I. Specific equipment of vehicles of category M and N using liquefied petroleum gases in their propulsion system II. Vehicles of category M and N fitted with specific equipment for the use of liquefied petroleum gases in their propulsion system with regard to the installation of such equipment
Supplement 10 to the 01 series → latestSupplement 14 to the 01 series → latest02 series of amendments → latest03 series of amendments → latest
1.1.changed
Part I Approval of specific equipment of vehicles of category M and N1 N 1 using liquefied petroleum gases in their propulsion system;
2.changed
LPG components for use in vehicles shall be classified with regard to the maximum operating pressure and function, according to Figure 1. Class 0 High pressure parts including tubes and fittings containing liquid LPG with a pressure > 3,000 kPa. Class 1 High pressure parts including tubes and fittings containing liquid LPG at vapour pressure or increased vapour pressure up to 3,000 kPa. Class 2 Low pressure parts including tubes and fittings containing vaporized LPG with a maximum operating pressure below 450 kPa and over 20 kPa above atmospheric pressure. Class 2A Low pressure parts for a limited pressure range including tubes and fittings containing vaporized LPG with a maximum operating pressure below 120 kPa and over 20 kPa above atmospheric pressure. Class 3 Shut-off valves and pressure relief valves, when operating in the liquid phase. LPG components designed for a maximum operating pressure below 20 kPa above atmospheric pressure are not subjected to this Regulation. A component can consist of several parts, each part classified in his own class with regard to maximum operating pressure and function. 1 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2 https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
Figure 1changed
Start Yes Operating pressure > 3 MPa? No Yes Yes Maximum operating Safety pressure Safety > valves? 450kPa? valves? No No Yes Maximum operating pressure < 20kPa? No Not subjected to this regulation. Yes Maximum operation pressure < 120kPa? No Or Class 2 Class 2A Class 1 Class3 Class 0 STOP
5.2.changed
An approval number shall be assigned to each type of equipment approved. Its first two digits "(at present 02 corresponding to the 02 series of amendments) shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue approved in accordance with Schedule 4 of the approval. The same Contracting Party shall not assign this alphanumeric code to another type of equipment. Agreement (E/ECE/TRANS/505/Rev.3).
5.4.deleted
4.2.added
above, to all equipment conforming to a type approved under this
Regulation, in addition to the mark prescribed in paragraphs 4.1. and 4.3.
above, an international approval mark consisting of:
5.4.2.changed
The number of this Regulation, followed by the letter "R", a dash and the 2 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.6. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions approval number to the right of the circle prescribed in paragraph 5.4.1. above. This approval number consists of the component type approval number which appears on the certificate completed for this type (see paragraph 5.2. above and Annex 2B) preceded by two figures indicating the sequence of the latest series of amendments to this Regulation.
6.3.1.changed
The container shall be equipped with the following accessories, which may be either separate or combined (multivalve(s)): 2 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.6. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
6.7.deleted
6.9.changed
Gas injection devices/Gas mixing piece piece3 11 or Injectors
6.16.changed
Multi-component Annexes applicable to the single components 1 Either combined or separate 2 Only applicable when the gas dosage actuator is not integrated in the gas injection device. 3 Applicable only when the operating pressure of the gas mixing piece exceeds 20 kPa (Class 2).
6.17.2.changed
Electrical operated devices containing LPG shall, in order to prevent in case of fracture of the component electric sparks on the surface of fracture: (a) Be insulated in a manner that no current is lead through LPG containing parts; (b) Have the electrical system of the device isolated: (i) From the body; (ii) From the container for the fuel pump. Isolation resistance shall be > 10 M.
6.17.8.3.changed
The flow capacity of the pressure relief valve, determined with compressed air at a pressure which is 20 per cent higher than the normal operating- pressure operating-pressure shall be at least Q 10.66 A0.82 In which: Q= flow of air in standard m3/min (100 kPa absolute and temperature of 15 °C) A= exterior surface of the container in m2. The flow test results shall be corrected to standard conditions: Air pressure of 100 kPa absolute and temperature of 15 °C. When the pressure relief valve is considered as a pressure relief device, the flow shall be at least 17.7 standard m3/min.
6.17.10.4.changed
The filling unit shown in Figure 4 may also apply for motor vehicles of categories M2, M3, N2, N3 and M1 having a maximum total mass > 3,500 kg.3 3 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
6.17.10.6.added
Specific provisions regarding the K15 filling unit (Annex 9 – Figure 3):
6.17.10.6.2.changed
The flow through the connector at a pressure difference of 30 kPa shall be at As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions least 60 litres/min, if tested with water.
6.17.10.8.added
The J15, K15 and heavy-duty vehicle Euro filling units shall comply with the
impact test as described in Annex 9, paragraph 7.
6.17.12.2.changed
The gas-tight housing shall be leak-proof at a pressure of 10 kPa with the aperture(s) closed off, maximum allowed leak rate of 100 cm3/h cm 3/h vapour and show no permanent deformation.
6.17.13.2.3.changed
The excess flow valve shall cut off at a pressure difference over the valve of 90 kPa. At this pressure difference the flow shall not exceed 8,000 cm3/min. cm 3/min.
6.17.14.1.changed
When a non-return valve is intended to be fitted as a component of an interconnected LPG-system for the purpose of paragraph 17.13.1.1., 17.13.1.2. or 17.13.2.1., it shall be submitted, during approval, to an endurance test according to paragraph 9.7. of Annex 16. The valve shall bear a marking with the following data clearly legible and indelible: (a) The wording "ICS", and (b) The approval mark according to paragraph 5.4. of this Regulation.
17.13.1.2.deleted
11.6.added
As from 1 September 2022, Contracting Parties applying this Regulation may
refuse the sale of a type of component which does not meet the requirements
of the 02 series of amendments to this Regulation, unless the component is
intended as a replacement for fitting on vehicles in use.
