Skip to content

Compare versions of UN R37

Filament light sources for use in approved lamps of power-driven vehicles and of their trailers

80 changed · 2 added · 83 deleted
1.changed
This Regulation applies to filament lamps light sources shown in Annex 1 and intended for use in approved lamp units lamps of power-driven vehicles and of their trailers.
2.1.1.changed
The term "category" is used in this Regulation to describe different basic design of standardised filament lamps. light sources. Each category has a specific designation, as for example: "H4", "P21W", "T4W", "PY21W"or "RR10W".
2.1.2.changed
Filament lamps light sources of different1 "types" are filament lamps light sources within the same category which differ in such essential respects as:
2.1.2.1.changed
Trade name or mark (Filament lamps light sources bearing the same trade name or mark but produced by different manufacturers are considered as being of different types. Filament lamps light sources produced by the same manufacturer differing only by the trade name or mark may be considered to be of the same type);
2.2.2.2.changed
A brief technical description; this shall include the shape of the filament if the relevant light source sheet specifies that a straight or V-shaped filament is allowed;
2.2.2.3.changed
Five samples of each colour which has been applied for; 1 A selective-yellow bulb or an additional selective-yellow outer bulb, solely intended to change the colour but not the other characteristics of a filament light source emitting white light, does not constitute a change of type of the filament light source.
2.2.3.changed
In the case of a type of filament lamp light source differing only by the trade name or mark from a type that has already been approved it shall be sufficient to submit: A selective-yellow bulb or an additional selective-yellow outer bulb, solely intended to change the colour but not the other characteristics of a filament lamp emitting white light, does not constitute a change of type of the filament lamp.
2.2.4.changed
The competent authority Type Approval Authority shall verify the existence of satisfactory arrangements for ensuring effective control of the conformity of production before type approval is granted.
2.3.1.changed
Filament lamps light sources submitted for approval shall bear on the cap or bulb2:
2.3.1.2.changed
The rated voltage. However, for filament lamps light sources for which only a 12 V type is standardised and the maximum allowed bulb diameter of which does not exceed 7.5 mm, the rated voltage need not be marked;
2.3.1.3.changed
The international designation of the relevant category. The wattage character "W" of this designation need not be marked when the maximum allowed bulb diameter of the filament lamp light source type does not exceed 7.5 mm;
2.3.1.4.changed
The rated wattage (in the sequence, high wattage/low wattage filament for dual-filament lamps); light sources); this need not be indicated separately if it is part of the international designation of the relevant filament lamp light source category;
2.3.3.changed
Halogen filament lamps light sources meeting the requirements of paragraph 3.7. below shall be marked with a "U".
2.4.1.changed
If all samples of a type of filament lamp light source which are submitted in pursuance of paragraphs 2.2.2.3. or 2.2.3.2. above meet the requirements of this Regulation, approval shall be granted.
2.4.2.changed
An approval code shall be assigned to each type approved. Its first character (at present 2, corresponding to the 02 series of amendments which entered into force on 27 October 1983 and to the 03 series of amendments (not requiring changes in the approval number), which entered into force on 1 June 1984) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue of the approval. This will be followed by an identification code comprising not more than two characters. Only the Arabic numerals and capital letters listed in footnote3 shall be used. The same Contracting Party 2 In the latter case, the luminous characteristics shall not be adversely affected. 0123456789 ABCDEFGHJKLMNPRSTUVWXYZ comprising not more than three characters. Only the Arabic numerals and capital letters listed in footnote 3 shall be used. The same Contracting Party may not assign the same code to another type of filament lamp. light source. Notice of approval or of extension or refusal or withdrawal of approval or production definitively discontinued of a type of filament lamp light source pursuant to this Regulation shall be communicated to the Parties of the Agreement which apply this Regulation by means of a form conforming to the model in Annex 2 to this Regulation and of a drawing, supplied by the applicant for approval in a format not exceeding A4 (210 x 297 mm) and on a scale of at least 2: 1. 2:1. If the applicant so desires, the same approval code may be assigned to the filament lamp light source emitting white light and to the filament lamp light source emitting selective-yellow light (see para. 2.1.2.3.).
2.4.3.changed
To every filament lamp light source conforming to a type approved under this Regulation there shall be affixed in the space referred to in paragraph 2.3.1.5., in addition to the inscriptions required under paragraph 2.3.1., an international approval mark consisting of:
2.4.3.1.changed
A truncated circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval4; approval4.
3.1.added
The definitions given in Resolution R.E.5 or its subsequent revisions, applicable at the time of application for type approval shall apply.
3.1.1.deleted
Rated voltage: voltage (in volts) marked on the filament lamp;
3.1.2.deleted
Rated wattage: wattage (in watts) marked on the filament lamp which may be incorporated into the international designation of the relevant category;
3.2.2.changed
Filament lamps light sources shall be so designed as to be and to remain in good working order when in normal use. They shall moreover exhibit no fault in design or manufacture.
3.1.3.deleted
Test voltage: voltage, at the filament lamp terminals for which the electrical and photometric characteristics of the filament lamp are intended and are to be tested.
3.2.3.changed
The filament(s) as specified in the data sheet of the relevant category in Annex 1 shall be the only element(s) of the filament lamp light source that generate and emit light when energised. 3 0123456789 ABCDEFGHJKLMNPRSTUVWXYZ 4 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document TRANS/WP.29/78/Rev.4.
3.1.4.deleted
Objective values: values to be achieved, within the specified tolerances, when the filament lamp is supplied with current at its test voltage;
3.1.5.deleted
Standard (étalon) filament lamp: a filament lamp emitting white or amber or red light with reduced dimensional tolerances, used for the photometric testing of lighting and light-signalling devices. Standard filament lamps are specified in only one voltage rating for each category; The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to Consolidated Resolution on the Construction of Vehicles (R.E.3), document TRANS/WP.29/78/Rev.2/Amend.1.
3.3.1.changed
Filament lamp light source bulbs shall exhibit no scores or spots which might impair their efficiency and their optical performance.
3.1.6.deleted
Reference luminous flux: specified luminous flux of a standard filament lamp to which the optical characteristics of a lighting device shall be referred;
3.3.2.changed
Filament lamps light sources shall be equipped with standard caps complying with the cap data sheets of IEC Publication 60061, third edition, as specified on the individual data sheets of Annex 1.
