within ±2 per cent based on a chemical balance of carbon or oxygen of the intake air, fuel, and exhaust;
(f) a1 criteria for these quantities shall be met only if the absolute value of the quantity is required, as opposed to a signal that is only linearly proportional to the actual value;
(g) Stand-alone temperatures include engine temperatures and ambient conditions used to set or verify engine conditions; temperatures used to set or verify critical conditions in the test system; and temperatures used in emissions calculations:
(i) These temperature linearity checks are required. Air intake; aftertreatment bed(s) (for engines tested with aftertreatment devices on cycles with cold start criteria); dilution air for PM sampling (CVS, double dilution, and partial flow systems); PM sample; and chiller sample (for gaseous sampling systems that use chillers to dry samples);
(ii) These temperature linearity checks are only required if specified by the engine manufacturer. Fuel inlet; test cell charge air cooler air outlet (for engines tested with a test cell heat exchanger simulating a vehicle/machine charge air cooler); test cell charge air cooler coolant inlet (for engines tested with a test cell heat exchanger simulating a vehicle/machine charge air cooler); and oil in the sump/pan; coolant before the thermostat (for liquid cooled engines);
(h) Stand-alone pressures include engine pressures and ambient conditions used to set or verify engine conditions; pressures used to set or verify critical conditions in the test system; and pressures used in emissions calculations:
(i) Required pressure linearity checks are: air intake restriction; exhaust back pressure; barometer; CVS inlet gage pressure (if measurement using CVS); chiller sample (for gaseous sampling systems that use chillers to dry samples);
Annex 4B
(ii) Pressure linearity checks that are required only if specified by the engine manufacturer: test cell charge air cooler and interconnecting pipe pressure drop (for turbo-charged engines tested with a test cell heat exchanger simulating a vehicle/machine charge air cooler) fuel inlet; and fuel outlet.
Measurement systems that require linearity verifications
Linearity Criteria
Measurement Minimum verification xmin ⋅ (a1 − 1) + a0 System Quantity frequency a SEE r2 Engine speed n Within 370 days ≤ 0.05 % nmax 0.98-1.02 ≤ 2 % nmax ≥ 0.990 before testing
Engine torque T Within 370 days ≤ 1 % Tmax 0.98-1.02 ≤ 2 % Tmax ≥ 0.990 before testing
Fuel flow rate qm Within 370 days ≤ 1 % qm , max 0.98-1.02 ≤ 2 % qm , max ≥ 0.990 before testing
Intake-air flow qV Within 370 days ≤ 1 % qV , max 0.98-1.02 ≤ 2 % qV , max ≥ 0.990 rate before testing
Dilution air qV Within 370 days ≤ 1 % qV , max 0.98-1.02 ≤ 2 % qV , max ≥ 0.990 flow rate before testing
Diluted exhaust qV Within 370 days ≤ 1 % qV , max 0.98-1.02 ≤ 2 % qV , max ≥ 0.990 flow rate before testing
Raw exhaust qV Within 185 days ≤ 1 % qV , max 0.98-1.02 ≤ 2 % qV , max ≥ 0.990 flow rate before testing
Batch sampler qV Within 370 days ≤ 1 % qV , max 0.98-1.02 ≤ 2 % qV , max ≥ 0.990 flow rates before testing
Gas dividers x xspan Within 370 days ≤ 0.5 % xmax 0.98-1.02 ≤ 2 % xmax ≥ 0.990 before testing
Gas analysers x Within 35 days ≤ 0.5 % xmax 0.99-1.01 ≤ 1 % xmax ≥ 0.998 before testing
PM balance m Within 370 days ≤ 1 % mmax 0.99-1.01 ≤ 1 % mmax ≥ 0.998 before testing
Stand-alone p Within 370 days ≤ 1 % pmax 0.99-1.01 ≤ 1 % pmax ≥ 0.998 pressures before testing
Analog-to-digital T Within 370 days ≤ 1 % Tmax 0.99-1.01 ≤ 1 % Tmax ≥ 0.998 conversion of before testing stand-alone temperature signals
Annex 4B
Continuous gas analyser system-response and updating-recording verification
This section describes a general verification procedure for continuous gas analyser system response and update recording. See paragraph 8.1.6. for verification procedures for compensation type analysers.
Scope and frequency
This verification shall be performed after installing or replacing a gas analyser that is used for continuous sampling. Also this verification shall be performed if the system is reconfigured in a way that would change system response. This verification is needed for continuous gas analysers used for transient or ramped-modal testing but is not needed for batch gas analyser systems or for continuous gas analyser systems used only for discrete-mode testing.
Measurement principles
This test verifies that the updating and recording frequencies match the overall system response to a rapid change in the value of concentrations at the sample probe. Gas analyser systems shall be optimized such that their overall response to a rapid change in concentration is updated and recorded at an appropriate frequency to prevent loss of information. This test also verifies that continuous gas analyser systems meet a minimum response time. The system settings for the response time evaluation shall be exactly the same as during measurement of the test run (i.e. pressure, flow rates, filter settings on the analysers and all other response time influences). The response time determination shall be done with gas switching directly at the inlet of the sample probe. The devices for gas switching shall have a specification to perform the switching in less than 0.1 s. The gases used for the test shall cause a concentration change of at least 60 per cent full scale (FS). The concentration trace of each single gas component shall be recorded.
System requirements
(a) The system response time shall be ≤ 10 s with a rise time of ≤ 2.5 s or with a rise and fall time of ≤ 5 s each for all measured components (CO, NOx, CO2 and HC) and all ranges used. When using a NMC for the measurement of NMHC, the system response time may exceed 10 s. All data (concentration, fuel and air flows) have to be shifted by their measured response times before performing the emission calculations given in Annexes A.7-A.8.
(b) To demonstrate acceptable updating and recording with respect to the system's overall response, the system shall meet one of the following criteria:
(i) The product of the mean rise time and the frequency at which the system records an updated concentration shall be at least 5. In any case the mean rise time shall be no more than 10 s;
(ii) The frequency at which the system records the concentration shall be at least 2 Hz (see also Table 9.2).
Annex 4B
Procedure
The following procedure shall be used to verify the response of each continuous gas analyser system:
(a) The analyser system manufacturer's start-up and operating instructions for the instrument setup shall be followed. The measurement system shall be adjusted as needed to optimize performance. This verification shall be run with the analyser operating in the same manner as used for emission testing. If the analyser shares its sampling system with other analysers, and if gas flow to the other analysers will affect the system response time, then the other analysers shall be started up and operated while running this verification test. This verification test may be run on multiple analysers sharing the same sampling system at the same time. If analogue or real-time digital filters are used during emission testing, those filters shall be operated in the same manner during this verification;
(b) For equipment used to validate system response time, minimal gas transfer line lengths between all connections are recommended to be used, a zero-air source shall be connected to one inlet of a fast-acting 3-way valve (2 inlets, 1 outlet) in order to control the flow of zero and blended span gases to the sample system's probe inlet or a tee near the outlet of the probe. Normally the gas flow rate is higher than the probe sample flow rate and the excess is overflowed out the inlet of the probe. If the gas flow rate is lower than the probe flow rate, the gas concentrations shall be adjusted to account for the dilution from ambient air drawn into the probe. Binary or multi-gas span gases may be used. A gas blending or mixing device may be used to blend span gases. A gas blending or mixing device is recommended when blending span gases diluted in N2 with span gases diluted in air; Using a gas divider, an NO–CO–CO2–C3H8–CH4 (balance N2) span gas shall be equally blended with a span gas of NO2, balance purified synthetic air. Standard binary span gases may be also be used, where applicable, in place of blended NO-CO-CO2-C3H8-CH4, balance N2 span gas; in this case separate response tests shall be run for each analyser. The gas divider outlet shall be connected to the other inlet of the 3-way valve. The valve outlet shall be connected to an overflow at the gas analyser system's probe or to an overflow fitting between the probe and transfer line to all the analysers being verified. A setup that avoids pressure pulsations due to stopping the flow through the gas blending device shall be used. Any of these gas constituents if they are not relevant to the analysers for this verification shall be omitted. Alternatively the use of gas bottles with single gases and a separate measurement of response times is allowed;
(c) Data collection shall be done as follows:
(i) The valve shall be switched to start the flow of zero gas;
(ii) Stabilization shall be allowed for, accounting for transport delays and the slowest analyser's full response;
Annex 4B
(iii) Data recording shall be started at the frequency used during emission testing. Each recorded value shall be a unique updated concentration measured by the analyser; interpolation or filtering may not be used to alter recorded values;
(iv) The valve shall be switched to allow the blended span gases to flow to the analysers. This time shall be recorded as t0;
(v) Transport delays and the slowest analyser's full response shall be allowed for;
(vi) The flow shall be switched to allow zero gas to flow to the analyser. This time shall be recorded as t100;
(vii) Transport delays and the slowest analyser's full response shall be allowed for;
(viii) The steps in sub-paragraphs (c) (iv) through (vii) of this paragraph shall be repeated to record seven full cycles, ending with zero gas flowing to the analysers;
(ix) Recording shall be stopped.
Performance evaluation
The data from sub-paragraph (c) of paragraph 8.1.5.4. of this section shall be used to calculate the mean rise time, T10–90 for each of the analysers.
(a) If it is chosen to demonstrate compliance with sub-paragraphs (b) (i) of paragraph 8.1.5.3. of this section, the following procedure has to be applied: The rise times (in s) shall be multiplied by their respective recording frequencies in Hertz (1/s). The value for each result shall be at least 5. If the value is less than 5, the recording frequency shall be increased or the flows adjusted or the design of the sampling system shall be changed to increase the rise time as needed. Also digital filters may be configured to increase rise time;
(b) If it is choosen to demonstrate compliance with sub-paragraphs (b) (ii) of paragraph 8.1.5.3. of this section, the demonstration of compliance with the requirements of sub-paragraphs (b) (ii) of paragraph 8.1.5.3. is sufficient.
Response time verification for compensation type analysers
Scope and frequency
This verification shall be performed to determine a continuous gas analyser's response, where one analyser's response is compensated by another's to quantify a gaseous emission. For this check water vapour shall be considered to be a gaseous constituent. This verification is required for continuous gas analysers used for transient or ramped-modal testing. This verification is not needed for batch gas analysers or for continuous gas analysers that are used only for discrete- mode testing. This verification does not apply to correction for water removed from the sample done in post-processing and it does not apply to NMHC determination from THC and CH4 quoted in Annexes A.7 and A.8 concerning the emission calculations. This verification shall be performed after initial installation (i.e. test cell commissioning). After major maintenance, paragraph 8.1.5. may be used to verify uniform response provided that any replaced components have gone through a humidified uniform response verification at some point.
Annex 4B
Measurement principles
This procedure verifies the time-alignment and uniform response of continuously combined gas measurements. For this procedure, it is necessary to ensure that all compensation algorithms and humidity corrections are turned on.
System requirements
The general response time and rise time requirement given in sub-paragraph (a) of 8.1.5.3. is also valid for compensation type analysers. Additionally, if the recording frequency is different than the update frequency of the continuously combined/compensated signal, the lower of these two frequencies shall be used for the verification required by sub-paragraphs (b) (i) of paragraph 8.1.5.3.
Procedure
All procedures given in sub-paragraphs (a) - (c) of paragraph 8.1.5.4. have to be used. Additionally also the response and rise time of water vapour has to be measured, if a compensation algorithm based on measured water vapour is used. In this case at least one of the used calibration gases (but not NO2) has to be humidified as follows: If the system does not use a sample dryer to remove water from the sample gas, the span gas shall be humidified by flowing the gas mixture through a sealed vessel that humidifies the gas to the highest sample dew point that is estimated during emission sampling by bubbling it through distilled water. If the system uses a sample dryer during testing that has passed the sample dryer verification check, the humidified gas mixture may be introduced downstream of the sample dryer by bubbling it through distilled water in a sealed vessel at (25 ± 10 °C), or a temperature greater than the dew point. In all cases, downstream of the vessel, the humidified gas shall be maintained at a temperature of at least 5 ºC above its local dew point in the line. Note that it is possible to omit any of these gas constituents if they are not relevant to the analysers for this verification. If any of the gas constituents are not susceptible to water compensation, the response check for these analysers may be performed without humidification.
Measurement of engine parameters and ambient conditions
The engine manufacturer shall apply internal quality procedures traceable to recognised national or international standards. Otherwise the following procedures apply.
Torque calibration
Scope and frequency
All torque-measurement systems including dynamometer torque measurement transducers and systems shall be calibrated upon initial installation and after major maintenance using, among others, reference force or lever-arm length coupled with dead weight. Good engineering judgment shall be used to repeat the calibration. The torque transducer manufacturer's instructions shall be followed for linearizing the torque sensor's output. Other calibration methods are permitted.
Annex 4B
Dead-weight calibration
This technique applies a known force by hanging known weights at a known distance along a lever arm. It shall be made sure that the weights' lever arm is perpendicular to gravity (i.e., horizontal) and perpendicular to the dynamometer's rotational axis. At least six calibration-weight combinations shall be applied for each applicable torque-measuring range, spacing the weight quantities about equally over the range. The dynamometer shall be oscillated or rotated during calibration to reduce frictional static hysteresis. Each weight's force shall be determined by multiplying its internationally-traceable mass by the local acceleration of Earth's gravity.
Strain gage or proving ring calibration
This technique applies force either by hanging weights on a lever arm (these weights and their lever arm length are not used as part of the reference torque determination) or by operating the dynamometer at different torques. At least six force combinations shall be applied for each applicable torque-measuring range, spacing the force quantities about equally over the range. The dynamometer shall be oscillated or rotated during calibration to reduce frictional static hysteresis. In this case, the reference torque is determined by multiplying the force output from the reference meter (such as a strain gage or proving ring) by its effective lever-arm length, which is measured from the point where the force measurement is made to the dynamometer's rotational axis. It shall be made sure that this length is measured perpendicular to the reference meter's measurement axis and perpendicular to the dynamometer's rotational axis.
Pressure, temperature, and dew point calibration
Instruments shall be calibrated for measuring pressure, temperature, and dew point upon initial installation. The instrument manufacturer's instructions shall be followed and good engineering judgment shall be used to repeat the calibration. For temperature measurement systems with thermocouple, RTD, or thermistor sensors, the calibration of the system shall be performed as described in paragraph 8.1.4.4. for linearity verification.
Flow-related measurements
Fuel flow calibration
Fuel flow-meters shall be calibrated upon initial installation. The instrument manufacturer's instructions shall be followed and good engineering judgment shall be used to repeat the calibration.
Intake air flow calibration
Intake air flow-meters shall be calibrated upon initial installation. The instrument manufacturer's instructions shall be followed and good engineering judgment shall be used to repeat the calibration.
Exhaust flow calibration
Exhaust flow-meters shall be calibrated upon initial installation. The instrument manufacturer's instructions shall be followed and good engineering judgment shall be used to repeat the calibration.
Annex 4B
Diluted exhaust flow (CVS) calibration
Overview
(a) This section describes how to calibrate flow-meters for diluted exhaust constant-volume sampling (CVS) systems;
(b) This calibration shall be performed while the flow-meter is installed in its permanent position. This calibration shall be performed after any part of the flow configuration upstream or downstream of the flow-meter has been changed that may affect the flow-meter calibration. This calibration shall be performed upon initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted exhaust flow verification (i.e., propane check) in paragraph 8.1.8.5.;
(c) A CVS flow-meter shall be calibrated using a reference flow-meter such as a subsonic venturi flow-meter, a long-radius flow nozzle, a smooth approach orifice, a laminar flow element, a set of critical flow venturis, or an ultrasonic flow-meter. A reference flow-meter shall be used that reports quantities that are internationally-traceable within ±1 per cent uncertainty. This reference flow-meter's response to flow shall be used as the reference value for CVS flow-meter calibration;
(d) An upstream screen or other restriction that could affect the flow ahead of the reference flow-meter may not be used, unless the flow-meter has been calibrated with such a restriction;
(e) The calibration sequence described under this paragraph 8.1.8.4. refers to the molar based approach. For the corresponding sequence used in the mass based approach, see Annex 8 Appendix 1.
PDP calibration
A positive-displacement pump (PDP) shall be calibrated to determine a flow- versus-PDP speed equation that accounts for flow leakage across sealing surfaces in the PDP as a function of PDP inlet pressure. Unique equation coefficients shall be determined for each speed at which the PDP is operated. A PDP flow-meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 8.1;
(b) Leaks between the calibration flow-meter and the PDP shall be less than 0.3 per cent of the total flow at the lowest calibrated flow point; for example, at the highest restriction and lowest PDP-speed point;
(c) While the PDP operates, a constant temperature at the PDP inlet shall be maintained within ±2 per cent of the mean absolute inlet temperature, Tin;
(d) The PDP speed is set to the first speed point at which it is intended to calibrate;
(e) The variable restrictor is set to its wide-open position;
(f) The PDP is operated for at least 3 min to stabilize the system. Then by continuously operating the PDP, the mean values of at least 30 s of sampled data of each of the following quantities are recorded:
(i) The mean flow rate of the reference flow-meter, qVref ;
Annex 4B
(ii) The mean temperature at the PDP inlet, Tin;
(iii) The mean static absolute pressure at the PDP inlet, pin;
(iv) The mean static absolute pressure at the PDP outlet, pout;
(v) The mean PDP speed, nPDP;
(g) The restrictor valve shall be incrementally closed to decrease the absolute pressure at the inlet to the PDP, pin;
(h) The steps in sub-paragraphs (f) and (g) of paragraph 8.1.8.4.2. shall be repeated to record data at a minimum of six restrictor positions reflecting the full range of possible in-use pressures at the PDP inlet;
(i) The PDP shall be calibrated by using the collected data and the equations in Annexes A.7-A.8;
(j) The steps in sub-paragraphs (f) through (i) of this section shall be repeated for each speed at which the PDP is operated;
(k) The equations in Annex 4B Appendix A.7 (molar based approach) or A.8 (mass based approach) shall be used to determine the PDP flow equation for emission testing;
(l) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in paragraph 8.1.8.5.;
(m) The PDP may not be used below the lowest inlet pressure tested during calibration.
CFV calibration
A critical-flow venturi (CFV) shall be calibrated to verify its discharge coefficient, Cd, at the lowest expected static differential pressure between the CFV inlet and outlet. A CFV flow-meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 8.1;
(b) The blower shall be started downstream of the CFV;
(c) While the CFV operates, a constant temperature at the CFV inlet shall be maintained within ±2 per cent of the mean absolute inlet temperature, Tin;
(d) Leaks between the calibration flow-meter and the CFV shall be less than 0.3 per cent of the total flow at the highest restriction;
(e) The variable restrictor shall be set to its wide-open position. In lieu of a variable restrictor the pressure downstream of the CFV may be varied by varying blower speed or by introducing a controlled leak. Note that some blowers have limitations on non-loaded conditions;
(f) The CFV shall be operated for at least 3 min to stabilize the system. The CFV shall continue operating and the mean values of at least 30 s of sampled data of each of the following quantities shall be recorded:
(i) The mean flow rate of the reference flow-meter, qVref ;
Annex 4B
(ii) Optionally, the mean dew point of the calibration air, Tdew. See Annexes A.7-A.8 for permissible assumptions during emission measurements;
(iii) The mean temperature at the venturi inlet, Tin;
(iv) The mean static absolute pressure at the venturi inlet, pin;
(v) The mean static differential pressure between the CFV inlet and the CFV outlet, ΔpCFV;
(g) The restrictor valve shall be incrementally closed to decrease the absolute pressure at the inlet to the CFV, pin;
(h) The steps in sub-paragraphs (f) and (g) of this paragraph shall be repeated to record mean data at a minimum of ten restrictor positions, such that the fullest practical range of ΔpCFV expected during testing is tested. It is not required to remove calibration components or CVS components to calibrate at the lowest possible restrictions;
(i) Cd and the lowest allowable pressure ratio r shall be determined as described in Annexes A.7-A.8;
(j) Cd shall be used to determine CFV flow during an emission test. The CFV shall not be used below the lowest allowed r, as determined in Annexes A.7-A.8;
(k) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in paragraph 8.1.8.5.;
(l) If the CVS is configured to operate more than one CFV at a time in parallel, the CVS shall be calibrated by one of the following:
(i) Every combination of CFVs shall be calibrated according to this paragraph and Annexes A.7-A.8. See Annexes A.7-A.8 for instructions on calculating flow rates for this option;
(ii) Each CFV shall be calibrated according to this paragraph and Annexes A.7-A.8. See Annexes A.7-A.8 for instructions on calculating flow rates for this option.
SSV calibration
A subsonic venturi (SSV) shall be calibrated to determine its calibration coefficient, Cd , for the expected range of inlet pressures. An SSV flow-meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 8.1;
(b) The blower shall be started downstream of the SSV;
(c) Leaks between the calibration flow-meter and the SSV shall be less than 0.3 per cent of the total flow at the highest restriction;
(d) While the SSV operates, a constant temperature at the SSV inlet shall be maintained within ±2 per cent of the mean absolute inlet temperature, Tin;
Annex 4B
(e) The variable restrictor or variable-speed blower shall be set to a flow rate greater than the greatest flow rate expected during testing. Flow rates may not be extrapolated beyond calibrated values, so it is recommended that it is made certain that a Reynolds number, Re, at the SSV throat at the greatest calibrated flow rate is greater than the maximum Re expected during testing;
(f) The SSV shall be operated for at least 3 min to stabilize the system. The SSV shall continue operating and the mean of at least 30 s of sampled data of each of the following quantities shall be recorded:
(i) The mean flow rate of the reference flow-meter, qVref ;
(ii) Optionally, the mean dew point of the calibration air, Tdew. See Annexes A.7-A.8 for permissible assumptions;
(iii) The mean temperature at the venturi inlet, Tin;
(iv) The mean static absolute pressure at the venturi inlet, pin;
(v) Static differential pressure between the static pressure at the venturi inlet and the static pressure at the venturi throat, ΔpSSV;
(g) The restrictor valve shall be incrementally closed or the blower speed decreased to decrease the flow rate;
(h) The steps in sub-paragraphs (f) and (g) of this paragraph shall be repeated to record data at a minimum of ten flow rates;
(i) A functional form of Cd versus Re shall be determined by using the collected data and the equations in Annexes A.7-A.8;
(j) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in paragraph 8.1.8.5. using the new Cd versus Re equation;
(k) The SSV shall be used only between the minimum and maximum calibrated flow rates;
(l) The equations in Annex 4B Appendix A.7 (molar based approach) or Annex 4B Appendix A.8 (mass based approach) shall be used to determine SSV flow during a test.
Annex 4B
Ultrasonic calibration (reserved)
Schematic diagrams for diluted exhaust flow CVS calibration
Annex 4B
CVS and batch sampler verification (propane check)
Introduction
(a) A propane check serves as a CVS verification to determine if there is a discrepancy in measured values of diluted exhaust flow. A propane check also serves as a batch-sampler verification to determine if there is a discrepancy in a batch sampling system that extracts a sample from a CVS, as described in sub-paragraph (f) of this paragraph. Using good engineering judgment and safe practices, this check may be performed using a gas other than propane, such as CO2 or CO. A failed propane check might indicate one or more problems that may require corrective action, as follows:
(i) Incorrect analyser calibration. The FID analyser shall be re- calibrated, repaired, or replaced;
(ii) Leak checks shall be performed on CVS tunnel, connections, fasteners, and HC sampling system according to paragraph 8.1.8.7.;
(iii) The verification for poor mixing shall be performed in accordance with paragraph 9.2.2.;
(iv) The hydrocarbon contamination verification in the sample system shall be performed as described in paragraph 7.3.1.2.;
(v) Change in CVS calibration. An in-situ calibration of the CVS flow-meter shall be performed as described in paragraph 8.1.8.4.;
(vi) Other problems with the CVS or sampling verification hardware or software. The CVS system, CVS verification hardware, and software shall be inspected for discrepancies;
(b) A propane check uses either a reference mass or a reference flow rate of C3H8 as a tracer gas in a CVS. If a reference flow rate is used, any non- ideal gas behaviour of C3H8 in the reference flow-meter shall be accounted for. See Annexes A.7 (molar based approach) or A.8 (mass based approach), which describe how to calibrate and use certain flow- meters. No ideal gas assumption may be used in paragraph 8.1.8.5. and Annexes A.7 or A.8. The propane check compares the calculated mass of injected C3H8 using HC measurements and CVS flow rate measurements with the reference value.
Method of introducing a known amount of propane into the CVS system
The total accuracy of the CVS sampling system and analytical system shall be determined by introducing a known mass of a pollutant gas into the system while it is being operated in the normal manner. The pollutant is analysed, and the mass calculated according to Annexes A.7-A.8. Either of the following two techniques shall be used.
(a) Metering by means of a gravimetric technique shall be done as follows: A mass of a small cylinder filled with carbon monoxide or propane shall be determined with a precision of ±0.01 g. For about 5 to 10 minutes, the CVS system shall be operated as in a normal exhaust emission test, while carbon monoxide or propane is injected into the system. The quantity of pure gas discharged shall be determined by means of
Annex 4B
differential weighing. A gas sample shall be analysed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated;
(b) Metering with a critical flow orifice shall be done as follows: A known quantity of pure gas (carbon monoxide or propane) shall be fed into the CVS system through a calibrated critical orifice. If the inlet pressure is high enough, the flow rate, which is adjusted by means of the critical flow orifice, is independent of the orifice outlet pressure (critical flow). The CVS system shall be operated as in a normal exhaust emission test for about 5 to 10 minutes. A gas sample shall be analysed with the usual equipment (sampling bag or integrating method), and the mass of the gas calculated.
Preparation of the propane check
The propane check shall be prepared as follows:
(a) If a reference mass of C3H8 is used instead of a reference flow rate, a cylinder charged with C3H8 shall be obtained. The reference cylinder's mass of C3H8 shall be determined within ±0.5 per cent of the amount of C3H8 that is expected to be used;
(b) Appropriate flow rates shall be selected for the CVS and C3H8;
(c) A C3H8 injection port shall be selected in the CVS. The port location shall be selected to be as close as practical to the location where engine exhaust is introduced into the CVS. The C3H8 cylinder shall be connected to the injection system;
(d) The CVS shall be operated and stabilized;
(e) Any heat exchangers in the sampling system shall be pre-heated or pre- cooled;
(f) Heated and cooled components such as sample lines, filters, chillers, and pumps shall be allowed to stabilize at operating temperature;
(g) If applicable, a vacuum side leak verification of the HC sampling system shall be performed as described in 8.1.8.7.
Preparation of the HC sampling system for the propane check
Vacuum side leak check verification of the HC sampling system may be performed according to sub-paragraph (g) of this paragraph. If this procedure is used, the HC contamination procedure in paragraph 7.3.1.2. may be used. If the vacuum side leak check is not performed according to sub-paragraph (g), then the HC sampling system shall be zeroed, spanned, and verified for contamination, as follows:
(a) The lowest HC analyser range that can measure the C3H8 concentration expected for the CVS and C3H8 flow rates shall be selected;
(b) The HC analyser shall be zeroed using zero air introduced at the analyser port;
(c) The HC analyser shall be spanned using C3H8 span gas introduced at the analyser port;
Annex 4B
(d) Zero air shall be overflowed at the HC probe or into a fitting between the HC probe and the transfer line;
(e) The stable HC concentration of the HC sampling system shall be measured as overflow zero air flows. For batch HC measurement, the batch container (such as a bag) shall be filled and the HC overflow concentration measured;
(f) If the overflow HC concentration exceeds 2 µmol/mol, the procedure may not be advanced until contamination is eliminated. The source of the contamination shall be determined and corrective action taken, such as cleaning the system or replacing contaminated portions;
(g) When the overflow HC concentration does not exceed 2 µmol/mol, this value shall be recorded as xHCinit and it shall be used to correct for HC contamination as described in Annex 4B Appendix A.7 (molar based approach) or Annex 4B Appendix A.8 (mass based approach).
Propane check performance
(a) The propane check shall be performed as follows:
(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;
(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;
(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;
(iv) Any integrating devices shall be zeroed;
(v) Sampling shall begin and any flow integrators shall be started;
(vi) C3H8 shall be released at the rate selected. If a reference flow rate of C3H8 is used, the integration of this flow rate shall be started;
(vii) C3H8 shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;
(viii) The C3H8 cylinder shall be shut off and sampling shall continue until it has been accounted for time delays due to sample transport and analyser response;
(ix) Sampling shall be stopped and any integrators shall be stopped;
(b) In case the metering with a critical flow orifice is used, the following procedure may be used for the propane check as the alternative method of sub-paragraph (a) paragraph 8.1.8.5.5.;
(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;
(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;
Annex 4B
(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;
(iv) Any integrating devices shall be zeroed;
(v) The contents of the C3H8 reference cylinder shall be released at the rate selected;
(vi) Sampling shall begin, and any flow integrators started after confirming that HC concentration is to be stable;
(vii) The cylinder's contents shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;
(viii) Any integrators shall be stopped;
(ix) The C3H8 reference cylinder shall be shut off.
Evaluation of the propane check
Post-test procedure shall be performed as follows:
(a) If batch sampling has been used, batch samples shall be analysed as soon as practical;
(b) After analysing HC, contamination and background shall be corrected for;
(c) Total C3H8 mass based on the CVS and HC data shall be calculated as described in Annexes A.7-A.8, using the molar mass of C3H8, MC3H8, instead the effective molar mass of HC, MHC;
(d) If a reference mass (gravimetric technique) is used, the cylinder's propane mass shall be determined within ±0.5 per cent and the C3H8 reference mass shall be determined by subtracting the empty cylinder propane mass from the full cylinder propane mass. If a critical flow orifice (metering with a critical flow orifice) is used, the propane mass shall be determined as flow rate multiplied by the test time;
(e) The reference C3H8 mass shall be subtracted from the calculated mass. If this difference is within ±3.0 per cent of the reference mass, the CVS passes this verification.
PM secondary dilution system verification
When the propane check is to be repeated to verify the PM secondary dilution system, the following procedure from sub-paragraphs (a) to (d) shall be used for this verification:
(a) The HC sampling system shall be configured to extract a sample near the location of the batch sampler's storage media (such as a PM filter). If the absolute pressure at this location is too low to extract an HC sample, HC may be sampled from the batch sampler pump's exhaust. Caution shall be used when sampling from pump exhaust because an otherwise acceptable pump leak downstream of a batch sampler flow-meter will cause a false failure of the propane check;
(b) The propane check shall be repeated as described in this paragraph, but HC shall be sampled from the batch sampler;
Annex 4B
(c) C3H8 mass shall be calculated, taking into account any secondary dilution from the batch sampler;
(d) The reference C3H8 mass shall be subtracted from the calculated mass. If this difference is within ±5 per cent of the reference mass, the batch sampler passes this verification. If not, corrective action shall be taken.
Sample dryer verification
If a humidity sensor for continuous monitoring of dew point at the sample dryer outlet is used this check does not apply, as long as it is ensured that the dryer outlet humidity is below the minimum values used for quench, interference, and compensation checks.
(a) If a sample dryer is used as allowed in paragraph 9.3.2.3.1. to remove water from the sample gas, the performance shall be verified upon installation, after major maintenance, for thermal chiller. For osmotic membrane dryers, the performance shall be verified upon installation, after major maintenance, and within 35 days of testing;
(b) Water can inhibit an analyser's ability to properly measure the exhaust component of interest and thus is sometimes removed before the sample gas reaches the analyser. For example water can negatively interfere with a CLD's NOx response through collisional quenching and can positively interfere with an NDIR analyser by causing a response similar to CO;
(c) The sample dryer shall meet the specifications as determined in paragraph 9.3.2.3.1. for dew point, Tdew, and absolute pressure, ptotal, downstream of the osmotic-membrane dryer or thermal chiller;
(d) The following sample dryer verification procedure method shall be used to determine sample dryer performance, or good engineering judgment shall be used to develop a different protocol:
(i) PTFE or stainless steel tubing shall be used to make necessary connections;
(ii) N2 or purified air shall be humidified by bubbling it through distilled water in a sealed vessel that humidifies the gas to the highest sample dew point that is estimated during emission sampling;
(iii) The humidified gas shall be introduced upstream of the sample dryer;
(iv) The humidified gas temperature downstream of the vessel shall be maintained at least 5 ºC above its dew point;
(v) The humidified gas dew point, Tdew, and pressure, ptotal, shall be measured as close as possible to the inlet of the sample dryer to verify that the dew point is the highest that was estimated during emission sampling;
(vi) The humidified gas dew point, Tdew, and pressure, ptotal, shall be measured as close as possible to the outlet of the sample dryer;
(vii) The sample dryer meets the verification if the result of sub- paragraphs (d) (vi) of this paragraph is less than the dew point
Annex 4B
corresponding to the sample dryer specifications as determined in paragraph 9.3.2.3.1. plus 2 °C or if the mol fraction from sub- paragraphs (d) (vi) is less than the corresponding sample dryer specifications plus 0.002 mol/mol or 0.2 volume per cent. Note for this verification, sample dew point is expressed in absolute temperature, Kelvin.
Periodic calibration of the partial flow PM and associated raw exhaust gas measurement systems
Specifications for differential flow measurement
For partial flow dilution systems to extract a proportional raw exhaust sample, the accuracy of the sample flow qmp is of special concern, if not measured directly, but determined by differential flow measurement: qmp = qmdew – qmdw (8-1) where: qmp = sample mass flow rate of exhaust gas into partial flow dilution system qmdw = dilution air mass flow rate (on wet basis) qmdew = diluted exhaust gas mass flow rate on wet basis In this case, the maximum error of the difference shall be such that the accuracy of qmp is within ±5 per cent when the dilution ratio is less than 15. It can be calculated by taking root-mean-square of the errors of each instrument. Acceptable accuracies of qmp can be obtained by either of the following methods:
(a) The absolute accuracies of qmdew and qmdw are ±0.2 per cent which guarantees an accuracy of qmp of ≤ 5 per cent at a dilution ratio of 15. However, greater errors will occur at higher dilution ratios;
(b) Calibration of qmdw relative to qmdew is carried out such that the same accuracies for qmp as in (a) are obtained. For details see paragraph 8.1.8.6.2;
(c) The accuracy of qmp is determined indirectly from the accuracy of the dilution ratio as determined by a tracer gas, e.g. CO2. Accuracies equivalent to method (a) for qmp are required;
(d) The absolute accuracy of qmdew and qmdw is within ±2 per cent of full scale, the maximum error of the difference between qmdew and qmdw is within 0.2 per cent and the linearity error is within ±0.2 per cent of the highest qmdew observed during the test.
Calibration of differential flow measurement
The partial flow dilution system to extract a proportional raw exhaust sample shall be periodically calibrated with an accurate flow-meter traceable to international and/or national standards. The flow-meter or the flow measurement instrumentation shall be calibrated in one of the following procedures, such that the probe flow qmp into the tunnel shall fulfil the accuracy requirements of paragraph 8.1.8.6.1.
Annex 4B
(a) The flow-meter for qmdw shall be connected in series to the flow-meter for qmdew, the difference between the two flow-meters shall be calibrated for at least 5 set points with flow values equally spaced between the lowest qmdw value used during the test and the value of qmdew used during the test. The dilution tunnel may be bypassed;
(b) A calibrated flow device shall be connected in series to the flow-meter for qmdew and the accuracy shall be checked for the value used for the test. The calibrated flow device shall be connected in series to the flow- meter for qmdw, and the accuracy shall be checked for at least 5 settings corresponding to dilution ratio between 3 and 15, relative to qmdew used during the test;
(c) The transfer line TL (see Figure 9.2) shall be disconnected from the exhaust and a calibrated flow measuring device with a suitable range to measure qmp shall be connected to the transfer line. qmdew shall be set to the value used during the test, and qmdw shall be sequentially set to at least 5 values corresponding to dilution ratios between 3 and 15. Alternatively, a special calibration flow path may be provided, in which the tunnel is bypassed, but the total and dilution air flow is passed through the corresponding meters as in the actual test;
(d) A tracer gas, shall be fed into the exhaust transfer line TL. This tracer gas may be a component of the exhaust gas, like CO2 or NOx. After dilution in the tunnel the tracer gas component shall be measured. This shall be carried out for 5 dilution ratios between 3 and 15. The accuracy of the sample flow shall be determined from the dilution ratio rd: qmp = qmdew / rd (8-2) The accuracies of the gas analysers shall be taken into account to guarantee the accuracy of qmp.
Special requirements for differential flow measurement
A carbon flow check using actual exhaust is strongly recommended for detecting measurement and control problems and verifying the proper operation of the partial flow system. The carbon flow check should be run at least each time a new engine is installed, or something significant is changed in the test cell configuration. The engine shall be operated at peak torque load and speed or any other steady state mode that produces 5 per cent or more of CO2. The partial flow sampling system shall be operated with a dilution factor of about 15 to 1. If a carbon flow check is conducted, the procedure given in Annex 4B Appendix A.4 shall be applied. The carbon flow rates shall be calculated according to equations of Annex 4B Appendix A.4. All carbon flow rates shall agree to within 5 per cent.
Pre-test check
A pre-test check shall be performed within 2 hours before the test run in the following way.
Annex 4B
The accuracy of the flow-meters shall be checked by the same method as used for calibration (see paragraph 8.1.8.6.2.) for at least two points, including flow values of qmdw that correspond to dilution ratios between 5 and 15 for the qmdew value used during the test. If it can be demonstrated by records of the calibration procedure under paragraph 8.1.8.6.2. that the flow-meter calibration is stable over a longer period of time, the pre-test check may be omitted.
Determination of the transformation time
The system settings for the transformation time evaluation shall be the same as during measurement of the test run. The transformation time, defined in An independent reference flow-meter with a measurement range appropriate for the probe flow shall be put in series with and closely coupled to the probe. This flow-meter shall have a transformation time of less than 100 ms for the flow step size used in the response time measurement, with flow restriction sufficiently low as to not affect the dynamic performance of the partial flow dilution system according to good engineering judgment. A step change shall be introduced to the exhaust flow (or air flow if exhaust flow is calculated) input of the partial flow dilution system, from a low flow to at least 90 per cent of full scale. The trigger for the step change shall be the same one used to start the look-ahead control in actual testing. The exhaust flow step stimulus and the flow-meter response shall be recorded at a sample rate of at least 10 Hz. From this data, the transformation time shall be determined for the partial flow dilution system, which is the time from the initiation of the step stimulus to the 50 per cent point of the flow-meter response. In a similar manner, the transformation times of the qmp signal (i.e. sample flow of exhaust gas into partial flow dilution system) and of the qmew,i signal (i.e. the exhaust gas mass flow rate on wet basis supplied by the exhaust flow-meter) shall be determined. These signals are used in the regression checks performed after each test (see paragraph 8.2.1.2.). The calculation shall be repeated for at least 5 rise and fall stimuli, and the results shall be averaged. The internal transformation time (<100 ms) of the reference flow-meter shall be subtracted from this value. In the case that the system in accordance with paragraph 8.2.1.2. requires the "look-ahead" method, this is the "look-ahead" value of the partial flow dilution system to be applied in accordance with paragraph 8.2.1.2.
Vacuum-side leak verification
Scope and frequency
Upon initial sampling system installation, after major maintenance such as pre- filter changes, and within 8 hours prior to each duty-cycle sequence, it shall be verified that there are no significant vacuum-side leaks using one of the leak tests described in this section. This verification does not apply to any full-flow portion of a CVS dilution system.
Measurement principles
A leak may be detected either by measuring a small amount of flow when there shall be zero flow, by detecting the dilution of a known concentration of span gas when it flows through the vacuum side of a sampling system or by measuring the pressure increase of an evacuated system.
Annex 4B
Low-flow leak test
A sampling system shall be tested for low-flow leaks as follows:
(a) The probe end of the system shall be sealed by taking one of the following steps:
(i) The end of the sample probe shall be capped or plugged;
(ii) The transfer line shall be disconnected at the probe and the transfer line capped or plugged;
(iii) A leak-tight valve in-line between a probe and transfer line shall be closed;
(b) All vacuum pumps shall be operated. After stabilizing, it shall be verified that the flow through the vacuum-side of the sampling system is less than 0.5 per cent of the system's normal in-use flow rate. Typical analyser and bypass flows may be estimated as an approximation of the system's normal in-use flow rate.
Dilution-of-span-gas leak test
Any gas analyser may be used for this test. If a FID is used for this test, any HC contamination in the sampling system shall be corrected according to Annexes A.7 and A.8 on HC and NMHC determination. Misleading results shall be avoided by using only analysers that have a repeatability of 0.5 per cent or better at the span gas concentration used for this test. The vacuum side leak check shall be performed as follows:
(a) A gas analyser shall be prepared as it would be for emission testing;
(b) Span gas shall be supplied to the analyser port and it shall be verified that the span gas concentration is measured within its expected measurement accuracy and repeatability;
(c) Overflow span gas shall be routed to one of the following locations in the sampling system:
(i) The end of the sample probe;
(ii) The transfer line shall be disconnected at the probe connection, and the span gas overflown at the open end of the transfer line;
(iii) A three-way valve installed in-line between a probe and its transfer line;
(d) It shall be verified that the measured overflow span gas concentration is within ±0.5 per cent of the span gas concentration. A measured value lower than expected indicates a leak, but a value higher than expected may indicate a problem with the span gas or the analyser itself. A measured value higher than expected does not indicate a leak.
Vacuum-decay leak test
To perform this test a vacuum shall be applied to the vacuum-side volume of the sampling system and the leak rate of the system shall be observed as a decay in the applied vacuum. To perform this test the vacuum-side volume of the sampling system shall be known to within ±10 per cent of its true volume.
