CHAPTER 1GENERAL PROVISIONS
Article 1Subject matter
This Regulation complements the legal framework for the type-approval of motor vehicles and engines with regard to emissions established by Regulation (EU) No 582/2011 by laying down the rules for issuing licences to operate a simulation tool with a view to determining CO2 emissions and fuel consumption of new vehicles to be sold, registered or put into service in the Union and for operating that simulation tool and declaring the CO2 emissions and fuel consumption values thus determined.
Article 2Scope
Subject to Article 4, second paragraph, this Regulation shall apply to medium lorries, heavy lorries and heavy buses.
Changed in this versionIn the case of multi-stage type-approvals or individual approvals of medium and heavy lorries, this Regulation shall apply to base lorries. In the case of heavy buses, this Regulation shall apply to primary vehicles, interim vehicles and to complete vehicles or completed vehicles.
Changed in this versionThis Regulation shall not apply to off-road vehicles, special purpose vehicles and off-road special purpose vehicles as defined, respectively, in Part A, points 2.1., 2.2. and 2.3., of Annex I to Regulation (EU) 2018/858 of the European Parliament and of the Council ( 1 ).
Changed in this versionArticle 3DefinitionsChanged
For the purposes of this Regulation, the following definitions shall apply:
‘CO2 emissions and fuel consumption related properties’ means specific properties derived for a component, separate technical unit and system which determine the impact of the part on the CO2 emissions and fuel consumption of a vehicle;
Changed in this version‘input data’ means information on the CO2 emissions and fuel consumption related properties of a component, separate technical unit or system which is used by the simulation tool for the purpose of determining CO2 emissions and fuel consumption of a vehicle;
Changed in this version‘input information’ means information relating to the characteristics of a vehicle which is used by the simulation tool for the purposes of determining their CO2 emissions and fuel consumption of the vehicle and which is not part of an input data;
Changed in this version‘manufacturer’ means the person or body who is responsible to the approval authority for all aspects of the certification process and for ensuring conformity of CO2 emissions and fuel consumption related properties of components, separate technical units and systems. It is not essential that the person or body be directly involved in all stages of the construction of the component, separate technical unit or system which is the subject of the certification. ‘vehicle manufacturer’ means a body or person responsible for issuing the manufacturer's records file and the customer information file pursuant to Article 9;
Changed in this version‘authorised entity’ means a national authority authorised by a Member State to request relevant information from the manufacturers and vehicle manufacturers on the CO2 emissions and fuel consumption related properties of a specific component, specific separate technical unit or specific system and CO2 emissions and fuel consumption of new vehicles respectively.
Changed in this version‘transmission’ means a device consisting of at least of two shiftable gears, changing torque and speed with defined ratios;
Changed in this version‘torque converter’ means a hydrodynamic start-up component either as a separate component of the driveline or transmission with serial or parallel power flow that adapts speed between engine and wheel and provides torque multiplication;
Changed in this version‘other torque transferring component’ or ‘OTTC’ means a rotating component attached to the driveline which produces torque losses dependent on its own rotational speed;
Changed in this version‘additional driveline component’ or ‘ADC’ means a rotating component of the driveline which transfers or distributes power to other driveline components and produces torque losses dependant on its own rotational speed;
Changed in this version‘axle’ means a component comprising all rotating parts of the driveline which transfer the driving torque coming from the prop shaft to the wheels and changes the torque and speed with a fixed ratio and including the functions of a differential gear;
Changed in this version‘air drag’ means characteristic of a vehicle configuration regarding aerodynamic force acting on the vehicle in the direction of air flow and determined as a product of the drag coefficient and the cross sectional area for zero crosswind conditions;
Changed in this version‘auxiliaries’ means vehicle components including an engine fan, steering system, electric system, pneumatic system and Heating, Ventilation and Air Conditioning (HVAC) system whose CO2 emissions and fuel consumption properties have been defined in Annex IX;
Changed in this version‘component family’, ‘separate technical unit family’ or ‘system family’ means a manufacturer's grouping of components, separate technical units or systems, respectively, which through their design have similar CO2 emissions and fuel consumption related properties;
Changed in this version‘parent component’, ‘parent separate technical unit’ or ‘parent system’ means a component, separate technical unit or system, respectively, selected from a component, separate technical unit or system family, respectively, in such a way that its CO2 emissions and fuel consumption related properties will be the worst case for that component family, separate technical unit family or system family;
Changed in this version‘zero emission heavy-duty vehicle’ (Ze-HDV) means ‘zero emission heavy-duty vehicle’ as defined in Article 3, point (11), of Regulation (EU) 2019/1242 of the European Parliament and of the Council;
Changed in this version‘vocational vehicle’ means a heavy-duty vehicle not intended for the delivery of goods and for which one of the following digits is used to supplement the bodywork codes, as listed in Appendix 2 to Annex I to Regulation (EU) 2018/858: 09, 10, 15, 16, 18, 19, 20, 23, 24, 25, 26, 27, 28, 31; or a tractor with a maximum speed not exceeding 79 km/h;
Changed in this version‘rigid lorry’ means a ‘lorry’ as defined in Part C, point 4.1, of Annex I to Regulation (EU) 2018/858, except for the lorries designed or constructed for the towing of a semi-trailer;
Changed in this version‘tractor’ means a ‘tractor unit for semi-trailer’ as defined in Part C, point 4.3, of Annex I to Regulation (EU) 2018/858
Changed in this version‘sleeper cab’ means a type of cabin that has a compartment behind the driver's seat intended to be used for sleeping;
Changed in this version‘hybrid electric heavy-duty vehicle’ (He-HDV) means a hybrid heavy duty vehicle that, for the purpose of mechanical propulsion, draws energy from both of the following on-vehicle sources of stored energy or power: (i) a consumable fuel, and (ii) an electrical energy or power storage device;
Changed in this version‘dual-fuel vehicle’ is as defined in Article 2(48) of Regulation (EU) No 582/2011;
Changed in this version‘primary vehicle’ means a heavy bus in a virtual assembly condition determined for simulation purposes, for which the input data and input information as set out in Annex III is used;
Changed in this version‘manufacturer’s records file’ means a file produced by the simulation tool which contains manufacturer related information, a documentation of the input data and input information to the simulation tool and the results for CO2 emissions and fuel consumption;
Changed in this version‘customer information file’ means a file produced by the simulation tool which contains a defined set of vehicle related information and the results for CO2 emissions and fuel consumption as defined in Part II of Annex IV;
Changed in this version‘vehicle information file’ (VIF) means a file produced by the simulation tool for heavy buses to transfer the relevant input data, input information and simulation results to subsequent manufacturing stages following the method as described in point (2) of Annex I;
Changed in this version‘medium lorry’ means a vehicle of category N2, as defined in Article 4(1), point (b)(ii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass exceeding 5 000 kg and not exceeding 7 400 kg;
Changed in this version‘heavy lorry’ means a vehicle of category N2, as defined in Article 4(1), point (b)(ii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass exceeding 7 400 kg and a vehicle of category N3, as defined in Article 4(1), point (b)(iii), of that Regulation;
Changed in this version‘heavy bus’ means a vehicle of category M3, as defined in Article 4(1), point (a)(iii), of Regulation (EU) 2018/858, with a technically permissible maximum laden mass of more than 7 500 kg;
Changed in this version‘primary vehicle manufacturer’ means a manufacturer responsible for the primary vehicle;
Changed in this version‘interim vehicle’ means any further completion of a primary vehicle where a sub-set of input data and input information as defined for the complete or completed vehicle in accordance with Table 1 and Table 3a of Annex III is added and/or modified;
Changed in this version‘interim manufacturer’ means a manufacturer responsible for an interim vehicle;
Changed in this version‘incomplete vehicle’ means ‘incomplete vehicle’ as defined in Article 3, point (25), of Regulation (EU) 2018/858;
Changed in this version‘completed vehicle’ means ‘completed vehicle’ as defined in Article 3, point (26), of Regulation (EU) 2018/858;
Changed in this version‘complete vehicle’ means ‘complete vehicle’ as defined in Article 3, point (27), of Regulation (EU) 2018/858;
Changed in this version‘standard value’ is input data for the simulation tool for a component where certification of input data is applicable, but the component has not been tested to determine a specific value and which reflects the worst-case performance of a component;
Changed in this version‘generic value’ is data used in the simulation tool for components or vehicle parameters where no component testing or declaration of specific values is foreseen and which reflects performance of average component technology or typical vehicle specifications;
Changed in this version‘van’ means a ‘van’ as defined in Part C, point 4.2, of Annex I to Regulation (EU) 2018/858;
Changed in this version‘application case’ means the different scenarios to be followed in the case of a medium lorry, heavy lorry, heavy bus that is a primary vehicle, heavy bus that is an interim vehicle, heavy bus that is a complete vehicle or completed vehicle for which different manufacturer provisions and functions are applicable in the simulation tool;
Changed in this version‘base lorry’ means a medium lorry or heavy lorry equipped at least with:
Changed in this versionArticle 4Vehicle groups
For the purpose of this Regulation, motor vehicles shall be classified in vehicle groups in accordance with Annex I, Tables 1 to 6. Articles 5 to 23 do not apply to heavy lorries of vehicle groups 6, 7, 8, 13, 14, 15, 17, 18 and 19 as set out in Table 1 of Annex I, and to medium lorries of vehicle groups 51, 52, 55 and 56, as set out in Table 2 of Annex I and to any vehicle with a driven front axle in the vehicle groups 11, 12 and 16 as set out in Table 1 of Annex I.
Article 5Electronic tools
The Commission shall provide free of charge the following electronic tools in the form of downloadable and executable software:
(a)
a simulation tool;
(b)
pre-processing tools;
(c)
a hashing tool. The Commission shall maintain the electronic tools and provide modifications and updates to those tools.
Changed in this versionThe Commission shall make the electronic tools referred to in paragraph 1 available through a publicly available dedicated electronic distribution platform.
Changed in this version►M3
The simulation tool shall be used for the purposes of determining CO2 emissions and fuel consumption of new vehicles. ◄ The simulation tool shall be designed to operate on the basis of input information as specified in Annex III, as well as input data referred to in Article 12(1).
Changed in this versionThe pre-processing tools shall be used for the purpose of verification and compilation of the testing results and performing additional calculations relating to CO2 emission and fuel consumption related properties of certain components, separate technical units or systems and converting them in a format used by the simulation tool. The pre-processing tools shall be used by the manufacturer after performing the tests referred to in point 4 of Annex V for engines and in point 3 of Annex VIII for air-drag.
Changed in this versionThe hashing tools shall be used for establishing an unequivocal association between the certified CO2 emission and fuel consumption related properties of a component, separate technical unit or system and its certification document, as well as for establishing an unequivocal association between a vehicle and its manufacturer’s records file, vehicle information file and customer information file as referred to in Annex IV.
Changed in this versionCHAPTER 2LICENCE TO OPERATE THE SIMULATION TOOL FOR THE PURPOSES OF TYPE-APPROVAL WITH REGARD TO EMISSIONS
Article 6Application for a licence to operate the simulation tool with a view to determining CO2 emissions and fuel consumption of new vehicles
The vehicle manufacturer shall submit to the approval authority an application for a licence to operate the simulation tool for an application case with a view to determining CO2 emissions and fuel consumption of new vehicles belonging to one or more vehicle groups (‘licence’). An individual licence shall apply to only a single such application case. The application for a licence shall be accompanied by an adequate description of the processes set up by the vehicle manufacturer with a view to the operation of the simulation tool with respect to the application case concerned, as set out in point (1) of Annex II.
Changed in this versionThe application for a licence shall take the form of an information document drawn up in accordance with the model set out in Appendix 1 to Annex II.
Changed in this versionThe application for a licence shall be accompanied by an adequate description of the processes set up by the manufacturer for the purposes of determining CO2 emissions and fuel consumption with respect to all the vehicle groups concerned, as set out in point 1 of Annex II. It shall also be accompanied by the assessment report drafted by the approval authority after performing an assessment in accordance with point 2 of Annex II.
Changed in this versionThe vehicle manufacturer shall submit the application for a licence to the approval authority at the latest together with the application for an EC type-approval of a vehicle with an approved engine system with regard to emissions pursuant to Article 7 of Regulation (EU) No 582/2011, with the application for an EC type-approval of a vehicle with regard to emissions pursuant to Article 9 of that Regulation, with an application for a whole-vehicle type-approval pursuant to Regulation (EU) 2018/858 or the application for a national individual vehicle approval. The approval of a pure electric engine system and the EC type-approval of a pure electric vehicle with regard to emissions referred to in the previous sentence is limited to the measurement of net engine power in accordance with Annex XIV to Regulation (EU) No 582/2011. The application for a licence must concern the application case which includes the type of vehicle concerned by the application for EU type-approval.
Changed in this versionArticle 7Administrative provisions for the granting of the licence
The approval authority shall grant the licence if the vehicle manufacturer submits an application in accordance with Article 6 and proves that the requirements laid down in Annex II are met with respect to the application case concerned.
Changed in this versionThe licence shall be issued in accordance with the model set out in Appendix 2 to Annex II.
Changed in this versionArticle 8Subsequent changes to the processes set up for the purposes of determining CO2 emissions and fuel consumption of vehicles
The vehicle manufacturer shall apply for an extension of the licence in accordance with Article 6 (1), (2) and (3).
Changed in this versionAfter obtaining the licence, the vehicle manufacturer shall notify the approval authority without delay of any changes to the processes set up by it for the purposes of the licence for the application case covered by the licence that may affect the accuracy, reliability and stability of those processes.
Changed in this versionUpon receipt of the notification referred to in paragraph 3, the approval authority shall inform the vehicle manufacturer whether processes affected by the changes continue to be covered by the licence granted, whether the licence must be extended in accordance with paragraphs 1 and 2 or whether a new licence should be applied for in accordance with Article 6.
Changed in this versionWhere the changes are not covered by the licence, the manufacturer shall, within one month of receipt of the information referred to in paragraph 4, apply for an extension of the licence or for a new licence. If the manufacturer does not apply for an extension of the licence or a new licence within that deadline, or if the application is rejected, the licence shall be withdrawn.
Changed in this versionCHAPTER 3OPERATION OF THE SIMULATION TOOL WITH A VIEW TO DETERMINING THE CO2 EMISSIONS AND FUEL CONSUMPTION FOR THE PURPOSES OF REGISTRATION, SALE AND ENTRY INTO SERVICE OF NEW VEHICLES
Article 9Obligation to determine and declare CO2 emissions and fuel consumption of new vehicles
A vehicle manufacturer shall determine the CO2 emissions and fuel consumption of each new vehicle, with the exception of new vehicles using vehicle technologies listed in Appendix 1 to Annex III, to be sold, registered or put into service in the Union using the latest available version of the simulation tool referred to in Article 5(3). With regard to heavy buses the vehicle manufacturer or interim manufacturer shall use the method set out in Annex I, point (2). For vehicle technologies listed in Appendix 1 to Annex III to be sold, registered or put into service in the Union, the vehicle manufacturer or interim manufacturer shall determine only the input parameters specified for those vehicles in the models set out in Table 5 of Annex III, using the latest available version of the simulation tool referred to in Article 5(3). A vehicle manufacturer may operate the simulation tool for the purposes of this Article only if in possession of a licence granted for the application case concerned in accordance with Article 7. An interim manufacturer operates the simulation tool under the licence of a vehicle manufacturer.
Changed in this versionThe vehicle manufacturer shall record the results of the simulation performed in accordance with the first subparagraph of paragraph 1 in the manufacturer's records file drawn up in accordance with the model set out in Part I of Annex IV. With the exception of the cases referred to in the second subparagraph of Article 21(3), and in Article 23(6), any subsequent changes to the manufacturer's records file shall be prohibited. Vehicle manufacturers of heavy buses additionally shall record the results of the simulation in the vehicle information file. Interim manufacturers of heavy buses shall record the vehicle information file.
Changed in this versionThe vehicle manufacturer of medium lorries and heavy lorries shall create cryptographic hashes of the manufacturer’s records file and of the customer information file. The primary vehicle manufacturer shall create cryptographic hashes of the manufacturer’s records file and of the vehicle information file. The interim manufacturer shall create the cryptographic hash of the vehicle information file. The vehicle manufacturer of complete vehicles or completed vehicles that are heavy buses, shall create cryptographic hashes of the manufacturer’s records file, of the customer information file and of the vehicle information file.
Changed in this version►M3
Lorries and complete vehicles or completed vehicles that are heavy buses to be registered, sold or to enter into service shall be accompanied by the customer information file drawn up by the manufacturer in accordance with the model set out in Part II of Annex IV. ◄ Each customer information file shall include an imprint of the cryptographic hash of the manufacturer's records file referred to in paragraph 3. Vehicle manufacturers of heavy buses shall make the vehicle information file available to the manufacturer of a subsequent step in the chain.
Changed in this versionFor each vehicle accompanied by a certificate of conformity or, in the case of vehicles approved in accordance with Article 45 of Regulation (EU) 2018/858, an individual vehicle approval certificate, the certificate shall include an imprint of the cryptographic hashes referred to in paragraph 3 of this Article.
Changed in this versionIn accordance with point 11 of Annex III, a manufacturer may transfer results of the simulation tool to other vehicles.
Changed in this versionArticle 10Modifications, updates and malfunction of the electronic tools
In the case of modifications or updates to the simulation tool, the vehicle manufacturer shall start using the modified or updated simulation tool no later than 3 months after the modifications and updates were made available on the dedicated electronic distribution platform.
Changed in this versionIf the CO2 emissions and fuel consumption of new vehicles cannot be determined in accordance with Article 9(1) due to a malfunction of the simulation tool, the vehicle manufacturer shall notify the Commission thereof without delay by means of the dedicated electronic distribution platform.
Changed in this versionIf the CO2 emissions and fuel consumption of new vehicles cannot be determined in accordance with Article 9(1) due to a malfunction of the simulation tool, the vehicle manufacturer shall perform the simulation of those vehicles not later than 7 calendar days after the date referred to in point 1. Until then, the obligations resulting from Article 9 for the vehicles for which the determination of fuel consumption and CO2 emissions remains impossible shall be suspended. Where a malfunction of the simulation tool occurs at a step in the manufacturing chain of heavy buses prior to the complete or completed manufacturing steps, the obligation under Article 9(1) to operate the simulation tool at the subsequent manufacturing steps shall be postponed for a maximum of 14 calendar days after the date on which the manufacturer at the previous step made the vehicle information file available to the manufacturer of the complete or completed step.
Changed in this versionArticle 11Accessibility of the simulation tool inputs and output information
The manufacturer’s records file, the vehicle information file and the certificates on CO2 emissions and fuel consumption related properties of the components, systems and separate technical units shall be stored by the vehicle manufacturer for at least 20 years after the production of the vehicle and shall be available, upon request, to the approval authority and to the Commission.
Changed in this versionUpon request by an authorised entity of a Member State or by the Commission, the vehicle manufacturer shall provide, within 15 working days, the manufacturer’s records file or the vehicle information file.
Changed in this versionUpon request by an authorised entity of a Member State or by the Commission, the approval authority which granted the licence in accordance with Article 7 or certified the CO2 emissions and fuel consumption related properties of a component, separate technical unit or system in accordance with Article 17 shall provide, within 15 working days, the information document referred to in Article 6(2) or in Article 16(2), respectively.
Changed in this versionCHAPTER 4CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF COMPONENTS, SEPARATE TECHNICAL UNITS AND SYSTEMS
Article 12Components, separate technical units and systems relevant for the purposes of determining CO2 emissions and fuel consumption
The simulation tool input data referred to in Article 5(3) shall include information relating to the CO2 emissions and fuel consumption related properties of the following components, separate technical units and systems:
(a)
engines;
(b)
transmissions;
(c)
torque converters;
(d)
other torque transferring components;
(e)
additional driveline components;
(f)
axles;
▼M3
(g)
air drag;
▼B
(h)
auxiliaries;
(i)
tyres;
▼M3
(j)
electric powertrain components.
Changed in this versionThe CO2 emissions and fuel consumption related properties of the components, separate technical units and systems referred to in points (b) to (g), (i) and (j) of paragraph 1 of this Article shall be based either on the values determined, for each component, separate technical unit, system or if applicable their respective family, in accordance with Article 14 and certified in accordance with Article 17 (‘certified values’) or, in the absence of the certified values, on the standard values determined in accordance with Article 13.
Changed in this versionThe CO2 emissions and fuel consumption related properties of engines shall be based on the values determined for each engine family in accordance with Article 14 and certified in accordance with Article 17.
Changed in this versionThe CO2 emissions and fuel consumption related properties of auxiliaries shall be based on the generic values as implemented in the simulation tool and as allocated to a vehicle based on the input information to be determined in accordance with Annex IX.
Changed in this versionIn the case of a base lorry, the CO2 emissions and fuel consumption related properties of components, separate technical units and systems referred to in paragraph 1, point (g), of this Article, which cannot be determined for the base lorries shall be based on the standard values. For components, separate technical units and systems referred to in paragraph 1, point (h), the technology with highest power losses shall be selected by the vehicle manufacturer.
Changed in this versionIn the case of vehicles exempted from the obligation to determine the CO2 emissions and fuel consumption under Article 9(1), the simulation tool input data shall include the information set out in Table 5 of Annex III.
Changed in this versionWhere the vehicle is to be registered, sold or put into service with a complete set of snow tyres and a complete set of standard tyres, the vehicle manufacturer may choose which of the tyres to use for determining the CO2 emissions. In the case of heavy buses, as long as the tyres used in the primary vehicle simulation are with the vehicle when it is registered, sold or put into service, addition of tyre sets to the vehicle shall not result in the obligation to conduct a new primary vehicle simulation in accordance with point 2 of Annex I.
Changed in this versionArticle 13Standard values and generic values
The standard values for transmissions shall be determined in accordance with Appendix 8 of Annex VI.
Changed in this versionThe standard values for torque converters shall be determined in accordance with Appendix 9 of Annex VI.
Changed in this versionThe standard values for other torque-transferring components shall be determined in accordance with Appendix 10 of Annex VI.
Changed in this versionThe standard values for additional driveline components shall be determined in accordance with Appendix 11 of Annex VI.
Changed in this versionThe standard values for axles shall be determined in accordance with Appendix 3 of Annex VII.
Changed in this versionThe standard values for a body or trailer air drag shall be determined in accordance with Appendix 7 of Annex VIII.
Changed in this versionFor auxiliaries generic values are allocated by the simulation tool in accordance with the technologies selected in accordance with Annex IX.
Changed in this versionThe standard value for tyres shall be determined in accordance with Annex X, point 3.2.
Changed in this versionThe standard values for electric powertrain components shall be determined in accordance with Appendices 8, 9 and 10 to Annex Xb.
Changed in this versionArticle 14Certified values
The values determined in accordance with paragraphs 2 to 10 of this Article may be used by the vehicle manufacturer as the simulation tool input data if they are certified in accordance with Article 17.
Changed in this versionThe certified values for engines shall be determined in accordance with points 4, 5 and 6 of Annex V.
Changed in this versionThe certified values for transmissions shall be determined in accordance with point 3 of Annex VI.
Changed in this versionThe certified values for torque converters shall be determined in accordance with point 4 of Annex VI.
Changed in this versionThe certified values for other torque-transferring component shall be determined in accordance with point 5 of Annex VI.
Changed in this versionThe certified values for additional driveline components shall be determined in accordance with point 6 of Annex VI.
Changed in this versionThe certified values for axles shall be determined in accordance with point 4 of Annex VII.
Changed in this versionThe certified values for a body or trailer air drag shall be determined in accordance with point 3 of Annex VIII.
Changed in this versionThe certified values for tyres shall be determined in accordance with Annex X.
Changed in this versionThe certified values for electric powertrain components shall be determined in accordance with points 4, 5 and 6 of Annex Xb.
Changed in this versionArticle 15Family concept regarding components, separate technical units and systems using certified values
Subject to paragraphs 3 to 6, the certified values determined for a parent component, parent separate technical unit or parent system shall be valid, without further testing, for all family members in accordance with the family definition as set out in:
—
Appendix 6 to Annex VI as regards the family concept of transmissions, torque converters, other torque transferring component and additional driveline components;
—
Appendix 4 to Annex VII as regards the family concept of axles;
—
Appendix 5 to Annex VIII as regards the family concept for the purposes of determining air drag;
▼M3
—
Appendix 3 to Annex V as regards engines, the certified values for the members of an engine family created in accordance with the family definition shall be derived in accordance with points 4, 5 and 6 of Annex V;
—
Appendix 13 to Annex Xb as regards the family concept of electric machine systems or integrated electric powertrain components, the certified values for the members of a family created in accordance with the family definition of electric machine systems, shall be derived in accordance with point 4 of Annex Xb.
Changed in this versionFor engines, the certified values for the members of an engine family shall be derived in accordance with points 4, 5 and 6 of Annex V. For tyres, a family shall consist of one tyre type only. For electric machine systems or integrated electric powertrain components, the certified values for the members of a family of electric machine systems shall be derived in accordance with point 4 of Annex Xb.
Changed in this versionThe CO2 emissions and fuel consumption related properties of the parent component, parent separate technical unit or parent system shall not be better than the properties of any member of the same family.
Changed in this versionThe manufacturer shall provide the approval authority with evidence that the parent component, separate technical units or system fully represents the component family, separate technical unit family or system family. If, in the framework of testing for the purposes of the second subparagraph of Article 16(3), the approval authority determines that the selected parent component, parent separate technical unit or parent system does not fully represent the component family, separate technical unit family or system family, an alternative reference component, separate technical units or system may be selected by the approval authority, tested and shall become a parent component, parent separate technical unit or parent system.
Changed in this versionUpon request of the manufacturer, and subject to the agreement by the approval authority, the CO2 emissions and fuel consumption related properties of a specific component, specific separate technical unit or specific system other than a parent component, parent separate technical unit or parent system, respectively, may be indicated in the certificate on CO2 emissions and fuel consumption related properties of the component family, separate technical unit family or system family. The CO2 emissions and fuel consumption related properties of that specific component, separate technical unit or system shall be determined in accordance with Article 14.
Changed in this versionWhere the characteristics of the specific component, specific separate technical unit or specific system, in terms of CO2 emissions and fuel consumption related properties as determined in accordance with paragraph 5, lead to higher CO2 emissions and fuel consumption values than those of the parent component, parent separate technical unit or parent system, respectively, the manufacturer shall exclude it from the existing family, assign it to a new family and define it as the new parent component, parent separate technical unit or parent system for that family or apply for an extension of the certification pursuant to Article 18.
Changed in this versionArticle 16Application for a certification of the CO2 emissions and fuel consumption related properties of components, separate technical units or systems
The application for certification of the CO2 emissions and fuel consumption related properties of the component, separate technical unit and systems, or if applicable their respective families, shall be submitted to the approval authority.
Changed in this versionThe application for certification shall take the form of an information document drawn up in accordance with the model set out in:
—
Appendix 2 to Annex V as regards engines;
—
Appendix 2 to Annex VI as regards transmissions;
—
Appendix 3 to Annex VI as regards torque converters;
—
Appendix 4 to Annex VI as regards other torque transferring component;
—
Appendix 5 to Annex VI as regards additional driveline components;
—
Appendix 2 to Annex VII as regards axles;
—
Appendix 2 to Annex VIII as regards air drag;
—
Appendix 2 to Annex X as regards tyres;
▼M3
—
Appendixes 2 to 6 to Annex Xb as regards electric powertrain components.
Changed in this versionThe application for certification shall be accompanied by an explanation of the elements of design of the component, separate technical unit and system, or if applicable their respective families concerned which have a non-negligible effect on the CO2 emissions and fuel consumption related properties of the components, separate technical units or systems concerned. The application shall also be accompanied by the relevant test reports issued by an approval authority, test results, and by a statement of compliance issued by an approval authority pursuant to point 2 of Annex IV to Regulation (EU) 2018/858.
Changed in this versionArticle 17Administrative provisions for the certification of CO2 emissions and fuel consumption related properties of components, separate technical units and systems
If all the applicable requirements are met, the approval authority shall certify the values relating to the CO2 emissions and fuel consumption related properties of the component, separate technical unit and system, or if applicable their respective families concerned.
Changed in this versionIn the case referred to in paragraph 1, the approval authority shall issue a certificate on CO2 emissions and fuel consumption related properties using the model set out in:
—
Appendix 1 to Annex V as regards engines;
—
Appendix 1 to Annex VI as regards transmissions, torque converters, other torque transferring component and additional driveline components;
—
Appendix 1 to Annex VII as regards axles;
—
Appendix 1 to Annex VIII as regards air drag;
—
Appendix 1 to Annex X as regards tyres;
▼M3
—
Appendix 1 to Annex Xb as regards electric powertrain components.
▼B
Changed in this versionThe approval authority shall grant a certification number in accordance with the numbering system set out in:
—
Appendix 6 to Annex V as regards engines;
—
Appendix 7 to Annex VI as regards transmissions, torque converters, other torque transferring component and additional driveline components;
—
Appendix 5 to Annex VII as regards axles;
—
Appendix 8 to Annex VIII as regards air drag;
—
Appendix 1 to Annex X as regards tyres;
▼M3
—
Appendix 14 to Annex Xb as regards electric powertrain components. The approval authority shall not assign the same number to another component, separate technical unit and system, or if applicable their respective families. The certification number shall be used as the identifier of the test report.
Changed in this versionThe approval authority shall create a cryptographic hash of the file with test results, comprising the certification number, by means of the hashing tool referred to in Article 5(5). This hashing shall be done immediately after the test results are produced. The approval authority shall imprint that hash along with the certification number on the certificate on CO2 emissions and fuel consumption related properties.
Changed in this versionArticle 18Extension to include a new component, separate technical unit or system into a component family, separate technical unit family or system family
At the request of the manufacturer and upon approval of the approval authority, a new component, separate technical unit or system may be included as a member of a certified component family, separate technical unit family or system family if they meet the criteria for family definition set out in:
▼M3
—
Appendix 3 to Annex V as regards the family concept of engines, taking into account the requirements of Article 15(2);
▼B
—
Appendix 6 to Annex VI as regards the family concept of transmissions, torque converters, other torque transferring component and additional driveline components;
—
Appendix 4 to Annex VII as regards the family concept of axles;
—
Appendix 5 to Annex VIII as regards the family concept for the purposes of determining air drag;
▼M3
—
Appendix 13 to Annex Xb as regards the family concept of electric machine systems or integrated electric powertrain components, taking into account the requirements of Article 15(2).
▼B In such cases, the approval authority shall issue a revised certificate denoted by an extension number. The manufacturer shall modify the information document referred to in Article 16(2) and provide it to the approval authority.
Changed in this versionWhere the characteristics of the specific component, specific separate technical unit or specific system, in terms of CO2 emissions and fuel consumption related properties as determined in accordance with paragraph 1, lead to higher CO2 emissions and fuel consumption values than those of the parent component, parent separate technical unit or parent system, respectively, the new component, separate technical unit or system shall become the new parent component, separate technical unit or system.
Changed in this versionArticle 19Subsequent changes relevant for the certification of CO2 emissions and fuel consumption related properties of components, separate technical units and systems
The manufacturer shall notify the approval authority of any changes to the design or the manufacturing process of components, separate technical units or systems concerned which occur after the certification of the values relating to the CO2 emissions and fuel consumption related properties of the relevant component family, separate technical unit family or system family pursuant to Article 17 and which may have a non-negligible effect on the CO2 emissions and fuel consumption related properties of those components, separate technical units and systems.
Changed in this versionUpon receipt of the notification referred to in paragraph 1, the approval authority shall inform the manufacturer whether or not the components, separate technical units or systems affected by the changes continue to be covered by the certificate issued, or whether additional testing in accordance with Article 14 is necessary in order to verify the impact of the changes on the CO2 emissions and fuel consumption related properties of the components, separate technical units or systems concerned.
Changed in this versionWhere the components, separate technical units or systems affected by the changes are not covered by the certificate, the manufacturer shall, within one month of receipt of that information from the approval authority, apply for a new certification or an extension pursuant to Article 18. If the manufacturer does not apply for a new certification or an extension within that deadline, or if the application is rejected, the certificate shall be withdrawn.
Changed in this versionCHAPTER 5CONFORMITY OF SIMULATION TOOL OPERATION, INPUT INFORMATION AND INPUT DATA
Article 20Responsibilities of the vehicle manufacturer, the approval authority and the Commission with regard to the conformity of simulation tool operation
►M3
The vehicle manufacturer shall take the necessary measures to ensure that the processes set up for the purpose of obtaining the licence for the simulation tool for the application case covered by the licence granted pursuant to Article 7 continue to be adequate for that purpose. ◄ ►M3
For medium lorries and heavy lorries, with the exception of He-HDV or PEV, the vehicle manufacturer shall, perform the verification testing procedure set out in Annex Xa on a minimum number of vehicles in accordance with that Annex, point 3. ◄ The vehicle manufacturer shall provide, until 31 December of each year and in accordance with point 8 of Annex Xa, a test report to the approval authority for each vehicle tested, shall keep the test reports for a duration of at least 10 years and shall make them available to the Commission and approval authorities of the other Member States upon request.
Changed in this version►M3
The approval authority shall perform, four times per year, an assessment as referred to in point 2 of Annex II in order to verify whether the processes set up by the manufacturer for the purposes of determining CO2 emissions and fuel consumption for all the application cases and vehicle groups covered by the licence continue to be adequate. ◄ The assessment shall also include verification of the selection of the input information and input data and repetition of the simulations performed by the manufacturer, Where a vehicle fails the verification testing procedure set out in Annex Xa, the approval authority shall start an investigation to determine the cause of that failure, in accordance with Annex Xa. As soon as the approval authority determines the cause of the failure, it shall inform the approval authorities of the other Member States thereof. If the cause of the failure is linked to the operation of the simulation tool, Article 21 shall apply. If the cause of the failure is linked to the certified CO2 emissions and fuel consumption related properties of components, separate technical units and systems, Article 23 shall apply. If no irregularities could be found in the certification of components, separate technical units or systems and the operation of the simulation tool, the approval authority shall report the vehicle failure to the Commission. The Commission shall investigate whether the simulation tool or the verification testing procedure set out in Annex Xa has caused the vehicle to fail and whether an improvement of the simulation tool or the verification testing procedure is necessary.
Changed in this versionArticle 21Remedial measures for the conformity of simulation tool operation
Where the approval authority finds, pursuant to Article 20(2), that the processes set up by the vehicle manufacturer for the purposes of determining the CO2 emissions and fuel consumption of the vehicle groups concerned are not in accordance with the licence or with this Regulation or may lead to an incorrect determination of the CO2 emissions and fuel consumption of the vehicles concerned, the approval authority shall request the manufacturer to submit a plan of remedial measures no later than 30 calendar days after receipt of the request from the approval authority. Where the vehicle manufacturer demonstrates that further time is necessary for the submission of the plan of remedial measures, an extension of up to 30 calendar days may be granted by the approval authority.
Changed in this versionThe plan of remedial measures shall apply to all application cases and vehicle groups which have been identified by the approval authority in its request.
Changed in this versionThe approval authority shall approve or reject the plan of remedial measures within 30 calendar days of its receipt. The approval authority shall notify the manufacturer and all the other Member States of its decision to approve or reject the plan of remedial measures. The approval authority may require the vehicle manufacturer to issue a new manufacturer’s records file, vehicle information file, customer information file and certificate of conformity on the basis of a new determination of CO2 emissions and fuel consumption reflecting the changes implemented in accordance with the approved plan of remedial measures. The vehicle manufacturer shall take the necessary measures to ensure that the processes set up for the purpose of obtaining the licence to operate the simulation tool for all the application cases and vehicle groups covered by the licence granted pursuant to Article 7 continue to be adequate for that purpose. For medium lorries and heavy lorries the vehicle manufacturer shall, perform the verification testing procedure set out in Annex Xa on a minimum number of vehicles in accordance with that Annex, point 3.
Changed in this versionThe manufacturer shall be responsible for the execution of the approved plan of remedial measures.
Changed in this versionWhere the plan of the remedial measures has been rejected by the approval authority, or the approval authority establishes that the remedial measures are not being correctly applied, it shall take the necessary measures to ensure the conformity of simulation tool operation, or withdraw the licence.
Changed in this versionArticle 22Responsibilities of the manufacturer and approval authority with regards to conformity of CO2 emissions and fuel consumption related properties of components, separate technical units and systems
►M3
The manufacturer shall take the necessary measures in accordance with Annex IV to Regulation (EU) 2018/858 to ensure that the CO2 emissions and fuel consumption related properties of the components, separate technical units and systems listed in Article 12(1) which have been the subject of certification in accordance with Article 17 do not deviate from the certified values. ◄ Those measures shall also include the following:
Changed in this versionWhere CO2 emissions and fuel consumption related properties of a member of a component family, separate technical unit family or system family have been certified in accordance with Article 15(5), the reference value for the verification of the CO2 emissions and fuel consumption related properties shall be the one certified for this family member. Where a deviation from the certified values is identified as a result of the measures referred to in the first and second subparagraphs, the manufacturer shall immediately inform the approval authority thereof.
Changed in this versionThe manufacturer shall provide, on an annual basis, testing reports containing the results of the procedures referred to in the second subparagraph of paragraph 1 to the approval authority which certified the CO2 emissions and fuel consumption related properties of the component family, separate technical unit family or system family concerned. The manufacturer shall make the test reports available to the Commission upon request.
Changed in this versionThe manufacturer shall ensure that at least one in every 25 procedures referred to in the second subparagraph of paragraph 1, or, with an exception for tyres, at least one procedure per year, relating to a component, separate technical unit and system, or if applicable their respective families is supervised by a different approval authority than the one which participated in the certification of CO2 emissions and fuel consumption related properties of the component, separate technical unit, system or if applicable their respective families concerned pursuant to Article 16.
Changed in this versionAny approval authority may at any time perform verifications relating to the components, separate technical units and systems at any of the manufacturer's and vehicle manufacturer's facilities in order to verify whether the CO2 emissions and fuel consumption related properties of those components, separate technical units and systems do not deviate from the certified values. The manufacturer and the vehicle manufacturer shall provide the approval authority within 15 working days of the approval authority's request with all the relevant documents, samples and other materials in his possession and necessary to perform the verifications relating to a component, separate technical unit or system.
Changed in this versionArticle 23Remedial measures for the conformity of CO2 emissions and fuel consumption related properties of components, separate technical units and systems
Where the approval authority finds, pursuant to Articles 20 and 22, that the measures taken by the manufacturer to ensure that the CO2 emissions and fuel consumption related properties of the components, separate technical units and systems listed in Article 12(1) and which have been the subject of certification in accordance with Article 17 do not deviate from the certified values are not adequate, the approval authority shall request the manufacturer to submit a plan of remedial measures no later than 30 calendar days after receipt of the request from the approval authority. Where the manufacturer demonstrates that further time is necessary for the submission of the plan of remedial measures, an extension of up to 30 calendar days may be granted by the approval authority.
Changed in this versionThe plan of remedial measures shall apply to all the components, separate technical units and systems, or if applicable their respective families which have been identified by the approval authority in its request.
Changed in this versionThe approval authority shall approve or reject the plan of remedial measures within 30 calendar days of its receipt. The approval authority shall notify the manufacturer and all the other Member States of its decision to approve or reject the plan of remedial measures. The approval authority may require the vehicle manufacturer to issue a new manufacturer’s records file, customer information file, vehicle information file and certificate of conformity on the basis of a new determination of CO2 emissions and fuel consumption reflecting the changes implemented in accordance with the approved plan of remedial measures.
Changed in this versionThe manufacturer shall be responsible for the execution of the approved plan of remedial measures.
Changed in this versionThe manufacturer shall keep a record of every component, separate technical unit or system recalled and repaired or modified and of the workshop which performed the repair or modification. The approval authority shall have access to such records on request during the implementation of the plan of the remedial measures and for a period of 5 years after the completion of its implementation. The manufacturer shall store those records for 10 years.
Changed in this versionWhere the plan of remedial measures has been rejected by the approval authority, or the approval authority establishes that the remedial measures are not being correctly applied, it shall take the necessary measures to ensure the conformity of CO2 emissions and fuel consumption related properties of the component, separate technical unit and system, and if applicable their respective families concerned, or withdraw the certificate on CO2 emissions and fuel consumption related properties.
Changed in this versionCHAPTER 6FINAL PROVISIONS
Article 24Transitional provisions
►M3
Without prejudice to Article 10(3) of this Regulation, where the obligations referred to in Article 9 of this Regulation have not been complied with, Member States shall consider certificates of conformity for type approved vehicles to be no longer valid for the purposes of Article 48 of Regulation (EU) 2018/858, and, for type approved and individually approved vehicles, shall prohibit the registration, sale or entry into service of: ◄
▼M1
(a)
vehicles in the groups 4, 5, 9 and 10, including the sub-group ‘v’ in each vehicle group, as defined in Table 1 of Annex I, as from 1 July 2019;
▼B
(b)
vehicles in the groups 1, 2, and 3, as defined in Table 1 of Annex I, as from 1 January 2020;
(c)
vehicles in the groups 11, 12 and 16, as defined in Table 1 of Annex I, as from 1 July 2020;
▼M3
(d)
vehicles in the groups 53 and 54, as defined in Table 2 of Annex I as from 1 July 2024;
(e)
vehicles in the groups 31 to 40, as defined in Tables 4 to 6 of Annex I, as from 1 January 2025;
(f)
vehicles in the group 1s as defined in Table 1 of Annex I, as from 1 July 2024.
Changed in this versionThe obligations referred to in Article 9 shall apply as follows:
(a)
for vehicles in the groups 53 and 54, as defined in Table 2 of Annex I, with production date on or after 1 January 2024;
(b)
for vehicles in the groups P31/32, P33/34, P35/36, P37/38 and P39/40 as defined in Table 3 of Annex I with production date on or after 1 January 2024;
(c)
for heavy buses the simulation of the complete vehicle or completed vehicle as referred in point 2.1(b) of Annex I shall only be performed if the simulation of the primary vehicle as referred in point 2.1(a) of Annex I is available;
(d)
for vehicles in the group 1s as defined in Table 1 of Annex I with production date on or after 1 January 2024;
(e)
for vehicles in the groups 1, 2, 3, 4, 5, 9, 10, 4v, 5v, 9v, 10v, 11, 12, and 16, as defined in Table 1 of Annex I, other than those defined in points (f) and (g) of this paragraph, with production date on or after 1 January 2024;
(f)
for vehicles in the groups 1, 2, 3, 4, 5, 9, 10, 4v, 5v, 9v, 10v, 11, 12, and 16, as defined in Table 1 of Annex I, which are equipped with a waste heat recovery system, as defined in point 2(8) of Annex V, provided that they are not ZE-HDVs, He-HDVs or dual-fuel vehicles;
(g)
for dual-fuel vehicles in the groups 1, 2, 3, 4, 5, 9, 10, 4v, 5v, 9v, 10v, 11, 12, and 16 as defined in Table 1 of Annex I with production date on or after 1 January 2024; if they have a production date before 1 January 2024, the manufacturer may choose whether to apply Article 9. For ZE-HDVs, He-HDVs and dual-fuel vehicles in the groups 1, 2, 3, 4, 5, 9, 10, 4v, 5v, 9v, 10v, 11, 12, and 16 as defined in Table 1 of Annex I in respect of which Article 9 has not been applied in conformity with points (a) to (g) of the first subparagraph of this paragraph, the vehicle manufacturer shall determine the input parameters specified for those vehicles in the models set out in Annex III, Table 5, using the latest available version of the simulation tool referred to in Article 5(3). In such case, the obligations referred to in Article 9 shall be deemed to be fulfilled for the purposes of paragraph 1 of this Article. For the purposes of this paragraph, the production date shall mean the date of signature of the certificate of conformity and where no certificate of conformity has been issued, the date on which the vehicle identification number was affixed for the first time on the relevant parts of the vehicle.
Changed in this versionRemedial measures under Articles 21(5) and 23(6) shall apply with regard to vehicles referred to in paragraph 1, points (a), (b) and (c), of this Article pursuant to an investigation into a vehicle failure in the verification testing procedure set out in Annex Xa as from 1 July 2023 and with regard to vehicles referred to in paragraph 2, points (d) and (g), of this Article as from 1 July 2024.
Changed in this versionArticle 25Amendment to Directive 2007/46/EC
Annexes I, III, IV, IX and XV to Directive 2007/46/EC are amended in accordance with Annex XI to this Regulation.
Article 26Amendment to Regulation (EU) No 582/2011Changed
Regulation (EU) No 582/2011 is amended as follows:
In Article 3(1), the following subparagraph is added: ‘In order to receive an EC type-approval of a vehicle with an approved engine system with regard to emissions and vehicle repair and maintenance information, or an EC type-approval of a vehicle with regard to emissions and vehicle repair and maintenance information, the manufacturer shall also demonstrate that the requirements laid down in Article 6 and Annex II to Commission Regulation (EU) 2017/2400 ( *1 ) are met with respect to the vehicle group concerned. However, that requirement shall not apply where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of Regulation (EU) 2017/2400 for the respective vehicle group.
Changed in this versionArticle 8 is amended as follows:
Changed in this versionin paragraph 1a, point (d) is replaced by the following: ‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’;
Changed in this versionin paragraph 1a, the following point is added: ‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’;
Changed in this versionArticle 10 is amended as follows:
Changed in this versionin paragraph 1a, point (d) is replaced by the following: ‘(d) all other exceptions set out in points 3.1 of Annex VII to this Regulation, points 2.1 and 6.1 of Annex X to this Regulation, points 2.1, 4.1, 5.1, 7.1, 8.1 and 10.1.1 of Annex XIII to this Regulation, and point 1.1 of Appendix 6 to Annex XIII to this Regulation apply;’;
Changed in this versionin paragraph 1a, the following point is added: ‘(e) the requirements laid down in Article 6 and Annex II to Regulation (EU) 2017/2400 are met with respect to the vehicle group concerned, except where the manufacturer indicates that new vehicles of the type to be approved will not be registered, sold or put into service in the Union on or after the dates laid down in points (a), (b) and (c) of paragraph 1 of Article 24 of that Regulation for the respective vehicle group.’.
Changed in this versionArticle 27Entry into force
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union. This Regulation shall be binding in its entirety and directly applicable in all Member States.
ANNEX I — CLASSIFICATION OF VEHICLES IN VEHICLE GROUPS AND METHOD TO DETERMINE CO2 EMISSIONS AND FUEL CONSUMPTION FOR HEAVY BUSES
1. Classification of the vehicles for the purpose of this Regulation
Classification of vehicles of category M
Changed in this versionHeavy buses
Changed in this versionClassification of primary vehicles Table 3 Vehicle groups for primary vehicles
| Description of elements relevant to the classification in vehicle groups | Vehicle group (1) | Allocation of generic body | Vehicle sub-group | Allocation of mission profile | |||||
|---|---|---|---|---|---|---|---|---|---|
| Number of axles | Artic-ulated | Low floor (LF) / High floor (HF) (2) | Number of decks (3) | Heavy Urban | Urban | Suburban | Interurban | Coach | |
| 2 | no | P31/32 | LF | SD | P31 SD | x | x | x | x |
| DD | P31 DD | x | x | x | |||||
| HF | SD | P32 SD | x | x | |||||
| DD | P32 DD | x | x | ||||||
| 3 | no | P33/34 | LF | SD | P33 SD | x | x | x | x |
| DD | P33 DD | x | x | x | |||||
| HF | SD | P34 SD | x | x | |||||
| DD | P34 DD | x | x | ||||||
| yes | P35/36 | LF | SD | P35 SD | x | x | x | x | |
| DD | P35 DD | x | x | x | |||||
| HF | SD | P36 SD | x | x | |||||
| DD | P36 DD | x | x | ||||||
| 4 | no | P37/38 | LF | SD | P37 SD | x | x | x | x |
| DD | P37 DD | x | x | x | |||||
| HF | SD | P38 SD | x | x | |||||
| DD | P38 DD | x | x | ||||||
| yes | P39/40 | LF | SD | P39 SD | x | x | x | x | |
| DD | P39 DD | x | x | x | |||||
| HF | SD | P40 SD | x | x | |||||
| DD | P40 DD | x | x |
(1) ‘P’ indicates the primary stage of the classification; the two numbers separated by the slash indicate the numbers for vehicle groups the vehicle can be allocated in the complete or completed stage.
(2) ‘Low floor’ means vehicle codes ‘CE’, ‘CF’, ‘CG’, ‘CH’, as set out in point 3 of part C of Annex I to Regulation (EU) 2018/858.
‘High floor’ means vehicle codes ‘CA’, ‘CB’, ‘CC’, ‘CD’, as set out in point 3 of part C of Annex I to Regulation (EU) 2018/858.
(3) ‘SD’ means single deck vehicle, ‘DD’ means double deck.
Changed in this versionClassification of complete vehicles or completed vehicles The classification of complete or completed vehicles that are heavy buses is based on the following six criteria:
Changed in this versionNumber of axles;
Changed in this versionVehicle code as set out in Annex I, part C, point 3, to Regulation (EU) 2018/858;
Changed in this versionClass of vehicle in accordance with paragraph 2 of UN Regulation No. 107 ( 2 );
Changed in this versionLow entry vehicle (‘yes/no’ information derived from vehicle code and type of axle) to be determined according the decision flow shown in Figure 1;
Changed in this versionNumber of passengers in lower deck from the Certificate of Conformity as set out in Annex VIII to Commission Implementing Regulation (EU) 2020/683 ( 3 ) or equivalent documents in the case of individual vehicle approval;
Changed in this versionHeight of the integrated body to be determined in accordance with Annex VIII. Figure 1
Decision flow to determine whether a vehicle is ‘low entry’ or not: The corresponding classification to be used is given in Tables 4, 5 and 6. Table 4 Vehicle groups for complete vehicles and completed vehicles that are heavy buses with 2 axles
| Description of elements relevant to the classification in vehicle groups | Vehicle group | Allocation of |
mission profile
| Number of Axles | Chassis configuration | ||
|---|---|---|---|
| (explanation only) | Vehicle Code (*1) | Class of vehicle (*2) | Low Entry |
| (Vehicle Code CE or CG only) | Passenger seats in lower deck (Vehicle Code CB or CD only) | Height of the integrated body in [mm] (Vehicles Class ‘II+III’ only) | |
| I | I |
+II or
| A | II | II |
| +III | III |
or
| B | Heavy Urban | Urban | Suburban | Interurban | Coach | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | rigid | LF | SD | CE | x | x | x | no | — | — | 31a | x | x | x |
| x | x | yes | — | — | 31b1 | x | x | x | ||||||
| x | yes | — | — | 31b2 | x | x | x | x | ||||||
| DD | CF | x | x | x | — | — | — | 31c | x | x | x | |||
| open top | SD | CI | x | x | x | x | x | — | — | — | 31d | x | x | x |
| DD | CJ | x | x | x | x | x | — | — | — | 31e | x | x | x | |
| HF | SD | CA | x | — | — | — | 32a | x | x | |||||
| x | — | — | ≤ 3 100 | 32b | x | x | ||||||||
| x | — | — | > 3 100 | 32c | x | x | ||||||||
| x | — | — | — | 32d | x | x | ||||||||
| DD | CB | x | x | x | — | ≤ 6 | — | 32e | x | x | ||||
| x | x | x | — | > 6 | — | 32f | x | x |
(*1) In accordance with Regulation (EU) 2018/858.
(*2) In accordance with paragraph 2 of UN Regulation No. 107. Table 5 Vehicle groups for complete vehicles and completed vehicles that are heavy buses with 3 axles
| Description of elements relevant to the classification in vehicle groups | Vehicle group | Allocation of |
mission profile
| Number of Axles | Chassis configuration | ||
|---|---|---|---|
| (explanation only) | Vehicle Code (*1) | Class of vehicle (*2) | Low Entry |
| (Vehicle Code CE or CG only) | Passenger seats in lower deck (Vehicle Code CB or CD only) | Height of the integrated body in [mm] (Vehicles Class ‘II+III’ only) | |
| I | I |
+II or
| A | II | II |
| + III | III |
or
| B | Heavy Urban | Urban | Suburban | Interurban | Coach | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | rigid | LF | SD | CE | x | x | x | no | — | — | 33a | x | x | x |
| x | x | yes | — | — | 33b1 | x | x | x | ||||||
| x | yes | — | — | 33b2 | x | x | x | x | ||||||
| DD | CF | x | x | x | — | — | — | 33c | x | x | x | |||
| open top | SD | CI | x | x | x | x | x | — | — | — | 33d | x | x | x |
| DD | CJ | x | x | x | x | x | — | — | — | 33e | x | x | x | |
| HF | SD | CA | x | — | — | — | 34a | x | x | |||||
| x | — | — | ≤ 3 100 | 34b | x | x | ||||||||
| x | — | — | > 3 100 | 34c | x | x | ||||||||
| x | — | — | — | 34d | x | x | ||||||||
| DD | CB | x | x | x | — | ≤ 6 | — | 34e | x | x | ||||
| x | x | x | — | > 6 | — | 34f | x | x | ||||||
| articu-lated | LF | SD | CG | x | x | x | no | — | — | 35a | x | x | x | |
| x | x | yes | — | — | 35b1 | x | x | x | ||||||
| x | yes | — | — | 35b2 | x | x | x | x | ||||||
| DD | CH | x | x | x | — | — | — | 35c | x | x | x | |||
| HF | SD | CC | x | — | — | — | 36a | x | x | |||||
| x | — | — | ≤ 3 100 | 36b | x | x | ||||||||
| SD | x | — | — | > 3 100 | 36c | x | x | |||||||
| x | — | — | — | 36d | x | x | ||||||||
| DD | CD | x | x | x | — | ≤ 6 | — | 36e | x | x | ||||
| x | x | x | — | > 6 | — | 36f | x | x |
(*1) In accordance with Regulation (EU) 2018/858.
(*2) In accordance with paragraph 2 of UN Regulation No. 107. Table 6 Vehicle groups for complete vehicles and completed vehicles that are heavy buses with 4 axles
| Description of elements relevant to the classification in vehicle groups | Vehicle group | Allocation of |
mission profile
| Number of Axles | Chassis configuration | ||
|---|---|---|---|
| (explanation only) | Vehicle Code (*1) | Class of vehicle (*2) | Low Entry |
| (Vehicle Code CE or CG only) | Passenger seats in lower deck (Vehicle Code CB or CD only) | Height of the integrated body in [mm] (Vehicles Class ‘II+III’ only) | |
| I | I |
+II or
| A | II | II |
| +III | III |
or
| B | Heavy Urban | Urban | Suburban | Interurban | Coach | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | rigid | LF | SD | CE | x | x | x | no | — | — | 37a | x | x | x |
| x | x | yes | — | — | 37b1 | x | x | x | ||||||
| x | yes | — | — | 37b2 | x | x | x | x | ||||||
| DD | CF | x | x | x | — | — | — | 37c | x | x | x | |||
| open top | SD | CI | x | x | x | x | x | — | — | — | 37d | x | x | x |
| DD | CJ | x | x | x | x | x | — | — | — | 37e | x | x | x | |
| HF | SD | CA | x | — | — | — | 38a | x | x | |||||
| x | — | — | ≤ 3 100 | 38b | x | x | ||||||||
| x | — | — | > 3 100 | 38c | x | x | ||||||||
| x | — | — | — | 38d | x | x | ||||||||
| DD | CB | x | x | x | — | ≤ 6 | — | 38e | x | x | ||||
| x | x | x | — | > 6 | — | 38f | x | x | ||||||
| articu-lated | LF | SD | CG | x | x | x | no | — | — | 39a | x | x | x | |
| x | x | yes | — | — | 39b1 | x | x | x | ||||||
| x | yes | — | — | 39b2 | x | x | x | x | ||||||
| DD | CH | x | x | x | — | — | — | 39c | x | x | x | |||
| HF | SD | CC | x | — | — | — | 40a | x | x | |||||
| x | — | — | ≤ 3 100 | 40b | x | x | ||||||||
| SD | x | — | — | > 3 100 | 40c | x | x | |||||||
| x | — | — | — | 40d | x | x | ||||||||
| DD | CD | x | x | x | — | ≤ 6 | — | 40e | x | x | ||||
| x | x | x | — | > 6 | — | 40f | x | x |
(*1) In accordance with Regulation (EU) 2018/858.
(*2) In accordance with paragraph 2 of UN Regulation No. 107.
Changed in this version2. Method to determine CO2 emissions and fuel consumption for heavy buses
For heavy buses the vehicle specifications of the complete vehicle or completed vehicle including properties of the final bodywork and auxiliary units shall be reflected in the results for CO2 emissions and fuel consumption. In the case of heavy buses built in steps, more than a single manufacturer may be involved in the process of generation of input data and input information and the operation of the simulation tool. For heavy buses the CO2 emissions and fuel consumption shall be based on the following two different simulations:
Changed in this versionfor the primary vehicle;
Changed in this versionfor the complete vehicle or completed vehicle.
Changed in this versionIf a heavy bus is approved by a manufacturer as a complete vehicle, the simulations shall be performed for both the primary vehicle and the complete vehicle.
Changed in this versionFor the primary vehicle the input to the simulation tool covers input data regarding the engine, transmission, tyres and input information for a subset of auxiliary units ( 4 ). The classification into vehicle groups is performed in accordance with Table 3 based on the number of axles and the information whether the vehicle is an articulated bus or not. In the simulations for the primary vehicle the simulation tool allocates a set of four different generic bodies (high floor and low floor, single deck and double deck bodywork) and simulates the 11 mission profiles as listed in Table 3 for each vehicle group for two different loading conditions. This leads to a set of 22 results for CO2 emissions and fuel consumption for a primary heavy bus. The simulation tool produces the vehicle information file for the initial step (VIF1), which contains all necessary data to be handed over to the subsequent manufacturing step. The VIF1 comprises all non-confidential input data, the results for energy consumption ( 5 ) in [MJ/km], information on the primary manufacturer and the relevant hashes ( 6 ).
Changed in this versionThe manufacturer of the primary vehicle shall make the VIF1 available to the manufacturer responsible for the subsequent manufacturing step. Where a manufacturer of a primary vehicle provides data going beyond the primary vehicle requirements as set out in Annex III, this data does not influence the simulation results for the primary vehicle but is written into the VIF1 to be considered in later steps. For a primary vehicle the simulation tool furthermore produces a manufacturer’s records file.
Changed in this versionIn the case of an interim vehicle, the interim manufacturer is responsible for a sub-set of relevant input data and input information for the final bodywork ( 7 ). An interim manufacturer does not apply for certification of the completed vehicle. An interim manufacturer shall add or update information relevant for the completed vehicle and operate the simulation tool to produce an updated and hashed version of the vehicle information file (VIFi) ( 8 ). The VIFi shall be made available to the manufacturer responsible for the subsequent manufacturing step. For interim vehicles the VIFi also covers the task of documentation towards approval authorities. No simulations of CO2 emissions and/or fuel consumption are performed on interim vehicles.
Changed in this versionIf a manufacturer performs modifications to an interim, complete or completed vehicle, which would require updates to the input data or the input information allocated to the primary vehicle (e.g. a change of an axle or of tyres), the manufacturer performing the modification acts as a primary vehicle manufacturer with the corresponding responsibilities.
Changed in this versionFor a complete or completed vehicle the manufacturer shall complement and, if necessary, update the input data and input information for the final bodywork as transmitted in the VIFi from the previous manufacturing step and shall operate the simulation tool to calculate the CO2 emissions and fuel consumption. For the simulations at this stage, heavy buses are classified based on the six criteria set out in point 1.2.3 into the vehicle groups as listed in Tables 4, 5 and 6. To determine CO2 emissions and fuel consumption of complete vehicles or completed vehicles that are heavy buses the simulation tool performs the following calculation steps: Step 1 - Selection of the primary vehicle sub-group which matches the bodywork of the complete or completed vehicle (e.g. ‘P34 DD’ for ‘34f’) and making available the corresponding results for energy consumption from the primary vehicle simulation. Step 2 - Performing simulations to quantify the influence of the bodywork and auxiliaries of the complete vehicle or completed vehicle compared to the generic bodywork and auxiliaries, as considered in the simulations for the primary vehicle regarding energy consumption. In these simulations, generic data are used for the set of primary vehicle data, which are not part of the information transfer between different manufacturing steps as provided by the VIF ( 9 ). Step 3 - Combining energy consumption results from the primary vehicle simulation as made available by step 1 with the results from step 2 provides the energy consumption results of the complete or completed vehicle. The details of this calculation step are documented in the user manual of the simulation tool. Step 4 - Results for CO2 emissions and fuel consumption of the vehicle are calculated based on the results of step 3 and the generic fuel specifications as stored in the simulation tool. Steps 2, 3 and 4 are performed separately for each combination of mission profile as listed in the Tables 4, 5 and 6 for the vehicle groups in both low and representative loading condition. For a complete vehicle or completed vehicle the simulation tool produces a manufacturer’s records file, a customer information file as well as a VIFi. The VIFi shall be made available to the subsequent manufacturer in the event the vehicle undergoes a further step to be completed. Figure 2 shows the data flow based on the example of a vehicle produced in five CO2 related manufacturing steps. Figure 2
Example of data flow in the case of a heavy bus manufactured in five steps
Changed in this versionANNEX II
REQUIREMENTS AND PROCEDURES RELATED TO THE OPERATION OF THE SIMULATION TOOL
1. The processes to be set up by the vehicle manufacturer with a view to the operation of the simulation tool
The manufacturer shall set up at least the following processes: A data management system covering sourcing, storing, handling and retrieving of the input information and input data for the simulation tool as well as handling certificates on the CO2 emissions and fuel consumption related properties of a component families, separate technical unit families and system families. The data management system shall at least:
Changed in this versionensure application of correct input information and input data to specific vehicle configurations
Changed in this versionensure correct calculation and application of standard values;
Changed in this versionverify by means of comparing cryptographic hashes that the input files of components, separate technical units, systems or if applicable their respective families, which are used for the simulation corresponds to the input data of the component, separate technical unit, system or if applicable their respective family for which the certification has been granted;
Changed in this versioninclude a protected database for storing the input data relating to the component families, separate technical unit families or system families and the corresponding certificates of the CO2 emissions and fuel consumption related properties;
Changed in this versionensure correct management of the changes of specification and updates of components, separate technical units and systems;
Changed in this versionenable tracing of the components, separate technical units and systems after the vehicle is produced. A data management system covering retrieving of the input information and input data and calculations by means of the simulation tool and storing of the output data. The data management system shall at least:
Changed in this versionensure a correct application of cryptographic hashes;
Changed in this versioninclude a protected database for storing the output data; Process for consulting the dedicated electronic distribution platform referred to in Article 5(2) and Article 10(1) and (2), as well as downloading and installing the latest versions of the simulation tool. Appropriate training of staff working with the simulation tool.
Changed in this version2. Assessment by the approval authority
The approval authority shall verify whether the processes set out in point 1 related to the operation of the simulation tool have been set up. The approval authority shall also verify the following:
Changed in this versionthe functioning of the processes set out in points 1.1.1, 1.1.2 and 1.1.3 and the application of the requirement set out in point 1.1.4;
Changed in this versionthat the processes used during the demonstration are applied in the same manner in all the production facilities manufacturing vehicles belonging to the application case concerned;
Changed in this versionthe completeness of the description of the data and process flows of operations related to the determination of the CO2 emissions and fuel consumption of the vehicles. For the purpose of the second paragraph, point (a), the verification shall include determination of the CO2 emissions and fuel consumption of at least one vehicle from each production facility for which the licence has been applied for.
Changed in this versionAppendix 1
MODEL OF AN INFORMATION DOCUMENT FOR THE PURPOSES OF OPERATING THE SIMULATION TOOL WITH A VIEW TO DETERMINING THE CO2 EMISSIONS AND FUEL CONSUMPTION OF NEW VEHICLES
SECTION I
SECTION II
1. Additional information
Appendix 2
MODEL OF A LICENCE TO OPERATE THE SIMULATION TOOL WITH A VIEW TO DETERMINING CO2 EMISSIONS AND FUEL CONSUMPTION OF NEW VEHICLES
Maximum format: A4 (210 × 297 mm)
LICENCE TO OPERATE THE SIMULATION TOOL WITH A VIEW TO DETERMINING CO2 EMISSIONS AND FUEL CONSUMPTION OF NEW VEHICLES
SECTION I
SECTION II
1. Additional information
ANNEX III
INPUT INFORMATION RELATING TO THE CHARACTERISTIC OF THE VEHICLE
1. Introduction
2. Definitions
‘parameter ID’: Unique identifier as used in the simulation tool for a specific input parameter or set of input data.
Changed in this version‘type’: Data type of the parameter
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format:YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’ |
| integer … | value with an integral data type, no leading zeros, e.g. ‘1 800 ’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2 345,67 ’; for ‘double, 4’: ‘45.6780’. |
‘unit’ … physical unit of the parameter.