16.2.changed
An approval number shall be assigned to each type of vehicle approved. Its first two digits shall indicate the series of amendments incorporating the most recent major technical amendments made to the Regulation at the time of issue approved in accordance with Schedule 4 of the approval. Agreement (E/ECE/TRANS/505/Rev.3).
16.4.1.changed
A circle surrounding the letter "E" followed by the distinguishing number of the country which has granted approval.4 4 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document
16.5.changed
Regulations annexed to the Agreement, in the country which has granted approval under this Regulation, the symbol prescribed in paragraph 16.4.1. above need not be repeated; in such case, the Regulation and approval numbers and the additional symbols of all the Regulations under which approval has 4 The distinguish numbers of the Contracting Parties to the 1958 Agreement are reproduced in Annex 3 to the Consolidated Resolution on the Construction of Vehicles (R.E.3), document ECE/TRANS/WP.29/78/Rev.6 https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions been granted in the country which has granted approval under this Regulation shall be placed in vertical columns to the right of the symbol prescribed in paragraph 16.4.1. above.
17.1.5.changed
The LPG system shall show no leaks. ECE/TRANS/WP.29/78/Rev.6 https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
17.1.6.1.changed
Notwithstanding the provisions of paragraph 17.1.6., it shall be possible to make an external inspection (e.g. for periodic technical inspection) of the LPG-container LPG- container and its accessories, when located outside the vehicle, according to the specifications of the manufacturer, without the use of tools to dismantle, but with visual aids, e.g. lamps, mirrors or endoscopes.
17.1.7.2.changed
The heating system referred to in paragraph 17.1.7.1. above shall be permitted if, in the view of the Technical Services responsible for conducting type approval, the heating system is adequately protected and the required operation 5 As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions of the normal LPG system is not affected.
17.1.8.deleted
17.1.8.1.deleted
17.1.8.2.changed
17.2.2.deleted
17.2.1.changed
No component of the LPG system, including any protective materials which form part of such components, shall project beyond the external surface of the vehicle, with the exception of the filling unit if this does not project more than 10 mm beyond the nominal line of the body panel. As defined in the Consolidated Resolution on the Construction of Vehicles (R.E.3.), document ECE/TRANS/WP.29/78/Rev.6, para. 2. https://unece.org/transport/standards/transport/vehicle-regulations-wp29/resolutions
17.2.2.added
With the exception of the LPG fuel container, in no cross section of the vehicle
any component of the LPG system, including any protective material which
forms part of such components, may extend beyond the lower edge of the
vehicle unless another part of the vehicle, within a radius of 150 mm is situated
lower.
17.3.1.10.changed
Gas-carrying connections between the LPG system components; 6 These components might not be necessary in case of liquid LPG injection.
17.3.2.11.changed
Fuel rail. These components might not be necessary in case of liquid LPG injection.
17.7.2.deleted
17.7.10.changed
17.11.4.changed
Electrical cables shall be adequately protected against damage. The electrical connections inside the boot and passengers compartment shall comply with protection degree class IP 40 according to IEC Standard 60529-1989+A1:1999. 60529- 1989+A1:1999. All other electrical connections shall comply with protection degree class IP 54 according to IEC Standard 60529- 1989+A1:1999. 60529-1989+A1:1999.
17.13.1.1.changed
Means shall be provided to prevent any flow of LPG into the diesel tank. The installation of two non-return valves along the flow line shall be considered as meeting this requirement if the valves comply with the provisions of paragraph 6.17.14.1.
17.13.2.1.changed
Means shall be provided to prevent any flow of LPG into the petrol tank. The installation of two non-return valves along the flow line shall be considered as meeting this requirement if the valves comply with the provisions of paragraph 6.17.14.1.
22.14.added
As from the official date of entry into force of the 03 series of amendments,
no Contracting Party applying this Regulation shall refuse to grant or refuse
to accept type approvals under this Regulation as amended by the 03 series of
amendments.
22.15.added
As from 1 September 2021, Contracting Parties applying this Regulation
shall not be obliged to accept type approvals to the preceding series of
amendments, first issued after 1 September 2021.
22.16.added
Until 1 September 2022, Contracting Parties applying this Regulation shall
accept type approvals to the preceding series of amendments, first issued
before 1 September 2021.
22.17.added
As from 1 September 2022, Contracting Parties applying this Regulation
shall not be obliged to accept type approvals issued to the preceding series of
amendments to this Regulation.
22.18.added
Regulation shall continue to accept UN type-approvals issued according to the
preceding series of amendments to the UN Regulation, for the vehicles /
vehicle systems / vehicle components which are not affected by the changes
introduced by the 03 series of amendments.
22.19.added
As from the official date of entry into force of the 04 series of amendments,
no Contracting Party applying this Regulation shall refuse to grant or refuse
to accept type approvals under this Regulation as amended by the 03 series of
amendments.
22.20.added
As from 1 September 2023, Contracting Parties applying this Regulation
shall not be obliged to accept type approvals to the preceding series of
amendments, first issued after 1 September 2023.
22.21.added
Until 1 September 2025, Contracting Parties applying this Regulation shall
accept type approvals to the preceding series of amendments, first issued
before 1 September 2023.
22.22.added
As from 1 September 2025, Contracting Parties applying this Regulation
shall not be obliged to accept type approvals issued to the preceding series of
amendments to this Regulation.
22.23.added
Regulation shall continue to accept UN type-approvals issued according to the
preceding series of amendments to the UN Regulation, for the vehicles /
vehicle systems / vehicle components which are not affected by the changes
introduced by the 04 series of amendments.