Annex 4B
For this test measurement instruments that meet the specifications of paragraphs 8.1. and 9.4. shall also be used. A vacuum-decay leak test shall be performed as follows:
(a) The probe end of the system shall be sealed as close to the probe opening as possible by taking one of the following steps:
(i) The end of the sample probe shall be capped or plugged;
(ii) The transfer line at the probe shall be disconnected and the transfer line capped or plugged;
(iii) A leak-tight valve in-line between a probe and transfer line shall be closed;
(b) All vacuum pumps shall be operated. A vacuum shall be drawn that is representative of normal operating conditions. In the case of sample bags, it is recommended that the normal sample bag pump-down procedure be repeated twice to minimize any trapped volumes;
(c) The sample pumps shall be turned off and the system sealed. The absolute pressure of the trapped gas and optionally the system absolute temperature shall be measured and recorded. Sufficient time shall be allowed for any transients to settle and long enough for a leak at 0.5 per cent to have caused a pressure change of at least 10 times the resolution of the pressure transducer. The pressure and optionally temperature shall be recorded once again;
(d) The leak flow rate based on an assumed value of zero for pumped-down bag volumes and based on known values for the sample system volume, the initial and final pressures, optional temperatures, and elapsed time shall be calculated. It shall be verified that the vacuum-decay leak flow rate is less than 0.5 per cent of the system's normal in-use flow rate as follows: ⎛ p2 p1 ⎞ ⎜ − ⎟ Vvac ⎝ T2 T1 ⎠ qV leak = (8-3) R ( t2 − t1 ) where: qVleak = vacuum-decay leak rate [mol/s]
Vvac = geometric volume of the vacuum-side of the sampling system [m3] R = molar gas constant [J/(mol·K)] p2 = vacuum-side absolute pressure at time t2 [Pa] T2 = vacuum-side absolute temperature at time t2 [K] p1 = vacuum-side absolute pressure at time t1 [Pa] T1 = vacuum-side absolute temperature at time t1 [K] t2 = time at completion of vacuum-decay leak verification test [s] t1 = time at start of vacuum-decay leak verification test [s]
Annex 4B
CO and CO2 measurements
H2O interference verification for CO2 NDIR analysers
Scope and frequency
If CO2 is measured using an NDIR analyser, the amount of H2O interference shall be verified after initial analyser installation and after major maintenance.
Measurement principles
H2O can interfere with an NDIR analyser's response to CO2. If the NDIR analyser uses compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously these other measurements shall be conducted to test the compensation algorithms during the analyser interference verification.
System requirements
A CO2 NDIR analyser shall have an H2O interference that is within (0.0 ± 0.4) mmol/mol (of the expected mean CO2 concentration).
Procedure
The interference verification shall be performed as follows:
(a) The CO2 NDIR analyser shall be started, operated, zeroed, and spanned as it would be before an emission test;
(b) A humidified test gas shall be created by bubbling zero air that meets the specifications in paragraph 9.5.1. through distilled water in a sealed vessel. If the sample is not passed through a dryer, control the vessel temperature to generate an H2O level at least as high as the maximum expected during testing. If the sample is passed through a dryer during testing, control the vessel temperature to generate an H2O level at least as high as the level determined in paragraph 9.3.2.3.1.;
(c) The humidified test gas temperature shall be maintained at least 5 °C above its dew point downstream of the vessel;
(d) The humidified test gas shall be introduced into the sampling system. The humidified test gas may be introduced downstream of any sample dryer, if one is used during testing;
(e) The water mole fraction, xH2O, of the humidified test gas shall be measured, as close as possible to the inlet of the analyser. For example, dew point, Tdew, and absolute pressure ptotal, shall be measured to calculate xH2O;
(f) Good engineering judgment shall be used to prevent condensation in the transfer lines, fittings, or valves from the point where xH2O is measured to the analyser;
(g) Time shall be allowed for the analyser response to stabilize. Stabilization time shall include time to purge the transfer line and to account for analyser response;
(h) While the analyser measures the sample's concentration, 30 s of sampled data shall be recorded. The arithmetic mean of this data shall be calculated. The analyser meets the interference verification if this value is within (0.0 ± 0.4) mmol/mol
Annex 4B
H2O and CO2 interference verification for CO NDIR analysers
Scope and frequency
If CO is measured using an NDIR analyser, the amount of H2O and CO2 interference shall be verified after initial analyser installation and after major maintenance.
Measurement principles
H2O and CO2 can positively interfere with an NDIR analyser by causing a response similar to CO. If the NDIR analyser uses compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously these other measurements shall be conducted to test the compensation algorithms during the analyser interference verification.
System requirements
A CO NDIR analyser shall have combined H2O and CO2 interference that is within ±2 per cent of the expected mean concentration of CO.
Procedure
The interference verification shall be performed as follows:
(a) The CO NDIR analyser shall be started, operated, zeroed, and spanned as it would be before an emission test;
(b) A humidified CO2 test gas shall be created by bubbling a CO2 span gas through distilled water in a sealed vessel. If the sample is not passed through a dryer, the vessel temperature shall be controlled to generate an H2O level at least as high as the maximum expected during testing. If the sample is passed through a dryer during testing, the vessel temperature shall be controlled to generate an H2O level at least as high as the level determined in paragraph 8.1.8.5.8. A CO2 span gas concentration shall be used at least as high as the maximum expected during testing;
(c) The humidified CO2 test gas shall be introduced into the sampling system. The humidified CO2 test gas may be introduced downstream of any sample dryer, if one is used during testing;
(d) The water mole fraction, xH2O, of the humidified test gas shall be measured, as close as possible to the inlet of the analyser. For example, dew point, Tdew, and absolute pressure ptotal, shall be measured to calculate xH2O;
(e) Good engineering judgment shall be used to prevent condensation in the transfer lines, fittings, or valves from the point where xH2O is measured to the analyser;
(f) Time shall be allowed for the analyser response to stabilize;
(g) While the analyser measures the sample's concentration, its output shall be recorded for 30 s. The arithmetic mean of this data shall be calculated;
(h) The analyser meets the interference verification if the result of sub- paragraph (g) of this section meets the tolerance in paragraph 8.1.9.2.3.;
Annex 4B
(i) Interference procedures for CO2 and H2O may be also run separately. If the CO2 and H2O levels used are higher than the maximum levels expected during testing, each observed interference value shall be scaled down by multiplying the observed interference by the ratio of the maximum expected concentration value to the actual value used during this procedure. Separate interference procedures concentrations of H2O (down to 0.025 mol/mol H2O content) that are lower than the maximum levels expected during testing may be run, but the observed H2O interference shall be scaled up by multiplying the observed interference by the ratio of the maximum expected H2O concentration value to the actual value used during this procedure. The sum of the two scaled interference values shall meet the tolerance in paragraph 8.1.9.2.3.
Hydrocarbon measurements
FID optimization and verification
Scope and frequency
For all FID analysers, the FID shall be calibrated upon initial installation. The calibration shall be repeated as needed using good engineering judgment. The following steps shall be performed for a FID that measures HC:
(a) A FID's response to various hydrocarbons shall be optimized after initial analyser installation and after major maintenance. FID response to propylene and toluene shall be between 0.9 and 1.1 relative to propane;
(b) A FID's methane (CH4) response factor shall be determined after initial analyser installation and after major maintenance as described in paragraph 8.1.10.1.4. of this section;
(c) Methane (CH4) response shall be verified within 185 days before testing.
Calibration
Good engineering judgment shall be used to develop a calibration procedure, such as one based on the FID-analyser manufacturer's instructions and recommended frequency for calibrating the FID. For a FID that measures HC, it shall be calibrated using C3H8 calibration gases that meet the specifications of paragraph 9.5.1. For a FID that measures CH4, it shall be calibrated using CH4 calibration gases that meet the specifications of paragraph 9.5.1. Regardless of the calibration gas composition, it shall be calibrated on a carbon number basis of one (C1).
HC FID response optimization
This procedure is only for FID analysers that measure HC.
(a) Instrument manufacturer requirements and good engineering judgment shall be used for initial instrument start-up and basic operating adjustment using FID fuel and zero air. Heated FIDs shall be within their required operating temperature ranges. FID response shall be optimized to meet the requirement of the hydrocarbon response factors and the oxygen interference check according to sub-paragraph (a) of paragraph 8.1.10.1.1. and paragraph 8.1.10.2. at the most common analyser range expected during emission testing. Higher analyser range may be used according to the instrument manufacturer's recommendation
Annex 4B
and good engineering judgment in order to optimize FID accurately, if the common analyser range is lower than the minimum range for the optimization specified by the instrument manufacturer;
(b) Heated FIDs shall be within their required operating temperature ranges. FID response shall be optimized at the most common analyser range expected during emission testing. With the fuel and airflow rates set at the manufacturer's recommendations, a span gas shall be introduced to the analyser;
(c) The following step from (1) to (4) or the procedure instructed by the instrument manufacturer shall be taken for optimization. The procedures outlined in SAE paper No. 770141 may be optionally used for optimization;
(i) The response at a given fuel flow shall be determined from the difference between the span gas response and the zero gas response;
(ii) The fuel flow shall be incrementally adjusted above and below the manufacturer's specification. The span and zero response at these fuel flows shall be recorded;
(iii) The difference between the span and zero response shall be plotted and the fuel flow adjusted to the rich side of the curve. This is the initial flow rate setting which may need further optimization depending on the results of the hydrocarbon response factors and the oxygen interference check according to sub-paragraph (a) of paragraph 8.1.10.1.1. and paragraph 8.1.10.2;
(iv) If the oxygen interference or the hydrocarbon response factors do not meet the following specifications, the airflow shall be incrementally adjusted above and below the manufacturer's specifications, repeating sub-paragraph (a) of paragraph 8.1.10.1.1. and paragraph 8.1.10.2 for each flow;
(d) The optimum flow rates and/or pressures for FID fuel and burner air shall be determined, and they shall be sampled and recorded for future reference.
HC FID CH4 response factor determination
This procedure is only for FID analysers that measure HC. Since FID analysers generally have a different response to CH4 versus C3H8, each THC FID analyser's CH4 response factor, RFCH4[THC-FID] shall be determined, after FID optimization. The most recent RFCH4[THC-FID] measured according to this paragraph shall be used in the calculations for HC determination described in Annex 4B Appendix A.7 (molar based approach) or Annex 4B Appendix A.8 (mass based approach) to compensate for CH4 response. RFCH4[THC-FID] shall be determined as follows, noting that RFCH4[THC-FID] is not determined for FIDs that are calibrated and spanned using CH4 with a non-methane cutter:
(a) A C3H8 span gas concentration shall be selected to span the analyser before emission testing. Only span gases that meet the specifications of paragraph 9.5.1. shall be selected and the C3H8 concentration of the gas shall be recorded;
Annex 4B
(b) A CH4 span gas that meets the specifications of paragraph 9.5.1. shall be selected and the CH4 concentration of the gas shall be recorded,
(c) The FID analyser shall be operated according to the manufacturer's instructions;
(d) It shall be confirmed that the FID analyser has been calibrated using C3H8. Calibration shall be performed on a carbon number basis of one (C1);
(e) The FID shall be zeroed with a zero gas used for emission testing;
(f) The FID shall be spanned with the selected C3H8 span gas;
(g) The selected CH4 span gas shall be introduced at the sample port of the FID analyser, the CH4 span gas that has been selected under sub- paragraph (b) of this paragraph;
(h) The analyser response shall be stabilized. Stabilization time may include time to purge the analyser and to account for its response;
(i) While the analyser measures the CH4 concentration, 30 s of sampled data shall be recorded and the arithmetic mean of these values shall be calculated;
(j) The mean measured concentration shall be divided by the recorded span concentration of the CH4 calibration gas. The result is the FID analyser's response factor for CH4, RFCH4[THC-FID].
HC FID methane (CH4) response verification
This procedure is only for FID analysers that measure HC. If the value of RFCH4[THC-FID] from paragraph 8.1.10.1.4. is within ±5.0 per cent of its most recent previously determined value, the HC FID passes the methane response verification.
(a) It shall be first verified that the pressures and / or flow rates of FID fuel, burner air, and sample are each within ±0.5 per cent of their most recent previously recorded values, as described in paragraph 8.1.10.1.3. of this section. If these flow rates have to be adjusted, a new RFCH4[THC-FID] shall be determined as described in paragraph 8.1.10.1.4. of this section. It should be verified that the value of RFCH4[THC-FID] determined is within the tolerance specified in this paragraph 8.1.10.1.5.;
(b) If RFCH4[THC-FID] is not within the tolerance specified in this paragraph 8.1.10.1.5., the FID response shall be re-optimized as described in paragraph 8.1.10.1.3. of this section;
(c) A new RFCH4[THC-FID] shall be determined as described in paragraph 8.1.10.1.4. of this section. This new value of RFCH4[THC-FID] shall be used in the calculations for HC determination, as described in Annex 4B, Appendix A.7 (molar based approach) or Annex 4B, Appendix A.8 (mass based approach).
Non-stoichiometric raw exhaust FID O2 interference verification
Scope and frequency
If FID analysers are used for raw exhaust measurements, the amount of FID O2 interference shall be verified upon initial installation and after major maintenance.
Annex 4B
Measurement principles
Changes in O2 concentration in raw exhaust can affect FID response by changing FID flame temperature. FID fuel, burner air, and sample flow shall be optimized to meet this verification. FID performance shall be verified with the compensation algorithms for FID O2 interference that is active during an emission test.
System requirements
Any FID analyser used during testing shall meet the FID O2 interference verification according to the procedure in this section.
Procedure
FID O2 interference shall be determined as follows, noting that one or more gas dividers may be used to create reference gas concentrations that are required to perform this verification:
(a) Three span reference gases shall be selected that meet the specifications in paragraph 9.5.1. and contain C3H8 concentration used to span the analysers before emissions testing. Only span gases that meet the specifications in paragraph 9.5.1. CH4 span reference gases may be used for FIDs calibrated on CH4 with a non-methane cutter. The three balance gas concentrations shall be selected such that the concentrations of O2 and N2 represent the minimum and maximum and intermediate O2 concentrations expected during testing. The requirement for using the average O2 concentration can be removed if the FID is calibrated with span gas balanced with the average expected oxygen concentration;
(b) It shall be confirmed that the FID analyser meets all the specifications of paragraph 8.1.10.1.;
(c) The FID analyser shall be started and operated as it would be before an emission test. Regardless of the FID burner's air source during testing, zero air shall be used as the FID burner's air source for this verification;
(d) The analyser shall be set at zero;
(e) The analyser shall be spanned using a span gas that is used during emissions testing;
(f) The zero response shall be checked by using the zero gas used during emission testing. It shall be proceeded to the next step if the mean zero response of 30 s of sampled data is within ±0.5 per cent of the span reference value used in sub-paragraph (e) of this paragraph, otherwise the procedure shall be restarted at sub-paragraph (d) of this paragraph;
(g) The analyser response shall be checked using the span gas that has the minimum concentration of O2 expected during testing. The mean response of 30 s of stabilized sample data shall be recorded as xO2minHC;
(h) The zero response of the FID analyser shall be checked using the zero gas used during emission testing. The next step shall be performed if the mean zero response of 30 s of stabilized sample data is within ±0.5 per cent of the span reference value used in sub-paragraph (e) of this paragraph, otherwise the procedure shall be restarted at sub-paragraph
(d) of this paragraph;
Annex 4B
(i) The analyser response shall be checked using the span gas that has the average concentration of O2 expected during testing. The mean response of 30 s of stabilized sample data shall be recorded as xO2avgHC;
(j) The zero response of the FID analyser shall be checked using the zero gas used during emission testing. The next step shall be performed if the mean zero response of 30 s of stabilized sample data is within ±0.5 per cent of the span reference value used in paragraph (e) of this paragraph, otherwise the procedure shall be restarted at paragraph (d) of this paragraph;
(k) The analyser response shall be checked using the span gas that has the maximum concentration of O2 expected during testing. The mean response of 30 s of stabilized sample data shall be recorded as xO2maxHC;
(l) The zero response of the FID analyser shall be checked using the zero gas used during emission testing. The next step shall be performed if the mean zero response of 30 s of stabilized sample data is within ±0.5 per cent of the span reference value used in paragraph (e) of this paragraph, otherwise the procedure at paragraph (d) of this paragraph shall be restarted;
(m) The percent difference between xO2maxHC and its reference gas concentration shall be calculated. The percent difference between xO2avgHC and its reference gas concentration shall be calculated. The percent difference between xO2minHC and its reference gas concentration shall be calculated. The maximum percent difference of the three shall be determined. This is the O2 interference;
(n) If the O2 interference is within ±3 per cent, the FID passes the O2 interference verification; otherwise one or more of the following need to be performed to address the deficiency:
(i) The verification shall be repeated to determine if a mistake was made during the procedure;
(ii) The zero and span gases for emission testing shall be selected that contain higher or lower O2 concentrations and the verification shall be repeated;
(iii) The FID burner air, fuel, and sample flow rates shall be adjusted. Note that if these flow rates are adjusted on a THC FID to meet the O2 interference verification, the RFCH4 shall be reset for the next RFCH4 verification. The O2 interference verification shall be repeated after adjustment and RFCH4 shall be determined;
(iv) The FID shall be repaired or replaced and the O2 interference verification shall be repeated.
Non-methane cutter penetration fractions
Scope and frequency
If a FID analyser and a non-methane cutter (NMC) is used to measure methane (CH4), the non-methane cutter's conversion efficiencies of methane, ECH4, and ethane, EC2H6 shall be determined. As detailed in this paragraph, these conversion efficiencies may be determined as a combination of NMC conversion efficiencies and FID analyser response factors, depending on the particular NMC and FID analyser configuration.
Annex 4B
This verification shall be performed after installing the non-methane cutter. This verification shall be repeated within 185 days of testing to verify that the catalytic activity of the cutter has not deteriorated.
Measurement principles
A non-methane cutter is a heated catalyst that removes non-methane hydrocarbons from the exhaust stream before the FID analyser measures the remaining hydrocarbon concentration. An ideal non-methane cutter would have a methane conversion efficiency ECH4 [-] of 0 (that is, a methane penetration fraction, PFCH4, of 1.000), and the conversion efficiency for all other hydrocarbons would be 1.000, as represented by an ethane conversion efficiency EC2H6 [-] of 1 (that is, an ethane penetration fraction PFC2H6 [-] of 0). The emission calculations in Annex 4B, Appendix A.7 or Annex 4B, Appendix A.8 use this paragraph's measured values of conversion efficiencies ECH4 and EC2H6 to account for less than ideal NMC performance.
System requirements
NMC conversion efficiencies are not limited to a certain range. However, it is recommended that a non-methane cutter is optimized by adjusting its temperature to achieve a ECH4 < 0.15 and a EC2H6 > 0.98 (PFCH4 > 0.85 and PFC2H6 < 0.02) as determined by paragraph 8.1.10.3.4., as applicable. If adjusting NMC temperature does not result in achieving these specifications, it is recommended that the catalyst material is replaced. The most recently determined conversion values from this section shall be used to calculate HC emissions according to Annexes A.7-A.8 as applicable.
Procedure
Any one of the procedures specified in paragraphs 8.1.10.3.4.1., 8.1.10.3.4.2. and 8.1.10.3.4.3. is recommended. An alternative method recommended by the instrument manufacturer may be used.
Procedure for a FID calibrated with the NMC
If a FID is always calibrated to measure CH4 with the NMC, then the FID shall be spanned with the NMC using a CH4 span gas, the product of that FID's CH4 response factor and CH4 penetration fraction, RFPFCH4[NMC-FID], shall be set equal to 1.0 (i.e. efficiency ECH4 [-] is set to 0) for all emission calculations, and the combined ethane (C2H6) response factor and penetration fraction, RFPFC2H6[NMC-FID] (and efficiency EC2H6 [-]) shall be determined as follows:
(a) Both a CH4 gas mixture and a C2H6 analytical gas mixture shall be selected meeting the specifications of paragraph 9.5.1. Both a CH4 concentration for spanning the FID during emission testing and a C2H6 concentration that is typical of the peak NMHC concentration expected at the hydrocarbon standard or equal to THC analyser's span value shall be selected;
(b) The non-methane cutter shall be started, operated, and optimized according to the manufacturer's instructions, including any temperature optimization;
(c) It shall be confirmed that the FID analyser meets all the specifications of paragraph 8.1.10.1.;
Annex 4B
(d) The FID analyser shall be operated according to the manufacturer's instructions;
(e) CH4 span gas shall be used to span the FID with the cutter. The FID shall be spanned on a C1 basis. For example, if the span gas has a CH4 reference value of 100 µmol/mol, the correct FID response to that span gas is 100 µmol/mol because there is one carbon atom per CH4 molecule;
(f) The C2H6 analytical gas mixture shall be introduced upstream of the non-methane cutter;
(g) The analyser response shall be stabilized. Stabilization time may include time to purge the non-methane cutter and to account for the analyser's response;
(h) While the analyser measures a stable concentration, 30 s of sampled data shall be recorded and the arithmetic mean of these data points shall be calculated;
(i) The mean shall be divided by the reference value of C2H6, converted to a C1 basis. The result is the C2H6 combined response factor and penetration fraction, RFPFC2H6[NMC-FID], equivalent to (1 - EC2H6 [-]). This combined response factor and penetration fraction and the product of the CH4 response factor and CH4 penetration fraction, RFPFCH4[NMC-FID], which is set equal to 1.0, in emission calculations shall be used according to A.7 or A.8, as applicable.
Procedure for a FID calibrated with propane bypassing the NMC
If a FID is used with an NMC that is calibrated with propane, C3H8, by bypassing the NMC, penetrations fractions PFC2H6[NMC-FID] and PFCH4[NMC-FID] shall be determined as follows:
(a) A CH4 gas mixture and a C2H6 analytical gas mixture shall be selected meeting the specifications of paragraph 9.5.1. with the CH4 concentration typical of its peak concentration expected at the hydrocarbon standard and the C2H6 concentration typical of the peak total hydrocarbon (THC) concentration expected at the hydrocarbon standard or the THC analyser span value;
(b) The non-methane cutter shall be started and operated according to the manufacturer's instructions, including any temperature optimization;
(c) It shall be confirmed that the FID analyser meets all the specifications of paragraph 8.1.10.1.;
(d) The FID analyser shall be operated according to the manufacturer's instructions;
(e) The FID shall be zeroed and spanned as it would be during emission testing. The FID shall be spanned by bypassing the cutter and by using C3H8 span gas to span the FID. The FID shall be spanned on a C1 basis;
(f) The C2H6 analytical gas mixture shall be introduced upstream of the non-methane cutter at the same point the zero gas was introduced;
(g) Time shall be allowed for the analyser response to stabilize. Stabilization time may include time to purge the non-methane cutter and to account for the analyser's response;
Annex 4B
(h) While the analyser measures a stable concentration, 30 s of sampled data shall be recorded and the arithmetic mean of these data points shall be calculated;
(i) The flow path shall be rerouted to bypass the non-methane cutter, the C2H6 analytical gas mixture shall be introduced to the bypass, and the steps in sub-paragraphs (g) through (h) of this paragraph shall be repeated;
(j) The mean C2H6 concentration measured through the non-methane cutter shall be divided by the mean concentration measured after bypassing the non-methane cutter. The result is the C2H6 penetration fraction, PFC2H6[NMC-FID], that is equivalent to (1- EC2H6 [-]). This penetration fraction shall be used according to A.7 or A.8, as applicable;
(k) The steps in sub-paragraphs (f) through (j) of this paragraph shall be repeated, but with the CH4 analytical gas mixture instead of C2H6. The result will be the CH4 penetration fraction, PFCH4[NMC-FID] (equivalent to (1- ECH4 [-])). This penetration fraction shall be used according to Annexes A.7-A.8, as applicable.
Procedure for a FID calibrated with methane, bypassing the NMC
If a FID is used with an NMC that is calibrated with methane, CH4, by bypassing the NMC, determine its combined ethane (C2H6) response factor and penetration fraction, RFPFC2H6[NMC-FID] , as well as its CH4 penetration fraction, PFCH4[NMC-FID], as follows:
(a) CH4 and C2H6 analytical gas mixtures shall be selected that meet the specifications of paragraph 9.5.1., with the CH4 concentration typical of its peak concentration expected at the hydrocarbon standard and the C2H6 concentration typical of the peak total hydrocarbon (THC) concentration expected at the hydrocarbon standard or the THC analyser span value;
(b) The non-methane cutter shall be started and operated according to the manufacturer's instructions, including any temperature optimization;
(c) It shall be confirmed that the FID analyser meets all the specifications of paragraph 8.1.10.1.;
(d) The FID analyser shall be started and operated according to the manufacturer's instructions;
(e) The FID shall be zeroed and spanned as it would during emission testing. The FID shall be spanned with CH4 span gas by bypassing the cutter. Note that the FID shall be spanned on a C1 basis. For example, if the span gas has a methane reference value of 100 µmol/mol, the correct FID response to that span gas is 100 µmol/mol because there is one carbon atom per CH4 molecule;
(f) The C2H6 analytical gas mixture shall be introduced upstream of the non-methane cutter at the same point the zero gas was introduced;
(g) Time shall be allowed for the analyser response to stabilize. Stabilization time may include time to purge the non-methane cutter and to account for the analyser's response;
Annex 4B
(h) 30 s of sampled data shall be recorded while the analyser measures a stable concentration. The arithmetic mean of these data points shall be calculated;
(i) The flow path to bypass the non-methane cutter shall be rerouted, the C2H6 analytical gas mixture shall be introduced to the bypass, and the steps in sub-paragraphs (g) and (h) of this paragraph shall be repeated;
(j) The mean C2H6 concentration measured through the non-methane cutter shall be divided by the mean concentration measured after bypassing the non-methane cutter. The result is the C2H6 combined response factor and penetration fraction, RFPFC2H6[NMC-FID]. This combined response factor and penetration fraction shall be used according to Annexes A.7 and A.8, as applicable;
(k) The steps in sub-paragraphs (f) through (j) of this paragraph shall be repeated, but with the CH4 analytical gas mixture instead of C2H6. The result will be the CH4 penetration fraction, PFCH4[NMC-FID]. This penetration fraction shall be used according to Annexes A.7 and A.8, as applicable.
NOx measurements
CLD CO2 and H2O quench verification
Scope and frequency
If a CLD analyser is used to measure NOx, the amount of H2O and CO2 quench shall be verified after installing the CLD analyser and after major maintenance.
Measurement principles
H2O and CO2 can negatively interfere with a CLD's NOx response by collisional quenching, which inhibits the chemiluminescent reaction that a CLD utilizes to detect NOx. This procedure and the calculations in paragraph 8.1.11.2.3. determine quench and scale the quench results to the maximum mole fraction of H2O and the maximum CO2 concentration expected during emission testing. If the CLD analyser uses quench compensation algorithms that utilize H2O and/or CO2 measurement instruments, quench shall be evaluated with these instruments active and with the compensation algorithms applied.
System requirements
For dilute measurement a CLD analyser shall not exceed a combined H2O and CO2 quench of ±2 per cent. For raw measurement a CLD analyser shall not exceed a combined H2O and CO2 quench of ±2 per cent. Combined quench is the sum of the CO2 quench determined as described in paragraph 8.1.11.1.4. and the H2O quench as determined in paragraph 8.1.11.1.5. If these requirements are not met, corrective action shall be taken by repairing or replacing the analyser. Before running emission tests, it shall be verified that the corrective action have successfully restored the analyser to proper functioning.
CO2 quench verification procedure
The following method or the method prescribed by the instrument manufacturer may be used to determine CO2 quench by using a gas divider that
Annex 4B
blends binary span gases with zero gas as the diluent and meets the specifications in paragraph 9.4.5.6., or good engineering judgment shall be used to develop a different protocol:
(a) PTFE or stainless steel tubing shall be used to make necessary connections;
(b) The gas divider shall be configured such that nearly equal amounts of the span and diluent gases are blended with each other;
(c) If the CLD analyser has an operating mode in which it detects NO-only, as opposed to total NOx, the CLD analyser shall be operated in the NO- only operating mode;
(d) A CO2 span gas that meets the specifications of paragraph 9.5.1. and a concentration that is approximately twice the maximum CO2 concentration expected during emission testing shall be used;
(e) An NO span gas that meets the specifications of paragraph 9.5.1. and a concentration that is approximately twice the maximum NO concentration expected during emission testing shall be used. Higher concentration may be used according to the instrument manufacturer's recommendation and good engineering judgement in order to obtain accurate verification, if the expected NO concentration is lower than the minimum range for the verification specified by the instrument manufacturer;
(f) The CLD analyser shall be zeroed and spanned. The CLD analyser shall be spanned with the NO span gas from paragraph (e) of this paragraph through the gas divider. The NO span gas shall be connected to the span port of the gas divider; a zero gas shall be connected to the diluent port of the gas divider; the same nominal blend ratio shall be used as selected in sub-paragraph (b) of this paragraph; and the gas divider's output concentration of NO shall be used to span the CLD analyser. Gas property corrections shall be applied as necessary to ensure accurate gas division;
(g) The CO2 span gas shall be connected to the span port of the gas divider;
(h) The NO span gas shall be connected to the diluents port of the gas divider;
(i) While flowing NO and CO2 through the gas divider, the output of the gas divider shall be stabilized. The CO2 concentration from the gas divider output shall be determined, applying gas property correction as necessary to ensure accurate gas division. This concentration, xCO2act, shall be recorded and it shall be used in the quench verification calculations in paragraph 8.1.11.2.3. As an alternative to using a gas divider, another simple gas blending device may be used. In this case an analyser shall be used to determine CO2 concentration. If a NDIR is used together with a simple gas blending device, it shall meet the requirements of this section and it shall be spanned with the CO2 span gas from sub-paragraph (d) of this section. The linearity of the NDIR analyser has to be checked before over the whole range up to twice of the expected maximum CO2 concentration expected during testing;
Annex 4B
(j) The NO concentration shall be measured downstream of the gas divider with the CLD analyser. Time shall be allowed for the analyser response to stabilize. Stabilization time may include time to purge the transfer line and to account for analyser response. While the analyser measures the sample's concentration, the analyser's output shall be recorded for 30 s. The arithmetic mean concentration shall be calculated from these data, xNOmeas. xNOmeas shall be recorded and it shall be used in the quench verification calculations in paragraph 8.1.11.2.3.;
(k) The actual NO concentration shall be calculated at the gas divider's outlet, xNOact, based on the span gas concentrations and xCO2act according to equation (8-5). The calculated value shall be used in the quench verification calculations in equation (8-4);
(l) The values recorded according to paragraphs 8.1.11.1.4. and 8.1.11.1.5. of this section shall be used to calculate quench as described in paragraph 8.1.11.2.3.
H2O quench verification procedure
The following method or the method prescribed by the instrument manufacturer may be used to determine H2O quench, or good engineering judgment shall be used to develop a different protocol:
(a) PTFE or stainless steel tubing shall be used to make necessary connections;
(b) If the CLD analyser has an operating mode in which it detects NO-only, as opposed to total NOx, the CLD analyser shall be operated in the NO- only operating mode;
(c) A NO span gas shall be used that meets the specifications of paragraph 9.5.1. and a concentration that is near the maximum concentration expected during emission testing. Higher concentration may be used according to the instrument manufacturer's recommendation and good engineering judgement in order to obtain accurate verification, if the expected NO concentration is lower than the minimum range for the verification specified by the instrument manufacturer;
(d) The CLD analyser shall be zeroed and spanned. The CLD analyser shall be spanned with the NO span gas from paragraph (c) of this paragraph, the span gas concentration shall be recorded as xNOdry, and it shall be used in the quench verification calculations in paragraph 8.1.11.2.3.;
(e) The NO span gas shall be humidified by bubbling it through distilled water in a sealed vessel. If the humidified NO span gas sample does not pass through a sample dryer for this verification test, the vessel temperature shall be controlled to generate an H2O level approximately equal to the maximum mole fraction of H2O expected during emission testing. If the humidified NO span gas sample does not pass through a sample dryer, the quench verification calculations in paragraph 8.1.11.2.3. scale the measured H2O quench to the highest mole fraction of H2O expected during emission testing. If the humidified NO span gas sample passes through a dryer for this verification test, the vessel temperature shall be controlled to generate
Annex 4B
an H2O level at least as high as the level determined in paragraph 9.3.2.3.1. For this case, the quench verification calculations in paragraph 8.1.11.2.3. do not scale the measured H2O quench;
(f) The humidified NO test gas shall be introduced into the sample system. It may be introduced upstream or downstream of a sample dryer that is used during emission testing. Depending on the point of introduction, the respective calculation method of sub-paragraph (e) shall be selected. Note that the sample dryer shall meet the sample dryer verification check in paragraph 8.1.8.5.8.;
(g) The mole fraction of H2O in the humidified NO span gas shall be measured. In case a sample dryer is used, the mole fraction of H2O in the humidified NO span gas shall be measured downstream of the sample dryer, xH2Omeas. It is recommended to measure xH2Omeas as close as possible to the CLD analyser inlet. xH2Omeas may be calculated from measurements of dew point, Tdew, and absolute pressure, ptotal;
(h) Good engineering judgment shall be used to prevent condensation in the transfer lines, fittings, or valves from the point where xH2Omeas is measured to the analyser. It is recommended that the system is designed so the wall temperatures in the transfer lines, fittings, and valves from the point where xH2Omeas is measured to the analyser are at least 5 ºC above the local sample gas dew point;
(i) The humidified NO span gas concentration shall be measured with the CLD analyser. Time shall be allowed for the analyser response to stabilize. Stabilization time may include time to purge the transfer line and to account for analyser response. While the analyser measures the sample's concentration, the analyser's output shall be recorded for 30 seconds. The arithmetic mean shall be calculated of these data, xNOwet. xNOwet shall be recorded and used in the quench verification calculations in paragraph 8.1.11.2.3.
CLD quench verification calculations
CLD quench-check calculations shall be performed as described in this paragraph.
Amount of water expected during testing
The maximum expected mole fraction of water during emission testing, xH2Oexp shall be estimated. This estimate shall be made where the humidified NO span gas was introduced in sub-paragraph (f) of paragraph 8.1.11.1.5. When estimating the maximum expected mole fraction of water, the maximum expected water content in combustion air, fuel combustion products, and dilution air (if applicable) shall be considered. If the humidified NO span gas is introduced into the sample system upstream of a sample dryer during the verification test, it is not needed to estimate the maximum expected mole fraction of water and xH2Oexp shall be set equal to xH2Omeas.
Amount of CO2 expected during testing
The maximum expected CO2 concentration during emission testing, xCO2exp shall be estimated. This estimate shall be made at the sample system location where the blended NO and CO2 span gases are introduced according to sub- paragraph (j) of paragraph 8.1.11.1.4. When estimating the maximum expected
Annex 4B
CO2 concentration, the maximum expected CO2 content in fuel combustion products and dilution air shall be considered.
Combined H2O and CO2 quench calculations
Combined H2O and CO2 quench shall be calculated as follows: ⎡⎛ xNOwet ⎞ ⎤ ⎢⎜ 1 − x ⎟ x ⎛x ⎞ xCO2exp ⎥ quench = ⎢⎜ H2Omeas − 1⎟ ⋅ H20exp + ⎜ NOmeas − 1⎟ ⋅ ⎥ ⋅100% (8-4) ⎢⎜ xNOdry ⎟ xH2Omeas ⎝ xNOact ⎠ CO2act ⎥ x ⎢⎜ ⎟ ⎥ ⎣⎝ ⎠ ⎦ where: quench = amount of CLD quench xNOdry = measured concentration of NO upstream of a bubbler, according to sub-paragraph (d) of paragraph 8.1.11.1.5. xNOwet = measured concentration of NO downstream of a bubbler, according to sub-paragraph (i) of paragraph 8.1.11.1.5. xH2Oexp = maximum expected mole fraction of water during emission testing according to paragraph 8.1.11.2.1. xH2Omeas = measured mole fraction of water during the quench verification according to sub-paragraph (g) of paragraph 8.1.11.1.5. xNOmeas = measured concentration of NO when NO span gas is blended with CO2 span gas, according to sub-paragraph (j) of paragraph 8.1.11.1.4. xNOact = actual concentration of NO when NO span gas is blended with CO2 span gas, according to sub-paragraph (k) of paragraph 8.1.11.1.4. and calculated according to equation (8-5) xCO2exp = maximum expected concentration of CO2 during emission testing, according to paragraph 8.1.11.2.2. xCO2act = actual concentration of CO2 when NO span gas is blended with CO2 span gas, according to sub-paragraph (i) of paragraph 8.1.11.1.4.
⎛ x ⎞ xNOact = ⎜1 − CO2act ⎟ ⋅ xNOspan (8-5) ⎜ xCO2span ⎟ ⎝ ⎠ where: xNOspan = the NO span gas concentration input to the gas divider, according to sub-paragraph (e) of paragraph 8.1.11.1.4. xCO2span = the CO2 span gas concentration input to the gas divider, according to sub-paragraph (d) of paragraph 8.1.11.1.4.
Annex 4B
NDUV analyser HC and H2O interference verification
Scope and frequency
If NOx is measured using an NDUV analyser, the amount of H2O and hydrocarbon interference shall be verified after initial analyser installation and after major maintenance.
Measurement principles
Hydrocarbons and H2O can positively interfere with a NDUV analyser by causing a response similar to NOx. If the NDUV analyser uses compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously such measurements shall be conducted to test the algorithms during the analyser interference verification.
System requirements
A NOx NDUV analyser shall have combined H2O and HC interference within ±2 per cent of the mean concentration of NOx.
Procedure
The interference verification shall be performed as follows:
(a) The NOx NDUV analyser shall be started, operated, zeroed, and spanned according to the instrument manufacturer's instructions;
(b) It is recommended to extract engine exhaust to perform this verification. A CLD shall be used that meets the specifications of paragraph 9.4. to quantify NOx in the exhaust. The CLD response shall be used as the reference value. Also HC shall be measured in the exhaust with a FID analyser that meets the specifications of paragraph 9.4. The FID response shall be used as the reference hydrocarbon value;
(c) Upstream of any sample dryer, if one is used during testing, the engine exhaust shall be introduced into the NDUV analyser;
(d) Time shall be allowed for the analyser response to stabilize. Stabilization time may include time to purge the transfer line and to account for analyser response;
(e) While all analysers measure the sample's concentration, 30 s of sampled data shall be recorded, and the arithmetic means for the three analysers calculated;
(f) The CLD mean shall be subtracted from the NDUV mean;
(g) This difference shall be multiplied by the ratio of the expected mean HC concentration to the HC concentration measured during the verification. The analyser meets the interference verification of this paragraph if this result is within ±2 per cent of the NOx concentration expected at the standard:
⎛ xHC,e xp ⎞ xNOx,CLD,meas − xNOx,NDUV,meas ⋅ ⎜ ⎜x ⎟⎟ ≤ 2% ⋅ ( xNOx,exp ) (8-6) ⎝ HC,meas ⎠
Annex 4B
where:
xNOx,CLD,meas = the mean concentration of NOx measured by CLD [µmol/mol] or [ppm]
xNOx,NDUV,meas = the mean concentration of NOx measured by NDUV [µmol/mol] or [ppm]
xHC,meas = the mean concentration of HC measured [µmol/mol] or [ppm]
xHC,exp = the mean concentration of HC expected at the standard [µmol/mol] or [ppm]
xNOx,exp = the mean concentration of NOx expected at the standard [µmol/mol] or [ppm]
Cooling bath (chiller) requirements
It shall be demonstrated that for the highest expected water vapour concentration Hm, the water removal technique maintains CLD humidity at ≤ 5 g water/kg dry air (or about 0.8 volume per cent H2O), which is 100 per cent relative humidity at 3.9 °C and 101.3 kPa. This humidity specification is also equivalent to about 25 per cent relative humidity at 25 °C and 101.3 kPa. This may be demonstrated by measuring the temperature at the outlet of a thermal dehumidifier, or by measuring humidity at a point just upstream of the CLD.
Cooling bath (chiller) NO2 penetration
Scope and frequency
If a cooling bath (chiller) is used to dry a sample upstream of a NOx measurement instrument, but no NO2-to-NO converter is used upstream of the cooling bath, this verification shall be performed for cooling bath NO2 penetration. This verification shall be performed after initial installation and after major maintenance.
Measurement principles
A cooling bath (chiller) removes water, which can otherwise interfere with a NOx measurement. However, liquid water remaining in an improperly designed cooling bath can remove NO2 from the sample. If a cooling bath is used without an NO2-to-NO converter upstream, it could therefore remove NO2 from the sample prior NOx measurement.
System requirements
The chiller shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO2.
Procedure
The following procedure shall be used to verify chiller performance:
(a) Instrument setup. The analyser and chiller manufacturers' start-up and operating instructions shall be followed. The analyser and chiller shall be adjusted as needed to optimize performance;
Annex 4B
(b) Equipment setup and data collection.
(i) The total NOx gas analyser(s) shall be zeroed and spanned as it would be before emission testing;
(ii) NO2 calibration gas (balance gas of dry air) that has an NO2 concentration that is near the maximum expected during testing shall be selected. Higher concentration may be used according to the instrument manufacturer's recommendation and good engineering judgement in order to obtain accurate verification, if the expected NO2 concentration is lower than the minimum range for the verification specified by the instrument manufacturer;
(iii) This calibration gas shall be overflowed at the gas sampling system's probe or overflow fitting. Time shall be allowed for stabilization of the total NOx response, accounting only for transport delays and instrument response;
(iv) The mean of 30 s of recorded total NOx data shall be calculated and this value recorded as xNOxref;
(v) The flowing the NO2 calibration gas shall be stopped;
(vi) Next the sampling system shall be saturated by overflowing a dew point generator's output, set at a dew point of 50 °C, to the gas sampling system's probe or overflow fitting. The dew point generator's output shall be sampled through the sampling system and chiller for at least 10 minutes until the chiller is expected to be removing a constant rate of water;
(vii) It shall be immediately switched back to overflowing the NO2 calibration gas used to establish xNOxref. It shall be allowed for stabilization of the total NOx response, accounting only for transport delays and instrument response. The mean of 30 s of recorded total NOx data shall be calculated and this value recorded as xNOxmeas;
(viii) xNOxmeas shall be corrected to xNOxdry based upon the residual water vapour that passed through the chiller at the chiller's outlet temperature and pressure;
(c) Performance evaluation. If xNOxdry is less than 95 per cent of xNOxref, the chiller shall be repaired or replaced.
NO2-to-NO converter conversion verification
Scope and frequency
If an analyser is used that measures only NO to determine NOx, an NO2-to-NO converter shall be used upstream of the analyser. This verification shall be performed after installing the converter, after major maintenance and within 35 days before an emission test. This verification shall be repeated at this frequency to verify that the catalytic activity of the NO2-to-NO converter has not deteriorated.
Measurement principles
An NO2-to-NO converter allows an analyser that measures only NO to determine total NOx by converting the NO2 in exhaust to NO.
Annex 4B
System requirements
An NO2-to-NO converter shall allow for measuring at least 95 per cent of the total NO2 at the maximum expected concentration of NO2.