Changed in this version‘corrected actual mass of the vehicle’ means the mass as specified under the ‘actual mass of the vehicle’ in accordance with Commission Regulation (EU) No 1230/2012 (*) with an exception for the tank(s) which shall be filled to at least 50 % of its or their capacity/ies. The liquid containing systems are filled to 100 % of the capacity specified by the manufacturer, except the liquid containing systems for waste water that must remain empty. For medium rigid lorries, heavy rigid lorries and tractors the mass is determined without superstructure and corrected by the additional weight of the non-installed standard equipment as specified in point 4.3. The mass of a standard body, standard semi-trailer or standard trailer to simulate the complete vehicle or complete vehicle-(semi-)trailer combination are added automatically by the simulation tool. All parts that are mounted on and above the main frame are regarded as superstructure parts if they are installed only for facilitating a superstructure, independent of the necessary parts for in running order conditions. For heavy buses that are primary vehicles ‘corrected actual mass of the vehicle’ is not applicable as the generic mass value is allocated by the simulation tool.
Changed in this version‘height of the integrated body’ means the difference in ‘Z’-direction between the reference point ‘A’ of the highest point and lowest point ‘B’ of an integrated body (see Figure 1). For vehicles deviating from the standard case, the following cases are applicable (see Figure 2):
Changed in this versionFor all other cases not covered by standard or special cases 1 to 4, the height of the integrated body is the difference between the highest point of the vehicle and point B. This parameter is relevant only for heavy buses. Figure 1
Height of the integrated body – standard case
Figure 2
Height of the integrated body – special cases
Changed in this versionreference point ‘A’ means the highest point on the bodywork (Figure 1). Body and/or design panels, brackets for mounting e.g. HVAC systems, hatches and similar items shall not be considered.
Changed in this versionreference point ‘B’ means the lowest point on the lower outside edge of the bodywork (Figure 1). Brackets e.g. for axle mounting shall not be considered.
Changed in this version‘vehicle length’ means the vehicle dimension in accordance with Table I of Appendix 1 of Annex I to Regulation (EU) 1230/2012. Additionally, removable load carrier devices, non-removable coupling devices and any other non-removable exterior parts which do not affect the usable space for passengers shall not be taken into account. This parameter is relevant only for heavy buses.
Changed in this version‘vehicle width’ means the vehicle dimension in accordance with Table II of Appendix 1 of Annex I to Regulation (EU) 1230/2012. Deviating from these provisions and not to be considered are removable load carrier devices, non-removable coupling devices and any other non-removable exterior parts which do not affect the usable space for passengers.
Changed in this version‘entrance height in non-kneeled position’ means the floor level within the first door aperture above the ground, measured at the most forward door of the vehicle when the vehicle is in non-kneeled position.
Changed in this version‘fuel cell’ means an energy converter transforming chemical energy (input) into electrical energy (output) or vice versa.
Changed in this version‘fuel cell vehicle’ or ‘FCV’ means a vehicle equipped with a powertrain containing exclusively fuel cell(s) and electric machine(s) as propulsion energy converter(s).
Changed in this version‘fuel cell hybrid vehicle’ or ‘FCHV’ means a fuel cell vehicle equipped with a powertrain containing at least one fuel storage system and at least one rechargeable electric energy storage system as propulsion energy storage systems.
Changed in this version‘pure ICE vehicle’ means a vehicle where all of the propulsion energy converters are internal combustion engines.
Changed in this version‘electric machine’ or ‘EM’ means an energy converter transforming between electrical and mechanical energy.
Changed in this version‘energy storage system’ means a system which stores energy and releases it in the same form as was input.
Changed in this version‘propulsion energy storage system’ means an energy storage system of the powertrain which is not a peripheral device and whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
Changed in this version‘category of propulsion energy storage system’ means a fuel storage system, a rechargeable electric energy storage system (REESS), or a rechargeable mechanical energy storage system.
Changed in this version‘downstream’ means a position in the vehicle’s powertrain that is closer to the wheels than the actual reference position.
Changed in this version‘drivetrain’ means the connected elements of the powertrain for transmission of the mechanical energy between the propulsion energy converter(s) and the wheels.
Changed in this version‘energy converter’ means a system where the form of energy output is different from the form of energy input.
Changed in this version‘propulsion energy converter’ means an energy converter of the powertrain which is not a peripheral device whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
Changed in this version‘category of propulsion energy converter’ means an internal combustion engine, an electric machine, or a fuel cell.
Changed in this version‘form of energy’ means electrical energy, mechanical energy, or chemical energy (including fuels).
Changed in this version‘fuel storage system’ means a propulsion energy storage system that stores chemical energy as liquid or gaseous fuel.
Changed in this version‘hybrid vehicle’ or ‘HV’ means a vehicle equipped with a powertrain containing at least two different categories of propulsion energy converters and at least two different categories of propulsion energy storage systems.
Changed in this version‘hybrid electric vehicle’ or ‘HEV’ means a hybrid vehicle where one of the propulsion energy converters is an electric machine and the other one is an internal combustion engine.
Changed in this version‘serial HEV’ means a HEV with a powertrain architecture where the ICE powers one or more electrical energy conversion paths with no mechanical connection between the ICE and the wheels of the vehicle.
Changed in this version‘internal combustion engine’ or ‘ICE’ means an energy converter with intermittent or continuous oxidation of combustible fuel transforming between chemical and mechanical energy.
Changed in this version‘off-vehicle charging hybrid electric vehicle’ or ‘OVC-HEV’ means a hybrid electric vehicle that can be charged from an external source.
Changed in this version‘parallel HEV’ means a HEV with a powertrain architecture where the ICE powers only a single mechanically connected path between the engine and the wheels of the vehicle.
Changed in this version‘peripheral devices’ means any energy consuming, converting, storing or supplying devices, where the energy is not directly or indirectly used for the purpose of vehicle propulsion but which are essential to the operation of the powertrain.
Changed in this version‘powertrain’ means the total combination in a vehicle of propulsion energy storage system(s), propulsion energy converter(s) and the drivetrain(s) providing the mechanical energy at the wheels for the purpose of vehicle propulsion, plus peripheral devices.
Changed in this version‘pure electric vehicle’ or ‘PEV’ means a motor vehicle pursuant to Regulation (EU) 2018/858, article 3(16), equipped with a powertrain containing exclusively electric machines as propulsion energy converters and exclusively rechargeable electric energy storage systems as propulsion energy storage systems and/or alternatively any other means for direct conductive or inductive supply of electric energy from the power network providing the propulsion energy to the motor vehicle.
Changed in this version‘upstream’ means a position in the vehicle’s powertrain that is further away from the wheels than the actual reference position.
Changed in this version‘IEPC’ means an integrated electric powertrain component in accordance with point 2(36) of Annex Xb.
Changed in this version‘IHPC Type 1’ means an integrated hybrid electric vehicle powertrain component Type 1 in accordance with point 2(38) of Annex Xb.
Changed in this version3. Set of input parameters
Table 1 Input parameters ‘Vehicle/General’
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| Manufacturer | P235 | Token | [-] | X | X | X | X | |
| Manufacturer Address | P252 | Token | [-] | X | X | X | X | |
| Model_CommercialName | P236 | Token | [-] | X | X | X | X | |
| VIN | P238 | Token | [-] | X | X | X | X | |
| Date | P239 | Date Time | [-] | Date and time when input information and input data is created | X | X | X | X |
| Legislative Category | P251 | String | [-] | Allowed values: ‘N2’, ‘N3’,‘M3’ | X | X | X | X |
| ChassisConfiguration | P036 | String | [-] | Allowed values: ‘Rigid Lorry’, ‘Tractor’, ‘Van’, ‘Bus’ | X | X | X | |
| AxleConfiguration | P037 | String | [-] | Allowed values: ‘4 × 2’, ‘4 × 2F’, ‘6 × 2’, ‘6 × 4’, ‘8 × 2’, ‘8 × 4’where ‘4 × 2F’ refers to 4 × 2 vehicles with a driven front axle | X | X | X | |
| Articulated | P281 | boolean | In accordance with Article 3, point (37) | X | ||||
| CorrectedActualMass | P038 | Int | [kg] | In accordance with ‘Corrected actual mass of the vehicle’ as specified in point 2(4) | X | X | X | |
| TechnicalPermissibleMaximumLadenMass | P041 | int | [kg] | In accordance with Article 2, point (7) of Regulation (EU) No 1230/2012 | X | X | X | X |
| IdlingSpeed | P198 | int | [1/min] | In accordance with point 7.1 | ||||
| For PEV no input is required. | X | X | X | |||||
| RetarderType | P052 | string | [-] | Allowed values: ‘None’, ‘Losses included in Gearbox’, ‘Engine Retarder’, ‘Transmission Input Retarder’, ‘Transmission Output Retarder’, ‘Axlegear Input Retarder’ | ||||
| ‘Axlegear Input Retarder’ is applicable only for powertrain architectures ‘E3’, ‘S3’, ‘S-IEPC’ and ‘E-IEPC’ | X | X | X | |||||
| RetarderRatio | P053 | double, 3 | [-] | Step-up ratio in accordance with table 2 of Annex VI | X | X | X | |
| AngledriveType | P180 | string | [-] | Allowed values: ‘None’, ‘Losses included in Gearbox’, ‘Separate Angledrive’ | X | X | X | |
| PTOShafts GearWheels (1) | P247 | string | [-] | Allowed values: ‘none’, ‘only the drive shaft of the PTO’, ‘drive shaft and/or up to 2 gear wheels’, ‘drive shaft and/or more than 2 gear wheels’, ‘only one engaged gearwheel above oil level’ , ‘PTO which includes 1 or more additional gearmesh(es), without disconnect clutch’ | X | |||
| PTOOther Elements (1) | P248 | string | [-] | Allowed values: ‘none’, ‘shift claw, synchroniser, sliding gearwheel’, ‘multi-disc clutch’, ‘multi-disc clutch, oil pump’ | X | |||
| CertificationNumberEngine | P261 | token | [-] | Only applicable if the component is present in the vehicle | X | X | X | |
| CertificationNumberGearbox | P262 | token | [-] | Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |
| CertificationNumberTorqueconverter | P263 | token | [-] | Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |
| CertificationNumberAxlegear | P264 | token | [-] | Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |
| CertificationNumberAngledrive | P265 | token | [-] | Refers to certified ADC component installed in the angle drive position. | ||||
| Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |||||
| CertificationNumberRetarder | P266 | token | [-] | Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |
| Certification NumberAirdrag | P268 | token | [-] | Only applicable if certified input data is provided | X | X | X | |
| AirdragModifiedMultistage | P334 | boolean | [-] | Input required for all manufacturing stages subsequent to a first entry to the air drag component. | ||||
| If parameter is set to ‘true’ w/o providing a certified air drag component, the simulation tool applies standard values according to Annex VIII. | X | |||||||
| Certification NumberIEPC | P351 | token | [-] | Only applicable if the component is present in the vehicle and certified input data is provided | X | X | X | |
| ZeroEmissionVehicle | P269 | boolean | [-] | As defined in Article 3, point (15) | X | X | X | |
| VocationalVehicle | P270 | boolean | [-] | In accordance with Article 3, point (9) of Regulation (EU) 2019/1242 | X | |||
| NgTankSystem | P275 | string | [-] | Allowed values: ‘Compressed’, ‘Liquefied’ |
Only relevant for vehicles with engines of fuel type ‘NG PI’ and ‘NG CI’ (P193)
| Where both tank systems are present on a vehicle, the system which is able to contain the higher amount of fuel energy shall be declared as input to the simulation tool. | X | X | X | ||
|---|---|---|---|---|---|
| Sleepercab | P276 | boolean | [-] | X | |
| ClassBus | P282 | string | [-] | Allowed values: ‘I’, ‘I+II’, ‘A’, ‘II’, ‘II+III’, ‘III’, ‘B’ in accordance with paragraph 2 of UN Regulation No. 107 | X |
| NumberPassengersSeatsLowerDeck | P283 | int | [-] | Number of passenger seats - excluding driver and crew seats. | |
| In the case of a double deck vehicle, this parameter shall be used to declare the passenger seats from the lower deck. In the case of a single deck vehicle, this parameter shall be used to declare the number of total passenger seats. | X | ||||
| NumberPassengersStandingLowerDeck | P354 | int | [-] | Number of registered standing passengers | |
| In the case of a double deck vehicle, this parameter shall be used to declare the registered standing passengers from the lower deck. In the case of a single deck vehicle, this parameter shall be used to declare the total number of registered standing passengers. | X | ||||
| NumberPassengersSeatsUpperDeck | P284 | int | [-] | Number of passenger seats - excluding driver and crew seats of the upper deck in a double deck vehicle. | |
| For single deck vehicles ‘0’ shall be provided as input. | X | ||||
| NumberPassengersStandingUpperDeck | P355 | int | [-] | Number of registered standing passengers of the upper deck in a double deck vehicle. | |
| For single deck vehicles ‘0’ shall be provided as input. | X | ||||
| BodyworkCode | P285 | int | [-] | Allowed values: ‘CA’, ‘CB’, ‘CC’, ‘CD’, ‘CE’, ‘CF’, ‘CG’, ‘CH’, ‘CI’, ‘CJ’ in accordance with point 3 of part C of Annex I to Regulation (EU) 2018/585. | |
| In the case of bus chassis with vehicle code CX, no input shall be delivered. | X | ||||
| LowEntry | P286 | boolean | [-] | ‘low entry’ in accordance with point 1.2.2.3 of Annex I | X |
| HeightIntegratedBody | P287 | int | [mm] | in accordance with point 2(5) | X |
| VehicleLength | P288 | int | [mm] | in accordance with point 2(8) | X |
| VehicleWidth | P289 | int | [mm] | in accordance with point 2(9) | X |
| EntranceHeight | P290 | int | [mm] | in accordance with point 2(10) | X |
| DoorDriveTechnology | P291 | string | [-] | Allowed values: ‘pneumatic’, ‘electric’, ‘mixed’ | X |
| Cargo volume | P292 | double, 3 | [m3] | Only relevant to vehicles of chassis configuration ‘van’ | X |
| VehicleDeclarationType | P293 | string | [-] | Allowed values: ‘interim’, ‘final’ | X |
| VehicleTypeApprovalNumber | P352 | token | [-] | Whole vehicle type approval number | |
| In the case of individual vehicle approvals, the individual vehicle approval number | X | X | X |
(1) In the event multiple PTOs are mounted to the transmission, only the component with the highest losses according to point 3.6 of Annex IX, for its combination of criteria ‘PTOShaftsGearWheels’ and ‘PTOShaftsOtherElements’, shall be declared. Table 2 Input parameters ‘Vehicle/AxleConfiguration’ per wheel axle
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| Twin Tyres | P045 | boolean | [-] | X | X | X | ||
| Axle Type | P154 | String | [-] | Allowed values: ‘VehicleNonDriven’, ‘VehicleDriven’ | X | X | X | |
| Steered | P195 | boolean | Only active steered axles shall be declared as ‘steered’ | X | X | X | ||
| Certification NumberTyre | P267 | token | [-] | X | X | X |
Tables 3 and 3a provide the lists for input parameters regarding auxiliary units. The technical definitions for determining these parameters are given in Annex IX. The parameter ID is used to provide a clear reference between the parameters of Annexes III and IX. Table 3 Input parameters ‘Vehicle/Auxiliaries’ for medium lorries and heavy lorries
| Parameter name | Parameter ID | Type | Unit | Description/Reference |
|---|---|---|---|---|
| EngineCoolingFan/Technology | P181 | string | [-] | Allowed values: ‘Crankshaft mounted - Electronically controlled visco clutch’, ‘Crankshaft mounted - Bimetallic controlled visco clutch’, ‘Crankshaft mounted - Discrete step clutch’, ‘Crankshaft mounted - On/off clutch’, ‘Belt driven or driven via transmission - Electronically controlled visco clutch’, ‘Belt driven or driven via transmission - Bimetallic controlled visco clutch’, ‘Belt driven or driven via transmission - Discrete step clutch’, ‘Belt driven or driven via transmission - On/off clutch’, ‘Hydraulic driven - Variable displacement pump’, ‘Hydraulic driven - Constant displacement pump’, ‘Electrically driven - Electronically controlled’ |
| SteeringPump/Technology | P182 | string | [-] | Allowed values: ‘Fixed displacement’, ‘Fixed displacement with elec. control’, ‘Dual displacement’, ‘Dual displacement with elec. control’‘Variable displacement mech. controlled’, ‘Variable displacement elec. controlled’, ‘Electric driven pump’, ‘Full electric steering gear’ |
For PEV or HEV with a powertrain configuration ‘S’ or ‘S-IEPC’ in accordance with point 10.1.1 ‘Electric driven pump’ or ‘Full electric steering gear’ are the only allowed values. Separate entry for each active steered wheel axle required.
| ElectricSystem/Technology | P183 | string | [-] | Allowed values: ‘Standard technology’, ‘Standard technology - LED headlights, all’; |
| PneumaticSystem/Technology | P184 | string | [-] | Allowed values: ‘Small’, ‘Small + ESS’, ‘Small + visco clutch’, ‘Small + mech. clutch’, ‘Small + ESS + AMS’, ‘Small + visco clutch + AMS’, ‘Small + mech. clutch + AMS’, ‘Medium Supply 1-stage’, ‘Medium Supply 1-stage + ESS’, ‘Medium Supply 1-stage + visco clutch ’, ‘Medium Supply 1-stage + mech. clutch’, ‘Medium Supply 1-stage + ESS + AMS’, ‘Medium Supply 1-stage + visco clutch + AMS’, ‘Medium Supply 1-stage + mech. clutch + AMS’, ‘Medium Supply 2-stage’, ‘Medium Supply 2-stage + ESS’, ‘Medium Supply 2-stage + visco clutch ’, ‘Medium Supply 2-stage + mech. clutch’, ‘Medium Supply 2-stage + ESS + AMS’, ‘Medium Supply 2-stage + visco clutch + AMS’, ‘Medium Supply 2-stage + mech. clutch + AMS’, ‘Large Supply’, ‘Large Supply + ESS’, ‘Large Supply + visco clutch’, ‘Large Supply + mech. clutch’, ‘Large Supply + ESS + AMS’, ‘Large Supply + visco clutch + AMS’, ‘Large Supply + mech. clutch + AMS’, ‘Vacuum pump’, ‘Small + elec. driven’, ‘Small + ESS + elec. driven’, ‘Medium Supply 1-stage + elec. driven’, ‘Medium Supply 1-stage + AMS + elec. driven’, ‘Medium Supply 2-stage + elec. driven’, ‘Medium Supply 2-stage + AMS + elec. driven’, ‘Large Supply + elec. driven’, ‘Large Supply + AMS + elec. driven’, ‘Vacuum pump + elec. driven’; |
For PEV only ‘elec. driven’ technologies are allowed values.
| HVAC/Technology | P185 | string | [-] | Allowed values: ‘None’, ‘Default’ |
Table 3a Input parameters ‘Vehicle/Auxiliaries’ for heavy buses
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle) |
|---|---|---|---|---|---|---|
| EngineCoolingFan/Technology | P181 | string | [-] | Allowed values: ‘Crankshaft mounted - Electronically controlled visco clutch’, ‘Crankshaft mounted - Bimetallic controlled visco clutch’, ‘Crankshaft mounted - Discrete step clutch 2 stages’, ‘Crankshaft mounted - Discrete step clutch 3 stages’, ‘Crankshaft mounted - On/off clutch’, ‘Belt driven or driven via transmission - Electronically controlled visco clutch’, ‘Belt driven or driven via transmission - Bimetallic controlled visco clutch’, ‘Belt driven or driven via transmission - Discrete step clutch 2 stages’, ‘Belt driven or driven via transmission - Discrete step clutch 3 stages’, ‘Belt driven or driven via transmission - On/off clutch’, ‘Hydraulic driven - Variable displacement pump’, ‘Hydraulic driven - Constant displacement pump’, ‘Electrically driven - Electronically controlled’ | X | |
| SteeringPump/Technology | P182 | string | [-] | Allowed values: ‘Fixed displacement’, ‘Fixed displacement with elec. control’, ‘Dual displacement’, ‘Dual displacement with elec. control’, ‘Variable displacement mech. controlled’, ‘Variable displacement elec. controlled’, ‘Electric driven pump’, ‘Full electric steering gear’ |
For PEV or HEV with a powertrain configuration ‘S’ or ‘S-IEPC’ in accordance with point 10.1.1 only ‘Electric driven pump’ or ‘Full electric steering gear’ are allowed values
| Separate entry for each active steered wheel axle required. | X | |||
| ElectricSystem/AlternatorTechnology | P294 | string | [-] | Allowed values: ‘conventional’, ‘smart’, ‘no alternator’ |
Single entry per vehicle For pure ICE vehicles only ‘conventional’ or ‘smart’ are allowed values
| For HEV with a powertrain configuration ‘S’ or ‘S-IEPC’ in accordance with point 10.1.1 only ‘no alternator’ or ‘conventional’ are allowed values | X | ||||
|---|---|---|---|---|---|
| ElectricSystem/SmartAlternatorRatedCurrent | P295 | integer | [A] | Separate entry per smart alternator | X |
| ElectricSystem/SmartAlternatorRatedVoltage | P296 | Integer | [V] | Allowed values: ‘12’, ‘24’, ‘48’ | |
| Separate entry per smart alternator | X | ||||
| ElectricSystem/SmartAlternatorBatteryTechnology | P297 | string | [-] | Allowed values: ‘lead-acid battery – conventional’, ‘lead-acid battery – AGM’, ‘lead-acid battery – gel’, ‘li-ion battery - high power’, ‘li-ion battery - high energy’ | |
| Separate entry per battery charged by smart alternator system | X | ||||
| ElectricSystem/SmartAlternatorBatteryNominalVoltage | P298 | Integer | [V] | Allowed values: ‘12’, ‘24’, ‘48’ |
Where batteries are configured in series (e.g. two 12 V units for a 24 V system), the actual nominal voltage of the single battery units (12 V in this example) shall be provided.
| Separate entry per battery charged by smart alternator system | X | ||||
|---|---|---|---|---|---|
| ElectricSystem/SmartAlternatorBatteryRatedCapacity | P299 | Integer | [Ah] | Separate entry per battery charged by smart alternator system | X |
| ElectricSystem/SmartAlternatorCapacitorTechnology | P300 | string | [-] | Allowed values: ‘with DCDC converter’ | |
| Separate entry per capacitor charged by smart alternator system | X | ||||
| ElectricSystem/SmartAlternatorCapacitorRatedCapacitance | P301 | integer | [F] | Separate entry per capacitor charged by smart alternator system | X |
| ElectricSystem/SmartAlternatorCapacitorRatedVoltage | P302 | Integer | [V] | Separate entry per capacitor charged by smart alternator system | X |
| ElectricSystem/SupplyFromHEVPossible | P303 | boolean | [-] | X | |
| ElectricSystem/InteriorlightsLED | P304 | boolean | [-] | X | |
| ElectricSystem/DayrunninglightsLED | P305 | boolean | [-] | X | |
| ElectricSystem/PositionlightsLED | P306 | boolean | [-] | X | |
| ElectricSystem/BrakelightsLED | P307 | boolean | [-] | X | |
| ElectricSystem/HeadlightsLED | P308 | boolean | [-] | X | |
| PneumaticSystem/SizeOfAirSupply | P309 | string | [-] | Allowed values: ‘Small’, ‘Medium Supply 1-stage’, ‘Medium Supply 2-stage’, ‘Large Supply 1-stage’, ‘Large Supply 2-stage’, ‘not applicable’ |
For compressor drive electrically‘not applicable’ shall be provided.
| For PEV no input is required. | X | ||||
|---|---|---|---|---|---|
| PneumaticSystem/CompressorDrive | P310 | string | [-] | Allowed values: ‘mechanically’, ‘electrically’ | |
| For PEV, only ‘electrically’ is an allowed value. | X | ||||
| PneumaticSystem/Clutch | P311 | string | [-] | Allowed values: ‘none’, ‘visco’, ‘mechanically’ | |
| For PEV no input is required. | X | ||||
| PneumaticSystem/SmartRegenerationSystem | P312 | boolean | [-] | X | |
| PneumaticSystem/SmartCompressionSystem | P313 | boolean | [-] | For PEV or HEV with a powertrain configuration ‘S’ or ‘S-IEPC’ in accordance with point 10.1.1 no input is required. | X |
| PneumaticSystem/Ratio Compressor ToEngine | P314 | double, 3 | [-] | For compressor drive electrically‘0.000’ shall be provided. | |
| For PEV no input is required. | X | ||||
| PneumaticSystem/Air suspension control | P315 | string | [-] | Allowed values: ‘mechanically’, ‘electronically’ | X |
| PneumaticSystem/SCRReagentDosing | P316 | boolean | [-] | X | |
| HVAC/SystemConfiguration | P317 | int | [-] | Allowed values: ‘0’ to ‘10’ | |
| In the case of an incomplete HVAC system, ‘0’ shall be provided. ‘0’ is not applicable for complete or completed vehicles. | X | ||||
| HVAC/ HeatPumpTypeDriverCompartmentCooling | P318 | string | [-] | Allowed values: ‘none’, ‘not applicable’, ‘R-744’, ‘non R-744 2-stage’, ‘non R-744 3-stage’, ‘non R-744 4-stage’, ‘non R-744 continuous’ | |
| ‘not applicable’ shall be declared for HVAC system configurations 6 and 10 due to supply from passenger heat pump | X | ||||
| HVAC/ HeatPumpTypeDriverCompartmentHeating | P319 | string | [-] | Allowed values: ‘none’, ‘not applicable’, ‘R-744’, ‘non R-744 2-stage’, ‘non R-744 3-stage’, ‘non R-744 4-stage’, ‘non R-744 continuous’ | |
| ‘not applicable’ shall be declared for HVAC system configurations 6 and 10 due to supply from passenger heat pump | X | ||||
| HVAC/ HeatPumpTypePassengerCompartmentCooling | P320 | string | [-] | Allowed values: ‘none’, ‘R-744’, ‘non R-744 2-stage’, ‘non R-744 3-stage’, non R-744 4-stage’, ‘non R-744 continuous’ | |
| In the case of multiple heat pumps with different technologies for cooling the passenger compartment, the dominant technology shall be declared (e.g. according to available power or preferred usage in operation). | X | ||||
| HVAC/ HeatPumpTypePassengerCompartmentHeating | P321 | string | [-] | Allowed values: ‘none’, ‘R-744’, ‘non R-744 2-stage’, ‘non R-744 3-stage’, non R-744 4-stage’, ‘non R-744 continuous’ | |
| In the case of multiple heat pumps with different technologies for heating the passenger compartment, the dominant technology shall be declared (e.g. according to available power or preferred usage in operation). | X | ||||
| HVAC/AuxiliaryHeaterPower | P322 | integer | [W] | Enter ‘0’ if no auxiliary heater is installed. | X |
| HVAC/Double glazing | P323 | boolean | [-] | X | |
| HVAC/AdjustableCoolantThermostat | P324 | boolean | [-] | X | |
| HVAC/AdjustableAuxiliaryHeater | P325 | boolean | [-] | X | |
| HVAC/EngineWasteGasHeatExchanger | P326 | boolean | [-] | For PEV no input is required. | X |
| HVAC/SeparateAirDistributionDucts | P327 | boolean | [-] | X | |
| HVAC/WaterElectricHeater | P328 | boolean | [-] | Input to be provided only for HEV and PEV | X |
| HVAC/AirElectricHeater | P329 | boolean | [-] | Input to be provided only for HEV and PEV | X |
| HVAC/OtherHeating Technology | P330 | boolean | [-] | Input to be provided only for HEV and PEV | X |
Table 4 Input parameters ‘Vehicle/EngineTorqueLimits’ per gear (optional)
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| Gear | P196 | integer | [-] | only gear numbers need to be specified where vehicle related engine torque limits according to point 6 are applicable | X | X | X | |
| MaxTorque | P197 | integer | [Nm] | X | X | X |
Table 5 Input parameters for vehicles exempted according to Article 9
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete and completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| Manufacturer | P235 | token | [-] | X | X | X | X | |
| ManufacturerAddress | P252 | token | [-] | X | X | X | X | |
| Model_CommercialName | P236 | token | [-] | X | X | X | X | |
| VIN | P238 | token | [-] | X | X | X | X | |
| Date | P239 | date Time | [-] | Date and time when input information and input data is created | X | X | X | X |
| LegislativeCategory | P251 | string | [-] | Allowed values: ‘N2’, ‘N3’, ‘M3’ | X | X | X | X |
| ChassisConfiguration | P036 | string | [-] | Allowed values: ‘Rigid Lorry’, ‘Tractor’, ‘Van’, ‘Bus’ | X | X | X | |
| AxleConfiguration | P037 | string | [-] | Allowed values: ‘4 × 2’, ‘4 × 2F’, ‘6 × 2’, ‘6 × 4’, ‘8 × 2’, ‘8 × 4’ where ‘4 × 2F’ refers to 4 × 2 vehicles with a driven front axle | X | X | X | |
| Articulated | P281 | boolean | in accordance with the definition set out in Annex I to this Regulation. | X | ||||
| CorrectedActualMass | P038 | int | [kg] | In accordance with ‘Corrected actual mass of the vehicle’ as specified in section 2 point (4) | X | X | X | |
| TechnicalPermissibleMaximumLadenMass | P041 | int | [kg] | In accordance with Article 2, point (7), of Regulation (EU) No 1230/2012 | X | X | X | X |
| ZeroEmissionVehicle | P269 | boolean | [-] | As defined in Article 3, point (15) | X | X | X | |
| Sleepercab | P276 | boolean | [-] | X | ||||
| ClassBus | P282 | string | [-] | Allowed values: ‘I’, ‘I+II’, ‘A’, ‘II’, ‘II+III’, ‘III’, ‘B’ in accordance with paragraph 2 of UN Regulation No. 107 | X | |||
| NumberPassengersSeatsLowerDeck | P283 | int | [-] | Number of passenger seats - excluding driver and crew seats. | ||||
| In the case of a double deck vehicle, this parameter shall be used to declare the passenger seats from the lower deck. In the case of a single deck vehicle, this parameter shall be used to declare the number of total passenger seats. | X | |||||||
| NumberPassengersStandingLowerDeck | P354 | int | [-] | Number of registered standing passengers | ||||
| In the case of a double deck vehicle, this parameter shall be used to declare the registered standing passengers from the lower deck. In the case of a single deck vehicle, this parameter shall be used to declare the total number of registered standing passengers. | X | |||||||
| NumberPassengersSeatsUpperDeck | P284 | int | [-] | Number of passenger seats - excluding driver and crew seats of the upper deck in a double deck vehicle. | ||||
| For single deck vehicles ‘0’ shall be provided as input. | X | |||||||
| NumberPassengersStandingUpperDeck | P355 | int | [-] | Number of registered standing passengers of the upper deck in a double deck vehicle. | ||||
| For single deck vehicles ‘0’ shall be provided as input. | X | |||||||
| BodyworkCode | P285 | int | [-] | Allowed values: ‘CA’, ‘CB’, ‘CC’, ‘CD’, ‘CE’, ‘CF’, ‘CG’, ‘CH’, ‘CI’, ‘CJ’ in accordance with point 3 of part C of Annex I to Regulation (EU) 2018/585 | X | |||
| LowEntry | P286 | boolean | [-] | ‘low entry’ in accordance with point 1.2.2.3 of Annex I | X | |||
| HeightIntegratedBody | P287 | int | [mm] | in accordance with point 2(5) | X | |||
| SumNetPower | P331 | int | [W] | Maximum possible sum of positive propulsion power of all energy converters, which are linked to the vehicle drivetrain or the wheels | X | X | X | |
| Technology | P332 | string | [-] | In accordance with Table 1 of Appendix 1. | ||||
| Allowed values: ‘Dual-fuel vehicle Article 9 exempted’, ‘In-motion charging Article 9 exempted’, ‘Multiple powertrains Article 9 exempted’, ‘FCV Article 9 exempted’, ‘H2 ICE Article 9 exempted’, ‘HEV Article 9 exempted’, ‘PEV Article 9 exempted’, ‘HV Article 9 exempted’ | X | X | X |
Table 6 Input parameters ‘Advanced driver assistance systems’
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete and completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| EngineStopStart | P271 | boolean | [-] | In accordance with point 8.1.1 | ||||
| Input only to be provided for pure ICE vehicles and HEV. | X | X | X | X | ||||
| EcoRollWithoutEngineStop | P272 | boolean | [-] | In accordance with point 8.1.2 | ||||
| Input only to be provided for pure ICE vehicles. | X | X | X | X | ||||
| EcoRollWithEngineStop | P273 | boolean | [-] | In accordance with point 8.1.3 | ||||
| Input only to be provided for pure ICE vehicles. | X | X | X | X | ||||
| PredictiveCruiseControl | P274 | string | [-] | In accordance with point 8.1.4, allowed values: ‘1,2’, ‘1,2,3’ | X | X | X | X |
| APTEcoRollReleaseLockupClutch | P333 | boolean | [-] | Only relevant in the case of APT-S and APT-P transmissions in combination with any Eco-roll function. Set to ‘true’ if functionality (2) as defined in point 8.1.2 is the predominant Eco-roll mode. | ||||
| Input only to be provided for pure ICE vehicles. | X | X | X | X |
Table 7 General input parameters for HEV and PEV
| Parameter name | Parameter ID | Type | Unit | Description/Reference | Heavy lorries | Medium lorries | Heavy buses (primary vehicle) | Heavy buses (complete or completed vehicle) |
|---|---|---|---|---|---|---|---|---|
| ArchitectureID | P400 | string | [-] | In accordance with point 10.1.3, the following values are allowed inputs: | ||||
| ‘E2’, ‘E3’, ‘E4’, ‘E-IEPC’, ‘P1’, ‘P2’, ‘P2.5’, ‘P3’, ‘P4’, ‘S2’, ‘S3’, ‘S4’, ‘S-IEPC’ | X | X | X | |||||
| OvcHev | P401 | boolean | [-] | In accordance with point 2(31) | X | X | X | |
| MaxChargingPower | P402 | Integer | [W] | The maximum charging power allowed by the vehicle for off-vehicle charging shall be declared as input to the simulation tool. | ||||
| Only relevant where parameter ‘OvcHev’ is set to ‘true’. | X | X | X |
Table 8 Input parameters per electric machine position (Only applicable if the component is present in the vehicle)
| Parameter name | Parameter ID | Type | Unit | Description/Reference |
| PowertrainPosition | P403 | string | [-] | Position of the EM in the vehicle’s powertrain according to points 10.1.2 and 10.1.3. |
Allowed values: ‘1’, ‘2’, ‘2.5’, ‘3’, ‘4’, ‘GEN’. Only one EM position per powertrain allowed, except for architecture ‘S’. Architecture ‘S’ requires EM position ‘GEN’ and additionally one other EM position being ‘2’, ‘3’ or ‘4’. Position ‘1’ is not allowed for architectures ‘S’ and ‘E’ Position ‘GEN’ is only allowed for architecture ‘S’
| Count | P404 | integer | [-] | Number of identical electric machines at the specified EM position. |
In the case of parameter ‘PowertrainPosition’ being ‘4’, the count shall be multiples of 2 (e.g. 2, 4, 6).
| CertificationNumberEM | P405 | token | [-] | |
| CertificationNumberADC | P406 | token | [-] | Optional input in the case of additional single-step gear ratio (ADC) between EM shaft and connection point to vehicle’s powertrain according to point 10.1.2 |
Not allowed where parameter ‘IHPCType’ is set to ‘IHPC Type 1’.
| P2.5GearRatios | P407 | double, 3 | [-] | Only applicable in the case that the parameter ‘PowertrainPosition’ is set to ‘P2.5’ |
Declared for each forward gear of the transmission. Declared value for gear ratio defined by either ‘nGBX_in / nEM’ in the case of EM without additional ADC or ‘nGBX_in / nADC’ in the case of EM with additional ADC. nGBX_in = rotational speed at transmission input shaft nEM = rotational speed at EM output shaft nADC = rotational speed at ADC output shaft Table 9 Torque limitations per electric machine position (optional) Declaration of separate dataset for each voltage level measured under ‘CertificationNumberEM’. Declaration not allowed where parameter ‘IHPCType’ is set to ‘IHPC Type 1’.
| Parameter name | Parameter ID | Type | Unit | Description/Reference |
|---|---|---|---|---|
| OutputShaftSpeed | P408 | double, 2 | [1/min] | Exact same entries for rotational speed to be declared as under ‘CertificationNumberEM’ for parameter number ‘P468’ of Appendix 15 of Annex Xb. |
| MaxTorque | P409 | double, 2 | [Nm] | Maximum torque of the EM (referring to the output shaft) as function of rotational speed points declared under parameter number ‘P469’ of Appendix 15 of Annex Xb. |
Each value of maximum torque declared shall either be lower than 0,9 times the original value at the respective rotational speed or match exactly the original value at the respective rotational speed. The values of maximum torque declared shall not be lower than zero. Where the parameter ‘Count’ (P404) is larger than one, the maximum torque shall be declared for a single EM (as present in the component test for the EM under ‘CertificationNumberEM’).
| MinTorque | P410 | double, 2 | [Nm] | Minimum torque of the EM (referring to the output shaft) as function of rotational speed points declared under parameter number ‘P470’ of Appendix 15 of Annex Xb. |
Each value of minimum torque declared shall either be higher than 0.9 times the original value at the respective rotational speed or match exactly the original value at the respective rotational speed. The values of minimum torque declared shall not be higher than zero. Where the parameter ‘Count’ (P404) is larger than one, the minimum torque shall be declared for a single EM (as present in the component test for the EM under ‘CertificationNumberEM’). Table 10 Input parameters per REESS (Only applicable if the component is present in the vehicle)
| Parameter name | Parameter ID | Type | Unit | Description/Reference |
| StringID | P411 | integer | [-] | The arrangement of representative battery sub-systems in accordance with Annex Xb on vehicle level shall be declared by allocation of each battery sub-system to a specific string defined by this parameter. All specific strings are connected in parallel, all battery sub-system located in one specific parallel string are connected in series. |
Allowed values: ‘1’, ‘2’, ‘3’, …
| CertificationNumberREESS | P412 | token | [-] | |
| SOCmin | P413 | integer | [%] | Optional input. |
Only relevant in the case of REESS type ‘battery’. Parameter only effective in simulation tool where input is higher than generic value as documented in the user manual.
| SOCmax | P414 | integer | [%] | Optional input |
Only relevant in the case of REESS type ‘battery’. Parameter only effective in simulation tool where input is lower than generic value as documented in the user manual. Table 11 Boosting limitations for parallel HEV (optional) Only allowed where powertrain configuration in accordance with point 10.1.1 is ‘P’ or ‘IHPC Type 1’.
| Parameter name | Parameter ID | Type | Unit | Description/Reference |
|---|---|---|---|---|
| RotationalSpeed | P415 | double, 2 | [1/min] | Referring to transmission input shaft speed |
| BoostingTorque | P416 | double, 2 | [Nm] | In accordance with point 10.2 |
4. Vehicle mass for medium rigid lorries and tractors, heavy rigid lorries and tractors
Front underrun protection in accordance with Regulation (EU) 2019/2144 (**) of the European Parliament and of the Council
Changed in this versionRear underrun protection in accordance with Regulation (EU) 2019/2144
Changed in this versionLateral protection in accordance with Regulation (EU) 2019/2144
Changed in this versionFifth wheel in accordance with Regulation (EU) 2019/2144 4.3 The mass of the construction elements referred to in point 4.2 shall be the following: For vehicles of groups 1s, 1, 2 and 3 as set out in Annex I, Table 1, and for vehicle groups 51 and 53 as set out in Annex I, Table 2.
| Front underride protection | 45 kg |
|---|---|
| Rear underride protection | 40 kg |
| Lateral protection | 8,5 kg/m × wheel base [m] – 2,5 kg |
For vehicles of groups 4, 5, 9 to 12 and 16 as set out in Annex I, Table 1.
| Front under-ride protection | 50 kg |
|---|---|
| Rear under-ride protection | 45 kg |
| Lateral protection | 14 kg/m × wheel base [m] – 17 kg |
| Fifth wheel | 210 kg |
5. Hydraulically and mechanically driven axles
a hydraulically driven axles, the axle shall be treated as a non-drivable one and the manufacturer shall not take it into consideration for establishing an axle configuration of a vehicle;
Changed in this versiona mechanically driven axles, the axle shall be treated as a drivable one and the manufacturer shall take it into consideration for establishing an axle configuration of a vehicle;
Changed in this version6. Gear dependent engine torque limits and gear disabling
6.1. Gear dependent engine torque limits
6.2 Gear disabling
6.3 Verification requirements
7. Vehicle specific engine idling speed
The engine idling speed has to be declared for each individual vehicle with an ICE. This declared vehicle engine idling shall be equal or higher than specified in the engine input data approval.
Changed in this version8. Advanced driver assistance systems
Crest coasting Approaching a crest the vehicle velocity is reduced before the point where the vehicle starts accelerating by gravity alone compared to the set speed of the cruise control so that the braking during the following downhill phase can be reduced.
Changed in this versionAcceleration without engine power During downhill driving with a low vehicle velocity and a high negative slope the vehicle acceleration is performed without any engine power usage so that the downhill braking can be reduced.
Changed in this versionDip coasting During downhill driving when the vehicle is braking at the overspeed velocity, PCC increases the overspeed for a short period of time to end the downhill event with a higher vehicle velocity. Overspeed is a higher vehicle speed than the set speed of the cruise control system. A PCC system can be declared as input to the simulation tool if either the functionalities set out in points (1) and (2) or points (1), (2) and (3) are covered. 8.2 The eleven combinations of the advanced driver assistance systems as set out in Table 12 are input parameters into the simulation tool. Combinations 2 to 11 shall not be declared for SMT transmissions. Combinations No 3, 6, 9 and 11 shall not be declared in the case of APT transmissions. Table 12 Combinations of advanced driver assistance systems as input parameters into the simulation tool
| Combination no | Engine stop-start during vehicle stops | Eco-roll without engine stop-start | Eco-roll with engine stop-start | Predictive cruise control |
|---|---|---|---|---|
| 1 | yes | no | no | no |
| 2 | no | yes | no | no |
| 3 | no | no | yes | no |
| 4 | no | no | no | yes |
| 5 | yes | yes | no | no |
| 6 | yes | no | yes | no |
| 7 | yes | no | no | yes |
| 8 | no | yes | no | yes |
| 9 | no | no | yes | yes |
| 10 | yes | yes | no | yes |
| 11 | yes | no | yes | yes |
8.3 Any advanced driver assistance system declared in the input into the simulation tool shall by default be set to fuel economy mode after each key-off/key-on cycle. 8.4 If an advanced driver assistance system is declared in the input into the simulation tool, it shall be possible to verify the presence of such a system based on real world driving and the system definitions as set out in point 8.1. If a certain combination of systems is declared, also the interaction of functionalities (e.g. predictive cruise control plus eco-roll with engine stop-start) shall be demonstrated. In the verification procedure it shall be taken into consideration, that the systems need certain boundary conditions to be ‘active’ (e.g. engine at operation temperature for engine stop-start, certain vehicle speed ranges for PCC, certain ratios of road gradients with vehicle mass for eco-roll). The vehicle manufacturer needs to submit a functional description of boundary conditions when the systems are ‘inactive’ or their efficiency is reduced. The approval authority may request the technical justifications of these boundary conditions from the applicant for approval and assess them for compliance.
Changed in this version9. Cargo volume
For vehicles of chassis configuration ‘van’ the cargo volume shall be calculated by the following equation: where the dimensions shall be determined in accordance with Table 13 and Figure 3. Table 13 Definitions related to cargo volume for medium lorries of type van
| Formula symbol | Dimension | Definition |
| LC,floor | Cargo length at floor | — longitudinal distance from the most rearward point of the last seating row or the partition wall to the foremost point of the closed rear compartment projected to the zero Y-plane |
— measured at the height of the cargo floor surface
LC | Cargo length | — longitudinal distance from the X-plane tangent to the most rearward point on the seatback including head restraints of the last seating row or the partition wall to the foremost X-plane tangent to the closed rear compartment i.e. the tailgate or rear doors or any other limiting surface
— measured at the height of the most rearward point of the last seating row or the partition wall
WC,max | Maximum cargo width | — maximum lateral distance of the cargo compartment
— measured between the cargo floor and 70 mm above the floor
— measurement excludes the transitional arc, local protrusions, depressions or pockets if present
WC,wheelhouse | Cargo width at wheelhouse | — minimum lateral distance between the limiting interferences (pass-through) of the wheelhouses
— measured between the cargo floor and 70 mm above the floor
— measurement excludes the transitional arc, local protrusions, depressions or pockets if present
HC,max | Maximum cargo height | — Maximum vertical distance from the cargo floor to the headlining or other limiting surface
— Measured behind the last seating row or partition wall at the vehicle centreline
HC,rearwheel | Cargo height at rear wheel | — vertical distance from the top of the cargo floor to the headlining or the limiting surface
— measured at the rear wheel X coordinate at the vehicle centreline
Changed in this versionFigure 3
Definition of cargo volume for medium lorries
10. HEV and PEV
10.1 Definition of vehicle’s powertrain architecture
10.1.1 Definition of powertrain configuration
‘P’ in the case of a parallel HEV
Changed in this version‘S’ in the case of a serial HEV
Changed in this version‘S-IEPC’ in the case an IEPC component is present in the vehicle
Changed in this version‘IHPC Type 1’ in the case the parameter ‘IHPCType’ of the electric machine component is set to ‘IHPC Type 1’ In the case of a PEV:
Changed in this version‘E’ in the case an EM component is present in the vehicle
Changed in this version‘E-IEPC’ in the case an IEPC component is present in the vehicle
Changed in this version10.1.2 Definition of positions of EMs in the vehicle’s powertrain
10.1.3 Definition of powertrain architecture ID
The powertrain architecture ID ‘P2’ shall be declared in accordance with Table 7 and the powertrain component data as indicated in Table 15 for ‘P2’ shall be the input to the simulation tool with separate component data for the EM and the transmission determined in accordance with point 4.4.3 of Annex Xb.
Changed in this versionThe component data for the EM in accordance with subpoint (a) shall be provided to the simulation tool with the parameter ‘PowertrainPosition’ in accordance with Table 8 set to ‘2’. Table 15 Valid inputs of powertrain architecture into the simulation tool
| Powertrain type | Powertrain configuration | Architecture ID for VECTO input | Powertrain component present in vehicle | Comments | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| ICE | EM position GEN | EM position 1 | EM position 2 | transmission | EM position 3 | axle | EM position 4 | |||
| PEV | E | E2 | no | no | no | yes | yes | no | yes | no |
| E3 | no | no | no | no | no | yes | yes | no | ||
| E4 | no | no | no | no | no | no | no | yes | ||
| IEPC | E-IEPC | no | no | no | no | no | no | (1) | no | |
| HEV | P | P1 | yes | no | yes | no | yes | no | yes | no |
| P2 | yes | no | no | yes | yes | no | yes | no | (2) | |
| P2.5 | yes | no | no | yes | yes | no | yes | no | (3) | |
| P3 | yes | no | no | no | yes | yes | yes | no | (4) | |
| P4 | yes | no | no | no | yes | no | yes | yes | ||
| S | S2 | yes | yes | no | yes | yes | no | yes | no | |
| S3 | yes | yes | no | no | no | yes | yes | no | ||
| S4 | yes | yes | no | no | no | no | no | yes | ||
| S-IEPC | yes | yes | no | no | no | no | (1) | no |
(1) ‘Yes’ (i.e. axle component present) only in the case that both parameters ‘DifferentialIncluded’ and ‘DesignTypeWheelMotor’ are set to ‘false’
(2) Not applicable for transmission types APT-S and APT-P
(3) Where the EM is connected to a specific shaft inside the transmission (e.g. layshaft) in accordance with the definition set out in Table 8
(4) Not applicable for front wheel driven vehicles
Changed in this version10.2 Definition of boosting limitation for parallel HEV
10.3 Engine stop-start functionality for HEVs
11. Transfer of results of the simulation tool to other vehicles
Results of the simulation tool may be transferred to other vehicles as provided for in Article 9(6), provided that all of the following conditions are met:
Changed in this versioninput data and input information is completely identical with exception of VIN (P238) and Date element (P239). In the case of simulations for primary heavy buses, additional input data and input information relevant for the interim vehicle and available already at the initial stage may differ, but special measures have to be taken in this case;
Changed in this versionthe version of the simulation tool is identical.
Changed in this versionFor the transfer of results the following result files shall be considered:
Changed in this versionmedium and heavy lorries: manufacturer’s records file and customer information file
Changed in this versionprimary heavy buses: manufacturer’s records file and vehicle information file
Changed in this versioncomplete or completed heavy buses: manufacturer’s records file, customer information file and vehicle information file
Changed in this versionTo carry out the transfer of results the files as mentioned in 10.2. shall be modified by replacing the data elements as set out in the subpoints with updated information. Modifications are allowed only for data elements related to the current stage of completion.
Changed in this version11.3.1 Manufacturer’s records file
VIN (Annex IV, Part I, point 1.1.3)
Changed in this versionDate when the output file was created (Annex IV, Part I, point 3.2)
Changed in this version11.3.2 Customer information file
VIN (Annex IV, Part II, point 1.1.1)
Changed in this versionDate when the output file was created (Annex IV, Part II, point 3.2)
Changed in this version11.3.3 Vehicle information file
In the case of a primary heavy bus:
Changed in this versionVIN (Annex IV, Part III, point 1.1)
Changed in this versionDate when the output file was created (Annex IV, Part III, point 1.3.2)
Changed in this versionWhere a manufacturer of a primary heavy bus provides data going beyond the primary vehicle requirements and which differs between original vehicle and transferred vehicle, the related data elements in the vehicle information file shall be updated accordingly.
Changed in this versionIn the case of a complete or completed heavy bus:
Changed in this versionVIN (Annex IV, Part III, point 2.1)
Changed in this versionDate when the output file was created (Annex IV, Part III, point 2.2.2)
11.3.4 | After the modifications as described above the signature elements as set out below shall be updated.
11.3.4.1. Lorries:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.6. and 3.7
(b)
Customer information file: Annex IV, Part II, points 3.3 and 3.4
11.3.4.2. Primary heavy buses:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.3 and 3.4
(b)
Vehicle information file: Annex IV, Part III, points 1.4.1 and 1.4.2
11.3.4.3. Primary heavy buses where additionally input data for the interim vehicle has been provided:
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.3 and 3.4
(b)
Vehicle information file: Annex IV, Part III, points 1.4.1, 1.4.2 and 2.3.1
11.3.4.4. Complete or completed heavy buses
(a)
Manufacturer’s records file: Annex IV, Part I, points 3.6 and 3.7
(b)
Vehicle information file: Annex IV, Part III, point 2.3.1
Changed in this versionWhere CO2 emissions and fuel consumption cannot be determined for the original vehicle due to a malfunction of the simulation tool, the same measures shall apply to the vehicles with transferred results.
Changed in this versionIf the approach to transfer results to other vehicles as laid down in this paragraph is applied by a manufacturer, the related process shall be demonstrated to the approval authority as part of granting the process licence.
Changed in this versionAppendix 1
Vehicle technologies for which the obligations laid down in Article 9(1), first subparagraph, do not apply, as provided in that subparagraph
ANNEX IV
MODEL OF THE OUTPUT FILES OF THE SIMULATION TOOL
1. Introduction
2. Definitions
3. Model of the output files
PART I
Vehicle, component, separate technical unit and systems data
Changed in this versionVehicle data
Changed in this versionName and address of manufacturer (s) …
Changed in this versionVehicle model / Commercial Name …
Changed in this versionVehicle identification number (VIN) …
Changed in this versionVehicle category (N2, N3, M3) …
Changed in this versionAxle configuration …
Changed in this versionTechnically Permissible Maximum Laden Mass (t) …
Changed in this versionVehicle group in accordance with Annex I … 1.1.7a. Vehicle (sub-)group for CO2 standards …
Changed in this versionCorrected actual mass (kg) …
Changed in this versionVocational vehicle (yes/no) …
Changed in this versionZero emission heavy-duty vehicle (yes/no) …
Changed in this versionHybrid electric heavy-duty vehicle (yes/no) …
Changed in this versionDual-fuel vehicle (yes/no) …
Changed in this versionSleeper cab (yes/no) …
Changed in this versionHEV architecture (e.g. P1, P2) …
Changed in this versionPEV architecture (e.g. E2, E3) …
Changed in this versionOff-vehicle charging capability (yes/no) …
Changed in this version–
Changed in this versionOff-vehicle charging maximum power (kW) …
Changed in this versionVehicle technology exempted according to Article 9 …
Changed in this versionClass of bus (e.g. I, I+II etc.) …
Changed in this versionNumber passengers upper deck …
Changed in this versionNumber passengers lower deck …
Changed in this versionCode for bodywork (e.g. CA, CB) …
Changed in this versionLow Entry (yes/no) …
Changed in this versionHeight integrated body (mm) …
Changed in this versionVehicle length (mm) …
Changed in this versionVehicle width (mm) …
Changed in this versionDoor drive technology (pneumatic, electric, mixed) …
Changed in this versionTank system in the case of natural gas (compressed, liquified) …
Changed in this versionSum net power (only for Article 9 exempted) (kW) …
Changed in this versionMain engine specifications
Changed in this versionEngine model …
Changed in this versionEngine certification number …
Changed in this versionEngine rated power (kW) …
Changed in this versionEngine idling speed (1/min) …
Changed in this versionEngine rated speed (1/min) …
Changed in this versionEngine capacity (ltr) …
Changed in this versionFuel type (Diesel CI/CNG PI/LNG PI) …
Changed in this versionHash of the engine input data and input information …
Changed in this versionWaste heat recovery system (yes/no) …
Changed in this versionWaste heat recovery type(s) (mechanical/electrical) …
Changed in this versionMain transmission specifications
Changed in this versionTransmission model …
Changed in this versionTransmission certification number …
Changed in this versionMain option used for generation of loss maps (Option1/Option2/Option3/Standard values) …
Changed in this versionTransmission type (SMT, AMT, APT-S, APT-P, APT-N) …
Changed in this versionNo. of gears …
Changed in this versionTransmission ratio final gear …
Changed in this versionRetarder type …
Changed in this versionPower take off (yes/no) …
Changed in this versionHash of the transmission input data and input information …
Changed in this versionRetarder specifications
Changed in this versionRetarder model …
Changed in this versionRetarder certification number …
Changed in this versionCertification option used for generation of a loss map (standard values/measurement) …
Changed in this versionHash of the other torque transferring components input data and input information …
Changed in this versionTorque converter specification
Changed in this versionTorque converter model …
Changed in this versionTorque converter certification number …
Changed in this versionCertification option used for generation of a loss map (standard values/measurement) …
Changed in this versionHash of the torque converter input data and input information …
Changed in this versionAngle drive specifications
Changed in this versionAngle drive model …
Changed in this versionAngle drive certification number …
Changed in this versionCertification option used for generation of a loss map (standard values/measurement) …
Changed in this versionAngle drive ratio …
Changed in this versionHash of the additional drivetrain components input data and input information …
Changed in this versionAxle specifications
Changed in this versionAxle model …
Changed in this versionAxle certification number …
Changed in this versionCertification option used for generation of a loss map (standard values/measurement) …
Changed in this versionAxle type (e.g. single reduction axle) …
Changed in this versionAxle ratio …
Changed in this versionHash of the axle input data and input information …
Changed in this versionAerodynamics
Changed in this versionModel …
Changed in this versionCertification option used for generation of CdxA (standard values/measurement) …
Changed in this versionCdxA Certification number (if applicable) …
Changed in this versionCdxA value …
Changed in this versionHash of the air drag input data and input information …
Changed in this versionMain tyre specifications
Changed in this versionTyre dimension axle 1 …
Changed in this versionTyre certification number axle 1 …
Changed in this versionSpecific RRC of all tyres on axle 1 … 1.9.3a. Hash of the tyre input data and input information axle 1 …
Changed in this versionTyre dimension axle 2 …
Changed in this versionTwin axle (yes/no) axle 2 …
Changed in this versionTyre certification number axle 2 …
Changed in this versionSpecific RRC of all tyres on axle 2 … 1.9.7a. Hash of the tyre input data and input information axle 2 …
Changed in this versionTyre dimension axle 3 …
Changed in this versionTwin axle (yes/no) axle 3 …
Changed in this versionTyre certification number axle 3 …
Changed in this versionSpecific RRC of all tyres on axle 3 … 1.9.11a. Hash of the tyre input data and input information axle 3 …
Changed in this versionTyre dimension axle 4 …
Changed in this versionTwin axle (yes/no) axle 4 …
Changed in this versionTyre certification number axle 4 …
Changed in this versionSpecific RRC of all tyres on axle 4 …
Changed in this versionHash of the tyre input data and input information axle 4 …
Changed in this versionAuxiliary specifications
Changed in this versionEngine cooling fan technology …
Changed in this versionSteering pump technology …
Changed in this versionElectric system
Changed in this versionAlternator technology (conventional, smart, no alternator) …
Changed in this versionMax alternator power (smart alternator) (kW) …
Changed in this versionElectric storage capacity (smart alternator) (kWh) …
Changed in this versionDay running lights LED (yes/no) …
Changed in this versionHead lights LED (yes/no) …
Changed in this versionPosition lights LED (yes/no) …
Changed in this versionBrake lights LED (yes/no) …
Changed in this versionInterior lights LED (yes/no) …
Changed in this versionPneumatic system
Changed in this versionTechnology …
Changed in this versionCompressor ratio …
Changed in this versionSmart compression system …
Changed in this versionSmart regeneration system …
Changed in this versionAir suspension control …
Changed in this versionReagent dosing (exhaust after-treatment) …
Changed in this versionHVAC system
Changed in this versionSystem configuration number …
Changed in this versionHeat pump type cooling driver compartment …
Changed in this versionHeat pump mode heating driver compartment …
Changed in this versionHeat pump type cooling passenger compartment …
Changed in this versionHeat pump mode heating passenger compartment …
Changed in this versionAuxiliary heater power (kW) …
Changed in this versionDouble glasing (yes/no) …
Changed in this versionAdjustable coolant thermostat (yes/no) …
Changed in this versionAdjustable auxiliary heater …
Changed in this versionEngine waste gas heat exchanger (yes/no) …
Changed in this versionSeparate air distribution ducts (yes/no) …
Changed in this versionWater electric heater
Changed in this versionAir electric heater
Changed in this versionOther heating technology
Changed in this versionEngine torque limitations
Changed in this versionEngine torque limit at gear 1 (% of max engine torque) …
Changed in this versionEngine torque limit at gear 2 (% of max engine torque) …
Changed in this versionEngine torque limit at gear 3 (% of max engine torque) …
Changed in this versionEngine torque limit at gear … (% of max engine torque)
Changed in this versionAdvanced driver assistance systems (ADAS)
Changed in this versionEngine stop-start during vehicle stops (yes/no) …
Changed in this versionEco-roll without engine stop-start (yes/no) …
Changed in this versionEco-roll with engine stop-start (yes/no) …
Changed in this versionPredictive cruise control (yes/no) …
Changed in this versionElectric machine system(s) specifications 1.13.1 Model …
Changed in this versionCertification number 1.13.3 Type (PSM, ESM, IM, SRM) …
Changed in this versionPosition (GEN 1, 2, 3, 4) …
Changed in this version–
Changed in this versionCount at position …
Changed in this versionRated power (kW) …
Changed in this versionMaximum continuous power (kW) …
Changed in this versionCertification option for generation of electric power consumption map …
Changed in this versionHash of the input data and input information …
Changed in this versionADC model …
Changed in this versionADC certification number …
Changed in this versionCertification option used for generation of an ADC loss map (standard values/measurement) …
Changed in this versionADC ratio …
Changed in this versionHash of the additional driveline components’ input data and input information …
Changed in this versionIntegrated electric powertrain system (IEPC) specifications 1.14.1 Model …
Changed in this versionCertification number …
Changed in this versionRated power (kW) …
Changed in this versionMaximum continuous power (kW) …
Changed in this versionNumber of gears …
Changed in this versionLowest total transmission ratio (highest gear times axle ratio if applicable) …
Changed in this versionDifferential included (yes/no) …
Changed in this versionCertification option for generation of electric power consumption map …
Changed in this versionHash of the input data and input information …
Changed in this versionRechargeable Energy Storage Systems specifications 1.15.1 Model …
Changed in this versionCertification number …
Changed in this versionNominal voltage (V) …
Changed in this versionTotal storage capacity (kWh) …
Changed in this versionTotal usable capacity in simulation (kWh) …
Changed in this versionCertification option for electric system losses …
Changed in this versionHash of the input data and input information …
Changed in this versionStringID (-) …
Changed in this versionMission profile and loading dependent values
Changed in this versionSimulation parameters (for each mission profile and loading combination, for OVC-HEVs additionally for charge depleting, charge sustaining mode and weighted)
Changed in this versionMission profile …
Changed in this versionLoad (as defined in the simulation tool) (kg) … 2.1.2a. Passenger count …
Changed in this versionTotal vehicle mass in simulation (kg) …
Changed in this versionOVC mode (charge depleting, charge sustaining, weighted) …
Changed in this versionVehicle driving performance and information for simulation quality check
Changed in this versionAverage speed (km/h) …
Changed in this versionMinimum instantaneous speed (km/h) …
Changed in this versionMaximum instantaneous speed (km/h) …
Changed in this versionMaximum deceleration (m/s2) …
Changed in this versionMaximum acceleration (m/s2) …
Changed in this versionFull load percentage of driving time …
Changed in this versionTotal number of gear shifts …
Changed in this versionTotal driven distance (km) …
Changed in this versionFuel and energy consumption (per fuel type and electric energy) and CO2 results (total)
Changed in this versionFuel consumption (g/km) …
Changed in this versionFuel consumption (g/t-km) …
Changed in this versionFuel consumption (g/p-km) …
Changed in this versionFuel consumption (g/m3-km) …
Changed in this versionFuel consumption (l/100km) …
Changed in this versionFuel consumption (l/t-km) …
Changed in this versionFuel consumption (l/p-km) …
Changed in this versionFuel consumption (l/m3-km) …
Changed in this versionEnergy consumption (MJ/km, kWh/km) …
Changed in this versionEnergy consumption (MJ/t-km, kWh/t-km) …
Changed in this versionEnergy consumption (MJ/p-km, kWh/p-km) …
Changed in this versionEnergy consumption (MJ/m3-km, kWh/m3-km) …
Changed in this versionCO2 (g/km) …
Changed in this versionCO2 (g/t-km) …
Changed in this versionCO2 (g/p-km) …
Changed in this versionCO2 (g/m3-km) …
Changed in this versionElectric and zero emission ranges
Changed in this versionActual charge depleting range (km) …
Changed in this versionEquivalent all electric range (km) …
Changed in this versionZero CO2 emission range (km) …
Changed in this versionSoftware information
Changed in this versionSimulation tool version (X.X.X) …
Changed in this versionDate and time of the simulation …
Changed in this versionCryptographic hash simulation tool input information and input data of the primary vehicle (if applicable) …
Changed in this versionCryptographic hash of the manufacturer’s record file of the primary vehicle (if applicable) …
Changed in this versionCryptographic hash of the vehicle information file as produced by the simulation tool (if applicable) …
Changed in this versionCryptographic hash of the simulation tool input information and input data …
Changed in this versionCryptographic hash of the manufacturer's records file …
Changed in this versionPART II
Vehicle, component, separate technical unit and systems data
Changed in this versionVehicle data
Changed in this versionVehicle identification number (VIN)…
Changed in this versionVehicle category (N2, N3, M3)…
Changed in this versionAxle configuration…
Changed in this versionTechnically Permissible Maximum Laden Mass (t)…
Changed in this versionVehicle group in accordance with Annex I… 1.1.5a. Vehicle (sub-)group for CO2 standards…
Changed in this versionName and address(es) of manufacturer(s)…
Changed in this versionModel…
Changed in this versionCorrected actual mass (kg)…
Changed in this versionVocational vehicle (yes/no)…
Changed in this versionZero emission heavy-duty vehicle (yes/no)… 1.1.11 Hybrid electric heavy-duty vehicle (yes/no)… 1.1.12 Dual-fuel vehicle (yes/no)… 1.1.12a. Waste Heat recovery (yes/no)…
Changed in this versionSleeper cab (yes/no)…
Changed in this versionHEV architecture (e.g. P1, P2)…
Changed in this versionPEV architecture (e.g. E2, E3)…
Changed in this versionOff-vehicle charging capability (yes/no)…
Changed in this version–
Changed in this versionOff-vehicle charging maximum power (kW)…
Changed in this versionVehicle technology exempted from Article 9…
Changed in this versionClass of bus (e.g. I, I+II etc.)…
Changed in this versionTotal number of registered passengers…
Changed in this versionComponent, separate technical unit and systems data
Changed in this versionEngine rated power (kW)…
Changed in this versionEngine capacity (ltr)…
Changed in this versionFuel type (Diesel CI/CNG PI/LNG PI)…
Changed in this versionTransmission values (measured/standard)…
Changed in this versionTransmission type (SMT, AMT, APT, none)…
Changed in this versionNo. of gears…
Changed in this versionRetarder (yes/no)…
Changed in this versionAxle ratio…
Changed in this versionAverage rolling resistance coefficient (RRC) of all tyres of the motor vehicle:… 1.2.10a. Tyre dimension for each axle of the motor vehicle… 1.2.10b. Fuel efficiency class(es) of the tyres in accordance with Regulation (EU) 2020/740 for each axle of the motor vehicle… 1.2.10c. Tyre certification number for each axle of the motor vehicle…
Changed in this versionEngine stop-start during vehicle stops (yes/no)…
Changed in this versionEco-roll without engine stop-start (yes/no)…
Changed in this versionEco-roll with engine stop-start (yes/no)…
Changed in this versionPredictive cruise control (yes/no)… 1.2.15 Electric machine system(s) total rated propulsion power (kW)… 1.2.16 Electric machine system total maximum continuous propulsion power (kW)… 1.2.17 REESS total storage capacity (kWh)… 1.2.18 REESS useable storage capacity in simulation (kWh)…
Changed in this versionAuxiliary configuration
Changed in this versionSteering pump technology…
Changed in this versionElectric system 1.3.2.1 Alternator technology (conventional, smart, no alternator)… 1.3.2.2 Max alternator power (smart alternator) (kW)… 1.3.2.3 Electric storage capacity (smart alternator) (kWh)…
Changed in this versionPneumatic system 1.3.3.1 Smart compression system… 1.3.3.2 Smart regeneration system…
Changed in this versionHVAC system 1.3.4.1 System configuration… 1.3.4.2 Auxiliary heater power (kW)… 1.3.4.3 Double glazing (yes/no)…
Changed in this versionCO2 emissions and fuel consumption of the vehicle (for each mission profile and loading combination, for OVC-HEVs additionally for charge depleting, charge sustaining mode and weighted)
Changed in this versionSimulation parameters 2.1.1 Mission profile… 2.1.2 Payload (kg)… 2.1.3 Passenger information 2.1.3.1 Number of passengers in simulation… (-) 2.1.3.2 Mass of passengers in simulation… (kg) 2.1.4 Total vehicle mass in simulation (kg)…
Changed in this versionOVC mode (charge depleting, charge sustaining, weighted)…
Changed in this versionAverage speed (km/h)…
Changed in this versionFuel and energy consumption results (per fuel type and electric energy)
Changed in this versionFuel consumption (g/km)…
Changed in this versionFuel consumption (g/t-km)…
Changed in this versionFuel consumption (g/p-km)…
Changed in this versionFuel consumption (g/m3-km)…
Changed in this versionFuel consumption (l/100km)…
Changed in this versionFuel consumption (l/t-km)…
Changed in this versionFuel consumption (l/p-km)…
Changed in this versionFuel consumption (l/m3-km)…
Changed in this versionEnergy consumption (MJ/km, kWh/km)…
Changed in this versionEnergy consumption (MJ/t-km, kWh/t-km)…
Changed in this versionEnergy consumption (MJ/p-km, kWh/p-km)…
Changed in this versionEnergy consumption (MJ/m3-km, kWh/m3-km)…
Changed in this versionCO2 results (for each mission profile and loading combination)
Changed in this versionCO2 (g/km)…
Changed in this versionCO2 (g/t-km)…
Changed in this versionCO2 (g/p-km)…
Changed in this versionCO2 (g/m3-km)…
Changed in this versionElectric Ranges
Changed in this versionActual charge depleting range (km)…
Changed in this versionEquivalent all electric range (km)…
Changed in this versionZero CO2 emission range (km)…
Changed in this versionWeighted results
Changed in this versionSpecific CO2 emissions (gCO2/t-km)…
Changed in this versionSpecific electric energy consumption (kWh/t-km)…
Changed in this versionAverage payload value (t)…
Changed in this versionSpecific CO2 emissions (gCO2/p-km)…
Changed in this versionSpecific electric energy consumption (kWh/p-km)…
Changed in this versionAverage passenger count (p)…
Changed in this versionActual charge depleting range (km)…
Changed in this versionEquivalent all electric range (km)…
Changed in this versionZero CO2 emission range (km)…
Changed in this versionSoftware information
Changed in this versionSimulation tool version…
Changed in this versionDate and time of the simulation…
Changed in this versionCryptographic hash of the simulation tool input information and input data of the primary vehicle (if applicable)…
Changed in this versionCryptographic hash of the manufacturer’s records file of the primary vehicle (if applicable)…
Changed in this versionCryptographic hash of the vehicle simulation tool input information and input data…
Changed in this versionCryptographic hash of the manufacturer's records file…
Changed in this versionCryptographic hash of the customer information file…
Changed in this versionPART III
In the case of a primary vehicle:
Changed in this versionInput data and input information as set out in Annex III for the primary vehicle except: engine fuel map; engine correction factors WHTC_Urban, WHTC_Rural, WHTC_Motorway, BFColdHot, CFRegPer; torque converter characteristics; loss maps for transmission, retarder, angle drive and axle; electric power consumption map(s) for electric motor systems and IEPC; electric loss parameters for REESS
Changed in this versionFor each mission profile and loading condition:
Changed in this versionTotal vehicle mass in simulation (kg)…
Changed in this versionNumber of passengers in simulation (-)…
Changed in this versionEnergy consumption (MJ/km)…
Changed in this versionSoftware information
Changed in this versionSimulation tool version…
Changed in this versionDate and time of the simulation…
Changed in this versionCryptographic hashes
Changed in this versionCryptographic hash of the manufacturers records file of the primary vehicle…
Changed in this versionCryptographic hash of the vehicle information file…
Changed in this versionFor each interim, complete or completed vehicle
Changed in this versionInput data and input information as set out for the complete or completed vehicle in Annex III and which was provided by the particular manufacturer
Changed in this versionSoftware information
Changed in this versionSimulation tool version…
Changed in this versionDate and time of the simulation…
Changed in this versionCryptographic hashes
Changed in this versionCryptographic hash of the vehicle information file…
Changed in this versionANNEX V
VERIFYING ENGINE DATA
1. Introduction
2. Definitions
‘engine CO2-family’ means a manufacturer's grouping of engines, as defined in paragraph 1 of Appendix 3;
Changed in this version‘CO2-parent engine’ means an engine selected from an engine CO2-family as specified in Appendix 3;
Changed in this version‘NCV’ means net calorific value of a fuel as specified in paragraph 3.2;
Changed in this version‘specific mass emissions’ means the total mass emissions divided by the total engine work over a defined period expressed in g/kWh;
Changed in this version‘specific fuel consumption’ means the total fuel consumption divided by the total engine work over a defined period expressed in g/kWh;
Changed in this version‘FCMC’ means fuel consumption mapping cycle;
Changed in this version‘Full load’ means the delivered engine torque/power at a certain engine speed when the engine is operated at maximum operator demand;
Changed in this version‘Waste Heat Recovery system’ or ‘WHR system’ means all devices converting energy from the exhaust gas or from operating fluids in engine cooling systems into electrical or mechanical energy;
Changed in this version‘WHR system with no external output’ or ‘WHR_no_ext’ means a WHR system which generates mechanical energy and is mechanically connected to the engine crankshaft in order to feed its generated energy directly back to the engine crankshaft;
Changed in this version‘WHR system with external mechanical output’ or ‘WHR_mech’ means a WHR system which generates mechanical energy and feeds it to other elements in the vehicle’s drivetrain than the engine or to a rechargeable storage;
Changed in this version‘WHR system with external electrical output’ or ‘WHR_elec’ means a WHR system which generates electrical energy and feeds it to the vehicle’s electric circuit or to a rechargeable storage;
Changed in this version‘P_WHR_net’ means the net power generated by a WHR system in accordance with point 3.1.6;
Changed in this version‘E_WHR_net’ means the net energy generated by a WHR system over a certain amount of time determined by integrating P_WHR_net; The definitions set out in paragraphs 3.1.5 and 3.1.6 of Annex 4 to UN Regulation No. 49 shall not apply.