3.1.7.deleted
Measuring luminous flux: specified value of the luminous flux for testing a filament lamp in a standard headlamp as specified in paragraph 3.8.;
3.1.8.deleted
Reference axis: an axis defined with reference to the cap and to which certain dimensions of the filament lamp are referred;
3.3.4.changed
To ascertain whether filament lamps light sources conform to the requirements of paragraphs 3.3.1. to 3.3.3. above, a visual inspection, a dimension check and, where necessary, a trial fitting shall be carried out.
3.1.9.deleted
Reference plane: a plane defined with reference to the cap and to which certain dimensions of the filament lamp are referred.
3.1.10.deleted
Filament light source (filament lamp): a light source where the element for visible radiation is one or more heated filaments producing thermal radiation.
3.4.1.changed
Filament lamps light sources shall first be aged at their test voltage for approximately one hour. For dual-filament lamps, light sources, each filament shall be aged separately. In the case of filament lamps, light sources, for which more than one test voltage is specified, the highest test voltage value shall be used for ageing.
3.4.2.changed
In the case of a filament lamp light source having a coated bulb, after the ageing period corresponding to paragraph 3.4.1., the surface of the bulb shall be lightly wiped with a cotton cloth soaked in a mixture of 70 vol. per cent of n-heptane n- heptane and 30 vol. per cent of toluol. After about five minutes, the surface shall be inspected visually. It shall not show any apparent changes.
3.4.3.changed
The position and dimensions of the filament shall be measured with the filament lamps light sources being supplied with current at from 90 per cent to 100 per cent of the test voltage. In the case of filament lamps, light sources, for which more than one test voltage is specified, the highest test voltage value shall be used for measurement of the position and dimensions of the filament.
3.4.6.changed
The luminous flux (in lumen) specified on the filament lamp data sheets of Annex 1 is valid for filament lamps emitting white light unless a special colour is stated there. In the case where the selective-yellow colour is allowed, the luminous flux of the filament lamp light source with the selective-yellow outer bulb shall be at least 85 per cent of the specified luminous flux of the relevant filament lamp light source emitting white light.
3.5.1.changed
The geometric shapes of the filament shall in principle be as specified on the filament lamp light source data sheets of Annex 1.
3.5.3.changed
If the filament is shown on the filament lamp light source data sheet in at least one view as a point, the position of the luminous centre shall be determined in conformity with Annex 4.
3.5.4.changed
The length of a line filament shall be determined by its ends, defined - — unless otherwise specified on the relevant data sheet - — as the apices of the first and the last filament turn as seen in projection perpendicular to the reference axis of the filament lamp. light source. Such an apex shall comply with the requirement that the angle formed by the legs shall not exceed 90°. In the case of coiled-coil filaments the apices of the secondary turns shall be taken into account. Apices outside the point of connection to the current lead-in legs shall be disregarded for the determination of the filament length.
3.5.4.1.changed
For axial filaments the extreme position of the apices considered shall be determined by rotating the filament lamp light source about its reference axis. The length shall then be measured in a direction parallel to the reference axis.
3.6.1.changed
The colour of the light emitted by the filament lamp light source shall be white unless otherwise specified on the relevant data sheet.
3.6.3.changed
The colour of the light emitted shall be measured by the method specified in Annex 5. Each measured value shall lie within the required tolerance area5. Moreover, in the case of filament lamps light sources emitting white light, the measured values shall not deviate more than 0.020 unit in the x and/or y direction from For Conformity of Production purposes of amber and red colour only, at least 80 per cent of the measuring results shall lie within the required tolerance area. a point of choice on the Planckian locus (IEC Publication 15.2 Colorimetry, 1986). (CIE 015:2004, 3rd edition). Filament lamps light sources for use in light signalling devices shall meet the requirements as specified in paragraph 2.4.2. of IEC Publication 60809, Amendment 5 to Edition 2. 3.
3.7.changed
The UV radiation of a halogen lamp filament light source shall be such that: 400 nm ∫ Ee()∙d =315  Ee ( )  d   315 nm k1 = ____________________ ≤   2 ∙ 10-4 W/lm  10 4 W / lm 780 nm km ∙ ∫ Ee()∙V()∙d =380  Ee ( )  V    d    380 nm 5 For conformity of production purposes of amber and red colour only, at least 80 per cent of the measuring results shall lie within the required tolerance area. 315 nm ∫ Ee()∙d =250  Ee ( )  d   250 nm k2 = ____________________ ≤   2 ∙ 10-6 W/lm  10 6 W / lm 780 nm km ∙ ∫ Ee()∙V()∙d =380  Ee ( )  V    d    380 nm where: Where: Ee () (W/nm) is the spectral distribution of the radiant flux; V () (1) is the spectral luminous efficiency; km = 683 (lm/W) is the photometric radiation equivalent;  (nm) is the wave length. This value shall be calculated using intervals of five nanometres.
3.8.changed
An approval of a filament lamp light source type under this Regulation may be granted, pursuant to paragraph 3.6. above, for a filament lamp light source emitting white light as well as selective-yellow light; Article 3 of the Agreement to which this Regulation is annexed shall not prevent the Contracting Parties from prohibiting, on vehicles registered by them, filament lamps light sources emitting either white or selective-yellow light.
3.9.changed
Check on optical quality (Applies only to filament lamps of categories R2, H4 and HS1). light sources with an internal shield to produce the cut-off).
3.9.2.changed
For 12-Volt 12-volt filament lamps light sources emitting white light: The sample which most nearly conforms to the requirements laid down for the standard filament lamp light source shall be tested in a standard headlamp as specified in paragraph 3.9.5. and it shall be verified whether the assembly comprising the aforesaid headlamp and the filament lamp light source being tested meets the light- distribution requirements laid down for the passing beam in the relevant Regulation.
3.9.3.changed
For 6-Volt 6-volt and 24-Volt 24-volt filament lamps light sources emitting white light: The sample which most nearly conforms to the nominal dimension values shall be tested in a standard headlamp as specified in paragraph 3.9.5. and it shall be verified whether the assembly comprising the aforesaid headlamp and the filament lamp light source being tested meets the light-distribution requirements laid down for the passing beam in the relevant Regulation. Deviations not exceeding 10 per cent of the minimum values will be acceptable.
3.9.4.changed
Filament lamps light sources emitting selective-yellow light shall be tested in the same manner as described in paragraphs 3.9.2. and 3.9.3. in a standard headlamp as specified in paragraph 3.9.5. to ensure that the illumination complies with at least 85 per cent for 12-Volt 12-volt filament lamps, light sources, and at least 77 per cent for 6-Volt 6-volt and 24-Volt 24-volt filament lamps, light sources, with the minimum values of the light- distribution light-distribution requirements laid down for the passing beam in the relevant Regulation. The maximum illumination limits remain unchanged. In the case of a filament lamp light source having a selective-yellow bulb, this test shall be left out if the approval is also given to the same type of filament lamp light source emitting white light.