Procedure
The following procedure shall be used to verify the performance of a NO2-to- NO converter:
(a) For the instrument setup the analyser and NO2-to-NO converter manufacturers' start-up and operating instructions shall be followed. The analyser and converter shall be adjusted as needed to optimize performance;
(b) An ozonator's inlet shall be connected to a zero-air or oxygen source and its outlet shall be connected to one port of a 3-way tee fitting. An NO span gas shall be connected to another port and the NO2-to-NO converter inlet shall be connected to the last port;
(c) The following steps shall be taken when performing this check:
(i) The ozonator air shall be set off and the ozonator power shall be turned off and the NO2-to-NO converter shall be set to the bypass mode (i.e., NO mode). Stabilization shall be allowed for, accounting only for transport delays and instrument response;
(ii) The NO and zero-gas flows shall be adjusted so the NO concentration at the analyser is near the peak total NOx concentration expected during testing. The NO2 content of the gas mixture shall be less than 5 per cent of the NO concentration. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value shall be recorded as xNOref. Higher concentration may be used according to the instrument manufacturer's recommendation and good engineering judgement in order to obtain accurate verification, if the expected NO concentration is lower than the minimum range for the verification specified by the instrument manufacturer;
(iii) The ozonator O2 supply shall be turned on and the O2 flow rate adjusted so that the NO indicated by the analyser is about 10 percent less than xNOref. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value recorded as xNO+O2mix;
(iv) The ozonator shall be switched on and the ozone generation rate adjusted so that the NO measured by the analyser is approximately 20 percent of xNOref, while maintaining at least 10 per cent unreacted NO. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value shall be recorded as xNOmeas;
(v) The NOx analyser shall be switched to NOx mode and total NOx measured. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value shall be recorded as xNOxmeas;
Annex 4B
(vi) The ozonator shall be switched off but gas flow through the system shall be maintained. The NOx analyser will indicate the NOx in the NO + O2 mixture. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value shall be recorded as xNOx+O2mix;
(vii) O2 supply shall be turned off. The NOx analyser will indicate the NOx in the original NO-in-N2 mixture. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyser and this value shall be recorded as xNOxref. This value shall be no more than 5 per cent above the xNOref value;
(d) Performance evaluation. The efficiency of the NOx converter shall be calculated by substituting the concentrations obtained into the following equation:
⎛ x −x ⎞ Efficiency [%] = ⎜1 + NOxmeas NOx+O2mix ⎟ ⋅100 (8-7) ⎝ xNO+O2mix − xNOmeas ⎠
(e) If the result is less than 95 per cent, the NO2-to-NO converter shall be repaired or replaced.
PM measurements
PM balance verifications and weighing process verification
Scope and frequency
This paragraph describes three verifications.
(a) Independent verification of PM balance performance within 370 days prior to weighing any filter;
(b) Zero and span of the balance within 12 h prior to weighing any filter;
(c) Verification that the mass determination of reference filters before and after a filter weighing session be less than a specified tolerance.
Independent verification
The balance manufacturer (or a representative approved by the balance manufacturer) shall verify the balance performance within 370 days of testing in accordance with internal audit procedures.
Zeroing and spanning
Balance performance shall be verified by zeroing and spanning it with at least one calibration weight, and any weights that are used shall meet the specifications in paragraph 9.5.2. to perform this verification. A manual or automated procedure shall be used:
(a) A manual procedure requires that the balance shall be used in which the balance shall be zeroed and spanned with at least one calibration weight. If normally mean values are obtained by repeating the weighing process to improve the accuracy and precision of PM measurements, the same process shall be used to verify balance performance;
Annex 4B
(b) An automated procedure is carried out with internal calibration weights that are used automatically to verify balance performance. These internal calibration weights shall meet the specifications in paragraph 9.5.2. to perform this verification.
Reference sample weighing
All mass readings during a weighing session shall be verified by weighing reference PM sample media (e.g. filters) before and after a weighing session. A weighing session may be as short as desired, but no longer than 80 hours, and may include both pre- and post-test mass readings. Successive mass determinations of each reference PM sample media shall return the same value within ±10 µg or ±10 per cent of the expected total PM mass, whichever is higher. Should successive PM sample filter weighing events fail this criterion, all individual test filter mass readings mass readings occurring between the successive reference filter mass determinations shall be invalidated. These filters may be re-weighed in another weighing session. Should a post-test filter be invalidated then the test interval is void. This verification shall be performed as follows:
(a) At least two samples of unused PM sample media shall be kept in the PM-stabilization environment. These shall be used as references. Unused filters of the same material and size shall be selected for use as references;
(b) References shall be stabilized in the PM stabilization environment. References shall be considered stabilized if they have been in the PM- stabilization environment for a minimum of 30 min, and the PM- stabilization environment has been within the specifications of paragraph 9.3.4.4. for at least the preceding 60 min;
(c) The balance shall be exercised several times with a reference sample without recording the values;
(d) The balance shall be zeroed and spanned. A test mass shall be placed on the balance (e.g. calibration weight) and then removed ensuring that the balance returns to an acceptable zero reading within the normal stabilization time;
(e) Each of the reference media (e.g. filters) shall be weighed and their masses recorded. If normally mean values are obtained by repeating the weighing process to improve the accuracy and precision of reference media (e.g. filters) masses, the same process shall be used to measure mean values of sample media (e.g. filters) masses;
(f) The balance environment dew point, ambient temperature, and atmospheric pressure shall be recorded;
(g) The recorded ambient conditions shall be used to correct results for buoyancy as described in paragraph 8.1.12.2. The buoyancy-corrected mass of each of the references shall be recorded;
(h) Each of the reference media's (e.g. filter's) buoyancy-corrected reference mass shall be subtracted from its previously measured and recorded buoyancy-corrected mass;
Annex 4B
(i) If any of the reference filters' observed mass changes by more than that allowed under this paragraph, all PM mass determinations made since the last successful reference media (e.g. filter) mass validation shall be invalidated. Reference PM filters maybe discarded if only one of the filters mass has changed by more than the allowable amount and a special cause for that filter's mass change can be positively identified which would not have affected other in-process filters. Thus the validation can be considered a success. In this case, the contaminated reference media shall not be included when determining compliance with sub-paragraph (j) of this paragraph, but the affected reference filter shall be discarded and replaced;
(j) If any of the reference masses change by more than that allowed under this paragraph 8.1.12.1.4., all PM results that were determined between the two times that the reference masses were determined shall be invalidated. If reference PM sample media is discarded according to sub-paragraph (i) of this paragraph, at least one reference mass difference that meets the criteria in this paragraph 8.1.12.1.4. shall be available. Otherwise, all PM results that were determined between the two times that the reference media (e.g. filters) masses were determined shall be invalidated.
PM sample filter buoyancy correction
General
PM sample filter shall be corrected for their buoyancy in air. The buoyancy correction depends on the sample media density, the density of air, and the density of the calibration weight used to calibrate the balance. The buoyancy correction does not account for the buoyancy of the PM itself, because the mass of PM typically accounts for only (0.01 to 0.10) per cent of the total weight. A correction to this small fraction of mass would be at the most 0.010 per cent. The buoyancy-corrected values are the tare masses of the PM samples. These buoyancy-corrected values of the pre-test filter weighing are subsequently subtracted from the buoyancy-corrected values of the post-test weighing of the corresponding filter to determine the mass of PM emitted during the test.
PM sample filter density
Different PM sample filter have different densities. The known density of the sample media shall be used, or one of the densities for some common sampling media shall be used, as follows:
(a) For PTFE-coated borosilicate glass, a sample media density of 2,300 kg/m3 shall be used;
(b) For PTFE membrane (film) media with an integral support ring of polymethylpentene that accounts for 95 per cent of the media mass, a sample media density of 920 kg/m3 shall be used;
(c) For PTFE membrane (film) media with an integral support ring of PTFE, a sample media density of 2,144 kg/m3 shall be used.
Annex 4B
Air density
Because a PM balance environment shall be tightly controlled to an ambient temperature of (22 ± 1) °C and a dew point of (9.5 ± 1) °C, air density is primarily function of atmospheric pressure. Therefore a buoyancy correction is specified that is only a function of atmospheric pressure.
Calibration weight density
The stated density of the material of the metal calibration weight shall be used.
Correction calculation
The PM sample filter shall be corrected for buoyancy using the following equations: ⎛ ρair ⎞ ⎜ 1− ρ ⎟ mcor = muncor ⋅ ⎜ weight ⎟ (8-8) ⎜ ρair ⎟ ⎜ 1− ρ ⎟ ⎝ media ⎠
where: mcor = PM sample filter mass corrected for buoyancy muncor = PM sample filter mass uncorrected for buoyancy ρair = density of air in balance environment ρweight = density of calibration weight used to span balance ρmedia = density of PM sample filter pabs ⋅ M mix ρair = (8-9) R ⋅ Tamb where: pabs = absolute pressure in balance environment Mmix = molar mass of air in balance environment R = molar gas constant Tamb = absolute ambient temperature of balance environment
Instrument validation for test
Validation of proportional flow control for batch sampling and minimum dilution ratio for PM batch sampling
Proportionality criteria for CVS
Proportional flows
For any pair of flow-meters, the recorded sample and total flow rates or their 1 Hz means shall be used with the statistical calculations in Annex 4B, Appendix A.2, paragraph A.2.9. The standard error of the estimate, SEE, of the sample flow rate versus the total flow rate shall be determined. For each test interval, it shall be demonstrated that SEE was less than or equal to 3.5 per cent of the mean sample flow rate.
Annex 4B
Constant flows
For any pair of flow-meters, the recorded sample and total flow rates or their 1 Hz means shall be used to demonstrate that each flow rate was constant within ±2.5 per cent of its respective mean or target flow rate. The following options may be used instead of recording the respective flow rate of each type of meter:
(a) Critical-flow venturi option. For critical-flow venturis, the recorded venturi-inlet conditions or their 1 Hz means shall be used. It shall be demonstrated that the flow density at the venturi inlet was constant within ±2.5 per cent of the mean or target density over each test interval. For a CVS critical-flow venturi, this may be demonstrated by showing that the absolute temperature at the venturi inlet was constant within ±4 per cent of the mean or target absolute temperature over each test interval;
(b) Positive-displacement pump option. The recorded pump-inlet conditions or their 1 Hz means shall be used. It shall be demonstrated that the flow density at the pump inlet was constant within ±2.5 per cent of the mean or target density over each test interval. For a CVS pump, this may be demonstrated by showing that the absolute temperature at the pump inlet was constant within ±2 per cent of the mean or target absolute temperature over each test interval.
Demonstration of proportional sampling
For any proportional batch sample such as a bag or PM filter, it shall be demonstrated that proportional sampling was maintained using one of the following, noting that up to 5 per cent of the total number of data points may be omitted as outliers. Using good engineering judgment, it shall be demonstrated with an engineering analysis that the proportional-flow control system inherently ensures proportional sampling under all circumstances expected during testing. For example, CFVs may be used for both sample flow and total flow if it is demonstrated that they always have the same inlet pressures and temperatures and that they always operate under critical-flow conditions. Measured or calculated flows and/or tracer gas concentrations (e.g. CO2) shall be used to determine the minimum dilution ratio for PM batch sampling over the test interval.
Partial flow dilution system validation
For the control of a partial flow dilution system to extract a proportional raw exhaust sample, a fast system response is required; this is identified by the promptness of the partial flow dilution system. The transformation time for the system shall be determined by the procedure in paragraph 8.1.8.6. and the related the current measured conditions. If the combined transformation time of the exhaust flow measurement and the partial flow system is ≤ 0.3 s, online control shall be used. If the transformation time exceeds 0.3 s, look-ahead control based on a pre-recorded test run shall be used. In this case, the combined rise time shall be ≤ 1 s and the combined delay time ≤ 10 s. The total system response shall be designed as to ensure a representative sample of the particulates, qmp,i (sample flow of exhaust gas into partial flow dilution system), proportional to the exhaust
Annex 4B
mass flow. To determine the proportionality, a regression analysis of qmp,i versus qmew,i (exhaust gas mass flow rate on wet basis) shall be conducted on a minimum 5 Hz data acquisition rate, and the following criteria shall be met:
(a) The correlation coefficient r2 of the linear regression between qmp,i and qmew,i shall not be less than 0.95;
(b) The standard error of estimate of qmp,i on qmew,i shall not exceed 5 per cent of qmp maximum;
(c) qmp intercept of the regression line shall not exceed ±2 per cent of qmp maximum. Look-ahead control is required if the combined transformation times of the particulate system, t50,P and of the exhaust mass flow signal, t50,F are > 0.3 s. In this case, a pre-test shall be run and the exhaust mass flow signal of the pre-test be used for controlling the sample flow into the particulate system. A correct control of the partial dilution system is obtained, if the time trace of qmew,pre of the pre-test, which controls qmp, is shifted by a "look-ahead" time of t50,P + t50,F. For establishing the correlation between qmp,i and qmew,i the data taken during the actual test shall be used, with qmew,i time aligned by t50,F relative to qmp,i (no contribution from t50,P to the time alignment). The time shift between qmew and qmp is the difference between their transformation times that were determined in paragraph 8.1.8.6.3.2.
Gas analyser range validation, drift validation and drift correction
Range validation
If an analyser operated above 100 per cent of its range at any time during the test, the following steps shall be performed:
Batch sampling
For batch sampling, the sample shall be re-analysed using the lowest analyser range that results in a maximum instrument response below 100 per cent. The result shall be reported from the lowest range from which the analyser operates below 100 per cent of its range for the entire test.
Continuous sampling
For continuous sampling, the entire test shall be repeated using the next higher analyser range. If the analyser again operates above 100 per cent of its range, the test shall be repeated using the next higher range. The test shall be continued to be repeated until the analyser always operates at less than 100 per cent of its range for the entire test.
Drift validation and drift correction
If the drift is within ±1 per cent, the data can be either accepted without any correction or accepted after correction. If the drift is greater than ±1 per cent, two sets of brake specific emission results shall be calculated for each pollutant, or the test shall be voided. One set shall be calculated using data before drift correction and another set of data calculated after correcting all the data for drift according to Appendix 2 of Annexes A.7 or A.8. The comparison shall be made as a percentage of the uncorrected results. The difference between the uncorrected and the corrected brake-specific emission values shall be within ±4 per cent of the uncorrected brake-specific emission values. If not, the entire test is void.
Annex 4B
PM sampling media (e.g. filters) preconditioning and tare weighing
Before an emission test, the following steps shall be taken to prepare PM sample filter media and equipment for PM measurements:
Periodic verifications
It shall be made sure that the balance and PM-stabilization environments meet the periodic verifications in paragraph 8.1.12. The reference filter shall be weighed just before weighing test filters to establish an appropriate reference point (see section details of the procedure in paragraph 8.1.12.1.). The verification of the stability of the reference filters shall occur after the post-test stabilization period, immediately before the post-test weighing.
Visual Inspection
The unused sample filter media shall be visually inspected for defects, defective filters shall be discarded.
Grounding
Electrically grounded tweezers or a grounding strap shall be used to handle PM filters as described in paragraph 9.3.4.
Unused sample media
Unused sample media shall be placed in one or more containers that are open to the PM-stabilization environment. If filters are used, they may be placed in the bottom half of a filter cassette.
Stabilization
Sample media shall be stabilized in the PM-stabilization environment. An unused sample medium can be considered stabilized as long as it has been in the PM-stabilization environment for a minimum of 30 min, during which the PM-stabilization environment has been within the specifications of paragraph 9.3.4.
Weighing
The sample media shall be weighed automatically or manually, as follows:
(a) For automatic weighing, the automation system manufacturer's instructions shall be followed to prepare samples for weighing;
(b) For manual weighing, good engineering judgment shall be used;
(c) Optionally, substitution weighing is permitted (see paragraph 8.2.3.10.);
(d) Once a filter is weighed it shall be returned to the Petri dish and covered.
Buoyancy correction
The measured weight shall be corrected for buoyancy as described in paragraph 8.1.12.2.
Repetition
The filter mass measurements may be repeated to determine the average mass of the filter using good engineering judgement and to exclude outliers from the calculation of the average.
Annex 4B
Tare-weighing
Unused filters that have been tare-weighed shall be loaded into clean filter cassettes and the loaded cassettes shall be placed in a covered or sealed container before they are taken to the test cell for sampling.
Substitution weighing
Substitution weighing is an option and, if used, involves measurement of a reference weight before and after each weighing of a PM sampling medium (e.g. filter). While substitution weighing requires more measurements, it corrects for a balance's zero-drift and it relies on balance linearity only over a small range. This is most appropriate when quantifying total PM masses that are less than 0.1 per cent of the sample medium's mass. However, it may not be appropriate when total PM masses exceed 1 per cent of the sample medium's mass. If substitution weighing is used, it shall be used for both pre-test and post-test weighing. The same substitution weight shall be used for both pre-test and post-test weighing. The mass of the substitution weight shall be corrected for buoyancy if the density of the substitution weight is less than 2.0 g/cm3. The following steps are an example of substitution weighing:
(a) Electrically grounded tweezers or a grounding strap shall be used, as described in paragraph 9.3.4.6.;
(b) A static neutralizer shall be used as described in paragraph 9.3.4.6. to minimize static electric charge on any object before it is placed on the balance pan;
(c) A substitution weight shall be selected that meets the specifications for calibration weights in paragraph 9.5.2. The substitution weight shall also have the same density as the weight that is used to span the microbalance, and shall be similar in mass to an unused sample medium (e.g. filter). If filters are used, the weight's mass should be about (80 to
100) mg for typical 47 mm diameter filters;
(d) The stable balance reading shall be recorded and then the calibration weight shall be removed;
(e) An unused sampling medium (e.g. a new filter) shall be weighed, the stable balance reading recorded and the balance environment's dew point, ambient temperature, and atmospheric pressure recorded;
(f) The calibration weight shall be reweighed and the stable balance reading recorded;
(g) The arithmetic mean of the two calibration-weight readings that were recorded immediately before and after weighing the unused sample shall be calculated. That mean value shall be subtracted from the unused sample reading, then the true mass of the calibration weight as stated on the calibration-weight certificate shall be added. This result shall be recorded. This is the unused sample's tare weight without correcting for buoyancy;
(h) These substitution-weighing steps shall be repeated for the remainder of the unused sample media;
(i) The instructions given in paragraphs 8.2.3.7. through 8.2.3.9. of this section shall be followed once weighing is completed.
Annex 4B
PM sample post-conditioning and total weighing
Periodic verification
It shall be assured that the weighing and PM-stabilization environments have met the periodic verifications in paragraph 8.1.12.1. After testing is complete, the filters shall be returned to the weighing and PM-stabilization environment. The weighing and PM-stabilization environment shall meet the ambient conditions requirements in paragraph 9.3.4.4., otherwise the test filters shall be left covered until proper conditions have been met.
Removal from sealed containers
In the PM-stabilization environment, the PM samples shall be removed from the sealed containers. Filters may be removed from their cassettes before or after stabilization. When a filter is removed from a cassette, the top half of the cassette shall be separated from the bottom half using a cassette separator designed for this purpose.
Electrical grounding
To handle PM samples, electrically grounded tweezers or a grounding strap shall be used, as described in paragraph 9.3.4.5.
Visual inspection
The collected PM samples and the associated filter media shall be inspected visually. If the conditions of either the filter or the collected PM sample appear to have been compromised, or if the particulate matter contacts any surface other than the filter, the sample may not be used to determine particulate emissions. In the case of contact with another surface; the affected surface shall be cleaned before proceeding.
Stabilization of PM samples
To stabilize PM samples, they shall be placed in one or more containers that are open to the PM-stabilization environment, which is described in paragraph 9.3.4.3. A PM sample is stabilized as long as it has been in the PM- stabilization environment for one of the following durations, during which the stabilization environment has been within the specifications of paragraph 9.3.4.3.:
(a) If it is expected that a filter's total surface concentration of PM will be greater than 0.353 µg/mm2, assuming a 400 µg loading on a 38 mm diameter filter stain area, the filter shall be exposed to the stabilization environment for at least 60 minutes before weighing;
(b) If it is expected that a filter's total surface concentration of PM will be less than 0.353 µg/mm2, the filter shall be exposed to the stabilization environment for at least 30 minutes before weighing;
(c) If a filter's total surface concentration of PM to be expected during the test is unknown, the filter shall be exposed to the stabilization environment for at least 60 minutes before weighing.
Determination of post-test filter mass
The procedures in paragraph 8.2.3. shall be repeated (paragraphs 8.2.3.6. through 8.2.3.9.) to determine the post-test filter mass.
Annex 4B
Total mass
Each buoyancy-corrected filter tare mass shall be subtracted from its respective buoyancy-corrected post-test filter mass. The result is the total mass, mtotal, which shall be used in emission calculations in Annexes A.7 and A.8.
9.Measurement equipment
Engine dynamometer specification
Shaft work
An engine dynamometer shall be used that has adequate characteristics to perform the applicable duty cycle including the ability to meet appropriate cycle validation criteria. The following dynamometers may be used:
(a) Eddy-current or water-brake dynamometers;
(b) Alternating-current or direct-current motoring dynamometers;
(c) One or more dynamometers.
Transient cycle
Load cell or in-line torque meter may be used for torque measurements. When using a load cell, the torque signal shall be transferred to the engine axis and the inertia of the dynamometer shall be considered. The actual engine torque is the torque read on the load cell plus the moment of inertia of the brake multiplied by the angular acceleration. The control system has to perform such a calculation in real time.
Engine accessories
The work of engine accessories required to fuel, lubricate, or heat the engine, circulate liquid coolant to the engine, or to operate after-treatment devices shall be accounted for and they shall be installed in accordance with paragraph 6.3.
Dilution procedure (if applicable)
Diluent conditions and background concentrations
Gaseous constituents may be measured raw or dilute whereas PM measurement generally requires dilution. Dilution may be accomplished by a full flow or partial flow dilution system. When dilution is applied then the exhaust may be diluted with ambient air, synthetic air, or nitrogen. For gaseous emissions measurement the diluent shall be at least 15 °C. For PM sampling the temperature of the diluent is specified in paragraphs 9.2.2. for CVS and 9.2.3. for PFD with varying dilution ratio. The flow capacity of the dilution system shall be large enough to completely eliminate water condensation in the dilution and sampling systems. De-humidifying the dilution air before entering the dilution system is permitted, if the air humidity is high. The dilution tunnel walls may be heated or insulated as well as the bulk stream tubing downstream of the tunnel to prevent aqueous condensation. Before a diluent is mixed with exhaust, it may be preconditioned by increasing or decreasing its temperature or humidity. Constituents may be removed from the diluent to reduce their background concentrations. The following provisions apply to removing constituents or accounting for background concentrations:
Annex 4B
(a) Constituent concentrations in the diluent may be measured and compensated for background effects on test results. See Annexes A.7- A.8 for calculations that compensate for background concentrations;
(b) To account for background PM the following options are available:
(i) For removing background PM, the diluent shall be filtered with high-efficiency particulate air (HEPA) filters that have an initial minimum collection efficiency specification of 99.97 per cent (see paragraph 3.1. for procedures related to HEPA-filtration efficiencies);
(ii) For correcting for background PM without HEPA filtration, the background PM shall not contribute more than 50 per cent of the net PM collected on the sample filter;
(iii) Background correction of net PM with HEPA filtration is permitted without restriction.
Full flow system
Full-flow dilution; constant-volume sampling (CVS). The full flow of raw exhaust is diluted in a dilution tunnel. Constant flow may be maintained by maintaining the temperature and pressure at the flow-meter within the limits. For non constant flow the flow shall be measured directly to allow for proportional sampling. The system shall be designed as follows (see
(a) A tunnel with inside surfaces of stainless steel shall be used. The entire dilution tunnel shall be electrically grounded;
(b) The exhaust system backpressure shall not be artificially lowered by the dilution air inlet system. The static pressure at the location where raw exhaust is introduced into the tunnel shall be maintained within ±1.2 kPa of atmospheric pressure;
(c) To support mixing the raw exhaust shall be introduced into the tunnel by directing it downstream along the centreline of the tunnel. A fraction of dilution air maybe introduced radially from the tunnel's inner surface to minimize exhaust interaction with the tunnel walls;
(d) Diluent. For PM sampling the temperature of the diluents (ambient air, synthetic air, or nitrogen as quoted in paragraph 9.2.1.) shall be maintained between 293 and 325 K (20 to 52°C) in close proximity to the entrance into the dilution tunnel.
(e) The Reynolds number, Re, shall be at least 4000 for the diluted exhaust stream, where Re is based on the inside diameter of the dilution tunnel. Re is defined in Annexes A.7-A.8. Verification of adequate mixing shall be performed while traversing a sampling probe across the tunnel's diameter, vertically and horizontally. If the analyser response indicates any deviation exceeding ±2 per cent of the mean measured concentration, the CVS shall be operated at a higher flow rate or a mixing plate or orifice shall be installed to improve mixing;
(f) Flow measurement preconditioning. The diluted exhaust may be conditioned before measuring its flow rate, as long as this conditioning takes place downstream of heated HC or PM sample probes, as follows:
Annex 4B
(i) Flow straighteners, pulsation dampeners, or both of these maybe used;
(ii) A filter maybe used;
(iii) A heat exchanger maybe used to control the temperature upstream of any flow-meter but steps shall be taken to prevent aqueous condensation;
(g) Aqueous condensation. To ensure that a flow is measured that corresponds to a measured concentration, either aqueous condensation shall be prevented between the sample probe location and the flow- meter inlet in the dilution tunnel or aqueous condensation shall be allowed to occur and humidity at the flow-meter inlet measured. The dilution tunnel walls or bulk stream tubing downstream of the tunnel may be heated or insulated to prevent aqueous condensation. Aqueous condensation shall be prevented throughout the dilution tunnel. Certain exhaust components can be diluted or eliminated by the presence of moisture; For PM sampling, the already proportional flow coming from CVS goes through secondary dilution (one or more) to achieve the requested overall dilution ratio as shown in Figure 9.2 and mentioned in paragraph 9.2.3.2.;
(h) The minimum overall dilution ratio shall be within the range of 5:1 to 7:1 and at least 2:1 for the primary dilution stage based on the maximum engine exhaust flow rate during the test cycle or test interval;
(i) The overall residence time in the system shall be between 0.5 and 5 s, as measured from the point of diluent introduction to the filter holder(s);
(j) The residence time in the secondary dilution system, if present, shall be at least 0.5 s, as measured from the point of secondary diluent introduction to the filter holder(s). To determine the mass of the particulates, a particulate sampling system, a particulate sampling filter, a gravimetric balance, and a temperature and humidity controlled weighing chamber, are required.
Annex 4B
Examples of full-flow dilution sampling configurations
Partial flow dilution (PFD) system
Description of partial flow system
A schematic of a PFD system is shown in Figure 9.2. It is a general schematic showing principles of sample extraction, dilution and PM sampling. It is not meant to indicate that all the components described in the figure are necessary for other possible sampling systems that satisfy the intent of sample collection. Other configurations which do not match these schematics are allowed under the condition that they serve the same purpose of sample collection, dilution, and PM sampling. These need to satisfy other criteria such as in paragraphs 8.1.8.6. (periodic calibration) and 8.2.1.2. (validation) for varying dilution PFD, and paragraph 8.1.4.5. as well as Table 8.2 (linearity verification) and paragraph 8.1.8.5.7. (verification) for constant dilution PFD. As shown in Figure 9.2, the raw exhaust gas or the primary diluted flow is transferred from the exhaust pipe EP or from CVS respectively to the dilution tunnel DT through the sampling probe SP and the transfer line TL. The total flow through the tunnel is adjusted with a flow controller and the sampling pump P of the particulate sampling system (PSS). For proportional raw exhaust sampling, the dilution air flow is controlled by the flow controller FC1, which may use qmew (exhaust gas mass flow rate on wet basis) or qmaw (intake air mass flow rate on wet basis) and qmf (fuel mass flow rate) as command signals, for the desired exhaust split. The sample flow into the dilution tunnel DT is the difference of the total flow and the dilution air flow. The dilution air flow rate is measured with the flow measurement device
Annex 4B
FM1, the total flow rate with the flow measurement device of the particulate sampling system. The dilution ratio is calculated from these two flow rates. For sampling with a constant dilution ratio of raw or diluted exhaust versus exhaust flow (e.g.: secondary dilution for PM sampling), the dilution air flow rate is usually constant and controlled by the flow controller FC1 or dilution air pump.
Schematic of partial flow dilution system (total sampling type)
a = engine exhaust or primary diluted flow b = optional c = PM sampling
Components of Figure 9.2: DAF = Dilution air filter – The dilution air (ambient air, synthetic air, or nitrogen) shall be filtered with a high-efficiency PM air (HEPA) filter. DT = Dilution tunnel or secondary dilution system EP = Exhaust pipe or primary dilution system FC1 = Flow controller FH = Filter holder FM1 = Flow measurement device measuring the dilution air flow rate P = Sampling pump PSS = PM sampling system PTL = PM transfer line SP = Raw or dilute exhaust gas sampling probe TL = Transfer line
Annex 4B
Mass flow rates applicable only for proportional raw exhaust sampling PFD: qmew = Exhaust gas mass gas flow rate on wet basis qmaw = Intake air mass flow rate on wet basis qmf = Fuel mass flow rate
Dilution
The temperature of the diluents (ambient air, synthetic air, or nitrogen as quoted in paragraph 9.2.1.) shall be maintained between 293 and 325 K (20 to 52°C) in close proximity to the entrance into the dilution tunnel. De-humidifying the dilution air before entering the dilution system is permitted. The partial flow dilution system has to be designed to extract a proportional raw exhaust sample from the engine exhaust stream, thus responding to excursions in the exhaust stream flow rate, and introduce dilution air to this sample to achieve a temperature at the test filter as prescribed by paragraph 9.3.3.4.3. For this it is essential that the dilution ratio be determined such that the accuracy requirements of paragraph 8.1.8.6.1. are fulfilled. To ensure that a flow is measured that corresponds to a measured concentration, either aqueous condensation shall be prevented between the sample probe location and the flow-meter inlet in the dilution tunnel or aqueous condensation shall be allowed to occur and humidity at the flow-meter inlet measured. The PFD system may be heated or insulated to prevent aqueous condensation. Aqueous condensation shall be prevented throughout the dilution tunnel. The minimum dilution ratio shall be within the range of 5:1 to 7:1 based on the maximum engine exhaust flow rate during the test cycle or test interval. The residence time in the system shall be between 0.5 and 5 s, as measured from the point of diluent introduction to the filter holder(s). To determine the mass of the particulates, a particulate sampling system, a particulate sampling filter, a gravimetric balance, and a temperature and humidity controlled weighing chamber, are required.
Applicability
PFD may be used to extract a proportional raw exhaust sample for any batch or continuous PM and gaseous emission sampling over any transient duty cycle, any steady-state duty cycle or any ramped-modal duty cycle. The system may be used also for a previously diluted exhaust where, via a constant dilution-ratio, an already proportional flow is diluted (see Figure 9.2). This is the way of performing secondary dilution from a CVS tunnel to achieve the necessary overall dilution ratio for PM sampling.
Calibration
The calibration of the PFD to extract a proportional raw exhaust sample is considered in paragraph 8.1.8.6.
Annex 4B
Sampling procedures
9.3.1 General sampling requirements
Probe design and construction
A probe is the first fitting in a sampling system. It protrudes into a raw or diluted exhaust stream to extract a sample, such that it's inside and outside surfaces are in contact with the exhaust. A sample is transported out of a probe into a transfer line. Sample probes shall be made with inside surfaces of stainless steel or, for raw exhaust sampling, with any non-reactive material capable of withstanding raw exhaust temperatures. Sample probes shall be located where constituents are mixed to their mean sample concentration and where interference with other probes is minimized. It is recommended that all probes remain free from influences of boundary layers, wakes, and eddies – especially near the outlet of a raw-exhaust tailpipe where unintended dilution might occur. Purging or back- flushing of a probe shall not influence another probe during testing. A single probe to extract a sample of more than one constituent may be used as long as the probe meets all the specifications for each constituent.
Transfer lines
Transfer lines that transport an extracted sample from a probe to an analyser, storage medium, or dilution system shall be minimized in length by locating analysers, storage media, and dilution systems as close to the probes as practical. The number of bends in transfer lines shall be minimized and that the radius of any unavoidable bend shall be maximized.
Sampling methods
For continuous and batch sampling, introduced in paragraph 7.2., the following conditions apply:
(a) When extracting from a constant flow rate, the sample shall also be carried out at a constant flow rate;
(b) When extracting from a varying flow rate, the sample flow rate shall be varied in proportion to the varying flow rate;
(c) Proportional sampling shall be validated as described in paragraph 8.2.1.
Gas sampling
Sampling probes
Either single-port or multi-port probes are used for sampling gaseous emissions. The probes may be oriented in any direction relative to the raw or diluted exhaust flow. For some probes, the sample temperatures shall be controlled, as follows:
(a) For probes that extract NOx from diluted exhaust, the probe's wall temperature shall be controlled to prevent aqueous condensation;
(b) For probes that extract hydrocarbons from the diluted exhaust, a probe wall temperature is recommended to be controlled approximately 190 ºC to minimize contamination.
Annex 4B
Transfer lines
Transfer lines with inside surfaces of stainless steel, PTFE, VitonTM, or any other material that has better properties for emission sampling shall be used. A non-reactive material capable of withstanding exhaust temperatures shall be used. In-line filters may be used if the filter and its housing meet the same temperature requirements as the transfer lines, as follows:
(a) For NOx transfer lines upstream of either an NO2-to-NO converter that meets the specifications of paragraph 8.1.11.5. or a chiller that meets the specifications of paragraph 8.1.11.4. a sample temperature that prevents aqueous condensation shall be maintained;
(b) For THC transfer lines a wall temperature tolerance throughout the entire line of (191 ± 11) °C shall be maintained. If sampled from raw exhaust, an unheated, insulated transfer line may be connected directly to a probe. The length and insulation of the transfer line shall be designed to cool the highest expected raw exhaust temperature to no lower than 191 °C, as measured at the transfer line outlet. For dilute sampling a transition zone between the probe and transfer line of up to 0.92 m in length is allowed to transition the wall temperature to (191 ± 11) °C.
Sample-conditioning components
Sample dryers
Requirements
The instrument that is used for removing moisture shall meet the minimum requirements in the following paragraph. The moisture content of 0.8 volume per cent H2O is used in equation (A.8-14). For the highest expected water vapour concentration Hm, the water removal technique shall maintain CLD humidity at ≤ 5 g water/kg dry air (or about 0.8 volume per cent H2O), which is 100 per cent relative humidity at 3.9 °C and 101.3 kPa. This humidity specification is also equivalent to about 25 per cent relative humidity at 25 °C and 101.3 kPa. This may be demonstrated by measuring the temperature at the outlet of a thermal dehumidifier, or by measuring humidity at a point just upstream of the CLD.
Type of sample dryers allowed and procedure to estimate moisture content after the dryer Either type of sample dryer described in this paragraph to decrease the effects of water on gaseous emission measurements may be used.
(a) If an osmotic-membrane dryer upstream of any gaseous analyser or storage medium is used, it shall meet the temperature specifications in paragraph 9.3.2.2. The dew point, Tdew, and absolute pressure, ptotal, downstream of an osmotic-membrane dryer shall be monitored. The amount of water shall be calculated as specified in Annexes A.7-A.8 by using continuously recorded values of Tdew and ptotal or their peak values observed during a test or their alarm set points. Lacking a direct measurement, the nominal ptotal is given by the dryer's lowest absolute pressure expected during testing;
Annex 4B
(b) A thermal chiller upstream of a THC measurement system for compression-ignition engines may not be used. If a thermal chiller upstream of an NO2-to-NO converter or in a sampling system without an NO2-to-NO converter is used, the chiller shall meet the NO2 loss- performance check specified in paragraph 8.1.11.4. The dew point, Tdew, and absolute pressure, ptotal, downstream of a thermal chiller shall be monitored. The amount of water shall be calculated as specified in Annexes A.7-A.8 by using continuously recorded values of Tdew and ptotal or their peak values observed during a test or their alarm set points. Lacking a direct measurement, the nominal ptotal is given by the thermal chiller's lowest absolute pressure expected during testing. If it is valid to assume the degree of saturation in the thermal chiller, Tdew based on the known chiller efficiency and continuous monitoring of chiller temperature, Tchiller may be calculated. If values of Tchiller are not continuously recorded, its peak value observed during a test, or its alarm setpoint, may be used as a constant value to determine a constant amount of water according to Annexes A.7-A.8. If it is valid to assume that Tchiller is equal to Tdew, Tchiller may be used in lieu of Tdew according to Annexes A.7-A.8. If it is valid to assume a constant temperature offset between Tchiller and Tdew, due to a known and fixed amount of sample reheat between the chiller outlet and the temperature measurement location, this assumed temperature offset value may be factored in into emission calculations. The validity of any assumptions allowed by this paragraph shall be shown by engineering analysis or by data.
Sample pumps
Sample pumps upstream of an analyser or storage medium for any gas shall be used. Sample pumps with inside surfaces of stainless steel, PTFE, or any other material having better properties for emission sampling shall be used. For some sample pumps, temperatures shall be controlled, as follows:
(a) If a NOx sample pump upstream of either an NO2-to-NO converter that meets paragraph 8.1.11.5. or a chiller that meets paragraph 8.1.11.4. is used, it shall be heated to prevent aqueous condensation;
(b) If a THC sample pump upstream of a THC analyser or storage medium is used, its inner surfaces shall be heated to a tolerance of (191 ± 11) °C.
Sample storage media
In the case of bag sampling, gas volumes shall be stored in sufficiently clean containers that minimally off-gas or allow permeation of gases. Good engineering judgment shall be used to determine acceptable thresholds of storage media cleanliness and permeation. To clean a container, it may be repeatedly purged and evacuated and may be heated. A flexible container (such as a bag) within a temperature-controlled environment, or a temperature controlled rigid container that is initially evacuated or has a volume that can be displaced, such as a piston and cylinder arrangement, shall be used. Containers meeting the specifications in the following Table 9.1 shall be used.
Annex 4B
.1
Gaseous Batch Sampling Container Materials CO, CO2, O2, CH4, polyvinyl fluoride (PVF)2 for example TedlarTM, polyvinylidene fluoride2 C2H6, C3H8, NO, NO21 for example KynarTM, polytetrafluoroethylene3 for example TeflonTM, or stainless steel3 THC, NMHC polytetrafluoroethylene4 or stainless steel4 As long as aqueous condensation in storage container is prevented. Up to 40 °C. Up to 202 °C. At (191 ± 11) °C.
PM sampling
Sampling probes
PM probes with a single opening at the end shall be used. PM probes shall be oriented to face directly upstream. The PM probe may be shielded with a hat that conforms with the requirements in Figure 9.3. In this case the pre-classifier described in paragraph 9.3.3.3. shall not be used.
Scheme of a sampling probe with a hat-shaped pre-classifier
Transfer lines
Insulated or heated transfer lines or a heated enclosure are recommended to minimize temperature differences between transfer lines and exhaust constituents. Transfer lines that are inert with respect to PM and are electrically conductive on the inside surfaces shall be used. It is recommended using PM transfer lines made of stainless steel; any material other than stainless steel will be required to meet the same sampling performance as stainless steel. The inside surface of PM transfer lines shall be electrically grounded.
Pre-classifier
The use of a PM pre-classifier to remove large-diameter particles is permitted that is installed in the dilution system directly before the filter holder. Only one pre-classifier is permitted. If a hat shaped probe is used (see Figure 9.3), the use of a pre-classifier is prohibited.
Annex 4B
The PM pre-classifier may be either an inertial impactor or a cyclonic separator. It shall be constructed of stainless steel. The pre-classifier shall be rated to remove at least 50 per cent of PM at an aerodynamic diameter of 10 µm and no more than 1 per cent of PM at an aerodynamic diameter of 1 µm over the range of flow rates for which it is used. The pre-classifier outlet shall be configured with a means of bypassing any PM sample filter so that the pre- classifier flow can be stabilized before starting a test. PM sample filter shall be located within 75 cm downstream of the pre-classifier's exit.
Sample filter
The diluted exhaust shall be sampled by a filter that meets the requirements of paragraphs 9.3.3.4.1. to 9.3.3.4.4. during the test sequence.
Filter specification
All filter types shall have a 0.3 µm DOP (di-octylphthalate) collection efficiency of at least 99.7 per cent. The sample filter manufacturer's measurements reflected in their product ratings may be used to show this requirement. The filter material shall be either:
(a) Fluorocarbon (PTFE) coated glass fibre; or
(b) Fluorocarbon (PTFE) membrane. If the expected net PM mass on the filter exceeds 400 µg, a filter with a minimum initial collection efficiency of 98 per cent may be used.
Filter size
The nominal filter size shall be 46.50 mm ± 0.6 mm diameter.
Dilution and temperature control of PM samples
PM samples shall be diluted at least once upstream of transfer lines in case of a CVS system and downstream in case of PFD system (see paragraph 9.3.3.2. relating to transfer lines). Sample temperature is to be controlled to a (47 ± 5) °C tolerance, as measured anywhere within 200 mm upstream or 200 mm downstream of the PM storage media. The PM sample is intended to be heated or cooled primarily by dilution conditions as specified in sub- paragraph (a) of paragraph 9.2.1.
Filter face velocity
A filter face velocity shall be between 0.90 and 1.00 m/s with less than 5 per cent of the recorded flow values exceeding this range. If the total PM mass exceeds 400 µg, the filter face velocity may be reduced. The face velocity shall be measured as the volumetric flow rate of the sample at the pressure upstream of the filter and temperature of the filter face, divided by the filter's exposed area. The exhaust stack or CVS tunnel pressure shall be used for the upstream pressure if the pressure drop through the PM sampler up to the filter is less than 2 kPa. 9.3.3.4.5 Filter holder To minimize turbulent deposition and to deposit PM evenly on a filter, a 12.5° (from centre) divergent cone angle to transition from the transfer-line inside diameter to the exposed diameter of the filter face shall be used. Stainless steel for this transition shall be used.
Annex 4B
PM-stabilization and weighing environments for gravimetric analysis
Environment for gravimetric analysis
This section describes the two environments required to stabilize and weigh PM for gravimetric analysis: the PM stabilization environment, where filters are stored before weighing; and the weighing environment, where the balance is located. The two environments may share a common space. Both the stabilization and the weighing environments shall be kept free of ambient contaminants, such as dust, aerosols, or semi-volatile material that could contaminate PM samples.