Changed in this version3. General requirements
3.1 Test conditions
3.1.1 Laboratory test conditions
The parameter ‘fa’ describing the laboratory test conditions, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49, shall be within the following limits: 0,96 ≤ fa ≤ 1,04.
Changed in this versionThe absolute temperature (Ta) of the engine intake air expressed in Kelvin, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49 shall be within the following limits: 283 K ≤ Ta ≤ 303 K.
Changed in this versionThe atmospheric pressure expressed in kPa, determined in accordance with paragraph 6.1 of Annex 4 to UN Regulation No. 49 shall be within the following limits: 90 kPa ≤ ps ≤ 102 kPa. If tests are performed in test cells that are able to simulate barometric conditions other than those existing in the atmosphere at the specific test site, the applicable fa value shall be determined with the simulated values of atmospheric pressure by the conditioning system. The same reference value for the simulated atmospheric pressure shall be used for the intake air and exhaust path and all other relevant engine systems. The actual value of the simulated atmospheric pressure for the intake air and exhaust path and all other relevant engine systems shall be within the limits specified in subpoint (3). In cases where the ambient pressure in the atmosphere at the specific test site exceeds the upper limit of 102 kPa, tests in accordance with this Annex may still be performed. In this case tests shall be performed with the specific ambient air pressure in the atmosphere. In cases where the test cell has the ability to control temperature, pressure and/or humidity of engine intake air independent of the atmospheric conditions the same settings for those parameters shall be used for all testruns performed for the purpose of certification of one specific engine CO2-family defined in accordance with Appendix 3 to this Annex.
Changed in this version3.1.2 Engine installation
fan;
Changed in this versionelectrically powered auxiliaries/equipment necessary for operating the engine system
Changed in this version3.1.3 Crankcase emissions
3.1.4 Engines with charge air-cooling
3.1.5 Engine cooling system
During all testruns the engine cooling system used on the test bed shall be operated under conditions which are representative for in-vehicle application at reference ambient conditions. The reference ambient conditions are defined as 293 K for air temperature and 101,3 kPa for pressure.
Changed in this versionThe engine cooling system should be equipped with thermostats according to the manufacturer specification for vehicle installation. If either a non-operational thermostat is installed or no thermostat is used, subpoint (3) shall apply. The setting of the cooling system shall be performed in accordance with subpoint (4).
Changed in this versionIf no thermostat is used or a non-operational thermostat is installed, the test bed system shall reflect the behavior of the thermostat under all test conditions. The setting of the cooling system shall be performed in accordance with subpoint (4).
Changed in this versionThe engine coolant flow rate (or alternatively the pressure difference across the engine side of the heat exchanger) and the engine coolant temperature shall be set to a value representative for in-vehicle application at reference ambient conditions when the engine is operated at rated speed and full load with the engine thermostat in fully open position. This setting defines the coolant reference temperature. For all testruns performed for the purpose of certification of one specific engine within one engine CO2-family, the cooling system setting shall not be changed, neither on the engine side nor on the test bed side of the cooling system. The temperature of the test bed side cooling medium shall be kept reasonably constant by good engineering judgement. The cooling medium on the test bed side of the heat exchanger shall not exceed the nominal thermostat opening temperatur downstream of the heat exchanger.
Changed in this versionFor all testruns performed for the purpose of certification of one specific engine within one engine CO2-family the engine coolant temperature shall be maintained between the nominal value of the thermostat opening temperature declared by the manufacturer and the coolant reference temperature in accordance with subpoint (4) as soon as the engine coolant has reached the declared thermostat opening temperature after engine cold start.
Changed in this version►M3
For the WHTC coldstart test performed in accordance with paragraph 4.3.3, the specific initial conditions are specified in paragraphs 7.6.1 and 7.6.2 of Annex 4 to UN Regulation No. 49. ◄ If simulation of the thermostat behaviour in accordance with subpoint (3) is applied, there shall be no coolant flow across the heat exchanger as long as the engine coolant has not reached the declared nominal thermostat opening temperature after cold start.
Changed in this version3.1.6 Set up of WHR systems
3.1.6.1 For parameters listed in 3.1.6.2. installation on the test bed shall not result in better performance of the WHR system related to generated power by the system as compared to the specifications for in-use installation in a vehicle. All other WHR related systems used on the test bed shall be operated under conditions which are representative for in-vehicle application at reference ambient
3.1.6.2 The engine test setup shall reflect the worst-case condition with regards to temperature and energy content transferred from excess energy to the WHR system. The following parameters have to be set to reflect the worst-case condition and need to be recorded in accordance with Figure 1a and have to be reported in the information document drawn up in accordance with the model set out in Appe
The distance between the last after treatment system and the heat exchangers for evaporation of working fluids of WHR systems (boilers), measured in the direction downstream of the engine (LEW), shall be equal to or greater than the maximum distance (LmaxEW) specified by the manufacturer of the WHR system for in-use installation in vehicles.
Changed in this versionIn the case of WHR systems with turbine(s) in the exhaust gas flow, the distance between the engine outlet and the entry into the turbine (LET) shall be equal or larger than the maximum distance (LmaxET) specified by the manufacturer of the WHR system for in-use installation in vehicles.
Changed in this versionFor WHR systems operated in a cyclic process using a working fluid:
Changed in this versionThe total pipe length between evaporator and expander (LHE) shall be equal or longer than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxHE);
Changed in this versionThe total pipe length between expander and condenser (LEC) shall be equal or shorter than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxEC);
Changed in this versionThe total pipe length between condenser and evaporator (LCE) shall be equal or shorter than defined by the manufacturer as maximum distance for in-use installation in vehicles (LmaxCE);
Changed in this versionThe pressure pcond of the working fluid before entering the condenser shall correspond to the in-use application in vehicles at reference ambient conditions but shall in any case not be lower than the ambient pressure in the test cell minus 5 kPa, unless the manufacturer demonstrates that a lower pressure can be maintained over vehicle lifetime in-use;
Changed in this versionThe cooling power on the test bed for cooling the WHR condenser shall be limited to a maximum value of Pcool = k × (tcond - 20 °C). Pcool shall be measured either on the working fluid side or on the test bed coolant side. Where tcond is defined as the condensation temperature (in °C) of the fluid at pcond. k = f0 + f1 × Vc. With: Vc is the engine displacement in litres (rounded to 2 places to the right of the decimal point) f0 = 0,6 kW/K f1 = 0,05 kW/(K*l);
Changed in this versionFor cooling the WHR condenser on the test bed either liquid-cooling or air-cooling is allowed. In the case of an air-cooled condenser, the system shall be cooled with the same fan (if applicable) as installed on the vehicle and under the reference ambient conditions stated in subpoint 3.1.6.1. above. In the case of an air-cooled condenser, the limitation for cooling power stated in subpoint (v) above shall apply, where the actual cooling power shall be measured on the working fluid side of the heat condenser. Where the power for driving such a fan is provided from an external power source, the respective actual power consumed by the fan shall be considered as power delivered to the WHR system when determining the net power in accordance with subpoint (f) below.
Changed in this versionFigure 1a
Definitions of minimum and maximum distances for WHR compone
Other WHR systems taking heat energy from the exhaust or cooling system shall be set up in accordance with the provisions in subpoint (c). The “evaporator” in subpoint (c) refers to the heat exchanger to transfer excess heat to the WHR device. The “expander” in subpoint (c) refers to the device converting the energy.
Changed in this versionAll pipe diameters of WHR systems shall be equal or smaller than the diameters defined for in-use.
Changed in this versionFor WHR_mech systems the net mechanical power shall be measured at the rotational engine speed expected at 60 km/h. If different transmission ratios are expected to be used, the rotational speed shall be calculated with the average over these transmission ratios. The mechanical or electrical power generated by a WHR system shall be measured with measurement equipment meeting the respective requirements set out in Table 2.
Changed in this versionThe net electric power is the sum of the electric power delivered by the WHR system to an external power sink or rechargeable storage, minus the electric power delivered to the WHR system from an external power source or rechargeable storage. The net electric power shall be measured as DC power, i.e. after the conversion from AC to DC.
Changed in this versionThe net mechanical power is the sum of the mechanical power delivered by the WHR system to an external power sink or rechargeable storage (if applicable), minus the mechanical power delivered to the WHR system from an external power source or rechargeable storage.
Changed in this versionAll transmission systems for electrical and mechanical power necessary for the vehicle in-use shall be set up for the measurement during the engine testing (e.g. cardan shafts or belt drives for mechanical connection, AC/DC converters and DC/DC voltage transformers). If a transmission system applied in the vehicle is not part of the test set up the net electrical or mechanical power measured shall be decreased accordingly by multiplication by a generic efficiency factor for each separate transmission system. The following generic efficiencies shall be applied for transmission systems not included in the set up: Table 1 Generic efficiencies of transmission systems for WHR power
| Type of transmission | Efficiency factor for WHR power |
|---|---|
| Gear stage | 0,96 |
| Belt drive | 0,92 |
| Chain drive | 0,94 |
| DC/DC converter | 0,95 |
3.2 Fuels
3.2.1 For dual-fuel engines the respective reference fuels for the engine systems under test shall be selected from the fuel types listed in Table 1. One of the two reference fuels shall always be B7 and the other reference fuel shall be G25, GR or LPG Fuel B.
3.3 Lubricants
3.4 Fuel flow measurement system
3.4.1 Special requirements for dual-fuel engines
3.5 Measurement equipment specifications
The fuel type for which the fuel mass flow shall be determined by the measurement system subject to verification of the requirements defined in Table 2 shall be the primary fuel. The other fuel type shall be the secondary fuel.
Changed in this versionThe maximum predicted value expected during all test runs for the secondary fuel shall be converted to the maximum predicted value expected during all test runs for the primary fuel by application of the following equation: mf* mp,seco = mfmp,seco × NCVseco / NCVprim where: mf*
| mp,seco | = | maximum predicted massflow value of the secondary fuel converted to the primary fuel |
|---|---|---|
| mfmp,seco | = | maximum predicted massflow value of the secondary fuel |
| NCVprim | = | NCV of the primary fuel determined in accordance with point 3,2 [MJ/kg] |
| NCVseco | = | NCV of the secondary fuel determined in accordance with point 3,2 [MJ/kg] |
The maximum predicted overall value, mfmp,overall, expected during all test runs shall be determined by application of the following equation: mfmp,overall = mfmp,prim + mf* mp,seco where:
| mfmp,prim | = | maximum predicted massflow value of the primary fuel |
mf*
mp,seco | = | maximum predicted massflow value of the secondary fuel converted to the primary fuel
Changed in this versionThe ‘max calibration’ values shall be 1.1 times the maximum predicted overall value, mfmp,overall, determined in accordance with subpoint (3) above. ‘xmin ’, used for calculation of the intercept value in Table 2, shall be 0,9 times the minimum predicted value expected during all test runs for the respective measurement system. The signal delivery rate of the measurement systems listed in Table 2, except for the fuel mass flow measurement system, shall be at least 5 Hz (≥ 10 Hz recommended). The signal delivery rate of the fuel mass flow measurement system shall be at least 2 Hz. All measurement data shall be recorded with a sample rate of at least 5 Hz (≥ 10 Hz recommended).
Changed in this version3.5.1 Measurement equipment verification
4. Testing procedure
4.1 Overview of testruns to be performed
4.2 Allowed changes to the engine system
4.2.1 Special requirements for dual-fuel engines
4.3 Testruns
4.3.1 Engine full load curve
4.3.2 Engine motoring curve
4.3.2.1 Special requirements for WHR systems
4.3.3 WHTC test
4.3.3.1 Measurement signals and data recording
4.3.3.2 Special requirements for WHR systems
4.3.4 WHSC test
4.3.4.1 Measurement signals and data recording
4.3.4.2 Special requirements for WHR systems
4.3.5 Fuel consumption mapping cycle (FCMC)
4.3.5.1 Handling of interruptions during the FCMC
the procedure shall be continued as described in paragraph 4.3.5.1.1
Changed in this versionthe whole FCMC shall be repeated in accordance with paragraphs 4.3.5.4 and 4.3.5.5
Changed in this version4.3.5.1.1 Provisions for continuing the FCMC
4.3.5.2 Grid of target setpoints
4.3.5.2.1 Definition of target engine speed setpoints
Base engine speed 1: nidle
Changed in this versionBase engine speed 2: nA = n57 – 0,05 × (n95h – nidle)
Changed in this versionBase engine speed 3: nB = n57 + 0,08 × (n95h – nidle)
Changed in this versionBase engine speed 4: n95h The potential distances between the speed setpoints shall be determined by the following equations:
Changed in this versiondnidleA_44 = (nA – nidle) / 4
Changed in this versiondnB95h_44 = (n95h – nB) / 4
Changed in this versiondnidleA_35 = (nA – nidle) / 3
Changed in this versiondnB95h_35 = (n95h – nB) / 5
Changed in this versiondnidleA_53 = (nA – nidle) / 5
Changed in this versiondnB95h_53 = (n95h – nB) / 3 The absolute values of potential deviations between the two sections shall be determined by the following equations:
Changed in this versiondn44 = ABS(dnidleA_44 – dnB95h_44)
Changed in this versiondn35 = ABS(dnidleA_35 – dnB95h_35)
Changed in this versiondn53 = ABS(dnidleA_53 – dnB95h_53) The 6 additional target engine speed setpoints shall be determined in accordance with the following provisions:
Changed in this versionIf dn44 is smaller than or equal to (dn35 + 5) and also smaller than or equal to (dn53 + 5), the 6 additional target engine speeds shall be determined by dividing each of the two ranges, one from nidle to nA and the other from nB to n95h, into 4 equidistant sections.
Changed in this versionIf (dn35 + 5) is smaller than dn44 and also dn35 is smaller than dn53, the 6 additional target engine speeds shall be determined by dividing the range from nidle to nA into 3 equidistant sections and the range from nB to n95h, into 5 equidistant sections.
Changed in this versionIf (dn53 + 5) is smaller than dn44 and also dn53 is smaller than dn35, the 6 additional target engine speeds shall be determined by dividing the range from nidle to nA into 5 equidistant sections and the range from nB to n95h, into 3 equidistant sections. Figure 1 exemplarily illustrates the definition of the target engine speed setpoints according to subpoint (1) above.
Changed in this versionFigure 1
Definition of speed setpoints
4.3.5.2.2 Definition of target torque setpoints
Figure 2
Definition of torque setpoints
4.3.5.3 Measurement signals and data recording
engine speed
Changed in this versionengine torque corrected in accordance with paragraph 3.1.2
Changed in this versionfuel mass flow consumed by the whole engine system in accordance with paragraph 3.4
Changed in this versionGaseous pollutants according to the definitions in
►M3
UN Regulation No. 49 ◄ .
►M3
Particulate pollutants, methane and ammonia emissions are not required to be monitored during the FCMC test run. ◄ The measurement of gaseous pollutants shall be carried out in accordance with paragraphs 7.5.1, 7.5.2, 7.5.3, 7.5.5, 7.7.4, 7.8.1, 7.8.2, 7.8.4 and 7.8.5 of Annex 4 to
►M3
UN Regulation No. 49 ◄ . For the purpose of paragraph 7.8.4 of Annex 4 to
►M3
UN Regulation No. 49 ◄ , the term ‘test cycle’ in the paragraph referred to shall be the complete sequence from preconditioning in accordance with paragraph 4.3.5.4 to ending of the test sequence in accordance with paragraph 4.3.5.5.
Changed in this version4.3.5.3.1 Special requirements for WHR systems
4.3.5.4 Preconditioning of the engine system
4.3.5.5 Test sequence
The engine shall be operated for 95 ± 3 seconds at each target setpoint. The first 55 ± 1 seconds at each target setpoint are considered as a stabilization period,.
►M3
During the following period of 30±1 seconds the engine shall be controlled as follows: ◄
Changed in this versionThe engine speed mean value shall be held at the target engine speed setpoint within ± 1 percent of the highest target engine speed.
Changed in this versionExcept for the points at full load, the engine torque mean value shall be held at the target torque setpoint within a tolerance of ± 20 Nm or ± 2 percent of the overall maximum torque, Tmax_overall, whichever is greater. The recorded values in accordance with paragraph 4.3.5.3 shall be stored as averaged value over the period of 30 ± 1 seconds. The remaining period of 10 ± 1 seconds may be used for data post-processing and storage if necessary. During this period the engine target setpoint shall be kept.
Changed in this versionAfter the measurement at one target setpoint is completed, the target value for engine speed shall be kept constant within ± 20 min– 1 of the target engine speed setpoint and the target value for torque shall be decreased linearly within 20±1 seconds to match the next lower target torque setpoint. Then the measurement shall be performed according to subpoint (1).
Changed in this versionAfter the zero torque setpoint has been measured in subpoint (1), the target engine speed shall be decreased linearly to the next lower target engine speed setpoint while at the same time the operator demand shall be increased linearly to the maximum value within 20 to 46 seconds. If the next target setpoint is reached within less than 46 seconds, the remaining time up to 46 seconds shall be used for stabilisation. Then the measurement shall be performed by starting the stabilisation procedure in accordance with subpoint (1) and afterwards the target torque setpoints at constant target engine speed shall be adjusted in accordance with subpoint (2). Figure 3 illustrates the three different steps to be performed at each measurement setpoint for the test according to subpoint (1) above.
Changed in this versionFigure 3
Steps to be performed at each measurement setpoint
Figure 4
Sequence of steady state measurement setpoints
4.3.5.6 Data evaluation for emission monitoring
4.3.5.6.1 Definition of control area
4.3.5.6.1.1 Engine speed range for the control area
The engine speed range for the control area shall be defined based on the engine full load curve of the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3 to this Annex and recorded in accordance with paragraph 4.3.1.
Changed in this versionThe control area shall include all engine speeds greater than or equal to the 30th percentile cumulative speed distribution, determined from all engine speeds including idle speed sorted in ascending order, over the hotstart WHTC test cycle performed in accordance with paragraph 4.3.3 (n30) for the engine full load curve referred to the subpoint (1).
Changed in this versionThe control area shall include all engine speeds lower than or equal to nhi determined from the engine full load curve referred to in the subpoint (1)
Changed in this version4.3.5.6.1.2 Engine torque and power range for the control area
The lower boundary of the engine torque range for the control area shall be defined based on the engine full load curve of the engine with the lowest rating of all engines within the engine CO2-family and recorded in accordance with paragraph 4.3.1.
Changed in this versionThe control area shall include all engine load points with a torque value greater than or equal to 30 percent of the maximum torque value determined from the engine full load curve referred to in subpoint (1).
Changed in this versionNotwithstanding the provisions of subpoint (2), speed and torque points below 30 percent of the maximum power value, determined from the engine full load curve referred to in subpoint (1), shall be excluded from the control area.
Changed in this versionNotwithstanding the provisions of subpoints (2) and (3), the upper boundary of the control area shall be based on the engine full load curve of the CO2-parent engine of the engine CO2-family defined in accordance with Appendix 3 to this Annex and recorded in accordance with paragraph 4.3.1. The torque value for each engine speed determined from the engine full load curve of the CO2-parent engine shall be increased by 5 percent of the overall maximum torque, Tmax_overall, defined in accordance with paragraph 4.3.5.2.2. The modified increased engine full load curve of the CO2-parent engine shall be used as upper boundary of the control area. Figure 5 exemplarily illustrates the definition of the engine speed, torque and power range for the control area.
Changed in this versionFigure 5
Definition of the engine speed, torque and power range for the control area exemplarily
4.3.5.6.2 Definition of the grid cells
The outer boundaries of the grids are aligned to the control area defined according to paragraph 4.3.5.6.1.
Changed in this version2 vertical lines spaced at equal distance between engine speeds n30 and nhi for 9 cell grids, or 3 vertical lines spaced at equal distance between engine speeds n30 and nhi for 12 cell grids.
Changed in this version2 lines spaced at equal distance of engine torque (i.e. 1/3) at each vertical line within the control area defined in accordance with point 4.3.5.6.1. All engine speed values in min-1 and all torque values in Newtonmeters defining the boundaries of the grid cells shall be rounded to 2 places to the right of the decimal point in accordance with ASTM E 29-06. Figure 6 exemplarily illustrates the definition of the grid cells for the control area in the case of 9 cell grid.
Changed in this versionFigure 6
Definition of the grid cells for the control area exemplarily for 9 cell grid
4.3.5.6.3 Calculation of specific mass emissions
4.3.5.7 Validity of data
4.3.5.7.1 Requirements for validation statistics of the FCMC
4.3.5.7.2 Requirements for emission monitoring
Engines other than dual-fuel shall meet the applicable limit values in accordance with paragraph 5.2.2 of Annex 10 to UN Regulation 49.
Changed in this versionDual-fuel engines shall meet the applicable limits defined in Annex XVIII to Regulation (EU) No 582/2011, where reference to a pollutant emission limit defined in Annex I to Regulation (EU) 595/2009 shall be replaced by reference to the limit of the same pollutant in accordance with paragraph 5.2.2 of Annex 10 to UN/ECE Regulation 49. In the case that the number of engine speed and torque points within the same grid cell is less than 3, this point shall not apply for that specific grid cell.
Changed in this version5. Post-processing of measurement data
5.1 Calculation of engine work
5.2 Calculation of integrated fuel consumption
5.3 Calculation of specific fuel consumption figures
5.3.1 Specific fuel consumption figures for WHTC correction factor
urban: from cycle start to ≤ 900 seconds from cycle start
Changed in this versionrural: from > 900 seconds to ≤ 1 380 seconds from cycle start
Changed in this versionmotorway (MW): from > 1 380 seconds from cycle start to cycle end
Changed in this version5.3.1.1 Special requirements for dual-fuel engines
5.3.2 Specific fuel consumption figures for cold-hot emission balancing factor
5.3.2.1 Special requirements for dual-fuel engines
5.3.3 Specific fuel consumption figures over WHSC
5.3.3.1 Corrected specific fuel consumption figures over WHSC
5.3.3.2 Special provisions for B7 reference fuel
5.3.3.3 Special requirements for dual-fuel engines
5.4 Correction factor for engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis
5.4.1 Special requirements for dual-fuel engines
5.5 Special provisions for WHR systems
5.5.1 Calculation of integrated E_WHR_net
5.5.2 Calculation of specific E_WHR_net figures
5.5.2.1 Specific E_WHR_net figures for WHTC correction factor
5.5.2.2 Specific E_WHR_net figures for cold-hot emission balancing factor
5.5.3 WHR correction factor for engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis
6. Application of engine pre-processing tool
6.1 Input data for the engine pre-processing tool
6.1.1 Full load curve of the CO2-parent engine
6.1.2 Full load curve
6.1.3 Motoring curve of the CO2-parent engine
6.1.4 Fuel consumption map of the CO2-parent engine
6.1.4.1 Special requirements for dual-fuel engines
6.1.4.2 Special requirements for engines equipped with a WHR system
6.1.5 Specific fuel consumption figures for WHTC correction factor
6.1.5.1 Special requirements for dual-fuel engines
6.1.6 Specific fuel consumption figures for cold-hot emission balancing factor
6.1.6.1 Special requirements for dual-fuel engines
6.1.7 Correction factor for engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis
6.1.7.1 Special requirements for dual-fuel engines
6.1.8 NCV of test fuel
6.1.8.1 Special requirements for dual-fuel engines
6.1.9 Type of test fuel
6.1.9.1 Special requirements for dual-fuel engines
6.1.10 Engine idle speed of the CO2-parent engine
6.1.11 Engine idle speed
6.1.12 Engine displacement
6.1.13 Engine rated speed
6.1.14 Engine rated power
6.1.15 Manufacturer
6.1.16 Model
6.1.17 Certification Number
6.1.18 Dual-fuel
6.1.19 WHR_no_ext
6.1.20 WHR_mech
6.1.21 WHR_elec
6.1.22 Specific E_WHR_net figures for WHTC correction factor for WHR_mech systems
6.1.23 Specific E_WHR_net figures for cold-hot emission balancing factor for WHR_mech systems
6.1.24 Specific E_WHR_net figures for WHTC correction factor for WHR_elec systems
6.1.25 Specific E_WHR_net figures for cold-hot emission balancing factor for WHR_ elec systems
6.1.26 WHR correction factor for engines equipped with exhaust after-treatment systems that are regenerated on a periodic basis
Appendix 1
MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF AN ENGINE FAMILY
SECTION I
SECTION II
Appendix 2
Engine Information Document
Notes regarding filling in the tables:
PART 1
Essential characteristics of the (parent) engine and the engine types within an engine family
Notes:
Appendix to information document
Information on test conditions
1. Spark plugs
2. Ignition coil
3. Lubricant used
4. Test fuel used ( 12 )
5. Engine-driven equipment
6. Engine performance (declared by manufacturer)
6.1. ►M3 Engine test speeds for emissions test (for dual-fuel engines performed in dual-fuel mode) in accordance with Annex 4 to UN Regulation No. 49 ( 13 ) ◄
6.2. Declared values for power test (for dual-fuel engines performed in dual-fuel mode) in accordance with UN Regulation No. 85 ( 14 )
Appendix 3
Engine CO2-Family
1. Parameters defining the engine CO2-family
1.1. Combustion relevant geometric data
1.2. Air management relevant components
2. Choice of the CO2-parent engine
Appendix 4
Conformity of CO2 emissions and fuel consumption related properties
1. General provisions
2. Number of engines and engine CO2-families to be tested
3. Selection of engine CO2-families to be tested
4. Testrun to be performed
The laboratory test conditions in accordance with paragraph 3.1.1 of this Annex. The conditions in accordance with paragraph 3.1.1 are recommended and shall not be mandatory. Deviations may occur under certain ambient conditions at the testing site and should be minimized by the use of good engineering judgment.
Changed in this versionIn case reference fuel of the type B7 (Diesel / CI) in accordance with paragraph 3.2 of this Annex is used, the determination of the NCV in accordance with paragraph 3.2 of this Annex shall not be required.
Changed in this versionIn case market fuel or reference fuel other than B7 (Diesel / CI) is used, the NCV of the fuel shall be determined in accordance with the applicable standards defined in Table 1 of this Annex. With exemption of gas engines the NCV measurement shall be performed by only one lab independent from the engine manufacturer instead of two as required in accordance with paragraph 3.2 of this Annex.
►M1
NCV for reference gas fuels (G25/GR, LPG fuel B) shall be calculated in accordance with the applicable standards in Table 1 of this Annex from the fuel analysis submitted by the reference gas fuel supplier. ◄
Changed in this versionThe lubricating oil shall be the one filled during engine production and shall not be changed for the purpose of testing conformity of CO2 emissions and fuel consumption related properties.
Changed in this version5. Run-in of newly manufactured engines
6. Target value for assessment of conformity of the certified CO2 emissions and fuel consumption related properties
6.1 Special requirements for dual-fuel engines
7. Actual value for assessment of conformity of the certified CO2 emissions and fuel consumption related properties
8. Limit for conformity of one single test
9. Assessment of conformity of the certified CO2 emissions and fuel consumption related properties
Appendix 5
Determination of power consumption of engine components
1. Fan
Install the fan according to product instruction before the test starts.
Changed in this versionWarm up phase: The engine shall be warmed up according to the recommendation of the manufacturer and by practicing good engineering judgement (eg operating the engine for 20 minutes at mode 9, as defined in Table 1 of paragraph 7.2.2. of Annex 4 to
►M3
UN Regulation No. 49 ◄ ).
Changed in this versionStabilization phase: After the warm-up or optional warm-up step (v) is completed the engine shall be operated with minimum operator demand (motoring) at engine speed npref for 130 ± 2 seconds with the fan disengaged (nfan_disengage < 0,75 * nengine * rfan). The first 60 ± 1 seconds of this period are considered as a stabilization period, during which the actual engine speed shall be held within ± 5 min– 1 of npref.
Changed in this versionMeasurement phase: During the following period of 60 ± 1 seconds the actual engine speed shall be held within ± 2 min– 1 of npref and the coolant temperature within ± 5 °C while the torque for motoring the engine with the fan disengaged, the fan speed and the engine speed shall be recorded as an average value over this period of 60 ± 1 seconds. The remaining period of 10 ± 1 seconds shall be used for data post-processing and storage if necessary.
Changed in this versionOptional warmup phase: Upon manufacturer's request and according to good engineering judgement step (ii) can be repeated (e.g. if the temperature has dropped more than 5 °C)
Changed in this versionStabilization phase: After the optional warm-up is completed the engine shall be operated with minimum operator demand (motoring) at engine speed npref for 130 ± 2 seconds with the fan engaged (nfan_engage > 0,9 * nengine * rfan) The first 60 ± 1 seconds of this period are considered as a stabilization period, during which the actual engine speed shall be held within ± 5 min– 1 of npref.
Changed in this versionMeasurement phase: During the following period of 60 ± 1 seconds the actual engine speed shall be held within ± 2 min– 1 of npref and the coolant temperature within ± 5 °C while the torque for motoring the engine with the fan engaged, the fan speed and the engine speed shall be recorded as an average value over this period of 60 ± 1 seconds. The remaining period of 10±1 seconds shall be used for data post-processing and storage if necessary.
Changed in this versionSteps (iii) to (vii) shall be repeated at engine speeds n95h and nhi instead of npref, with an optional warmup step (v) before each stabilization step if needed to maintain a stable coolant temperature (± 5 °C), according to good engineering judgement.
Changed in this versionIf the standard deviation of all calculated Ci according to the equation below at the three speeds npref, n95h and nhi is equal or higher than 3 percent, the measurement shall be performed for all engine speeds defining the grid for the fuel mapping procedure (FCMC) according to paragraph 4.3.5.2.1. The actual fan constant shall be calculated from the measurement data according to the following equation: where:
| Ci | fan constant at certain engine speed |
|---|---|
| MDfan_disengage | measured engine torque at motoring with fan disengaged (Nm) |
| MDfan_engage | measured engine torque at motoring with fan engaged (Nm) |
| nfan_engage | fan speed with fan engaged (min– 1) |
| nfan_disengage | fan speed with fan disengaged min– 1) |
| rfan | ratio of the speed of the engine-side of the fan clutch to the speed of the crankshaft |
If the standard deviation of all calculated Ci at the three speeds npref, n95h and nhi is less than 3 %, an average value Cavg-fan determined over the three speeds npref, n95h and nhi shall be used for the fan constant. If the standard deviation of all calculated Ci at the three speeds npref, n95h and nhi is equal or higher than 3 %, individual values determined for all engine speeds according to point (ix) shall be used for the fan constant Cind-fan,i. The value of the fan constant for the actual engine speed Cfan, shall be determined by linear interpolation between the individual values Cind-fan,i of the fan constant. The engine torque for driving the fan shall be calculated according to the following equation: Mfan = Cfan · nfan
2 · 10– 6 where:
| Mfan | engine torque for driving fan (Nm) |
| Cfan | fan constant Cavg-fan or Cind-fan,i corresponding to nengine |
The mechanical power consumed by the fan shall be calculated from the engine torque for driving the fan and the actual engine speed. Mechanical power and engine torque shall be taken into account in accordance with paragraph 3.1.2.
Changed in this version2. Electric components/equipment
Appendix 6
1. Markings
2 Numbering
Appendix 7
Input parameters for the simulation tool
Introduction
Definitions
‘Parameter ID’:Unique identifier as used in the simulation tool for a specific input parameter or set of input data
| (2) | ‘Type’: |
Data type of the parameter
string …
sequence of characters in ISO8859-1 encoding
token …
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date …
date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer …
value with an integral data type, no leading zeros, e.g. ‘1800’
double, X …
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’ |
| integer … | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’ |
‘Unit’ …physical unit of the parameter
Changed in this versionSet of input parameters
Appendix 8
Important evaluation steps and equations of the engine pre-processing tool
1. Reading of input files and automatic check of input data
ANNEX VI — Standard torque loss values – other torque transferring components
VERIFYING TRANSMISSION, TORQUE CONVERTER, OTHER TORQUE TRANSFERRING COMPONENT AND ADDITIONAL DRIVELINE COMPONENT DATA
1. Introduction
2. Definitions
‘Transfer case’ means a device that splits the engine power of a vehicle and directs it to the front and rear drive axles. It is mounted behind the transmission and both front and rear drive shafts connect to it. It comprises either a gearwheel set or a chain drive system in which the power is distributed from the transmission to the axles. The transfer case will typically have the ability to shift between standard drive mode (front or rear wheel drive), high range traction mode (front and rear wheel drive), low range traction mode and neutral;
Changed in this version‘Gear ratio’ means the forward gear ratio of the speed of the input shaft (towards prime mover) to the speed of the output shaft (towards driven wheels) without slip (i = nin/nout );
Changed in this version‘Ratio coverage’ means the ratio of the largest to the smallest forward gear ratios in a transmission: φtot = imax/imin ;
Changed in this version‘Compound transmission’ means a transmission, with a large number of forward gears and/or large ratio coverage, composed of sub-transmissions, which are combined to use most power-transferring parts in several forward gears;
Changed in this version‘Main section’ means the sub-transmission that has the largest number of forward gears in a compound transmission;
Changed in this version‘Range section’ means a sub-transmission normally in series connection with the main section in a compound transmission. A range section usually has two shiftable forward gears. The lower forward gears of the complete transmission are embodied using the low range gear. The higher gears are embodied using the high range gear;
Changed in this version‘Splitter’ means a design that splits the main section gears in two (usually) variants, low- and high split gears, whose gear ratios are close compared to the ratio coverage of the transmission. A splitter can be a separate sub-transmission, an add-on device, integrated with the main section or a combination thereof;
Changed in this version‘Tooth clutch’ means a clutch where torque is transferred mainly by normal forces between mating teeth. A tooth clutch can either be engaged or disengaged. It is operated in load-free conditions, only (e.g., at gear shifts in a manual transmission);
Changed in this version‘Angle drive’ means a device that transmits rotational power between non-parallel shafts, often used with transversely oriented engine and longitudinal input to driven axle;
Changed in this version‘Friction clutch’ means clutch for transfer of propulsive torque, where torque is sustainably transferred by friction forces. A friction clutch can transmit torque while slipping, it can thereby (but does not have to) be operated at start-offs and at powershifts (retained power transfer during a gear shift);
Changed in this version‘Synchroniser’ means a type of tooth clutch where a friction device is used to equalise the speeds of the rotating parts to be engaged;
Changed in this version‘Gear mesh efficiency’ means the ratio of output power to input power when transmitted in a forward gear mesh with relative motion;
Changed in this version‘Crawler gear’ means a low forward gear (with speed reduction ratio that is larger than for the non-crawler gears) that is designed to be used infrequently, e.g., at low-speed manoeuvres or occasional up-hill start-offs;
Changed in this version‘Power take-off (PTO)’ means a device on a transmission or an engine to which an auxiliary driven device, e.g., a hydraulic pump, can be connected;
Changed in this version‘Power take-off drive mechanism’ means a device in a transmission that allows the installation of a power take-off (PTO);
Changed in this version‘Lock-up clutch’ means a friction clutch in a hydrodynamic torque converter; it can connect the input and output sides, thereby eliminating the slip.
►M3
In some cases permanent slip in fixed gears is intended, e.g. to prevent vibrations; ◄
Changed in this version►M3
‘Start-off clutch’ means a clutch that adapts speed between engine and driving wheels when the vehicle starts off. ◄ The start-off clutch is usually located between engine and transmission;
Changed in this version‘Synchronised Manual Transmission (SMT)’ means a manually operated transmission with two or more selectable speed ratios that are obtained using synchronisers. Ratio changing is normally achieved during a temporary disconnection of the transmission from the engine using a clutch (usually the vehicle start-off clutch);
Changed in this version‘Automated Manual Transmission or Automatic Mechanically-engaged Transmission (AMT)’ means an automatically shifting transmission with two or more selectable speed ratios that are obtained using tooth clutches (un-/synchronised). Ratio changing is achieved during a temporary disconnection of the transmission from the engine. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutch between engine and gearbox and the speed and torque of the engine. The system selects and engages the most suitable forward gear automatically, but can be overridden by the driver using a manual mode;
Changed in this version‘Dual Clutch Transmission (DCT)’ means an automatically shifting transmission with two friction clutches and several selectable speed ratios that are obtained by the use of tooth clutches. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutches and the speed and torque of the engine. The system selects the most suitable gear automatically, but can be overridden by the driver using a manual mode.
►M3
In some cases permanent slip in fixed gears is intended, e.g. to prevent vibrations; ◄
Changed in this version‘Retarder’ means an auxiliary braking device in a vehicle powertrain; aimed for permanent braking;
Changed in this version‘Case S’ means an Automatic Powershifting Transmission (APT) with serial arrangement of a torque converter and the connected mechanical parts of the transmission;
Changed in this version‘Case P’ means an APT with parallel arrangement of a torque converter and the connected mechanical parts of the transmission (e.g. in power split installations);
Changed in this version‘Automatic Powershifting Transmission (APT)’ means an automatically shifting transmission with more than two friction clutches and several selectable speed ratios that are obtained mainly by the use of those friction clutches. The ratio shifts are performed by an electronically controlled system managing the timing of the shift, the operation of the clutches and the speed and torque of the engine. The system selects the most suitable gear automatically, but can be overridden by the driver using a manual mode. Shifts are normally performed without traction interruption (friction clutch to friction clutch);
Changed in this version‘Oil conditioning system’ means an external system that conditions the oil of a transmission at testing. The system circulates oil to and from the transmission. The oil is thereby filtered and/or temperature conditioned;
Changed in this version‘Smart lubrication system’ means a system that will affect the load independent losses (also called spin losses or drag losses) of the transmission depending on the input torque and/or power flow through the transmission. Examples are controlled hydraulic pressure pumps for brakes and clutches in an APT, controlled variable oil level in the transmission, controlled variable oil flow/pressure for lubrication and cooling in the transmission. Smart lubrication can also include control of the oil temperature of the transmission, but smart lubrication systems that are designed only for controlling the temperature are not considered here, since the transmission testing procedure has fixed testing temperatures;
Changed in this version‘Transmission electric auxiliary’ means an electric auxiliary used for the function of the transmission during running steady state operation. A typical example is an electric cooling/lubrication pump (but not electric gear shift actuators and electronic control systems including electric solenoid valves, since they are low energy consumers, especially at steady state operation);
Changed in this version‘Oil type viscosity grade’ means a viscosity grade as defined by SAE J306;
Changed in this version‘Factory fill oil’ means the oil type viscosity grade that is used for the oil fill in the factory and which is intended to stay in the transmission, torque converter, other torque transferring component or in an additional driveline component for the first service interval;
Changed in this version‘Gearscheme’ means the arrangement of shafts, gearwheels and clutches in a transmission;
Changed in this version‘Powerflow’ means the transfer path of power from input to output in a transmission via shafts, gearwheels and clutches;
Changed in this version‘Differential’ means a device that splits a torque into two branches, e.g. for left- and right-hand side wheels, while allowing these branches to rotate at unequal speeds. The torque-splitting function can be biased or deactivated by a differential brake- or differential lock device (if applicable);
Changed in this version‘Case N’ means an APT without a torque converter.
Changed in this version3. Testing procedure for transmissions
Option 1: Measurement of the torque independent losses, calculation of the torque dependent losses.
Changed in this versionOption 2: Measurement of the torque independent losses, measurement of the torque loss at maximum torque and interpolation of the torque dependent losses based on a linear model
Changed in this versionOption 3: Measurement of the total torque loss.
| 3.1 | Option 1: Measurement of the torque independent losses, calculation of the torque dependent losses. |
The torque loss Tl ,in on the input shaft of the transmission shall be calculated by
▼M3
T
l,in (n
in ,T
in ,gear) = T
l,in,min_loss + f
T × T
in + f
loss_corr × T
in + T
l,in,min_el + f
el_corr × T
in + f
loss
tcc
× T
in
▼B
The correction factor for the torque dependent hydraulic torque losses shall be calculated by
The correction factor for the torque dependent electric torque losses shall be calculated by
The torque loss at the input shaft of the transmission caused by the power consumption of transmission electric auxiliary shall be calculated by
▼M3
The correction factor for the losses in a slipping TC lock-up clutch as defined in point 2(16) or slipping input side clutch as defined in point 2(20) shall be calculated by:
▼B
where:
Tl,in
=
Torque loss related to input shaft [Nm]
Tl,in,min_loss
=
Torque independent loss at minimum hydraulic loss level (minimum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm]
Tl,in,max_loss
=
Torque independent loss at maximum hydraulic loss level (maximum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm]
floss_corr
=
Loss correction for hydraulic loss level depending on input torque [-]
nin
=
Speed at the transmission input shaft (downstream of torque converter, if applicable) [rpm]
fT
=
Torque loss coefficient = 1 – ηT
Tin
=
Torque at the input shaft [Nm]
ηT
=
Torque dependent efficiency (to be calculated); for a direct gear fT = 0,007 (ηT = 0,993) [-]
fel_corr
=
Loss correction for electric power loss level depending on input torque [-]
Tl,in, el
=
Additional torque loss on input shaft by electric consumers [Nm]
Tl,in,min_el
=
Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm]
Tl,in,max_el
=
Additional torque loss on input shaft by electric consumers corresponding to maximum electric power [Nm]
Pel
=
Electric power consumption of electric consumers in transmission measured during transmission loss testing [W]
Tmax,in
=
Maximum allowed input torque for any forward gear in the transmission [Nm]
▼M3
floss_tcc
=
Loss correction factor for slipping torque converter (or input side) clutch
ntcc
=
Difference in speed between upstream and downstream side of slipping TC lock-up clutch as defined in point 2(16) or slipping input side clutch as defined in 2(20) [rpm] (speed downstream of the slipping clutch is the speed nin at the transmission input shaft)
▼B
3.1.1.
The torque dependent losses of a transmission system shall be determined as described in the following: In case of multiple parallel and nominally equal power flows, e.g., twin countershafts or several planet gearwheels in a planetary gear set, that can be treated as one power flow in this section.
3.1.1.1.
For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed:
3.1.1.2.
For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm:
external – external gear meshes
:
ηm = 0,986
external – internal gear meshes
:
ηm = 0,993
angle drive gear meshes
:
ηm = 0,97
(Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex)
3.1.1.3.
The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %.
3.1.1.4.
The total torque dependent efficiency η Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n
3.1.1.5.
The torque dependent loss coefficient fTg for the gear g shall be calculated by:
fTg = 1 – η Tg
3.1.1.6.
The torque dependent loss Tl,inTg on the input shaft for gear g shall be calculated by:
Tl,inTg = fTg * Tin
3.1.1.7.
The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by:
where:
ηm,ring
=
Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-]
ηm,sun
=
Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-]
zsun
=
Number of teeth of the sun gearwheel of the range section [-]
zring
=
Number of teeth of the ring gearwheel of the range section [-]
The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4.
3.1.1.8.
For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. In this case, for each indirect gear g, the following steps shall be performed:
3.1.1.9.
Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni ) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction.
3.1.1.10.
For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by:
Nsun–carrier = Nsun
– Ncarrier
Nring–carrier = Nring
– Ncarrier
where:
Nsun
=
Rotational speed of sun gearwheel [rad/s]
Nring
=
Rotational speed of ring gearwheel [rad/s]
Ncarrier
=
Rotational speed of carrier [rad/s]
3.1.1.11.
The loss-producing powers in the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the power P shall be calculated by:
P 1 = N 1 · T 1
P 2 = N 2 · T 2
where:
P
=
Power of gear mesh [W]
N
=
Rotational speed of gearwheel [rad/s]
T
=
Torque of gearwheel [Nm]
For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by:
Pv,sun = Tsun · (Nsun
– Ncarrier ) = Tsun · Nsun/carrier
Pv,ring = Tring · (Nring
– Ncarrier ) = Tring · Nring/carrier
where:
Pv,sun
=
Virtual power of sun gearwheel [W]
Pv,ring
=
Virtual power of ring gearwheel [W]
Tsun
=
Torque of sun gearwheel [Nm]
Tcarrier
=
Torque of carrier [Nm]
Tring
=
Torque of ring gearwheel [Nm]
Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm :
Pi > 0 ⇒ Pi,adj = Pi
Pi < 0 ⇒ Pi,adj = Pi · η mi
where:
Padj
=
Loss-adjusted powers of the gear meshes [W]
ηm
=
Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-]
For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring :
Pv,i ≥ 0 ⇒ Pi,adj = Pv,i
Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring
where:
ηmsun
=
Torque dependent efficiency of sun-to-planet [-]
ηmring
=
Torque dependent efficiency of ring-to-planet [-]
3.1.1.12.
All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss of the transmission system referring to the input power:
Pm,loss = ΣPi,adj
where:
i
=
All gearwheels with a fix rotational axis [-]
Pm,loss
=
Torque dependent gear mesh power loss of the transmission system [W]
3.1.1.13.
The torque dependent loss coefficient for bearings,
fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh
shall be added to receive the total torque dependent loss coefficient fT for the transmission system:
fT = fT,gearmesh + fT,bear
where:
fT
=
Total torque dependent loss coefficient for the transmission system [-]
fT,bear
=
Torque dependent loss coefficient for the bearings [-]
fT,gearmesh
=
Torque dependent loss coefficient for the gear meshes [-]
Pin
=
Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W]
3.1.1.14.
The torque dependent losses on the input shaft for the specific gear shall be calculated by:
Tl,inT = fT * Tin
where:
Tl,inT
=
Torque dependent loss related to input shaft [Nm]
Tin
=
Torque at the input shaft [Nm]
3.1.2.
The torque independent losses shall be measured in accordance with the procedure described in the following. 3.1.2.1. General requirements
The transmission used for the measurements shall be in accordance with the drawing specifications for series production transmissions and shall be new. Modifications to the transmission to meet the testing requirements of this Annex, e.g. for the inclusion of measurement sensors or adaption of an external oil conditioning system are permitted. The tolerance limits in this paragraph refer to measurement values without sensor uncertainty.
▼M1
Total tested time per transmission individual and gear shall not exceed 5 times the actual testing time per gear (allowing re-testing of transmission if needed due to measuring or rig error).
▼B
The same transmission individual may be used for a maximum of 10 different tests, e.g. for tests of transmission torque losses for variants with and without retarder (with different temperature requirements) or with different oils. If the same transmission individual is used for tests of different oils, the recommended factory fill oil shall be tested first. It is not permitted to run a certain test multiple times to choose a test series with the lowest results. Upon request of the approval authority the applicant for a certificate shall specify and prove the conformity with the requirements defined in this Annex. 3.1.2.2. Differential measurements
To subtract influences caused by the test rig setup (e.g. bearings, clutches) from the measured torque losses, differential measurements are permitted to determine these parasitic torques.
►M3
The measurements shall be performed at the same speed points and same test rig bearing temperature(s) ± 3 K used for the testing. ◄ The torque sensor measurement uncertainty shall be below 0,3 Nm. 3.1.2.3. Run-in
On request of the applicant a run-in procedure may be applied to the transmission. The following provisions shall apply for a run-in procedure.
3.1.2.3.1.
The procedure shall not exceed 30 hours per gear and 100 hours in total.
3.1.2.3.2.
The application of the input torque shall be limited to 100 % of maximum input torque.
3.1.2.3.3.
The maximum input speed shall be limited by the specified maximum speed for the transmission.
3.1.2.3.4.
The speed and torque profile for the run-in procedure shall be specified by the manufacturer.
3.1.2.3.5.
The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority.
3.1.2.3.6.
The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure.
3.1.2.4. Pre-conditioning
3.1.2.4.1.
Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed.
▼M3
3.1.2.4.2.
The pre-conditioning shall be performed without applied torque to the non driven shaft.
▼B
3.1.2.4.3.
The maximum input speed shall be limited by the specified maximum speed for the transmission.
3.1.2.4.4.
The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed
►M3
100 ◄ minutes.
3.1.2.4.5.
The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures.
3.1.2.5. Test conditions
3.1.2.5.1. Ambient temperature
The ambient temperature during the test shall be in a range of 25 °C ± 10 K. The ambient temperature shall be measured 1 m laterally from the transmission. The ambient temperature limit shall not apply for the run-in procedure. 3.1.2.5.2. Oil temperature
Except for the oil, no external heating is allowed. During measurement (except stabilization) the following temperature limits shall apply: For SMT/AMT/DCT transmissions, the drain plug oil temperature shall not exceed 83 °C when measuring without retarder and 87 °C with retarder mounted to the transmission. If measurements of a transmission without retarder are to be combined with separate measurements of a retarder, the lower temperature limit shall apply to compensate for the retarder drive mechanism and step-up gear and for the clutch in case of a disengageable retarder. For torque converter planetary transmissions and for transmissions having more than two friction clutches, the drain plug oil temperature shall not exceed 93 °C without retarder and 97 °C with retarder. To apply the above defined increased temperature limits for testing with retarder, the retarder shall be integrated in the transmission or have an integrated cooling or oil system with the transmission. During the run-in, the same oil temperature specifications as for regular testing shall apply. Exceptional oil temperature peaks up to 110 °C are allowed for the following conditions:
(1)
during run-in procedure up to maximum of 10 % of the applied run-in time,
(2)
during stabilization time.
The oil temperature shall be measured at the drain plug or in the oil sump. 3.1.2.5.3. Oil quality
New, recommended first fill oil for the European market shall be used in the test. The same oil fill may be used for run-in and torque measurement. 3.1.2.5.4. Oil viscosity
If multiple oils are recommended for first fill, they are considered to be equal if the oils have a kinematic viscosity within 10 % of each other at the same temperature (within the specified tolerance band for KV100). Any oil with lower viscosity than the oil used in the test shall be considered to result in lower losses for the tests performed within this option. Any additional first fill oil must fall either in the 10 % tolerance band or have lower viscosity than the oil in the test to be covered by the same certificate. 3.1.2.5.5. Oil level and conditioning
The oil level shall meet the nominal specifications for the transmission. If an external oil conditioning system is used, the oil inside the transmission shall be kept to the specified volume that corresponds to the specified oil level. To guarantee that the external oil conditioning system is not influencing the test, one test point shall be measured with the conditioning system both on and off. The deviation between the two measurements of the torque loss (= input torque) shall be less than 5 %. The test point is specified as follows:
(1)
gear = highest indirect gear,
▼M3
(2)
input speed = minimum of 60 % of the maximum input speed, not higher than 80 % of the maximum input speed,
▼B
(3)
temperatures as specified under 3.1.2.5.
For transmissions with hydraulic pressure control or a smart lubrication system, the measurement of torque independent losses shall be performed with two different settings: first with the transmission system pressure set to at least the minimum value for conditions with engaged gear and a second time with the maximum possible hydraulic pressure (see 3.1.6.3.1).
3.1.3.
Installation ▼M3
3.1.3.1.
The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft(s) shall rotate freely. In the case of a transmission with an integrated differential, e.g. for front-wheel drive operation, the output ends shall be allowed to be rotatably locked into each other (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement).
▼B
3.1.3.2.
The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°.
3.1.3.3.
The internal oil pump shall be included in the transmission.
3.1.3.4.
If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test.
3.1.3.5.
Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in
►M3
Annex IX ◄ to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off.
3.1.3.6.
Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test.
3.1.3.7.
The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8.
3.1.4.
Measurement equipmentThe calibration laboratory facilities shall comply with the requirements of either
►M3
IATF ◄ 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards. 3.1.4.1. Torque
The torque sensor measurement uncertainty shall be below 0,3 Nm. The use of torque sensors with higher measurement uncertainties is allowed if the part of the uncertainty exceeding 0,3 Nm can be calculated and is added to the measured torque loss as described in 3.1.8. Measurement uncertainty. 3.1.4.2. Speed
The uncertainty of the speed sensors shall not exceed ± 1 rpm. 3.1.4.3. Temperature
The uncertainty of the temperature sensors for the measurement of the ambient temperature shall not exceed ± 1,5 K. The uncertainty of the temperature sensors for the measurement of the oil temperature shall not exceed ± 1,5 K. 3.1.4.4. Pressure
The uncertainty of the pressure sensors shall not exceed 1 % of the maximum measured pressure. 3.1.4.5. Voltage
The uncertainty of the voltmeter shall not exceed 1 % of the maximum measured voltage. 3.1.4.6. Electric current
The uncertainty of the amperemeter shall not exceed 1 % of the maximum measured current.
3.1.5.
Measurement signals and data recordingAt least the following signals shall be recorded during the measurement:
(1)
Input torques [Nm]
(2)
Input rotational speeds [rpm]
(3)
Ambient temperature [°C]
(4)
Oil temperature [°C]
If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded:
(5)
Oil pressure [kPa]
If the transmission is equipped with transmission electric auxiliary, additionally to be recorded:
(6)
Voltage of transmission electric auxiliary [V]
(7)
Current of transmission electric auxiliary [A]
For differential measurements for the compensation of influences caused by the test rig setup, additionally shall be recorded:
(8)
Test rig bearing temperature [°C]
The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to reduce measurement errors.
3.1.6.
Test procedure3.1.6.1. Zero torque signal compensation:
The zero-signal of the torque sensor(s) shall be measured. For the measurement the sensor(s) shall be installed in the test rig. The drivetrain of the test rig (input & output) shall be free of load. The measured signal deviation from zero shall be compensated.
▼M3
3.1.6.2. The torque loss shall be measured for the following speed points (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 4 000 rpm and multiples of 10 of these values up to the maximum speed per gear in accordance with the specifications of the transmission or the last speed point before the defined maximum speed. It is permitted to measure additional intermediate speed points.
The speed ramp (time for the change between two speed points) shall not exceed 20 seconds.
▼B
3.1.6.3. Measurement sequence:
3.1.6.3.1.
If the transmission is equipped with smart lubrication systems and/or transmission electric auxiliaries, the measurement shall be conducted with two measurement settings of of these systems: A first measurement sequence (3.1.6.3.2. to 3.1.6.3.4.) shall be performed with the lowest power consumption by hydraulical and electrical systems when operated in the vehicle (low loss level). The second measurement sequence shall be performed with the systems set to work with the highest possible power consumption when operated in the vehicle (high loss level).
3.1.6.3.2.
The measurements shall be performed beginning with the lowest up to the highest speed.
3.1.6.3.3.
►M3
For each speed point a minimum of 5-second stabilisation time within the temperature limits defined in 3.1.2.5 is required. ◄ If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. Oil and ambient temperatures shall be recorded during the stabilization.
▼M3
3.1.6.3.4.
After the stabilisation time, the torque loss should be constant at the actual measured speed point over time. If so, the measurement signals listed in 3.1.5. shall be recorded for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.1.6.3.5.
Each measurement shall be performed two times per measurement setting.
3.1.7.
Measurement validation ▼M3
3.1.7.1.
The arithmetic mean values shall be calculated for each of the measurements of torque, speed, (if applicable) voltage and current. The measurements to be performed for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.1.7.2.
The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series.
3.1.7.3.
The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed:
▼M3
Tloss = T1,in(nin, Tin,gear)
▼B
Pel = I * U
It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.).
3.1.7.4.
The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values).
3.1.7.5.
The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken.
3.1.7.6.
If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear.
3.1.7.7.
The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken.
3.1.7.8.
If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear.
3.1.8.
Measurement uncertaintyThe part of the calculated total uncertainty UT,loss exceeding 0,3 Nm shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 0,3 Nm, then Tloss,rep = Tloss .
Tloss,rep = Tloss + MAX (0, (UT,loss
– 0,3 Nm)) The total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters:
(1)
Temperature effect
(2)
Parasitic loads
(3)
Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability)
The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’).
wpara = senspara * ipara
where:
Tloss
=
Measured torque loss (uncorrected) [Nm]
Tloss,rep
=
Reported torque loss (after uncertainty correction) [Nm]
UT,loss
=
Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm]
UT,in
=
Uncertainty of input torque loss measurement [Nm]
uTKC
=
Uncertainty by temperature influence on current torque signal [Nm]
wtkc
=
Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%]
uTK0
=
Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm]
wtk0
=
Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%]
Kref
=
Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K]
ΔK
=
Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used.
Tc
=
Current/measured torque value at torque sensor [Nm]
Tn
=
Nominal torque value of torque sensor [Nm]
ucal
=
Uncertainty by torque sensor calibration [Nm]
Wcal
=
Relative calibration uncertainty (related to nominal torque) [%]
kcal
=
Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1)
upara
=
Uncertainty by parasitic loads [Nm]
wpara
=
senspara * ipara
Relative influence of forces and bending torques caused by misalignment
senspara
=
Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 %
ipara
=
Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below).