1.2.4.5.2.10.changed
Other adjustment possibilities: if so and which (description and drawings): Annex 1
1.2.4.5.3.added
1 Specify the tolerance.
2 Strike out what does not apply.
1.2.4.5.7.changed
LPG container: 1 Specify the tolerance. Strike out what does not apply.
1.2.4.5.8.7.changed
Gas-tight housing: Annex 1
1.2.5.deleted
12.deleted
1.2.7.changed
1.changed
Container including the configuration of accessories fitted to the container, as laid down in Appendix 1 to this annex. 80 per cent stop valve Level indicator Pressure relief valve (discharge valve) Pressure relief device Remotely controlled service valve with excess flow valve Gas-tight housing Power supply bushing (pump/actuators) Fuel pump Vaporizer/pressure regulator Shut-off valve Non-return valve Gas-tube pressure relief valve Service coupling Flexible hose Remote filling unit 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation.) 2 Strike out what does not apply. Annex 2B Gas-tube pressure relief valve Service coupling Flexible hose Remote filling unit Gas injection device or injector Fuel rail Gas dosage unit Gas mixing piece Electronic control unit Pressure/temperature sensor LPG filter unit Non-seamless gas tubes and their couplings Gas tubes made of materials other than copper, stainless steel and steel with corrosion- resistant coating and their couplings Multi-component
14.changed
The documents filed with the application or extension of approval can be obtained upon request. Annex 2B - Appendix Annex 2B - Appendix Containers only
2.changed
The lists of the container family indicate the diameter, capacity, external surface and the possible configuration(s) of the accessories fitted to the container. Annex 2B - Appendix
Table 3changed
No. Accessories Type Approval No. Extension Configuration of No. accessories [code] a b c d Annex 2C Annex 2C Arrangement of approval marks Model A (See paragraph 16.4. of this Regulation) 67 R—022439 R—032439 a 8 mm The above approval mark affixed to a vehicle shows that the vehicle has, with regard to the installation of specific equipment for the use of LPG for propulsion, been approved in the Netherlands (E 4), pursuant to Regulation No. 67 under approval number 022439. 032439. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of Regulation No. 67 as amended by the 02 03 series of amendments. Model B (See paragraph 16.4. of this Regulation) 67 022439 032439 83 041628 a 8 mm The above approval mark affixed to a vehicle shows that the vehicle has, with regard to the installation of specific equipment for the use of LPG for propulsion, been approved in the Netherlands (E 4), pursuant to Regulation No. 67 under approval number 022439. 032439. The first two digits of the approval number indicate that the approval was granted in accordance with the requirements of Regulation No. 67 as amended by the 02 03 series of amendments and that Regulation No. 83 included the 04 series of amendments. Annex 2D Annex 2D Communication (Maximum format: A4 (210 x 297 mm)) issued by : Name of administration: Concerning:2 Approval granted Approval extended Approval refused Approval withdrawn Production definitively discontinued of a vehicle type with regard to the installation of LPG systems pursuant to Regulation No. 67
17.changed
The following documents filed with the application or extension of approval can be obtained upon request. 1 Distinguishing number of the country which has granted/extended/refused/withdrawn approval (see approval provisions in the Regulation.) 2 Strike out what does not apply. Drawings, diagrams and scheme plans regarding the components and the installation of the LPG equipment considered to be of importance for the purpose of this Regulation; Where applicable drawings of the various equipment and their position in the vehicle. Annex 3
3.added
Pressure relief valve (discharge valve) and components connecting the
pressure relief valve with the gaseous phase inside the LPG container
3.6.changed
Applicable test procedures: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. Seat leakage Annex 16, para. 8. Endurance Annex 16, para. 9. (with 200 operation cycles) Annex 3 Operational test Annex 16, para. 10. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Resistance to dry heat Annex 16, para. 13.** Ozone ageing Annex 16, para. 14.** Creep Annex 16, para. 15.** Temperature cycle Annex 16, para. 1.6.** 16.** Test on non-metallic material inside a container Annex 16, para. 18.**
4.2.changed
5.6.changed
Applicable test procedures: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Resistance to dry heat Annex 16, para. 13.** Ozone ageing Annex 16, para. 14.** Creep Annex 16, para. 15.** Temperature cycle Annex 16, para. 16.** Annex 3
7.added
Provisions regarding the approval of the pressure relief device (fuse) and
components connecting the pressure relief device with the gaseous phase
inside the LPG container.
7.6.changed
Test procedures to be applied: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. Seat (if any) leakage Annex 16, para. 8. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Resistance to dry heat Annex 16, para. 13.** Ozone ageing Annex 16, para. 14.** Creep Annex 16, para. 15.** Temperature cycles Annex 16, para. 16.** Test on non-metallic material inside a container Annex 16, para. 18.**
7.7.changed
Pressure relief device (fuse) specified by the manufacturer shall be shown to be compatible with the service conditions by means of the following tests: (a) One specimen shall be held at a controlled temperature of not less than 90 °C and a pressure not less than test pressure (3,000 kPa) for 24 hours. At the end of this test there shall be no leakage or visible sign of extrusion of any fusible metal used in the design. (b) One specimen shall be fatigue tested at a pressure cycling rate not to exceed 4 cycles per minute as follows: (i) Held at 82 °C while pressured for 10,000 cycles between 300 and 3,000 kPa; (ii) Held at -20 °C while pressured for 10,000 cycles between 300 and 3,000 kPa. At the end of this test there shall be no leakage, or any visible sign of extrusion of any fusible metal used in the design. (c) Exposed brass pressure retaining components of pressure relief device shall withstand, without stress corrosion cracking, a mercurous nitrate test as described in ASTM B154***. The pressure relief device shall be immersed for 30 minutes in an aqueous mercurous nitrate solution containing 10 g of mercurous nitrate and 10 ml of nitric acid per litre of solution. Following the immersion, the pressure relief device shall be leak tested by applying an aerostatic pressure of 3,000 kPa for one minute during which time the component shall be checked for external leakage. Any leakage shall not exceed 200 cm3/h. (d) Exposed stainless steel pressure retaining components of pressure relief device shall be made of an alloy type resistant to chloride induced stress corrosion cracking. ___________ * Only for metallic parts. ** Only for non-metallic parts. *** This procedure, or other equivalent, is allowed until an international standard will be available. Annex 4
6.2.changed
For parts of Class 2 and/or 2A: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.** _________________ * Only for metallic parts. ** Only for non-metallic parts. Annex 6
6.2.changed
For parts of Class 2 and/or 2A: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Remarks: The shut-off valve can be integrated in the vaporizer, regulator, in this case Annex 7 is also applicable. The parts of the pressure regulator/vaporizer (Class 1, 2 or 2A) shall be leak proof with the outlet(s) of that part closed off. For the overpressure test all the outlets including those of the coolant compartment shall be closed off. __________________ * Only for metallic parts. ** Only for non-metallic parts. Annex 7
1.7.changed
If the remotely controlled shut-off valve is closed during commanded stop phases, the valve shall be submitted to the numbers of operations according to paragraph 4.7. of Annex 3 during the endurance test of paragraph 9. of Annex 16.