3.9.5.3.changed
With a standard filament lamp light source it produces at the various points and in the various zones specified for the headlamp type concerned, illumination equal to:
3.10.changed
Additional requirements for standard (étalon) filament lamps light sources are given on the relevant data sheets of Annex 1. Bulbs of standard (étalon) filament lamps light sources emitting white light shall not alter the CIE trichromatic coordinates of a luminous source having a colour temperature of 2,856 K by more than 0.010 units in the x and/or y direction. For standard (étalon) filament lamps light sources emitting amber or red light, changes of the bulb temperature shall not affect the luminous flux which might impair photometric measurements of signalling devices.
4.1.changed
Filament lamps light sources approved to this Regulation shall be so manufactured as to conform to the type approved by meeting the inscriptions and technical requirements set forth in paragraph 3. above and Annexes 1, 3 and 4 to this Regulation.
4.3.1.changed
Ensure existence of procedures for the effective control of the quality of products, products;
4.3.2.changed
Have access to the control equipment necessary for checking the conformity to each approved type, type;
4.3.3.changed
Ensure that data of test results are recorded and that related documents shall remain available for a period to be determined in accordance with the administrative service, Type Approval Authority;
4.3.4.changed
Analyse the results of each type of test, applying criteria of Annex 7, in order to verify and ensure the stability of the product characteristics making allowance for variation of an industrial production, production;
4.3.5.changed
Ensure that for each type of filament lamp, light source, at least the tests prescribed in Annex 6 to this Regulation are carried out, out;
4.4.changed
The competent authority Type Approval Authority which has granted type-approval may at any time verify the conformity control methods applicable to each production unit.
4.4.4.changed
The competent authority Type Approval Authority may carry out any tests prescribed in this Regulation. Where the competent authority Type Approval Authority decides to carry out spot checks, criteria of Annexes 8 and 9 to this Regulation shall be applied.
4.4.5.changed
The normal frequency of inspection authorised by the competent authority Authority shall be one every two years. In the case where negative results are recorded during one of these visits, the competent authority Type Approval Authority shall ensure that all necessary steps are taken to re-establish the conformity of production as rapidly as possible.
5.1.changed
The approval granted in respect of a filament lamp light source pursuant to this Regulation may be withdrawn if the requirements are not met or if a filament lamp light source bearing the approval mark does not conform to the type approved.
6.changed
If the holder of the approval completely ceases to manufacture a type of filament lamp light source approved in accordance with this Regulation, he shall so inform the Type Approval Authority which has granted the approval. Upon receiving the relevant communication, that Type Approval Authority shall inform thereof the other Parties to the 1958 Agreement applying this Regulation by means of a communication form conforming to the model in Annex 2 to this Regulation.
7.changed
Names and addresses of the Technical Services responsible for conducting approval tests, tests and of Type Approval Authorities The Parties to the 1958 Agreement which apply this Regulation shall communicate to the United Nations secretariat the names and addresses of the Technical Services responsible for conducting approval tests and of the Type Approval Authorities which grant approval and to which forms certifying approval or extension or refusal or withdrawal of approval, or production definitively discontinued issued in other countries, are to be sent.
8.1.changed
Approvals granted under the preceding series of amendments shall remain valid, except that for conformity of production, current production filament lamps light sources shall comply with the requirements of the latest series of amendments starting 12 months from the date of application of this amendment 6. 8.2 The correspondence between the former designations and the new ones is indicated in the following table: New designations in the 03 series Old designations of amendments P25-1 P21W P25-2 P21/5W R19/5 R5W R19/10 R10W C11 C5W C15 C21W T8/4 T4W W10/5 W5W W10/3 W3W The amended text of this paragraph was introduced by Supplement 14 to the 03 series of amendments. This supplement entered into force on 3 September 1997 and it also introduced in the text of the Regulation new paragraphs 2.3.3. and 3.7. and in Annex 1 new sheets HIR1 and PY27/7W. amendment.6
8.2.added
The correspondence between the former designations and the new ones is indicated in the following table: New designations in the 03 series Old designations of amendments P25-1 P21W P25-2 P21/5W R19/5 R5W R19/10 R10W C11 C5W C15 C21W T8/4 T4W W10/5 W5W W10/3 W3W 6 The amended text of this paragraph was introduced by Supplement 14 to the 03 series of amendments. This supplement entered into force on 3 September 1997 and it also introduced in the text of the Regulation new paragraphs 2.3.3. and 3.7. and in Annex 1 new sheets HIR1 and PY27/7W.