=
A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. Figure 1
▼M3 Example of test setup A for Option 1 ▼B
=
B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. Figure 2
▼M3 Example of test setup B for Option 1 ▼B
=
C) 100 % for other setups
▼M3
A test setup for a transmission with integrated differential for front-wheel drive operation consists of a dynamometer on the transmission input side and at least one dynamometer on the transmission output side(s). Torque measuring devices shall be installed on the transmission input- and output- side(s). For test setups with only one dynamometer on the output side, the free rotating end of the transmission with integrated differential shall be rotatably locked to the other end on the output side (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). The graduation of the factor ipara for the maximum influence of parasitic loads for specific torque sensor is equal to the above described cases (A/B/C).
Figure 2A
Example of test setup A for Option 1 for a transmission with integrated differential (e.g. for front-wheel drive operation)
Figure 2B
Example of test setup B for Option 1 for a transmission with integrated differential (e.g. for front-wheel drive operation)
The manufacturer may adapt the test setups A and B based upon good engineering judgement and in agreement with the approval authority, e.g. in the case of practical test setup reasons. In the case of such a deviation, the reason and alternative setup shall be clearly specified in the test report. It is allowed to perform the test without a separate bearing unit on the test rig at the transmission input/output side if the transmission shaft on which the torque is measured is supported by two bearings in the transmission housing which are able to absorb radial and axial forces caused by the gearsets.
Figure 2C
Example where the forces in the transmission are isolated and not isolated from the input:
▼B
| Tl,in | = | Torque loss related to input shaft [Nm] |
|---|---|---|
| Tl,in,min_loss | = | Torque independent loss at minimum hydraulic loss level (minimum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] |
| Tl,in,max_loss | = | Torque independent loss at maximum hydraulic loss level (maximum main pressure, cooling/lubrication flows etc.), measured with free rotating output shaft from testing without load [Nm] |
| floss_corr | = | Loss correction for hydraulic loss level depending on input torque [-] |
| nin | = | Speed at the transmission input shaft (downstream of torque converter, if applicable) [rpm] |
| fT | = | Torque loss coefficient = 1 – ηT |
| Tin | = | Torque at the input shaft [Nm] |
| ηT | = | Torque dependent efficiency (to be calculated); for a direct gear fT = 0,007 (ηT = 0,993) [-] |
| fel_corr | = | Loss correction for electric power loss level depending on input torque [-] |
| Tl,in, el | = | Additional torque loss on input shaft by electric consumers [Nm] |
| Tl,in,min_el | = | Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] |
| Tl,in,max_el | = | Additional torque loss on input shaft by electric consumers corresponding to maximum electric power [Nm] |
| Pel | = | Electric power consumption of electric consumers in transmission measured during transmission loss testing [W] |
| Tmax,in | = | Maximum allowed input torque for any forward gear in the transmission [Nm] |
| floss_tcc | = | Loss correction factor for slipping torque converter (or input side) clutch |
| ntcc | = | Difference in speed between upstream and downstream side of slipping TC lock-up clutch as defined in point 2(16) or slipping input side clutch as defined in 2(20) [rpm] (speed downstream of the slipping clutch is the speed nin at the transmission input shaft) |
| 3.1.1. | The torque dependent losses of a transmission system shall be determined as described in the following: |
In case of multiple parallel and nominally equal power flows, e.g., twin countershafts or several planet gearwheels in a planetary gear set, that can be treated as one power flow in this section.
3.1.1.1.
For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed:
3.1.1.2.
For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm:
external – external gear meshes
:
ηm = 0,986
external – internal gear meshes
:
ηm = 0,993
angle drive gear meshes
:
ηm = 0,97
(Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex)
3.1.1.3.
The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %.
3.1.1.4.
The total torque dependent efficiency η Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n
3.1.1.5.
The torque dependent loss coefficient fTg for the gear g shall be calculated by:
fTg = 1 – η Tg
3.1.1.6.
The torque dependent loss Tl,inTg on the input shaft for gear g shall be calculated by:
Tl,inTg = fTg * Tin
3.1.1.7.
The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by:
where:
ηm,ring
=
Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-]
ηm,sun
=
Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-]
zsun
=
Number of teeth of the sun gearwheel of the range section [-]
zring
=
Number of teeth of the ring gearwheel of the range section [-]
The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4.
3.1.1.8.
For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. In this case, for each indirect gear g, the following steps shall be performed:
3.1.1.9.
Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni ) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction.
3.1.1.10.
For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by:
Nsun–carrier = Nsun
– Ncarrier
Nring–carrier = Nring
– Ncarrier
where:
Nsun
=
Rotational speed of sun gearwheel [rad/s]
Nring
=
Rotational speed of ring gearwheel [rad/s]
Ncarrier
=
Rotational speed of carrier [rad/s]
3.1.1.11.
The loss-producing powers in the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the power P shall be calculated by:
P 1 = N 1 · T 1
P 2 = N 2 · T 2
where:
P
=
Power of gear mesh [W]
N
=
Rotational speed of gearwheel [rad/s]
T
=
Torque of gearwheel [Nm]
For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by:
Pv,sun = Tsun · (Nsun
– Ncarrier ) = Tsun · Nsun/carrier
Pv,ring = Tring · (Nring
– Ncarrier ) = Tring · Nring/carrier
where:
Pv,sun
=
Virtual power of sun gearwheel [W]
Pv,ring
=
Virtual power of ring gearwheel [W]
Tsun
=
Torque of sun gearwheel [Nm]
Tcarrier
=
Torque of carrier [Nm]
Tring
=
Torque of ring gearwheel [Nm]
Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm :
Pi > 0 ⇒ Pi,adj = Pi
Pi < 0 ⇒ Pi,adj = Pi · η mi
where:
Padj
=
Loss-adjusted powers of the gear meshes [W]
ηm
=
Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-]
For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring :
Pv,i ≥ 0 ⇒ Pi,adj = Pv,i
Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring
where:
ηmsun
=
Torque dependent efficiency of sun-to-planet [-]
ηmring
=
Torque dependent efficiency of ring-to-planet [-]
3.1.1.12.
All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss of the transmission system referring to the input power:
Pm,loss = ΣPi,adj
where:
i
=
All gearwheels with a fix rotational axis [-]
Pm,loss
=
Torque dependent gear mesh power loss of the transmission system [W]
3.1.1.13.
The torque dependent loss coefficient for bearings,
fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh
shall be added to receive the total torque dependent loss coefficient fT for the transmission system:
fT = fT,gearmesh + fT,bear
where:
fT
=
Total torque dependent loss coefficient for the transmission system [-]
fT,bear
=
Torque dependent loss coefficient for the bearings [-]
fT,gearmesh
=
Torque dependent loss coefficient for the gear meshes [-]
Pin
=
Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W]
3.1.1.14.
The torque dependent losses on the input shaft for the specific gear shall be calculated by:
Tl,inT = fT * Tin
where:
Tl,inT
=
Torque dependent loss related to input shaft [Nm]
Tin
=
Torque at the input shaft [Nm]
| 3.1.1.1. | For each indirect gear g of common transmissions with a non-split power flow and ordinary, non-planetary gear sets, the following steps shall be performed: |
| 3.1.1.2. | For each active gear mesh, the torque dependent efficiency shall be set to constant values of ηm: |
external – external gear meshes
:
ηm = 0,986
external – internal gear meshes
:
ηm = 0,993
angle drive gear meshes
:
ηm = 0,97
(Angle drive losses may alternatively be determined by separate testing as described in paragraph 6. of this Annex)
| external – external gear meshes | : | ηm |
= 0,986
| external – internal gear meshes | : | ηm |
= 0,993
| angle drive gear meshes | : | ηm |
= 0,97
| 3.1.1.3. | The product of these torque dependent efficiencies in active gear meshes shall be multiplied with a torque dependent bearing efficiency ηb = 99,5 %. |
| 3.1.1.4. | The total torque dependent efficiency η |
Tg for the gear g shall be calculated by: η Tg = η b * η m,1 * η m,2 * […] * η m,n
| 3.1.1.5. | The torque dependent loss coefficient fTg |
for the gear g shall be calculated by:
fTg = 1 – η Tg
| 3.1.1.6. | The torque dependent loss Tl,inTg |
on the input shaft for gear g shall be calculated by:
Tl,inTg = fTg * Tin
3.1.1.7. | The torque dependent efficiency of the planetary range section in low range state for the special case of transmissions consisting of a countershaft-type main section in series with a planetary range section (with non-rotating ring gearwheel and the planet carrier connected to the output shaft) may, alternatively to the procedure described in 3.1.1.8., be calculated by:
where:
ηm,ring
=
Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-]
ηm,sun
=
Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-]
zsun
=
Number of teeth of the sun gearwheel of the range section [-]
zring
=
Number of teeth of the ring gearwheel of the range section [-]
The planetary range section shall be regarded as an additional gear mesh within the countershaft main section, and its torque dependent efficiency ηlowrange shall be included in the determination of the total torque dependent efficiencies ηTg for the low-range gears in the calculation in 3.1.1.4.
| ηm,ring | = | Torque dependent efficiency of the ring-to-planet gear mesh = 99,3 % [-] |
|---|---|---|
| ηm,sun | = | Torque dependent efficiency of the planet-to-sun gear mesh = 98,6 % [-] |
| zsun | = | Number of teeth of the sun gearwheel of the range section [-] |
| zring | = | Number of teeth of the ring gearwheel of the range section [-] |
| 3.1.1.8. | For all other transmission types with more complex split power flows and/or planetary gear sets (e.g. a conventional automatic planetary transmission), the following simplified method shall be used to determine the torque dependent efficiency. The method covers transmission systems composed of ordinary, non-planetary gear sets and/or planetary gear sets of ring-planet-sun type. Alternatively the torque dependent efficiency may be calculated based on VDI Regulation No. 2157. Both calculations shall use the same constant gear mesh efficiency values defined in 3.1.1.2. |
In this case, for each indirect gear g, the following steps shall be performed:
| 3.1.1.9. | Assuming 1 rad/s of input speed and 1 Nm of input torque, a table of speed (Ni |
) and torque (Ti ) values for all gearwheels with a fix rotational axis (sun gearwheels, ring gearwheels and ordinary gearwheels) and planet carriers shall be created. Speed and torque values shall follow the right-hand rule, with engine rotation as the positive direction.
3.1.1.10. | For each planetary gear set, the relative speeds sun-to-carrier and ring-to-carrier shall be calculated by:
Nsun–carrier = Nsun
– Ncarrier
Nring–carrier = Nring
– Ncarrier
where:
Nsun
=
Rotational speed of sun gearwheel [rad/s]
Nring
=
Rotational speed of ring gearwheel [rad/s]
Ncarrier
=
Rotational speed of carrier [rad/s]
| Nsun | = | Rotational speed of sun gearwheel [rad/s] |
|---|---|---|
| Nring | = | Rotational speed of ring gearwheel [rad/s] |
| Ncarrier | = | Rotational speed of carrier [rad/s] |
| 3.1.1.11. | The loss-producing powers in the gear meshes shall be computed in the following way: |
For each ordinary, non-planetary gear set, the power P shall be calculated by:
P 1 = N 1 · T 1
P 2 = N 2 · T 2
where:
P
=
Power of gear mesh [W]
N
=
Rotational speed of gearwheel [rad/s]
T
=
Torque of gearwheel [Nm]
For each planetary gear set, the virtual power of sun Pv,sun and ring gearwheels Pv,ring shall be calculated by:
Pv,sun = Tsun · (Nsun
– Ncarrier ) = Tsun · Nsun/carrier
Pv,ring = Tring · (Nring
– Ncarrier ) = Tring · Nring/carrier
where:
Pv,sun
=
Virtual power of sun gearwheel [W]
Pv,ring
=
Virtual power of ring gearwheel [W]
Tsun
=
Torque of sun gearwheel [Nm]
Tcarrier
=
Torque of carrier [Nm]
Tring
=
Torque of ring gearwheel [Nm]
Negative virtual power results shall indicate power leaving the gear set, positive virtual power results shall indicate power going into the gear set. The loss-adjusted powers Padj of the gear meshes shall be computed in the following way: For each ordinary, non-planetary gear set, the negative power shall be multiplied by the appropriate torque dependent efficiency ηm :
Pi > 0 ⇒ Pi,adj = Pi
Pi < 0 ⇒ Pi,adj = Pi · η mi
where:
Padj
=
Loss-adjusted powers of the gear meshes [W]
ηm
=
Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-]
For each planetary gear set, the negative virtual power shall be multiplied by the torque-dependent efficiencies of sun-to-planet ηmsun and ring-to-planet ηmring :
Pv,i ≥ 0 ⇒ Pi,adj = Pv,i
Pv,i < 0 ⇒ Pi,adj = Pi · ηmsun · ηmring
where:
ηmsun
=
Torque dependent efficiency of sun-to-planet [-]
ηmring
=
Torque dependent efficiency of ring-to-planet [-]
| P | = | Power of gear mesh [W] |
|---|---|---|
| N | = | Rotational speed of gearwheel [rad/s] |
| T | = | Torque of gearwheel [Nm] |
| Pv,sun | = | Virtual power of sun gearwheel [W] |
| Pv,ring | = | Virtual power of ring gearwheel [W] |
| Tsun | = | Torque of sun gearwheel [Nm] |
| Tcarrier | = | Torque of carrier [Nm] |
| Tring | = | Torque of ring gearwheel [Nm] |
| Padj | = | Loss-adjusted powers of the gear meshes [W] |
| ηm | = | Torque dependent efficiency (appropriate to gear mesh; see 3.1.1.2.) [-] |
| ηmsun | = | Torque dependent efficiency of sun-to-planet [-] |
| ηmring | = | Torque dependent efficiency of ring-to-planet [-] |
| 3.1.1.12. | All loss-adjusted power values shall be added up to the torque dependent gear mesh power loss Pm,loss |
of the transmission system referring to the input power:
Pm,loss = ΣPi,adj
where:
i
=
All gearwheels with a fix rotational axis [-]
Pm,loss
=
Torque dependent gear mesh power loss of the transmission system [W]
| i | = | All gearwheels with a fix rotational axis [-] |
|---|---|---|
| Pm,loss | = | Torque dependent gear mesh power loss of the transmission system [W] |
| 3.1.1.13. | The torque dependent loss coefficient for bearings, |
fT,bear = 1 – η bear = 1 – 0,995 = 0,005 and the torque dependent loss coefficient for the gear mesh
shall be added to receive the total torque dependent loss coefficient fT for the transmission system:
fT = fT,gearmesh + fT,bear
where:
fT
=
Total torque dependent loss coefficient for the transmission system [-]
fT,bear
=
Torque dependent loss coefficient for the bearings [-]
fT,gearmesh
=
Torque dependent loss coefficient for the gear meshes [-]
Pin
=
Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W]
| fT | = | Total torque dependent loss coefficient for the transmission system [-] |
|---|---|---|
| fT,bear | = | Torque dependent loss coefficient for the bearings [-] |
| fT,gearmesh | = | Torque dependent loss coefficient for the gear meshes [-] |
| Pin | = | Fixed input power of the transmission; Pin = (1 Nm * 1 rad/s) [W] |
| 3.1.1.14. | The torque dependent losses on the input shaft for the specific gear shall be calculated by: |
Tl,inT = fT * Tin
where:
Tl,inT
=
Torque dependent loss related to input shaft [Nm]
Tin
=
Torque at the input shaft [Nm]
| Tl,inT | = | Torque dependent loss related to input shaft [Nm] |
|---|---|---|
| Tin | = | Torque at the input shaft [Nm] |
| 3.1.2. | The torque independent losses shall be measured in accordance with the procedure described in the following. |
3.1.2.1. General requirements
The transmission used for the measurements shall be in accordance with the drawing specifications for series production transmissions and shall be new. Modifications to the transmission to meet the testing requirements of this Annex, e.g. for the inclusion of measurement sensors or adaption of an external oil conditioning system are permitted. The tolerance limits in this paragraph refer to measurement values without sensor uncertainty.
▼M1
Total tested time per transmission individual and gear shall not exceed 5 times the actual testing time per gear (allowing re-testing of transmission if needed due to measuring or rig error).
▼B
The same transmission individual may be used for a maximum of 10 different tests, e.g. for tests of transmission torque losses for variants with and without retarder (with different temperature requirements) or with different oils. If the same transmission individual is used for tests of different oils, the recommended factory fill oil shall be tested first. It is not permitted to run a certain test multiple times to choose a test series with the lowest results. Upon request of the approval authority the applicant for a certificate shall specify and prove the conformity with the requirements defined in this Annex. 3.1.2.2. Differential measurements
To subtract influences caused by the test rig setup (e.g. bearings, clutches) from the measured torque losses, differential measurements are permitted to determine these parasitic torques.
►M3
The measurements shall be performed at the same speed points and same test rig bearing temperature(s) ± 3 K used for the testing. ◄ The torque sensor measurement uncertainty shall be below 0,3 Nm. 3.1.2.3. Run-in
On request of the applicant a run-in procedure may be applied to the transmission. The following provisions shall apply for a run-in procedure.
3.1.2.3.1.
The procedure shall not exceed 30 hours per gear and 100 hours in total.
3.1.2.3.2.
The application of the input torque shall be limited to 100 % of maximum input torque.
3.1.2.3.3.
The maximum input speed shall be limited by the specified maximum speed for the transmission.
3.1.2.3.4.
The speed and torque profile for the run-in procedure shall be specified by the manufacturer.
3.1.2.3.5.
The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority.
3.1.2.3.6.
The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure.
3.1.2.4. Pre-conditioning
3.1.2.4.1.
Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed.
▼M3
3.1.2.4.2.
The pre-conditioning shall be performed without applied torque to the non driven shaft.
▼B
3.1.2.4.3.
The maximum input speed shall be limited by the specified maximum speed for the transmission.
3.1.2.4.4.
The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed
►M3
100 ◄ minutes.
3.1.2.4.5.
The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures.
3.1.2.5. Test conditions
3.1.2.5.1. Ambient temperature
The ambient temperature during the test shall be in a range of 25 °C ± 10 K. The ambient temperature shall be measured 1 m laterally from the transmission. The ambient temperature limit shall not apply for the run-in procedure. 3.1.2.5.2. Oil temperature
Except for the oil, no external heating is allowed. During measurement (except stabilization) the following temperature limits shall apply: For SMT/AMT/DCT transmissions, the drain plug oil temperature shall not exceed 83 °C when measuring without retarder and 87 °C with retarder mounted to the transmission. If measurements of a transmission without retarder are to be combined with separate measurements of a retarder, the lower temperature limit shall apply to compensate for the retarder drive mechanism and step-up gear and for the clutch in case of a disengageable retarder. For torque converter planetary transmissions and for transmissions having more than two friction clutches, the drain plug oil temperature shall not exceed 93 °C without retarder and 97 °C with retarder. To apply the above defined increased temperature limits for testing with retarder, the retarder shall be integrated in the transmission or have an integrated cooling or oil system with the transmission. During the run-in, the same oil temperature specifications as for regular testing shall apply. Exceptional oil temperature peaks up to 110 °C are allowed for the following conditions:
(1)
during run-in procedure up to maximum of 10 % of the applied run-in time,
(2)
during stabilization time.
The oil temperature shall be measured at the drain plug or in the oil sump. 3.1.2.5.3. Oil quality
New, recommended first fill oil for the European market shall be used in the test. The same oil fill may be used for run-in and torque measurement. 3.1.2.5.4. Oil viscosity
If multiple oils are recommended for first fill, they are considered to be equal if the oils have a kinematic viscosity within 10 % of each other at the same temperature (within the specified tolerance band for KV100). Any oil with lower viscosity than the oil used in the test shall be considered to result in lower losses for the tests performed within this option. Any additional first fill oil must fall either in the 10 % tolerance band or have lower viscosity than the oil in the test to be covered by the same certificate. 3.1.2.5.5. Oil level and conditioning
The oil level shall meet the nominal specifications for the transmission. If an external oil conditioning system is used, the oil inside the transmission shall be kept to the specified volume that corresponds to the specified oil level. To guarantee that the external oil conditioning system is not influencing the test, one test point shall be measured with the conditioning system both on and off. The deviation between the two measurements of the torque loss (= input torque) shall be less than 5 %. The test point is specified as follows:
(1)
gear = highest indirect gear,
▼M3
(2)
input speed = minimum of 60 % of the maximum input speed, not higher than 80 % of the maximum input speed,
▼B
(3)
temperatures as specified under 3.1.2.5.
For transmissions with hydraulic pressure control or a smart lubrication system, the measurement of torque independent losses shall be performed with two different settings: first with the transmission system pressure set to at least the minimum value for conditions with engaged gear and a second time with the maximum possible hydraulic pressure (see 3.1.6.3.1).
| 3.1.2.3.1. | The procedure shall not exceed 30 hours per gear and 100 hours in total. |
|---|---|
| 3.1.2.3.2. | The application of the input torque shall be limited to 100 % of maximum input torque. |
| 3.1.2.3.3. | The maximum input speed shall be limited by the specified maximum speed for the transmission. |
| 3.1.2.3.4. | The speed and torque profile for the run-in procedure shall be specified by the manufacturer. |
| 3.1.2.3.5. | The run-in procedure shall be documented by the manufacturer with regard to run-time, speed, torque and oil temperature and reported to the Approval authority. |
| 3.1.2.3.6. | The requirements for the ambient temperature (3.1.2.5.1.), measurement accuracy (3.1.4.), test set-up (3.1.8.) and installation angle (3.1.3.2) shall not apply for the run-in procedure. |
| 3.1.2.4.1. | Pre-conditioning of the transmission and the test rig equipment to achieve correct and stable temperatures before the run-in and testing procedures is allowed. |
| 3.1.2.4.2. | The pre-conditioning shall be performed without applied torque to the non driven shaft. |
| 3.1.2.4.3. | The maximum input speed shall be limited by the specified maximum speed for the transmission. |
| 3.1.2.4.4. | The maximum combined time for the pre-conditioning shall not exceed 50 hours in total for one transmission. Since the complete testing of a transmission may be divided into multiple test sequences (e.g. each gear tested with a separate sequence), the pre-conditioning may be split into several sequences. Each of the single pre-conditioning sequences shall not exceed |
►M3
100 ◄ minutes.
| 3.1.2.4.5. | The pre-conditioning time shall not be accounted to the time span allocated for the run-in or test procedures. |
| 3.1.3. | Installation |
▼M3
3.1.3.1.
The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft(s) shall rotate freely. In the case of a transmission with an integrated differential, e.g. for front-wheel drive operation, the output ends shall be allowed to be rotatably locked into each other (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement).
▼B
3.1.3.2.
The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°.
3.1.3.3.
The internal oil pump shall be included in the transmission.
3.1.3.4.
If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test.
3.1.3.5.
Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in
►M3
Annex IX ◄ to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off.
3.1.3.6.
Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test.
3.1.3.7.
The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8.
| 3.1.3.1. | The electric machine and the torque sensor shall be mounted to the input side of the transmission. The output shaft(s) shall rotate freely. In the case of a transmission with an integrated differential, e.g. for front-wheel drive operation, the output ends shall be allowed to be rotatably locked into each other (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). |
|---|---|
| 3.1.3.2. | The installation of the transmission shall be done with an angle of inclination as for installation in the vehicle according to the homologation drawing ± 1° or at 0° ± 1°. |
| 3.1.3.3. | The internal oil pump shall be included in the transmission. |
| 3.1.3.4. | If an oil cooler is either optional or required with the transmission, the oil cooler may be excluded in the test or any oil cooler may be used in the test. |
| 3.1.3.5. | Transmission testing can be done with or without power take-off drive mechanism and/or power take-off. For establishing the power losses of power take-offs and /or power take-off drive mechanism, the values in |
►M3
Annex IX ◄ to this regulation are applied. These values assume that the transmission is tested without power take-off drive mechanism and /or power take-off.
| 3.1.3.6. | Measuring the transmission may be performed with or without single dry clutch (with one or two plates) installed. Clutches of any other type shall be installed during the test. |
|---|---|
| 3.1.3.7. | The individual influence of parasitic loads shall be calculated for each specific test rig setup and torque sensor as described in 3.1.8. |
| 3.1.4. | Measurement equipmentThe calibration laboratory facilities shall comply with the requirements of either |
►M3
IATF ◄ 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national (international) standards. 3.1.4.1. Torque
The torque sensor measurement uncertainty shall be below 0,3 Nm. The use of torque sensors with higher measurement uncertainties is allowed if the part of the uncertainty exceeding 0,3 Nm can be calculated and is added to the measured torque loss as described in 3.1.8. Measurement uncertainty. 3.1.4.2. Speed
The uncertainty of the speed sensors shall not exceed ± 1 rpm. 3.1.4.3. Temperature
The uncertainty of the temperature sensors for the measurement of the ambient temperature shall not exceed ± 1,5 K. The uncertainty of the temperature sensors for the measurement of the oil temperature shall not exceed ± 1,5 K. 3.1.4.4. Pressure
The uncertainty of the pressure sensors shall not exceed 1 % of the maximum measured pressure. 3.1.4.5. Voltage
The uncertainty of the voltmeter shall not exceed 1 % of the maximum measured voltage. 3.1.4.6. Electric current
The uncertainty of the amperemeter shall not exceed 1 % of the maximum measured current.
3.1.5. | Measurement signals and data recordingAt least the following signals shall be recorded during the measurement:
(1)
Input torques [Nm]
(2)
Input rotational speeds [rpm]
(3)
Ambient temperature [°C]
(4)
Oil temperature [°C]
If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded:
(5)
Oil pressure [kPa]
If the transmission is equipped with transmission electric auxiliary, additionally to be recorded:
(6)
Voltage of transmission electric auxiliary [V]
(7)
Current of transmission electric auxiliary [A]
For differential measurements for the compensation of influences caused by the test rig setup, additionally shall be recorded:
(8)
Test rig bearing temperature [°C]
The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to reduce measurement errors.
3.1.6. | Test procedure3.1.6.1. Zero torque signal compensation:
The zero-signal of the torque sensor(s) shall be measured. For the measurement the sensor(s) shall be installed in the test rig. The drivetrain of the test rig (input & output) shall be free of load. The measured signal deviation from zero shall be compensated.
▼M3
3.1.6.2. The torque loss shall be measured for the following speed points (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 4 000 rpm and multiples of 10 of these values up to the maximum speed per gear in accordance with the specifications of the transmission or the last speed point before the defined maximum speed. It is permitted to measure additional intermediate speed points.
The speed ramp (time for the change between two speed points) shall not exceed 20 seconds.
▼B
3.1.6.3. Measurement sequence:
3.1.6.3.1.
If the transmission is equipped with smart lubrication systems and/or transmission electric auxiliaries, the measurement shall be conducted with two measurement settings of of these systems: A first measurement sequence (3.1.6.3.2. to 3.1.6.3.4.) shall be performed with the lowest power consumption by hydraulical and electrical systems when operated in the vehicle (low loss level). The second measurement sequence shall be performed with the systems set to work with the highest possible power consumption when operated in the vehicle (high loss level).
3.1.6.3.2.
The measurements shall be performed beginning with the lowest up to the highest speed.
3.1.6.3.3.
►M3
For each speed point a minimum of 5-second stabilisation time within the temperature limits defined in 3.1.2.5 is required. ◄ If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds. Oil and ambient temperatures shall be recorded during the stabilization.
▼M3
3.1.6.3.4.
After the stabilisation time, the torque loss should be constant at the actual measured speed point over time. If so, the measurement signals listed in 3.1.5. shall be recorded for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.1.6.3.5.
Each measurement shall be performed two times per measurement setting.
| 3.1.7. | Measurement validation |
▼M3
3.1.7.1.
The arithmetic mean values shall be calculated for each of the measurements of torque, speed, (if applicable) voltage and current. The measurements to be performed for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.1.7.2.
The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series.
3.1.7.3.
The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed:
▼M3
Tloss = T1,in(nin, Tin,gear)
▼B
Pel = I * U
It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.).
3.1.7.4.
The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values).
3.1.7.5.
The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken.
3.1.7.6.
If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear.
3.1.7.7.
The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken.
3.1.7.8.
If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear.
| 3.1.7.1. | The arithmetic mean values shall be calculated for each of the measurements of torque, speed, (if applicable) voltage and current. The measurements to be performed for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result. |
|---|---|
| 3.1.7.2. | The averaged speed deviation shall be below ± 5 rpm of the speed set point for each measured point for the complete torque loss series. |
| 3.1.7.3. | The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed: |
▼M3
Tloss = T1,in(nin, Tin,gear)
▼B
Pel = I * U
It is allowed to subtract influences caused by the test rig setup from the torque losses (3.1.2.2.).
| 3.1.7.4. | The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). |
|---|---|
| 3.1.7.5. | The deviation between the averaged torque losses of the two measurement points for each setting shall be below ± 5 % of the average or ± 1 Nm, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. |
| 3.1.7.6. | If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. |
| 3.1.7.7. | The deviation between the averaged electric power consumption (voltage * current) values of the two measurements for each measurement setting shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. |
| 3.1.7.8. | If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. |
| 3.1.8. | Measurement uncertaintyThe part of the calculated total uncertainty UT,loss |
exceeding 0,3 Nm shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 0,3 Nm, then Tloss,rep = Tloss .
Tloss,rep = Tloss + MAX (0, (UT,loss
– 0,3 Nm)) The total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters:
(1)
Temperature effect
(2)
Parasitic loads
(3)
Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability)
The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’).
wpara = senspara * ipara
where:
Tloss
=
Measured torque loss (uncorrected) [Nm]
Tloss,rep
=
Reported torque loss (after uncertainty correction) [Nm]
UT,loss
=
Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm]
UT,in
=
Uncertainty of input torque loss measurement [Nm]
uTKC
=
Uncertainty by temperature influence on current torque signal [Nm]
wtkc
=
Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%]
uTK0
=
Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm]
wtk0
=
Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%]
Kref
=
Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K]
ΔK
=
Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used.
Tc
=
Current/measured torque value at torque sensor [Nm]
Tn
=
Nominal torque value of torque sensor [Nm]
ucal
=
Uncertainty by torque sensor calibration [Nm]
Wcal
=
Relative calibration uncertainty (related to nominal torque) [%]
kcal
=
Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1)
upara
=
Uncertainty by parasitic loads [Nm]
wpara
=
senspara * ipara
Relative influence of forces and bending torques caused by misalignment
senspara
=
Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 %
ipara
=
Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below).
=
A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. Figure 1
▼M3 Example of test setup A for Option 1 ▼B
=
B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. Figure 2
▼M3 Example of test setup B for Option 1 ▼B
=
C) 100 % for other setups
▼M3
A test setup for a transmission with integrated differential for front-wheel drive operation consists of a dynamometer on the transmission input side and at least one dynamometer on the transmission output side(s). Torque measuring devices shall be installed on the transmission input- and output- side(s). For test setups with only one dynamometer on the output side, the free rotating end of the transmission with integrated differential shall be rotatably locked to the other end on the output side (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). The graduation of the factor ipara for the maximum influence of parasitic loads for specific torque sensor is equal to the above described cases (A/B/C).
Figure 2A
Example of test setup A for Option 1 for a transmission with integrated differential (e.g. for front-wheel drive operation)
Figure 2B
Example of test setup B for Option 1 for a transmission with integrated differential (e.g. for front-wheel drive operation)
The manufacturer may adapt the test setups A and B based upon good engineering judgement and in agreement with the approval authority, e.g. in the case of practical test setup reasons. In the case of such a deviation, the reason and alternative setup shall be clearly specified in the test report. It is allowed to perform the test without a separate bearing unit on the test rig at the transmission input/output side if the transmission shaft on which the torque is measured is supported by two bearings in the transmission housing which are able to absorb radial and axial forces caused by the gearsets.
Figure 2C
Example where the forces in the transmission are isolated and not isolated from the input:
▼B
| Tloss | = | Measured torque loss (uncorrected) [Nm] |
|---|---|---|
| Tloss,rep | = | Reported torque loss (after uncertainty correction) [Nm] |
| UT,loss | = | Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] |
| UT,in | = | Uncertainty of input torque loss measurement [Nm] |
| uTKC | = | Uncertainty by temperature influence on current torque signal [Nm] |
| wtkc | = | Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] |
| uTK0 | = | Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] |
| wtk0 | = | Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] |
| Kref | = | Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] |
| ΔK | = | Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. |
| Tc | = | Current/measured torque value at torque sensor [Nm] |
| Tn | = | Nominal torque value of torque sensor [Nm] |
| ucal | = | Uncertainty by torque sensor calibration [Nm] |
| Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] |
| kcal | = | Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) |
| upara | = | Uncertainty by parasitic loads [Nm] |
| wpara | = | senspara * ipara |
Relative influence of forces and bending torques caused by misalignment
| senspara | = | Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % |
|---|---|---|
| ipara | = | Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). |
| = | A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 1. |
Figure 1
▼M3 Example of test setup A for Option 1 ▼B
| = | B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 2. |
Figure 2
▼M3 Example of test setup B for Option 1 ▼B
| = | C) 100 % for other setups |
| 3.2. | Option 2: Measurement of the torque independent losses, measurement of the torque loss at maximum torque and interpolation of the torque dependent losses based on a linear modelOption 2 describes the determination of the torque loss by a combination of measurements and linear interpolation. Measurements shall be performed for the torque independent losses of the transmission and for one load point of the torque dependent losses (maximum input torque). Based on the torque losses at no load and at maximum input torque, the torque losses for the input torques in between shall be calculated with the torque loss coefficient fTlimo |
. The torque loss Tl,in on the input shaft of the transmission shall be calculated by
▼M3
T
l,in (n
in ,T
in ,gear) = T
l,in,min_loss + f
Tlino × T
in + T
l,in,min_el + f
el_corr × T
in + f
loss
tcc
× T
in
▼B
The torque loss coefficient based on the linear model fTlimo shall be calculated by
where:
Tl,in
=
Torque loss related to input shaft [Nm]
Tl,in,min_loss
=
Drag torque loss at transmission input, measured with free rotating output shaft from testing without load [Nm]
nin
=
Speed at the input shaft [rpm]
fTlimo
=
Torque loss coefficient based on linear model [-]
Tin
=
Torque at the input shaft [Nm]
Tin,maxT
=
Maximum tested torque at the input shaft (normally 100 % input torque, refer to 3.2.5.2. and 3.4.4.) [Nm]
Tl,maxT
=
Torque loss related to input shaft with Tin = Tin,maxT
fel_corr
=
Loss correction for electric power loss level depending on input torque [-]
Tl,in,el
=
Additional torque loss on input shaft by electric consumers [Nm]
Tl,in,min_el
=
Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm]
▼M3
The correction factor for the torque dependent electric torque losses fel_corr , the torque loss at the input shaft of the transmission caused by the power consumption of transmission electric auxiliary Tl,in,el and the loss correction factor floss_tcc for slipping TC lock-up clutch as defined in point 2(16) or slipping input side clutch as defined in 2(20) shall be calculated as described in point 3.1.
▼B
3.2.1.
The torque losses shall be measured in accordance with the procedure described in the following. 3.2.1.1. General requirements:
As specified for Option 1 in 3.1.2.1. 3.2.1.2. Differential measurements:
As specified for Option 1 in 3.1.2.2. 3.2.1.3. Run-in
As specified for Option 1 in 3.1.2.3. 3.2.1.4. Pre-conditioning
As specified for Option 3 in 3.3.2.1. 3.2.1.5. Test conditions
3.2.1.5.1. Ambient temperature
As specified for Option 1 in 3.1.2.5.1. 3.2.1.5.2. Oil temperature
As specified for Option 1 in 3.1.2.5.2. 3.2.1.5.3. Oil quality / Oil viscosity
As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.2.1.5.4. Oil level and conditioning
As specified for Option 3 in 3.3.3.4.
3.2.2.
InstallationAs specified for Option 1 in 3.1.3. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.4. for the measurement of the torque dependent losses.
3.2.3.
Measurement equipmentAs specified for Option 1 in 3.1.4. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.5. for the measurement of the torque dependent losses.
3.2.4.
Measurement signals and data recordingAs specified for Option 1 in 3.1.5 for the measurement of the torque independent losses. As specified for Option 3 in 3.3.7 for the measurement of the torque dependent losses.
3.2.5.
Test procedureThe torque loss map to be applied to the simulation tool contains the torque loss values of a transmission depending on rotational input speed and input torque. To determine the torque loss map for a transmission, the basic torque loss map data shall be measured and calculated as specified in this paragraph. The torque loss results shall be complemented in accordance with 3.4 and formatted in accordance with Appendix 12 for the further processing by the simulation tool.
3.2.5.1.
The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers.
3.2.5.2.
Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply.
3.2.6.
Measurement validationAs specified for Option 3 in 3.3.8.
3.2.7.
Measurement uncertaintyAs specified for Option 1 in 3.1.8. for the measurement of the torque independent losses. As specified for Option 3 in 3.3.9. for the measurement of the torque dependent loss.
| Tl,in | = | Torque loss related to input shaft [Nm] |
|---|---|---|
| Tl,in,min_loss | = | Drag torque loss at transmission input, measured with free rotating output shaft from testing without load [Nm] |
| nin | = | Speed at the input shaft [rpm] |
| fTlimo | = | Torque loss coefficient based on linear model [-] |
| Tin | = | Torque at the input shaft [Nm] |
| Tin,maxT | = | Maximum tested torque at the input shaft (normally 100 % input torque, refer to 3.2.5.2. and 3.4.4.) [Nm] |
| Tl,maxT | = | Torque loss related to input shaft with Tin = Tin,maxT |
| fel_corr | = | Loss correction for electric power loss level depending on input torque [-] |
| Tl,in,el | = | Additional torque loss on input shaft by electric consumers [Nm] |
| Tl,in,min_el | = | Additional torque loss on input shaft by electric consumers corresponding to minimum electric power [Nm] |
| 3.2.1. | The torque losses shall be measured in accordance with the procedure described in the following. |
3.2.1.1. General requirements:
As specified for Option 1 in 3.1.2.1. 3.2.1.2. Differential measurements:
As specified for Option 1 in 3.1.2.2. 3.2.1.3. Run-in
As specified for Option 1 in 3.1.2.3. 3.2.1.4. Pre-conditioning
As specified for Option 3 in 3.3.2.1. 3.2.1.5. Test conditions
3.2.1.5.1. Ambient temperature
As specified for Option 1 in 3.1.2.5.1. 3.2.1.5.2. Oil temperature
As specified for Option 1 in 3.1.2.5.2. 3.2.1.5.3. Oil quality / Oil viscosity
As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.2.1.5.4. Oil level and conditioning
As specified for Option 3 in 3.3.3.4.
| 3.2.2. | InstallationAs specified for Option 1 in 3.1.3. for the measurement of the torque independent losses. |
As specified for Option 3 in 3.3.4. for the measurement of the torque dependent losses.
| 3.2.3. | Measurement equipmentAs specified for Option 1 in 3.1.4. for the measurement of the torque independent losses. |
As specified for Option 3 in 3.3.5. for the measurement of the torque dependent losses.
| 3.2.4. | Measurement signals and data recordingAs specified for Option 1 in 3.1.5 for the measurement of the torque independent losses. |
As specified for Option 3 in 3.3.7 for the measurement of the torque dependent losses.
| 3.2.5. | Test procedureThe torque loss map to be applied to the simulation tool contains the torque loss values of a transmission depending on rotational input speed and input torque. |
To determine the torque loss map for a transmission, the basic torque loss map data shall be measured and calculated as specified in this paragraph. The torque loss results shall be complemented in accordance with 3.4 and formatted in accordance with Appendix 12 for the further processing by the simulation tool.
3.2.5.1.
The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers.
3.2.5.2.
Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply.
| 3.2.5.1. | The torque independent losses shall be determined by the procedure described in 3.1.1. for the torque independent losses for Option 1 only for the low loss level setting of electric and hydraulic consumers. |
| 3.2.5.2. | Determine the torque dependent losses for each of the gears using the procedure described for Option 3 in 3.3.6., diverging in the applicable torque range: |
Torque range: The torque losses for each gear shall be measured at 100 % of the maximum transmission input torque per gear. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply.
| 3.2.6. | Measurement validationAs specified for Option 3 in 3.3.8. |
| 3.2.7. | Measurement uncertaintyAs specified for Option 1 in 3.1.8. for the measurement of the torque independent losses. |
As specified for Option 3 in 3.3.9. for the measurement of the torque dependent loss.
| 3.3. | Option 3: Measurement of the total torque loss.Option 3 describes the determination of the torque loss by full measurement of the torque dependent losses including the torque independent losses of the transmission. |
3.3.1. General requirements
As specified for Option 1 in 3.1.2.1. 3.3.1.1 Differential measurements:
As specified for Option 1 in 3.1.2.2. 3.3.2. Run-in
As specified for Option 1 in 3.1.2.3. 3.3.2.1 Pre-conditioning
As specified for Option 1 in 3.1.2.4. with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or target torque on the output shaft set to zero. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. or The requirements as specified in 3.1.2.4. shall apply, with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or the torque on the output shaft being within +/- 50 Nm. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. or, if the test rig includes a (master friction) clutch at the input shaft: The requirements as specified in 3.1.2.4. shall apply, with an exception for the following: The pre-conditioning shall be performed on the direct drive gear without applied torque to the output shaft or without applied torque to the input shaft. If the transmission is not equipped with a direct drive gear, the gear with the ratio closest to 1:1 shall be used. The transmission would then be driven from the output side. Those proposals could also be combined. 3.3.3. Test conditions
3.3.3.1. Ambient temperature
As specified for Option 1 in 3.1.2.5.1. 3.3.3.2. Oil temperature
As specified for Option 1 in 3.1.2.5.2. 3.3.3.3. Oil quality / Oil viscosity
As specified for Option 1 in 3.1.2.5.3 and 3.1.2.5.4. 3.3.3.4. Oil level and conditioning
The requirements as specified in 3.1.2.5.5. shall apply, diverging in the following: The test point for the external oil conditioning system is specified as follows:
(1)
highest indirect gear,
▼M3
(2)
input speed = minimum of 60 %, not higher than 80 % of the maximum input speed,
▼B
(3)
input torque = maximum input torque for the highest indirect gear
3.3.4. Installation
The test rig shall be driven by electric machines (input and output).
▼M3
Torque sensors shall be installed at the input and output side(s) of the transmission.
▼B
Other requirements as specified in 3.1.3. shall apply. 3.3.5. Measurement equipment
For the measurement of the torque independent losses, the measurement equipment requirements as specified for Option 1 in 3.1.4. shall apply. For the measurement of the torque dependent losses, the following requirements shall apply: The torque sensor measurement uncertainty shall be below 5 % of the measured torque loss or 1 Nm (whichever value is larger). The use of torque sensors with higher measurement uncertainties is allowed if the parts of the uncertainty exceeding 5 % or 1 Nm can be calculated and the smaller of those parts is added to the measured torque loss. The torque measurement uncertainty shall be calculated and included as described under 3.3.9. Other measurement equipment requirements as specified for Option 1 in 3.1.4. shall apply. 3.3.6. Test procedure
3.3.6.1. Zero torque signal compensation:
As specified in 3.1.6.1.
▼M3
3.3.6.2. Speed range
The torque loss shall be measured for the following speed points (speed of the input shaft): 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 4 000 rpm and multiples of 10 of these values up to the maximum speed per gear according to the specifications of the transmission or the last speed point before the defined maximum speed. It is permitted to measure additional intermediate speed points. The speed ramp (time for the change between two speed points) shall not exceed 20 seconds. 3.3.6.3. Torque range
For each speed point the torque loss shall be measured for the following input torques: 0 (free rotating output shaft), 200, 400, 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 3 500 , 4 000 , […] Nm up to the maximum input torque per gear in accordance with the specifications of the transmission or the last torque point before the defined maximum torque and / or the last torque point before the output torque of 10 kNm. It is permitted to measure additional intermediate torque points. If the torque range is too small, additional torque points are required, so that at least 5 equally spaced torque points shall be measured. The intermediate torque points may be adjusted to the nearest multiple of 50 Nm. In the case the output torque exceeds 10 kNm (for a theoretical loss free transmission) or the input power exceeds the specified maximum input power, point 3.4.4. shall apply. The torque ramp (time for the change between two torque points) shall not exceed 15 seconds (180 seconds for option 2). To cover the complete torque range of a transmission in the above defined map, different torque sensors with limited measurement ranges may be used on the input/output side. Therefore the measurement may be divided into sections using the same set of torque sensors. The overall torque loss map shall be composed of these measurement sections.
▼B
3.3.6.4. Measurement sequence
3.3.6.4.1.
The measurements shall be performed beginning with the lowest up to the highest speed.
▼M3
3.3.6.4.2.
The input torque shall be varied according to the above defined torque points from the lowest to the highest torque which is covered by the current torque sensors for each speed point.
▼B
3.3.6.4.3.
►M3
For each speed and torque point a minimum of 5-second stabilisation time within the temperature limits defined in 3.3.3. is required. ◄ If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds (maximum 180 seconds for option 2). Oil and ambient temperatures shall be recorded during the stabilization.
▼M3
3.3.6.4.3.1.
After the stabilisation time, the torque loss should be constant at the actual measured speed point over time. If so, the measurement signals listed in 3.3.7. shall be recorded for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.3.6.4.4.
The measurement set shall be performed two times in total. For that purpose, sequenced repetition of sections using the same set of torque sensors is allowed.
3.3.7. Measurement signals and data recording
At least the following signals shall be recorded during the measurement:
(1)
Input and output torques [Nm]
(2)
Input and output rotational speeds [rpm]
(3)
Ambient temperature [°C]
(4)
Oil temperature [°C]
If the transmission is equipped with a shift and/or clutch system that is controlled by hydraulic pressure or with a mechanically driven smart lubrication system, additionally to be recorded:
(5)
Oil pressure [kPa]
If the transmission is equipped with transmission electric auxiliary, additionally to be recorded:
(6)
Voltage of transmission electric auxiliary [V]
(7)
Current of transmission electric auxiliary [A]
For differential measurements for compensation of influences by test rig setup, additionally to be recorded:
(8)
Test rig bearing temperature [°C]
The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to avoid measurement errors. 3.3.8. Measurement validation
▼M3
3.3.8.1.
The arithmetic mean values of torque, speed, if applicable voltage and current for the measurement for a minimum of 5 seconds but for no longer than 15 seconds shall be calculated for each of the two measurements. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
3.3.8.2.
The measured and averaged speed at the input shaft shall be below ± 5 rpm of the speed set point for each measured operating point for the complete torque loss series.
►M1
The measured and averaged torque at the input shaft shall be below ± 5 Nm or ±
►M3
1,0 % ◄ of the torque set point whichever value is larger for each measured operating point for the complete torque loss series. ◄
▼M3
3.3.8.3.
The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed:
In the case of a transmission with integrated differential and a dynamometer on each output shaft, the total mechanical torque loss (Tloss) shall be calculated by:
The correction factor for the loss correction floss_tcc for slipping TC lock-up clutch or slipping input side clutch in accordance with the definitions (16) and (20) shall be calculated as described in point 3.1. It is allowed to subtract influences caused by the test rig setup from the torque losses (in accordance with section 3.1.2.2.).
▼B
3.3.8.4.
The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values).
3.3.8.5.
The deviation between the averaged torque losses of the two measurement sets shall be below ± 5 % of the average or ± 1 Nm (whichever value is larger). The arithmetic average of the two averaged torque loss values shall be taken. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear.
3.3.8.6.
The deviation between the averaged electric power consumption (voltage*current) values of the two measurement sets shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken.
3.3.8.7.
If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear.
3.3.9. Measurement uncertainty
The part of the calculated total uncertainty UT,loss exceeding 5 % of Tloss or 1 Nm (ΔUT,loss ), whichever value of ΔUT,loss is smaller, shall be added to Tloss for the reported torque loss Tloss,rep . If UT,loss is smaller than 5 % of Tloss or 1 Nm, then Tloss,rep = Tloss .
Tloss,rep = Tloss + MAX (0, ΔUT,loss )
ΔUT,loss = MIN ((UT,loss
– 5 % * Tloss ), (UT,loss
– 1 Nm)) For each measurement set, the total uncertainty UT,loss of the torque loss shall be calculated based on the following parameters:
(1)
Temperature effect
(2)
Parasitic loads
(3)
Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability)
The total uncertainty of the torque loss (UT,loss ) is based on the uncertainties of the sensors at 95 % confidence level. The calculation shall be done as the square root of the sum of squares (‘Gaussian law of error propagation’).
wpara = senspara * ipara
where:
Tloss
=
Measured torque loss (uncorrected) [Nm]
Tloss,rep
=
Reported torque loss (after uncertainty correction) [Nm]
UT,loss
=
Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm]
uT,in/out
=
Uncertainty of input/output torque loss measurement separately for input and output torque sensor[Nm]
igear
=
Gear ratio [-]
uTKC
=
Uncertainty by temperature influence on current torque signal [Nm]
wtkc
=
Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%]
uTK0
=
Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm]
wtk0
=
Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%]
Kref
=
Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K]
ΔK
=
Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used.
Tc
=
Current/measured torque value at torque sensor [Nm]
Tn
=
Nominal torque value of torque sensor [Nm]
ucal
=
Uncertainty by torque sensor calibration [Nm]
Wcal
=
Relative calibration uncertainty (related to nominal torque) [%]
kcal
=
calibration advancement factor (if declared by sensor manufacturer, otherwise = 1)
upara
=
Uncertainty by parasitic loads [Nm]
wpara
=
senspara * ipara
Relative influence of forces and bending torques caused by misalignment [%]
senspara
=
Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 %
ipara
=
Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below).
=
A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 3. Figure 3
▼M3 Example of test setup A for Option 3 ▼B
=
B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 4. Figure 4
▼M3 Example of test setup B for Option 3 ▼B
=
C) 100 % for other setups
▼M3
A test set-up for the transmission with integrated differential for front-wheel drive operation consists of a dynamometer on the transmission input side and at least one dynamometer on the transmission output side(s). Torque measuring devices shall be installed on the transmission input and output side(s). For test setups with only one dynamometer on the output side, the free rotating end of the transmission with integrated differential shall be rotatably locked to the other end on the output side (e.g. by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). The graduation of the factor ipara for the maximum influence of parasitic loads for the specific torque sensors is equal to the cases described above (A/B/C).
Figure 5
Example of test setup A for a transmission with integrated differential (e.g. for front-wheel drive operation)
Figure 6
Example of test setup B for a transmission with integrated differential (e.g. for front-wheel drive operation)
In the case of a dynamometer on each output shaft, the total uncertainty of the torque loss (UT,loss ) shall be calculated by:
The manufacturer may adapt the test setups A and B based upon good engineering judgement and in agreement with the approval authority, e.g. in the case of practical test setup reasons. In the case of such a deviation, the reason and alternative setup shall be clearly specified in the test report. It is allowed to perform the test without a separate bearing unit on the test rig at the transmission input/output side, if the transmission shaft on which the torque is measured is supported by two bearings in the transmission housing which are able to absorb radial and axial forces caused by the gearsets (see figure 2C in 3.1.8.).
▼B
| 3.3.6.4.1. | The measurements shall be performed beginning with the lowest up to the highest speed. |
|---|---|
| 3.3.6.4.2. | The input torque shall be varied according to the above defined torque points from the lowest to the highest torque which is covered by the current torque sensors for each speed point. |
| 3.3.6.4.3. | ►M3 |
For each speed and torque point a minimum of 5-second stabilisation time within the temperature limits defined in 3.3.3. is required. ◄ If needed, the stabilization time may be extended by the manufacturer to maximum 60 seconds (maximum 180 seconds for option 2). Oil and ambient temperatures shall be recorded during the stabilization.
▼M3
3.3.6.4.3.1.
After the stabilisation time, the torque loss should be constant at the actual measured speed point over time. If so, the measurement signals listed in 3.3.7. shall be recorded for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result.
▼B
| 3.3.6.4.3.1. | After the stabilisation time, the torque loss should be constant at the actual measured speed point over time. If so, the measurement signals listed in 3.3.7. shall be recorded for a minimum of 5 seconds but for no longer than 15 seconds. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result. |
|---|---|
| 3.3.6.4.4. | The measurement set shall be performed two times in total. For that purpose, sequenced repetition of sections using the same set of torque sensors is allowed. |
| 3.3.8.1. | The arithmetic mean values of torque, speed, if applicable voltage and current for the measurement for a minimum of 5 seconds but for no longer than 15 seconds shall be calculated for each of the two measurements. If the torque loss is not constant at the actual measured speed point over time, e.g. by intended periodic variation of the torque losses caused by active or passive means of control, the manufacturer shall use the testing time required to get a reproducible and representative result. |
| 3.3.8.2. | The measured and averaged speed at the input shaft shall be below ± 5 rpm of the speed set point for each measured operating point for the complete torque loss series. |
►M1
The measured and averaged torque at the input shaft shall be below ± 5 Nm or ±
►M3
1,0 % ◄ of the torque set point whichever value is larger for each measured operating point for the complete torque loss series. ◄
3.3.8.3. | The mechanical torque losses and (if applicable) electrical power consumption shall be calculated for each of the measurements as followed:
In the case of a transmission with integrated differential and a dynamometer on each output shaft, the total mechanical torque loss (Tloss) shall be calculated by:
The correction factor for the loss correction floss_tcc for slipping TC lock-up clutch or slipping input side clutch in accordance with the definitions (16) and (20) shall be calculated as described in point 3.1. It is allowed to subtract influences caused by the test rig setup from the torque losses (in accordance with section 3.1.2.2.).
| 3.3.8.4. | The mechanical torque losses and (if applicable) electrical power consumption from the two sets shall be averaged (arithmetic mean values). | |
|---|---|---|
| 3.3.8.5. | The deviation between the averaged torque losses of the two measurement sets shall be below ± 5 % of the average or ± 1 Nm (whichever value is larger). The arithmetic average of the two averaged torque loss values shall be taken. If the deviation is higher, the largest averaged torque loss value shall be taken or the test shall be repeated for the gear. | |
| 3.3.8.6. | The deviation between the averaged electric power consumption (voltage*current) values of the two measurement sets shall be below ± 10 % of the average or ± 5 W, whichever value is larger. Then, the arithmetic average of the two averaged power values shall be taken. | |
| 3.3.8.7. | If the deviation is higher, the set of averaged voltage and current values giving the largest averaged power consumption shall be taken, or the test shall be repeated for the gear. | |
| Tloss | = | Measured torque loss (uncorrected) [Nm] |
| Tloss,rep | = | Reported torque loss (after uncertainty correction) [Nm] |
| UT,loss | = | Total expanded uncertainty of torque loss measurement at 95 % confidence level [Nm] |
| uT,in/out | = | Uncertainty of input/output torque loss measurement separately for input and output torque sensor[Nm] |
| igear | = | Gear ratio [-] |
| uTKC | = | Uncertainty by temperature influence on current torque signal [Nm] |
| wtkc | = | Temperature influence on current torque signal per Kref, declared by sensor manufacturer [%] |
| uTK0 | = | Uncertainty by temperature influence on zero torque signal (related to nominal torque) [Nm] |
| wtk0 | = | Temperature influence on zero torque signal per Kref (related to nominal torque), declared by sensor manufacturer [%] |
| Kref | = | Reference temperature span for uTKC and uTK0, wtk0 and wtkc, declared by sensor manufacturer [K] |
| ΔK | = | Difference in sensor temperature between calibration and measurement [K]. If the sensor temperature cannot be measured, a default value of ΔK = 15 K shall be used. |
| Tc | = | Current/measured torque value at torque sensor [Nm] |
| Tn | = | Nominal torque value of torque sensor [Nm] |
| ucal | = | Uncertainty by torque sensor calibration [Nm] |
| Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] |
| kcal | = | calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) |
| upara | = | Uncertainty by parasitic loads [Nm] |
| wpara | = | senspara * ipara |
Relative influence of forces and bending torques caused by misalignment [%]
| senspara | = | Maximum influence of parasitic loads for specific torque sensor declared by sensor manufacturer [%]; if no specific value for parasitic loads is declared by the sensor manufacturer, the value shall be set to 1,0 % |
|---|---|---|
| ipara | = | Maximum influence of parasitic loads for specific torque sensor depending on test setup (A/B/C, as defined below). |
| = | A) 10 % in case of bearings isolating the parasitic forces in front of and behind the sensor and a flexible coupling (or cardan shaft) installed functionally next to the sensor (downstream or upstream); furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 3. |
Figure 3
▼M3 Example of test setup A for Option 3 ▼B
| = | B) 50 % in case of bearings isolating the parasitic forces in front of and behind the sensor and no flexible coupling installed functionally next to the sensor; furthermore, these bearings can be integrated in a driving/braking machine (e.g. electric machine) and/or in the transmission as long as the forces in the machine and/or transmission are isolated from the sensor. See figure 4. |
Figure 4
▼M3 Example of test setup B for Option 3 ▼B
| = | C) 100 % for other setups |
| 3.4. | Complement of input files for the simulation tool |
►M3
For each gear a torque loss map covering the defined input speed and input torque points shall be determined with one of the specified testing options or standard torque loss values. ◄ For the input file for the simulation tool, this basic torque loss map shall be complemented as described in the following:
3.4.1.
►M3
In the cases the highest tested input speed was the last speed point below the defined maximum permissible transmission speed, an extrapolation of the torque loss shall be applied up to the maximum speed with linear regression based on the two last measured speed points. ◄
3.4.2.
►M3
In the cases the highest tested input torque was the last torque point below the defined maximum permissible transmission torque, an extrapolation of the torque loss shall be applied up to the maximum torque with linear regression based on the two last measured torque points for the corresponding speed point. ◄ In order to handle engine torque tolerances, etc., the simulation tool will, if required, perform an extrapolation of the torque loss for input torques up to 10 % above said defined maximum permissible transmission torque.
3.4.3.
In the case of extrapolation of the torque loss values for maximum input speed and maximum input torque at the same time, the torque loss for the combined point of highest speed and highest torque shall be calculated with two-dimensional linear extrapolation.
3.4.4.
If the maximum output torque exceeds 10 kNm (for a theoretical loss free transmission), and/or for all speed and torque points with input power higher than the specified maximum input power, the manufacturer may choose to take the torque loss values for all torques higher than 10 kNm, and/or for all speed and torque points with input power higher than the specified maximum input power, respectively, from one of:
(1)
Calculated fallback values (Appendix 8)
(2)
Option 1
(3)
Option 2 or 3 in combination with a torque sensor for higher output torques (if required)
For cases (i) and (ii) in Option 2, the torque losses at load shall be measured at the input torque that corresponds to output torque 10 kNm and/or the specified maximum input power.
▼M3
3.4.5.
For speeds below the defined minimum speed and the additional input speed step of 0 rpm, the reported torque losses determined for the minimum speed point shall be copied.
▼B
3.4.6.
To cover the range of negative input torques during vehicle coasting conditions, the torque loss values for positive input torques shall be copied for the related negative input torques.
3.4.7.
Upon agreement of an approval authority, the torque losses for the input speeds below 1 000 rpm may be replaced by the torque losses at 1 000 rpm when the measurement is technically not possible.
▼M3
3.4.8.
If the measurement of speed points is technically not possible (e.g. due to natural frequency), the manufacturer may, in agreement with the approval authority, calculate the torque losses by interpolation or extrapolation (limited to max. 1 speed point per gear).
▼B
3.4.9.
The torque loss map data shall be formatted and saved as specified in Appendix 12 to this Annex.
3.4.1. | ►M3
In the cases the highest tested input speed was the last speed point below the defined maximum permissible transmission speed, an extrapolation of the torque loss shall be applied up to the maximum speed with linear regression based on the two last measured speed points. ◄
3.4.2. | ►M3
In the cases the highest tested input torque was the last torque point below the defined maximum permissible transmission torque, an extrapolation of the torque loss shall be applied up to the maximum torque with linear regression based on the two last measured torque points for the corresponding speed point. ◄ In order to handle engine torque tolerances, etc., the simulation tool will, if required, perform an extrapolation of the torque loss for input torques up to 10 % above said defined maximum permissible transmission torque.
| 3.4.3. | In the case of extrapolation of the torque loss values for maximum input speed and maximum input torque at the same time, the torque loss for the combined point of highest speed and highest torque shall be calculated with two-dimensional linear extrapolation. |
| 3.4.4. | If the maximum output torque exceeds 10 kNm (for a theoretical loss free transmission), and/or for all speed and torque points with input power higher than the specified maximum input power, the manufacturer may choose to take the torque loss values for all torques higher than 10 kNm, and/or for all speed and torque points with input power higher than the specified maximum input power, respectively, from one of: |
(1)
Calculated fallback values (Appendix 8)
(2)
Option 1
(3)
Option 2 or 3 in combination with a torque sensor for higher output torques (if required)
For cases (i) and (ii) in Option 2, the torque losses at load shall be measured at the input torque that corresponds to output torque 10 kNm and/or the specified maximum input power.
| 3.4.5. | For speeds below the defined minimum speed and the additional input speed step of 0 rpm, the reported torque losses determined for the minimum speed point shall be copied. |
|---|---|
| 3.4.6. | To cover the range of negative input torques during vehicle coasting conditions, the torque loss values for positive input torques shall be copied for the related negative input torques. |
| 3.4.7. | Upon agreement of an approval authority, the torque losses for the input speeds below 1 000 rpm may be replaced by the torque losses at 1 000 rpm when the measurement is technically not possible. |
| 3.4.8. | If the measurement of speed points is technically not possible (e.g. due to natural frequency), the manufacturer may, in agreement with the approval authority, calculate the torque losses by interpolation or extrapolation (limited to max. 1 speed point per gear). |
| 3.4.9. | The torque loss map data shall be formatted and saved as specified in Appendix 12 to this Annex. |
4. Testing procedure for torque converter (TC)
Option A: measurement at constant input speed;
Changed in this versionOption B: measurement at constant input torque in accordance with SAE J643. The manufacturer may choose option A or B for case S and case P arrangements. For the input to the simulation tool, the torque ratio μ and reference torque Tpum of the torque converter shall be measured for a range of v ≤ 0,95 (= vehicle propulsion mode). In the case of use of standard values, the data on torque converter characteristics provided to the simulation tool shall only cover the range of v ≤ 0,95 (or the adjusted speed ratio). The simulation tool automatically adds the generic values for overrun conditions. Table 1 Default values for v ≥ 1,00
v | μ | Tpum
1000
| 1,000 | 1,0000 | 0,00 |
|---|---|---|
| 1,100 | 0,9999 | – 40,34 |
| 1,222 | 0,9998 | – 80,34 |
| 1,375 | 0,9997 | – 136,11 |
| 1,571 | 0,9996 | – 216,52 |
| 1,833 | 0,9995 | – 335,19 |
| 2,200 | 0,9994 | – 528,77 |
| 2,500 | 0,9993 | – 721,00 |
| 3,000 | 0,9992 | – 1 122,00 |
| 3,500 | 0,9991 | – 1 648,00 |
| 4,000 | 0,9990 | – 2 326,00 |
| 4,500 | 0,9989 | – 3 182,00 |
| 5,000 | 0,9988 | – 4 242,00 |
4.1. Option A: Measured torque converter characteristics at constant speed
4.1.1. General requirements
4.1.2. Oil temperature
4.1.3. Oil flow rate and pressure
4.1.4. Oil quality/Oil viscosity
4.1.5. Installation
4.1.6. Measurement equipment
4.1.6.1. Torque
4.1.6.2. Speed
4.1.6.3. Temperature
4.1.7. Test procedure
4.1.7.1. Zero torque signal compensation
4.1.7.2. Measurement sequence
4.1.8. Measurement signals and data recording
Input (pump) torque Tc,pum [Nm]
Changed in this versionOutput (turbine) torque Tc,tur [Nm]
Changed in this versionInput rotational (pump) speed npum [rpm]
Changed in this versionOutput rotational (turbine) speed ntur [rpm]
Changed in this versionTC input oil temperature KTCin [°C] The sampling and recording rate shall be 100 Hz or higher. A low pass filter shall be applied to avoid measurement errors.