3.5.changed
General design rules: Paragraph 6.15.2., Provisions regarding the electrical insulation. Paragraph 6.15.3.1., Provisions on valves activated by electrical power. Annex 7 Paragraph 6.15.7., Provisions regarding the gas-tube pressure relief valve.
4.6.changed
Applicable test procedures: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. Seat leakage Annex 16, para. 8. Endurance Annex 16, para. 9. (with 6,000 operation cycles) LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Resistance to dry heat Annex 16, para. 13.** Ozone ageing Annex 16, para. 14.** Creep Annex 16, para. 15.** Temperature cycle Annex 16, para. 16.** __________________ * Only for metallic parts. ** Only for non-metallic parts. Annex 8
1.1.3.changed
The inside diameter shall be in compliance with Table 1 of standard ISO 1307.
1.4.2.deleted
1.5.4.1.changed
3,000 times the hereafter prescribed alternating-bending-test without breaking. After the test the hose shall be capable of withstanding the test- pressure test-pressure as mentioned in paragraph 1.5.5.2. below.
1.6.2.3.changed
The couplings can be made as swivel-nut type or as quick-connector type. Annex 8
1.7.1.changed
The construction of the couplings shall be such, that it is not necessary to peel the cover unless the reinforcement of the hose consists of corrosion- resistant corrosion-resistant material.
2.4.1.3.changed
Resistance to ageing according to ISO 188 with the following conditions: Annex 8 (a) Temperature: 115 °C (test temperature = maximum operating temperature minus 10 °C); (b) Exposure period: 336 hours. Requirements: (a) Maximum change in tensile strength 25 per cent; (b) Maximum change in elongation at break -30 per cent and +10 per cent.
2.5.4.3.changed
The burst pressure shall not be less than 1,800 kPa. Annex 8
2.7.2.changed
The construction of the couplings shall be such, that it is not necessary to peel the cover unless the reinforcement of the hose consists of corrosion- resistant corrosion-resistant material.
3.1.5.changed
The inside diameter shall be in compliance with Table 1 of standard ISO 1307.
3.3.1.2.changed
Resistance to n-pentane according to ISO 1817 with the following conditions: (a) Medium: n-pentane; (b) Temperature: 23 °C (tolerance acc. to ISO 1817); (c) Immersion period: 72 hours. Requirements: (a) Maximum change in volume 20 per cent; (b) Maximum change in tensile strength 25 per cent; (c) Maximum change in elongation at break 30 per cent. After storage in air with a temperature of 40 °C for a period of 48 hours the mass compared to the original value may not decrease more than 5 per cent. Annex 8
3.4.3.1.changed
Tensile strength and elongation at break according to ISO 527-2 with the following conditions: (a) Specimen type: type 1 BA; (b) Tensile speed: 20 mm/min. The material has to be conditioned for at least 21 days at 23 °C and 50 per cent relative humidity prior to testing. Requirements: (a) Tensile strength not less than 20 MPa; Annex 8 (b) Elongation at break not less than 100 per cent.
Figure 3changed
b mass propulsion mechanism a 1,2m ( (a ((a = 102 mm; b= 241 mm)
3.5.5.3.changed
The burst pressure shall not be less than 10,000 kPa. Annex 8
3.6.2.changed
The couplings shall be of the crimp-fitting type and made up of a hose- coupling hose-coupling or banjo bolt. The sealing shall be resistant to LPG and comply with paragraph 3.3.1.2. above.
4.1.5.changed
The inside diameter shall be in compliance with Table 1 of standard ISO 1307.
4.3.2.1.changed
Tensile strength and elongation at break according to ISO 527-2 with the following conditions: (a) Specimen type: type 1 BA; (b) Tensile speed: 20 mm/min. The material has to be conditioned for at least 21 days at 23 °C and 50 per cent relative humidity prior to testing. Annex 8 Requirements: (a) Tensile strength not less than 20 MPa; (b) Elongation at break not less than 50 per cent.
4.4.3.3.changed
Resistance to ageing according to ISO 188 with the following conditions: (a) Temperature: 115 °C (test temperature = maximum operating temperature minus 10 °C); (b) Exposure period: 24 and 336 hours. After ageing the specimens have to be conditioned for at least 21 days before carrying out the tensile test according to paragraph 4.3.1.1. above. Requirements: Annex 8 (a) Maximum change in tensile strength 20 per cent after 336 hours ageing compared to the tensile strength of the 24 hours aged material; (b) Maximum change in elongation at break 50 per cent after 336 hours ageing compared to the elongation at break of the 24 hours aged material.