Cleanliness
The cleanliness of the PM-stabilization environment using reference filters shall be verified, as described in paragraph 8.1.12.1.4.
Temperature of the chamber
The temperature of the chamber (or room) in which the particulate filters are conditioned and weighed shall be maintained to within 22 °C ± 1 °C during all filter conditioning and weighing. The humidity shall be maintained to a dew point of 9.5 °C ± 1 °C and a relative humidity of 45 per cent ± 8 per cent. If the stabilization and weighing environments are separate, the stabilization environment shall be maintained at a tolerance of 22 °C ± 3 °C.
Verification of ambient conditions
When using measurement instruments that meet the specifications in paragraph 9.4 the following ambient conditions shall be verified:
(a) Dew point and ambient temperature shall be recorded. These values shall be used to determine if the stabilization and weighing environments have remained within the tolerances specified in paragraph 9.3.4.3. of this section for at least 60 min before weighing filters;
(b) Atmospheric pressure shall be continuously recorded within the weighing environment. An acceptable alternative is to use a barometer that measures atmospheric pressure outside the weighing environment, as long as it can be ensured that the atmospheric pressure at the balance is always at the balance within ±100 Pa of the shared atmospheric pressure. A means to record the most recent atmospheric pressure shall be provided when each PM sample is weighed. This value shall be used to calculate the PM buoyancy correction in paragraph 8.1.12.2.
Installation of balance
The balance shall be installed as follows:
(a) Installed on a vibration-isolation platform to isolate it from external noise and vibration;
(b) Shielded from convective airflow with a static-dissipating draft shield that is electrically grounded.
Annex 4B
Static electric charge
Static electric charge shall be minimized in the balance environment, as follows:
(a) The balance is electrically grounded;
(b) Stainless steel tweezers shall be used if PM samples shall be handled manually;
(c) Tweezers shall be grounded with a grounding strap, or a grounding strap shall be provided for the operator such that the grounding strap shares a common ground with the balance;
(d) A static-electricity neutralizer shall be provided that is electrically grounded in common with the balance to remove static charge from PM samples.
Measurement instruments
Introduction
Scope
This paragraph specifies measurement instruments and associated system requirements related to emission testing. This includes laboratory instruments for measuring engine parameters, ambient conditions, flow-related parameters, and emission concentrations (raw or diluted).
Instrument types
Any instrument mentioned in this annex shall be used as described in the annex itself (see Table 8.2 for measurement quantities provided by these instruments). Whenever an instrument mentioned in this annex is used in a way that is not specified, or another instrument is used in its place, the requirements for equivalency provisions shall apply as specified in paragraph 5.1.3. Where more than one instrument for a particular measurement is specified, one of them will be identified by the Type Approval Authority upon application as the reference for showing that an alternative procedure is equivalent to the specified procedure.
Redundant systems
Data from multiple instruments to calculate test results for a single test may be used for all measurement instruments described in this paragraph, with prior approval of the Type Approval Authority. Results from all measurements shall be recorded and the raw data shall be retained, as described in paragraph 5.3 of this annex. This requirement applies whether or not the measurements are actually used in the calculations.
Data recording and control
The test system shall be able to update data, record data and control systems related to operator demand, the dynamometer, sampling equipment, and measurement instruments. Data acquisition and control systems shall be used that can record at the specified minimum frequencies, as shown in Table 9.2 (this table does not apply to discrete mode testing).
Annex 4B
Data recording and control minimum frequencies
Applicable test Minimum protocol command and Minimum recording section Measured values control frequency frequency
Speed and torque during an engine step-map 1 Hz 1 mean value per step
Speed and torque during an engine sweep-map 5 Hz 1 Hz means
Transient duty cycle reference and feedback speeds 5 Hz 1 Hz means and torques
Steady-state and ramped-modal duty cycle reference 1 Hz 1 Hz and feedback speeds and torques
Continuous concentrations of raw analysers N/A 1 Hz
Continuous concentrations of dilute analysers N/A 1 Hz
Batch concentrations of raw or dilute analysers N/A 1 mean value per test interval
Diluted exhaust flow rate from a CVS with a heat N/A 1 Hz
exchanger upstream of the flow measurement
Diluted exhaust flow rate from a CVS without a heat 5 Hz 1 Hz means
exchanger upstream of the flow measurement
Intake-air or exhaust flow rate (for raw transient N/A 1 Hz means
measurement)
Dilution air if actively controlled 5 Hz 1 Hz means
Sample flow from a CVS with a heat exchanger 1 Hz 1 Hz
Sample flow from a CVS without a heat exchanger 5 Hz 1 Hz mean
Performance specifications for measurement instruments
Overview
The test system as a whole shall meet all the applicable calibrations, verifications, and test-validation criteria specified in paragraph 8.1., including the requirements of the linearity check of paragraphs 8.1.4. and 8.2. Instruments shall meet the specifications in Table 9.2 for all ranges to be used for testing. Furthermore, any documentation received from instrument manufacturers showing that instruments meet the specifications in Table 9.2 shall be kept.
Annex 4B
Component requirements
pressure, sensors of temperature and dew point, and other instruments. The overall system for measuring the given physical and/or chemical quantity shall meet the linearity verification in paragraph 8.1.4. For gaseous emissions measurements, analysers may be used, that have compensation algorithms that are functions of other measured gaseous components, and of the fuel properties for the specific engine test. Any compensation algorithm shall only provide offset compensation without affecting any gain (that is no bias). Recommended performance specifications for measurement instruments
Measured Complete Recording quantity system update a a Measurement instrument symbol rise time frequency Accuracy Repeatability )
Engine speed transducer n 1s 1 Hz means 2.0 % of pt. or 1.0 % of pt. or 0.5 % of max 0.25 % of max
Engine torque transducer T 1s 1 Hz means 2.0 % of pt. or 1.0 % of pt. or 1.0 % of max 0.5 % of max
Fuel flow-meter 5s 1 Hz 2.0 % of pt. or 1.0 % of pt. or (Fuel totalizer) (N/A) (N/A) 1.5 % of max 0.75 % of max
Total diluted exhaust meter (CVS) 1s 1 Hz means 2.0 % of pt. or 1.0 % of pt. or (With heat exchanger before (5 s) (1 Hz) 1.5 % of max 0.75 % of max meter)
Dilution air, inlet air, exhaust, and 1s 1 Hz means 2.5 % of pt. or 1.25 % of pt. sample flow-meters of 5 Hz 1.5 % of max or 0.75 % of samples max
Continuous gas analyser raw x 2.5 s 2 Hz 2.0 % of pt. or 1.0 % of pt. or 2.0 % of meas. 1.0 % of meas.
Continuous gas analyser dilute x 5s 1 Hz 2.0 % of pt. or 1.0 % of pt. or 2.0 % of meas. 1.0 % of meas.
Continuous gas analyser x 5s 1 Hz 2.0 % of pt. or 1.0 % of pt. or 2.0 % of meas. 1.0 % of meas.
Batch gas analyser x N/A N/A 2.0 % of pt. or 1.0 % of pt. or 2.0 % of meas. 1.0 % of meas.
Gravimetric PM balance mPM N/A N/A See 9.4.11. 0.5 µg
Inertial PM balance mPM 5s 1 Hz 2.0 % of pt. or 1.0 % of pt. or 2.0 % of meas. 1.0 % of meas. a Accuracy and repeatability are all determined with the same collected data, as described in 9.4.3., and based on absolute values. "pt." refers to the overall mean value expected at the emission limit; "max." refers to the peak value expected at the emission limit over the duty cycle , not the maximum of the instrument's range; "meas." refers to the actual mean measured over the duty cycle.
Annex 4B
Measurement of engine parameters & ambient conditions
Speed and torque sensors
Application
Measurement instruments for work inputs and outputs during engine operation shall meet the specifications in this paragraph. Sensors, transducers, and meters meeting the specifications in Table 9.3 are recommended. Overall systems for measuring work inputs and outputs shall meet the linearity verifications in paragraph 8.1.4.
Shaft work
Work and power shall be calculated from outputs of speed and torque transducers according to paragraph 9.4.4.1. Overall systems for measuring speed and torque shall meet the calibration and verifications in paragraphs 8.1.7. and 8.1.4. Torque induced by the inertia of accelerating and decelerating components connected to the flywheel, such as the drive shaft and dynamometer rotor, shall be compensated for as needed, based on good engineering judgment.
Pressure transducers, temperature sensors, and dew point sensors
Overall systems for measuring pressure, temperature, and dew point shall meet the calibration in paragraph 8.1.7. Pressure transducers shall be located in a temperature-controlled environment, or they shall compensate for temperature changes over their expected operating range. Transducer materials shall be compatible with the fluid being measured.
Flow-related measurements
For any type of flow-meter (of fuel, intake-air, raw exhaust, diluted exhaust, sample), the flow shall be conditioned as needed to prevent wakes, eddies, circulating flows, or flow pulsations from affecting the accuracy or repeatability of the meter. For some meters, this may be accomplished by using a sufficient length of straight tubing (such as a length equal to at least 10 pipe diameters) or by using specially designed tubing bends, straightening fins, orifice plates (or pneumatic pulsation dampeners for the fuel flow-meter) to establish a steady and predictable velocity profile upstream of the meter.
Fuel flow-meter
Overall system for measuring fuel flow shall meet the calibration in paragraph 8.1.8.1. In any fuel flow measurement it shall be accounted for any fuel that bypasses the engine or returns from the engine to the fuel storage tank.
Intake-air flow-meter
Overall system for measuring intake-air flow shall meet the calibration in paragraph 8.1.8.2.
Raw exhaust flow-meter
Component requirements
The overall system for measuring raw exhaust flow shall meet the linearity requirements in paragraph 8.1.4. Any raw-exhaust meter shall be designed to appropriately compensate for changes in the raw exhaust's thermodynamic, fluid, and compositional states.
Annex 4B
Flow-meter response time
For the purpose of controlling of a partial flow dilution system to extract a proportional raw exhaust sample, a flow-meter response time faster than indicated in Table 9.3 is required. For partial flow dilution systems with online control, the flow-meter response time shall meet the specifications of paragraph 8.2.1.2.
Exhaust cooling
Exhaust cooling upstream of the flow-meter is permitted with the following restrictions:
(a) PM shall not be sampled downstream of the cooling;
(b) If cooling causes exhaust temperatures above 202 °C to decrease to below 180 °C, NMHC shall not be sampled downstream of the cooling;
(c) If cooling causes aqueous condensation, NOx shall not be sampled downstream of the cooling unless the cooler meets the performance verification in paragraph 8.1.11.4.;
(d) If cooling causes aqueous condensation before the flow reaches a flow- meter, Tdew and pressure ptotal shall be measured at the flow-meter inlet. These values shall be used in emission calculations according to Annexes A.7-A.8.
Dilution air and diluted exhaust flow-meters
Application
Instantaneous diluted exhaust flow rates or total diluted exhaust flow over a test interval shall be determined by using a diluted exhaust flow-meter. Raw exhaust flow rates or total raw exhaust flow over a test interval may be calculated from the difference between a diluted exhaust flow-meter and a dilution air meter.
Component requirements
The overall system for measuring diluted exhaust flow shall meet the calibration and verifications in paragraphs 8.1.8.4. and 8.1.8.5. The following meters may be used:
(a) For constant-volume sampling (CVS) of the total flow of diluted exhaust, a critical-flow venturi (CFV) or multiple critical-flow venturis arranged in parallel, a positive-displacement pump (PDP), a subsonic venturi (SSV), or an ultrasonic flow-meter (UFM) may be used. Combined with an upstream heat exchanger, either a CFV or a PDP will also function as a passive flow controller by keeping the diluted exhaust temperature constant in a CVS system;
(b) For the Partial Flow Dilution (PFD) system the combination of any flow-meter with any active flow control system to maintain proportional sampling of exhaust constituents may be used. The total flow of diluted exhaust, or one or more sample flows, or a combination of these flow controls may be controlled to maintain proportional sampling.
Annex 4B
For any other dilution system, a laminar flow element, an ultrasonic flow- meter, a subsonic venturi, a critical-flow venturi or multiple critical-flow venturis arranged in parallel, a positive-displacement meter, a thermal-mass meter, an averaging Pitot tube, or a hot-wire anemometer may be used.
Exhaust cooling
Diluted exhaust upstream of a dilute flow-meter may be cooled, as long as all the following provisions are observed:
(a) PM shall not be sampled downstream of the cooling;
(b) If cooling causes exhaust temperatures above 202 °C to decrease to below 180 °C, NMHC shall not be sampled downstream of the cooling;
(c) If cooling causes aqueous condensation, NOx shall not be sampled downstream of the cooling unless the cooler meets the performance verification in paragraph 8.1.11.4.;
(d) If cooling causes aqueous condensation before the flow reaches a flow- meter, dew point, Tdew and pressure ptotal shall be measured at the flow- meter inlet. These values shall be used in emission calculations according Annexes A.7-A.8.
Sample flow-meter for batch sampling
A sample flow-meter shall be used to determine sample flow rates or total flow sampled into a batch sampling system over a test interval. The difference between two flow-meters may be used to calculate sample flow into a dilution tunnel e.g. for partial flow dilution PM measurement and secondary dilution flow PM measurement. Specifications for differential flow measurement to extract a proportional raw exhaust sample is given in paragraph 8.1.8.6.1. and the calibration of differential flow measurement is given in paragraph 8.1.8.6.2. Overall system for the sample flow-meter shall meet the calibration in paragraph 8.1.8.
Gas divider
A gas divider may be used to blend calibration gases. A gas divider shall be used that blends gases to the specifications of paragraph 9.5.1. and to the concentrations expected during testing. Critical-flow gas dividers, capillary-tube gas dividers, or thermal-mass-meter gas dividers may be used. Viscosity corrections shall be applied as necessary (if not done by gas divider internal software) to appropriately ensure correct gas division. The gas- divider system shall meet the linearity verification in paragraph 8.1.4.5. Optionally, the blending device may be checked with an instrument which by nature is linear, e.g. using NO gas with a CLD. The span value of the instrument shall be adjusted with the span gas directly connected to the instrument. The gas divider shall be checked at the settings used and the nominal value shall be compared to the measured concentration of the instrument.
CO and CO2 measurements
A Non-dispersive infrared (NDIR) analyser shall be used to measure CO and CO2 concentrations in raw or diluted exhaust for either batch or continuous sampling.
Annex 4B
The NDIR-based system shall meet the calibration and verifications in paragraph 8.1.8.1.
Hydrocarbon measurements
Flame-ionization detector
Application
A heated flame-ionization detector (FID) analyser shall be used to measure hydrocarbon concentrations in raw or diluted exhaust for either batch or continuous sampling. Hydrocarbon concentrations shall be determined on a carbon number basis of one, C1. Methane and non-methane hydrocarbon values shall be determined as described in paragraph 9.4.7.1.4. Heated FID analysers shall maintain all surfaces that are exposed to emissions at a temperature of 191 ± 11 °C.
Component requirements
The FID-based system for measuring THC or CH4 shall meet all of the verifications for hydrocarbon measurement in paragraph 8.1.10.
FID fuel and burner air
FID fuel and burner air shall meet the specifications of paragraph 9.5.1. The FID fuel and burner air shall not mix before entering the FID analyser to ensure that the FID analyser operates with a diffusion flame and not a premixed flame.
Methane
FID analysers measure total hydrocarbons (THC). To determine non-methane hydrocarbons (NMHC), methane, CH4, shall be quantified either with a non- methane cutter and a FID analyser as described in paragraph 9.4.7.2., or with a gas chromatograph as described in paragraph 9.4.7.3. For a FID analyser used to determine NMHC, its response factor to CH4, RFCH4, shall be determined as described in paragraph 8.1.10.1. NMHC-related calculations are described in Annexes A.7-A.8.
Assumption on methane
Instead of measuring methane, it is allowed to assume that 2 per cent of measured total hydrocarbons is methane, as described in Annexes A.7-A.8.
Non-methane cutter
Application
A non-methane cutter may be used to measure CH4 with a FID analyser. A non-methane cutter oxidizes all non-methane hydrocarbons to CO2 and H2O. A non-methane cutter may be used for raw or diluted exhaust for batch or continuous sampling.
System performance
Non-methane-cutter performance shall be determined as described in paragraph 8.1.10.3. and the results shall be used to calculate NMHC emission in A.7 and A.8.
Annex 4B
Configuration
The non-methane cutter shall be configured with a bypass line for the verification described in paragraph 8.1.10.3.
Optimization
A non-methane cutter may be optimised to maximize the penetration of CH4 and the oxidation of all other hydrocarbons. A sample may be humidified and a sample may be diluted with purified air or oxygen (O2) upstream of non- methane cutter to optimize its performance. Any sample humidification and dilution shall be accounted for in emission calculations.
Gas chromatograph
Application: A gas chromatograph may be used to measure CH4 concentrations of diluted exhaust for batch sampling. While also a non-methane cutter may be used to measure CH4, as described in paragraph 9.4.7.2. a reference procedure based on a gas chromatograph shall be used for comparison with any proposed alternate measurement procedure under paragraph 5.1.3.
NOx measurements
Two measurement instruments are specified for NOx measurement and either instrument may be used provided it meets the criteria specified in paragraph 9.4.8.1. or 9.4.8.2., respectively. The chemiluminescent detector shall be used as the reference procedure for comparison with any proposed alternate measurement procedure under paragraph 5.1.3. of this annex.
Chemiluminescent detector
Application
A chemiluminescent detector (CLD) coupled with an NO2-to-NO converter is used to measure NOx concentration in raw or diluted exhaust for batch or continuous sampling.
Component requirements
The CLD-based system shall meet the quench verification in paragraph 8.1.11.1. A heated or unheated CLD may be used, and a CLD that operates at atmospheric pressure or under a vacuum may be used.
NO2-to-NO converter
An internal or external NO2-to-NO converter that meets the verification in paragraph 8.1.11.5. shall be placed upstream of the CLD, while the converter shall be configured with a bypass to facilitate this verification.
Humidity effects
All CLD temperatures shall be maintained to prevent aqueous condensation. To remove humidity from a sample upstream of a CLD, one of the following configurations shall be used:
(a) A CLD connected downstream of any dryer or chiller that is downstream of an NO2-to-NO converter that meets the verification in paragraph 8.1.11.5.;
(b) A CLD connected downstream of any dryer or thermal chiller that meets the verification in paragraph 8.1.11.4.
Annex 4B
Response time
A heated CLD may be used to improve CLD response time.
Non-dispersive ultraviolet analyser
Application
A non-dispersive ultraviolet (NDUV) analyser is used to measure NOx concentration in raw or diluted exhaust for batch or continuous sampling.
Component requirements
The NDUV-based system shall meet the verifications in paragraph 8.1.11.3.
NO2-to-NO converter
If the NDUV analyser measures only NO, an internal or external NO2-to-NO converter that meets the verification in paragraph 8.1.11.5. shall be placed upstream of the NDUV analyser. The converter shall be configured with a bypass to facilitate this verification.
Humidity effects
The NDUV temperature shall be maintained to prevent aqueous condensation, unless one of the following configurations is used:
(a) An NDUV shall be connected downstream of any dryer or chiller that is downstream of an NO2-to-NO converter that meets the verification in paragraph 8.1.11.5;
(b) An NDUV shall be connected downstream of any dryer or thermal chiller that meets the verification in paragraph 8.1.11.4.
O2 measurements
A paramagnetic detection (PMD) or magneto pneumatic detection (MPD) analyser shall be used to measure O2 concentration in raw or diluted exhaust for batch or continuous sampling.
Air-to-fuel ratio measurements
A Zirconia (ZrO2) analyser may be used to measure air-to-fuel ratio in raw exhaust for continuous sampling. O2 measurements with intake air or fuel flow measurements may be used to calculate exhaust flow rate according to Annexes A.7-A.8.
PM measurements with gravimetric balance
A balance shall be used to weigh net PM collected on sample filter media. The minimum requirement on the balance resolution shall be equal or lower than the repeatability of 0.5 microgram recommended in Table 9.3. If the balance uses internal calibration weights for routine spanning and linearity verifications, the calibration weights shall meet the specifications in paragraph 9.5.2. The balance shall be configured for optimum settling time and stability at its location.
Annex 4B
Analytical gases and mass standards
Analytical gases
Analytical gases shall meet the accuracy and purity specifications of this section.
Gas specifications
The following gas specifications shall be considered:
(a) Purified gases shall be used to zero measurement instruments and to blend with calibration gases. Gases with contamination no higher than the highest of the following values in the gas cylinder or at the outlet of a zero-gas generator shall be used:
(i) 2 per cent contamination, measured relative to the mean concentration expected at the standard. For example, if a CO concentration of 100.0 µmol/mol is expected, then it would be allowed to use a zero gas with CO contamination less than or equal to 2.000 µmol/mol;
(ii) Contamination as specified in Table 9.4, applicable for raw or dilute measurements;
(iii) Contamination as specified in Table 9.5, applicable for raw measurements.
Contamination limits, applicable for raw or dilute measurements [µmol/mol = ppm (3.2.)]
a a Constituent Purified Synthetic Air Purified N2
THC (C1 equivalent) ≤ 0.05 µmol/mol ≤ 0.05 µmol/mol
CO ≤ 1 µmol/mol ≤ 1 µmol/mol
CO2 ≤ 10 µmol/mol ≤ 10 µmol/mol
O2 0.205 to 0.215 mol/mol ≤ 2 µmol/mol
NOx ≤ 0.02 µmol/mol ≤ 0.02 µmol/mol
a It is not required that these levels of purity are international and/or national recognized standards- traceable.
Annex 4B
Contamination limits, applicable for raw measurements [µmol/mol = ppm (3.2.)]
a a Constituent Purified Synthetic Air Purified N2
THC (C1 equivalent) ≤ 1 µmol/mol ≤ 1 µmol/mol
CO ≤ 1 µmol/mol ≤ 1 µmol/mol
CO2 ≤ 400 µmol/mol ≤ 400 µmol/mol
O2 0.18 to 0.21 mol/mol -
NOx ≤ 0.1 µmol/mol ≤ 0.1 µmol/mol
a It is not required that these levels of purity are international and/or national recognized standards- traceable.
(b) The following gases shall be used with a FID analyser:
(i) FID fuel shall be used with an H2 concentration of (0.39 to 0.41) mol/mol, balance He. The mixture shall not contain more than 0.05 µmol/mol THC;
(ii) FID burner air shall be used that meets the specifications of purified air in paragraph (a) of this paragraph;
(iii) FID zero gas. Flame-ionization detectors shall be zeroed with purified gas that meets the specifications in paragraph (a) of this paragraph, except that the purified gas O2 concentration may be any value;
(iv) FID propane span gas. The THC FID shall be spanned and calibrated with span concentrations of propane, C3H8. It shall be calibrated on a carbon number basis of one (C1);
(v) FID methane span gas. If a CH4 FID is always spanned and calibrated with a non-methane cutter, then the FID shall be spanned and calibrated with span concentrations of methane, CH4. It shall be calibrated on a carbon number basis of one (C1);
(c) The following gas mixtures shall be used, with gases traceable within ±1.0 per cent of the international and/or national recognized standards true value or of other gas standards that are approved:
(i) CH4, balance purified synthetic air and/or N2 (as applicable);
(ii) C2H6, balance purified synthetic air and/or N2 (as applicable);
(iii) C3H8, balance purified synthetic air and/or N2 (as applicable);
(iv) CO, balance purified N2;
(v) CO2, balance purified N2;
(vi) NO, balance purified N2;
Annex 4B
(vii) NO2, balance purified synthetic air;
(viii) O2, balance purified N2;
(ix) C3H8, CO, CO2, NO, balance purified N2;
(x) C3H8, CH4, CO, CO2, NO, balance purified N2.
(d) Gases for species other than those listed in sub-paragraph (c) of this paragraph may be used (such as methanol in air, which may be used to determine response factors), as long as they are traceable to within ±3.0 per cent of the international and/or national recognized standards true value, and meet the stability requirements of paragraph 9.5.1.2.;
(e) Own calibration gases may be generated using a precision blending device, such as a gas divider, to dilute gases with purified N2 or purified synthetic air. If the gas dividers meet the specifications in paragraph 9.4.5.6., and the gases being blended meet the requirements of sub-paragraphs (a) and (c) of this paragraph, the resulting blends are considered to meet the requirements of this paragraph 9.5.1.1.
Concentration and expiration date
The concentration of any calibration gas standard and its expiration date specified by the gas supplier shall be recorded.
(a) No calibration gas standard may be used after its expiration date, except as allowed by sub-paragraph (b) of this paragraph.
(b) Calibration gases may be relabelled and used after their expiration date if it is approved in advance by Type Approval Authority.
Gas transfer
Gases shall be transferred from their source to analysers using components that are dedicated to controlling and transferring only those gases. The shelf life of all calibration gases shall be respected. The expiration date of the calibration gases stated by the manufacturer shall be recorded.
Mass standards
PM balance calibration weights that are certified as international and/or national recognized standards-traceable within 0.1 per cent uncertainty shall be used. Calibration weights may be certified by any calibration lab that maintains international and/or national recognized standards-traceability. It shall be made sure that the lowest calibration weight has no greater than ten times the mass of an unused PM-sample medium. The calibration report shall also state the density of the weights.
Annex 4B - Appendix A.1
Annex 4B - Appendix A.1
(Reserved)
Annex 4B - Appendix A.2
Annex 4B - Appendix A.2
Statistics A.2.1. Arithmetic mean The arithmetic mean, y , shall be calculated as follows: N
∑y i y = i =1 (A.2-1) N A.2.2. Standard deviation The standard deviation for a non-biased (e.g., N–1) sample, σ, shall be calculated as follows: N
∑( y − y ) i σy = i =1 (A.2-2) ( N − 1) A.2.3. Root mean square The root mean square, rmsy, shall be calculated as follows:
1 N 2 rms y = ∑ yi N i =1 (A.2-3)
A.2.4. t-test It shall be determined if the data passes a t-test by using the following equations and tables:
(a) For an unpaired t-test, the t statistic and its number of degrees of freedom, v, shall be calculated as follows:
yref − y t= (A.2-4) σ ref σ y2 + N ref N ⎛ σ ref σ y2 ⎞ ⎜⎜ + ⎟ ⎝ N ref N ⎟⎠ ν= (A.2-5) (σ ref2 Nref ) + (σ y2 N ) 2 2
N ref − 1 N −1
Annex 4B - Appendix A.2
(b) For a paired t-test, the t statistic and its number of degrees of freedom, v, shall be calculated as follows, noting that the εi are the errors (e.g., differences) between each pair of yrefi and yi:
ε ⋅ N ν = N −1 (A.2-6) t= σε
(c) Table A.2.1 of this paragraph shall be used to compare t to the tcrit values tabulated versus the number of degrees of freedom. If t is less than tcrit, then t passes the t-test. Table A.2.1 Critical t values versus number of degrees of freedom, ν
ν Confidence
90 per cent 95 per cent
1 6.314 12.706
2 2.920 4.303
3 2.353 3.182
4 2.132 2.776
5 2.015 2.571
6 1.943 2.447
7 1.895 2.365
8 1.860 2.306
9 1.833 2.262
10 1.812 2.228
11 1.796 2.201
12 1.782 2.179
13 1.771 2.160
14 1.761 2.145
15 1.753 2.131
16 1.746 2.120
18 1.734 2.101
Annex 4B - Appendix A.2
ν Confidence
90 per cent 95 per cent
20 1.725 2.086
22 1.717 2.074
24 1.711 2.064
26 1.706 2.056
28 1.701 2.048
30 1.697 2.042
35 1.690 2.030
40 1.684 2.021
50 1.676 2.009
70 1.667 1.994
100 1.660 1.984
1000+ 1.645 1.960
Linear interpolation shall be used to establish values not shown here. A.2.5. F-test The F statistic shall be calculated as follows:
σ y2 Fy = (A.2-7) σ ref
(a) For a 90 per cent confidence F-test, Table 2 of this paragraph is used to compare F to the Fcrit90 values tabulated versus (N−1) and (Nref−1). If F is less than Fcrit90, then F passes the F-test at 90 per cent confidence;
(b) For a 95 per cent confidence F-test, Table 3 of this paragraph is used to compare F to the Fcrit95 values tabulated versus (N−1) and (Nref−1). If F is less than Fcrit95, then F passes the F-test at 95 per cent confidence.
Annex 4B - Appendix A.2 Table A.2.2 Critical F values, Fcrit90, versus N-1 and Nref -1 at 90 per cent confidence
N-1 1 2 3 4 5 6 7 8 9 10 12 15 20 24 30 40 60 120 1000+ Nref-1 1 39.86 49.50 53.59 55.83 57.24 58.20 58.90 59.43 59.85 60.19 60.70 61.22 61.74 62.00 62.26 62.52 62.79 63.06 63.32 2 8.526 9.000 9.162 9.243 9.293 9.326 9.349 9.367 9.381 9.392 9.408 9.425 9.441 9.450 9.458 9.466 9.475 9.483 9.491 3 5.538 5.462 5.391 5.343 5.309 5.285 5.266 5.252 5.240 5.230 5.216 5.200 5.184 5.176 5.168 5.160 5.151 5.143 5.134 4 4.545 4.325 4.191 4.107 4.051 4.010 3.979 3.955 3.936 3.920 3.896 3.870 3.844 3.831 3.817 3.804 3.790 3.775 3.761 5 4.060 3.780 3.619 3.520 3.453 3.405 3.368 3.339 3.316 3.297 3.268 3.238 3.207 3.191 3.174 3.157 3.140 3.123 3.105 6 3.776 3.463 3.289 3.181 3.108 3.055 3.014 2.983 2.958 2.937 2.905 2.871 2.836 2.818 2.800 2.781 2.762 2.742 2.722 7 3.589 3.257 3.074 2.961 2.883 2.827 2.785 2.752 2.725 2.703 2.668 2.632 2.595 2.575 2.555 2.535 2.514 2.493 2.471 8 3.458 3.113 2.924 2.806 2.726 2.668 2.624 2.589 2.561 2.538 2.502 2.464 2.425 2.404 2.383 2.361 2.339 2.316 2.293 9 3.360 3.006 2.813 2.693 2.611 2.551 2.505 2.469 2.440 2.416 2.379 2.340 2.298 2.277 2.255 2.232 2.208 2.184 2.159 10 3.285 2.924 2.728 2.605 2.522 2.461 2.414 2.377 2.347 2.323 2.284 2.244 2.201 2.178 2.155 2.132 2.107 2.082 2.055 11 3.225 2.860 2.660 2.536 2.451 2.389 2.342 2.304 2.274 2.248 2.209 2.167 2.123 2.100 2.076 2.052 2.026 2.000 1.972 12 3.177 2.807 2.606 2.480 2.394 2.331 2.283 2.245 2.214 2.188 2.147 2.105 2.060 2.036 2.011 1.986 1.960 1.932 1.904 13 3.136 2.763 2.560 2.434 2.347 2.283 2.234 2.195 2.164 2.138 2.097 2.053 2.007 1.983 1.958 1.931 1.904 1.876 1.846 14 3.102 2.726 2.522 2.395 2.307 2.243 2.193 2.154 2.122 2.095 2.054 2.010 1.962 1.938 1.912 1.885 1.857 1.828 1.797 15 3.073 2.695 2.490 2.361 2.273 2.208 2.158 2.119 2.086 2.059 2.017 1.972 1.924 1.899 1.873 1.845 1.817 1.787 1.755 16 3.048 2.668 2.462 2.333 2.244 2.178 2.128 2.088 2.055 2.028 1.985 1.940 1.891 1.866 1.839 1.811 1.782 1.751 1.718 17 3.026 2.645 2.437 2.308 2.218 2.152 2.102 2.061 2.028 2.001 1.958 1.912 1.862 1.836 1.809 1.781 1.751 1.719 1.686 18 3.007 2.624 2.416 2.286 2.196 2.130 2.079 2.038 2.005 1.977 1.933 1.887 1.837 1.810 1.783 1.754 1.723 1.691 1.657 19 2.990 2.606 2.397 2.266 2.176 2.109 2.058 2.017 1.984 1.956 1.912 1.865 1.814 1.787 1.759 1.730 1.699 1.666 1.631 20 2.975 2.589 2.380 2.249 2.158 2.091 2.040 1.999 1.965 1.937 1.892 1.845 1.794 1.767 1.738 1.708 1.677 1.643 1.607 21 2.961 2.575 2.365 2.233 2.142 2.075 2.023 1.982 1.948 1.920 1.875 1.827 1.776 1.748 1.719 1.689 1.657 1.623 1.586 20 2.949 2.561 2.351 2.219 2.128 2.061 2.008 1.967 1.933 1.904 1.859 1.811 1.759 1.731 1.702 1.671 1.639 1.604 1.567 23 2.937 2.549 2.339 2.207 2.115 2.047 1.995 1.953 1.919 1.890 1.845 1.796 1.744 1.716 1.686 1.655 1.622 1.587 1.549 24 2.927 2.538 2.327 2.195 2.103 2.035 1.983 1.941 1.906 1.877 1.832 1.783 1.730 1.702 1.672 1.641 1.607 1.571 1.533 25 2.918 2.528 2.317 2.184 2.092 2.024 1.971 1.929 1.895 1.866 1.820 1.771 1.718 1.689 1.659 1.627 1.593 1.557 1.518 26 2.909 2.519 2.307 2.174 2.082 2.014 1.961 1.919 1.884 1.855 1.809 1.760 1.706 1.677 1.647 1.615 1.581 1.544 1.504 27 2.901 2.511 2.299 2.165 2.073 2.005 1.952 1.909 1.874 1.845 1.799 1.749 1.695 1.666 1.636 1.603 1.569 1.531 1.491 28 2.894 2.503 2.291 2.157 2.064 1.996 1.943 1.900 1.865 1.836 1.790 1.740 1.685 1.656 1.625 1.593 1.558 1.520 1.478 29 2.887 2.495 2.283 2.149 2.057 1.988 1.935 1.892 1.857 1.827 1.781 1.731 1.676 1.647 1.616 1.583 1.547 1.509 1.467 30 2.881 2.489 2.276 2.142 2.049 1.980 1.927 1.884 1.849 1.819 1.773 1.722 1.667 1.638 1.606 1.573 1.538 1.499 1.456 40 2.835 2.440 2.226 2.091 1.997 1.927 1.873 1.829 1.793 1.763 1.715 1.662 1.605 1.574 1.541 1.506 1.467 1.425 1.377 60 2.791 2.393 2.177 2.041 1.946 1.875 1.819 1.775 1.738 1.707 1.657 1.603 1.543 1.511 1.476 1.437 1.395 1.348 1.291 120 2.748 2.347 2.130 1.992 1.896 1.824 1.767 1.722 1.684 1.652 1.601 1.545 1.482 1.447 1.409 1.368 1.320 1.265 1.193 1000+ 2.706 2.303 2.084 1.945 1.847 1.774 1.717 1.670 1.632 1.599 1.546 1.487 1.421 1.383 1.342 1.295 1.240 1.169 1.000
Annex 4B - Appendix A.2 Table A.2.3 Critical F values, Fcrit95, versus N-1 and Nref-1 at 95 per cent confidence
N-1 1 2 3 4 5 6 7 8 9 10 12 15 20 24 30 40 60 120 1000+ Nref-1 1 161.4 199.5 215.7 224.5 230.1 233.9 236.7 238.8 240.5 241.8 243.9 245.9 248.0 249.0 250.1 251.1 252.2 253.2 254.3 2 18.51 19.00 19.16 19.24 19.29 19.33 19.35 19.37 19.38 19.39 19.41 19.42 19.44 19.45 19.46 19.47 19.47 19.48 19.49 3 10.12 9.552 9.277 9.117 9.014 8.941 8.887 8.845 8.812 8.786 8.745 8.703 8.660 8.639 8.617 8.594 8.572 8.549 8.526 4 7.709 6.944 6.591 6.388 6.256 6.163 6.094 6.041 5.999 5.964 5.912 5.858 5.803 5.774 5.746 5.717 5.688 5.658 5.628 5 6.608 5.786 5.410 5.192 5.050 4.950 4.876 4.818 4.773 4.735 4.678 4.619 4.558 4.527 4.496 4.464 4.431 4.399 4.365 6 5.987 5.143 4.757 4.534 4.387 4.284 4.207 4.147 4.099 4.060 4.000 3.938 3.874 3.842 3.808 3.774 3.740 3.705 3.669 7 5.591 4.737 4.347 4.120 3.972 3.866 3.787 3.726 3.677 3.637 3.575 3.511 3.445 3.411 3.376 3.340 3.304 3.267 3.230 8 5.318 4.459 4.066 3.838 3.688 3.581 3.501 3.438 3.388 3.347 3.284 3.218 3.150 3.115 3.079 3.043 3.005 2.967 2.928 9 5.117 4.257 3.863 3.633 3.482 3.374 3.293 3.230 3.179 3.137 3.073 3.006 2.937 2.901 2.864 2.826 2.787 2.748 2.707 10 4.965 4.103 3.708 3.478 3.326 3.217 3.136 3.072 3.020 2.978 2.913 2.845 2.774 2.737 2.700 2.661 2.621 2.580 2.538 11 4.844 3.982 3.587 3.357 3.204 3.095 3.012 2.948 2.896 2.854 2.788 2.719 2.646 2.609 2.571 2.531 2.490 2.448 2.405 12 4.747 3.885 3.490 3.259 3.106 2.996 2.913 2.849 2.796 2.753 2.687 2.617 2.544 2.506 2.466 2.426 2.384 2.341 2.296 13 4.667 3.806 3.411 3.179 3.025 2.915 2.832 2.767 2.714 2.671 2.604 2.533 2.459 2.420 2.380 2.339 2.297 2.252 2.206 14 4.600 3.739 3.344 3.112 2.958 2.848 2.764 2.699 2.646 2.602 2.534 2.463 2.388 2.349 2.308 2.266 2.223 2.178 2.131 15 4.543 3.682 3.287 3.056 2.901 2.791 2.707 2.641 2.588 2.544 2.475 2.403 2.328 2.288 2.247 2.204 2.160 2.114 2.066 16 4.494 3.634 3.239 3.007 2.852 2.741 2.657 2.591 2.538 2.494 2.425 2.352 2.276 2.235 2.194 2.151 2.106 2.059 2.010 17 4.451 3.592 3.197 2.965 2.810 2.699 2.614 2.548 2.494 2.450 2.381 2.308 2.230 2.190 2.148 2.104 2.058 2.011 1.960 18 4.414 3.555 3.160 2.928 2.773 2.661 2.577 2.510 2.456 2.412 2.342 2.269 2.191 2.150 2.107 2.063 2.017 1.968 1.917 19 4.381 3.522 3.127 2.895 2.740 2.628 2.544 2.477 2.423 2.378 2.308 2.234 2.156 2.114 2.071 2.026 1.980 1.930 1.878 20 4.351 3.493 3.098 2.866 2.711 2.599 2.514 2.447 2.393 2.348 2.278 2.203 2.124 2.083 2.039 1.994 1.946 1.896 1.843 21 4.325 3.467 3.073 2.840 2.685 2.573 2.488 2.421 2.366 2.321 2.250 2.176 2.096 2.054 2.010 1.965 1.917 1.866 1.812 22 4.301 3.443 3.049 2.817 2.661 2.549 2.464 2.397 2.342 2.297 2.226 2.151 2.071 2.028 1.984 1.938 1.889 1.838 1.783 23 4.279 3.422 3.028 2.796 2.640 2.528 2.442 2.375 2.320 2.275 2.204 2.128 2.048 2.005 1.961 1.914 1.865 1.813 1.757 24 4.260 3.403 3.009 2.776 2.621 2.508 2.423 2.355 2.300 2.255 2.183 2.108 2.027 1.984 1.939 1.892 1.842 1.790 1.733 25 4.242 3.385 2.991 2.759 2.603 2.490 2.405 2.337 2.282 2.237 2.165 2.089 2.008 1.964 1.919 1.872 1.822 1.768 1.711 26 4.225 3.369 2.975 2.743 2.587 2.474 2.388 2.321 2.266 2.220 2.148 2.072 1.990 1.946 1.901 1.853 1.803 1.749 1.691 27 4.210 3.354 2.960 2.728 2.572 2.459 2.373 2.305 2.250 2.204 2.132 2.056 1.974 1.930 1.884 1.836 1.785 1.731 1.672 28 4.196 3.340 2.947 2.714 2.558 2.445 2.359 2.291 2.236 2.190 2.118 2.041 1.959 1.915 1.869 1.820 1.769 1.714 1.654 29 4.183 3.328 2.934 2.701 2.545 2.432 2.346 2.278 2.223 2.177 2.105 2.028 1.945 1.901 1.854 1.806 1.754 1.698 1.638 30 4.171 3.316 2.922 2.690 2.534 2.421 2.334 2.266 2.211 2.165 2.092 2.015 1.932 1.887 1.841 1.792 1.740 1.684 1.622 40 4.085 3.232 2.839 2.606 2.450 2.336 2.249 2.180 2.124 2.077 2.004 1.925 1.839 1.793 1.744 1.693 1.637 1.577 1.509 60 4.001 3.150 2.758 2.525 2.368 2.254 2.167 2.097 2.040 1.993 1.917 1.836 1.748 1.700 1.649 1.594 1.534 1.467 1.389 120 3.920 3.072 2.680 2.447 2.290 2.175 2.087 2.016 1.959 1.911 1.834 1.751 1.659 1.608 1.554 1.495 1.429 1.352 1.254 1000+ 3.842 2.996 2.605 2.372 2.214 2.099 2.010 1.938 1.880 1.831 1.752 1.666 1.571 1.517 1.459 1.394 1.318 1.221 1.000
Annex 4B - Appendix A.2
A.2.6. Slope The least-squares regression slope, a1y, shall be calculated as follows: N
∑( y − y )⋅( y i refi − yref ) a1 y = i =1 N (A.2-8) ∑( y − yref ) refi i =1
A.2.7. Intercept The least-squares regression intercept, a0y, shall be calculated as follows:
a0 y = y − ( a1 y ⋅ yref ) (A.2-9)
A.2.8. Standard estimate of error The standard estimate of error, SEE, shall be calculated as follows: N
∑ ⎡⎣ y − a − ( a ⋅ y )⎤⎦ i 0y 1y refi SEE y = i =1 (A.2-10) N−2 A.2.9. Coefficient of determination The coefficient of determination, r2, shall be calculated as follows: N
∑ ⎡⎣ y − a − ( a ⋅ y )⎤⎦ i 0y 1y refi ry2 = 1 − i =1 N (A.2-11) ∑[ y − y ] i i =1
Annex 4B - Appendix A.3
Annex 4B - Appendix A.3
1980 international gravity formula The acceleration of Earth's gravity, ag, varies depending on the location and ag is calculated for a respective latitude, as follows:
ag = 9.7803267715 ⎡⎣1 + 5.2790414 ×10−3 sin 2 θ + 2.32718 ×10−5 sin 4 θ + 1.262 ×10−7 sin 6 θ + 7 ×10−10 sin 8 θ ⎤⎦ (A.3-1)
where: θ = Degrees north or south latitude
Annex 4B - Appendix A.4
Annex 4B - Appendix A.4
Carbon flow check A.4.1. Introduction All but a tiny part of the carbon in the exhaust comes from the fuel, and all but a minimal part of this is manifest in the exhaust gas as CO2. This is the basis for a system verification check based on CO2 measurements. The flow of carbon into the exhaust measurement systems is determined from the fuel flow rate. The flow of carbon at various sampling points in the emissions and particulate sampling systems is determined from the CO2 concentrations and gas flow rates at those points. In this sense, the engine provides a known source of carbon flow, and observing the same carbon flow in the exhaust pipe and at the outlet of the partial flow PM sampling system verifies leak integrity and flow measurement accuracy. This check has the advantage that the components are operating under actual engine test conditions of temperature and flow. Figure A.4.1 shows the sampling points at which the carbon flows shall be checked. The specific equations for the carbon flows at each of the sample points are given in the following paragraphs.