Changed in this version4.1.9. Measurement validation
4.1.10. Measurement uncertainty
Calibration error (incl. sensitivity tolerance, linearity, hysteresis and repeatability) The uncertainty UT,pum/tur of the torque measurement is based on the uncertainties of the sensors at 95 % confidence level. where:
| Tc,pum/tur | = | Current / measured torque value at input/output torque sensor (uncorrected) [Nm] |
|---|---|---|
| Tpum | = | Input (pump) torque (after uncertainty correction) [Nm] |
| UT,pum/tur | = | Uncertainty of input / output torque measurement at 95 % confidence level separately for input and output torque sensor[Nm] |
| Tn | = | Nominal torque value of torque sensor [Nm] |
| ucal | = | Uncertainty by torque sensor calibration [Nm] |
| Wcal | = | Relative calibration uncertainty (related to nominal torque) [%] |
| kcal | = | Calibration advancement factor (if declared by sensor manufacturer, otherwise = 1) |
4.1.11. Calculation of TC characteristics
4.2. Option B: Measurement at constant input torque (in accordance with SAE J643)
4.2.1. General requirements
4.2.2. Oil temperature
4.2.3. Oil flow rate and pressure
4.2.4. Oil quality
4.2.5. Installation
4.2.6. Measurement equipment
4.2.7. Test procedure
4.2.7.1. Zero torque signal compensation
4.1.7.2. Measurement sequence
4.2.8. Measurement signals and data recording
4.2.9. Measurement validation
4.2.10. Measurement uncertainty
4.2.11. Calculation of TC characteristics
5. ►M3 Testing procedure for other torque transferring components (OTTC) ◄
5.1. Methods for establishing retarder drag losses
Measurement on the retarder as a stand-alone unit
Changed in this versionMeasurement in combination with the transmission
Changed in this version5.1.1. General requirements
5.1.2. Run-in
5.1.3. Test conditions
5.1.3.1. Ambient temperature
5.1.3.2. Ambient pressure
5.1.3.3. Oil or water temperature
5.1.3.4. Oil or water quality
5.1.3.5. Oil viscosity
5.1.3.6. Oil or water level
5.1.4. Installation
5.1.5. Measurement equipment
5.1.6. Test procedure
5.1.6.1. Zero torque signal compensation:
5.1.6.2. Measurement sequence
5.1.6.2.1. Measurement on the retarder as stand-alone unit
5.1.6.2.2. Measurement in combination with the transmission
5.1.6.2.2. The torque loss shall be measured at the operating speeds as indicated for the related transmission testing.
5.1.7. Measurement signals and data recording
5.1.8. Measurement validation
5.2. Complement of input files for the simulation tool
6. Testing procedure for additional drivetrain components (ADC) / drivetrain component with a single speed ratio (e.g. angle drive)
Methods for establishing losses of a drivetrain component with a single speed ratio The losses of a drivetrain component with a single speed ratio shall be determined using one of the following cases:
Changed in this versionCase A: Measurement on a separate drivetrain component with a single speed ratio For the torque loss measurement of a drivetrain component with a single speed ratio, the three options as defined for the determination of the transmission losses shall apply:
| Option 1 | : | Measured torque independent losses and calculated torque dependent losses (Transmission test option 1) |
|---|---|---|
| Option 2 | : | Measured torque independent losses and measured torque dependent losses at full load (Transmission test option 2) |
| Option 3 | : | Measurement under full load points (Transmission test option 3) |
The measurement, the validation and the uncertainty calculation of the losses of a drivetrain component with a single speed ratio shall follow the procedure described for the related transmission test option in point 3 diverging in the following requirements: Measurements shall be performed at 200 rpm and 400 rpm (at the input shaft of the drivetrain component with a single speed ratio) and for the following speed points: 600, 900, 1 200 , 1 600 , 2 000 , 2 500 , 3 000 , 4 000 rpm and multiples of 10 of these values up to the maximum speed in accordance with specifications of the drivetrain component with a single speed ratio, or the last speed point before the defined maximum speed. It is permitted to measure additional intermediate speed points. 6.1.1.1 Applicable speed range:
Changed in this versionCase B: Individual measurement of a drivetrain component with a single speed ratio connected to a transmission Where the drivetrain component with a single speed ratio is tested in combination with a transmission, the testing shall follow one of the defined options for transmission testing:
| Option 1 | : | Measured torque independent losses and calculated torque dependent losses (Transmission test option 1) |
|---|---|---|
| Option 2 | : | Measured torque independent losses and measured torque dependent losses at full load (Transmission test option 2) |
| Option 3 | : | Measurement under full load points (Transmission test option 3) |
6.1.2.1 The manufacturer may separate the losses of a drivetrain component with a single speed ratio from the total transmission losses by testing in the order as described below:
Changed in this versionThe torque loss for the complete transmission including drivetrain component with a single speed ratio shall be measured as defined for the applicable transmission testing option = Tl,in,withad
Changed in this versionThe drivetrain component with a single speed ratio and related parts shall be replaced with parts required for the equivalent transmission variant without drivetrain component with a single speed ratio. The measurement of point (1) shall be repeated. = Tl,in,withoutad
Changed in this versionThe torque loss for the drivetrain component system with a single speed ratio shall be determined by calculating the differences between the two test data sets = Tl,in,adsys = max(0, Tl,in,withad – Tl,in,withoutad)
Changed in this versionComplement of input files for the simulation tool
Changed in this versionTorque losses for speeds below the above defined minimum speed and additionally at input speed point of 0 rpm shall be set equal to the torque loss at the minimum speed.
Changed in this versionIn the cases the highest tested input speed of the drivetrain component with a single speed ratio was the last speed point below the defined maximum permissible speed of the drivetrain component with a single speed ratio, an extrapolation of the torque loss shall be applied up to the maximum speed with linear regression based on the two last measured speed points.
Changed in this versionTo calculate the torque loss data for the input shaft of the transmission the drivetrain component with a single speed ratio is to be combined with, linear interpolation and extrapolation shall be used.
Changed in this version7. Conformity of the certified CO2 emissions and fuel consumption related properties
8. Production conformity testing
8.1 Conformity testing of transmissions
Appendix 1
MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF A TRANSMISSON / TORQUE CONVERTER / OTHER TORQUE TRANSFERRING COMPONENT/ ADDITIONAL DRIVELINE COMPONENT ( 15 ) FAMILY
SECTION I
SECTION II
1. Additional information (where applicable): see Addendum
1.1. Option used for the determination of the torque losses
Appendix 2
Transmission information document
0. GENERAL
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) TRANSMISSION AND THE TRANSMISSION TYPES WITHIN A TRANSMISSION FAMILY
1.0 SPECIFIC TRANSMISSION/TRANSMISSION FAMILY INFORMATION
LIST OF ATTACHMENTS
Attachment 1 to Transmission information document
Information on test conditions (if applicable)
Appendix 3
Hydrodynamic torque converter (TC) information document
0. GENERAL
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) TC AND THE TC TYPES WITHIN A TC FAMILY
1.0 SPECIFIC TORQUE CONVERTER/TORQUE CONVERTER FAMILY INFORMATION
LIST OF ATTACHMENTS
Attachment 1 to Torque Converter information document
Information on test conditions (if applicable)
1. Method of measurement
Appendix 4
Other torque transferring components (OTTC) information document
0. GENERAL
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) OTTC AND THE OTTC TYPES WITHIN AN OTTC FAMILY
1.0 SPECIFIC OTTC INFORMATION
LIST OF ATTACHMENTS
Attachment 1 to OTTC information document
Information on test conditions (if applicable)
1. Method of measurement
Appendix 5
Additional driveline components (ADC) information document
0. GENERAL
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) ADC AND THE ADC TYPES WITHIN AN ADC FAMILY
1.0 SPECIFIC ADC/ANGLE DRIVE INFORMATION
LIST OF ATTACHMENTS
Attachment 1 to ADC information document
Information on test conditions (if applicable)
1. Method of measurement
Appendix 6
Family Concept
1. General
1.1 Special cases
Appendix 7
Markings and numbering
1. Markings
2. Numbering
Appendix 8
Standard torque loss values - Transmission
Appendix 9
Generic model – torque converter
Figure 1
Generic torque capacity
Figure 2
Generic torque ratio
The model requires the following definitions for the calculation of the generic torque ratio:
Changed in this versionLinear interpolation between the calculated specific points shall be used.
Changed in this versionAppendix 10 — Standard torque loss values – other torque transferring components
Calculated standard torque loss values for other torque transferring components: For primary hydrodynamic retarders (oil or water) with included vehicle launch functionality, the retarder drag torque shall be calculated by For other hydrodynamic retarders (oil or water), the retarder drag torque shall be calculated by For magnetic retarders (permanent or electro-magnetic), the retarder drag torque shall be calculated by: where:
| Tretarder | = | Retarder drag loss [Nm] |
|---|---|---|
| nretarder | = | Retarder rotor speed [rpm] (see point 5.1 of this Annex) |
| istep-up | = | Step-up ratio = retarder rotor speed / drive component speed (see point 5.1 of this Annex) |
Appendix 11
Standard torque loss values – geared angle drive or drivetrain component with a single speed ratio
Appendix 12
Input parameters for the simulation tool
Introduction
Definitions
‘Parameter ID’:Unique identifier as used in ‘Simulation tool’ for a specific input parameter or set of input data
(2) | ‘Type’:Data type of the parameter
string …
sequence of characters in ISO8859-1 encoding
token …
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date …
date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer …
value with an integral data type, no leading zeros, e.g. ‘1800’
double, X …
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’ |
| integer … | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’ |
‘Unit’ …physical unit of the parameter
Changed in this versionSet of input parameters
ANNEX VII — Calculation of the standard torque loss
VERIFYING AXLE DATA
1. Introduction
2. Definitions
‘Single reduction axle (SR)’ means a driven axle with only one gear reduction, typically a bevel gear set with or without hypoid offset.
Changed in this version‘Single portal axle (SP)’ means an axle, that has typically a vertical offset between the rotating axis of the crown gear and the rotating axis of the wheel due to the demand of a higher ground clearance or a lowered floor to allow a low floor concept for inner city buses.
►M3
Typically, the first reduction is a bevel gear set, the second one a spur gear set (or helical gear set) with vertical offset close to the wheels. ◄
Changed in this version‘Hub reduction axle (HR)’ means a driven axle with two gear reductions. The first is typically a bevel gear set with or without hypoid offset. The other is a planetary gear set, what is typically placed in the area of the wheel hubs.
Changed in this version‘Single reduction tandem axle (SRT)’ means a driven axle that is basically similar to a single driven axle, but has also the purpose to transfer torque from the input flange over an output flange to a further axle. The torque can be transferred with a spur gear set close at the input flange to generate a vertical offset for the output flange. Another possibility is to use a second pinion at the bevel gear set, what takes off torque at the crown wheel.
Changed in this version‘Hub reduction tandem axle (HRT)’ means a hub reduction axle, what has the possibility to transfer torque to the rear as described under single reduction tandem axle (SRT).
Changed in this version‘Axle housing’ means the housing parts that are needed for structural capability as well as for carrying the driveline parts, bearings and sealings of the axle.
Changed in this version‘Pinion’ means a part of a bevel gear set which usually consists of two gears. The pinion is the driving gear which is connected with the input flange. In case of a SRT / HRT, a second pinion can be installed to take off torque from the crown wheel.
Changed in this version‘Crown wheel’ means a part of a bevel gear set which usually consists of two gears. The crown wheel is the driven gear and is connected with the differential cage.
Changed in this version‘Hub reduction’ means the planetary gear set that is installed commonly outside the planetary bearing at hub reduction axles. The gear set consists of three different gears. The sun, the planetary gears and the ring gear. The sun is in the centre, the planetary gears are rotating around the sun and are mounted to the planetary carrier that is fixed to the hub. Typically, the number of planetary gears is between three and five. The ring gear is not rotating and fixed to the axle beam.
Changed in this version‘Planetary gear wheels’ means the gears that rotate around the sun within the ring gear of a planetary gear set. They are assembled with bearings on a planetary carrier, what is joined to a hub.
Changed in this version‘Oil type viscosity grade’ means a viscosity grade as defined by SAE J306.
Changed in this version‘Factory fill oil’ means the oil type viscosity grade that is used for the oil fill in the factory and which is intended to stay in the axle for the first service interval.
Changed in this version‘Axle line’ means a group of axles that share the same basic axle-function as defined in the family concept.
Changed in this version‘Axle family’ means a manufacturer's grouping of axles which through their design, as defined in Appendix 4 of this Annex, have similar design characteristics and CO2 and fuel consumption properties.
Changed in this version‘Drag torque’ means the required torque to overcome the inner friction of an axle when the wheel ends are rotating freely with 0 Nm output torque.
Changed in this version‘Mirror inverted axle casing’ means the axle casing is mirrored regarding to the vertical plane.
Changed in this version‘Axle input’ means the side of the axle on which the torque is delivered to the axle.
Changed in this version‘Axle output’ means the side(s) of the axle where the torque is delivered to the wheels.
Changed in this version3. General requirements
3.1 Run-in
4. Testing procedure for axles
4.1 Test conditions
4.1.1 Ambient temperature
4.1.2 Oil temperature
4.1.3 Oil quality
4.1.4 Oil viscosity
4.1.5 Oil level and conditioning
4.2 Test set-up
4.2.1 Axle installation
4.2.2 Installation of torque meters
4.2.3 Test set-up ‘Type A’
Figure 1
Example of Test set-up ‘Type A’
4.2.4 Test set-up ‘Type B’
4.3 Test procedure
4.3.1 Measurement equipment
4.3.1.1 Torque measurement
4.3.1.2 Rotational speed
4.3.1.3 Temperatures
4.3.2 Measurement signals and data recording
Input and output torques [Nm]
Changed in this versionInput and/or output rotational speeds [rpm]
Changed in this versionAmbient temperature [°C]
Changed in this versionOil temperature [°C]
Changed in this versionTemperature at the torque sensor
►M3
[°C] (optional) ◄
| 4.3.2.1 | The following minimum sampling frequencies of the sensors shall be applied: |
Torque: 1 kHz Rotational speed: 200 Hz Temperatures: 10 Hz
| 4.3.2.2 | The recording rate of the data used to determine the arithmetic mean values of each grid point shall be 10 Hz or higher. The raw data do not need to be reported. |
Signal filtering may be applied in agreement with the approval authority. Any aliasing effect shall be avoided.
Changed in this version4.3.3 Torque range:
| 4.3.3.1 | The manufacturer may extend the measurement up to 20 kNm output torque by means of linear extrapolation of torque losses or by performing measurements up to 20 kNm output torque with steps of 2 000 Nm. For this additional torque range another torque sensor at the output side with a maximum torque of 20 kNm (2-machine layout) or two 10 kNm sensors (3-machine layout) shall be used. |
If the radius of the smallest tire is reduced (e.g. product development) after completing the measurement of an axle or when the physic boundaries of the test stand are reached (e.g. by product development changes), the missing points may be extrapolated by the manufacturer out of the existing map. The extrapolated points shall not exceed more than 10 % of all points in the map and the penalty for these points is 5 % torque loss to be added on the extrapolated points.
| 4.3.3.2 | Output torque steps to be measured for heavy lorries and heavy buses: |
250 Nm < Tout < 1 000 Nm : 250 Nm steps 1 000 Nm ≤ Tout ≤ 2 000 Nm : 500 Nm steps 2 000 Nm ≤ Tout ≤ 10 000 Nm : 1 000 Nm steps
Tout > 10 000 Nm : 2 000 Nm steps Output torque steps to be measured for medium lorries: 50 Nm < Tout < 200 Nm : 50 Nm steps 200 Nm ≤ Tout ≤ 400 Nm : 100 Nm steps 400 Nm ≤ Tout ≤ 2 000 Nm : 200 Nm steps
Tout > 2 000 Nm : 400 Nm steps
Changed in this version4.3.4 Speed range
4.3.5 Wheel speed steps to be measured
4.4 Measurement of torque loss maps for axles
4.4.1 Testing sequence of the torque loss map
4.4.2 Measurement duration
4.4.3 Averaging of grid points
5. Conformity of the certified CO2 emissions and fuel consumption related properties
6. Production conformity testing
Appendix 1
MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF AN AXLE FAMILY
SECTION I
SECTION II
Appendix 2
Axle information document
0. GENERAL
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) AXLE AND THE AXLE TYPES WITHIN AN AXLE FAMILY
1.0 SPECIFIC AXLE INFORMATION
LIST OF ATTACHMENTS
Appendix 3 — Calculation of the standard torque loss
The standard torque losses for axles are shown in Table 1. The standard table values consist of the sum of a generic constant efficiency value covering the load dependent losses and a generic basic drag torque loss to cover the drag losses at low loads. Tandem axles shall be calculated using a combined efficiency for an axle including drive-thru (SRT, HRT) plus the matching single axle (SR, HR). Table 1 Generic efficiency and drag loss
Basic function | Generic efficiency
| η | Drag torque |
(wheel side)
Td0 = T0 + T1 × igear
| Single reduction axle (SR) | 0,98 | T0 |
= 70 Nm
T1 = 20 Nm
| Single reduction tandem axle (SRT) / single portal axle (SP) | 0,96 | T0 |
= 80 Nm
T1 = 20 Nm
| Hub reduction axle (HR) | 0,97 | T0 |
= 70 Nm
T1 = 20 Nm
| Hub reduction tandem axle (HRT) | 0,95 | T0 |
= 90 Nm
T1 = 20 Nm
| All other axle technologies | 0,90 | T0 |
= 150 Nm
T1 = 50 Nm The basic drag torque (wheel side) Td0 is calculated by Td0 = T0 + T1 × igear using the values from Table 1. The standard torque loss Tloss,std on the input side of the axle is calculated by where:
| Tloss,std | = | Standard torque loss at the input side [Nm] |
|---|---|---|
| Td0 | = | Basis drag torque over the complete speed range [Nm] |
| igear | = | Axle gear ratio [-] |
| η | = | Generic efficiency for load dependent losses [-] |
| Tout | = | torque [Nm] |
The corresponding torque (at input side) of the axle shall be calculated by where:
Tin | = | Input torque [Nm]
Appendix 4
Family Concept
Appendix 5
Markings and numbering
1. Markings
2. Numbering:
Appendix 6
Input parameters for the simulation tool
Introduction
Definitions
‘Parameter ID’:Unique identifier as used in the simulation tool for a specific input parameter or set of input data
| (2) | ‘Type’: |
Data type of the parameter
string …
sequence of characters in ISO8859-1 encoding
token …
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date …
date and time in UTC time in the format: YYYY-MM-DD T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer …
value with an integral data type, no leading zeros, e.g. ‘1800’
double, X …
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format: YYYY-MM-DD |
T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
| integer … | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’ |
‘Unit’ …physical unit of the parameter
Changed in this versionSet of input parameters
ANNEX VIII
VERIFYING AIR DRAG DATA
1. Introduction
2. Definitions
‘Active aero device’ means measures which are activated by a control unit to reduce the air drag of the total vehicle.
Changed in this version‘Aero accessories’ mean optional devices which have the purpose to influence the air flow around the total vehicle.
Changed in this version‘A-pillar’ means the connection by a supporting structure between the cabin roof and the front bulkhead.
Changed in this version‘Body in white geometry’ means the supporting structure incl. the windshield of the cabin.
Changed in this version‘B-pillar’ means the connection by a supporting structure between the cabin floor and the cabin roof in the middle of the cabin.
Changed in this version‘Cab bottom’ means the supporting structure of the cabin floor.
Changed in this version‘Cabin over frame’ means distance from frame to cabin reference point in vertical Z. Distance is measured from top of horizontal frame to cabin reference point in vertical Z.
Changed in this version‘Cabin reference point’ means the reference point (X/Y/Z = 0/0/0) from the CAD coordinate system of the cabin or a clearly defined point of the cabin package e.g. heel point.
Changed in this version‘Cabin width’ means the horizontal distance of the left and right B-pillar of the cabin.
Changed in this version‘Constant speed test’ means measurement procedure to be carried out on a test track in order to determine the air drag.
Changed in this version‘Dataset’ means the data recorded during a single passing of a measurement section.
Changed in this version‘EMS’ means the European Modular System (EMS) in accordance with Council Directive 96/53/EC.
Changed in this version‘Frame height’ means distance of wheel center to top of horizontal frame in Z.
Changed in this version‘Heel point’ means the point which is representing the heel of shoe location on the depressed floor covering, when the bottom of shoe is in contact with the undepressed accelerator pedal and the ankle angle is at 87°. (ISO 20176:2011)
Changed in this version‘Measurement area(s)’ means designated part(s) of the test track consisting of at least one measurement section and a preceded stabilisation section.
Changed in this version‘Measurement section’ means a designated part of the test track which is relevant for data recording and data evaluation.
Changed in this version‘Roof height’ means distance in vertical Z from cabin reference point to highest point of roof w/o sunroof
Changed in this version3. Determination of air drag
3.1. Test track requirements
3.2. Requirements for ambient conditions
Appendix 1
MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF AN AIR DRAG FAMILY
SECTION I
SECTION II
Appendix 2
Air drag information document
0.0. GENERAL
Name and address of manufacturer
Changed in this versionMake (trade name of manufacturer)
Changed in this versionAir drag type (family if applicable)
Changed in this versionCommercial name(s) (if available)
Changed in this versionMeans of identification of type, if marked on the vehicle
Changed in this versionIn the case of components and separate technical units, location and method of affixing of the certification mark
Changed in this versionName(s) and address(es) of assembly plant(s)
Changed in this versionName and address of the manufacturer's representative
Changed in this versionPART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) AIR DRAG AND THE AIR DRAG TYPES WITHIN AN AIR DRAG FAMILY
1.0. SPECIFIC AIR DRAG INFORMATION
VEHICLE
Changed in this versionHDV group according to HDV CO2 scheme
Changed in this versionVehicle model / Commercial Name
Changed in this versionAxle configuration 1.2.2 Technically permissible maximum laden mass
Changed in this versionCabin or model line
Changed in this versionCabin width (max. value in Y direction, for vehicles with a cabin)
Changed in this versionCabin length (max. value in X direction, for vehicles with a cabin)
Changed in this versionRoof height (for vehicles with a cabin)
Changed in this versionWheel base
Changed in this versionHeight cabin over frame (for vehicles with a frame)
Changed in this versionFrame height (for vehicles with a frame)
Changed in this versionAerodynamic accessories or add-ons (e.g. roof spoiler, side extender, side skirts, corner vanes)
Changed in this versionTyre dimensions front axle
Changed in this versionTyre dimensions driven axles(s)
Changed in this versionVehicle width in accordance with item (8) of point 2 of Annex III (for vehicles without a cabin)
Changed in this versionVehicle length in accordance with item (7) of point 2 of Annex III (for vehicles without a cabin)
Changed in this versionHeight of the integrated body in accordance with item (5) of point 2 of Annex III (for vehicles without a cabin)
| 1.3. | Body specifications (according to standard body definition) |
|---|---|
| 1.4. | (Semi-) Trailer specifications (according to (semi-) trailer specification by standard body) |
| 1.5. | Parameter defining the family in accordance with the description of the applicant (parent criteria and deviated family criteria) |
LIST OF ATTACHMENTS
Attachment 1 to Information Document
Information on test conditions (if applicable)
Test track on which tests have been conducted
Changed in this versionTotal vehicle mass during measurement [kg]
Changed in this versionMaximum vehicle height during measurement [m]
Changed in this versionAverage ambient conditions during first low speed test [°C]
Changed in this versionAverage vehicle speed during high speed tests [km/h]
Changed in this versionProduct of drag coefficient (Cd ) by cross sectional area (Acr ) for zero crosswind conditions CdAcr(0) [m2]
Changed in this versionProduct of drag coefficient (Cd ) by cross sectional area (Acr ) for average crosswind conditions during constant speed test CdAcr(β) [m2]
Changed in this versionAverage yaw angle during constant speed test β [°]
Changed in this versionDeclared air drag value Cd·Adeclared [m2]
Changed in this versionVersion number of air drag pre-processing tool
Changed in this versionAppendix 3
Vehicle height requirements for rigid lorries and tractors
Medium rigid lorries, heavy rigid lorries and tractors measured in the constant speed test in accordance with point 3 of this Annex have to meet the vehicle height requirements as shown in Table 2.
Changed in this versionThe vehicle height has to be determined as described in 3.5.3.1, item (vii).
Changed in this versionAny kind of rigid lorries and tractors of vehicle groups not shown in Table 2 are not subject to constant speed testing. Table 2 Vehicle height requirements for medium rigid lorries, heavy rigid lorries and tractors
| Vehicle group | minimum vehicle height [m] | maximum vehicle height [m] |
|---|---|---|
| 51, 53, 55 | 3,20 | 3,50 |
| 1s, 1 | 3,40 | 3,60 |
| 2 | 3,50 | 3,75 |
| 3 | 3,70 | 3,90 |
| 4 | 3,85 | 4,00 |
| 5 | 3,90 | 4,00 |
| 9 | similar values as for rigid lorries with same technically permissible maximum laden mass (group 1, 2, 3 or 4) | |
| 10 | 3,90 | 4,00 |
Appendix 4
Standard body and semitrailer configurations for rigid lorries and tractors
►M3
Medium rigid lorries and heavy rigid lorries which are subject to determination of air drag have to fulfil the requirements on standard bodies as described in this Appendix. Tractors have to fulfil the requirements for standard semitrailers as described in this Appendix. ◄
Changed in this versionThe applicable standard body or semitrailer shall be determined from Table 8. Table 3 Allocation of standard bodies and semitrailer for constant speed testing
| Vehicle groups | Standard body or trailer |
|---|---|
| 51, 53, 55 | B-II |
| 1s, 1 | B1 |
| 2 | B2 |
| 3 | B3 |
| 4 | B4 |
| 5 | ST1 |
| 9 | depending on technically permissible maximum laden mass: |
7,5 – 10 t: B1 > 10 – 12 t: B2 > 12 – 16 t: B3 > 16 t: B5
10 | ST1
Changed in this versionThe standard bodies B-II, B1, B2, B3, B4 and B5 shall be constructed as a hard shell body in dry-out box design. They shall be equipped with two rear doors and without any side doors. The standard bodies shall not be equipped with tail lifts, front spoilers or side fairings for reduction of aerodynamic drag. The specifications of the standard bodies are given in: Mass indications as given in Table 9a to Table 15 are not subject to inspection for air drag testing.
Changed in this versionThe type and chassis requirements for the standard semitrailer ST1 are listed in Table 14. The specifications are given in Table 15.
Changed in this versionAll dimensions and masses without tolerances mentioned explicitly shall be in line with Regulation (EC) No 1230/2012, Annex 1, Appendix 2 (i.e. in the range of ± 3 % of the target value). Table 9 Specifications of standard body ‘B1’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 6 200 | |
| Width | [mm] | 2 550 (– 10) | |
| Height | [mm] | 2 680 (± 10) | box: external height: 2 560 |
longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 50 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 50 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 1 600 | ►M3 |
Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing ◄ Table 9a Specifications of standard body ‘B-II’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 4 500 (± 10) | |
| Width | [mm] | 2 300 (± 10) | |
| Height | [mm] | 2 500 (± 10) | box: |
external height: 2 380 longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 30 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 30 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 800 | Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing |
Table 10 Specifications of standard body ‘B2’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 7 400 | |
| Width | [mm] | 2 550 (– 10) | |
| Height | [mm] | 2 760 (± 10) | box: external height: 2 640 |
longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 50 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 50 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 1 900 | ►M3 |
Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing ◄ Table 11 Specifications of standard body ‘B3’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 7 450 | |
| Width | [mm] | 2 550 (– 10) | legal limit (96/53/EC), |
internal ≥ 2 480
| Height | [mm] | 2 880 (± 10) | box: external height: 2 760 |
longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 50 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 50 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 2 000 | ►M3 |
Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing ◄ Table 12 Specifications of standard body ‘B4’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 7 450 | |
| Width | [mm] | 2 550 (– 10) | |
| Height | [mm] | 2 980 (± 10) | box: external height: 2 860 |
longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 50 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 50 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 2 100 | ►M3 |
Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing ◄ Table 13 Specifications of standard body ‘B5’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Length | [mm] | 7 820 | internal ≥ 7 650 |
| Width | [mm] | 2 550 (– 10) | legal limit (96/53/EC), |
internal ≥ 2 460
| Height | [mm] | 2 980 (± 10) | box: external height: 2 860 |
longitudinal beam: 120
| Corner radius side & roof with front panel | [mm] | 50 - 80 | |
|---|---|---|---|
| Corner radius side with roof panel | [mm] | 50 - 80 | |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Mass | [kg] | 2 200 | ►M3 |
Mass is used as a generic value in the simulation tool and does not need to be verified for air drag testing ◄ Table 14 Type and chassis configuration of standard semitrailer ‘ST1’
| Type of trailer | 3-axle semi-trailer w/o steering axle(s) |
| Chassis configuration | — End to end ladder frame |
— Frame w/o underfloor cover
— 2 stripes at each side as underride protection
— Rear underride protection (UPS)
— Rear lamp holder plate
— w/o pallet box
— Two spare wheels after the 3rd axle
— One toolbox at the end of the body before UPS (left or right side)
— Mud flaps before and behind axle assembly
— Air suspension
— Disc brakes
— Tyre size: 385/65 R 22,5
— 2 back doors
— w/o side door(s)
— w/o tail lift
— w/o front spoiler
— w/o side fairings for aero Table 15 Specifications standard semitrailer ‘ST1’
| Specification | Unit | External dimension | |
|---|---|---|---|
| (tolerance) | Remarks | ||
| Total length | [mm] | 13 685 | |
| Total width (Body width) | [mm] | 2 550 (– 10) | |
| Body height | [mm] | 2 850 (± 10) | max. full height: 4 000 (96/53/EC) |
| Full height, unloaded | [mm] | 4 000 (– 10) | height over the complete length specification for semi-trailer, not relevant for checking of vehicle height during constant speed test |
| Trailer coupling height, unloaded | [mm] | 1 150 | specification for semitrailer, not subject to inspection during constant speed test |
| Wheelbase | [mm] | 7 700 | |
| Axle distance | [mm] | 1 310 | 3-axle assembly, 24t (96/53/EC) |
| Front overhang | [mm] | 1 685 | radius: 2 040 (legal limit, 96/53/EC) |
| Front wall | flat wall with attachments for compressed air and electricity | ||
| Corner front/side panel | [mm] | broken with a strip and edge radii ≤ 5 | secant of a circle with the kingpin as centre and a radius of 2 040 (legal limit, 96/53/EC) |
| Remaining corners | [mm] | broken with radius ≤ 10 | |
| Toolbox dimension vehicle x-axis | [mm] | 655 | Tolerance: ± 10 % of target value |
| Toolbox dimension vehicle y-axis | [mm] | 445 | Tolerance: ± 5 % of target value |
| Toolbox dimension vehicle z-axis | [mm] | 495 | Tolerance: ± 5 % of target value |
| Side underride protection length | [mm] | 3 045 | 2 stripes at each side, acc. ECE- R 73, Amendment 01 (2010), +/– 100 depending on wheelbase |
| Stripe profile | [mm2] | 100 × 30 | ECE- R 73, Amendment 01 (2010) |
| Technical gross vehicle weight | [kg] | 39 000 | legal GVWR: 24 000 (96/53/EC) |
| Vehicle curb weight | [kg] | 7 500 | has not be verified during air drag testing |
| Allowable axle load | [kg] | 24 000 | legal limit (96/53/EC) |
| Technical axle load | [kg] | 27 000 | 3 × 9 000 |
Appendix 5
Air drag family
1. General
2. Special cases
4. Parameter defining the air drag family for medium and heavy lorries
5. Choice of the air drag parent vehicle for medium and heavy lorries
Appendix 6
Conformity of the certified CO2 emissions and fuel consumption related properties
The conformity of the certified CO2 emissions and fuel consumption related properties shall be verified by constant speed tests as laid down in section 3 of the main part of this Annex. For conformity of the certified CO2 emissions and fuel consumption related properties the following additional provisions apply: The ambient temperature of the constant speed test shall be within a range of ± 5 °C to the value from the certification measurement. This criterion is verified based on the average temperature from the first low speed tests as calculated by the air drag pre-processing tool. The high speed test shall be performed in a vehicle speed range within ± 2 km/h to the value from the certification measurement. All conformity of the certified CO2 emissions and fuel consumption related properties tests shall be supervised by the approval authority.
Changed in this versionA vehicle fails the conformity of the certified CO2 emissions and fuel consumption related properties test if the measured Cd Acr (0) value is higher than the Cd · Adeclared value declared for the parent vehicle plus 7,5 % tolerance margin. If a first test fails, up to two additional tests at different days with the same vehicle may be performed.
►M1
Where the measured Cd Acr (0) value of all performed tests is higher than the Cd·Adeclared value declared for the parent vehicle plus 7,5 % tolerance margin, Article 23 of this Regulation shall apply. ◄ For calculation of Cd Acr (0) value the air drag pre-processing tool version of the parent air drag in accordance with Attachment 1 of Appendix 2 to this Annex shall be used.
Changed in this versionThe number of vehicles to be tested for conformity with the certified CO2 emissions and fuel consumption related properties per year of production shall be determined based on Table 17. The table shall be applied separately to medium lorries, heavy lorries and heavy buses. Table 17 Number of vehicles to be tested for conformity with the certified CO2 emissions and fuel consumption related properties per year of production (to be applied separately for medium lorries, heavy lorries and heavy buses)
| Number of CoP tested vehicles | Schedule | Number of CoP relevant vehicles produced the year before |
|---|---|---|
| 0 | — | ≤ 25 |
| 1 | every 3rd year (*1) | 25 < X ≤ 500 |
| 1 | every 2nd year | 500 < X ≤ 5 000 |
| 1 | every year | 5 000 < X ≤ 15 000 |
| 2 | every year | ≤ 25 000 |
| 3 | every year | ≤ 50 000 |
| 4 | every year | ≤ 75 000 |
| 5 | every year | ≤ 100 000 |
| 6 | every year | 100 001 and more |
(*1) The CoP test shall be performed within the first two years For the purpose of establishing the production numbers, only air drag data which fall under the requirements of this Regulation and which did not get standard air drag values according to Appendix 7 of this Annex shall be considered.
Changed in this versionFor the selection of vehicles for conformity of the certified CO2 emissions and fuel consumption related properties testing the following provisions apply: Only vehicles from the production line shall be tested. Only vehicles which fulfil the provisions for constant speed testing as laid down in section 3.3 of the main part of this Annex shall be selected. Tires are considered part of the measurement equipment and can be selected by the manufacturer. Vehicles in families where the air drag value has been determined via transfer from other vehicles according to Appendix 5 point 5 are not subject to conformity of the certified CO2 emissions and fuel consumption related properties testing. Vehicles which use standard values for air drag according to Appendix 8 are not subject to conformity of the certified CO2 emissions and fuel consumption related properties testing. A first vehicle to be tested for conformity with the certified CO2 emissions and fuel consumption related properties shall be selected from the air drag type or air drag family representing the highest production numbers in the corresponding year. Any additional vehicles shall be selected from all air drag families and shall be agreed between the manufacturer and the approval authority based on the air drag families and vehicle groups already tested. If only one test per year or less has to be executed, the vehicle shall always be selected from all air drag families and shall be agreed between the manufacturer and the approval authority.
Changed in this versionAfter a vehicle was selected for conformity of the certified CO2 emissions and fuel consumption related properties the manufacturer has to verify the conformity of the certified CO2 emissions and fuel consumption related properties within a time period of 12 month. The manufacturer may request the approval authority for an extension of that period for up to 6 months if he can prove that the verification was not possible within the required period due to weather conditions.
Changed in this versionAppendix 7
Standard values
Standard values for heavy lorries are defined in accordance with Table 18. Table 18 Standard values for Cd·Adeclared for heavy lorries
| Vehicle group | Standard value Cd·Adeclared |
[m2]
| 1, 1s | 7,1 |
|---|---|
| 2 | 7,2 |
| 3 | 7,4 |
| 4 | 8,4 |
| 5 | 8,7 |
| 9 | 8,5 |
| 10 | 8,8 |
| 11 | 8,5 |
| 12 | 8,8 |
| 16 | 9,0 |
—
Changed in this version—
Changed in this versionStandard values for heavy buses are defined in accordance with Table 21. For vehicle groups for which no measurement of aerodynamic drag is allowed (in accordance with point 7.3. in Appendix 5 of this Annex), standard values are not relevant. Table 21 Standard values for Cd·Adeclared for heavy buses
| Vehicle parameter sub-group | Standard value Cd·Adeclared |
[m2]
| 31a | not relevant |
|---|---|
| 31b1 | not relevant |
| 31b2 | 4,9 |
| 31c | not relevant |
| 31d | not relevant |
| 31e | not relevant |
| 32a | 4,6 |
| 32b | 4,6 |
| 32c | 4,6 |
| 32d | 4,6 |
| 32e | 5,2 |
| 32f | 5,2 |
| 33a | not relevant |
| 33b1 | not relevant |
| 33b2 | 5,0 |
| 33c | not relevant |
| 33d | not relevant |
| 33e | not relevant |
| 34a | 4,7 |
| 34b | 4,7 |
| 34c | 4,7 |
| 34d | 4,7 |
| 34e | 5,3 |
| 34f | 5,3 |
| 35a | not relevant |
| 35b1 | not relevant |
| 35b2 | 5,1 |
| 35c | not relevant |
| 36a | 4,8 |
| 36b | 4,8 |
| 36c | 4,8 |
| 36d | 4,8 |
| 36e | 5,4 |
| 36f | 5,4 |
| 37a | not relevant |
| 37b1 | not relevant |
| 37b2 | 5,1 |
| 37c | not relevant |
| 37d | not relevant |
| 37e | not relevant |
| 38a | 4,8 |
| 38b | 4,8 |
| 38c | 4,8 |
| 38d | 4,8 |
| 38e | 5,4 |
| 38f | 5,4 |
| 39a | not relevant |
| 39b1 | not relevant |
| 39b2 | 5,2 |
| 39c | not relevant |
| 40a | 4,9 |
| 40b | 4,9 |
| 40c | 4,9 |
| 40d | 4,9 |
| 40e | 5,5 |
| 40f | 5,5 |
Standard values for medium lorries are defined in accordance with Table 22. Table 22 Standard values for Cd·Adeclared for medium lorries
| Vehicle group | Standard value Cd·Adeclared |
[m2]
| 53 | 5,8 |
| 54 | 2,5 |
Appendix 8
Markings
1.4.1 Example and dimensions of the certification mark
2 Numbering
Appendix 9
Input parameters for the simulation tool
Introduction
Definitions
‘Parameter ID’:Unique identifier as used in the simulation tool for a specific input parameter or set of input data
| (2) | ‘Type’: |
Data type of the parameter
string …
sequence of characters in ISO8859-1 encoding
token …
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date …
date and time in UTC time in the format: YYYY-MM-DD T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer …
value with an integral data type, no leading zeros, e.g. ‘1800’
double, X …
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format: YYYY-MM-DD |
T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
| integer … | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’ |
‘Unit’ …physical unit of the parameter
Changed in this versionSet of input parameters
ANNEX IX
VERIFYING LORRY AND BUS AUXILIARY DATA
1. Introduction
Engine cooling fan
Changed in this versionSteering system
Changed in this versionElectric system
Changed in this versionPneumatic system
Changed in this versionHeating, ventilation and air conditioning (HVAC) system
Changed in this versionTransmission Power Take Off (PTO) The generic values are integrated in the simulation tool and automatically used based on the relevant input information in accordance with the provisions in this Annex. The related input data formats for the simulation tool are described in Annex III. For a clear reference, the three-digit parameter IDs used in Annex III are also listed in this Annex.’;
Changed in this version2. Definitions
‘crankshaft mounted’ fan means a fan installation where the fan is driven in the prolongation of the crankshaft, often by a flange (engine cooling fan);
Changed in this version‘belt or transmission driven’ fan means a fan that is installed in a position where additional belt, tension system or transmission is needed (engine cooling fan);
Changed in this version‘hydraulic driven’ fan means a fan propelled by hydraulic oil, often installed away from the engine. A hydraulic system with oil system, pump and valves are influencing losses and efficiencies in the system (engine cooling fan);
Changed in this version‘electrically driven’ fan means a fan propelled by an electric motor. The efficiency for complete energy conversion, included in/out from battery, is considered (engine cooling fan);
Changed in this version‘electronically controlled visco clutch’ means a clutch in which a number of sensor inputs together with SW logic are used to electronically actuate the fluid flow in the visco clutch (engine cooling fan);
Changed in this version‘bimetallic controlled visco clutch’ means a clutch in which a bimetallic connection is used to convert a temperature change into mechanical displacement. The mechanical displacement is then working as an actuator for the visco clutch (engine cooling fan);
Changed in this version‘discrete step clutch’ means a mechanical device where the grade of actuation can be made in distinct steps only (not continuous variable) (engine cooling fan);
Changed in this version‘on/off clutch’ means a mechanical clutch which is either fully engaged or fully disengaged (engine cooling fan);
Changed in this version‘variable displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump can be varied while the pump is running (engine cooling fan);
Changed in this version‘constant displacement pump’ means a device that converts mechanical energy to hydraulic fluid energy. The amount of fluid pumped per revolution of the pump cannot be varied while the pump is running (engine cooling fan);
Changed in this version‘electric motor control’ means the use of an electric motor to propel the fan. The electrical machine converts electrical energy into mechanical energy. Power and speed are controlled by conventional technology for electric motors (engine cooling fan);
Changed in this version‘fixed displacement pump (default technology)’ means a pump having an internal limitation of the flow rate (steering system);
Changed in this version‘fixed displacement pump with electronic control’ means a pump using an electronic control of the flow rate (steering system);
Changed in this version‘dual displacement pump’ means a pump with two chambers (with the same or different displacement) mechanical internal limitation of flow rate (steering system); ‘dual displacement pump with electronic control’ means a pump with two chambers (with the same or different displacement) which can be combined or where under specific conditions only one of these is used. The flow rate is electronically controlled by a valve (steering system);
Changed in this version‘variable displacement pump mech. controlled’ means a pump where the displacement is mechanically controlled internally (internal pressure scales) (steering system);
Changed in this version‘variable displacement pump elec. controlled’ means a pump where the displacement is electronically controlled (steering system);
Changed in this version‘electric driven pump’ means a steering system driven by an electric motor with continuously recirculating hydraulic fluid (steering system); ‘full electric steering gear’ means a steering system driven by an electric motor without continuously recirculating hydraulic fluid (steering system);
Changed in this version-
Changed in this version‘air compressor with energy saving system’ or ‘ESS’ means a compressor reducing the power consumption during blow off, e.g. by closing intake side, ESS is controlled by system air pressure (pneumatic system);
Changed in this version‘compressor clutch (visco)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy), minor losses during disengaged state caused by visco clutch (pneumatic system);
Changed in this version‘compressor clutch (mechanically)’ means a disengageable compressor where the clutch is controlled by the system air pressure (no smart strategy) (pneumatic system);
Changed in this version‘air management system with optimal regeneration’ or ‘AMS’ means an electronic air processing unit that combines an electronically controlled air dryer for optimised air regeneration and an air delivery preferred during overrun conditions (requires a clutch or ESS) (pneumatic system).
Changed in this version‘light emitting diode’ or ‘LED’ means semiconductor devices that emit visible light when an electrical current passes through them (electric system);
Changed in this version-
Changed in this version‘power take-off’ or ‘PTO’ means a device on a transmission or an engine to which an optional power consuming device (‘consumer’), e.g., a hydraulic pump, can be connected; a power take-off is usually optional (PTO);
Changed in this version‘power take-off drive mechanism’ means a device in a transmission that allows the installation of a power take-off (PTO); ‘engaged gearwheel’ means a gearwheel which is engaged with running shafts of either the engine or transmission while the PTO clutch (if applicable) is open (PTO);
Changed in this version‘tooth clutch’ means a (manoeuvrable) clutch where torque is transferred mainly by normal forces between mating teeth. A tooth clutch can either be engaged or disengaged. It is operated in load-free conditions only (e.g. at gear shifts in a manual transmission) (PTO);
Changed in this version‘synchroniser’ means a type of tooth clutch where a friction device is used to equalise the speeds of the rotating parts to be engaged (PTO);
Changed in this version‘multi-disc clutch’ means a clutch where several friction linings are arranged in parallel whereby all friction pairs get the same pressing force. Multi-disc clutches are compact and can be engaged and disengaged under load. They may be designed as dry or wet clutches (PTO);
Changed in this version‘sliding wheel’ means a gearwheel used as shift element where the shifting is realised by moving the gearwheel on its shaft into or out of the gear mesh of the mating gear (PTO);
Changed in this version‘discrete step clutch (off + 2 stages)’ means a mechanical device where the grade of actuation can be made in two distinct steps plus off only (not continuous variable) (engine cooling fan);
Changed in this version‘discrete step clutch (off + 3 stages)’ means a mechanical device where the grade of actuation can be made in three distinct steps plus off only (not continuous variable) (engine cooling fan);
Changed in this version‘ratio compressor to engine’ means the forward gear ratio of the speed of the engine to the speed of the air compressor without slip (i = nin/nout) (pneumatic system);
Changed in this version‘air suspension control mechanically’ means an air supension system in which the air suspension control valves are operated mechanically without electronics and software (pneumatic system);
Changed in this version‘air suspension control electronically’ means an air supension system in which a number of sensor inputs together with software logic are used to electronically actuate the air suspension control valves (pneumatic system);
Changed in this version‘pneumatic SCR reagent dosing’ means that compressed air is used for dosing reagent into the exhaust system (pneumatic system);
Changed in this version‘door drive technology pneumatic’ means that the passenger doors of the vehicle are operated with compressed air (pneumatic system);
Changed in this version‘door drive technology electric’ means that the passenger doors of the vehicle are operated with an electric motor or with an electrohydraulic system (pneumatic system);
Changed in this version‘door drive technology mixed’ means that both ‘door drive technology pneumatic’ and ‘door drive technology electric’ are installed in the vehicle (pneumatic system);
Changed in this version‘smart regeneration system’ means a pneumatic system in which the regeneration air demand is optimised with respect to the quantity of dried air that is produced (pneumatic system);
Changed in this version‘smart compression system’ means a pneumatic system in which the air delivery is electronically controlled with preferred air delivery during overrun conditions (pneumatic system);
Changed in this version‘interior lights’ means the lights within the passenger compartment that are installed to fulfil the requirements of paragraph 7.8. (artificial interior lighting) in Annex 3 to UN Regulation No. 107 ( *2 ) (electric system);
Changed in this version‘day running lights’ means the ‘daytime running lamp’ in accordance with paragraph 2.7.25 of UN Regulation No. 48 ( *3 ) (electric system);
Changed in this version‘position lights’ means the ‘side marker lamp’ in accordance with paragraph 2.7.24 of UN Regulation No. 48 (electric system);
Changed in this version‘brake lights’ means the ‘stop lamp’ in accordance with paragraph 2.7.12 of UN Regulation No. 48 (electric system);
Changed in this version‘headlights’ means the ‘passing-beam (dipped-beam) headlamp’ in accordance with paragraph 2.7.10 of UN Regulation No. 48, and the ‘driving-beam (main-beam) headlamp’ in accordance with paragraph 2.7.9 of UN Regulation No. 48 (electric system);
Changed in this version‘alternator’ means an electric machine to charge the battery and to supply electric power to the electrical auxiliary system when the vehicle’s internal combustion engine is running. An alternator can not contribute to propulsion of the vehicle (electric system);
Changed in this version‘smart alternator system’ means a system of one ore more alternators in combination with one or more dedicated REESS which is electronically controlled with preferred generation of electic energy during overrun conditions (electric system);
Changed in this version‘heating, ventilation and air conditioning system’ or HVAC system means a system that can actively heat and/or actively cool down and exchange or replace air to provide improved air qualityfor the passenger and/or the driver compartment (HVAC system);
Changed in this version‘HVAC system configuration’ means a combination of HVAC system components in accordance with Table 13 of this Annex (HVAC system);
Changed in this version‘thermal comfort system for passenger compartment’ means a system that uses fans to circulate air within the vehicle or blows fresh air into the vehicle and the air volume flow can at least be actively cooled or heated. The air is distributed from the roof of the vehicle and in the case of double deckers, in both floors. In the case of open top double deckers, in the lower deck (HVAC system);
Changed in this version‘number of heat pumps for passenger compartment’ means the number of heat pumps that are installed in the vehicle to heat up and/or cool down cabin air or fresh air supplied to the passenger compartment. If a heat pump is used for the passenger and for the driver compartment it is counted for the passenger compartment only (HVAC system). If different heat pumps for heating and cooling are installed, the number of heat pumps shall be defined by the lower number of both separate cases – i.e. the number of heat pumps for cooling and the number of heat pumps for heating shall be considered separately (e.g. in the case of 2 heat pumps for cooling and 1 heat pump for heating: only 1 heat pump shall be considered);
Changed in this version‘air conditioning system for driver compartment’ means that a system is installed in the vehicle that can cool down the cabin air or fresh air supplied to the driver or driver compartment (HVAC system);
Changed in this version‘air conditioning system for passenger compartment’ means that a system is installed in the vehicle that can cool down the cabin air or fresh air supplied to the passenger compartment (HVAC system);
Changed in this version‘independent heat pump for driver compartment’ means that a heat pump is installed in the vehicle that is only used for the driver compartment (HVAC system);
Changed in this version‘heat pump 2-stage’ means a heat pump where the grade of actuation can be made in two steps only but not continuous variable (HVAC system);
Changed in this version‘heat pump 3-stage’ means a heat pump where the grade of actuation can be made in three steps only but not continuous variable (HVAC system);
Changed in this version‘heat pump 4-stage’ means a heat pump where the grade of actuation can be made in four steps only but not continuous variable (HVAC system);
Changed in this version‘heat pump continuous’ means a heat pump where the grade of actuation is continuously variable or where the air conditioning compressor is driven by an electric motor with continuously variable speed (HVAC system);
Changed in this version‘auxiliary heater power’ as stated on the label defined in paragraph 4 of Annex 7 to UN Regulation No. 122 ( *4 ) (HVAC system);
Changed in this version‘double glazing’ means windows of the passenger compartment that consist of two glass window panes that are separated by gas filled space or by vacuum. In the case of several types of windows within the passenger compartment, the predominant window type with regards to surface area has to be selected. For the assessment of the predominant window type the windscreen, the rear window, the driver side-window(s), windows within doors, windows above and in front of the front axle (see Figure 1 for examples) as well as tiltable windows, shall not be considered (HVAC system);
Changed in this versionFigure 1
Windows not to be considered for predominant window type
‘heat pump’ means a system that uses a refrigerant in a circular process to transfer thermal energy from the environment to the passenger compartment and/or the driver compartment and/or transfers thermal energy in the opposite direction (cooling and/or heating functionality) with a coefficient of performance larger than 1 (HVAC system);
Changed in this version‘R-744 heat pump’ means a heat pump which uses R-744 refrigerant as working medium (HVAC system);
Changed in this version‘non R-744 heat pump’ means a heat pump which uses another working medium than R-744 refrigerant. For the possible grade of actuation (2-stage, 3-stage, 4-stage, continuous), the definitions (56) to (59) shall apply (HVAC system);
Changed in this version‘adjustable coolant thermostat’ means a coolant thermostat which characteristics are influenced by at least one additional input besides the coolant temperature, e.g. active electric heating of the thermostat (HVAC system);
Changed in this version‘adjustable auxiliary heater’ means a fuel-operated heater with at least 2 levels of heating capacity besides ‘off’ that can be controlled depending on the required heating system capacity in the bus (HVAC system);
Changed in this version‘engine waste gas heat exchanger’ means a heat exchanger that uses the thermal energy of engine waste gas to heat the cooling circuit (HVAC system);
Changed in this version‘separate air distribution ducts’ means one or multiple air channels connected to a thermal comfort system to distribute conditioned air evenly to the passenger compartment. Air channels may include loud speakers or HVAC water supply and electric harness. Reservoirs for compressed airs shall not be installed within this/these channel/s. By this model parameter the simulation tool considers reduced heat transfer losses to the ambient or components within the channel. For HVAC configurations 8, 9 and 10 in vehicle groups 31, 33, 35, 37 and 39, this input shall be set to ‘true’ as those configurations benefit from reduced losses as cooled air is directly blown into vehicle interior even without any air channel. For all HVAC configurations in vehicle groups 32, 34, 36, 38 and 40 this parameter shall be set to ‘true’ as this is state-of-the-art (HVAC system);
Changed in this version‘electrically driven compressor’ means a compressor driven by an electric motor (pneumatic system);
Changed in this version‘water electric heater’ means a device using electric energy to heat up the coolant of the vehicle with a coefficient of performance lower than 1 and that is actively used for the heating functionality during vehicle operation on road (HVAC system);
Changed in this version‘air electric heater’ means a device using electric energy to heat up the air of the passenger and/or driver compartment with a coefficient of performance lower than 1 (HVAC system);
Changed in this version‘other heating technology’ means any fully electric technology used for heating up the passenger and/or driver compartment not covered by the technologies in definitons (62), (70) or (71) (HVAC system);
Changed in this version‘lead-acid battery – conventional’ means a lead-acid battery where none of the definitions (74) or (75) applies (electric system);
Changed in this version‘lead-acid battery –AGM’ (Absorbed Glass Mat) means lead-acid batteries where glass fibre mats soaked in electrolyte are used as separators between the negative and positive plates (electric system);
Changed in this version‘lead-acid battery – gel’ means lead-acid batteries where a silica gelling agent is mixed into the electrolyte (electric system);
Changed in this version‘Li-ion battery - high power’ means a Li-ion battery where the numerical ratio between rated maximum current in [A] and the rated capacity in [Ah] is equal to or larger than 10 (electric system);
Changed in this version‘Li-ion battery - high energy’ means a Li-ion battery where the numerical ratio between rated maximum current in [A] and the rated capacity in [Ah] is less than 10 (electric system);
Changed in this version‘capacitor with DC/DC converter’ means an (ultra) capacitor electrical energy storage unit combined with a DC/DC unit that adapts the voltage level and controls the current to and from the electric consumer board net (electric system);
Changed in this version‘articulated bus’ means a heavy bus that is an incomplete vehicle, complete vehicle or completed vehicle consisting of at least two rigid sections connected to each other by an articulated section. Connection and disconnection of the sections are to be possible only in a workshop. For the complete or completed heavy buses of this type of vehicle, the articulated section shall permit the free movement of travellers between the rigid sections.
Changed in this version3. Description of auxiliary relevant input information into the simulation tool
3.1. Engine cooling fan
3.2. Steering system
3.3. Electric System
3.3.1. Medium lorries and heavy lorries
3.3.2. Heavy buses
3.4. Pneumatic system
3.4.1. Pneumatic systems working with over pressure
3.4.1.1. Size of air supply
3.4.1.2. Fuel saving technologies
3.4.1.3. Further characteristics of the pneumatic system for heavy buses
3.4.2. Pneumatic systems working with vacuum
3.5. HVAC system
3.5.1. HVAC system for medium lorries and heavy lorries
3.5.2. HVAC system for heavy buses
Figure 2
HVAC system configuration for heavy buses (Rigid and Articulated)
3.6 Transmission Power Take-Off (PTO)
ANNEX X
CERTIFICATION PROCEDURE FOR PNEUMATIC TYRES
1. Introduction
2. Definitions
‘Rolling resistance coefficient Cr’ means a ratio of the rolling resistance to the load on the tyre
Changed in this version‘The load on the tyre FZTYRE’ means a load applied to the tyre during the rolling resistance test.
Changed in this version‘Type of tyre’ means a range of tyres which do not differ in such characteristics as:
Changed in this versionManufacturer's name;
Changed in this versionBrand name or trade mark
►M3
; ◄
Changed in this versionTyre class (in accordance with UN Regulation No. 117);
Changed in this versionTyre-size designation;
Changed in this versionTyre structure (diagonal (bias-ply), radial);
Changed in this versionCategory of use (normal tyre, snow tyre, special use tyre) as defined in
►M3
UN ◄ Regulation No.117;
Changed in this versionSpeed category (categories);
Changed in this versionLoad-capacity index (indices);
Changed in this versionTrade description/commercial name;
Changed in this versionDeclared tyre rolling resistance coefficient
Changed in this version‘FuelEfficiencyClass’ is a parameter corresponding to the fuel efficiency class of the tyre as defined in Regulation (EU) 2020/740 ( 19 ) Annex I, part A. For tyres which are not in the scope of Regulation (EU) 2020/740, the fuel efficiency class of the tyre is not applicable and parameter FuelEfficiencyClass shall be recorded in Appendix 3 as ‘N/A’.
Changed in this version3. General requirements
4. Conformity of the certified CO2 emissions and fuel consumption related properties
Appendix 1
MODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UNIT OR SYSTEM
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PROPERTIES OF A TYRE FAMILY
Manufacturer's name and address: …
Changed in this versionIf applicable, name and address of manufacturer's representative: …
Changed in this versionBrand name/trade mark: …
Changed in this versionTyre type description: …
Changed in this versionManufacturer's name …
Changed in this versionBrand name or trade mark
Changed in this versionTyre class (in accordance with Regulation (EC) No 661/2009 or Regulation (EU) 2019/2144)
Changed in this versionTyre-size designation …
Changed in this versionTyre structure (diagonal (bias-ply); radial) …
Changed in this versionCategory of use (normal tyre, snow tyre, special use tyre) …
Changed in this versionSpeed category (categories) …
Changed in this versionLoad-capacity index (indices) …
Changed in this versionTrade description/commercial name …
Changed in this versionDeclared tyre rolling resistance coefficient …
Changed in this versionTyre identification code(s) and technology(ies) used to provide identification code(s), if applicable:
| Technology: | Code: |
| … | … |
Technical Service and, where appropriate, test laboratory approved for purposes of approval or of verification of conformity tests: …
Changed in this versionDeclared values: declared rolling resistance level of the tyre (in N/kN rounded to the first decimal place, in accordance with ISO 80000-1 Appendix B, section B.3, rule B (example 1)) Cr, … [N/kN] tyre test load in accordance with Regulation (EU) 2020/740, Annex I, part A FZTYRE… [N] Alignment equation: …
Changed in this versionAny remarks: …
Changed in this versionPlace: …
Changed in this versionDate: …
Changed in this versionSignature: …
Changed in this versionAnnexed to this communication are: …
Changed in this versionAppendix 2
Tyre rolling resistance coefficient information document
SECTION I
SECTION II
Appendix 3
Input parameters for the simulation tool
Introduction
Definitions
‘Parameter ID’:Unique identifier as used in the simulation tool for a specific input parameter or set of input data
| (2) | ‘Type’: |
Data type of the parameter
string …
sequence of characters in ISO8859-1 encoding
token …
sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace
date …
date and time in UTC time in the format: YYYY-MM-DD T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
integer …
value with an integral data type, no leading zeros, e.g. ‘1800’
double, X …
fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’
| string … | sequence of characters in ISO8859-1 encoding |
|---|---|
| token … | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date … | date and time in UTC time in the format: YYYY-MM-DD |
T HH:MM:SS Z with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’
| integer … | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X … | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345.67’; for ‘double, 4’: ‘45.6780’ |
‘Unit’ …physical unit of the parameter
Changed in this versionSet of input parameters
Appendix 4
Numbering
1. Numbering:
CONFORMITY OF SIMULATION TOOL OPERATION AND OF CO2 EMISSIONS
1. IntroductionThis Annex sets out the requirements for the verification testing procedure, which is the test procedure for verifying the CO2 emissions of new medium and heavy lorries. The verification testing procedure consists of an on-road test to verify the CO2 emissions of new vehicles after production. It shall be carried out by the vehicle manufacturer and supervised by the approval authority that granted the licence to operate the simulation tool. During the verification testing procedure the torque and speed at the driven wheels, the engine speed, the fuel consumption, the engaged gear of the vehicle and the other relevant parameters listed in point 6.1.6 shall be measured. The measured data shall be used as input to the simulation tool, which uses the vehicle-related input data and the input information from the determination of the CO2 emissions and fuel consumption of the vehicle. For the verification testing procedure simulation, the instantaneously measured wheel torque and the rotational speed of the wheels as well as the engine speed shall be used as input. To pass the verification testing procedure the CO2 emissions calculated from the measured fuel consumption shall be within the tolerances set out in point 7 compared to the CO2 emissions from the verification testing procedure simulation. Figure 1 gives a schematic picture of the verification testing procedure method. The evaluation steps as performed by the simulation tool in the verification testing procedure simulation are described in Appendix 1 of this Annex. As part of the verification testing procedure, the correctness of the vehicle input data set from the certification of CO2 emissions and fuel consumption related properties of the components, separate technical units and systems shall also be reviewed to check the data and the data handling process. The correctness of the input data relating to components, separate technical units and systems relevant for air drag and for rolling resistance of the vehicle shall be verified in accordance with point 6.1.1.
Figure 1
Schematic picture of the verification testing procedure meth
2. DefinitionsFor the purposes of this Annex the following definitions shall apply:
‘verification test relevant data set’ means a set of input data for components, separate technical units and systems and input information used for CO2 determination of a verification testing procedure relevant vehicle;
Changed in this version‘verification testing procedure relevant vehicle’ means a new vehicle for which a value of CO2 emissions and fuel consumption was determined and declared in accordance with Article 9;
Changed in this version‘corrected actual mass of the vehicle’ means the ‘corrected actual mass of the vehicle’ as defined in Annex III, point 2(4);
Changed in this version‘actual mass of the vehicle for VTP’ is the actual mass of the vehicle as defined in Article 2(6) of Regulation (EU) No 1230/2012, but with a full-tank and plus the additional measurement equipment as set out in point 5 (measurement equipment), plus the actual mass of the trailer or semitrailer if demanded by 6.1.4.1;
Changed in this version‘actual mass of the vehicle for VTP with payload’ means the actual mass of the vehicle for VTP with the payload applied in the verification testing procedure as set out in 6.1.4.2;
Changed in this version‘wheel power’ means the total power at the driven wheels of a vehicle to overcome all driving resistances at the wheel, computed in the simulation tool from the measured torque and rotational speed of the driven wheels;
Changed in this version‘controller area network signal’ or ‘CAN signal’ means a signal from the connection with the vehicle electronic control unit as referred to in point 2.1.5 of Appendix 1 to Annex II to Regulation (EU) No 582/2011;
Changed in this version‘urban driving’ means the total distance driven during the fuel consumption measurement at speeds not exceeding 50 km/h;
Changed in this version‘rural driving’ means the total distance driven during the fuel consumption measurement at speeds exceeding 50 km/h, but not exceeding 70 km/h;
Changed in this version‘motorway driving’ means the total distance driven in the fuel consumption measurement at speeds above 70 km/h;
Changed in this version‘crosstalk’ means the signal at the main output of a sensor (My), produced by a measurand (Fz) acting on the sensor, which is different from the measurand assigned to this output; the coordinate system assignment is defined in accordance with ISO 4130.
Changed in this version3. Vehicle selectionThe number of new vehicles to be tested per year of production ensures that the relevant variations of components, separate technical units or systems used are covered by the verification testing procedure. The vehicle selection for the verification test shall be based on the following requirements:
The vehicles for the verification test shall be selected out of the vehicles from the production line for which a value of CO2 emissions and fuel consumption has been determined and declared in accordance with Article 9. The components, separate technical units or systems mounted in or on the vehicle shall be out of series production and shall correspond to those mounted at production date of the vehicle.
Changed in this versionThe vehicle selection shall be made by the approval authority that granted the licence to operate the simulation tool based on proposals from the vehicle manufacturer.
Changed in this versionOnly vehicles with one driven axle shall be selected for verification test.
Changed in this versionIt is recommended to include in each verification test relevant data sets of the components of interest and with the highest sales numbers per manufacturer. The components, separate technical units or systems may be verified all in one vehicle or in different vehicles. Apart from the criterion of highest sales numbers, the approval authority mentioned in (b) shall decide whether other vehicles with relevant data sets engine, axle and transmission shall be included in the verification test.
Changed in this versionVehicles which use standard values for CO2 certification of their components, separate technical units or systems instead of measured values for the transmission and for the axle losses shall not be selected for the verification test as long as vehicles complying with the requirements in points (a) to (c) and using measured loss maps for these components, separate technical units or systems in the CO2 certification, are produced.
Changed in this versionThe minimum number of different vehicles with different combinations of verification test relevant data sets to be tested by verification test per year shall be based on the sales numbers of the vehicle manufacturer as set out in Table 1. Table 1 Determination of the minimum number of vehicles to be tested by the vehicle manufacturer
| Number of vehicles to be tested | Schedule | Verification testing procedure relevant vehicles produced / year (*2) |
|---|---|---|
| 0 | — | ≤ 25 |
| 1 | every 3 years (*1) | 26 – 250 |
| 1 | every 2 years | 251 – 5 000 |
| 1 | every year | 5 001 – 25 000 |
| 2 | every year | 25 001 – 50 000 |
| 3 | every year | 50 001 – 75 000 |
| 4 | every year | 75 001 – 100 000 |
| 5 | every year | more than 100 000 |
(*1) The total of all vehicles by a manufacturer falling within the scope of this regulation is to be considered and both medium lorries as well as heavy lorries need to be covered by the VTP over a six-year time span.
(*2) The VTP shall be performed within the first two years.
Changed in this versionThe vehicle manufacturer shall finalize the verification test within a period of 10 months after the date of selection of the vehicle for the verification test.