4.7.deleted
4.6.2.changed
The couplings shall be of the crimp-fitting type and made up of a hose- coupling hose-coupling or banjo bolt. The sealing shall be resistant to LPG and comply with paragraph 4.3.1.2. above.
4.3.1.2.added
above.
Figure 3deleted
7.added
Impact test requirements for the J15, K15 and heavy-duty vehicle Euro filling
units
7.1.changed
The filling unit shall be subjected to an impact test of 10 J. Annex 9
Figure 5changed
Dimensions in millimetres Keys: 1 Nozzle sealing surface 2 Minimum valve travel 3 General tolerance ________________ * Only for metallic parts. ** Only for-non-metallic parts. Annex 10
Annex 10changed
The meaning of symbols and terms used in this annex Ph = hydraulic test pressure in kPa; Pr = container bursting pressure measured in the bursting test, in kPa; Re = minimum yield stress in N/mm2 guaranteed by the material standard; Rm = minimum tensile strength in N/mm2 guaranteed by the material standard Rmt = actual tensile strength, in N/mm2; a = calculated minimum thickness of the cylindrical shell wall, in mm; b = calculated minimum thickness of dished ends, in mm; D = nominal outside diameter of the container, in mm; R = inside radius of the dished end of the standard cylindrical container, in mm; r = inside knuckle of the dished end of the standard cylindrical container, in mm; H = outside height of dished part of container end, in mm; h = height of cylindrical part of dished end, in mm; L = length of container's stress-resistant shell, in mm; A = elongation value (per cent) of parent material; V0 = initial volume of the container at the moment when the pressure is increased in the burst test, in dm3; V = final volume of the container on bursting, in dm3; dm 3; g = gravity, in m/s2; c = shape factor; Z = stress reduction factor.
1.5.2.changed
Those parts of a container having been deformed by more than 5 per cent shall be submitted to the following heat treatment: normalize. Annex 10
1.6.1.1.1.changed
Containers without longitudinal welds: Ph D Ph D a R a= = 2000 e + Ph 1500 R e + Ph R 4/3
1.6.1.1.2.changed
Containers with longitudinal welds: Ph D Ph D a Re a= = 2000 e z + Ph 1500 R e z + Ph R 4/3 (a) z = 0.85 where the manufacturer radiographs each weld intersection and 100 m of the adjacent longitudinal weld and 50 mm (25 mm each side of the intersection) of the adjacent circumferential weld. This test has to be performed per machine at the beginning and end of each work shift period from continuous production. (b) z = 1 where each weld intersection and 100 mm of the adjacent longitudinal weld and 50 mm (25 each side of the intersection) of the adjacent circumferential weld is spot radiographed. This test has to be performed at 10 per cent of the container production: the containers to be tested are chosen randomly. Should these radiograph tests reveal unacceptable defects, as defined in paragraph 2.4.1.4. of this annex, all the necessary steps shall be taken to examine the production run in question and eliminate the defects.
2.4.1.4.changed
1.6.1.2.3.changed
The thickness of these barrelled ends shall not be in toto less than the figure calculated by means of the following formula: Ph D b b= C 1500 R e The shape factor C to be used for full ends is given in the table and in the graphs contained in Appendix 4 to this annex. The wall thickness of the cylindrical edge of the ends may not be less or differ more than 15 per cent from the smallest wall thickness of the shell.
1.6.1.3.changed
The nominal wall thickness of the cylindrical part and of the barrelled end may not, under any circumstances; be less than: D + 1 mm with a minimum of 1.5 mm.
1.6.2.changed
The stresses in the container shall be calculated for each container type. The pressures used for these calculations shall be the design pressure and burst test pressure. The calculations shall use suitable analysis techniques to establish stress distribution throughout the container. Annex 10
2.changed
Tables 1 and 2 below give an overview of the tests to be performed on the LPG containers on prototypes as well as during the production process according to their nature. All tests shall be performed at ambient temperature of 20 °C 5 °C, unless otherwise stated. Annex 10
2.1.1.1.1.changed
The frequency of the tests for metal containers shall be: 1 container from each batch during production and for type testing, see Table 1. Test pieces which are not flat shall be flattened by a cold process. In test pieces containing a weld, the weld shall be machined to trim the surplus. Metal containers shall be subjected to the tests as described in Table 1. Test pieces from containers with one circumferential weld only (two sections) shall be taken from the places shown in Appendix 2, Figure 1. Test pieces from containers with longitudinal and circumferential welds (three or more sections) shall be taken from the places shown in Appendix 2, Figure
2.1.2.1.1.changed
Containers with longitudinal and circumferential welds (three sections) on test-pieces test- pieces taken from the places shown in Figure 1 of Appendix 2 to this annex: (a) One tensile test on parent material; the test piece to be taken in the longitudinal direction (if this is not possible, it may be taken in a circumferential direction); (b) One tensile test on parent material of the bottom; (c) One tensile test perpendicular to the longitudinal weld; (d) One tensile test perpendicular to the circumferential weld; (e) One bend test on the longitudinal weld, the inner surface in tension; (f) One bend test on the longitudinal weld, the outer surface in tension; (g) One bend test on the circumferential weld, the inner surface in tension; (h) One bend test on the circumferential weld, the outer surface in tension; and (i) One macroscopic test of a welded section; (ml, m2) A minimum of two macroscopic tests of valve boss/plate sections in case of the sidewall mounted valves referred to in paragraph 2.4.2. below. Annex 10
2.1.2.2.1.1.changed
2.1.2.3.1.changed
The bend test shall be carried out in accordance with standards ISO 7438:2005 and ISO 7799:1985 and ISO 5173:2009 + Amd 1:2011 for welded parts. The bend tests shall be carried out on the inner surface in tension and the outer surface in tension.