Figure A.4.1 Measuring points for carbon flow check location 1 location 2 Air Fuel Raw exhaust CO2
ENGINE
location 3 Diluted exhaust CO2
Partial Flow System
A.4.2. Carbon flow rate into the engine (location 1) The carbon mass flow rate into the engine qmCf [kg/s] for a fuel CHαOε is given by: 12.011 qmCf = ⋅ q mf (A.4-1) 12.011 + α + 15.9994 ⋅ ε where: qmf = uel mass flow rate [kg/s]
Annex 4B - Appendix A.4
A.4.3. Carbon flow rate in the raw exhaust (location 2) The carbon mass flow rate in the exhaust pipe of the engine qmCe [kg/s] shall be determined from the raw CO2 concentration and the exhaust gas mass flow rate:
⎛c −c ⎞ 12.011 qmCe = ⎜ CO2,r CO2,a ⎟ ⋅ qmew ⋅ (A.4-2) ⎝ 100 ⎠ Me where: cCO2,r = wet CO2 concentration in the raw exhaust gas [per cent] cCO2,a = wet CO2 concentration in the ambient air [per cent] qmew = exhaust gas mass flow rate on wet basis [kg/s] Me = molar mass of exhaust gas [g/mol] If CO2 is measured on a dry basis it shall be converted to a wet basis according to paragraph A.7.3.2. or A.8.2.2. A.4.4. Carbon flow rate in the dilution system (location 3) For the partial flow dilution system, the splitting ratio also needs to be taken into account. The carbon flow rate in an equivalent dilution system qmCp [kg/s] (with equivalent meaning equivalent to a full flow system where the total flow is diluted) shall be determined from the dilute CO2 concentration, the exhaust gas mass flow rate and the sample flow rate; the new equation is identical to equation A.4-2, being only supplemented by the dilution factor qmdew qmp .
⎛c −c ⎞ 12.011 qmdew qmCp = ⎜ CO2,d CO2,a ⎟ ⋅ qmew ⋅ ⋅ (A.4-3) ⎝ 100 ⎠ Me qmp where: cCO2,d = wet CO2 concentration in the dilute exhaust gas at the outlet of the dilution tunnel [per cent] cCO2,a = wet CO2 concentration in the ambient air [per cent] qmdew = diluted sample flow in the partial flow dilution system [kg/s] qmew = exhaust gas mass flow rate on wet basis [kg/s] qmp = sample flow of exhaust gas into partial flow dilution system [kg/s] Me = molar mass of exhaust gas [g/mol] If CO2 is measured on a dry basis, it shall be converted to wet basis according to paragraph A.7.3.2. or A.8.2.2. A.4.5. Calculation of the molar mass of the exhaust gas The molar mass of the exhaust gas shall be calculated according to equation (A.8-15) (see paragraph A.8.2.4.2.) Alternatively, the following exhaust gas molar masses may be used: Me (diesel) = 28.9 g/mol
Annex 4B - Appendix A.5
Annex 4B - Appendix A.5
(Reserved)
Annex 4B - Appendix A.6
Annex 4B - Appendix A.6
(Reserved)
Annex 4B - Appendix A.7
Annex 4B - Appendix A.7
Molar based emission calculations A.7.0. Symbol conversion A.7.0.1. General symbols
Appendix A.7 Appendix A.8 Unit Quantity
A m2 Area
At m2 Venturi throat cross-sectional area
a0 b, D0 t.b.d.7 y intercept of the regression line, PDP calibration intercept
a1 m t.b.d.7 Slope of the regression line
β rD m/m Ratio of diameters
C - Coefficient
Cd Cd - Discharge coefficient
Cf - Flow coefficient
d d m Diameter
DR rd - Dilution ratio2
e e g/kWh Brake specific basis
egas egas g/kWh Specific emission of gaseous components
ePM ePM g/kWh Specific emission of particulates
f Hz Frequency
fn n min-1, s-1 Rotational frequency (shaft)
γ - Ratio of specific heats
K Correction factor
Ks X0 s/rev PDP slip correction factor
kDr kDr - Downward adjustment factor
kh Humidity correction factor for NOx
kr kr - Multiplicative regeneration factor
kUr kUr - Upward adjustment factor
µ µ kg/(m·s) Dynamic viscosity
Annex 4B - Appendix A.7
Appendix A.7 Appendix A.8 Unit Quantity
M M g/mol Molar mass3
Mgas4 Mgas g/mol Molar mass of gaseous components
m m kg Mass
m& qm kg/s Mass rate
ν m2/s Kinematic viscosity
N Total number in series
n mol Amount of substance
n& mol/s Amount of substance rate
P P kW Power
p p kPa Pressure
pabs pp kPa Absolute pressure
pH2O pr kPa Water vapour pressure
PF 1–E per cent Penetration fraction (E = conversion efficiency)
V& qV m³/s Volume flow rate
ρ ρ kg/m³ Mass density
r - Ratio of pressures
Ra µm Average surface roughness
Re# Re - Reynolds number
RH% RH per cent Relative humidity
σ σ - Standard deviation
S K Sutherland constant
T Ta K Absolute temperature
T T °C Temperature
T N·m Engine torque
t t s Time
Δt Δt s Time interval
V V m3 Volume
V& qV m3/s Volume rate
W W kWh Work
Annex 4B - Appendix A.7
Appendix A.7 Appendix A.8 Unit Quantity
Wact Wact kWh Actual cycle work of the test cycle
WF WF - Weighing factor
w w g/g Mass fraction
X5 c mol/mol, Amount of substance mole fraction6 / concentration (also in µmol/mol = ppm) per cent vol
x mol/mol Flow-weighted mean concentration
y - Generic variable
y - Arithmetic mean
Z - Compressibility factor
See subscripts; e.g.: m& air for mass rate of dry air or m & fuel for fuel mass rate. Dilution ratio rd in Appendix A.8 and DR in Appendix A.7: different symbols but same meaning and same equations. Dilution factor D in Appendix A.8 and xdil/exh in Appendix A.7: different symbols but same physical meaning; equation (A.7-47) shows the relationship between xdil/exh and DR. See paragraph A.7.1.1. of this section for the values to use for molar masses. In the cases of NOx and HC, the Regulations specify effective molar masses based on assumed speciation rather than actual speciation. See symbols and abbreviations for the chemical components. See specific symbols in the table of chemical balance. The mole fractions for THC and NMHC are expressed on a C1 equivalent basis. t.b.d.= to be defined.
A.7.0.2. Subscripts
Appendix A.7 Appendix A.8 Quantity
abs Absolute quantity
act act Actual quantity
air Air, dry
atmos Atmospheric
bkgnd Background
C Carbon
cal Calibration quantity
CFV Critical flow venturi
cor Corrected quantity
dil Dilution air
dexh Diluted exhaust
Annex 4B - Appendix A.7
Appendix A.7 Appendix A.8 Quantity
dry Dry quantity
exh Raw exhaust
exp Expected quantity
eq Equivalent quantity
fuel Fuel
i Instantaneous measurement (e.g.: 1 Hz)
i An individual of a series
idle Condition at idle
in Quantity in
init Initial quantity, typically before an emission test
max Maximum (i.e. peak) value
meas Measured quantity
min Minimum value
mix Molar mass of air
out Quantity out
part Partial quantity
PDP Positive displacement pump
raw Raw exhaust
ref Reference quantity
rev Revolution
sat Saturated condition
slip PDP slip
smpl Sampling
span Span quantity
SSV Subsonic venturi
std Standard quantity
test Test quantity
total Total quantity
uncor Uncorrected quantity
Annex 4B - Appendix A.7
Appendix A.7 Appendix A.8 Quantity
vac Vacuum quantity
weight Calibration weight
wet Wet quantity
zero Zero quantity In Appendix A.8 the meaning of subscript is determined by the associated quantity; for example, the subscript "d" can indicate a dry basis as in "cd = concentration on dry basis", dilution air as in "pd = saturation vapour pressure of the dilution air" or "kw,d = dry to wet correction factor for the dilution air", dilution ratio as in "rd". This is the reason why the column of Appendix A.8 is nearly empty.
A.7.0.3. Symbols and abbreviations for the chemical components (used also as a subscript)
Appendix A.7 Appendix A.8 Quantity
Ar Ar Argon
C1 C1 Carbon 1 equivalent hydrocarbon
CH4 CH4 Methane
C2H6 C2H6 Ethane
C3H8 C3H8 Propane
CO CO Carbon monoxide
CO2 CO2 Carbon dioxide
DOP DOP Di-octylphthalate
H Atomic hydrogen
H2 Molecular hydrogen
HC HC Hydrocarbon
H2O H2O Water
He Helium
N Atomic nitrogen
N2 Molecular nitrogen
NMHC NMHC Non-methane hydrocarbon
NOx NOx Oxides of nitrogen
NO NO Nitric oxide
NO2 NO2 Nitrogen dioxide
Annex 4B - Appendix A.7
Appendix A.7 Appendix A.8 Quantity
O Atomic oxygen
PM PM Particulate matter
S Sulphur
A.7.0.4. Symbols and abbreviations for the fuel composition 1 2 Appendix A.7 Appendix A.8 Quantity 4 4 wC wC Carbon content of fuel, mass fraction [g/g] or [per cent mass]
wH wH Hydrogen content of fuel, mass fraction [g/g] or [per cent mass]
wN wN Nitrogen content of fuel, mass fraction [g/g] or [per cent mass]
wO wO Oxygen content of fuel, mass fraction [g/g] or [per cent mass]
wS wS Sulphur content of fuel, mass fraction [g/g] or [per cent mass]
α α Atomic hydrogen-to-carbon ratio (H/C)
β ε Atomic oxygen-to-carbon ratio (O/C)3
γ γ Atomic sulphur-to-carbon ratio (S/C)
δ δ Atomic nitrogen-to-carbon ratio (N/C) Referred to a fuel with chemical formula CHαOβSγNδ Referred to a fuel with chemical formula CHαOεNδSγ Attention should be paid to the different meaning of symbol β in the two emissions calculation annexes: in Appendix A.8 it refers to a fuel having the chemical formula CHαSγNδOε (i.e. the formula CβHαSγNδOε where β = 1, assuming one carbon atom per molecule), while in Appendix A.7 it refers to the oxygen-to-carbon ratio with CHαOβSγNδ. Then β of Appendix A.7 corresponds to ε of Appendix A.8. Mass fraction w accompanied by the symbol of the chemical component as a subscript.
A.7.0.5. Symbols for chemical balance used in Appendix A.7 xdil/exh = Amount of dilution gas or excess air per mole of exhaust xH2Oexh = Amount of water in exhaust per mole of exhaust xCcombdry = Amount of carbon from fuel in the exhaust per mole of dry exhaust xH2Oexhdry = Amount of water in exhaust per dry mole of dry exhaust xprod/intdry = Amount of dry stoichiometric products per dry mole of intake air xdil/exhdry = Amount of dilution gas and/or excess air per mole of dry exhaust xint/exhdry = Amount of intake air required to produce actual combustion products per mole of dry (raw or diluted) exhaust
Annex 4B - Appendix A.7
xraw/exhdry = Amount of undiluted exhaust, without excess air, per mole of dry (raw or diluted) exhaust xO2intdry = Amount of intake air O2 per mole of dry intake air xCO2intdry = Amount of intake air CO2 per mole of dry intake air xH2Ointdry = Amount of intake air H2O per mole of dry intake air xCO2int = Amount of intake air CO2 per mole of intake air xCO2dil = Amount of dilution gas CO2 per mole of dilution gas xCO2dildry = Amount of dilution gas CO2 per mole of dry dilution gas xH2Odildry = Amount of dilution gas H2O per mole of dry dilution gas xH2Odil = Amount of dilution gas H2O per mole of dilution gas x[emission]meas = Amount of measured emission in the sample at the respective gas analyser x[emission]dry = Amount of emission per dry mole of dry sample xH2O[emission]meas = Amount of water in sample at emission-detection location xH2Oint = Amount of water in the intake air, based on a humidity measurement of intake air A.7.1. Basic parameters and relationships A.7.1.1. Dry air and chemical species This annex uses the following values for dry air composition: xO2airdry = 0.209445 mol/mol xCO2airdry = 0.000375 mol/mol
This annex uses the following molar masses or effective molar masses of chemical species: Mair = 28.96559 g/mol (dry air) MAr = 39.948 g/mol (argon) MC = 12.0107 g/mol (carbon) MCO = 28.0101 g/mol (carbon monoxide) MCO2 = 44.0095 g/mol (carbon dioxide) MH = 1.00794 g/mol (atomic hydrogen) MH2 = 2.01588 g/mol (molecular hydrogen) MH2O = 18.01528 g/mol (water) MHe = 4.002602 g/mol (helium) MN = 14.0067 g/mol (atomic nitrogen) MN2 = 28.0134 g/mol (molecular nitrogen) MNMHC = 13.875389 g/mol (non-methane hydrocarbon(a)) MNOx = 46.0055 g/mol (oxides of nitrogen(b))
Annex 4B - Appendix A.7
MO = 15.9994 g/mol (atomic oxygen) MO2 = 31.9988 g/mol (molecular oxygen) MC3H8 = 44.09562 g/mol (propane) MS = 32.065 g/mol (sulphur) MTHC = 13.875389 g/mol (total hydrocarbon(a))
(a) The effective molar masses of THC and NMHC are defined by an atomic hydrogen-to-carbon ratio, α, of 1.85;
(b) The effective molar mass of NOx is defined by the molar mass of nitrogen dioxide, NO2. This annex uses the following molar gas constant R for ideal gases: R = 8.314472 J ( mol ⋅ K )
This annex uses the following ratios of specific heats γ ⎡⎣ J ( kg ⋅ K ) ⎤⎦ ⎡⎣ J ( kg ⋅ K ) ⎤⎦ for dilution air and diluted exhaust:
γair = 1.399 (ratio of specific heats for intake air or dilution air) γdil = 1.399 (ratio of specific heats for diluted exhaust) γdil = 1.385 (ratio of specific heats for raw exhaust) A.7.1.2. Wet air This section describes how to determine the amount of water in an ideal gas: A.7.1.2.1. Vapour pressure of water The vapour pressure of water pH2O [kPa] for a given saturation temperature condition, Tsat [K], shall be calculated as follows:
(a) For humidity measurements made at ambient temperatures from 0 to 100 °C or for humidity measurements made over super-cooled water at ambient temperatures from –50 to 0 °C: ⎛ 273.16 ⎞ ⎛ Tsat ⎞ log10 ( pH2O ) = 10.79574 ⋅ ⎜ 1 − ⎟ − 5.02800 ⋅ log10 ⎜ ⎟+ ⎝ Tsat ⎠ ⎝ 273.16 ⎠ ⎛ −8.2969⋅⎜ sat −1⎟ ⎞ ⎛ T ⎞ ⎛ 4.76955⋅⎛⎜1− 273.16 ⎞⎟ ⎞ +1.50475 ⋅10 −4 ⋅ ⎜ 1 − 10 ⎟ + 0.42873 ⋅10 −3 ⋅ ⎜ 10 − 1⎟ − 0.2138602 ⎝ 273.16 ⎠ ⎝ Tsat ⎠ ⎜ ⎟ ⎜ ⎟ ⎝ ⎠ ⎝ ⎠ (A.7-1) where: pH2O = vapour pressure of water at saturation temperature condition [kPa] Tsat = saturation temperature of water at measured condition [K]
Annex 4B - Appendix A.7
(b) For humidity measurements made over ice at ambient temperatures from (-100 to 0) °C: ⎛ 273.16 ⎞ ⎛ 273.16 ⎞ ⎛ Tsat ⎞ log10 ( psat ) = −9.096853 ⋅ ⎜ − 1⎟ − 3.566506 ⋅ log10 ⎜ ⎟ + 0.876812 ⋅ ⎜1 − ⎟ − 0.2138602 ⎝ Tsat ⎠ ⎝ Tsat ⎠ ⎝ 273.16 ⎠
(A.7-2) where: Tsat = saturation temperature of water at measured condition [K] A.7.1.2.2. Dew point If humidity is measured as a dew point, the amount of water in an ideal gas xH2O [mol/mol] shall be obtained as follows: pH2O xH2O = (A.7-3) pabs where: xH2O = amount of water in an ideal gas [mol/mol] pH2O = vapour pressure of water at the measured dew point, Tsat=Tdew [kPa] pabs = wet static absolute pressure at the location of dew point measurement [kPa] A.7.1.2.3. Relative humidity If humidity is measured as a relative humidity RH%, the amount of water of an ideal gas xH2O [mol/mol] is calculated as follows: RH% pH2O xH2O = ⋅ (A.7-4) 100 pabs where: RH% = relative humidity [per cent] pH2O = water vapour pressure at 100 per cent relative humidity at the location of relative humidity measurement, Tsat=Tamb [kPa] pabs = wet static absolute pressure at the location of relative humidity measurement [kPa] A.7.1.3. Fuel properties The general chemical formula of fuel is CHαOβSγNδ with α atomic hydrogen- to-carbon ratio (H/C), β atomic oxygen-to-carbon ratio (O/C), γ atomic sulphur- to-carbon ratio (S/C) and δ atomic nitrogen-to-carbon ratio (N/C). Based on this formula the carbon mass fraction of fuel wC can be calculated. In case of diesel fuel the simple formula CHαOβ may be used. Default values for fuel composition may be used as follows:
Annex 4B - Appendix A.7
Table A.7.1 Default values of atomic hydrogen-to-carbon ratio, α, atomic oxygen-to-carbon ratio, β, and carbon mass fraction of fuel, wC for diesel fuels
Atomic hydrogen and oxygen-to-carbon ratios Carbon mass concentration, wC Fuel CHαOβ [g/g]
Diesel CH1.85O0 0.866
A.7.1.4. Total HC and non-methane HC concentration A.7.1.4.1. THC determination and THC/CH4 initial contamination corrections
(a) If THC emissions are required to be determined, xTHC[THC-FID] shall be calculated by using the initial THC contamination concentration xTHC[THC-FID]init from paragraph 7.3.1.2. as follows:
xTHC[THC-FID]cor = xTHC[THC-FID]uncorr − xTHC[THC-FID]init (A.7-5)
where: xTHC[THC-FID]cor = THC concentration corrected for contamination [mol/mol] xTHC[THC-FID]uncorr = THC uncorrected concentration [mol/mol] xTHC[THC-FID]init = initial THC contamination concentration [mol/mol]
(b) For the NMHC determination described in paragraph A.7.1.4.2., xTHC[THC-FID] shall be corrected for initial HC contamination using equation (A.7-5). The initial contamination of the CH4 sample train may be corrected using equation (A.7-5), substituting in CH4 concentrations for THC. A.7.1.4.2. NMHC determination To determine NMHC concentration, xNMHC, one of the following shall be used:
(a) If CH4 is not measured, NMHC concentrations may be determined as follows: The background corrected mass of NMHC shall be compared to background corrected mass of THC. If the background corrected mass of NMHC is greater than 0.98 times the background corrected mass of THC, the background corrected mass of NMHC shall be taken as 0.98 times the background corrected mass of THC. If the NMHC calculations are omitted, the background corrected mass of NMHC shall be taken as 0.98 times the background corrected mass of THC;
(b) For non-methane cutters, xNMHC shall be calculated using the non- methane cutter's penetration fractions (PF) of CH4 and C2H6 from paragraph 8.1.10.3., and using the HC contamination and dry-to-wet corrected THC concentration xTHC[THC-FID]cor as determined in sub- paragraph (a) of paragraph of A.7.1.4.1.:
Annex 4B - Appendix A.7
(i) The following equation for penetration fractions determined using an NMC configuration as outlined in paragraph 8.1.10.3.4.1. shall be used: xTHC[THC-FID]cor − xTHC[NMC-FID] ⋅ RFCH4[THC-FID] xNMHC = (A.7-6) 1 − RFPFC2H6[NMC-FID] ⋅ RFCH4[THC-FID] where: xNMHC = concentration of NMHC xTHC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID during sampling while bypassing the NMC xTHC[NMC-FID] = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC RFCH4[THC-FID] = response factor of THC FID to CH4, according to paragraph 8.1.10.1.4. RFPFC2H6[NMC-FID] = non-methane cutter combined ethane response factor and penetration fraction, according to paragraph 8.1.10.3.4.1.
(ii) For penetration fractions determined using an NMC configuration as outlined in paragraph 8.1.10.3.4.2., the following equation shall be used: xTHC[THC-FID]cor ⋅ PFCH4[NMC-FID] − xTHC[NMC-FID] xNMHC = (A.7-7) PFCH4[NMC-FID] − PFC2H6[NMC-FID]
where: xNMHC = concentration of NMHC xTHC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID during sampling while bypassing the NMC PFCH4[NMC-FID] = non-methane cutter CH4 penetration fraction, according to paragraph 8.1.10.3.4.2. xTHC[NMC-FID] = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC PFC2H6[NMC-FID] = non-methane cutter ethane penetration fraction, according to paragraph 8.1.10.3.4.2.
(iii) For penetration fractions determined using an NMC configuration as outlined in paragraph 8.1.10.3.4.3., the following equation shall be used:
Annex 4B - Appendix A.7
xTHC[THC-FID]cor ⋅ PFCH4[NMC-FID] − xTHC[NMC-FID] ⋅ RFCH4[THC-FID] xNMHC = PFCH4[NMC-FID] − RFPFC2H6[NMC-FID] ⋅ RFCH4[THC-FID] (A.7-8) where: xNMHC = concentration of NMHC xTHC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID during sampling while bypassing the NMC PFCH4[NMC-FID] = non-methane cutter CH4 penetration fraction, according to paragraph 8.1.10.3.4.3. xTHC[NMC-FID] = concentration of THC, HC contamination (optional) and dry-to-wet corrected, as measured by the NMC FID during sampling through the NMC RFPFC2H6[NMC-FID] = non-methane cutter CH4 combined ethane response factor and penetration fraction, according to paragraph 8.1.10.3.4.3. RFCH4[THC-FID] = response factor of THC FID to CH4, according to paragraph 8.1.10.1.4.
(c) For a gas chromatograph, xNMHC shall be calculated using the THC analyser's response factor (RF) for CH4, from paragraph 8.1.10.1.4., and the HC contamination and dry-to-wet corrected initial THC concentration xTHC[THC-FID]cor as determined in paragraph (a) above as follows:
xNMHC = xTHC[THC-FID]cor − RFCH4[THC-FID] ⋅ xCH4 (A.7-9)
where: xNMHC = concentration of NMHC xTHC[THC-FID]cor = concentration of THC, HC contamination and dry-to-wet corrected, as measured by the THC FID xCH4 = concentration of CH4, HC contamination (optional) and dry-to-wet corrected, as measured by the gas chromatograph FID RFCH4[THC-FID] = response factor of THC-FID to CH4 A.7.1.4.3. Approximation of NMHC from THC NMHC (non-methane hydrocarbon) emissions can be approximated as 98 percent of THC (total hydrocarbon).
Annex 4B - Appendix A.7
A.7.1.5. Flow-weighted mean concentration In some paragraphs of this annex, it may be necessary to calculate a flow- weighted mean concentration to determine the applicability of certain provisions. A flow-weighted mean is the mean of a quantity after it is weighted proportional to a corresponding flow rate. For example, if a gas concentration is measured continuously from the raw exhaust of an engine, its flow-weighted mean concentration is the sum of the products of each recorded concentration times its respective exhaust molar flow rate, divided by the sum of the recorded flow rate values. As another example, the bag concentration from a CVS system is the same as the flow-weighted mean concentration because the CVS system itself flow-weights the bag concentration. A certain flow-weighted mean concentration of an emission at its standard might be already expected based on previous testing with similar engines or testing with similar equipment and instruments. A.7.2. Chemical balances of fuel, intake air, and exhaust A.7.2.1. General Chemical balances of fuel, intake air and exhaust may be used to calculate flows, the amount of water in their flows, and the wet concentration of constituents in their flows. With one flow rate of either fuel, intake air or exhaust, chemical balances may be used to determine the flows of the other two. For example, chemical balances along with either intake air or fuel flow to determine raw exhaust flow may be used. A.7.2.2. Procedures that require chemical balances Chemical balances are required to determine the following:
(a) The amount of water in a raw or diluted exhaust flow, xH2Oexh, when the amount of water to correct for the amount of water removed by a sampling system is not measured;
(b) The flow-weighted mean fraction of dilution air in diluted exhaust, xdil/exh, when dilution air flow is not measured to correct for background emissions. It has to be noted that if chemical balances are used for this purpose, the exhaust is assumed to be stoichiometric, even if it is not. A.7.2.3. Chemical balance procedure The calculations for a chemical balance involve a system of equations that require iteration. The initial values of up to three quantities shall be guessed: the amount of water in the measured flow, xH2Oexh, fraction of dilution air in diluted exhaust (or excess air in the raw exhaust), xdil/exh, and the amount of products on a C1 basis per dry mole of dry measured flow, xCcombdry. Time- weighted mean values of combustion air humidity and dilution air humidity in the chemical balance may be used; as long as combustion air and dilution air humidity remain within tolerances of ± 0.0025 mol/mol of their respective mean values over the test interval. For each emission concentration, x, and amount of water xH2Oexh, it shall be determined their completely dry concentrations, xdry and xH2Oexhdry. It shall also be used fuel's atomic hydrogen- to-carbon ratio, α, oxygen-to-carbon ratio, β and carbon mass fraction of fuel, wC. For the test fuel, α and β or the default values in Table 7.1 may be used.
Annex 4B - Appendix A.7
Use the following steps to complete a chemical balance:
(a) Measured concentrations such as, xCO2meas, xNOmeas, and xH2Oint, shall be converted to dry concentrations by dividing them by one minus the amount of water present during their respective measurements; for example: xH2OxCO2meas, xH2OxNOmeas, and xH2Oint. If the amount of water present during a "wet" measurement is the same as the unknown amount of water in the exhaust flow, xH2Oexh, it has to be iteratively solved for that value in the system of equations. If only total NOx are measured and not NO and NO2 separately, good engineering judgement shall be used to estimate a split in the total NOx concentration between NO and NO2 for the chemical balances. The molar concentration of NOx, xNOx, may be assumed to be 75 per cent NO and 25 per cent NO2. For NO2 storage aftertreatment systems, xNOx may be assumed to be 25 per cent NO and 75 per cent NO2. For calculating the mass of NOx emissions, the molar mass of NO2 for the effective molar mass of all NOx species, regardless of the actual NO2 fraction of NOx, shall be used;
(b) Equations (A.7-10 to A.7-26) in paragraph (d) of this paragraph A.7.2.3. have to be entered into a computer program to iteratively solve for xH2Oexh, xCcombdry and xdil/exh. Good engineering judgment shall be used to guess initial values for xH2Oexh, xCcombdry, and xdil/exh. Guessing an initial amount of water that is about twice the amount of water in the intake or dilution air is recommended. Guessing an initial value of xCcombdry as the sum of the measured CO2, CO, and THC values is recommended. Guessing an initial xdil between 0.75 and 0.95 ( 0.75 < xdil < 0.95 ), such as 0.8 is also recommended. Values in the system of equations shall be iterated until the most recently updated guesses are all within ±1 per cent of their respective most recently calculated values;
(c) The following symbols and subscripts are used in the equation system of sub-paragraph (c) of this paragraph where x unit is mol/mol:
Symbol Description
xdil/exh Amount of dilution gas or excess air per mole of exhaust
xH2Oexh Amount of H2O in exhaust per mole of exhaust
xCcombdry Amount of carbon from fuel in the exhaust per mole of dry exhaust
xH2Oexhdry Amount of water in exhaust per dry mole of dry exhaust
xprod/intdry Amount of dry stoichiometric products per dry mole of intake air
xdil/exhdry Amount of dilution gas and/or excess air per mole of dry exhaust
xint/exhdry Amount of intake air required to produce actual combustion products per mole of dry (raw or diluted) exhaust
xraw/exhdry Amount of undiluted exhaust, without excess air, per mole of dry (raw or diluted) exhaust
xO2intdry Amount of intake air O2 per mole of dry intake air; xO2intdry = 0.209445 mol/mol may be assumed
Annex 4B - Appendix A.7
Symbol Description
xCO2intdry Amount of intake air CO2 per mole of dry intake air. xCO2intdry = 375 μmol/mol may be used, but measuring the actual concentration in the intake air is recommended
xH2Ointdry Amount of the intake air H2O per mole of dry intake air
xCO2int Amount of intake air CO2 per mole of intake air
xCO2dil Amount of dilution gas CO2 per mole of dilution gas
xCO2dildry Amount of dilution gas CO2 per mole of dry dilution gas. If air is used as diluent, xCO2dildry = 375 μmol/mol may be used, but measuring the actual concentration in the intake air is recommended
xH2Odildry Amount of dilution gas H2O per mole of dry dilution gas
xH2Odil Amount of dilution gas H2O per mole of dilution gas
x[emission]meas Amount of measured emission in the sample at the respective gas analyser
x[emission]dry Amount of emission per dry mole of dry sample
xH2O[emission]meas Amount of water in sample at emission-detection location. These values shall be measured or estimated according to paragraph 9.3.2.3.1.
xH2Oint Amount of water in the intake air, based on a humidity measurement of intake air α Atomic hydrogen-to-carbon ratio of the mixture of fuel(s) ( CHα O β ) being combusted, weighted by molar consumption
β Atomic oxygen-to-carbon ratio of the mixture of fuel(s) ( CHα O β ) being combusted, weighted by molar consumption
(d) The following equations shall be used to iteratively solve for xdil/exh, xH2Oexh and xCcombdry: xraw/exhdry xdil/exh = 1 − (A.7-10) 1 + xH2Oexhdry
xH2Oexhdry xH2Oexh = (A.7-11) 1 + xH2Oexhdry
xCcombdry = xCO2dry + xCOdry + xTHCdry − xCO2dil ⋅ xdil/exhdry − xCO2int ⋅ xint/exhdry (A.7-12) α xH2Oexhdry = (xCcombdry − xTHCdry ) + xH2Odil ⋅ xdil/exhdry + xH2Oint ⋅ xint/exhdry (A.7-13)
Annex 4B - Appendix A.7
xdil/exh xdil/exhdry = (A.7-14) 1 − xH2Oexh
1 ⎡⎛ α ⎞ ⎤ xint/exhdry = ⎜ − β + 2 ⎟ ( xCcombdry − xTHCdry ) − ( xCOdry − xNOdry − 2 xNO2dry ) ⎥ 2 ⋅ xO2int ⎢⎣⎝ 2 ⎠ ⎦ (A.7-15)
1 ⎡⎛ α ⎞ ⎤ xraw/exhdry = ⎜ + β ⎟ ( xCcombdry − xTHCdry ) + ( 2 xTHCdry + xCOdry − xNO2dry ) ⎥ + xint/exhdry 2 ⎢⎣⎝ 2 ⎠ ⎦ (A.7-16) 0.209820 − xCO2intdry (A.7-17) xO2int = 1 + xH2Ointdry
xCO2intdry xCO2int = (A.7-18) 1 + xH2Ointdry xH2Oint xH2Ointdry = (A.7-19) 1 − xH2Oint xCO2dildry xCO2dil = (A.7-20) 1 + xH2Odildry xH2Odil xH2Odildry = (A.7-21) 1 − xH2Odil xCOmeas xCOdry = (A.7-22) 1 − xH2OCOmeas xCO2meas xCO2dry = (A.7-23) 1 − xH2OCO2meas xNOmeas xNOdry = (A.7-24) 1 − xH2ONOmeas xNO2meas xNO2dry = (A.7-25) 1 − xH2ONO2meas xTHCmeas xTHCdry = (A.7-26) 1 − xH2OTHCmeas At the end of the chemical balance, the molar flow rate n&exh is calculated as specified in paragraphs A.7.3.3. and A.7.4.3.
Annex 4B - Appendix A.7
A.7.2.4. NOx correction for humidity All the NOx concentrations, including dilution air background concentrations, shall be corrected for intake-air humidity using the following equation:
xNOxcor = xNOxuncor ⋅ ( 9.953 ⋅ xH2O + 0.832 ) (A.7-27)
where: xNOxuncor = uncorrected NOx molar concentration in the exhaust gas [µmol/mol] xH2O = amount of water in the intake air [mol/mol] A.7.3. Raw gaseous emissions A.7.3.1. Mass of gaseous emissions To calculate the total mass per test of gaseous emission mgas [g/test], its molar concentration shall be multiplied by its respective molar flow and by exhaust gas molar mass; then integration over test cycle shall be performed:
mgas = M gas ⋅ ∫ n&exh ⋅ xgas ⋅ dt (A.7-28)
where: Mgas = molar mass of the generic gaseous emission [g/mol]
n&exh = instantaneous exhaust gas molar flow rate on a wet basis [mol/s]
xgas = instantaneous generic gas molar concentration on a wet basis [mol/mol] t = time [s] Since equation (A.7-28) has to be solved by numerical integration, it is transformed in: N mgas = M gas ⋅ ∫ n&exh ⋅ xgas ⋅ dt ⇒ mgas = 1 ⋅ M gas ⋅ ∑ n&exhi ⋅ xgasi (A.7-29) f i =1
where: Mgas = generic emission molar mass [g/mol]
n&exhi = instantaneous exhaust gas molar flow rate on a wet basis [mol/s]
xgasi = instantaneous generic gas molar concentration on a wet basis [mol/mol] f = data sampling rate [Hz] N = number of measurements [-] General equation may be modified according to which measurement system is used, batch or continuous sampling, and if a varying rather than a constant flow rate is sampled.
(a) For continuous sampling, in the general case of varying flow rate, the mass of the gaseous emission mgas [g/test] shall be calculated by means of the following equation:
Annex 4B - Appendix A.7
N mgas = ⋅ M gas ⋅ ∑ n&exhi ⋅ xgasi (A.7-30) f i =1
where: Mgas = generic emission molar mass [g/mol]
n&exhi = instantaneous exhaust gas molar flow rate on a wet basis [mol/s] xgasi = instantaneous gaseous emission molar fraction on a wet basis [mol/mol] f = data sampling rate [Hz] N = number of measurements [-]
(b) Still for continuous sampling but in the particular case of constant flow rate the mass of the gaseous emission mgas [g/test] shall be calculated by means of the following equation: mgas = M gas ⋅ n&exh ⋅ xgas ⋅ Δt (A.7-31)
where: Mgas = generic emission molar mass [g/mol]
n&exh = exhaust gas molar flow rate on a wet basis [mol/s]
xgas = mean gaseous emission molar fraction on a wet basis [mol/mol] Δt = time duration of test interval
(c) For the batch sampling, regardless the flow rate is varying or constant, the equation (A.7-30) can be simplified as follows:
1 N mgas = ⋅ M gas ⋅ xgas ⋅ ∑ n&exhi (A.7-32) f i =1
where: Mgas = generic emission molar mass [g/mol]
n&exhi = instantaneous exhaust gas molar flow rate on a wet basis [mol/s]
xgas = mean gaseous emission molar fraction on a wet basis [mol/mol] F = data sampling rate [Hz] N = number of measurements [-]
Annex 4B - Appendix A.7
A.7.3.2. Dry-to-wet concentration conversion Parameters of this paragraph are obtained from the results of the chemical balance calculated in paragraph A.7.2. The following relation exists between gas molar concentrations in the measured flow xgasdry and xgas [mol/mol] expressed on a dry and wet basis respectively: xgas xgasdry = (A.7-33) 1 − xH2O xgasdry xgas = (A.7-34) 1 + xH2Odry where: xH2O = molar fraction of water in the measured flow on a wet basis [mol/mol] xH2Odry = molar fraction of water in the measured flow on a dry basis [mol/mol] For gaseous emissions a removed water correction shall be performed for the generic concentration x [mol/mol] as follows: ⎡ (1 − xH2Oexh ) ⎤ x = x[emission]meas ⎢ ⎥ (A.7-35) ⎢⎣1 − xH2O[emission]meas ⎥⎦
where: x[emission]meas = molar fraction of emission in the measured flow at measurement location [mol/mol] xH2O[emission]meas = amount of water in the measured flow at the concentration measurement [mol/mol] xH2Oexh = amount of water at the flow-meter [mol/mol] A.7.3.3. Exhaust gas molar flow rate The flow rate of the raw exhaust gases can be directly measured or can be calculated based on the chemical balance of paragraph A.7.2.3. Calculation of raw exhaust molar flow rate is performed from measured intake air molar flow rate or fuel mass flow rate. The raw exhaust molar flow rate can be calculated from the sampled emissions, n&exh , based on the measured intake air molar flow rate, n&int , or the measured fuel mass flow rate, m & fuel , and the values calculated using the chemical balance in paragraph A.7.2.3. It shall be solved for the chemical balance in paragraph A.7.2.3. at the same frequency that n&int or m & fuel is updated and recorded.
(a) Crankcase flow rate. The raw exhaust flow can be calculated based on n&int or m& fuel only if at least one of the following is true about crankcase emission flow rate:
(i) The test engine has a production emission-control system with a closed crankcase that routes crankcase flow back to the intake air, downstream of intake air flow-meter;
Annex 4B - Appendix A.7
(ii) During emission testing open crankcase flow are routed to the exhaust according to paragraph 6.10;
(iii) Open crankcase emissions and flow are measured and added brake-specific emission calculations;
(iv) Using emission data or an engineering analysis, it can be demonstrated that neglecting the flow rate of open crankcase emissions does not adversely affect compliance with the applicable standards;
(b) Molar flow rate calculation based on intake air.
Based on n&int , exhaust gas molar flow rate n&exh [mol/s] shall be calculated as follows: n&int (A.7-36) n&exh = ⎡ ( xint/exhdry − xraw/exhdry ) ⎤ ⎢1 + ⎥ ⎢⎣ (1 + xH2Oexhdry ) ⎥⎦ where:
n&exh = raw exhaust molar flow rate from which emissions are measured [mol/s]
n&int = intake air molar flow rate including humidity in intake air [mol/s] xint/exhdry = amount of intake air required to produce actual combustion products per mole of dry (raw or diluted) exhaust [mol/mol] xraw/exhdry = amount of undiluted exhaust, without excess air, per mole of dry (raw or diluted) exhaust [mol/mol] xH2Oexhdry = amount of water in exhaust per mole of dry exhaust [mol/mol]
(c) Molar flow rate calculation based on fuel mass flow rate
Based on m & fuel , n&exh [mol/s] shall be calculated as follows:
m& fuel ⋅ wC ⋅ (1 + xH2Oexhdry ) n&exh = (A.7-37) M C ⋅ xCcombdry where:
n&exh = raw exhaust molar flow rate from which emissions are measured
m& fuel = fuel flow rate including humidity in intake air [g/s]
wC = carbon mass fraction for the given fuel [g/g] xH2Oexhdry = amount of H2O per dry mole of measured flow [mol/mol]
Annex 4B - Appendix A.7
MC = molecular mass of carbon 12.0107 g/mol xCcombdry = amount of carbon from fuel in the exhaust per mole of dry exhaust [mol/mol] A.7.4. Diluted gaseous emissions A.7.4.1. Emission mass calculation and background correction Equations for the calculation of gaseous emissions mass mgas [g/test] as a function of molar emissions flow rates are as follows:
(a) Continuous sampling, varying flow rate N mgas = ⋅ M gas ⋅ ∑ n&exhi ⋅ xgasi (see A.7-29) f i =1
where: Mgas = generic emission molar mass [g/mol]
n& exhi = instantaneous exhaust gas molar flow rate on a wet basis [mol/s] mgasi = instantaneous generic gas molar concentration on a wet basis [mol/mol] f = data sampling rate [Hz] N = number of measurements [-] Continuous sampling, constant flow rate
mgas = M gas ⋅ n&exh ⋅ xgas ⋅ Δt (see A.7-31)
where: Mgas = generic emission molar mass [g/mol]
n& exh = exhaust gas molar flow rate on a wet basis [mol/s]
xgas = mean gaseous emission molar fraction on a wet basis [mol/mol] Δt = time duration of test interval
(b) Batch sampling, regardless varying flow or constant rate is the following equation shall be used: N mgas = ⋅ M gas ⋅ xgas ⋅ ∑ n&exhi (see A.7-32) f i =1
where: Mgas = generic emission molar mass [g/mol]
n& exhi = instantaneous exhaust gas molar flow rate on a wet basis [mol/s]
Annex 4B - Appendix A.7
xgas = mean gaseous emission molar fraction on a wet basis [mol/mol] f = data sampling rate [Hz] N = number of measurements [-]
(c) In case of diluted exhaust gases calculated values for mass of the pollutants shall be corrected by subtracting the mass of background emissions, due to dilution air:
(i) Firstly, the molar flow rate of dilution air n&airdil [mol/s] shall be determined over the test interval. This may be a measured quantity or a quantity calculated from the diluted exhaust flow and the flow-weighted mean fraction of dilution air in diluted exhaust, xdil/exh ;
(ii) The total flow of dilution air nairdil [mol] shall be multiplied by the mean concentration of background emission. This may be a time-weighted mean or a flow-weighted mean (e.g., a proportionally sampled background). The product of nairdil and the mean concentration of a background emission is the total amount of a background emission;
(iii) If the result is a molar quantity, it shall be converted to a mass of the background emission mbkgnd [g] by multiplying it by emission molar mass, Mgas [g/mol];
(iv) Total background mass shall be subtracted from total mass to correct for background emissions;
(v) The total flow of dilution air may be determined by a direct flow measurement. In this case, the total mass of background shall be calculated, using the dilution air flow, nairdil. The background mass shall be subtracted from the total mass. The result shall be used in brake-specific emission calculations;
(vi) The total flow of dilution air may be determined from the total flow of diluted exhaust and a chemical balance of the fuel, intake air, and exhaust as described in paragraph A.7.2. In this case, the total mass of background shall be calculated, using the total flow of diluted exhaust, ndexh. Then this result shall be multiplied by the flow-weighted mean fraction of dilution air in diluted exhaust, xdil/exh .