Changed in this version4. Vehicle conditionsEach vehicle for the verification test shall be in the condition resembling its intended placing on the market. No changes in hardware such as lubricants or in the software such as auxiliary controllers are allowed. The tyres may be replaced by measurement tyres of similar size (± 10 %). The provisions as set out in points 3.3 to 3.6 of Annex II to Regulation (EU) 582/2011 shall apply.
4.1 Vehicle run inRun in of the vehicle is not mandatory. If the total mileage of the test vehicle is less than 15 000 km, an evolution coefficient for the test result is applied by the simulation tool as defined in Appendix 1. The total mileage of the test vehicle shall be the odometer reading at start of the fuel consumption measurement. The maximum mileage at start of the warm-up shall be 20 000 km.
4.2 Fuel and lubricantsAll lubricants shall be the same as the lubricants used when placing the vehicle on the market. For the fuel consumption measurement as described in point 6.1.5 the fuel used shall be the one available on the market. In any case of dispute the fuel shall be the appropriate reference fuel specified in Annex IX to Regulation (EU) No 582/2011. The fuel tank shall be full at start of the vehicle warm up. Refuelling of the vehicle between start of warm up and end of fuel consumption measurement is not allowed. The net calorific value (NCV) of the fuel used in the verification test shall be determined in accordance with point 3.2 of Annex V. The fuel batch shall be taken from the tank after vehicle warm-up. In the case of dual-fuel engines, this procedure shall be applied to both fuels.
5. Measurement equipmentThe calibration laboratory facilities shall comply with the requirements of either IATF 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and verification, shall be traceable to national or international standards.
5.1 Wheel torqueThe direct torque at all driven axles shall be measured with one of the following measurement systems fulfilling the requirements listed in Table 2:
hub torque meter;
Changed in this versionrim torque meter;
Changed in this versionhalf-shaft torque meter. The drift shall be measured during the verification test by zeroing the torque measurement system in accordance with point 6.1.5.4 after the vehicle warm up in accordance with point 6.1.5.3. by lifting the axle and measuring the torque at lifted axle directly after the verification test again in accordance with point 6.1.5.6. For a valid test result a maximum drift (sum of absolute values of both wheels) of the torque measurement system over the verification testing procedure of 1,5 % of the calibrated range of a single torque meter shall be proven.
Changed in this version5.2 Vehicle speedThe recorded vehicle speed shall be based on the CAN signal.
5.3 Gear engagedFor vehicles with SMT and AMT transmissions the engaged gear is calculated by the simulation tool based on measured engine speed, the vehicle speed and the tyre dimensions and transmission ratios of the vehicle in accordance with Appendix 1. The engine speed is taken by the simulation tool from the input data as defined in point 5.4. For vehicles with APT transmissions the engaged gear as well as the status of the torque converter (active or not active) shall be provided from CAN signals.
5.4 Rotational speed of the engineThe rotational speed of the engine shall be recorded from the CAN, OBD or alternative measurement systems that fulfil the requirements set out in Table 2.
5.5 Rotational speed of the wheels at the driven axleThe rotational speed of the left and right wheel of the driven axle shall be recorded from the CAN or alternative measurement systems that fulfil the requirements set out in Table 2.
5.6 Rotational speed of fanFor non-electrically driven engine cooling fans the rotational speed of the fan shall be recorded. For this purpose either the CAN signal or alternatively an external sensor fulfilling the requirements set out in Table 2 shall be used. For electrically driven engine cooling fans the current and voltage shall be recorded for the direct current input at the terminal of the electric motor or the inverter. From these two signals, the electrical power at the terminal shall be calculated by multiplication and shall be available as a time-resolved signal as input to the simulation tool. In the case of multiple electrically driven engine cooling fans, the sum of electrical power at the terminals shall be made available.
5.7 Fuel measurement systemThe fuel consumed shall be measured on-board with a measurement device based on one of the following measurement methods:
m fuel,i = V fuel,i ·ρi where:
| mfuel, i | = | Fuel mass flow at sample i [g/h] |
|---|---|---|
| ρ0 | = | Density of the fuel used for the verification test in (g/dm3). The density shall be determined in accordance with Annex IX to the Regulation (EU) No 582/2011. If diesel fuel is used in the verification test, also the average value of the density interval for the reference fuels B7 in accordance with Annex IX to the Regulation (EU) No 582/2011 may be used. |
| t0 | = | Fuel temperature that corresponds to density ρ0 for the reference fuel [°C] |
| ρi | = | Density of the test fuel at sample i [g/dm3] |
| Vfuel, i | = | Fuel volume flow at sample i [dm3/h] |
| ti | = | Measured fuel temperature at sample i [°C] |
| β | = | Temperature correction factor (0,001 K–1). |
For dual-fuel vehicles the fuel flow shall be measured for each of the two fuels separately.
Changed in this version5.8 Vehicle massThe following masses of the vehicle shall be measured with equipment fulfilling the requirements set out in Table 2:
actual mass of the vehicle for VTP;
Changed in this versionactual mass of the vehicle for VTP with payload.
Changed in this version5.9 General requirements for the on-board measurements as spThe input data as set out in point 6.1.6. Table 4 shall be provided from the measurements. All data shall be recorded at least in 2 Hz frequency or at recommended frequency from the equipment maker, whichever is the higher value. The input data for the simulation tool may be composed from different recorders. The torque and rotational speed at the wheels shall be recorded in one data-logging system. If different data-logging systems are used for the other signals, one common signal, such as vehicle speed, shall be recorded to ensure correct time alignment of the signals. The time alignment of the signals shall result in the highest correlation coefficient of the common signal recorded with the different data loggers. The accuracy requirements set out in Table 2 shall be met by all measurement equipment used. Any equipment not listed in Table 2 shall fulfil the accuracy requirements set out in Table 2 of Annex V. Table 2 Requirements of measurement systems Measurement system | Accuracy | Rise time (1) Balance for vehicle weight | 50 kg or < 0,5 % of max. calibration whichever is smaller | — Rotational speed wheels | < 0,5 % of reading at 80 km/h | ≤ 1 s Fuel mass flow for liquid fuels (2) | < 1,0 % of reading or < 0,2 % of max. calibration whichever is larger | — Fuel mass flow for gaseous fuels (2) | < 1,0 % of reading or < 0,5 % of max. calibration whichever is larger | — Fuel volume measurement system (2) | < 1,0 % of reading or < 0,5 % of max. calibration whichever is larger | — Temperature of the fuel | ± 1 °C | ≤ 2 s Sensor for measuring the rotational speed cooling fan | < 0,4 % of reading or < 0,2 % of max. calibration of speed whichever is larger | ≤ 1 s Voltage | < 2 % of reading or < 1 % of max. calibration of speed whichever is larger | ≤ 1 s Current | < 2 % of reading or < 1 % of max. calibration of speed whichever is larger | ≤ 1 s Engine speed | As set out in Annex V. In the case of vehicles with engine stop-start, it shall be verified that the engine speed is also recorded correctly for speeds below idle. Wheel torque | For 10 kNm calibration (over the entire calibration range): i. Non linearity (3): < ± 40 Nm for heavy lorries < ± 30 Nm for medium lorries ii. Repeatability (4): < ± 20 Nm for heavy lorries < ± 15 Nm for medium lorries iii. Crosstalk: < ± 20 Nm for heavy lorries < ± 15 Nm for medium lorries (only applicable for rim torque meters) iv. Measurement rate: ≥ 20 Hz | < 0,1 s (1) Rise time means the difference in time between the 10 % and 90 % response of the final analyser reading (t90 – t10). (2) The accuracy shall be met for the integral fuel flow over 100 minutes. (3) Non linearity means the maximum deviation between ideal and actual output signal characteristics in relation to the measured value in a specific measuring range. (4) Repeatability means closeness of the agreement between the results of successive measurements of the same measured value carried out under the same conditions of measurement. The maximum calibration values shall be the maximum expected values during all test runs for the respective measurement system, multiplied by an arbitrary factor larger than 1 and less or equal than 2. For the torque measurement system the maximum calibration may be limited to 10 kNm. In the case of dual-fuel engines, the maximum calibration value for the measurement system for fuel mass flow or fuel volume shall be determined following the requirements laid down in point 3.5 of Annex V. For fuel volume the maximum calibration value shall be determined by dividing the maximum calibration values for fuel mass flow by the density value ρ0 defined in accordance with point 5.7. Accuracy given shall be met by the sum of all single accuracies in the case more than one scale is used.
5.10. Engine torqueThe engine torque shall be recorded during the verification testing procedure for the purpose of evaluating pollutant emissions. The signal shall fulfil the provisions as specified for the engine torque signal in Table 1 of point 2.2 of Appendix 1 to Annex II to Regulation (EU) 582/2011.
5.11. Pollutant emissionsFor measurement of pollutant emissions the instrumentation and procedures as set out in Appendices 1 to 4 of Annex II to Regulation (EU) 582/2011 shall be used. The data evaluation shall provide instantaneous emission mass flows as set out in Table 4 of point 6.1.6. as input to the simulation tool. Based on these input signals the simulation tool automatically calculates the brake specific pollutant emissions measured in the verification test (BSEM) as set out in Part B of Appendix 1 of this Annex. These results are then automatically written into the output of the simulation tool according to point 8.13.14. The additional requirements set out in Regulation (EU) 582/2011 on data evaluation (e.g. work based windows, moving average windows), test start and trip shall not apply. In the verification test procedure, pass/fail criteria regarding pollutant emissions shall not apply.
6. Test procedure
6.1 Vehicle preparationThe vehicle shall be taken from the series production and selected as set out in point 3.
6.1.1 Verification of input information and input data and dThe manufacturer's records file and the customer information file for the vehicle selected shall be used as basis for verifying the input data. The vehicle identification number of the vehicle selected shall be the same as the vehicle identification number in the manufacturer's records file and the customer information file. Upon request by the approval authority that granted the licence to operate the simulation tool, the vehicle manufacturer shall provide, within 15 working days, the manufacturer's records file, the input information and input data necessary to run the simulation tool as well as the certificate of CO2 emissions and fuel consumption related properties for all relevant components, separate technical units or systems.
6.1.1.1 Verification of components, separate technical unitsThe following checks shall be performed for the components, separate technical units and systems mounted on the vehicle:
Simulation tool data integrity: the integrity of the cryptographic hash of the manufacturer’s records file in accordance with Article 9(3) re-calculated during the verification testing procedure with the hashing tool shall be verified by comparison with the cryptographic hash in the certificate of conformity;
Changed in this versionVehicle data: the vehicle identification number, axle configuration, selected auxiliaries and power take off technology, disabled gears in accordance with point 6.2 of Annex III and requirements on active aero devices as set out in point 3.3.1.5 of Annex VIII shall match the selected vehicle;
Changed in this versionEngine torque limitations declared in the input to the simulation tool are subject to a verification in the VTP if they are declared for any of the highest 50 % of the gears (e.g. for any of the gears 7 to 12 of a 12-gear transmission) and if one of the following cases shall apply:
Changed in this versionTorque limit declared on the vehicle level in accordance with point 6.1 of Annex III
Changed in this versionTorque limit declared in the input to the transmission component in accordance with parameter P157 in Table 2 of Appendix 12 of Annex VI and if the declared value does not exceed 90 % of the engine maximum torque For any of the torque limits subject to a verification it shall be demonstrated that the 99 % percentile of the engine torque recorded during the fuel consumption measurement in the relevant gear does not exceed the declared torque limit by more than 5 %. For this purpose the verification test shall cover phases of full throttle in the respective gears. The verification shall be performed based on recorded engine torque as set out in 5.10. The engine torque limitation verification may also be performed as a separate test only, consisting of dedicated full-load accelerations and with no other obligations on test evaluation.
Changed in this versionComponent, separate technical unit or system data: the certification number and the model type imprinted on the certificate of CO2 emissions and fuel consumption related properties shall match the component, separate technical unit or system installed in the selected vehicle;
Changed in this versionThe hash of the simulation tool input data and the input information shall match the hash imprinted on the certificate of CO2 emissions and fuel consumption related properties for the following components, separate technical units or systems:
Changed in this versionengines;
Changed in this versiontransmissions;
Changed in this versiontorque converters;
Changed in this versionother torque transferring components;
Changed in this versionadditional drivetrain components;
Changed in this versionaxles;
Changed in this versionbody or trailer air drag;
Changed in this versiontyres.
Changed in this version6.1.1.2 Verification of the vehicle massIf requested by the approval authority that granted the licence to operate the simulation tool, the determination of masses by the manufacturer shall be verified in accordance with point 2 of Appendix 2 of Annex I to Regulation (EU) No 1230/2012. Where that verification fails, the corrected actual mass as defined in point 2(4) of Annex III to this Regulation shall be determined.
6.1.1.3 Actions to be takenIn the case of discrepancies in the certification number or the cryptographic hash of one or more files regarding the components, separate technical units or systems listed in subpoints (1) to (8) of point 6.1.1.1 (e) the correct input data file fulfilling the checks in accordance with points 6.1.1.1 and 6.1.1.2 shall replace the incorrect data for all further actions. The same applies to any other incorrect information identified in subpoints (b) and (c) of point 6.1.1.1. If the verification of results in the manufacturer's records file and the customer information file fails or no complete input data set with correct certificates of CO2 emissions and fuel consumption related properties is available for the components, separate technical units or systems listed in subpoints (1) to (8) of point 6.1.1.1 (e) the verification test shall end and the vehicle fails the verification testing procedure.
6.1.2 Run in phaseA run in phase up to maximum 15 000 km odometer reading may take place. In the case of damage of any of the components, separate technical units or systems listed in point 6.1.1.1, the component, separate technical units or systems may be replaced by an equivalent component, separate technical units or systems with the same certification number. The replacement shall be documented in the test report. All relevant components, separate technical units or systems shall be checked before the measurements to exclude unusual conditions, such as incorrect oil fill levels, plugged air filters or on-board diagnostic warnings.
6.1.3 Set up of measurement equipmentAll measurement systems shall be calibrated in accordance with the provisions of the equipment maker. If no provisions exist, the recommendations from the equipment maker shall be followed for calibration. After the run in phase, the vehicle shall be equipped with the measurement systems set out in point 5.
6.1.4 Set up of the test vehicle for the fuel consumption me
6.1.4.1 Vehicle configurationTractors of the vehicle groups defined in Table 1 and 2 of Annex I shall be tested with any type of semitrailer, providing the payload defined below can be applied. Rigid lorries of the vehicle groups defined in Table 1 and 2 of Annex I shall be tested with trailer, if a trailer connection is mounted. Any body type or other device to carry the payload set out in point 6.1.4.2 can be applied. The bodies of rigid lorries may differ from the standard bodies set out in Appendix 4, point 2, of Annex VIII. Vans of the vehicle groups defined in Table 2 of Annex I shall be tested with the final bodies of the complete or completed vehicle.
6.1.4.2 Vehicle payloadFor heavy lorries of groups 4 and higher numbers the vehicle payload shall be set at minimum to a mass leading to a total test weight of 90 % of the maximum authorised weight in accordance with 96/53/EC (*) for the specific vehicle or vehicle combination. For heavy lorries of groups 1s, 1, 2 and 3, and medium lorries the payload shall be in the range of 55 % to 75 % of the maximum authorised weight in accordance with 96/53/EC for the specific vehicle or vehicle combination.
6.1.4.3 Tyre inflation pressureThe tyre inflation pressure shall be set to the recommendation of the manufacturer with a maximum deviation of less than 10 %. The tyres of the semitrailer may differ from the standard tyres set out in Table 2 of Part B of Annex II to Regulation (EC) No 661/2009 for the CO2 certification of tyres.
6.1.4.4 Settings for auxiliariesAll settings influencing the auxiliary energy demand shall be set to minimum reasonable energy consumption where applicable. The air conditioning shall be switched off and venting of the cabin shall be set lower than medium mass flow. Additional energy consumers not necessary to run the vehicle shall be switched off. External devices to provide energy on board, such as external batteries, are allowed only for running the extra measurement equipment for the verification testing procedure listed in Table 2, but shall not provide energy to vehicle equipment that will be present when placing the vehicle on the market.
6.1.4.5 Particle filter regenerationA particle filter regeneration shall, if applicable, be initiated before the verification test. Regulation (EU) 582/2011, Annex II, point 4.6.10 shall apply.
6.1.5 Verification test
6.1.5.1 Route selectionThe route selected for the verification test shall fulfil the requirements set out in Table 3. The routes may include both public and private tracks.
6.1.5.2 Vehicle pre conditioningNo other pre-conditioning is allowed than the pre-condition in accordance with point 6.1.5.3.
6.1.5.3 Vehicle warm upBefore the fuel consumption measurement starts, the vehicle shall be driven for warm up as set out in Table 3. The warm up phase shall not be considered in the evaluation of the verification test. Before warm up is started, the PEMS analysers shall be checked and calibrated in accordance with the procedures as set out in Appendix 1 of Annex II to Regulation (EU) 582/2011.
6.1.5.4 Zeroing of the torque measurement equipmentThe zeroing of the torque meters shall be performed as follows:
6.1.5.5 Fuel consumption measurement and recording of pollutThe fuel consumption measurement shall start directly after the zeroing of the wheel-torque measurement equipment at vehicle stand still. The vehicle shall be driven during the measurement in a driving style avoiding unnecessary braking of the vehicle, gas pedal pumping and aggressive cornering. The setting for the advanced driver assistance systems which is activated automatically at key-on shall be used, and gear shifts shall be performed by the automated system (in the case of AMT or APT transmissions) and the cruise control shall be used (if applicable). The duration of the fuel consumption measurement shall be within the tolerances set out in Table 3. The fuel consumption measurement shall end also at vehicle stand still directly before the measurement of the drift of the torque measurement equipment. The recording of signals relevant for the evaluation of pollutant emissions shall start latest once the fuel consumption measurement has started and end together with the fuel consumption measurement. As input to the simulation tool the entire test sequence, starting with the last 0,5 s time step of the standstill phase after the zeroing of torque meters and ending with the first 0,5 s time step of the final standstill phase, shall be provided.
6.1.5.6 Measurement of the drift of the torque measurement eDirectly after the fuel consumption measurement, the drift of the torque measurement equipment shall be recorded by measuring the torque at the same vehicle conditions as during the zeroing process. If the fuel consumption measurement does end before the stop for the drift measurement, the vehicle shall be stopped for the drift measurement within 5 minutes. The drift of each torque meter shall be calculated from the average of a minimum sequence of 10 seconds. Directly thereafter, the verification of the emission measurements shall be performed in accordance with the procedures as set out in point 2.7 of Appendix 1 to Annex II to Regulation (EU) 582/2011.
6.1.5.7 Boundary conditions for the verification testThe boundary conditions to be met for a valid verification test are set in Tables 3 to 3b. If the vehicle passes the verification test in accordance with point 7.3, the test shall be set valid even if the following conditions are not met:
Table 3 Parameters for a valid verification test for all vehicle groups
| No. | Parameter | Min. | Max. |
|---|---|---|---|
| 1 | Warm up [minutes] | 60 | |
| 2 | Average velocity at warm up [km/h] | 70 (1) | 100 |
| 3 | Fuel consumption measurement duration [minutes] | 80 | 120 |
| 8 | Average ambient temperature | 5°C | 30 C |
| 9 | Road condition dry | 100 % | |
| 10 | Road condition snow or ice | 0 % | |
| 11 | Sea level of the route [m] | 800 | |
| 12 | Duration of continuous idling at stand still [minutes] | 3 |
(1) Where the maximum vehicle speed is less than 80 km/h, the average velocity in the warm-up shall exceed maximum vehicle speed minus 10 km/h. Table 3a Parameters for a valid verification test for vehicle groups 4, 5, 9, 10
| No. | Parameter | Min. | Max. |
|---|---|---|---|
| 4 | Distance based share urban driving | 2 % | 8 % |
| 5 | Distance based share rural driving | 7 % | 13 % |
| 6 | Distance based share motorway driving | 79 % | — |
| 7 | Time share of idling at stand still | 5 % |
Table 3b Parameters for a valid verification test for other heavy and medium lorries
| No. | Parameter | Min. | Max. |
|---|---|---|---|
| 4 | Distance based share urban driving | 10 % | 50 % |
| 5 | Distance based share rural driving | 15 % | 25 % |
| 6 | Distance based share motorway driving | 25 % | — |
| 7 | Time share of idling at stand still | 10 % |
In the event of extraordinary traffic conditions the verification test shall be repeated.
Changed in this version6.1.6 Data reportingThe data recorded during the verification testing procedure shall be reported to the approval authority that granted the licence to operate the simulation tool as follows: The data recorded shall be reported in a constant 2 Hz signals as set out in Table 4. The data recorded at higher frequencies than 2 Hz shall be converted into 2 Hz by averaging the time intervals around the 2 Hz nodes. In the case of e.g. 10 Hz sampling, the first 2 Hz node is defined by the average from second 0,1 to 0,5, the second node is defined by the average from second 0,6 to 1,0. The time stamp for each node shall be the last time stamp per node, i.e. 0,5, 1,0, 1,5 etc. Table 4 Data reporting format for measured data for the simulation tool in the verification test Quantity | Unit | Heading input data | Comment time node | [s] | <t> vehicle speed | [km/h] | <v> engine speed | [rpm] | <n_eng> engine cooling fan speed | [rpm] | <n_fan> | In the case of non-electrically driven engine cooling fans engine cooling fan electrical power | [W] | <Pel_fan> | In the case of electrically driven engine cooling fans torque left wheel | [Nm] | <tq_wh_left> torque right wheel | [Nm] | <tq_wh_right> wheel speed left | [rpm] | <n_wh_left> wheel speed right | [rpm] | <n_wh_right> gear | [-] | <gear> | mandatory for APT transmissions Torque converter active | [-] | <TC_active> | 0 = not active (locked); 1 = active (unlocked); mandatory for AT transmissions, not relevant for other transmission types fuel flow | [g/h] | <fc_X> | Fuel mass flow in accordance with point 5.7 (1). In the heading ‘X’ shall be the fuel type in accordance with Table 2 of Appendix 7 of Annex V to this Regulation, e.g. ‘<fc_Diesel CI>’. For dual-fuel engines a separate column for each fuel shall be provided. Engine torque | [Nm] | <tq_eng> | Engine torque in accordance with point 5.10. CH4 mass flow | [g/s] | <CH4> | Only if this component needs to be measured in accordance with point 1 of Appendix 1 of Annex II to Regulation (EU) 582/2011 CO mass flow | [g/s] | <CO> NMHC mass flow | [g/s] | <NMHC> | Only if this component needs to be measured in accordance with point 1 of Appendix 1 of Annex II to Regulation (EU) 582/2011 NOx mass flow | [g/s] | <NOx> THC mass flow | [g/s] | <THC> | Only if this component needs to be measured in accordance with point 1 of Appendix 1 of Annex II to Regulation (EU) 582/2011 PM number flow | [#/s] | <PN> CO2 mass flow | [g/s] (1) The correction of fuel flow to standard NCV is performed automatically by the simulation tool based on the input of net calorific value (NCV) of the fuel used in the verification test in accordance with Table 4a. Additionally the data as set out in Table 4a shall be reported. This data shall be entered directly into the graphical user interface of the simulation tool when evaluating the verification test procedure. Table 4a Data reporting format for further information for the simulation tool in the verification test Quantity | Unit | Comment NCV measured | [MJ/kg] | Net calorific value (NCV) of the fuel used in the verification test determined in accordance with point 3.2 of Annex V. This input shall be provided for all fuel types, i.e. also for Diesel CI engines (1). In the case of dual-fuel engines, values for both fuels shall be provided. Run-in distance | [km] | In accordance with point 6.1.2. Based on this input the simulation tool corrects the measured fuel consumption in accordance with Appendix 1. Diameter fan | [mm] | Diameter of the engine cooling fan. This input is not relevant for electrically driven engine cooling fans. Torque meter drift left wheel | [Nm] | Average torque meter readings in accordance with point 6.1.5.6. Torque meter drift right wheel | [Nm] (1) In the VTP test, the vehicle may be operated with market Diesel fuel. Contrary to the situation for reference Diesel fuel (B7), the variation of the NCV for market fuel is assessed to be greater than the measuring accuracy when determining the NCV.
7. Test evaluation
7.1. Input to the simulation tool
The following inputs to the simulation tool shall be made available: Input data and input information;
Changed in this versionManufacturer's records file;
Changed in this versionCustomer information file;
Changed in this versionProcessed measurement data in accordance with Table 4;
Changed in this versionFurther information in accordance with Table 4a.
Changed in this version7.2. Evaluation steps as performed by the simulation tool
7.2.1. Verification of the data handling processThe simulation tool shall re-simulate the CO2 emissions and fuel consumption based on the input information and input data defined in 7.1. and verify the corresponding results in the manufacturer's records file and the customer information file as provided by the manufacturer. In the case of any deviations, the remedial measures referred to in Article 23 shall apply.
7.2.2. Determination of the CVTP ratioThe test evaluation shall compare CO2 emissions during the measurement with simulated CO2 emissions. For this comparison the ratio of measured and simulated brake specific CO2 emissions for the total verification test relevant trip (CVTP) shall be calculated by the simulation tool in accordance with the following equation: Where: CVTP | = | ratio of CO2 emissions measured and simulated in the verification testing procedure (‘CVTP ratio’) n | = | number of fuels (2 for dual-fuel engines, else 1) CO2i | = | generic CO2 emission factor (grams CO2 per gram fuel) for the specific fuel type as implemented in the simulation tool. BSFCm-c | = | brake specific fuel consumption measured and corrected for a run-in phase as calculated in accordance with point 2 of part A in Appendix 1 [g/kWh] BSFCsim | = | brake specific fuel consumption determined by the simulation tool in accordance with point 3 of part A in Appendix 1 [g/kWh]
7.3. Pass/Fail checkThe vehicle shall pass the verification test if the CVTP ratio determined in accordance with 7.2.2. is equal or smaller than the tolerance set out in Table 5. For a comparison with the declared CO2 emissions of the vehicle in accordance with Article 9, the verified CO2 emissions of the vehicle are determined as follows: CO2verified = CVTP × CO2declared where: CO2verified | = | verified CO2 emissions of the vehicle in [g/t-km] CO2declared | = | declared CO2 emissions of the vehicle in [g/t-km] If a first vehicle fails the tolerances for CVTP, two more tests may be performed on the same vehicle or two more similar vehicles may be tested on request of the vehicle manufacturer. For the evaluation of the pass criterion set out in Table 5, the averages of the individual CVTP ratios from the up to three tests shall be used. If the pass criterion is not reached, the vehicle fails the verification testing procedure. Table 5 Pass fail criterion for the verification test Pass criterion for the verification testing procedure | CVTP ratio ≤ 1,075 Where CVTP is lower than 0,925, the results need to be reported to the Commission for further analysis to determine the cause.
8 Reporting proceduresThe test report shall be established by the vehicle manufacturer for each vehicle tested and shall include at least the following results of the verification test: 8.1. General 8.1.1. Name and address of the vehicle manufacturer 8.1.2. Address(es) of assembly plant(s) 8.1.3. The name, address, telephone and fax numbers and e-mail address of the vehicle manufacturer’s representative 8.1.4. Type and commercial description 8.1.5. Selection criteria for vehicle and CO2 relevant components (text) 8.1.6. Vehicle owner 8.1.7. Odometer reading at test start of the fuel consumption measurement (km) 8.2. Vehicle information 8.2.1. Vehicle model / Commercial Name 8.2.2. Vehicle identification number (VIN) 8.2.2.1. Where the test has been performed following a situation in which the first vehicle test ends in failing the tolerances referred to in point 7.3, the vehicle identification number (VIN) of the vehicle tested first 8.2.3. Vehicle category (N2, N3) 8.2.4. Axle configuration 8.2.5. Technically permissible maximum laden mass (t) 8.2.6. Vehicle group 8.2.7. Corrected actual mass of the vehicle (kg) 8.2.8. Cryptographic hash of the manufacturer's records file 8.2.9. Vehicle combination's gross combined weight in the verification test (kg) 8.2.10. Mass in running order 8.3. Main engine specifications 8.3.1. Engine model 8.3.2. Engine certification number 8.3.3. Engine rated power (kW) 8.3.4. Engine capacity (l) 8.3.5. Engine reference fuel type (diesel/LPG/CNG…) 8.3.6. Hash of the fuel map file/document 8.4. Main transmission specifications 8.4.1. Transmission model 8.4.2. Transmission certification number 8.4.3. Main option used for generation of loss maps (Option1/Option2/Option3/Standard values) 8.4.4. Transmission type 8.4.5. Number of gears 8.4.6. Transmission ratio final gear 8.4.7. Retarder type 8.4.8. Power take off (yes/no) 8.4.9. Hash of the efficiency map file/document 8.5. Main retarder specifications 8.5.1. Retarder model 8.5.2. Retarder certification number 8.5.3. Certification option used for generation of a loss map (standard values/measurement) 8.5.4. Hash of the retarder efficiency map file/document 8.6. Torque converter specification 8.6.1. Torque converter model 8.6.2. Torque converter certification number 8.6.3. Certification option used for generation of a loss map (standard values/measurement) 8.6.4. Hash of the efficiency map file/document 8.7. Angle drive specifications 8.7.1. Angle drive model 8.7.2. Axle certification number 8.7.3. Certification option used for generation of a loss map (standard values/measurement) 8.7.4. Angle drive ratio 8.7.5. Hash of the efficiency map file/document 8.8. Axle specifications 8.8.1. Axle model 8.8.2. Axle certification number 8.8.3. Certification option used for generation of a loss map (standard values/measurement) 8.8.4. Axle type (e.g. standard single driven axle) 8.8.5. Axle ratio 8.8.6. Hash of the efficiency map file/document 8.9. Aerodynamics 8.9.1. Model 8.9.2. Certification option used for generation of CdxA (standard values /measurement) 8.9.3. CdxA Certification number (if applicable) 8.9.4. CdxA value 8.9.5. Hash of the efficiency map file/document 8.10. Main tyre specifications 8.10.1. Tyre certification number on all axles 8.10.2. Specific rolling resistance coefficient of all tyres on all axles 8.11. Main auxiliary specifications 8.11.1. Engine cooling fan technology 8.11.1.1 Engine cooling fan diameter 8.11.2. Steering pump technology 8.11.3. Electric system technology 8.11.4. Pneumatic system technology 8.12. Test conditions 8.12.1. Actual mass of the vehicle for VTP (kg) 8.12.2. Actual mass of the vehicle for VTP with payload (kg) 8.12.3. Warm up time (minutes) 8.12.4. Average velocity at warm up (km/h) 8.12.5. Fuel consumption measurement duration (minutes) 8.12.6. Distance based share urban driving (%) 8.12.7. Distance based share rural driving (%) 8.12.8. Distance based share motorway driving (%) 8.12.9. Time share of idling at stand still (%) 8.12.10. Average ambient temperature (°C) 8.12.11. Road condition (dry, wet, snow, ice, others please specify) 8.12.12. Maximum sea level of the route (m) 8.12.13. Maximum duration of continuous idling at stand still (minutes) 8.13. Results of the verification test 8.13.1. Average fan power calculated for the verification test by the simulation tool (kW) 8.13.2. Positive wheel work over the verification test calculated by the simulation tool (kWh) 8.13.3. Positive wheel work over the verification test measured (kWh) 8.13.4. NCV of the fuel(s) used in the verification test (MJ/kg) 8.13.5. Fuel consumption value(s) in the verification test measured (g/kWh) 8.13.5.1 CO2 emission value(s) in the verification test measured (g/kWh) 8.13.6. Fuel consumption value(s) in the verification test measured, corrected (g/kWh) 8.13.6.1 CO2 emission value(s) in the verification test measured, corrected (g/kWh) 8.13.7. Fuel consumption value(s) in the verification test simulated (g/kWh) 8.13.7.1 CO2 emission value(s) in the verification test simulated (g/kWh) 8.13.8. Fuel consumption in the verification test simulated (g/kWh) 8.13.8.1 CO2 emission in the verification test simulated (g/kWh) 8.13.9. Mission profile (long haul / long haul (EMS) / regional / regional (EMS) / urban / municipal / construction) 8.13.10. Verified CO2 emissions of the vehicle (g/tkm) 8.13.11. Declared CO2 emissions of the vehicle (g/tkm) 8.13.12. Ratio of fuel consumption measured and simulated in the verification testing procedure (CVPT) in (-) 8.13.13. Passed the verification test (yes/no) 8.13.14. Pollutant emissions in the verification test 8.13.14.1. CO (mg/kWh) 8.13.14.2. THC (**) (mg/kWh) 8.13.14.3. NMHC (***) (mg/kWh) 8.13.14.4. CH4 (***) (mg/kWh) 8.13.14.5. NOx (mg/kWh) 8.13.14.6. PM number (#/kWh) 8.13.14.7. Positive engine work (kWh) 8.14. Software and user information 8.14.1. Simulation tool version (X.X.X) 8.14.2. Date and time of the simulation 8.15. Input to the simulation tool as set out in point 7.1. 8.16. Simulation output data 8.16.1. The aggregated simulation results The comma separated values file of the same name as the job file and with an extension ‘.vsum’ comprising the aggregated results of the simulated verification test that is generated by the simulation tool in its graphical user interface (GUI) version (‘sum exec data file’). 8.16.2. The time resolved simulation results The comma separated values file with the name comprising the VIN and the measurement data file name and with an extension ‘.vmod’ comprising the time resolved results of the simulated verification test that is generated by the simulation tool in its graphical user interface (GUI) version (‘mod data file’). Appendix 1 Main evaluation steps and equations as performed by the simulation tool in a verification testing procedure simulation This Appendix describes the main evaluation steps and underlying basic equations that are applied by the simulation tool in a verification testing procedure simulation.
PART A: Determination of the CVTP factorFor the determination of the CVTP factor as described in point 7.2.2, the calculation procedures as set out below are applied: Calculation of wheel power The torque data as read from the processed measurement data in accordance with Table 4 is corrected for the torque meter drift as follows: where: i | = | index standing for left and right wheel of the driven axle Tcorr | = | drift corrected torque signal [Nm] T | = | torque signal before drift correction [Nm] Tdrift | = | torque meter drift as recorded during drift check at the end of the verification test [Nm] t | = | time node [s] tstart | = | first time stamp in the processed measurement data in accordance with Table 4 [s] tend | = | last time stamp in the processed measurement data in accordance with Table 4 [s] The wheel power is calculated from the corrected wheel torque and rotational wheel speed as follows: where: i | = | index standing for left and right wheel of the driven axle t | = | time node [s] Pwheel | = | wheel power [kW] nwheel | = | rotational wheel speed [rpm] Tcorr | = | drift corrected torque signal [Nm] The total wheel power is then calculated as the sum of the wheel power from left and right wheel: Determination of the measured brake specific fuel consumption (FCm-c) The result for ‘brake specific fuel consumption measured and corrected for a run-in phase’ (BSFCm-c) as applied for in 7.2.2 is calculated by the simulation tool as described below. In a first step the raw value for measured brake specific fuel consumption for the verification test BSFCm is calculated as follows: where: BSFCm | = | raw value for measured brake specific fuel consumption in the verification test [g/kWh] FCm (t) | = | instantaneous fuel mass flow measured during the verification test [g/s] Δt | = | time increment duration = 0,5 [s] Wwheel,pos,m | = | positive wheel work measured in the verification test [kWh] In a second step BSFCm is corrected for the net calorific value (NCV) of the fuel used in the verification test resulting in BSFCm,corr: where: BSFCm,corr | = | value for measured brake specific fuel consumption in the verification test corrected and for NCV influence [g/kWh] NCVmeas | = | NCV of the fuel used in the verification test determined in accordance with point 3.2 of Annex V [MJ/kg] NCVstd | = | standard NCV in accordance with Table 5 in point 5.4.3.1 of Annex V [MJ/kg] This correction is applied for all fuel types, i.e. also for Diesel CI engines (see footnote 2 in Table 4a). In a third step the correction for a run-in phase is applied: where: BSFCm-c | = | brake specific fuel consumption measured and corrected for a run-in phase ef | = | evolution coefficient of 0,98 mileage | = | run-in distance [km] For dual-fuel vehicles all three evaluation steps are performed separately for both fuels. Determination of the brake specific fuel consumption simulated by the simulation tool (BSFCsim) In the verification test mode of the simulation tool the measured wheel power is applied as input to the backward simulation algorithm. The gears engaged during the verification test are determined by calculating the engine speeds per gear at the measured vehicle speed and selecting the gear that provides the engine speed closest to the measured engine speed. For APT transmissions during phases with active torque converter, the actual gear signal from the measurement is used. The loss models for axle gear, angle drive, retarders, transmissions and PTOs are applied in a similar way as in the declaration mode of the simulation tool. For power demand of auxiliary units concerning steering pump, pneumatic system, electric system and HVAC system the generic values as implemented per technology in the simulation tool are applied. For calculation of the power demand of the engine cooling fan the following formulas are applied: Case a) non-electrically driven engine cooling fans: where: Pfan | = | power demand engine cooling fan [kW] t | = | time node [s] nfan | = | measured rotational speed of the fan [rpm] Dfan | = | diameter of the fan [mm] C1 | = | 7,32 kW C2 | = | 1 200 rpm C3 | = | 810 mm Case (b) electrically driven engine cooling fans: Pfan(t) = P el(t) . 1,05 Pfan | = | power demand engine cooling fan [kW] t | = | time node [s] Pel | = | electrical power at the terminals of the engine cooling fan(s) as measured in accordance with point 5.6.1. In the case of vehicles with engine stop-start events during the verification test, similar corrections for auxiliary power demand and energy to re-start the engine as applied in the declaration mode of the simulation tool are applied. The simulation of the engines instantaneous fuel consumption FCsim(t) is performed for each 0,5 second time interval as follows:
The brake specific fuel consumption calculated by the simulation tool BSFCm-c as applied in 7.2.2 for calculation of the CVTP factor is calculated as follows: where:
| BSFCsim | = | brake specific fuel consumption determined by the simulation tool for the verification test [g/kWh] |
|---|---|---|
| t | = | time node [s] |
| FCsim | = | engines instantaneous fuel consumption [g/s] |
| Δt | = | time increment duration = 0,5 [s] |
| FCESS,corr | = | correction of fuel consumption regarding auxiliary power demand resulting from engine stop start (ESS) as applied in the declaration mode of the simulation tool [g] |
| Wwheel,pos,sim | = | positive wheel work determined by the simulation tool for the verification test [kWh] |
| fs | = | Simulation rate = 2 [Hz] |
| Pwheel,sim | = | Simulated wheel power for the verification test [kW] |
In the case of dual-fuel engines, BSFCsim is determined for both fuels separately.
Changed in this versionPART B: Determination of the brake specific pollutant emissiThe engine power is calculated from the measured signals for engine speed and engine torque as follows: where: Peng,m | = | measured engine power in the verification test[kW] t | = | time node [s] neng | = | measured rotational engine speed [rpm] Teng | = | measured engine torque [Nm] The positive engine work measured in the verification test is calculated as follows: Weng,pos,m | = | positive engine work measured in the verification test [kWh] fs | = | sampling rate = 2 [Hz] tstart | = | first time stamp in the processed measurement data in accordance with Table 4 [s] tend | = | last time stamp in the processed measurement data in accordance with Table 4 [s] The brake specific pollutant emissions measured in the verification test BSEM are calculated as follows: where: BSEM | = | brake specific pollutant emissions measured in the verification test [g/kWh] EM | = | instantaneous pollutant emission mass flow measured during the verification test [g/s] (*) Council Directive 96/53/EC of 25 July 1996 laying down for certain road vehicles circulating within the Community the maximum authorized dimensions in national and international traffic and the maximum authorized weights in international traffic (OJ L 235, 17.9.96, p. 59). (**) Only if this component needs to be measured in accordance with point 1 of Appendix 1 to Annex II to Regulation (EU) 582/2011. (***) For positive ignition engines. ANNEX Xb
CERTIFICATION OF ELECTRIC POWERTRAIN COMPONENTS
1. IntroductionThe component test procedures described in this Annex shall produce input data relating to electric machine systems, IEPC, IHPC Type 1, battery systems and capacitor systems for the simulation tool.
2. Definitions and abbreviationsFor the purposes of this Annex, the following definitions shall apply:
‘battery control unit’ or ‘BCU’ means an electronic device that controls, manages, detects or calculates electric and thermal functions of the battery system and that provides communication between the battery system or battery pack or part of a battery pack and other vehicle controllers.
Changed in this version‘battery pack’ means a REESS (rechargeable electric energy storage system) that includes secondary cells or secondary cell assemblies, which are normally connected with cell electronics, power supply circuits and overcurrent shut-off device, including electrical interconnections and interfaces for external systems (examples of external systems are systems intended for thermal conditioning, high voltage and low voltage auxiliary and communication).
Changed in this version‘battery system’ means a REESS that consists of secondary cell assemblies or battery pack(s) as well as electrical circuits, electronics, interfaces for external systems (e.g. thermal conditioning system), BCUs and contactors.
Changed in this version‘representative battery subsystem’ means a subsystem of a battery system that consists of either secondary cell assemblies or battery pack(s) in serial and/or parallel configuration with electrical circuits, thermal conditioning system interfaces, control units and cell electronics.
Changed in this version‘cell’ means a basic functional unit of a battery, consisting of an assembly of electrodes, electrolyte, container, terminals and usually separators, that is a source of electric energy obtained by direct conversion of chemical energy.
Changed in this version‘cell electronics’ means an electronic device that collects and possibly monitors thermal or electric data of cells or cell assemblies or capacitors or capacitor assemblies and contains electronics for balancing between cells or capacitors, if necessary.
Changed in this version‘secondary cell’ means a cell which is designed to be electrically recharged by way of a reversible chemical reaction.
Changed in this version‘capacitor’ means a device for storage of electrical energy achieved by the effects of electrostatic double-layer capacitance and electrochemical pseudo capacitance in an electrochemical cell.
Changed in this version‘capacitor cell’ means a basic functional unit of a capacitor, consisting of an assembly of electrodes, electrolyte, container, terminals and usually separators.
Changed in this version‘capacitor control unit’ or ‘CCU’ means an electronic device that controls, manages, detects or calculates electric and thermal functions of the capacitor system and that provides communication between the capacitor system or capacitor pack or part of a capacitor pack and other vehicle controllers.
Changed in this version‘capacitor pack’ means a REESS that includes capacitor cells or capacitor assemblies normally connected with capacitor cell electronics, power supply circuits and overcurrent shut-off device, including electrical interconnections, interfaces for external systems and CCU. Examples of external systems are thermal conditioning, high voltage and low voltage auxiliary and communication.
Changed in this version‘capacitor system’ means a REESS that includes capacitor cells or capacitor assemblies or capacitor pack(s) as well as electrical circuits, electronics, interfaces for external systems (e.g. thermal conditioning system), CCU and contactors.
Changed in this version‘representative capacitor subsystem’ means a subsystem of a capacitor system that consists of either capacitor assemblies or capacitor pack(s) in serial and/or parallel configuration with electrical circuits, thermal conditioning system interfaces, control units and capacitor cell electronics.
Changed in this version‘nC’ means the current rate equal to n times the one hour discharge capacity expressed in ampere (i.e. current that takes 1/n hours to fully charge or discharge the tested device based on the rated capacity).
Changed in this version‘continuously variable transmission’ or ‘CVT’ means an automatic transmission that can change seamlessly through a continuous range of gear ratios.
Changed in this version‘differential’ means a device that splits a torque into two branches, e.g., for left- and right-hand side wheels, while allowing these branches to rotate at unequal speeds. The torque-splitting function can be biased or deactivated by a differential brake- or differential lock device (if applicable).
Changed in this version‘differential gear ratio’ means the ratio of differential input speed (towards the primary propulsion energy converter) over differential output speed (towards driven wheels) with both differential output shafts running at the same speed.
Changed in this version‘drivetrain’ means the connected elements of the powertrain for transmission of the mechanical energy between the propulsion energy converter(s) and the wheels.
Changed in this version‘electric machine’ (EM) means an energy converter transforming between electrical and mechanical energy.
Changed in this version‘electric machine system’ means a combination of electric powertrain components as installed in the vehicle comprising of an electric machine, inverter and electronic control unit(s), including connections and interfaces for external systems
Changed in this version‘electric machine type’ is either (a) an asynchronous machine (ASM), (b) an excited synchronous machine (ESM), (c) a permanent magnet synchronous machine (PSM), or (d) a reluctance machine (RM).
Changed in this version‘ASM’ means an asynchronous electric machine type in which the electric current in the rotor needed to produce torque is obtained by electromagnetic induction from the magnetic field of the stator winding.
Changed in this version‘ESM’ means an excited synchronous electric machine type which contains multiphase AC electromagnets on the stator that create a magnetic field which rotates in time with the oscillations of the line current. It requires direct current supplied to the rotor for excitation.
Changed in this version‘PSM’ means a permanent magnet sychronous electric machine type which contains multiphase AC electromagnets on the stator that create a magnetic field which rotates in time with the oscillations of the line current. Permanent magnets embedded in the steel rotor create a constant magnetic field.
Changed in this version‘RM’ means a reluctance electric machine type which contains multiphase AC electromagnets on the stator that create a magnetic field which rotates in time with the oscillations of the line current. It induces non-permanent magnetic poles on the ferromagnetic rotor which does not have any windings. It generates torque through magnetic reluctance.
Changed in this version‘housing’ means an integrated and structural part of the component, enclosing the internal units and providing protection against direct contact from any direction of access.
Changed in this version‘energy converter’ means a system where the form of energy output is different from the form of energy input.
Changed in this version‘propulsion energy converter’ means an energy converter of the powertrain which is not a peripheral device whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
Changed in this version‘category of propulsion energy converter’ means (i) an internal combustion engine, (ii) an electric machine, or (iii) a fuel cell.
Changed in this version‘energy storage system’ means a system which stores energy and releases it in the same form as the input energy.
Changed in this version‘propulsion energy storage system’ means an energy storage system of the powertrain which is not a peripheral device and whose output energy is used directly or indirectly for the purpose of vehicle propulsion.
Changed in this version‘category of propulsion energy storage system’ means (i) a fuel storage system, (ii) a rechargeable electric energy storage system (REESS), or (iii) a rechargeable mechanical energy storage system.
Changed in this version‘form of energy’ means (i) electrical energy, (ii) mechanical energy, or (iii) chemical energy (including fuels).
Changed in this version‘fuel storage system’ means a propulsion energy storage system that stores chemical energy as liquid or gaseous fuel.
Changed in this version‘gearbox’ means a device changing torque and speed with defined fixed ratios for each gear which may include the functionality of shiftable gears as well
Changed in this version‘gear number’ means an identifier for the different shiftable gears for forward direction in a transmission with specific gear ratios; the shiftable gear with the highest gear ratio gets assigned the number 1; the identifying number is increased by the increment of 1 for each gear in descending order of gear ratios.
Changed in this version‘gear ratio’ means the forward gear ratio of the speed of the input shaft (towards the primary propulsion energy converter) to the speed of the output shaft (towards driven wheels) without slip.
Changed in this version‘high-energy battery system’ or ‘HEBS’ means a battery system or representative battery subsystem, for which the numerical ratio between maximum discharge current in A, declared by the component manufacturer at a SOC of 50 % in accordance with point 5.4.2.3.2, and the nominal electric charge output in Ah at a 1C discharge rate at RT is lower than 10.
Changed in this version‘high-power battery system’ or ‘HPBS’ means a battery system or representative battery subsystem, for which the numerical ratio between maximum discharge current in A, declared by the component manufacturer at a SOC of 50 % in accordance with point 5.4.2.3.2, and the nominal electric charge output in Ah at a 1C discharge rate at RT is equal to or higher than 10.
Changed in this version‘integrated electric powertrain component’ or ‘IEPC’ means a combined system of an electric machine system together with the functionality of either a single- or multi-speed gearbox or a differential or both, characterised by at least one of the following features:
Changed in this versionAdditionally, an IEPC shall comply with the following criteria:
Changed in this version‘IEPC design type wheel motor’ means an IEPC with either one output shaft or two output shafts connected directly to the wheel hub(s) and where two configurations shall be distinguished for the purpose of this Annex:
Changed in this version‘integrated hybrid electric vehicle powertrain component type 1’ or ‘IHPC Type 1’ means a combined system of multiple electric machine systems together with the functionality of a multi-speed gearbox characterised by a shared housing of all components and at least one of the following features:
Changed in this versionAdditionally, an IHPC Type 1 shall comply with the following criteria:
Changed in this version‘internal combustion engine’ or ‘ICE’ means an energy converter with intermittent or continuous oxidation of combustible fuel transforming between chemical and mechanical energy.
Changed in this version‘inverter’ means an electric energy converter that changes direct electric current to single-phase or polyphase alternating electric currents
Changed in this version‘peripheral device’ means any energy consuming, converting, storing or supplying devices, where the energy is not directly or indirectly used for the purpose of vehicle propulsion but which are essential to the operation of the powertrain and are therefore considered to be part of the powertrain.
Changed in this version‘powertrain’ means the total combination in a vehicle of propulsion energy storage system(s), propulsion energy converter(s) and the drivetrain(s) providing the mechanical energy at the wheels for the purpose of vehicle propulsion, plus peripheral devices.
Changed in this version‘rated capacity’ means the total number of ampere-hours that can be withdrawn from a fully charged battery determined in accordance with point 5.4.1.3
Changed in this version‘rated speed’ means the highest rotational speed of the electric machine system where the overall maximum torque occurs
Changed in this version‘room temperature’ or ‘RT’ means that the ambient air inside the test cell shall have a temperature of (25 ± 10) °C
Changed in this version‘state of charge’ or ‘SOC’ means the available electrical charge stored in a battery system expressed as a percentage of its rated capacity in accordance with 5.4.1.3 (where 0 % represents empty and 100 % represents full)
Changed in this version‘unit under test’ or ‘UUT’ means the electric machine system, IEPC or IHPC Type 1 to be actually tested
Changed in this version‘battery UUT’ means the battery system or representative battery subsystem to be actually tested
Changed in this version‘capacitor UUT’ means the capacitor system or representative capacitor subsystem to be actually tested. For the purposes of this Annex, the following abbreviations shall apply:
| AC | alternating current |
|---|---|
| DC | direct current |
| DCIR | direct current internal resistance |
| EMS | electric machine system |
| OCV | open circuit voltage |
| SC | standard cycle |
3. General requirementsThe calibration laboratory facilities shall comply with the requirements of either IATF 16949, ISO 9000 series or ISO/IEC 17025. All laboratory reference measurement equipment, used for calibration and/or verification, shall be traceable to national or international standards.
3.1 Measurement equipment specificationsThe measurement equipment shall meet the following accuracy requirements: Table 1 Requirements of measurement systems Measurement system | Accuracy (1) Rotational speed | 0,5 % of the analyser reading or 0,1 % of max. calibration (2) of rotational speed whichever is larger Torque | 0,6 % of the analyser reading or 0,3 % of max. calibration (2) or 0,5 Nm of torque whichever is larger Current | 0,5 % of the analyser reading or 0,25 % of max. calibration (2) or 0,5 A of current whichever is larger Voltage | 0,5 % of the analyser reading or 0,25 % of max. calibration (2) of voltage whichever is larger Temperature | 1,5 K (1) ‘Accuracy’ means the absolute value of deviation of the analyser reading from a reference value which is traceable to a national or international standard. (2) The ‘maximum calibration’ value shall be the maximum predicted value for the respective measurement system expected during a specific test run performed in accordance with this Annex multiplied by a factor of 1.1. Multi-point calibration shall be allowed which means that a measurement system is allowed to be calibrated up to a nominal value which is less than the capacity of the measurement system.
3.2 Data recordingAll measurement data, except temperature, shall be measured with and recorded at a frequency of not less than 100 Hz. For temperature a measurement frequency of not less than 10 Hz is sufficient. Signal filtering may be applied in agreement with the approval authority. Any aliasing effect shall be avoided.
4. Testing of electric machine systems, IEPCs and IHPCs Type
4.1 Test conditionsThe UUT shall be installed and the measurands current, voltage, electric inverter power, rotational speed and torque shall be defined in accordance with Figure 1 and point 4.1.1.
Figure 1
Provisions for measurement of electric machine system or IEP
4.1.1 Equations for power figuresPower figures shall be calculated in accordance with the following equations:
4.1.1.1 Inverter powerThe electric power to or from the inverter (or DC/DC converter if applicable) shall be calculated in accordance with the following equation: PINV_in = VINV_in × IINV_in where: PINV_in | is the electric inverter power to or from the inverter (or DC/DC converter if applicable) on the DC side of the inverter (or on the side of the DC powersource of the DC/DC converter) [W] VINV_in | is the voltage at the inverter (or DC/DC converter if applicable) input on the DC side of the inverter (or on the side of the DC powersource of the DC/DC converter) [V] IINV_in | is the current at the inverter (or DC/DC converter if applicable) input on the DC side of the inverter (or on the side of the DC powersource of the DC/DC converter) [A] In the case of multiple connections of inverter(s) (or DC/DC converter(s) if applicable) to the electric DC powersource as defined in accordance with point 4.1.3, the total sum of all different electric inverter powers shall be measured.
4.1.1.2 Mechanical output powerThe mechanical output power of the UUT shall be calculated in accordance with the following equation: where PUUT_out | is the mechanical output power of the UUT [W] TUUT | is the torque of the UUT [Nm] n | is the rotational speed of the UUT [min–1] For an electric machine system the torque and speed shall be measured at the rotational shaft. For an IEPC the torque and speed shall be measured at the output side of the gearbox or, if a differential is also included, at the output side(s) of the differential. For an IEPC with integrated differential, the output torque measuring device(s) can either be installed on both output sides, or only one of the output sides. For test setups with only one dynamometer on the output side, the free rotating end of the IEPC with integrated differential shall be rotatably locked to the other end on the output side (e.g., by an activated differential lock or by means of any other mechanical differential lock implemented only for the measurement). In the case of an IEPC design type wheel motor, either one single component or two such components may be measured. Where two such components are measured, the following provisions shall apply, depending on the configuration:
Where the output torque measuring devices are installed on both output shafts, the following provisions shall apply:
Changed in this versionWhere an output torque measuring device is installed only on one of the output shafts, the following provisions shall apply:
Changed in this version4.1.2 Run-inOn request of the applicant a run-in procedure may be applied to the UUT. The following provisions shall apply for a run-in procedure:
4.1.3 Power supply to inverterThe power supply to the inverter (or DC/DC converter if applicable) shall be a direct-current constant-voltage power supply, which is capable of supplying/absorbing adequate electric power to/from the inverter (or DC/DC converter if applicable) at the maximum (mechanical or electrical) power of the UUT for the duration of the test runs specified in this Annex. The DC input voltage to the inverter (or DC/DC converter if applicable) shall be in a range of ±2 % of the requested target value of DC input voltage to the UUT during all periods where actual measurement data is recorded that is used as a basis for determining input data for the simulation tool. Table 2 in paragraph 4.2 defines which test runs shall be performed at which voltage level(s). There are 2 different voltage levels defined for the measurements to be performed:
4.1.4 Setup and wiringAll wiring, shielding, brackets, etc. shall be in accordance with conditions specified by the manufacturer(s) of the different components of the UUT.
4.1.5 Cooling systemThe temperature of all parts of the electric machine system shall be within the range allowed by the component manufacturer during the whole operating time of all test runs performed in accordance with this Annex. For IEPC and IHPC Type 1 this includes also all other components as gearboxes and axles being part of the IEPC or IHPC Type 1.
4.1.5.1 Cooling power during test runs
4.1.5.1.1 Cooling power for measurement of torque limitationFor all test runs performed in accordance with point 4.2, except for the EPMC in accordance with paragraph 4.2.6, the component manufacturer has to declare the number of used cooling circuits with connection to an external heat exchanger. For each of these circuits with connection to an external heat exchanger the following parameters at the inlet of the respective cooling circuit of the UUT shall be declared:
These declared values shall be documented in the information document for the respective component. The following actual values shall remain below the declared maximum values and be recorded for each cooling circuit with connection to an external heat exchanger, together with the test data for all different test runs performed in accordance with point 4.2 except for the EPMC in accordance with point 4.2.6:
Changed in this versionFor all test runs performed in accordance with point 4.2, the minimum temperature of the coolant at the inlet of the cooling circuit of the UUT, in the case of liquid cooling shall be 25 °C. Where fluids other than the regular cooling fluids are used for testing in accordance with this Annex, they must not exceed the temperature limits as defined by the component manufacturer. In the case of liquid cooling, the maximum available cooling power on the testbench shall be determined based on the coolant massflow, the temperature difference over the test bed heat exchanger on the side of the UUT and the specific heat capacity of the coolant. No additional fan with the purpose of actively cooling the components of the UUT shall be allowed in the test setup.
Changed in this version4.1.6 InverterThe inverter shall be operated in the same mode and settings as specified for the actual in-vehicle using conditions by the component manufacturer.
4.1.7 Ambient conditions in test cellAll tests shall be performed at an ambient temperature in the testcell of 25 ± 10 °C. The ambient temperature shall be measured within a distance of 1 m to the UUT.
4.1.8 Lubricating oil for IEPCs or IHPC Type 1Lubricating oil shall fulfill the provisions defined in points 4.1.8.1 to 4.1.8.4 below. These provisions shall not apply to EM systems.
4.1.8.1 Oil temperaturesThe oil temperatures shall be measured at the centre of the oil sump or at any other suitable point in accordance with good engineering practice. An auxiliary regulating system in accordance with paragraph 4.1.8.4 may be used, if necessary, to maintain the temperatures within the specified limits by the component manufacturer. In the case of external oil conditioning which is added for testing purposes only, the oil temperature may be measured in the outlet line from the housing of the UUT to the conditioning system within 5 cm downstream of the outlet. In both cases the oil temperature shall not exceed the temperature limit as specified by the component manufacturer. Solid engineering rationale shall be provided to the type approval authority to explain that the external oil conditioning system is not used to improve the efficiency of the UUT. For oil circuits which are neither part of, nor connected to the cooling circuit of any components of the electric machine system, the temperature shall not exceed 70 °C.
4.1.8.2 Oil qualityOnly recommended factory fill oils as specified by the component manufacturer of the UUT shall be used for the measurement.
4.1.8.3 Oil viscosityIf different oils are specified for the factory fill, the component manufacturer shall choose an oil for which the kinematic viscosity (KV) at the same temperature is within a range of ±10 % of the kinematic viscosity of the oil with the highest viscosity (within the specified tolerance band for KV100) for performing the measurements of the UUT related to certification.
4.1.8.4 Oil level and conditioningThe oil level or filling volume shall be within the maximum and minimum levels as defined in the component manufacturer’s maintenance specifications. An external oil conditioning and filtering system is permitted. The housing of the UUT may be modified for the inclusion of the oil conditioning system. The oil conditioning system shall not be installed in a way which would enable changing oil levels of the UUT in order to raise efficiency or to generate propulsion torques in accordance with good engineering practice.
4.1.9 Sign conventions
4.1.9.1 Torque and powerMeasured values of torque and power shall have a positive sign for the UUT driving the dyno and a negative sign for the UUT braking the dyno (i.e. dyno driving the UUT).
4.1.9.2 CurrentMeasured values of current shall have a positive sign for the UUT drawing electric power from the power supply to the inverter (or DC/DC converter if applicable) and a negative sign for the UUT delivering electric power to the inverter (or DC/DC converter if applicable) and to the power supply.
4.2 Test runs to be performedTable 2 defines all test runs to be performed for the purpose of certification of one specific electric machine system family or IEPC family defined in accordance with Appendix 13. The electric power mapping cycle (EPMC) in accordance with point 4.2.6 and the drag curve in accordance with point 4.2.3 shall be omitted for all other members within a family except the parent of the family. Where, upon request of the component manufacturer, Article 15(5) of this Regulation is applied, the EPMC in accordance with point 4.2.6 and the drag curve in accordance with point 4.2.3 shall be performed additionally for that specific EM or IEPC. Table 2 Overview of test runs to be performed for electric machine systems or IEPCs Test run | Reference to point | Required voltage level(s) to be performed (in accordance with 4.1.3) | Required to be run for parent | Required to be run for other members within a family Maximum and minimum torque limits | 4.2.2 | Vmin,Test and Vmax,Test | yes | yes Drag curve | 4.2.3 | Either Vmin,Test or Vmax,Test | yes | no Maximum 30 minutes continuous torque | 4.2.4 | Vmin,Test and Vmax,Test | yes | yes Overload characteristics | 4.2.5 | Vmin,Test and Vmax,Test | yes | yes EPMC | 4.2.6 | Vmin,Test and Vmax,Test | yes | no
4.2.1 General provisionsThe measurement shall be performed with all temperatures of the UUT during the test kept within the component manufacturer defined limit values. All tests need to be performed with de-rating functionality depending on temperature limits of the electric machine system fully active. Where additional parameters of other systems located outside of the electric machine system’s boundaries do influence the de-rating behaviour in in-vehicle applications, these additional parameters shall not be taken into account for all test runs performed in accordance with this Annex. For an electric machine system all torque and speed values indicated shall refer to the rotational shaft of the electric machine unless stated otherwise. For an IEPC all torque and speed values indicated shall refer to the output side of the gearbox or, if a differential is also included, to the output side of the differential unless stated otherwise.
4.2.2 Test of maximum and minimum torque limitsThe test measures the maximum and minimum torque characteristics of the UUT in order to verify the declared limitations of the system. For IEPC with multispeed gearbox the test shall be performed only for the gear with the gear ratio closest to 1. Where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios.
4.2.2.1 Declaration of values by the component manufacturerThe component manufacturer shall declare the values for the maximum and minimum torque of the UUT as a function of the rotational speed of the UUT between 0 rpm and the maximum operating speed of the UUT prior to the test. This declaration shall be separately made for each of the two voltage levels Vmin,Test and Vmax,Test.
4.2.2.2 Verification of maximum torque limitsThe UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 ± 10 °C for a minimum of two hours until the start of the test run. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of two hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ± 10 °C. Just before beginning the test, the UUT shall be run on the bench for three minutes delivering a power equal to 80 % of the maximum power at the speed recommended by the component manufacturer. The output torque and rotational speed of the UUT shall be measured at at least 10 different rotational speeds to define correctly the maximum torque curve between lowest and the highest speed. The lowest speed setpoint shall be specified by the component manufacturer at a speed equal or smaller than 2 % of the maximum operating speed of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1. Where the test setup does not allow operating the system at such a low speed setpoint, the lowest speed setpoint shall be specified by the component manufacturer as the lowest speed which can be realised by the specific test setup. The highest speed setpoint shall be defined by the maximum operating speed of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1. The remaining 8 or more different rotational speed setpoints shall be located between the lowest and highest speed setpoint and shall be specified by the component manufacturer. The interval between two adjacent speed setpoints shall not be larger than 15 % of the maximum operating speed of the UUT as declared by the component manufacturer. All operating points shall be held for an operating time of at least 3 seconds. Output torque and rotational speed of the UUT shall be recorded as average value of the last second of the measurement. The whole test shall be completed within 5 minutes.
4.2.2.3 Verification of minimum torque limitsThe UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 ±10 °C for a minimum of two hours until the start of the test run. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of two hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ±10 °C. Just before beginning the test, the UUT shall be run on the bench for three minutes delivering a power equal to 80 % of the maximum power at the speed recommended by the component manufacturer. The output torque and rotational speed of the UUT shall be measured at the same rotational speeds as selected in point 4.2.2.2. All operating points shall be held for an operating time of at least 3 seconds. Output torque and rotational speed of the UUT shall be recorded as average value of the last second of the measurement. The whole test shall be completed within 5 minutes.
4.2.2.4 Interpretation of resultsThe maximum torque of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1 shall be accepted as final values if they are not higher than + 2 % for overall maximum torque and than +4 % at the other measurement points with a tolerance of ± 2 % for rotational speeds from the values measured in accordance with point 4.2.2.2. Where the values for maximum torque declared by the component manufacturer exceed the limits defined above, the actual measured values shall be used as final values. Where the values for maximum torque of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1 are lower than the values measured in accordance with point 4.2.2.2, the values declared by the component manufacturer shall be used as final values. The minimum torque of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1 shall be accepted as final values if they are not lower than -2 % for overall minimum torque and than – 4% at the other measurement points with a tolerance of ±2 % for rotational speeds from the values measured in accordance with point 4.2.2.3. Where the values for minimum torque declared by the component manufacturer exceed the limits defined above, the actual measured values shall be used as final values. Where the values for minimum torque of the UUT as declared by the component manufacturer in accordance with point 4.2.2.1 are higher than the values measured in accordance with point 4.2.2.3, the values declared by the component manufacturer shall be used as final values.