2.2.3.3.2.changed
For metal containers the fracture shall not reveal an inherent defect in the metal. The weld shall be at least as strong as the original metal but preferably stronger. For all-composite containers, the fracture shall not reveal any defects in the structure. Annex 10
2.3.6.3.3.changed
Retesting is permitted for the external leak test. A second test shall be performed on two containers which have been produced successively to the first container within the same batch. Annex 10 If the results of these tests are satisfactory, the first test shall be ignored. In the event where one or both of the retests fail to meet the requirements, the batch shall be rejected.
2.4.1.1.changed
Welds shall be radiographed in compliance with ISO specification R 1106, using classification B. Annex 10
2.4.1.4.changed
2.4.1.4.2.added
For the container wall thickness < 4 mm, the inclusions listed below are
regarded as acceptable:
Any gas inclusion measuring not more than a/2 mm;
Any gas inclusion measuring more than a/2 mm but not more than a/1.5 mm,
which is more than 25 mm away from other gas inclusion measuring more than
a/2 mm and measuring not more than a/1.5 mm;
Any elongated inclusion or any group of rounded inclusions in a row where
the length represented (over a weld length of 12a) is not greater than 6 mm;
Gas inclusions over any 100 mm weld length, where the total area of all the
figures is not greater than 2a mm2.
2.6.2.changed
Container set-up (a) The container shall be placed in the designed position by the manufacturer with the container bottom approximately 100 mm above the fire source. (b) Shielding shall be used to prevent direct flame impingement on the fusible plug (PRD) if present. The shielding shall not be in direct contact with the fusible plug (PRD). (c) Any failure during the test of a valve, fitting or tubing that is not part of the intended protection system for the design shall invalidate the result. (d) Containers with a length of less than 1.65 m. The center of the container shall be positioned over the center of the fire source. 1 Additional accessories, modifications and extensions of the accessories fitted to the container is possible without retesting, if notified to the Type Approval Authority which approved the container, considered to be unlikely to have an appreciable adverse effect. The Type Approval Authority may require a further test report from the Technical Service responsible. The container and its configurations of accessories will be indicated in the appendix to Annex 2B. Multivalve or, when approved separately, pressure relief valve (discharge valve) and pressure relief device, extended for technical modifications and marked in accordance to Annex 2A need to have a new bonfire test. The container and its configurations of accessories will be indicated in the appendix to Annex 2B. Annex 10 (e) Containers with a length equal to or larger than 1.65 m. If the container is fitted with a pressure relief device at one side, the fire source shall commence at the opposite side of the container. If the container is fitted with pressure relief devices at both sides, or at more than one location along the length of the container, the center of the fire source shall be centered midway between the pressure relief devices that are separated by the greatest horizontal distance.
2.7.2.changed
For this test, the fluid medium shall be water/glycol mixture or another liquid having a low freezing point which does not change the properties of the container material. A container filled with the fluid medium to the weight that equals the filling with 80 per cent of LPG with a reference mass of 0.568 kg/l, is projected, parallel to the length axle (x-axis in Figure 1) of the vehicle in which it is intended to be fitted at a velocity, V of 50 km/h, against a solid wedge, fixed horizontally, perpendicular to the movement of the container. The wedge shall be installed so that the centre of gravity (c.g.) of the container hits the centre of the wedge. The wedge shall have an angle α of 90 degrees and the point of impact shall be rounded with a maximum radius of 2.5 mm. Annex 10 The length of the wedge L, shall be at least equal to the width of the container in respect to its movement during the test. The height H of the wedge shall be at least 600 millimetres.
Figure 2deleted
Figure 4deleted
2.10.1.changed
A finished container shall be exposed for 100 hours to a 30 per cent sulphuric acid solution (battery acid with specific gravity of 1.219) while pressurized to 3,000 kPa. During the test, a minimum of 20 per cent of the total area of the container has to be covered by the sulphuric acid solution. Then, the container shall be submitted to a burst test as defined in paragraph 2.2. of this annex. Annex 10
Annex 10 - Appendix 5deleted
Figure 2bchanged
Containers with circumferential welds only and valve boss/plate fitted to the end. (m1, m2) Macro sections through valve boss/plate welds (Refer to Figure 2a for other locations of test-pieces) Annex 10 – Appendix 3
Annex 10 - Appendix 4changed
6.changed
The glass transition temperature (Tg) of an elastomer component shall be lower than -40 °C. The glass transition temperature shall be tested according ISO 6721 "Plastics - Determination of dynamic mechanical properties". The Tg-onset Tg- onset is derived from the plotted diagram storage modulus versus temperature by determining the temperature, where the two tangents, which are representing the slopes of the diagram before and after the dramatic loss of stiffness, intersects. Annex 11
3.5.deleted
6.changed
Applicable test procedures: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* Remarks: The parts of the gas dosage unit (Class 2 or 2A) shall be leakproof with the outlet(s) of that part closed. For the overpressure test all the outlets including those of the coolant compartment shall be closed off. * Only for metallic parts. ** Only for non-metallic parts. Annex 13
6.2.changed
For parts of Class 2 or 2A: Overpressure test Annex 16, para. 4. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.* __________________ * Only for metallic parts. ** Only for non-metallic parts. Annex 14
6.4.changed
The ECU shall bear a marking with the following data clearly legible and indelible: (a) the wording "ICS"; and (b) the value of 0.4 litre; and (c) the approval mark according to paragraph 5.4. of this Regulation. Annex 15 Provisions regarding the approval of gas tube(s) of non- seamless type, gas tube(s) made of materials other than copper, stainless steel, and steel with corrosion-resistant coating, and their couplings
6.2.changed
For parts of Class 2 or 2A: Overpressure test Annex 16, para. 4. 1 Only for metallic parts. External leakage Annex 16, para. 5. High temperature Annex 16, para. 6. Low temperature Annex 16, para. 7. LPG compatibility Annex 16, para. 11.** Corrosion resistance Annex 16, para. 12.2
6.3.2.changed
Test the gas tube according to the following procedure and acceptance criteria. (a) Select a mandrel with an external diameter from the below table: External diameter Mandrel diameter ≤ 8 mm 3 times the external gas tube diameter > 8 mm 5 times the external gas tube diameter (b) Bend the gas tube over this mandrel once, forming a "U" shape. (c) Close the ends of the gas tube and subject it to the overpressure test according to Annex 16, paragraph 4. At the completion of the overpressure test, the gas tube shall be tested according to the leakage test of Annex 16, paragraphs 5., 6. and 7. Only for metallic parts. 2 Only for metallic parts. ** Only for non-metallic parts. Annex 15
6.3.4.changed
Vibrate the gas tube and its coupling(s) according to the test described in Annex 16, paragraph 10.5.4., procedure A. After this test the gas tube and its coupling(s) need to comply with the leakage test of Annex 16, paragraphs 5., 6. and 7. and with the overpressure test according to Annex 16, paragraph 4. 2 Only for metallic parts. ** Only for non-metallic parts.