Considering the two cases (v) and (vi), the following equations shall be used:
mbkgnd = M gas ⋅ xgasdil ⋅ nairdil or mbkgnd = M gas ⋅ xdil/exh ⋅ xbkgnd ⋅ ndexh (A.7-38)
mgascor = mgas − mbkgnd (A.7-39)
Annex 4B - Appendix A.7
where: mgas = total mass of the gaseous emission [g] mbkgnd = total background masses [g] mgascor = mass of gas corrected for background emissions [g] Mgas = molecular mass of generic gaseous emission [g/mol] xgasdil = gaseous emission concentration in dilution air [mol/mol] nairdil = dilution air molar flow [mol]
xdil/exh = flow-weighted mean fraction of dilution air in diluted exhaust [mol/mol] xbkgnd = gas fraction of background [mol/mol]
ndexh = total flow of diluted exhaust [mol] A.7.4.2. Dry-to wet concentration conversion The same relations for raw gases (paragraph A.7.3.2.) shall be used for dry-to- wet conversion on diluted samples. For dilution air a humidity measurement shall be performed with the aim to calculate its water vapour fraction xH2Odildry [mol/mol]: xH2Odil xH2Odildry = (see A.7-21) 1 − xH2Odil where: xH2Odil = water molar fraction in the dilution air flow [mol/mol] A.7.4.3. Exhaust molar flow rate
(a) Calculation via chemical balance;
The molar flow rate n&exh [mol/s] can be calculated based on fuel mass flow rate m & fuel :
m& fuel ⋅ wC ⋅ (1 + xH2Oexhdry ) n&exh = (see A.7-37) M C ⋅ xCcombdry where: n&exh = raw exhaust molar flow rate from which emissions are measured m& fuel = fuel flow rate including humidity in intake air [g/s] wC = carbon mass fraction for the given fuel [g/g] xH2Oexhdry = amount of H2O per dry mole of measured flow [mol/mol] MC = molecular mass of carbon 12.0107 g/mol xCcombdry = amount of carbon from fuel in the exhaust per mole of dry exhaust [mol/mol]
Annex 4B - Appendix A.7
(b) Measurement The exhaust gas molar flow rate may be measured by means of three systems:
(i) PDP molar flow rate. Based upon the speed at which the Positive Displacement Pump (PDP) operates for a test interval, the corresponding slope a1, and intercept, a0 [-], as calculated with the calibration procedure of Appendix 1 to this annex, shall be used to calculate molar flow rate n& [mol/s] as follows:
pin ⋅Vrev n& = f n,PDP ⋅ (A.7-40) R ⋅ Tin where:
a1 pout − pin Vrev = ⋅ + a0 (A.7-41) f n,PDP pin where: a1 = calibration coefficient [m3/s] a0 = calibration coefficient [m3/rev] pin, pout = inlet/outlet pressure [Pa] R = molar gas constant [J/(mol K)] Tin = inlet temperature [K] Vrev = PDP pumped volume [m3/rev] fn.,PDP = PDP speed [rev/s]
(ii) SSV molar flow rate. Based on the Cd versus Re# equation determined according to Appendix 1 of this annex, the Sub- Sonic Venturi (SSV) molar flow rate during an emission test n& [mol/s] shall be calculated as follows: At ⋅ pin (A.7-42) n& = Cd ⋅ Cf ⋅ Z ⋅ M mix ⋅ R ⋅ Tin
where: pin = inlet pressure [Pa] At = Venturi throat cross-sectional area [m2] R = molar gas constant [J/(mol K)] Tin = inlet temperature [K] Z = compressibility factor Mmix = molar mass of diluted exhaust [kg/mol] Cd = discharge coefficient of the SSV [-] Cf = flow coefficient of the SSV [-]
Annex 4B - Appendix A.7
(iii) CFV molar flow rate. To calculate the molar flow rate through one venturi or one combination of venturis, its respective mean Cd and other constants, determined according to the Appendix 1 to this annex, shall be used. The calculation of its molar flow rate n& [mol/s] during an emission test follows: At ⋅ pin n& = Cd ⋅ Cf ⋅ (A.7-43) Z ⋅ M mix ⋅ R ⋅ Tin
where: pin = inlet pressure [Pa] At = Venturi throat cross-sectional area [m2] R = molar gas constant [J/(mol K)] Tin = inlet temperature [K] Z = compressibility factor Mmix = molar mass of diluted exhaust [kg/mol] Cd = discharge coefficient of the CFV [-] Cf = flow coefficient of the CFV [-] A.7.4.4. Determination of particulates A.7.4.4.1. Sampling
(a) Sampling from a varying flow rate: If a batch sample from a changing exhaust flow rate is collected, a sample proportional to the changing exhaust flow rate shall be extracted. The flow rate shall be integrated over a test interval to determine the total flow. The mean PM concentration M PM (which is already in units of mass per mole of sample) shall be multiplied by the total flow to obtain the total mass of PM mPM [g]: N mPM = M PM ⋅ ∑ ( n&i ⋅ Δti ) (A.7-44) i =1
where:
n&i = instantaneous exhaust molar flow rate [mol/s]
M PM = mean PM concentration [g/mol] Δti = sampling interval [s]
(b) Sampling from a constant flow rate If a batch sample from a constant exhaust flow rate is collected, the mean molar flow rate from which the sample is extracted shall be determined. The mean PM concentration shall be multiplied by the total flow to obtain the total mass of PM mPM[g]:
mPM = M PM ⋅ n& ⋅ Δt (A.7-45)
Annex 4B - Appendix A.7
where:
n& = exhaust molar flow rate [mol/s]
M PM = mean PM concentration [g/mol] Δt = time duration of test interval [s] For sampling with a constant dilution ratio (DR), mPM [g] shall be calculated using the following equation:
mPM = mPMdil ⋅ DR (A.7-46)
where: mPMdil = PM mass in dilution air [g] DR = dilution ratio [-] defined as the ratio between the mass of the emission m and the mass of diluted exhaust mdil/exh ( DR = m mdil/exh ).
The dilution ratio DR can be expressed as a function of xdil/exh: 1 (A.7-47) DR = 1 − xdil/exh
A.7.4.4.2. Background correction The same approach as that of paragraph A.7.4.1. shall be applied to correct the mass of PM for the background. Multiplying M PMbkgnd by the total flow of dilution air, the total background mass of PM (mPMbkgnd [g]) is obtained. Subtraction of total background mass from total mass gives background corrected mass of particulates mPMcor [g]:
mPMcor = mPMuncor − M PMbkgnd ⋅ nairdil (A.7-48)
where: mPMuncor = uncorrected PM mass [g]
M PMbkgnd = mean PM concentration in dilution air [g/mol]
nairdil = dilution air molar flow [mol] A.7.5. Cycle work and specific emissions A.7.5.1. Gaseous emissions A.7.5.1.1. Transient and ramped modal cycle Reference is made to paragraphs A.7.3.1. and A.7.4.1. for raw and diluted exhaust respectively. The resulting values for power Pi [kW] shall be integrated over a test interval. The total work Wact [kWh] is calculated as follows: N 1 1 1 2⋅π N Wact = ∑ Pi ⋅ Δti = ⋅ ⋅ 3 ∑ ( ni ⋅ Ti ) (A.7-49) i =1 f 3600 10 60 i =1
Annex 4B - Appendix A.7
where: Pi = instantaneous engine power [kW] ni = instantaneous engine speed [min-1] Ti = instantaneous engine torque [N·m] Wact = actual cycle work [kWh] f = data sampling rate [Hz] N = number of measurements [-] The specific emissions egas [g/kWh] shall be calculated in the following ways depending on the type of test cycle. mgas (A.7-50) egas = Wact
where: mgas = total mass of emission [g/test] Wact = cycle work [kWh] In case of the transient cycle, the final test result egas [g/kWh] shall be a weighted average from cold start test and hot start test by using:
egas = ( 0.1⋅ mcold ) + ( 0.9 ⋅ mhot ) (A.7-51) ( 0.1⋅Wactcold ) + ( 0.9 ⋅Wacthot ) In case of an infrequent (periodic) exhaust regeneration (paragraph 6.6.2.), the specific emissions shall be corrected with the multiplicative adjustment factor kr (equation (6-4)) or with the two separate pairs of adjustment additive factors kUr (upward factor of equation (6-5)) and kDr (downward factor of equation (6-6)). A.7.5.1.2. Steady-state discrete-mode cycle The specific emissions egas [g/kWh] are calculated as follows: N mode .
∑ ( m& gasi ⋅ WFi ) (A.7-52) egas = iN=1mode ∑ ( P ⋅WF ) i =1 i i
where:
m& gas,i = mean emission mass flow rate for the mode i [g/h]
Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3. and 7.7.1.2.) WFi = weighing factor for the mode i [-]
Annex 4B - Appendix A.7
A.7.5.2. Particulate emissions A.7.5.2.1. Transient and ramped modal cycles The particulate specific emissions shall be calculated with equation (A.7-50) where egas [g/kWh] and mgas [g/test] are substituted by ePM [g/kWh] and mPM [g/test] respectively: mPM ePM = (A.7-53) Wact where: mPM = total mass of particulates emission, calculated according to paragraph A.8.3.4. [g/test] Wact = cycle work [kWh] The emissions on the transient composite cycle (i.e. cold phase and hot phase) shall be calculated as shown in paragraph A.7.5.1. A.7.5.2.2. Steady state discrete-mode cycle The particulate specific emission ePM [g/kWh] shall be calculated in the following way: A.7.5.2.2.1. For the single-filter method m& PM (A.7-54) ePM = N
∑ ( P ⋅ WF ) i =1 i i
where:
Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3. and 7.7.1.2.) WFi = weighing factor for the mode i [-]
m& PM = particulate mass flow rate [g/h]
A.7.5.2.2.2. For the multiple-filter method N
∑ ( m& PMi ⋅ WFi ) (A.7-55) ePM = i =1N ∑ ( P ⋅ WF ) i =1 i i
where:
Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3. and 7.7.1.2.) WFi = weighing factor for the mode i [-]
m& PMi = particulate mass flow rate at mode i [g/h]
Annex 4B - Appendix A.7
For the single-filter method, the effective weighing factor, WFeffi, for each mode shall be calculated in the following way:
msmpldexhi ⋅ m& eqdexhwet WFeffi = (A.7-56) msmpldex ⋅ m& eqdexhweti where: msmpldexhi = mass of the diluted exhaust sample passed through the particulate sampling filters at mode i [kg] msmpldexh = mass of the diluted exhaust sample passed through the particulate sampling filters [kg]
m& eqdexhweti = equivalent diluted exhaust gas mass flow rate at mode i [kg/s]
m& eqdexhwet = average equivalent diluted exhaust gas mass flow rate [kg/s]
The value of the effective weighing factors shall be within ±0.005 (absolute value) of the weighing factors listed in Annex 5.
Annex 4B - Appendix A.7.1
Annex 4B - Appendix A.7.1
Diluted exhaust flow (CVS) calibration This Appendix 1 describes the calculations for calibrating various flow-meters. Paragraph A.7.6.1. of this Appendix 1 first describes how to convert reference flow-meter outputs for use in the calibration equations, which are presented on a molar basis. The remaining paragraphs describe the calibration calculations that are specific to certain types of flow-meters. A.7.6.1. Reference meter conversions
The calibration equations in this section use molar flow rate, n&ref , as a reference quantity. If he adopted reference meter outputs a flow rate in a different quantity, such as standard volume rate, V&stdref , actual volume rate, V&actdref , or mass rate, m& ref , the reference meter output shall be converted to a molar flow rate using the following equations, noting that while values for volume rate, mass rate, pressure, temperature, and molar mass may change during an emission test, they should be kept as constant as practical for each individual set point during a flow-meter calibration:
V&stdref ⋅ pstd V&actref ⋅ pact m& n&ref = = = ref (A.7-57) Tstd ⋅ R Tact ⋅ R M mix where:
n&ref = reference molar flow rate [mol/s]
V&stdref = reference volume flow rate, corrected to a standard pressure and a standard temperature [m3/s]
V&actref = reference volume flow rate, at the actual pressure and temperature [m3/s]
m& ref = reference mass flow [g/s]
pstd = standard pressure [Pa] pact = actual pressure of the gas [Pa] Tstd = standard temperature [K] Tact = actual temperature of the gas [K] R = molar gas constant [ J/(mol ⋅ K) ]
Mmix = molar mass of the gas [g/mol]
Annex 4B - Appendix A.7.1
A.7.6.2. PDP calibration calculations For each restrictor position, the following values shall be calculated from the mean values determined in paragraph 8.1.8.4., as follows:
(a) PDP volume pumped per revolution, Vrev (m3/rev):
n&ref ⋅ R ⋅ Tin Vrev = (A.7-58) pin ⋅ f nPDP where:
n&ref = mean value of reference molar flow rate [mol/s]
R = molar gas constant [ J/(mol ⋅ K)]
Tin = mean inlet temperature [K]
pin = mean inlet pressure [Pa]
f nPDP = mean rotational speed [rev/s]
(b) PDP slip correction factor, Ks [s/rev]:
1 pout − pin Ks = ⋅ (A.7-59) f nPDP pout where:
n&ref = mean reference molar flow rate [mol/s]
Tin = mean inlet temperature [K]
pin = mean inlet pressure [Pa]
pout = mean outlet pressure [Pa]
f nPDP = mean PDP revolution speed [rev/s]
R = molar gas constant [ J/(mol ⋅ K)]
(c) A least-squares regression of PDP volume pumped per revolution, Vrev, versus PDP slip correction factor, Ks, shall be performed by calculating slope, a1, and intercept, a0, as described in Annex 4B Appendix A.2;
(d) The procedure in sub-paragraphs (a) through (c) of this paragraph shall be repeated for every speed that PDP is operated;
(e) The following table illustrates these calculations for different values of f nPDP :
Annex 4B - Appendix A.7.1
Table A.7.2 Example of PDP calibration data
f nPDP [rev/min] f nPDP [rev/s] a1 [m3/min] a1 [m3/s] a0 [m3/rev]
755.0 12.58 50.43 0.8405 0.056
987.6 16.46 49.86 0.831 -0.013
1254.5 20.9 48.54 0.809 0.028
1401.3 23.355 47.30 0.7883 -0.061
(f) For each speed at which the PDP is operated, the corresponding slope, a1, and intercept, a0, shall be used to calculate flow rate during emission testing as described in paragraph A.7.4.3.(b) A.7.6.3. Venturi governing equations and permissible assumptions This section describes the governing equations and permissible assumptions for calibrating a venturi and calculating flow using a venturi. Because a subsonic venturi (SSV) and a critical-flow venturi (CFV) both operate similarly, their governing equations are nearly the same, except for the equation describing their pressure ratio, r (i.e., rSSV versus rCFV). These governing equations assume one-dimensional isentropic inviscid compressible flow of an ideal gas. In paragraph A.7.6.3.(d), other assumptions that may be made are described. If the assumption of an ideal gas for the measured flow is not allowed, the governing equations include a first-order correction for the behaviour of a real gas; namely, the compressibility factor, Z. If good engineering judgment dictates using a value other than Z = 1, an appropriate equation of state to determine values of Z as a function of measured pressures and temperatures may be used, or specific calibration equations may be developed based on good engineering judgment. It shall be noted that the equation for the flow coefficient, Cf, is based on the ideal gas assumption that the isentropic exponent, γ, is equal to the ratio of specific heats, cp/cV. If good engineering judgment dictates using a real gas isentropic exponent, an appropriate equation of state to determine values of γ as a function of measured pressures and temperatures may be used, or specific calibration equations may be developed. Molar flow rate, n& [mol/s], shall be calculated as follows: At ⋅ pin n& = Cd ⋅ Cf ⋅ (A.7-60) Z ⋅ M mix ⋅ R ⋅ Tin where: Cd = Discharge coefficient, as determined in paragraph A.7.6.3.(a) [-] Cf = Flow coefficient, as determined in paragraph A.7.6.3.(b) [-] At = Venturi throat cross-sectional area [m2] pin = Venturi inlet absolute static pressure [Pa] Z = Compressibility factor [-]
Annex 4B - Appendix A.7.1
Mmix = Molar mass of gas mixture [kg/mol] R = Molar gas constant [ J/(mol ⋅ K)]
Tin = Venturi inlet absolute temperature [K]
(a) Using the data collected in paragraph 8.1.8.4., Cd is calculated using the following equation:
Z ⋅ M mix ⋅ R ⋅ Tin Cd = n&ref ⋅ (A.7-61) Cf ⋅ At ⋅ pin where:
n&ref = reference molar flow rate [mol/s] Other symbols as per equation (A.7-60).
(b) Cf shall be determined using one of the following methods:
(i) For CFV flow-meters only, CfCFV is derived from the following table based on values for β (ratio of venturi throat to inlet diameters) and γ (ratio of specific heats of the gas mixture), using linear interpolation to find intermediate values:
Table A.7.3 CfCFV versus β and γ for CFV flow-meters
CfCFV
β γexh =1.385 γdexh =γair=1.399
0.000 0.6822 0.6846
0.400 0.6857 0.6881
0.500 0.6910 0.6934
0.550 0.6953 0.6977
0.600 0.7011 0.7036
0.625 0.7047 0.7072
0.650 0.7089 0.7114
0.675 0.7137 0.7163
Annex 4B - Appendix A.7.1
CfCFV
β γexh =1.385 γdexh =γair=1.399
0.700 0.7193 0.7219
0.720 0.7245 0.7271
0.740 0.7303 0.7329
0.760 0.7368 0.7395
0.770 0.7404 0.7431
0.780 0.7442 0.7470
0.790 0.7483 0.7511
0.800 0.7527 0.7555
0.810 0.7573 0.7602
0.820 0.7624 0.7652
0.830 0.7677 0.7707
0.840 0.7735 0.7765
0.850 0.7798 0.7828
(ii) For any CFV or SSV flow-meter, the following equation may be used to calculate Cf: ⎡ ⎛ γ −1 ⎞ ⎤ 2 ⎢ 2 ⋅ γ ⋅ ⎜ r γ − 1⎟ ⋅ ⎥ ⎢ ⎜ ⎟ ⎥ Cf = ⎢ ⎝ ⎠ (A.7-62) −2 ⎥ ⎢ ( γ − 1) ⋅ ⎛⎜ β 4 − r γ ⎞⎟ ⎥ ⎢ ⎜ ⎟⎥ ⎣ ⎝ ⎠⎦ where: γ = isentropic exponent [-]. For an ideal gas, this is the ratio of specific heats of the gas mixture, cp/cV r = pressure ratio, as determined in sub-paragraph (c)(3) of this section β = ratio of venturi throat to inlet diameters
Annex 4B - Appendix A.7.1
(c) The pressure ratio r shall be calculated as follows:
(i) For SSV systems only, rSSV is calculated using the following equation: Δp (A.7-63) rSSV = 1 − SSV pin
where: ΔpSSV = differential static pressure; venturi inlet minus venturi throat [Pa]
(ii) For CFV systems only, rCFV shall be calculated iteratively using the following equation: 1−γ 2 ⎛ γ −1 ⎞ 4 γ +1 rCFV γ + ⎜ ⎟ ⋅ β ⋅ rCFV = γ (A.7-64) ⎝ 2 ⎠ 2
(d) Any of the following simplifying assumptions of the governing equations may be made, or good engineering judgment may be used to develop more appropriate values for testing:
(i) For emission testing over the full ranges of raw exhaust, diluted exhaust and dilution air, the gas mixture may be assumed to behave as an ideal gas: Z = 1;
(ii) For the full range of raw exhaust a constant ratio of specific heats of γ = 1.385 may be assumed;
(iii) For the full range of diluted exhaust and air (e.g., calibration air or dilution air), a constant ratio of specific heats of γ =1.399 may be assumed;
(iv) For the full range of diluted exhaust and air, the molar mass of the mixture, Mmix [g/mol], may be considered as a function only of the amount of water in the dilution air or calibration air, xH2O, determined as described in paragraph A.7.1.2., as follows: M mix = M air ⋅ (1 − xH2O ) + M H2O ⋅ ( xH2O ) (A.7-65)
where: Mair = 28.96559 g/mol MH2O = 18.01528 g/mol xH2O = amount of water in the dilution or calibration air [mol/mol]
(v) For the full range of diluted exhaust and air, a constant molar mass of the mixture, Mmix, may be assumed for all calibration and all testing as long as assumed molar mass differs no more than ±1 per cent from the estimated minimum and maximum molar mass during calibration and testing. This assumption may be made if sufficient control of the amount of water in calibration air and in dilution air is ensured, or if sufficient water is removed from both calibration air and dilution air. The following table gives examples of permissible ranges of dilution air dew point versus calibration air dew point.
Annex 4B - Appendix A.7.1
Table A.7.4 Examples of dilution air and calibration air dew points at which a constant Mmix may be assumed
the following constant Mmix for the following ranges of Tdew (°C) during If calibration Tdew (°C) is... a (g/mol) is assumed emission tests
dry 28.96559 dry to 18
0 28.89263 dry to 21
5 28.86148 dry to 22
10 28.81911 dry to 24
15 28.76224 dry to 26
20 28.68685 –8 to 28
25 28.58806 12 to 31
30 28.46005 23 to 34
a Range valid for all calibration and emission testing over the atmospheric pressure range (80,000 to 103,325) kPa.
A.7.6.4 SSV calibration
(a) Molar based approach. To calibrate an SSV flow-meter the following steps shall be performed:
(i) The Reynolds number, Re#, for each reference molar flow rate, shall be calculated using the throat diameter of the venturi, dt. Because the dynamic viscosity, µ, is needed to compute Re#, a specific viscosity model may be used to determine µ for calibration gas (usually air), using good engineering judgment. Alternatively, the Sutherland three-coefficient viscosity model may be used to approximate µ: 4 ⋅ M mix ⋅ n&ref Re# = (A.7-66) π ⋅ dt ⋅ μ where: dt = diameter of the SSV throat [m] Mmix = mixture molar mass [kg/mol]
n&ref = reference molar flow rate [mol/s]
and, using the Sutherland three-coefficient viscosity model: ⎛ T ⎞2 ⎛ T + S ⎞ (A.7-67) μ = μ0 ⎜ in ⎟ ⋅ ⎜ 0 ⎟ ⎝ T0 ⎠ ⎝ Tin + S ⎠
Annex 4B - Appendix A.7.1
where: µ = Dynamic viscosity of calibration gas [kg/(m·s)] µ0 = Sutherland reference viscosity [kg/(m·s)] S = Sutherland constant [K] T0 = Sutherland reference temperature [K] Tin = Absolute temperature at the venturi inlet [K]
Table A.7.5 Sutherland three-coefficient viscosity model parameters
Temp range within ±2 per cent μ0 T0 S error Pressure limit
a Gas kg /(m·s) K K K kPa
Air 1.716 x 10-5 273 111 170 to 1900 ≤ 1800
CO2 1.370 x 10-5 273 222 190 to 1700 ≤ 3600
H2O 1.12 x 10-5 350 1,064 360 to 1500 ≤ 10000
O2 1.919 x 10-5 273 139 190 to 2000 ≤ 2500
N2 1.663 x 10-5 273 107 100 to 1500 ≤ 1600
a Tabulated parameters only for the pure gases, as listed, shall be used. Parameters to calculate viscosities of gas mixtures shall not be combined.
(ii) An equation for Cd versus Re# shall be created, using paired values of (Re#, Cd). Cd is calculated according to equation (A.7-61), with Cf obtained from equation (A.7-62), or any mathematical expression may be used, including a polynomial or a power series. The following equation is an example of a commonly used mathematical expression for relating Cd and Re#;
Cd = a0 − a1 ⋅ (A.7-68) Re #
(iii) A least-squares regression analysis shall be performed to determine the best-fit coefficients to the equation and calculate the equation's regression statistics, the standard estimate error SEE and the coefficient of determination r2, according to Annex 4B, Appendix A.2;
(iv) If the equation meets the criteria of SEE < 0.5% ⋅ n&ref max (or m& refmax ) and r2 ≥ 0.995, the equation may be used to determine Cd for emission tests, as described in A.7.4.3.(b);
Annex 4B - Appendix A.7.1
(v) If the SEE and r2 criteria are not met, good engineering judgment may be used to omit calibration data points to meet the regression statistics. At least seven calibration data points shall be used to meet the criteria;
(vi) If omitting points does not resolve outliers, corrective action shall be taken. For example, another mathematical expression for the Cd versus Re# equation shall be selected, leaks are to be checked, or the calibration process has to be repeated. If the process shall be repeated, tighter tolerances shall be applied to measurements and more time for flows to stabilize shall be allowed;
(vii) Once the equation meets the regression criteria, the equation may be used only to determine flow rates that are within the range of the reference flow rates used to meet the Cd versus Re# equation's regression criteria. A.7.6.5. CFV calibration
(a) Molar based approach. Some CFV flow-meters consist of a single venturi and some consist of multiple venturis, where different combinations of venturis are used to meter different flow rates. For CFV flow-meters that consist of multiple venturis, either calibration of each venturi independently to determine a separate discharge coefficient, Cd, for each venturi, or calibration of each combination of venturis as one venture may be performed. In the case where a combination of venturis is calibrated, the sum of the active venturi throat areas is used as At, the square root of the sum of the squares of the active venturi throat diameters as dt, and the ratio of the venturi throat to inlet diameters as the ratio of the venturi throat to inlet diameters as the ratio of the square root of the sum of the active venture throat diameters (dt) to the diameter of the common entrance to all of the venturis (D). To determine the Cd for a single venturi or a single combination of venturis, the following steps shall be performed:
(i) With the data collected at each calibration set point to an individual Cd for each point shall be calculated using equation (A.7-60);
(ii) The mean and standard deviation of all the Cd values shall be calculated according to equations (A.2-1) and (A.2-2);
(iii) If the standard deviation of all the Cd values is less than or equal to 0.3 per cent of the mean Cd, then the mean Cd shall be used in equation (A.7-43), and the CFV shall be used only down to the lowest r measured during calibration;
r = 1 − ( Δp pin ) (A.7-69)
(iv) If the standard deviation of all the Cd values exceeds 0.3 per cent of the mean Cd, the Cd values corresponding to the data point collected at the lowest r measured during calibration shall be omitted;
Annex 4B - Appendix A.7.1
(v) If the number of remaining data points is less than seven, corrective action shall be taken by checking calibration data or repeating the calibration process. If the calibration process is repeated, checking for leaks, applying tighter tolerances to measurements and allowing more time for flows to stabilize, is recommended;
(vi) If the number of remaining Cd values is seven or greater, the mean and standard deviation of the remaining Cd values shall be recalculated;
(vii) If the standard deviation of the remaining Cd values is less than or equal to 0.3 per cent of the mean of the remaining Cd, that mean Cd shall be used in equation (A.7-43) and the CFV values only down to the lowest r associated with the remaining Cd shall be used;
(viii) If the standard deviation of the remaining Cd still exceeds 0.3 per cent of the mean of the remaining Cd values, the steps in sub- paragraph (e) (4) through (8) of this section shall be repeated.
Annex 4B - Appendix A.7.2
Annex 4B - Appendix A.7.2
Drift correction A.7.7.1. Scope and frequency The calculations in this Appendix 2 are performed to determine if gas analyser drift invalidates the results of a test interval. If drift does not invalidate the results of a test interval, the test interval's gas analyser responses shall be corrected for drift according to this Appendix 2. The drift-corrected gas analyser responses shall be used in all subsequent emission calculations. The acceptable threshold for gas analyser drift over a test interval is specified in paragraph 8.2.2.2. A.7.7.2. Correction principles The calculations in this Appendix 2 utilize a gas analyser's responses to reference zero and span concentrations of analytical gases, as determined sometime before and after a test interval. The calculations correct the gas analyser's responses that were recorded during a test interval. The correction is based on an analyser's mean responses to reference zero and span gases, and it is based on the reference concentrations of the zero and span gases themselves. Validation and correction for drift shall be performed as follows: A.7.7.3. Drift validation After applying all the other corrections–except drift correction–to all the gas analyser signals, brake-specific emissions shall be calculated according to paragraph A.7.5. of Annex 4B, Appendix A.7. Then all gas analyser signals shall be corrected for drift according to this appendix. Brake-specific emissions shall be recalculated using all of the drift-corrected gas analyser signals. The brake-specific emission results shall be validated and reported before and after drift correction according to paragraph 8.2.2.2. A.7.7.4. Drift correction All gas analyser signals shall be corrected as follows:
(a) Each recorded concentration, xi, shall be corrected for continuous sampling or for batch sampling, x ;
(b) Correction for drift shall be done using the following equation:
2 xi − ( xprezero + xpostzero ) xidriftcor = xrefzero + ( xrefspan − xrefzero ) (A.7-70) (xprespan + xpostspan ) − ( xprezero + xpostzero ) where: xidriftcor = concentration corrected for drift [µmol/mol] xrefzero = reference concentration of the zero gas, which is usually zero unless known to be otherwise [µmol/mol] xrefspan = reference concentration of the span gas [µmol/mol]
Annex 4B - Appendix A.7.2 xprespan = pre-test interval gas analyser response to the span gas concentration [µmol/mol] xpostspan = post-test interval gas analyser response to the span gas concentration [µmol/mol] xi or x = concentration recorded, i.e. measured, during test, before drift correction [µmol/mol] xprezero = pre-test interval gas analyser response to the zero gas concentration [µmol/mol] xpostzero = post-test interval gas analyser response to the zero gas concentration [µmol/mol]
(c) For any pre-test interval concentrations, concentrations determined most recently before the test interval shall be used. For some test intervals, the most recent pre-zero or pre-span might have occurred before one or more previous test intervals;
(d) For any post-test interval concentrations, concentrations determined most recently after the test interval shall be used. For some test intervals, the most recent post-zero or post-span might have occurred after one or more subsequent test intervals;
(e) If any pre-test interval analyser response to the span gas concentration, xprespan, is not recorded, xprespan shall be set equal to the reference concentration of the span gas: xprespan = xrefspan;
(f) If any pre-test interval analyser response to the zero gas concentration, xprezero, is not recorded, xprezero shall be set equal to the reference concentration of the zero gas: xprezero = xrefzero;
(g) Usually the reference concentration of the zero gas, xrefzero, is zero: xrefzero = 0 µmol/mol. However, in some cases it might be known that xrefzero has a non-zero concentration. For example, if a CO2 analyser is zeroed using ambient air, the default ambient air concentration of CO2, which is 375 µmol/mol, may be used. In this case, xrefzero = 375 µmol/mol. When an analyser is zeroed using a non-zero xrefzero, the analyser shall be set to output the actual xrefzero concentration. For example, if xrefzero = 375 µmol/mol, the analyser shall be set to output a value of 375 µmol/mol when the zero gas is flowing to the analyser.
Annex 4B - Appendix A.8
Annex 4B - Appendix A.8
Mass based emission calculations A.8.0. Symbol conversion A.8.0.1. General symbols
Appendix A.8 Appendix A.7 Unit Quantity
b, D0 a0 t.b.d. 3 y intercept of the regression line
m a1 t.b.d.3 Slope of the regression line
A/Fst - Stoichiometric air to fuel ratio
Cd Cd - Discharge coefficient
c x ppm, % vol Concentration (µmol/mol = ppm)
cd 1 ppm, % vol Concentration on dry basis
cw 1 ppm, % vol Concentration on wet basis
cb 1 ppm, % vol Background concentration
D xdil - Dilution factor2
D0 m3/rev PDP calibration intercept
d d m Diameter
dV m Throat diameter of venturi
e e g/kWh Brake specific basis
egas egas g/kWh Specific emission of gaseous components
ePM ePM g/kWh Specific emission of particulates
E 1 – PF per cent Conversion efficiency (PF = Penetration fraction)
Fs - Stoichiometric factor
fc - Carbon factor
H g/kg Absolute humidity
KV ⎡ ⎣ ( K ⋅ m ⋅ s ) /kg ⎤⎦ CFV calibration function
kf m3/kg fuel Fuel specific factor
kh - Humidity correction factor for NOx, diesel engines
Annex 4B - Appendix A.8
Appendix A.8 Appendix A.7 Unit Quantity
kDr kDr - Downward adjustment factor
kr kr - Multiplicative regeneration factor
kUr kUr - Upward adjustment factor
kw,a - Dry to wet correction factor for the intake air
kw,d - Dry to wet correction factor for the dilution air
kw,e - Dry to wet correction factor for the diluted exhaust gas
kw,r - Dry to wet correction factor for the raw exhaust gas
µ µ kg/(m·s) Dynamic viscosity
M M g/mol Molar mass3
Ma 1 g/mol Molar mass of the intake air
Me 1 g/mol Molar mass of the exhaust
Mgas Mgas g/mol Molar mass of gaseous components
m m kg Mass qm m& kg/s Mass rate
md 1 kg Mass of the dilution air sample passed through the particulate sampling filters
med 1 kg Total diluted exhaust mass over the cycle
medf 1 kg Mass of equivalent diluted exhaust gas over the test cycle
mew 1 kg Total exhaust mass over the cycle
mf 1 mg Particulate sample mass collected
mf,d 1 mg Particulate sample mass of the dilution air collected
mgas mgas g Mass of gaseous emissions over the test cycle
mPM mPM g Mass of particulate emissions over the test cycle
mse 1 kg Exhaust sample mass over the test cycle
msed 1 kg Mass of diluted exhaust gas passing the dilution tunnel
msep 1 kg Mass of diluted exhaust gas passing the particulate collection filters
Annex 4B - Appendix A.8
Appendix A.8 Appendix A.7 Unit Quantity
mssd kg Mass of secondary dilution air
n fn min-1 Engine rotational speed
np r/s PDP pump speed
P P kW Power
p p kPa Pressure
pa kPa Dry atmospheric pressure
pb kPa Total atmospheric pressure
pd kPa Saturation vapour pressure of the dilution air
pp pabs kPa Absolute pressure
pr pH2O kPa Water vapour pressure
ps kPa Dry atmospheric pressure
1–E PF per cent Penetration fraction qmad m& 1 kg/s Intake air mass flow rate on dry basis
qmaw 1 kg/s Intake air mass flow rate on wet basis
qmCe 1 kg/s Carbon mass flow rate in the raw exhaust gas
qmCf 1 kg/s Carbon mass flow rate into the engine
qmCp 1 kg/s Carbon mass flow rate in the partial flow dilution system qmdew 1 kg/s Diluted exhaust gas mass flow rate on wet basis
qmdw 1 kg/s Dilution air mass flow rate on wet basis
qmedf 1 kg/s Equivalent diluted exhaust gas mass flow rate on wet basis qmew 1 kg/s Exhaust gas mass flow rate on wet basis
qmex 1 kg/s Sample mass flow rate extracted from dilution tunnel qmf 1 kg/s Fuel mass flow rate
qmp 1 kg/s Sample flow of exhaust gas into partial flow dilution system
qV V& m³/s Volume flow rate
qVCVS 1 m³/s CVS volume rate
Annex 4B - Appendix A.8
Appendix A.8 Appendix A.7 Unit Quantity
qVs 1 dm³/min System flow rate of exhaust analyser system
qVt 1 cm³/min Tracer gas flow rate
ρ ρ kg/m³ Mass density
ρe kg/m³ Exhaust gas density
rd DR - Dilution ratio2
RH per cent Relative humidity
rD β m/m Ratio of diameters (CVS systems)
rp - Pressure ratio of SSV
Re Re# - Reynolds number
σ σ - Standard deviation
T T °C Temperature
Ta K Absolute temperature
t t s Time
Δt Δt s Time interval
u - Ratio between densities of gas component and exhaust gas
V V m3 Volume
qV V& m3/s Volume rate
V0 m3/r PDP gas volume pumped per revolution
W W kWh Work
Wact Wact kWh Actual cycle work of the test cycle
WF WF - Weighing factor
w w g/g Mass fraction
X0 Ks s/rev PDP calibration function
y y Arithmetic mean
See subscripts; e.g.: m & air for mass rate of dry air, m& fuel for fuel mass rate, etc. Dilution ratio rd in Appendix A.8 and DR in Appendix A.7: different symbols but same meaning and same equations. Dilution factor D in Appendix A.8 and xdil in Appendix A.7: different symbols but same physical meaning; equation (A.7-47) shows the relationship between xdil and DR. t.b.d. = to be defined
Annex 4B - Appendix A.8
A.8.0.2. Subscripts Appendix A.8 Appendix A.7 Quantity
act act Actual quantity
i Instantaneous measurement (e.g.: 1 Hz)
i An individual of a series In Appendix A.8 the meaning of subscript is determined by the associated quantity; for example, the subscript "d" can indicate a dry basis as in "cd = concentration on dry basis", dilution air as in "pd = saturation vapour pressure of the dilution air" or "kw,d = dry to wet correction factor for the dilution air", dilution ratio as in "rd".
A.8.0.3. Symbols and abbreviations for the chemical components (used also as a subscript)
Appendix A.8 Appendix A.7 Quantity
Ar Ar Argon
C1 C1 Carbon 1 equivalent hydrocarbon
CH4 CH4 Methane
C2H6 C2H6 Ethane
C3H8 C3H8 Propane
CO CO Carbon monoxide
CO2 CO2 Carbon dioxide
DOP DOP Di-octylphthalate
HC HC Hydrocarbon
H2O H2O Water
NMHC NMHC Non-methane hydrocarbon
NOx NOx Oxides of nitrogen
NO NO Nitric oxide
NO2 NO2 Nitrogen dioxide
PM PM Particulate matter
S S Sulphur
Annex 4B - Appendix A.8
A.8.0.4. Symbols and abbreviations for the fuel composition
1 2 Appendix A.8 Appendix A.7 Quantity
wC4 wC4 Carbon content of fuel, mass fraction [g/g] or [per cent mass]
wH wH Hydrogen content of fuel, mass fraction [g/g] or [per cent mass]
wN wN Nitrogen content of fuel, mass fraction [g/g] or [per cent mass]
wO wO Oxygen content of fuel, mass fraction [g/g] or [per cent mass]
wS wS Sulphur content of fuel, mass fraction [g/g] or [per cent mass]
α α Atomic hydrogen-to-carbon ratio (H/C)
ε β Atomic oxygen-to-carbon ratio (O/C)3
γ γ Atomic sulphur-to-carbon ratio (S/C)
δ δ Atomic nitrogen-to-carbon ratio (N/C) Referred to a fuel with chemical formula CHαOεNδSγ Referred to a fuel with chemical formula CHαOβSγNδ Attention should be paid to the different meaning of symbol β in the two emissions calculation annexes: in Appendix A.8 it refers to a fuel having the chemical formula CHαSγNδOε (i.e. the formula CβHαSγNδOε where β = 1, assuming one carbon atom per molecule), while in Appendix A.7 it refers to the oxygen-to-carbon ratio with CHαOβSγNδ. Then β of Appendix A.7 corresponds to ε of Appendix A.8. Mass fraction w accompanied by the symbol of the chemical component as a subscript.