4.2.3 Test of drag curveThe test measures the drag losses in the UUT, i.e. the mechanical and/or electrical power necessary to spin the system at a certain speed by external power sources. The UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 ±10 °C for a minimum of two hours. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of two hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ±10 °C. Just before beginning of the actual test, the UUT may optionally be run on the bench for three minutes delivering a power equal to 80 % of the maximum power at the speed recommended by the component manufacturer. The actual test shall be performed in accordance with one of the following options:
The test shall be performed at least at the same rotational speeds as selected in point 4.2.2.2, more operating points at other rotational speeds may be added. All operating points shall be held for an operating time of at least 10 seconds, during which the actual rotational speed of the UUT shall be within ± 2 % of the setpoint for rotational speed. The following values shall be recorded as average value over the last 5 seconds of the measurement, depending on the chosen testing option:
Changed in this versionWhere the UUT is an IEPC with multispeed gearbox, the test shall be performed for the gear with the gear ratio closest to 1. Where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios. Additionally, the test may be performed also for all other forward gears of the IEPC so that a dedicated dataset for each forward gear of the IEPC is determined.
Changed in this version4.2.4 Test of maximum 30 minutes continuous torqueThe test measures the maximum 30 minutes continuous torque which can be achieved by the UUT on average over a duration of 1 800 seconds. For IEPC with multispeed gearbox the test shall be performed only for the gear with the gear ratio closest to 1. Where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios.
4.2.4.1 Declaration of values by the component manufacturerThe component manufacturer shall declare the values for the maximum 30 minutes continuous torque of the UUT as well as the corresponding rotational speed prior to the test. The rotational speed shall be in a range, in which the mechanical power is greater than 90 % of the overall maximum power determined from the maximum torque limit data recorded in accordance with point 4.2.2 for the respective voltage level. This declaration shall be separately made for each of the two voltage levels Vmin,Test and Vmax,Test.
4.2.4.2 Verification of maximum 30 minutes continuous torqueThe UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 ±10 °C for a minimum of four hours. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of four hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ±10 °C. The UUT shall be run at the torque and speed setpoint which corresponds to the maximum 30 minutes continuous torque declared by the component manufacturer in accordance with point 4.2.4.1 for a total period of 1 800 seconds. The output torque and rotational speed of the UUT as well as the electric power to or from the inverter (or DC/DC converter if applicable) shall be measured over this period of 1 800 seconds. The mechanical power value measured over time shall be in a range of ±5 % of the mechanical power value declared by the component manufacturer in accordance with paragraph 4.2.4.1, the rotational speed shall be within ±2 % of the value declared by the component manufacturer in accordance with point 4.2.4.1. The maximum 30 minutes continuous torque is the average of the output torque within the 1 800 -second measurement period. The corresponding rotational speed is the average of the rotational speed within the 1 800 -second measurement period.
4.2.4.3 Interpretation of resultsThe values declared by the component manufacturer in accordance with point 4.2.4.1 shall be accepted as final values if they do not differ by more than +4 % for torque with a tolerance of ±2 % for rotational speed from the average values determined in accordance with point 4.2.4.2. Where the values declared by the component manufacturer exceed the limits defined above, the requirements referred to in points 4.2.4.1 to 4.2.4.3 shall be repeated with different values for the maximum 30 minutes continuous torque and/or the corresponding rotational speed. Where the value for torque declared by the component manufacturer in accordance with point 4.2.4.1 is lower than the average value for torque determined in accordance with point 4.2.4.2 with a tolerance of ±2 % for rotational speed, the values declared by the component manufacturer shall be used as final values. Additionally, the average of the actual measured electric power to or from the inverter (or DC/DC converter if applicable) over the 1 800 -second measurement period shall be calculated. Also the average 30 minutes continuous power shall be calculated from the final values of maximum 30 minutes continuous torque and the corresponding average rotational speed.
4.2.5 Test of overload characteristicsThe test measures the duration of the capability of the UUT to provide the maximum output torque in order to derive the overload characteristics of the system. For IEPC with multispeed gearbox the test shall be performed only for the gear with the gear ratio closest to 1. Where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios.
4.2.5.1 Declaration of values by the component manufacturerThe component manufacturer shall declare the value for the maximum output torque of the UUT at the specific rotational speed chosen for the test as well as the corresponding rotational speed prior to the test. The corresponding rotational speed shall be the same speed setpoint as used for the measurement performed in accordance with point 4.2.4.2 for the respective voltage level. The declared value for the maximum output torque of the UUT shall be equal or greater than the value of the maximum 30 minutes continuous torque determined in accordance with point 4.2.4.3 for the respective voltage level. In addition the component manufacturer shall declare a duration t0_maxP for which the maximum output torque of the UUT can be constantly achieved starting from the conditions as set out in point 4.2.5.2. This declaration shall be separately made for each of the two voltage levels Vmin,Test and Vmax,Test.
4.2.5.2 Verification of maximum output torqueThe UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 °C ± 10 °C for a minimum of two hours. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of two hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ±10 °C. Just before beginning the test, the UUT shall be run on the bench for 30 minutes delivering 50 % of the maximum 30 minutes continuous torque at the respective speed setpoint as determined in accordance with point 4.2.4.3. Then the UUT shall be run at the torque and speed setpoint which corresponds to the maximum output torque declared by the component manufacturer in accordance with point 4.2.5.1. The output torque and rotational speed of the UUT as well as the DC input voltage to the inverter (or DC/DC converter if applicable) and the electric power to or from the inverter (or DC/DC converter if applicable) shall be measured over a period of t0_maxP declared by the component manufacturer in accordance with point 4.2.5.1.
4.2.5.3 Interpretation of resultsThe recorded values for torque and speed over time measured in accordance with point 4.2.5.2 shall be accepted if they do not differ by more than ±2 % for torque and ±2 % for rotational speed from the values declared by the component manufacturer in accordance with point 4.2.5.1 over the whole period of t0_maxP. Where the values declared by the component manufacturer are outside the tolerances defined in the first paragraph of this point, the procedures laid down in points 4.2.5.1, 4.2.5.2 and in this point shall be repeated with different values for the maximum output torque of the UUT and/or the duration t0_maxP. The average of the actual measured values over the period of t0_maxP calculated for the different signals of rotational speed, torque and DC input voltage to the inverter (or DC/DC converter if applicable) shall be used as final values for characterisation of the overload point. Additionally, the average of the actual measured electric power to or from the inverter (or DC/DC converter if applicable) over the period of t0_maxP shall be calculated.
4.2.6 EPMC testThe EPMC test measures the electric power to or from the inverter (or DC/DC converter if applicable) for different operating points of the UUT.
4.2.6.1 PreconditioningThe UUT shall be conditioned (i.e. without operating the system) at an ambient temperature of 25 ±10 °C for a minimum of two hours. If this test is performed directly consecutive to any other test run performed in accordance with this Annex the conditioning for a minimum of two hours may be omitted or shortened as long as the UUT stays within the testcell with the ambient temperature in the testcell kept within 25 ±10 °C.
4.2.6.2 Operating points to be measuredFor IEPC with multispeed gearbox the setpoints for rotational speed in accordance with point 4.2.6.2.1 and for torque accordance with point 4.2.6.2.2 are determined for each single forward gear.
4.2.6.2.1 Setpoints for rotational speedThe setpoints for either a standalone electric machine system or an IEPC with no shiftable gears shall be defined in accordance with the following provisions:
As setpoints for rotational speed of the UUT the same setpoints used for the measurement performed in accordance with point 4.2.2.2 for the respective voltage level shall be used.
Changed in this versionThe speed setpoint for the maximum 30 minutes continuous torque verification performed in accordance with point 4.2.4.2 for the respective voltage level shall be used in addition to the setpoints defined in subpoint (a) above.
Changed in this versionFurther speed setpoints may be defined in addition to the setpoints defined in subpoints (a) and (b) above. In the case of an IEPC with multispeed gearbox, a separate dataset of setpoints for rotational speed of the UUT shall be defined for each single forward gear based on the following provisions:
Changed in this versionThe rotational speed setpoints for the gear with the gear ratio closest to 1 (where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios) determined in accordance with subpoints (a) to (c), nk,gear_iCT1, shall be used as basis for the further step in subpoint (e).
Changed in this versionThese rotational speed setpoints shall be converted to the respective setpoints for all other gears by the following equation: nk,gear = nk,gear_iCT1 × igear_iCT1 / igear where:
| nk,gear | = | rotational speed setpoint k for a specific gear |
(where k = 1, 2, 3, …, maximum number of rotational speed setpoints) (where gear = 1, …, highest gear number)
| nk,gear_iCT1 | = | rotational speed setpoint k for the gear with the gear ratio closest to 1 in accordance with subpoint (d) |
(where k = 1, 2, 3, …, maximum number of rotational speed setpoints)
| igear | = | gear ratio of a specific gear [-] |
(where gear = 1, …, highest gear number)
| igear_iCT1 | = | gear ratio of the gear with the gear ratio closest to 1 |
in accordance with subpoint (d) [-]
Changed in this version4.2.6.2.2 Setpoints for torqueThe setpoints for either a standalone electric machine system or an IEPC with no shiftable gears shall be defined in accordance with the following provisions:
At least 10 setpoints for torque of the UUT shall be defined for the measurement, located both on the positive (i.e. driving) and negative (i.e. braking) torque side. The lowest and highest torque setpoint shall be defined based on the minimum and maximum torque limits determined in accordance with point 4.2.2.4 for the respective voltage level, where the lowest torque setpoint shall be the overall minimum torque, Tmin_overall, and the highest torque setpoint shall be the overall maximum torque, Tmax_overall, determined from these values.
Changed in this versionThe remaining 8 or more different torque setpoints shall be located between the lowest and highest torque setpoint. The interval between two adjacent torque setpoints shall not be larger than 22.5 % of the overall maximum torque of the UUT determined in accordance with point 4.2.2.4 for the respective voltage level.
Changed in this versionThe limit value for positive torque at a particular rotational speed shall be the maximum torque limit at this particular rotational speed setpoint determined in accordance with point 4.2.2.4 for the respective voltage level, minus 5 % of Tmax_overall. All torque setpoints at a particular rotational speed setpoint that are located higher than the limit value for positive torque at this particular rotational speed shall be replaced by one single target torque setpoint located at the maximum torque limit at this particular rotational speed setpoint.
Changed in this versionThe limit value for negative torque at a particular rotational speed shall be the minimum torque limit at this particular rotational speed setpoint determined in accordance with point 4.2.2.4 for the respective voltage level, minus 5 % of Tmin_overall. All torque setpoints at a particular rotational speed setpoint that are located lower than the limit value for negative torque at this particular rotational speed shall be replaced by one single target torque setpoint located at the minimum torque limit at this particular rotational speed setpoint.
Changed in this versionMinimum and maximum torque limitations for a particular rotational speed setpoint shall be determined based on the data generated in accordance with point 4.2.2.4 for the respective voltage level, by using linear interpolation. In the case of an IEPC with multispeed gearbox, a separate dataset of setpoints for torque of the UUT shall be defined for each single gear based on the following provisions:
Changed in this versionThe torque setpoints for the gear with the gear ratio closest to 1 (where the gear ratios of two gears have the same distance to a gear ratio of 1, the test shall be performed only for the gear with the higher of the two gear ratios) determined in accordance with subpoints (a) to (e), Tj,gear_iCT1, shall be used as basis for the further step in subpoints (g) and (h).
Changed in this versionThese torque setpoints shall be converted to the respective setpoints for all other gears by the following equation: Tj,gear = Tj,gear_iCT1 / igear_iCT1 × igear where:
| Tj,gear | = | torque setpoint j for a specific gear |
(where j = 1, 2, 3, …, maximum number of torque setpoints) (where gear = 1, …, highest gear number)
| Tj,gear_iCT1 | = | torque setpoint j for the gear with the gear ratio closest to 1 |
in accordance with subpoint (f) (where j = 1, 2, 3, …, maximum number of torque setpoints)
| igear | = | gear ratio of a specific gear [-] |
(where gear = 1, …, highest gear number)
| igear_iCT1 | = | gear ratio of the gear with the gear ratio closest to 1 |
in accordance with subpoint (f) [-]
Changed in this versionAll torque setpoints Tj,gear that have an absolute value higher than 10 kNm shall not be required to be measured during the actual test run performed in accordance with point 4.2.6.4.
Changed in this version4.2.6.3 Signals to be measuredUnder the operating points specified in accordance with point 4.2.6.2 the electric power to or from the inverter (or DC/DC converter if applicable) and the output torque and speed of the UUT shall be measured.
4.2.6.4 Test sequenceThe test sequence consists of steady state setpoints with defined rotational speed and torque at each setpoint in accordance with point 4.2.6.2. In case an unforeseen interruption occurs, the test sequence may be continued under the following provisions:
In the case of an IEPC, the following provisions shall apply:
Changed in this versionJust before beginning the test at the first setpoint, the UUT shall be run on the bench for warm-up in accordance with the recommendations of the component manufacturer. The first rotational speed setpoint for the actual measured gear for starting the EPMC test is defined at the lowest rotational speed setpoint. The remaining setpoints for the actual measured gear shall be applied in the following order:
Changed in this versionThe first operating point at a particular rotational speed setpoint is defined at the highest torque at this specific speed.
Changed in this versionThe next operating point shall be set at the same speed and the lowest positive (i.e. driving) torque setpoint.
Changed in this versionThe next operating point shall be set at the same speed and the second highest positive (i.e. driving) torque setpoint.
Changed in this versionThe next operating point shall be set at the same speed and the second lowest positive (i.e. driving) torque setpoint.
Changed in this versionThis order of switching from the remaining highest to the remaining lowest torque setpoint shall be continued until all positive (i.e. driving) torque setpoints at a particular rotational speed setpoint are measured.
Changed in this versionBefore continuing with step (g) the UUT may be cooled down in accordance with the component manufacturer’s recommendations by running at a particular setpoint defined by the component manufacturer.
Changed in this versionThen measurement of the negative (i.e. braking) torque setpoints at the same rotational speed setpoint shall be performed starting at the lowest torque at this specific speed.
Changed in this versionThe next operating point shall be set at the same speed and the highest negative (i.e. braking) torque setpoint.
Changed in this versionThe next operating point shall be set at the same speed and the second lowest negative (i.e. braking) torque setpoint.
Changed in this versionThe next operating point shall be set at the same speed and the second highest negative (i.e. braking) torque setpoint.
Changed in this versionThis order of switching from the remaining lowest to the remaining highest torque setpoint shall be continued until all negative (i.e. braking) torque setpoints at a particular rotational speed setpoint are measured.
Changed in this versionBefore continuing with step (m) the UUT may be cooled down in accordance with the component manufacturer’s recommendations by running at a particular setpoint defined by the component manufacturer.
Changed in this versionThe test shall continue at the next higher rotational speed setpoint by repeating steps (a) to (m) of the defined test sequence above until all rotational speed setpoints for the actual measured gear were completed. All operating points shall be held for an operating time of at least 5 seconds. During this operating time the rotational speed of the UUT shall be held at the rotational speed setpoint within a tolerance of ±1 % or 20 rpm whatever is larger. Additionally, during this operating time, except for the highest and lowest torque setpoint at each rotational speed setpoint, the torque shall be held at the torque setpoint within a tolerance of ±1 % or ±5 Nm whatever is larger of the value of the torque setpoint. The electric power to or from the inverter (or DC/DC converter if applicable), the output torque and rotational speed of the UUT shall be recorded as average value over the last two seconds of the operating time.
Changed in this version4.3. Post-processing of measurement data of the UUT
4.3.1 General provisions for post-processingAll post-processing steps defined in points 4.3.2 to 4.3.6 shall be performed for the datasets measured for the two different voltage levels in accordance with point 4.1.3 separately.
4.3.2 Maximum and minimum torque limitsThe data for maximum and minimum torque limits determined in accordance with point 4.2.2.4 shall be extended by means of linear extrapolation (using the two closest points) to zero rotational speed and to the maximum operating speed of the UUT as declared by the component manufacturer in the event that the recorded measurement data does not cover these ranges.
4.3.3 Drag curveThe data for the drag curve determined in accordance with point 4.2.3 shall be modified in accordance with the following provisions:
Where the electric power supply to the inverter (or DC/DC converter if applicable) was set inactive or disconnected, the respective values for electric power to the inverter (or DC/DC converter if applicable) shall be set to 0.
Changed in this versionWhere the output shaft of the UUT was not connected to the load machine (i.e. dynamometer), the respective torque values shall be set to 0.
Changed in this versionThe data modified in accordance with points (1) and (2) above shall be extended by means of linear extrapolation to the maximum operating speed of the UUT as declared by the component manufacturer where the recorded measurement data does not cover these ranges.
Changed in this versionThe values of electric power to the inverter (or DC/DC converter if applicable) modified in accordance with points (1) to (3) above shall be seen as virtual mechanical loss power. These values of virtual mechanical loss power shall be converted to virtual drag torque with the respective rotational speed of the output shaft of the UUT.
Changed in this versionAt each setpoint of rotational speed of the output shaft of the UUT in the data modified in accordance with points (1) to (3) above, the value of virtual drag torque determined in accordance with point (4) above shall be added to the actual torque of the load machine (i.e. dynamometer) to define the total drag torque of the UUT as function of rotational speed.
Changed in this versionThe values of the total drag torque of the UUT at the lowest rotational speed setpoint, determined from the data modified in accordance with point (5) above, shall be copied to a new entry at 0 rpm rotational speed and added to the data modified in accordance with point (5) above.
Changed in this version4.3.4 EPMCThe data for the EPMC determined in accordance with point 4.2.6.4 shall be extended in accordance with the following provisions for each forward gear measured separately:
The values of all data pairs for output torque and eletric inverter power determined at the lowest rotational speed setpoint shall be copied to a new entry at zero rotational speed.
Changed in this versionThe values of all data pairs for output torque and eletric inverter power determined at the highest rotational speed setpoint shall be copied to a new entry at the highest rotational speed setpoint times 1.05.
Changed in this versionIf at a specific rotational speed setpoint (including the newly introduced data in points 1 and 2 above) a torque setpoint determined in accordance with the provisions of point 4.2.6.2.2 in subpoints (a) to (g) was ommited for the actual measurement in accordance with subpoint (h) of point 4.2.6.2.2 a new data point shall be calculated based on the following provisions:
Changed in this versionRotational speed: using the value of the omitted setpoint for the rotational speed
Changed in this versionTorque: using the value of the omitted setpoint for torque
Changed in this versionInverter power: calculating a new value by means of linear extrapolation where the slope of the least squares linear regression line determined based on the three actually measured torque points located closest to the torque value from subpoint (b) above for the corresponding rotational speed setpoint shall be applied.
Changed in this versionFor positive torque values, extrapolated values of inverter power resulting in values lower than the measured one at the actually measured torque point located closest to the torque value from subpoint (b) above shall be set to the inverter power actually measured at the torque point located closest to the torque value from subpoint (b) above.
Changed in this versionFor negative torque values, extrapolated values of inverter power resulting in values higher than the measured one at the actually measured torque point located closest to the torque value from subpoint (b) above shall be set to the inverter power actually measured at the torque point located closest to the torque value from subpoint (b) above.
Changed in this versionAt each rotational speed setpoint (including the newly introduced data in points 1 to 3 above) a new data point shall be calculated based on the data at the highest torque setpoint in accordance with the following rules:
Changed in this versionRotational speed: using the same value for the rotational speed
Changed in this versionTorque: using the value for torque multiplied by a factor of 1,05
Changed in this versionInverter power: calculating a new value in such a way that the efficiency defined as the ratio of mechanical power to inverter power stays constant
Changed in this versionAt each rotational speed setpoint (including the newly introduced data in points 1 to 3 above) a new data point shall be calculated based on the data at the lowest torque setpoint in accordance with the following rules:
Changed in this versionRotational speed: using the same value for the rotational speed
Changed in this versionTorque: using the value for torque multiplied by a factor of 1.05
Changed in this versionInverter power: calculating a new value in such a way that the efficiency defined as the ratio of inverter power to mechanical power stays constant
Changed in this version4.3.5 Overload characteristicsFrom the data for the overload characteristics determined in accordance with point 4.2.5.3 an efficiency figure shall be determined by dividing the average mechanical output power over the period of t0_maxP by the average electric power to or from the inverter (or DC/DC converter if applicable) over the period of t0_maxP.
4.3.6 Maximum 30 minutes continuous torqueFrom the data determined in accordance with point 4.2.4.3 an efficiency figure shall be determined by dividing the average 30 minutes continuous power by the average electric power to or from the inverter (or DC/DC converter if applicable). From the measurement data for the maximum 30 minutes continuous torque determined in accordance with point 4.2.4.2 the following average values shall be determined from the time-resolved values over the 1 800 -second measurement period for each cooling circuit with connection to an external heat exchanger separately:
The cooling power shall be determined based on the specific heat capacity of the coolant, the coolant massflow and the temperature difference over the test bed heat exchanger on the side of the UUT.
Changed in this version4.4 Special provisions for testing of IHPCs Type 1IHPCs Type 1 are virtually split into two separate components for handling in the simulation tool, i.e. an electric machine system and a transmission. Therefore, two separate component data sets shall be determined by following the provisions described in this point. For component testing of IHPCs Type 1, points 4.1 to 4.2 of this Annex shall apply. For an IHPC Type 1 the torque and speed shall be measured at the output shaft of the system (i.e. the output side of the gearbox towards the wheels of the vehicle). The definition of families in accordance with Appendix 13 shall not be allowed for IHPCs Type 1. Therefore, omission of test runs is not allowed and all test runs described in point 4.2 shall be performed for one specific IHPC Type 1. Notwithstanding these provisions, the test of the drag curve in accordance with point 4.2.3 shall be omitted for IHPCs Type 1. Generating input data for IHPCs Type 1 based on standard values shall not be allowed.
4.4.1 Test runs to be performed for IHPCs Type 1
4.4.1.1 Test runs to determine the total system characteristThis subpoint describes the details for determining the characteristics of the complete IHPC Type 1 including the losses of the gearbox part within the system. The following test runs shall be performed in accordance with the provisions defined for IEPC with multispeed gearbox in the respective points. For all of these test runs, the input shaft for feeding propulsion torque into the system shall be either disconnected and rotating freely or shall be fixed without rotating. Table 2a Overview of test runs to be performed for IHPC Type 1 Test run | Reference to point Maximum and minimum torque limits | 4.2.2 Maximum 30 minutes continuous torque | 4.2.4 Overload characteristics | 4.2.5 EPMC | 4.2.6 Due to the applicability of the provisions defined for IEPC with multispeed gearbox to IHPCs Type 1, the EPMC shall be measured for each single forward gear in accordance with point 4.2.6.2.
4.4.1.2 Test runs to determine the losses of the gearbox parThis subpoint describes the details for determining the losses of the gearbox part within the system. Therefore, the system shall be tested in accordance with the provisions in point 3.3 of Annex VI. Notwithstanding these provisions, the following provisions shall be applied:
4.4.2 Post-processing of measurement data of IHPCs Type 1For post-processing of measurement data of IHPCs Type 1, all provisions as laid down in point 4.3 shall apply unless stated otherwise.
4.4.2.1 Post-processing of data regarding total system charaAll measurement data determined in accordance with point 4.4.1.1 shall be handled in accordance with the provisions as laid down in points 4.3.1 to 4.3.6. The provisions of point 4.3.3 shall be omitted since measurement of the drag curve in accordance with point 4.2.3 is not performed for IHPCs Type 1. Where there are specific provisions defined for IEPC with multispeed gearbox in the respective points, such specific provisions shall be applied.
4.4.2.2 Post-processing of data regarding losses of the gearAll measurement data determined in accordance with point 4.4.1.2 shall be handled in accordance with the provisions as laid down in point 3.4 of Annex VI. Notwithstanding these provisions, the following provisions shall be applied:
4.4.2.3 Post-processing of data to derive the specific data In order to determine the component data of the virtual electric machine system the following steps shall be applied. The following post-processing steps shall be omitted for the two efficiency figures determined in accordance with points 4.3.5 and 4.3.6 since these efficiency figures only serve for assessment of conformity of the certified CO2 emissions and fuel consumption related properties.
All speed and torque values of the measurement data handled in accordance with point 4.4.2.1 shall be converted from the output shaft to the input shaft of the IHPC Type 1 in accordance with the following equations. Where the same test run was performed for several gears, the conversion shall be performed for each gear separately. where:
| nEM,virt | = | rotational speed of the virtual electric machine system referring to the input shaft of the IHPC Type 1 [1/min] |
|---|---|---|
| noutput | = | measured rotational speed at the output shaft of the IHPC Type 1 [1/min] |
| igbx | = | ratio of rotational speed at the input shaft over the rotational speed at the output shaft of the IHPC Type 1 for a specific gear engaged during the measurement [-] |
| TEM,virt | = | torque of the virtual electric machine system referring to the input shaft of the IHPC Type 1 [Nm] |
| Toutput | = | measured torque at the output shaft of the IHPC Type 1 [Nm] |
| Tloss,gbx | = | torque loss depending on rotational speed and torque at the input shaft of the IHPC Type 1 [Nm]. It shall be calculated by means of two-dimensional linear interpolation from the loss maps of the gearbox determined in accordance with point 4.4.2.2 for the respective gear. |
| gear | = | specific gear engaged during the measurement [-] |
The electric power maps determined for each forward gear in accordance with point 4.4.2.1 and converted to the input shaft in accordance with subpoint (a) of point 4.4.2.3 shall be used as basis for the following calculations. All values of electric inverter power of these electric power maps shall be converted to the respective maps for the virtual electric machine system by deducting the losses of the gearbox part in accordance with the following equation: where:
| Pel,virt | electric inverter power of the virtual electric machine system [W] |
|---|---|
| nEM,virt | rotational speed of the virtual electric machine system referring to the input shaft of the IHPC Type 1 determined in accordance with subpoint (a) of point 4.4.2.3 [1/min] |
| TEM,virt | torque of the virtual electric machine system referring to the input shaft of the IHPC Type 1 determined in accordance with subpoint (a) of point 4.4.2.3 [Nm] |
| Pel,meas | measured electric inverter power [W] |
| Tloss,gbx | torque loss depending on rotational speed and torque at the input shaft of the IHPC Type 1 [Nm]. It shall be calculated by means of two-dimensional linear interpolation from the loss maps of the gearbox determined in accordance with point 4.4.2.2 for the respective gear. |
| gear | specific gear engaged during the measurement [-] |
The drag torque values of the virtual electric machine system shall be specified at the same rotational speed setpoints, nEM,virt, referring to the input shaft of the IHPC Type 1 as used for the definition of the maximum and minimum torque curve of the virtual electric machine system. Each single value of drag torque in Nm indicated at the different rotational speed setpoints shall be set to zero.
Changed in this versionThe rotational inertia of the virtual electric machine system shall be calculated by converting the inertia value(s) of the actual electric machine(s) determined in accordance with point 8 of Appendix 8 of this Annex to the corresponding value of rotational inertia referring to the input shaft of the IHPC Type 1.
Changed in this version4.4.3 Generation of input data for the simulation toolSince IHPCs Type 1 are virtually split into two separate components for handling in the simulation tool, separate component input data shall be determined for an electric machine system and a transmission. The certification number indicated in the input data shall be the same for both components, electric machine system and transmission.
4.4.3.1 Input data of the virtual electric machine systemThe input data for the virtual electric machine system shall be generated in accordance with the definitions for the electric machine system in Appendix 15 based on the final data resulting from following the provisions in point 4.4.2.3.
4.4.3.2 Input data of the virtual transmissionThe input data for the virtual transmission shall be generated in accordance with the definitions for the transmission in Table 1 to Table 3 of Appendix 12 of Annex VI based on the final data resulting from following the provisions in point 4.4.2.2. The value of the parameter ‘TransmissionType’ in Table 1 shall be set to ‘IHPC Type 1’.
5. Testing of battery systems or representative battery subsThe battery UUT thermal conditioning device and the corresponding thermal conditioning loop at the test bench equipment shall be operational to satisfy the battery UUT thermal conditioning performances, according to the vehicle application and shall enable the test bench equipment to perform the requested test procedure within the battery UUT operational limits
5.1 General provisionsBattery UUT components may be distributed in different devices within the vehicle. The battery UUT shall be controlled by the BCU, the test bench equipment shall follow the operational limits provided by the BCU via bus communication. The battery UUT thermal conditioning device and the corresponding thermal conditioning loop at the test bench equipment shall be operational in accordance with the controls by the BCU, unless otherwise specified in the given test procedure. The BCU shall enable the test bench equipment to perform the requested test procedure within the battery UUT operational limits. If necessary, the BCU program shall be adapted by the component manufacturer for the requested test procedure but within the operational and safety limits of the battery UUT.
5.1.1 Conditions for thermal equilibrationThermal equilibration is reached if during a period of 1 hour the deviations between cell temperature as specified by the component manufacturer and temperature of all cell temperature measuring points are lower than ±7 K.
5.1.2 Sign conventions
5.1.2.1 CurrentMeasured values of current shall have a positive sign for discharging and a negative sign for charging.
5.1.3 Reference location for ambient temperatureThe ambient temperature shall be measured within a distance of 1 m to the battery UUT at a point indicated by the component manufacturer.
5.1.4 Thermal conditionsBattery testing temperature, i.e. the target operating temperature of the battery UUT, shall be specified by the component manufacturer. The temperature of all cell temperature measuring points shall be within the limits specified by the component manufacturer during all test runs performed. For battery UUT with liquid conditioning (i.e. heating or cooling), the temperature of the conditioning fluid shall be recorded at the battery UUT inlet and must be maintained within ±2 K of a value specified by the component manufacturer. For air cooled battery UUT, the temperature of the battery UUT at a point indicated by the component manufacturer shall be kept within +0/-20 K of the maximum value specified by the component manufacturer. For all test runs performed the available cooling and/or heating power on the testbench shall be limited to a value declared by the component manufacturer. This value shall be recorded together with the test data. The available cooling and/or heating power on the testbench shall be determined based on the following procedures and recorded together with the actual component test data:
For liquid conditioning from the massflow of the conditioning fluid and the temperature difference over the heat exchanger on the side of the battery UUT.
Changed in this versionFor electric conditioning from the voltage and current. The component manufacturer may modify the electric connection of this conditioning unit for the certification of the battery UUT to enable a measurement of the battery UUT characteristics without considering the electric power required for conditioning (e.g. if the conditioning is directly implemented and connected within the battery UUT). Notwithstanding these provisions, the required electric cooling and/or heating power externally provided to the battery UUT by a conditioning unit shall be recorded.
Changed in this versionFor other types of conditioning based on good engineering judgement and discussion with the type approval authority.
Changed in this version5.2 Preparation cyclesThe battery UUT shall be conditioned by performing maximum five cycles of full discharging followed by full charging in order to ensure stabilisation of the system’s performance before the actual testing starts. Consecutive cycles of full discharging followed by full charging shall be performed at the component manufacturer defined operational set temperature until the ‘preconditioned’ status is reached. The criterion for a ‘preconditioned’ battery UUT is that the discharged capacity during two consecutive discharges does not change by a value greater than 3 % of the rated capacity or that five repetitions were performed. The voltage of the battery UUT shall not fall below the minimum voltage recommended by the component manufacturer at the end of the discharge (the minimum voltage is the lowest voltage under discharge without irreversible damage done to the battery UUT). The termination criteria for the full discharging and the full charging cycles shall be defined by the component manufacturer.
5.2.1 Current levels in preparation cycles for HPBSDischarging shall be performed at a current of 2C, charging shall be performed in accordance with the recommendations of the component manufacturer.
5.2.2 Current levels in preparation cycles Preconditioning fDischarging shall be performed at a current of 1/3C, charging shall be performed in accordance with the recommendations of the component manufacturer.
5.3 Standard cycleThe purpose of a standard cycle (SC) is to ensure the same initial condition for each dedicated test of a battery UUT, as well as the charged energy for COP purposes in accordance with Appendix 12. It shall be performed at the component manufacturer defined operational set temperature.
5.3.1 Standard cycle for HPBSThe SC for HPBS shall consist of the following events in consecutive order: a standard discharge, a rest period, a standard charge and a second rest period. The standard discharge procedure shall be performed at a current of 1C down to the minimum SOC in accordance with the specifications of the component manufacturer. The rest period shall start directly after the end of discharge and shall last for 30 minutes. The standard charge procedure shall be performed in accordance with the specifications of the component manufacturer regarding criteria for end of charge as well as applicable time limits for the overall charging procedure. The second rest period shall start directly after the end of charge and shall last for 30 minutes.
5.3.2 Standard cycle for HEBSThe SC for HEBS shall consist of the following events in consecutive order: a standard discharge, a rest period, a standard charge and a second rest period. The standard discharge procedure shall be performed at a current of 1/3C down to the minimum SOC in accordance with the specifications of the component manufacturer. The rest period shall start directly after the end of discharge and shall last for 30 minutes. The standard charge procedure shall be performed in accordance with the specifications of the component manufacturer regarding criteria for end of charge as well as applicable time limits for the overall charging procedure. The second rest period shall start directly after the end of charge and shall last for 30 minutes.
5.4 Test runs to be performedBefore any test runs in accordance with this point are performed the battery UUT shall be subjected to the provisions in accordance with point 5.2.
5.4.1 Test procedure for rated capacityThis test measures the rated capacity of the battery UUT in Ah at constant current discharge rates.
5.4.1.1 Signals to be measuredThe following signals shall be recorded during preconditioning, standard cycles performed and the actual test run:
5.4.1.2 Test runAfter the battery UUT was fully charged in accordance with the specifications of the component manufacturer and thermal equilibration in accordance with point 5.1.1 was reached, a standard cycle in accordance with point 5.3 shall be performed. The actual test run shall start within a period of 3 hours after the end of the standard cycle, otherwise the standard cycle shall be repeated. The actual test run shall be performed at RT and consist of a constant current discharge at the following discharge rates:
All discharge tests shall be terminated at the minimum conditions in accordance with the specifications of the component manufacturer.
Changed in this version5.4.1.3 Interpretation of resultsThe capacity in Ah obtained from the integrated battery current over time during the actual test run in accordance with point 5.4.1.2 shall be used as value for the rated capacity.
5.4.1.4 Data to be reportedThe following data shall be reported:
For the purpose of conformity of production testing, also the following values shall be calculated:
Changed in this versionAll SOC values used shall be calculated based on the actual measured rated capacity determined in accordance with point 5.4.1.3. The round trip efficiency ηBAT shall be calculated by dividing the total discharged energy, Edis, by the total charged energy, Echa and reported in the information document in accordance with Appendix 5.
Changed in this version5.4.2 Test procedure for open circuit voltage, internal resiThis test determines the ohmic resistance for discharge and charge conditions as well as the OCV of the battery UUT as a function of SOC. In addition, the maximum current for discharging and charging as declared by the component manufacturer shall be verified.
5.4.2.1 General provisions for testingAll SOC values used shall be calculated based on the actual measured rated capacity determined in accordance with point 5.4.1.3. Only where the battery UUT reaches the discharge voltage limit during discharge, shall the current be reduced such that the battery UUT terminal voltage is maintained at the discharge voltage limit throughout the whole discharge pulse. Only where the battery UUT reaches during charging the charge voltage limit, shall the current be reduced such that the battery UUT terminal voltage is maintained at the charge voltage limit throughout the whole regenerative charge pulse. If the test equipment cannot provide the current value with the requested accuracy of ±1 % of the target value within 100 ms after a change in the current profile, the respective recorded data shall be discarded and no related values for open circuit voltage and internal resistance shall be calculated from this data. If the operational limits provided by the BCU via bus communication demand the current to be reduced in order to stay within the operational limits of the battery UUT the test bench equipment shall reduce the respective target current in accordance with the demands of the BCU.
5.4.2.2 Signals to be measuredThe following signals shall be recorded during preconditioning and the actual test run:
5.4.2.3 Test run
5.4.2.3.1 PreconditioningAfter the battery UUT was fully charged in accordance with the specifications of the component manufacturer and thermal equilibration in accordance with point 5.1.1 was reached, a standard cycle in accordance with point 5.3 shall be performed. Within a period of 1 to 3 hours after the end of the standard cycle, the actual test run shall be started. Otherwise, the procedure in the preceding paragraph shall be repeated.
5.4.2.3.2 Test procedureFor HPBS, the test shall be performed at five different SOC levels: 80, 65, 50, 35 and 20 %. For HEBS, the test shall be performed at five different SOC levels: 90, 70, 50, 35 and 20 %. At the last step at 20 % SOC the component manufacturer may reduce the maximum discharge current of the battery UUT in order for the SOC to stay above the minimum SOC, in accordance with the specifications of the component manufacturer and avoid a deep discharge. Before the beginning of the actual test runs at each SOC level, the battery UUT shall be preconditioned in accordance with point 5.4.2.3.1. In order to reach the required SOC levels for testing from the initial condition of the battery UUT, it shall be discharged at a constant current rate of 1C for HPBS and of 1/3C for HEBS followed by a rest period of 30 minutes before the next measurement starts. The component manufacturer shall prior to the test declare the maximum charge and discharge current at each different SOC level that can be applied throughout the length of the respective time increment of the current pulse defined in accordance with Table 3 for HPBS and Table 4 for HEBS. The actual test run shall be performed at RT and shall consist of the current profile in accordance with Table 3 for HPBS and in accordance with Table 4 for HEBS. Table 3 Current profile for HPBS Time increment [s] | Time cumulative [s] | Target current 0 | 0 | 0 20 | 20 | Idischg_max/33 40 | 60 | 0 20 | 80 | Ichg_max/33 40 | 120 | 0 20 | 140 | Idischg_max/32 40 | 180 | 0 20 | 200 | Ichg_max/32 40 | 240 | 0 20 | 260 | Idischg_max/3 40 | 300 | 0 20 | 320 | Ichg_max/3 40 | 360 | 0 20 | 380 | Idischg_max 40 | 420 | 0 20 | 440 | Ichg_max 40 | 480 | 0 Table 4 Current profile for HEBS Time increment [s] | Time cumulative [s] | Target current 0 | 0 | 0 120 | 120 | Idischg_max/33 40 | 160 | 0 120 | 280 | Ichg_max/33 40 | 320 | 0 120 | 440 | Idischg_max/32 40 | 480 | 0 120 | 600 | Ichg_max/32 40 | 640 | 0 120 | 760 | Idischg_max/3 40 | 800 | 0 120 | 920 | Ichg_max/3 40 | 960 | 0 120 | 1080 | Idischg_max 40 | 1120 | 0 120 | 1240 | Ichg_max 40 | 1280 | 0 Where Idischg_max | is the absolute value of the maximum discharge current specified by the component manufacturer at the specific SOC level that can be applied throughout the length of the respective time increment of the current pulse Ichg_max | is the absolute value of the maximum charge current specified by the component manufacturer at the specific SOC level that can be applied throughout the length of the respective time increment of the current pulse The voltage at time zero of the test run before the first change in target current occurs, i.e. V0, shall be measured as average value over 100 ms. For HPBS the following voltages and currents shall be measured:
For each different discharging and charging current pulse level specified in Table 3, the voltage under zero current as average value over the last second before the change in target current occurs, i.e. Vdstart for discharging and Vcstart for charging, shall be measured.
Changed in this versionFor each different discharging current pulse level specified in Table 3, the voltage at 2, 10 and 20 seconds after the change in target current occurs (Vd2, Vd10, Vd20) and the corresponding current (Id2, Id10, and Id20) shall be measured as average value over 100ms.
Changed in this versionFor each different charging current pulse level specified in Table 3, the voltage at 2, 10 and 20 seconds after the change in target current occurs (Vc2, Vc10, Vc20) and the corresponding current (Ic2, Ic10, and Ic20) shall be measured as average value over 100 ms. Table 5 gives an overview of voltage and current values to be measured over time after the change in target current occurs for HPBS. Table 5 Voltage measurement points for each different level of a current pulse (discharging and charging) for HPBS
| Time after the change in target current occurs [s] | Discharging (D) or charging (C) | Voltage | Current |
|---|---|---|---|
| 2 | D | Vd2 | Id2 |
| 10 | D | Vd10 | Id10 |
| 20 | D | Vd20 | Id20 |
| 2 | C | Vc2 | Ic2 |
| 10 | C | Vc10 | Ic10 |
| 20 | C | Vc20 | Ic20 |
For HEBS the following voltages and currents shall be measured:
Changed in this versionFor each different discharging and charging current pulse level specified in table 4 the voltage under zero current as average value over the last second before the change in target current occurs, i.e. Vdstart for discharging and Vcstart for charging, shall be measured.
Changed in this versionFor each different discharging current pulse level specified in table 4, the voltage at 2, 10 20 and 120 seconds after the change in target current occurs (Vd2, Vd10, Vd20 and Vd120) and the corresponding current (Id2, Id10, Id20 and Id120) shall be measured as average value over 100ms.
Changed in this versionFor each different charging current pulse level specified in table 4, the voltage at 2, 10, 20 and 120 seconds after the change in target current occurs (Vc2, Vc10, Vc20 and Vc120) and the corresponding current (Ic2, Ic10, Ic20 and Ic120) shall be measured as average value over 100 ms. Table 6 gives an overview of voltage and current values to be measured over the time after the change in target current occurs for HEBS. Table 6 Voltage measurement points for each different level of a current pulse (discharging and charging) for HEBS
| Time after the change in target current occurs [s] | Discharging (D) or charging (C) | Voltage | Current |
|---|---|---|---|
| 2 | D | Vd2 | Id2 |
| 10 | D | Vd10 | Id10 |
| 20 | D | Vd20 | Id20 |
| 120 | D | Vd120 | Id120 |
| 2 | C | Vc2 | Ic2 |
| 10 | C | Vc10 | Ic10 |
| 20 | C | Vc20 | Ic20 |
| 120 | C | Vc120 | Ic120 |
5.4.2.4 Interpretation of resultsThe following calculations shall be performed separately for each level of SOC measured in accordance with point 5.4.2.3.
5.4.2.4.1 Calculations for HPBS
For each different discharging current pulse level specified in Table 3, the values for internal resistance shall be calculated from the values of voltage and current measured in accordance with point 5.4.2.3 in accordance with the following equations:
Changed in this versionThe internal resistances for discharging RId2_avg, RId10_avg, RId20_avg shall be calculated as average over all different current pulse levels specified in Table 3 from the individual values calculated under point 1.
Changed in this versionFor each different charging current pulse level specified in Table 3, the values for internal resistance shall be calculated from the values of voltage and current measured in accordance with point 5.4.2.3 in accordance with the following equations:
Changed in this versionThe internal resistances for charging RIc2_avg, RIc10_avg, RIc20_avg shall be calculated as average over all different current pulse levels specified in Table 3 from the individual values calculated under point 3.
Changed in this versionThe overall internal resistances RI2, RI10 and RI20 shall be calculated as average over the respective values for discharging and charging calculated under points 2 and 4.
Changed in this versionThe open circuit voltage shall be the value of V0 measured in accordance with point 5.4.2.3 for the respective SOC level.
Changed in this versionThe limits for maximum discharging current shall be calculated as average value over 20 seconds at the target current Idischg_max for each level of SOC measured in accordance with point 5.4.2.3.
Changed in this versionThe limits for maximum charging current shall be calculated as average value over 20 seconds at the target current Ichg_max for each level of SOC measured in accordance with point 5.4.2.3. Absolute values of the results shall be reported as final values.
Changed in this version5.4.2.4.2 Calculations for HEBS
For each different discharging current pulse level specified in Table 4, the values for internal resistance shall be calculated from the values of voltage and current measured in accordance with point 5.4.2.3 in accordance with the following equations:
Changed in this versionThe internal resistances for discharging RId2_avg, RId10_avg, RId20_avg and RId120_avg shall be calculated as average over all different current pulse levels specified in Table 4 from the individual values calculated under point 1.
Changed in this versionFor each different charging current pulse level specified in Table 4, the values for internal resistance shall be calculated from the values of voltage and current measured in accordance with point 5.4.2.3 in accordance with the following equations:
Changed in this versionThe internal resistances for charging RIc2_avg, RIc10_avg, RIc20_avg and RIc120_avg shall be calculated as average over all different current pulse levels specified in Table 4 from the individual values calculated under point 3.
Changed in this versionThe overall internal resistances RI2, RI10, RI20 and RI120 shall be calculated as average over the respective values for discharging and charging calculated under points 2 and 4.
Changed in this versionThe open circuit voltage shall be the value of V0 measured in accordance with point 5.4.2.3 for the respective SOC level.
Changed in this versionThe limits for maximum discharging current shall be calculated as average value over 120 seconds at the target current Idischg_max for each level of SOC measured in accordance with point 5.4.2.3.
Changed in this versionThe limits for maximum charging current shall be calculated as average value over 120 seconds at the target current Ichg_max for each level of SOC measured in accordance with point 5.4.2.3. Absolute values of the results shall be reported as final values.
Changed in this version5.5. Post-processing of measurement data of the battery UUTThe values of OCV dependent on SOC shall be defined based on the values determined for the different SOC levels in accordance with point 6 of point 5.4.2.4.1 for HPBS and 5.4.2.4.2 for HEBS. The different values of internal resistances dependent on SOC shall be defined based on the values determined for the different SOC levels in accordance with point 5.4.2.4.1(5) for HPBS and 5.4.2.4.2 for HEBS. The limits for maximum discharging current and maximum charging current shall be defined based on the values as declared by the component manufacturer prior to the test. If a specific value for the maximum discharging current or maximum charging current determined in accordance with point 5.4.2.4.1(7) and (8) for HPBS and 5.4.2.4.2 for HEBS deviates by more than ±2 % from the value declared by the component manufacturer prior to the test, the respective value determined in accordance with points 5.4.2.4.1(7) and (8) for HPBS and 5.4.2.4.2 for HEBS shall be reported.
6. Testing of capacitor systems or representative capacitor
6.1 General provisionsCapacitor system components of the capacitor UUT may also be distributed in different devices within the vehicle. The characteristics for a capacitor are hardly dependent on its state of charge or current, respectively. Therefore, only a single test run is prescribed for the calculation of the model input parameters.
6.1.1 Sign convention for currentMeasured values of current shall have a positive sign for discharging and a negative sign for charging.
6.1.2 Reference location for ambient temperatureThe ambient temperature shall be measured within a distance of 1 m to the capacitor UUT at a point indicated by the component manufacturer of the capacitor UUT.
6.1.3 Thermal conditionsCapacitor testing temperature, i.e. the target operating temperature of the capacitor UUT, shall be specified by the component manufacturer. The temperature of all capacitor cell temperature measuring points shall be within the limits specified by the component manufacturer during all test runs performed. For capacitor UUT with liquid conditioning (i.e. heating or cooling), the temperature of the conditioning fluid shall be recorded at the capacitor UUT inlet and must be maintained within ±2 K of a value specified by the component manufacturer. For air cooled capacitor UUT, the temperature at a point indicated by the component manufacturer shall be kept within +0/–20 K of the maximum value specified by the component manufacturer. For all test runs performed the available cooling and/or heating power on the testbench shall be limited to a value declared by the component manufacturer. This value shall be recorded together with the test data. The available cooling and/or heating power on the testbench shall be determined based on the following procedures and recorded together with the actual component test data:
For liquid conditioning from the massflow of the conditioning fluid and the temperature difference over the heat exchanger on the side of the capacitor UUT.
Changed in this versionFor electric conditioning from the voltage and current. The component manufacturer may modify the electric connection of this conditioning unit for the certification of the capacitor UUT to enable a measurement of the capacitor UUT characteristics without considering the electric power required for conditioning (e.g. if the conditioning is directly implemented and connected within the capacitor UUT). Notwithstanding these provisions, the required electric cooling and/or heating power externally provided to the capacitor UUT by a conditioning unit shall be recorded.
Changed in this versionFor other types of conditioning based on good engineering judgement and discussion with the type approval authority.
Changed in this version6.2 Test conditions
The capacitor UUT shall be placed in a temperature controlled test cell. The ambient temperature shall be conditioned at 25 ±10 °C;
Changed in this versionThe voltage shall be measured at the terminals of the capacitor UUT.
Changed in this versionThe thermal conditioning system of the capacitor UUT and the corresponding thermal conditioning loop at the test bench equipment shall be fully operational in accordance with the respective controls.
Changed in this versionThe control unit shall enable the test bench equipment to perform the requested test procedure within the capacitor UUT operational limits. If necessary, the control unit program shall be adapted by the capacitor UUT component manufacturer for the requested test procedure.
Changed in this version6.3 Capacitor UUT characteristics test
After fully charging and then fully discharging the capacitor UUT to its lowest operating voltage in accordance with the charging method specified by the component manufacturer, it shall be soaked for at least 2 hours, but no more than 6 hours.
Changed in this versionThe capacitor UUT temperature at the start of the test shall be 25 ± 2 °C. However, 45 ± 2 °C may be selected by reporting to the type approval or certification authority that this temperature level is more representative for the conditions of the typical application.
Changed in this versionAfter the soak time, a complete charge and discharge cycle in accordance with Figure 2 with a constant current Itest shall be performed. Itest shall be the maximum allowed continuous current for the capacitor UUT as specified by the component manufacturer.
Changed in this versionAfter a waiting period of at least 30 seconds (t0 to t1), the capacitor UUT shall be charged with a constant current Itest until the maximum operating voltage V max is reached. Then, the charging shall be stopped and the capacitor UUT shall be soaked for 30 seconds (t2 to t3) so that the voltage can settle to its final value V b before the discharging is started. After that the capacitor UUT shall be discharged with a constant current Itest until the lowest operating voltage V min is reached. Afterwards (from t4 onwards) there shall be another waiting period of at least 30 seconds for the voltage to settle to its final value Vc.
Changed in this versionThe current and voltage over time, respectively Imeas and Vmeas, shall be recorded at a sampling frequency of at least 10 Hz.
Changed in this versionThe following characteristic values shall be determined from the measurement (illustrated in Figure 2):
Changed in this versionFigure 2
Example of voltage curve for the capacitor UUT measurement
6.4. Post-processing of measurement data of the capacitor UU
6.4.1 Calculation of internal resistance and capacitanceThe measurement data obtained in accordance with point 6.3 shall be used to calculate the internal resistance (R) and capacitance (C) values in accordance with the following equations:
The capacitance for charging and discharging shall be calculated as follows:
Changed in this versionThe maximum current for charging and discharging shall be calculated as follows:
Changed in this versionThe internal resistance for charging and discharging shall be calculated as follows:
Changed in this versionFor the model, only a single capacitance and resistance are needed and these shall be calculated as follows:
Changed in this versionThe maximum voltage shall be defined as the recorded value of Vb and the minimum voltage shall be defined as the recorded value of Vc as defined in accordance with subpoint (f) of point 6.3. Appendix 1
Changed in this versionMODEL OF A CERTIFICATE OF A COMPONENT, SEPARATE TECHNICAL UN
Maximum format: A4 (210 × 297 mm)
CERTIFICATE ON CO2 EMISSIONS AND FUEL CONSUMPTION RELATED PRAdministration stamp Communication concerning:
of a certificate on CO2 emission and fuel consumption related properties of an electric machine system / IEPC / IHPC Type 1 / battery system / capacitor system in accordance with Commission Regulation (EU) 2017/2400. Commission Regulation (EU) 2017/2400 as last amended by …………….. Certification number: Hash: Reason for extension:
Changed in this versionSECTION I0.1. Make (trade name of manufacturer): 0.2. Type: 0.3. Means of identification of type 0.3.1. Location of the certification marking: 0.3.2. Method of affixing certification marking: 0.5. Name and address of manufacturer: 0.6. Name(s) and address(es) of assembly plant(s): 0.7. Name and address of the manufacturer's representative (if any)
SECTION II1. Additional information (where applicable): see Addendum 2. Approval authority responsible for carrying out the tests: 3. Date of test report: 4. Number of test report: 5. Remarks (if any): see Addendum 6. Place: 7. Date: 8. Signature: Attachments: Information package. Test report. Appendix 2
Information Document for an electric machine systemInformation document no.: | Issue: Date of issue: Date of Amendment: pursuant to … Electric machine system type / family (if applicable): … 0. GENERAL 0.1. Name and address of manufacturer 0.2. Make (trade name of manufacturer): 0.3. Electric machine system type: 0.4. Electric machine system family: 0.5. Electric machine system type as separate technical unit / Electric machine system family as separate technical unit 0.6. Commercial name(s) (if available): 0.7. Means of identification of model, if marked on the Electric machine system: 0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark: 0.9. Name(s) and address(es) of assembly plant(s): 0.10. Name and address of the manufacturer's representative:
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) ELECTRIC MACHINE S|Parent EMS |Family members |or EMS type | | | #1 | #2 | #3 | 1. General 1.1. Test voltage(s): V 1.2. Basic motor rotational speed: 1/min 1.3. Motor output shaft maximum speed: 1/min 1.4. (or by default) reducer/gearbox outlet shaft speed: 1/min 1.5. Maximum power speed: 1/min 1.6. Maximum power: kW 1.7. Maximum torque speed: 1/min 1.8. Maximum torque: Nm 1.9. Maximum 30 minutes power: kW 2. Electric machine 2.1. Working principle 2.1.1. Direct current (DC)/alternating current (AC): 2.1.2. Number of phases: 2.1.3. Excitation / separate / series / compound: 2.1.4. Synchron / asynchron: 2.1.5. Rotor coiled / with permanent magnets / with housing: 2.1.6. Number of poles of the motor: 2.2. Rotational inertia: kgm2 3. Power controller 3.1. Make: 3.2. Type: 3.3. Working principle: 3.4. Control principle: vectorial / open loop / closed / other (t.b.s.): 3.5. Maximum effective current supplied to the motor: A 3.6. For maximum duration of: s 3.7. DC voltage range used (from / to): V 3.8. DC/DC converter is part of the electric machine system in accordance with paragraph 4.1 of this Annex (yes/no): 4. Cooling system 4.1. Motor (liquid / air / other t.b.s.): 4.2. Controller (liquid / air / other t.b.s.): 4.3. Description of the system: 4.4. Principle drawing(s): 4.5. Temperature boundary limits (min/max): K 4.6. At reference position: 4.7. Flow rates (min/max): ltr/min 5. Documented values from component testing 5.1. Efficiency figures for CoP ( 23 ): 5.2. Cooling system (declaration for each cooling circuit): 5.2.1. maximum coolant mass flow or volume flow or maximum inlet pressure: 5.2.2. maximum coolant temperatures: 5.2.3. maximum available cooling power: 5.2.4. Recorded average values for each test run 5.2.4.1. coolant volume flow or mass flow: 5.2.4.2. coolant temperature at the inlet of the cooling circuit: 5.2.4.3. coolant temperature at the inlet and outlet of the test bed heat exchanger on the side of the EMS:
LIST OF ATTACHMENTSNo.: | Description: | Date of issue: 1 | Information on EMS test conditions … 2 | …
Attachment 1 to Electric machine system information documentInformation on test conditions (if applicable) 1.1 | … Appendix 3
Information Document for an IEPCInformation document no.: | Issue: Date of issue: Date of Amendment: pursuant to …
IEPC type / family (if applicable):… 0. GENERAL 0.1. Name and address of manufacturer 0.2. Make (trade name of manufacturer): 0.3. IEPC type: 0.4. IEPC family: 0.5. IEPC type as separate technical unit / IEPC family as separate technical unit 0.6. Commercial name(s) (if available): 0.7. Means of identification of model, if marked on the IEPC: 0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark: 0.9. Name(s) and address(es) of assembly plant(s): 0.10. Name and address of the manufacturer's representative:
PART 1
ESSENTIAL CHARACTERISTICS OF THE (PARENT) IEPC AND THE IEPC |Parent IEPC |Family members |or IEPC type | | | #1 | #2 | #3 | 1. General 1.1. Test voltage(s): V 1.2. Basic motor rotational speed: 1/min 1.3. Motor output shaft maximum speed: 1/min 1.4. (or by default) reducer/gearbox outlet shaft speed: 1/min 1.5. Maximum power speed: 1/min 1.6. Maximum power: kW 1.7. Maximum torque speed: 1/min 1.8. Maximum torque: Nm 1.9. Maximum 30 minutes power: kW 1.10. Number of electric machines: 2. Electric machine (for each electric machine): 2.1. Electric machine ID: 2.2. Working principle 2.2.1. Direct current (DC)/alternating current (AC): 2.2.2. Number of phases: 2.2.3. Excitation / separate / series / compound: 2.2.4. Synchron / asynchron: 2.2.5. Rotor coiled / with permanent magnets / with housing: 2.2.6. Number of poles of the motor: 2.3. Rotational inertia: kgm2 3. Power controller (for each power controller): 3.1. Corresponding electric machine ID: 3.2. Make: 3.3. Type: 3.4. Working principle: 3.5. Control principle: vectorial / open loop / closed / other (t.b.s.): 3.6. Maximum effective current supplied to the motor: A 3.7. For maximum duration of: s 3.8. DC voltage range used (from / to): V 3.9. DC/DC converter is part of the electric machine system in accordance with paragraph 4.1 of this Annex (yes/no): 4. Cooling system 4.1. Motor (liquid / air / other t.b.s.): 4.2. Controller (liquid / air / other t.b.s.): 4.3. Description of the system: 4.4. Principle drawing(s): 4.5. Temperature boundary limits (min/max): K 4.6. At reference position: 4.7. Flow rates (min/max): g/min or ltr/min 5. Gearbox 5.1. Gear ratio, gearscheme and powerflow: 5.2. Center distance for countershaft transmissions: 5.3. Type of bearings at corresponding positions (if fitted): 5.4. Type of shift elements (tooth clutches, including synchronisers or friction clutches) at corresponding positions (where fitted): 5.5. Total number of forward gears: 5.6. Number of tooth shift clutches: 5.7. Number of synchronisers: 5.8. Number of friction clutch plates (except for single dry clutch with 1 or 2 plates): 5.9. Outer diameter of friction clutch plates (except for single dry clutch with 1 or 2 plates): 5.10. Surface roughness of the teeth (incl. drawings): 5.11. Number of dynamic shaft seals: 5.12. Oil flow for lubrication and cooling per transmission input shaft revolution 5.13. Oil viscosity at 100 C (± 10 %): 5.14. System pressure for hydraulically controlled gearboxes: 5.15. Specified oil level in reference to central axis and in accordance with the drawing specification (based on average value between lower and upper tolerance) in static or running condition. The oil level is considered as equal if all rotating transmission parts (except for the oil pump and the drive thereof) are located above the specified oil level: 5.16. Specified oil level (± 1mm): 5.17. Gear ratios [-] and maximum input torque [Nm], maximum input power (kW) and maximum input speed [rpm] (for each forward gear): 6. Differential 6.1. Gear ratio: 6.2. Principle technical specifications: 6.3. Principle drawings: 6.4. Oil volume: 6.5. Oil level: 6.6. Oil specification: 6.7. Bearing type (type, quantity, inner diameter, outer diameter, width and drawing): 6.8. Seal type (main diameter, lip quantity): 6.9. Wheel ends (drawing): 6.9.1. Bearing type (type, quantity, inner diameter, outer diameter, width and drawing): 6.9.2. Seal type (main diameter, lip quantity): 6.9.3. Grease type: 6.10. Number of planetary / spur gears for differential: 6.11. Smallest width of planetary/ spur gears for differential: 7. Documented values from component testing 7.1. Efficiency figures for CoP (*): 7.2. Cooling system (declaration for each cooling circuit): 7.2.1. maximum coolant mass flow or volume flow or maximum inlet pressure: 7.2.2. maximum coolant temperatures: 7.2.3. maximum available cooling power: 7.2.4. Recorded average values for each test run 7.2.4.1. coolant volume flow or mass flow: 7.2.4.2. coolant temperature at the inlet of the cooling circuit: 7.2.4.3. coolant temperature at the inlet and outlet of the test bed heat exchanger on the side of the IEPC:
LIST OF ATTACHMENTSNo.: | Description: | Date of issue: 1 | Information on IEPC test conditions … 2 | …
Attachment 1 to IEPC information document8. Information on test conditions (if applicable) 8.1. Maximum tested input speed [rpm] 8.2. Maximum tested input torque [Nm] Appendix 4
Information Document for an IHPC Type 1For IHPCs Type 1 the information document shall consist of the applicable parts of the information document for electric machine systems in accordance with Appendix 2 of this Annex and of the information document for transmissions in accordance with Appendix 2 of Annex VI. Appendix 5
Information Document for a battery system or a representativInformation document no.: | Issue: Date of issue: Date of Amendment: pursuant to … Battery system or representative battery subsystem type: … 0. GENERAL 0.1. Name and address of manufacturer 0.2. Make (trade name of manufacturer): 0.3. Battery system type: 0.4. - 0.5. Battery system type as separate technical unit 0.6. Commercial name(s) (if available): 0.7. Means of identification of model, if marked on the Battery system: 0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark: 0.9. Name(s) and address(es) of assembly plant(s): 0.10. Name and address of the manufacturer's representative:
PART 1
ESSENTIAL CHARACTERISTICS OF THE BATTERY SYSTEM OR THE REPRE
Battery (sub)system type1. General 1.1. Complete system or representative subsystem: 1.2. HPBS / HEBS: 1.3. Principle technical specifications: 1.4. Cell chemistry: 1.5. Number of cells in series: 1.6. Number of cells in parallel: 1.7. Representative junction box with fuses and breakers included in tested system (yes/no): 1.8. Representative serial connectors included in the tested system (yes/no): 2. Conditioning system 2.1. Liquid / air / other t.b.s.: 2.2. Description of the system: 2.3. Principle drawing(s): 2.4. Temperature boundary limits (min/max): K 2.5. At reference position: 2.6. Flow rates (min/max): ltr/min 3. Documented values from component testing 3.1. Round trip efficiency for CoP (**): 3.2. Maximum discharge current for CoP: 3.3. Maximum charge current for CoP: 3.4. Testing temperature (target operating temperature declared): 3.5. Conditioning system (indicate for each test run performed) 3.5.1. Cooling or heating required: 3.5.2. Maximum available cooling or heating power:
LIST OF ATTACHMENTSNo.: | Description: | Date of issue: 1 | Information on Battery system test conditions … 2 | …
Attachment 1 to Battery system information documentInformation on test conditions (if applicable) 1.1 | … Appendix 6
Information Document for a capacitor system or a representatInformation document no.: | Issue: Date of issue: Date of Amendment: pursuant to … Capacitor system or representative capacitor subsystem type: … 0. GENERAL 0.1. Name and address of manufacturer 0.2. Make (trade name of manufacturer): 0.3. Capacitor system type: 0.4. Capacitor system family: 0.5. Capacitor system type as separate technical unit / Capacitor system family as separate technical unit 0.6. Commercial name(s) (if available): 0.7. Means of identification of model, if marked on the Capacitor system: 0.8. In the case of components and separate technical units, location and method of affixing of the EC approval mark: 0.9. Name(s) and address(es) of assembly plant(s): 0.10. Name and address of the manufacturer's representative:
PART 1
ESSENTIAL CHARACTERISTICS OF THE CAPACITOR SYSTEM OR THE REP
Capacitor (sub)system type1. General 1.1. Complete system or representative subsystem: 1.2. Principle technical specifications: 1.3. Cell technology and specification: 1.4. Number of cells in series: 1.5. Number of cells in parallel: 1.6. Representative junction box with fuses and breakers included in tested system (yes/no): 1.7. Representative serial connectors included in the tested system (yes/no): 2. Conditioning system 2.1. Liquid / air / other t.b.s.: 2.2. Description of the system: 2.3. Principle drawing(s): 2.4. Temperature boundary limits (min/max): K 2.5. At reference position: 2.6. Flow rates (min/max): ltr/min 3. Documented values from component testing 3.1. Testing temperature (target operating temperature declared): 3.2. Conditioning system (indicate for each test run performed) 3.2.1. Cooling or heating required: 3.2.2. Maximum available cooling or heating power:
LIST OF ATTACHMENTSNo.: | Description: | Date of issue: 1 | Information on Capacitor system test conditions … 2 | …
Attachment 1 to Capacitor system information documentInformation on test conditions (if applicable) 1.1 | … Appendix 7 (reserved) Appendix 8
Standard values for electric machine systemThe following steps shall be performed to generate the input data for the electric machine system based on standard values:
A normalised power loss map shall be calculated as a function of normalised speed and torque values in accordance with the following equation: where:
| Ploss,norm | = | normalised loss power [–] |
|---|---|---|
| Tnorm,i | = | normalised torque for all gridpoints defined in accordance with subpoint (b)(ii) below [–] |
| ωnorm,j | = | normalised speed for all gridpoints defined in accordance with subpoint (b)(i) below [–] |
| k | = | loss coefficient [–] |
| m | = | index regarding torque dependent losses running from 0 to 3 [–] |
| n | = | index regarding speed dependent losses running from 0 to 3 [–] |
The normalised speed and torque values to be used for the equation in subpoint (a) above defining the grid points of the normalised loss map shall be:
Changed in this versionnormalised speed: 0,02, 0,20, 0,40, 0,60, 0,80, 1,00, 1,20, 1,40, 1,60, 1,80, 2,00, 2,20, 2,40, 2,60, 2,80, 3,00, 3,20, 3,40, 3,60, 3,80, 4,00 Where the highest rotational speed determined from the data generated in accordance with Step 2 above is located higher than a normalised speed value of 4,00, additional values of normalised speed with an increment of 0,2 shall be added to the existing list in order to cover the required speed range.