3.3.changed
All test values shall indicate the type of test medium used, if applicable. Annex 16
4.changed
A LPG containing component shall withstand without any visible evidence of rupture or permanent distortion a hydraulic test pressure which is determined by Table 1 (of 2.25 times the maximum classification pressure) during minimal 1 minute with the outlet of the high pressure part plugged. The samples, previously subjected to the durability test of paragraph 9. of this annex are to be connected to a source of hydrostatic pressure. A positive shut-off shut- off valve and a pressure gauge, having a pressure range of not less than 1.5 times nor more than 2 times the test pressure, are to be installed in the hydrostatic pressure supply piping.
Table 3changed
Classification pressure Test pressure for leakage test Classification of component [kPa] [kPa] Class 0 WP 1.5 WP Class 1 3,000 4,500 Class 2A 120 180 Class 2 450 675 Classification pressure Test pressure for leakage test Classification of component [kPa] [kPa] Class 3 3,000 6,750
6.changed
A LPG containing component shall not leak more than 15 cm3/hour cm 3/hour with the outlet plugged when submitted to a gas pressure at maximum operating temperature, as indicated in the annexes, equal to the leakage test pressure (Table 3, paragraph 5.3. above). The component shall be conditioned for at least 8 hours at this temperature.
7.changed
A LPG containing component shall not leak more than 15 cm3/hour cm 3/hour with the outlet plugged when submitted to a gas pressure, at the minimum operating temperature (-20 °C), equal to the leakage test pressure (Table 3, paragraph 5.3. above). The component shall be conditioned for at least 8 hours at this temperature.
8.1.changed
The following tests for seat leakage are to be conducted on samples of service valve or filling unit which have previously been subjected to the external leak test of paragraph 5. above. Annex 16
8.1.2.changed
Conformance with paragraphs 8.2. to 8.8. below is to be determined by connecting a length of tubing to the valve outlet. The open end of this outlet tube is to be located within an inverted graduated cylinder which is calibrated in cubic centimetres. The inverted cylinder is to be closed by a water seal. The apparatus is to be adjusted so that: (a) The end of the outlet tube is located approximately 13 mm above the water level within the inverted graduated cylinder, and (b) The water within and exterior to the graduated cylinder is at the same level. With these adjustments made, the water level within the graduated cylinder is to be recorded. With the valve in the closed position assumed as the result of normal operation, air or nitrogen at the specified test pressure is to be applied to the valve inlet for a test period of not less than 2 minutes. During this time, the vertical position of the graduated cylinder is to be adjusted, if necessary, to maintain the same water level within and exterior to it. At the end of the test period and with the water within and exterior to the graduated cylinder at the same level, the level of water within the graduated cylinder is again recorded. From the change of volume within the graduated cylinder, the leakage rate is to be calculated according to the following formula: 60 273 P V1 = Vt t T 101.6 Where: V1 = leakage rate, cubic centimetres of air or nitrogen per hour. Vt = increase in volume within graduated cylinder during test. t = time of test, minutes. P = barometric pressure during test, in kPa. T = ambient temperature during test, in K.
9.6.changed
The regulator shall be able to withstand 50,000 cycles without any failure when tested according to the following procedure: (a) Recycle the regulator for 95 per cent of the total number of cycles at room temperature and at the classification pressure. Each cycle shall consist of flow until stable outlet pressure has been obtained, after which the gas flow shall be shut off by a downstream valve within 1 s, until the downstream lock-up pressure has stabilized. Stabilized outlet pressures are defined as set pressure ±15 per cent for at least 5 s. Annex 16 (b) Cycle the inlet pressure of the regulator for 1 per cent of the total number of cycles at room temperature from 100 per cent to 50 per cent of the classification pressure. The duration of each cycle shall be no less than 10 s. (c) Repeat the cycling procedure listed in sub-paragraph (a) at 120 °C at the classification pressure for 1 per cent of the total number of cycles. (d) Repeat the cycling procedure listed in sub-paragraph (b) at 120 °C at the classification pressure for 1 per cent of the total number of cycles. (e) Repeat the cycling procedure listed in sub-paragraph (a) at -20 °C and 50 per cent of classification pressure for 1 per cent of the total number of cycles. (f) Repeat the cycling procedure listed in sub-paragraph (b) at -20 °C and 50 per cent of classification pressure for 1 per cent of the total number of cycles. (g) At the completion of all tests indicated in sub-paragraphs (a), (b), (c), (d), (e) and (f), the regulator shall be leak proof as described under external leakage test under paragraph 5. above, at the temperatures of -20 - 20 °C, at the room temperature and at the temperature of +120 °C.