Annex 1changed
List The sheets of categories the relevant filament light source category and the group in which this category is listed with restrictions on the use of this category shall apply as incorporated in Resolution [R.E.4] or its subsequent revisions, applicable at the time of application for type approval of the filament light source. . * From [date] onwards, the sheets for filament light sources, the list and groups of filament lamps, grouped light source categories with their restrictions on the use and their sheet numbers: Group 1 Without general restrictions: Category Sheet number(s) H1 H1/1 to 3 H3 H3/1 to 4 H4 H4/1 to 5 H7 H7/1 to 4 H8 H8/1 to 4 H8B H8/1 to 4 H9 *** H9/1 to 4 H9B *** H9/1 to 4 H10 H10/1 to 3 H11 H11/1 to 4 H11B H11/1 to 4 H12 H12/1 to 3 H13 H13/1 to 4 H13A H13/1 to 4 H14 H14/1 to 4 H15 H15/1 to 5 H16 H16/1 to 4 H16B H16/1 to 4 H21W ** H21W/1 to 2 H27W/1 H27W/1 to 3 H27W/2 H27W/1 to 3 HB3 HB3/1 to 4 HB3A HB3/1 to 4 HB4 HB4/1 to 4 HB4A HB4/1 to 4 HIR1 *** HIR1/1 to 3 HIR2 HIR2/1 to 3 HS1 HS1/1 to 5 HS2 HS2/1 to 3 HS5 HS5/1 to 4 HS5A ***** HS5A/1 to 3 HS6 **** HS6/1 to 4 PSX24W ** P24W/1 to 3 PSX26W ** PSX26W1 to 3 PX24W ** P24W/1 to 3 S2 S1/S2/1 to 2 S3 S3/1 Annex 1 Group 2 Only for use numbers are incorporated in signalling lamps, cornering lamps, reversing lamps and rear registration plate lamps: Category Sheet number(s) C5W C5W/1 H6W H6W/1 H10W/1 H10W/1 to 2 HY6W H6W/1 HY10W H10W/1 to 2 HY21W H21W/1 to 2 P13W P13W/1 to 3 P21W P21W/1 to 2 P21/4W P21/4W/1 (P21/5W/2 to 3) P21/5W P21/5W/1 to 3 P24W P24W/1 to 3 P27W P27W/1 to 2 P27/7W P27/7W/1 to 3 PR21W PR21W/1 (P21W/2) PR21/4W PR21/4W/1 (P21/5W/2 to 3) PR21/5W PR21/5W/1 (P21/5W/2 to 3) PR27/7W PR27/7W/1 (P27/7W/2 to 3) PS19W P19W/1 to 3 PS24W P24W/1 to 3 PSY19W P19W/1 to 3 PSY24W P24W/1 to 3 PW13W P13W/1 to 3 PW16W PC16W/1 to 3 PWR16W PC16W/1 to 3 PWY16W PC16W/1 to 3 PW19W P19W/1 to 3 PWR19W P19W/1 to 3 PWY19W P19W/1 to 3 PW24W P24W/1 to 3 PWR24W P24W/1 to 3 PWY24W P24W/1 to 3 PY21W PY21W/1 (P21W/2) PY24W P24W/1 to 3 PY27/7W PY27/7W/1 (P27/7W/2 to 3) R5W R5W/1 R10W R10W/1 RR5W R5W/1 RR10W R10W/1 Category Sheet number(s) RY10W R10W/1 T1.4W T1.4W/1 T4W T4W/1 W2.3W W2.3W/1 W3W W3W/1 W5W W5W/1 W10W W10W/1 W15/5W W15/5W/1 to 3 W16W W16W/1 W21W W21W/1 to 2 W21/5W W21/5W/1 to 3 WP21W WP21W/1 to 2 WPY21W WP21W/1 to 2 WR5W W5W/1 WR21/5W WR21/5W/1 (W21/5W/2 to 3) WY2.3W WY2.3W/1 WY5W W5W/1 WY10W W10W/1 WY16W W16W/1 WY21W WY21W/1 to 2 Annex 1 Group 3 For replacement purposes only (see transitional provisions of paragraphs 8.3. and 8.4.): Category Sheet number(s) C21W C21W/1 to 2 P19W P19W/1 to 3 PC16W PC16W/1 to 3 PCR16W PC16W/1 to 3 PCY16W PC16W/1 to 3 PR19W P19W/1 to 3 PR24W P24W/1 to 3 PSR19W P19W/1 to 3 PSR24W P24W/1 to 3 PY19W P19W/1 to 3 R2 R2/1 to 3 S1 S1/S2/1 to 2 * Tables, Electrical and Photometric characteristics: Voltage is expressed in V; Wattage is expressed in W; Luminous flux is expressed in lm. In a case that for a category of filament lamp more than one value of reference luminous flux is specified, the value at approximately 12 V for approval of a lighting device and 13.5 V for approval of a light-signalling device shall be applied unless otherwise specified by the regulation used for the approval of the device. ** Not for use in passing beam headlamps. *** Not for use in front fog lamps marked "B" as defined in Regulation No. 19. **** Not for use in Regulation No. 112 headlamps. ***** Not for use in headlamps other than Regulation No.113 class C headlamps. List of sheets for filament lamps and their sequence in this annex: Sheet number(s) C5W/1 C21W/1 to 2 H1/1 to 3 H3/1 to 4 H4/1 to 5 H7/1 to 4 H8/1 to 4 H9/1 to 4 H10/1 to 3 H11/1 to 4 H12/1 to 3 H13/1 to 4 H14/1 to 4 H15/1 to 5 H16/1 to 4 H6W/1 H10W/1 to 2 H21W/1 to 2 H27W/1 to 3 HB3/1 to 4 HB4/1 to 4 HIR1/1 to 3 HIR2/1 to 3 HS1/1 to 5 HS2/1 to 3 HS5/1 to 4 HS5A/1 to 3 HS6/1 to 4 P13W/1 to 3 P19W/1 to 3 P21W/1 to 2 P21/4W/1 P21/5W/1 to 3 P24W/1 to 3 P27W/1 to 2 P27/7W/1 to 3 PC16W/1 to 3 PR21W/1 Annex 1 Sheet number(s) PR21/4W/1 PR21/5W/1 PR27/7W/1 PSX26W/1 to 3 PY21W/1 PY27/7W/1 R2/1 to 3 R5W/1 R10W/1 S1/S2/1 to 2 S3/1 T1.4W/1 T4W/1 W2.3W/1 W3W/1 W5W/1 W10W/1 W15/5W/1 to 3 W16W/1 W21W/1 to 2 W21/5W/1 to 3 WP21W/1 to 2 WR21/5W/1 WY2.3W/1 WY21W/1 to 2 Category C5W Sheet C5W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. b 1/ 34.0 35.0 36.0 35.0  0.5 2/,3/ 4/ 5/ f 7.5 15 9  1.5 Cap SV8.5 in accordance with IEC Publication 60061 (sheet 7004-81-4) Electrical and photometric characteristics Volts 6 12 24 12 Rated values Watts 5 5 Test voltage Volts 6.75 13.5 28.0 13.5 Objective Watts 5.5 max. 7.7 max. 5.5 max. values Luminous flux 45  20 % Reference luminous flux: 45 lm at approximately 13.5 V 1/ This dimension corresponds to a distance between two apertures of 3.5 mm diameter each bearing against one of the caps. 2/ The filament shall be housed in a cylinder 19 mm long co-axial with the filament lamp and placed symmetrically about the filament lamp centre. The diameter of the cylinder is for 6 V and 12 V filament lamps: d + 4 mm (for standard filament lamps: d + 2 mm) and for 24 V filament lamps: d + 5 mm, "d" being the nominal diameter of the filament as stated by the manufacturer. 3/ The deviation of the filament centre from the centre of the filament lamp shall not be more than ±2.0 mm (for standard filament lamps: ±0.5 mm) measured in the direction of the reference axis. 4/ 4.5 mm for 6 V filament lamps. 5/ 16.5 mm for 24 V filament lamps. Annex 1 Category C21W Sheet C21W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamp for reversing lamp only Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. b 1/ 40.0 41.0 42.0 41.0  0.5 f 2/ 7.5 10.5 8  1.0 Cap SV8.5 in accordance with IEC Publication 60061 (sheet 7004-81-4) Electrical and photometric characteristics Volts 12 12 Rated values Watts 21 21 Test voltage Volts 13.5 13.5 Objective Watts 26.5 max. 26.5 max. values Luminous flux 460  15 % Reference luminous flux: 460 lm at approximately 13.5 V 1/ This dimension corresponds to a distance between two apertures of 3.5 mm diameter. 2/ The position of the filament is checked by means of a "Box-System"; sheet C21W/2. Category C21W Sheet C21W/2 Screen projection requirements This test is used to determine, by checking whether the filament is correctly positioned relative to the reference axis and to the centre of the filament lamp's length, whether a filament lamp complies with the requirements. 12 V a h k Filament lamps of normal production 4.0 + d 14.5 2.0 Standard filament lamp 2.0 + d 14.5 0.5 d = nominal filament diameter as stated by the manufacturer. Test procedure and requirements Resolution [R.E.4] (ECE/TRANS/WP.29/2016/111) E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