Changed in this versionnormalised torque: – 1,00, – 0,95, – 0,90, – 0,85, – 0,80, – 0,75, – 0,70, – 0,65, – 0,60, – 0,55, – 0,50, – 0,45, – 0,40, – 0,35, – 0,30, – 0,25, – 0,20, – 0,15, – 0,10, – 0,05, – 0,01, 0,01, 0,05, 0,10, 0,15, 0,20, 0,25, 0,30, 0,35, 0,40, 0,45, 0,50, 0,55, 0,60, 0,65, 0,70, 0,75, 0,80, 0,85, 0,90, 0,95, 1,00
Changed in this versionThe loss coefficient k to be used for the equation in subpoint (a) above shall be defined depending on the indices m and n in accordance with the following tables:
Changed in this versionIn the case of an electric machine of the type PSM: n
| 0 | 1 | 2 | 3 | ||
|---|---|---|---|---|---|
| m | 3 | 0 | 0 | 0 | 0 |
| 2 | 0,018 | 0,001 | 0,03 | 0 | |
| 1 | 0,0067 | 0 | 0 | 0 | |
| 0 | 0 | 0,005 | 0,0025 | 0,003 |
In the case of an electric machine of all other types except PSM: n
| 0 | 1 | 2 | 3 | ||
|---|---|---|---|---|---|
| m | 3 | 0 | 0 | 0 | 0 |
| 2 | 0,1 | 0,03 | 0,03 | 0 | |
| 1 | 0,01 | 0 | 0,001 | 0 | |
| 0 | 0,003 | 0 | 0,001 | 0,001 |
From the normalised power loss map determined in accordance with subpoints (a) to (c) above, the efficiency shall be calculated in accordance with the following provisions:
Changed in this versionThe grid points for the normalised speed shall be: 0,02, 0,20, 0,40, 0,60, 0,80, 1,00, 1,20, 1,40, 1,60, 1,80, 2,00, 2,20, 2,40, 2,60, 2,80, 3,00, 3,20, 3,40, 3,60, 3,80, 4,00 Where the highest rotational speed determined from the data generated in accordance with Step 2 above is located higher than a normalised speed value of 4,00, additional values of normalised speed with an increment of 0,2 shall be added to the existing list in order to cover the required speed range.
Changed in this versionThe grid points for the normalised torque shall be: – 1,00, – 0,95, – 0,90, – 0,85, – 0,80, – 0,75, – 0,70, – 0,65, – 0,60, – 0,55, – 0,50, – 0,45, – 0,40, – 0,35, – 0,30, – 0,25, – 0,20, – 0,15, – 0,10, – 0,05, – 0,01, 0,01, 0,05, 0,10, 0,15, 0,20, 0,25, 0,30, 0,35, 0,40, 0,45, 0,50, 0,55, 0,60, 0,65, 0,70, 0,75, 0,80, 0,85, 0,90, 0,95, 1,00
Changed in this versionFor each gridpoint defined in accordance with subpoints (d)(i) and (d)(ii) above the efficiency η shall be calculated in accordance with the following equations:
Changed in this version| η | = | efficiency [–] |
|---|---|---|
| Tnorm,i | = | normalised torque for all gridpoints defined in accordance with subpoint (d)(ii) above [–] |
| ωnorm,j | = | normalised speed for all gridpoints defined in accordance with subpoint (d)(i) above [–] |
| Ploss,norm | = | normalised loss power determined in accordance with subpoints (a) to (c) above [–] |
From the efficiency map determined in accordance with subpoint (d) above, the actual power loss map of the electric machine system shall be calculated in accordance with the following provisions:
Changed in this versionFor each gridpoint of normalised speed defined in accordance with subpoint (d)(i) above the actual speed values nj shall be calculated in accordance with the following equation: nj = ωnorm,j × nrated where:
| nj | = | actual speed [1/min] |
|---|---|---|
| ωnorm,j | = | normalised speed for all gridpoints defined in accordance with subpoint (d)(i) above [–] |
| nrated | = | rated speed of the electric machine system determined from the data generated in accordance with Step 2 above [1/min] |
For each gridpoint of normalised torque defined in accordance with subpoint (d)(ii) above the actual torque values Ti shall be calculated in accordance with the following equation: Ti = Tnorm,i × Tmax where:
| Ti | = | actual torque [Nm] |
|---|---|---|
| Tnorm,i | = | normalised torque for all gridpoints defined in accordance with subpoint (d)(ii) above [–] |
| Tmax | = | overall maximum torque of the electric machine system determined from the data generated in accordance with Step 2 above [Nm] |
For each gridpoint defined in accordance with subpoints (e)(i) and (e)(ii) above the actual power loss shall be calculated in accordance with the following equation: where:
| Ploss | = | actual loss power [W] |
|---|---|---|
| Ti | = | actual torque [Nm] |
| nj | = | actual speed [1/min] |
| η | = | efficiency dependent on normalised speed and torque determined in accordance with subpoint (d) above [–] |
| Tmax | = | overall maximum torque of the electric machine system determined from the data generated in accordance with Step 2 above [Nm] |
| nrated | = | rated speed of the electric machine system determined from the data generated in accordance with Step 2 above [1/min] |
For each gridpoint defined in accordance with subpoints (e)(i) and (e)(ii) above the actual electric inverter power shall be calculated in accordance with the following equation: where:
| Pel | = | actual electric inverter power [W] |
|---|---|---|
| Ploss | = | actual loss power [W] |
| Ti | = | actual torque [Nm] |
| nj | = | actual speed [1/min] |
The data of the actual electric power map determined in accordance with subpoint (e) above shall be extended in accordance with subpoints (1), (2), (4) and (5) of point 4.3.4 of this Annex.
Changed in this versionwhere:
| Tdrag | = | actual drag torque [Nm] |
|---|---|---|
| Ti | = | actual torque [Nm] |
| Tmax | = | overall maximum torque of the electric machine system determined from the data generated in accordance with Step 2 above [Nm] |
| nj | = | actual speed [1/min] |
| nrated | = | rated speed of the electric machine system determined from the data generated in accordance with Step 2 above [1/min] |
| Ploss | = | actual loss power [W] |
From the two values of drag torque determined in accordance with subpoint (a) above, a third value of drag torque at zero rotational speed shall be calculated by means of linear extrapolation.
Changed in this versionFrom the two values of drag torque determined in accordance with subpoint (a) above, a fourth value of drag torque at the maximum normalised speed value defined in accordance with subpoint (b)(i) of Step 6 above shall be calculated by means of linear extrapolation.
Changed in this versionOption 1: Based on the actual rotational inertia defined by the geometric form and the density of the respective materials of the rotor of the electric machine. Data and methods from a CAD software tool may be used to derive the actual rotational inertia of the rotor of the electric machine. The detailed method for determining the rotational inertia shall be agreed with the type approval authority.
Changed in this versionOption 2: Based on the outer dimensions of the rotor of the electric machine. A hollow cylinder shall be defined to fit the dimensions of the rotor of the electric machine in a way that:
Changed in this versionThe outer diameter of the cylinder matches the point of the rotor with the largest distance from the rotational axis of the rotor assessed along a straight line orthogonal to the rotational axis of the rotor.
Changed in this versionThe inner diameter of the cylinder matches the point of the rotor with the smallest distance from the rotational axis of the rotor assessed along a straight line orthogonal to the rotational axis of the rotor.
Changed in this versionThe length of the cylinder matches the distance between the two points located furthest from each other assessed along a straight line parallel to the rotational axis of the rotor. For the hollow cylinder defined in accordance with subpoints (i) to (iii) above the rotational inertia shall be calculated with a material density of 7 850 kg/m3. Appendix 9
Changed in this versionStandard values for IEPCIn order to allow using the provisions defined in this Appendix to generate input data for IEPC based fully or partially on standard values, the following conditions shall be fulfilled. Where more than one electric machine system is part of the IEPC, all electric machines shall have the exact same specifications. Where more than one electric machine system is part of the IEPC, all electric machines shall be connected to the torque path of the IEPC at the same reference position (i.e. either upstream of gearbox or downstream of gearbox) where all electric machines shall be run at the same rotational speed at this reference position and their individual torque (power) shall be added by any kind of summation gearbox. (1) One of the following options shall be used to generate the input data for IEPC, based fully or partially on standard values:
The standard values for the electric machine system as part of the IEPC shall be determined in accordance with Appendix 8. Where multiple electric machines are part of the IEPC, the standard values in accordance with Appendix 8 shall be determined for a single electric machine and all figures for torque and power (mechanical and electrical) shall be multiplied by the total number of electric machines being part of the IEPC. The resulting values from this multiplication shall be used for all further steps in this Appendix. The value for rotational inertia determined in accordance with Step 8 of Appendix 8 of this Annex shall be multiplied by the total number of electric machines being part of the IEPC.
Changed in this versionWhere a gearbox is included in the IEPC, the standard values for the IEPC shall be determined for each forward gear separately for the electric power consumption map, and only for the gear with the gear ratio closest to 1 for all other input data in accordance with the following procedure:
Changed in this versionThe standard values for losses in the gearbox shall be determined in accordance with point (2) of this Appendix.
Changed in this versionFor step number (i) above the rotational speed and torque points defined at the shaft of the electric machine system determined in accordance with subpoint (a) above shall be used as rotational speed and torque values at the input shaft of the gearbox.
Changed in this versionIn order to generate the required input data for IEPC in accordance with Appendix 15 referring to the output shaft of the gearbox, all torque values referring to the output shaft of the electric machine determined in accordance with subpoint (a) above shall be converted to the output shaft of the gearbox by the following equation: Ti,GBX = (Ti,EM – Ti,l,in (nj,EM, Ti,EM, gear)) × igear where:
| Ti,GBX | = | torque at output shaft of gearbox |
|---|---|---|
| Ti,EM | = | torque at output shaft of electric machine system |
| Ti,l,in | = | torque loss for each shiftable forward gear related to the input shaft of the gearbox parts of the IEPC determined in accordance with point (b)(i) above |
| nj,EM | = | Speed at the output shaft of electric machine system at which Ti,EM was measured [rpm] |
| igear | = | gear ratio of a specific gear [-] |
(where gear = 1, …, highest gear number)
Changed in this versionIn order to generate the required input data for IEPC in accordance with Appendix 15 referring to the output shaft of the gearbox, all speed values referring to the output shaft of the electric machine determined in accordance with subpoint (a) above shall be converted to the output shaft of the gearbox by the following equation: nj,GBX = nj,EM / igear where:
| nj,EM | = | Speed at the output shaft of electric machine [rpm] |
| igear | = | gear ratio of a specific gear [-] |
(where gear = 1, …, highest gear number)
Changed in this versionWhere a differential is included in the IEPC, the standard values for the differential shall be determined for each forward gear separately for the electric power consumption map and only for the for the gear with the gear ratio closest to 1 for all other input data in accordance with the following steps:
Changed in this versionThe standard values for losses in the differential shall be determined in accordance with point (3) of this Appendix.
Changed in this versionThe torque points defined at the output shaft of the gearbox being part of the IEPC determined in accordance with subpoint (b) above shall be used as torque values at the input of the differential. Where no gearbox is included in the IEPC, the torque points defined at the output shaft of the electric machine system determined in accordance with subpoint (a) above shall be used as torque values at the input of the differential for step number (i) above.
Changed in this versionIn order to generate the required input data for IEPC in accordance with Appendix 15 referring to the output of the differential, all torque values referring to the output shaft of either the gearbox (where a gearbox is included in the IEPC) determined in accordance with step number (iii) of subpoint (b) above or the electric machine system (in the case that no gearbox is included in the IEPC) determined in accordance with subpoint (a) above shall be converted to the output of the differential by the following equation: Ti,diff,out = (Ti,diff,in – Ti,diff,l,in (Ti,diff,in)) × idiff where:
| Ti,diff,out | = | torque at output of differential |
|---|---|---|
| Ti,diff,in | = | torque at input of differential |
| Ti,diff,l,in | = | torque loss related to the input of the differential dependent on the input torque determined in accordance with point (c)(i) above |
| idiff | = | differential gear ratio [-] |
In order to generate the required input data for IEPC in accordance with Appendix 15 referring to the output of the differential, all speed values referring to the output shaft of either the gearbox (where a gearbox is included in the IEPC) determined in accordance with step number (iv) of subpoint (b) above or the electric machine system (where no gearbox is included in the IEPC) determined in accordance with subpoint (a) above shall be converted to the output of the differential by the following equation: nj,diff,out = nj,diff,in / idiff where:
| nj,diff,in | = | speed at input of differential [rpm] |
| idiff | = | differential gear ratio [-] |
The measured component data for the electric machine system as part of the IEPC shall be determined in accordance with point 4 of this Annex. In the case of multiple electric machines being part of the IEPC, the component data shall be determined for a single electric machine and all figures for torque and power (mechanical and electrical) shall be multiplied by the total number of electric machines being part of the IEPC. The resulting values from this multiplication shall be used for all further steps in this Appendix. The value for rotational inertia determined in accordance with point 8 of Appendix 8 of this Annex shall be multiplied by the total number of electric machines being part of the IEPC.
Changed in this versionWhere a gearbox is included in the IEPC, the standard values for the IEPC shall be determined for each forward gear separately for the electric power consumption map and only for the gear with the gear ratio closest to 1 for all other input data in accordance with the provisions of Option 1(b) above. In this context all references in Option 1(b) to subpoint (a) shall be understood as references to subpoint (a) of Option 2.
Changed in this versionWhere a differential is included in the IEPC, the standard values for the differential shall be determined for each forward gear separately for the electric power consumption map and only for the gear with the gear ratio closest to 1 for all other input data in accordance with Option 1(c) above. In this context all references in Option 1(c) to subpoint (b) shall be understood as references to subpoint (b) of Option 2.
(2) IEPC internal component gearbox The torque loss Tgbx,l ,in for each shiftable forward gear related to the input shaft of the gearbox parts of the IEPC shall be calculated in accordance with the following provisions:
Tgbx,l,in (nin, Tin, gear) = Td0 + Td1000 × nin / 1000 rpm + fT,gear × Tin where:
| Tgbx,l,in | = | Torque loss related to the input shaft [Nm] |
|---|---|---|
| Tdx | = | Drag torque at x rpm [Nm] |
| nin | = | Speed at the input shaft [rpm] |
| fT,gear | = | Gear dependent torque loss coefficient [-]; |
determined acc. to subpoints (b)-(f) below
| Tin | = | Torque at the input shaft [Nm] |
| gear | = | 1, …, highest gear number [-] |
The values of the equation shall be determined for all transmission gears located downstream of the EM output shaft.
Changed in this versionWhere a differential is included in the IEPC, the values of the equation shall be determined for all transmission gears located downstream of the EM output shaft and upstream of, but excluding the gear mesh with the differential input gear. The gear mesh with the differential input gear can be an external-external gear mesh (either spur or bevel) or a single planetary gearset.
Changed in this versionIn the case of wheel hub motors, the values of the equation shall be determined for all transmission gears located downstream of the EM output shaft and upstream of the wheel hub.
Changed in this versionThe value for fT shall be determined in accordance with paragraph 3.1.1 of Annex VI.
Changed in this versionThe value for fT shall be 0,007 for a direct gear.
Changed in this versionThe values for Td0 and Td1000 shall be 0,0075 × Tmax,in for gearboxes with more than 2 friction shift clutches.
Changed in this versionThe values for Td0 and Td1000 shall be 0,0025 × Tmax,in for all other gearboxes.
Changed in this versionTmax,in shall be the overall maximum value of all individual maximum allowed input torque for each forward gear of the gearbox in [Nm].
(3) IEPC internal component differential The torque loss Tdiff,l ,in related to the input of the differential parts of the IEPC shall be calculated in accordance with the following provisions:
Tdiff,l,in (Tin) = ηdiff × Tdiff,d0 / idiff + (1- ηdiff) × Tin where:
| Tdiff,l,in | = | Torque loss related to the input of the differential [Nm] |
| Tdiff,d0 | = | Drag torque [Nm] |
determined acc. to subpoints (e)-(f) below
| ηdiff | = | Torque dependent efficiency [-]; |
determined acc. to subpoints (b)-(d) below
| Tin | = | Torque at the input of the differential [Nm] |
| idiff | = | differential gear ratio [-] |
The values of the equation shall be determined for all gear meshes of the differential including the gear mesh with the differential input gear.
Changed in this versionThe value for ηdiff shall be determined in accordance with paragraph 3.1.1 of Annex VI, where in the respective equations ηm shall be set to 0,98 in the case of a bevel gear mesh.
Changed in this versionThe losses in the differential internal gears are shall be ignored for the calculations performed in accordance with subpoints (b)-(c) above.
Changed in this versionIn the case of a differential that includes a bevel gear mesh at the differential crown gear, the value for Tdiff,d0 shall be determined based on the following equation: Tdiff,d0 = 25 Nm + 15 Nm × idiff
Changed in this versionIn the case of a differential that includes a spur gear mesh or single planetary gearset at the differential input gear, the value for Tdiff,d0 shall be determined based on the following equation: Tdiff,d0 = 25 Nm + 5 Nm × idiff Appendix 10
Changed in this versionStandard values for REESS(1) Battery system or representative battery subsystem The following steps shall be performed to generate the input data for the battery system or representative battery subsystem based on standard values:
The battery type shall be determined based on the numerical ratio between maximum current in A (as indicated in accordance with point 1.4.4 of Annex 6 – Appendix 2 of UN Regulation No. 100 (***) and capacity in Ah (as indicated in accordance with point 1.4.3 of Annex 6 – Appendix 2 of UN Regulation No. 100). The battery type shall be ‘high-energy battery system (HEBS)’ where this ratio is lower than 10 and shall be ‘high-power battery system (HPBS)’ where this ratio is equal to or higher than 10.
Changed in this versionThe rated capacity shall be the value in Ah as indicated in accordance with paragraph 1.4.3 of Annex 6 – Appendix 2 of UN Regulation No. 100.
Changed in this versionThe OCV as a function of SOC shall be determined based on the nominal voltage in V, Vnom, as indicated in accordance with paragraph 1.4.1 of Annex 6 – Appendix 2 of UN Regulation No. 100. The values of OCV for different levels of SOC shall be calculated in accordance with the following table:
| SOC [%] | OCV [V] |
|---|---|
| 0 | 0,88 × Vnom |
| 10 | 0,94 × Vnom |
| 50 | 1,00 × Vnom |
| 90 | 1,06 × Vnom |
| 100 | 1,12 × Vnom |
The DCIR shall be determined in accordance with the following provisions:
Changed in this versionFor HPBS in accordance with subpoint (a) above the DCIR shall be calculated by dividing the specific resistance of 25 [mOhm × Ah] by the rated capacity in Ah as defined in accordance with subpoint (b) above.
Changed in this versionFor HEBS in accordance with subpoint (a) above the DCIR shall be calculated by dividing the specific resistance of 140 [mOhm × Ah] by the rated capacity in Ah as defined in accordance with subpoint (b) above.
Changed in this versionThe values for maximum charging and maximum discharging current shall be determined in accordance with the following provisions:
Changed in this versionFor HPBS in accordance with subpoint (a) above the values for both, maximum charging and maximum discharging current, shall be set to the respective current in A corresponding to 10C.
Changed in this versionFor HEBS in accordance with subpoint (a) above the values for both, maximum charging and maximum discharging current, shall be set to the respective current in A corresponding to 1C. Absolute values for both, maximum charging and maximum discharging current, shall be used as final values.
(2) Capacitor system or representative capacitor subsystem The following steps shall be performed to generate the input data for the capacitor system or representative capacitor subsystem based on standard values:
The capacitance shall be the rated capacitance as indicated in the datasheet of the capacitor system or representative capacitor subsystem. The actual capacitance of the capacitor system or representative capacitor subsystem may be determined by scaling up the rated capacitance of a single capacitor cell in accordance with the arrangement (i.e. series and/or parallel) of the single cells in the capacitor system or representative capacitor subsystem.
Changed in this versionThe maximum voltage, Vmax,Cap, shall be the rated voltage as indicated in the datasheet of the capacitor system or representative capacitor subsystem. The actual maximum voltage of the capacitor system or representative capacitor subsystem may be determined by scaling up the rated voltage of a single capacitor cell in accordance with the arrangement (i.e. series and/or parallel) of the single cells in the capacitor system or representative capacitor subsystem.
Changed in this versionThe minimum voltage, Vmin,Cap, shall be the value of Vmax,Cap determined in accordance with subpoint (b) above multiplied by 0,45.
Changed in this versionThe internal resistance shall be determined in accordance with the following equation: where:
| RI,Cap | = | Internal resistance [Ohm] |
|---|---|---|
| RI,ref | = | Reference for internal resistance with a numeric value of 0,015 [Ohm] |
| Vmax,Cap | = | Maximum voltage as defined in accordance with subpoint (b) above [V] |
| Vmin,Cap | = | Minimum voltage as defined in accordance with subpoint (c) above [V] |
| Vref | = | Reference for maximum voltage with a numeric value of 2,7 [V] |
| Cref | = | Reference for capacitance with a numeric value of 3 000 [F] |
| CCap | = | Capacitance as defined in accordance with subpoint (a) above [F] |
The values for both, maximum charging and maximum discharging current, shall be calculated by multiplying the value of the capacitance in F as defined in accordance with subpoint (a) above by a factor of 5,0 [A/F]. Absolute values for both, maximum charging and maximum discharging current, shall be used as final values. Appendix 11 (reserved) Appendix 12
Changed in this versionConformity of the certified CO2 emissions and fuel consumpti
1. Electric machine systems or IEPCs1.1 Every electric machine system or IEPC shall be so manufactured as to conform to the approved type with regard to the description as given in the certificate and its annexes. The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out in Article 31 of Regulation (EU) 2018/858. 1.2 Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificates and information packages annexed thereto as set out in Appendices 2 and 3 of this Annex. 1.3 Conformity of the certified CO2 emissions and fuel consumption related properties shall be assessed in accordance with the specific conditions laid down in this paragraph. 1.4 The component manufacturer shall test annually at least the number of units indicated in Table 1 based on the total annual production number of electric machine systems or IEPCs produced by the component manufacturer. For the purpose of establishing the annual production numbers, only electric machine systems or IEPCs which fall under the requirements of this Regulation and for which no standard values were used shall be considered. 1.5 For total annual production volumes up to 4,000, the choice of the family for which the tests shall be performed shall be agreed between the component manufacturer and the approval authority. 1.6 For total annual production volumes above 4,000, the family with the highest production volume shall always be tested. The component manufacturer shall justify to the approval authority the number of tests which has been performed and the choice of the family. The remaining families for which the tests are to be performed shall be agreed between the manufacturer and the approval authority. Table 1 Sample size conformity testing Total annual production of either electric machine systems or IEPCs | Annual number of tests | Alternatively 0 – 1 000 | n.a. | 1 test every 3 years (*1) 1 001 – 2 000 | n.a. | 1 test every 2 years (*1) 2 001 – 4 000 | 1 | n.a. 4 001 – 10 000 | 2 | n.a. 10 001 – 20 000 | 3 | n.a. 20 001 – 30 000 | 4 | n.a. 30 001 – 40 000 | 5 | n.a. 40 001 – 50 000 | 6 | n.a. > 50 000 | 7 | n.a. (*1) The CoP test shall be performed in the first year 1.7. For the purpose of the conformity of the certified CO2 emissions and fuel consumption related properties testing the approval authority shall identify together with the component manufacturer the electric machine system or IEPC type(s) to be tested. The approval authority shall ensure that the selected electric machine system or IEPC type(s) is manufactured to the same standards as for serial production. 1.8 If the result of a test performed in accordance with point 1.9 is higher than the one specified in point 1.9.4, 3 additional units from the same family shall be tested. If any of them fails, Article 23 shall apply. 1.9 Production conformity testing of electric machine system or IEPC 1.9.1 Boundaries conditions All boundary conditions as specified in this Annex for the certification testing shall apply unless stated otherwise in this paragraph. The cooling power shall be within the limits as specified in this Annex for the certification testing. The measurement shall only be performed for one of the voltage levels indicated in paragraph 4.1.3 of this Annex. The voltage level for testing shall be chosen by the component manufacturer. The measurement equipment specifications defined in accordance with paragraph 3.1 of this Annex do not need to be fulfilled for CoP testing. 1.9.2 Test run Two different setpoints shall be measured. After the measurement at the first setpoint is completed, the system may be cooled down in accordance with the component manufacturer’s recommendations by running at a particular setpoint defined by the component manufacturer. For setpoint 1 the test of overload characteristics shall be performed in accordance with paragraph 4.2.5 of this Annex. For setpoint 2 the test of maximum 30 minutes continuous torque shall be performed in accordance with paragraph 4.2.4 of this Annex. 1.9.3 Post-processing of results All values of mechanical and electrical power determined in accordance with paragraphs 4.2.5.3 and 4.2.4.3 shall be corrected for uncertainty deviation of CoP measurement equipment in accordance with the following provisions:
The difference in measurement equipment uncertainty in % between component type approval and CoP testing in accordance with this Appendix shall be calculated for the measurement systems used for rotational speed, torque, current and voltage.
Changed in this versionThe difference in uncertainty in % referred to in subpoint (a) above shall be calculated for both, the analyser reading and the maximum calibration value defined in accordance with paragraph 3.1 of this Annex.
Changed in this versionThe total difference in uncertainty for electrical power shall be calculated based on the following equation: where:
| ΔuU,max calib | difference in uncertainty for maximum calibration value for voltage measurement [%] |
|---|---|
| ΔuU,value | difference in uncertainty for analyser reading for voltage measurement [%] |
| ΔuI,max calib | difference in uncertainty for maximum calibration value for current measurement [%] |
| ΔuI,value | difference in uncertainty for analyser reading for current measurement [%] |
The total difference in uncertainty for mechanical power shall be calculated based on the following equation: where:
| ΔuT,max calib | difference in uncertainty for maximum calibration value for torque measurement [%] |
|---|---|
| ΔuT,value | difference in uncertainty for analyser reading for torque measurement [%] |
| Δun,max calib | difference in uncertainty for maximum calibration value for rotational speed measurement [%] |
| Δun,value | difference in uncertainty for analyser reading for rotational speed measurement [%] |
All measured values of mechanical power shall be corrected based on the following equation: P* mech = Pmech,meas (1 – ΔuP,mech,CoP) where:
| Pmech,meas | measured value of mechanical power |
| ΔuP,mech,CoP | total difference in uncertainty for mechanical power in accordance with subpoint (d) above |
All measured values of electrical power shall be corrected based on the following equation: P* el = Pel,meas (1 + ΔuP,el,CoP) where:
| Pel,meas | measured value of electrical power |
| ΔuP,el,CoP | total difference in uncertainty for electrical power in accordance with subpoint (c) above |
1.9.4 Evaluation of results From the values for each of the two different setpoints determined in accordance with paragraphs 1.9.2 and 1.9.3, the efficiency figures shall be determined dividing the corrected mechanical power P* mech by the corrected electrical power P* el. The total efficiency during conformity of the certified CO2 emissions and fuel consumption related properties testing ηA,CoP shall be calculated by the arithmetic mean value of the two efficiency figures. The conformity of the certified CO2 emissions and fuel consumption related properties test is passed when the difference between ηA,CoP and ηA,TA is lower than 3 % of the type approved efficiency ηA,TA. In the case of an IEPC with either a gearbox or a differential included, the limit for passing the CoP test is raised to 4 % instead of 3. In the case of an IEPC with both a gearbox and a differential included, the limit for passing the CoP test is raised to 5 % instead of 3. The type approved efficiency ηA,TA shall be calculated by the arithmetic mean value of the two efficiency figures determined in accordance with paragraphs 4.3.5 and 4.3.6 and documented in the information document during component certification.
Changed in this version2. IHPCs Type 12.1 Every IHPC shall be so manufactured as to conform to the approved type with regard to the description as given in the certificate and its annexes. The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out in Article 31 of Regulation (EU) 2018/858. 2.2 Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificates and information packages annexed thereto as set out in Appendix 4 of this Annex. 2.3 Conformity of the certified CO2 emissions and fuel consumption related properties shall be assessed in accordance with the specific conditions laid down in paragraph 1 of this Appendix where the provisions defined for IEPC in the respective paragraphs shall be applied unless stated otherwise. 2.4 Notwithstanding the provisions in paragraph 2.3 of this Appendix, the following provisions shall be applied:
Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked only for individual types of IHPC Type 1 instead of families since definition of families is not allowed for IHPCs Type 1 in accordance with paragraph 4.4 of this Annex.
Changed in this versionThe allocation of the number of tests to be performed to a individual type shall be agreed between the manufacturer and the approval authority.
Changed in this versionAll references to families in the respective paragraphs shall be interpreted as references to individual types.
Changed in this versionThe type approved efficiency ηA,TA shall be calculated by the arithmetic mean value of the two efficiency figures determined in accordance with paragraphs 4.3.5 and 4.3.6 and recorded in the information document during component certification. For these two efficiency figures the post-processing steps described in paragraph 4.4.2.3 of this Annex shall not be performed.
Changed in this version3. Battery systems or representative battery subsystems3.1 Every battery system or representative battery subsystem shall be so manufactured as to conform to the approved type with regard to the description as given in the certificate and its annexes. The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out in Article 31 of Regulation (EU) 2018/858. 3.2 Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificates and information packages annexed thereto as set out in Appendix 5 of this Annex. 3.3 Conformity of the certified CO2 emissions and fuel consumption related properties shall be assessed in accordance with the specific conditions laid down in this paragraph. 3.4 The component manufacturer shall test annually at least the number of units indicated in Table 2 based on the total annual production number of battery systems or representative battery subsystems produced by the component manufacturer. For the purpose of establishing the annual production numbers, only battery systems or representative battery subsystems which fall under the requirements of this Regulation and for which no standard values were used shall be considered. Table 2 Sample size conformity testing Total annual production of battery systems or representative battery subsystems | Annual number of tests | Alternatively 0 – 3 000 | n.a. | 1 test every 3 years (*1) 3 001 – 6 000 | n.a. | 1 test every 2 years (*1) 6 001 – 12 000 | 1 | n.a. 12 001 – 30 000 | 2 | n.a. 30 001 – 60 000 | 3 | n.a. 60 001 – 90 000 | 4 | n.a. 90 001 – 120 000 | 5 | n.a. 120 001 – 150 000 | 6 | n.a. > 150 000 | 7 | n.a. (*1) The CoP test shall be performed in the first year 3.5. For the purpose of the conformity of the certified CO2 emissions and fuel consumption related properties testing the approval authority shall identify together with the component manufacturer the type(s) of battery system or representative battery subsystem to be tested. The approval authority shall ensure that the selected type(s) of battery system or representative battery subsystem is manufactured to the same standards as for serial production. 3.6 If the result of a test performed in accordance with point 3.7 is higher than the one specified in point 3.7.4., 3 additional units from the same type shall be tested. If any of them fails, Article 23 shall apply. 3.7 Production conformity testing of battery system or representative battery subsystem 3.7.1 Boundaries conditions All boundary conditions as specified in this Annex for the certification testing shall apply. 3.7.2 Test run Two different tests shall be performed. For test 1 the test procedure for rated capacity shall be performed in accordance with paragraph 5.4.1 of this Annex. For test 2 the following procedure shall be performed:
Test 2 shall be performed after test 1.
Changed in this versionAfter the battery UUT was fully charged in accordance with the specifications of the component manufacturer and thermal equilibration in accordance with paragraph 5.1.1 was reached, a standard cycle in accordance with paragraph 5.3 shall be performed.
Changed in this versionWithin a period of 1 to 3 hours after the end of the standard cycle, the actual test run shall be started. Otherwise, the procedure in the preceding subpoint (b) shall be repeated.
Changed in this versionIn order to reach the required SOC levels for testing as defined in subpoints (e) and (f) from the initial condition of the battery UUT, it shall be discharged at a constant current rate of 3C for HPBS and of 1C for HEBS.
Changed in this versionFor HPBS the actual test run shall consist of a 20-second discharge at 80 % SOC with the maximum discharge current Idischg_max as documented during component type approval and of a 20-second charge at 20 % SOC with the maximum charge current Ichg_max as documented during component type approval.
Changed in this versionFor HEBS the actual test run shall consist of a 120-second discharge at 90 % SOC with the maximum discharge current Idischg_max as documented during component type approval and of a 120-second charge at 20 % SOC with the maximum charge current Ichg_max as documented during component type approval.
Changed in this versionDuring the actual test run described in subpoints (e) and (f) above, the discharging and charging currents shall be recorded over the respective durations specified. 3.7.3 Post-processing of results For HPBS the discharging current at 80 % SOC and the charging current at 20 % SOC shall be averaged over the measurement period of 20 seconds. For HEBS the discharging current at 90 % SOC and the charging current at 20 % SOC shall be averaged over the measurement period of 120 seconds. Absolute numbers shall be used for both average values, discharging and charging current. 3.7.4 Evaluation of results The conformity of the certified CO2 emissions and fuel consumption related properties test is passed when all of the following criteria are fulfilled:
Changed in this versionCCoP ≥ 0,95 CTA where:
| CCoP | Rated capacity determined in accordance with paragraph 3.7.2 [Ah] |
| CTA | Rated capacity determined during component type approval [Ah] |
(ηBAT,CoP – ηBAT,TA) ≤ 3% where:
| ηBAT,CoP | Round trip efficiency determined in accordance with paragraph 3.7.2 [-] |
| ηBAT,TA | Round trip efficiency determined during component type approval [-] |
Idischg_max,CoP ≥ Idischg_max,TA where:
| Idischg_max,CoP | Maximum discharge current determined in accordance with paragraph 3.7.2 (at 80 % SOC for HPBS and at 90 % SOC for HEBS) [A] |
| Idischg_max,TA | Maximum discharge current determined during component type approval (at 80 % SOC for HPBS and at 90 % SOC for HEBS) [A] |
Ichg_max,CoP ≥ Ichg_max,TA where:
| Ichg_max,CoP | Maximum charge current determined in accordance with paragraph 3.7.2 (at 20 % SOC) [A] |
| Ichg_max,TA | Maximum charge current determined during component type approval (at 20 % SOC) [A] |
4. Capacitor systems4.1 Every capacitor systems shall be so manufactured as to conform to the approved type with regard to the description as given in the certificate and its annexes. The conformity of the certified CO2 emissions and fuel consumption related properties procedures shall comply with those set out in Article 31 of Regulation (EU) 2018/858. 4.2 Conformity of the certified CO2 emissions and fuel consumption related properties shall be checked on the basis of the description in the certificates and information packages annexed thereto as set out in Appendix 6 of this Annex. 4.3 Conformity of the certified CO2 emissions and fuel consumption related properties shall be assessed in accordance with the specific conditions laid down in this paragraph. 4.4 The component manufacturer shall test annually at least the number of units indicated in Table 3 based on the total annual production number of capacitor systems produced by the component manufacturer. For the purpose of establishing the annual production numbers, only capacitor systems which fall under the requirements of this Regulation and for which no standard values were used shall be considered. Table 3 Sample size conformity testing Total annual production of capacitor systems | Annual number of tests | Alternatively 0 – 3 000 | n.a. | 1 test every 3 years (*1) 3 001 – 6 000 | n.a. | 1 test every 2 years (*1) 6 001 – 12 000 | 1 | n.a. 12 001 – 30 000 | 2 | n.a. 30 001 – 60 000 | 3 | n.a. 60 001 – 90 000 | 4 | n.a. 90 001 – 120 000 | 5 | n.a. 120 001 – 150 000 | 6 | n.a. > 150 000 | 7 | n.a. (*1) The CoP test shall be performed in the first year 4.5. For the purpose of the conformity of the certified CO2 emissions and fuel consumption related properties testing the approval authority shall identify together with the component manufacturer the type(s) of capacitor systems to be tested. The approval authority shall ensure that the selected type(s) of capacitor systems is manufactured to the same standards as for serial production. 4.6 If the result of a test performed in accordance with point 4.7 is higher than the one specified in point 4.7.4., 3 additional units from the same type shall be tested. If any of them fails, Article 23 shall apply. 4.7 Production conformity testing of capacitor systems 4.7.1 Boundaries conditions All boundary conditions as specified in this Annex for the certification testing shall apply. 4.7.2 Test run The test procedure shall be performed in accordance with paragraph 6.3 of this Annex. 4.7.3 Post-processing of results The post-processing of results shall be performed in accordance with paragraph 6.4 of this Annex. 4.7.4 Evaluation of results The conformity of the certified CO2 emissions and fuel consumption related properties test is passed when all of the following criteria are fulfilled:
(CCoP / CTA) – 1 < ± 3 % where:
| CCoP | Capacitance determined in accordance with paragraph 4.7.2 [F] |
| CTA | Capacitance determined during component type approval [F] |
(RCoP / RTA) – 1 < ± 3 % where:
| RCoP | Internal resistance determined in accordance with paragraph 4.7.2 [Ohm] |
| RTA | Internal resistance determined during component type approval [Ohm] |
Appendix 13
Changed in this versionFamily concept
1. Electric machine systems and IEPCs
1.1. GeneralA family of electric machine systems or IEPCs is characterised by design and performance parameters. These shall be common to all members within the family. The component manufacturer may decide which electric machine systems or IEPCs belong to a family, as long as the membership criteria listed in this Appendix are respected. The related family shall be approved by the Approval Authority. The component manufacturer shall provide to the Approval Authority the appropriate information relating to the members of the family.
1.2. Special casesIn some cases there may be interaction between parameters. This shall be taken into consideration to ensure that electric machine systems or IEPCs with similar characteristics are included within the same family. These cases shall be identified by the component manufacturer and notified to the Approval Authority. It shall then be taken into account as a criterion for creating a new family of electric machine systems or IEPCs. In the case of devices or features, which are not listed in paragraph 1.4 and which have a strong influence on the level of performance and/or the electric power consumption, the respective devices or features shall be identified by the component manufacturer on the basis of good engineering practice, and shall be notified to the Approval Authority. It shall then be taken into account as a criterion for creating a new family of electric machine systems or IEPCs.
1.3. Family conceptThe family concept defines criteria and parameters enabling the component manufacturer to group electric machine systems or IEPCs into families with similar or equal data relevant for CO2-emissions or energy consumption.
1.4. Special provisions regarding representativenessThe Approval Authority may conclude that the performance parameters and the electric power consumption of the family of electric machine systems or IEPCs can best be characterised by additional testing. In this case, the component manufacturer shall submit the appropriate information to determine the electric machine system or IEPC within the family likely to best represent the family. The Approval Authority may based on this information also conclude that it is required for the component manufacturer to create a new family of electric machine systems or IEPCs consisting of less members in order to be more representative. If members within a family incorporate other features which may be considered to affect the performance parameters and/or the electric power consumption, these features shall also be identified and taken into account in the selection of the parent.
1.5. Parameters defining a family of electric machine systemIn addition to the parameters listed below, the component manufacturer may introduce additional criteria allowing the definition of families of more restricted size. These parameters are not necessarily parameters that have an influence on the level of performance and/or the electric power consumption. 1.5.1. The following criteria shall in principal be the same to all members within a family of electric machine systems or IEPCs:
Electric Machine: Rotor, Stator, Windings in dimensions, design, material, etc.
Changed in this versionInverter: Power Modules, Conductive bars in dimensions, design, material, etc.
Changed in this versionInternal cooling system: layout, dimension and material of cooling fins, ribs, and pins
Changed in this versionInternal fans: layout and dimension
Changed in this versionInverter Software: Basic calibration which consists of temperature models (electric machine and inverter), derating limits, torque path (transfer of command torque to phase current), flux calibration, current control, voltage modulation, sensor specific calibration (only allowed if sensor is changed)
Changed in this versionGear related parameters (only for IEPCs): in accordance with definitions set out in Annex VI. Changes to the components as mentioned at (a) through (f) are only acceptable as long as sound engineering rationale can be provided to prove that the respective change does not negatively affect the performance parameters and/or the electric power consumption. 1.5.2. The following criteria shall be common to all members within a family of electric machine systems or IEPCs. The application of a specific range to the parameters listed below is permitted after approval of the Approval Authority:
Changed in this versionOutput shaft interface: any changes allowed;
Changed in this versionEnd shields: For the internal design it must be checked if passive cooling elements or air flow at the inner side of the end shields are affected by changes. For the external design screws, suspension points, flange design have no influence on performance if no passive cooling elements are removed or changed;
Changed in this versionBearings: Changes allowed as long as number and type of bearings remain the same;
Changed in this versionShaft: Changes allowed as long as active or passive cooling is not affected;
Changed in this versionHigh voltage connection: Changes regarding position or type of the high voltage connection allowed;
Changed in this versionHousing: Changes of the housing or number, type and position of screws or mounting points allowed as long as no passive cooling elements are removed or changed;
Changed in this versionSensor: Changes allowed, if certified performance is not changed;
Changed in this versionInverter housing: Changes of the housing or number, type and position of screws or mounting points allowed as long as no passive cooling elements are removed or changed or the inner layout of the electric active parts is not changed;
Changed in this versionInverter high voltage connection: Changes regarding position or type of the high voltage connection allowed as long as the layout or position of the active parts or cooling elements (active/passive) is not changed;
Changed in this versionInverter software: All software changes which do not change the basic calibration of the electric machine (definition see above) are allowed. Notwithstanding the previous provisions, limitations of output power are allowed for members within a family of electric machine systems or IEPCs;
Changed in this versionInverter sensor: Changes allowed, if certified performance is not changed;
Changed in this versionOil viscosity: for all oils that are specified for the factory fill, the kinematic viscosity at the same temperature shall be less or equal to 110 % of the kinematic viscosity of the oil used for component certification as documented in the respective information document (within the specified tolerance band for KV100);
Changed in this versionMaximum torque curve The torque values at each rotational speed of the maximum torque curve of the parent determined in accordance with paragraph 4.2.2.4 of this Annex shall be equal or higher than for all other members within the same family at the same rotational speed over the whole rotational speed range. Torque values of other members within the same family within a tolerance of +40 Nm or +4 %, whatever is larger, above the maximum torque of the parent at a specific rotational speed are considered as equal;
Changed in this versionMinimum torque curve The torque values at each rotational speed of the minimum torque curve of the parent determined in accordance with paragraph 4.2.2.4 of this Annex shall be equal or lower than for all other members within the same family at the same rotational speed over the whole rotational speed range. Torque values of other members within the same family within a tolerance of -40 Nm or -4 %, whatever is larger, below the minimum torque of the parent at a specific rotational speed are considered as equal;
Changed in this versionMinimum number of points in the EPMC map: All members within the same family shall have a minimum coverage of 60 % of the points (rounded up to the next whole number) of the EPMC map (i.e. where the EPMC map of the parent is applied to other members) located within the boundaries of their respective maximum and minimum torque curves determined in accordance with paragraph 4.2.2.4 of this Annex.
Changed in this version1.6. Choice of the parentThe parent of one family of electric machine systems or IEPCs shall be member with the highest overall maximum torque determined in accordance with paragraph 4.2.2 of this Annex. Appendix 14
Markings and numbering
1. MarkingsIn the case of an electric powertrain component being type approved in accordance with this Annex, the component shall bear: 1.1. The manufacturer’s name or trade mark 1.2. The make and identifying type indication as recorded in the information referred to in paragraph 0.2 and 0.3 of Appendixes 2 to 6 of this Annex 1.3. The certification mark (if applicable) as a rectangle surrounding the lower-case letter ‘e’ followed by the distinguishing number of the Member State which has granted the certificate: 1 for Germany; | 19 for Romania; 2 for France; | 20 for Poland; 3 for Italy; | 21 for Portugal; 4 for the Netherlands; | 23 for Greece; 5 for Sweden; | 24 for Ireland; 6 for Belgium; | 25 for Croatia; 7 for Hungary; | 26 for Slovenia; 8 for Czechia; | 27 for Slovakia; 9 for Spain; | 29 for Estonia; 12 for Austria; | 32 for Latvia; 13 for Luxembourg; | 34 for Bulgaria; 17 for Finland; | 36 for Lithuania; 18 for Denmark; | 49 for Cyprus; 50 for Malta 1.4. The certification mark shall also include in the vicinity of the rectangle the ‘base certification number’ as specified for Section 4 of the type-approval number set out in Annex IV to Regulation (EU) 2020/683 preceded by the two figures indicating the sequence number assigned to the latest technical amendment to this Regulation and by an alphabetical character indicating the part for which the certificate has been granted: For this Regulation, the sequence number shall be 02. For this Regulation, the alphabetical character shall be the one laid down in Table 1. Table 1 M | electric machine system (EMS) I | integrated electric powertrain component (IEPC) H | integrated HEV powertrain component (IHPC) Type 1 B | battery system A | capacitor system 1.4.1. Example and dimensions of the certification mark The above certification mark affixed to an electric powertrain component shows that the type concerned has been approved in Austria (e12), pursuant to this Regulation. The first two digits (02) are indicating the sequence number assigned to the latest technical amendment to this Regulation. The following letter indicates that the certificate was granted for an electric machine system (M). The last five digits (00005) are those allocated by the type-approval authority to the electric machine system as the base certification number. 1.5 Upon request of the applicant for a certificate and after prior agreement with the type-approval authority other type sizes than indicated in 1.4.1 may be used. Those other type sizes shall remain clearly legible. 1.6 The markings, labels, plates or stickers must be durable for the useful life of the electric powertrain component and must be clearly legible and indelible. The manufacturer shall ensure that the markings, labels, plates or sticker cannot be removed without destroying or defacing them. 1.7 The certification mark shall be visible when the electric powertrain component is installed on the vehicle and shall be affixed to a part necessary for normal operation and not normally requiring replacement during component life.
2. Numbering:2.1. Certification number for an electric powertrain component shall comprise the following: eX*YYYY/YYYY*ZZZZ/ZZZZ*X*00000*00 section 1 | section 2 | section 3 | Additional letter to section 3 | section 4 | section 5 Indication of country issuing the certificate | HDV CO2 determination Regulation ‘2017/2400’ | Latest amending Regulation (ZZZZ/ZZZZ) | See Table 1 of this appendix | Base certification number 00000 | Extension 00 Appendix 15
Input parameters for the simulation tool
IntroductionThis Appendix describes the list of parameters to be provided by the component manufacturer as input to the simulation tool. The applicable XML schema as well as example data are available at the dedicated electronic distribution platform.
Definitions
‘parameter ID’: Unique identifier as used in the simulation tool for a specific input parameter or set of input data
Changed in this version‘type’: Data type of the parameter
| string… | sequence of characters in ISO8859-1 encoding |
|---|---|
| token… | sequence of characters in ISO8859-1 encoding, no leading/trailing whitespace |
| date… | date and time in UTC time in the format: YYYY-MM-DDTHH:MM:SSZ with italic letters denoting fixed characters e.g. ‘2002-05-30T09:30:10Z’ |
| integer… | value with an integral data type, no leading zeros, e.g. ‘1800’ |
| double, X… | fractional number with exactly X digits after the decimal sign (‘.’) and no leading zeros e.g. for ‘double, 2’: ‘2345,67’; for ‘double, 4’: ‘45,6780’ |
‘unit’ … physical unit of the parameter
Changed in this versionSet of input parameters for Electric machine systemTable 1 Input parameters ‘Electric machine system/General’ Parameter name | Parameter ID | Type | Unit | Description/Reference Manufacturer | P450 | token | [-] Model | P451 | token | [-] CertificationNumber | P452 | token | [-] Date | P453 | dateTime | [-] | Date and time when the component-hash is created AppVersion | P454 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data ElectricMachineType | P455 | string | [-] | Determined in accordance with point 21 of paragraph 2 of this Annex. Allowed values: ‘ASM’, ‘ESM’, ‘PSM’, ‘RM’ CertificationMethod | P456 | string | [-] | Allowed values: ‘Measurement’, ‘Standard values’ R85RatedPower | P457 | integer | [W] | Determined in accordance with paragraph 1.9 of Annex 2 to UN Regulation No. 85 Rev. 1 RotationalInertia | P458 | double, 2 | [kgm2] | Determined in accordance with point 8 of Appendix 8 of this Annex. DcDcConverterIncluded | P465 | boolean | [-] | Set to ‘true’ where a DC/DC converter is part of the electric machine system, in accordance with paragraph 4.1 of this Annex IHPCType | P466 | string | [-] | Allowed values: ‘None’, ‘IHPC Type 1’ Table 2 Input parameters ‘Electric machine system/VoltageLevels’ for each voltage level measured Parameter name | Parameter ID | Type | Unit | Description/Reference VoltageLevel | P467 | integer | [V] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, no input needs to be provided. ContinuousTorque | P459 | double, 2 | [Nm] TestSpeedContinuousTorque | P460 | double, 2 | [1/min] OverloadTorque | P461 | double, 2 | [Nm] TestSpeedOverloadTorque | P462 | double, 2 | [1/min] OverloadDuration | P463 | double, 2 | [s] Table 3 Input parameters ‘Electric machine system/MaxMinTorque’ for each operating point and for each voltage level measured Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P468 | double, 2 | [1/min] MaxTorque | P469 | double, 2 | [Nm] MinTorque | P470 | double, 2 | [Nm] Table 4 Input parameters ‘Electric machine system/DragTorque’ for each operating point Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P471 | double, 2 | [1/min] DragTorque | P472 | double, 2 | [Nm] Table 5 Input parameters ‘Electric machine system/ElectricPowerMap’ for each operating point and for each voltage level measured. In the case of an IHPC Type 1 (in accordance with the definition set out in sub point (42) of point 2 of this Annex), for each operating point, for each voltage level measured and for each forward gear. Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P473 | double, 2 | [1/min] Torque | P474 | double, 2 | [Nm] ElectricPower | P475 | double, 2 | [W] Table 6 Input parameters ‘Electric machine system/Conditioning’ for each cooling circuit with connection to an external heat exchanger Where the parameter ‘CertificationMethod’ is ‘Standard values’, no input needs to be provided. Parameter name | Parameter ID | Type | Unit | Description/Reference CoolantTempInlet | P476 | integer | [°C] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex. CoolingPower | P477 | integer | [W] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.
Set of input parameters for IEPCTable 1 Input parameters ‘IEPC/General’ Parameter name | Parameter ID | Type | Unit | Description/Reference Manufacturer | P478 | token | [-] Model | P479 | token | [-] CertificationNumber | P480 | token | [-] Date | P481 | dateTime | [-] | Date and time when the component-hash is created AppVersion | P482 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data ElectricMachineType | P483 | string | [-] | Determined in accordance with point 21 of paragraph 2 of this Annex. Allowed values: ‘ASM’, ‘ESM’, ‘PSM’, ‘RM’ CertificationMethod | P484 | string | [-] | Allowed values: ‘Measured for complete component’, ‘Measured for EM and standard values for other components’, ‘Standard values for all components’ R85RatedPower | P485 | integer | [W] | Determined in accordance with paragraph 1.9 of Annex 2 to UN Regulation No. 85 RotationalInertia | P486 | double, 2 | [kgm2] | Determined in accordance with point 8 of Appendix 8 of this Annex. DifferentialIncluded | P493 | boolean | [-] | Set to ‘true’ in the case a differential is part of the IEPC DesignTypeWheelMotor | P494 | boolean | [-] | Set to ‘true’ in the case of an IEPC design type wheel motor NrOf DesignTypeWheelMotorMeasured | P495 | integer | [-] | Input only relevant in the case of an IEPC design type wheel motor, in accordance with paragraph 4.1.1.2 of this Annex. Allowed values: ‘1’, ‘2’ Table 2 Input parameters ‘IEPC/Gears’ for each forward gear Parameter name | Parameter ID | Type | Unit | Description/Reference GearNumber | P496 | integer | [-] Ratio | P497 | double, 3 | [-] | Ratio of electric machine rotor speed over IEPC output shaft speed MaxOutputShaftTorque | P498 | integer | [Nm] | optional MaxOutputShaftSpeed | P499 | integer | [1/min] | optional Table 3 Input parameters ‘IEPC/VoltageLevels’ for each voltage level measured Parameter name | Parameter ID | Type | Unit | Description/Reference VoltageLevel | P500 | integer | [V] | Where the parameter ‘CertificationMethod’ is ‘Standard values for all components’, no input needs to be provided. ContinuousTorque | P487 | double, 2 | [Nm] TestSpeedContinuousTorque | P488 | double, 2 | [1/min] OverloadTorque | P489 | double, 2 | [Nm] TestSpeedOverloadTorque | P490 | double, 2 | [1/min] OverloadDuration | P491 | double, 2 | [s] Table 4 Input parameters ‘IEPC/MaxMinTorque’ for each operating point and for each voltage level measured Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P501 | double, 2 | [1/min] MaxTorque | P502 | double, 2 | [Nm] MinTorque | P503 | double, 2 | [Nm] Table 5 Input parameters ‘IEPC/DragTorque’ for each operating point and for each forward gear measured (optional gear dependent measurement in accordance with paragraph 4.2.3) Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P504 | double, 2 | [1/min] DragTorque | P505 | double, 2 | [Nm] Table 6 Input parameters ‘IEPC/ElectricPowerMap’ for each operating point, for each voltage level measured and for each forward gear Parameter name | Parameter ID | Type | Unit | Description/Reference OutputShaftSpeed | P506 | double, 2 | [1/min] Torque | P507 | double, 2 | [Nm] ElectricPower | P508 | double, 2 | [W] Table 7 Input parameters ‘IEPC/Conditioning’ for each cooling circuit with connection to an external heat exchanger Where the parameter ‘CertificationMethod’ is ‘Standard values for all components’, no input needs to be provided. Parameter name | Parameter ID | Type | Unit | Description/Reference CoolantTempInlet | P509 | integer | [°C] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex. CoolingPower | P510 | integer | [W] | Determined in accordance with paragraphs 4.1.5.1 and 4.3.6 of this Annex.
Set of input parameters for Battery systemTable 1 Input parameters ‘Battery system/General’ Parameter name | Parameter ID | Type | Unit | Description/Reference Manufacturer | P511 | token | [-] Model | P512 | token | [-] CertificationNumber | P513 | token | [-] Date | P514 | dateTime | [-] | Date and time when the component-hash is created AppVersion | P515 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data CertificationMethod | P517 | string | [-] | Allowed values: ‘Measured’, ‘Standard values’ BatteryType | P518 | string | [-] | Allowed values: ‘HPBS’, ‘HEBS’ RatedCapacity | P519 | double, 2 | [Ah] ConnectorsSubsystemsIncluded | P520 | boolean | [-] | Only relevant if representative battery sub-system is tested: Set to ‘true’ if representative cable harness for connecting battery sub-systems was included in testing. Always set to ‘true’ if complete battery system was tested. JunctionboxIncluded | P511 | boolean | [-] | Only relevant if representative battery sub-system is tested: Set to ‘true’ if representative junction box with shut-off device and fuses was included in testing. Always set to ‘true’ if complete battery system was tested. TestingTemperature | P521 | integer | [°C] | Determined in accordance with paragraph 5.1.4 of this Annex. Where the parameter ‘CertificationMethod’ is ‘Standard values’, no input needs to be provided. Table 2 Input parameters ‘Battery system/OCV’ for each SOC level measured Parameter name | Parameter ID | Type | Unit | Description/Reference SOC | P522 | integer | [%] OCV | P523 | double, 2 | [V] Table 3 Input parameters ‘Battery system/DCIR’ for each SOC level measured Parameter name | Parameter ID | Type | Unit | Description/Reference SOC | P524 | integer | [%] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, the same DCIR values shall be provided for two different SOC values of 0 % and 100 %. DCIR RI2 | P525 | double, 2 | [mOhm] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided. DCIR RI10 | P526 | double, 2 | [mOhm] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided. DCIR RI20 | P527 | double, 2 | [mOhm] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided. DCIR RI120 | P528 | double, 2 | [mOhm] | Optional, only required for batteries of type HEBS. In the event the parameter ‘CertificationMethod’ is ‘Standard values’, the DCIR value determined in accordance with subpoint (1)(d) of Appendix 10 shall be provided. Table 4 Input parameters ‘Battery system/Current limits’ for each SOC level measured Parameter name | Parameter ID | Type | Unit | Description/Reference SOC | P529 | integer | [%] | Where the parameter ‘CertificationMethod’ is ‘Standard values’, the same values for MaxChargingCurrent as well as MaxDischargingCurrent shall be provided for two different SOC values of 0 % and 100 %. MaxChargingCurrent | P530 | double, 2 | [A] MaxDischargingCurrent | P531 | double, 2 | [A]
Set of input parameters for Capacitor systemTable 1 Input parameters ‘Capacitor system/General’ Parameter name | Parameter ID | Type | Unit | Description/Reference Manufacturer | P532 | token | [-] Model | P533 | token | [-] CertificationNumber | P534 | token | [-] Date | P535 | dateTime | [-] | Date and time when the component-hash is created AppVersion | P536 | token | [-] | Manufacturer specific input regarding the tools used for evaluation and handling of measured component data CertificationMethod | P538 | string | [-] | Allowed values: ‘Measurement’, ‘Standard values’ Capacitance | P539 | double, 2 | [F] InternalResistance | P540 | double, 2 | [Ohm] MinVoltage | P541 | double, 2 | [V] MaxVoltage | P542 | double, 2 | [V] MaxChargingCurrent | P543 | double, 2 | [A] MaxDischargingCurrent | P544 | double, 2 | [A] TestingTemperature | P532 | integer | [°C] | Determined in accordance with paragraph 6.1.3 of this Annex. Where the parameter ‘CertificationMethod’ is ‘Standard values’, no input needs to be provided. (*) determined in accordance with points 4.3.5 and 4.3.6 of this Annex (**) determined in accordance with points 5.4.1.4 of this Annex (***) UN Regulation No. 100 of the Economic Commission for Europe of the United Nations (UNECE) — Uniform provisions concerning the approval of vehicles with regard to specific requirements for the electric powertrain (OJ L449, 15.12.2021 p. 1).
ANNEX XI
AMENDMENTS TO DIRECTIVE 2007/46/EC
the row 41A is replaced by the following:
| ‘41A | Emissions (Euro VI) heavy duty vehicles/access to information | Regulation (EC) No 595/2009 | ||||
| Regulation (EU) No 582/2011 | X (9) | X (9) | X | X (9) | X (9) | X’ |
the following row 41B is inserted:
| ‘41B | CO2 simulation tool licence (heavy-duty vehicles) | Regulation (EC) 595/2009 |
| Regulation (EU) 2017/2400 | X (16) | X’ |
the following explanatory note 16 is added: ‘(16) For vehicles with a technically permissible maximum laden mass from 7 500 kg’
(4) Annex IX is amended as follows:
in Part I, Model B, SIDE 2, VEHICLE CATEGORY N2, the following point 49 is inserted: ‘49. Cryptographic hash of the manufacturer's record file …’
Changed in this versionin Part I, Model B, SIDE 2, VEHICLE CATEGORY N3, the following point 49 is inserted: ‘49. Cryptographic hash of the manufacturer's record file …’
(5) in Annex XV, in point 2, the following row is inserted:
| ‘46B | Rolling resistance determination | Regulation (EU) 2017/2400, Annex X’ |
( 1 ) Regulation (EU) 2018/858 of the European Parliament and of the Council of 30 May 2018 on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles, amending Regulations (EC) No 715/2007 and (EC) No 595/2009 and repealing Directive 2007/46/EC (OJ L 151, 14.6.2018, p. 1). ( *1 ) Commission Regulation (EU) 2017/2400 of 12 December 2017 implementing Regulation (EC) No 595/2009 of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles and amending Directive 2007/46/EC of the European Parliament and of the Council and Commission Regulation (EU) No 582/2011 (OJ L 349, 29.12.2017, p. 1).’; ( 2 ) UN Regulation No. 107 of the Economic Commission for Europe of the United Nations (UNECE) – Uniform provisions concerning the approval of category M2 or M3 vehicles with regard to their general construction (OJ L 52, 23.2.2018, p. 1). ( 3 ) Commission Implementing Regulation (EU) 2020/683 of 15 April 2020 implementing Regulation (EU) 2018/858 of the European Parliament and of the Council with regards to the administrative requirements for the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles (OJ L 163, 26.5.2020, p. 1). ( 4 ) Input information and input data as defined in Annex III for primary vehicles. ( 5 ) The results for CO2 emissions and fuel consumption do not need to be submitted via the VIF, as this information can be calculated from results for energy consumption and the known fuel type. ( 6 ) The content of the VIF is specified in detail in Annex IV, Part III. ( 7 ) Subset for input information and input data as defined in Annex III for complete and completed vehicles. ( 8 ) ‘i’ represents the number of manufacturing steps involved in the process so far. ( 9 ) See Annex IV, Part III, point 1.1. ( 10 ) OJ L 349, 29.12.2017, p. 1. ( 11 ) Regulation No. 49 of the Economic Commission for Europe of the United Nations (UN/ECE) – Uniform provisions concerning the measures to be taken against the emission of gaseous and particulate pollutants from compression-ignition engines and positive ignition engines for use in vehicles (OJ L 171, 24.6.2013, p. 1). ( 12 ) For dual-fuel engines indicate values for each fuel type and each operation mode separately; ►M3
( 13 ) Specify the tolerance; to be within ± 3 % of the values declared by the manufacturer. ◄ ( 14 ) Regulation No 85 of the Economic Commission for Europe of the United Nations (UN/ECE) – Uniform provisions concerning the approval of internal combustion engines or electric drive trains intended for the propulsion of motor vehicles of categories M and N with regard to the measurement of net power and the maximum 30 minutes power of electric drive trains (OJ L 323, 7.11.2014, p. 52) ( 15 ) Delete where not applicable (there are cases where nothing needs to be deleted when more than one entry is applicable) ( 16 ) Regulation No 54 of the Economic Commission for Europe of the United Nations (UNECE) – Uniform provisions concerning the approval of pneumatic tyres for commercial vehicles and their trailers (OJ L 183, 11.7.2008, p. 41). ( *2 ) Regulation No 107 of the Economic Commission for Europe of the United Nations (UNECE) – Uniform provisions concerning the approval of category M2 or M3 vehicles with regard to their general construction (OJ L 52, 23.2.2018, p. 1). ( *3 ) Regulation No 48 of the Economic Commission for Europe of the United Nations (UNECE) – Uniform provisions concerning the approval of vehicles with regard to the installation of lighting and light-signalling devices (OJ L 14, 16.1.2019, p. 42). ( *4 ) Regulation No 122 of the Economic Commission for Europe of the United Nations (UN/ECE) – Uniform technical prescriptions concerning the approval of vehicles of categories M, N and O with regard to their heating systems (OJ L 19, 24.1.2020, p. 42). ( 17 ) Regulation No 54 of the Economic Commission for Europe of the United Nations (UNECE) — Uniform provisions concerning the approval of pneumatic tyres for commercial vehicles and their trailers (OJ L 183, 11.7.2008, p. 41). ( 18 ) Regulation No 117 of the Economic Commission for Europe of the United Nations (UNECE) — Uniform provisions concerning the approval of tyres with regard to rolling sound emissions and/or to adhesion on wet surfaces and/or to rolling resistance [2016/1350] (OJ L 218, 12.8.2016, p. 1). ( 19 ) Regulation (EU) 2020/740 of the European Parliament and of the Council of 25 May 2020 on the labelling of tyres with respect to fuel efficiency and other parameters, amending Regulation (EU) 2017/1369 and repealing Regulation (EC) No 1222/2009 (OJ L 177, 5.6.2020, p. 1). ( 20 ) Regulation (EC) No 661/2009 of the European Parliament and of the Council of 13 July 2009 concerning type-approval requirements for the general safety of motor vehicles, their trailers and systems, components and separate technical units intended therefor (OJ L 200, 31.7.2009, p. 1). ( 21 ) Regulation (EU) 2019/2144 of the European Parliament and of the Council of 27 November 2019 on type-approval requirements for motor vehicles and their trailers, and systems, components and separate technical units intended for such vehicles, as regards their general safety and the protection of vehicle occupants and vulnerable road users, amending Regulation (EU) 2018/858 of the European Parliament and of the Council (OJ L 325, 16.12.2019, p. 1) ( 22 ) Regulation No 30 of the Economic Commission for Europe of the United Nations (UN/ECE) — Uniform provisions concerning the approval of pneumatic tyres for motor vehicles and their trailers (OJ L 201, 30.7.2008, p. 70). ( 23 ) determined in accordance with points 4.3.5 and 4.3.6 of this Annex
Changed in this version