A.8.1. Basic Parameters A.8.1.1. Determination of methane and non-methane HC concentration The calculation of NMHC and CH4 depends on the calibration method used. The FID for the measurement without NMC, shall be calibrated with propane. For the calibration of the FID in series with NMC, the following methods are permitted:
(a) Calibration gas – propane; propane bypasses NMC,
(b) Calibration gas – methane; methane passes through NMC The concentration of NMHC (cNMHC [-]) and CH4 (cCH4 [-]) shall be calculated as follows for sub-paragraph (a):
cHC(w/oNMC) ⋅ (1 − ECH4 ) − cHC(w/NMC) cNMHC = (A.8-1a) EC2H6 − ECH4
cHC(w/NMC) − cHC(w/oNMC) ⋅ (1 − EC2H6 ) cCH4 = (A.8-2a) RFCH4[THC-FID] ⋅ ( EC2H6 − ECH4 )
Annex 4B - Appendix A.8
The concentration of NMHC and CH4 shall be calculated as follows for sub-paragraph (b):
cHC(w/oNMC) ⋅ (1 − ECH4 ) − cHC(w/NMC) ⋅ RFCH4[THC-FID] ⋅ (1 − ECH4 ) cNMHC = (A.8-1b) EC2H6 − ECH4
cHC(w/NMC) ⋅ RFCH4[THC-FID] ⋅ (1 − ECH4 ) − cHC(w/oNMC) ⋅ (1 − EC2H6 ) cCH4 = (A.8-2b) RFCH4[THC-FID] ⋅ ( EC2H6 − ECH4 )
where: cHC(w/NMC) = HC concentration with sample gas flowing through the NMC [ppm] cHC(w/oNMC) = HC concentration with sample gas bypassing the NMC [ppm] RFCH4[THC-FID] = methane response factor as determined in paragraph 8.1.10.1.4. [-] ECH4 = methane efficiency, as determined in paragraph 8.1.10.3. [-] EC2H6 = ethane efficiency, as determined in paragraph 8.1.10.3. [-] If RFCH4[THC-FID] < 1.05, it may be omitted in equations A.8-1a, A.8-1b and A.8-2b. NMHC (non-methane hydrocarbon) emissions can be approximated as 98 percent of THC (total hydrocarbon). A.8.2. Raw gaseous emissions A.8.2.1. Gaseous emissions A.8.2.1.1. Steady state tests The emission rate of a gaseous emission qmgas,i for each mode i of the steady state test shall be calculated. The concentration of the gaseous emission shall be multiplied by its respective flow:
qmgas,i = kh ⋅ k ⋅ ugas ⋅ qmew,i ⋅ cgas,i ⋅ 3600 (A.8-3)
qmgas,I = emission rate in mode i of the steady state test [g/h] k = 1 for cgasr,w,i in [ppm] and k = 10,000 for cgasr,w,i in [per cent vol] kh = NOx correction factor [-], only to be applied for the NOx emission calculation (see paragraph A.8.2.2.) ugas = component specific factor or ratio between densities of gas component and exhaust gas [-]; to be calculated with equations (A.8-12) or (A.8-13) qmew,I = exhaust gas mass flow rate in mode i on a wet basis [kg/s] cgas,I = emission concentration in the raw exhaust gas in mode i, on a wet basis [ppm] or [per cent vol]
Annex 4B - Appendix A.8
A.8.2.1.2. Transient and ramped modal cycles tests The total mass per test of a gaseous emission mgas [g/test] shall be calculated by multiplication of the time aligned instantaneous concentrations and exhaust gas flows and integration over the test cycle according to the following equation: N mgas = ⋅ kh ⋅ k ⋅ ugas ⋅ ∑ ( qmew,i ⋅ cgas,i ) (A.8-4) f i =1
where: f = data sampling rate [Hz] kh = NOx correction factor [-], only to be applied for the NOx emission calculation k = 1 for cgasr,w,i in [ppm] and k = 10,000 for cgasr,w,i in [per cent vol] ugas = component specific factor [-] (see paragraph A.8.2.4.) N = number of measurements [-] qmew,i = instantaneous exhaust gas mass flow rate on a wet basis [kg/s] cgas,i = instantaneous emission concentration in the raw exhaust gas, on a wet basis [ppm] or [per cent vol] The following paragraphs show how the needed quantities (cgas,i, ugas and qmew,i) shall be calculated. A.8.2.2. Dry-to wet concentration conversion If the emissions are measured on a dry basis, the measured concentration cd on dry basis shall be converted to the concentration cw on a wet basis according to the following general equation:
cw = kw ⋅ cd (A.8-5)
where: kw = dry-to-wet conversion factor [-] cd = emission concentration on a dry basis [ppm] or [per cent vol] For complete combustion, the dry-to-wet conversion factor for raw exhaust gas is written as kw,a [-] and shall be calculated as follows: ⎛ q ⎞ ⎜ 1.2442 ⋅ H a + 111.19 ⋅ wH ⋅ mf,i ⎟ ⎜1 − q m ad, i ⎟ ⎜ qmf,i ⎟ ⎜ 773.4 + 1.2442 ⋅ H a + q ⋅ kf ⋅1000 ⎟ (A.8-6) kw,a = ⎝ ⎠ mad,i
⎛ pr ⎞ ⎜1 − ⎟ ⎝ pb ⎠
where: Ha = intake air humidity [g H2O/kg dry air] qmf,I = instantaneous fuel flow rate [kg/s] qmad,I = instantaneous dry intake air flow rate [kg/s]
Annex 4B - Appendix A.8
pr = water pressure after cooler [kPa] pb = total barometric pressure [kPa] wH = hydrogen content of the fuel [per cent mass] kf = combustion additional volume [m3/kg fuel] with: kf = 0.055594 ⋅ wH + 0.0080021 ⋅ wN + 0.0070046 ⋅ wO (A.8-7)
where: wH = hydrogen content of fuel [per cent mass] wN = nitrogen content of fuel [per cent mass] wO = oxygen content of fuel [per cent mass]
In the equation (A.8-6), the ratio pr pb may be assumed:
1 (A.8-8) = 1.008 ⎛ pr ⎞ ⎜1 − ⎟ ⎝ pb ⎠
For incomplete combustion (rich fuel air mixtures) and also for emission tests without direct air flow measurements, a second method of kw,a calculation is preferred: − kw1 1 + α ⋅ 0.005 ⋅ ( cCO2 + cCO ) kw,a = (A.8-9) p 1− r pb where: cCO2 = concentration of CO2 in the raw exhaust gas, on a dry basis [per cent vol] cCO = concentration of CO in the raw exhaust gas, on a dry basis [ppm] pr = water pressure after cooler [kPa] (see equation (A.8-9)) pb = total barometric pressure [kPa] (see equation (A.8-9)) α = molar to carbon hydrogen ratio [-] kw1 = intake air moisture [-] 1.608 ⋅ H a k w1 = (A.8-10) 1000 + 1.608 ⋅ H a
Annex 4B - Appendix A.8
A.8.2.3. NOx correction for humidity and temperature As the NOx emission depends on ambient air conditions, the NOx concentration shall be corrected for ambient air temperature and humidity with the factors kh [-] given in the following equation. This factor is valid for a humidity range between 0 and 25 g H2O/kg dry air. 15.698 ⋅ H a kh = + 0.832 (A.8-11) 1 000 where: Ha = humidity of the intake air [g H2O/kg dry air] A.8.2.4. Component specific factor u A.8.2.4.1. Tabulated values Applying some simplifications (assumption on the λ value and on intake air conditions as shown in the following table) to the equations of paragraph A.8.2.4.2. figures for ugas, can be calculated (see paragraph A.8.2.1.). The ugas values are given in Table A.8.1.
Table A.8.1 Raw exhaust gas u and component densities (the u figures are calculated for emission concentration expressed in ppm)
Gas NOx CO HC CO2 O2 CH4 ρgas [kg/m3] 2.053 1.250 0.621 1.9636 1.4277 0.716
Fuel ρe [kg/m3] Coefficient ugas at λ = 2, dry air, 273 K, 101.3 kPa
Diesel 1.2939 0.001587 0.000966 0.000479 0.001518 0.001103 0.000553
A.8.2.4.2. Calculated values The component specific factor, ugas,i, can be calculated by the density ratio of the component and the exhaust or alternatively by the corresponding ratio of molar masses:
ugas,i = M gas / ( M e,i ⋅1000 ) (A.8-12)
or
ugas,i = ρgas / ( ρe,i ⋅1000 ) (A.8-13)
where: Mgas = molar mass of the gas component [g/mol] Me,i = instantaneous molar mass of the wet raw exhaust gas [g/mol] ρgas = density of the gas component [kg/m3] ρe,I = instantaneous density of the wet raw exhaust gas [kg/m3]
Annex 4B - Appendix A.8
The molar mass of the exhaust, Me,i shall be derived for a general fuel composition CHαOεNδSγ under the assumption of complete combustion, as follows: qmf,i 1+ qmaw,i M e,i = α ε δ H a ⋅10−3 1 + + + qmf,i 4 2 2 2 × 1.00794 + 15.9994 M a ⋅ + qmaw,i 12.001 + 1.00794 ⋅ α + 15.9994 ⋅ ε + 14.0067 ⋅ δ + 32.0065 ⋅ γ 1 + H a ⋅10−3 (A.8-14) where: qmf,i = instantaneous fuel mass flow rate on wet basis [kg/s] qmaw,i = instantaneous intake air mass flow rate on wet basis [kg/s] α = molar hydrogen-to-carbon ratio [-] δ = molar nitrogen-to-carbon ratio [-] ε = molar oxygen-to-carbon ratio [-] γ = atomic sulphur-to-carbon ratio [-] Ha = intake air humidity [g H2O/kg dry air] Ma = dry intake air molecular mass = 28.965 g/mol The instantaneous raw exhaust density ρe,i [kg/m3] shall be derived as follows: 1000+H a + 1000 ⋅ ( qmf,i qmad,i ) ρe,i = (A.8-15) 773.4 +1.2434 ⋅ H a +kf ⋅1000 ⋅ ( qmf,i qmad,i )
where: qmf,I = instantaneous fuel mass flow rate [kg/s] qmad,I = instantaneous dry intake air mass flow rate [kg/s] Ha = intake air humidity [g H2O/kg dry air] kf = combustion additional volume [m3/kg fuel] (see equation A.8-7) A.8.2.5. Mass flow rate of the exhaust gas A.8.2.5.1. Air and fuel measurement method The method involves measurement of the air flow and the fuel flow with suitable flow-meters. The calculation of the instantaneous exhaust gas flow qmew,i [kg/s] shall be as follows:
qmew,i = qmaw,i + qmf,i (A.8-16)
where: qmaw,i = instantaneous intake air mass flow rate [kg/s] qmf,i = instantaneous fuel mass flow rate [kg/s]
Annex 4B - Appendix A.8
A.8.2.5.2. Tracer measurement method This involves measurement of the concentration of a tracer gas in the exhaust. The calculation of the instantaneous exhaust gas flow qmew,i [kg/s] shall be as follows: qVt ⋅ ρe (A.8-17) qmew,i = 10 ⋅ ( cmix,i − cb ) −6
where: qVt = tracer gas flow rate [m³/s] cmix,I = instantaneous concentration of the tracer gas after mixing [ppm] ρe = density of the raw exhaust gas [kg/m³] cb = background concentration of the tracer gas in the intake air [ppm] The background concentration of the tracer gas cb may be determined by averaging the background concentration measured immediately before the test run and after the test run. When the background concentration is less than 1 per cent of the concentration of the tracer gas after mixing cmix,i at maximum exhaust flow, the background concentration may be neglected. A.8.2.5.3. Air flow and air to fuel ratio measurement method This involves exhaust mass calculation from the air flow and the air to fuel ratio. The calculation of the instantaneous exhaust gas mass flow qmew,i [kg/s] is as follows:
⎛ 1 ⎞ qmew,i = qmaw,i ⋅ ⎜ 1 + ⎟ (A.8-18) ⎝ A/Fst ⋅ λi ⎠ with: ⎛ α ε ⎞ 138.0 ⋅ ⎜1 + − + γ ⎟ A / Fst = ⎝ 4 2 ⎠ (A.8-19) 12.011 + 1.00794 ⋅ α + 15.9994 ⋅ ε + 14.0067 ⋅ δ + 32.065 ⋅ γ
⎛ 2 ⋅ cCOd ⋅10−4 ⎞ ⎜ 1− ⎟ ⎛ cCOd ⋅10 −4 ⎞ α 3.5 ⋅ c ε δ ⎜100 − − cHCw ⋅10−4 ⎟ + ⎜ ⋅ CO2d −4 ( − − ⎟ ⋅ cCO2d + cCOd ⋅10−4 ) ⎝ 2 ⎠ ⎜ 4 1 + cCOd ⋅10 2 2⎟ ⎜ 3.5 ⋅ c ⎟ λi = ⎝ CO2d ⎠ ⎛ α ε ⎞ ⎝ 4 2 ( 4.764 ⋅ ⎜1 + − + γ ⎟ ⋅ cCO2d + cCOd ⋅10 + cHCw ⋅10−4 ⎠ −4 ) (A.8-20)
where: qmaw,I = wet intake air mass flow rate [kg/s] A/Fst = stoichiometric air-to-fuel ratio [-] λI = instantaneous excess air ratio [-] cCod = concentration of CO in the raw exhaust gas on a dry basis [ppm]
Annex 4B - Appendix A.8
cCO2d = concentration of CO2 in the raw exhaust gas on a dry basis [per cent] cHCw = concentration of HC in the raw exhaust gas on a wet basis [ppm C1] α = molar hydrogen-to-carbon ratio [-] δ = molar nitrogen-to-carbon ratio [-] ε = molar oxygen-to-carbon ratio [-] γ = atomic sulphur-to-carbon ratio [-] A.8.2.5.4. Carbon balance method, 1 step-procedure The following 1-step formula can be used for the calculation of the wet exhaust mass flow rate qmew,i [kg/s]: ⎡ 1.4 ⋅ wC2 ⎛ H ⎞ ⎤ (A.8-21) qmew,i = qmf,i ⋅ ⎢ ⎜ 1 + a ⎟ + 1⎥ ⎢⎣ (1.0828 ⋅ wC + kfd ⋅ f c ) f c ⎝ 1000 ⎠ ⎥⎦
with the carbon factor fc [-] given by: cCOd c f c = 0.5441⋅ ( cCO2d − cCO2d,a ) + + HCw (A.8-22) 18522 17355 where: qmf,i = instantaneous fuel mass flow rate [kg/s] wC = carbon content of fuel [per cent mass] Ha = intake air humidity [g H2O/kg dry air] kfd = combustion additional volume on a dry basis [m3/kg fuel] cCO2d = dry CO2 concentration in the raw exhaust [per cent] cCO2d,a = dry CO2 concentration in the ambient air [per cent] cCod = dry CO concentration in the raw exhaust [ppm] cHCw = wet HC concentration in the raw exhaust [ppm] and factor kfd [m3/kg fuel] that is calculated on a dry basis by subtracting the water formed by combustion from kf : kfd = kf − 0.11118 ⋅ wH (A.8-23)
where: kf = fuel specific factor of equation (A.8-7) [m3/kg fuel] wH = hydrogen content of fuel [per cent mass]
Annex 4B - Appendix A.8
A.8.3. Diluted gaseous emissions A.8.3.1. Mass of the gaseous emissions A.8.3.1.1. Full flow dilution measurement (CVS) The exhaust mass flow rate shall be measured with a constant volume sampling (CVS) system, which may use a positive displacement pump (PDP), a critical flow venturi (CFV) or a subsonic venturi (SSV). For systems with constant mass flow (i.e. with heat exchanger), the mass of the pollutants mgas [g/test] shall be determined from the following equation:
mgas = kh ⋅ k ⋅ ugas ⋅ cgas ⋅ med (A.8-24)
where: ugas = ratio between density of exhaust component and density of air, as given in Table A.8.2 or calculated with equation (A.8-35) [-] cgas = mean background corrected concentration of the component on a wet basis [ppm] or [per cent vol] respectively kh = NOx correction factor [-], only to be applied for the NOx emission calculation k = 1 for cgasr,w,i in [ppm], k = 10,000 for cgasr,w,i in [per cent vol] med = total diluted exhaust gas mass over the cycle [kg/test] For systems with flow compensation (without heat exchanger), the mass of the pollutants mgas [g/test] shall be determined by calculation of the instantaneous mass emissions, by integration and by background correction according to the following equation: ⎧⎪ N ⎡⎛ ⎛ 1⎞ ⎞ ⎤ ⎫⎪ mgas = kh ⋅ k ⋅ ⎨∑ ⎣⎡( med,i ⋅ ce ⋅ ugas ) ⎦⎤ − ⎢⎜ med ⋅ cd ⋅ ⎜1 − ⎟ ⋅ ugas ⎟ ⎥ ⎬ (A.8-25) ⎪⎩ i =1 ⎣⎝ ⎝ D⎠ ⎠ ⎦ ⎪⎭ where: ce = emission concentration in the diluted exhaust gas, on a wet basis [ppm] or [per cent vol] cd = emission concentration in the dilution air, on a wet basis [ppm] or [per cent vol] med,i = mass of the diluted exhaust gas during time interval i [kg] med = total mass of diluted exhaust gas over the cycle [kg] ugas = tabulated value from Table A.8.2 [-] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-] kh = NOx correction factor [-], only to be applied for the NOx emission calculation k = 1 for c in [ppm], k = 10,000 for c in [per cent vol]
Annex 4B - Appendix A.8
The concentrations cgas, ce and cd can be either values measured in a batch sample (bag, but not allowed for NOx and HC) or be averaged by integration from continuous measurements. Also med,i has to be averaged by integration over the test cycle. The following equations show how the needed quantities (ce, ugas and med) shall be calculated. A.8.3.2. Dry-to wet concentration conversion All concentrations in paragraph A.8.3.2. shall be converted using equation (A.8-5) ( cw = k w ⋅ cd ).
A.8.3.2.1. Diluted exhaust gas All concentrations measured dry shall be converted to wet concentrations by one of the following two equations applied to equation: ⎡ ⎛ α ⋅ cCO2w ⎞ ⎤ (A.8-26) kw,e = ⎢ ⎜1 − ⎟ − kw2 ⎥ ⋅1.008 ⎣⎝ 200 ⎠ ⎦ or ⎛ ⎞ ⎜ ( 1 − k w2 ) ⎟ (A.8-27) k w,e = ⎜ ⎟ ⋅1.008 ⎜ 1 + α ⋅ cCO2d ⎟ ⎝ 200 ⎠ where: kw,e = dry-to-wet conversion factor for the diluted exhaust gas [-] α = molar hydrogen to carbon ratio of the fuel [-] cCO2w = concentration of CO2 in the diluted exhaust gas on a wet basis [per cent vol] cCO2d = concentration of CO2 in the diluted exhaust gas on a dry basis [per cent vol] The dry to wet correction factor kw2 takes into consideration the water content of both intake air and dilution air: ⎡ ⎛ 1⎞ ⎛ 1 ⎞⎤ 1.608 ⋅ ⎢ H d ⋅ ⎜1 − ⎟ + H a ⋅ ⎜ ⎟ ⎥ ⎣ ⎝ D⎠ ⎝ D ⎠⎦ (A.8-28) kw2 = ⎧ ⎡ ⎛ 1⎞ ⎛ 1 ⎞⎤ ⎫ 1000 + ⎨1.608 ⋅ ⎢ H d ⋅ ⎜ 1 − ⎟ + H a ⋅ ⎜ ⎟ ⎥ ⎬ ⎩ ⎣ ⎝ D⎠ ⎝ D ⎠⎦ ⎭ where: Ha = intake air humidity [g H2O/kg dry air] Hd = dilution air humidity [g H2O/kg dry air] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-]
Annex 4B - Appendix A.8
A.8.3.2.2. Dilution factor The dilution factor D [-] (which is necessary for the background correction and the kw2 calculation) shall be calculated as follows: FS D= (A.8-29) cCO2,e + ( cHC,e + cCO,e ) ⋅10−4
where: FS = stoichiometric factor [-] cCO2,e = concentration of CO2 in the diluted exhaust gas on a wet basis [per cent vol] cHC,e = concentration of HC in the diluted exhaust gas on a wet basis [ppm C1] cCO,e = concentration of CO in the diluted exhaust gas on a wet basis [ppm] The stoichiometric factor shall be calculated as follows: 1 (A.8-30) FS =100 ⋅ α ⎛ α⎞ 1 + + 3.76 ⋅ ⎜1 + ⎟ 2 ⎝ 4⎠ where: α = molar hydrogen to carbon ratio in the fuel [-] Alternatively, if the fuel composition is not known, the following stoichiometric factors may be used: FS (diesel) = 13.4 If a direct measurement is made of the exhaust gas flow, the dilution factor D [- ] may be calculated as follows: q D = VCVS (A.8-31) qVew where: qVCVS = volumetric flow rate of diluted exhaust gas [m3/s] qVew = volumetric flow rate of raw exhaust gas [m3/s] A.8.3.2.3. Dilution air kw,d = (1 − kw3 ) ⋅1.008 (A.8-32)
with 1.608 ⋅ H d (A.8-33) k w3 = 1000 + 1.608 ⋅ H d
where: Hd = dilution air humidity [g H2O/kg dry air]
Annex 4B - Appendix A.8
A.8.3.2.4. Determination of the background corrected concentration The average background concentration of the gaseous pollutants in the dilution air shall be subtracted from measured concentrations to get the net concentrations of the pollutants. The average values of the background concentrations can be determined by the sample bag method or by continuous measurement with integration. The following equation shall be used:
⎛ 1⎞ cgas = cgas,e − cd ⋅ ⎜1- ⎟ (A.8-34) ⎝ D⎠ where: cgas = net concentration of the gaseous pollutant [ppm] or [per cent vol] cgas,e = emission concentration in the diluted exhaust gas, on a wet basis [ppm] or [per cent vol] cd = emission concentration in the dilution air, on a wet basis [ppm] or [per cent vol] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-] A.8.3.3. Component specific factor u The component specific factor ugas of diluted gas can either be calculated by the following equation or be taken from Table A.8.2; in Table A.8.2 the density of the diluted exhaust gas has been assumed equal to air density. M gas M gas (A.8-35) u= = M d,w ⋅1000 ⎡ ⎛ 1⎞ ⎛ 1 ⎞⎤ ⎢ M da,w ⋅ ⎜1 − D ⎟ + M r,w ⋅ ⎜ D ⎟ ⎥ ⋅1000 ⎣ ⎝ ⎠ ⎝ ⎠⎦ where: Mgas = molar mass of the gas component [g/mol] Md,w = molar mass of diluted exhaust gas [g/mol] Mda,w = molar mass of dilution air [g/mol] Mr,w = molar mass of raw exhaust gas [g/mol] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-]
Table A.8.2 Diluted exhaust gas u values and component densities (the u figures are calculated for emission concentration expressed in ppm)
Gas NOx CO HC CO2 O2 CH4 ρgas [kg/m3] 2.053 1.250 0.621 1.9636 1.4277 0.716
Fuel ρe [kg/m3] Coefficient ugas at λ = 2, dry air, 273 K, 101.3 kPa
Diesel 1.293 0.001588 0.000967 0.000480 0.001519 0.00110 0.000553
Annex 4B - Appendix A.8
A.8.3.4. Exhaust gas mass flow calculation A.8.3.4.1. PDP-CVS system The calculation of the mass of the diluted exhaust [kg/test] over the cycle is as follows, if the temperature of the diluted exhaust med is kept within ±6 K over the cycle by using a heat exchanger: pp273.15 med = 1.293 ⋅V0 ⋅ nP ⋅ ⋅ (A.8-36) 101.325 T where: V0 = volume of gas pumped per revolution under test conditions [m³/rev] nP = total revolutions of pump per test [rev/test] pp = absolute pressure at pump inlet [kPa]
T = average temperature of the diluted exhaust gas at pump inlet [K] 1.293 kg/m3 = air density at 273.15 K and 101.325 kPa If a system with flow compensation is used (i.e. without heat exchanger), the mass of the diluted exhaust gas med,i [kg] during the time interval shall be calculated as follows: pp 273.15 med,i = 1.293 ⋅V0 ⋅ nP,i ⋅ ⋅ (A.8-37) 101.325 T where: V0 = volume of gas pumped per revolution under test conditions [m³/rev] pp = absolute pressure at pump inlet [kPa] nP,i = total revolutions of pump per time interval i [rev/Δt]
T = average temperature of the diluted exhaust gas at pump inlet [K] 1.293 kg/m3 = air density at 273.15 K and 101.325 kPa A.8.3.4.2. CFV-CVS system The calculation of the mass flow over the cycle med [g/test] is as follows, if the temperature of the diluted exhaust is kept within ±11 K over the cycle by using a heat exchanger: 1.293 ⋅ t ⋅ K V ⋅ pp med = (A.8-38) T 0.5
Annex 4B - Appendix A.8
where: t = cycle time [s] KV = calibration coefficient of the critical flow venturi for standard conditions ⎡ ⎣ ( K ⋅ m ⋅ s ) /kg ⎤⎦
pp = absolute pressure at venturi inlet [kPa] T = absolute temperature at venturi inlet [K] 1.293 kg/m3 = air density [ ] at 273.15 K and 101.325 kPa If a system with flow compensation is used (i.e. without heat exchanger), the mass of the diluted exhaust gas med,i [kg] during the time interval shall be calculated as follows: 1.293 ⋅ Δti ⋅ K V ⋅ pp med,i = (A.8-39) T 0.5 where: Δti = time interval of the test [s] KV = calibration coefficient of the critical flow venturi for
⎣ ( standard conditions ⎡ K ⋅ m 4 ⋅ s /kg ⎤) ⎦ pp = absolute pressure at venturi inlet [kPa] T = absolute temperature at venturi inlet [K] 1.293 kg/m = air density at 273.15 K and 101.325 kPa A.8.3.4.3. SSV-CVS system The calculation of the diluted exhaust gas mass over the cycle med [kg/test] shall be as follows, if the temperature of the diluted exhaust is kept within ±11K over the cycle by using a heat exchanger:
med = 1.293 ⋅ qVSSV ⋅ Δt (A.8-40)
where: 1.293 kg/m3 = air density at 273.15 K and 101.325 kPa Δt = cycle time [s] qVSSV = air flow rate at standard conditions (101.325 kPa, 273.15 K) [m3/s] with
A0 2 ⎡ 1 1.4286 ⎛ 1 ⎞⎤ qVSSV = d V Cd pp ⎢ (rp − rp1.7143 ⋅ ⎜ ) ⎜ 1 − rD rp 4 1.4286 ⎟⎟ ⎥ (A.8-41) ⎢⎣ Tin ⎝ ⎠ ⎥⎦
Annex 4B - Appendix A.8
where: A0 = collection of constants and units conversions = 0.0056940 ⎡ 3 1 ⎤ ⎢m ⋅K ⋅ 1 ⎥
⎢ min kPa mm 2 ⎥ ⎢⎣ ⎥⎦
dV = diameter of the SSV throat [mm] Cd = discharge coefficient of the SSV [-] pp = absolute pressure at venturi inlet [kPa] Tin = temperature at the venturi inlet [K] rp = ratio of the SSV throat to inlet absolute static pressure, ⎛ Δp ⎞ ⎜1 − ⎟ [-] ⎝ pa ⎠
rD = ratio of the SSV throat diameter to the inlet pipe inner d diameter [-] D If a system with flow compensation is used (i.e. without heat exchanger), the mass of the diluted exhaust gas med,i [kg] during the time interval shall be calculated as follows: med,i = 1.293 ⋅ qVSSV ⋅ Δti (A.8-42)
where: 1.293 kg/m3 = air density at 273.15 K and 101.325 kPa Δti = time interval [s] qVSSV = volumetric flow rate of the SSV [m3/s] A.8.3.5. Calculation of particulates emission A.8.3.5.1. Transient and ramped modal cycles The particulate mass shall be calculated after buoyancy correction of the particulate sample mass according to paragraph 8.1.12.2.5. A.8.3.5.1.1. Partial flow dilution system The calculation for double dilution system is shown in paragraph A.8.3.5.1.2. A.8.3.5.1.1.1. Calculation based on sample ratio The particulate emission over the cycle mPM [g] shall be calculated with the following equation: mf mPM = (A.8-43) rs ⋅1000 where: mf = particulate mass sampled over the cycle [mg] rs = average sample ratio over the test cycle [-]
Annex 4B - Appendix A.8
with: mse msep rs = ⋅ (A.8-44) mew msed where: mse = sample mass of raw exhaust over the cycle [kg] mew = total mass of raw exhaust over the cycle [kg] msep = mass of diluted exhaust gas passing the particulate collection filters [kg] msed = mass of diluted exhaust gas passing the dilution tunnel [kg] In case of the total sampling type system, msep and msed are identical. A.8.3.5.1.1.2. Calculation based on dilution ratio The particulate emission over the cycle mPM [g] shall be calculated with the following equation: mf medf (A.8-45) mPM = ⋅ msep 1000
where: mf = particulate mass sampled over the cycle [mg] msep = mass of diluted exhaust gas passing the particulate collection filters [kg] medf = mass of equivalent diluted exhaust gas over the cycle [kg] The total mass of equivalent diluted exhaust gas mass over the cycle medf [kg] shall be determined as follows:
1 N medf = ⋅ ∑ qmedf,i (A.8-46) f i =1 qmedf,i = qmew,i ⋅ rd,i (A.8-47)
qmdew,i rd,i = (A.8-48) qmdew,i − qmdw,i where: qmedf,i = instantaneous equivalent diluted exhaust mass flow rate [kg/s] qmew,i = instantaneous exhaust mass flow rate on a wet basis [kg/s] rd,I = instantaneous dilution ratio [-] qmdew,i = instantaneous diluted exhaust mass flow rate on a wet basis [kg/s] qmdw,i = instantaneous dilution air mass flow rate [kg/s] f = data sampling rate [Hz] N = number of measurements [-]
Annex 4B - Appendix A.8
A.8.3.5.1.2. Full flow dilution system The mass emission shall be calculated as follows: mf med (A.8-49) mPM = ⋅ msep 1000
where: mf = particulate mass sampled over the cycle [mg] msep = mass of diluted exhaust gas passing the particulate collection filters [kg] med = mass of diluted exhaust gas over the cycle [kg] with
msep = mset − mssd (A.8-50)
where: mset = mass of double diluted exhaust gas through particulate filter [kg] mssd = mass of secondary dilution air [kg] A.8.3.5.1.3. Background correction The particulate mass mPM,c [g] may be background corrected as follows: ⎧⎪ m ⎡m ⎛ 1 ⎞ ⎤ ⎫⎪ m mPM,c = ⎨ f − ⎢ b ⋅ ⎜ 1 − ⎟ ⎥ ⎬ ⋅ ed (A.8-51) ⎪⎩ msep ⎣ msd ⎝ D ⎠ ⎦ ⎪⎭ 1000
where: mf = particulate mass sampled over the cycle [mg] msep = mass of diluted exhaust gas passing the particulate collection filters [kg] msd = mass of dilution air sampled by background particulate sampler [kg] mb = mass of collected background particulates of dilution air [mg] med = mass of diluted exhaust gas over the cycle [kg] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-] A.8.3.5.2. Calculation for steady-state discrete-mode cycles A.8.3.5.2.1. Dilution system All calculations shall be based upon the average values of the individual modes i during the sampling period.
(a) For partial-flow dilution, the equivalent mass flow of diluted exhaust gas shall be determined by means of the system with flow measurement shown in Figure 9.2:
qmedf = qmew ⋅ rd (A.8-52)
Annex 4B - Appendix A.8
qmdew rd = (A.8-53) qmdew − qmdw where: qmedf = equivalent diluted exhaust mass flow rate [kg/s] qmew = exhaust mass flow rate on a wet basis [kg/s] rd = dilution ratio [-] qmdew = diluted exhaust mass flow rate on a wet basis [kg/s] qmdw = dilution air mass flow rate [kg/s]
(b) For full-flow dilution systems qmdew is used as qmedf. A.8.3.5.2.2. Calculation of the particulate mass flow rate The particulate emission flow rate over the cycle qmPM [g/h] shall be calculated as follows:
(a) For the single-filter method mf 3600 qmPM = ⋅ qmedf ⋅ (A.8-54) msep 1000 N qmedf = ∑ qmedfi ⋅ WFi (A.8-55) i =1
N msep = ∑ msepi (A.8-56) i =1
where: qmPM = particulate mass flow rate [g/h] mf = particulate mass sampled over the cycle [mg]
qmedf = average equivalent diluted exhaust gas mass flow rate on wet basis [kg/s] qmedfi = equivalent diluted exhaust gas mass flow rate on wet basis at mode i [kg/s] WFi = weighing factor for the mode i [-] msep = mass of diluted exhaust gas passing the particulate collection filters [kg] msepi = mass of diluted exhaust sample passed through the particulate sampling filter at mode i [kg] N = number of measurements [-]
(b) For the multiple-filter method mfi 3600 qmPMi = ⋅q ⋅ (A.8-57) m e d f
i msepi 1000
Annex 4B - Appendix A.8
where: qmPMi = particulate mass flow rate for the mode i [g/h] mfi = particulate sample mass collected at mode i [mg] qmedfi = equivalent diluted exhaust gas mass flow rate on wet basis at mode i [kg/s] msepi = mass of diluted exhaust sample passed through the particulate sampling filter at mode i [kg] The PM mass is determined over the test cycle by summation of the average values of the individual modes i during the sampling period. The particulate mass flow rate qmPM [g/h] or qmPMi [g/h] may be background corrected as follows:
(a) For the single-filter method
⎧⎪ m ⎡m N ⎛ 1 ⎞ ⎤ ⎫⎪ 3600 qmPM = ⎨ f − ⎢ f,d ⋅ ∑ ⎜1 − ⎟ ⋅ WFi ⎥ ⎬ ⋅ qmedf (A.8-58) m ⎢ m ⎪⎩ sep ⎣ d i =1 ⎝ Di ⎠ ⎥ ⎦ ⎪⎭ 1000
where: qmPM = particulate mass flow rate [g/h] mf = particulate sample mass collected [mg] msep = mass of diluted exhaust sample passed through the particulate sampling filter [kg] mf,d = particulate sample mass of the dilution air collected [mg] md = mass of the dilution air sample passed through the particulate sampling filters [kg] Di = dilution factor at mode i (see equation (A.8-29) of paragraph A.8.3.2.2.) [-] WFi = weighing factor for the mode i [-]
qmedf = average equivalent diluted exhaust gas mass flow rate on wet basis [kg/s]
(b) For the multiple-filter method
⎧⎪ m ⎡m ⎛ 1 ⎞ ⎤ ⎫⎪ 3600 qmPMi = ⎨ fi − ⎢ f,d ⋅ ⎜1 − ⎟ ⎥ ⎬ ⋅ qmedfi (A.8-59) ⎪⎩ msepi ⎣ md ⎝ D ⎠ ⎦ ⎪⎭ 1000
where: qmPM = particulate mass flow rate [g/h] mfi = particulate sample mass collected at mode i [mg] mf,d = particulate sample mass of the dilution air collected [mg] qmedfi = equivalent diluted exhaust gas mass flow rate on wet basis at mode i [kg/h]
Annex 4B - Appendix A.8
msepi = mass of diluted exhaust sample passed through the particulate sampling filter at mode i [kg] md = mass of the dilution air sample passed through the particulate sampling filters [kg] D = dilution factor (see equation (A.8-29) of paragraph A.8.3.2.2.) [-]
qmedf = average equivalent diluted exhaust gas mass flow rate on wet basis [kg/s]
If more than one measurement is made, mf,d md shall be replaced with
mf,d md . A.8.4. Cycle work and specific emissions A.8.4.1. Gaseous emissions A.8.4.1.1. Transient and ramped modal cycles Reference is made to paragraphs A.8.2.1. and A.8.3.1. for raw and diluted exhaust respectively. The resulting values for power P [kW] shall be integrated over a test interval. The total work Wact [kWh] is calculated as follows: N 1 1 1 2⋅π N Wact = ∑ Pi ⋅ Δti = ⋅ ⋅ 3 ∑ ( ni ⋅ Ti ) (A.8-60) i =1 f 3600 10 60 i =1 where: Pi = instantaneous engine power [kW] ni = instantaneous engine speed [min-1] Ti = instantaneous engine torque [Nm] Wact = actual cycle work [kWh] f = data sampling rate [Hz] N = number of measurements [-] The specific emissions egas [g/kWh] shall be calculated in the following ways depending on the type of test cycle.
mgas egas = (A.8-61) Wact where: mgas = total mass of emission [g/test] Wact = cycle work [kWh] In case of the transient cycle, the final test result egas [g/kWh] shall be a weighted average from cold start test and hot start test by using:
egas = ( 0.1⋅ mcold ) + ( 0.9 ⋅ mhot ) (A.8-62) ( 0.1⋅W act,cold ) + ( 0.9 ⋅W act,hot )
Annex 4B - Appendix A.8
In case of an infrequent (periodic) exhaust regeneration (paragraph 6.6.2.), the specific emissions shall be corrected with the multiplicative adjustment factor kr (equation (6-4)) or with the two separate pairs of adjustment additive factors kUr (upward factor of equation (6-5)) and kDr (downward factor of equation (6-6)). A.8.4.1.2. Steady-state discrete-mode cycle The specific emissions egas [g/kWh] are calculated as follows: N mode .
∑ (q mgasi ⋅ WFi ) (A.8-63) egas = i =1 N mode
∑ ( P ⋅WF ) i =1 i i
where: qmgas,i = mean emission mass flow rate for the mode i [g/h]
Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3 and 7.7.1.2.) WFi = weighing factor for the mode i [-] A.8.4.2. Particulate emissions A.8.4.2.1. Transient and ramped modal cycles The particulate specific emissions shall be calculated with equation (A.8-61) where egas [g/kWh] and mgas [g/test] are substituted by ePM [g/kWh] and mPM [g/test] respectively: mPM (A.8-64) ePM = Wact where: mPM = total mass of particulates emission, calculated according to paragraph A.8.3.5. [g/test] Wact = cycle work [kWh] The emissions on the transient composite cycle (i.e. cold phase and hot phase) shall be calculated as shown in paragraph A.8.4.1. A.8.4.2.2. Steady state discrete-mode cycle The particulate specific emission ePM [g/kWh] shall be calculated in the following way:
(a) For the single-filter method qm PM (A.8-65) ePM = N
∑ ( P ⋅ WF ) i =1 i i
Annex 4B - Appendix A.8
where: Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3. and 7.7.1.2.) WFi = weighing factor for the mode i [-] qmPM = particulate mass flow rate [g/h]
(b) For the multiple-filter method N
∑(q m PM i ⋅ WFi ) (A.8-66) ePM = i =1 N
∑ ( P ⋅ WF ) i =1 i i
where: Pi = engine power for the mode i [kW] with Pi = Pmaxi + Pauxi (see paragraphs 6.3. and 7.7.1.2.) WFi = weighing factor for the mode i [-] qmPMi = particulate mass flow rate at mode i [g/h] For the single-filter method, the effective weighing factor, WFei, for each mode shall be calculated in the following way:
msepi ⋅ qmedf WFei = (A.8-67) msep ⋅ qmedfi where: msepi = mass of the diluted exhaust sample passed through the particulate sampling filters at mode i [kg]
qmedf = average equivalent diluted exhaust gas mass flow rate [kg/s]
qmedfi = equivalent diluted exhaust gas mass flow rate at mode i [kg/s] msep = mass of the diluted exhaust sample passed through the particulate sampling filters [kg] The value of the effective weighing factors shall be within ±0.005 (absolute value) of the weighing factors listed in Annex 5.
Annex 4B - Appendix A.8.1
Annex 4B - Appendix A.8.1
Diluted exhaust flow (CVS) calibration A.8.5. Calibration of CVS system The CVS system shall be calibrated by using an accurate flow-meter and a restricting device. The flow through the system shall be measured at different restriction settings, and the control parameters of the system shall be measured and related to the flow. Various types of flow-meters may be used, e.g. calibrated venturi, calibrated laminar flow-meter, calibrated turbine meter. A.8.5.1. Positive displacement pump (PDP) All the parameters related to the pump shall be simultaneously measured along with the parameters related to a calibration venturi which is connected in series with the pump. The calculated flow rate (in m3/s at pump inlet, absolute pressure and temperature) shall be plotted versus a correlation function which is the value of a specific combination of pump parameters. The linear equation which relates the pump flow and the correlation function shall be determined. If a CVS has a multiple speed drive, the calibration shall be performed for each range used. Temperature stability shall be maintained during calibration. Leaks in all the connections and ducting between the calibration venturi and the CVS pump shall be maintained lower than 0.3 per cent of the lowest flow point (highest restriction and lowest PDP speed point). The airflow rate (qVCVS) at each restriction setting (minimum 6 settings) shall be calculated in standard m3/s from the flow-meter data using the manufacturer's prescribed method. The airflow rate shall then be converted to pump flow (V0) in m3/rev at absolute pump inlet temperature and pressure as follows: qVCVS T 101.325 V0 = ⋅ ⋅ (A.8-68) n 273.15 pp where: qVCVS = airflow rate at standard conditions (101.325 kPa, 273.15 K) [m3/s] T = temperature at pump inlet [K] pp = absolute pressure at pump inlet [kPa] n = pump speed [rev/s] To account for the interaction of pressure variations at the pump and the pump slip rate, the correlation function (X0) [s/rev] between pump speed, pressure differential from pump inlet to pump outlet and absolute pump outlet pressure shall be calculated as follows:
Annex 4B - Appendix A.8.1
1 Δpp X0 = ⋅ (A.8-69) n pp where: Δpp = pressure differential from pump inlet to pump outlet [kPa] pp = absolute outlet pressure at pump outlet [kPa] n = pump speed [rev/s] A linear least-square fit shall be performed to generate the calibration equation as follows:
V0 = D0 − m ⋅ X 0 (A.8-70)
with D0 [m3/rev] and m [m3/s], intercept and slope respectively, describing the regression line. For a CVS system with multiple speeds, the calibration curves generated for the different pump flow ranges shall be approximately parallel, and the intercept values (D0) shall increase as the pump flow range decreases. The calculated values from the equation shall be within ±0.5 per cent of the measured value of V0. Values of m will vary from one pump to another. Particulate influx over time will cause the pump slip to decrease, as reflected by lower values for m. Therefore, calibration shall be performed at pump start-up, after major maintenance, and if the total system verification indicates a change of the slip rate. A.8.5.2. Critical flow venturi (CFV) Calibration of the CFV is based upon the flow equation for a critical venturi. Gas flow is a function of venturi inlet pressure and temperature. To determine the range of critical flow, KV shall be plotted as a function of venturi inlet pressure. For critical (choked) flow, KV will have a relatively constant value. As pressure decreases (vacuum increases), the venturi becomes unchoked and KV decreases, which indicates that the CFV is operated outside the permissible range. The airflow rate (qVCVS) at each restriction setting (minimum 8 settings) shall be calculated in standard m3/s from the flow-meter data using the manufacturer's ( ) prescribed method. The calibration coefficient KV ⎡ K ⋅ m 4 ⋅ s /kg ⎤ shall be ⎣ ⎦ calculated from the calibration data for each setting as follows:
qVCVS ⋅ T KV = (A.8-71) pp where: qVSSV = air flow rate at standard conditions (101.325 kPa, 273.15 K) [m3/s] T = temperature at the venturi inlet [K] pp = absolute pressure at venturi inlet [kPa]
Annex 4B - Appendix A.8.1
The average KV and the standard deviation shall be calculated. The standard deviation shall not exceed ±0.3 per cent of the average KV. A.8.5.3. Subsonic venturi (SSV) Calibration of the SSV is based upon the flow equation for a subsonic venturi. Gas flow is a function of inlet pressure and temperature, pressure drop between the SSV inlet and throat, as shown in equation (A.8-41). The airflow rate (qVSSV) at each restriction setting (minimum 16 settings) shall be calculated in standard m3/s from the flow-meter data using the manufacturer's prescribed method. The discharge coefficient shall be calculated from the calibration data for each setting as follows: qVSSV Cd = A0 ⎡ 1 ⎛ 1 ⎞⎤ ⋅ d V 2 ⋅ pp ⋅ ⎢ ( ) rp1.4286 − rp1.7143 ⎜ ⎜ 1 − rD 4 ⋅ rp1.4286 ⎟⎟ ⎥⎥ ⎢⎣ Tin,V ⎝ ⎠⎦
(A.8-72) where: A0 = collection of constants and units conversions = 0.0056940 ⎡ 3 1 ⎤ ⎢m ⋅K ⋅ 1 ⎥
⎢ min kPa mm 2 ⎥ ⎢⎣ ⎥⎦
qVSSV = air flow rate at standard conditions (101.325 kPa, 273.15 K) [m3/s] Tin,V = temperature at the venturi inlet [K] dV = diameter of the SSV throat [mm] rp = ratio of the SSV throat to inlet absolute static pressure = 1 − Δp pp [-] rD = ratio of the SSV throat diameter, dV, to the inlet pipe inner diameter D [-] To determine the range of subsonic flow, Cd shall be plotted as a function of Reynolds number Re, at the SSV throat. The Re at the SSV throat shall be calculated with the following equation: qVSSV (A.8-73) Re = A1 ⋅ 60 ⋅ dV ⋅ μ with b × T 1.5 μ= (A.8-74) S+T
Annex 4B - Appendix A.8.1 where: A1 = collection of constants and units conversions = 27.43831 ⎡ kg min mm ⎤ ⎢ 3⋅ s ⋅ m ⎥ ⎣m ⎦ qVSSV = air flow rate at standard conditions (101.325 kPa, 273.15 K) [m3/s] dV = diameter of the SSV throat [mm] μ = absolute or dynamic viscosity of the gas [kg/(m·s)] b = 1.458 x 106 (empirical constant) [kg/(m·s·K0.5)] S = 110.4 (empirical constant) [K] Because qVSSV is an input to the Re equation, the calculations shall be started with an initial guess for qVSSV or Cd of the calibration venturi, and repeated until qVSSV converges. The convergence method shall be accurate to 0.1 per cent of point or better. For a minimum of sixteen points in the region of subsonic flow, the calculated values of Cd from the resulting calibration curve fit equation shall be within ±0.5 per cent of the measured Cd for each calibration point.
Annex 4B - Appendix A.8.2
Annex 4B - Appendix A.8.2
Drift correction A.8.6. Calculations in this appendix are performed as described in Appendix A.7.2 to Appendix A.7 to Annex 4B.
2ci − ( cprezero + cpostzero ) cidriftcor = crefzero + ( crefspan − crefzero ) (A.8-75) (c prespan + cpostspan ) − ( cprezero + cpostzero ) where: cidriftcor = concentration corrected for drift [ppm] crefzero = reference concentration of the zero gas, which is usually zero unless known to be otherwise [ppm] crefspan = reference concentration of the span gas [ppm] cprespan = pre-test interval gas analyser response to the span gas concentration [ppm] cpostspan = post-test interval gas analyser response to the span gas concentration [ppm] ci or c = concentration recorded, i.e. measured, during test, before drift correction [ppm] cprezero = pre-test interval gas analyser response to the zero gas concentration [ppm] cpostzero = post-test interval gas analyser response to the zero gas concentration [ppm]
Annex 5 — Test cycles
1.Test cycles
Steady-state discrete-mode testing
(a) For variable-speed engines, the following 8-mode cycle 1 shall be followed in dynamometer operation on the test engine:
Mode Number Engine Speed Torque [per cent] Weighing Factor
1 Rated 100 0.15
2 Rated 75 0.15
3 Rated 50 0.15
4 Rated 10 0.10
5 Intermediate 100 0.10
6 Intermediate 75 0.10
7 Intermediate 50 0.10
8 Idle --- 0.15
(b) For constant-speed engines, the following 5-mode cycle 2 shall be followed in dynamometer operation on the test engine:
Mode Number Engine Speed Torque [per cent] Weighing Factor
1 Rated 100 0.05
2 Rated 75 0.25
3 Rated 50 0.30
4 Rated 25 0.30
5 Rated 10 0.10
The load figures are percentage values of the torque corresponding to the prime power 3 rating defined as the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals and under the stated ambient conditions, the maintenance being carried out as prescribed by the manufacturer.
Identical to C1 cycle as described in paragraph 8.3. of ISO 8178-4 : 2008. Identical to D2 cycle as described in paragraph 8.4. of ISO 8178-4 : 2008. For a better illustration of the prime power definition, see figure 2 of ISO 8528-1:1993(E).
Annex 5
Steady-state ramped-modal testing
(a) For variable-speed engines, the following 9-mode duty cycle applies in case of ramped-modal testing:
a,c b,c RMC mode Time in mode [s] Engine speed Torque (per cent)
1a Steady-state 126 Warm idle 0 (2) 1b Transition 20 Linear transition Linear transition 2a Steady-state 159 Intermediate 100 2b Transition 20 Intermediate Linear transition 3a Steady-state 160 Intermediate 50 3b Transition 20 Intermediate Linear transition 4a Steady-state 162 Intermediate 75 4b Transition 20 Linear transition Linear transition 5a Steady-state 246 Rated 100 5b Transition 20 Rated Linear transition 6a Steady-state 164 Rated 10 6b Transition 20 Rated Linear transition 7a Steady-state 248 Rated 75 7b Transition 20 Rated Linear transition 8a Steady-state 247 Rated 50 8b Transition 20 Linear transition Linear transition 9 Steady-state 128 Warm idle 0 a Speed terms as per footnote of the steady-state discrete mode test. b The percent torque is relative to the maximum torque at the commanded engine speed. c Advance from one mode to the next within a 20 s transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting
(b) For constant-speed engines, the following 5-mode duty cycle applies in case of ramped-modal testing:
a,b RMC mode Time in mode [s] Engine speed Torque (per cent)
1a Steady-state 53 Engine governed 100 1b Transition 20 Engine governed Linear transition 2a Steady-state 101 Engine governed 10 2b Transition 20 Engine governed Linear transition 3a Steady-state 277 Engine governed 75 3b Transition 20 Engine governed Linear transition 4a Steady-state 339 Engine governed 25 4b Transition 20 Engine governed Linear transition 5 Steady-state 350 Engine governed 50 a The percent torque is relative to maximum test torque. b Advance from one mode to the next within a 20 s transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode.
Annex 5
Transient cycle
(a) For variable-speed engines, the following full transient (variable speed and variable load) engine dynamometer schedule applies: Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 1 0 0 51 102 50 101 75 24 2 0 0 52 102 46 102 73 30 3 0 0 53 102 41 103 74 24 4 0 0 54 102 31 104 77 6 5 0 0 55 89 2 105 76 12 6 0 0 56 82 0 106 74 39 7 0 0 57 47 1 107 72 30 8 0 0 58 23 1 108 75 22 9 0 0 59 1 3 109 78 64 10 0 0 60 1 8 110 102 34 11 0 0 61 1 3 111 103 28 12 0 0 62 1 5 112 103 28 13 0 0 63 1 6 113 103 19 14 0 0 64 1 4 114 103 32 15 0 0 65 1 4 115 104 25 16 0 0 66 0 6 116 103 38 17 0 0 67 1 4 117 103 39 18 0 0 68 9 21 118 103 34 19 0 0 69 25 56 119 102 44 20 0 0 70 64 26 120 103 38 21 0 0 71 60 31 121 102 43 22 0 0 72 63 20 122 103 34 23 0 0 73 62 24 123 102 41 24 1 3 74 64 8 124 103 44 25 1 3 75 58 44 125 103 37 26 1 3 76 65 10 126 103 27 27 1 3 77 65 12 127 104 13 28 1 3 78 68 23 128 104 30 29 1 3 79 69 30 129 104 19 30 1 6 80 71 30 130 103 28 31 1 6 81 74 15 131 104 40 32 2 1 82 71 23 132 104 32 33 4 13 83 73 20 133 101 63 34 7 18 84 73 21 134 102 54 35 9 21 85 73 19 135 102 52 36 17 20 86 70 33 136 102 51 37 33 42 87 70 34 137 103 40 38 57 46 88 65 47 138 104 34 39 44 33 89 66 47 139 102 36 40 31 0 90 64 53 140 104 44 41 22 27 91 65 45 141 103 44 42 33 43 92 66 38 142 104 33 43 80 49 93 67 49 143 102 27 44 105 47 94 69 39 144 103 26 45 98 70 95 69 39 145 79 53 46 104 36 96 66 42 146 51 37 47 104 65 97 71 29 147 24 23 48 96 71 98 75 29 148 13 33 49 101 62 99 72 23 149 19 55 50 102 51 100 74 22 150 45 30
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 151 34 7 200 3 8 249 54 39 152 14 4 201 3 22 250 60 42 153 8 16 202 12 20 251 48 18 154 15 6 203 14 20 252 54 51 155 39 47 204 16 17 253 88 90 156 39 4 205 20 18 254 103 84 157 35 26 206 27 34 255 103 85 158 27 38 207 32 33 256 102 84 159 43 40 208 41 31 257 58 66 160 14 23 209 43 31 258 64 97 161 10 10 210 37 33 259 56 80 162 15 33 211 26 18 260 51 67 163 35 72 212 18 29 261 52 96 164 60 39 213 14 51 262 63 62 165 55 31 214 13 11 263 71 6 166 47 30 215 12 9 264 33 16 167 16 7 216 15 33 265 47 45 168 0 6 217 20 25 266 43 56 169 0 8 218 25 17 267 42 27 170 0 8 219 31 29 268 42 64 171 0 2 220 36 66 269 75 74 172 2 17 221 66 40 270 68 96 173 10 28 222 50 13 271 86 61 174 28 31 223 16 24 272 66 0 175 33 30 224 26 50 273 37 0 176 36 0 225 64 23 274 45 37 177 19 10 226 81 20 275 68 96 178 1 18 227 83 11 276 80 97 179 0 16 228 79 23 277 92 96 180 1 3 229 76 31 278 90 97 181 1 4 230 68 24 279 82 96 182 1 5 231 59 33 280 94 81 183 1 6 232 59 3 281 90 85 184 1 5 233 25 7 282 96 65 185 1 3 234 21 10 283 70 96 186 1 4 235 20 19 284 55 95 187 1 4 236 4 10 285 70 96 188 1 6 237 5 7 286 79 96 189 8 18 238 4 5 287 81 71 190 20 51 239 4 6 288 71 60 191 49 19 240 4 6 289 92 65 192 41 13 241 4 5 290 82 63 193 31 16 242 7 5 291 61 47 194 28 21 243 16 28 292 52 37 195 21 17 244 28 25 293 24 0 196 31 21 245 52 53 294 20 7 197 21 8 246 50 8 295 39 48 198 0 14 247 26 40 296 39 54 199 0 12 248 48 29 297 63 58
Annex 5
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 298 53 31 347 57 79 396 60 90 299 51 24 348 76 97 397 53 66 300 48 40 349 84 97 398 70 48 301 39 0 350 86 97 399 77 93 302 35 18 351 81 98 400 79 67 303 36 16 352 83 83 401 46 65 304 29 17 353 65 96 402 69 98 305 28 21 354 93 72 403 80 97 306 31 15 355 63 60 404 74 97 307 31 10 356 72 49 405 75 98 308 43 19 357 56 27 406 56 61 309 49 63 358 29 0 407 42 0 310 78 61 359 18 13 408 36 32 311 78 46 360 25 11 409 34 43 312 66 65 361 28 24 410 68 83 313 78 97 362 34 53 411 102 48 314 84 63 363 65 83 412 62 0 315 57 26 364 80 44 413 41 39 316 36 22 365 77 46 414 71 86 317 20 34 366 76 50 415 91 52 318 19 8 367 45 52 416 89 55 319 9 10 368 61 98 417 89 56 320 5 5 369 61 69 418 88 58 321 7 11 370 63 49 419 78 69 322 15 15 371 32 0 420 98 39 323 12 9 372 10 8 421 64 61 324 13 27 373 17 7 422 90 34 325 15 28 374 16 13 423 88 38 326 16 28 375 11 6 424 97 62 327 16 31 376 9 5 425 100 53 328 15 20 377 9 12 426 81 58 329 17 0 378 12 46 427 74 51 330 20 34 379 15 30 428 76 57 331 21 25 380 26 28 429 76 72 332 20 0 381 13 9 430 85 72 333 23 25 382 16 21 431 84 60 334 30 58 383 24 4 432 83 72 335 63 96 384 36 43 433 83 72 336 83 60 385 65 85 434 86 72 337 61 0 386 78 66 435 89 72 338 26 0 387 63 39 436 86 72 339 29 44 388 32 34 437 87 72 340 68 97 389 46 55 438 88 72 341 80 97 390 47 42 439 88 71 342 88 97 391 42 39 440 87 72 343 99 88 392 27 0 441 85 71 344 102 86 393 14 5 442 88 72 345 100 82 394 14 14 443 88 72 346 74 79 395 24 54 444 84 72
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 445 83 73 495 51 61 545 24 72 446 77 73 496 68 47 546 64 70 447 74 73 497 29 42 547 77 62 448 76 72 498 24 73 548 80 68 449 46 77 499 64 71 549 83 53 450 78 62 500 90 71 550 83 50 451 79 35 501 100 61 551 83 50 452 82 38 502 94 73 552 85 43 453 81 41 503 84 73 553 86 45 454 79 37 504 79 73 554 89 35 455 78 35 505 75 72 555 82 61 456 78 38 506 78 73 556 87 50 457 78 46 507 80 73 557 85 55 458 75 49 508 81 73 558 89 49 459 73 50 509 81 73 559 87 70 460 79 58 510 83 73 560 91 39 461 79 71 511 85 73 561 72 3 462 83 44 512 84 73 562 43 25 463 53 48 513 85 73 563 30 60 464 40 48 514 86 73 564 40 45 465 51 75 515 85 73 565 37 32 466 75 72 516 85 73 566 37 32 467 89 67 517 85 72 567 43 70 468 93 60 518 85 73 568 70 54 469 89 73 519 83 73 569 77 47 470 86 73 520 79 73 570 79 66 471 81 73 521 78 73 571 85 53 472 78 73 522 81 73 572 83 57 473 78 73 523 82 72 573 86 52 474 76 73 524 94 56 574 85 51 475 79 73 525 66 48 575 70 39 476 82 73 526 35 71 576 50 5 477 86 73 527 51 44 577 38 36 478 88 72 528 60 23 578 30 71 479 92 71 529 64 10 579 75 53 480 97 54 530 63 14 580 84 40 481 73 43 531 70 37 581 85 42 482 36 64 532 76 45 582 86 49 483 63 31 533 78 18 583 86 57 484 78 1 534 76 51 584 89 68 485 69 27 535 75 33 585 99 61 486 67 28 536 81 17 586 77 29 487 72 9 537 76 45 587 81 72 488 71 9 538 76 30 588 89 69 489 78 36 539 80 14 589 49 56 490 81 56 540 71 18 590 79 70 491 75 53 541 71 14 591 104 59 492 60 45 542 71 11 592 103 54 493 50 37 543 65 2 593 102 56 494 66 41 544 31 26 594 102 56
Annex 5
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 595 103 61 644 79 72 693 100 69 596 102 64 645 78 70 694 102 72 597 103 60 646 80 70 695 101 69 598 93 72 647 82 71 696 100 69 599 86 73 648 84 71 697 102 71 600 76 73 649 83 71 698 102 71 601 59 49 650 83 73 699 102 69 602 46 22 651 81 70 700 102 71 603 40 65 652 80 71 701 102 68 604 72 31 653 78 71 702 100 69 605 72 27 654 76 70 703 102 70 606 67 44 655 76 70 704 102 68 607 68 37 656 76 71 705 102 70 608 67 42 657 79 71 706 102 72 609 68 50 658 78 71 707 102 68 610 77 43 659 81 70 708 102 69 611 58 4 660 83 72 709 100 68 612 22 37 661 84 71 710 102 71 613 57 69 662 86 71 711 101 64 614 68 38 663 87 71 712 102 69 615 73 2 664 92 72 713 102 69 616 40 14 665 91 72 714 101 69 617 42 38 666 90 71 715 102 64 618 64 69 667 90 71 716 102 69 619 64 74 668 91 71 717 102 68 620 67 73 669 90 70 718 102 70 621 65 73 670 90 72 719 102 69 622 68 73 671 91 71 720 102 70 623 65 49 672 90 71 721 102 70 624 81 0 673 90 71 722 102 62 625 37 25 674 92 72 723 104 38 626 24 69 675 93 69 724 104 15 627 68 71 676 90 70 725 102 24 628 70 71 677 93 72 726 102 45 629 76 70 678 91 70 727 102 47 630 71 72 679 89 71 728 104 40 631 73 69 680 91 71 729 101 52 632 76 70 681 90 71 730 103 32 633 77 72 682 90 71 731 102 50 634 77 72 683 92 71 732 103 30 635 77 72 684 91 71 733 103 44 636 77 70 685 93 71 734 102 40 637 76 71 686 93 68 735 103 43 638 76 71 687 98 68 736 103 41 639 77 71 688 98 67 737 102 46 640 77 71 689 100 69 738 103 39 641 78 70 690 99 68 739 102 41 642 77 70 691 100 71 740 103 41 643 77 71 692 99 68 741 102 38
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 742 103 39 792 52 5 842 81 27 743 102 46 793 48 5 843 80 26 744 104 46 794 48 7 844 80 26 745 103 49 795 48 5 845 81 25 746 102 45 796 48 6 846 80 21 747 103 42 797 48 4 847 81 20 748 103 46 798 52 6 848 83 21 749 103 38 799 51 5 849 83 15 750 102 48 800 51 6 850 83 12 751 103 35 801 51 6 851 83 9 752 102 48 802 52 5 852 83 8 753 103 49 803 52 5 853 83 7 754 102 48 804 57 44 854 83 6 755 102 46 805 98 90 855 83 6 756 103 47 806 105 94 856 83 6 757 102 49 807 105 100 857 83 6 758 102 42 808 105 98 858 83 6 759 102 52 809 105 95 859 76 5 760 102 57 810 105 96 860 49 8 761 102 55 811 105 92 861 51 7 762 102 61 812 104 97 862 51 20 763 102 61 813 100 85 863 78 52 764 102 58 814 94 74 864 80 38 765 103 58 815 87 62 865 81 33 766 102 59 816 81 50 866 83 29 767 102 54 817 81 46 867 83 22 768 102 63 818 80 39 868 83 16 769 102 61 819 80 32 869 83 12 770 103 55 820 81 28 870 83 9 771 102 60 821 80 26 871 83 8 772 102 72 822 80 23 872 83 7 773 103 56 823 80 23 873 83 6 774 102 55 824 80 20 874 83 6 775 102 67 825 81 19 875 83 6 776 103 56 826 80 18 876 83 6 777 84 42 827 81 17 877 83 6 778 48 7 828 80 20 878 59 4 779 48 6 829 81 24 879 50 5 780 48 6 830 81 21 880 51 5 781 48 7 831 80 26 881 51 5 782 48 6 832 80 24 882 51 5 783 48 7 833 80 23 883 50 5 784 67 21 834 80 22 884 50 5 785 105 59 835 81 21 885 50 5 786 105 96 836 81 24 886 50 5 787 105 74 837 81 24 887 50 5 788 105 66 838 81 22 888 51 5 789 105 62 839 81 22 889 51 5 790 105 66 840 81 21 890 51 5 791 89 41 841 81 31 891 63 50
Annex 5
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 892 81 34 941 81 31 990 81 27 893 81 25 942 81 30 991 81 23 894 81 29 943 81 35 992 81 25 895 81 23 944 81 28 993 81 26 896 80 24 945 81 27 994 81 22 897 81 24 946 80 27 995 81 20 898 81 28 947 81 31 996 81 17 899 81 27 948 81 41 997 81 23 900 81 22 949 81 41 998 83 65 901 81 19 950 81 37 999 81 54 902 81 17 951 81 43 1000 81 50 903 81 17 952 81 34 1001 81 41 904 81 17 953 81 31 1002 81 35 905 81 15 954 81 26 1003 81 37 906 80 15 955 81 23 1004 81 29 907 80 28 956 81 27 1005 81 28 908 81 22 957 81 38 1006 81 24 909 81 24 958 81 40 1007 81 19 910 81 19 959 81 39 1008 81 16 911 81 21 960 81 27 1009 80 16 912 81 20 961 81 33 1010 83 23 913 83 26 962 80 28 1011 83 17 914 80 63 963 81 34 1012 83 13 915 80 59 964 83 72 1013 83 27 916 83 100 965 81 49 1014 81 58 917 81 73 966 81 51 1015 81 60 918 83 53 967 80 55 1016 81 46 919 80 76 968 81 48 1017 80 41 920 81 61 969 81 36 1018 80 36 921 80 50 970 81 39 1019 81 26 922 81 37 971 81 38 1020 86 18 923 82 49 972 80 41 1021 82 35 924 83 37 973 81 30 1022 79 53 925 83 25 974 81 23 1023 82 30 926 83 17 975 81 19 1024 83 29 927 83 13 976 81 25 1025 83 32 928 83 10 977 81 29 1026 83 28 929 83 8 978 83 47 1027 76 60 930 83 7 979 81 90 1028 79 51 931 83 7 980 81 75 1029 86 26 932 83 6 981 80 60 1030 82 34 933 83 6 982 81 48 1031 84 25 934 83 6 983 81 41 1032 86 23 935 71 5 984 81 30 1033 85 22 936 49 24 985 80 24 1034 83 26 937 69 64 986 81 20 1035 83 25 938 81 50 987 81 21 1036 83 37 939 81 43 988 81 29 1037 84 14 940 81 42 989 81 29 1038 83 39
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 1039 76 70 1088 100 31 1137 78 2 1040 78 81 1089 100 28 1138 76 34 1041 75 71 1090 98 3 1139 67 80 1042 86 47 1091 102 26 1140 70 67 1043 83 35 1092 95 64 1141 53 70 1044 81 43 1093 102 23 1142 72 65 1045 81 41 1094 102 25 1143 60 57 1046 79 46 1095 98 42 1144 74 29 1047 80 44 1096 93 68 1145 69 31 1048 84 20 1097 101 25 1146 76 1 1049 79 31 1098 95 64 1147 74 22 1050 87 29 1099 101 35 1148 72 52 1051 82 49 1100 94 59 1149 62 96 1052 84 21 1101 97 37 1150 54 72 1053 82 56 1102 97 60 1151 72 28 1054 81 30 1103 93 98 1152 72 35 1055 85 21 1104 98 53 1153 64 68 1056 86 16 1105 103 13 1154 74 27 1057 79 52 1106 103 11 1155 76 14 1058 78 60 1107 103 11 1156 69 38 1059 74 55 1108 103 13 1157 66 59 1060 78 84 1109 103 10 1158 64 99 1061 80 54 1110 103 10 1159 51 86 1062 80 35 1111 103 11 1160 70 53 1063 82 24 1112 103 10 1161 72 36 1064 83 43 1113 103 10 1162 71 47 1065 79 49 1114 102 18 1163 70 42 1066 83 50 1115 102 31 1164 67 34 1067 86 12 1116 101 24 1165 74 2 1068 64 14 1117 102 19 1166 75 21 1069 24 14 1118 103 10 1167 74 15 1070 49 21 1119 102 12 1168 75 13 1071 77 48 1120 99 56 1169 76 10 1072 103 11 1121 96 59 1170 75 13 1073 98 48 1122 74 28 1171 75 10 1074 101 34 1123 66 62 1172 75 7 1075 99 39 1124 74 29 1173 75 13 1076 103 11 1125 64 74 1174 76 8 1077 103 19 1126 69 40 1175 76 7 1078 103 7 1127 76 2 1176 67 45 1079 103 13 1128 72 29 1177 75 13 1080 103 10 1129 66 65 1178 75 12 1081 102 13 1130 54 69 1179 73 21 1082 101 29 1131 69 56 1180 68 46 1083 102 25 1132 69 40 1181 74 8 1084 102 20 1133 73 54 1182 76 11 1085 96 60 1134 63 92 1183 76 14 1086 99 38 1135 61 67 1184 74 11 1087 102 24 1136 72 42 1185 74 18
Annex 5
Time Norm. Norm. Time Norm. Norm. Time Norm. Norm. Speed Torque Speed Torque Speed Torque s % % s % % s % % 1186 73 22 1236 0 0 1187 74 20 1237 0 0 1188 74 19 1238 0 0 1189 70 22 1190 71 23 1191 73 19 1192 73 19 1193 72 20 1194 64 60 1195 70 39 1196 66 56 1197 68 64 1198 30 68 1199 70 38 1200 66 47 1201 76 14 1202 74 18 1203 69 46 1204 68 62 1205 68 62 1206 68 62 1207 68 62 1208 68 62 1209 68 62 1210 54 50 1211 41 37 1212 27 25 1213 14 12 1214 0 0 1215 0 0 1216 0 0 1217 0 0 1218 0 0 1219 0 0 1220 0 0 1221 0 0 1222 0 0 1223 0 0 1224 0 0 1225 0 0 1226 0 0 1227 0 0 1228 0 0 1229 0 0 1230 0 0 1231 0 0 1232 0 0 1233 0 0 1234 0 0 1235 0 0
A graphical display of the NRTC dynamometer schedule is shown below
Speed (%) NRTC dynamometer schedule
0 200 400 600 800 1000 1200
Torque (%)
0 200 400 600 800 1000 1200 time [ s ]
Annex 6
Annex 6
Technical characteristics of reference fuel prescribed for approval tests and to verify conformity of production
For power bands D to G
1,2
Limits and Units Test Method
Cetane Number min. 457 ISO 5165
max. 50
Density at 15 °C min. 835 kg/m3 ISO 3675, ASTM D4052
max. 845 kg/m3 10
Distillation3 95 % point Maximum 370 °C ISO 3405
Viscosity at 40 °C Minimum 2.5 mm2/s ISO 3104
Maximum 3.5 mm /s
Sulphur content Minimum 0.1 % mass9 ISO 8754, EN 24260
Maximum 0.2 % mass8
Flash Point Minimum 55 °C ISO 2719
CFPP Minimum - EN 116
Maximum +5 °C
Copper corrosion Maximum 1 ISO 2160
Conradson carbon residue (10 per Maximum 0.3 % mass ISO 10370
cent DR)
Ash content Maximum 0.01 % mass ASTM D482 11
Water content Maximum 0.05 % mass ASTM D95, D1744
Neutralization (strong acid) number Minimum 0.20 mg KOH/g
Oxidation stability5 Maximum 2.5 mg/100 ml ASTM D2274
Additives6
If it is required to calculate thermal efficiency of an engine or vehicle, the calorific value of the fuel can be calculated from:
Specific energy (calorific value) (net) MJ/kg = (46.423 - 8.792 d2 + 3.170 d) × (1 - (x + y + s)) + 9.420 s - 2.499 x
where:
d is the density at 15 °C
x is the proportion by mass of water (%/100)
y is the proportion by mass of ash (%/100)
s is the proportion by mass of sulphur (%/100)
The values quoted in the specification are "true values". In establishment of their limit values the terms of ASTM D3244 "Defining a
basis for petroleum produce quality disputes" have been applied and in fixing a minimum value, a minimum difference of 2R above zero
has been taken into account; in fixing a maximum and minimum value, the minimum difference
is 4R (R = reproducibility).
Notwithstanding this measure, which is necessary for statistical reasons, the manufacturer of fuel should nevertheless aim at a zero value
where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it
be necessary to clarify the question as to whether a fuel meets the requirements of the specifications, the terms of ASTM D3244 should
be applied.
The figures quoted show the evaporated quantities (percentage recovered + percentage loss).
The range of cetane is not in accordance with the requirement of a minimum range of 4R. However, in cases of dispute between fuel
supplier and fuel user, the terms in ASTM D3244 can be used to resolve such disputes provided replicate measurements, of sufficient
number to achieve the necessary precision, are made in preference to single determinations.
Even though oxidation stability is controlled, it is likely that shelf life will be limited. Advice should be sought from the supplier as
to storage conditions and life.
This fuel should be based straight run and cracked hydrocarbon distillate components only; desulphurization is allowed. It shall not
contain any metallic additives or cetane improver additives.
Lower values are permitted, in which case the cetane number of the reference fuel used is to be reported.
Higher values are permitted, in which case the sulphur content of the reference fuel used is to be reported.
To be kept under constant review in the light of trends in the markets. For the purpose of the initial approval of an engine on request
of the applicant, a 0.05 per cent mass nominal sulphur level (minimum 0.03 per cent mass) is permissible, in which case the measured
particulate level shall be corrected upward to the average value that is nominally specified for fuel sulphur content (0.15 per cent mass)
per the equation below:
PTadj = PT + [SFC x 0.0917 x (NSLF - FSF)]
where:
PTadj = adjusted PT value (g/kWh)
PT = measured weighted specific emissions value for particulate emission (g/kWh)
SFC = weighted specific fuel consumption (g/kWh) calculated according to the formula as below
NSLF = average of the nominal specification of sulphur content mass fraction (i.e. 0.15 %/100)
FSF = fuel sulphur content mass fraction (%/100)
Equation for the calculation of the weighted specific fuel consumption:
n
∑G
i=1
FUEL,i x WF i
SFC = n
where : P i = P m,i + P AE,i
∑ P i x WF i
i =1
For the purpose of conformity of production assessments in accordance with paragraph 7.4.2., the requirements shall be met using
reference fuel which complies with the minimum/maximum level of 0.1/0.2 per cent mass.
Higher values are permitted up to 855 kg/m3, in which case the density of the reference fuel used is to be reported. For the purpose
of conformity of production assessments in accordance with paragraph 7.4.2., the requirements shall be met using reference fuel which
complies with the minimum/maximum level of 835/845 kg/m3.
To be replaced by EN/ISO 6245 with effect of the date of implementation.
All fuel characteristics and limit values are to be kept under review in light of trends in the markets.
Annex 6For power bands H to K
Limits
Parameter Unit minimum maximum Test Method
Cetane number 52.0 54.0 EN-ISO 5165
Density at 15°C kg/m3 833 837 EN-ISO 3675
Distillation:
50 per cent point °C 245 - EN-ISO 3405
95 per cent point °C 345 350 EN-ISO 3405
- Final boiling point °C - 370 EN-ISO 3405
Flash point °C 55 - EN 22719
CFPP °C - –5 EN 116
Viscosity at 40°C mm2/s 2.5 3.5 EN-ISO 3104
Polycyclic aromatic hydrocarbons per cent m/m 3.0 6.0 IP 391
Sulphur content3 mg/kg - 300 ASTM D 5453
Copper corrosion - class 1 EN-ISO 2160
Conradson carbon residue per cent m/m - 0.2 EN-ISO 10370
(10 per cent DR)
Ash content per cent m/m - 0.01 EN-ISO 6245
Water content per cent m/m - 0.05 EN-ISO 12937
Neutralization (strong acid) number mg KOH/g - 0.02 ASTM D 974
Oxidation stability4 mg/ml - 0.025 EN-ISO 12205
The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 "Petroleum
products – Determination and application of precision data in relation to methods of test" have been applied and in fixing a minimum
value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum
difference is 4R (R = reproducibility).
Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels should nevertheless aim at a zero value
where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it
be necessary to clarify the questions as to whether a fuel meets the requirements of the specifications, the terms of ISO 4259 should be
applied.
The range for the cetane number is not in accordance with the requirements of a minimum range of 4R. However, in the case of a
dispute between fuel supplier and fuel user, the terms of ISO 4259 may be used to resolve such disputes provided replicate
measurements, of sufficient number to archive the necessary precision, are made in preference to single determinations.
The actual sulphur content of the fuel used for the test shall be reported.
Even though oxidation stability is controlled, it is likely that shelf life will be limited. Advice should be sought from the supplier as
to storage conditions and life.For power bands L to P and Q and R
Limits Parameter Unit minimum maximum Test Method Cetane number 54.0 EN-ISO 5165 Density at 15 °C kg/m3 833 865 EN-ISO 3675 Distillation: 50 per cent point °C 245 - EN-ISO 3405 95 per cent point °C 345 350 EN-ISO 3405 - Final boiling point °C - 370 EN-ISO 3405 Flash point °C 55 - EN 22719 CFPP °C - –5 EN 116 Viscosity at 40 °C mm2/s 2.3 3.3 EN-ISO 3104 Polycyclic aromatic hydrocarbons per cent m/m 3.0 6.0 IP 391 Sulphur content3 mg/kg - 10 ASTM D 5453 Copper corrosion - class 1 EN-ISO 2160 Conradson carbon residue per cent m/m - 0.2 EN-ISO 10370 (10 per cent DR) Ash content per cent m/m - 0.01 EN-ISO 6245 Water content per cent m/m - 0.02 EN-ISO 12937 Neutralization (strong acid) number mg KOH/g - 0.02 ASTM D 974 Oxidation stability4 mg/ml - 0.025 EN-ISO 12205 Lubricity (HFRR wear scar diameter at 60 °C) μm - 400 CEC F-06-A-96 FAME prohibited The values quoted in the specifications are "true values". In establishment of their limit values the terms of ISO 4259 "Petroleum products – Determination and application of precision data in relation to methods of test" have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account; in fixing a maximum and minimum value, the minimum difference is 4R (R = reproducibility). Notwithstanding this measure, which is necessary for technical reasons, the manufacturer of fuels should nevertheless aim at a zero value where the stipulated maximum value is 2R and at the mean value in the case of quotations of maximum and minimum limits. Should it be necessary to clarify the questions as to whether a fuel meets the requirements of the specifications, the terms of ISO 4259 should be applied. The range for the cetane number is not in accordance with the requirements of a minimum range of 4R. However, in the case of a dispute between fuel supplier and fuel user, the terms of ISO 4259 may be used to resolve such disputes provided replicate measurements, of sufficient number to archive the necessary precision, are made in preference to single determinations. The actual sulphur content of the fuel used for the Type I test shall be reported. Even though oxidation stability is controlled, it is likely that shelf life will be limited. Advice should be sought from the supplier as to storage conditions and life. Annex 7
Annex 7 — Installation requirements for equipment and auxiliaries
Number Equipment and auxiliaries Fitted for emission test
1 Inlet system Inlet manifold Yes Crankcase emission control system Yes Air flow-meter Yes Air filter Yesa Inlet silencer Yesa Induction-heating device of inlet manifold Yes, standard production equipment. If possible to be set in the most favourable condition
2 Exhaust system Exhaust aftertreatment Yes Exhaust manifold Yes Connecting pipes Yesb Silencer Yesb Tail pipe Yesb Exhaust brake Noc Pressure charging device Yes
3 Fuel supply pump Yesd
4 Fuel injection equipment Prefilter Yes Filter Yes Pump Yes High-pressure pipe Yes Injector Yes Electronic control unit, sensors, etc. Yes Governor/control system Yes
Number Equipment and auxiliaries Fitted for emission test
Automatic full-load stop for the control rack Yes depending on atmospheric conditions
5 Liquid-cooling equipment Radiator No Fan No Fan cowl No Water pump Yese Thermostat Yesf
6 Air cooling Cowl Nog Fan or Blower Nog Temperature-regulating device No
7 Electrical equipment Generator Yesh
8 Pressure charging equipment Compressor driven either directly by the Yes engine and/or by the exhaust gases Charge air cooler Yesg,i Coolant pump or fan (engine-driven) Nog Coolant flow control device Yes
9 Auxiliary test-bed fan Yes, if necessary
10 Anti-pollution device Yes
11 Starting equipment Yes or test bed equipmentj
12 Lubricating oil pump Yes
13 Certain auxiliaries whose definition is linked No with the operation of the machine and which may be mounted on the engine shall be removed for the test. The following non-exhaustive list is given as an example:
(i) air compressor for brakes
(ii) power steering compressor
(iii) suspension compressor
(iv) air-conditioning system.
Annex 7
a The complete inlet system shall be fitted as provided for the intended application:
(i) where there is a risk of an appreciable effect on the engine power;
(ii) when the manufacturer requests that this should be done. In other cases, an equivalent system may be used and a check should be made to ascertain that the intake pressure does not differ by more than 100 Pa from the upper limit specified by the manufacturer for a clean air filter. b The complete exhaust system shall be fitted as provided for the intended application:
(i) where there is a risk of an appreciable effect on the engine power;
(ii) when the manufacturer requests that this should be done. In other cases, an equivalent system may be installed provided the pressure measured does not differ by more than 1,000 Pa from the upper limit specified by the manufacturer. c If an exhaust brake is incorporated in the engine, the throttle valve shall be fixed in the fully open position. d The fuel feed pressure may be adjusted, if necessary, to reproduce the pressure existing in the particular engine application (particularly when a "fuel return" system is used). e The cooling-liquid circulation shall be operated by the engine water pump only. Cooling of the liquid may be produced by an external circuit, such that the pressure loss of this circuit and the pressure at the pump inlet remain substantially the same as those of the engine cooling system. f The thermostat may be fixed in the fully open position. g When the cooling fan or blower is fitted for the test, the power absorbed shall be added to the results, except for cooling fans of air cooled engines directly fitted on the crankshaft. The fan or blower power shall be determined at the speeds used for the test either by calculation from standard characteristics or by practical tests. h Minimum power of the generator: the electrical power of the generator shall be limited to that necessary for operation of accessories which are indispensable for engine operation. If the connection of a battery is necessary, a fully charged battery in good condition shall be used. i Charge air-cooled engines shall be tested with charge air cooling, whether liquid - or air-cooled, but if the manufacturer prefers, a test bench system may replace the air cooler. In either case, the measurement of power at each speed shall be made with the maximum pressure drop and the minimum temperature drop of the engine air across the charge air cooler on the test bench system as those specified by the manufacturer. j The power for electrical or other starting systems shall be provided from the test bed.
Annex 8 — Durability requirements
This Annex shall apply to CI engines from power bands H upwards only.
1.Verifying the durability of engines for power bands H to P
This section shall apply to CI engines for power bands H to P only.
Manufacturers shall determine a Deterioration Factor (DF) value for each regulated pollutant. Such DFs shall be used for type approval and production line testing, by either:
(a) Adding the DF to the emission test result, if paragraph 1.2.1. applies, or
(b) Multiplying the emission test result with the DF, if paragraph 1.2.2. applies.
Test to establish DFs shall be conducted as follows:
The manufacturer shall conduct durability tests to accumulate engine operating hours according to a test schedule that is selected on the basis of good engineering judgement to be representative of in-use engine operation in respect to characterising emission performance deterioration. The durability test period should typically represent the equivalent of at least one quarter of the emission durability period (EDP). Service accumulation operating hours may be acquired through running engines on a dynamometer test bed or from actual in-field machine operation. Accelerated durability tests can be applied whereby the service accumulation test schedule is performed at a higher load factor than typically experienced in the field. The acceleration factor relating the number of engine durability test hours to the equivalent number of EDP hours shall be determined by the engine manufacturer based on good engineering judgement. During the period of the durability test, no emission sensitive components can be serviced or replaced other than to the routine service schedule recommended by the manufacturer. The test engine, subsystems, or components to be used to determine exhaust emission DFs for an engine family, or for engine families of equivalent emission control system technology, shall be selected by the engine manufacturer on the basis of good engineering judgement. The criterion is that the test engine should represent the emission deterioration characteristic of the engine families that will apply the resulting DF values for certification approval. Engines of different bore and stroke, different configuration, different air management systems, different fuel systems can be considered as equivalent in respect to emissions deterioration characteristics if there is a reasonable technical basis for such determination.
Annex 8
DF values from another manufacturer can be applied if there is a reasonable basis for considering technology equivalence with respect to emissions deterioration, and evidence that the tests have been carried according to the specified requirements. Emissions testing will be performed according to the procedures defined in this Regulation for the test engine after initial run-in but before any service accumulation, and at the completion of the durability. Emission tests can also be performed at intervals during the service accumulation test period, and applied in determining the deterioration trend.
The service accumulation tests or the emissions tests performed to determine deterioration shall not be witnessed by the approval authority.
Determination of DF values from durability tests
An additive DF is defined as the value obtained by subtraction of the emission value determine at the beginning of the EDP, from the emissions value determined to represent the emission performance at the end of the EDP. A multiplicative DF is defined as the emission level determined for the end of the EDP divided by the emission value recorded at the beginning of the EDP. Separate DF values shall be established for each of the pollutants covered by the legislation. In the case of establishing a DF value relative to the NOx + HC standard, for an additive DF, this is determined based on the sum of the pollutants notwithstanding that a negative deterioration for one pollutant may not offset deterioration for the other. For a multiplicative NOx + HC DF, separate HC and NOx DFs shall be determined and applied separately when calculating the deteriorated emission levels from an emissions test result before combining the resultant deteriorated NOx and HC values to establish compliance with the standard. In cases where the testing is not conducted for the full EDP, the emission values at the end of the EDP is determined by extrapolation of the emission deterioration trend established for the test period, to the full EDP. When emissions test results have been recorded periodically during the service accumulation durability testing, standard statistical processing techniques based on good practice shall be applied to determine the emission levels at the end of the EDP; statistical significance testing can be applied in the determination of the final emissions values. If the calculation results in a value of less than 1.00 for a multiplicative DF, or less than 0.00 for an additive DF, then the DF shall be 1.0 or 0.00, respectively.
A manufacturer may, with the approval of the Type Approval Authority, use
DF values established from results of durability tests conducted to obtain DF values for certification of on-road HD CI engines. This will be allowed if there is technological equivalency between the test on-road engine and the non-road engine families applying the DF values for certification. The DF values derived from on-road engine emission durability test results shall be calculated on the basis of EDP values defined in paragraph 2.
In the case where an engine family uses established technology, an analysis based on good engineering practices may be used in lieu of testing to determine a deterioration factor for that engine family subject to approval of the Type Approval Authority.
DF information in approval applications
Additive DFs shall be specified for each pollutant in an engine family certification application for CI engines not using any after-treatment device.
Multiplicative DFs shall be specified for each pollutant in an engine family certification application for CI engines using an after-treatment device.
The manufacturer shall furnish to the Type Approval Authority on request with information to support the DF values. This would typically include emission test results, service accumulation test schedule, maintenance procedures together with information to support engineering judgements of technological equivalency, if applicable.
Verifying the durability of engines for power bands Q and R (Reserved) Until such time as a separate method for verifying the durability of engines for power bands Q and R is introduced into this Regulation, section 1 of this annex shall apply to power bands Q and R.
3.Emission durability periods
Manufacturers shall use the EDP in Table 1 of this paragraph.
EDP categories for CI engines from power bands from H upwards (hours)
Useful life (hours) Category (power band) (PDE) ≤ 37 kW (constant speed engines) 3,000 ≤ 37 kW (variable speed engines) 5,000 > 37 kW 8,000