Annex 2changed
(Maximum format: A4 (210 x 297 mm)) issued by: Name of administration concerning2: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a type of filament lamp light source pursuant to Regulation No. 37 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation). 2 Strike out what does not apply. Annex 2 Colour of the light emitted: White/selective-yellow/amber/red2 Colour coating on glass bulb: yes/no2 Halogen filament lamp: light source: yes/no2
16.changed
The following documents, bearing the approval mark shown above, are E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
Annex 3changed
(see (See paragraph 2.4.3.) 2.4.3) The above approval mark affixed to a filament lamp light source indicates that the lamp light source has been approved in the United Kingdom (E11) (E 11) under the approval code A1. A01. The first character of the approval code indicates that the approval was granted in accordance with the requirements of Regulation No. No 37 as amended by the 02 and 03* 03 * series of amendments. * Not requiring changes in the approval number. Annex 4 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
Annex 4changed
Save as possibly Unless otherwise stated on the filament lamp light source data sheets, this standard annex is applicable to the determination of the luminous centre of different filament shapes. The position of the luminous centre depends upon the filament shape. No. Filament shapes Observations With b > 1.5 h, the deviation of the filament axis with respect to a plane normal to the reference axis shall not exceed 15° Only applicable to filaments which can be inscribed in a rectangle of b > 3h. Applicable to filaments which can be inscribed in a rectangle of b  3h, h/3 whereby, however, k < 2h. h k b/2 b The side lines of the circumscribed rectangles in Nos. 2 and 3 are parallel and perpendicular, respectively, to the reference axis. The luminous centre is the intersection of the dash-dot lines. The drawings are intended only to demonstrate the essential dimensions. E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
1.1.changed
Measurements shall be made on finished lamps. light sources. Filament lamps light sources with secondary (outer) bulb acting as colour filter shall be handled as filament lamp light source with primary bulb.
8.3.deleted
No filament lamps of the categories listed below shall be used in lamps submitted for type approval after the period following the entry into force of Supplements to 03 series of amendments, as indicated for each category in the table below: Category Supplement Period C21W 28 12 months P19W 37 60 months PC16W 37 60 months PCR16W 37 12 months PCY16W 37 60 months PR19W 37 12 months PR24W 37 12 months PSR19W 37 12 months PSR24W 37 12 months PY19W 37 60 months R2 28 12 months S1 28 12 months
1.3.changed
Tests shall be made at test voltage(s) as specified in the relevant lamp filament light source data sheet.
8.4.deleted
However, Contracting Parties applying this Regulation may continue to grant approvals for lamps in which filament lamps of categories listed below are used, provided that these lamps are intended as replacement parts for installation on vehicles in use for the period after entry into force of the Supplements to the 03 series of amendments as indicated below: Category Supplement Period C21W 28 unlimited P19W 37 unlimited PC16W 37 unlimited PCR16W 37 unlimited PCY16W 37 unlimited PR19W 37 unlimited PR24W 37 unlimited PSR19W 37 unlimited PSR24W 37 unlimited PY19W 37 unlimited R2 28 unlimited S1 28 unlimited Annex 1
1.4.changed
Filament lamps light sources shall be measured preferably in the normal operating position. In case of dual filament lamps light sources the high wattage (major or driving beam) filament shall be operated only.
1.5.changed
Before starting a test, the stabilisation of the temperature of the filament lamp light source shall be obtained by operating at test voltage for 10 minutes. In the case of filament lamps, light sources, for which more than one test voltage is specified, the relevant test voltage value shall be used for achieving stabilization.
1.deleted
The filament lamp is placed in a holder (socket) capable of being so rotated through 360° about the reference axis that the front elevation is seen on the screen on to which the image of the filament is projected. The reference plane on the screen shall coincide with the centre of the filament lamp. The central axis sought on the screen shall coincide with the centre of the filament lamp length.
2.1.deleted
The projection of the filament shall lie entirely within the rectangle when the filament lamp is rotated through 360°.
2.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the central axis sought. Annex 1 Category H1 Sheet H1/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp 1/ The reference axis is perpendicular to the reference plane and passes through the point defined by the dimensions marked with 1. 2/ Both current lead-in electrodes shall be positioned in the bulb, the longer electrode above the filament (the filament lamp being viewed as shown in the figure). The internal design should be then such that stray light images and reflections are reduced to the minimum, e.g. by fitting cooling jackets over the non-coiled parts of the filament. 3/ The cylindrical portion of the bulb over length "f" shall be such as not to deform the projected image of the filament to such an extent as appreciably to affect the optical results. 4/ The colour of the light emitted shall be white or selective-yellow. Category H1 Sheet H1/2 Filament lamps of normal production Standard filament lamp Dimensions in mm 6V 12 V 24 V 12 V 6/,10/ …
Figure 1deleted
The filament shall lie entirely within the limits shown. The ends of the filament as defined on sheet H7/3, footnote 9/, shall lie between lines Z1 and Z2 and between Z3 and Z4. Annex 1 Categories H8 and H8B Sheet H8/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp
2.3.1.changed
Initially, the receiver shall be positioned perpendicular to the lamp filament light source axis and to the filament axis (or plane in case of a curved filament). After measurement the receiver shall be moved around the filament lamp light source in bi-directional steps of about 30° until the area specified in paragraphs 2.3.2. or 2.3.3. is covered. In each position a measurement shall be made. However, no measurement shall be made when: (a) The centreline of the receiver coincides with the filament axis; or (b) The line of sight between the receiver and the filament is blocked by opaque (non-transmitting) parts of the light source, such as lead wires or a second filament, if any.