10.1.2.3.changed
A pressure relief is to be connected to an air or other aerostatic supply source capable of being maintained at a pressure of at least 500 kPa effective pressure above the marked set pressure of the valve being tested. A positive shut-off valve and a pressure gauge having a pressure range of not less than 1.5 times nor more than 2 times the test pressure are to be installed in the pressure supply piping. The pressure gauge is to be installed in the piping between the valve being tested and the positive shut-off valve. Start-to- discharge Start-to-discharge and resealing pressure are to be observed through a water seal not over 100 mm in depth.
10.1.3.6.changed
The flowmeter is to be arranged with sufficiently long lengths of pipe both preceding and following the orifice, or other arrangements including straightening vanes, to assure no disturbance at the orifice place for the ratios of orifice to pipe diameters to be employed. Flanges between which the orifice plate is located and clamped are to be provided with pressure take-off lines connected to a manometer. This Annex 16 instrument indicates the pressure differential across the orifice plate and the reading is used in the flow calculation. A calibrated pressure gauge is to be installed in that portion of the meter pipe downstream of the orifice plate. This gauge indicates the flow pressure and the reading is also used in the flow calculation.
10.1.3.10.changed
From the recorded data and the known orifice coefficient of the flowmeter, the air-flow capacity of the pressure relief valve tested is to be calculated using the following formula: Fb Ft 0.1 h p Q Q= Where: Q = Flow capacity of pressure relief valve in m3/min. m 3/min. of air at 100 kPa absolute and 15 °C. Fb = Basic orifice factor of flowmeter at 100 kPa absolute and 15 °C. Ft = Flowing air temperature factor to convert recorded temperature to base of 15 °C. h = Differential pressure across orifice of meter in kPa. p = Flowing air pressure to pressure relief valve in kPa absolute (recorded gauge pressure plus recorded barometric pressure). 60 = Denominator to convert equation from m3/hour to m3/min.
10.2.9.changed
The test sample is to be connected to the outlet end of the piezometer. A manometer or calibrated pressure gauge of the retard type, which will permit readings in the range of 0 to 1,440 kPa is to be connected to a pressure take- Annex 16 off on the upstream side of the test sample to indicate the closing pressure. The connection is to be made using a length of rubber hose between the pressure gauge and the pressure take-off, with a valve installed at the gauge inlet to permit bleeding air from the system.
10.5.5.2.changed
15.changed
A non-metallic part containing liquid LPG shall comply with the leakage tests mentioned in paragraphs 5., 6. and 7. after having been submitted to a hydraulic pressure of 2.25 times the maximum operating pressure at a temperature of 120 °C during minimal 96 hours. Water or any other suitable hydraulic fluid may be used as a test medium. Annex 16
18.added
All components connecting the pressure relief valve and/or the pressure relief
device with the gaseous phase in the LPG container shall be tested using the
following procedure.
The tests shall be carried out on two samples, "a" and "b":
Sample "a" shall be aged according to paragraph 18.1.1. or 18.1.2.
The aged sample "a" shall undergo the vibration test according to
paragraph 18.2.
The virgin sample "b" shall be used as a reference for the flow test according
to paragraph 18.3.
18.1.added
Ageing tests on sample "a"
18.1.1.1.added
Disassemble, using instructions from the manufacturer, all non-metallic
materials from the component in contact with the liquid LPG.
18.1.1.2.added
Age the non-metallic materials using the test description of Annex 16,
paragraph 11.1.
18.1.1.3.added
Check compliance to Annex 16, paragraph 11.2.
18.1.1.4.added
Reassemble the aged non-metallic materials to the component using the
instructions from the manufacturer.
18.1.2.1.added
Expose the entire component to n-Pentane according to Annex 16,
paragraph 11.1.
18.1.2.2.added
Check compliance to Annex 16, paragraph 11.2.
18.2.added
Vibration test on aged sample "a"
18.2.1.added
Perform on the aged sample the vibration test in Annex 16, paragraph 10.5.,
procedures A or B. The sample shall comply with the test requirements in
Annex 16, paragraph 10.5., procedure A or B.
18.3.1.added
Perform for both samples the flow test according to paragraph 6.15.8.3. of this
Regulation.
18.3.2.added
Requirements:
Both aged and non-aged samples "a" and "b" shall comply with the flow
requirements as per paragraph 6.15.8.3. of this Regulation.
The non-metallic material of the samples "a" and "b" shall show no cracks,
deformation or any visual damage.
Annex 17changed
1.2.changed
Metallic components or parts which may come into contact with petrol shall have a permanent resistance against petrol. Metallic parts shall permanently be protected against corrosion (e.g. coating, surface finish, material mix) and fulfil the requirements of Annex 16, paragraph 12. Annex 20
2.1.changed
In order to verify compliance with paragraph 17.13.2.3. of this Regulation, a vehicle shall be tested as follows: Test procedure (a) Install the LPG equipment on the vehicle; (b) Fill up the LPG tank with at least 10 litres of fuel; (c) Set the fuel selection system in LPG mode; (d) Let the engine run at the lowest idling speed; (e) Switch over from LPG mode to petrol mode and vice versa; (f) Repeat the action (e) until the disablement of petrol mode becomes permanent. Test interpretation The criteria adopted for the interpretation of the test is as follows: Nsw < 0.16 * Vin / Vsw where: Nsw = the number of switch-over operations from LPG mode to petrol mode and vice versa until the disablement of petrol mode becomes permanent. Vsw = the volume of petrol flown into the LPG tank per switch- over switch-over operation as measured in paragraph 6.1. of Annex 14 to this Regulation. Vin = the initial volume of LPG according to paragraph 2.1.(b) of this annex above.