Figure 2deleted
1/ The reference plane is the plane formed by the underside of the bevelled lead-in flange of the cap. 2/ The reference axis is perpendicular to the reference plane and passing through the centre of the 19 mm cap diameter. 3/ Glass bulb and supports shall not exceed the envelope as indicated in Figure 2. The envelope is concentric to the reference axis. 4/ The colour of the light emitted shall be white or selective-yellow. 5/ Notes concerning the filament diameter. (a) No actual diameter restrictions apply but the objective for future developments is to have d max. = 1.2 mm. (b) For the same manufacturer, the design diameter of standard (étalon) filament lamp and filament lamp of normal production shall be the same. Categories H8 and H8B Sheet H8/2 6/ Glass bulb shall be optically distortion free within the angles 1 and 2. This requirement applies to the whole bulb circumference within the angles 1 and 2. 7/ The obscuration shall extend at least to the cylindrical part of the bulb on the whole bulb top circumference. It shall moreover extend at least to a plane parallel to the reference plane where 3 crosses the outer bulb surface (view B as indicated on sheet H8/1). 8/ The internal design of the lamp shall be such that stray light images and reflections are only located above the filament itself seen from the horizontal direction. (View A as indicated in Figure 1 on sh…
2.3.2.changed
For filament lamps light sources used in headlamps, measurements shall be made in directions around the filament lamp light source with the centreline of the receiver aperture located within an angle ±30°, from the plane perpendicular to the lamp filament light source axis with the origin in the centre of the filament. In case of filament lamps light sources with two filaments, the centre of the driving beam filament shall be taken. Annex 5 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.
2.3.3.changed
For filament lamps light sources used in light signalling devices, measurements shall be made in directions around the filament lamp light source with exception of: (a) The area claimed or covered by the cap of the filament lamp; light source; and (b) The immediate transition area along the cap. In case of filament lamps light sources with two filaments, the centre of the major filament shall be taken. In case of filament light source categories with a defined distortion-free angle, the measurement shall be done only within the defined angle. Figure illustrating the positions of colourimetric receiver Centreline of receiver shall move within angle and around the filament light source Receiver shall move around filament but aperture shall not overlap any cap or base part and its immediate transition area. In case of filament light source categories with a defined distortion-free angle, the measurement shall be done only within the defined angle. E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
1.changed
The conformity requirements shall be considered satisfied from a photometric, geometrical, visual and electrical standpoint if the specified tolerances for production filament lamps light sources in the relevant data sheet of Annex 1 and the relevant data sheet for the caps are met.
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament;
2.changed
For each type of filament lamp light source the manufacturer or the holder of the approval mark shall carry out tests, in accordance with the provisions of this Regulation, at appropriate intervals.
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis. Annex 1 Categories H27W/1 and H27W/2 Sheet H27W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp 1/ The reference plane is defined by the plane formed by the underside of the bevelled lead-in flange of the cap. 2/ The reference axis is perpendicular to the reference plane and passes through the centre of the 13.10 mm cap diameter. 3/ Glass bulb and supports shall not exceed the size of a theoretical cylinder centred on the reference axis. 4/ The obscuration shall extend over the whole bulb top including the bulb cylindrical portion up to the intersection with 1. Categories H27W/1 and H27W/2 Sheet H27W/2 Filament dimensions and position (Dimensions f for all filament lamps) (Dimensions h1, h2, h3, h4 and k for standard filament lamps only) Dimensions in mm Filament lamp of normal production Standard filament lamp 6/ e 31.75 31.75  0.25 8/ f 4.8 max. 4.2  0.20 6/ k …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
2.2.2.changed
The application of paragraph 2.2.1. requires regular calibration of test apparatus and its correlation with measurements made by a competent authority. Type Approval Authority.
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.
2.3.changed
Samples of filament lamps light sources shall be selected at random from the production of a uniform batch. A uniform batch means a set of filament lamps light sources of the same type, defined according to the production methods of the manufacturer.
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis. Annex 1 Category P21/4W Sheet P21/4W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. 1/ e 31.8 31.8  0.3 f 7.0 7.0 + 0 /- 2 1/ Lateral deviation 0.3 max. 2/ 1/ x,y 2.8  0.5 1/ 1/ 1/  75° 90° 105° 90°  5° Cap BAZ15d in accordance with IEC Publication 60061 (sheet 7004-11C-3) Electrical and photometric characteristics Rated Volts 12 24 12 values Watts …
2.4.changed
The filament lamps light sources shall be inspected and test results recorded following the grouping of characteristics as listed in Annex 7, Table 1.
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. (i.e. 15°). The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits.
2.5.changed
The manufacturer or the holder of approval is responsible for carrying out a statistical study of the test results in order to meet the specifications laid down for verification of conformity of production in paragraph 4.1. of this Regulation. Compliance shall be assured if the level of acceptable non-compliance per grouping of characteristics given in Table 1 of Annex 7 is not exceeded. This means that the number of filament lamps light sources not complying with the requirement for any grouping of characteristics of any filament lamp light source type does not exceed the qualifying limits in the relevant Tables 2, 3 or 4 of Annex 7. Note: Each individual filament lamp light source requirement shall be considered as a characteristic. Annex 7 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
2.deleted
The filament lamp placed with the cap down, the reference axis vertical, the reference pin to the right and the major filament seen end-on:
2.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;
Table 1changed
Grouping* of test records Acceptable level of non- Grouping*of test records between filament light Minimum 12 monthly compliance per grouping Grouping of characteristics between lamp source types sample per grouping* of characteristics (%) Marking, legibility All types with the 315 1 and durability same external dimensions Bulb quality All types with the 315 1 same bulb All types (emitting red and amber Colour of the bulb amber light) of the same 20 1 same category and colour technology External lamp filament light All types of the 200 1 source dimensions (excluding same category (excluding cap/base) Dimensions of caps All types of the 200 6.5 and bases same category Dimensions related to All lamps of one filament light 200 6.5 internal elements** sources of one type Initial readings, watts All lamps of one filament light 200 1 and lumens** sources of one type Colour endurance test All lamps (emitting filament light 20*** 1 sources (emitting red, amber and white light) of one colour coating technology * The assessment shall in general cover series production filament lamps light sources from individual factories. A manufacturer may group together records concerning the same type from several factories, provided these operate under the same quality system and quality management. ** In case a filament lamp light source has more than one inner element (filament, shield) the grouping of characteristics (dimensions, watts, lumens) applies to each element separately. *** Representative distribution over categories of lamps filament light sources using the same colour coating technology and finishing, and that comprises lamps filament light sources of the smallest and the largest diameter of the outer bulb, each at the highest rated wattage. E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8 Qualifying limits for acceptance based on different numbers of test results for each grouping of characteristics are listed in Table 2 as maximum number of non-compliance. The limits are based on an acceptable level of 1 per cent of non-compliance, assuming an acceptance probability of at least 0.95.
2.2.deleted
The projection of the minor filament shall lie entirely:
Table 2changed
Number of test results of each characteristics Qualifying limits for acceptance 20 0 21 - 50 1 51 - 80 2 81 - 125 3 126 - 200 5 201 - 260 6 261 - 315 7 316 - 370 8 371 - 435 9 436 - 500 10 501 - 570 11 571 - 645 12 646 - 720 13 721 - 800 14 801 - 860 15 861 - 920 16 921 - 990 17 991 - 1,060 18 1,061 - 1,125 19 1,126 - 1,190 20 1,191 - 1,249 21 * In accordance with ISO 2859-1:1999 "Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by- lot lot-by-lot inspection" including Technical Corrigendum 1:2001. Annex 7 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8 Qualifying limits for acceptance based on different numbers of test results for each grouping of characteristics are listed in Table 3 given as maximum number of non- compliance. The limits are based on an acceptable level of 6.5 per cent of non-compliance, assuming an acceptance probability of at least 0.95.
2.2.1.deleted
Within a rectangle of width "c" and height "d" having its centre at a distance "v" to the right of and at a distance "u" above the theoretical position of the centre of the major filament;
Table 3changed
Number of Number of Number of lamps filament light filament light filament light sources in Qualifying lamps sources in Qualifying lamps sources in Qualifying records limit records limit records limit - 200 21 541 - 553 47 894 - 907 73 201 - 213 22 554 - 567 48 908 - 920 74 214 - 227 23 568 - 580 49 921 - 934 75 228 - 240 24 581 - 594 50 935 - 948 76 241 - 254 25 595 - 608 51 949 - 961 77 255 - 268 26 609 - 621 52 962 - 975 78 269 - 281 27 622 - 635 53 976 - 988 79 282 - 295 28 636 - 648 54 989 - 1,002 80 296 - 308 29 649 - 662 55 1,003 -,1016 81 309 - 322 30 663 - 676 56 1,017 - 1,029 82 323 - 336 31 677 - 689 57 1,030 - 1,043 83 337 - 349 32 690 - 703 58 1,044 - 1,056 84 350 - 363 33 704 - 716 59 1,057 - 1,070 85 364 - 376 34 717 - 730 60 1,071 - 1,084 86 377 - 390 35 731 - 744 61 1,085 - 1,097 87 391 - 404 36 745 - 757 62 1,098 - 1,111 88 405 - 417 37 758 - 771 63 1,112 - 1,124 89 418 - 431 38 772 - 784 64 1,125 - 1,138 90 432 - 444 39 785 - 798 65 1,139 - 1,152 91 445 - 458 40 799 - 812 66 1,153 - 1,165 92 459 - 472 41 813 - 825 67 1,166 - 1,179 93 473 - 485 42 826 - 839 68 1,180 - 1,192 94 486 - 499 43 840 - 852 69 1,193 - 1,206 95 500 - 512 44 853 - 866 70 1,207 - 1,220 96 513 - 526 45 867 - 880 71 1,221 - 1,233 97 527 - 540 46 881 - 893 72 1,234 - 1,249 98 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8 Qualifying limits for acceptance based on different numbers of test results for each grouping of characteristics are listed in Table 4 given as a percentage of the results, assuming an acceptance probability of at least 0.95.
2.2.2.deleted
Above a straight line tangential to the upper edge of the projection of the major filament and rising from left to right at an angle of 25°.
Table 4changed
Qualifying limits shown as a Qualifying limits shown as a percentage of results. percentage of results. Number of test results of each Acceptable level of 1% of non- Acceptable level of 6.5% of non- characteristic compliance compliance 1,250 1.68 7.91 2,000 1.52 7.61 4,000 1.37 7.29 6,000 1.30 7.15 8,000 1.26 7.06 10,000 1.23 7.00 20,000 1.16 6.85 40,000 1.12 6.75 80,000 1.09 6.68 100,000 1.08 6.65 1,000,000 1.02 6.55 Annex 8 E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
2.2.3.deleted
To the right of the projection of the major filament.
3.deleted
The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:
1.changed
The conformity requirements shall be considered satisfied from a photometric, geometrical, visual and electrical standpoint if the specified tolerances for production filament lamps light sources in the relevant data sheet of Annex 1 and the relevant data sheet for the caps are met.
3.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;
2.changed
The conformity of mass-produced filament lamps light sources shall not be contested if the results are in agreement with Annex 9 to this Regulation.
3.2.deleted
The centre of the major filament shall not be offset by more than distance "k" from the reference axis.
3.3.deleted
The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps). Category P21/5W Sheet P21/5W/3 Dimensions in mm Reference a b c d u v Dimensions 3.5 3.0 4.8 2.8 Reference a h k Dimensions 3.5 9.0 1.0 Annex 1 Sheet P24W/1 Categories P24W, PX24W, PY24W, PR24W, PS24W, PSX24W, PSY24W, PSR24W, PW24W, PWY24W and PWR24W The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp 1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ The light emitted from normal production lamps shall be white for categories P24W, PX24W, PS24W, PSX24W and PW24W; amber for categories PY24W, PSY24W and PWY24W; red for categories PR24W, PSR24W and PWR24W (see also footnote 8/). Sheet P24W/2 Categories P24W, PX24W, PY24W, PR24W, PS24W, PSX24W, PSY24W, PSR24W, PW24W, PWY24W and PWR24W Filament lamps of normal production Standard filament lamp Dimens…
4.changed
If paragraph 3 of this annex is applied, a further sample of 250 filament lamps, light sources, selected at random from a recent production run, shall be taken within two months. E/ECE/TRANS/505/ Rev.1/Add.36/Rev.7/Amend.8
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.
Annex 9changed
Compliance approved or disapproved shall be decided according to the values in Table 1. For each grouping of characteristics filament lamps light sources shall be either accepted or rejected according to the values in Table 1*. 1.*
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
Table 1changed
Accept Reject Accept Reject First sample size: 125 2 5 11 16 If the number of non-conforming 6 7 26 27 units is greater than 2 (11) and less than 5 (16) take a second sample size of 125 and assess the 250 * The proposed scheme is designed to assess the compliance of filament lamps light sources to an acceptance level of non-compliance of 1 per cent and 6.5 per cent respectively and is based on the Double Sampling Plan for Normal Inspection in IEC Publication 60410: Sampling Plans and Procedures for Inspection by Attributes. ** The filament lamps light sources shall be inspected and test results recorded following the grouping of characteristics as listed in Annex 7, Table 1. "
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis. Category P27/7W Sheet P27/7W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. 3/ e 27.9 27.9  0.3 f 9.9 9.9 + 0 / -2 2/ 3/ Lateral deviation 0.0  0.4 x 4/ 5.1 3/ 5.1  0.5 y 4/ 0.0 3/ 0.0  0.5  75°3/ 90° 105°3/ 90°  5° Cap W2.5x16q in accordance with IEC Publication 60061 (sheet 7004-104-1) Electrical and photometric characteristics Volts 12 12 Rated values …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits.
2.deleted
The filament lamp placed with the cap down, the reference axis vertical, the reference key to the right and the major filament seen end-on:
2.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;
2.2.deleted
The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.
3.deleted
The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:
3.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;
3.2.deleted
The centre of the major filament shall not be offset by more than distance "k" from the reference axis;
3.3.deleted
The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps). Category P27/7W Sheet P27/7W/3 Reference a b c d u Dimension 3.5 3.0 4.8 5.1 Reference a h k Dimension 3.5 11.9 1.0 Annex 1 Sheet PC16W/1 Categories PC16W, PCY16W, PCR16W, PW16W, PWY16W and PWR16W The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp 1/ The reference plane is defined by the meeting points of the cap-holder fit. 2/ No actual filament diameter restrictions apply but the objective is d max. = 1.1 mm. 3/ The light emitted from normal production lamps shall be white for category PC16W and PW16W; amber for category PCY16W and PWY16W; red for category PCR16W and PWR16W. (see also footnote 7/). Sheet PC16W/2 Categories PC16W, PCY16W, PCR16W, PW16W, PWY16W and PWR16W Filament lamps of normal production Standard filament lamp 7/ Dimensions in mm min. nom. max. PC16W PCY16W …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits. (±15°).
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the major filament seen end-on:
2.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;
2.2.deleted
The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.
3.deleted
The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:
3.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;
3.2.deleted
The centre of the major filament shall not be offset by more than distance "k" from the reference axis.
3.3.deleted
The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps). Annex 1 Category W15/5W Sheet W15/5W/3 Reference a b c d u Dimensions 3.3 2.8 4.8 2.8 Reference a h k Dimensions 3.3 9.5 1.0 Categories W16W AND WY16W Sheet W16W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. e 18.3 20.6 22.9 20.6  0.3 Lateral deviation 1/ 1.0 0.5 max.  -15° 0° +15° 0°  5° Cap W2.1x9.5d in accordance with IEC Publication 60061 (sheet 7004-91-3) Electrical and photometric characteristics Rated Volts 12 12 values Watts 16 …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits, i.e. 15°. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits (15°).
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament;
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis. Annex 1 Category W21/5W Sheet W21/5W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp a = major (high wattage) filament b = minor (low wattage) filament Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. e 25.0 1/ 25.0  0.3 f 7.5 7.5 + 0 / -2 2/ 1/ Lateral deviation 0.3 max. x 3/ 2.8 1/ 2.8  0.3 y 3/ 0.0 1/ 0.0  0.3  -15° 1/ 0° +15° 1/ 0°  5° Cap W3x16q in accordance with IEC Publication 60061 (sheet 7004-106-3) Electrical and photometric characteristics Volts 12 12 Rated values Watts 21 …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the major filament is seen on the screen on which the image of the filament is projected. The end view of that filament shall be obtained within the angular displacement tolerance limits (±15°).
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the major filament seen end-on:
2.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament;
2.2.deleted
The projection of the minor filament shall lie entirely within a rectangle of width "c" and height "d" having its centre at a distance "u" above the theoretical position of the centre of the major filament.
3.deleted
The filament lamp being placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to axis of the major filament:
3.1.deleted
The projection of the major filament shall lie entirely within a rectangle of height "a" and width "h", centred on the theoretical position of the centre of the filament;
3.2.deleted
The centre of the major filament shall not be offset by more than distance "k" from the reference axis;
3.3.deleted
The centre of the minor filament axis shall not be offset from the reference axis by more than 2 mm (0.4 mm for standard filament lamps). Annex 1 Category W21/5W Sheet W21/5W/3 Reference a b c d u Dimension 3.5 3.0 4.8 2.8 Reference a h k Dimension 3.5 9.5 1.0 Categories WP21W and WPY21W Sheet WP21W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. e 27.9 3/ 27.9  0.3 f 5.5 6.0 7.0 6.0  0.5 2/ 3/ Lateral deviation 0.0  0.4 3/ 3/  75° …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits.
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis. Category WR21/5W Sheet WR21/5W/1 The drawings are intended only to illustrate the essential dimensions (in mm) of the filament lamp a = major (high wattage) filament b = minor (low wattage) filament Filament lamps of normal production Standard filament lamp Dimensions in mm min. nom. max. 1/ e 25.0 25.0  0.3 f 7.5 7.5 + 0 / -2 2/ 1/ Lateral deviation 0.3 max. 3/ 1/ x 2.8 2.8  0.3 y 3/ 0.0 1/ 0.0  0.3 1/ 1/  -15° …
1.deleted
The filament lamp is placed in a holder capable of being rotated about its axis and having either a calibrated scale or fixed stops corresponding to the angular displacement tolerance limits, i.e. 15°. The holder is then so rotated that an end view of the filament is seen on the screen on to which the image of the filament is projected. The end view of the filament shall be obtained within the angular displacements tolerance limits (15°).
2.deleted
The filament lamp placed with the cap down, the reference axis vertical and the filament seen end-on, the projection of the filament shall lie entirely within a rectangle of height "a" and width "b", having its centre at the theoretical position of the centre of the filament.
3.deleted
The filament lamp placed with the cap down and the reference axis vertical, the filament lamp being viewed in a direction at right angles to the filament axis:
3.1.deleted
The projection of the filament shall lie entirely within a rectangle of height "a" and width "h", having its centre at the theoretical position of the centre of the filament.
3.2.deleted
The centre of the filament shall not be offset by more than distance "k" from the reference axis.
12.deleted
Approval granted/refused/extended/withdrawn2: